WorldWideScience

Sample records for mrt und 4-zeilen-spiral-ct

  1. Imaging diagnostics of the wrist: MRI and Arthrography/Arthro-CT; Bildgebende Diagnostik des Handgelenkes: MRT und Arthrographie/Arthro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Klein, H.M.; Balas, R.; Neugebauer, F. [Radiologische Gemeinschaftspraxis, Betzdorf (Germany); Vrsalovic, V. [Handchirugie, Marienhospital Siegen, Siegen (Germany)

    2002-02-01

    Purpose: To evaluate the use of magnetic resonance imaging (MRI) compared with arthrography and arthro-CT (AG/ACT) in patients with wrist pain. Methods: MRI and arthrography/arthro-CT (AG/ACT) of the wrist joint were retrospectively evaluated in 346 patients over a three-year period. Imaging findings were correlated to surgical results (n=78) or clinical course in an at least 6-month follow-up. Results: For tears of the triangular fibrocartilage, arthrography, arthro-CT, and MRI demonstrated a sensitivity and specificity of more than 0.96. Only the positive predictive value was superior for arthrography/arthro-CT (0.99 and 0.98, respectively) compared with MRI (0.94). Arthrography was superior for functional diagnosis of scapho-lunate ligament tears (n=25). Ulno-lunate and ulno-triquetral ligament defects were demonstrated more exactly by arthrography. Traumatic osseous defects, particularly scaphoid fractures (n=33) and avascular necrosis (n=17), were better diagnosed using MRI. Conclusion: For suspected lesions of the triangular fibrocartilage complex, AG/ACT is slightly more reliable than MRI. However, MRI was found to be highly accurate in diagnosing TFC tears, and is superior to AG/ACT in detecting traumatic and vascular lesions of the wrist. (orig.) [German] Ziel: Die Untersuchung der diagnostischen Aussagekraft von Magnetresonanz-Tomographie (MRT), Arthrographie (AG) und Arthro-CT (ACT) bei Erkrankungen des Handgelenkes. Methodik: Insgesamt 346 Untersuchungen des Handgelenkes wurden fuer einen dreijaehrigen Beobachtungszeitraum retrospektiv ausgewertet. Es wurden 211 MRT, 151 Arthrographien (AG) und 126 Arthro-CT (ACT) durchgefuehrt. Alle Diagnosen wurden operativ (n=78) oder durch den klinischen Verlauf in einer 6-monatigen Nachbeobachtung gesichert. Ergebnisse: Fuer die Diagnostik von Laesionen des diskoulnaren Komplexes lag die Sensitivitaet und Spezifitaet von AG, ACT und MRT ueber 0,96. Lediglich der positive Vorhersagewert differierte, allerdings nicht

  2. CT and MRI of the liver: when, what, why?; CT und MRT der Leber: wann, was, warum

    Energy Technology Data Exchange (ETDEWEB)

    Budjan, J.; Schoenberg, S.O.; Attenberger, U.I. [Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Mannheim (Germany)

    2017-05-15

    The detection and differential diagnostic clarification of liver pathologies play an important role in almost all medical disciplines. Because of its superior soft tissue contrast, the availability of liver-specific contrast agents and functional techniques, magnetic resonance imaging (MRI) is the method of choice for the diagnostics of focal and diffuse liver pathologies. In addition to its superior detection and differentiation capabilities, MRI can provide prognostic information and enable early assessment of the therapy response for malignant liver lesions using functional techniques, especially diffusion imaging. Computed tomography (CT) is the imaging method of choice for the detection of traumatic liver injury. Despite the increasing availability of functional techniques in CT, MRI remains the overall modality of choice in liver imaging. (orig.) [German] Die Detektion und die differenzialdiagnostische Abklaerung von Leberpathologien spielen in nahezu allen medizinischen Disziplinen eine bedeutende Rolle. Ihre Vorteile in Hinblick auf Weichteilkontrast, die Verfuegbarkeit leberspezifischer Kontrastmittel und funktionelle Techniken machen die MRT zum bildgebenden Verfahren der Wahl fuer die gezielte Abklaerung fokaler oder diffuser Leberpathologien. Neben hoeheren Detektionsraten und besseren Differenzierungsmoeglichkeiten stehen in der MRT funktionelle Techniken - insbesondere die Diffusionsbildgebung - zur Verfuegung, die eine Prognoseabschaetzung und die fruehe Beurteilung von Therapieansprechen bei malignen Leberlaesionen erlauben. Die CT ist bei der Detektion traumatischer Leberverletzungen Bildgebungsverfahren der Wahl; trotz der auch in der CT zunehmend verfuegbaren funktionellen Techniken bleibt die MRT in der Leberbildgebung weiterhin ueberlegen. (orig.)

