WorldWideScience

Sample records for multi-channel semicircular canal

  1. Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2003-01-01

    Heading Abstract.The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo (n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus (n=183) or symptoms unrelated to the labyrinth (n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence. (orig.)

  2. Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G A; Schmitz-Rode, T; Haage, P; Guenther, R W [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S [Department of Experimental Veterinarian Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2003-06-01

    Heading Abstract.The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo (n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus (n=183) or symptoms unrelated to the labyrinth (n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence. (orig.)

  3. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  4. Congenital aplasia of the semicircular canals.

    Science.gov (United States)

    Satar, Bulent; Mukherji, Suresh K; Telian, Steven A

    2003-05-01

    To describe the underrecognized inner ear malformation characterized by complete aplasia of the labyrinthine semicircular canals associated with a relatively well-formed cochlea, to investigate its relationship with known syndromic forms of hearing loss, and to hypothesize regarding the potential embryopathogenesis of this anomaly. A retrospective case review consisting of cases of sensorineural hearing loss with radiographic evidence demonstrating agenesis of the semicircular canals associated with a cochlea that was either morphologically normal or sufficiently well developed to accommodate the full insertion of a cochlear implant electrode. Cases were identified by computerized tomography findings that identified the anomaly under study. Departments of otolaryngology and radiology in a tertiary referral center, with a large cochlear implant program serving over 800 patients, more than half of whom are children. Fifteen patients with the anomaly under study were identified. Each patient underwent a complete otologic examination, audiometric studies, and high resolution computerized tomography of the temporal bone in axial and coronal planes. The bony morphology of the cochlea, round and oval windows, vestibule, semicircular canals, and vestibular aqueduct, and the course of the facial nerve were examined. Auditory findings and otologic treatment are presented. Of the 15 identified patients, 4 were nonsyndromic, 9 had CHARGE association (Coloboma of the eye, congenital Heart defects, choanal Atresia, mental and/or growth Retardation, Genital hypoplasia, and Ear anomalies and/or deafness), 1 met criteria for Noonan's syndrome, and one had features of both these syndromes. Although the cochlea was present in all cases, the cochlear morphology was usually abnormal in the CHARGE association patients. Of the 20 ears in the CHARGE subjects, only 3 ears (15%) were seen to have completely normal development of the cochlea in both the basal and upper turns. The others

  5. Computed tomography imaging for superior semicircular canal dehiscence syndrome

    International Nuclear Information System (INIS)

    Dobeli, Karen

    2006-01-01

    Superior semicircular canal dehiscence is a newly described syndrome of sound and/or pressure induced vertigo. Computed tomography (CT) imaging plays an important role in confirmation of a defect in the bone overlying the canal. A high resolution CT technique utilising 0.5 mm or thinner slices and multi-planar reconstructions parallel to the superior semicircular canal is required. Placement of a histogram over a suspected defect can assist CT diagnosis

  6. Gender and laterality in semicircular canal dehiscence syndrome.

    Science.gov (United States)

    Karimnejad, K; Czerny, M S; Lookabaugh, S; Lee, D J; Mikulec, A A

    2016-08-01

    To determine if there is gender or laterality predilection in patients with semicircular canal dehiscence syndrome. A multi-institutional chart review was performed to identify patients diagnosed with semicircular canal dehiscence between 2000 and 2015. A systematic literature search was conducted using PubMed to further identify patients with semicircular canal dehiscence. Age, gender and laterality data were collected. Statistical analysis was performed to evaluate for gender or laterality preponderance. A total of 682 patients with semicircular canal dehiscence were identified by literature and chart review. Mean age of diagnosis was 49.75 years (standard deviation = 15.33). Semicircular canal dehiscence was associated with a statistically significant female predominance (chi-square = 7.185, p = 0.007); the female-to-male ratio was 1.2 to 1. Left-sided semicircular canal dehiscence was most common, followed by right-sided then bilateral (chi-square = 23.457, p < 0.001). Semicircular canal dehiscence syndrome is most commonly left-sided and exhibits a female predominance. This may be secondary to morphological cerebral hemisphere asymmetries in both sexes and a predilection of women to seek more medical care than men.

  7. Tullio phenomenon in superior semicircular canal dehiscence syndrome.

    Science.gov (United States)

    Basura, Gregory J; Cronin, Scott J; Heidenreich, Katherine D

    2014-03-18

    Tullio phenomenon refers to eye movements induced by sound.(1) This unusual examination finding may be seen in superior semicircular canal dehiscence (SSCD) syndrome.(2) This disorder is due to absent bone over the superior semicircular canal (figure). Patients complain of dizziness triggered by loud sound, aural fullness, autophony, and pulsatile tinnitus. When Tullio phenomenon exists in SSCD syndrome, the patient develops a mixed vertical-torsional nystagmus in which the slow phase rotates up and away from the affected ear (video on the Neurology® Web site at Neurology.org). This pattern of nystagmus aligns in the plane of the dehiscent semicircular canal and is due to excitation of its afferent nerves.

  8. Temporal Bone Fracture Causing Superior Semicircular Canal Dehiscence

    Directory of Open Access Journals (Sweden)

    Kevin A. Peng

    2014-01-01

    Full Text Available Importance. Superior semicircular canal dehiscence (SCD is a third window lesion of the inner ear causing symptoms of vertigo, autophony, tinnitus, and hearing loss. A “two-hit” hypothesis has traditionally been proposed, whereby thinly developed bone overlying the superior canal is disrupted by a sudden change in intracranial pressure. Although the symptoms of SCD may be precipitated by head injury, no previous reports have described a temporal bone fracture directly causing SCD. Observations. Two patients sustained temporal bone fractures after closed head trauma, and developed unilateral otologic symptoms consistent with SCD. In each instance, computed tomography imaging revealed fractures extending through the bony roof of the superior semicircular canal. Conclusions and Relevance. Temporal bone fractures, which are largely treated nonoperatively, have not previously been reported to cause SCD. As it is a potentially treatable entity, SCD resulting from temporal bone fracture must be recognized as a possibility and diagnosed promptly if present.

  9. Partial absence of the posterior semicircular canal in Alagille syndrome: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Bernadette; Egelhoff, John; Benton, Corning [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati (United States); Goold, Amy [Tripler Army Medical Center, Family Practice, Honolulu, HI (United States)

    2006-09-15

    We report a case of bilateral partial absence of the posterior semicircular canals (with normal lateral semicircular canals) imaged with CT in a patient with Alagille syndrome. Similar histologic findings have been reported in the pathology literature. This association has been previously reported only for Waardenburg syndrome in the imaging literature. We review the imaging findings and embryology of the semicircular canals, and suggest that this abnormality is specific to patients with Alagille or Waardenburg syndrome. (orig.)

  10. Partial absence of the posterior semicircular canal in Alagille syndrome: CT findings

    International Nuclear Information System (INIS)

    Koch, Bernadette; Egelhoff, John; Benton, Corning; Goold, Amy

    2006-01-01

    We report a case of bilateral partial absence of the posterior semicircular canals (with normal lateral semicircular canals) imaged with CT in a patient with Alagille syndrome. Similar histologic findings have been reported in the pathology literature. This association has been previously reported only for Waardenburg syndrome in the imaging literature. We review the imaging findings and embryology of the semicircular canals, and suggest that this abnormality is specific to patients with Alagille or Waardenburg syndrome. (orig.)

  11. [Benign paroxysmal positional vertigo of the anterior semicircular canal: clinical aspects and treatment].

    Science.gov (United States)

    Lorin, P

    2005-01-01

    To describe the videonystagmographic characteristics and the treatment of the patients reached with a canalolithiasis or a cupulolithiasis of the anterior semicircular canal. Retrospective study concerning patients treated for a Benign Paroxysmal Positional Vertigo (BPPV) of the anterior semicircular canal. Each patient after analysis under videonystagmoscopy (VNS) and under videonystagmography (VNG) was treated by maneuvers. On 462 observations of typical BPPV 6 cases of VPPB of the anterior semicircular canal were treated concerning 5 patients (1.3%). The BPPV of the anterior semicircular canal are rare. We modified our method of diagnosis, and our therapeutic techniques could be validated with the help of the two-dimensional videonystagmography.

  12. CT and MR Imagings of Semicircular Canal Aplasia

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chung Hee; Hong, Hyun Sook; Yi, Beom Ha; Cha, Jang Gyu; Park, Seong Jin; Kim, Dae Ho; Lee, Hae Kyung; Kim, Shi Chan [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2009-07-15

    To evaluate the clinical, CT and MR imaging findings of semicircular canal (SCC) aplasia and to evaluate if a correlation exists between these findings and the associated anomalies or syndromes. This study retrospectively reviewed the CT and MRI findings of five patients with SCC aplasia. The CT and MR findings were analyzed for SCC, direction of facial nerve canal, cochlea, vestibule, oval or round window, middle ear ossicles, and internal auditory canal (IAC). The subjects included three boys and two girls ranging in age from one to 120 months (mean age; 51 months). Four of the subjects had the CHARGE syndrome, and one had the Goldenhar syndrome. Moreover, four subjects had sensorineural hearing loss and one had combined hearing loss. The course of the facial nerve canal was abnormal in all five cases. Moreover, trapped cochlea and dysplastic modiolus were each observed in one case. Four subjects had atresia of the oval window; whereas ankylosis of the ossicles was present in three subjects. IAC stenosis was present in one patient with the CHARGE syndrome. The aberrant course of the facial nerve canal, atresia of the oval window, and abnormal ossicles were frequently associated in patients with SCC aplasia. In addition, the Goldenhar and CHARGE syndromes were also commonly associated syndromes.

  13. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2004-01-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  14. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W. [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E. [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A. [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S. [Department of Experimental Veterinary Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2004-04-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  15. Semicircular canals circumvent Brownian Motion overload of mechanoreceptor hair cells

    DEFF Research Database (Denmark)

    Muller, Mees; Heeck, Kier; Elemans, Coen P H

    2016-01-01

    Vertebrate semicircular canals (SCC) first appeared in the vertebrates (i.e. ancestral fish) over 600 million years ago. In SCC the principal mechanoreceptors are hair cells, which as compared to cochlear hair cells are distinctly longer (70 vs. 7 μm), 10 times more compliant to bending (44 vs. 500...... nN/m), and have a 100-fold higher tip displacement threshold (hair cells where the bundle is approximated as a stiff, cylindrical elastic rod subject to friction and thermal agitation. Our models suggest that the above...... differences aid SCC hair cells in circumventing the masking effects of Brownian motion noise of about 70 nm, and thereby permit transduction of very low frequency (

  16. Gyroscopic stimulation of the semicircular canals during sensory deprivation.

    Science.gov (United States)

    Newsom, B. D.; Brady, J. F.; Stumm, J. E.

    1971-01-01

    A static object revolving at a constant velocity is stationary with respect to that environment. When the object is rotated outside the plane of spin, a gyroscopic or cross-coupled acceleration is produced orthogonal to the two planes of rotation. In this situation, a man feels himself moving in a direction other than that which his visual or proprioceptive sensors perceive. The conflict in spatial orientation is the cross-coupled acceleration imposed on the semicircular canals. This perceptual conflict and the thresholds involved were studied by partial isolation of the physiological stimuli through sensory deprivation. Subjects weighted to neutral buoyancy were submerged in 94 F water in the dark. The subjects were then rotated while being revolved about a displaced axis. Thresholds for detection of angular acceleration were higher than those reported in the literature for detection of acceleration of a single plane. This discrepancy may be attributable to the length of time the stimuli are imposed to each of the canals and the cupular response periods.

  17. A Comparison of Surgical Treatments for Superior Semicircular Canal Dehiscence: A Systematic Review

    NARCIS (Netherlands)

    Ziylan, F.; Kinaci, A.; Beynon, A.J.; Kunst, H.P.M.

    2017-01-01

    OBJECTIVE: We investigate the postoperative subjective and objective outcomes of different surgical treatments for superior semicircular canal dehiscence (SSCD): vestibular signs, auditory signs, vestibular evoked myogenic potential test, pure tone audiogram, speech audiogram, or

  18. Central Lesions With Selective Semicircular Canal Involvement Mimicking Bilateral Vestibulopathy

    Directory of Open Access Journals (Sweden)

    Luke Chen

    2018-04-01

    Full Text Available Bilateral vestibulopathy (BVP, which is due to peripheral lesions, may selectively involve certain semicircular canal (SCC. Recent eye movement recordings with search coil and video head impulse test (HIT have provided insight in central lesions that can cause bilateral and selective SCC deficit mimicking BVP. Since neurological signs or ocular motor deficits maybe subtle or absent, it is critical to recognize central lesions correctly since there is prognostic and treatment implication. Acute floccular lesions cause bilateral horizontal SCC (HC impairment while leaving vertical SCC function unaffected. Vestibular nuclear lesions affect bilateral HC and posterior SCC (PC function, but anterior SCC (AC function is spared. When both eyes are recorded, medial longitudinal fasciculus lesions cause horizontal dysconjugacy in HC function and catch-up saccades, as well as selective deficiency of PC over AC function. Combined peripheral and central lesions may be difficult to distinguish from BVP. Anterior inferior cerebellar artery stroke causes two types of deficits: 1. ipsilateral pan-SCC deficits and contralateral HC deficit and 2. bilateral HC deficit with vertical SCC sparing. Metabolic disorders such as Wernicke encephalopathy characteristically involve HC but not AC or PC function. Gaucher disease causes uniform loss of all SCC function but with minimal horizontal catch-up saccades. Genetic cerebellar ataxias and cerebellar-ataxia neuropathy vestibular areflexia syndrome typically do not spare AC function. While video HIT does not replace the gold-standard, search coil HIT, clinicians are now able to rapidly and accurately identify specific pattern of SCC deficits, which can aid differentiation of central lesions from BVP.

  19. Vestibulo-Ocular Reflex Abnormalities in Posterior Semicircular Canal Benign Paroxysmal Positional Vertigo: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Tayyebe Fallahnezhad

    2017-09-01

    Full Text Available Introduction: Benign paroxysmal positional vertigo (BPPV, involving the semicircular canals, is one of the most common diseases of the inner ear. The video head impulse test (vHIT is a new test that examines the function of the canals. This study aimed to investigate the vestibulo-ocular reflex (VOR gain, gain asymmetry and saccades after stimulating all six canals in patients definitively diagnosed with posterior semicircular canal BPPV (PSC-BPPV.   Materials and Methods: Twenty-nine unilateral PSC-BPPV patients with normal oculographic and caloric results were enrolled in this study. vHIT was performed on six canals, and VOR gain, gain asymmetry and saccades were measured.   Results: Sixteen (55.17% patients had abnormal posterior canal VOR gains in the ipsilesional ear. VOR gains in both horizontal canals were within normal limits. Superior canal VOR gains were mostly lower than normal and were not correlated to PSC abnormalities (P>0.05. No corrective saccades could be observed.   Conclusion: VOR gain in the direction of the posterior semicircular canal may be reduced in PSC-BPPV patients. Evaluation of PSC-VOR parameters could be beneficial, although superior canal measurements should be interpreted with caution.

  20. Turning semicircular canal function on its head: dinosaurs and a novel vestibular analysis.

    Science.gov (United States)

    Georgi, Justin A; Sipla, Justin S; Forster, Catherine A

    2013-01-01

    Previous investigations have correlated vestibular function to locomotion in vertebrates by scaling semicircular duct radius of curvature to body mass. However, this method fails to discriminate bipedal from quadrupedal non-avian dinosaurs. Because they exhibit a broad range of relative head sizes, we use dinosaurs to test the hypothesis that semicircular ducts scale more closely with head size. Comparing the area enclosed by each semicircular canal to estimated body mass and to two different measures of head size, skull length and estimated head mass, reveals significant patterns that corroborate a connection between physical parameters of the head and semicircular canal morphology. Head mass more strongly correlates with anterior semicircular canal size than does body mass and statistically separates bipedal from quadrupedal taxa, with bipeds exhibiting relatively larger canals. This morphologic dichotomy likely reflects adaptations of the vestibular system to stability demands associated with terrestrial locomotion on two, versus four, feet. This new method has implications for reinterpreting previous studies and informing future studies on the connection between locomotion type and vestibular function.

  1. Turning semicircular canal function on its head: dinosaurs and a novel vestibular analysis.

    Directory of Open Access Journals (Sweden)

    Justin A Georgi

    Full Text Available Previous investigations have correlated vestibular function to locomotion in vertebrates by scaling semicircular duct radius of curvature to body mass. However, this method fails to discriminate bipedal from quadrupedal non-avian dinosaurs. Because they exhibit a broad range of relative head sizes, we use dinosaurs to test the hypothesis that semicircular ducts scale more closely with head size. Comparing the area enclosed by each semicircular canal to estimated body mass and to two different measures of head size, skull length and estimated head mass, reveals significant patterns that corroborate a connection between physical parameters of the head and semicircular canal morphology. Head mass more strongly correlates with anterior semicircular canal size than does body mass and statistically separates bipedal from quadrupedal taxa, with bipeds exhibiting relatively larger canals. This morphologic dichotomy likely reflects adaptations of the vestibular system to stability demands associated with terrestrial locomotion on two, versus four, feet. This new method has implications for reinterpreting previous studies and informing future studies on the connection between locomotion type and vestibular function.

  2. Semicircular canals in Anolis lizards: ecomorphological convergence and ecomorph affinities of fossil species.

    Science.gov (United States)

    Dickson, Blake V; Sherratt, Emma; Losos, Jonathan B; Pierce, Stephanie E

    2017-10-01

    Anoli s lizards are a model system for the study of adaptive radiation and convergent evolution. Greater Antillean anoles have repeatedly evolved six similar forms or ecomorphs: crown-giant, grass-bush, twig, trunk, trunk-crown and trunk-ground. Members of each ecomorph category possess a specific set of morphological, ecological and behavioural characteristics which have been acquired convergently. Here we test whether the semicircular canal system-the organ of balance during movement-is also convergent among ecomorphs, reflecting the shared sensory requirements of their ecological niches. As semicircular canal shape has been shown to reflect different locomotor strategies, we hypothesized that each Anolis ecomorph would have a unique canal morphology. Using three-dimensional semilandmarks and geometric morphometrics, semicircular canal shape was characterized in 41 Anolis species from the Greater Antilles and the relationship between canal shape and ecomorph grouping, phylogenetic history, size, head dimensions, and perch characteristics was assessed. Further, canal morphology of modern species was used to predict the ecomorph affinity of five fossil anoles from the Miocene of the Dominican Republic. Of the covariates tested, our study recovered ecomorph as the single-most important covariate of canal morphology in modern taxa; although phylogenetic history, size, and head dimensions also showed a small, yet significant correlation with shape. Surprisingly, perch characteristics were not found to be significant covariates of canal shape, even though they are important habitat variables. Using posterior probabilities, we found that the fossil anoles have different semicircular canals shapes to modern ecomorph groupings implying extinct anoles may have been interacting with their Miocene environment in different ways to modern Anolis species.

  3. Semicircular canals in Anolis lizards: ecomorphological convergence and ecomorph affinities of fossil species

    Science.gov (United States)

    Dickson, Blake V.; Sherratt, Emma; Losos, Jonathan B.; Pierce, Stephanie E.

    2017-10-01

    Anolis lizards are a model system for the study of adaptive radiation and convergent evolution. Greater Antillean anoles have repeatedly evolved six similar forms or ecomorphs: crown-giant, grass-bush, twig, trunk, trunk-crown and trunk-ground. Members of each ecomorph category possess a specific set of morphological, ecological and behavioural characteristics which have been acquired convergently. Here we test whether the semicircular canal system-the organ of balance during movement-is also convergent among ecomorphs, reflecting the shared sensory requirements of their ecological niches. As semicircular canal shape has been shown to reflect different locomotor strategies, we hypothesized that each Anolis ecomorph would have a unique canal morphology. Using three-dimensional semilandmarks and geometric morphometrics, semicircular canal shape was characterized in 41 Anolis species from the Greater Antilles and the relationship between canal shape and ecomorph grouping, phylogenetic history, size, head dimensions, and perch characteristics was assessed. Further, canal morphology of modern species was used to predict the ecomorph affinity of five fossil anoles from the Miocene of the Dominican Republic. Of the covariates tested, our study recovered ecomorph as the single-most important covariate of canal morphology in modern taxa; although phylogenetic history, size, and head dimensions also showed a small, yet significant correlation with shape. Surprisingly, perch characteristics were not found to be significant covariates of canal shape, even though they are important habitat variables. Using posterior probabilities, we found that the fossil anoles have different semicircular canals shapes to modern ecomorph groupings implying extinct anoles may have been interacting with their Miocene environment in different ways to modern Anolis species.

  4. Association between type 1 diabetes mellitus and deposits in the semicircular canals.

    Science.gov (United States)

    Yoda, Shigetoshi; Cureoglu, Sebahattin; Yildirim-Baylan, Muzeyyen; Morita, Norimasa; Fukushima, Hisaki; Harada, Tamotsu; Paparella, Michael M

    2011-09-01

    To compare the prevalence of cupular and free-floating deposits in the semicircular canals between temporal bones of type 1 diabetes mellitus patients and normal controls. Case-control histopathologic human temporal bone study. Otopathology laboratory in a tertiary academic medical center. Twenty-eight temporal bones from 14 patients with type 1 diabetes mellitus and 56 normal temporal bones from 28 age-matched individuals were histopathologically examined. The cupula and lumina of the semicircular canals were examined for evidence of deposits. The prevalence of cupular and free-floating deposits in the lateral and posterior semicircular canals was significantly higher in type 1 diabetes mellitus patients compared with normal temporal bones (lateral, cupular deposits, odds ratio [OR], 5.47; 95% confidence interval [CI], 1.43 to 21.02; free-floating deposits, OR, 8.25; 95% CI, 2.42 to 27.85; posterior, cupular deposits, OR, 41.73; 95% CI, 5.96 to 275.50; free-floating deposits, OR, 7.44; 95% CI, 1.91 to 28.53). The prevalence of these deposits was associated with the duration of disease rather than with aging. The findings suggest that type 1 diabetes mellitus is associated with cupular and free-floating deposits in the semicircular canals. The patients with type 1 diabetes mellitus with a longer duration of disease have an increased probability of suffering from benign paroxysmal positional vertigo.

  5. [The features of high and low-frequency function of horizontal, semicircular canal in Meniere's disease].

    Science.gov (United States)

    Chen, Ying; Zhao, Zhongxin; Zhuang, Jianhua; Xie, Xuewei; Jin, Zhe; Li, Fei

    2015-05-01

    To analyze the feature of horizontal semicircular canal function at high and low-frequencies in Meniere's disease. Thirty patients suffering from unilateral Meniere's disease were included in the research from 2013 June to 2014 June. Caloric test and video head impulse test were performed to evaluate the high low-frequency function of horizontal semicircular canal. these patients were devided by the severity of unilateral weakness in caloric test. The gain value in video head impulse test, which reflects the high-frequency function of semicircular canal, were not different between the normal and mild abnormal group (P > 0.05), but were obviously different between the normal and mild-severe abnormal group, slight abnormal and mild-severe abnormal group (P frequency function of both side, has no difference between three groups (P > 0.05). A part of Meniere's disease may have normal high, low-frequency function of horizontal semicircular canal. As patient suffering slight injury of low-frequency function, the high-frequency function keeps normal. As the injury of low-frequency function become mildly to severely, the damage of high-frequency function appears, but the symmetry still keeps balance.

  6. Quantification of hearing loss in patients with posterior semicircular canal dehiscence.

    Science.gov (United States)

    Bear, Zachary W; McEvoy, Timothy P; Mikulec, Anthony A

    2015-01-01

    Patients with posterior semicircular canal dehiscence (PSCD) have low frequency conductive hearing loss similar to patients with superior semicircular canal dehiscence (SSCD) secondary to a pathologic third window. PSCD can result in conductive hearing loss, but the magnitude of this hearing loss remains to be quantified. Patients with SSCD have been shown to have low frequency conductive hearing loss. The underlying pathophysiology of hearing loss from PSCD and SSCD is similar and related to a pathologic third window. A PubMed search was completed for a meta-analysis of patients with PSCD. Articles with quality audiograms were obtained. Air conduction thresholds for ears with posterior semicircular canal dehiscence were compared to the opposite ear as well as normal control data. Eight articles with 21 patients with PSCD and quality audiograms were included. Two patients had bilateral PSCD and one of those was excluded because hearing thresholds were at the limit of the audiometer. Patients with posterior semicircular canal dehiscence have statistically significant lower air conduction thresholds in frequencies at and below 2000 Hz.

  7. Síndrome de Deiscência de Canal Semicircular Superior Superior Canal Dehiscence Syndrome

    Directory of Open Access Journals (Sweden)

    Suzane da Cunha Ferreira

    2006-06-01

    Full Text Available A Síndrome de Deiscência de Canal Semicircular Superior (SDCSS, primeiramente descrita em 1998 por Minor et al., caracteriza-se por vertigem associada à presença de nistagmo, relacionados à exposição a estímulos sonoros intensos ou a modificações de pressão dentro da orelha média ou intracraniana. Disacusia, em sua maioria de padrão condutivo à audiometria tonal, também pode estar presente. Nesta revisão da literatura objetivou-se abordar a SDCSS, com seus principais sinais e sintomas, achados diagnósticos e tratamento, assim como enfatizar a importância de sua inclusão dentre as causas de vertigem, visto tratar-se de acometimento ainda pouco conhecido até mesmo entre especialistas. O diagnóstico correto, além de possibilitar seu tratamento, impede que abordagens diagnósticas e terapêuticas inapropriadas sejam realizadas.The Superior Canal Dehiscence Syndrome (SCDS was first reported by Minor at. Al. (1998, and has been characterized by vertigo and vertical-torsional eye movements related to loud sounds or stimuli that change middle ear or intracranial pressure. Hearing loss, for the most part with conductive patterns on audiometry, may be present in this syndrome. We performed a literature survey in order to to present symptoms, signs, diagnostic and therapeutic approaches to the SCDS, also aiming at stressing the great importance of including this syndrome among the tractable cause of vertigo. We should emphasize that this is a recent issue, still unknown by some specialists. The Correct SCDS diagnosis, besides enabling patient treatment, precludes misdiagnosis and inadequate therapeutic approaches.

  8. Persistent positional nystagmus: a case of superior semicircular canal benign paroxysmal positional vertigo?

    Science.gov (United States)

    Heidenreich, Katherine D; Kerber, Kevin A; Carender, Wendy J; Basura, Gregory J; Telian, Steven A

    2011-08-01

    Involvement of the superior semicircular canal (SSC) in benign paroxysmal positional vertigo (BPPV) is rare. SSC BPPV is distinguished from the more common posterior semicircular canal (PSC) variant by the pattern of nystagmus triggered by the Dix-Hallpike position: down-beating torsional nystagmus in SSC BPPV versus up-beating torsional nystagmus in PSC BPPV. SSC BPPV may be readily treated at the bedside, which is a key component in excluding central causes of down-beating nystagmus. We present an unusual video case report believed to represent refractory SSC BPPV based on the pattern of nystagmus and the absence of any other central signs. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  9. Changes of ampulla pressure in the semicircular canal of pigeons by caloric stimulation

    Science.gov (United States)

    Wada, Yoshiro; Suzuki, Hiroyuki; Watanabe, Satoru

    Still now several hypotheses about the mechanisms of the caloric nystagmus have been in conclusive. In this study we confirmed the convection effect and the volume change effect of the endolymph in horizontal semicircular canal following the caloric stimulation using pigeons ( Columba livia). Although the direction of the caloric nystagmus depended on the head position and the stimulus site of calorization, the caloric nystagmus disappeared after plugging of horizontal semicircular canal. On the other hand, the ampulla pressure increased by cold calorization and decreased by hot calorization and these pressure changes had no relation to the head position. These results show that the main role of the mechanisms of the caloric nystagmus under 1G is the convection effect but the volume change effect may act on the caloric nystagmus not only under 1G but also under microgravity.

  10. Utricular paresis and semicircular canal hyperactivity: a distinct otolith syndrome.

    Science.gov (United States)

    Angeli, Simon I; Snapp, Hillary; Velandia, Sandra; Morgenstein, Kari

    2015-04-01

    Although combined utricular and canal paresis has been described previously, this is the first report of canal hyperactivity associated with utricular hypofunction. Unsteadiness and swaying were the most common symptoms, and patients with shorter duration of symptoms also had positional vertigo. We propose that this syndrome is a variant of utricular dysfunction and should be considered in the differential diagnosis of peripheral vestibular disorders. To describe a syndrome of instability associated with utricular dysfunction and hyperactive caloric responses. The study comprised 11 consecutive patients exhibiting abnormalities of the eccentric subjective visual vertical test (e-SVV) and high responses during the caloric test of the videonystagmography (VNG). We carried out a review of symptoms, physical examination, and vestibular tests. There was no gender predilection or obvious etiology. The patients' main complaint included instability with linear symptoms (i.e., tilting, rocking, and swaying), with positional vertigo as a secondary symptom. Oculomotor testing, visual fixation index, and brain MRI were normal, excluding a central nervous system disorder. VNG was essentially normal except for hyperactive responses during the caloric testing in all patients. Abnormal e-SVV was found in 10 patients unilaterally and bilaterally in 1 patient. Abnormal oVEMP was found in seven of seven patients, further supporting a utricular site of lesion.

  11. Functional recovery of anterior semicircular canal afferents following hair cell regeneration in birds

    Science.gov (United States)

    Boyle, Richard; Highstein, Stephen M.; Carey, John P.; Xu, Jinping

    2002-01-01

    Streptomycin sulfate (1.2 g/kg i.m.) was administered for 5 consecutive days to 5-7-day-old white Leghorn chicks; this causes damage to semicircular canal hair cells that ultimately regenerate to reform the sensory epithelium. During the recovery period, electrophysiological recordings were taken sequentially from anterior semicircular canal primary afferents using an indentation stimulus of the canal that has been shown to mimic rotational stimulation. Chicks were assigned to an early (14-18 days; n = 8), intermediate (28-34 days; n = 5), and late (38-58 days; n = 4) period based on days after treatment. Seven untreated chicks, 15-67 days old, provided control data. An absence of background and indent-induced discharge was the prominent feature of afferents in the early period: only "silent" afferents were encountered in 5/8 experiments. In several of these chicks, fascicles of afferent fibers were seen extending up to the epithelium that was void of hair cells, and intra- and extracellular biocytin labeling revealed afferent processes penetrating into the supporting cell layer of the crista. In 3/8 chicks 74 afferents could be characterized, and they significantly differed from controls (n = 130) by having a lower discharge rate and a negligible response to canal stimulation. In the intermediate period there was considerable variability in discharge properties of 121 afferents, but as a whole the number of "silent" fibers in the canal nerve diminished, the background rate increased, and a response to canal stimulation detected. Individually biocytin-labeled afferents had normal-appearing terminal specializations in the sensory epithelium by 28 days poststreptomycin. In the late period, afferents (n = 58) remained significantly different from controls in background discharge properties and response gain. The evidence suggests that a considerable amount of variability exists between chicks in the return of vestibular afferent function following ototoxic injury and

  12. Vestibular Dysfunction in Wernicke’s Encephalopathy: Predominant Impairment of the Horizontal Semicircular Canals

    Directory of Open Access Journals (Sweden)

    Seung-Han Lee

    2018-03-01

    Full Text Available BackgroundWernicke’s encephalopathy (WE, a metabolic disorder due to thiamine deficiency, manifests with various neurological symptoms and signs. It has been known as a cause of vestibular dysfunction. Preliminary reports have proposed predominant involvement of the horizontal semicircular canals (HSCs.ObjectiveTo better characterize the pattern of vestibular impairment in patients with WE using quantitative video head-impulse testing and to review the literature regarding this topic.MethodFrom January 2014 to December 2016, we retrospectively enrolled five cases of WE that received quantitative video-head-impulse testing (vHIT. We retrieved the clinical features from the medical records and reviewed quantitative head-impulse testing (qHIT and caloric irrigation. Based on the gain and the number of corrective saccades, the function (normal vs. impaired of each semicircular canal was rated. In addition, we conducted a MEDLINE and EMBASE search to identify other published cases of WE that had received qHIT. Neuro-otologic and neuro-ophthalmologic findings and vestibular testing results were extracted.ResultsA total of 17 patients (own series = 5; published cases = 12 aged 54.6 ± 11 years were included. Key neurologic findings were ataxia of stance and gait (13/13, 100%, spontaneous nystagmus (7/14, 50%, gaze-evoked nystagmus (GEN (17/17, 100%, positive bedside head-impulse testing for the horizontal canals (16/17, 94%, and memory impairment and mental changes (6/11, 54.5%. Regarding vestibular testing, qHIT (either video based or search-coil based documented selective bilateral horizontal canal dysfunction with normal or minimal vertical canal impairment (14/14, 100%. On caloric irrigation, bilateral horizontal canal paresis was noted in most cases (10/11, 91%.ConclusionIn WE, signs of both peripheral and central vestibular dysfunction (i.e., GEN, ataxia of stance and gait, abnormal head-impulse testing were common. Selective or

  13. Histamine H1 receptors are expressed in mouse and frog semicircular canal sensory epithelia.

    Science.gov (United States)

    Botta, Laura; Tritto, Simona; Perin, Paola; Laforenza, Umberto; Gastaldi, Giulia; Zampini, Valeria; Zucca, Gianpiero; Valli, Stefano; Masetto, Sergio; Valli, Paolo

    2008-03-05

    Histamine-related drugs are commonly used in the treatment of vertigo and related vestibular disorders. Their site and mechanism of action, however, are still poorly understood. To increase our knowledge of the histaminergic system in the vestibular organs, we have investigated the expression of H1 and H3 histamine receptors in the frog and mouse semicircular canal sensory epithelia. Analysis was performed by mRNA reverse transcriptase-PCR, immunoblotting and immunocytochemistry experiments. Our data show that both frog and mouse vestibular epithelia express H1 receptors. Conversely no clear evidence for H3 receptors expression was found.

  14. Development of conductive hearing loss due to posterior semicircular canal dehiscence.

    Science.gov (United States)

    Kubota, Marie; Kubo, Kazuhiko; Yasui, Tetsuro; Matsumoto, Nozomu; Komune, Shizuo

    2015-06-01

    We herein report a case of posterior semicircular canal dehiscence (SCD) syndrome who had been audiologically followed up for eight years. The patient originally had sensorineural hearing loss. The audiogram had gradually transformed to pure conductive hearing loss. The posterior SCD was identified in CT scan. The reported case showed the possibility to distinguish the mechanism at play underlying the typical conductive hearing loss in SCD patients by tracing the transition of the hearing loss pattern. This information is of much help to predict the hearing outcomes if surgical intervention were chosen for the treatment. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Incidence of dehiscence of the bony roof of the superior semicircular canal by CT imaging

    International Nuclear Information System (INIS)

    Watanabe, Akira

    2003-01-01

    Dehiscence of the bony roof of the superior semicircular canal (SSCC) is rare, but it has been recognized by otologists since Minor et al first described superior canal dehiscence syndrome (SCDS). In this study, dehiscence of the bony roof of SSCC was incidentally detected in three patients with benign paroxysmal positional vertigo out of 49 serial patients with vertigo and dizziness by multi-slice computed tomography. Although detection of dehiscence of the SSCC by ultra-high-resolution CT imaging of the temporal bones has been required for a diagnosis of SCDS, this study showed that dehiscence of the bony roof of the SSCC can be an incidental finding and therefore is not specific for SCDS. (author)

  16. The Human Semicircular Canals Orientation Is More Similar to the Bonobos than to the Chimpanzees

    Science.gov (United States)

    El Khoury, Marwan; Braga, José; Dumoncel, Jean; Nancy, Javotte; Esclassan, Remi; Vaysse, Frederic

    2014-01-01

    For some traits, the human genome is more closely related to either the bonobo or the chimpanzee genome than they are to each other. Therefore, it becomes crucial to understand whether and how morphostructural differences between humans, chimpanzees and bonobos reflect the well known phylogeny. Here we comparatively investigated intra and extra labyrinthine semicircular canals orientation using 260 computed tomography scans of extant humans (Homo sapiens), bonobos (Pan paniscus) and chimpanzees (Pan troglodytes). Humans and bonobos proved more similarities between themselves than with chimpanzees. This finding did not fit with the well established chimpanzee – bonobo monophyly. One hypothesis was convergent evolution in which bonobos and humans produce independently similar phenotypes possibly in response to similar selective pressures that may be associated with postural adaptations. Another possibility was convergence following a “random walk” (Brownian motion) evolutionary model. A more parsimonious explanation was that the bonobo-human labyrinthine shared morphology more closely retained the ancestral condition with chimpanzees being subsequently derived. Finally, these results might be a consequence of genetic diversity and incomplete lineage sorting. The remarkable symmetry of the Semicircular Canals was the second major finding of this article with possible applications in taphonomy. It has the potential to investigate altered fossils, inferring the probability of post-mortem deformation which can lead to difficulties in understanding taxonomic variation, phylogenetic relationships, and functional morphology. PMID:24710502

  17. The human semicircular canals orientation is more similar to the bonobos than to the chimpanzees.

    Directory of Open Access Journals (Sweden)

    Marwan El Khoury

    Full Text Available For some traits, the human genome is more closely related to either the bonobo or the chimpanzee genome than they are to each other. Therefore, it becomes crucial to understand whether and how morphostructural differences between humans, chimpanzees and bonobos reflect the well known phylogeny. Here we comparatively investigated intra and extra labyrinthine semicircular canals orientation using 260 computed tomography scans of extant humans (Homo sapiens, bonobos (Pan paniscus and chimpanzees (Pan troglodytes. Humans and bonobos proved more similarities between themselves than with chimpanzees. This finding did not fit with the well established chimpanzee - bonobo monophyly. One hypothesis was convergent evolution in which bonobos and humans produce independently similar phenotypes possibly in response to similar selective pressures that may be associated with postural adaptations. Another possibility was convergence following a "random walk" (Brownian motion evolutionary model. A more parsimonious explanation was that the bonobo-human labyrinthine shared morphology more closely retained the ancestral condition with chimpanzees being subsequently derived. Finally, these results might be a consequence of genetic diversity and incomplete lineage sorting. The remarkable symmetry of the Semicircular Canals was the second major finding of this article with possible applications in taphonomy. It has the potential to investigate altered fossils, inferring the probability of post-mortem deformation which can lead to difficulties in understanding taxonomic variation, phylogenetic relationships, and functional morphology.

  18. Preserved otolith organ function in caspase-3-deficient mice with impaired horizontal semicircular canal function.

    Science.gov (United States)

    Armstrong, Patrick A; Wood, Scott J; Shimizu, Naoki; Kuster, Kael; Perachio, Adrian; Makishima, Tomoko

    2015-06-01

    Genetically engineered mice are valuable models for elucidation of auditory and vestibular pathology. Our goal was to establish a comprehensive vestibular function testing system in mice using: (1) horizontal angular vestibulo-ocular reflex (hVOR) to evaluate semicircular canal function and (2) otolith-ocular reflex (OOR) to evaluate otolith organ function and to validate the system by characterizing mice with vestibular dysfunction. We used pseudo off-vertical axis rotation to induce an otolith-only stimulus using a custom-made centrifuge. For the OOR, horizontal slow-phase eye velocity and vertical eye position were evaluated as a function of acceleration. Using this system, we characterized hVOR and OOR in the caspase-3 (Casp3) mutant mice. Casp3 (-/-) mice had severely impaired hVOR gain, while Casp3 (+/-) mice had an intermediate response compared to WT mice. Evaluation of OOR revealed that at low-to-mid frequencies and stimulus intensity, Casp3 mutants and WT mice had similar responses. At higher frequencies and stimulus intensity, the Casp3 mutants displayed mildly reduced otolith organ-related responses. These findings suggest that the Casp3 gene is important for the proper function of the semicircular canals but less important for the otolith organ function.

  19. Preserved otolith organ function in caspase-3 deficient mice with impaired horizontal semicircular canal function

    Science.gov (United States)

    Armstrong, Patrick A; Wood, Scott J; Shimizu, Naoki; Kuster, Kael; Perachio, Adrian; Makishima, Tomoko

    2015-01-01

    Genetically engineered mice are valuable models for elucidation of auditory and vestibular pathology. Our goal was to establish a comprehensive vestibular function testing system in mice using: 1) horizontal angular vestibular-ocular reflex (hVOR) to evaluate semicircular canal function, and 2) otolith-ocular reflex (OOR) to evaluate otolith organ function, and to validate the system by characterizing mice with vestibular dysfunction. We used pseudo-off vertical axis rotation (pOVAR) to induce an otolith-only stimulus using a custom-made centrifuge. For the OOR, horizontal slow phase eye velocity (HEV) and vertical eye position (VEP) was evaluated as a function of acceleration. Using this system, we characterized hVOR and OOR in the caspase-3 (Casp3) mutant mice. Casp3 −/− mice had severely impaired hVOR gain, while Casp3 +/− mice had an intermediate response compared to WT mice. Evaluation of OOR revealed that at low to mid frequencies and stimulus intensity, Casp3 mutants and WT mice had similar responses. At higher frequencies and stimulus intensity, the Casp3 mutants displayed mildly reduced otolith organ related responses. These findings suggest that the Casp3 gene is important for the proper function of the semicircular canals but less important for the otolith organ function. PMID:25827332

  20. Mondini-like malformation mimicking otosclerosis and superior semicircular canal dehiscence.

    Science.gov (United States)

    Karlberg, M; Annertz, M; Magnusson, M

    2006-05-01

    In 2003, it was reported that superior semicircular canal dehiscence can mimic otosclerosis because of low-frequency bone conduction hearing gain and dissipation of air-conducted acoustic energy through the dehiscence. We report the case of a 17-year-old girl with left-sided combined hearing loss thought to be due to otosclerosis. Bone conduction thresholds were -10 dB at 250 and 500 Hz and she had a 40 dB air-bone gap at 250 Hz. When a tuning fork was placed at her ankle she heard it in her left ear. Acoustic reflexes and vestibular evoked myogenic potentials could be elicited bilaterally. Imaging of the temporal bones showed no otosclerosis, superior semicircular canal dehiscence or large vestibular aqueduct, but a left-sided, Mondini-like dysplasia of the cochlea with a modiolar deficiency could be seen. Mondini-like cochlear dysplasia should be added to the causes of inner-ear conductive hearing loss.

  1. [Objective characteristics of nystagmus in horizontal semicircular canal benign paroxysmal positional vertigo].

    Science.gov (United States)

    Chen, Fei-yun; Chen, Tai-sheng; Wen, Chao; Li, Shan-shan; Lin, Peng; Zhao, Hui; Liu, Qiang

    2013-08-01

    To discuss the objective characteristics and mechanism of nystagmus direction, intensity and time in horizontal semicircular canal benign paroxysmal positional vertigo (HSC-BPPV) . A total of 233 patients with HSC-BPPV, whereas 179 horizontal semicircular canalithasis (HSC-Can) and 54 horizontal semicircular cupulolithiasis (HSC-Cup) were involved respectively. The induced nystagmus in roll tests recorded by video-nystagmograph(VNG) , whose direction, intensity and time characteristics were compared in various BPPV. Horizontal nystagmus was both induced by turning left or right in HSC-BPPV roll tests. The direction of the induced nystagmus was the same with turning in HSC-Can. The latency, duration time and intensity ([AKx(-)D] ± s) turning to lesion and normal side were (1.922 ± 1.501)s and (1.447 ± 0.855)s, (25.620 ± 10.409)s, and (22.110 ± 10.931)s, (56.441 ± 33.168)°/s and (24.239 ± 13.892) °/s in HSC-Can. The latency, duration time and intensity turning to lesion side were larger than normal side (t = 3.715, 15.219 and 4.070, P 0.05). The induced nystagmus intensity of head to two sides in roll tests for HSC-BPPV both follow Ewald's law, and the ratio between stronger and weaker are both 2: 1. These nystagmus parameters of VNG in roll tests are an objective guideline for BPPV diagnosis.

  2. Anterior semicircular canal benign paroxysmal positional vertigo and positional downbeating nystagmus.

    Science.gov (United States)

    Lopez-Escamez, Jose A; Molina, Maria I; Gamiz, Maria J

    2006-01-01

    The aim of this study was to describe the clinical features and video-oculographic findings in patients with anterior semicircular canal benign paroxysmal positional vertigo (BPPV). This is a prospective case series. The study was set at an outpatient clinic in a general hospital. Fourteen individuals with symptoms of BPPV and positional downbeating nystagmus (pDBN) were included in the study. The diagnosis was based on a history of brief episodes of vertigo and the presence of pDBN confirmed in the video-oculographic examination during Dix-Hallpike test (DH) or head-hanging maneuver. Patients were treated by particle repositioning maneuver and the effectiveness was evaluated at 7, 30, and 180 days posttreatment. The treatment was repeated up to 4 times if pDBN was persistent. The main outcome measure is the number of patients without pDBN at 30 and 180 days. Video-oculography showed a predominant pDBN in response to DH. Of the 14 patients, 7 had arterial hypertension, and 5 of 14 cases presented abnormalities on the caloric test. Horizontal spontaneous nystagmus was found in 3 of 14 individuals. Positional nystagmus at different positional test was observed in 5 of 14 individuals, suggesting the involvement of several canals. Of the 14 patients, 10 (71%) did not present vertigo, and the positional tests were negative at 30 days. However, 3 cases presented a positive DH with persistence of BPPV episodes and pDBN at 30 days, and another developed a contralateral posterior canal affectation. One of the patients maintained a persistent pDBN at 180 days despite the repeated maneuvers. Video-oculography demonstrates that anterior canal BPPV is characterized by a predominant downbeating nystagmus in response to DH. These individuals may show alterations in the vestibular caloric, and they can have multicanal affectation.

  3. The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures

    Science.gov (United States)

    Nakajima, Hideko Heidi; Pisano, Dominic V.; Merchant, Saumil N.; Rosowski, John J.

    2011-11-01

    Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability is not fully understood. We use intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Simultaneous measurement of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) quantifies the complex differential pressure across the cochlear partition, the stimulus that excites the partition. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure are measured simultaneously for various sizes of SCD followed by SCD patching. At low frequencies (<600 Hz) our results show that SCD decreases the pressure in both SV and ST, as well as differential pressure, and these effects become more pronounced as dehiscence size is increased. For frequencies above 1 kHz, the smallest pinpoint dehiscence can have the larger effect on the differential pressure in some ears. These effects due to SCD are reversible by patching the dehiscence.

  4. Vestibular ablation and a semicircular canal prosthesis affect postural stability during head turns

    Science.gov (United States)

    Thompson, Lara A.; Haburcakova, Csilla; Lewis, Richard F.

    2016-01-01

    In our study, we examined postural stability during head turns for two rhesus monkeys: one, single animal study contrasted normal and mild bilateral vestibular ablation and a second animal study contrasted severe bilateral vestibular ablation with and without prosthetic stimulation. The monkeys freely stood, unrestrained on a balance platform and made voluntary head turns between visual targets. To quantify each animals’ posture, motions of the head and trunk, as well as torque about the body’s center-of-mass, were measured. In the mildly ablated animal, we observed less foretrunk sway in comparison to the normal state. When the canal prosthesis provided electric stimulation to the severely ablated animal, it showed a decrease in trunk sway during head turns. Because the rhesus monkey with severe bilateral vestibular loss exhibited a decrease in trunk sway when receiving vestibular prosthetic stimulation, we propose that the prosthetic electrical stimulation partially restored head velocity information. Our results provide an indication that a semicircular canal prosthesis may be an effective way to improve postural stability in patients with severe peripheral vestibular dysfunction. PMID:27405997

  5. The Density Difference of Cupula and Endolymph Changes the Mechanics of Semicircular Canals

    Science.gov (United States)

    Kondrachuk, Alexander V.; Boyle, Richard D.

    2011-11-01

    A precise balance of cupula and endolymph densities is key to the proper sensing of angular acceleration by the semicircular canals (SC). Estimates show that a density difference of cupula and endolymph (DD) as small as 10 - 4 g/cm3 is sufficient to make the SC sensitive to gravity and centrifugal forces provided they are comparable with gravity. As a result this might cause vestibular disorders. There are conditions under which the DD may even exceed this value. One of them is a change of intra-labyrinth pressure (IP) that may take place during a spaceflight. Here, the effect of DD on SC dynamics is considered using a simplified one-dimensional toroidal mathematical model of a canal for rotation with constant or harmonically oscillating angular velocities. The DD results in: dependence of cupula dynamics on orientation of both the gravity vector relative to the SC plane and the axis of rotation, as well as on the distance between the axis of rotation and the center of SC; shift of the cupula to a new position of equilibrium that depends on both the gravity vector and the parameters of head rotation; and onset of cupula oscillations with multiple frequencies under harmonic stimulation. The DD effect may be important under conditions of artificial gravity where the directions of centrifugal forces, the values of which are comparable with Earth's gravity, the orientations of the axis of rotation of a space station, and the axes of the SCs change during movements of the individuals and their habitat.

  6. Assessment of the anatomical relationship between the arcuate eminence and superior semicircular canal by computed tomography

    International Nuclear Information System (INIS)

    Seo, Yoshinobu; Ito, Tamio; Sasaki, Takehiko; Nakagawara, Jyoji; Nakamura, Hirohiko

    2007-01-01

    The anatomical relationship between the arcuate eminence (AE) and the superior semicircular canal (SSC) was examined by computed tomography (CT) in 52 petrous bones of 26 patients. After acquiring volume data by multidetector CT, 1-mm thick oblique bone window images perpendicular to the SSC were obtained from the axial images. The distances between the AE and the SSC, and the SSC and the superior surface of the petrous bone were measured. The AE corresponded exactly with the SSC in only 2/52 petrous bones, and corresponded well in 7/52. The AE was lateral to the SSC in 25/52 cases, medial to the SSC in 6/52 cases, intersected in 3/52 cases, and was indiscernible in 9/52 cases. The distance between the SSC and the petrous surface was 0 mm in 45/52 petrous bones, 1 mm in 5/52, 2 mm in 1/52, and 3 mm in 1/52. The SSC typically does not correspond exactly with the AE, and is generally located just under the surface of the petrous bone. Planning of the middle cranial fossa approach requires location of the SSC by CT. (author)

  7. Influencia de la edad y la menopausia en el origen de la Dehiscencia del Canal Semicircular Superior

    OpenAIRE

    Fernández Castaño, Carmen

    2014-01-01

    145 p. : il., col. La dehiscencia del canal semicircular superior (DCSS) es una forma de vestibulopatía periférica caracterizada por la ausencia de cobertura ósea en el techo de dicho canal, de este modo su luz interior queda anormalmente abierta al espacio intracraneal en contacto directo con la meninge que tapiza el suelo de la fosa media. Esta dehiscencia se limitaría a la cápsula ótica y no afectaría, aparentemente, al laberinto membranoso. Su presentación clínica es variable, siendo ...

  8. Otitic meningitis, superior semicircular canal dehiscence, and encephalocele: a case series.

    Science.gov (United States)

    Lim, Zixiang Michael; Friedland, Peter Leon; Boeddinghaus, Rudolf; Thompson, Andrew; Rodrigues, Stephen John; Atlas, Marcus

    2012-06-01

    Otitic meningitis in the postantibiotic era is still a serious condition, requiring intensive treatment and prolonged rehabilitation. In view of the significant morbidity and mortality rate, conditions that may increase the likelihood of otitic meningitis developing should be treated promptly. The incidence of meningitis after asymptomatic encephaloceles of the middle cranial fossa varies greatly, and the management differs between elective surgical repair and expectant careful observation. Superior semicircular canal dehiscences (SSCDs) are postulated to have a congenital origin and are associated with a thin or dehiscent tegmen. Several cases of simultaneous SCCD and tegmen defects have been reported, but the findings of otitic meningitis, SCCD, and encephaloceles has, to the best of our knowledge, not been previously explored in the literature. We reviewed a series of 4 patients who all presented with a combination of otitic meningitis, encephaloceles, and SSCD. All the 4 patients we reviewed had meningitis secondary to otitis media with computed tomographic scans confirming the presence of SCCD with ipsilateral tegmen tympani defects and associated cephaloceles. All patients were treated with intravenous antibiotics and underwent surgery that ranged from myringotomy and ventilation tube insertions, mastoidectomy, and burr hole drainage for temporal lobe abscess. They were all associated with intensive care unit admission, significant morbidity, and prolonged hospital stays. There were no mortalities. We propose that in all SSCD patients, a careful computed tomographic examination of the cranial base should be undertaken to exclude other associated tegmen tympani defects. In cases of SSCD requiring surgery, we support the view that elective surgical repair be recommended where asymptomatic ipsilateral encephaloceles are found, to reduce the risk of otitic meningitis.

  9. Efferent innervation of turtle semicircular canal cristae: comparisons with bird and mouse

    Science.gov (United States)

    Jordan, Paivi M.; Fettis, Margaret; Holt, Joseph C.

    2014-01-01

    In the vestibular periphery of nearly every vertebrate, cholinergic vestibular efferent neurons give rise to numerous presynaptic varicosities that target hair cells and afferent processes in the sensory neuroepithelium. Although pharmacological studies have described the postsynaptic actions of vestibular efferent stimulation in several species, characterization of efferent innervation patterns and the relative distribution of efferent varicosities among hair cells and afferents are also integral to understanding how efferent synapses operate. Vestibular efferent markers, however, have not been well characterized in the turtle, one of the animal models utilized by our laboratory. Here, we sought to identify reliable efferent neuronal markers in the vestibular periphery of turtle, to utilize these markers to understand how efferent synapses are organized, and to compare efferent neuronal labeling patterns in turtle with two other amniotes using some of the same markers. Efferent fibers and varicosities were visualized in the semicircular canal of Red-Eared Turtles (Trachemys scripta elegans), Zebra Finches (Taeniopygia guttata), and mice (Mus musculus) utilizing fluorescent immunohistochemistry with antibodies against choline acetyltransferase (ChAT). Vestibular hair cells and afferents were counterstained using antibodies to myosin VIIa and calretinin. In all species, ChAT labeled a population of small diameter fibers giving rise to numerous spherical varicosities abutting type II hair cells and afferent processes. That these ChAT-positive varicosities represent presynaptic release sites were demonstrated by colabeling with antibodies against the synaptic vesicle proteins synapsin I, SV2, or syntaxin and the neuropeptide calcitonin gene-related peptide (CGRP). Comparisons of efferent innervation patterns among the three species are discussed. PMID:25560461

  10. Hierarchical Cluster Analysis of Semicircular Canal and Otolith Deficits in Bilateral Vestibulopathy

    Directory of Open Access Journals (Sweden)

    Alexander A. Tarnutzer

    2018-04-01

    Full Text Available BackgroundGait imbalance and oscillopsia are frequent complaints of bilateral vestibular loss (BLV. Video-head-impulse testing (vHIT of all six semicircular canals (SCCs has demonstrated varying involvement of the different canals. Sparing of anterior-canal function has been linked to aminoglycoside-related vestibulopathy and Menière’s disease. We hypothesized that utricular and saccular impairment [assessed by vestibular-evoked myogenic potentials (VEMPs] may be disease-specific also, possibly facilitating the differential diagnosis.MethodsWe searched our vHIT database (n = 3,271 for patients with bilaterally impaired SCC function who also received ocular VEMPs (oVEMPs and cervical VEMPs (cVEMPs and identified 101 patients. oVEMP/cVEMP latencies above the 95th percentile and peak-to-peak amplitudes below the 5th percentile of normal were considered abnormal. Frequency of impairment of vestibular end organs (horizontal/anterior/posterior SCC, utriculus/sacculus was analyzed with hierarchical cluster analysis and correlated with the underlying etiology.ResultsRates of utricular and saccular loss of function were similar (87.1 vs. 78.2%, p = 0.136, Fisher’s exact test. oVEMP abnormalities were found more frequent in aminoglycoside-related bilateral vestibular loss (BVL compared with Menière’s disease (91.7 vs. 54.6%, p = 0.039. Hierarchical cluster analysis indicated distinct patterns of vestibular end-organ impairment, showing that the results for the same end-organs on both sides are more similar than to other end-organs. Relative sparing of anterior-canal function was reflected in late merging with the other end-organs, emphasizing their distinct state. An anatomically corresponding pattern of SCC/otolith hypofunction was present in 60.4% (oVEMPs vs. horizontal SCCs, 34.7% (oVEMPs vs. anterior SCCs, and 48.5% (cVEMPs vs. posterior SCCs of cases. Average (±1 SD number of damaged sensors was 6.8 ± 2.2 out of 10

  11. Controle postural na síndrome de Pusher: influência dos canais semicirculares laterais Posture control in Pusher syndrome: influence of lateral semicircular canals

    Directory of Open Access Journals (Sweden)

    Taiza Elaine Grespan dos Santos Pontelli

    2005-08-01

    Full Text Available A síndrome de Pusher caracteriza-se por uma alteração do equilíbrio na qual pacientes com lesões encefálicas empurram-se em direção ao lado parético utilizando o membro não-afetado. O papel do sistema vestibular na alteração postural da síndrome de Pusher ainda não foi devidamente elucidado. OBJETIVO: Neste estudo objetivamos avaliar o papel dos canais semicirculares horizontais na expressão clínica da síndrome de Pusher, através da aplicação das provas calórica e rotatória. FORMA DE ESTUDO: Observacional, clínico e prospectivo. MATERIAL E MÉTODO: Avaliamos 9 pacientes com AVC e síndrome de Pusher internados na Enfermaria de Neurologia do HCFMRP-USP. Os pacientes foram submetidos à avaliação neurológica clínica e neuropsicológica, NIHSS, Scale for Contraversive Pushing - SCP, teste calórico e teste rotatório. RESULTADOS: Foram estudados 9 pacientes (5 homens com idade média de 71,8 ± 5,9 anos e com NIHSS médio de 18.33. Três pacientes apresentaram preponderância direcional contralateral à lesão encefálica na prova calórica. Na prova rotatória, foram observados quatro pacientes com preponderância direcional na análise de velocidade da componente lenta. CONCLUSÃO: Os resultados do presente estudo indicam que a disfunção dos canais semicirculares não parece ser fundamental para a expressão da síndrome de Pusher.Pusher syndrome is an interesting disorder of balance in patients with encephalic lesions characterized by the peculiar behavior of actively pushing away from the non-hemiparetic side and resisting against passive correction, with a tendency to fall toward the paralyzed side. The role of vestibular system on the pushing behavior is not clear. AIM: To evaluate horizontal semicircular canal function in patients with Pusher syndrome, using caloric and rotation tests. STUDY DESIGN: Observational prospective. MATERIAL AND METHOD: We evaluated 9 inpatients with stroke and Pusher syndrome at the

  12. Mechanical properties and motion of the cupula of the human semicircular canal.

    Science.gov (United States)

    Selva, Pierre; Oman, Charles M; Stone, Howard A

    2009-01-01

    The mathematical model for the dynamics of the cupula-endolymph system of the inner ear semicircular canal, as elaborated by numerous investigators, remains a foundational tool in all of vestibular physiology. Most models represent the cupula as a linear spring-like element of stiffness K=DeltaP/DeltaV, where DeltaV is the volume displaced upon application of a pressure difference DeltaP. The parameter K directly influences the long time constant of the cupula-endolymph system. Given estimates of K based on experiments, we use thick and thin bending membrane theory, and also finite-element simulations based on more realistic cupula morphologies, to estimate the human cupula's Young's modulus E approximately 5.4 Pa. We show that for a model morphology, thick bending membrane theory and finite-element predictions are in good agreement, and conclude that the morphology of the attachment of the cupula to the slope of the crista should not greatly influence the volume displacement. We note, however, that other biological materials with very low E are hydrogels that have significant viscoelastic properties. Experiments to directly measure E and investigate potential viscoelastic behavior ultimately may be needed. In addition, based on experimental images we study two other different shapes for the cupula and quantify their impact on the deflection of the cupula. We also use a three-dimensional finite-element model to analyze both the shear strain distribution and its time evolution near the sensory epithelium. We conclude that stimulation of sensory hair cells probably begins at the centre of the crista and spreads toward the periphery of the cupula and down the sides of the crista. Thus, spatio-temporal variations in the shearing stimulus are predicted to impact subsequent transduction and encoding. Finally, modeling the fluid-filled vertical channels believed to lie within the cupula, we investigate the impact of different tube diameters on the transverse displacement

  13. [Clinical research of the otolith abnormal migration during canalith repositioning procedures for posterior semicircular canal benign paroxysmal positional vertigo].

    Science.gov (United States)

    Ou, Yongkang; Zheng, Yiging; Zhu, Honglei; Chen, Ling; Zhong, Junwei; Tang, Xiaowu; Huang, Qiuhong; Xu, Yaodong

    2015-01-01

    To investigate the risk factor,type and characteristic nystagmus of the otolith abnormal migration during diagnosis and treatment for posterior semicircular canal benign paroxysmal positional vertigo (PSC-BPPV). The therapy and prevention is also discussed. Four hundred and seventy-nine patients with PSC-BPPV were treated by Epley's canalith repositioning procedures(CRP) from March 2009 to March 2012. We observed otolith abnormal migration complicating during diagnosis and treatment. According the type of otolith abnormal migration, the additional repositioning maneuver was performed. The rate of complication was 8. 1%(39/479), with canal conversion in 5.4%(26/479) and primarily canal reentry in 2.7%(13/479). The rate of incidence of conversion to horizontal canal conversion and anterior canal were 4. 8%(23/479)and 0. 6%(3/479) respectively. All the patient was cured in follow up. The risk factors were unappropriated head movement during or after CRP, including another Dix-Hallpike were performed immediately. To prevent the complications,the pathognostic positioning sequence and angle of head rotation are commenced during CRP. Appropriate short time postural restrictions post-treatment is necessary. Careful observation of nystagrnus variation is crucial to determine the otolith abnormal migration.

  14. Ca(2+) currents and voltage responses in Type I and Type II hair cells of the chick embryo semicircular canal.

    Science.gov (United States)

    Masetto, Sergio; Zampini, Valeria; Zucca, Giampiero; Valli, Paolo

    2005-11-01

    Type I and Type II hair cells, and Type II hair cells located in different zones of the semicircular canal crista, express different patterns of voltage-dependent K channels, each one specifically shaping the hair cell receptor potential. We report here that, close to hatching, chicken embryo semicircular canal Type I and Type II hair cells express a similar voltage-dependent L-type calcium current (I(Ca)), whose main features are: activation above -60 mV, fast activation kinetics, and scarce inactivation. I(Ca) should be already active at rest in Zone 1 Type II hair cells, whose resting membrane potential was on average slightly less negative than -60 mV. Conversely, I(Ca) would not be active at rest in Type II hair cells from Zone 2 and 3, nor in Type I hair cells, since their resting membrane potential was significantly more negative than -60 mV. However, even small depolarising currents would activate I(Ca) steadily in Zone 2 and 3 Type II hair cells, but not in Type I hair cells because of the robust repolarising action of their specific array of K(+) currents. The implications of the present findings in the afferent discharge are discussed.

  15. The induction and compensation of asymmetric eye movements following unilateral blockage of a horizontal semicircular canal in the rabbit.

    Science.gov (United States)

    Barmack, N H; Pettorossi, V E

    1988-08-01

    The influence of unilateral plugs of the left horizontal semicircular canal (LHC plugs) of rabbits on the development and compensation of asymmetric eye movements evoked by horizontal vestibular stimulation was studied. LHC plugs caused an immediate reduction of 50-65% in the gain of the horizontal vestibuloocular reflex (HVOR). This reduction in gain was achieved without altering the symmetry of the HVOR, and was accompanied by a change in the axial alignment of eye movements evoked by vestibular stimulation about the vertical (HVOR) and longitudinal (VVOR) axes. Postoperative asymmetry of eye movements developed 12-48 hr after the plugging operation. The development of asymmetry was reduced if the rabbit was restrained for 24 hr, thereby minimizing vestibular stimulation following the plugging operation. Over a 3-4 week period, the normal symmetry of eye movements was restored and the axial alignments of the HVOR and VVOR returned to the preoperative values. The gain of the HVOR did not recover. The horizontal cervicoocular reflex (HCOR) was examined before the plugging operation and after compensation of asymmetry was complete. The gain and phase of the HCOR were not altered. A relatively simple set of explanations at a cellular level is proposed to account for the induction and compensation of asymmetric eye movements following a unilateral plug of the horizontal semicircular canal.

  16. Influence of gravity on the spatial orientation of eye nystagmus induced by unilateral lesion of horizontal semicircular canal.

    Science.gov (United States)

    Pettorossi, V E; Ermanno, M; Pierangelo, E; Silvarosa, G

    2000-03-01

    The influence of gravity in the orientation and slow phase eye velocity of the ocular nystagmus following unilateral damage of the cupula in the ampulla of the horizontal semicircular canal (UHCD) was investigated. The nystagmus was analysed at different sagittal head positions using the x-y infrared eye monitor technique. The nystagmus was almost horizontal at 0 degrees head pitch angle and remained partially fixed in space when the head was pitched upward or downward. The reorientation gain of the slow and quick phases was high (about 0.75) within +/- 45 degrees of head pitch angle, but beyond this range, it decreased greatly. The gain value depended on the lesion extension to otolithic receptors. The absolute value of the slow phase eye velocity of UHCD nystagmus was also modified systematically by the head pitch, showing a reduction in the upward and an increase in the downward.

  17. Superior semicircular canal dehiscence in relation to the superior petrosal sinus: a potential cause of pulsatile tinnitus

    International Nuclear Information System (INIS)

    Liu, Z.; Bi, W.; Li, J.; Li, Q.; Dong, C.; Zhao, P.; Lv, H.; Wang, Z.

    2015-01-01

    Aim: To examine the association between superior semicircular canal dehiscence (SSCD) and pulsatile tinnitus (PT). Materials and methods: Two SSCD groups included 408 unilateral persistent PT patients, and 511 controls undergoing head and neck dual-phase contrast-enhanced computed tomography (DP-CECT) for reasons other than PT. The prevalence of type I (no the superior petrosal sinus running through the dehiscence) and type II (superior semicircular canal dehiscence in relation to the superior petrosal sinus) SSCD was analysed using chi-square test. Results: SSCD was identified in 5.1% (21/408) of PT ears, significantly different from 2% (8/408) of non-PT ears and 0.7% (7/1022) of controls. There was no significant difference in SSCD prevalence between non-PT ears in the PT group and controls. In the PT group, 15/21 ears were type II SSCD; 6/21 ears were type I. Fifteen combined non-PT and control ears with SSCD included two type II and 13 type I SSCD. The prevalence of type II SSCD in PT ears was significantly higher than that of non-PT ears in both groups, and the prevalence of type I SSCD in PT ears was similar to that of non-PT ears in both groups. Conclusion: Compared with type I SSCD, there may be a causal relationship between type II SSCD and PT. -- Highlights: •The prevalence of type II SSCD in PT ears was significantly higher than that in non-PT ears in both the PT group and controls. •The prevalence of type I SSCD was similar among the PT ears and non-PT ears. •The superior petrosal sinus running through the dehiscence may be essential for SSCD to induce PT. •Venous phase CT images with bone window settings is the modality method to differentiate type II from type I SSCD

  18. Prevalence of radiographic semicircular canal dehiscence in very young children: an evaluation using high-resolution computed tomography of the temporal bones

    International Nuclear Information System (INIS)

    Hagiwara, Mari; Fatterpekar, Girish; Shaikh, Jamil A.; Fang, Yixin; Roehm, Pamela C.

    2012-01-01

    Previous studies suggest that semicircular canal dehiscences (SCDs) have a developmental origin. We hypothesized that if SCDs originate during development, incidence of radiographic SCDs in young children will be higher than in adults. Thirty-four temporal bone HRCTs of children younger than 2 years and 40 temporal bone HRCTs of patients older than 18 years were reformatted and re-evaluated for presence of SCD or canal thinning. Results were compared with indications for HRCT and clinical information. SCDs were detected in 27.3% of children younger than 2 years of age (superior, 13.8%; posterior, 20%) and in 3% of adults (P < 0.004). Of children with one radiographic dehiscence, 55.6% had multiple and 44% had bilateral SCDs on HRCT. No lateral canal SCDs were present. Thinning of bone overlying the semicircular canals was found in 44% of children younger than 2 years and 2.5% of adults (P < 0.0001). SCDs are more common on HRCTs of very young children. This supports the hypothesis that SCDs originate from discontinuation of bone deposition/maturation. However, SCDs on imaging do not necessarily correlate with canal dehiscence syndrome and should therefore be interpreted carefully. (orig.)

  19. Prevalence of radiographic semicircular canal dehiscence in very young children: an evaluation using high-resolution computed tomography of the temporal bones

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Mari; Fatterpekar, Girish [New York University School of Medicine, Department of Radiology, New York, NY (United States); Shaikh, Jamil A. [New York University School of Medicine, Department of Otolaryngology, New York, NY (United States); Fang, Yixin [New York University School of Medicine, Department of Otolaryngology, New York, NY (United States); New York University School of Medicine, Division of Biostatistics, Department of Environmental Medicine, New York, NY (United States); Roehm, Pamela C. [New York University School of Medicine, Department of Otolaryngology, New York, NY (United States); New York University School of Medicine, Department of Otolaryngology, Division of Otology/Neurotology, New York, NY (United States)

    2012-12-15

    Previous studies suggest that semicircular canal dehiscences (SCDs) have a developmental origin. We hypothesized that if SCDs originate during development, incidence of radiographic SCDs in young children will be higher than in adults. Thirty-four temporal bone HRCTs of children younger than 2 years and 40 temporal bone HRCTs of patients older than 18 years were reformatted and re-evaluated for presence of SCD or canal thinning. Results were compared with indications for HRCT and clinical information. SCDs were detected in 27.3% of children younger than 2 years of age (superior, 13.8%; posterior, 20%) and in 3% of adults (P < 0.004). Of children with one radiographic dehiscence, 55.6% had multiple and 44% had bilateral SCDs on HRCT. No lateral canal SCDs were present. Thinning of bone overlying the semicircular canals was found in 44% of children younger than 2 years and 2.5% of adults (P < 0.0001). SCDs are more common on HRCTs of very young children. This supports the hypothesis that SCDs originate from discontinuation of bone deposition/maturation. However, SCDs on imaging do not necessarily correlate with canal dehiscence syndrome and should therefore be interpreted carefully. (orig.)

  20. [Efficacy of quick repositioning maneuver for posterior semicircular canal benign paroxysmal positional vertigo in different age groups].

    Science.gov (United States)

    Zhang, Hao; Li, Jinrang; Guo, Pengfei; Tian, Shiyu; Li, Keliang

    2015-12-01

    To observe the short and long-term efficacy of quick repositioning maneuver for posterior semicircular canal benign paroxysmal positional vertigo (PC-BPPV) in different age groups. The clinical data of 113 adult patients with single PC-BPPV who underwent quick repositioning maneuver from July 2009 to February 2015 were retrospectively analyzed. The quick repositioning maneuver was to roll the patient from involved side to healthy side in the coronal plane for 180° as quickly as possible. The patients were divided into 3 groups according to different ages: young group (age group (45 ≤ age group (≥ 60 years). The short and long term outcomes of the three groups were observed. The left ear was involved in 58 cases (51.3%) and the right ear in 55 cases (48.7%). The short term improvement rates of the young, middle-age and the old groups were 92.5%, 93.6% and 92.3% respectively, and the long term improvement rate was 90.0%, 85.1% and 73.1% respectively. There was no significant difference among the three groups in short and long term outcomes (P > 0.05). The recurrence rate of the three groups was 5.0%, 6.4% and 15.4% respectively, also no significant difference (P > 0.05). The quick repositioning maneuver along the coronal plane for PC-BPPV has a definite effect for every age groups. The method is simple, rapid and easy to master, and the patients are tolerated the maneuver well without evident side effect.

  1. Hearing eyeball and/or eyelid movements on the side of a unilateral superior semicircular canal dehiscence.

    Science.gov (United States)

    Bertholon, Pierre; Reynard, Pierre; Lelonge, Yann; Peyron, Roland; Vassal, François; Karkas, Alexandre

    2018-02-01

    Hearing of eyeball movements has been reported in superior semicircular canal dehiscence (SSCD), but not hearing of eyelid movements. Our main objective was to report the hearing of eyeball and/or eyelid movements in unilateral SSCD. Our secondary objective was to access its specificity to SSCD and discuss the underlying mechanism. Six patients with SSCD who could hear their eyeball and/or eyelid movements were retrospectively reviewed. With the aim of comparisons, eight patients with an enlarged vestibular aqueduct (EVA), who share the same mechanism of an abnormal third window, were questioned on their ability to hear their eyeball and/or eyelid movements. Three patients with SSCD could hear both their eyeball and eyelid movements as a soft low-pitch friction sound. Two patients with SSCD could hear only their eyelid movements, one of whom after the surgery of a traumatic chronic subdural hematoma. The latter remarked that every gently tapping on the skin covering the burr-hole was heard in his dehiscent ear as the sound produced when banging on a drum, in keeping with a direct transmission of the sound to the inner ear via the cerebrospinal fluid. One patient with SSCD, who could hear only his eyeball movements, had other disabling symptoms deserving operation through a middle fossa approach with an immediate relief of his symptoms. None of the eight patients with EVA could hear his/her eyeball or eyelid movements. Hearing of eyeball and/or eyelid movements is highly suggestive of a SSCD and do not seem to occur in EVA. In case of radiological SSCD, clinicians should search for hearing of eyeball and/or eyelid movements providing arguments for a symptomatic dehiscence. The underlying mechanism is discussed particularly the role of a cerebrospinal fluid transmission.

  2. The variability of inner ear orientation in saurischian dinosaurs: testing the use of semicircular canals as a reference system for comparative anatomy

    Directory of Open Access Journals (Sweden)

    Jesús Marugán-Lobón

    2013-08-01

    Full Text Available The vestibular system of the inner ear houses three semicircular canals—oriented on three nearly-orthogonal planes—that respond to angular acceleration stimuli. In recent years, the orientation of the lateral semicircular canal (LSC has been regularly used to determine skull orientations for comparative purposes in studies of non-avian dinosaurs. Such orientations have been inferred based on fixing the LSC to a common set of coordinates (parallel to the Earth’s horizon, given that the orientation to gravity of this sensory system is assumed constant among taxa. Under this assumption, the LSC is used as a baseline (a reference system both to estimate how the animals held their heads and to describe craniofacial variation among dinosaurs. However, the available data in living birds (extant saurischian dinosaurs suggests that the orientation of the LSC in non-avian saurischian dinosaurs could have been very variable and taxon-specific. If such were the case, using the LSC as a comparative reference system would cause inappropriate visual perceptions of craniofacial organization, leading to significant descriptive inconsistencies among taxa. Here, we used Procrustes methods (Geometric Morphometrics, a suite of analytical tools that compares morphology on the basis of shared landmark homology, to show that the variability of LSC relative to skull landmarks is large (ca. 50° and likely unpredictable, thus making it an inconsistent reference system for comparing and describing the skulls of saurischian (sauropodomorph and theropod dinosaurs. In light of our results, the lateral semicircular canal is an inconsistent baseline for comparative studies of craniofacial morphology in dinosaurs.

  3. Long-term results of middle fossa plugging of superior semicircular canal dehiscences: clinically and instrumentally demonstrated efficiency in a retrospective series of 16 ears.

    Science.gov (United States)

    Thomeer, Hans; Bonnard, Damien; Castetbon, Vincent; Franco-Vidal, Valérie; Darrouzet, Patricia; Darrouzet, Vincent

    2016-07-01

    The objective of this study is to report the surgical outcome after middle fossa approach (MFA) plugging in patients suffering from a superior semi-circular canal dehiscence (SCD) syndrome. This is a retrospective case review. Tertiary referral center. Sixteen ears in 13 patients with a SCD syndrome suffering from severe and disabling vestibular symptoms with a bony dehiscence on CT scan >3 mm and decreased threshold of cervical vestibular evoked potentials (cVEMPs). We assessed preoperatively: clinical symptoms, hearing, cVEMPs threshold, size of dehiscence and videonystagmography (VNG) with caloric and 100 Hz vibratory tests. Postoperatively, we noted occurrences of neurosurgical complication, evolution of audiological and vestibular symptoms, and evaluation of cVEMP data. Tullio's phenomenon was observed in 13 cases (81.3 %) and subjectively reported hearing loss in seven (43.7 %). All patients were so disabled that they had to stop working. No neurosurgical complications were observed in the postoperative course. In three cases (16.6 %), an ipsilateral and transitory immediate postoperative vestibular deficit associated with a sensorineural hearing loss (SNHL) was noted, which totally resolved with steroids and bed rest. All patients were relieved of audiological and vestibular symptoms and could return to normal activity with a mean follow-up of 31.1 months (range 3-95). No patient had residual SNHL. cVEMPs were performed in 14 ears postoperatively and were normalized in 12 (85.7 %). Two of the three patients operated on both sides kept some degree of unsteadiness and oscillopsia. MFA plugging of the superior semi-circular canal is an efficient and non-hearing deteriorating procedure.

  4. [High-frequency rotation sensation function damage of the crista of the horizontal semicircular canal induced by gentamicin and its morphological basis.].

    Science.gov (United States)

    Chen, Liang; He, Ming; Wang, Wu-Qing

    2009-12-25

    The goal of the present study was to explore high-frequency rotation sensation function damage of the crista of the horizontal semicircular canal induced by gentamicin and its morphological basis. The guinea pigs were randomly divided into four groups (group 1, 2, 3 and control group, n=20). The animals of treated groups received gentamicin subcutaneously (50 mg/kg per day) for 1 week (group 1), 2 weeks (group 2) and 3 weeks (group 3), respectively. The animals of control group were administered with equal volume of saline subcutaneously. Videonystagmography (VNG) evoked by ice water or high-frequency rotations, and vestibular evoked potential (VsEP) evoked by low- and high-frequency rotations were recorded after the administration. After VNG and VsEP were examined, the cristae of the horizontal semicircular canals were prepared for scanning and transmission electron microscopy. The results are as follows: (1) In VNG examination, after ice water stimulation, no obvious nystagmus was observed in the animals of group 3, and there was no significant difference in nystagmus frequency and duration among group 1, 2 and control group (P>0.05). After high- frequency rotations, no obvious nystagmus was yet observed in the animals of group 3. There were significant differences in the nystagmus frequency and duration of the VNG waves between the experimental group 2 and control group (P0.05). (2) In VsEP examination, there was no significant difference in the parameters of VsEP among group 1, 2 and control group (P>0.05), and VsEP was not observed in group 3 after low-frequency rotations. After high- frequency rotations, compared with control group, the latencies and amplitudes of P1 and P2 in group 2 significantly decreased (P0.05). Group 3 had no response of VsEP to high-frequency rotations. (3) Electron microscopy was used to observe the crista hair cells of the four groups. In control group, the hair cells were normal. In group 1, almost normal appearance with slight

  5. Long-term outcomes of a transmastoid lateral semicircular canal approach to congenital CSF otorrhea in children associated with recurrent meningitis and severe inner ear malformation.

    Science.gov (United States)

    Wang, Jie; Li, Yongxin; Chen, Shubin; Hao, Xinping

    2016-08-01

    To investigate the long-term effectiveness of transmastoid lateral semicircular canal approach (TMLSCCA) to repair cerebrospinal fluid (CSF) leakage in children associated with recurrent meningitis and severe congenital inner malformation. A retrospective study was conducted in a university hospital, academic medical center. Fifteen children with recurrent meningitis, secondary to severe congenital inner ear malformation, were included in the study. All of them had CSF associated otorrhea and treated using TLSCCA to repair CSF otorrhea by packing the vestibule with muscle and fascia. Observation of the status of postoperative CSF leakage, recurrence of meningitis and complication were conducted. None of the cases had recurrent meningitis and CSF leakage after their TLSCCA procedure in the follow-up period of 1-8.5 years. One case presented with transient facial nerve paralysis and completely recovered 3 months later. TLSCCA for CSF otorrhea in children with recurrent meningitis secondary to congenital inner ear malformation is an alternative approach that offers some advantages. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. The reliability of nonlinear least-squares algorithm for data analysis of neural response activity during sinusoidal rotational stimulation in semicircular canal neurons.

    Science.gov (United States)

    Ren, Pengyu; Li, Bowen; Dong, Shiyao; Chen, Lin; Zhang, Yuelin

    2018-01-01

    Although many mathematical methods were used to analyze the neural activity under sinusoidal stimulation within linear response range in vestibular system, the reliabilities of these methods are still not reported, especially in nonlinear response range. Here we chose nonlinear least-squares algorithm (NLSA) with sinusoidal model to analyze the neural response of semicircular canal neurons (SCNs) during sinusoidal rotational stimulation (SRS) over a nonlinear response range. Our aim was to acquire a reliable mathematical method for data analysis under SRS in vestibular system. Our data indicated that the reliability of this method in an entire SCNs population was quite satisfactory. However, the reliability was strongly negatively depended on the neural discharge regularity. In addition, stimulation parameters were the vital impact factors influencing the reliability. The frequency had a significant negative effect but the amplitude had a conspicuous positive effect on the reliability. Thus, NLSA with sinusoidal model resulted a reliable mathematical tool for data analysis of neural response activity under SRS in vestibular system and more suitable for those under the stimulation with low frequency but high amplitude, suggesting that this method can be used in nonlinear response range. This method broke out of the restriction of neural activity analysis under nonlinear response range and provided a solid foundation for future study in nonlinear response range in vestibular system.

  7. The prevalence of superior semicircular canal dehiscence in conductive and mixed hearing loss in the absence of other pathology using submillimetric temporal bone computed tomography.

    Science.gov (United States)

    Lee, Young Hen; Rivas-Rodriguez, Francisco; Song, Jae-Jun; Yang, Kyung-Sook; Mukherji, Suresh K

    2014-01-01

    The objective of this study was to assess the relationship between superior semicircular canal dehiscence (SSCD) and hearing impairment. We retrospectively compared the prevalence of SSCD in the ears classified as conductive hearing loss (CHL), mixed hearing loss (MHL), and normal hearing status using submillimetric temporal bone computed tomography (TBCT) on the basis of coronal and additional reformatted planes dedicated to SSCD. From the patients with CHL (n = 127) and MHL (n = 45), the overall prevalence of SSCD in the ears classified as CHL, MHL, and normal hearing status were 6.6%, 7.2%, and 3.0%, respectively. Furthermore, the odds ratio for SSCD in the absence of any cause of hearing loss (eg, dysfunction of the tympanic membrane or middle ear, TBCT abnormalities, otosclerosis, trauma, surgery) was 5.35 in MHL (4/27; P = 0.037, 95% confidence interval, 1.1-25.81) and 3.31 in CHL (5/61; P = 0.115, 95% confidence interval, 0.75-14.63), compared with normal hearing status. Bony covering of the SSC should be specifically evaluated in patients with hearing impairment using submillimetric TBCT.

  8. Prospective radiological study concerning a series of patients suffering from conductive or mixed hearing loss due to superior semicircular canal dehiscence.

    Science.gov (United States)

    Martin, Christian; Chahine, Pierre; Veyret, Charles; Richard, Céline; Prades, Jean Michel; Pouget, Jean François

    2009-08-01

    The aim of this study is to appreciate the incidence of patients with isolated conductive hearing loss with normal drum due to superior semicircular canal dehiscence (SCD). It is a prospective radiological study. Two hundred and seventy-two patients with a normal drum suffering from isolated unilateral or bilateral conductive or mixed hearing loss were included in a prospective radiological study. A high resolution computerized tomography (HRCT) was performed in all the patients. Those who were found to have a unilateral or bilateral SCD underwent further etiological, clinical, audiologic evaluation. Ten patients with conductive or mixed hearing loss were found to have a unilateral or bilateral SCD. The disease was bilateral in five cases, and most often associated with a dehiscence of the tegmen tympani on both sides, supporting the theory of the congenital nature of the disease. There was no clear correlation between symptoms and the size of the SCD. Because patients were not suffering from incapacitating vestibular symptoms, they were not operated for surgical occlusion of the SCD, and were referred to a hearing aid specialist to improve hearing. Conductive or mixed hearing loss due to SCD is relatively frequent, justifying in our opinion that a systematic HRCT be carried out before surgery of any patient with conductive hearing loss.

  9. Single-channel L-type Ca2+ currents in chicken embryo semicircular canal type I and type II hair cells.

    Science.gov (United States)

    Zampini, Valeria; Valli, Paolo; Zucca, Giampiero; Masetto, Sergio

    2006-08-01

    Few data are available concerning single Ca channel properties in inner ear hair cells and particularly none in vestibular type I hair cells. By using the cell-attached configuration of the patch-clamp technique in combination with the semicircular canal crista slice preparation, we determined the elementary properties of voltage-dependent Ca channels in chicken embryo type I and type II hair cells. The pipette solutions included Bay K 8644. With 70 mM Ba(2+) in the patch pipette, Ca channel activity appeared as very brief openings at -60 mV. Ca channel properties were found to be similar in type I and type II hair cells; therefore data were pooled. The mean inward current amplitude was -1.3 +/- 0.1 (SD) pA at - 30 mV (n = 16). The average slope conductance was 21 pS (n = 20). With 5 mM Ba(2+) in the patch pipette, very brief openings were already detectable at -80 mV. The mean inward current amplitude was -0.7 +/- 0.2 pA at -40 mV (n = 9). The average slope conductance was 11 pS (n = 9). The mean open time and the open probability increased significantly with depolarization. Ca channel activity was still present and unaffected when omega-agatoxin IVA (2 microM) and omega-conotoxin GVIA (3.2 microM) were added to the pipette solution. Our results show that types I and II hair cells express L-type Ca channels with similar properties. Moreover, they suggest that in vivo Ca(2+) influx might occur at membrane voltages more negative than -60 mV.

  10. Multi-channel Kondo necklace

    International Nuclear Information System (INIS)

    Fazekas, P.; Kee Haeyoung.

    1993-06-01

    A multi-channel generalization of Doniach's Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins τ J , j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig

  11. Multi-channel Kondo necklace

    Energy Technology Data Exchange (ETDEWEB)

    Fazekas, P; Haeyoung, Kee

    1993-06-01

    A multi-channel generalization of Doniach`s Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins {tau}{sub J}, j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig.

  12. Digital Multi Channel Analyzer Enhancement

    International Nuclear Information System (INIS)

    Gonen, E.; Marcus, E.; Wengrowicz, U.; Beck, A.; Nir, J.; Sheinfeld, M.; Broide, A.; Tirosh, D.

    2002-01-01

    A cement analyzing system based on radiation spectroscopy had been developed [1], using novel digital approach for real-time, high-throughput and low-cost Multi Channel Analyzer. The performance of the developed system had a severe problem: the resulted spectrum suffered from lack of smoothness, it was very noisy and full of spikes and surges, therefore it was impossible to use this spectrum for analyzing the cement substance. This paper describes the work carried out to improve the system performance

  13. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  14. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  15. Modelling customer behaviour in multi-channel service distribution

    NARCIS (Netherlands)

    Heinhuis, D.; de Vries, E.J.; Kundisch, D.; Veit, D.J.; Weitzel, T.; Weinhardt, C.

    2009-01-01

    Financial service providers are innovating their distribution strategy into multi-channel strategies. The success of a multi-channel approach and the high investments made in information systems and enterprise architectures depends on the adoption and multi-channel usage behaviour of consumers. We

  16. A multi-channel coronal spectrophotometer.

    Science.gov (United States)

    Landman, D. A.; Orrall, F. Q.; Zane, R.

    1973-01-01

    We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

  17. A low power Multi-Channel Analyzer

    International Nuclear Information System (INIS)

    Anderson, G.A.; Brackenbush, L.W.

    1993-06-01

    The instrumentation used in nuclear spectroscopy is generally large, is not portable, and requires a lot of power. Key components of these counting systems are the computer and the Multi-Channel Analyzer (MCA). To assist in performing measurements requiring portable systems, a small, very low power MCA has been developed at Pacific Northwest Laboratory (PNL). This MCA is interfaced with a Hewlett Packard palm top computer for portable applications. The MCA can also be connected to an IBM/PC for data storage and analysis. In addition, a real-time time display mode allows the user to view the spectra as they are collected

  18. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping

    2016-05-18

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  19. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    In this paper, a method for multi-channel pitch estimation is proposed. The method is a maximum likelihood estimator and is based on a parametric model where the signals in the various channels share the same fundamental frequency but can have different amplitudes, phases, and noise characteristics....... This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  20. Multi-channel coherent perfect absorbers

    KAUST Repository

    Bai, Ping; Wu, Ying; Lai, Yun

    2016-01-01

    The absorption efficiency of a coherent perfect absorber usually depends on the phase coherence of the incident waves on the surfaces. Here, we present a scheme to create a multi-channel coherent perfect absorber in which the constraint of phase coherence is loosened. The scheme has a multi-layer structure such that incident waves in different channels with different angular momenta can be simultaneously and perfectly absorbed. This absorber is robust in achieving high absorption efficiency even if the incident waves become "incoherent" and possess "random" wave fronts. Our work demonstrates a unique approach to designing highly efficient metamaterial absorbers. © CopyrightEPLA, 2016.

  1. Canal switch after canalith repositioning procedure for benign paroxysmal positional vertigo.

    Science.gov (United States)

    Lin, Giant C; Basura, Gregory J; Wong, Hiu Tung; Heidenreich, Katherine D

    2012-09-01

    Canal switch is a complication following canalith repositioning procedure (CRP) for posterior canal benign paroxysmal positional vertigo (BPPV). Instead of being returned to the utricle, the loose otoconia migrate into the superior or horizontal semicircular canal. Patients remain symptomatic, and treatment can be ineffective unless the switch is recognized and additional repositioning maneuvers directed toward the appropriate semicircular canal are performed. This report provides the first videographic documentation of canal switch involving conversion of unilateral posterior semicircular canal BPPV to geotropic horizontal canalithiasis. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Skyrmion-based multi-channel racetrack

    Science.gov (United States)

    Song, Chengkun; Jin, Chendong; Wang, Jinshuai; Xia, Haiyan; Wang, Jianbo; Liu, Qingfang

    2017-11-01

    Magnetic skyrmions are promising for the application of racetrack memories, logic gates, and other nano-devices, owing to their topologically protected stability, small size, and low driving current. In this work, we propose a skyrmion-based multi-channel racetrack memory where the skyrmion moves in the selected channel by applying voltage-controlled magnetic anisotropy gates. It is demonstrated numerically that a current-dependent skyrmion Hall effect can be restrained by the additional potential of the voltage-controlled region, and the skyrmion velocity and moving channel in the racetrack can be operated by tuning the voltage-controlled magnetic anisotropy, gate position, and current density. Our results offer a potential application of racetrack memory based on skyrmions.

  3. Multi-channel data acquisition system for CT

    International Nuclear Information System (INIS)

    Cao Fuqiang; He Bin; Liu Guohua; Xu Minjian

    2009-01-01

    The architecture design and realization of a data acquisition system for multi-channel CT is described. The article introduces the conversion of analog signal to digital signal, the data cache and transmission. This data acquisition system can be widely used in the system which requires the multi-channel, weak current signal detection. (authors)

  4. Computer-based multi-channel analyzer based on internet

    International Nuclear Information System (INIS)

    Zhou Xinzhi; Ning Jiaoxian

    2001-01-01

    Combined the technology of Internet with computer-based multi-channel analyzer, a new kind of computer-based multi-channel analyzer system which is based on browser is presented. Its framework and principle as well as its implementation are discussed

  5. Multi-channel mechanical test machine for HANARO (I)

    International Nuclear Information System (INIS)

    Song, M. S.; Choi, Y.; Cho, M. S.; Kim, B. G.; Kang, Y. H.

    2004-01-01

    Design and fabrication of multi-channel mechanical test machine is useful and important for the study of in-pile test of nuclear materials in HANARO. The dimension and shape of the multi-channel mechanical test machine should be fixed to a test reactor and their objectives. KAERI successfully developed a non-instrumented multi-channel mechanical test machine for material irradiation tests in a domestic research reactor, HANARO. This results in strongly stimulating and accelerating irradiation tests of materials in domestic industry and research fields with HANARO. Although various types of in-pile creep capsule were made for well installation in each test reactor, there is no in-pile creep multi-channel mechanical test machine for HANARO. Hence, the objectives of this study are to fabricate and test a multi-channel mechanical test machine of HANARO

  6. Multi-Channel Capacitive Sensor Arrays

    Directory of Open Access Journals (Sweden)

    Bingnan Wang

    2016-01-01

    Full Text Available In this paper, multi-channel capacitive sensor arrays based on microstrip band-stop filters are studied. The sensor arrays can be used to detect the proximity of objects at different positions and directions. Each capacitive sensing structure in the array is connected to an inductive element to form resonance at different frequencies. The resonances are designed to be isolated in the frequency spectrum, such that the change in one channel does not affect resonances at other channels. The inductive element associated with each capacitive sensor can be surface-mounted inductors, integrated microstrip inductors or metamaterial-inspired structures. We show that by using metamaterial split-ring structures coupled to a microstrip line, the quality factor of each resonance can be greatly improved compared to conventional surface-mounted or microstrip meander inductors. With such a microstrip-coupled split-ring design, more sensing elements can be integrated in the same frequency spectrum, and the sensitivity can be greatly improved.

  7. Multi-channel phase-equivalent transformation and supersymmetry

    OpenAIRE

    Shirokov, A. M.; Sidorenko, V. N.

    2000-01-01

    Phase-equivalent transformation of local interaction is generalized to the multi-channel case. Generally, the transformation does not change the number of the bound states in the system and their energies. However, with a special choice of the parameters, the transformation removes one of the bound states and is equivalent to the multi-channel supersymmetry transformation recently suggested by Sparenberg and Baye. Using the transformation, it is also possible to add a bound state to the discr...

  8. Essays on Online and Multi-Channel Marketing

    OpenAIRE

    Zhang, Lingling

    2016-01-01

    Firms increasingly adopt online and multi-channel marketing strategies to reach and persuade consumers. Therefore, designing an effective marketing mix is critical to their success. The aim of my dissertation is to understand the strategy behind firms’ channel choices and assess marketing effectiveness. It consists of three large-scale empirical studies examining several important aspects of online and multi-channel marketing. My first essay focuses on the business-to-business (B2B) inte...

  9. The Buywell Way: seven essential practices of a highly successful multi-channel e-tailer

    Directory of Open Access Journals (Sweden)

    Mary Tate

    2005-05-01

    Full Text Available After the dot-com bust there is considerable evidence that multi-channel retailers are more successful than purely on-line retailers. Multi-channel retailing is becoming mainstream and considerable research exists on successful multi-channel strategies. Despite this, some organisations are having more success than others with their multi-channel approach. We talked to the management of one of Australasia’s most successful multi-channel apparel and home-ware retailers about the theory and practice of multi-channel retailing, with the aim of building on existing theory in multi-channel e-commerce.

  10. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  11. Multi-channel electronically scanned cryogenic pressure sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Kruse, Nancy M. H. (Inventor)

    1995-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multielement array. These dies are bonded at specific sites on a glass, prepatterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  12. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630

  13. A high-speed interface for multi-channel analyzer

    International Nuclear Information System (INIS)

    Shen Ji; Zheng Zhong; Qiao Chong; Chen Ziyu; Ye Yunxiu; Ye Zhenyu

    2003-01-01

    This paper presents a high-speed computer interface for multi-channel analyzer based on DMA technique. Its essential principle and operating procedure are introduced. By the detecting of γ spectrum of 137 Cs with the interface, it's proved that the interface can meet the requirements of high-speed data acquisition

  14. Dense Clustered Multi-Channel Wireless Sensor Cloud

    Directory of Open Access Journals (Sweden)

    Sivaramakrishnan Sivakumar

    2015-08-01

    Full Text Available Dense Wireless Sensor Network Clouds have an inherent issue of latency and packet drops with regards to data collection. Though there is extensive literature that tries to address these issues through either scheduling, channel contention or a combination of the two, the problem still largely exists. In this paper, a Clustered Multi-Channel Scheduling Protocol (CMSP is designed that creates a Voronoi partition of a dense network. Each partition is assigned a channel, and a scheduling scheme is adopted to collect data within the Voronoi partitions. This scheme collects data from the partitions concurrently and then passes it to the base station. CMSP is compared using simulation with other multi-channel protocols like Tree-based Multi-Channel, Multi-Channel MAC and Multi-frequency Media Access Control for wireless sensor networks. Results indicate CMSP has higher throughput and data delivery ratio at a lower power consumption due to network partitioning and hierarchical scheduling that minimizes load on the network.

  15. Salt Intrusion, Tides and Mixing in Multi-channel Estuaries

    NARCIS (Netherlands)

    Nguyen, A.D.

    2008-01-01

    Multi-channel estuaries, such as the Mekong Delta in Vietnam and the Scheldt in the Netherlands, have characteristics of both the river and the sea, forming a unique environment influenced by tidal movements of the sea and freshwater flow of the river. This study addresses a number of knowledge gaps

  16. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  17. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  18. The Art of Multi-channel Hypermedia Application Development

    NARCIS (Netherlands)

    Synodinos, Dionysios G.; Avgeriou, Paris

    2003-01-01

    The plethora of networked devices and platforms that continuously come to light, as well as the emergence of alternative ways to access the internet, have increased the demand for multi-channel access to hypermedia applications. Researchers and practitioners nowadays not only have to deal with the

  19. Recent advances in Multi-Channel Algebraic Scattering

    International Nuclear Information System (INIS)

    Karataglidis, S.; Fraser, P. R.; Amos, K.; Canton, L.; Pisent, G.; Svenne, J. P.; Knijff, D. van der

    2011-01-01

    For coupled-channel descriptions of low-energy nucleon-induced interactions involving nuclei with particle-unstable exited states, it is necessary to include the widths of the target states. How those widths may affect the elastic scattering cross sections is examined within the framework of the Multi-Channel Algebraic Scattering (MCAS) method.

  20. Multi-channel service concept design and prototyping

    NARCIS (Netherlands)

    Sperling, C.P.; Simons, L.P.A.; Bouwman, W.A.G.A.

    2007-01-01

    Designing e-services which have to function in a multi-channel context has proved to be challenging for organizations. Previous research has shown that structured design methods are useful to structure the design process. In this paper we proceed from an existing method (which identifies

  1. Superior Canal Dehiscence Syndrome: Lessons from the First 20 Years

    Directory of Open Access Journals (Sweden)

    Bryan K. Ward

    2017-04-01

    Full Text Available Superior semicircular canal dehiscence syndrome was first reported by Lloyd Minor and colleagues in 1998. Patients with a dehiscence in the bone overlying the superior semicircular canal experience symptoms of pressure or sound-induced vertigo, bone conduction hyperacusis, and pulsatile tinnitus. The initial series of patients were diagnosed based on common symptoms, a physical examination finding of eye movements in the plane of the superior semicircular canal when ear canal pressure or loud tones were applied to the ear, and high-resolution computed tomography imaging demonstrating a dehiscence in the bone over the superior semicircular canal. Research productivity directed at understanding better methods for diagnosing and treating this condition has substantially increased over the last two decades. We now have a sound understanding of the pathophysiology of third mobile window syndromes, higher resolution imaging protocols, and several sensitive and specific diagnostic tests. Furthermore, we have a treatment (surgical occlusion of the superior semicircular canal that has demonstrated efficacy. This review will highlight some of the fundamental insights gained in SCDS, propose diagnostic criteria, and discuss future research directions.

  2. Multi-channel temperature measurement system for automotive battery stack

    Science.gov (United States)

    Lewczuk, Radoslaw; Wojtkowski, Wojciech

    2017-08-01

    A multi-channel temperature measurement system for monitoring of automotive battery stack is presented in the paper. The presented system is a complete battery temperature measuring system for hybrid / electric vehicles that incorporates multi-channel temperature measurements with digital temperature sensors communicating through 1-Wire buses, individual 1-Wire bus for each sensor for parallel computing (parallel measurements instead of sequential), FPGA device which collects data from sensors and translates it for CAN bus frames. CAN bus is incorporated for communication with car Battery Management System and uses additional CAN bus controller which communicates with FPGA device through SPI bus. The described system can parallel measure up to 12 temperatures but can be easily extended in the future in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.

  3. Multi-channel fiber optic dew and humidity sensor

    Science.gov (United States)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  4. Mimicking multi-channel scattering with single-channel approaches

    OpenAIRE

    Grishkevich, Sergey; Schneider, Philipp-Immanuel; Vanne, Yulian V.; Saenz, Alejandro

    2009-01-01

    The collision of two atoms is an intrinsic multi-channel (MC) problem as becomes especially obvious in the presence of Feshbach resonances. Due to its complexity, however, single-channel (SC) approximations, which reproduce the long-range behavior of the open channel, are often applied in calculations. In this work the complete MC problem is solved numerically for the magnetic Feshbach resonances (MFRs) in collisions between generic ultracold 6Li and 87Rb atoms in the ground state and in the ...

  5. Multi-channel imaging cytometry with a single detector

    Science.gov (United States)

    Locknar, Sarah; Barton, John; Entwistle, Mark; Carver, Gary; Johnson, Robert

    2018-02-01

    Multi-channel microscopy and multi-channel flow cytometry generate high bit data streams. Multiple channels (both spectral and spatial) are important in diagnosing diseased tissue and identifying individual cells. Omega Optical has developed techniques for mapping multiple channels into the time domain for detection by a single high gain, high bandwidth detector. This approach is based on pulsed laser excitation and a serial array of optical fibers coated with spectral reflectors such that up to 15 wavelength bins are sequentially detected by a single-element detector within 2.5 μs. Our multichannel microscopy system uses firmware running on dedicated DSP and FPGA chips to synchronize the laser, scanning mirrors, and sampling clock. The signals are digitized by an NI board into 14 bits at 60MHz - allowing for 232 by 174 pixel fields in up to 15 channels with 10x over sampling. Our multi-channel imaging cytometry design adds channels for forward scattering and back scattering to the fluorescence spectral channels. All channels are detected within the 2.5 μs - which is compatible with fast cytometry. Going forward, we plan to digitize at 16 bits with an A-toD chip attached to a custom board. Processing these digital signals in custom firmware would allow an on-board graphics processing unit to display imaging flow cytometry data over configurable scanning line lengths. The scatter channels can be used to trigger data buffering when a cell is present in the beam. This approach enables a low cost mechanically robust imaging cytometer.

  6. Coordinating Multi-Channel Pricing of Seasonal Goods

    OpenAIRE

    Preetam Basu

    2012-01-01

    Advancement in information technology has opened new avenues for traditional retailers to expand their operations. Pricing, which has been a critical issue, is more important than ever before as traditional retailers pursue multi-channel sales. In this paper the author studies the pricing problem of a retailer selling a seasonal product simultaneously in a ‘brick and mortar’ store as well as online. Optimal prices are derived and different product-market conditions are determined under wh...

  7. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Muller, F; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The implementation of the signal generator is presented as well as an application where it was successfully utilized.

  8. A Low-cost Multi-channel Analogue Signal Generator

    CERN Document Server

    Müller, F; The ATLAS collaboration; Shen, W; Stamen, R

    2009-01-01

    A scalable multi-channel analogue signal generator is presented. It uses a commercial low-cost graphics card with multiple outputs in a standard PC as signal source. Each color signal serves as independent channel to generate an analogue signal. A custom-built external PCB was developed to adjust the graphics card output voltage levels for a specific task, which needed differential signals. The system furthermore comprises a software package to program the signal shape. The signal generator was successfully used as independent test bed for the ATLAS Level-1 Trigger Pre-Processor, providing up to 16 analogue signals.

  9. Empirical Study on Multi-Channel Service Quality and Customer Loyalty of Retailers

    OpenAIRE

    Qi Yong-zhi

    2014-01-01

    This paper studies the influence of offline RSSQ (retailing store service quality), online store ESQ (E-service quality) and O2O MCISQ (multi-channel integration service quality) on traditional retailers' customer loyalty as well as the relation of them three in multi-channel retailing. 380 customers with both offline and online shopping experience at the same retailer's store are investigated. Through the structural equation model, we find out that in multi-channel retailing, RSSQ and MCISQ ...

  10. Anatomy of the lamprey ear: morphological evidence for occurrence of horizontal semicircular ducts in the labyrinth of Petromyzon marinus

    Science.gov (United States)

    Maklad, Adel; Reed, Caitlyn; Johnson, Nicholas S.; Fritzsch, Bernd

    2014-01-01

    In jawed (gnathostome) vertebrates, the inner ears have three semicircular canals arranged orthogonally in the three Cartesian planes: one horizontal (lateral) and two vertical canals. They function as detectors for angular acceleration in their respective planes. Living jawless craniates, cyclostomes (hagfish and lamprey) and their fossil records seemingly lack a lateral horizontal canal. The jawless vertebrate hagfish inner ear is described as a torus or doughnut, having one vertical canal, and the jawless vertebrate lamprey having two. These observations on the anatomy of the cyclostome (jawless vertebrate) inner ear have been unchallenged for over a century, and the question of how these jawless vertebrates perceive angular acceleration in the yaw (horizontal) planes has remained open. To provide an answer to this open question we reevaluated the anatomy of the inner ear in the lamprey, using stereoscopic dissection and scanning electron microscopy. The present study reveals a novel observation: the lamprey has two horizontal semicircular ducts in each labyrinth. Furthermore, the horizontal ducts in the lamprey, in contrast to those of jawed vertebrates, are located on the medial surface in the labyrinth rather than on the lateral surface. Our data on the lamprey horizontal duct suggest that the appearance of the horizontal canal characteristic of gnathostomes (lateral) and lampreys (medial) are mutually exclusive and indicate a parallel evolution of both systems, one in cyclostomes and one in gnathostome ancestors.

  11. Multi-channel grouping techniques for conducting reactor safety studies

    International Nuclear Information System (INIS)

    Waltar, A.E.; Wilburn, N.P.

    1975-01-01

    In conducting safety studies for postulated unprotected accidents in an LMFBR system, it is common practice to employ multi-channel coupled neutronics, thermal hydraulics computer programs such as SAS3A or MELT-III. The multichannel feature of such code systems is important if the natural fuel failure incoherencies and the resulting sodium void/fuel motion reactivity feedbacks--which have strong spatial variations--are to be properly modeled. Because of the large amounts of computer time associated with many channel runs, however, there is a strong incentive to conduct parametric studies with as few channels as possible. The paper presented is focused on methods successfully employed to accomplish this end for a study of the hypothetical unprotected transient overpower accident conducted for the FFTF

  12. Multi-channel bolometer system on JFT-2M tokamak

    International Nuclear Information System (INIS)

    Tamai, Hiroshi; Maeno, Masaki; Matsuda, Toshiaki; Matoba, Tohru

    1988-07-01

    Multi-channel bolometer system is designed and installed to observe the radiation profile on JFT-2M tokamak. Sensor head is made of Thinistor, which is a kind of semiconductor, because it has the advantage of higher sensitivity of about one order of magnitude than the conventional metal foil bolometer and is suitable for the profile measurement in which the signal from the plasma is relatively small. The response and cooling characteristics of the bolometer sensor are suitable for the condition of JFT-2M tokamak plasma. Low noise circuit of bridge and differentiator is developed to optimize the signal to noise ratio in the JFT-2M operating condition. With use of the bolometer system, the radiation profile in joule heating plasma as well as additional heating plasma especially in H-mode plasma is successfully observed. (author)

  13. Multi-channel unidirectional transmission of phononic crystal heterojunctions

    Science.gov (United States)

    Xu, Zhenlong; Tong, Jie; Wu, Fugen

    2018-02-01

    Two square steel columns are arranged in air to form two-dimensional square lattice phononic crystals (PNCs). Two PNCs can be combined into a non-orthogonal 45∘ heterojunction when the difference in the directional band gaps of the two PNC types is utilized. The finite element method is used to calculate the acoustic band structure, the heterogeneous junction transmission characteristics, acoustic field distribution, and many others. Results show that a non-orthogonal PNC heterojunction can produce a multi-channel unidirectional transmission of acoustic waves. With the square scatterer rotated, the heterojunction can select a frequency band for unidirectional transmission performance. This capability is particularly useful for constructing acoustic diodes with wide-bands and high-efficiency unidirectional transmission characteristics.

  14. New ultra small battery operated portable multi-channel analyzer

    International Nuclear Information System (INIS)

    Wolf, M.A.; Umbarger, C.J.

    1979-01-01

    A newly designed portable multi-channel analyzer (MCA) has been developd at Los Alamos that has much improved physical and performance characteristics over previous designs. Namely, the instrument is very compact (25 cm wide x 14 cm deep x 21 cm high) and has a mass of 4.2 Kg (9.2 lb). The device has 1024 channels and is microprocessor controlled. The instrument has most of the standard features of present laboratory-based pulse height analyzers, including CRT display, region of interest integration, etc. Battery life of the MCA is nearly eight hours, with full charging over night. An accessory case carries a small audio cassette recorder for data storage. The case also contains two different NaI(Tl) detectors

  15. Miniaturized multi channel infrared optical gas sensor system

    Science.gov (United States)

    Wöllenstein, Jürgen; Eberhardt, Andre; Rademacher, Sven; Schmitt, Katrin

    2011-06-01

    Infrared spectroscopy uses the characteristic absorption of the molecules in the mid infrared and allows the determination of the gases and their concentration. Especially by the absorption at longer wavelengths between 8 μm and 12 μm, the so called "fingerprint" region, the molecules can be measured with highest selectivity. We present an infrared optical filter photometer for the analytical determination of trace gases in the air. The challenge in developing the filter photometer was the construction of a multi-channel system using a novel filter wheel concept - which acts as a chopper too- in order to measure simultaneously four gases: carbon monoxide, carbon dioxide, methane and ammonia. The system consists of a broadband infrared emitter, a long path cell with 1.7m optical path length, a filter wheel and analogue and digital signal processing. Multi channel filter photometers normally need one filter and one detector per target gas. There are small detection units with one, two or more detectors with integrated filters available on the market. One filter is normally used as reference at a wavelength without any cross-sensitivities to possible interfering gases (e.g. at 3.95 μm is an "atmospheric window" - a small spectral band without absorbing gases in the atmosphere). The advantage of a filter-wheel set-up is that a single IR-detector can be used, which reduces the signal drift enormously. Pyroelectric and thermopile detectors are often integrated in these kinds of spectrometers. For both detector types a modulation of the light is required and can be done - without an additional chopper - with the filter wheel.

  16. Determination of optimum "multi-channel surface wave method" field parameters.

    Science.gov (United States)

    2012-12-01

    Multi-channel surface wave methods (especially the multi-channel analyses of surface wave method; MASW) are routinely used to : determine the shear-wave velocity of the subsurface to depths of 100 feet for site classification purposes. Users are awar...

  17. Assessment of the effects of superior canal dehiscence location and size on intracochlear sound pressures

    NARCIS (Netherlands)

    Niesten, Marlien E F; Stieger, Christof; Lee, Daniel J; Merchant, Julie P; Grolman, Wilko; Rosowski, John J; Nakajima, Hideko Heidi

    2015-01-01

    Superior canal dehiscence (SCD) is a defect in the bony covering of the superior semicircular canal. Patients with SCD present with a wide range of symptoms, including hearing loss, yet it is unknown whether hearing is affected by parameters such as the location of the SCD. Our previous human

  18. Multi-channel Analysis of Passive Surface Waves (MAPS)

    Science.gov (United States)

    Xia, J.; Cheng, F. Mr; Xu, Z.; Wang, L.; Shen, C.; Liu, R.; Pan, Y.; Mi, B.; Hu, Y.

    2017-12-01

    Urbanization is an inevitable trend in modernization of human society. In the end of 2013 the Chinese Central Government launched a national urbanization plan—"Three 100 Million People", which aggressively and steadily pushes forward urbanization. Based on the plan, by 2020, approximately 100 million people from rural areas will permanently settle in towns, dwelling conditions of about 100 million people in towns and villages will be improved, and about 100 million people in the central and western China will permanently settle in towns. China's urbanization process will run at the highest speed in the urbanization history of China. Environmentally friendly, non-destructive and non-invasive geophysical assessment method has played an important role in the urbanization process in China. Because human noise and electromagnetic field due to industrial life, geophysical methods already used in urban environments (gravity, magnetics, electricity, seismic) face great challenges. But humanity activity provides an effective source of passive seismic methods. Claerbout pointed out that wavefileds that are received at one point with excitation at the other point can be reconstructed by calculating the cross-correlation of noise records at two surface points. Based on this idea (cross-correlation of two noise records) and the virtual source method, we proposed Multi-channel Analysis of Passive Surface Waves (MAPS). MAPS mainly uses traffic noise recorded with a linear receiver array. Because Multi-channel Analysis of Surface Waves can produces a shear (S) wave velocity model with high resolution in shallow part of the model, MPAS combines acquisition and processing of active source and passive source data in a same flow, which does not require to distinguish them. MAPS is also of ability of real-time quality control of noise recording that is important for near-surface applications in urban environment. The numerical and real-world examples demonstrated that MAPS can be

  19. Qualitative analysis of the Dix-Hallpike maneuver in multi-canal BPPV using a biomechanical model: Introduction of an expanded Dix-Hallpike maneuver for enhanced diagnosis of multi-canal BPPV

    Directory of Open Access Journals (Sweden)

    Henri Traboulsi

    2017-09-01

    Conclusion: The Dix–Hallpike maneuver may cause simultaneous movement of otoliths present in multiple canals and create an obstacle to accurate diagnosis in multi-canal BPPV. An expanded Dix-Hallpike maneuver is described which adds intermediate steps with the head positioned to the right and left in the horizontal position before head-hanging. This expanded maneuver has helped to isolate affected semi-circular canals for individual assessment in multiple canal BPPV.

  20. Microcontroller based multi-channel ultrasonic level monitoring system

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Singh, Inder Jeet; Chadda, V.K.

    2004-01-01

    Microcontroller based Multi-channel Ultrasonic Level Monitoring System developed by Computer Division is based on echo ranging techniques to monitor level. The transmitter directs an ultrasonic burst towards the liquid, which gets reflected from the top of the liquid surface. The time taken for ultrasound to travel from the transmitter to the top of liquid surface is measured and used to calculate the liquid level. The system provides for temperature compensation for accurate measurement as the ultrasound velocity depends on the ambient temperature. It can measure liquid level up to 5 meters. A single monitor can be used to measure level in 6 tanks. PC connectivity has been provided via RS 232 and RS 485 for remote operation and data logging of level. A GUI program developed using LABVIEW package displays level on PC monitor. The program provides for pictorial as well as numerical display for level and temperature in the front panel on the PC monitor. A user can monitor level for any or all tanks from the PC. One unit is installed at CIRUS for measuring level in Acid/ Alkali tanks and one is installed at APSARA for measuring water level in the reactor pool. (author)

  1. Dynamic multi-channel TMS with reconfigurable coil.

    Science.gov (United States)

    Jiang, Ruoli; Jansen, Ben H; Sheth, Bhavin R; Chen, Ji

    2013-05-01

    Investigations of the causal involvement of particular brain areas and interconnections in behavior require an external stimulation system with reasonable spatio-temporal resolution. Current transcranial magnetic stimulation (TMS) technology is limited to stimulating a single brain area once in a given trial. Here, we present a feasibility study for a novel TMS system based on multi-channel reconfigurable coils. With this hardware, researchers will be able to stimulate multiple brain sites in any temporal order in a trial. The system employs a wire-mesh coil, constructed using x- and y-directional wires. By varying the current direction and/or strength on each wire, we can configure the proposed mesh-wire coil into a standard loop coil and figure-eight coil of varying size. This provides maximum flexibility to the experimenter in that the location and extent of stimulation on the brain surface can be modified depending on experimental requirement. Moreover, one can dynamically and automatically modify the site(s) of stimulation several times within the span of seconds. By pre-storing various sequences of excitation patterns inside a control unit, one can explore the effect of dynamic TMS on behavior, in associative learning, and as rehabilitative therapy. Here, we present a computer simulation and bench experiments that show the feasibility of the dynamically-reconfigurable coil.