  3. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT; Fruehes klinisches Management nach Polytrauma mit 1- und 4-Schicht-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kloeppel, R.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schreiter, D. [Chirurgische Intensivtherapieabteilung, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany); Dietrich, J. [Abt. Neuroradiologie der Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Josten, C. [Klinik und Poliklinik fuer Unfall- und Wiederherstellungschirurgie, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany)

    2002-07-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of {approx}30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by {approx}4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [German] Die klinische Erstversorgung Polytraumatisierter schliesst inzwischen in vielen Unfallkliniken den fruehzeitigen Einsatz der Spiral-CT ein. Kann die neuerlich eingefuehrte Mehrschicht-Spiral-CT Ergebnisse und Patientenmanagement weiter verbessern?Nach lebensrettenden Sofortmassnahmen, Thoraxroentgen und Notsonographie im Schockraum erfolgte die CT: Von 1998-2000 wurden 241 Patienten mit einem 1-Schicht-Spiral-CT (Somatom plus 4) und in 2001 79 Patienten mit einem 4-Schicht-Spiral-CT (Somatom VZ, beide Siemens Med. Sol.) untersucht. Klinisch ausgewaehlte Extremitaetenaufnahmen wurden ergaenzt.359 von 360 Untersuchungen verliefen erfolgreich

  4. Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences; Darstellung der Herzkranzgefaesse im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Heuschmid, M.; Kuettner, A.; Kopp, A.F.; Claussen, C.D. [Abt. Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Flohr, T.; Schaller, S.; Hartung, A.; Ohnesorge, B. [Siemens Medical Solutions, Forchheim (Germany); Wildberger, J.E. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum (RWTH) Aachen (Germany); Lell, M.; Baum, U. [Abt. Innere Medizin IV (Kardiologie), Universitaetsklinikum Tuebingen (Germany); Schroeder, S. [Inst. fuer Diagnostische Radiologie, Universitaetsklinikum Erlangen (Germany)

    2002-06-01

    Purpose: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. Materials and Methods: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a {beta}-Blocker, the heart rate was between 55 and 67 bpm. Results: The scan time for calcium score was 12s, for CTA 18s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. Conclusion: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated. (orig.) [German] Ziel: Darstellung erster Ergebnisse zur Bildqualitaet eines neuen 16-Zeilen Multidetektor-Computertomographen (MDCT) bei der Diagnostik der koronaren Herzerkrankung (KHK) und hochgradiger Stenosen der Herzkranzgefaesse. Material und Methode: Mit einem neuen 16-Zeilen-Computertomographen (SOMATOM Sensation 16, Siemens, Forchheim) wurde bei 4 Patienten zum Ausschluss oder

  5. CT and MRI normal findings; CT- und MRT-Normalbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, T.B.; Reif, E. [Caritas-Krankenhaus, Dillingen (Germany)

    1998-07-01

    This book gives answers to questions frequently heard especially from trainees and doctors not specialising in the field of radiology: Is that a normal finding? How do I decide? What are the objective criteria? The information presented is three-fold. The normal findings of the usual CT and MRI examinations are shwon with high-quality pictures serving as a reference, with inscribed important additional information on measures, angles and other criteria describing the normal conditions. These criteria are further explained and evaluated in accompanying texts which also teach the systematic approach for individual picture analysis, and include a check list of major aspects, as a didactic guide for learning. The book is primarily intended for students, radiographers, radiology trainees and doctors from other medical fields, but radiology specialists will also find useful details of help in special cases. (orig./CB) [German] Normalbefunde sind die haeufigsten Befunde ueberhaupt. Also kein Problem? Doch. Besonders Radiologen in der Ausbildung und Aerzte aus anderen Fachgebieten stellen sich immer wieder die entscheidende Frage: Ist das normal? Woran kann ich das erkennen? Wie kann ich das objektivieren? Dieses Buch leistet dreierlei: 1. Es zeigt klassische Normalbefunde der gaengigen CT- und MRT-Untersuchungen in hoher Abbildungsqualitaet als Referenz. Direkt in die Aufnahmen eingezeichnet sind wichtige Daten: Masse, Winkel und andere Kriterien des Normalen. Sie werden im Text nochmals zusammengefasst, erklaert und bewertet. 2. Es lehrt die Systematik der Bildbetrachtung - wie schaue ich mir ein Bild an, welche Strukturen betrachte ich in welcher Reihenfolge und worauf muss ich dabei besonders achten? Dies alles in Form einer uebersichtlichen Checkliste zu jeder Aufnahme. 3. Es gibt eine Befundformulierung vor, die sich wiederum an dem Schema der Bildanalyse orientiert, alle Kriterien des Normalen definiert und dadurch auch ein wichtiges didaktisches Element darstellt