  2. A multi-channel AC power supply controller

    International Nuclear Information System (INIS)

    Su Hong; Li Xiaogang; Ma Xiaoli; Zhou Bo; Yin Weiwei

    2003-01-01

    A multi-channel ac power supply controller developed recently by authors is introduced briefly in this paper. This controller is a computer controlled multi-electronic-switch device. This controller was developed for the automatic control and monitoring system of a 220 V ac power supply system, it is a key front-end device of the automatic control and monitoring system. There is an electronic switch in each channel, the rated load power is ≤1 kW/each channel. Another function is to sample the 220 V ac output voltage so that computer can monitor the operation state of each electronic switch. Through these switches, the 220 V ac power supply is applied to some device or apparatus that need to be powered by 220 V ac power supply. In the design, a solid-state relay was employed as an electronic switch. This controller can be connected in cascade mode. There are 8 boxes at most can be connected in cascade mode. The length of control word is 8 bit, which contains addressing information and electronic switch state setting information. The sampling output of the controller is multiplexed. It is only one bit that indicates the operating state of an electronic switch. This controller has been used in an automatic control and monitoring system for 220 V ac power supply system

  3. A multi-channel stakeholder consultation process for transmission deregulation

    International Nuclear Information System (INIS)

    Gregory, Robin; Fischhoff, Baruch; Thorne, Sarah; Butte, Gordon

    2003-01-01

    Deregulating Ontario's energy market required designing a rate structure for transmission costs that previously had been bundled with other electricity services. The Ontario Hydro Networks Company (now called Hydro One Networks, or 'Hydro One') owns and operates the transmission lines. It sought input from a full spectrum of stakeholders in preparing a proposed rate structure for submission to the regulator, the Ontario Energy Board (OEB). Securing that input meant accommodating great differences in stakeholders' familiarity with the (often highly technical) issues of rate setting. Hydro One drew on recent developments in stakeholder processes, integrated assessment, and risk communication to create a multi-channel process for eliciting and responding to stakeholder input. That process included (a) detailed background documents, (b) dedicated briefings and workshops, (c) mental models interviews, (d) focused meetings, and (e) mail (and email) boxes. The process was coordinated with a formal expert model, summarizing the factors determining the multiple impacts of the rate structure and the regulatory process producing it. The model analyzed these impacts, structured communications, and organized inputs, in a comprehensive and coherent way. This process facilitated developing proposals that were both technically sound and widely accepted by stakeholders, including the OEB. The case study provides a model for addressing other problems requiring stakeholder input on complex technical issues. It contrasts with other consultative processes with a less formal structure for eliciting concerns, less ability to encourage learning, and greater emphasis on achieving consensus

  4. Multi-Channel Data Recording of Marx switch closures

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Ruggles, L.E.; Ziska, G.R.

    1984-01-01

    The authors have measured the optical signals associated with switch closure on the Demon marx at Sandia National Laboratories. Using the High Speed Multi-Channel Data Recorder(HSMCDR), they have recorded the time histories of the optical signals from the thirty switches in the marx generator. All thirty switches were fiber connected to the HSMCDR. The HSMCDR consists of a high speed streak camera, and a microcomputer-based video digitizing system. Since the thirty signals are recorded on a single streak, the time sequence can be determined with great accuracy. The appearance of a given signal can be determined to within two samples of the 256 samples that make up the time streak. The authors have found that the light intensity and time history of any given switch varied over a large range from shot to shot. Thus, the ability to record the entire optical signal as a function of time for each switch on every shot is necessary if accurate timing results are required

  5. Use of trapezoidal shaping algorithm in the digital multi-channel system

    International Nuclear Information System (INIS)

    Wang Jihong; Wang Lianghou; Fang Zongliang

    2011-01-01

    It discusses one kind of digital filter technology-trapezoidal algorithm based on actual need of studying the digital multi-channel. Firstly, demonstrating the feasibility of the arithmetic with theoretical analysis; secondly, predigesting the process of the arithmetic; thirdly, simulating with MATLAB; lastly, using the arithmetic to measure data. The result of testing indicates trapezoidal shaping algorithm accords with the need of digital multi-channel shaping extraordinary. The best filter can be obtained by means of setting parameter due to superiority of digital multi-channel. (authors)

  6. Radioanatomy of the singular nerve canal

    Energy Technology Data Exchange (ETDEWEB)

    Muren, C. [Dept. of Diagnostic Radiology, Sabbatsbergs Hospital, Stockholm (Sweden); Wadin, K. [University Hospital, Uppsala (Sweden); Dimopoulos, P. [University Hospital, Uppsala (Sweden)

    1991-08-01

    The singular canal conveys vestibular nerve fibers from the ampulla of the posterior semicircular canal to the posteroinferior border of the internal auditory meatus. Radiographic identification of this anatomic structure helps to distinguish it from a fracture. It is also a landmark in certain surgical procedures. Computed tomography (CT) examinations of deep-frozen temporal bone specimens were compared with subsequently prepared plastic casts of these bones, showing good correlation between the anatomy and the images. The singular canal and its variable anatomy were studied in CT examinations of 107 patients. The singular canal could be identified, in both the axial and in the coronal planes. Its point of entry into the internal auditory meatus varied considerably. (orig.)

  7. Integrated multi-channel vehicle-vehicle and vehicle-roadside communications for ITS

    Science.gov (United States)

    2008-12-01

    This research describes a medium access control (MAC) protocol to Enable multi-channel operation for dedicated short-range communication (DSRC). In particular, we focus on the challenge of supporting potentially high-bandwidth commercial or infotainm...

  8. EDMC: An enhanced distributed multi-channel anti-collision algorithm for RFID reader system

    Science.gov (United States)

    Zhang, YuJing; Cui, Yinghua

    2017-05-01

    In this paper, we proposes an enhanced distributed multi-channel reader anti-collision algorithm for RFID environments which is based on the distributed multi-channel reader anti-collision algorithm for RFID environments (called DiMCA). We proposes a monitor method to decide whether reader receive the latest control news after it selected the data channel. The simulation result shows that it improves interrogation delay.

  9. JADSPE, Multi-Channel Gamma Spectra Unfolding Program

    International Nuclear Information System (INIS)

    Rikovska, J.; Stejskalova, E.

    2005-01-01

    1 - Description of program or function: JADSPE is a package of eight programs to process multi-channel gamma-ray spectra. The programs can be used to: - locate automatically spectral peaks and calculate their positions, areas, and full widths at half maximum (FWHM); - plot the spectra on a CALCOMP plotter, TEKTRONIX terminal or a line printer; - add or subtract several spectra with the possibility of adjusting either their start and end channels or the maxima of the chosen corresponding peaks. The JADSPE package comprises the following programs: - SPECTF: automatic location of peaks and calculation of their positions, areas and FWHMS. The standard deviations of peak parameters are also determined, and each evaluated region is plotted on the line printer. - SPECT1: The areas and FWHMs are calculated for peaks whose positions are known beforehand. The standard deviations of calculated parameters are also determined, and each evaluated region is plotted on the line printer. - PLOCHA: The peak net area is calculated by summing the channel contents in specified regions and by subtracting a linear background. - GRAPH: Spectrum plotting on the line printer. - PLTNEW: Spectrum plotting on CALCOMP plotter or on TEKTRONIX terminal. - SUMDIF: The channel contents of several gamma-ray spectra are added or subtracted. - SSPFP: The channel contents of several gamma-ray spectra are added with adjustment of the maxima of specified peaks. - SOUCET: The channel contents of several gamma-ray spectra are added with the adjustment of start and end channels of the spectra. 2 - Method of solution: Non-linear least-square fit. 3 - Restrictions on the complexity of the problem: The full energy peaks are approximated by a symmetrical Gaussian function and the underlying background is approximated by a first-order polynomial. A fixed spectrum length of 4096 channels is assumed. Maxima of: - number of peaks in one multiplet: 9; - number of peaks identified by the automatic search procedure

  10. Multi-channel motor evoked potential monitoring during anterior cervical discectomy and fusion

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objectives: Anterior cervical discectomy and fusion (ACDF surgery is the most common surgical procedure for the cervical spine with low complication rate. Despite the potential prognostic benefit, intraoperative neurophysiological monitoring (IONM, a method for detecting impending neurological compromise, is not routinely used in ACDF surgery. The present study aimed to identify the potential benefits of monitoring multi-channel motor evoked potentials (MEPs during ACDF surgery. Methods: We retrospectively reviewed 200 consecutive patients who received IONM with multi-channel MEPs and somatosensory evoked potentials (SSEPs. On average, 9.2 muscles per patient were evaluated under MEP monitoring. Results: The rate of MEP change during surgery in the multi-level ACDF group was significantly higher than the single-level group. Two patients from the single-level ACDF group (1.7% and four patients from the multi-level ACDF group (4.9% experienced post-operative motor deficits. Multi-channel MEPs monitoring during single and multi-level ACDF surgery demonstrated higher sensitivity, specificity, positive predictive and negative predictive value than SSEP monitoring. Conclusions: Multi-channel MEP monitoring might be beneficial for the detection of segmental injury as well as long tract injury during single- and multi-level ACDF surgery. Significance: This is first large scale study to identify the usefulness of multi-channel MEPs in monitoring ACDF surgery. Keywords: Disc disease, Somatosensory evoked potentials, Intraoperative neurophysiological monitoring, Motor evoked potentials, Anterior cervical discectomy and fusion

  11. Otolith and canal reflexes in human standing

    Science.gov (United States)

    Cathers, Ian; Day, Brian L; Fitzpatrick, Richard C

    2005-01-01

    We used galvanic vestibular stimulation (GVS) to identify human balance reflexes of the semicircular canals and otolith organs. The experiment used a model of vestibular signals arising from GVS modulation of the net signal from vestibular afferents. With the head upright, the model predicts that the GVS-evoked canal signal indicates lateral head rotation while the otolith signal indicates lateral tilt or acceleration. Both signify body sway transverse to the head. With the head bent forward, the model predicts that the canal signal indicates body spin about a vertical axis but the otolith signal still signifies lateral body motion. Thus, we compared electromyograms (EMG) in the leg muscles and body sway evoked by GVS when subjects stood with the head upright or bent forward. With the head upright, GVS evoked a large sway in the direction of the anodal electrode. This response was abolished with the head bent forward leaving only small, oppositely directed, transient responses at the start and end of the stimulus. With the head upright, GVS evoked short-latency (60–70 ms), followed by medium-latency (120 ms) EMG responses, of opposite polarity. Bending the head forward abolished the medium-latency but preserved the short-latency response. This is compatible with GVS evoking separate otolithic and canal reflexes, indicating that balance is controlled by independent canal and otolith reflexes, probably through different pathways. We propose that the short-latency reflex and small transient sway are driven by the otolith organs and the medium-latency response and the large sway are driven by the semicircular canals. PMID:15618274

  12. The Time Division Multi-Channel Communication Model and the Correlative Protocol Based on Quantum Time Division Multi-Channel Communication

    International Nuclear Information System (INIS)

    Liu Xiao-Hui; Pei Chang-Xing; Nie Min

    2010-01-01

    Based on the classical time division multi-channel communication theory, we present a scheme of quantum time-division multi-channel communication (QTDMC). Moreover, the model of quantum time division switch (QTDS) and correlative protocol of QTDMC are proposed. The quantum bit error rate (QBER) is analyzed and the QBER simulation test is performed. The scheme shows that the QTDS can carry out multi-user communication through quantum channel, the QBER can also reach the reliability requirement of communication, and the protocol of QTDMC has high practicability and transplantable. The scheme of QTDS may play an important role in the establishment of quantum communication in a large scale in the future. (general)

  13. Software filtering method to suppress spike pulse interference in multi-channel scaler

    International Nuclear Information System (INIS)

    Huang Shun; Zhao Xiuliang; Li Zhiqiang; Zhao Yanhui

    2008-01-01

    In the test on anti-jamming function of a multi-channel scaler, we found that the spike pulse interference on the second level counter caused by the motor start-stop operations brings a major count error. There are resolvable characteristics between effective signal and spike pulse interference, and multi-channel hardware filtering circuit is too huge and can't filter thoroughly, therefore we designed a software filtering method. In this method based on C8051F020 MCU, we dynamically store sampling values of one channel in only a one-byte variable and distinguish the rise-trail edge of a signal and spike pulse interference because of value changes of the variable. Test showed that the filtering software method can solve the error counting problem of the multi-channel scaler caused by the motor start-stop operations. The flow chart and source codes of the method were detailed in this paper. (authors)

  14. A multi-channel isolated power supply in non-equipotential circuit

    Science.gov (United States)

    Li, Xiang; Zhao, Bo-Wen; Zhang, Yan-Chi; Xie, Da

    2018-04-01

    A multi-channel isolation power supply is designed for the problems of different MOSFET or IGBT in the non-equipotential circuit in this paper. It mainly includes the square wave generation circuit, the high-frequency transformer and the three-terminal stabilized circuit. The first part is used to generate the 24V square wave, and as the input of the magnetic ring transformer. In the second part, the magnetic ring transformer consists of one input and three outputs to realize multi-channel isolation output. The third part can output different potential and realize non-equal potential function through the three-terminal stabilized chip. In addition, the multi-channel isolation power source proposed in this paper is Small size, high reliability and low price, and it is convenient for power electronic switches that operate on multiple different potentials. Therefore, the research on power supply of power electronic circuit has practical significance.

  15. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  16. Development of multi-channel gated integrator and PXI-DAQ system for nuclear detector arrays

    International Nuclear Information System (INIS)

    Kong Jie; Su Hong; Chen Zhiqiang; Dong Chengfu; Qian Yi; Gao Shanshan; Zhou Chaoyang; Lu Wan; Ye Ruiping; Ma Junbing

    2010-01-01

    A multi-channel gated integrator and PXI based data acquisition system have been developed for nuclear detector arrays with hundreds of detector units. The multi-channel gated integrator can be controlled by a programmable GI controller. The PXI-DAQ system consists of NI PXI-1033 chassis with several PXI-DAQ cards. The system software has a user-friendly GUI which is written in C language using LabWindows/CVI under Windows XP operating system. The performance of the PXI-DAQ system is very reliable and capable of handling event rate up to 40 kHz.

  17. A multi-channel humidity control system based on LabVIEW

    International Nuclear Information System (INIS)

    Zhang Aiwu; Xie Yuguang; Liu Hongbang; Liu Yingbiao; Cai Xiao; Yu Boxiang; Lu Junguang; Zhou Li

    2011-01-01

    A real time multi-channel humidity control system was designed based on LabVIEW, using the dry air branch of BESⅢ drying system. The hardware of this control system consist of mini humidity and temperature sensors, intelligent collection module, switch quantity controller and electromagnetic valves. The humidity can be controlled at arbitrary value from air humidity to 3% with accuracy better than 2%. Multi microenvironment with different humidity can be easily controlled and monitored in real time by this system. It can also be extended to hybrid control of multi channel humidity and temperature. (authors)

  18. Multi-channel spintronic transistor design based on magnetoelectric barriers and spin-orbital effects

    International Nuclear Information System (INIS)

    Fujita, T; Jalil, M B A; Tan, S G

    2008-01-01

    We present a spin transistor design based on spin-orbital interactions in a two-dimensional electron gas, with magnetic barriers induced by a patterned ferromagnetic gate. The proposed device overcomes certain shortcomings of previous spin transistor designs such as long device length and degradation of conductance modulation for multi-channel transport. The robustness of our device for multi-channel transport is unique in spin transistor designs based on spin-orbit coupling. The device is more practical in fabrication and experimental respects compared to previously conceived single-mode spin transistors

  19. The design and implementation of a PC based multi-channel scaler system

    International Nuclear Information System (INIS)

    Wang Qiang; Chinese Academy of Sciences, Beijing; Jin Dapeng; Liu Zhen'an; Zhao Dixin

    2007-01-01

    A multi-channel scaler system is designed for the system check and status monitoring of the BESIII trigger system. It is composed of a PC, two PCI interface multi-channel scaler cards, the corresponding drivers and user programs. Total 64 signals can be scaled and monitored in real time. The scaled data are recorded locally and some of them are distributed to the online system. In this paper, the hardware structure, software development and long time running stability of the system are introduced. (authors)

  20. The development of 128 ch fast multi channel pulse height analyzer for a tokamak plasmas

    International Nuclear Information System (INIS)

    Kawashima, Hisato; Matoba, Tohru; Ogawa, Toshihide; Kawakami, Tomohide

    1985-02-01

    A high counting rate multi channel pulse height analyzer was developed and tested to measure the detailed time evolution of X-ray energy spectrun radiated from a tokamak plasmas. Main developing objects of this analyzer are as follows. 1. The maximum counting rate and the minimum time resolution are 4 Mcps and 10 ms, respectively. 2. The energy resolution has ability to distinguish the characterisitic X-ray line. 3. Computer has to be used for operating system. This fast multi channel analyzer is using to measure the Soft X-ray spectrum on JFT-2M tokamak, and is confirmed to be useful for a practical measuring system. (author)

  1. New-fashioned Multi-channel Analyzer Based on Bipartition Method

    International Nuclear Information System (INIS)

    Liu Mingjian; Zhang Yan; Yan Xuekun; Chen Ying

    2009-01-01

    A new-fashioned digital-analog converter (DAC) which can find the pulse-signal amplitude through dichotomy is devised. With this new DAC method, a 256-channel multi-channel pulse amplitude analyzer (MCA) is designed successfully, and its hardware and software are introduced in detail. This provides a new method for designing MCA. (authors)

  2. Personalized multi-channel headphone sound reproduction based on active noise cancellation

    NARCIS (Netherlands)

    Schobben, D.W.E.; Aarts, R.M.

    2005-01-01

    A system for headphone signal processing is discussed which gives a listener the same impression as listening to a multi-channel loudspeaker set-up. It is important that this processing is optimized for each individual listener. If this is not the case, large localization errors may occur. In the

  3. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized through- put maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  4. Autonomous transmission power adaptation for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2008-09-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in WMNs. Previous studies have emphasized throughput maximization in such systems as the main design challenge and transmission power control treated as a secondary issue...

  5. Multiple-state based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-01-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in wireless mesh networks (WMNs). In this paper, we present asynchronous multiple-state based power control for MRMC WMNs. First, WMN is represented as a set of disjoint...

  6. E-Fulfillment and Multi-Channel Distribution – A Review

    NARCIS (Netherlands)

    N.A.H. Agatz (Niels); M. Fleischmann (Moritz); J.A.E.E. van Nunen (Jo)

    2006-01-01

    textabstractThis review addresses the specific supply chain management issues of Internet fulfillment in a multi-channel environment. It provides a systematic overview of managerial planning tasks and reviews corresponding quantitative models. In this way, we aim to enhance the understanding of

  7. Exploiting the opportunities of Internet and multi-channel pricing : An exploratory research

    NARCIS (Netherlands)

    Sotgiu, Francesca; Ancarani, Fabio

    2004-01-01

    Smart firms are not worried about the impact of the Internet on pricing, but realise that they have the unique opportunity to exploit new options and improve their marketing performance. Multi-channel pricing is one of the most interesting opportunities firms can exploit in the digital economy.

  8. Range based power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-08-01

    Full Text Available Multi-Radio Multi-Channel (MRMC) systems are key to power control problems in Wireless Mesh Networks (WMNs). In this paper, researchers present a range based dynamic power control for MRMC WMNs. First, WMN is represented as a set of disjoint Unified...

  9. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  10. The design of multi-channel pulse amplitude analyzer based on ARM micro controller

    International Nuclear Information System (INIS)

    Li Hai; Li Xiang; Liu Caixue

    2010-01-01

    It introduces the design of multi-channel pulse amplitude analyzer based on embedded ARM micro-controller. The embedded and real-time system μC/OS-II builds up the real-time and stability of the system and advances the integration. (authors)

  11. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  12. On the relationship between multi-channel envelope and temporal fine structure

    DEFF Research Database (Denmark)

    Søndergaard, Peter Lempel; Decorsiere, Remi Julien Blaise; Dau, Torsten

    2011-01-01

    The envelope of a signal is broadly defined as the slow changes in time of the signal, where as the temporal fine structure (TFS) are the fast changes in time, i.e. the carrier wave(s) of the signal. The focus of this paper is on envelope and TFS in multi-channel systems. We discuss the differenc...

  13. A novel portable multi-channel analyzer based on high-speed microcontroller

    International Nuclear Information System (INIS)

    Lou Xinghua; Yi Hongchang; Wang Yuemin

    2005-01-01

    This paper introduces a novel portable multi-channel analyzer (MCA) based on high-speed microcontroller. The hardware implementation and the software scenario of the MCA are discussed. The MCA has features of high speed, small size and better performances. (authors)

  14. A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Networks

    Science.gov (United States)

    2001-01-01

    00-00-2001 to 00-00-2001 4. TITLE AND SUBTITLE A Receiver-Initiated Collision-Avoidance Protocol for Multi-Channel Netowrks 5a. CONTRACT NUMBER...images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE

  15. An optimal multi-channel memory controller for real-time systems

    NARCIS (Netherlands)

    Gomony, M.D.; Akesson, K.B.; Goossens, K.G.W.

    2013-01-01

    Optimal utilization of a multi-channel memory, such as Wide IO DRAM, as shared memory in multi-processor platforms depends on the mapping of memory clients to the memory channels, the granularity at which the memory requests are interleaved in each channel, and the bandwidth and memory capacity

  16. Objective ARX Model Order Selection for Multi-Channel Human Operator Identification

    NARCIS (Netherlands)

    Roggenkämper, N; Pool, D.M.; Drop, F.M.; van Paassen, M.M.; Mulder, M.

    2016-01-01

    In manual control, the human operator primarily responds to visual inputs but may elect to make use of other available feedback paths such as physical motion, adopting a multi-channel control strategy. Hu- man operator identification procedures generally require a priori selection of the model

  17. canal24

    Data.gov (United States)

    California Natural Resource Agency — Canal system center lines in the Central Valley of California and adjacent areas captured from 1:24,000-scale USGS topographic maps. Updates and modifications made...

  18. Digital baseline estimation method for multi-channel pulse height analyzing

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun

    2005-01-01

    The basic features of digital baseline estimation for multi-channel pulse height analysis are introduced. The weight-function of minimum-noise baseline filter is deduced with functional variational calculus. The frequency response of this filter is also deduced with Fourier transformation, and the influence of parameters on amplitude frequency response characteristics is discussed. With MATLAB software, the noise voltage signal from the charge sensitive preamplifier is simulated, and the processing effect of minimum-noise digital baseline estimation is verified. According to the results of this research, digital baseline estimation method can estimate baseline optimally, and it is very suitable to be used in digital multi-channel pulse height analysis. (authors)

  19. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Science.gov (United States)

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-01-01

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction. PMID:26287193

  20. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm.

    Science.gov (United States)

    Chen, Ying-Lun; Hwang, Wen-Jyi; Ke, Chi-En

    2015-08-13

    A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO), and the feature extraction is carried out by the generalized Hebbian algorithm (GHA). To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  1. Regret of Multi-Channel Bandit Game in Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Ma Jun

    2016-01-01

    Full Text Available The problem of how to evaluate the rate of convergence to Nash equilibrium solutions in the process of channel selection under incomplete information is studied. In this paper, the definition of regret is used to reflect the convergence rates of online algorithms. The process of selecting an idle channel for each secondary user is modeled as a multi-channel bandit game. The definition of the maximal averaged regret is given. Two existing online learning algorithms are used to obtain the Nash equilibrium for each SU. The maximal averaged regrets are used to evaluate the performances of online algorithms. When there is a pure strategy Nash equilibrium in the multi-channel bandit game, the maximal averaged regrets are finite. A cooperation mechanism is also needed in the process of calculating the maximal averaged regrets. Simulation results show the maximal averaged regrets are finite and the online algorithm with greater convergence rate has less maximal averaged regrets.

  2. Multi-Channel Electronically Scanned Cryogenic Pressure Sensor And Method For Making Same

    Science.gov (United States)

    Chapman, John J. (Inventor); Hopson, Purnell, Jr. (Inventor); Holloway, Nancy M. (Inventor)

    2001-01-01

    A miniature, multi-channel, electronically scanned pressure measuring device uses electrostatically bonded silicon dies in a multi-element array. These dies are bonded at specific sites on a glass, pre-patterned substrate. Thermal data is multiplexed and recorded on each individual pressure measuring diaphragm. The device functions in a cryogenic environment without the need of heaters to keep the sensor at constant temperatures.

  3. Asymptotically exact solution of the multi-channel resonant-level model

    International Nuclear Information System (INIS)

    Zhang Guangming; Su Zhaobin; Yu Lu.

    1994-01-01

    An asymptotically exact partition function of the multi-channel resonant-level model is obtained through Tomonaga-Luttinger bosonization. A Fermi-liquid vs. non-Fermi-liquid transition, resulting from a competition between the Kondo and X-ray edge physics, is elucidated explicitly via the renormalization group theory. In the strong-coupling limit, the model is renormalized to the Toulouse limit. (author). 20 refs, 1 fig

  4. Design of multi-channel amplitude analyzer base on LonWorks

    International Nuclear Information System (INIS)

    Zhang Ying; Zhao Lihong; Chen Aihua

    2008-01-01

    The paper introduces the multi-channel analyzer which adopts LonWorks technology. The system detects the pulse peak by hardware circuits and controls data acquisition and network communication by Micro Controller and Unit and Neuron chip. SCM is programmed by Keil C51; the communication between SCM and nerve cell is realized by Neron C language, and the computer program is written by VB language. Test results show that this analyzer is with fast conversion speed and low power consumption. (authors)

  5. An integrated analog O/E/O link for multi-channel laser neurons

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, Mitchell A., E-mail: mnahmias@princeton.edu; Tait, Alexander N.; Tolias, Leonidas; Chang, Matthew P.; Ferreira de Lima, Thomas; Shastri, Bhavin J.; Prucnal, Paul R. [Electrical Engineering Department, Princeton University, 41 Olden St, Princeton, New Jersey 08540 (United States)

    2016-04-11

    We demonstrate an analog O/E/O electronic link to allow integrated laser neurons to accept many distinguishable, high bandwidth input signals simultaneously. This device utilizes wavelength division multiplexing to achieve multi-channel fan-in, a photodetector to sum signals together, and a laser cavity to perform a nonlinear operation. Its speed outpaces accelerated-time neuromorphic electronics, and it represents a viable direction towards scalable networking approaches.

  6. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    OpenAIRE

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. ...

  7. Interference-aware power control for multi-radio multi-channel wireless mesh networks

    CSIR Research Space (South Africa)

    Olwal, TO

    2009-09-01

    Full Text Available are well known in [9], [6]. The operation of multi-radio multi-channel (MRMC) WMNs generally requires sustainable energy supply. Substantial deployments of WMNs have recently been witnessed in rural and remote communities [4]. In such applications...]. Power resources are dynamically adjusted by each NIC using intra and inter-subsystem (channel) states. Due to the decentralized nature, each MP assumes imperfect knowledge about the global network. Further we assume that there exists...

  8. The software for the USB-based multi-channel analyzer system

    International Nuclear Information System (INIS)

    Zhou Tong; Wei Yixiang

    2002-01-01

    A new type of multi-channel analyzer system is introduced, which takes advantage of Universal Serial Bus to communicate with computer and gets the merit of fast speed, universality and Plug and Play. The authors discussed the framework of the system, primary functions, display of spectrum date and the way of communication with hardware. The environment of the program is Visual Basic 6.0

  9. Study and realization of a multi channel analyzer for a per operator probe

    International Nuclear Information System (INIS)

    Yahyaoui, Sarra; Brini, Borhen

    2006-01-01

    The goal of this project is to study and produce a Multi Channel Analyzer (MCA) prototype based on a microcontroller PIC 16F877. This prototype comprises an amplification and a peak detection parts. The microcontroller provide the analog to numeric conversion and ensures the communication with PC. This MCA will be connected to a per operator probe containing a semiconductor detector CdTe. (author). 7 refs

  10. Research on development of multi-channel analyzer used for monitoring and warning radiation equipment

    International Nuclear Information System (INIS)

    Nguyen Van Sy; Dang Quang Thieu; Nguyen Thi Bao My

    2015-01-01

    The subject assigned to this paper presents research on development of multi-channel analyzer used for monitoring and warning environmental radiation equipment under the project KC.05.16/11-15 Research on manufacturing equipment monitoring and warning radiation. In this thematic we have two subjects that need to be resolved such as: i) Designing spectroscopy amplifier block (AMP) duty pulse signals obtained about few hundred millivolts output from scintillation detector preamplifier, amplified as a few volts and the standard Gaussian pulses shaped to connect to the analog-to-digital converter. The spectroscopy amplifier block can change the gain by digital control to respond to the problem of automatic spectrum stability for multi-channel analyzer systems. ii) Designing analog-to-digital converter block (ADC) in accordance with the actual conditions, such as high stability, fast conversion time, high throughput, and it consumes low energy. Selecting suitable microprocessor for fast connection ability, to operate reliably paired with the analog-to-digital converter into a multi-channel analyzer (MCA) serving analysis. (author)

  11. Development of refined MCNPX-PARET multi-channel model for transient analysis in research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kalcheva, S.; Koonen, E. [SCK-CEN, BR2 Reactor Dept., Boeretang 200, 2400 Mol (Belgium); Olson, A. P. [RERTR Program, Nuclear Engineering Div., Argonne National Laboratory, Cass Avenue, Argonne, IL 60439 (United States)

    2012-07-01

    Reactivity insertion transients are often analyzed (RELAP, PARET) using a two-channel model, representing the hot assembly with specified power distribution and an average assembly representing the remainder of the core. For the analysis of protected by the reactor safety system transients and zero reactivity feedback coefficients this approximation proves to give adequate results. However, a more refined multi-channel model representing the various assemblies, coupled through the reactivity feedback effects to the whole reactor core is needed for the analysis of unprotected transients with excluded over power and period trips. In the present paper a detailed multi-channel PARET model has been developed which describes the reactor core in different clusters representing typical BR2 fuel assemblies. The distribution of power and reactivity feedback in each cluster of the reactor core is obtained from a best-estimate MCNPX calculation using the whole core geometry model of the BR2 reactor. The sensitivity of the reactor response to power, temperature and energy distributions is studied for protected and unprotected reactivity insertion transients, with zero and non-zero reactivity feedback coefficients. The detailed multi-channel model is compared vs. simplified fewer-channel models. The sensitivities of transient characteristics derived from the different models are tested on a few reactivity insertion transients with reactivity feedback from coolant temperature and density change. (authors)

  12. Simulation study on vertically distributed multi-channel tangential interferometry for KSTAR

    International Nuclear Information System (INIS)

    Nam, Y U; Juhn, J W

    2012-01-01

    Interferometry is powerful and reliable diagnostics which measures line-integrated electron density. Since this technique only measures an averaged value over whole probing line, a multi-channel scheme is used for an analysis for spatial distribution and variation of electron density. Typical setups of the multi-channel measurement are schemes of radially distributed vertical lines, vertically distributed horizontal lines and horizontally distributed tangential lines. In Korea Superconducting Tokamak Advanced Research, a vertically distributed multi-channel tangential interferometry is planned instead of above typical schemes due to limitation of complex in-vessel geometry and narrow diagnostics port through cryostat. Total 5-channels will be vertically placed as symmetric with the mid-plain. One of the characteristic features of the vertically distributed channels is that each channel is viewing different poloidal angle, while the horizontally distributed channels are viewing different toroidal angle. This scheme also can be used on an investigation of the up-down asymmetry and the vertical oscillation of plasma. Simulation has been performed and the result will be discussed to verify the possibility and the estimated effectiveness of the scheme on this paper.

  13. Content-Based Multi-Channel Network Coding Algorithm in the Millimeter-Wave Sensor Network

    Directory of Open Access Journals (Sweden)

    Kai Lin

    2016-07-01

    Full Text Available With the development of wireless technology, the widespread use of 5G is already an irreversible trend, and millimeter-wave sensor networks are becoming more and more common. However, due to the high degree of complexity and bandwidth bottlenecks, the millimeter-wave sensor network still faces numerous problems. In this paper, we propose a novel content-based multi-channel network coding algorithm, which uses the functions of data fusion, multi-channel and network coding to improve the data transmission; the algorithm is referred to as content-based multi-channel network coding (CMNC. The CMNC algorithm provides a fusion-driven model based on the Dempster-Shafer (D-S evidence theory to classify the sensor nodes into different classes according to the data content. By using the result of the classification, the CMNC algorithm also provides the channel assignment strategy and uses network coding to further improve the quality of data transmission in the millimeter-wave sensor network. Extensive simulations are carried out and compared to other methods. Our simulation results show that the proposed CMNC algorithm can effectively improve the quality of data transmission and has better performance than the compared methods.

  14. An interactive visualization tool for multi-channel confocal microscopy data in neurobiology research

    KAUST Repository

    Yong Wan,

    2009-11-01

    Confocal microscopy is widely used in neurobiology for studying the three-dimensional structure of the nervous system. Confocal image data are often multi-channel, with each channel resulting from a different fluorescent dye or fluorescent protein; one channel may have dense data, while another has sparse; and there are often structures at several spatial scales: subneuronal domains, neurons, and large groups of neurons (brain regions). Even qualitative analysis can therefore require visualization using techniques and parameters fine-tuned to a particular dataset. Despite the plethora of volume rendering techniques that have been available for many years, the techniques standardly used in neurobiological research are somewhat rudimentary, such as looking at image slices or maximal intensity projections. Thus there is a real demand from neurobiologists, and biologists in general, for a flexible visualization tool that allows interactive visualization of multi-channel confocal data, with rapid fine-tuning of parameters to reveal the three-dimensional relationships of structures of interest. Together with neurobiologists, we have designed such a tool, choosing visualization methods to suit the characteristics of confocal data and a typical biologist\\'s workflow. We use interactive volume rendering with intuitive settings for multidimensional transfer functions, multiple render modes and multi-views for multi-channel volume data, and embedding of polygon data into volume data for rendering and editing. As an example, we apply this tool to visualize confocal microscopy datasets of the developing zebrafish visual system.

  15. Energy reduction using multi-channels optical wireless communication based OFDM

    Science.gov (United States)

    Darwesh, Laialy; Arnon, Shlomi

    2017-10-01

    In recent years, an increasing number of data center networks (DCNs) have been built to provide various cloud applications. Major challenges in the design of next generation DC networks include reduction of the energy consumption, high flexibility and scalability, high data rates, minimum latency and high cyber security. Use of optical wireless communication (OWC) to augment the DC network could help to confront some of these challenges. In this paper we present an OWC multi channels communication method that could lead to significant energy reduction of the communication equipment. The method is to convert a high speed serial data stream to many slower and parallel streams and vies versa at the receiver. We implement this concept of multi channels using optical orthogonal frequency division multiplexing (O-OFDM) method. In our scheme, we use asymmetrically clipped optical OFDM (ACO-OFDM). Our results show that the realization of multi channels OFDM (ACO-OFDM) methods reduces the total energy consumption exponentially, as the number of channels transmitted through them rises.

  16. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    Science.gov (United States)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  17. Advanced Modular, Multi-Channel, High Speed Fiber Optic Sensing System for Acoustic Emissions Monitoring, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Intelligent Fiber Optic Systems Corporation (IFOS) proposes to prove the feasibility of innovations based on ultra-light-weight, ultra-high-speed, multi-channel,...

  18. Differences between otolith- and semicircular canal-activated neural circuitry in the vestibular system.

    Science.gov (United States)

    Uchino, Yoshio; Kushiro, Keisuke

    2011-12-01

    In the last two decades, we have focused on establishing a reliable technique for focal stimulation of vestibular receptors to evaluate neural connectivity. Here, we summarize the vestibular-related neuronal circuits for the vestibulo-ocular reflex, vestibulocollic reflex, and vestibulospinal reflex arcs. The focal stimulating technique also uncovered some hidden neural mechanisms. In the otolith system, we identified two hidden neural mechanisms that enhance otolith receptor sensitivity. The first is commissural inhibition, which boosts sensitivity by incorporating inputs from bilateral otolith receptors, the existence of which was in contradiction to the classical understanding of the otolith system but was observed in the utricular system. The second mechanism, cross-striolar inhibition, intensifies the sensitivity of inputs from both sides of receptive cells across the striola in a single otolith sensor. This was an entirely novel finding and is typically observed in the saccular system. We discuss the possible functional meaning of commissural and cross-striolar inhibition. Finally, our focal stimulating technique was applied to elucidate the different constructions of axonal projections from each vestibular receptor to the spinal cord. We also discuss the possible function of the unique neural connectivity observed in each vestibular receptor system. Copyright © 2011 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  19. Membrane properties of chick semicircular canal hair cells in situ during embryonic development.

    Science.gov (United States)

    Masetto, S; Perin, P; Malusà, A; Zucca, G; Valli, P

    2000-05-01

    The electrophysiological properties of developing vestibular hair cells have been investigated in a chick crista slice preparation, from embryonic day 10 (E10) to E21 (when hatching would occur). Patch-clamp whole-cell experiments showed that different types of ion channels are sequentially expressed during development. An inward Ca(2+) current and a slow outward rectifying K(+) current (I(K(V))) are acquired first, at or before E10, followed by a rapid transient K(+) current (I(K(A))) at E12, and by a small Ca-dependent K(+) current (I(KCa)) at E14. Hair cell maturation then proceeds with the expression of hyperpolarization-activated currents: a slow I(h) appears first, around E16, followed by the fast inward rectifier I(K1) around E19. From the time of its first appearance, I(K(A)) is preferentially expressed in peripheral (zone 1) hair cells, whereas inward rectifying currents are preferentially expressed in intermediate (zone 2) and central (zone 3) hair cells. Each conductance conferred distinctive properties on hair cell voltage response. Starting from E15, some hair cells, preferentially located at the intermediate region, showed the amphora shape typical of type I hair cells. From E17 (a time when the afferent calyx is completed) these cells expressed I(K, L), the signature current of mature type I hair cells. Close to hatching, hair cell complements and regional organization of ion currents appeared similar to those reported for the mature avian crista. By the progressive acquisition of different types of inward and outward rectifying currents, hair cell repolarization after both positive- and negative-current injections is greatly strengthened and speeded up.

  20. The impact of the multi-channel retail mix on online store choice: Does online experience matter?

    OpenAIRE

    Melis, Kristina; Campo, Katia; Breugelmans, Els; Lamey, Lien

    2015-01-01

    More and more grocery retailers are becoming multi-channel retailers, as they are opening an online alternative next to their traditional offline supermarkets. While the number of multi-channel grocery shoppers is also expanding at a fast growth rate, there are still large differences in online shopping frequency, and as a result, in the levels of experience with buying in the online grocery channel. This study wants to (i) identify the underlying drivers of online store choice and (ii) explo...

  1. CANAL code

    International Nuclear Information System (INIS)

    Gara, P.; Martin, E.

    1983-01-01

    The CANAL code presented here optimizes a realistic iron free extraction channel which has to provide a given transversal magnetic field law in the median plane: the current bars may be curved, have finite lengths and cooling ducts and move in a restricted transversal area; terminal connectors may be added, images of the bars in pole pieces may be included. A special option optimizes a real set of circular coils [fr

  2. A high-throughput, multi-channel photon-counting detector with picosecond timing

    Science.gov (United States)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  3. A high-throughput, multi-channel photon-counting detector with picosecond timing

    International Nuclear Information System (INIS)

    Lapington, J.S.; Fraser, G.W.; Miller, G.M.; Ashton, T.J.R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  4. Analysis of flow distribution instability in parallel thin rectangular multi-channel system

    Energy Technology Data Exchange (ETDEWEB)

    Xia, G.L. [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China); Su, G.H., E-mail: ghsu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an City 710049 (China); Peng, M.J. [Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University, Harbin City 150001 (China)

    2016-08-15

    Highlights: • Flow distribution instability in parallel thin rectangular multi-channel system is studied using RELAP5 codes. • Flow excursion may bring parallel heating channel into the density wave oscillations region. • Flow distribution instability is more likely to happen at low power/flow ratio conditions. • The increase of channel number will not affect the flow distribution instability boundary. • Asymmetry inlet throttling and heating will make system more unstable. - Abstract: The flow distribution instability in parallel thin rectangular multi-channel system has been researched in the present study. The research model of parallel channel system is established by using RELAP5/MOD3.4 codes. The transient process of flow distribution instability is studied at imposed inlet mass flow rate and imposed pressure drop conditions. The influence of heating power, mass flow rate, system pressure and channel number on flow distribution instability are analyzed. Furthermore, the flow distribution instability of parallel two-channel system under asymmetric inlet throttling and heating power is studied. The results show that, if multi-channel system operates at the negative slope region of channel ΔP–G curve, small disturbance in pressure drop will lead to flow redistribution between parallel channels. Flow excursion may bring the operating point of heating channel into the density-wave oscillations region, this will result in out-phase or in-phase flow oscillations. Flow distribution instability is more likely to happen at low power/flow ratio conditions, the stability of parallel channel system increases with system pressure, the channel number has a little effect on system stability, but the asymmetry inlet throttling or heating power will make the system more unstable.

  5. Multi-channel electrical impedance tomography for regional tissue hydration monitoring.

    Science.gov (United States)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-06-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical

  6. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin; Zhang Qi; Zheng Futang

    2000-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images are presented. The software for object separating, mass calculating, 3D positioning, speed determining and cavity reconstruction are described

  7. Network based multi-channel digital flash X-ray imaging system

    International Nuclear Information System (INIS)

    Wang Jingjin; Yuan Jie; Liu Yaqiang; Lin Yong; Song Zheng; Liu Keyin

    2003-01-01

    A network based multi-channel digital flash X-ray imaging system has been developed. It can be used to acquire and digitize orthogonal flash X-ray images in multi-interval, and to distribute the images on the network. There is no need of films and chemical process, no anxiety of waiting and no trouble of film archiving. This system is useful for testing ballistics, jet, explode, armour-piercing and fast running machines. The system composing and acquired images of terminal ballistics are presented. The software for object separating, profile calculating and 3D cavity reconstruction are described

  8. Design of multi-channel analyzer's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Yang Tao; Wei Yixiang

    2007-01-01

    A new Multi-Channel Analyzer's Monitoring system based on ARM9 Embedded system is introduced in this paper. Some solutions to problem are also discussed during the procedure of design, installation and debugging on Linux system. The Monitoring system is developed by using MiniGUI and Linux software system API, with the functions of collecting, displaying and I/O data controlling 1024 channels datum. They are all realized in real time, with the merits of low cost, small size and portability. All these lay the foundation of developing homemade Digital and Portable nuclear spectrometers. (authors)

  9. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic....... The dereverberation performance of the algorithm is evaluated using computer simulations with realistic hearing aid microphone signals including head-related effects. The algorithm is shown to work well with signals reverberated both by synthetic and by measured room impulse responses, achieving improvements...

  10. Multi-channel time-division integrator in HL-2A

    International Nuclear Information System (INIS)

    Yan Ji

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration (magnetic confinement controlled nuclear fusion device). To find out the details of on-going fusion reaction at different times is of important significance in achieving controlled nuclear fusion. We developed a new type multi-channel time-division integrator for HL-2A. It has functions of automatic cutting off negative pulse of the input signals, optional integrating time division spacing 0.2-1 ms, TTL starting trigger signal, automatic regularly work 20 s, and integrating 10 channel at the same time. (authors)

  11. Independent multi-channel analyzer with the color display and microcomputer in the CAMAC standard

    International Nuclear Information System (INIS)

    Gyunter, Z.; Elizarov, O.I.; Zhukov, G.P.; Mikhaehlis, B.; Shul'tts, K.Kh.

    1983-01-01

    An independent multi-channel time-of-flight analyzer developed for a spectrometer of polarised neutrons and used in experiments with the IBR-2 pulse reactor is described. Different cyclic modes of measuring are realized in the analyzer, 4 kwords of analyzer momory being assigned for each mode. The spectra are displayed on a colour screen during measurements. Simultaneous displaying of up to 8 spectra is possible. A microcomputer transfers the spectra from the buffer analyzer memory to the microcomputer memory. The accumulated information is transferred to the PDP-11/70 central computer

  12. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  13. A multi-channel photometric detector for multi-component analysis in flow injection analysis.

    Science.gov (United States)

    Tan, A; Huang, J; Geng, L; Xu, J; Zhao, X

    1994-01-01

    The detector, a multi-channel photometric detector, described in this paper was developed using multi-wavelength LEDs (light emitting diode) and phototransistors for absorbance measurement controlled by an Intel 8031 8-bit single chip microcomputer. Up to four flow cells can be attached to the detector. The LEDs and phototransistors are both inexpensive, and reliable. The results given by the detector for simultaneous determination of trace amounts of cobalt and cadmium in zinc sulphate electrolyte are reported. Because of the newly developed detector, this approach employs much less hardware apparatus than by employing conventional photometric detectors.

  14. Characteristics of crosstalk in the reproduced output of a newly developed multi-channel MR head

    International Nuclear Information System (INIS)

    Machida, K.; Hayashi, N.; Yoneda, Y.; Numazawa, J.; Kohro, M.; Tanabe, T.

    2001-01-01

    We prepared the multi-channel magnetoresistive head with a simple structural design and it has the advantages of high-density recording and ultra-high transfer rate. Characteristics of crosstalk in the reproduced output of our head have been estimated by a micromagnetic calculation using the Landau-Lifshitz-Gilbert (LLG) equation, while the specimen head was fabricated and evaluated. As a result, by applying a magnetic field of 40 Oe only between adjacent channels, the crosstalk was much decreased without reducing the reproduced output

  15. Pre-experiment testing of the Multi Channel Systems 16-channel preamplifier CPA16

    International Nuclear Information System (INIS)

    Patin, J B; Stoyer, M A; Moody, K J; Friensehner, A V

    2003-01-01

    The 16-channel preamplifier model CPA16 from Multi Channel Systems was studied. The CPA16 preamplifier/amplifier module is a candidate to be used as the preamplifiers and amplifiers for the focal plane detectors of the Mass Analyzer of Super Heavy Atoms (MASHA). The equipment used to test the CPA16, the results of testing the CPA16 with a pulser, a mixed 229 Th/ 148 Gd source and a 252 Cf source, and a summary of the results will be presented

  16. A high resolution 16 k multi-channel analyzer PC add-on card

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Paulson, Molly; Vaidya, P.P.

    2001-01-01

    This paper describes the system details of a 16 K channel resolution Multi-Channel Analyzer (MCA) developed at Electronics Division, BARC, which is used in high resolution nuclear spectroscopy systems for pulse height analysis. The high resolution data acquisition PC add-on card is architectured using a state of the art digital circuit design technology which makes use of a Field Programmable Gate Array (FPGA), and some of the most modern and advanced analog counterparts like low power, high speed and high precision comparators, Op-amps, ADCs and DACs etc. The 16 K MCA card gives an economic, compact, and low power alternative for nuclear pulse spectroscopy use. (author)

  17. Reprocessing of multi-channel seismic-reflection data collected in the Chukchi Sea

    Science.gov (United States)

    Agena, W.F.; Lee, M.W.; Hart, P.E.

    2001-01-01

    Contained on this set of two CD-ROMs are stacked and migrated multi-channel seismic-reflection data for 44 lines recorded in the Chukchi Sea, northern Alaska, by the United States Geological Survey in 1977, 1978, and 1980. All data were reprocessed by the USGS in 2000 using updated methods. The resulting final data have both increased temporal and spatial resolution thus providing improved interpretability. An added benefit of these CD-ROMs is that they are a more stable, long-term archival medium for the data.

  18. Electro-optic tunable multi-channel filter in two-dimensional ferroelectric photonic crystals

    International Nuclear Information System (INIS)

    Fu, Yulan; Zhang, Jiaxiang; Hu, Xiaoyong; Gong, Qihuang

    2010-01-01

    An electro-optic tunable multi-channel filter is presented, which is based on a two-dimensional ferroelectric photonic crystal made of barium titanate. The filtering properties of the photonic crystal filter can be tuned by an applied voltage or by adjusting the structural parameters. The channel shifts about 30 nm under excitation of an applied voltage of 54.8 V. The influences of the structural disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed

  19. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...

  20. Applying a CPLD for Refurbishment of a Multi-channel Pulse Height Analyzer

    International Nuclear Information System (INIS)

    Leetragunpichitchai, Supalerk; Thong-Aram, Decho; Ploykrachang, Kamontip

    2007-08-01

    Full text: This research applied a CPLD for construction of a 100 MHz, 2048 channel, Wilkinson type analog to digital converter (ADC) circuits for refurbishment of an original multi-channel pulse height analyzer (PHA) ADC. Introduction of the CPLD could reduce the complexity of the circuits, equipment size and also the power consumption while the operation speed was increased. The linearity test of the ADC was found to be excellent with an R2 = 0.9995 and a maximum pulse rate of 48.828 k cps could be converted in this system. Therefore the developed system was appropriate for replacing the original ADC

  1. On a multi-channel transportation loss system with controlled input and controlled service

    Directory of Open Access Journals (Sweden)

    Jewgeni Dshalalow

    1987-01-01

    Full Text Available A multi-channel loss queueing system is investigated. The input stream is a controlled point process. The service in each of m parallel channels depends on the state of the system at certain moments of time when input and service may be controlled. To obtain explicitly the limiting distribution of the main process (Zt (the number of busy channels in equilibrium, an auxiliary three dimensional process with two additional components (one of them is a semi-Markov process is treated as semi-regenerative process. An optimization problem is discussed. Simple expressions for an objective function are derived.

  2. Investigation of ultra wideband multi-channel dichroic beamsplitters from 0.3 to 52 microns

    Science.gov (United States)

    Zhang, K. Q.; Hunneman, R.; Seeley, J. S.; Hawkins, G. J.

    1990-01-01

    The development of a set of multi-channel dichroics which includes a 6 channel dichroic operating over the wavelength region from 0.3 to 52 microns is described. In order to achieve the optimum performance, the optical constraints of PbTe, Ge, and CdTe coatings in the strongly absorptive region have been determined by use of a new iterative method using normal incidence reflectance measurement of the multilayer together with initial values of energy gap and infinite refractive index for the semiconductor model. The design and manufacture of the dichroics is discussed and the final results are presented.

  3. Development of a novel fast frequency modulation scheme for the JET multi-channel reflectometer

    International Nuclear Information System (INIS)

    Deliyanakis, N.

    1999-10-01

    A novel frequency modulation scheme has been developed for the multi-channel reflectometer used to measure density profiles and density fluctuations on the JET tokamak. This reflectometer normally uses slow frequency sweeping, combined with fixed-frequency operation, to measure the group delay, as well as plasma fluctuations, at 10 different microwave frequencies. The novel scheme uses continuous frequency modulation on a time-scale much faster than that of plasma fluctuations, the main aim being to make the group delay measurement more robust against plasma fluctuations. This paper discusses the theoretical background of the scheme, gives a detailed description of the system, and presents results from plasma measurements. (author)

  4. A Portable Multi-Channel γ Spectrometer Based on Bluetooth and PDA

    International Nuclear Information System (INIS)

    Yu Xinhua; Lai Wanchang; Zhang Zhen; Chen Xiaoqiang; Wang Guangxi; Yang Qiang

    2009-01-01

    Introduces an embedded GPS portable multi-channel γ spectrometer based on PDA and blue-tooth. PDA use HP iPAQ rx5700, it has GPS and bluetooth, the position accuracy of GPS isn't more than 5 m and the transmission rate of bluetooth can reach 1 MB/s, its communication distance is up to 10 m. The instrument detection limits of U, Th and K are 1.0 ppm. 1.8 ppm. 0.17%, respectively. The result of experiment proves γ spectrometer based on bluetooth and PDA has low-power, strong anti-interference capability and good portable capability. (authors)

  5. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  6. Development of a USB-based multi-channel time division scaler for HL-2A

    International Nuclear Information System (INIS)

    Liang Ping

    2008-01-01

    HL-2A is China's first Tokamak device with divertor configuration. Mastering the process and plasma parameter changes with time are of great significance to achieve controlled nuclear fusion. In the recent upgrading of HL-2A, for which a higher and faster electronic equipment was required, we developed a new type USB multi-channel time division scaler for HL-2A including functions: USB interface, PC graphical user interface, simultaneously calibrating more than five channel signals, optional time division spacing 2-50 ms, count rate up to over 2 MHz, accessing all the information 20 s after a activated signal, and processing data and displaying off-line. (authors)

  7. Study on the dissociative recombination of HeH+ by multi-channel quantum defect theory

    Directory of Open Access Journals (Sweden)

    Takagi Hidekazu

    2015-01-01

    Full Text Available The dissociative recombination of HeH+ is studied using multi-channel quantum defect theory. We investigated how the partial waves of incident electrons affect the DR cross section. The DR cross section depends on the position of the center of partial wave expansion for the adiabatic S-matrix of electron scattering. When the Rydberg states correlate with the Rydberg states of the hydrogen atom at large internuclear distances, the center should be on the hydrogen atom for a better convergence of the expansion.

  8. Rayleigh waves ellipticity and mode mis-identification in multi-channel analysis of surface waves

    DEFF Research Database (Denmark)

    Boaga, Jacopo; Cassiani, Giorgio; Strobbia, Claudio

    dispersion curve which is then inverted. Typically, single component vertical and multi channel receivers are used. In most cases the inversion of the dispersion properties is carried out assuming that the experimental dispersion curve corresponds to a single mode, mostly the fundamental Rayleigh mode...... to each other reaching similar Rayleigh velocity. It is known ‘osculation’ happens generally in presence of strong velocity contrasts, typically with a fast bedrock underlying loose sediments. The practical limitations of the acquired data affect the spectral and modal resolution, making it often...

  9. On-line gas mixing and multi-channel distribution system

    International Nuclear Information System (INIS)

    Kalmani, S.D.; Mondal, N.K.; Satyanarayana, B.; Verma, P.; Joshi, Avinash

    2009-01-01

    In this presentation, we describe a mass-flow controller based on-line gas mixing unit with the multi-channel distribution system. We highlight different aspects such as requirement, design, calibration, control and operation of this system. This unit has the capability to mix up to four different input gases and distribute over 16 output channels. Output in individual channels is controlled accurately by using capillary-based system. At present, we are using this gas mixing unit for prototype of iron calorimeter (ICAL) detector of India-based Neutrino Observatory (INO).

  10. [Necessity of repeated roll test in horizontal semicircular canalithasis positioned diagnosis].

    Science.gov (United States)

    Lu, H H; Zhao, Y; Chen, T S; Xu, K X; Wang, W; Liu, Q; Wen, C; Li, S S; Li, X J; Han, X; Lin, P

    2016-04-07

    To investigate the influence of repeated roll test in horizontal semicircular canalithasis(HSC-Can) positioned diagnosis, so as to investigate the cecessity of repeated roll test. The patients with a chief complaint of positional vertigo accepted two consecutive cycles roll test, the evoked nystagmus characteristics of each cycle recorded by video-nystagmuograph(VNG), whose direction, intensity, time and other parameters characteristics were analyzed in 51 HSC-Can. Horizontal nystagmus in the same direction with turning were induced in HSC-Can roll test. In 51 HSC-Can, roll test cycle 1 and cycle 2 induced nystagmus same strength side in 26 cases(51.0%), of which 19 cases with stronger nystagmus intensity in cycle 2, another 7 cases were weaker; the opposite strength side of the two loops induced nystagmus, and cycle 1 evoked nystagmus intensity were weaker than cycle 2, based on cycle 2 results determined HSC-Can affected side in 25 cases (49.0%). Lesion and normal side in cycle 1 induced nystagmus duration (x±s, the same below) were (13.4±11.5)s and (14.1±9.9)s, respectively intensity (18.1±22.4)°/s and (13.0±12.0)°/s; as in cycle 2 induced nystagmus duration was (20.7±10.2)s and (18.0±12.0)s, strength respectively(40.4±28.0)°/s and (15.6 ±11.2)°/s. Cycle 2 ipsilateral rotor position evoked nystagmus showed longer duration and stronger intensity than cycle 1. Between two cycle induced ipsilateral nystagmus duration, intensity differences were statistically significant (t values were -4.233 and -5.154, P=0.000). 51 HSC-Can patients, 44 patients selected repositioning maneuver, after 1-2 times of maneuver, 41 cases (93.2%) showed complete resolution of symptoms, all cases's symptoms were improved; other 7 patients selected medication only. The proposed suspicious HSC-Can patients should receive at least two cycles roll test, and mainly in the second cycle could determine the location of the responsible semicircular canals.

  11. An Efficient VLSI Architecture for Multi-Channel Spike Sorting Using a Generalized Hebbian Algorithm

    Directory of Open Access Journals (Sweden)

    Ying-Lun Chen

    2015-08-01

    Full Text Available A novel VLSI architecture for multi-channel online spike sorting is presented in this paper. In the architecture, the spike detection is based on nonlinear energy operator (NEO, and the feature extraction is carried out by the generalized Hebbian algorithm (GHA. To lower the power consumption and area costs of the circuits, all of the channels share the same core for spike detection and feature extraction operations. Each channel has dedicated buffers for storing the detected spikes and the principal components of that channel. The proposed circuit also contains a clock gating system supplying the clock to only the buffers of channels currently using the computation core to further reduce the power consumption. The architecture has been implemented by an application-specific integrated circuit (ASIC with 90-nm technology. Comparisons to the existing works show that the proposed architecture has lower power consumption and hardware area costs for real-time multi-channel spike detection and feature extraction.

  12. Scene text detection by leveraging multi-channel information and local context

    Science.gov (United States)

    Wang, Runmin; Qian, Shengyou; Yang, Jianfeng; Gao, Changxin

    2018-03-01

    As an important information carrier, texts play significant roles in many applications. However, text detection in unconstrained scenes is a challenging problem due to cluttered backgrounds, various appearances, uneven illumination, etc.. In this paper, an approach based on multi-channel information and local context is proposed to detect texts in natural scenes. According to character candidate detection plays a vital role in text detection system, Maximally Stable Extremal Regions(MSERs) and Graph-cut based method are integrated to obtain the character candidates by leveraging the multi-channel image information. A cascaded false positive elimination mechanism are constructed from the perspective of the character and the text line respectively. Since the local context information is very valuable for us, these information is utilized to retrieve the missing characters for boosting the text detection performance. Experimental results on two benchmark datasets, i.e., the ICDAR 2011 dataset and the ICDAR 2013 dataset, demonstrate that the proposed method have achieved the state-of-the-art performance.

  13. Salt intrusion in multi-channel estuaries: a case study in the Mekong Delta, Vietnam

    Directory of Open Access Journals (Sweden)

    A. D. Nguyen

    2006-01-01

    Full Text Available There is a well-tested theory for the computation of salt intrusion in alluvial estuaries that is fully analytical and predictive. The theory uses analytical equations to predict the mixing behaviour of the estuary based on measurable quantities, such as channel topography, river discharge and tidal characteristics. It applies to single-channel topographies and estuaries that demonstrate moderate tidal damping. The Mekong delta is a multi-channel estuary where the tide is damped due to a relatively strong river discharge (in the order of 2000 m3/s, even during the dry season. As a result the Mekong is a strongly riverine estuary. This paper aims to test if the theory can be applied to such a riverine multi-channel estuary, and to see if possible adjustments or generalisations need to be made. The paper presents salt intrusion measurements that were done by moving boat in 2005, to which the salt intrusion model was calibrated. The theory has been expanded to cater for tidal damping. Subsequently the model has been validated with observations made at fixed locations over the years 1998 and 1999. Finally it has been tested whether the Mekong calibration fits the overall predictive equations derived in other estuaries. The test has been successful and led to a slight adjustment of the predictive equation to cater for estuaries that experience a sloping bottom.

  14. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  15. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2012-01-01

    Full Text Available The human hand has multiple degrees of freedom (DOF for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  16. Hand motion classification using a multi-channel surface electromyography sensor.

    Science.gov (United States)

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  17. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    International Nuclear Information System (INIS)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-01-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s −1 , the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay. (paper)

  18. Wireless acquisition of multi-channel seismic data using the Seismobile system

    Science.gov (United States)

    Isakow, Zbigniew

    2017-11-01

    This paper describes the wireless acquisition of multi-channel seismic data using a specialized mobile system, Seismobile, designed for subsoil diagnostics for transportation routes. The paper presents examples of multi-channel seismic records obtained during system tests in a configuration with 96 channels (4 landstreamers of 24-channel) and various seismic sources. Seismic waves were generated at the same point using different sources: a 5-kg hammer, a Gisco's source with a 90-kg pile-driver, and two other the pile-drivers of 45 and 70 kg. Particular attention is paid to the synchronization of source timing, the measurement of geometry by autonomous GPS systems, and the repeatability of triggering measurements constrained by an accelerometer identifying the seismic waveform. The tests were designed to the registration, reliability, and range of the wireless transmission of survey signals. The effectiveness of the automatic numbering of measuring modules was tested as the system components were arranged and fixed to the streamers. After measurements were completed, the accuracy and speed of data downloading from the internal memory (SDHC 32GB WiFi) was determined. Additionally, the functionality of automatic battery recharging, the maximum survey duration, and the reliability of battery discharge signalling were assessed.

  19. Metasurface for multi-channel terahertz beam splitters and polarization rotators

    Science.gov (United States)

    Zang, XiaoFei; Gong, HanHong; Li, Zhen; Xie, JingYa; Cheng, QingQing; Chen, Lin; Shkurinov, Alexander P.; Zhu, YiMing; Zhuang, SongLin

    2018-04-01

    Terahertz beam splitters and polarization rotators are two typical devices with wide applications ranging from terahertz communication to system integration. However, they are faced with severe challenges in manipulating THz waves in multiple channels, which is desirable for system integration and device miniaturization. Here, we propose a method to design ultra-thin multi-channel THz beam splitters and polarization rotators simultaneously. The reflected beams are divided into four beams with nearly the same density under illumination of linear-polarized THz waves, while the polarization of reflected beams in each channel is modulated with a rotation angle or invariable with respect to the incident THz waves, leading to the multi-channel polarization rotator (multiple polarization rotation in the reflective channels) and beam splitter, respectively. Reflective metasurfaces, created by patterning metal-rods with different orientations on a polyimide film, were fabricated and measured to demonstrate these characteristics. The proposed approach provides an efficient way of controlling polarization of THz waves in various channels, which significantly simplifies THz functional devices and the experimental system.

  20. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  1. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    Science.gov (United States)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  2. A wireless multi-channel bioimpedance measurement system for personalized healthcare and lifestyle.

    Science.gov (United States)

    Ramos, Javier; Ausín, José Luis; Lorido, Antonio Manuel; Redondo, Francisco; Duque-Carrillo, Juan Francisco

    2013-01-01

    Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.

  3. Analysis and compensation of synchronous measurement error for multi-channel laser interferometer

    Science.gov (United States)

    Du, Shengwu; Hu, Jinchun; Zhu, Yu; Hu, Chuxiong

    2017-05-01

    Dual-frequency laser interferometer has been widely used in precision motion system as a displacement sensor, to achieve nanoscale positioning or synchronization accuracy. In a multi-channel laser interferometer synchronous measurement system, signal delays are different in the different channels, which will cause asynchronous measurement, and then lead to measurement error, synchronous measurement error (SME). Based on signal delay analysis of the measurement system, this paper presents a multi-channel SME framework for synchronous measurement, and establishes the model between SME and motion velocity. Further, a real-time compensation method for SME is proposed. This method has been verified in a self-developed laser interferometer signal processing board (SPB). The experiment result showed that, using this compensation method, at a motion velocity 0.89 m s-1, the max SME between two measuring channels in the SPB is 1.1 nm. This method is more easily implemented and applied to engineering than the method of directly testing smaller signal delay.

  4. Application of a multi-channel system for continuous monitoring and an early warning system.

    Science.gov (United States)

    Lee, J H; Song, C H; Kim, B C; Gu, M B

    2006-01-01

    A multi-channel continuous toxicity monitoring system developed in our laboratory, based on two-stage mini-bioreactors, was successfully implemented in the form of computer-based data acquisition. The multi-channel system consists of a series of a two-stage minibioreactor systems connected by a fiber optic probe to a luminometer, and uses genetically engineered bioluminescent bacteria for the detection of the potential toxicity from the soluble chemicals. This system can be stably and continuously operated due to the separation of the culture reactor from the test reactor and accomplish easy and long-term monitoring without system shut down by abrupt inflows of severe polluting chemicals. Four different recombinant bioluminescent bacteria were used in different channels so that the modes of the samples toxicities can be reasonably identified and evaluated based upon the response signature of each channel. The bioluminescent signatures were delivered from four channels by switching one at once, while the data is automatically logged to an IBM compatible computer. We also achieved the enhancement of the system through the manipulation of the dilution rate and the use of thermo-lux fusion strains. Finally, this system is now being implemented to a drinking water reservoir and river for remote sensing as an early warning system.

  5. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  6. Canal rays

    International Nuclear Information System (INIS)

    Goldstein, Eugen

    2010-01-01

    For more than fifty years the German physicist Eugen Goldstein was engaged in an obscure fringe field of physics, on which he has impressed like no other: Electrical gas discharges. Goldstein describes in this book his discovery of canal rays, which has given important impulses for modern atomic physics. For his research Goldstein received the Prix Hebert of the Parisienne Academie des sciences, the Hughes medal, and was repeatedly proposed for the Nobel prize. In Germany for the Jewish scientist the acknowledgement remained far-reachingly refused until after the war.

  7. The designing principle and implementation of multi-channel intelligence isotope thickness gauge based on multifunction card PCI-1710

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Guo Maotian; He Jintian

    2006-01-01

    The designing principle, the constitution of system and the implementation of multi-channel intelligence isotope thickness gauge are introduced in the paper in detail, which are based on multifunction card PCI-1710. The paper also discusses the primaryprinciple of isotope thickness gauge, correct factor in measurement and complication of calibration. In the following, the whole frame of multi-channel intelligence isotope thickness gauge is given. The functions, the characteristics and the usage of multifunction card PCI-1710 are described. Furthermore, the developing process and the function modules of software are presented. Finally, the real prototype of multi-channel intelligence isotope thickness gauge is introduced, using 241 Am as a radioactive element. (authors)

  8. Robust, highly customizable, and economical multi-channel electrode for chronic multi-unit recording in behaving animals.

    Science.gov (United States)

    Tateyama, Yukina; Oyama, Kei; Shiraishi, Masaru; Iijima, Toshio; Tsutsui, Ken-Ichiro

    2017-12-01

    Multi-unit recording has been one of the most widely used techniques to investigate the correlation between multiple neuronal activities and behavior. However, a common problem of currently used multi-channel electrodes is their physical weakness. In this study, we developed a novel multi-channel electrode with sufficient physical strength to penetrate a thickened dura mater. This electrode consists of low-cost materials and is easily fabricated, and it enables recording without removing dura mater, thereby reducing the risk of inflammation, infection, or brain herniation. The low-cost multi-channel electrode developed in this study would be a useful tool for chronic recording in behaving animals. Copyright © 2017. Published by Elsevier B.V.

  9. Multi-channel electrical impedance tomography for regional tissue hydration monitoring

    International Nuclear Information System (INIS)

    Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M

    2014-01-01

    Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ∼35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in

  10. Compact and cost-effective multi-channel optical spectrometer for fine FBG sensing in IoT technology

    Science.gov (United States)

    Konishi, Tsuyoshi; Yamasaki, Yu

    2018-02-01

    Optical fiber sensor networks have attracted much attention in IoT technology and a fiber Bragg grating is one of key sensor devices there because of their advantages in a high affinity for optical fiber networks, compactness, immunity to electromagnetic interference and so on. Nevertheless, its sensitivity is not always satisfactory so as to be usable together with widespread cost-effective multi-channel spectrometers. In this paper, we introduce a new cost-effective approach for a portable multi-channel spectrometer with high spectral resolution and demonstrates some preliminary experimental results for fine FBG sensing.

  11. Automatic pickup of arrival time of channel wave based on multi-channel constraints

    Science.gov (United States)

    Wang, Bao-Li

    2018-03-01

    Accurately detecting the arrival time of a channel wave in a coal seam is very important for in-seam seismic data processing. The arrival time greatly affects the accuracy of the channel wave inversion and the computed tomography (CT) result. However, because the signal-to-noise ratio of in-seam seismic data is reduced by the long wavelength and strong frequency dispersion, accurately timing the arrival of channel waves is extremely difficult. For this purpose, we propose a method that automatically picks up the arrival time of channel waves based on multi-channel constraints. We first estimate the Jaccard similarity coefficient of two ray paths, then apply it as a weight coefficient for stacking the multichannel dispersion spectra. The reasonableness and effectiveness of the proposed method is verified in an actual data application. Most importantly, the method increases the degree of automation and the pickup precision of the channel-wave arrival time.

  12. Research on Intelligent Control System of DC SQUID Magnetometer Parameters for Multi-channel System

    Science.gov (United States)

    Chen, Hua; Yang, Kang; Lu, Li; Kong, Xiangyan; Wang, Hai; Wu, Jun; Wang, Yongliang

    2018-03-01

    In a multi-channel SQUID measurement system, adjusting device parameters to optimal condition for all channels is time-consuming. In this paper, an intelligent control system is presented to determine the optimal working point of devices which is automatic and more efficient comparing to the manual one. An optimal working point searching algorithm is introduced as the core component of the control system. In this algorithm, the bias voltage V_bias is step scanned to obtain the maximal value of the peak-to-peak current value I_pp of the SQUID magnetometer modulation curve. We choose this point as the optimal one. Using the above control system, more than 30 weakly damped SQUID magnetometers with area of 5 × 5 mm^2 or 10 × 10 mm^2 are adjusted and a 36-channel magnetocardiography system perfectly worked in a magnetically shielded room. The average white flux noise is 15 μΦ_0/Hz^{1/2}.

  13. Selecting participants for listening tests of multi-channel reproduced sound

    DEFF Research Database (Denmark)

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  14. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  15. Design of a novel multi channel photonic crystal fiber polarization beam splitter

    Science.gov (United States)

    Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun

    2017-10-01

    A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.

  16. A customizable multi-channel loudness compensation method based on WDRC for digital hearing aids

    Science.gov (United States)

    Hu, Jiebin; Wang, Mingjiang; Ma, Min

    2017-08-01

    Loudness compensation is the most significant signal processing algorithm in digital hearing aids at present. An algorithm of multi-channel loudness compensation for embedded system has been put forward in this paper. The number of channels is customizable in this algorithm. The algorithm can set different number and different width of channels for each patient based on frequency domain wide dynamic range compression. First, according to the requirement of patient to divide the frequency domain into multiple unequal frequency bands. And then calculate the gain of each channel according to the input-output curve of sound pressure level. Finally, the time-domain impulse response of gain is computed from Mel filter banks. It is used in conjunction with speech enhancement processing in hearing aids. Simulation results show that the algorithm can effectively enhance the loudness for different frequencies.

  17. Development of a multi-channel horn mixer array for microwave imaging plasma diagnostics

    International Nuclear Information System (INIS)

    Ito, Naoki; Kuwahara, Daisuke; Nagayama, Yoshio

    2015-01-01

    Microwave to millimeter-wave diagnostics techniques, such as interferometry, reflectometry, scattering, and radiometry, have been powerful tools for diagnosing magnetically confined plasmas. The resultant measurements have clarified several physics issues, including instability, wave phenomena, and fluctuation-induced transport. Electron cyclotron emission imaging has been an important tool in the investigation of temperature fluctuations, while reflectometry has been employed to measure plasma density profiles and their fluctuations. We have developed a horn-antenna mixer array (HMA), a 50 - 110 GHz 1D antenna array, which can be easily stacked as a 2D array. This article describes an upgrade to the horn mixer array that combines well-characterized mixers, waveguide-to-microstrip line transitions, intermediate frequency amplifiers, and internal local oscillator modules using a monolithic microwave integrated circuit technology to improve system performance. We also report on the use of a multi-channel HMA system. (author)

  18. A low delay transmission method of multi-channel video based on FPGA

    Science.gov (United States)

    Fu, Weijian; Wei, Baozhi; Li, Xiaobin; Wang, Quan; Hu, Xiaofei

    2018-03-01

    In order to guarantee the fluency of multi-channel video transmission in video monitoring scenarios, we designed a kind of video format conversion method based on FPGA and its DMA scheduling for video data, reduces the overall video transmission delay.In order to sace the time in the conversion process, the parallel ability of FPGA is used to video format conversion. In order to improve the direct memory access (DMA) writing transmission rate of PCIe bus, a DMA scheduling method based on asynchronous command buffer is proposed. The experimental results show that this paper designs a low delay transmission method based on FPGA, which increases the DMA writing transmission rate by 34% compared with the existing method, and then the video overall delay is reduced to 23.6ms.

  19. A high-throughput, multi-channel photon-counting detector with picosecond timing

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchanne...

  20. [Analysis of the Muscle Fatigue Based on Band Spectrum Entropy of Multi-channel Surface Electromyography].

    Science.gov (United States)

    Liu, Jian; Zou, Renling; Zhang, Dongheng; Xu, Xiulin; Hu, Xiufang

    2016-06-01

    Exercise-induced muscle fatigue is a phenomenon that the maximum voluntary contraction force or power output of muscle is temporarily reduced due to muscular movement.If the fatigue is not treated properly,it will bring about a severe injury to the human body.With multi-channel collection of lower limb surface electromyography signals,this article analyzes the muscle fatigue by adoption of band spectrum entropy method which combined electromyographic signal spectral analysis and nonlinear dynamics.The experimental result indicated that with the increase of muscle fatigue,muscle signal spectrum began to move to low frequency,the energy concentrated,the system complexity came down,and the band spectrum entropy which reflected the complexity was also reduced.By monitoring the entropy,we can measure the degree of muscle fatigue,and provide an indicator to judge fatigue degree for the sports training and clinical rehabilitation training.

  1. The interaction between room and musical instruments studied by multi-channel auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    in the anechoic recording. With this technique the variations in sound radiation from the musical instrument during the performance e.g. due to changes in level or movements can be reproduced with the influence of the surrounding room surfaces. Examples include a grand piano and a clarinet.......The directivity of musical instruments is very complicated and typically changes from one tone to the next. So, instead of measuring the average directivity, a multi-channel auralization method has been developed, which allows a highly accurate and realistic sounding auralization of musical...... instruments in rooms. Anechoic recordings have been made with 5 and 13 evenly distributed microphones around the musical instrument. The reproduction is made with a room acoustics simulation software using a compound source, which is in fact a number of highly directive sources, one for each of the channels...

  2. Multi-channel, passive, short-range anti-aircraft defence system

    Science.gov (United States)

    Gapiński, Daniel; Krzysztofik, Izabela; Koruba, Zbigniew

    2018-01-01

    The paper presents a novel method for tracking several air targets simultaneously. The developed concept concerns a multi-channel, passive, short-range anti-aircraft defence system based on the programmed selection of air targets and an algorithm of simultaneous synchronisation of several modified optical scanning seekers. The above system is supposed to facilitate simultaneous firing of several self-guided infrared rocket missiles at many different air targets. From the available information, it appears that, currently, there are no passive self-guided seekers that fulfil such tasks. This paper contains theoretical discussions and simulations of simultaneous detection and tracking of many air targets by mutually integrated seekers of several rocket missiles. The results of computer simulation research have been presented in a graphical form.

  3. Study of multi-channel readout ASIC and its discrete module for particle detector

    International Nuclear Information System (INIS)

    Wang Ke; Fan Lei; Zhang Shengjun; Li Xian

    2013-01-01

    Recently, kinds of particle detectors have used Application Specific Integrated Circuits (ASIC) in their electronics readout systems, it is the key part for the whole system. This project designed a multi-channel readout ASIC for general detectors. The chip has Preamplifier, Shaper and Peak Detector embedded for easy readout. For each channel, signal which is preprocessed by a low-noise preamplifier is sent to the shaper to form a quasi-Gaussian pulse and keep its peak for readout. This chip and modules of individual Preamplifier, Shaper and Peak Detector have been manufactured and tested. The discrete modules work well, and the 6-channel chip NPRE 6 is ready for test in some particle detection system. (authors)

  4. FPGA based high-performance multi-channel analyzer with local histogram memory

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.

    2004-01-01

    Modern nuclear spectroscopy systems demand for a Multi-Channel Analyzer (MCA) with higher resolution, faster speed and other advanced features. The MCA described here is targeted for such demanding applications. The MCA has an in-built local histogram memory and a memory management unit integrated in an FPGA (Field Programmable Gate Array) chip. In addition to the integrated low power digital circuitry, the system utilizes state of the art advanced analog circuits like low power, high speed and high precision comparators, op-amps, ADC and DAC. The operating resolution is selectable from 256 channels to 16384 channels for pulse height analysis. It supports high count rate applications (typically 100 KHz) without significant dead time penalty. It can have an USB bus interface with simple changes. In general, the MCA gives a high performance, compact and low power alternative for portable and battery operated systems as well as for high end laboratory instruments. (author)

  5. Estimation of black carbon content for biomass burning aerosols from multi-channel Raman lidar data

    Science.gov (United States)

    Talianu, Camelia; Marmureanu, Luminita; Nicolae, Doina

    2015-04-01

    Biomass burning due to natural processes (forest fires) or anthropical activities (agriculture, thermal power stations, domestic heating) is an important source of aerosols with a high content of carbon components (black carbon and organic carbon). Multi-channel Raman lidars provide information on the spectral dependence of the backscatter and extinction coefficients, embedding information on the black carbon content. Aerosols with a high content of black carbon have large extinction coefficients and small backscatter coefficients (strong absorption), while aerosols with high content of organic carbon have large backscatter coefficients (weak absorption). This paper presents a method based on radiative calculations to estimate the black carbon content of biomass burning aerosols from 3b+2a+1d lidar signals. Data is collected at Magurele, Romania, at the cross-road of air masses coming from Ukraine, Russia and Greece, where burning events are frequent during both cold and hot seasons. Aerosols are transported in the free troposphere, generally in the 2-4 km altitude range, and reaches the lidar location after 2-3 days. Optical data are collected between 2011-2012 by a multi-channel Raman lidar and follows the quality assurance program of EARLINET. Radiative calculations are made with libRadTran, an open source radiative model developed by ESA. Validation of the retrievals is made by comparison to a co-located C-ToF Aerosol Mass Spectrometer. Keywords: Lidar, aerosols, biomass burning, radiative model, black carbon Acknowledgment: This work has been supported by grants of the Romanian National Authority for Scientific Research, Programme for Research- Space Technology and Advanced Research - STAR, project no. 39/2012 - SIAFIM, and by Romanian Partnerships in priority areas PNII implemented with MEN-UEFISCDI support, project no. 309/2014 - MOBBE

  6. Satellite rainfall monitoring over Africa for food security, using multi-channel MSG data

    Science.gov (United States)

    Chadwick, R.; Grimes, D.; Saunders, R.; Blackmore, T.; Francis, P.

    2009-04-01

    Near real-time rainfall estimates are crucial in sub-Saharan Africa for a variety of humanitarian and agricultural purposes. However, for economic and infrastructural reasons, regularly reporting rain-gauges are sparse and precipitation radar networks extremely rare. Satellite rainfall estimates, particularly from geostationary satellites such as Meteosat Second Generation (MSG), present one method of filling this information gap, as they produce data at high temporal and spatial resolution. An algorithm has been developed to produce rainfall estimates for Africa from multi-channel MSG data. The algorithm is calibrated using precipitation radar data collected in Niamey, Niger as part of the African Monsoon Multidisciplinary Analyses (AMMA) project in 2006, and is based on an algorithm used operationally over Europe by the UK Met Office. Contingency tables are used to establish a statistical relationship between multi-channel MSG data and probability of rainfall at several different rain-rate magnitudes as sensed by the radar. Rain-rate estimates can then be produced at a variety of spatial and temporal scales, with MSG scan length (15 minutes) and pixel size (3-4km) as the lower limit. Results will be presented of a validation of this algorithm over the Sahel region of Africa. Rainfall estimates from this algorithm, processed for 2004, will be validated against gridded rain-gauge data at a 0.5 degree and 10 day timescale suitable for drought monitoring purposes. A comparison will also be made against rainfall estimates from the TAMSAT algorithm, which uses single channel IR data from MSG, and has been shown to perform well in the Sahel region.

  7. Scale-free brain quartet: artistic filtering of multi-channel brainwave music.

    Science.gov (United States)

    Wu, Dan; Li, Chaoyi; Yao, Dezhong

    2013-01-01

    To listen to the brain activities as a piece of music, we proposed the scale-free brainwave music (SFBM) technology, which translated scalp EEGs into music notes according to the power law of both EEG and music. In the present study, the methodology was extended for deriving a quartet from multi-channel EEGs with artistic beat and tonality filtering. EEG data from multiple electrodes were first translated into MIDI sequences by SFBM, respectively. Then, these sequences were processed by a beat filter which adjusted the duration of notes in terms of the characteristic frequency. And the sequences were further filtered from atonal to tonal according to a key defined by the analysis of the original music pieces. Resting EEGs with eyes closed and open of 40 subjects were utilized for music generation. The results revealed that the scale-free exponents of the music before and after filtering were different: the filtered music showed larger variety between the eyes-closed (EC) and eyes-open (EO) conditions, and the pitch scale exponents of the filtered music were closer to 1 and thus it was more approximate to the classical music. Furthermore, the tempo of the filtered music with eyes closed was significantly slower than that with eyes open. With the original materials obtained from multi-channel EEGs, and a little creative filtering following the composition process of a potential artist, the resulted brainwave quartet opened a new window to look into the brain in an audible musical way. In fact, as the artistic beat and tonal filters were derived from the brainwaves, the filtered music maintained the essential properties of the brain activities in a more musical style. It might harmonically distinguish the different states of the brain activities, and therefore it provided a method to analyze EEGs from a relaxed audio perspective.

  8. Superior canal dehiscence in a patient with three failed stapedectomy operations for otosclerosis: a case report

    Directory of Open Access Journals (Sweden)

    Sudhoff Holger H

    2011-02-01

    Full Text Available Abstract Introduction This case illustrates that superior semicircular canal dehiscence syndrome can be associated with a "pseudo"-conductive hearing loss, a symptom that overlaps with the clinical appearance of otosclerosis. Case presentation We present the case of a 48-year-old German Caucasian woman presenting with hearing loss on the left side and vertigo. She had undergone three previous stapedectomies for hearing improvement. Reformatted high-resolution computed tomographic scanning and the patient's history confirmed the diagnosis of concurrent canal dehiscence syndrome. Conclusion Failure of hearing improvement after otosclerosis surgery may indicate an alternative underlying diagnosis which should be explored by further appropriate evaluation.

  9. Root canal irrigants

    OpenAIRE

    Kandaswamy, Deivanayagam; Venkateshbabu, Nagendrababu

    2010-01-01

    Successful root canal therapy relies on the combination of proper instrumentation, irrigation, and obturation of the root canal. Of these three essential steps of root canal therapy, irrigation of the root canal is the most important determinant in the healing of the periapical tissues. The primary endodontic treatment goal must thus be to optimize root canal disinfection and to prevent reinfection. In this review of the literature, various irrigants and the interactions between irrigants are...

  10. Effect of flow rate distribution at the inlet on hydrodynamic mixing in narrow rectangular multi-channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Chen Bingde; Wang Xiaojun

    2008-01-01

    Flow and heat transfer in the narrow rectangular multi-channel is widely en- countered in the engineering application, hydrodynamic mixing in the narrow rectangular multi-channel is one of the important concerns. With the help of the Computational Fluid Dynamics code CFX, the effect of flow rate distribution of the main channel at the inlet on hydrodynamic mixing in the narrow rectangular multi-channel is numerical simulated. The results show that the flow rate distributions at the inlet have a great effect on hydrodynamics mixing in multi-channel, the flow rate in the main channel doesn't change with increasing the axial mixing section when the average flow rate at the inlet is set. Hydrodynamic mixing will arise in the mixing section when the different ratio of the flow rate distribution at the inlet is set, and hydrodynamic mixing increases with the difference of the flow rate distribution at the inlet increase. The trend of the flow rate distribution of the main channel is consistent during the whole axial mixing section, and hydrodynamic mixing in former 4 mixing section is obvious. (authors)

  11. Surface Clutter Suppression Techniques Applied to P-band Multi-Channel SAR Ice Sounder Data from East Antarctica

    DEFF Research Database (Denmark)

    Lin, Chung-Chi; Bekaert, David; Gebert, Nicolas

    ., Lausanne, developed and built the radiator-elements of the enhanced POLARIS. Several datasets were acquired in the multi-channel configuration during the Feb. 2011 campaign over East Antarctica. The POLARIS instrument will be briefly introduced, followed by an overview of the sounding campaign. Finally...

  12. A Novel Spectrally Efficient Asynchronous Multi-Channel MAC Using a Half-Duplex Transceiver for Wireless Networks

    Directory of Open Access Journals (Sweden)

    Abdullah Devendiran

    2018-01-01

    Full Text Available Multi-channel medium access control (MAC protocols maximize network performance by enabling concurrent wireless transmissions over non-interfering channels. Despite physical layer advancements, the underlying IEEE 802.11 MAC standard cannot fully exploit features and support high-performance applications. In this work, we propose the novel spectrally efficient asynchronous multi-channel MAC (SA-MMAC protocol for wireless networks using a single half-duplex transceiver. A full-duplex mode of operation on data channels reduces the signaling overhead and boosts the spectrum efficiency. A revamped contention mechanism of IEEE 802.11 addresses the multi-channel hidden terminal problem, and a jamming signal from the receiver addresses the collisions in control signals. Furthermore, the control channel is used for data transmissions to increase the bandwidth utilization but under a restricted half-duplex mode to avoid causing a bottleneck situation. The simulator is tested for correctness. The results suggest that the protocol can work well on 3, 4, or 12 concurrent channels with high node density, providing about 12.5 times more throughput than IEEE 802.11 and 18% to 95% more throughput than its multi-channel variants under saturated traffic conditions.

  13. Feasibility study of applying a multi-channel analysis model to on-line core monitoring system

    International Nuclear Information System (INIS)

    In, W. K.; Yoo, Y. J.; Hwang, D. H.; Jun, T. H.

    1998-01-01

    A feasibility study was performed to evaluate the effect of implementing a multi-channel analysis model in on-line core monitoring system. A simplified thermal-hydraulic model has been used in the on-line core monitoring system of digital PWR. The design procedure, core thermal margin and computation time were investigated in case of replacing the simplified model with the multi-channel analysis model. For the given ranges of limiting conditions for operation in Yonggwang Unit 3 Cycle 1, the minimum DNBR of the simplified thermal-hydraulic code CETOP-D was compared to that of the multi-channel analysis code MATRA. A CETOP-D tuning is additionally required to ensure the accurate and conservative DNBR calculation but the MATRA tuning is not necessary. MATRA appeared to increase the DNBR overpower margin from 2.5% to 6% over the CETOP-D margin. MATRA took approximately 1 second to compute DNBR on the HP9000 workstation system, which is longer than the DNBR computation time of CETOP-D. It is, however, fast enough to perform the on-line monitoring of DNBR. It can be therefore concluded that the application of the multi-channel analysis model MATRA in the on-line core monitoring system is feasible

  14. Analysis of multi-channel seismic reflection and magnetic data along 13 degrees N latitude across the Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, D.G.; Bhattacharya, G.C.; Ramana, M.V.; Subrahmanyam, V.; Ramprasad, T.; Krishna, K.S.; Chaubey, A.K.; Murty, G.P.S.; Srinivas, K.; Desa, M.; Reddy, S.I.; Ashalata, B.; Subrahmanyam, C.; Mital, G.S.; Drolia, R.K.; rai, S.N.; Ghosh, S.K.; Singh, R.N.; Majumdar, M.

    Analysis of the multi-channel seismic reflection, magnetic and bathymetric data collected along a transect, 1110 km long parallel to 13 degrees N lat. across the Bay of Bengal was made. The transect is from the continental shelf off Madras...

  15. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    International Nuclear Information System (INIS)

    Nasr, Amgad

    2012-01-01

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N 2 , Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  16. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nasr, Amgad

    2012-07-18

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N{sub 2}, Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  17. EFFICIENCY OF REDUNDANT QUERY EXECUTION IN MULTI-CHANNEL SERVICE SYSTEMS

    Directory of Open Access Journals (Sweden)

    V. A. Bogatyrev

    2016-03-01

    Full Text Available Subject of Research.The paper deals with analysis of the effectiveness of redundant queries based on untrusted computing in computer systems, represented by multi-channel queuing systems with a common queue. The objective of research is the possibility of increasing the efficiency of service requests while performing redundant copies of requests in different devices of a multi-channel system under conditions of calculations unreliability. The redundant service of requests requires the infallibility of its implementation at least in one of the devices.Method. We have considered estimation of the average time spent in the system with and without the use of redundant requests at the presentation of a simple queuing model of the M / M / n type to analyze the effectiveness of redundant service of requests. Presented evaluation of the average waiting time in the redundant queries is the upper one, since it ignores the possibility of reducing the average waiting time as a result of the spread of the probability of time querying at different devices. The integrated efficiency of redundant service of requests is defined based on the multiplicative index that takes into account the infallibility of calculations and the average time allowance with respect to the maximum tolerated delay of service. Evaluation of error-free computing at reserved queries is received at the requirement of faultless execution of at least one copy of the request. Main Results. We have shown that the reservation of requests gives the gain in efficiency of the system at low demand rate (load. We have defined the boundaries of expediency (efficiency for redundant service of requests. We have shown the possibility of the effectiveness increasing of the adaptive changes in the multiplicity of the reservation of requests, depending on the intensity of the flow of requests. We have found out that the choice of service discipline in information service systems is largely determined by

  18. Otolith-Canal Convergence In Vestibular Nuclei Neurons

    Science.gov (United States)

    Dickman, J. David; Si, Xiao-Hong

    2002-01-01

    The current final report covers the period from June 1, 1999 to May 31, 2002. The primary objective of the investigation was to determine how information regarding head movements and head position relative to gravity is received and processed by central vestibular nuclei neurons in the brainstem. Specialized receptors in the vestibular labyrinths of the inner ear function to detect angular and linear accelerations of the head, with receptors located in the semicircular canals transducing rotational head movements and receptors located in the otolith organs transducing changes in head position relative to gravity or linear accelerations of the head. The information from these different receptors is then transmitted to central vestibular nuclei neurons which process the input signals, then project the appropriate output information to the eye, head, and body musculature motor neurons to control compensatory reflexes. Although a number of studies have reported on the responsiveness of vestibular nuclei neurons, it has not yet been possible to determine precisely how these cells combine the information from the different angular and linear acceleration receptors into a correct neural output signal. In the present project, rotational and linear motion stimuli were separately delivered while recording responses from vestibular nuclei neurons that were characterized according to direct input from the labyrinth and eye movement sensitivity. Responses from neurons receiving convergent input from the semicircular canals and otolith organs were quantified and compared to non-convergent neurons.

  19. Optimization of multi-channel neutron focusing guides for extreme sample environments

    International Nuclear Information System (INIS)

    Di Julio, D D; Lelièvre-Berna, E; Andersen, K H; Bentley, P M; Courtois, P

    2014-01-01

    In this work, we present and discuss simulation results for the design of multichannel neutron focusing guides for extreme sample environments. A single focusing guide consists of any number of supermirror-coated curved outer channels surrounding a central channel. Furthermore, a guide is separated into two sections in order to allow for extension into a sample environment. The performance of a guide is evaluated through a Monte-Carlo ray tracing simulation which is further coupled to an optimization algorithm in order to find the best possible guide for a given situation. A number of population-based algorithms have been investigated for this purpose. These include particle-swarm optimization, artificial bee colony, and differential evolution. The performance of each algorithm and preliminary results of the design of a multi-channel neutron focusing guide using these methods are described. We found that a three-channel focusing guide offered the best performance, with a gain factor of 2.4 compared to no focusing guide, for the design scenario investigated in this work.

  20. TRANTHAC-1: transient thermal-hydraulic analysis code for HTGR core of multi-channel model

    International Nuclear Information System (INIS)

    Sato, Sadao; Miyamoto, Yoshiaki

    1980-08-01

    The computer program TRANTHAC-1 is for predicting thermal-hydraulic transient behavior in HTGR's core of pin-in-block type fuel elements, taking into consideration of the core flow distribution. The program treats a multi-channel model, each single channel representing the respective column composed of fuel elements. The fuel columns are grouped in flow control regions; each region is provided with an orifice assembly. In the region, all channels are of the same shape except one channel. Core heat is removed by downward flow of the control through the channel. In any transients, for given time-dependent power, total core flow, inlet coolant temperature and coolant pressure, the thermal response of the core can be determined. In the respective channels, the heat conduction in radial and axial direction are represented. And the temperature distribution in each channel with the components is calculated. The model and usage of the program are described. The program is written in FORTRAN-IV for computer FACOM 230-75 and it is composed of about 4,000 cards. The required core memory is about 75 kilowords. (author)

  1. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Santos, D.M.; Chau, A.; DeBusshere, D.; Dow, S.; Flasck, J.; Levi, M.; Kirsten, F.; Su, E.

    1995-12-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e. 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using one eight channel TDC comprised of a delay locked loop and eight sets of latches and encoders. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. The timing and amplitude information is multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are then transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in a 0.8μ triple metal CMOS process. The TDC sub-element has been measured to have better than 135 ps time resolution and 35 ps jitter. The DRAM has a measured cycle time of 80 MHz

  2. Stochastic geometry model for multi-channel fog radio access networks

    KAUST Repository

    Emara, Mostafa

    2017-06-29

    Cache-enabled base station (BS) densification, denoted as a fog radio access network (F-RAN), is foreseen as a key component of 5G cellular networks. F-RAN enables storing popular files at the network edge (i.e., BS caches), which empowers local communication and alleviates traffic congestions at the core/backhaul network. The hitting probability, which is the probability of successfully transmitting popular files request from the network edge, is a fundamental key performance indicator (KPI) for F-RAN. This paper develops a scheduling aware mathematical framework, based on stochastic geometry, to characterize the hitting probability of F-RAN in a multi-channel environment. To this end, we assess and compare the performance of two caching distribution schemes, namely, uniform caching and Zipf caching. The numerical results show that the commonly used single channel environment leads to pessimistic assessment for the hitting probability of F-RAN. Furthermore, the numerical results manifest the superiority of the Zipf caching scheme and quantify the hitting probability gains in terms of the number of channels and cache size.

  3. A generic EEG artifact removal algorithm based on the multi-channel Wiener filter

    Science.gov (United States)

    Somers, Ben; Francart, Tom; Bertrand, Alexander

    2018-06-01

    Objective. The electroencephalogram (EEG) is an essential neuro-monitoring tool for both clinical and research purposes, but is susceptible to a wide variety of undesired artifacts. Removal of these artifacts is often done using blind source separation techniques, relying on a purely data-driven transformation, which may sometimes fail to sufficiently isolate artifacts in only one or a few components. Furthermore, some algorithms perform well for specific artifacts, but not for others. In this paper, we aim to develop a generic EEG artifact removal algorithm, which allows the user to annotate a few artifact segments in the EEG recordings to inform the algorithm. Approach. We propose an algorithm based on the multi-channel Wiener filter (MWF), in which the artifact covariance matrix is replaced by a low-rank approximation based on the generalized eigenvalue decomposition. The algorithm is validated using both hybrid and real EEG data, and is compared to other algorithms frequently used for artifact removal. Main results. The MWF-based algorithm successfully removes a wide variety of artifacts with better performance than current state-of-the-art methods. Significance. Current EEG artifact removal techniques often have limited applicability due to their specificity to one kind of artifact, their complexity, or simply because they are too ‘blind’. This paper demonstrates a fast, robust and generic algorithm for removal of EEG artifacts of various types, i.e. those that were annotated as unwanted by the user.

  4. Automatic seizure detection based on the combination of newborn multi-channel EEG and HRV information

    Science.gov (United States)

    Mesbah, Mostefa; Balakrishnan, Malarvili; Colditz, Paul B.; Boashash, Boualem

    2012-12-01

    This article proposes a new method for newborn seizure detection that uses information extracted from both multi-channel electroencephalogram (EEG) and a single channel electrocardiogram (ECG). The aim of the study is to assess whether additional information extracted from ECG can improve the performance of seizure detectors based solely on EEG. Two different approaches were used to combine this extracted information. The first approach, known as feature fusion, involves combining features extracted from EEG and heart rate variability (HRV) into a single feature vector prior to feeding it to a classifier. The second approach, called classifier or decision fusion, is achieved by combining the independent decisions of the EEG and the HRV-based classifiers. Tested on recordings obtained from eight newborns with identified EEG seizures, the proposed neonatal seizure detection algorithms achieved 95.20% sensitivity and 88.60% specificity for the feature fusion case and 95.20% sensitivity and 94.30% specificity for the classifier fusion case. These results are considerably better than those involving classifiers using EEG only (80.90%, 86.50%) or HRV only (85.70%, 84.60%).

  5. Experimental test results of multi-channel test rig of T1 test section, 5

    International Nuclear Information System (INIS)

    Hino, Ryutaro; Takase, Kazuyuki; Miyamoto, Yoshiaki

    1990-09-01

    Channel blockage test on a fuel column of the high temperature engineering test reactor (HTTR) has been performed under the helium gas atmosphere at a high temperature and a high pressure in order to obtain safety data on flow rate and temperature distributions in the fuel column with the multi-channel test rig of the fuel stack test section (T 1 ) in HENDEL. In the test, one of 12 fuel channels was blockaded to 90% of flow area at the channel inlet. Experimental results showed that the helium gas flow rate in the blockaded channel was 28%∼33% lower than the average flow rate for Reynolds number from 2300 to 14000 in isothermal flow. When simulated fuel rods were heated, the flow rate in the blockaded channel did not decrease down in comparison with the isothermal flow. This is due to that the heat generated in the fuel rods conducts to the other fuel channels in graphite fuel blocks, so that accelerated pressure losses in the fuel channels change with helium gas temperatures. (author)

  6. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  7. The Research of China's Civil Aviation Passenger Multi-Channel Service Technology Platform

    Science.gov (United States)

    Zhibing, Xue; Xinming, Wang

    IATA is promoting Simplifying the Business. The traditional passenger services and business process, such as ticketing, airport counters, had a great influence. The airlines have the passenger service and convenience as the next product development requirements. With civil aviation industry and their company's products construction, the authors propose a solution of passenger multi-channel service product platform. The solution is to streamline the business as the breakthrough point, around the convenience of passengers travel services to travelers as the center, using the current mainstream and the latest IT technology to establish passenger service product platform. The solution will promote DCS e-ticketing business development and service channel diversity. In this paper, the research results have been applied in the product platform construction of the authors' company. The practice shows that through traditional business with the latest IT technologies, traditional passenger services into the emerging service model, passenger service product platform has strong advantages and characteristics. Based on the platform, various types of service products is growing rapidly.

  8. Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary

    Science.gov (United States)

    Shaha, Dinesh Chandra; Cho, Yang-Ki

    2016-01-01

    Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892

  9. A multi-channel model for an α plus {sup 6}He nucleus cluster

    Energy Technology Data Exchange (ETDEWEB)

    Amos, K.; Karataglidis, S. [University of Melbourne, School of Physics, Victoria (Australia); University of Johannesburg, Department of Physics, Auckland Park (South Africa); Canton, L. [Istituto Nazionale di Fisica Nucleare, Padova (Italy); Fraser, P.R. [Curtin University, Department of Physics, Astronomy and Medical Radiation Sciences, Perth (Australia); Svenne, J.P. [Department of Physics and Astronomy, University of Manitoba, and Winnipeg Institute for Theoretical Physics, Winnipeg, MB (Canada); Van der Knijff, D. [University of Melbourne, School of Physics, Victoria (Australia)

    2017-04-15

    A multi-channel algebraic scattering (MCAS) method has been used to solve coupled sets of Lippmann-Schwinger equations for the α + {sup 6}He cluster system, so finding a model spectrum for {sup 10}Be to more than 10MeV excitation. Three states of {sup 6}He were included and the resonance character of the two excited states taken into account in finding solutions. A model Hamiltonian has been found that gives very good agreement with the known bound states and with some low-lying resonances of {sup 10}Be. More resonance states are predicted than those which have been observed as yet. The method also yields S-matrices which we have used to evaluate low-energy {sup 6}He-α scattering cross sections. Reasonable reproduction of low-energy differential cross sections and of energy variation of cross sections measured at fixed scattering angles have been found. Enlarging the channel space by including two higher energy states of {sup 6}He, assuming values for their spin-parities, leads to an enlarged spectrum for {sup 10}Be in which the number and distribution of resonances show similarity to the known spectrum. (orig.)

  10. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  11. Superpixel-based segmentation of muscle fibers in multi-channel microscopy.

    Science.gov (United States)

    Nguyen, Binh P; Heemskerk, Hans; So, Peter T C; Tucker-Kellogg, Lisa

    2016-12-05

    Confetti fluorescence and other multi-color genetic labelling strategies are useful for observing stem cell regeneration and for other problems of cell lineage tracing. One difficulty of such strategies is segmenting the cell boundaries, which is a very different problem from segmenting color images from the real world. This paper addresses the difficulties and presents a superpixel-based framework for segmentation of regenerated muscle fibers in mice. We propose to integrate an edge detector into a superpixel algorithm and customize the method for multi-channel images. The enhanced superpixel method outperforms the original and another advanced superpixel algorithm in terms of both boundary recall and under-segmentation error. Our framework was applied to cross-section and lateral section images of regenerated muscle fibers from confetti-fluorescent mice. Compared with "ground-truth" segmentations, our framework yielded median Dice similarity coefficients of 0.92 and higher. Our segmentation framework is flexible and provides very good segmentations of multi-color muscle fibers. We anticipate our methods will be useful for segmenting a variety of tissues in confetti fluorecent mice and in mice with similar multi-color labels.

  12. Measurements of void fraction by an improved multi-channel conductance void meter

    International Nuclear Information System (INIS)

    Song, Chul-Hwa; Chung, Moon Ki; No, Hee Cheon

    1998-01-01

    An improved multi-channel Conductance Void Meter (CVM) was developed to measure a void fraction. Its measuring principle is basically based upon the differences of electrical conductance of a two-phase mixture due to the variation of void fraction around a sensor. The sensor is designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. It is emphasized that the guard electrodes are electrically shielded in order not to affect the measurements of two-phase mixture conductance, but to make the electric fields evenly distributed in a measuring volume. Void fraction is measured for bubbly and slug flow regimes in a vertical air-water loop, and statistical signal processing techniques are applied to show that CVM has a good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel. (author)

  13. Concept and Development Status of the Digital Upgrade of the Mini Multi-Channel Analyser (DMCA)

    International Nuclear Information System (INIS)

    Brutscher, J.; Birnbaum, A.; Keubler, J.; Jung, S.; Koestlbauer, M.; Richter, B.; Schwalbach, P.; Zweidorf, A. von

    2010-01-01

    The Mini Multi Channel Analyser (MMCA) is a portable electronics module used for neutron and gamma ray Non-Destructive Assay (NDA) of nuclear material. The MMCA is widely used in nuclear safeguards to perform certain classes of verification activities on nuclear material. For more than a decade, an important but non-exclusive area of application has been low- and medium-resolution gamma spectroscopy and attribute testing. To make use of advances in digital technology, communication protocols and standardisation, display technology, and user interaction paradigms, while preserving the main functionality and compatibility with the existing MMCA, a digital upgrade of the MMCA (DMCA) is being developed in the frame of the German Support Programme to the International Atomic Energy Agency (IAEA) with cooperation of the European Commission. The DMCA is dubbed MCA-527. At the same time, a data acquisition and analysis software interface optimized for in-field use is being developed (''MCAtouch''). In this paper, development status and performance parameters of the digital MCA-527 as well as the software interface MCAtouch are discussed in the context of safeguards requirements for typical in-field applications. (author)

  14. Subjective evaluation of auralizations created from multi-channel anechoic recordings of a talker in motion

    Science.gov (United States)

    Vigeant, Michelle C.; Wang, Lily M.

    2005-04-01

    A high degree of speech intelligibility is very important in educational environments. When designing such spaces, like classrooms, auralizations can be used to subjectively assess the degree of speech intelligibility and clarity. Auralizations are most commonly made by convolving the impulse response (IR) of an omni-directional source with a single channel anechoic speech recording. This paper explores the idea of using multi-channel recordings to create the auralizations, using a female talker in motion. An omni-directional source is split into quadrants and the IR is calculated for each section. These IR's are convolved with the appropriate channel of the anechoic recording and then the four auralizations are mixed to create one final auralization. The auralizations were made using four-channel anechoic recordings of a person walking on a platform while talking. Subjective tests were conducted to determine the ease with which subjects could identify the direction of the movement of the source in rooms with varying amounts of absorption. This method can be used to create more realistic classroom auralizations, as teachers typically move around the room as they teach. [Work supported by the National Science Foundation.

  15. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  16. Hyperbolic Positioning with Antenna Arrays and Multi-Channel Pseudolite for Indoor Localization

    Directory of Open Access Journals (Sweden)

    Kenjirou Fujii

    2015-09-01

    Full Text Available A hyperbolic positioning method with antenna arrays consisting of proximately-located antennas and a multi-channel pseudolite is proposed in order to overcome the problems of indoor positioning with conventional pseudolites (ground-based GPS transmitters. A two-dimensional positioning experiment using actual devices is conducted. The experimental result shows that the positioning accuracy varies centimeter- to meter-level according to the geometric relation between the pseudolite antennas and the receiver. It also shows that the bias error of the carrier-phase difference observables is more serious than their random error. Based on the size of the bias error of carrier-phase difference that is inverse-calculated from the experimental result, three-dimensional positioning performance is evaluated by computer simulation. In addition, in the three-dimensional positioning scenario, an initial value convergence analysis of the non-linear least squares is conducted. Its result shows that initial values that can converge to a right position exist at least under the proposed antenna setup. The simulated values and evaluation methods introduced in this work can be applied to various antenna setups; therefore, by using them, positioning performance can be predicted in advance of installing an actual system.

  17. Reprocessing of multi-channel seismic-reflection data collected in the Beaufort Sea

    Science.gov (United States)

    Agena, W.F.; Lee, Myung W.; Hart, P.E.

    2000-01-01

    Contained on this set of two CD-ROMs are stacked and migrated multi-channel seismic-reflection data for 65 lines recorded in the Beaufort Sea by the United States Geological Survey in 1977. All data were reprocessed by the USGS using updated processing methods resulting in improved interpretability. Each of the two CD-ROMs contains the following files: 1) 65 files containing the digital seismic data in standard, SEG-Y format; 2) 1 file containing navigation data for the 65 lines in standard SEG-P1 format; 3) an ASCII text file with cross-reference information for relating the sequential trace numbers on each line to cdp numbers and shotpoint numbers; 4) 2 small scale graphic images (stacked and migrated) of a segment of line 722 in Adobe Acrobat (R) PDF format; 5) a graphic image of the location map, generated from the navigation file; 6) PlotSeis, an MS-DOS Application that allows PC users to interactively view the SEG-Y files; 7) a PlotSeis documentation file; and 8) an explanation of the processing used to create the final seismic sections (this document).

  18. Multi-Channel RF System for MRI-Guided Transurethral Ultrasound Thermal Therapy

    Science.gov (United States)

    Yak, Nicolas; Asselin, Matthew; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound thermal therapy is an approach to treating localized prostate cancer which targets precise deposition of thermal energy within a confined region of the gland. This treatment requires a system incorporating a heating applicator with multiple planar ultrasound transducers and associated RF electronics to control individual elements independently in order to achieve accurate 3D treatment. We report the design, construction, and characterization of a prototype multi-channel system capable of controlling 16 independent RF signals for a 16-element heating applicator. The main components are a control computer, microcontroller, and a 16-channel signal generator with 16 amplifiers, each incorporating a low-pass filter and transmitted/reflected power detection circuit. Each channel can deliver from 0.5 to 10 W of electrical power and good linearity from 3 to 12 MHz. Harmonic RF signals near the Larmor frequency of a 1.5 T MRI were measured to be below -30 dBm and heating experiments within the 1.5 T MR system showed no significant decrease in SNR of the temperature images. The frequency and power for all 16 channels could be changed in less than 250 ms, which was sufficiently rapid for proper performance of the control algorithms. A common backplane design was chosen which enabled an inexpensive, modular approach for each channel resulting in an overall system with minimal footprint.

  19. A multi-channel magnetic induction tomography measurement system for human brain model imaging

    International Nuclear Information System (INIS)

    Xu, Zheng; Luo, Haijun; He, Wei; He, Chuanhong; Song, Xiaodong; Zahng, Zhanglong

    2009-01-01

    This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in a human brain model. A hemispherical glass bowl filled with a salt solution is used as the human brain model; meanwhile, agar blocks of different conductivity are placed in the solution to simulate the intracerebral hemorrhage. The excitation and detection coils are fixed co-axially, and the axial gradiometer is used as the detection coil in order to cancel the primary field. On the outer surface of the glass bowl, 15 sensor units are arrayed in two circles as measurement parts, and a single sensor unit for canceling the phase drift is placed beside the glass bowl. The phase sensitivity of our system is 0.204°/S m −1 with the excitation frequency of 120 kHz and the phase noise is in the range of −0.03° to +0.05°. Only the coaxial detection coil is available for each excitation coil; therefore, 15 phase data are collected in each measurement turn. Finally, the two-dimensional images of conductivity distribution are obtained using an interpolation algorithm. The frequency-varying experiment indicates that the imaging quality becomes better as the excitation frequency is increased

  20. Automated Filtering of Common Mode Artifacts in Multi-Channel Physiological Recordings

    Science.gov (United States)

    Kelly, John W.; Siewiorek, Daniel P.; Smailagic, Asim; Wang, Wei

    2014-01-01

    The removal of spatially correlated noise is an important step in processing multi-channel recordings. Here, a technique termed the adaptive common average reference (ACAR) is presented as an effective and simple method for removing this noise. The ACAR is based on a combination of the well-known common average reference (CAR) and an adaptive noise canceling (ANC) filter. In a convergent process, the CAR provides a reference to an ANC filter, which in turn provides feedback to enhance the CAR. This method was effective on both simulated and real data, outperforming the standard CAR when the amplitude or polarity of the noise changes across channels. In many cases the ACAR even outperformed independent component analysis (ICA). On 16 channels of simulated data the ACAR was able to attenuate up to approximately 290 dB of noise and could improve signal quality if the original SNR was as high as 5 dB. With an original SNR of 0 dB, the ACAR improved signal quality with only two data channels and performance improved as the number of channels increased. It also performed well under many different conditions for the structure of the noise and signals. Analysis of contaminated electrocorticographic (ECoG) recordings further showed the effectiveness of the ACAR. PMID:23708770

  1. Multi-channel Spiral Twist Extrusion (MCSTE): A Novel Severe Plastic Deformation Technique for Grain Refinement

    Science.gov (United States)

    El-Garaihy, W. H.; Fouad, D. M.; Salem, H. G.

    2018-04-01

    Multi-channel Spiral Twist Extrusion (MCSTE) is introduced as a novel severe plastic deformation (SPD) technique for producing superior mechanical properties associated with ultrafine grained structure in bulk metals and alloys. The MCSTE design is based on inserting a uniform square cross-sectioned billet within stacked disks that guarantee shear strain accumulation. In an attempt to validate the technique and evaluate its plastic deformation characteristics, a series of experiments were conducted. The influence of the number of MCSTE passes on the mechanical properties and microstructural evolution of AA1100 alloy were investigated. Four passes of MCSTE, at a relatively low twisting angle of 30 deg, resulted in increasing the strength and hardness coupled with retention of ductility. Metallographic observations indicated a significant grain size reduction of 72 pct after 4 passes of MCSTE compared with the as-received (AR) condition. Moreover, the structural uniformity increased with the number of passes, which was reflected in the hardness distribution from the peripheries to the center of the extrudates. The current study showed that the MCSTE technique could be an effective, adaptable SPD die design with a promising potential for industrial applications compared to its counterparts.

  2. The Over-Barrier Resonant States and Multi-Channel Scattering in Multiple Quantum Wells

    Directory of Open Access Journals (Sweden)

    A Polupanov

    2016-09-01

    Full Text Available We demonstrate an explicit numerical method for accurate calculation of the scattering matrix and its poles, and apply this method to describe the multi-channel scattering in the multiple quantum-wells structures. The S-matrix is continued analytically to the unphysical region of complex energy values. Results of calculations show that there exist one or more S-matrix poles, corresponding to the over-barrier resonant states critical for the effect of the absolute reflection of holes in the energy range where only the heavy ones may propagate over barriers in a structure. Light- and heavy-hole states are described by the Luttinger Hamiltonian matrix. In contrast to the single quantum-well case, at some parameters of a multiple quantum-wells structure the number of S-matrix poles may exceed that of the absolute reflection peaks, and at different values of parameters the absolute reflection peak corresponds to different resonant states. The imaginary parts of the S-matrix poles and hence the lifetimes of resonant states as well as the widths of resonant peaks of absolute reflection depend drastically on the quantum-well potential depth. In the case of shallow quantum wells there is in fact a long-living over-barrier resonant hole state.

  3. A multi-channel time-to-digital converter chip for drift chamber readout

    International Nuclear Information System (INIS)

    Chau, A.; DeBusschere, D.; Dow, S.F.; Flasck, J.; Levi, M.E.; Kirsten, F.; Su, E.; Santos, D.M.

    1996-01-01

    A complete, multi-channel, timing and amplitude measurement IC for use in drift chamber applications is described. By targeting specific resolutions, i.e., 6-bits of resolution for both time and amplitude, area and power can be minimized while achieving the proper level of measurement accuracy. Time is digitized using an TDC comprised of a delay locked loop, latch and encoder. Amplitude (for dE/dx) is digitized using a dual-range FADC for each channel. Eight bits of dynamic range with six bits of accuracy are achieved with the dual-range. Eight complete channels of timing and amplitude information are multiplexed into one DRAM (Dynamic Random Access Memory) trigger latency buffer. Interesting events are subsequently transferred into an SRAM (Static Random Access Memory) readout buffer before the latency time has expired. The design has been optimized to achieve the requisite resolution using the smallest area and lowest power. The circuit has been implemented in an 0.8 microm triple metal CMOS process. The measured results indicate that the differential non-linearities of the TDC and the FADC are 200 ps and 10 mV, respectively. The integral nonlinearities of the TDC and the FADC are 230 ps and 9 mV, respectively

  4. Development of a Multi-Channel Piezoelectric Acoustic Sensor Based on an Artificial Basilar Membrane

    Directory of Open Access Journals (Sweden)

    Youngdo Jung

    2013-12-01

    Full Text Available In this research, we have developed a multi-channel piezoelectric acoustic sensor (McPAS that mimics the function of the natural basilar membrane capable of separating incoming acoustic signals mechanically by their frequency and generating corresponding electrical signals. The McPAS operates without an external energy source and signal processing unit with a vibrating piezoelectric thin film membrane. The shape of the vibrating membrane was chosen to be trapezoidal such that different locations of membrane have different local resonance frequencies. The length of the membrane is 28 mm and the width of the membrane varies from 1 mm to 8 mm. Multiphysics finite element analysis (FEA was carried out to predict and design the mechanical behaviors and piezoelectric response of the McPAS model. The designed McPAS was fabricated with a MEMS fabrication process based on the simulated results. The fabricated device was tested with a mouth simulator to measure its mechanical and piezoelectrical frequency response with a laser Doppler vibrometer and acoustic signal analyzer. The experimental results show that the as fabricated McPAS can successfully separate incoming acoustic signals within the 2.5 kHz–13.5 kHz range and the maximum electrical signal output upon acoustic signal input of 94 dBSPL was 6.33 mVpp. The performance of the fabricated McPAS coincided well with the designed parameters.

  5. A wireless multi-channel recording system for freely behaving mice and rats.

    Science.gov (United States)

    Fan, David; Rich, Dylan; Holtzman, Tahl; Ruther, Patrick; Dalley, Jeffrey W; Lopez, Alberto; Rossi, Mark A; Barter, Joseph W; Salas-Meza, Daniel; Herwik, Stanislav; Holzhammer, Tobias; Morizio, James; Yin, Henry H

    2011-01-01

    To understand the neural basis of behavior, it is necessary to record brain activity in freely moving animals. Advances in implantable multi-electrode array technology have enabled researchers to record the activity of neuronal ensembles from multiple brain regions. The full potential of this approach is currently limited by reliance on cable tethers, with bundles of wires connecting the implanted electrodes to the data acquisition system while impeding the natural behavior of the animal. To overcome these limitations, here we introduce a multi-channel wireless headstage system designed for small animals such as rats and mice. A variety of single unit and local field potential signals were recorded from the dorsal striatum and substantia nigra in mice and the ventral striatum and prefrontal cortex simultaneously in rats. This wireless system could be interfaced with commercially available data acquisition systems, and the signals obtained were comparable in quality to those acquired using cable tethers. On account of its small size, light weight, and rechargeable battery, this wireless headstage system is suitable for studying the neural basis of natural behavior, eliminating the need for wires, commutators, and other limitations associated with traditional tethered recording systems.

  6. A wireless multi-channel recording system for freely behaving mice and rats.

    Directory of Open Access Journals (Sweden)

    David Fan

    Full Text Available To understand the neural basis of behavior, it is necessary to record brain activity in freely moving animals. Advances in implantable multi-electrode array technology have enabled researchers to record the activity of neuronal ensembles from multiple brain regions. The full potential of this approach is currently limited by reliance on cable tethers, with bundles of wires connecting the implanted electrodes to the data acquisition system while impeding the natural behavior of the animal. To overcome these limitations, here we introduce a multi-channel wireless headstage system designed for small animals such as rats and mice. A variety of single unit and local field potential signals were recorded from the dorsal striatum and substantia nigra in mice and the ventral striatum and prefrontal cortex simultaneously in rats. This wireless system could be interfaced with commercially available data acquisition systems, and the signals obtained were comparable in quality to those acquired using cable tethers. On account of its small size, light weight, and rechargeable battery, this wireless headstage system is suitable for studying the neural basis of natural behavior, eliminating the need for wires, commutators, and other limitations associated with traditional tethered recording systems.

  7. The development of a digital multi-channel pulse height analysis

    International Nuclear Information System (INIS)

    Huang Shanshan; Sang Ziru; Liang Futian; Chen Lian; Liang Hao; Jin Ge

    2012-01-01

    A kind of digital multi-channel analyzer which was developed for Nuclear and Particle Experiment of Undergraduate Student in university was introduced. The input signal is digitalized with a high speed ADC, and feed to a FPGA for seeking peak, recording, spectrometer processing and displaying automatically. The principle of digital searching peck was given in the paper. In order to improve the capability of anti-noise, a dual digital thresholds and dual buffer memories was designed. Aiming at the influence of nonlinear of ADC to the system, a revised algorithm was designed to ensure the channel width uniformity. Since the huge sampling and storaging data of MCA, a method of parallel work of double memory was used, just separated empty transmit data and stored count, reduced the dead time and data overflowing. The host computer can set up and monitor MCA real-time, read and write data from MCA by an USB interface. Contrasts commercial MCA, the MCA has a good result in function and price. (authors)

  8. Binaural unmasking of multi-channel stimuli in bilateral cochlear implant users.

    Science.gov (United States)

    Van Deun, Lieselot; van Wieringen, Astrid; Francart, Tom; Büchner, Andreas; Lenarz, Thomas; Wouters, Jan

    2011-10-01

    Previous work suggests that bilateral cochlear implant users are sensitive to interaural cues if experimental speech processors are used to preserve accurate interaural information in the electrical stimulation pattern. Binaural unmasking occurs in adults and children when an interaural delay is applied to the envelope of a high-rate pulse train. Nevertheless, for speech perception, binaural unmasking benefits have not been demonstrated consistently, even with coordinated stimulation at both ears. The present study aimed at bridging the gap between basic psychophysical performance on binaural signal detection tasks on the one hand and binaural perception of speech in noise on the other hand. Therefore, binaural signal detection was expanded to multi-channel stimulation and biologically relevant interaural delays. A harmonic complex, consisting of three sinusoids (125, 250, and 375 Hz), was added to three 125-Hz-wide noise bands centered on the sinusoids. When an interaural delay of 700 μs was introduced, an average BMLD of 3 dB was established. Outcomes are promising in view of real-life benefits. Future research should investigate the generalization of the observed benefits for signal detection to speech perception in everyday listening situations and determine the importance of coordination of bilateral speech processors and accentuation of envelope cues.

  9. Theoretical Valuation of Multi-Channel Cyclone to Reduce Gas Flow Dustiness in Agressive Environment

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2016-10-01

    Full Text Available Contaminated gas cleaning from finely divided solids is carried out using a new generation of multi-channel design cyclones. The application of these devices are separated and precipitated particles with a minimum diameter up to 2 micrometers, reaching up to 95% cleaning efficiency. Cyclones of such constructions are usually used under usual conditions at elevated temperature and low humidity. Under aggressive conditions, these devices can be clogged, and their recovery is not possible. Further studies are research into the application of constructive solutions to adapt the cyclone gas cleaning of the particulate matter under aggressive conditions. This theoretical evaluation has described the characteristics change of gas flow and particulate matters at different aggressive environment. Such conditions were loudly describe the gas-flow high-temperature range of 50–200 °C and gas-vapor stream, the humidity reaches 70–100%. Estimated aggressive conditions on the gas flow dynamics forces – pressure, resistance and centrifugal, and particulate mechanical – gravitational and adhesion strength. All parameters are evaluated in comparison with the values under normal conditions.

  10. Centralized Routing and Scheduling Using Multi-Channel System Single Transceiver in 802.16d

    Science.gov (United States)

    Al-Hemyari, A.; Noordin, N. K.; Ng, Chee Kyun; Ismail, A.; Khatun, S.

    This paper proposes a cross-layer optimized strategy that reduces the effect of interferences from neighboring nodes within a mesh networks. This cross-layer design relies on the routing information in network layer and the scheduling table in medium access control (MAC) layer. A proposed routing algorithm in network layer is exploited to find the best route for all subscriber stations (SS). Also, a proposed centralized scheduling algorithm in MAC layer is exploited to assign a time slot for each possible node transmission. The cross-layer optimized strategy is using multi-channel single transceiver and single channel single transceiver systems for WiMAX mesh networks (WMNs). Each node in WMN has a transceiver that can be tuned to any available channel for eliminating the secondary interference. Among the considered parameters in the performance analysis are interference from the neighboring nodes, hop count to the base station (BS), number of children per node, slot reuse, load balancing, quality of services (QoS), and node identifier (ID). Results show that the proposed algorithms significantly improve the system performance in terms of length of scheduling, channel utilization ratio (CUR), system throughput, and average end to end transmission delay.

  11. Multi-channel data acquisition and processing system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Jin Ge; Yang Yanming

    1987-01-01

    A multi-channel data acquisition and processing system for moessbauer spectroscopy is described, which consists of an intelligent interface and a BC3-80 microcomputer. The system has eight data channels, each channel contains a counting circuit and a memory. A Z80-CPU is used as a main unit for control and access. The microcomputer is used for real-time displaying spectrum, saving the data to disk, printing data and data processing. The system is applicable to a high counting rate multi-wire proportional chamber. It can increase greatly the counting rate for measuring moessbauer spectrum. The signals of each wire in the chamber go through a corresponding amplifier and a differential discriminator and are recorded by a corresponding data channel, the data of each channel is added by the microcomputer. In addition, two channels can be used to measure an absorption and a scattering spectrum at the same time and the internal and the surface information of the sample are obtained simultaneously

  12. Super-pixel extraction based on multi-channel pulse coupled neural network

    Science.gov (United States)

    Xu, GuangZhu; Hu, Song; Zhang, Liu; Zhao, JingJing; Fu, YunXia; Lei, BangJun

    2018-04-01

    Super-pixel extraction techniques group pixels to form over-segmented image blocks according to the similarity among pixels. Compared with the traditional pixel-based methods, the image descripting method based on super-pixel has advantages of less calculation, being easy to perceive, and has been widely used in image processing and computer vision applications. Pulse coupled neural network (PCNN) is a biologically inspired model, which stems from the phenomenon of synchronous pulse release in the visual cortex of cats. Each PCNN neuron can correspond to a pixel of an input image, and the dynamic firing pattern of each neuron contains both the pixel feature information and its context spatial structural information. In this paper, a new color super-pixel extraction algorithm based on multi-channel pulse coupled neural network (MPCNN) was proposed. The algorithm adopted the block dividing idea of SLIC algorithm, and the image was divided into blocks with same size first. Then, for each image block, the adjacent pixels of each seed with similar color were classified as a group, named a super-pixel. At last, post-processing was adopted for those pixels or pixel blocks which had not been grouped. Experiments show that the proposed method can adjust the number of superpixel and segmentation precision by setting parameters, and has good potential for super-pixel extraction.

  13. Lipoatrofia semicircular: un nuevo trastorno de salud relacionado con el trabajo Semicircular lipoatrophy: a new occupational disease

    Directory of Open Access Journals (Sweden)

    Helena Pañella

    2008-02-01

    Full Text Available En febrero de 2007, una gran empresa de Barcelona notificó un brote de una rara lesión llamada lipoatrofia semicircular que afectaba a casi 200 personas de los aproximadamente 1.000 trabajadores de plantilla. En septiembre de ese mismo año se habían notificado más de 600 casos, también en otros centros de trabajo, sobre todo de Barcelona pero también del resto de España. Se realizó un estudio de casos y controles que identificó como factores de riesgo de esta lesión la baja humedad relativa del interior de los edificios y la utilización de mesas de trabajo con bordes delgados y angulares. Cuatro meses después de notificarse los primeros casos, se presentó un protocolo de actuación ante casos de lipoatrofia dirigido a los profesionales sanitarios de los servicios de prevención de las empresas y de las mutuas de accidentes de trabajo y de enfermedades profesionales. La implantación de estas medidas de control se ha traducido en una drástica reducción de la incidencia y en la curación de una proporción significativa de los casos.In February 2007, an outbreak of 200 cases of a rare condition called semicircular lipoatrophy was notified by a company of Barcelona with about 1,000 workers. In September of that year, more that 600 cases had been notified in other workplaces, most of them in Barcelona, but also in other Spanish cities. A case-control study identified the low indoor relative humidity and working tables with thin edges as risk factors. Four months after the onset of the outbreak, the guidelines for the management of similar work-related outbreaks were published. They were addressed to health care workers of occupational health services and insurance organisations of occupational injuries and professional diseases. The implementation of the recommended interventions has been followed by a dramatic reduction of the incidence of new cases as well as by the recovery of a significant proportion of cases.

  14. A strategy for determination of test intervals of k-out-of-n multi-channel systems

    International Nuclear Information System (INIS)

    Cho, S.; Jiang, J.

    2007-01-01

    State space models for determination of the optimal test frequencies for k-out-of-n multi channel systems are developed in this paper. The analytic solutions for the optimal surveillance test frequencies are derived using the Markov process technique. The solutions show that an optimal test frequency which maximizes the target probability can be determined by decomposing the system states to 3 states based on the system configuration and success criteria. Examples of quantification of the state probabilities and the optimal test frequencies of a three-channel system and a four-channel system with different success criteria are presented. The strategy for finding the optimal test frequency developed in this paper can generally be applicable to any k-out-of-n multi-channel standby systems that involve complex testing schemes. (author)

  15. Operational Criteria for the Design of Front-Office Processes in Multi-Channel Service Delivery Systems

    OpenAIRE

    Sousa, Rui; Amorim, Marlene

    2010-01-01

    This paper identifies relevant operational factors that affect the design of front-office processes in Multi-Channel Service Delivery Systems. Based on two in-depth case studies in banking and telecommunications, we distinguish four operational factors: i) characteristics of the inputs and outputs of the service activities; ii) characteristics of the transformation taking place; iii) the expected utilization; iv) the economics of developing the activities in the channels. Building on these re...

  16. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI.

    Science.gov (United States)

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, Michal; Standara, Michal; Starčuk, Zenon; Taxt, Torfinn

    2016-03-01

    One of the main challenges in quantitative dynamic contrast-enhanced (DCE) MRI is estimation of the arterial input function (AIF). Usually, the signal from a single artery (ignoring contrast dispersion, partial volume effects and flow artifacts) or a population average of such signals (also ignoring variability between patients) is used. Multi-channel blind deconvolution is an alternative approach avoiding most of these problems. The AIF is estimated directly from the measured tracer concentration curves in several tissues. This contribution extends the published methods of multi-channel blind deconvolution by applying a more realistic model of the impulse residue function, the distributed capillary adiabatic tissue homogeneity model (DCATH). In addition, an alternative AIF model is used and several AIF-scaling methods are tested. The proposed method is evaluated on synthetic data with respect to the number of tissue regions and to the signal-to-noise ratio. Evaluation on clinical data (renal cell carcinoma patients before and after the beginning of the treatment) gave consistent results. An initial evaluation on clinical data indicates more reliable and less noise sensitive perfusion parameter estimates. Blind multi-channel deconvolution using the DCATH model might be a method of choice for AIF estimation in a clinical setup. © 2015 Wiley Periodicals, Inc.

  17. Experimental researches and comparison on aerodynamic parameters and cleaning efficiency of multi-level multi-channel cyclone

    Directory of Open Access Journals (Sweden)

    Aleksandras Chlebnikovas

    2015-10-01

    Full Text Available Multi-level multi-channel cyclone – the lately designed air cleaning device that can remove ultra-fine 20 μm particulatematter (PM from dusted air and reach over 95% of the overall cleaning efficiency. Multi-channel cyclone technology is based on centrifugal forces and has the resulting additional filtering process operation. Multi-level structure of cyclone allows to achieve higher air flow cleaning capacity at the same dimensions of the device, thus saving installation space required for the job, production and operating costs. Studies have examined the air flow parameters change in one–, two– and three–levels multichannel cyclone. These constructions differ according to the productivity of cleaned air under the constant peripheral and transitional (50/50 case air flow relations. Accordance with the results of air flow dynamics – velocity distribution of multi-channel cyclone, aerodynamic resistance and efficiency can be judged on the flow turbulence, the flow channel cross-section and select the most appropriate application. Cleaning efficiency studies were carried out using fine granite and wood ashes PM. The maximum cleaning efficiency was 93.3%, at an average of 4.5 g/m3, the aerodynamic resistance was equal to 1525 Pa.

  18. Development of multi-channel optical-fiber feed through for ITER

    International Nuclear Information System (INIS)

    Sugie, Tatsuo; Kasai, Satoshi; Toriya, Tomoaki

    1998-08-01

    A multi-channel fiber feed through has been developed for visible and IR transmission lines through secondary vacuum boundary (cryostat boundary) of ITER. In the first phase, a scale down test-module which has ten fiber feed through in the vacuum flange was manufactured and tested. The vacuum seal was realized by soldering gold plated fibers to a vacuum flange with high temperature solder. The capacity to resist inner pressure rise of 5 atm, the acceleration resistant of 15g and the temperature resistant from 20degC-200degC were achieved by the test module. The connecting loss and the uniformity of transmission losses among each channels of the feed through were not well. Concerning the connecting loss, the best value was 2.2 dB and the worst one was 13.5 dB. In the second phase, the full performance test-module which has 57 fiber feed through was manufactured and tested. The feed through was improved in order to achieve a good transmission and the uniformity among each channels by using a optical fiber implanted in a center of a quartz rod very accurately. The capacity to resist inner pressure rise of 5 atm, the acceleration resistant of 15g and the temperature resistant from 40degC-200degC (Temperature ramp rate: >20degC/hr) were achieved by the full performance test-module. The connecting losses of the feed through were less than 3 dB, and the uniformity of transmission losses among each channels of the feed through was larger than 60%. The requirements for an optical-fiber feed through were almost satisfied with the full performance test-module. Further developments will be necessary for the remote handling method. (author)

  19. Time-varying bispectral analysis of visually evoked multi-channel EEG

    Science.gov (United States)

    Chandran, Vinod

    2012-12-01

    Theoretical foundations of higher order spectral analysis are revisited to examine the use of time-varying bicoherence on non-stationary signals using a classical short-time Fourier approach. A methodology is developed to apply this to evoked EEG responses where a stimulus-locked time reference is available. Short-time windowed ensembles of the response at the same offset from the reference are considered as ergodic cyclostationary processes within a non-stationary random process. Bicoherence can be estimated reliably with known levels at which it is significantly different from zero and can be tracked as a function of offset from the stimulus. When this methodology is applied to multi-channel EEG, it is possible to obtain information about phase synchronization at different regions of the brain as the neural response develops. The methodology is applied to analyze evoked EEG response to flash visual stimulii to the left and right eye separately. The EEG electrode array is segmented based on bicoherence evolution with time using the mean absolute difference as a measure of dissimilarity. Segment maps confirm the importance of the occipital region in visual processing and demonstrate a link between the frontal and occipital regions during the response. Maps are constructed using bicoherence at bifrequencies that include the alpha band frequency of 8Hz as well as 4 and 20Hz. Differences are observed between responses from the left eye and the right eye, and also between subjects. The methodology shows potential as a neurological functional imaging technique that can be further developed for diagnosis and monitoring using scalp EEG which is less invasive and less expensive than magnetic resonance imaging.

  20. MULTI-CHANNEL VOLUME SPHYGMOGRAPHY IN CARDIOANGIOLOGICAL SCREENING OF THE ADULT POPULATION

    Directory of Open Access Journals (Sweden)

    R. A. Khokhlov

    2015-01-01

    Full Text Available Aim. To study the possibilities of using multi-channel volume sphygmography (MCVS in prophylactic medical examination of the population.Material and methods. Simultaneous examination of 522 individuals older than 18 years was performed. Along with standard procedures provided by the prophylactic medical examination program synchronous registration of blood pressure (BP on four extremities by MCVS was performed. At that a difference in systolic BP between arms (ΔSBParm and legs (ΔSBPleg and ankle-brachial index (ABI were automatically calculated. Values of │ΔSBParm│ or │ΔSBPleg│≥15 mm Hg or ABI≤0.9 were considered as markers of atherosclerotic vascular disease.Results. Signs of peripheral arterial atherosclerotic lesions among patients ≥40 years old were found in 14.7% of the cases (95% confidence interval [CI] 11.7-18.4. Relative risks of atherosclerotic lesions in arteries increase 1.71-fold (95% CI 1.06-2.74 in arterial hypertension, 1.70-fold (95% CI 1.08-2.68 – in obesity, 1.91 fold (95% CI 1.17-3.12 – in diabetes, as well as with the increasing levels of cardiovascular risk. In patients with ischemic heart disease and a history of cerebral stroke MCVS can detect signs of multifocal atherosclerosis in 21% (95% CI 14-32 and 22% (95% CI 9-46 of the cases, respectively.Conclusion. MCVS with the determination of ΔSBParm, ΔSBPleg and ABI may be regarded as the basis for low-cost and efficient system of cardioangiological screening.

  1. MULTI-CHANNEL VOLUME SPHYGMOGRAPHY IN CARDIOANGIOLOGICAL SCREENING OF THE ADULT POPULATION

    Directory of Open Access Journals (Sweden)

    R. A. Khokhlov

    2015-09-01

    Full Text Available Aim. To study the possibilities of using multi-channel volume sphygmography (MCVS in prophylactic medical examination of the population.Material and methods. Simultaneous examination of 522 individuals older than 18 years was performed. Along with standard procedures provided by the prophylactic medical examination program synchronous registration of blood pressure (BP on four extremities by MCVS was performed. At that a difference in systolic BP between arms (ΔSBParm and legs (ΔSBPleg and ankle-brachial index (ABI were automatically calculated. Values of │ΔSBParm│ or │ΔSBPleg│≥15 mm Hg or ABI≤0.9 were considered as markers of atherosclerotic vascular disease.Results. Signs of peripheral arterial atherosclerotic lesions among patients ≥40 years old were found in 14.7% of the cases (95% confidence interval [CI] 11.7-18.4. Relative risks of atherosclerotic lesions in arteries increase 1.71-fold (95% CI 1.06-2.74 in arterial hypertension, 1.70-fold (95% CI 1.08-2.68 – in obesity, 1.91 fold (95% CI 1.17-3.12 – in diabetes, as well as with the increasing levels of cardiovascular risk. In patients with ischemic heart disease and a history of cerebral stroke MCVS can detect signs of multifocal atherosclerosis in 21% (95% CI 14-32 and 22% (95% CI 9-46 of the cases, respectively.Conclusion. MCVS with the determination of ΔSBParm, ΔSBPleg and ABI may be regarded as the basis for low-cost and efficient system of cardioangiological screening.

  2. Take time to make time : What to consider when managing multi-channel sales systems with the objective to increase sales efficiency

    OpenAIRE

    ALM, RAGNAR; KYRÖNLAHTI, RUDY

    2016-01-01

    Traditional sales systems have been disrupted by technological developments. In order to  adapt, companies are changing the way they interact with their customers in business-to-business markets. In the last three decades, multi-channel strategies have spurred the proliferation of different sales channels and new ways of managing sales systems. The purpose of this research was to investigate what should be considered when managing multi-channel sales systems with the objective of increasing s...

  3. Multi-channel programmable power supply with temperature compensation for silicon sensors

    International Nuclear Information System (INIS)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R.; Kurup, A. M.; Lokhandwala, S. S.; Prabhu, S. S.; Freeman, J.; Los, S.; Garde, C. S.; Khandekar, P. D.; Gupta, S. K.; Rakshe, P. S.

    2016-01-01

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  4. Seismarmara experiment: results from reprocessing of selected multi-channel seismic reflection profiles

    Science.gov (United States)

    Cetin, S.; Voogd, B.; Carton, H.; Laigle, M.; Becel, A.; Saatcilar, R.; Singh, S.; Hirn, A.

    2003-04-01

    The North Anatolian Fault (NAF) has been responsible for the earthquakes of Izmit and Duzce in 1999. The occurrence of these earthquakes has drawn scientific attention into the Sea of Marmara since the NAF enters into the Sea of Marmara where the latest Izmit earthquake rupture stopped. The SEISMARMARA-2001 survey is a combined seismic reflection, refraction and earthquake experiment carried out in 2001 in the Marmara Region in Turkey by French-Turkish scientific cooperation. The objectives of this survey were to image the various branches of the NAF and related other fault systems. R/V Le Nadir was equipped with a 4.5 km long streamer with 360 channels and a large airgun source. During Leg 1, a grid of large regional lines encompassing the whole Marmara trough was shot. For part of them a strong 8100 cu.in. source for deepest penetration was used, with a 150 m shot interval giving a 15-fold coverage. Another part was shot for a higher resolution with a 2900 cu. in. array at a 50m or 38 m interval to give a 45 or 60-fold coverage. The latter acquisition parameters were used for Leg 2 that was devoted to a very dense grid of lines in the Cinarcik Basin Reprocessing of the multi-channel seismic data is currently being undertaken in several Institutions using different seismic processing softwares (GeoVecteur, ProMAX, Focus), to take advantage of the diverse acquisitions and cope with their limitations, for instance high fold-order for Leg 2 and strength of signal but loose spatial sampling for the bigger source. The main objectives of the reprocessing of the selected profiles are to do a detailed velocity analysis and stacking after deconvolution, filtering to remove or suppress deep sea bottom multiples and out of plane reflections, and time-migration and depth conversion and thus reveal both the shallow and deeper reflection image of the crust in the Sea of Marmara. We show that choosing an appropriate processing sequence for different sources and acquisition

  5. Multi-channel programmable power supply with temperature compensation for silicon sensors

    Energy Technology Data Exchange (ETDEWEB)

    Shukla, R. A.; Achanta, V. G.; Dugad, S. R., E-mail: dugad@cern.ch; Kurup, A. M.; Lokhandwala, S. S.; Prabhu, S. S. [Tata Institute of Fundamental Research, Mumbai 400005 (India); Freeman, J.; Los, S. [Fermi National Accelerator Laboratory, Batavia, Illinois 60510 (United States); Garde, C. S.; Khandekar, P. D. [Vishwakarma Institute of Information Technology, Pune 411048 (India); Gupta, S. K. [Tata Institute of Fundamental Research, Mumbai 400005 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India); Rakshe, P. S. [Vishwakarma Institute of Information Technology, Pune 411048 (India); GRAPES-3 Experiment, Cosmic Ray Laboratory, Raj Bhavan, Ooty 643001 (India)

    2016-01-15

    Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this

  6. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Guangkai [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001, China and Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Gao, Yaozong; Wu, Guorong [Department of Computer Science, Department of Radiology, and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 (United States); Wu, Ligang [Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin 150001 (China); Shen, Dinggang, E-mail: dgshen@med.unc.edu [Department of Radiology and BRIC, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599 and Department of Brain and Cognitive Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2016-02-15

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  7. Nonlocal atlas-guided multi-channel forest learning for human brain labeling

    International Nuclear Information System (INIS)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-01-01

    Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the

  8. Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

    Science.gov (United States)

    Ma, Guangkai; Gao, Yaozong; Wu, Guorong; Wu, Ligang; Shen, Dinggang

    2016-02-01

    It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. The authors have comprehensively evaluated their method on both public LONI_LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient

  9. Masses and widths of scalar–isoscalar multi-channel resonances from data analysis

    International Nuclear Information System (INIS)

    Surovtsev, Yurii S; Bydžovský, Petr; Kamiński, Robert; Lyubovitskij, Valery E; Nagy, Miroslav

    2014-01-01

    The peculiarities of obtaining parameters for broad multi-channel resonances from data are discussed, analyzing the experimental data on processes ππ→ππ,K K-bar in the I G J PC = 0 + 0 ++ channel in a model-independent approach based on analyticity and unitarity, and using an uniformization procedure. We show that it is possible to obtain a good description of the ππ scattering data from the threshold to 1.89 GeV with parameters of resonances cited in the Particle Data Group tables as preferred. However, in this case, first, the representation of the ππ background is unsatisfactory; second, the data on the coupled process ππ→K K-bar are not well described even qualitatively above 1.15 GeV when using the resonance parameters from only the ππ scattering analysis. The combined analysis of these coupled processes is needed, and is carried out satisfactorily. Then, both of the above-indicated issues related to the analysis of ππ scattering only are overcome. The most remarkable change of parameters with respect to the values of the ππ scattering only analysis appears for the mass of the f 0 (600), which is now in some accordance with the Weinberg prediction on the basis of mended symmetry and with an analysis using the large-N c consistency conditions between the unitarization and resonance saturation. The obtained ππ scattering length a 0 0 , in the case where we are restricted to the analysis of the ππ scattering or where we consider the so-called A-solution (with a lower mass and width of f 0 (600) meson), agrees well with the prediction of the chiral perturbation theory and with data extracted at CERN by the NA48/2 collaboration from the analysis of the K e4 decay and by the DIRAC collaboration from the measurement of the π + π − lifetime. (paper)

  10. Endoscopic root canal treatment.

    Science.gov (United States)

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  11. Multi-channel counter-current chromatography for high-throughput fractionation of natural products for drug discovery.

    Science.gov (United States)

    Wu, Shihua; Yang, Lu; Gao, Yuan; Liu, Xiaoyue; Liu, Feiyan

    2008-02-08

    A multi-channel counter-current chromatography (CCC) method has been designed and fabricated for the high-throughput fractionation of natural products without complications sometimes encountered with other conventional chromatographic systems, such as irreversible adsorptive constituent losses and deactivation, tailing of solute peaks and contamination. It has multiple independent CCC channels and each channel connects independent separation column(s) by parallel flow tubes, and thus the multi-channel CCC apparatus can achieve simultaneously two or more independent chromatographic processes. Furthermore, a high-throughput CCC fractionation method for natural products has been developed by a combination of a new three-channel CCC apparatus and conventional parallel chromatographic devices including pumps, sample injectors, effluent detectors and collectors, and its performance has been displayed on the fractionation of ethyl acetate extracts of three natural materials Solidago canadensis, Suillus placidus, and Trichosanthes kirilowii, which are found to be potent cytotoxic to tumor cell lines in the course of screening the antitumor candidates. By combination of biological screening programs and preparative high-performance liquid chromatography (HPLC) purification, 22.8 mg 6 beta-angeloyloxykolavenic acid and 29.4 mg 6 beta-tigloyloxykolavenic acid for S. canadensis, 25.3mg suillin for S. placidus, and 6.8 mg 23,24-dihydrocucurbitacin B for T. Kirilowii as their major cytotoxic principles were isolated from each 1000 mg crude ethyl acetate extract. Their chemical structures were characterized by electrospray ionization mass spectrometry, one- and two-dimensional nuclear magnetic resonance. The overall results indicate the multi-channel CCC is very useful for high-throughput fractionation of natural products for drug discovery in spite of the solvent balancing requirement and the lower resolution of the shorter CCC columns.

  12. Multi-channel EEG-based sleep stage classification with joint collaborative representation and multiple kernel learning.

    Science.gov (United States)

    Shi, Jun; Liu, Xiao; Li, Yan; Zhang, Qi; Li, Yingjie; Ying, Shihui

    2015-10-30

    Electroencephalography (EEG) based sleep staging is commonly used in clinical routine. Feature extraction and representation plays a crucial role in EEG-based automatic classification of sleep stages. Sparse representation (SR) is a state-of-the-art unsupervised feature learning method suitable for EEG feature representation. Collaborative representation (CR) is an effective data coding method used as a classifier. Here we use CR as a data representation method to learn features from the EEG signal. A joint collaboration model is established to develop a multi-view learning algorithm, and generate joint CR (JCR) codes to fuse and represent multi-channel EEG signals. A two-stage multi-view learning-based sleep staging framework is then constructed, in which JCR and joint sparse representation (JSR) algorithms first fuse and learning the feature representation from multi-channel EEG signals, respectively. Multi-view JCR and JSR features are then integrated and sleep stages recognized by a multiple kernel extreme learning machine (MK-ELM) algorithm with grid search. The proposed two-stage multi-view learning algorithm achieves superior performance for sleep staging. With a K-means clustering based dictionary, the mean classification accuracy, sensitivity and specificity are 81.10 ± 0.15%, 71.42 ± 0.66% and 94.57 ± 0.07%, respectively; while with the dictionary learned using the submodular optimization method, they are 80.29 ± 0.22%, 71.26 ± 0.78% and 94.38 ± 0.10%, respectively. The two-stage multi-view learning based sleep staging framework outperforms all other classification methods compared in this work, while JCR is superior to JSR. The proposed multi-view learning framework has the potential for sleep staging based on multi-channel or multi-modality polysomnography signals. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Lipoatrofia semicircular: una revisión sistemática de la literatura Semicircular lipoatrophy: a sistematic review of the literature

    Directory of Open Access Journals (Sweden)

    Rafael Díaz Sarmiento

    2011-03-01

    Full Text Available Introducción: La lipoatrofia semicircular (LS es un trastorno benigno del tejido subcutáneo, de causa desconocida. Se caracteriza por depresiones semicirculares en la cara anterolateral de los muslos, unilaterales o bilaterales. Se relaciona con condiciones ambientales laborales, microtraumas repetidos y factores personales. Se plateó esta revisión sistemática de la literatura científica para caracterizar el conocimiento existente. Métodos: Revisión sistemática. Bases de datos: IBECS, IBSST, LILACS, IME, OSH-UPDATE, ISI-WOK, PubMed, CIS-DOC y Cochrane. Se incluyeron los artículos sobre lipoatrofia semicircular relacionada con condiciones de trabajo y medioambientales. Se utilizaron los niveles de evidencia científica del Scottish Intercollegiate Guidelines Network. Resultados: Se recuperaron 66 artículos. Solo 22 cumplieron los criterios de inclusión: Quince con nivel de evidencia 3 y 7 con nivel 4. Siete estudios de series de casos y ocho de casos únicos, sumaron 838 casos, informados entre 1982-2010. Los principales factores de riesgo para LS son: Microtraumas repetidos, humedad relativa baja y electricidad en los edificios modernos de oficinas. Las depresiones semicirculares ocurren en la cara anterolateral de muslos, sin alteración de la piel, en mujeres (85%, sin signos inflamatorios con histopatología inespecífica. La resonancia magnética, radiología y los anticuerpos antinucleares son negativos. El diagnóstico es clínico, apoyado con ecografía. El tratamiento psicológico y fisioterapia pueden ser útiles. Las medidas preventivas de mayor impacto son controlar los factores mencionados. Conclusiones: Existe insuficiente evidencia científica sobre las causas de LS. Es un trastorno prevalente, que genera alarma, relacionado con las condiciones de trabajo. Es necesario continuar la investigación sobre agentes causales.Introduction: The semicircular lipoatrophy (LS is a benign disorder of the subcutaneous tissue with

  14. ON SCALAR MESONS FROM THE COMBINED ANALYSIS OF MULTI-CHANNEL pi pi SCATTERING AND J/psi DECAYS

    Czech Academy of Sciences Publication Activity Database

    Surovtsev, Yu .S.; Bydžovský, Petr; Gutsche, T.; Lyubovitskij, V. E.

    2011-01-01

    Roč. 26, 3-4 (2011), s. 610-612 ISSN 0217-751X. [11th International Workshop on Meson Production , Properties and Interaction. Krakow, 10.06.2010-15.06.2010] R&D Projects: GA ČR GA202/08/0984 Institutional research plan: CEZ:AV0Z10480505 Keywords : Multi-channel pion-pion scattering * scalar-isoscalar resonances * multichannel analysis Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.053, year: 2011

  15. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...

  16. Joint image reconstruction method with correlative multi-channel prior for x-ray spectral computed tomography

    DEFF Research Database (Denmark)

    Kazantsev, Daniil; Jørgensen, Jakob Sauer; Andersen, Martin S

    2018-01-01

    peaks. The acquired energy-binned data, however, suffer from low signal-to-noise ratio, acquisition artifacts, and frequently angular undersampled conditions. New regularized iterative reconstruction methods have the potential to produce higher quality images and since energy channels are mutually...... to encourage joint smoothing directions. In particular, the method selects reference channels from which to propagate structure in an adaptive and stochastic way while preferring channels with a high data signal-to-noise ratio. The method is compared with current state-of-the-art multi-channel reconstruction...

  17. Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI

    Czech Academy of Sciences Publication Activity Database

    Kratochvíla, Jiří; Jiřík, Radovan; Bartoš, M.; Standara, M.; Starčuk jr., Zenon; Taxt, T.

    2016-01-01

    Roč. 75, č. 3 (2016), s. 1355-1365 ISSN 0740-3194 R&D Projects: GA ČR GAP102/12/2380; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : dynamic contrast-enhanced magnetic resonance imaging * multi-channel blind deconvolution * arterial input function * impulse residue function * renal cell carcinoma Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.924, year: 2016

  18. Multi-channel control circuit for real-time control of events in Aditya tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Edappala, Praveenlal, E-mail: praveen@ipr.res.in; Shah, Minsha; Rajpal, Rachana; Tanna, R.L.; Ghosh, Joydeep; Chattopadhyay, P.K.; Jha, R.

    2016-11-15

    Highlights: • Low cost microcontroller based control circuit. • The control hardware can be programmed/configured very easily for different applications. • Microcontroller programming is done in assembly language so that precise timing can be achieved with micro seconds resolution. • Successful implementation of this circuit in noisy tokamak environment. • Efficient noise and burst elimination. • Can be integrated in to the other subsystems. • Low cost solution for implementing feedback control in small and medium size tokamaks and other experiments requiring feedback control. - Abstract: Tokamak plasma is prone to many random events having potential for causing severe damages to the machine, such as disruptions, production and elimination of high-energy runaway electrons etc. These events can be mitigated by obtaining pre-cursor signal leading to these events and then taking proper measures just before their onset to avoid their happenings, like disruptions can be mitigated by massive gas injection or putting a bias voltage on an electrode placed inside the plasma, the runaways can be mitigated by gas injection and by applying specific magnetic fields. Hence for real time control of these events, the pre-cursors should be electronically recorded and the mitigation techniques should be initiated by sending triggers to their individual operational systems. To implement these methodologies of real-time controlling of events in Aditya Tokamak, a low cost multi-channel Micro-Controller based timing circuit is designed and developed in-house. This circuit first compares the precursor signals fed into it with the pre-set values and gives a trigger output whenever the signals overshoot the pre-set values. The circuit readies itself for operation along with start of the tokamak discharge and waits up to an initial pre-determined delay and then initiates a trigger at the time of overshooting of precursor signal. The circuit is fully integrated and assembled in

  19. Three-Dimensional Printed Prosthesis for Repair of Superior Canal Dehiscence.

    Science.gov (United States)

    Kozin, Elliott D; Remenschneider, Aaron K; Cheng, Song; Nakajima, Hideko Heidi; Lee, Daniel J

    2015-10-01

    Outcomes following repair of superior canal dehiscence (SCD) are variable, and surgery carries a risk of persistent or recurrent SCD symptoms, as well as a risk of hearing loss and vestibulopathy. Poor outcomes may occur from inadequate repair of the SCD or mechanical insult to the membranous labyrinth. Repair of SCD using a customized, fixed-length prosthesis may address current operative limitations and improve surgical outcomes. We aim to 3-dimensionally print customized prostheses to resurface or occlude bony SCD defects. Dehiscences were created along the arcuate eminence of superior semicircular canals in cadaveric temporal bones. Prostheses were designed and created using computed tomography and a 3-dimensional printer. The prostheses occupied the superior semicircular canal defect, reflected in postrepair computed tomography scans. This novel approach to SCD repair could have advantages over current techniques. Refinement of prosthesis design and materials will be important if this approach is translated into clinical use. © American Academy of Otolaryngology-Head and Neck Surgery Foundation 2015.

  20. Semicircular canal dehiscence: Frequency and distribution on temporal bone CT and its relationship with the clinical outcomes

    International Nuclear Information System (INIS)

    Elmali, Muzaffer; Polat, Ahmet Veysel; Kucuk, Harun; Atmaca, Sinan; Aksoy, Ahmet

    2013-01-01

    Purpose: In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. Materials and methods: Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of complaints such as vertigo, deafness, ear pain, fullness, and discharge between January 2008 and December 2011 were re-evaluated. Axial and oblique coronal reconstruction images of the temporal bone were made with a reconstruction thickness of 0.5 mm. Additionally, superior SC was evaluated in two perpendicular planes. Results: Out of 850 patients, 70 had completely normal temporal bone CT. Ninety-three patients had at least one SCD. In the temporal bone-based evaluation, 119 (26 bilateral, 67 unilateral) of 1700 temporal bones (7%) showed dehiscence. The SC-based evaluation revealed 125 SCD (2.5%) in 5100 SCs. The total number and rates of SCD were as follows: superior 103 (82.4%), posterior 13 (10.4%), and lateral nine (7.2%). Twenty of the 93 patients with SCD (21.5%) revealed no other findings on their temporal bone CTs. We determined a significant correlation between vestibular complaints, conductive hearing loss and SCD but there was no correlation between mixed, sensorineural hearing loss and SCD. Conclusion: We determined the frequency of SCD in 11% of patients and 7% of temporal bones. With regards to the distribution, the superior SC showed the highest dehiscence rate (82.4%). We found a significant correlation between vestibular symptoms, conductive hearing loss and SCD

  1. Semicircular canal dehiscence: Frequency and distribution on temporal bone CT and its relationship with the clinical outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Elmali, Muzaffer, E-mail: muzafel@yahoo.com.tr [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Polat, Ahmet Veysel, E-mail: veyselp@hotmail.com [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Kucuk, Harun, E-mail: hardrmd@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Atmaca, Sinan, E-mail: sinanatmaca@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Aksoy, Ahmet, E-mail: toxocara47@hotmail.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey)

    2013-10-01

    Purpose: In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. Materials and methods: Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of complaints such as vertigo, deafness, ear pain, fullness, and discharge between January 2008 and December 2011 were re-evaluated. Axial and oblique coronal reconstruction images of the temporal bone were made with a reconstruction thickness of 0.5 mm. Additionally, superior SC was evaluated in two perpendicular planes. Results: Out of 850 patients, 70 had completely normal temporal bone CT. Ninety-three patients had at least one SCD. In the temporal bone-based evaluation, 119 (26 bilateral, 67 unilateral) of 1700 temporal bones (7%) showed dehiscence. The SC-based evaluation revealed 125 SCD (2.5%) in 5100 SCs. The total number and rates of SCD were as follows: superior 103 (82.4%), posterior 13 (10.4%), and lateral nine (7.2%). Twenty of the 93 patients with SCD (21.5%) revealed no other findings on their temporal bone CTs. We determined a significant correlation between vestibular complaints, conductive hearing loss and SCD but there was no correlation between mixed, sensorineural hearing loss and SCD. Conclusion: We determined the frequency of SCD in 11% of patients and 7% of temporal bones. With regards to the distribution, the superior SC showed the highest dehiscence rate (82.4%). We found a significant correlation between vestibular symptoms, conductive hearing loss and SCD.

  2. Development of multi-channel high power rectangular RF window for LHCD system employing high temperature vacuum brazing technique

    International Nuclear Information System (INIS)

    Sharma, P K; Ambulkar, K K; Parmar, P R; Virani, C G; Thakur, A L; Joshi, L M; Nangru, S C

    2010-01-01

    A 3.7 GHz., 120 kW (pulsed), lower hybrid current drive (LHCD) system is employed to drive non-inductive plasma current in ADITYA tokamak. The rf power is coupled to the plasma through grill antenna and is placed in vacuum environment. A vacuum break between the pressurized transmission line and the grill antenna is achieved with the help of a multi (eight) channel rectangular RF vacuum window. The phasing between adjacent channels of 8-channel window (arranged in two rows) is important for launching lower hybrid waves and each channel should have independent vacuum window so that phase information is retained. The geometrical parameter of the grill antenna, like periodicity (9mm), channel dimensions (cross sectional dimension of 76mm x 7mm), etc. is to be maintained. These design constraint demanded a development of a multi channel rectangular RF vacuum window. To handle rf losses and thermal effects, high temperature vacuum brazing techniques is desired. Based on the above requirements we have successfully developed a multi channel rectangular rf vacuum window employing high temperature vacuum brazing technique. During the development process we could optimize the chemical processing parameters, brazing process parameters, jigs and fixtures for high temperature brazing and leak testing, etc. Finally the window is tested for low power rf performance using VNA. In this paper we would present the development of the said window in detail along with its mechanical, vacuum and rf performances.

  3. Development of multi-channel high power rectangular RF window for LHCD system employing high temperature vacuum brazing technique

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, P K; Ambulkar, K K; Parmar, P R; Virani, C G; Thakur, A L [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India); Joshi, L M; Nangru, S C, E-mail: pramod@ipr.res.i [Central Electronics Engineering Research Institute, Pilani, Rajasthan 333 031 (India)

    2010-02-01

    A 3.7 GHz., 120 kW (pulsed), lower hybrid current drive (LHCD) system is employed to drive non-inductive plasma current in ADITYA tokamak. The rf power is coupled to the plasma through grill antenna and is placed in vacuum environment. A vacuum break between the pressurized transmission line and the grill antenna is achieved with the help of a multi (eight) channel rectangular RF vacuum window. The phasing between adjacent channels of 8-channel window (arranged in two rows) is important for launching lower hybrid waves and each channel should have independent vacuum window so that phase information is retained. The geometrical parameter of the grill antenna, like periodicity (9mm), channel dimensions (cross sectional dimension of 76mm x 7mm), etc. is to be maintained. These design constraint demanded a development of a multi channel rectangular RF vacuum window. To handle rf losses and thermal effects, high temperature vacuum brazing techniques is desired. Based on the above requirements we have successfully developed a multi channel rectangular rf vacuum window employing high temperature vacuum brazing technique. During the development process we could optimize the chemical processing parameters, brazing process parameters, jigs and fixtures for high temperature brazing and leak testing, etc. Finally the window is tested for low power rf performance using VNA. In this paper we would present the development of the said window in detail along with its mechanical, vacuum and rf performances.

  4. Evaluation of K x-ray escape and crosstalk in CdTe detectors and multi-channel detectors

    International Nuclear Information System (INIS)

    Ohtsuchi, Tetsuro; Ohmori, Koichi; Tsutsui, Hiroshi; Baba, Sueki

    1995-01-01

    The simple structure of CdTe semiconductor detectors facilitates their downsizing, and their possible application to radiographic sensors has been studied. The escape of K X-rays from these detectors increases with reduction of their dimensions and affects the measurements of X- and gamma-ray spectra. K X-rays also produce crosstalk in multi-channel detectors with adjacent channels. Therefore, K X-rays which escape from the detector elements degrade both the precision of energy spectra and spatial resolution. The ratios of escape peak integrated counts to total photon counts for various sizes of CdTe single detectors were calculated for gamma rays using the Monte Carlo method. Also, escape and crosstalk ratios were simulated for the CdTe multi-channel detectors. The theoretical results were tested experimentally for 59.54-keV gamma rays from a 241 Am radioactive source. Results showed that escape ratios for single detectors were strongly dependent on element size and thickness. The escape and crosstalk ratios increased with closer channel pitch. The calculated results showed a good agreement with the experimental data. The calculations made it clear that K X-rays which escaped to neighboring channels induced crosstalk more frequently at smaller channel pitch in multichannel detectors. A radiation shielding grid which blocked incident photons between the boundary channels was also tested by experiment and by calculation. It was effective in reducing the probability of escape and crosstalk

  5. Multiplex multivariate recurrence network from multi-channel signals for revealing oil-water spatial flow behavior.

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Yang, Yu-Xuan; Cai, Qing

    2017-03-01

    The exploration of the spatial dynamical flow behaviors of oil-water flows has attracted increasing interests on account of its challenging complexity and great significance. We first technically design a double-layer distributed-sector conductance sensor and systematically carry out oil-water flow experiments to capture the spatial flow information. Based on the well-established recurrence network theory, we develop a novel multiplex multivariate recurrence network (MMRN) to fully and comprehensively fuse our double-layer multi-channel signals. Then we derive the projection networks from the inferred MMRNs and exploit the average clustering coefficient and the spectral radius to quantitatively characterize the nonlinear recurrent behaviors related to the distinct flow patterns. We find that these two network measures are very sensitive to the change of flow states and the distributions of network measures enable to uncover the spatial dynamical flow behaviors underlying different oil-water flow patterns. Our method paves the way for efficiently analyzing multi-channel signals from multi-layer sensor measurement system.

  6. Autonomous miniaturised device with USB interface for pulse height analysis and multi-channel scaling (TUKAN-8K-USB)

    International Nuclear Information System (INIS)

    Guzik, Z.; Borsuk, S.; Plominski, M.; Traczyk, K.

    2005-01-01

    We present autonomous a 8K-channel miniature device designed for spectroscopy or intensity vs. time measurements. The device (TUKAN-8K-USB) is based on the USB interface, and is contained in a screened separate box - it can be proved either directly from the USB port or from an external DC source (wall adapter of battery). The device may work in two independent operational modes: Multi-Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The crucial MCA component - Peak detect and Hold circuitry - is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with front edges down to 100 ns and has a differential linearity below 0.5% (full scale sliding scale averaging). Automatic stops on count in Region-Of-Interest (ROI) and on preset live or real time are implemented. The MCS works at medium speed counting rates (up to 8 MHz), with preset dwell time, number of channels and multi-sweep mode. Each these parameters can also be controlled externally. Digital interfacing is based on four used configurable logical I/O lines. A single CYCLONE EP1C3 Altera FPGA provides all control functions. The USB communication is based on FYDI FIFO controller. The analyzer is equipped with advanced, user-friendly software, which is subjected of another publication. )author)

  7. Harnessing mode-selective nonlinear optics for on-chip multi-channel all-optical signal processing

    Directory of Open Access Journals (Sweden)

    Ming Ma

    2016-11-01

    Full Text Available All-optical signal processing based on nonlinear optical effects allows for the realization of important functions in telecommunications including wavelength conversion, optical multiplexing/demultiplexing, Fourier transformation, and regeneration, amongst others, on ultrafast time scales to support high data rate transmission. In integrated photonic subsystems, the majority of all-optical signal processing systems demonstrated to date typically process only a single channel at a time or perform a single processing function, which imposes a serious limitation on the functionality of integrated solutions. Here, we demonstrate how nonlinear optical effects can be harnessed in a mode-selective manner to perform simultaneous multi-channel (two and multi-functional optical signal processing (i.e., regenerative wavelength conversion in an integrated silicon photonic device. This approach, which can be scaled to a higher number of channels, opens up a new degree of freedom for performing a broad range of multi-channel nonlinear optical signal processing functions using a single integrated photonic device.

  8. MULTIPLE SPINAL CANAL MENINGIOMAS

    Directory of Open Access Journals (Sweden)

    Nandigama Pratap Kumar

    2016-10-01

    Full Text Available BACKGROUND Meningiomas of the spinal canal are common tumours with the incidence of 25 percent of all spinal cord tumours. But multiple spinal canal meningiomas are rare in compare to solitary lesions and account for 2 to 3.5% of all spinal meningiomas. Most of the reported cases are both intra cranial and spinal. Exclusive involvement of the spinal canal by multiple meningiomas are very rare. We could find only sixteen cases in the literature to the best of our knowledge. Exclusive multiple spinal canal meningiomas occurring in the first two decades of life are seldom reported in the literature. We are presenting a case of multiple spinal canal meningiomas in a young patient of 17 years, who was earlier operated for single lesion. We analysed the literature, with illustration of our case. MATERIALS AND METHODS In September 2016, we performed a literature search for multiple spinal canal meningiomas involving exclusively the spinal canal with no limitation for language and publication date. The search was conducted through http://pubmed.com, a wellknown worldwide internet medical address. To the best of our knowledge, we could find only sixteen cases of multiple meningiomas exclusively confined to the spinal canal. Exclusive multiple spinal canal meningiomas occurring in the first two decades of life are seldom reported in the literature. We are presenting a case of multiple spinal canal meningiomas in a young patient of 17 years, who was earlier operated for solitary intradural extra medullary spinal canal meningioma at D4-D6 level, again presented with spastic quadriparesis of two years duration and MRI whole spine demonstrated multiple intradural extra medullary lesions, which were excised completely and the histopathological diagnosis was transitional meningioma. RESULTS Patient recovered from his weakness and sensory symptoms gradually and bladder and bowel symptoms improved gradually over a period of two to three weeks. CONCLUSION Multiple

  9. Design of canals

    CERN Document Server

    Swamee, P K

    2015-01-01

    The book presents firsthand material from the authors on design of hydraulic canals. The book discusses elements of design based on principles of hydraulic flow through canals. It covers optimization of design based on usage requirements and economic constraints. The book includes explicit design equations and design procedures along with design examples for varied cases. With its comprehensive coverage of the principles of hydraulic canal design, this book will prove useful to students, researchers, and practicing engineers. End-of-chapter pedagogical elements make it ideal for use in graduate courses on hydraulic structures offered by most civil engineering departments across the world.

  10. Monitoring of active layer dynamics at a permafrost site on Svalbard using multi-channel ground-penetrating radar

    Directory of Open Access Journals (Sweden)

    S. Westermann

    2010-11-01

    Full Text Available Multi-channel ground-penetrating radar is used to investigate the late-summer evolution of the thaw depth and the average soil water content of the thawed active layer at a high-arctic continuous permafrost site on Svalbard, Norway. Between mid of August and mid of September 2008, five surveys have been conducted in gravelly soil over transect lengths of 130 and 175 m each. The maximum thaw depths range from 1.6 m to 2.0 m, so that they are among the deepest thaw depths recorded in sediments on Svalbard so far. The thaw depths increase by approximately 0.2 m between mid of August and beginning of September and subsequently remain constant until mid of September. The thaw rates are approximately constant over the entire length of the transects within the measurement accuracy of about 5 to 10 cm. The average volumetric soil water content of the thawed soil varies between 0.18 and 0.27 along the investigated transects. While the measurements do not show significant changes in soil water content over the first four weeks of the study, strong precipitation causes an increase in average soil water content of up to 0.04 during the last week. These values are in good agreement with evapotranspiration and precipitation rates measured in the vicinity of the the study site. While we cannot provide conclusive reasons for the detected spatial variability of the thaw depth at the study site, our measurements show that thaw depth and average soil water content are not directly correlated.

    The study demonstrates the potential of multi-channel ground-penetrating radar for mapping thaw depth in permafrost areas. The novel non-invasive technique is particularly useful when the thaw depth exceeds 1.5 m, so that it is hardly accessible by manual probing. In addition, multi-channel ground-penetrating radar holds potential for mapping the latent heat content of the active layer and for estimating weekly to monthly averages of the ground heat flux during the

  11. Highly Efficient Multi Channel Packet Forwarding with Round Robin Intermittent Periodic Transmit for Multihop Wireless Backhaul Networks

    Science.gov (United States)

    Furukawa, Hiroshi

    2017-01-01

    Round Robin based Intermittent Periodic Transmit (RR-IPT) has been proposed which achieves highly efficient multi-hop relays in multi-hop wireless backhaul networks (MWBN) where relay nodes are 2-dimensionally deployed. This paper newly investigates multi-channel packet scheduling and forwarding scheme for RR-IPT. Downlink traffic is forwarded by RR-IPT via one of the channels, while uplink traffic and part of downlink are accommodated in the other channel. By comparing IPT and carrier sense multiple access with collision avoidance (CSMA/CA) for uplink/downlink packet forwarding channel, IPT is more effective in reducing packet loss rate whereas CSMA/CA is better in terms of system throughput and packet delay improvement. PMID:29137164

  12. Multi Channels PWM Controller for Thermoelectric Cooler Using a Programmable Logic Device and Lab-Windows CVI

    Directory of Open Access Journals (Sweden)

    Eli FLAXER

    2008-09-01

    Full Text Available We present a complete design of a multi channels PID controller for Thermoelectric Cooler (TEC using a pulse width modulation (PWM technique implemented by a dedicated programmable logic device (PLD programmed by VHDL. The PID control loop is implemented by software written by National Instrument Lab-Windows CVI. Due to the fact that the implementation is by a VHDL and PLD the design is modular, as a result, the circuit is very compact in size and very low cost as compared to any commercial product. In addition, since the control loop is implemented by software running on a personal computer (PC using a C language, it is easy to adjust the controller to various environmental conditions and for a width range of sensors like: a thermo couple (TC, thermistor, resistance temperature detectors (RTD etc. We demonstrate the performance of this circuit as a controller for a small incubator using thermistor as the temperature sensor.

  13. Leveraging multi-channel x-ray detector technology to improve quality metrics for industrial and security applications

    Science.gov (United States)

    Jimenez, Edward S.; Thompson, Kyle R.; Stohn, Adriana; Goodner, Ryan N.

    2017-09-01

    Sandia National Laboratories has recently developed the capability to acquire multi-channel radio- graphs for multiple research and development applications in industry and security. This capability allows for the acquisition of x-ray radiographs or sinogram data to be acquired at up to 300 keV with up to 128 channels per pixel. This work will investigate whether multiple quality metrics for computed tomography can actually benefit from binned projection data compared to traditionally acquired grayscale sinogram data. Features and metrics to be evaluated include the ability to dis- tinguish between two different materials with similar absorption properties, artifact reduction, and signal-to-noise for both raw data and reconstructed volumetric data. The impact of this technology to non-destructive evaluation, national security, and industry is wide-ranging and has to potential to improve upon many inspection methods such as dual-energy methods, material identification, object segmentation, and computer vision on radiographs.

  14. New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, Andrey V.; Egorov, Dmitry V. [LPP “EqualiZoom”, Astana, 010000 (Kazakhstan)

    2016-06-08

    This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

  15. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    International Nuclear Information System (INIS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Bosse, Harald; Tan, Jiubin

    2015-01-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications. (paper)

  16. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    Science.gov (United States)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  17. A Read-out and Data Acquisition System for the Outputs of Multi-channel Spectroscopy Amplifiers

    International Nuclear Information System (INIS)

    Kong Jie; Qian Yi; Su Hong; Dong Chengfu

    2009-01-01

    A read-out and data acquisition system for the outputs of multi-channel spectroscopy amplifiers is introduced briefly in this paper. The 16-channel gating integrator/multiplexer developed by us and PXI-DAQ card are used to construct this system. A virtual instrument system for displaying, indicating,measuring and recording of output waveform is accomplished by integrating the PC, hardware, software together flexibly based on the Lab Windows/CVI platform in our read-out and data acquisition system. In this system, an ADC can face the 16 outputs of 16-channel spectroscopy amplifiers, which can improve the system integration and reduce the cost of data acquisition system. The design provided a new way for building the read-out and data acquisition system using the normal modules and spectroscopy amplifiers. This system has been tested and demonstrated that it is intelligent, reliable, real-time and low cost. (authors)

  18. Development of hybrid micro circuit based multi-channel programmable HV supply for BARC-pelletron experimental facility

    International Nuclear Information System (INIS)

    Manna, A.; Thombare, S.; Moitra, S.; Kuswarkar, M.; Punna, M.; Nair, P.M.; Diwakar, M.P.; Pithawa, C.K.

    2013-01-01

    Electronics Division, BARC has developed a Multi channel programmable HV bias supply system for charge particle detector array for use in BARC-TIFR Pelletron-LINAC facility. The HV supplies are compact in size due to use of hybrid micro-circuits developed indigenously and are modular in construction to achieve versatility, scalability and serviceability. All programming operations and monitoring are performed remotely through PC over Ethernet. Each supply has a built-in over voltage, over current and thermal overload protections for safe operation and employs a Zero Voltage Switching (ZVS) technique to reduce thermal stress on the inverter switches. This article describes salient design aspects and performance of the HV supply system. (author)

  19. Benchmarking and qualification of the nufreq-npw code for best estimate prediction of multi-channel core stability margins

    International Nuclear Information System (INIS)

    Taleyarkhan, R.; McFarlane, A.F.; Lahey, R.T. Jr.; Podowski, M.Z.

    1988-01-01

    The work described in this paper is focused on the development, verification and benchmarking of the NUFREQ-NPW code at Westinghouse, USA for best estimate prediction of multi-channel core stability margins in US BWRs. Various models incorporated into NUFREQ-NPW are systematically compared against the Westinghouse channel stability analysis code MAZDA, which the Mathematical Model was developed in an entirely different manner. The NUFREQ-NPW code is extensively benchmarked against experimental stability data with and without nuclear reactivity feedback. Detailed comparisons are next performed against nuclear-coupled core stability data. A physically based algorithm is developed to correct for the effect of flow development on subcooled boiling. Use of this algorithm (to be described in the full paper) captures the peak magnitude as well as the resonance frequency with good accuracy

  20. Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Cho, Chan Hee; Cho, Hyun Joon

    2009-01-01

    Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needs for development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

  1. Superior Canal Dehiscence Syndrome Affecting 3 Families.

    Science.gov (United States)

    Heidenreich, Katherine D; Kileny, Paul R; Ahmed, Sameer; El-Kashlan, Hussam K; Melendez, Tori L; Basura, Gregory J; Lesperance, Marci M

    2017-07-01

    Superior canal dehiscence syndrome (SCDS) is an increasingly recognized cause of hearing loss and vestibular symptoms, but the etiology of this condition remains unknown. To describe 7 cases of SCDS across 3 families. This retrospective case series included 7 patients from 3 different families treated at a neurotology clinic at a tertiary academic medical center from 2010 to 2014. Patients were referred by other otolaryngologists or were self-referred. Each patient demonstrated unilateral or bilateral SCDS or near dehiscence. Clinical evaluation involved body mass index calculation, audiometry, cervical vestibular evoked myogenic potential testing, electrocochleography, and multiplanar computed tomographic (CT) scan of the temporal bones. Zygosity testing was performed on twin siblings. The diagnosis of SCDS was made if bone was absent over the superior semicircular canal on 2 consecutive CT images, in addition to 1 physiologic sign consistent with labyrinthine dehiscence. Near dehiscence was defined as absent bone on only 1 CT image but with symptoms and at least 1 physiologic sign of labyrinthine dehiscence. A total of 7 patients (5 female and 2 male; age range, 8-49 years) from 3 families underwent evaluation. Family A consisted of 3 adult first-degree relatives, of whom 2 were diagnosed with SCDS and 1 with near dehiscence. Family B included a mother and her child, both of whom were diagnosed with unilateral SCDS. Family C consisted of adult monozygotic twins, each of whom was diagnosed with unilateral SCDS. For all cases, dehiscence was located at the arcuate eminence. Obesity alone did not explain the occurrence of SCDS because 5 of the 7 cases had a body mass index (calculated as weight in kilograms divided by height in meters squared) less than 30.0. Superior canal dehiscence syndrome is a rare, often unrecognized condition. This report of 3 multiplex families with SCDS provides evidence in support of a potential genetic contribution to the etiology

  2. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  3. The dynamic time-over-threshold method for multi-channel APD based gamma-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Orita, T., E-mail: orita.tadashi@jaea.go.jp [Japan Atomic Energy Agency, Fukushima (Japan); Shimazoe, K.; Takahashi, H. [Department of Nuclear Management and Engineering, The University of Tokyo, Bunkyō (Japan)

    2015-03-01

    t– Recent advances in manufacturing technology have enabled the use of multi-channel pixelated detectors in gamma-ray imaging applications. When obtaining gamma-ray measurements, it is important to obtain pulse height information in order to avoid unnecessary events such as scattering. However, as the number of channels increases, more electronics are needed to process each channel's signal, and the corresponding increases in circuit size and power consumption can result in practical problems. The time-over-threshold (ToT) method, which has recently become popular in the medical field, is a signal processing technique that can effectively avoid such problems. However, ToT suffers from poor linearity and its dynamic range is limited. We therefore propose a new ToT technique called the dynamic time-over-threshold (dToT) method [4]. A new signal processing system using dToT and CR-RC shaping demonstrated much better linearity than that of a conventional ToT. Using a test circuit with a new Gd{sub 3}Al{sub 2}Ga{sub 3}O{sub 12} (GAGG) scintillator and an avalanche photodiode, the pulse height spectra of {sup 137}Cs and {sup 22}Na sources were measured with high linearity. Based on these results, we designed a new application-specific integrated circuit (ASIC) for this multi-channel dToT system, measured the spectra of a {sup 22}Na source, and investigated the linearity of the system.

  4. TUKAN—An 8K Pulse Height Analyzer and Multi-Channel Scaler With a PCI or a USB Interface

    Science.gov (United States)

    Guzik, Z.; Borsuk, S.; Traczyk, K.; Plominski, M.

    2006-02-01

    In this paper we present two types of 8K-channel analyzers designed for spectroscopy and intensity versus time measurements. The first type (Tukan-8K-PCI) incorporates a PCI interface and is designed to be plugged into a PCI slot of a normal PC. The second type (Tukan-8K-USB) incorporates a USB interface. It is mounted in a separate screened box and can be powered either directly from the USB port or from an external dc source (wall adapter or battery). Each type of device may operate in either of two independent operational modes: Multi Channel Analysis (MCA) and Multi-Channel Scaling (MCS). The most crucial component for the MCA mode-the Peak Detect and Hold circuit-is featuring a novel architecture based on a diamond transistor. Its analog stage can accept analog pulses with rise times as short as 100 ns and has a differential linearity below 1% with sliding scale averaging over the full scale. The functionality includes automatic stop on a programmable count in the Region-Of-Interest (ROI) and on preset live- or real time. The MCS mode works at medium counting rates of up to 8 MHz. The dwell time, the number of channels and single or multi-sweep mode may be preset. Each of these parameters can also be controlled externally via four user configurable logical I/O lines. A single Altera FLEX 10KE30 FPGA provides all control functions and incorporates PCI interface. The USB interface is based on FTDI FIFO controller. Advanced and user-friendly software has been developed for the analyzer

  5. User manual for semi-circular compact range reflector code: Version 2

    Science.gov (United States)

    Gupta, Inder J.; Burnside, Walter D.

    1987-01-01

    A computer code has been developed at the Ohio State University ElectroScience Laboratory to analyze a semi-circular paraboloidal reflector with or without a rolled edge at the top and a skirt at the bottom. The code can be used to compute the total near field of the reflector or its individual components at a given distance from the center of the paraboloid. The code computes the fields along a radial, horizontal, vertical or axial cut at that distance. Thus, it is very effective in computing the size of the sweet spot for a semi-circular compact range reflector. This report describes the operation of the code. Various input and output statements are explained. Some results obtained using the computer code are presented to illustrate the code's capability as well as being samples of input/output sets.

  6. Adaptive multi-channel downlink assignment for overloaded spectrum-shared multi-antenna overlaid cellular networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2012-10-19

    Overlaid cellular technology has been considered as a promising candidate to enhance the capacity and extend the coverage of cellular networks, particularly indoors. The deployment of small cells (e.g. femtocells and/or picocells) in an overlaid setup is expected to reduce the operational power and to function satisfactorily with the existing cellular architecture. Among the possible deployments of small-cell access points is to manage many of them to serve specific spatial locations, while reusing the available spectrum universally. This contribution considers the aforementioned scenario with the objective to serve as many active users as possible when the available downlink spectrum is overloaded. The case study is motivated by the importance of realizing universal resource sharing in overlaid networks, while reducing the load of distributing available resources, satisfying downlink multi-channel assignment, controlling the aggregate level of interference, and maintaining desired design/operation requirements. These objectives need to be achieved in distributed manner in each spatial space with as low processing load as possible when the feedback links are capacity-limited, multiple small-cell access points can be shared, and data exchange between access points can not be coordinated. This contribution is summarized as follows. An adaptive downlink multi-channel assignment scheme when multiple co-channel and shared small-cell access points are allocated to serve active users is proposed. It is assumed that the deployed access points employ isotropic antenna arrays of arbitrary sizes, operate using the open-access strategy, and transmit on shared physical channels simultaneously. Moreover, each active user can be served by a single transmit channel per each access point at a time, and can sense the concurrent interference level associated with each transmit antenna channel non-coherently. The proposed scheme aims to identify a suitable subset of transmit channels

  7. Development and field example of multi channel surface wave data acquisition and processing system (SWS-1); Multi channel hyomenha data shutoku shori system (SWS-1) no kaihatsu to jikkenrei

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Huashui Institute of Geophysical Exploration, (China); Wang, Z [Bureauof Engineering MGMR, (China); Zhang, Z [STG Corp., (China); Tanaka, Y

    1996-05-01

    A report is given here about the use of a newly-developed multi-channel surface wave data acquisition and processing system different from the conventional surface wave exploration device. This system enables the on-site pickup of a dispersion curve out of the multi-component surface wave data and, in the analysis of underground structure, performs the forward modeling and inversion. The system, furthermore, acquires and analyzes the data obtained from reflection earthquake exploration and constant microtremor observation. During a survey conducted along the highway from Port Ren-un to Xuzhou, China, estimation of the basement boundary was made by use of dynamite, and what was obtained agreed with the result of boring though with an error of 3m. In addition, this system could probe levels deeper than 100m using the instantaneous Rayleigh wave exploration method. This system and the conventional surface exploration device were compared in a soft ground in Fukui Prefecture, the former using a 10kg hammer and the latter using a 350kg exciter, when it was verified that the results produced by both techniques excellently agree with the geologic columnar section and changes in the N-value. 4 refs., 4 figs.

  8. Continuous Adductor Canal Blocks

    DEFF Research Database (Denmark)

    Monahan, Amanda M; Sztain, Jacklynn F; Khatibi, Bahareh

    2016-01-01

    on cutaneous knee sensation in volunteers. METHODS: Bilateral adductor canal catheters were inserted in 24 volunteers followed by ropivacaine 0.2% administration for 8 hours. One limb of each subject was assigned randomly to a continuous infusion (8 mL/h) or automated hourly boluses (8 m...

  9. CANAL user's manual

    International Nuclear Information System (INIS)

    Faya, A.; Wolf, L.; Todreas, N.

    1979-11-01

    CANAL is a subchannel computer program for the steady-state and transient thermal hydraulic analysis of BWR fuel rod bundles. The purpose of this manual is to introduce the user into the mechanism of running the code by providing information about the input data and options

  10. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud

    2013-06-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  11. Joint image reconstruction method with correlative multi-channel prior for x-ray spectral computed tomography

    Science.gov (United States)

    Kazantsev, Daniil; Jørgensen, Jakob S.; Andersen, Martin S.; Lionheart, William R. B.; Lee, Peter D.; Withers, Philip J.

    2018-06-01

    Rapid developments in photon-counting and energy-discriminating detectors have the potential to provide an additional spectral dimension to conventional x-ray grayscale imaging. Reconstructed spectroscopic tomographic data can be used to distinguish individual materials by characteristic absorption peaks. The acquired energy-binned data, however, suffer from low signal-to-noise ratio, acquisition artifacts, and frequently angular undersampled conditions. New regularized iterative reconstruction methods have the potential to produce higher quality images and since energy channels are mutually correlated it can be advantageous to exploit this additional knowledge. In this paper, we propose a novel method which jointly reconstructs all energy channels while imposing a strong structural correlation. The core of the proposed algorithm is to employ a variational framework of parallel level sets to encourage joint smoothing directions. In particular, the method selects reference channels from which to propagate structure in an adaptive and stochastic way while preferring channels with a high data signal-to-noise ratio. The method is compared with current state-of-the-art multi-channel reconstruction techniques including channel-wise total variation and correlative total nuclear variation regularization. Realistic simulation experiments demonstrate the performance improvements achievable by using correlative regularization methods.

  12. Vehicular Networking Enhancement And Multi-Channel Routing Optimization, Based on Multi-Objective Metric and Minimum Spanning Tree

    Directory of Open Access Journals (Sweden)

    Peppino Fazio

    2013-01-01

    Full Text Available Vehicular Ad hoc NETworks (VANETs represent a particular mobile technology that permits the communication among vehicles, offering security and comfort. Nowadays, distributed mobile wireless computing is becoming a very important communications paradigm, due to its flexibility to adapt to different mobile applications. VANETs are a practical example of data exchanging among real mobile nodes. To enable communications within an ad-hoc network, characterized by continuous node movements, routing protocols are needed to react to frequent changes in network topology. In this paper, the attention is focused mainly on the network layer of VANETs, proposing a novel approach to reduce the interference level during mobile transmission, based on the multi-channel nature of IEEE 802.11p (1609.4 standard. In this work a new routing protocol based on Distance Vector algorithm is presented to reduce the delay end to end and to increase packet delivery ratio (PDR and throughput in VANETs. A new metric is also proposed, based on the maximization of the average Signal-to-Interference Ratio (SIR level and the link duration probability between two VANET nodes. In order to relieve the effects of the co-channel interference perceived by mobile nodes, transmission channels are switched on a basis of a periodical SIR evaluation. A Network Simulator has been used for implementing and testing the proposed idea.

  13. Reduced-complexity adaptive multi-channel assignment for shared access points in over-loaded small-cell networks

    KAUST Repository

    Radaydeh, Redha Mahmoud; Qaraqe, Khalid A.; Alouini, Mohamed-Slim

    2013-01-01

    This paper proposes a reduced-complexity downlink multi-channel assignment scheme when feedback links are capacity-limited. The system model treats the case when multiple access points are allocated to serve scheduled users in over-loaded (i.e. dense) pico/femtocell networks. It assumes that the deployed access points can be shared simultaneously and employ isotropic antenna arrays of arbitrary sizes. Moreover, they transmit their data on a common physical channel and can not coordinate their transmissions. On the other hand, each scheduled user can be served by single transmit channel from each active access point at a time, and it lacks coordination with concurrent active users. The scheme operates according to the occupancy of available transmit channels, wherein extensively occupied access points are avoided adaptively, while reducing the load of processing. The operation is linked to a target performance via controlling the observed aggregate interference from the projected set of serving points. Through the analysis, results for the scheduled user outage performance, and the average number of active access points are presented. Numerical and simulations studies clarify the gains of the proposed scheme for different operating conditions. © 2013 IEEE.

  14. New geological interpretation of multi-channel seismic profiles from the Pacific Margin of the Antarctic Peninsula

    Directory of Open Access Journals (Sweden)

    Okoń Jan

    2016-06-01

    Full Text Available The Polish Geophysical Expedition to West Antarctica in 1979–1980 was carried out by the Institute of Geophysics, Polish Academy of Sciences. Beside deep seismic soundings, 12 multi-channel seismic profiles, with a total length of ca 1000 km have been recorded north and east of the South Shetland Islands and in the Bransfield Strait, but they have never before been completely interpreted and published. All profiles have been processed with modern processing flow including time migration. Profiles crossing the South Shetland Trench revealed distinct reflector inside continental slope, which has been interpreted as border between buried accretionary prism and overlying slope sediments of glacial-marine origin. Profiles in the Bransfield Strait show traces of the Last Glacial Maximum (LGM in the form of glacial foreground valleys, with some of them used as weak spots for young age volcanic intrusions. This paper is the first comprehensive geological interpretation of collected dataset and differences between results from other expeditions are discussed.

  15. BDNF gene delivery within and beyond templated agarose multi-channel guidance scaffolds enhances peripheral nerve regeneration

    Science.gov (United States)

    Gao, Mingyong; Lu, Paul; Lynam, Dan; Bednark, Bridget; Campana, W. Marie; Sakamoto, Jeff; Tuszynski, Mark

    2016-12-01

    Objective. We combined implantation of multi-channel templated agarose scaffolds with growth factor gene delivery to examine whether this combinatorial treatment can enhance peripheral axonal regeneration through long sciatic nerve gaps. Approach. 15 mm long scaffolds were templated into highly organized, strictly linear channels, mimicking the linear organization of natural nerves into fascicles of related function. Scaffolds were filled with syngeneic bone marrow stromal cells (MSCs) secreting the growth factor brain derived neurotrophic factor (BDNF), and lentiviral vectors expressing BDNF were injected into the sciatic nerve segment distal to the scaffold implantation site. Main results. Twelve weeks after injury, scaffolds supported highly linear regeneration of host axons across the 15 mm lesion gap. The incorporation of BDNF-secreting cells into scaffolds significantly increased axonal regeneration, and additional injection of viral vectors expressing BDNF into the distal segment of the transected nerve significantly enhanced axonal regeneration beyond the lesion. Significance. Combinatorial treatment with multichannel bioengineered scaffolds and distal growth factor delivery significantly improves peripheral nerve repair, rivaling the gold standard of autografts.

  16. Spectrum-efficient multi-channel design for coexisting IEEE 802.15.4 networks: A stochastic geometry approach

    KAUST Repository

    Elsawy, Hesham

    2014-07-01

    For networks with random topologies (e.g., wireless ad-hoc and sensor networks) and dynamically varying channel gains, choosing the long term operating parameters that optimize the network performance metrics is very challenging. In this paper, we use stochastic geometry analysis to develop a novel framework to design spectrum-efficient multi-channel random wireless networks based on the IEEE 802.15.4 standard. The proposed framework maximizes both spatial and time domain frequency utilization under channel gain uncertainties to minimize the number of frequency channels required to accommodate a certain population of coexisting IEEE 802.15.4 networks. The performance metrics are the outage probability and the self admission failure probability. We relax the single channel assumption that has been used traditionally in the stochastic geometry analysis. We show that the intensity of the admitted networks does not increase linearly with the number of channels and the rate of increase of the intensity of the admitted networks decreases with the number of channels. By using graph theory, we obtain the minimum required number of channels to accommodate a certain intensity of coexisting networks under a self admission failure probability constraint. To this end, we design a superframe structure for the coexisting IEEE 802.15.4 networks and a method for time-domain interference alignment. © 2002-2012 IEEE.

  17. Ab initio R-matrix/Multi-channel Quantum Defect Theory applied to Molecular Core Excitation and Ionization

    International Nuclear Information System (INIS)

    Hiyama, M.; Kosugi, N.

    2004-01-01

    Full text: Ab initio R-matrix/MQDT approach, which is a combination of ab initio R-matrix techniques and the multi channel quantum defect theory (MQDT), has recently been developed by one of the present authors (MH) and Child, to successfully obtain the potential energy curves of Rydberg states converging to not only the lowest but also the higher ionized states. This approach is also applied to estimate the valence state interaction with Rydberg and continuum (ionization) channels. Very recently we have made an original ab initio polyatomic R-matrix/MQDT program package, GSCF4R based on Gaussian type basis functions for the bound and continuum states, to extensively study molecular excitation and ionization in the X-ray region as well as in the VUV region. We are going to report the results for core excitation and ionization of diatomic molecules such as NO and O 2 to show that the R-matrix/MQDT method is indispensable to describe the core-to-Rydberg states with the higher quantum number and the continuum states. These results lead us to the conclusion that the close-coupling approximation augmented with the correlation term within the R-matrix/MQDT formalism is powerful to calculate the Rydberg-valence mixing and the interchannel coupling between several core-ionized states

  18. 'Too much, too late': mixed methods multi-channel video recording study of computerized decision support systems and GP prescribing.

    Science.gov (United States)

    Hayward, James; Thomson, Fionagh; Milne, Heather; Buckingham, Susan; Sheikh, Aziz; Fernando, Bernard; Cresswell, Kathrin; Williams, Robin; Pinnock, Hilary

    2013-06-01

    Computerized decision support systems (CDSS) are commonly deployed to support prescribing, although over-riding of alerts by prescribers remains a concern. We aimed to understand how general practitioners (GPs) interact with prescribing CDSS in order to inform deliberation on how better to support prescribing decisions in primary care. Quantitative and qualitative analysis of interactions between GPs, patients, and computer systems using multi-channel video recordings of 112 primary care consultations with eight GPs in three UK practices. 132 prescriptions were issued in the course of 73 of the consultations, of which 81 (61%) attracted at least one alert. Of the total of 117 alerts, only three resulted in the GP checking, but not altering, the prescription. CDSS provided information and safety alerts at the point of generating a prescription. This was 'too much, too late' as the majority of the 'work' of prescribing occurred prior to using the computer. By the time an alert appeared, the GP had formulated the problem(s), potentially spent several minutes considering, explaining, negotiating, and reaching agreement with the patient about the proposed treatment, and had possibly given instructions and printed an information leaflet. CDSS alerts do not coincide with the prescribing workflow throughout the whole GP consultation. Current systems interrupt to correct decisions that have already been taken, rather than assisting formulation of the management plan. CDSS are likely to be more acceptable and effective if the prescribing support is provided much earlier in the process of generating a prescription.

  19. Research on multi - channel interactive virtual assembly system for power equipment under the “VR+” era

    Science.gov (United States)

    Ren, Yilong; Duan, Xitong; Wu, Lei; He, Jin; Xu, Wu

    2017-06-01

    With the development of the “VR+” era, the traditional virtual assembly system of power equipment has been unable to satisfy our growing needs. In this paper, based on the analysis of the traditional virtual assembly system of electric power equipment and the application of VR technology in the virtual assembly system of electric power equipment in our country, this paper puts forward the scheme of establishing the virtual assembly system of power equipment: At first, we should obtain the information of power equipment, then we should using OpenGL and multi texture technology to build 3D solid graphics library. After the completion of three-dimensional modeling, we can use the dynamic link library DLL package three-dimensional solid graphics generation program to realize the modularization of power equipment model library and power equipment model library generated hidden algorithm. After the establishment of 3D power equipment model database, we set up the virtual assembly system of 3D power equipment to separate the assembly operation of the power equipment from the space. At the same time, aiming at the deficiency of the traditional gesture recognition algorithm, we propose a gesture recognition algorithm based on improved PSO algorithm for BP neural network data glove. Finally, the virtual assembly system of power equipment can really achieve multi-channel interaction function.

  20. A Multi-Channel Opto-Electronic Sensor to Accurately Monitor Heart Rate against Motion Artefact during Exercise

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-10-01

    Full Text Available This study presents the use of a multi-channel opto-electronic sensor (OEPS to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA, and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05; a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001; the bias of BAA 0.85 bpm, the standard deviation (SD 9.20 bpm, and the limits of agreement (LOA from −17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001; the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from −15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  1. Sum Utilization of Spectrum with Spectrum Handoff and Imperfect Sensing in Interweave Multi-Channel Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    Waqas Khalid

    2018-05-01

    Full Text Available Fifth-generation (5G heterogeneous network deployment poses new challenges for 5G-based cognitive radio networks (5G-CRNs as the primary user (PU is required to be more active because of the small cells, random user arrival, and spectrum handoff. Interweave CRNs (I-CRNs improve spectrum utilization by allowing opportunistic spectrum access (OSA for secondary users (SUs. The sum utilization of spectrum, i.e., joint utilization of spectrum by the SU and PU, depends on the spatial and temporal variations of PU activities, sensing outcomes, transmitting conditions, and spectrum handoff. In this study, we formulate and analyze the sum utilization of spectrum with different sets of channels under different PU and SU co-existing network topologies. We consider realistic multi-channel scenarios for the SU, with each channel licensed to a PU. The SU, aided by spectrum handoff, is authorized to utilize the channels on the basis of sensing outcomes and PU interruptions. The numerical evaluation of the proposed work is presented under different network and sensing parameters. Moreover, the sum utilization gain is investigated to analyze the sensitivities of different sensing parameters. It is demonstrated that different sets of channels, PU activities, and sensing outcomes have a significant impact on the sum utilization of spectrum associated with a specific network topology.

  2. Evaluation of the potential of soil remediation by direct multi-channel pulsed corona discharge in soil.

    Science.gov (United States)

    Wang, Tie Cheng; Qu, Guangzhou; Li, Jie; Liang, Dongli

    2014-01-15

    A novel approach, named multi-channel pulsed corona discharge in soil, was developed for remediating organic pollutants contaminated soil, with p-nitrophenol (PNP) as the model pollutant. The feasibility of PNP degradation in soil was explored by evaluating effects of pulse discharge voltage, air flow rate and soil moisture on PNP degradation. Based on roles of chemically active species and evolution of degradation intermediates, PNP degradation processes were discussed. Experimental results showed that about 89.4% of PNP was smoothly degraded within 60min of discharge treatment at pulse discharge voltage 27kV, soil moisture 5% and air flow rate 0.8Lmin(-1), and the degradation process fitted the first-order kinetic model. Increasing pulse discharge voltage was found to be favorable for PNP degradation, but not for energy yield. There existed appropriate air flow rate and soil moisture for obtaining gratifying PNP degradation efficacy. Roles of radical scavenger and measurement of active species suggested that ozone, H2O2, and OH radicals played very important roles in PNP degradation. CN bond in PNP molecule was cleaved, and the main intermediate products such as hydroquinone, benzoquinone, catechol, phenol, acetic acid, formic acid, oxalic acid, NO2(-) and NO3(-) were identified. Possible pathway of PNP degradation in soil in such a system was proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Benchmarking and qualification of the NUFREQ-NPW code for best estimate prediction of multi-channel core stability margins

    International Nuclear Information System (INIS)

    Taleyarkhan, R.; Lahey, R.T. Jr.; McFarlane, A.F.; Podowski, M.Z.

    1988-01-01

    The NUFREQ-NPW code was modified and set up at Westinghouse, USA for mixed fuel type multi-channel core-wide stability analysis. The resulting code, NUFREQ-NPW, allows for variable axial power profiles between channel groups and can handle mixed fuel types. Various models incorporated into NUFREQ-NPW were systematically compared against the Westinghouse channel stability analysis code MAZDA-NF, for which the mathematical model was developed, in an entirely different manner. Excellent agreement was obtained which verified the thermal-hydraulic modeling and coding aspects. Detailed comparisons were also performed against nuclear-coupled reactor core stability data. All thirteen Peach Bottom-2 EOC-2/3 low flow stability tests were simulated. A key aspect for code qualification involved the development of a physically based empirical algorithm to correct for the effect of core inlet flow development on subcooled boiling. Various other modeling assumptions were tested and sensitivity studies performed. Good agreement was obtained between NUFREQ-NPW predictions and data. Moreover, predictions were generally on the conservative side. The results of detailed direct comparisons with experimental data using the NUFREQ-NPW code; have demonstrated that BWR core stability margins are conservatively predicted, and all data trends are captured with good accuracy. The methodology is thus suitable for BWR design and licensing purposes. 11 refs., 12 figs., 2 tabs

  4. Leveraging accelerated testing of LED drivers to model the reliability of two-stage and multi-channel drivers

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Perkins, Curtis; Smith, Aaron; Clark, Terry; Mills, Karmann

    2017-05-30

    The next wave of LED lighting technology is likely to be tunable white lighting (TWL) devices which can adjust the colour of the emitted light between warm white (~ 2700 K) and cool white (~ 6500 K). This type of lighting system uses LED assemblies of two or more colours each controlled by separate driver channels that independently adjust the current levels to achieve the desired lighting colour. Drivers used in TWL devices are inherently more complex than those found in simple SSL devices, due to the number of electrical components in the driver required to achieve this level of control. The reliability of such lighting systems can only be studied using accelerated stress tests (AST) that accelerate the aging process to time frames that can be accommodated in laboratory testing. This paper describes AST methods and findings developed from AST data that provide insights into the lifetime of the main components of one-channel and multi-channel LED devices. The use of AST protocols to confirm product reliability is necessary to ensure that the technology can meet the performance and lifetime requirements of the intended application.

  5. Curved canals: Ancestral files revisited

    Directory of Open Access Journals (Sweden)

    Jain Nidhi

    2008-01-01

    Full Text Available The aim of this article is to provide an insight into different techniques of cleaning and shaping of curved root canals with hand instruments. Although a plethora of root canal instruments like ProFile, ProTaper, LightSpeed ® etc dominate the current scenario, the inexpensive conventional root canal hand files such as K-files and flexible files can be used to get optimum results when handled meticulously. Special emphasis has been put on the modifications in biomechanical canal preparation in a variety of curved canal cases. This article compiles a series of clinical cases of root canals with curvatures in the middle and apical third and with S-shaped curvatures that were successfully completed by employing only conventional root canal hand instruments.

  6. Semicircular Horizontal Approach in Breast Reduction: Clinical Experience in 38 Cases

    Directory of Open Access Journals (Sweden)

    Hee Su Shin

    2015-07-01

    Full Text Available BackgroundVarious techniques are used for performing breast reduction. Wise-pattern and vertical scar techniques are the most commonly employed approaches. However, a vertical scar in the mid-lower breast is prominent and aesthetically less pleasant. In contrast, a semicircular horizontal approach does not leave a vertical scar in the mid breast and transverse scars can be hidden in the inframammary fold. In this paper, we describe the experiences and results of semicircular horizontal breast reductions performed by a single surgeon.MethodsBetween September 1996 and October 2013, our senior author used this technique in 38 cases in the US and at our institution. We used a superiorly based semicircular incision, where the upper skin paddle was pulled down to the inframammary fold with the nipple-areola complex pulled through the keyhole.ResultsThe average total reduction per breast was 584 g, ranging from 286 to 794 g. The inferior longitudinal pedicle was used in all the cases. The average reduction of the distance from the sternal notch to the nipple was 13 cm (range, 11-15 cm. The mean decrease in the bra cup size was 1.7 cup sizes (range, a decrease of 1 to 3. We obtained very satisfactory results with a less noticeable scar, no complication such as necrosis of the nipple or the skin flap, wound infection, aseptic necrosis of the breast tissue, or wound dehiscence. One patient had a small hematoma that resolved spontaneously.ConclusionsThis technique is straightforward and easy to learn, and offers a safe, effective, and predictable way for treating mammary hypertrophy.

  7. A new Implementation of the multi-channel analysis in the dosimetry through radiochromic films; Una nueva implementacion del analisis multicanal en la dosimetria mediante peliculas radiocromicas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Rodriguez, C.; Martin Martin, G.; Bermudez Luna, R.; Lopez Fernandez, A.; Torres Olombrada, M. V. de; Garcia Canibano, T.; Caballero Guerra, P.

    2013-07-01

    The objectives of this study are to implement multi-channel analysis algorithm using open source tools, extend the application of the same to a scanner other than the supported by Micke, generate maps of dose absorbed in compatible format with the PTW Verisoft quality control program and to quantify the improvement in the results of the gamma index as to what would be obtained by applying a conventional single-channel analysis. (Author)

  8. Multi-Channel Electroencephalogram (EEG) Signal Acquisition and its Effective Channel selection with De-noising Using AWICA for Biometric System

    OpenAIRE

    B.Sabarigiri; D.Suganyadevi

    2014-01-01

    the embedding of low cost electroencephalogram (EEG) sensors in wireless headsets gives improved authentication based on their brain wave signals has become a practical opportunity. In this paper signal acquisition along with effective multi-channel selection from a specific area of the brain and denoising using AWICA methods are proposed for EEG based personal identification. At this point, to develop identification system the steps are as follows. (i) the high-quality device with the least ...

  9. Multi-channel and porous SiO@N-doped C rods as anodes for high-performance lithium-ion batteries

    Science.gov (United States)

    Huang, Xiao; Li, Mingqi

    2018-05-01

    To improve the cycling stability and rate capability of SiO electrodes, multi-channel and porous SiO@N-doped C (mp-SiO@N-doped C) rods are fabricated by the combination of electrospinning and heat treatment with the assistance of poly(methyl methacrylate) (PMMA). During annealing, in-situ PMMA degradation and gasification lead to the formation of multi-channel structure and more pores. As anodes for lithium ion batteries, the mp-SiO@N-doped C rods exhibit excellent cycling stability. At a current density of 400 mA g-1, a discharge capacity of 806 mAh g-1 can be kept after 250 cycles, the retention of which is over than 100% versus the initial reversible capacity. Compared with the SiO@N-doped C rods synthesized without the help of PMMA, the mp-SiO@N-doped C rods exhibit more excellent rate capability. The excellent electrochemical performance is attributed to the special structure of the mp-SiO@N-doped C rods. In addition to the conductivity improved by carbon fibers, the multi-channel and porous structures not only make ions/electrons transfer and electrolyte diffusion easier, but also contribute to the structural stability of the electrodes.

  10. Exploring the complementarity of THz pulse imaging and DCE-MRIs: Toward a unified multi-channel classification and a deep learning framework.

    Science.gov (United States)

    Yin, X-X; Zhang, Y; Cao, J; Wu, J-L; Hadjiloucas, S

    2016-12-01

    We provide a comprehensive account of recent advances in biomedical image analysis and classification from two complementary imaging modalities: terahertz (THz) pulse imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The work aims to highlight underlining commonalities in both data structures so that a common multi-channel data fusion framework can be developed. Signal pre-processing in both datasets is discussed briefly taking into consideration advances in multi-resolution analysis and model based fractional order calculus system identification. Developments in statistical signal processing using principal component and independent component analysis are also considered. These algorithms have been developed independently by the THz-pulse imaging and DCE-MRI communities, and there is scope to place them in a common multi-channel framework to provide better software standardization at the pre-processing de-noising stage. A comprehensive discussion of feature selection strategies is also provided and the importance of preserving textural information is highlighted. Feature extraction and classification methods taking into consideration recent advances in support vector machine (SVM) and extreme learning machine (ELM) classifiers and their complex extensions are presented. An outlook on Clifford algebra classifiers and deep learning techniques suitable to both types of datasets is also provided. The work points toward the direction of developing a new unified multi-channel signal processing framework for biomedical image analysis that will explore synergies from both sensing modalities for inferring disease proliferation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. [Multi-channel in vivo recording techniques: analysis of phase coupling between spikes and rhythmic oscillations of local field potentials].

    Science.gov (United States)

    Wang, Ce-Qun; Chen, Qiang; Zhang, Lu; Xu, Jia-Min; Lin, Long-Nian

    2014-12-25

    The purpose of this article is to introduce the measurements of phase coupling between spikes and rhythmic oscillations of local field potentials (LFPs). Multi-channel in vivo recording techniques allow us to record ensemble neuronal activity and LFPs simultaneously from the same sites in the brain. Neuronal activity is generally characterized by temporal spike sequences, while LFPs contain oscillatory rhythms in different frequency ranges. Phase coupling analysis can reveal the temporal relationships between neuronal firing and LFP rhythms. As the first step, the instantaneous phase of LFP rhythms can be calculated using Hilbert transform, and then for each time-stamped spike occurred during an oscillatory epoch, we marked instantaneous phase of the LFP at that time stamp. Finally, the phase relationships between the neuronal firing and LFP rhythms were determined by examining the distribution of the firing phase. Phase-locked spikes are revealed by the non-random distribution of spike phase. Theta phase precession is a unique phase relationship between neuronal firing and LFPs, which is one of the basic features of hippocampal place cells. Place cells show rhythmic burst firing following theta oscillation within a place field. And phase precession refers to that rhythmic burst firing shifted in a systematic way during traversal of the field, moving progressively forward on each theta cycle. This relation between phase and position can be described by a linear model, and phase precession is commonly quantified with a circular-linear coefficient. Phase coupling analysis helps us to better understand the temporal information coding between neuronal firing and LFPs.

  12. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    Science.gov (United States)

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.

  13. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI

    Science.gov (United States)

    Córcoles, Juan; Zastrow, Earl; Kuster, Niels

    2017-06-01

    The increasing use of multiple radiofrequency (RF) transmit channels in magnetic resonance imaging (MRI) systems makes it necessary to rigorously assess the risk of RF-induced heating. This risk is especially aggravated with inclusions of medical implants within the body. The worst-case RF-heating scenario is achieved when the local tissue deposition in the at-risk region (generally in the vicinity of the implant electrodes) reaches its maximum value while MRI exposure is compliant with predefined general specific absorption rate (SAR) limits or power requirements. This work first reviews the common approach to estimate the worst-case RF-induced heating in multi-channel MRI environment, based on the maximization of the ratio of two Hermitian forms by solving a generalized eigenvalue problem. It is then shown that the common approach is not rigorous and may lead to an underestimation of the worst-case RF-heating scenario when there is a large number of RF transmit channels and there exist multiple SAR or power constraints to be satisfied. Finally, this work derives a rigorous SAR-based formulation to estimate a preferable worst-case scenario, which is solved by casting a semidefinite programming relaxation of this original non-convex problem, whose solution closely approximates the true worst-case including all SAR constraints. Numerical results for 2, 4, 8, 16, and 32 RF channels in a 3T-MRI volume coil for a patient with a deep-brain stimulator under a head imaging exposure are provided as illustrative examples.

  14. Automatic extraction and processing of small RNAs on a multi-well/multi-channel (M&M) chip.

    Science.gov (United States)

    Zhong, Runtao; Flack, Kenneth; Zhong, Wenwan

    2012-12-07

    The study of the regulatory roles in small RNAs can be accelerated by techniques that permit simple, low-cost, and rapid extraction of small RNAs from a small number of cells. In order to ensure highly specific and sensitive detection, the extracted RNAs should be free of the background nucleic acids and present stably in a small volume. To meet these criteria, we designed a multi-well/multi-channel (M&M) chip to carry out automatic and selective isolation of small RNAs via solid-phase extraction (SPE), followed by reverse-transcription (RT) to convert them to the more stable cDNAs in a final volume of 2 μL. Droplets containing buffers for RNA binding, washing, and elution were trapped in microwells, which were connected by one channel, and suspended in mineral oil. The silica magnetic particles (SMPs) for SPE were moved along the channel from well to well, i.e. in between droplets, by a fixed magnet and a translation stage, allowing the nucleic acid fragments to bind to the SMPs, be washed, and then be eluted for RT reaction within 15 minutes. RNAs shorter than 63 nt were selectively enriched from cell lysates, with recovery comparable to that of a commercial kit. Physical separation of the droplets on our M&M chip allowed the usage of multiple channels for parallel processing of multiple samples. It also permitted smooth integration with on-chip RT-PCR, which simultaneously detected the target microRNA, mir-191, expressed in fewer than 10 cancer cells. Our results have demonstrated that the M&M chip device is a valuable and cost-saving platform for studying small RNA expression patterns in a limited number of cells with reasonable sample throughput.

  15. Optimizing Within-Subject Experimental Designs for jICA of Multi-Channel ERP and fMRI

    Science.gov (United States)

    Mangalathu-Arumana, Jain; Liebenthal, Einat; Beardsley, Scott A.

    2018-01-01

    Joint independent component analysis (jICA) can be applied within subject for fusion of multi-channel event-related potentials (ERP) and functional magnetic resonance imaging (fMRI), to measure brain function at high spatiotemporal resolution (Mangalathu-Arumana et al., 2012). However, the impact of experimental design choices on jICA performance has not been systematically studied. Here, the sensitivity of jICA for recovering neural sources in individual data was evaluated as a function of imaging SNR, number of independent representations of the ERP/fMRI data, relationship between instantiations of the joint ERP/fMRI activity (linear, non-linear, uncoupled), and type of sources (varying parametrically and non-parametrically across representations of the data), using computer simulations. Neural sources were simulated with spatiotemporal and noise attributes derived from experimental data. The best performance, maximizing both cross-modal data fusion and the separation of brain sources, occurred with a moderate number of representations of the ERP/fMRI data (10–30), as in a mixed block/event related experimental design. Importantly, the type of relationship between instantiations of the ERP/fMRI activity, whether linear, non-linear or uncoupled, did not in itself impact jICA performance, and was accurately recovered in the common profiles (i.e., mixing coefficients). Thus, jICA provides an unbiased way to characterize the relationship between ERP and fMRI activity across brain regions, in individual data, rendering it potentially useful for characterizing pathological conditions in which neurovascular coupling is adversely affected. PMID:29410611

  16. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.

    Science.gov (United States)

    Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan

    2016-02-01

    This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG +  STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.

  17. An Improved Cloud Classification Algorithm for China's FY-2C Multi-Channel Images Using Artificial Neural Network.

    Science.gov (United States)

    Liu, Yu; Xia, Jun; Shi, Chun-Xiang; Hong, Yang

    2009-01-01

    The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China's first operational geostationary meteorological satellite FengYun-2C (FY-2C) data. First, the capabilities of six widely-used Artificial Neural Network (ANN) methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA) and a Support Vector Machine (SVM), using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm) imagery. The result shows that: (1) ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2) among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM) and Probabilistic Neural Network (PNN). Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  18. An Improved Cloud Classification Algorithm for China’s FY-2C Multi-Channel Images Using Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Chun-Xiang Shi

    2009-07-01

    Full Text Available The crowning objective of this research was to identify a better cloud classification method to upgrade the current window-based clustering algorithm used operationally for China’s first operational geostationary meteorological satellite FengYun-2C (FY-2C data. First, the capabilities of six widely-used Artificial Neural Network (ANN methods are analyzed, together with the comparison of two other methods: Principal Component Analysis (PCA and a Support Vector Machine (SVM, using 2864 cloud samples manually collected by meteorologists in June, July, and August in 2007 from three FY-2C channel (IR1, 10.3-11.3 μm; IR2, 11.5-12.5 μm and WV 6.3-7.6 μm imagery. The result shows that: (1 ANN approaches, in general, outperformed the PCA and the SVM given sufficient training samples and (2 among the six ANN networks, higher cloud classification accuracy was obtained with the Self-Organizing Map (SOM and Probabilistic Neural Network (PNN. Second, to compare the ANN methods to the present FY-2C operational algorithm, this study implemented SOM, one of the best ANN network identified from this study, as an automated cloud classification system for the FY-2C multi-channel data. It shows that SOM method has improved the results greatly not only in pixel-level accuracy but also in cloud patch-level classification by more accurately identifying cloud types such as cumulonimbus, cirrus and clouds in high latitude. Findings of this study suggest that the ANN-based classifiers, in particular the SOM, can be potentially used as an improved Automated Cloud Classification Algorithm to upgrade the current window-based clustering method for the FY-2C operational products.

  19. Investigation of verbal and visual working memory by multi-channel time-resolved functional near-infrared spectroscopy

    Science.gov (United States)

    Contini, D.; Caffini, M.; Re, R.; Zucchelli, L.; Spinelli, L.; Basso Moro, S.; Bisconti, S.; Ferrari, M.; Quaresima, V.; Cutini, S.; Torricelli, A.

    2013-03-01

    Working memory (WM) is fundamental for a number of cognitive processes, such as comprehension, reasoning and learning. WM allows the short-term maintenance and manipulation of the information selected by attentional processes. The goal of this study was to examine by time-resolved fNIRS neural correlates of the verbal and visual WM during forward and backward digit span (DF and DB, respectively) tasks, and symbol span (SS) task. A neural dissociation was hypothesised between the maintenance and manipulation processes. In particular, a dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) recruitment was expected during the DB task, whilst a lateralised involvement of Brodmann Area (BA) 10 was expected during the execution of the DF task. Thirteen subjects were monitored by a multi-channel, dual-wavelength (690 and 829 nm) time-resolved fNIRS system during 3 minutes long DF and DB tasks and 4 minutes long SS task. The participants' mean memory span was calculated for each task: DF: 6.46+/-1.05 digits; DB: 5.62+/-1.26 digits; SS: 4.69+/-1.32 symbols. No correlation was found between the span level and the heart rate data (measured by pulse oximeter). As expected, DB elicited a broad activated area, in the bilateral VLPFC and the right DLPFC, whereas a more localised activation was observed over the right hemisphere during either DF (BA 10) or SS (BA 10 and 44). The robust involvement of the DLPFC during DB, compared to DF, is compatible with previous findings and with the key role of the central executive subserving in manipulating processes.

  20. Use of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer

    Directory of Open Access Journals (Sweden)

    Samuel M Shin

    2015-09-01

    Full Text Available Introduction: Evaluate use of novel multi-channel applicator (MC CapriTM to improve vaginal disease coverage achievable by single-channel applicator (SC and comparable to Syed plan simulation. Material and Methods: 28 plans were evaluated from 4 patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by 3 weekly treatments using HDR brachytherapy with a 13-channel MC. Upper vagina was treated to 5 mm depth to 1500 cGy/3 fractions with a simultaneous integrated boost totaling 2100 cGy/3 fractions to tumor. Modeling of SC and Syed plans was performed using MC scans for each patient. Dosimetry for MC and SC plans was evaluated for PTV700 cGy coverage, maximum dose to 2cm3 to bladder, rectum as well as mucosal surface points. Dosimetry for Syed plans was calculated for PTV700 cGy coverage. Patients were followed for treatment response and toxicity.Results: Dosimetric analysis between MC and SC plans demonstrated increased tumor coverage (PTV700 cGy, with decreased rectal, bladder, and contralateral vaginal mucosa dose in favor of MC. These differences were significant (p<0.05. Comparison of MC and Syed plans demonstrated increased tumor coverage in favor of Syed plans which were not significant (p=0.71. Patients treated with MC had no cancer recurrence or ≥ grade 3 toxicity.Conclusion: Use of MC was efficacious and safe, providing superior coverage of tumor volumes ≤1cm depth compared to SC and comparable to Syed implant. MC avoids excess dose to surrounding organs compared to SC, and potentially less morbidity than Syed implants. For tumors extending ≤1cm depth, use of MC represents an alternative to an interstitial implant.

  1. Effects of runoff harvesting through semi-circular bund on some soil characteristics

    Directory of Open Access Journals (Sweden)

    M. Heshmati

    2018-04-01

    Full Text Available In this study, to investigate the effects of runoff harvesting on soil properties in the semiarid forest, runoff harvesting through semi-circular bund was considered as a method to conserve soil and thereby combat tree mortality. In order to evaluate this hypothesis, runoff was harvested through the semi-circular bund affecting soil quality and moisture storage. The selected forest site is located in Kalehzard, Kermanshah, in Zagros region of western Iran. The experiment was a randomized complete block design with four treatment plots: bund with protection, protection treatment, bund without protection and control treatment. The results showed that the mean values of soil organic carbon in the bund with protection, protection treatment, bund without protection and  control treatment were 2.35, 2.40, 1.90, and 1.80%, respectively, indicating no significant difference among them in the first year, while there were significant (p> 0.05 increases in the bund with protection and protection treatment after three years. Furthermore, coarse and very coarse soil aggregates increased significantly in the bund with protection treatment. This treatment also attributed to significant reduction in soil bulk density from 1.46 (in the first year to 1.32 (in the third year, which enhanced soil moisture content. Finally it was found that bunds with protection significantly curtail dieback and adverse re-growing of stands due to the coupled effects of bund building and protection to curtail forest mortality in the semi-arid regions.

  2. Design, Development and Testing of a Semicircular Type Capacitive Angular Position Sensor

    Directory of Open Access Journals (Sweden)

    Nikhil GAURAV

    2011-06-01

    Full Text Available A low cost semicircular type capacitive angular position sensor has been designed, developed and tested. It is made of two semicircular parallel plates where one plate is fixed and another plate is connected with the rotor whose angular position is to be measured. When the angular position of the rotor changes with respect to the fixed plate, the overlapping area between the two plates of the capacitor is varied causing a change in capacitance value. Capacitance variation obtained due to the change in angular position is in the nano farad range. For signal conditioning, series R-L-C resonating circuit instead of conventional bridge circuit has been used to convert the sensor capacitance variation in to voltage. Experimental result shows that the capacitance for change in angular position 0º-180º increases linearly and for 180º-360º it decreases linearly. To get a linearly increasing response of same slope for the full scale of 0º-360º, a suitable linearising circuit has been designed, developed and tested. Sensor output along with the signal conditioning shows good linearity and repeatability.

  3. Multiple-animal MR imaging using a 3T clinical scanner and multi-channel coil for volumetric analysis in a mouse tumor model

    International Nuclear Information System (INIS)

    Mitsuda, Minoru; Yamaguchi, Masayuki; Furuta, Toshihiro; Fujii, Hirofumi; Nabetani, Akira; Hirayama, Akira; Nozaki, Atsushi; Niitsu, Mamoru

    2011-01-01

    Multiple small-animal magnetic resonance (MR) imaging to measure tumor volume may increase the throughput of preclinical cancer research assessing tumor response to novel therapies. We used a clinical scanner and multi-channel coil to evaluate the usefulness of this imaging to assess experimental tumor volume in mice. We performed a phantom study to assess 2-dimensional (2D) geometric distortion using 9-cm spherical and 32-cell (8 x 4 one-cm 2 grids) phantoms using a 3-tesla clinical MR scanner and dedicated multi-channel coil composed of 16 5-cm circular coils. Employing the multi-channel coil, we simultaneously scanned 6 or 8 mice bearing sarcoma 180 tumors. We estimated tumor volume from the sum of the product of tumor area and slice thickness on 2D spin-echo images (repetition time/echo time, 3500/16 ms; in-plane resolution, 0.195 x 0.195 x 1 mm 3 ). After MR acquisition, we excised and weighed tumors, calculated reference tumor volumes from actual tumor weight assuming a density of 1.05 g/cm 3 , and assessed the correlation between the estimated and reference volumes using Pearson's test. Two-dimensional geometric distortion was acceptable below 5% in the 9-cm spherical phantom and in every cell in the 32-cell phantom. We scanned up to 8 mice simultaneously using the multi-channel coil and found 11 tumors larger than 0.1 g in 12 mice. Tumor volumes were 1.04±0.73 estimated by MR imaging and 1.04±0.80 cm 3 by reference volume (average±standard deviation) and highly correlated (correlation coefficient, 0.995; P<0.01, Pearson's test). Use of multiple small-animal MR imaging employing a clinical scanner and multi-channel coil enabled accurate assessment of experimental tumor volume in a large number of mice and may facilitate high throughput monitoring of tumor response to therapy in preclinical research. (author)

  4. Redundancy or heterogeneity in the electric activity of the biceps brachii muscle? Added value of PCA-processed multi-channel EMG muscle activation estimates in a parallel-fibered muscle

    NARCIS (Netherlands)

    Staudenmann, D.; Stegeman, D.F.; van Dieen, J.H.

    2013-01-01

    Conventional bipolar EMG provides imprecise muscle activation estimates due to possibly heterogeneous activity within muscles and due to improper alignment of the electrodes with the muscle fibers. Principal component analysis (PCA), applied on multi-channel monopolar EMG yielded substantial

  5. GIFT-Grab: Real-time C++ and Python multi-channel video capture, processing and encoding API

    Directory of Open Access Journals (Sweden)

    Dzhoshkun Ismail Shakir

    2017-10-01

    Full Text Available GIFT-Grab is an open-source API for acquiring, processing and encoding video streams in real time. GIFT-Grab supports video acquisition using various frame-grabber hardware as well as from standard-compliant network streams and video files. The current GIFT-Grab release allows for multi-channel video acquisition and encoding at the maximum frame rate of supported hardware – 60 frames per second (fps. GIFT-Grab builds on well-established highly configurable multimedia libraries including FFmpeg and OpenCV. GIFT-Grab exposes a simplified high-level API, aimed at facilitating integration into client applications with minimal coding effort. The core implementation of GIFT-Grab is in C++11. GIFT-Grab also features a Python API compatible with the widely used scientific computing packages NumPy and SciPy. GIFT-Grab was developed for capturing multiple simultaneous intra-operative video streams from medical imaging devices. Yet due to the ubiquity of video processing in research, GIFT-Grab can be used in many other areas. GIFT-Grab is hosted and managed on the software repository of the Centre for Medical Image Computing (CMIC at University College London, and is also mirrored on GitHub. In addition it is available for installation from the Python Package Index (PyPI via the pip installation tool. Funding statement: This work was supported through an Innovative Engineering for Health award by the Wellcome Trust [WT101957], the Engineering and Physical Sciences Research Council (EPSRC [NS/A000027/1] and a National Institute for Health Research Biomedical Research Centre UCLH/UCL High Impact Initiative. Sébastien Ourselin receives funding from the EPSRC (EP/H046410/1, EP/J020990/1, EP/K005278 and the MRC (MR/J01107X/1. Luis C. García-Peraza-Herrera is supported by the EPSRC-funded UCL Centre for Doctoral Training in Medical Imaging (EP/L016478/1.

  6. Osmolarity and root canal antiseptics.

    Science.gov (United States)

    Rossi-Fedele, G; Guastalli, A R

    2014-04-01

    Antiseptics used in endodontics for disinfection purposes include root canal dressings and irrigants. Osmotic shock is known to cause the alteration of microbial cell viability and might have a role in the mechanism of action of root canal antiseptics. The aim of this review was to determine the role of osmolarity on the performance of antiseptics in root canal treatment. A literature search using the Medline electronic database was conducted up to 30 May 2013 using the following search terms and combinations: 'osmolarity AND root canal or endodontic or antiseptic or irrigation or irrigant or medication or dressing or biofilm; osmolality AND root canal or endodontic or antiseptic or irrigation or irrigant or medication or dressing or biofilm; osmotic AND root canal or endodontic or antiseptic or irrigation or irrigant or medication or dressing or biofilm; osmosis AND root canal or endodontic or antiseptic or irrigation or irrigant or medication or dressing or biofilm; sodium chloride AND root canal or endodontic or antiseptic or irrigation or irrigant or medication or dressing or biofilm'. Publications were included if the effects of osmolarity on the clinical performance of antiseptics in root canal treatment were stated, if preparations with different osmolarities values were compared and if they were published in English. A hand search of articles published online, 'in press' and 'early view', and in the reference list of the included papers was carried out following the same criteria. A total of 3274 publications were identified using the database, and three were included in the review. The evidence available in endodontics suggests a possible role for hyperosmotic root canal medicaments as disinfectants, and that there is no influence of osmolarity on the tissue dissolution capacity of sodium hypochlorite. There are insufficient data to obtain a sound conclusion regarding the role of hypo-osmosis in root canal disinfection, or osmosis in any further desirable

  7. Spinal canal stenosis; Spinalkanalstenose

    Energy Technology Data Exchange (ETDEWEB)

    Papanagiotou, P.; Boutchakova, M. [Klinikum Bremen-Mitte/Bremen-Ost, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Bremen (Germany)

    2014-11-15

    Spinal stenosis is a narrowing of the spinal canal by a combination of bone and soft tissues, which can lead to mechanical compression of spinal nerve roots or the dural sac. The lumbal spinal compression of these nerve roots can be symptomatic, resulting in weakness, reflex alterations, gait disturbances, bowel or bladder dysfunction, motor and sensory changes, radicular pain or atypical leg pain and neurogenic claudication. The anatomical presence of spinal canal stenosis is confirmed radiologically with computerized tomography, myelography or magnetic resonance imaging and play a decisive role in optimal patient-oriented therapy decision-making. (orig.) [German] Die Spinalkanalstenose ist eine umschriebene, knoechern-ligamentaer bedingte Einengung des Spinalkanals, die zur Kompression der Nervenwurzeln oder des Duralsacks fuehren kann. Die lumbale Spinalkanalstenose manifestiert sich klinisch als Komplex aus Rueckenschmerzen sowie sensiblen und motorischen neurologischen Ausfaellen, die in der Regel belastungsabhaengig sind (Claudicatio spinalis). Die bildgebende Diagnostik mittels Magnetresonanztomographie, Computertomographie und Myelographie spielt eine entscheidende Rolle bei der optimalen patientenbezogenen Therapieentscheidung. (orig.)

  8. Complete atrioventricular canal.

    Science.gov (United States)

    Calabrò, Raffaele; Limongelli, Giuseppe

    2006-04-05

    Complete atrioventricular canal (CAVC), also referred to as complete atrioventricular septal defect, is characterised by an ostium primum atrial septal defect, a common atrioventricular valve and a variable deficiency of the ventricular septum inflow. CAVC is an uncommon congenital heart disease, accounting for about 3% of cardiac malformations. Atrioventricular canal occurs in two out of every 10,000 live births. Both sexes are equally affected and a striking association with Down syndrome was found. Depending on the morphology of the superior leaflet of the common atrioventricular valve, 3 types of CAVC have been delineated (type A, B and C, according to Rastelli's classification). CAVC results in a significant interatrial and interventricular systemic-to-pulmonary shunt, thus inducing right ventricular pressure and volume overload and pulmonary hypertension. It becomes symptomatic in infancy due to congestive heart failure and failure to thrive. Diagnosis of CAVC might be suspected from electrocardiographic and chest X-ray findings. Echocardiography confirms it and gives anatomical details. Over time, pulmonary hypertension becomes irreversible, thus precluding the surgical therapy. This is the reason why cardiac catheterisation is not mandatory in infants (less than 6 months) but is indicated in older patients if irreversible pulmonary hypertension is suspected. Medical treatment (digitalis, diuretics, vasodilators) plays a role only as a bridge toward surgery, usually performed between the 3rd and 6th month of life.

  9. Complete atrioventricular canal

    Directory of Open Access Journals (Sweden)

    Limongelli Giuseppe

    2006-04-01

    Full Text Available Abstract Complete atrioventricular canal (CAVC, also referred to as complete atrioventricular septal defect, is characterised by an ostium primum atrial septal defect, a common atrioventricular valve and a variable deficiency of the ventricular septum inflow. CAVC is an uncommon congenital heart disease, accounting for about 3% of cardiac malformations. Atrioventricular canal occurs in two out of every 10,000 live births. Both sexes are equally affected and a striking association with Down syndrome was found. Depending on the morphology of the superior leaflet of the common atrioventricular valve, 3 types of CAVC have been delineated (type A, B and C, according to Rastelli's classification. CAVC results in a significant interatrial and interventricular systemic-to-pulmonary shunt, thus inducing right ventricular pressure and volume overload and pulmonary hypertension. It becomes symptomatic in infancy due to congestive heart failure and failure to thrive. Diagnosis of CAVC might be suspected from electrocardiographic and chest X-ray findings. Echocardiography confirms it and gives anatomical details. Over time, pulmonary hypertension becomes irreversible, thus precluding the surgical therapy. This is the reason why cardiac catheterisation is not mandatory in infants (less than 6 months but is indicated in older patients if irreversible pulmonary hypertension is suspected. Medical treatment (digitalis, diuretics, vasodilators plays a role only as a bridge toward surgery, usually performed between the 3rd and 6th month of life.

  10. MR Imaging of the Internal Auditory Canal and Inner Ear at 3T: Comparison between 3D Driven Equilibrium and 3D Balanced Fast Field Echo Sequences

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Jun Soo; Kim, Hyung Jin; Yim, Yoo Jeong; Kim, Sung Tae; Jeon, Pyoung; Kim, Keon Ha [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Sam Soo; Jeon, Yong Hwan; Lee, Ji Won [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2008-06-15

    To compare the use of 3D driven equilibrium (DRIVE) imaging with 3D balanced fast field echo (bFFE) imaging in the assessment of the anatomic structures of the internal auditory canal (IAC) and inner ear at 3 Tesla (T). Thirty ears of 15 subjects (7 men and 8 women; age range, 22 71 years; average age, 50 years) without evidence of ear problems were examined on a whole-body 3T MR scanner with both 3D DRIVE and 3D bFFE sequences by using an 8-channel sensitivity encoding (SENSE) head coil. Two neuroradiologists reviewed both MR images with particular attention to the visibility of the anatomic structures, including four branches of the cranial nerves within the IAC, anatomic structures of the cochlea, vestibule, and three semicircular canals. Although both techniques provided images of relatively good quality, the 3D DRIVE sequence was somewhat superior to the 3D bFFE sequence. The discrepancies were more prominent for the basal turn of the cochlea, vestibule, and all semicircular canals, and were thought to be attributed to the presence of greater magnetic susceptibility artifacts inherent to gradient-echo techniques such as bFFE. Because of higher image quality and less susceptibility artifacts, we highly recommend the employment of 3D DRIVE imaging as the MR imaging choice for the IAC and inner ear

  11. Mechanical nonlinearity elimination with a micromechanical clamped-free semicircular beams resonator

    Science.gov (United States)

    Chen, Dongyang; Chen, Xuying; Wang, Yong; Liu, Xinxin; Guan, Yangyang; Xie, Jin

    2018-04-01

    This paper reports a micro-machined clamped-free semicircular beam resonator aiming to eliminate the nonlinearity that widely exists in traditional mechanical resonators. Cubic coefficients over vibration displacement due to axial extension of the beams are analyzed through theoretical modelling, and the corresponding frequency effect is demonstrated. With the device working in the elastic vibration mode, the cubic coefficients are eliminated by using a free end to release the nonlinear extension of beams and thus the inside axial stress. The amplitude-frequency (A-f) effect is overcome in a large region of source power, and the coefficient of frequency softening is linearized in a large region of polarization voltage. As a result, the resonator can be driven at larger vibration amplitude to achieve a high signal to noise ratio and power handling performance.

  12. Horizontal canal benign paroxysmal positional vertigo: diagnosis and treatment of 37 patients

    Directory of Open Access Journals (Sweden)

    Eliana Teixeira Maranhão

    2015-06-01

    Full Text Available Benign paroxysmal positional vertigo (BPPV, the most frequent cause of vertigo is associated with high morbidity in the elderly population. The most common form is linked to debris in the posterior semicircular canal. However, there has been an increasing number of reported BPPV cases involving the horizontal canals. The purpose of this article is to highlight the clinical features, diagnosis, and treatment in 37 patients with horizontal canal BPPV; twenty-six with geotropic nystagmus, and eleven with the apogeotropic form. Treatment consisted of the Gufoni manoeuver in eighteen patients (48.6%, the barbecue 360° maneuver in twelve patients (32.4%, both manoeuvers in four patients (10.8%, both manoeuvers plus head shaking in one patient (2.7%, and the Gufoni maneuver plus head shaking in two patients. Cupulolithiasis patients were asked to sleep in a forced prolonged position. We obtained a complete resolution of vertigo and nystagmus in 30 patients (81.0% on the initial visit.

  13. Lipoatrofia semicircular: Nuestra experiencia dos años después (2007-2009 Semicircular Lipoatrophy: Our experience two years later (2007-2009

    Directory of Open Access Journals (Sweden)

    Antonio Ortega Díaz de Cevallos

    2009-12-01

    Full Text Available Fundamento y objetivos: Describir y analizar la presentación clínica y la evolución tras la corrección de determinados factores ambientales, de nuestra serie de casos de lipoatrofia semicircular en el entorno laboral, con especial atención a la resolución de la lesión y valorar la posible asociación con otras patologías desde el punto de vista etiológico o que pudieran formar parte de un síndrome más complejo. Pacientes y método: Trabajadores atendidos entre la primavera de 2007 y el verano de 2009. En la primera consulta se efectúa historia clínica detallada, con medición y localización de la lesión, realización de analítica y de ecografía de la zona supuestamente afecta. Posteriormente tras haberse tomado las medidas recomendadas en las empresas para eliminar la electricidad estática, se incluyen controles cada tres meses con anamnesis, exploración física y ecografía comparativas. Resultados: El 96,7% son mujeres, sin predominio de ninguna edad Todos trabajan en puestos con material informático y abundante cableado eléctrico. Las localizaciones, salvo 3 casos (2 en brazo y uno en región glútea, fueron a nivel de cara anterolateral de muslos y con valores medios de 69x20x73 cm. (altoxanchoxlargo. Evolutivamente a los 6 meses un 93% de casos mostraban remisión clínica (62% completa, 31% parcial; al año solamente 2 casos no han mostrado ninguna variación habiendo un 69% de resoluciones completas. Ningún caso ha presentado otra patología relacionada. En el primer año de control hubo 36 nuevos casos, en el segundo 22 y 4 en los 6 meses trascurridos del tercero. Conclusiones: Las características clínicas son superponibles a las de otras series publicadas en cuanto a manifestaciones, tipo de trabajador afecto y predominio de presentación en mujeres. En cuanto a la evolución una vez modificado el entorno laboral, es evidente la tendencia a la resolución, mucho más rápida que en los casos antiguamente

  14. Otolith and Vertical Canal Contributions to Dynamic Postural Control

    Science.gov (United States)

    Black, F. Owen

    1999-01-01

    The objective of this project is to determine: 1) how do normal subjects adjust postural movements in response to changing or altered otolith input, for example, due to aging? and 2) how do patients adapt postural control after altered unilateral or bilateral vestibular sensory inputs such as ablative inner ear surgery or ototoxicity, respectively? The following hypotheses are under investigation: 1) selective alteration of otolith input or abnormalities of otolith receptor function will result in distinctive spatial, frequency, and temporal patterns of head movements and body postural sway dynamics. 2) subjects with reduced, altered, or absent vertical semicircular canal receptor sensitivity but normal otolith receptor function or vice versa, should show predictable alterations of body and head movement strategies essential for the control of postural sway and movement. The effect of altered postural movement control upon compensation and/or adaptation will be determined. These experiments provide data for the development of computational models of postural control in normals, vestibular deficient subjects and normal humans exposed to unusual force environments, including orbital space flight.

  15. Multi-channel WDM RZ-to-NRZ format conversion at 50 Gbit/s based on single silicon microring resonator

    DEFF Research Database (Denmark)

    Ding, Yunhong; Peucheret, Christophe; Pu, Minhao

    2010-01-01

    We comprehensively analyze multiple WDM channels RZ-to- NRZ format conversion using a single microring resonator. The scheme relies on simultaneous suppression of the first order harmonic components in the spectra of all the RZ channels. An optimized silicon microring resonator with free spectral...... range of 100 GHz and Q value of 7900 is designed and fabricated for this purpose. Multi-channel RZ-to-NRZ format conversion is demonstrated experimentally at 50 Gbit/s for WDM channels with 200 GHz channel spacing using the fabricated device. Bit error rate (BER)measurements show very good conversion...

  16. On the Efficiency of the Multi-Channel Analysis of Surface Wave Method for Shallow and Semi-Deep Loose Soil Layers

    Directory of Open Access Journals (Sweden)

    Kasgin Khaheshi Banab

    2010-01-01

    Full Text Available The multi-channel analysis of surface waves (MASWs method was used to obtain the shear wave velocity variations through near surface (depth 2,300 m/s is very large. The MASW velocity results compared with those of other geophysical approaches, such as seismic reflection/refraction methods and borehole data, where available, mostly confirming the capability of the MASW method to distinguish the high shear wave velocity contrast in the study area. We have found that, of the inversion procedures of MASW data, the random search inversion technique provides better results than the analytical generalized inversion method.

  17. Unilateral posterior canal-plugging surgery for intractable bilateral posterior canal-type benign paroxysmal positional vertigo.

    Science.gov (United States)

    Hotta, Sayaka; Imai, Takao; Higashi-Shingai, Kayoko; Okazaki, Suzuyo; Okumura, Tomoko; Uno, Atsuhiko; Ohta, Yumi; Morihana, Tetsuo; Sato, Takashi; Inohara, Hidenori

    2017-10-01

    To investigate the effectiveness of unilateral posterior semicircular canal (PSCC)-plugging surgery for patients with intractable bilateral PSCC-type benign paroxysmal positional vertigo (P-BPPV). From July 2011 to December 2015, we diagnosed 136 patients with P-BPPV. Of these, 3 patients had bilateral P-BPPV, and in 2 of the 3, the condition had been refractory to conservative treatment for more than 1 year. We planned a staged PSCC-plugging surgery for these 2 patients; initially one side was treated, and the contralateral side was treated 6 months later. After the first surgery, both patients experienced improvement in symptoms of vertigo and nystagmus on the operated side and no change on the non-operated side. Patients underwent the Epley maneuver for the non-operated side. In one case, the non-operated side was cured. In the other case, although the P-BPPV was not completely resolved, the patient was satisfied with the result of unilateral surgery because he was now able to turn in bed to the operated side without vertigo. Before surgery, he had experienced vertigo when turning even slightly in bed. We propose that even unilateral PSCC-plugging surgery is effective for some patients with intractable bilateral P-BPPV. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Hood Canal Steelhead - Hood Canal Steelhead Supplementation Experiment

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Hood Canal Steelhead Project is a 17-year before-after-control-impact experiment that tests the effects of supplementation on natural steelhead populations in...

  19. Multi-channel ground-penetrating radar to explore spatial variations in thaw depth and moisture content in the active layer of a permafrost site

    Directory of Open Access Journals (Sweden)

    U. Wollschläger

    2010-08-01

    Full Text Available Multi-channel ground-penetrating radar (GPR was applied at a permafrost site on the Tibetan Plateau to investigate the influence of surface properties and soil texture on the late-summer thaw depth and average soil moisture content of the active layer. Measurements were conducted on an approximately 85 × 60 m2 sized area with surface and soil textural properties that ranged from medium to coarse textured bare soil to finer textured, sparsely vegetated areas covered with fine, wind blown sand, and it included the bed of a gravel road. The survey allowed a clear differentiation of the various units. It showed (i a shallow thaw depth and low average soil moisture content below the sand-covered, vegetated area, (ii an intermediate thaw depth and high average soil moisture content along the gravel road, and (iii an intermediate to deep thaw depth and low to intermediate average soil moisture content in the bare soil terrain. From our measurements, we found hypotheses for the permafrost processes at this site leading to the observed late-summer thaw depth and soil moisture conditions. The study clearly indicates the complicated interactions between surface and subsurface state variables and processes in this environment. Multi-channel GPR is an operational technology to efficiently study such a system at scales varying from a few meters to a few kilometers.

  20. Continuous Estimates of Surface Density and Annual Snow Accumulation with Multi-Channel Snow/Firn Penetrating Radar in the Percolation Zone, Western Greenland Ice Sheet

    Science.gov (United States)

    Meehan, T.; Marshall, H. P.; Bradford, J.; Hawley, R. L.; Osterberg, E. C.; McCarthy, F.; Lewis, G.; Graeter, K.

    2017-12-01

    A priority of ice sheet surface mass balance (SMB) prediction is ascertaining the surface density and annual snow accumulation. These forcing data can be supplied into firn compaction models and used to tune Regional Climate Models (RCM). RCMs do not accurately capture subtle changes in the snow accumulation gradient. Additionally, leading RCMs disagree among each other and with accumulation studies in regions of the Greenland Ice Sheet (GrIS) over large distances and temporal scales. RCMs tend to yield inconsistencies over GrIS because of sparse and outdated validation data in the reanalysis pool. Greenland Traverse for Accumulation and Climate Studies (GreenTrACS) implemented multi-channel 500 MHz Radar in multi-offset configuration throughout two traverse campaigns totaling greater than 3500 km along the western percolation zone of GrIS. The multi-channel radar has the capability of continuously estimating snow depth, average density, and annual snow accumulation, expressed at 95% confidence (+-) 0.15 m, (+-) 17 kgm-3, (+-) 0.04 m w.e. respectively, by examination of the primary reflection return from the previous year's summer surface.

  1. Development of slew-rate-limited time-over-threshold (ToT) ASIC for a multi-channel silicon-based ion detector

    Science.gov (United States)

    Uenomachi, M.; Orita, T.; Shimazoe, K.; Takahashi, H.; Ikeda, H.; Tsujita, K.; Sekiba, D.

    2018-01-01

    High-resolution Elastic Recoil Detection Analysis (HERDA), which consists of a 90o sector magnetic spectrometer and a position-sensitive detector (PSD), is a method of quantitative hydrogen analysis. In order to increase sensitivity, a HERDA system using a multi-channel silicon-based ion detector has been developed. Here, as a parallel and fast readout circuit from a multi-channel silicon-based ion detector, a slew-rate-limited time-over-threshold (ToT) application-specific integrated circuit (ASIC) was designed, and a new slew-rate-limited ToT method is proposed. The designed ASIC has 48 channels and each channel consists of a preamplifier, a slew-rate-limited shaping amplifier, which makes ToT response linear, and a comparator. The measured equivalent noise charges (ENCs) of the preamplifier, the shaper, and the ToT on no detector capacitance were 253±21, 343±46, and 560±56 electrons RMS, respectively. The spectra from a 241Am source measured using a slew-rate-limited ToT ASIC are also reported.

  2. Multi-DSP and FPGA based Multi-channel Direct IF/RF Digital receiver for atmospheric radar

    Science.gov (United States)

    Yasodha, Polisetti; Jayaraman, Achuthan; Kamaraj, Pandian; Durga rao, Meka; Thriveni, A.

    2016-07-01

    Modern phased array radars depend highly on digital signal processing (DSP) to extract the echo signal information and to accomplish reliability along with programmability and flexibility. The advent of ASIC technology has made various digital signal processing steps to be realized in one DSP chip, which can be programmed as per the application and can handle high data rates, to be used in the radar receiver to process the received signal. Further, recent days field programmable gate array (FPGA) chips, which can be re-programmed, also present an opportunity to utilize them to process the radar signal. A multi-channel direct IF/RF digital receiver (MCDRx) is developed at NARL, taking the advantage of high speed ADCs and high performance DSP chips/FPGAs, to be used for atmospheric radars working in HF/VHF bands. Multiple channels facilitate the radar t be operated in multi-receiver modes and also to obtain the wind vector with improved time resolution, without switching the antenna beam. MCDRx has six channels, implemented on a custom built digital board, which is realized using six numbers of ADCs for simultaneous processing of the six input signals, Xilinx vertex5 FPGA and Spartan6 FPGA, and two ADSPTS201 DSP chips, each of which performs one phase of processing. MCDRx unit interfaces with the data storage/display computer via two gigabit ethernet (GbE) links. One of the six channels is used for Doppler beam swinging (DBS) mode and the other five channels are used for multi-receiver mode operations, dedicatedly. Each channel has (i) ADC block, to digitize RF/IF signal, (ii) DDC block for digital down conversion of the digitized signal, (iii) decoding block to decode the phase coded signal, and (iv) coherent integration block for integrating the data preserving phase intact. ADC block consists of Analog devices make AD9467 16-bit ADCs, to digitize the input signal at 80 MSPS. The output of ADC is centered around (80 MHz - input frequency). The digitized data is fed

  3. Combined use of ultrasonic-assisted liposuction and semicircular periareolar incision for the treatment of gynecomastia.

    Science.gov (United States)

    Esme, Danielle L; Beekman, Werner H; Hage, J Joris; Nipshagen, Martine D

    2007-12-01

    Of the wide range of excisional and liposuction techniques used to correct gynecomastia, so far, no single one was suitable for all grades of gynecomastia. We introduce ultrasonic-assisted liposuction (UAL) combined with conventional liposuction and partial gland resection without skin excision as the standard surgical technique for all such grades. Twenty-eight men (aged 17 to 80 years) were consecutively treated from March 2004 through April 2006 for grade Ia (n = 3), Ib (n = 2), IIa (n = 6), IIb (n = 6), III (n = 8), or IV (n = 3) gynecomastia. Their characteristics and the outcome of surgery were retrospectively assessed. A mean of 848 mL (range, 300 to 1400 mL) of liquefied breast tissue was aspirated, and 31 g (range, 3 to 180 g) of fibroglandular tissue were excised per breast. No immediate or delayed adjuvant skin reduction was needed in any of the patients. Moderate postoperative ecchymosis was observed in 2 patients, but no complications were encountered in this series. The cosmetic outcome was good to excellent in all. UAL in combination with gland resection through a minimal caudal semicircular periareolar incision and conventional liposuction effectively corrects all grades of gynecomastia. This combination has little morbidity, requires no skin excision, and leads to uniformly good esthetic results.

  4. El Canal del Atazar I

    Directory of Open Access Journals (Sweden)

    López de Berges y de los Santos, Emilio

    1967-03-01

    Full Text Available The Atazar Canal helps to supply Madrid with water, from the rivers Lozoya, Jarama and Sorbe. The section which operates at present starts at the Torrelaguna dam and finishes at the El Goloso reservoir. Later a further section will be added, from the Atazar dam, on the Lozoya river, to link up with the control dam at Torrelaguna. The canal capacity is 16 m3/sec, and it is 43.47 km long. It has a slope of 4/10.000. The cross section is similar to that of the Jarama canal, already built. There are interconnections between this canal and the Canal Alto, which previously supplied the high and medium part of Madrid. To overcome the ground unevenness 5 syphons have been built, the most important of which is the Colmenar Goloso syphon, which is 10.88 km in length. Construction commenced on December 10, 1962, and water reached Madrid on June 15th, 1966. The initial budget for this project was 1,500 million pesetas.El canal del Atazar refuerza considerablemente el abastecimiento de aguas a Madrid, procedentes de los ríos Lozoya, Jarama y, en un próximo futuro, del Sorbe. El tramo, actualmente en funcionamiento, empieza en el salto de Torrelaguna y finaliza en los depósitos de El Goloso. Más adelante se completará su trazado mediante un nuevo tramo que partirá del embalse de Atazar, en el Lozoya, para unirse al actual en el depósito regulador de Torrelaguna. Su capacidad es de 16 m3/s; su longitud, 43,471 km, y su pendiente, 4 diezmilésimas. La sección tipo es análoga a la del canal del Jarama, de construcción anterior. Mediante la oportuna obra de transvase se realizan intercambios entre este Canal y el Canal Alto que abastecía anteriormente la parte media y alta de la capital. Para salvar los desniveles del terreno se han construido 5 sifones, siendo el más importante el de Colmenar-Goloso, con una longitud de 10,8S4 km. El comienzo de las obras tuvo lugar el 10 de diciembre de 1962, y el agua llegó a Madrid el 15 de junio de 1966. Su

  5. A simple and highly selective 2,2-diferrocenylpropane-based multi-channel ion pair receptor for Pb(2+) and HSO4(-).

    Science.gov (United States)

    Wan, Qian; Zhuo, Ji-Bin; Wang, Xiao-Xue; Lin, Cai-Xia; Yuan, Yao-Feng

    2015-03-28

    A structurally simple, 2,2-diferrocenylpropane-based ion pair receptor 1 was synthesized and characterized by (1)H NMR, (13)C NMR, HRMS, elemental analyses, and single-crystal X-ray diffraction. The ion pair receptor 1 showed excellent selectivity and sensitivity towards Pb(2+) with multi-channel responses: a fluorescence enhancement (more than 42-fold), a notable color change from yellow to red, redox anodic shift (ΔE1/2 = 151 mV), while HSO4(-) promoted fluorescence enhancement when Pb(2+) or Zn(2+) was bonded to the cation binding-site. (1)H NMR titration and density functional theory were performed to reveal the sensing mechanism based on photo-induced electron transfer (PET).

  6. Investigating the astrophysical 22Ne(p, γ23Na and 22Mg(p, γ23Al reactions with a multi-channel scattering formalism

    Directory of Open Access Journals (Sweden)

    Fraser P. R.

    2014-03-01

    Full Text Available The reaction 22Ne(p, γ23Na is key to the NeNa cycle of stellar nucleogenesis, and better understanding of the 22Mg(p, γ23Al reaction is needed to understand the 22Na puzzle in ONe white dwarf novae. We aim to study these reactions using a multi-channel algebraic scattering (MCAS formalism for low-energy nucleon-nucleus scattering, recently expanded to investigate radiative capture. As a first step towards this goal, we here calculate the energy levels of the mass-23 (Ne, Mg, Na, Al nuclei. This is not only because the resonant structure of these nuclei are related to the astrophysical -rates of interest, but also because the interaction parameters determined for describing the energy levels are an integral part of the future calculation of the astrophysical reactions when using the MCAS scheme.

  7. The investigation of multi-channel splitters and big-bend waveguides based on 2D sunflower-typed photonic crystals

    Science.gov (United States)

    Liu, Wei; Sun, XiaoHong; Fan, QingBin; Wang, Shuai; Qi, YongLe

    2016-12-01

    Different kinds of multi-channel splitters and big-bend waveguides have been designed and investigated by using sunflower-typed photonic crystals. By comparing the transmission spectra of two kinds of 4-channels beam splitters, we find that "C" type splitter has a relative uniform splitting ratio for different channels in a certain wavelength range. Furthermore three types of waveguides with different bending degrees have been investigated. Except for a little loss in the short wavelength with the increase of the bending degrees, they have almost the same transmission spectra structures. The result can be extended to big-bend waveguides with arbitrary bending degrees. This research is valuable for developing new-typed integrated optical communication devices.

  8. Encoding of rat working memory by power of multi-channel local field potentials via sparse non-negative matrix factorization

    Institute of Scientific and Technical Information of China (English)

    Xu Liu; Tiao-Tiao Liu; Wen-Wen Bai; Hu Yi; Shuang-Yan Li; Xin Tian

    2013-01-01

    Working memory plays an important role in human cognition.This study investigated how working memory was encoded by the power of multi-channel local field potentials (LFPs) based on sparse nonnegative matrix factorization (SNMF).SNMF was used to extract features from LFPs recorded from the prefrontal cortex of four Sprague-Dawley rats during a memory task in a Y maze,with 10 trials for each rat.Then the power-increased LFP components were selected as working memory-related features and the other components were removed.After that,the inverse operation of SNMF was used to study the encoding of working memory in the timefrequency domain.We demonstrated that theta and gamma power increased significantly during the working memory task.The results suggested that postsynaptic activity was simulated well by the sparse activity model.The theta and gamma bands were meaningful for encoding working memory.

  9. Experimental and theoretical study of hydrodynamic cell lysing of cancer cells in a high-throughput Circular Multi-Channel Microfiltration device

    KAUST Repository

    Ma, W.

    2013-04-01

    Microfiltration is an important microfluidic technique suitable for enrichment and isolation of cells. However, cell lysing could occur due to hydrodynamic damage that may be detrimental for medical diagnostics. Therefore, we conducted a systematic study of hydrodynamic cell lysing in a high-throughput Circular Multi-Channel Microfiltration (CMCM) device integrated with a polycarbonate membrane. HeLa cells (cervical cancer cells) were driven into the CMCM at different flow rates. The viability of the cells in the CMCM was examined by fluorescence microscopy using Acridine Orange (AO)/Ethidium Bromide (EB) as a marker for viable/dead cells. A simple analytical cell viability model was derived and a 3D numerical model was constructed to examine the correlation of between cell lysing and applied shear stress under varying flow rate and Reynolds number. The measured cell viability as a function of the shear stress was consistent with theoretical and numerical predictions when accounting for cell size distribution. © 2013 IEEE.

  10. Experimental and theoretical study of hydrodynamic cell lysing of cancer cells in a high-throughput Circular Multi-Channel Microfiltration device

    KAUST Repository

    Ma, W.; Liu, D.; Shagoshtasbi, H.; Shukla, A.; Nugroho, E. S.; Zohar, Y.; Lee, Y.-K.

    2013-01-01

    Microfiltration is an important microfluidic technique suitable for enrichment and isolation of cells. However, cell lysing could occur due to hydrodynamic damage that may be detrimental for medical diagnostics. Therefore, we conducted a systematic study of hydrodynamic cell lysing in a high-throughput Circular Multi-Channel Microfiltration (CMCM) device integrated with a polycarbonate membrane. HeLa cells (cervical cancer cells) were driven into the CMCM at different flow rates. The viability of the cells in the CMCM was examined by fluorescence microscopy using Acridine Orange (AO)/Ethidium Bromide (EB) as a marker for viable/dead cells. A simple analytical cell viability model was derived and a 3D numerical model was constructed to examine the correlation of between cell lysing and applied shear stress under varying flow rate and Reynolds number. The measured cell viability as a function of the shear stress was consistent with theoretical and numerical predictions when accounting for cell size distribution. © 2013 IEEE.

  11. Integration of canal and otolith inputs by central vestibular neurons is subadditive for both active and passive self-motion: implication for perception.

    Science.gov (United States)

    Carriot, Jerome; Jamali, Mohsen; Brooks, Jessica X; Cullen, Kathleen E

    2015-02-25

    Traditionally, the neural encoding of vestibular information is studied by applying either passive rotations or translations in isolation. However, natural vestibular stimuli are typically more complex. During everyday life, our self-motion is generally not restricted to one dimension, but rather comprises both rotational and translational motion that will simultaneously stimulate receptors in the semicircular canals and otoliths. In addition, natural self-motion is the result of self-generated and externally generated movements. However, to date, it remains unknown how information about rotational and translational components of self-motion is integrated by vestibular pathways during active and/or passive motion. Accordingly, here, we compared the responses of neurons at the first central stage of vestibular processing to rotation, translation, and combined motion. Recordings were made in alert macaques from neurons in the vestibular nuclei involved in postural control and self-motion perception. In response to passive stimulation, neurons did not combine canal and otolith afferent information linearly. Instead, inputs were subadditively integrated with a weighting that was frequency dependent. Although canal inputs were more heavily weighted at low frequencies, the weighting of otolith input increased with frequency. In response to active stimulation, neuronal modulation was significantly attenuated (∼ 70%) relative to passive stimulation for rotations and translations and even more profoundly attenuated for combined motion due to subadditive input integration. Together, these findings provide insights into neural computations underlying the integration of semicircular canal and otolith inputs required for accurate posture and motor control, as well as perceptual stability, during everyday life. Copyright © 2015 the authors 0270-6474/15/353555-11$15.00/0.

  12. Biphasic DC measurement approach for enhanced measurement stability and multi-channel sampling of self-sensing multi-functional structural materials doped with carbon-based additives

    Science.gov (United States)

    Downey, Austin; D'Alessandro, Antonella; Ubertini, Filippo; Laflamme, Simon; Geiger, Randall

    2017-06-01

    Investigation of multi-functional carbon-based self-sensing structural materials for structural health monitoring applications is a topic of growing interest. These materials are self-sensing in the sense that they can provide measurable electrical outputs corresponding to physical changes such as strain or induced damage. Nevertheless, the development of an appropriate measurement technique for such materials is yet to be achieved, as many results in the literature suggest that these materials exhibit a drift in their output when measured with direct current (DC) methods. In most of the cases, the electrical output is a resistance and the reported drift is an increase in resistance from the time the measurement starts due to material polarization. Alternating current methods seem more appropriate at eliminating the time drift. However, published results show they are not immune to drift. Moreover, the use of multiple impedance measurement devices (LCR meters) does not allow for the simultaneous multi-channel sampling of multi-sectioned self-sensing materials due to signal crosstalk. The capability to simultaneously monitor multiple sections of self-sensing structural materials is needed to deploy these multi-functional materials for structural health monitoring. Here, a biphasic DC measurement approach with a periodic measure/discharge cycle in the form of a square wave sensing current is used to provide consistent, stable resistance measurements for self-sensing structural materials. DC measurements are made during the measurement region of the square wave while material depolarization is obtained during the discharge region of the periodic signal. The proposed technique is experimentally shown to remove the signal drift in a carbon-based self-sensing cementitious material while providing simultaneous multi-channel measurements of a multi-sectioned self-sensing material. The application of the proposed electrical measurement technique appears promising for real

  13. Closed-Loop Neuroprosthesis for Reach-to-Grasp Assistance: Combining Adaptive Multi-channel Neuromuscular Stimulation with a Multi-joint Arm Exoskeleton.

    Science.gov (United States)

    Grimm, Florian; Gharabaghi, Alireza

    2016-01-01

    Stroke patients with severe motor deficits cannot execute task-oriented rehabilitation exercises with their affected upper extremity. Advanced rehabilitation technology may support them in performing such reach-to-grasp movements. The challenge is, however, to provide assistance as needed, while maintaining the participants' commitment during the exercises. In this feasibility study, we introduced a closed-loop neuroprosthesis for reach-to-grasp assistance which combines adaptive multi-channel neuromuscular stimulation with a multi-joint arm exoskeleton. Eighteen severely affected chronic stroke patients were assisted by a gravity-compensating, seven-degree-of-freedom exoskeleton which was attached to the paretic arm for performing reach-to-grasp exercises resembling activities of daily living in a virtual environment. During the exercises, adaptive electrical stimulation was applied to seven different muscles of the upper extremity in a performance-dependent way to enhance the task-oriented movement trajectory. The stimulation intensity was individualized for each targeted muscle and remained subthreshold, i.e., induced no overt support. Closed-loop neuromuscular stimulation could be well integrated into the exoskeleton-based training, and increased the task-related range of motion (p = 0.0004) and movement velocity (p = 0.015), while preserving accuracy. The highest relative stimulation intensity was required to facilitate the grasping function. The facilitated range of motion correlated with the upper extremity Fugl-Meyer Assessment score of the patients (p = 0.028). Combining adaptive multi-channel neuromuscular stimulation with antigravity assistance amplifies the residual motor capabilities of severely affected stroke patients during rehabilitation exercises and may thus provide a customized training environment for patient-tailored support while preserving the participants' engagement.

  14. Closed-Loop Neuroprosthesis for Reach-to-Grasp Assistance: Combining Adaptive Multi-channel Neuromuscular Stimulation with a Multi-joint Arm Exoskeleton

    Science.gov (United States)

    Grimm, Florian; Gharabaghi, Alireza

    2016-01-01

    Stroke patients with severe motor deficits cannot execute task-oriented rehabilitation exercises with their affected upper extremity. Advanced rehabilitation technology may support them in performing such reach-to-grasp movements. The challenge is, however, to provide assistance as needed, while maintaining the participants' commitment during the exercises. In this feasibility study, we introduced a closed-loop neuroprosthesis for reach-to-grasp assistance which combines adaptive multi-channel neuromuscular stimulation with a multi-joint arm exoskeleton. Eighteen severely affected chronic stroke patients were assisted by a gravity-compensating, seven-degree-of-freedom exoskeleton which was attached to the paretic arm for performing reach-to-grasp exercises resembling activities of daily living in a virtual environment. During the exercises, adaptive electrical stimulation was applied to seven different muscles of the upper extremity in a performance-dependent way to enhance the task-oriented movement trajectory. The stimulation intensity was individualized for each targeted muscle and remained subthreshold, i.e., induced no overt support. Closed-loop neuromuscular stimulation could be well integrated into the exoskeleton-based training, and increased the task-related range of motion (p = 0.0004) and movement velocity (p = 0.015), while preserving accuracy. The highest relative stimulation intensity was required to facilitate the grasping function. The facilitated range of motion correlated with the upper extremity Fugl-Meyer Assessment score of the patients (p = 0.028). Combining adaptive multi-channel neuromuscular stimulation with antigravity assistance amplifies the residual motor capabilities of severely affected stroke patients during rehabilitation exercises and may thus provide a customized training environment for patient-tailored support while preserving the participants' engagement. PMID:27445658

  15. Effects on humans elicited by inhaling the fragrance of essential oils: sensory test, multi-channel thermometric study and forehead surface potential wave measurement on basil and peppermint.

    Science.gov (United States)

    Satoh, Tomoko; Sugawara, Yoshiaki

    2003-01-01

    The effects on humans inhaling the fragrance of essential oils were examined in terms of a sensory test, a multi-channel skin thermometer study and a portable forehead surface electroencephalographic (IBVA-EEG) measurement. The essential oils examined in this study were those of basil and peppermint, because our previous sensory test had indicated an opposite effect of these essential oils when mental work was undertaken; the inhalation of basil produced a more favorable impression after work than before work, whereas peppermint produced an unfavorable impression under these circumstances. For subjects administered basil or peppermint before and after mental work using an inhalator, a series of multi-channel skin thermometer studies and IBVA-EEG measurements were conducted. Using such paired odorants, our results showed that when compared between before and after mental work assigned to subjects: (1) the inhalation of basil, in which a favorable impression was predominant on the whole in terms of the sensory evaluation spectrum, was shown to be associated upward tendency in finger-tip skin temperature; (2) whereas these situations were opposite in the case of peppermint, in which the reversed (unfavorable) feature in sensory profiling was accompanied by a decrease in the magnitude of beta waves and a decrease in the finger-tip skin temperature both based on Welch's method, even at p < 0.01, implying a decreasing propensity of the aroused state and of the arousal response. The elucidation of such sensory and physiological endpoints of paired odorants would be of primary importance for human chemoreception science, because these are only rarely recorded during the same experiments, and this paradigm is highly informative about non-verbal responses to odorants.

  16. SU-G-TeP2-07: Dosimetric Characterization of a New HDR Multi-Channel Esophageal Applicator for Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, A; Gao, S; Greskovich, J; Wilkinson, D [Cleveland Clinic, Cleveland, OH (United States); Diener, T [Cleveland State University, Cleveland, OH (United States)

    2016-06-15

    Purpose: To characterize the dose distribution of a new multi-channel esophageal applicator for brachytherapy HDR treatment, and particularly the effect of the presence of air or water in the applicator’s expansion balloon. Methods: A new multi-channel (6) inflatable applicator for esophageal HDR has been developed in house and tested in a simple water phantom. CT image sets were obtained under several balloon expansions (80ml of air, 50 cc of water), and channel loadings and used with the Oncentra (Elekta) planning system based on TG43 formalism. 400 cGy was prescribed to a plane 1cm away from the applicator. Planar dose distributions were measured for that plane and one next to the applicator using Gafchromic EBT3 film and scanned by a Vidar VXR-12 film digitizer. Film and TPS generated dose distributions of film were sent to OmniPro I’mRT (iba DOSIMETRY) for analysis. 2D dose profiles in both X and Y directions were compared and gamma analysis performed. Results: Film dose measurement of the air-inflated applicator is lower than the TPS calculated dose by as much as 60%. Only 80.8% of the pixels passed the gamma criteria (3%/3mm). For the water-inflated applicator, the measured film dose is fairly close to the TPS calculated dose (typically within <3%). 99.84% of the pixels passed the gamma criteria (3%/3mm). Conclusion: TG43 based calculations worked well when water was used in the expansion balloon. However, when air is present in that balloon, the neglect of heterogeneity corrections in the TG43 calculation results in large differences between calculated and measured doses. This could result in severe underdosing when used in a patient. This study illustrates the need for a TPS with an advanced algorithm which can account for heterogeneity. Supported by Innovations Department, Cleveland Clinic.

  17. Reduced but broader prefrontal activity in patients with schizophrenia during n-back working memory tasks: a multi-channel near-infrared spectroscopy study.

    Science.gov (United States)

    Koike, Shinsuke; Takizawa, Ryu; Nishimura, Yukika; Kinou, Masaru; Kawasaki, Shingo; Kasai, Kiyoto

    2013-09-01

    Caudal regions of the prefrontal cortex, including the dorsolateral (DLPFC) and ventrolateral (VLPFC) prefrontal cortex, are involved in essential cognitive functions such as working memory. In contrast, more rostral regions, such as the frontopolar cortex (FpC), have integrative functions among cognitive functions and thereby contribute crucially to real-world social activity. Previous functional magnetic resonance imaging studies have shown patients with schizophrenia had different DLPFC activity pattern in response to cognitive load changes compared to healthy controls; however, the spatial relationship between the caudal and rostral prefrontal activation has not been evaluated under less-constrained conditions. Twenty-six patients with schizophrenia and 26 age-, sex-, and premorbid-intelligence-matched healthy controls participated in this study. Hemodynamic changes during n-back working memory tasks with different cognitive loads were measured using multi-channel near-infrared spectroscopy (NIRS). Healthy controls showed significant task-related activity in the bilateral VLPFC and significant task-related decreased activity in the DLPFC, with greater signal changes when the task required more cognitive load. In contrast, patients with schizophrenia showed activation in the more rostral regions, including bilateral DLPFC and FpC. Neither decreased activity nor greater activation in proportion to elevated cognitive load occurred. This multi-channel NIRS study demonstrated that activation intensity did not increase in patients with schizophrenia associated with cognitive load changes, suggesting hypo-frontality as cognitive impairment in schizophrenia. On the other hand, patients had broader prefrontal activity in areas such as the bilateral DLPFC and FpC regions, thus suggesting a hyper-frontality compensatory response. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Unpredictable Root Canal Morphology: Expect the Unexpected

    Directory of Open Access Journals (Sweden)

    Sohez J Makani

    2015-01-01

    Full Text Available Background: A maxillary first molar with more than four canals is an interesting example of anatomic variations, especially when two of these canals are detected, with separate apical foramen in the distal root. The inability to locate the unexpected canals of various anatomical configuration and subsequently treat them , may lead to therapeutic failures. Endodontic retreatment is usually the modality of choice in such cases. This report describes a case of a maxillary first molar with five canals (two mesial canals in mesial root, two distal canals in two distal roots and a palatal canal in palatal root. Additionally it shows a rare anatomic configuration and emphasizes the importance of identifying additional canals.

  19. [Treatment of gynecomastia by a combined method of liposuction and semicircular periareolar incision glandular organ partial resection].

    Science.gov (United States)

    Liu, Su; Kuang, Ruixia; Chen, Zhenyu; Li, Huichao; Zhang, Weina; Wang, Zhiguo; Miao, Yuanxin; Chen, Lu

    2008-12-01

    To evaluate the effect of the combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia. From June 2004 to June 2006, 40 patients, aged 11-41 years old, were treated, with no-nodule (n = 10), nodule (n = 22) and female-breast-like with nodules (n = 8). Three patients were unilateral and 37 ones were bilateral. The levels of serum prolactin, luteinizing hormone, follicle stimulating hormone, estradiol, testosterone and cortisol were normal in 38 patients, while in the other 2 patients, the levels of serum prolactin, luteinizing hormone, follicle stimulating hormone and estradiol were higher than normal, and the testosterone level was lower. Liposuction alone was performed in 10 no-nodule patients (lipo-type), and combined liposuction and semicircular periareolar incision glandular organ partial resection were conducted in the other 30 patients (lipo-glandular type). RESULTS; Except for 2 cases in which hematoma and a small amount of effusion were found on the first and second day postoperatively and then obtained healing by first intention right after hematoma removal in time, all the other patients incisions obtained healing by first intention. Nipple numbness occurred in 3 cases on the first day postoperatively and no special treatment was conducted. There was still nipple hypesthesia in these 3 cases after 6-month follow-up. There were no complications such as hematoma, effusion, nipple and mammary areola necrosis, and nipple hypesthesia in other patients. All the 40 patients were followed up for 6-24 months (13 months on average). They were satisfied with their chest figures and no recurrence was observed. The combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia has many advantages, such as safe, micro-scars, natural and beautiflhl male breast figures as well as high patients' satisfaction.

  20. Preliminary Interpretations of Multi-Channel Seismic Reflection and Magnetic Data on North Anatolian Fault (NAF) in the Eastern Marmara Region, Turkey

    Science.gov (United States)

    Gözde Okut Toksoy, Nigar; Kurt, Hülya; İşseven, Turgay

    2017-04-01

    The North Anatolian Fault (NAF) is 1600 km long, right lateral strike-slip fault nearly E-W elongated between Karlıova in the east and Saros Gulf in the west. NAF splays into two major strands near the west of Bolu city as Northern and Southern strands. Northern strand passes Sapanca Lake and extends towards west and reaches Marmara Sea through the Gulf of Izmit. The area has high seismicity; 1999 Kocaeli (Mw=7.4) and 1999 Düzce (Mw=7.2) earthquakes caused approximately 150 km long surface rupture between the Gulf of Izmit and Bolu. The rupture has four distinct fault segments as Gölcük, Sapanca, Sakarya, and Karadere from west to east. In this study multi-channel seismic and magnetic data are collected for the first time on the Sapanca Segment to investigate the surficial and deeper geometry of the NAF. Previously, the NAF in the eastern Marmara region is investigated using by paleo-seismological data from trenches on the surface rupture of fault or the geomorphological data (Lettis et al., 2000; Dikbaş and Akyüz, 2010) which have shallower depth targets. Crustal structure and seismic velocities for Central Anatolia and eastern Marmara regions are obtained from deeper targeted refraction data (Gürbüz et al., 1992). However, their velocity models do not have the spatial resolution to determine details of the fault zone structure. Multi-channel seismic and magnetic data in this study were acquired on two N-S directed profiles crossing NAF perpendicularly near Kartepe on the western part of the Sapanca Lake in October 2016. The receiver interval is 5 m, shot interval is 5-10 m, and the total length of the profiles are approximately 1400 m. Buffalo Gun is used as a seismic source for deeper penetration. Conventional seismic reflection processing steps are applied to the data. These are geometry definition, editing, filtering, static correction, velocity analysis and deconvolution, stacking and migration. Echos seismic software package in Geophysical Department

  1. The suppression effect of a periodic surface with semicircular grooves on the high power microwave long pill-box window multipactor phenomenon

    Science.gov (United States)

    Zhang, Xue; Wang, Yong; Fan, Junjie; Zhong, Yong; Zhang, Rui

    2014-09-01

    To improve the transmitting power in an S-band klystron, a long pill-box window that has a disk with grooves with a semicircular cross section is theoretically investigated and simulated. A Monte-Carlo algorithm is used to track the secondary electron trajectories and analyze the multipactor scenario in the long pill-box window and on the grooved surface. Extending the height of the long-box window can decrease the normal electric field on the surface of the window disk, but the single surface multipactor still exists. It is confirmed that the window disk with periodic semicircular grooves can explicitly suppress the multipactor and predominantly depresses the local field enhancement and the bottom continuous multipactor. The difference between semicircular and sharp boundary grooves is clarified numerically and analytically.

  2. The suppression effect of a periodic surface with semicircular grooves on the high power microwave long pill-box window multipactor phenomenon

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xue, E-mail: zhangxue.iecas@yahoo.com; Wang, Yong; Fan, Junjie; Zhong, Yong; Zhang, Rui [Institute of Electronics, Chinese Academy of Sciences, Peking, 100190 China (China)

    2014-09-15

    To improve the transmitting power in an S-band klystron, a long pill-box window that has a disk with grooves with a semicircular cross section is theoretically investigated and simulated. A Monte-Carlo algorithm is used to track the secondary electron trajectories and analyze the multipactor scenario in the long pill-box window and on the grooved surface. Extending the height of the long-box window can decrease the normal electric field on the surface of the window disk, but the single surface multipactor still exists. It is confirmed that the window disk with periodic semicircular grooves can explicitly suppress the multipactor and predominantly depresses the local field enhancement and the bottom continuous multipactor. The difference between semicircular and sharp boundary grooves is clarified numerically and analytically.

  3. The suppression effect of a periodic surface with semicircular grooves on the high power microwave long pill-box window multipactor phenomenon

    International Nuclear Information System (INIS)

    Zhang, Xue; Wang, Yong; Fan, Junjie; Zhong, Yong; Zhang, Rui

    2014-01-01

    To improve the transmitting power in an S-band klystron, a long pill-box window that has a disk with grooves with a semicircular cross section is theoretically investigated and simulated. A Monte-Carlo algorithm is used to track the secondary electron trajectories and analyze the multipactor scenario in the long pill-box window and on the grooved surface. Extending the height of the long-box window can decrease the normal electric field on the surface of the window disk, but the single surface multipactor still exists. It is confirmed that the window disk with periodic semicircular grooves can explicitly suppress the multipactor and predominantly depresses the local field enhancement and the bottom continuous multipactor. The difference between semicircular and sharp boundary grooves is clarified numerically and analytically

  4. The study of thermal tunable coupling between a Superconducting photonic crystal waveguide and semi-circular photonic crystal

    Energy Technology Data Exchange (ETDEWEB)

    Oskooi, Somayeh; Barvestani, Jamal, E-mail: barvestani@tabrizu.ac.ir

    2016-08-15

    Highlights: • The light coupling between superconducting photonic crystal waveguide and a semi-circular photonic crystal has been studied. • We utilized the finite difference time domain and plane wave expansion methods in the calculations. • The effect of the size of the nearest neighbor rods of waveguide on the coupling efficiency has been investigated. • The coupling efficiencies are reported versus the temperature of the superconducting waveguide. - Abstract: Through the present study, we investigated the light coupling between superconducting photonic crystal waveguide and a semi-circular photonic crystal. By using the finite difference time domain method, we evaluated the coupling efficiency between the mentioned structures at the various temperatures for different waveguide sizes. Calculation demonstrated that the coupling efficiency strongly depended on the temperature of the superconductor. The peak value of the coupling efficiency was influenced by the size of the nearest neighbor rods of waveguide. The results have shown that it is possible to obtain high efficiency at the desired temperature with proper selection of physical parameters in far-infrared frequency region. This structure has great potential in the optical integration and other areas.

  5. Retention of Root Canal Posts

    DEFF Research Database (Denmark)

    Sahafi, A; Benetti, Ana Raquel; Flury, S

    2015-01-01

    The aim of this study was to investigate the effect of the cement film thickness of a zinc phosphate or a resin cement on retention of untreated and pretreated root canal posts. Prefabricated zirconia posts (CosmoPost: 1.4 mm) and two types of luting cements (a zinc phosphate cement [DeTrey Zinc...... received tribochemical silicate coating according to the manufacturer's instructions. Posts were then luted in the prepared root canals (n=30 per group). Following water storage at 37°C for seven days, retention of the posts was determined by the pull-out method. Irrespective of the luting cement......, pretreatment with tribochemical silicate coating significantly increased retention of the posts. Increased cement film thickness resulted in decreased retention of untreated posts and of pretreated posts luted with zinc phosphate cement. Increased cement film thickness had no influence on retention...

  6. Mapping of calf muscle oxygenation and haemoglobin content during dynamic plantar flexion exercise by multi-channel time-resolved near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Torricelli, Alessandro; Quaresima, Valentina; Pifferi, Antonio; Biscotti, Giovanni; Spinelli, Lorenzo; Taroni, Paola; Ferrari, Marco; Cubeddu, Rinaldo

    2004-01-01

    A compact and fast multi-channel time-resolved near-infrared spectroscopy system for tissue oximetry was developed. It employs semiconductor laser and fibre optics for delivery of optical signals. Photons are collected by eight 1 mm fibres and detected by a multianode photomultiplier. A time-correlated single photon counting board is used for the parallel acquisition of time-resolved reflectance curves. Estimate of the reduced scattering coefficient is achieved by fitting with a standard model of diffusion theory, while the modified Lambert-Beer law is used to assess the absorption coefficient. In vivo measurements were performed on five healthy volunteers to monitor spatial changes in calf muscle (medial and lateral gastrocnemius; MG, LG) oxygen saturation (SmO 2 ) and total haemoglobin concentration (tHb) during dynamic plantar flexion exercise performed at 50% of the maximal voluntary contraction. At rest SmO 2 was 73.0 ± 0.9 and 70.5 ± 1.7% in MG and LG, respectively (P = 0.045). At the end of the exercise, SmO 2 decreased (69.1 ± 1.8 and 63.8 ± 2.1% in MG and LG, respectively; P 2 and tHb

  7. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  8. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.

    Science.gov (United States)

    Komorowski, Dariusz; Pietraszek, Stanislaw

    2016-01-01

    This paper presents the analysis of multi-channel electrogastrographic (EGG) signals using the continuous wavelet transform based on the fast Fourier transform (CWTFT). The EGG analysis was based on the determination of the several signal parameters such as dominant frequency (DF), dominant power (DP) and index of normogastria (NI). The use of continuous wavelet transform (CWT) allows for better visible localization of the frequency components in the analyzed signals, than commonly used short-time Fourier transform (STFT). Such an analysis is possible by means of a variable width window, which corresponds to the scale time of observation (analysis). Wavelet analysis allows using long time windows when we need more precise low-frequency information, and shorter when we need high frequency information. Since the classic CWT transform requires considerable computing power and time, especially while applying it to the analysis of long signals, the authors used the CWT analysis based on the fast Fourier transform (FFT). The CWT was obtained using properties of the circular convolution to improve the speed of calculation. This method allows to obtain results for relatively long records of EGG in a fairly short time, much faster than using the classical methods based on running spectrum analysis (RSA). In this study authors indicate the possibility of a parametric analysis of EGG signals using continuous wavelet transform which is the completely new solution. The results obtained with the described method are shown in the example of an analysis of four-channel EGG recordings, performed for a non-caloric meal.

  9. Imaging observations of nighttime mid-latitude F-region field-aligned irregularities by an MU radar ultra-multi-channel system

    Directory of Open Access Journals (Sweden)

    S. Saito

    2008-08-01

    Full Text Available Mid-latitude F-region field-aligned irregularities (FAIs were studied by using the middle-and-upper atmosphere (MU radar ultra-multi-channel system with the radar imaging technique. On 12 June 2006, F-region FAI echoes with a period of about one hour were observed intermittently. These echoes were found to be embedded in medium-scale traveling ionospheric disturbances (MSTIDs observed as variations of total electron content (TEC. The echoes drifting away from (toward the radar were observed in the depletion (enhancement phase of the MSTID. The Doppler velocity of the echoes is consistent with the range rates in the the range-time-intensity (RTI maps. Fine scale structures with a spatial scale of 10 km or less were found by the radar imaging analysis. Those structures with positive Doppler velocities (moving away from the radar appeared to drift north- (up- westward, and those with negative Doppler velocities south- (down- eastward approximately along the wavefronts of the MSTID. FAIs with positive Doppler velocities filling TEC depletion regions were observed.

  10. The EarthScope Array Network Facility: application-driven low-latency web-based tools for accessing high-resolution multi-channel waveform data

    Science.gov (United States)

    Newman, R. L.; Lindquist, K. G.; Clemesha, A.; Vernon, F. L.

    2008-12-01

    Since April 2004 the EarthScope USArray seismic network has grown to over 400 broadband stations that stream multi-channel data in near real-time to the Array Network Facility in San Diego. Providing secure, yet open, access to real-time and archived data for a broad range of audiences is best served by a series of platform agnostic low-latency web-based applications. We present a framework of tools that interface between the world wide web and Boulder Real Time Technologies Antelope Environmental Monitoring System data acquisition and archival software. These tools provide audiences ranging from network operators and geoscience researchers, to funding agencies and the general public, with comprehensive information about the experiment. This ranges from network-wide to station-specific metadata, state-of-health metrics, event detection rates, archival data and dynamic report generation over a stations two year life span. Leveraging open source web-site development frameworks for both the server side (Perl, Python and PHP) and client-side (Flickr, Google Maps/Earth and jQuery) facilitates the development of a robust extensible architecture that can be tailored on a per-user basis, with rapid prototyping and development that adheres to web-standards.

  11. Segmentation and profiling consumers in a multi-channel environment using a combination of self-organizing maps (SOM method, and logistic regression

    Directory of Open Access Journals (Sweden)

    Seyed Ali Akbar Afjeh

    2014-05-01

    Full Text Available Market segmentation plays essential role on understanding the behavior of people’s interests in purchasing various products and services through various channels. This paper presents an empirical investigation to shed light on consumer’s purchasing attitude as well as gathering information in multi-channel environment. The proposed study of this paper designed a questionnaire and distributed it among 800 people who were at least 18 years of age and had some experiences on purchasing goods and services on internet, catalog or regular shopping centers. Self-organizing map, SOM, clustering technique was performed based on consumer’s interest in gathering information as well as purchasing products through internet, catalog and shopping centers and determined four segments. There were two types of questions for the proposed study of this paper. The first group considered participants’ personal characteristics such as age, gender, income, etc. The second group of questions was associated with participants’ psychographic characteristics including price consciousness, quality consciousness, time pressure, etc. Using multinominal logistic regression technique, the study determines consumers’ behaviors in each four segments.

  12. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Durand, Marie-Jose; Jouanneau, Sulivan; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Dion, Michel [UMR CNRS 6204, Nantes University, PRES UNAM, Biotechnologie, Biocatalyse, Bioregulation, 2, Rue de la Houssiniere, BP 92208, Nantes cedex 3 (France); Pernetti, Mimma; Poncelet, Denis [ONIRIS-ENITIAA, UMR CNRS GEPEA, Rue de la Geraudiere, BP 82225, Nantes cedex 3 (France)

    2011-05-15

    This study describes the construction of inducible bioluminescent strains via genetic engineering along with their characterization and optimization in the detection of heavy metals. Firstly, a preliminary comparative study enabled us to select a suitable carbon substrate from pyruvate, glucose, citrate, diluted Luria-Bertani, and acetate. The latter carbon source provided the best induction ratios for comparison. Results showed that the three constructed inducible strains, Escherichia coli DH1 pBzntlux, pBarslux, and pBcoplux, were usable when conducting a bioassay after a 14-h overnight culture at 30 C. Utilizing these sensors gave a range of 12 detected heavy metals including several cross-detections. Detection limits for each metal were often close to and sometimes lower than the European standards for water pollution. Finally, in order to maintain sensitive bacteria within the future biosensor-measuring cell, the agarose immobilization matrix was compared to polyvinyl alcohol (PVA). Agarose was selected because the detection limits of the bioluminescent strains were not affected, in contrast to PVA. Specific detection and cross-detection ranges determined in this study will form the basis of a multiple metals detection system by the new multi-channel Lumisens3 biosensor. (orig.)

  13. Biodegradation of a commercial mixture of the herbicides atrazine and S-metolachlor in a multi-channel packed biofilm reactor.

    Science.gov (United States)

    Cabrera-Orozco, Alberto; Galíndez-Nájera, Silvia Patricia; Ruiz-Ordaz, Nora; Galíndez-Mayer, Juvencio; Martínez-Jerónimo, Fernando

    2017-11-01

    Atrazine and S-metolachlor are two of the most widely used herbicides for agricultural purposes; consequently, residues of both compounds and their metabolites had been detected in ground and superficial waters. Unlike atrazine, the complete degradation of metolachlor has not been achieved. Hence, the purpose of this research is to study the biodegradation of a commercial mixture of atrazine and S-metolachlor in a prototype of a multi-channel packed-bed-biofilm reactor (MC-PBR) designed with the aim of solving the problems of pressure drop and oxygen transfer, typically found on this type of bioreactors.Because the removal efficiency of the herbicides was increased when Candida tropicalis was added to the original microbial community isolated, the reactor was inoculated with this enriched community. The operational conditions tested in batch and continuous mode did not affect the removal efficiency of atrazine; however, this was not the case for S-metolachlor. The removal rates and efficiencies showed a notable variation along the MC-PBR operation.

  14. 12.5 Gb/s multi-channel broadcasting transmission for free-space optical communication based on the optical frequency comb module.

    Science.gov (United States)

    Tan, Jun; Zhao, Zeping; Wang, Yuehui; Zhang, Zhike; Liu, Jianguo; Zhu, Ninghua

    2018-01-22

    A wide-spectrum, ultra-stable optical frequency comb (OFC) module with 100 GHz frequency intervals based on a quantum dot mode locked (QDML) laser is fabricated by our lab, and a scheme with 12.5 Gb/s multi-channel broadcasting transmission for free-space optical (FSO) communication is proposed based on the OFC module. The output power of the OFC is very stable, with the specially designed circuit and the flatness of the frequency comb over the span of 6 nm, which can be limited to 1.5 dB. Four channel wavelengths are chosen to demonstrate one-to-many channels for FSO communication, like optical wireless broadcast. The outdoor experiment is established to test the bit error rate (BER) and eye diagrams with 12.5 Gb/s on-off keying (OOK). The indoor experiment is used to test the highest traffic rate, which is up to 21 Gb/s for one-hop FSO communication. To the best of our knowledge, this scheme is the first to propose the realization of one-to-many broadcasting transmission for FSO communication based on the OFC module. The advantages of integration, miniaturization, channelization, low power consumption, and unlimited bandwidth of one-to-many broadcasting communication scheme, shows promising results on constructing the future space-air-ground-ocean (SAGO) FSO communication networks.

  15. The design of the layout of faceted multi-channel electro-optical spatial coordinates measuring instrument for point-like bright objects

    Science.gov (United States)

    Repin, Vladislav A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2017-06-01

    For many applied problems it is necessary to obtain information about the situation in a wide angular field in order to measure various parameters of objects: their spatial coordinates, instantaneous velocities, and so on. In this case, one interesting bionic approach can be used - a mosaic (or discrete, otherwise, facet) angular field. Such electro-optical system constructively imitates the visual apparatus of insects: many photodetectors like ommatidia (elements of the facet eye structure) are located on a non-planar surface. Such devices can be used in photogrammetry and aerial photography systems (if the space is sufficient), in the transport sector as vehicle orientation organs, as systems for monitoring in unmanned aerial vehicles, in endoscopy for obtaining comprehensive information on the state of various cavities, in intelligent robotic systems. In this manuscript discusses the advantages and disadvantages of multi-channeled optoelectronic systems with a mosaic angular field, presents possible options for their use, and discusses some of the design procedures performed when developing a layout of a coordinate measuring device.

  16. Scalloping at the lumbosacral canal

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, R.

    1987-07-01

    Scalloping is an indentation of the dorsal side of the vertebral body (anterior wall of the lumbosacral or sacral canal) which typically involves several adjacent lumbal vertebral body segments and the anterior wall of the canalis sacralis. Occurrence without underlying disease is rare; it occurs most frequently with chondrodystrophy, neurofibromatosis, Morquio's syndrome, Hurler's syndrome, acromegaly, Ehlers-Danlos syndrome, Marfan's syndrome, cysts, tumors and in peridural lipomas.

  17. Scalloping at the lumbosacral canal

    International Nuclear Information System (INIS)

    Reinhardt, R.

    1987-01-01

    Scalloping is an indentation of the dorsal side of the vertebral body (anterior wall of the lumbosacral or sacral canal) which typically involves several adjacent lumbal vertebral body segments and the anterior wall of the canalis sacralis. Occurrence without underlying disease is rare; it occurs most frequently with chondrodystrophy, neurofibromatosis, Morquio's syndrome, Hurler's syndrome, acromegaly, Ehlers-Danlos syndrome, Marfan's syndrome, cysts, tumors and in peridural lipomas. (orig.) [de

  18. Hydrocele of the canal of Nuck

    Directory of Open Access Journals (Sweden)

    Nourah ALSaleh

    2018-02-01

    Full Text Available Hydrocele of the canal of Nuck is a rare condition in female children caused by a failure of complete obliteration of the canal of Nuck. The canal of Nuck is an abnormal patent pouch of the peritoneum extending anterior to the round ligament of the uterus into the labia majora. Incomplete obliteration of this canal (patent processus vaginalis can result in either an inguinal hernia or a hydrocele. Here, we report two cases of hydrocele of the canal of Nuck presented within a two-month period. In the first case, incarcerated right-sided inguinal hernia was suspected while the second case was clinically diagnosed as encysted hydrocele of canal of Nuck. Both patients underwent surgical exploration. Hydrocelectomy with high ligation was also performed. One month after the surgery, the first patient showed signs of hydrocele on contralateral side, while the other patient showed no sign of contralateral hydrocele or hernia.

  19. Stability of guest molecules in urea canal complexes by canal polymerization

    International Nuclear Information System (INIS)

    Yoshii, Fumio; Makuuchi, Keizo

    1995-01-01

    It was found that various organic materials are attracted into urea canal by hexanediol diacrylate (HDDA) and long chain compounds. This means that materials which does not form complex by itself are induced in canal by HDDA and long chain compounds. To include with stability perfumes, insecticides, attractants and repellents in urea canal, leaf alcohol was used as a model compound for guest molecules in the canal. The leaf alcohol from the canal released gradually over many days and the release was inhibited for 15 days by long chain compounds and for 30 days by polymerized HDDA after irradiation. After releasing, the leaf alcohol in the canal remained 25 % stable for long chain compounds and 40 % for polymerized HDDA. The dose required for stabilization of leaf alcohol in the urea canal by canal polymerization of HDDA was 30 kGy. (author)

  20. [Root canal treatment of mandibular first premolar with 4 root canals: a case report].

    Science.gov (United States)

    Liu, Xin-yang; Zhan, Fu-Liang

    2015-10-01

    The mandibular first premolar can be considered one of the most challenging teeth to treat, due to the complexity of its root canal morphology and increased incidence of multiple canals. A case of endodontic treatment of a mandibular first premolar exhibiting a total of 4 distinct root canals and 4 apical foramina was described. Anatomic variation of root canal morphology should be considered in endodontic treatment to ensure a favorable healing outcome, and its identification could be enhanced by careful examination using a dental operating microscope. Obturation of root canals using a warm vertical compaction technique with a highly-radiopaque root canal sealer, such as AH Plus, after careful ultrasonic activated irrigation might allow the flow of sealer into the narrowed but unprepared part of the canal, thereby facilitating optimum chemo-mechanical debridement of the root canal system.

  1. SCOTCH: a program for solution of the one-dimensional, two-group, space-time neutron diffusion equations with temperature feedback of multi-channel fluid dynamics for HTGR cores

    International Nuclear Information System (INIS)

    Ezaki, Masahiro; Mitake, Susumu; Ozawa, Tamotsu

    1979-06-01

    The SCOTCH program solves the one-dimensional (R or Z), two-group reactor kinetics equations with multi-channel temperature transients and fluid dynamics. Sub-program SCOTCH-RX simulates the space-time neutron diffusion in radial direction, and sub-program SCOTCH-AX simulates the same in axial direction. The program has about 8,000 steps of FORTRAN statement and requires about 102 kilo-words of computer memory. (author)

  2. Effect of the Presence of Semi-circular Cylinders on Heat Transfer From Heat Sources Placed in Two Dimensional Channel

    Directory of Open Access Journals (Sweden)

    Ahmed W. Mustava

    2013-04-01

    Full Text Available The effect of a semi-circular cylinders in a two dimensional channel on heat transfer by forced convection from two heat sources with a constant temperature has been studied numerically. Each channel contains two heat sources; one on the upper surface of the channel and the other on the lower surface of the channel. There is semi-circular cylinder under the source in upper surface and there is semi-circular cylinder above the source in lower surface. The location of the second heat source with its semi-cylinder has been changed and keeps the first source with its semi- cylinder at the same location. The flow and temperature field are studied numerically with different values of Reynolds numbers and for different spacing between the centers of the semi-cylinders. The laminar flow field is analyzed numerically by solving the steady forms of the two-dimensional incompressible Navier- Stokes and energy equations.  The Cartesian velocity components and pressure on a collocated (non-staggered grid are used as dependent variables in the momentum equations, which discretized by finite volume method, body fitted coordinates are used to represent the complex channel geometry accurately, and grid generation technique based on elliptic partial differential equations is employed. SIMPLE algorithm is used to adjust the velocity field to satisfy the conservation of mass.  The range of Reynolds number is (Re= 100 – 800 and the range of the spacing between the semi-cylinders is(1-4 and the Prandtl number is 0.7.The results showed that increasing the spacing between the semi-cylinders increases the average of Nusselt number of the first heat source for all Reynolds numbers. As well as the results show that the best case among the cases studied to enhance the heat transfer is when the second heat source and its semi-cylinder located on at the distance (S=1.5 from the first half of the cylinder and the Reynolds number is greater than (Re ≥ 400 because of the

  3. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  4. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Chapeau, Cyrille [Biolumine, Biokar Diagnostic, Rue des Quarante Mines ZAC de Ther-Allonne, Beauvais Cedex (France); Bendria, Loubna; Daniel, Philippe [UMR CNRS 6087 LPEC, Universite du Maine, Av Olivier Messiaen, Le Mans cedex 9 (France); Picart, Pascal [UMR CNRS 6613 IAM-LAUM, Ecole Nationale des Ingenieurs du Mans, Universite du Maine, Le Mans Cedex 9 (France)

    2011-05-15

    This research study deals with the on-line detection of heavy metals and toxicity within the context of environmental pollution monitoring. It describes the construction and the proof of concept of a multi-channel bioluminescent bacterial biosensor in immobilized phase: Lumisens3. This new versatile device, designed for the non-stop analysis of water pollution, enables the insertion of any bioluminescent strains (inducible or constitutive), immobilized in a multi-well removable card. The technical design of Lumisens3 has benefited from both a classical and a robust approach and includes four main parts: (1) a dedicated removable card contains 64 wells, 3 mm in depth, arranged in eight grooves within which bacteria are immobilized, (2) this card is incubated on a Pelletier block with a CCD cooled camera on top for bioluminescence monitoring, (3) a fluidic network feeds the card with the sample to be analyzed and finally (4) a dedicated computer interface, BIOLUX 1.0, controls all the elements of the biosensor, allowing it to operate autonomously. The proof of concept of this biosensor was performed using a set of four bioluminescent bacteria (Escherichia coli DH1 pBzntlux, pBarslux, pBcoplux, and E. coli XL1 pBfiluxCDABE) in the on-line detection of CdCl{sub 2} 0.5 {mu}M and As{sub 2}O{sub 3} 5 {mu}M from an influent. When considering metals individually, the ''fingerprints'' from the biosensor were as expected. However, when metals were mixed together, cross reaction and synergistic effects were detected. This biosensor allowed us to demonstrate the simultaneous on-line cross detection of one or several heavy metals as well as the measurement of the overall toxicity of the sample. (orig.)

  5. Acquisition and preliminary analysis of multi-channel seismic reflection data, acquired during the oceanographic cruises of the TOMO-ETNA experiment

    Directory of Open Access Journals (Sweden)

    Marco Firetto Carlino

    2016-09-01

    Full Text Available The TOMO-ETNA experiment was performed in the framework of the FP7 “MED-SUV” (MEDiterranean SUpersite Volcanoes in order to gain a detailed geological and structural model of the continental and oceanic crust concerning Etna and Aeolian Islands volcanoes (Sicily, Italy, by means of active and passive seismic exploration methodologies. Among all data collected, some 1410 km of marine multi-channel seismic (MCS reflection profiles were acquired in the Ionian and Tyrrhenian Seas during two of the three oceanographic cruises of the TOMO-ETNA experiment, in July and November 2014, with the aim of shading light to deep, intermediate and shallow stratigraphy and crustal structure of the two above mentioned areas. The MCS sections, targeted to deep exploration, were acquired during the oceanographic cruise on board the R/V “Sarmiento de Gamboa”, using an active seismic source of 16 air-guns, for a total volume of 4340 cu. in., and a 3000 m long, 240-channels digital streamer as receiving system. High-resolution seismic profiles were instead collected through the R/V “Aegaeo”, using two smaller air-guns (overall 270 cu. in. volume and a 96 channels, 300 m long digital streamer. This paper provides a detailed description of the acquisition parameters and main processing steps adopted for the MCS data. Some processed lines are shown and preliminarily interpreted, to highlight the overall good quality and the high potential of the MCS sections collected during the TOMO-ETNA experiment.

  6. Surface morphology and surface energy of anode materials influence power outputs in a multi-channel mediatorless bio-photovoltaic (BPV) system.

    Science.gov (United States)

    Bombelli, Paolo; Zarrouati, Marie; Thorne, Rebecca J; Schneider, Kenneth; Rowden, Stephen J L; Ali, Akin; Yunus, Kamran; Cameron, Petra J; Fisher, Adrian C; Ian Wilson, D; Howe, Christopher J; McCormick, Alistair J

    2012-09-21

    Bio-photovoltaic cells (BPVs) are a new photo-bio-electrochemical technology for harnessing solar energy using the photosynthetic activity of autotrophic organisms. Currently power outputs from BPVs are generally low and suffer from low efficiencies. However, a better understanding of the electrochemical interactions between the microbes and conductive materials will be likely to lead to increased power yields. In the current study, the fresh-water, filamentous cyanobacterium Pseudanabaena limnetica (also known as Oscillatoria limnetica) was investigated for exoelectrogenic activity. Biofilms of P. limnetica showed a significant photo response during light-dark cycling in BPVs under mediatorless conditions. A multi-channel BPV device was developed to compare quantitatively the performance of photosynthetic biofilms of this species using a variety of different anodic conductive materials: indium tin oxide-coated polyethylene terephthalate (ITO), stainless steel (SS), glass coated with a conductive polymer (PANI), and carbon paper (CP). Although biofilm growth rates were generally comparable on all materials tested, the amplitude of the photo response and achievable maximum power outputs were significantly different. ITO and SS demonstrated the largest photo responses, whereas CP showed the lowest power outputs under both light and dark conditions. Furthermore, differences in the ratios of light : dark power outputs indicated that the electrochemical interactions between photosynthetic microbes and the anode may differ under light and dark conditions depending on the anodic material used. Comparisons between BPV performances and material characteristics revealed that surface roughness and surface energy, particularly the ratio of non-polar to polar interactions (the CQ ratio), may be more important than available surface area in determining biocompatibility and maximum power outputs in microbial electrochemical systems. Notably, CP was readily outperformed by all

  7. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    Science.gov (United States)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  8. Narrow, duplicated internal auditory canal

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, T. [Servico de Neurorradiologia, Hospital Garcia de Orta, Avenida Torrado da Silva, 2801-951, Almada (Portugal); Shayestehfar, B. [Department of Radiology, UCLA Oliveview School of Medicine, Los Angeles, California (United States); Lufkin, R. [Department of Radiology, UCLA School of Medicine, Los Angeles, California (United States)

    2003-05-01

    A narrow internal auditory canal (IAC) constitutes a relative contraindication to cochlear implantation because it is associated with aplasia or hypoplasia of the vestibulocochlear nerve or its cochlear branch. We report an unusual case of a narrow, duplicated IAC, divided by a bony septum into a superior relatively large portion and an inferior stenotic portion, in which we could identify only the facial nerve. This case adds support to the association between a narrow IAC and aplasia or hypoplasia of the vestibulocochlear nerve. The normal facial nerve argues against the hypothesis that the narrow IAC is the result of a primary bony defect which inhibits the growth of the vestibulocochlear nerve. (orig.)

  9. Oralidad en el Canal Pimp Placo

    OpenAIRE

    Miguel Espigado

    2017-01-01

    Pimp Flaco, a trap artist from Barcelona, and his thousands of fans that follow his public profiles in Instagram and Twitter and Youtube, have created a multi-channel of complex orality where art reception and art work become one. Artist and followers’ messages mix art and comunication, up to the point of culture stopping to be a code separated of ordinary communication, and it’s used as a whole by the community for reelaborate and obtain its collective codes. Pimp Flaco, as Homero did, is no...

  10. Some History and Hydrology of the Panama Canal

    National Research Council Canada - National Science Library

    Pabst, Arthur

    2000-01-01

    At the request of the Panama Canal Commission (now Panama Canal Authority), the Hydrologic Engineering Center participated in the development of a model to simulate the existing operation of the Panama Canal System...

  11. Visualizing multi-channel networks

    DEFF Research Database (Denmark)

    Antemijczuk, Paweł; Magiera, Marta; Jørgensen, Sune Lehmann

    2014-01-01

    In this paper, we propose a visualization to illustrate social interactions, built from multiple distinct channels of communication. The visualization displays a summary of dense personal information in a compact graphical notation. The starting point is an abstract drawing of a spider’s web. Below...

  12. About ecological aspects of "Eurasia" canal construction

    Directory of Open Access Journals (Sweden)

    G. M. Abdurakhmanov

    2010-01-01

    Full Text Available Ecological aspects of "Eurasia" canal construction are considered here. The fact that can negatively affect natural area preservation (preserves, reserves, located in Kumo-Manych depression, along where the canal construction will take place, is shown in this article.

  13. [Upper lateral incisor with 2 canals].

    Science.gov (United States)

    Fabra Campos, H

    1991-01-01

    Clinical case summary of the patient with an upper lateral incisor with two root canals. The suspicion that there might be an anatomic anomaly in the root that includes a complex root canal system was made when an advanced radicular groove was detected in the lingual surface or an excessively enlarged cingulum.

  14. Neuronal hyperplasia in the anal canal

    DEFF Research Database (Denmark)

    Fenger, C; Schrøder, H D

    1990-01-01

    In a consecutive series of minor surgical specimens from the anal canal, neuronal hyperplasia was found in nine of 56 haemorrhoidectomy specimens and in four of 23 fibrous polyps. In an additional series of 14 resections of the anal canal, neuronal hyperplasia was present in six cases, of which f...

  15. Bilateral duplication of the internal auditory canal

    International Nuclear Information System (INIS)

    Weon, Young Cheol; Kim, Jae Hyoung; Choi, Sung Kyu; Koo, Ja-Won

    2007-01-01

    Duplication of the internal auditory canal is an extremely rare temporal bone anomaly that is believed to result from aplasia or hypoplasia of the vestibulocochlear nerve. We report bilateral duplication of the internal auditory canal in a 28-month-old boy with developmental delay and sensorineural hearing loss. (orig.)

  16. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  17. Type III apical transportation of root canal

    Directory of Open Access Journals (Sweden)

    Shiv P Mantri

    2012-01-01

    Full Text Available Procedural accidents leading to complications such as canal transportation have been ascribed to inapt cleaning and shaping concepts. Canal transportation is an undesirable deviation from the natural canal path. Herewith a case of apical transportation of root canal resulting in endodontic retreatment failure and its management is presented. A healthy 21-year-old young male presented discomfort and swelling associated with painful endodontically retreated maxillary incisor. Radiograph revealed periradicular radiolucency involving underfilled 11 and overfilled 12. Insufficiently obturated 11 exhibited apical transportation of canal. This type III transportation was treated by periradicular surgery and repair using white mineral trioxide aggregate (MTA. Comfortable asymptomatic patient presented uneventful healing at third and fourth month recall visits. A decrease in the size of radiolucency in radiograph supported the clinical finding. In the present case, MTA is useful in repairing the transportation defect. The result of these procedures is predictable and successful.

  18. Microbiological examination of infected dental root canals.

    Science.gov (United States)

    Gomes, B P F A; Pinheiro, E T; Gadê-Neto, C R; Sousa, E L R; Ferraz, C C R; Zaia, A A; Teixeira, F B; Souza-Filho, F J

    2004-04-01

    The aim of this study was to investigate the root canal microbiota of primary and secondary root-infected canals and the association of constituent species with specific endodontic signs and symptoms. Microbial samples were taken from 60 root canals, 41 with necrotic pulp tissues (primary infection) and 19 with failed endodontic treatment (secondary infection). Strict anaerobic techniques were used for serial dilution, plating, incubation and identification. A total of 224 cultivable isolates were recovered belonging to 56 different bacterial species. Individual root canals yielded a maximum of 10 bacterial species. Of the bacterial isolates, 70% were either strict anaerobes or microphilic. The anaerobes most frequently isolated were: Peptostreptococcus micros (35%), Fusobacterium necrophorum (23.3%), Fusobacterium nucleatum (11.7%), Prevotella intermedia/nigrescens (16.7%), Porphyromonas gingivalis (6.7%) and Porphyromonas endodontalis (5%). The root canal microflora of untreated teeth with apical periodontitis was found to be mixed, comprising gram-negative and gram-positive and mostly anaerobic microorganisms and usually containing more than 3 species per canal. On the other hand, facultative anaerobic and gram-positive bacteria predominated in canals with failed endodontic treatment, which harbored 1-2 species per canal. Suggested relationships were found between anaerobes, especially gram-negatives, and the presence or history of pain, tenderness to percussion and swelling (PEubacterium spp. (both Pspp. (Pspp. (Pspp. (Pspp. (Pspp. (Pspp. (Pspp. (Pspp., P. micros, F. necrophorum (P<0.05). Our findings indicate potential complex interactions of species resulting in characteristic clinical pictures which cannot be achieved by individual species alone. They also indicate that the microbiota of primary infected canals with apical periodontitis differs in number and in species from the secondary infected canals by using the culture technique.

  19. The effects of betahistine in addition to epley maneuver in posterior canal benign paroxysmal positional vertigo.

    Science.gov (United States)

    Guneri, Enis Alpin; Kustutan, Ozge

    2012-01-01

    The purpose of this study is to evaluate the effects of betahistine in addition to Epley maneuver on the quality of life of patients with posterior semicircular canal benign paroxysmal positional vertigo (BPPV) of the canalithiasis type. Double-blind, randomized, controlled clinical trial. Academic university hospital. Seventy-two patients were enrolled in the study. The first group was treated with Epley maneuver only. The second group received placebo drug 2 times daily for 1 week in addition to Epley maneuver, and the third group received 24 mg betahistine 2 times daily for 1 week in addition to Epley maneuver. The effectiveness of the treatments was assessed in each group as well as between them by analyzing and comparing data of 4 different vertigo symptom scales. Epley maneuver, alone or combined with betahistine or placebo, was found to be very effective with a primary success rate of 86.2%. The symptoms were significantly reduced in group 3 patients overall, and those patients younger or older than 50 years of age who had hypertension, with symptom onset <1 month, and with attack duration of less than a minute did significantly better with the combination of betahistine 48 mg daily. Betahistine in addition to Epley maneuver is more effective than Epley maneuver alone or combined with placebo with regard to improvement of symptoms in certain patients. However, future clinical studies covering more patients to investigate the benefit of medical treatments in addition to Epley maneuver are needed.

  20. Detection of gear cracks in a complex gearbox of wind turbines using supervised bounded component analysis of vibration signals collected from multi-channel sensors

    Science.gov (United States)

    Li, Zhixiong; Yan, Xinping; Wang, Xuping; Peng, Zhongxiao

    2016-06-01

    In the complex gear transmission systems, in wind turbines a crack is one of the most common failure modes and can be fatal to the wind turbine power systems. A single sensor may suffer with issues relating to its installation position and direction, resulting in the collection of weak dynamic responses of the cracked gear. A multi-channel sensor system is hence applied in the signal acquisition and the blind source separation (BSS) technologies are employed to optimally process the information collected from multiple sensors. However, literature review finds that most of the BSS based fault detectors did not address the dependence/correlation between different moving components in the gear systems; particularly, the popular used independent component analysis (ICA) assumes mutual independence of different vibration sources. The fault detection performance may be significantly influenced by the dependence/correlation between vibration sources. In order to address this issue, this paper presents a new method based on the supervised order tracking bounded component analysis (SOTBCA) for gear crack detection in wind turbines. The bounded component analysis (BCA) is a state of art technology for dependent source separation and is applied limitedly to communication signals. To make it applicable for vibration analysis, in this work, the order tracking has been appropriately incorporated into the BCA framework to eliminate the noise and disturbance signal components. Then an autoregressive (AR) model built with prior knowledge about the crack fault is employed to supervise the reconstruction of the crack vibration source signature. The SOTBCA only outputs one source signal that has the closest distance with the AR model. Owing to the dependence tolerance ability of the BCA framework, interfering vibration sources that are dependent/correlated with the crack vibration source could be recognized by the SOTBCA, and hence, only useful fault information could be preserved in

  1. Acceleration induced water removal from ear canals.

    Science.gov (United States)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  2. Clinical significance of dental root canal microflora.

    Science.gov (United States)

    Gomes, B P; Lilley, J D; Drucker, D B

    1996-01-01

    Previous work by this group has shown that a significant association exists between pain and the presence of either Prevotella or Peptostreptococcus spp. in dental root canals. The aim of this study was to examine a more extensive series of canals microbiologically, to determine whether any other particular endodontic symptoms or clinical signs showed specific associations with individual bacterial species. Seventy root canals were examined microbiologically and clinical data collected to investigate in detail such associations. Of the canals studied, 37 were associated with pain, 49 with tenderness to percussion, 23 with swelling, six with purulent exudate and 57 presented with wet root canals. Anaerobes were isolated from 70.3% of painful canals and from 29.7% of pain-free canals. Significant associations were found between (a) pain and either Prevotella spp. or peptostreptococci, both with P spp. (P Eubacterium spp. (P spp. or Pstr. micros, both with P spp. (each P Eubacterium, Peptostreptococcus, Prevotella or Propionibacterium (each P < 0.05). It was concluded that several different endodontic clinical signs and symptoms are significantly associated with specific bacterial species.

  3. Mandibular molar with five root canals.

    Science.gov (United States)

    Barletta, Fernando Branco; Dotto, Sidney Ricardo; Reis, Magda de Sousa; Ferreira, Ronise; Travassos, Rosana Maria Coelho

    2008-12-01

    The purpose of this study was to demonstrate the importance of knowledge of the internal anatomy of root canals for the success of endodontic treatment. Lack of knowledge of anatomic variations and their characteristics in different teeth has been pointed out as one of the main causes of endodontic therapy failure. In this report, the authors describe the endodontic treatment of a mandibular first molar with five root canals, evaluate the rate of occurrence of this number of canals, and discuss the importance of their identification and treatment.

  4. 21 CFR 872.3810 - Root canal post.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal post. 872.3810 Section 872.3810 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3810 Root canal post. (a) Identification. A root canal... of the platinum group intended to be cemented into the root canal of a tooth to stabilize and support...

  5. Assessment of periapical health, quality of root canal filling, and ...

    African Journals Online (AJOL)

    Sixty three teeth were found to have short root canal fillings, whereas 74 teeth had adequate root canal fillings, and the remaining 10 teeth had over extended root canal filling. A significant correlation was observed between the length of root filling and apical periodontitis (P = 0,023). Inadequately dense root canal filling was ...

  6. Condutas pós-manobra de Epley em idosos com VPPB de canal posterior Conduct after Epley's maneuver in elderly with posterior canal BPPV in the posterior canal

    Directory of Open Access Journals (Sweden)

    Ana Paula do Rego André

    2010-06-01

    Full Text Available A Vertigem Postural Paroxística Benigna é a mais comum das vestibulopatias periféricas, principalmente em idosos e apresenta como etiologia predominante nessa população à degeneração da mácula utricular. OBJETIVO: Comparar a eficácia das condutas pós-manobra de Epley. Desenho do Estudo: Estudo de coorte contemporâneo longitudinal. MATERIAL E MÉTODO: Participaram do estudo 53 voluntários com Vertigem Postural Paroxística Benigna de canal semicircular posterior, distribuídos em Grupo 1, submetidos à manobra de Epley associada ao uso do colar cervical e orientações pós-manobra; Grupo 2 submetido a manobra de Epley sem uso do colar cervical e/ou restrições pós-manobra, e Grupo 3 submetido à manobra de Epley associada com o uso de um minivibrador, sem uso de colar cervical e/ou restrições pós-manobra. RESULTADOS: Nos três grupos, o número de manobras de Epley variou de uma a três. Aplicou-se o Dizziness Handicap Inventory brasileiro pré e pós-tratamento e observou-se diferença estatisticamente significativa na maioria dos escores pré e pós-tratamento para os grupos avaliados. CONCLUSÃO: Independentemente da conduta pós-manobra de Epley selecionada para o tratamento da Vertigem Postural Paroxística Benigna, essa se mostrou eficaz quando se comparou o Dizziness Handicap Inventory brasileiro pré e pós-tratamento.Benign Paroxysmal Positional Vertigo is the most common peripheral vestibular disorder, especially in the elderly and presents as the predominant etiology in this population of the degeneration of the utricular macula. AIM: To compare the effectiveness of the approaches after Epley maneuver. Study Design: longitudinal cohort. MATERIALS AND METHODS: The study included 53 volunteers with Benign Paroxysmal Positional Vertigo of the posterior semicircular canal, divided into Group 1, who underwent Epley maneuver associated with the use of neck collar and post-maneuver instructions, Group 2 underwent the Epley

  7. Scanning electron microscopy investigation of canal cleaning after canal preparation with nickel titanium files

    Directory of Open Access Journals (Sweden)

    Živković Slavoljub

    2010-01-01

    Full Text Available Introduction. Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed and safety of the preparation procedure. Objective. The aim of this research was to investigate the influence of different NiTi files on the canal wall cleaning quality, residual dentine debris and smear layer. Methods. The research was conducted on extracted human teeth in vitro conditions. Teeth were divided in 7 main groups depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper and hand GT. Root canal preparation was accomplished by crown-down technique. Prepared samples were assessed on scanning electron microscopy JEOL, JSM-6460 LV. The evaluation of dentine debris was done with 500x magnification, and the evaluation of smear layer with 1,000 times magnification. Quantitive assessment of dentine debris and smear layer was done according to the criteria of Hulsmann. Results. The least amount of debris and smear layer has been found in canals shaped with ProFile instruments, and the largest amount in canals shaped with FlexMaster instruments. Canal cleaning efficacy of hand GT and ProTaper files has been similar to cleaning efficacy of rotary NiTi files. Statistic analysis has shown a significant difference in amount of dentine debris and smear layer on the canal walls between sample groups shaped with different instruments. Conclusion. Completely clean canals have not been found in any tested group of instruments. The largest amount of debris and smear layer has been found in the apical third of all canals. The design and the type of endodontic instruments influence the efficacy of the canal cleaning.

  8. Infected Hydrocele of the Canal of Nuck

    Directory of Open Access Journals (Sweden)

    Parkash Mandhan

    2013-01-01

    Full Text Available Hydrocele of the canal of Nuck in children is rare. It may present as incarcerated inguinal hernia and necessitates emergency exploration. Risk of infection in hydrocele of the canal of nuck is very rare. We present a case report of a 5-year-old girl who presented with a left tender inguinolabial region swelling with fever, tachycardia, and mild dehydration. The clinical features were suggestive of strangulated left inguinal hernia and further imaging and surgical exploration revealed it to be an infected hydrocele of the canal of Nuck. High ligation and hydrocelectomy were performed. Hydrocele of the canal of Nuck in a female child presenting with an inguinal swelling should be considered in differential diagnosis.

  9. Action antiadipogenic of weak magnetic fields: A model for the study of the etiology of the semicircular lipoatrophy in media occupational; Accion antiadipogenica de campos magneticos debiles: un modelo para el estudio de la etiologia de la lipoatrofia semicircular en medios ocupacionales

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Pascual, M. A.; Paino Belarrinaga, C. L.; Trillo ruiz, M. A.; Ubeda Maeso, A.

    2013-07-01

    Although several studies have suggested a possible association between exposure to environmental magnetic fields of industrial frequency and semicircular lipoatrophy, a mechanism that justifies the potential action of these fields magnetic on the adipo genesis has not been identified. The study investigated the in vitro action of a field weak magnetic on the adipo genesis of human adipose tissue-derived stem cells. (Author)

  10. Mechanics of the Panama Canal slides

    Science.gov (United States)

    Becker, George F.

    1917-01-01

    Dr. Becker visited the Canal Zone in 1913 as a geologist of the United States Geological Survey and since that time has given the problem the benefit of his study. His appointment as a member of the committee of the National Academy of Sciences has made it appropriate for his conclusions, based upon his personal observations and already reported in part to the Canal Commission, to be stated for the benefit of his associates and other American scientists and engineers.

  11. Experimental investigation on a semi-circular trough-absorber solar still with baffles for fresh water production

    International Nuclear Information System (INIS)

    Sathyamurthy, Ravishankar; Nagarajan, P.K.; El-Agouz, S.A.; Jaiganesh, V.; Sathish Khanna, P.

    2015-01-01

    Highlights: • Experiments are carried out to analyze the performance. • Baffles are placed in the absorber to increase the residence time of water with solar intensity. • Yield of fresh water from present solar still is 16.66% more than a conventional solar still. • Payback period of the present model is quicker. - Abstract: The main objective of this research is to increase the contact time of water in the basin to enhance yield of fresh water by using a semicircular absorber solar still with baffles. An experimental as well as theoretical investigation is carried out. The productivity and efficiency of present still are analyzed with the influence of the number baffles and the water flow rate. A good agreement between the experimental and theoretical results is observed. The results indicate that, the daily yield of present solar still is higher than that for conventional still approximately by 16.66%. The outlet water temperature present solar still is high subsequently, it can be coupled with multi-state of solar stills to increase productivity. Therefore, the present solar still can be sufficiently extended for other continuous solar desalination systems. Economic analysis concluded that, the payback period of the present model solar still is quicker while comparing it with other solar still

  12. A Low-Profile Dual-Layer Patch Antenna with a Circular Polarizer Consisting of Dual Semicircular Resonators

    Directory of Open Access Journals (Sweden)

    Li Guo

    2018-06-01

    Full Text Available In this paper, a circular polarizer comprising dual semicircular split-rings (DSSRs is presented. By placing it above an elliptical radiator that radiates linearly polarized (LP waves, dual-layer patch antennas capable of radiating right-hand (RH or left-hand (LH circularly polarized (CP waves are achieved in terms of the different offset direction of the bottom splits of the DSSRs. Because of both the capacitive coupling to the radiator and the degenerate modes existing in the excited DSSRs, the DSSRs collaboratively result in a circularly polarized radiation, successfully converting incident LP waves into CP ones. Simulated results show that the impedance, axial ratio (AR, and gain frequency response of both proposed CP antennas are identical, with a simulated 3-dB AR bandwidth of 72 MHz covering 2.402–2.474 GHz and a gain enhanced by 3.9 dB. The proposed antennas were fabricated and measured, revealing an operational bandwidth of 65 MHz (2.345–2.41 GHz and a peak gain up to 9 dBi. Moreover, a low profile of 0.063λ0 is maintained. The proposed CP antennas could be as a candidate for wireless target detection applications in terms of their identical frequency response property.

  13. External auditory canal carcinoma treatment

    International Nuclear Information System (INIS)

    Matsuda, Yoichi; Ueda, Yoshihisa; Kurita, Tomoyuki; Nakashima, Tadashi

    2010-01-01

    External auditory canal (EAC) carcinomas are relatively rare conditions lack on established treatment strategy. We analyzed a treatment modalities and outcome in 32 cases of EAC squamous cell carcinoma treated between 1980 and 2008. Subjects-17 men and 15 women ranging from 33 to 92 years old (average: 66) were divided by Arriaga's tumor staging into 12 T1, 5 T2, 6 T3, and 9 T4. Survival was calculated by the Kaplan-Meier method. Disease-specific 5-year survival was 100% for T1, T2, 44% for T3, and 33% for T4. In contrast to 100% 5-year survival for T1+T2 cancer, the 5-year survival for T3+T4 cancer was 37% with high recurrence due to positive surgical margins. The first 22 years of the 29 years surveyed, we performed surgery mainly, and irradiation or chemotherapy was selected for early disease or cases with positive surgical margins as postoperative therapy. During the 22-years, 5-year survival with T3+T4 cancer was 20%. After we started superselective intra-arterial (IA) rapid infusion chemotherapy combined with radiotherapy in 2003, we achieved negative surgical margins for advanced disease, and 5-year survival for T3+T4 cancer rise to 80%. (author)

  14. Oralidad en el Canal Pimp Placo

    Directory of Open Access Journals (Sweden)

    Miguel Espigado

    2017-11-01

    Full Text Available Pimp Flaco, a trap artist from Barcelona, and his thousands of fans that follow his public profiles in Instagram and Twitter and Youtube, have created a multi-channel of complex orality where art reception and art work become one. Artist and followers’ messages mix art and comunication, up to the point of culture stopping to be a code separated of ordinary communication, and it’s used as a whole by the community for reelaborate and obtain its collective codes. Pimp Flaco, as Homero did, is not well defined by absolute originality, but his talent consist in invoking a serie of subjects, topics and collective formulas. The cooperative use of verbal violence stands out among them.

  15. The fluid mechanics of root canal irrigation.

    Science.gov (United States)

    Gulabivala, K; Ng, Y-L; Gilbertson, M; Eames, I

    2010-12-01

    Root canal treatment is a common dental operation aimed at removing the contents of the geometrically complex canal chambers within teeth; its purpose is to remove diseased or infected tissue. The complex chamber is first enlarged and shaped by instruments to a size sufficient to deliver antibacterial fluids. These irrigants help to dissolve dying tissue, disinfect the canal walls and space and flush out debris. The effectiveness of the procedure is limited by access to the canal terminus. Endodontic research is focused on finding the instruments and clinical procedures that might improve success rates by more effectively reaching the apical anatomy. The individual factors affecting treatment outcome have not been unequivocally deciphered, partly because of the difficulty in isolating them and in making the link between simplified, general experimental models and the complex biological objects that are teeth. Explicitly considering the physical processes within the root canal can contribute to the resolution of these problems. The central problem is one of fluid motion in a confined geometry, which makes the dispersion and mixing of irrigant more difficult because of the absence of turbulence over much of the canal volume. The effects of treatments can be understood through the use of scale models, mathematical modelling and numerical computations. A particular concern in treatment is that caustic irrigant may penetrate beyond the root canal, causing chemical damage to the jawbone. In fact, a stagnation plane exists beyond the needle tip, which the irrigant cannot penetrate. The goal is therefore to shift the stagnation plane apically to be coincident with the canal terminus without extending beyond it. Needle design may solve some of the problems but the best design for irrigant penetration conflicts with that for optimal removal of the bacterial biofilm from the canal wall. Both irrigant penetration and biofilm removal may be improved through canal fluid

  16. The fluid mechanics of root canal irrigation

    International Nuclear Information System (INIS)

    Gulabivala, K; Ng, Y-L; Gilbertson, M; Eames, I

    2010-01-01

    Root canal treatment is a common dental operation aimed at removing the contents of the geometrically complex canal chambers within teeth; its purpose is to remove diseased or infected tissue. The complex chamber is first enlarged and shaped by instruments to a size sufficient to deliver antibacterial fluids. These irrigants help to dissolve dying tissue, disinfect the canal walls and space and flush out debris. The effectiveness of the procedure is limited by access to the canal terminus. Endodontic research is focused on finding the instruments and clinical procedures that might improve success rates by more effectively reaching the apical anatomy. The individual factors affecting treatment outcome have not been unequivocally deciphered, partly because of the difficulty in isolating them and in making the link between simplified, general experimental models and the complex biological objects that are teeth. Explicitly considering the physical processes within the root canal can contribute to the resolution of these problems. The central problem is one of fluid motion in a confined geometry, which makes the dispersion and mixing of irrigant more difficult because of the absence of turbulence over much of the canal volume. The effects of treatments can be understood through the use of scale models, mathematical modelling and numerical computations. A particular concern in treatment is that caustic irrigant may penetrate beyond the root canal, causing chemical damage to the jawbone. In fact, a stagnation plane exists beyond the needle tip, which the irrigant cannot penetrate. The goal is therefore to shift the stagnation plane apically to be coincident with the canal terminus without extending beyond it. Needle design may solve some of the problems but the best design for irrigant penetration conflicts with that for optimal removal of the bacterial biofilm from the canal wall. Both irrigant penetration and biofilm removal may be improved through canal fluid

  17. Industrial canal waterfronts in The Netherlands : transforming the canal zones of B5

    NARCIS (Netherlands)

    Curulli, G.I.

    2012-01-01

    Industrial Canal Waterfronts in The Netherlands provides a comprehensive presentation of the characteristics and challenges of five interconnected and dismissed industrial canal zones located in the Dutch Brabant cities of Eindhoven, Breda, Tilburg, s’-Hertogenbosch and Helmond (B5). Through the

  18. 77 FR 42644 - Safety Zone; Canal Fest of the Tonawandas, Erie Canal, Tonawanda, NY

    Science.gov (United States)

    2012-07-20

    .... ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary safety zone on the... Canal during the Canal Fest of the Tonawandas Fireworks display. This temporary safety zone is necessary to protect spectators and vessels from the hazards associated with a fireworks display. DATES: This...

  19. Radiation-induced external ear canal cholesteatoma-like disease

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Akiko; Okuno, Hideji; Noguchi, Keisuke; Komatsuzaki, Atsushi [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1999-06-01

    Three cases of cholesteatoma-like disease in the ear canals after radiation therapy for head and neck tumor were reported. Effect of irradiation on bone and soft tissue including skin brings about pathological reaction to the external ear canal as well. Two types of disease resembling cholesteatomas have been recognized: keratosis obturans (KO) and external auditory canal cholesteatoma (EACC). KO appears to be derived from disease of canal skin involved with keratinization, creating a widning of the canal. EACC, on the other hand, seems to develop in the disease of bony canal where a localized absorption of its bone with invasion of squamous epithelium takes place. (author)

  20. Comportamiento de mezclas asfálticas densas a partir del ensayo de viga semicircular simplemente apoyada

    Directory of Open Access Journals (Sweden)

    Luis Alberto Paredes Chérrez

    2014-04-01

    Full Text Available La caracterización mecánica y dinámica de mezclas asfálticas es costosa y demorada por la complejidad y el número de ensayos necesarios para su ejecución. Sin embargo, algunas investigaciones han tratado de establecer correlaciones con ensayos más sencillos, rápidos y económicos. Por esta razón, el objetivo principal de esta investigación fue establecer la viabilidad del uso del ensayo de Viga Semicircular Simplemente Apoyada (SCB en la caracterización de mezclas asfálticas cerradas con granulometrías del Instituto de Desarrollo Urbano (IDU y del Instituto Nacional de Vías (Invias, con diferentes propiedades. El estudio inició con la fabricación de probetas SCB con diferentes materiales (agregados, asfaltos, asfaltita, asfalto reciclado y cal y procesos de compactación (vibrocompación y con prensa giratoria. Los ensayos se realizaron a una velocidad de 1 mm/min, una temperatura de 15 °Cy con la medición de los parámetros carga máxima, desplazamiento a carga máxima, energía liberada durante el proceso de fisuración, índice de rigidez a tracción e índice de tenacidad y variables definidas en el ensayo Fénix. De los resultados obtenidos, se pudo establecer que irrelevantemente del material empleado, el periodo de envejecimiento, el nivel de compactación y el reemplazo de filler, el ensayo SCB y los parámetros calculados evidencian el comportamiento de las mezclas asfálticas estudiadas y plantear su uso como herramienta.

  1. Magnetic spectrograph with a semicircular focusing for studies on the energy distribution of a high-current relativistic electron beam

    International Nuclear Information System (INIS)

    Gosteva, T.S.; Zablotskaya, G.R.; Ivanov, B.A.; Kolyubakin, S.A.; Chernobrovin, V.I.

    1975-01-01

    Specific features of a magnetic spectrograph with a semicircular focusing are described; the spectrograph has been designed to study, using the REP-5 pulsed accelerator, the energy spectra of electrons with a current of 50 kA, pulse duration of 20 ns in the energy range 0.2 to 3 MeV. The beam has been transported in a drift chamber where the air pressure varies from 10 -3 to 40 torr. The chamber is 50 cm long and 12 cm in diameter. The spectrograph vacuum chamber is made in the form of a plane rectangular box with a degassing fitting. The uniform magnetic field in the spectrograph gap is provided with permanent magnets (ferrite-barium plates). The collimator and the chamber walls on which the magnets are located, are made of low-carbon electrotechnical steel. The diameters of the collimator entrance and exit windows are 2 and 0.2 mm, respectively. To screen the photofilm in the spectrograph chamber from x-radiation, there are three disks on the spectrograph flange on the part of the drift chamber, they are made of lead, steel, and aluminium. The steel disk, besides, screens the space in front of the collimator entrance window from the scattered magnetic field. During the experiments the pressure in the spectrograph chamber has varied from 7x10 -3 to 10 -1 torr. Electrons are registered using the RT-1 and RT-5 x-ray films 1x18 cm in size. The spectrograph described makes it possible to have well-resolved electron spectrum during a pulse. The electron spectra obtained by means of the spectrograph at a pressure of 4.10 -1 torr in the drift chamber and a charge voltage of 3.2 MV in the line, are shown [ru

  2. Root canal treatment and special needs patients.

    Science.gov (United States)

    Yap, E; Parashos, P; Borromeo, G L

    2015-04-01

    To identify current trends of root canal treatment for patients with special needs. A postal questionnaire was sent to General Dentists in Victoria, Australia and Endodontists and Special Needs Dentists across Australia to determine the extent of root canal treatment performed on special needs patients. Over a four-month period, 1120 questionnaires were distributed with an overall response rate of 63.9% (n = 716). Response rates were 63.2% (n = 655), 68.5% (n = 50) and 100.0% (n = 11) amongst General Dentists, Endodontists and Special Needs Dentists, respectively. Endodontists (95.7%) and Special Needs Dentists (100.0%) performed significantly more root canal treatment on adult patients with special needs compared with 51.2% of General Dentists, (P special needs patients compared with only 29.7% of General Dentists (P special needs patients was more likely to be carried out by specialist dental practitioners who were more likely to utilize a pharmacological approach for behaviour guidance and to perform single-visit root canal treatment compared with General Dentists. A multidisciplinary approach for special needs patients who require root canal treatment provides an opportunity for these patients to retain their dentition. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  3. Computed tomography in lumbar canal stenosis

    International Nuclear Information System (INIS)

    Ohta, Shu; Baba, Itsushi; Ishida, Akihisa; Sumida, Tadayuki; Sasaki, Seishu

    1984-01-01

    Preoperative CT was done in 39 patients with lumbar canal stenosis. Marked symmetrical narrowing of the whole vertebral canal was seen in the group with nervous symptoms in the cauda equina. Deformed bilateral intervertebral joints were seen in the group with both nervous symptoms in the cauda equina and radicular sciatica. The lateral recess on the affected side was markedly narrowed by the projection of the upper and lower joints and herniation. In the group with radicular sciatica, the vertebral canal itself was not so narrowed, but the unilateral intervertebral joint was extremely deformed, causing a narrowing of the lateral recess. There were large differences in the angle of the left and right intervertebral joints. (Namekawa, K)

  4. Canal shaping of different single-file systems in curved root canals

    Directory of Open Access Journals (Sweden)

    Maurizio D'Amario

    2017-12-01

    Full Text Available Background/Purpose: This study compared maintenance of canal anatomy, occurrence of apical transportation, and working time observed after instrumentation with One Shape New Generation rotary system (Micro-Mega, with those observed after instrumentation with Reciproc (VDW and WaveOne (Dentsply-Maillefer reciprocating systems. Materials and methods: The mesial canals of 45 mandibular molars (curvature angles between 35° and 45° were selected. Specimens were randomly divided into three groups, and canal preparations were performed using One Shape, Reciproc, or WaveOne systems (size #25. A digital double radiographic technique was used to determine apical transportation and change in angle of curvature. Also, working time and instrument failures were recorded. Data were statistically analyzed. Results: During preparation, no file fractured. No statistically significant differences were found among groups. No system showed a significantly faster preparation time than others (P>0.05. All instruments maintained the original canal curvature well and were safe to use. Conclusion: Both continuous rotary instrument and reciprocating systems did not have any influence on the presence of apical transportation or caused an alteration in angle of canal curvature. Keywords: canal curvature, canal straightening, endodontics, reciprocating motion, single file instrumentation

  5. Decreased levels of matrix metalloproteinase-2 in root-canal exudates during root canal treatment.

    Science.gov (United States)

    Pattamapun, Kassara; Handagoon, Sira; Sastraruji, Thanapat; Gutmann, James L; Pavasant, Prasit; Krisanaprakornkit, Suttichai

    2017-10-01

    To determine the matrix metalloproteinase-2 (MMP-2) levels in root-canal exudates from teeth undergoing root-canal treatment. The root-canal exudates from six teeth with normal pulp and periradicular tissues that required intentional root canal treatment for prosthodontic reasons and from twelve teeth with pulp necrosis and asymptomatic apical periodontitis (AAP) were sampled with paper points for bacterial culture and aspirated for the detection of proMMP-2 and active MMP-2 by gelatin zymography and the quantification of MMP-2 levels by ELISA. By gelatin zymography, both proMMP-2 and active MMP-2 were detected in the first collection of root-canal exudates from teeth with pulp necrosis and AAP, but not from teeth with normal pulp, and their levels gradually decreased and disappeared at the last collection. Consistently, ELISA demonstrated a significant decrease in MMP-2 levels in the root-canal exudates of teeth with pulp necrosis and AAP following root canal procedures (papical lesions, similar to the clinical application of MMP-8 as a biomarker. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Incidence and characteristics of mandibular accessory canals: A radiographic investigation.

    Science.gov (United States)

    Borgonovo, Andrea Enrico; Taschieri, Silvio; Vavassori, Virna; Re, Dino; Francetti, Luca; Corbella, Stefano

    2017-11-01

    The aim of the present study was to explore, through tridimensional reconstructions of cone-beam computed tomography (CBCT) scans, the presence and the characteristics of mandibular accessory canals. For each included participant, the presence of accessory canals was recorded. The diameter of the canal, as well as the distance between the canal walls and the walls of the mandibular bone (lingual, buccal, cranial and caudal), were measured and recorded. Mandibular accessory canals could be found in 8.8% of participants. Retromolar canals were the most frequently found accessory mandibular canals. Accessory mandibular canals were found in a relatively high number of participants through the examination of CBCT scans and tridimensional reconstruction. The presence of such structures should be considered cautiously when planning and performing surgical interventions in mandibular area. © 2017 John Wiley & Sons Australia, Ltd.

  7. Radiographic versus electronic root canal working length determination

    Directory of Open Access Journals (Sweden)

    Lumnije Kqiku

    2011-01-01

    Conclusions: The present ex vivo study showed that electronic root canal working length determination is not superior to radiographic methods. Both methods provided a good performance in determining the root canal working length.

  8. Report from the Panama Canal Stakeholder Working Group.

    Science.gov (United States)

    2013-03-01

    This project assists the Texas Department of Transportation (TxDOT) in assessing the potential impacts of the Panama Canal expansion on Texas ports and the landside transportation system. TxDOT formed a Panama Canal Stakeholder Working Group (PCSWG) ...

  9. Controlling the Flow past a Semicircular Airfoil at Zero Angle of Attack Using Slot Suction in One or Two Vortex Cells for Attaining Extremal Lift

    Science.gov (United States)

    Isaev, S. A.; Baranov, P. A.; Sudakov, A. G.; Popov, I. A.; Usachov, A. E.

    2017-12-01

    Calculations using multiblock computational technologies and a model of shear-stress transport modified with allowance for the curvature of streamlines in turbulent airflow were performed at a zero angle of attack for a semicircular airfoil containing one or two surface vortex cells with slot suction. The results showed evidence of stabilization of a nearly undetached flow and attainment of an extremal lift of C y = 5.2 and a lift-to-drag ratio of K = 24 with allowance for energy losses for suction in the vortex cells.

  10. Direct Acoustic Stimulation at the Lateral Canal: An Alternative Route to the Inner Ear?

    Directory of Open Access Journals (Sweden)

    Nicolas Verhaert

    Full Text Available Severe to profound mixed hearing loss is associated with hearing rehabilitation difficulties. Recently, promising results for speech understanding were obtained with a direct acoustic cochlear implant (DACI. The surgical implantation of a DACI with standard coupling through a stapedotomy can however be regarded as challenging. Therefore, in this experimental study, the feasibility of direct acoustic stimulation was investigated at an anatomically and surgically more accessible inner ear site. DACI stimulation of the intact, blue-lined and opened lateral semicircular canal (LC was investigated and compared with standard oval window (OW coupling. Additionally, stapes footplate fixation was induced. Round window (RW velocity, as a measure of the performance of the device and its coupling efficiency, was determined in fresh-frozen human cadaver heads. Using single point laser Doppler vibrometry, RW velocity could reliably be measured in low and middle frequency range, and equivalent sound pressure level (LE output was calculated. Results for the different conditions obtained in five heads were analyzed in subsequent frequency ranges. Comparing the difference in RW membrane velocity showed higher LE in the LC opened condition [mean: 103 equivalent dB SPL], than in LC intact or blue-lined conditions [63 and 74 equivalent dB SPL, respectively]. No difference was observed between the LC opened and the standard OW condition. Inducing stapes fixation, however, led to a difference in the low frequency range of LE compared to LC opened. In conclusion, this feasibility study showed promising results for direct acoustic stimulation at this specific anatomically and surgically more accessible inner ear site. Future studies are needed to address the impact of LC stimulation on cochlear micromechanics and on the vestibular system like dizziness and risks of hearing loss.

  11. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    Background: Normal values of lumbar vertebral canal diameters are useful in facilitating diagnosis of lumbar vertebral canal stenosis. Various studies have established variation on values between different populations, gender, age, and ethnic groups. Objectives: To determine the lumbar vertebral canal diameters in adult ...

  12. Newer Root Canal Irrigants in Horizon: A Review

    Directory of Open Access Journals (Sweden)

    Sushma Jaju

    2011-01-01

    Full Text Available Sodium hypochloride is the most commonly used endodontic irrigant, despite limitations. None of the presently available root canal irrigants satisfy the requirements of ideal root canal irrigant. Newer root canal irrigants are studied for potential replacement of sodium hypochloride. This article reviews the potential irrigants with their advantages and limitations with their future in endodontic irrigation.

  13. Comparison of Curved Root Canals Prepared with Various Chelating Agents

    Science.gov (United States)

    2012-06-01

    aqueous base (11). According to Bramante and Betti, instrumentation with NiTi hand files using EDTA caused greater deviation of the root canal from...15. Peters OA, Peters CI, Schonenberger K, Barbakow F. ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by

  14. Middle mesial canals in mandibular molars: incidence and related factors.

    Science.gov (United States)

    Nosrat, Ali; Deschenes, Raney J; Tordik, Patricia A; Hicks, M Lamar; Fouad, Ashraf F

    2015-01-01

    Although the internal anatomy of mandibular molars has been extensively studied, information about middle mesial (MM) canals is limited. The primary aim of this retrospective study was to evaluate the incidence of MM canals in mandibular first and second molars. The secondary aim was to correlate the incidence of MM canals with variables of molar type, sex, age, ethnicity, and presence of a second distal canal. All mature permanent first and second mandibular molars treated from August 2012 to May 2014 were included in the analysis. After completion of root canal instrumentation in all main canals, the clinician inspected the isthmus area of the mesial root using the dental operating microscope. If there was a catch point in this area with a file or explorer, the operator spent more time attempting to negotiate an MM canal. Seventy-five mandibular first and second molars were treated during the specified period. Fifteen (20%) teeth had negotiable MM canals. The incidence of MM canals was 32.1% in patients ≤ 20 years old, 23.8% in patients 21-40 years old, and 3.8% in patients > 40 years. Analysis of data revealed a significant difference in the distribution of MM canals among different age groups (P molar type, and presence of a second distal canal were not significant. The incidence of negotiable MM canals overall and their frequency of identification in younger patients were higher than in previous reports. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. 21 CFR 872.3820 - Root canal filling resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...

  16. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    International Nuclear Information System (INIS)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul

    2001-01-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  17. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  18. Periapical repair after root canal filling with different root canal sealers.

    Science.gov (United States)

    Tanomaru-Filho, Mário; Tanomaru, Juliane Maria Guerreiro; Leonardo, Mario Roberto; da Silva, Lea Assed Bezerra

    2009-01-01

    The aim of this study was to evaluate periapical repair after root canal filling with different endodontic sealers. Sixty-four root canals from dog s teeth were filled, divided into 4 groups (n=16). Root canals were instrumented with K-type files and irrigated with 1% sodium hypochlorite solution. Root canals were filled in the same session by active lateral condensation of the cones and sealers: Intrafill, AH Plus, Roeko Seal and Resilon/Epiphany System. After 90 days, the animals were euthanized and the tissues to be evaluated were processed and stained with hematoxylin and eosin. For histopathological analysis, the following parameters were evaluated: inflammatory process, mineralized tissue resorption, and apical mineralized tissue deposition. Histopathological analysis demonstrated that Intrafill had less favorable results in terms of apical and periapical repair, compared to the other sealers (p0.05). In conclusion, AH Plus and the materials Roeko Seal and Epiphany are good options for clinical use in Endodontics.

  19. The Suez Canal and the petroleum harbors

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    The Suez Canal is the second longest channel in the world and allows to save 60% of the travel time between the petroleum harbors of the Arabic peninsula and Europe. This short paper gives a summary of the main petroleum harbors activity along the channel from the Red sea to the Mediterranean sea. (J.S.)

  20. Note on Tendipedidae of the Suez Canal

    NARCIS (Netherlands)

    Kruseman, G.

    1949-01-01

    Mr. A. C. V. VAN BEMMEL and Dr. A. DIAKONOFF of the Buitenzorg Museum (Java) collected Tendipedidae, which were attracted by artificial lights, when they passed the Suez Canal on 8-XI-1937 and 16-V-1939 respectively. This very interesting collection, containing some new species, was sent to me for