  6. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI; Multiparametrische und molekulare Bildgebung von Brusttumoren mit MRT und PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Memorial Sloan-Kettering Cancer Center, Department of Radiology, Molecular Imaging and Therapy Service, New York (United States); State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Marino, M.A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Policlinico Universitario G. Martino, University of Messina, Department of Biomedical Sciences and Morphologic and Functional Imaging, Messina (Italy); Meyer-Baese, A. [State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Helbich, T.H. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria)

    2016-07-15

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ({sup 1}H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ({sup 23}Na MRI), phosphorus spectroscopy ({sup 31}P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [German] Die Magnetresonanztomographie (MRT) der Brust ist ein etabliertes nichtinvasives bildgebendes Verfahren mit vielfaeltigen Indikationen. In den letzten Jahren wurden zahlreiche funktionelle MRT- und Positronenemissionstomographie(PET)-Parameter in der Brustbildgebung evaluiert, und ihre kombinierte Anwendung ist als multiparametrische Bildgebung definiert. Bisherige Daten legen nahe, dass die multiparametrische Bildgebung mit MRT und PET

  7. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  8. Accuracy of renal volume assessment in children by three-dimensional sonography; Nierenvolumetrie im Kindesalter: Genauigkeit der dreidimensionalen Sonographie im Vergleich zur konventionellen Sonographie und CT/MRT

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, G.A.; Riccabona, M.; Bohdal, G. [Klinik fuer Radiologie, Universitaetsklinikum Graz (Austria); Quehenberger, F. [Inst. fuer medizinische Informatik, Statistik und Dokumentation, Universitaetsklinikum Graz (Austria)

    2003-04-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 {+-} 4.6% versus a mean difference of -2.4 {+-} 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 {+-} 4.4% for 3DUS and -3.8 {+-} 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 {+-} 5.9% and +9.6 {+-} 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were {+-} 7.3% and {+-} 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [German] Studienziel: Prospektive Evaluation der Genauigkeit des drei-dimensionalen Ultraschalls (3DUS) bei der Volumetrie der kindlichen Niere im Vergleich zur CT/MRT. Methode: Bei 40 Patienten (Alter: 0 - 17 Jahre) mit einer klinisch indizierten CT/MRT des Abdomens oder des Harntrakts wurde zusaetzlich ein 2D- und 3DUS inklusive Volumetrie des

  9. Image fusion of MRI and fMRI with intraoperative MRI data: methods and clinical relevance for neurosurgical interventions; Fusion von MRT-, fMRT- und intraoperativen MRT-Daten. Methode und klinische Bedeutung am Beispiel neurochirurgischer Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Moche, M.; Busse, H.; Dannenberg, C.; Schulz, T.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Schmitgen, A. [GMD Forschungszentrum Informationstechnik GmbH-FIT, Sankt Augustin (Germany); Trantakis, C.; Winkler, D. [Klinik und Poliklinik fuer Neurochirurgie, Universitaetsklinikum Leipzig (Germany)

    2001-11-01

    The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion - requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions. (orig.) [German] Ziel dieser Arbeit waren die Realisierung und klinische Bewertung einer Bildfusion praeoperativer MRT- und fMRT-Bilder mit intraoperativen Datensaetzen eines interventionellen MRT-Systems am Beispiel neurochirurgischer Eingriffe. Ein vertikal offenes 0,5-T-MRT-System wurde mit einem erweiterten Navigationssystem ausgestattet, welches eine Integration zusaetzlicher Bildinformationen (Hochfeld-MRT, fMRT, CT) in die intraoperativ akquirierten Datensaetze erlaubt. Diese fusionierten Bilddaten wurden zur Interventionsplanung und multimodalen Navigation verwendet. Bisher wurde das System bei insgesamt 70 neurochirurgischen Eingriffen eingesetzt, davon 13

  10. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  11. Accuracy of spiral CT and 3D reconstruction in the detection of acute pulmonary embolism - development of an animal model using porcine lungs and technical specimens. Development of an animal model using porcine lungs and technical specimens; Diagnostik der akuten Lungenembolie mittels Spiral-CT und 3D-Rekonstruktion. Entwicklung eines Tiermodells und technischer Probekoerper im Ex-vivo-Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ries, B.G. [Klinik und Poliklinik fuer Radiologie, Univ. Mainz (Germany); Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Kauczor, H.U.; Thelen, M. [Klinik und Poliklinik fuer Radiologie, Univ. Mainz (Germany); Konerding, M.A. [Anatomisches Inst., Mainz Univ (Germany)

    2001-02-01

    von Modellen zur Evaluierung der Spiral-CT und 3D-Rekonstruktion im Nachweis der akuten Lungenembolie (LE) im Ex-vivo-Experiment. Material und Methoden: Standardisierte kuenstliche Emboli definierter Groesse und Geometrie wurden in Schweinelungen eingebracht. Ausguesse der embolisierten Gefaessbaeume mit roentgenkontrastgebendem Kunstharz simulierten das CT-morphologische Vollbild einer Lungenembolie. Die Bilddaten wurden dreidimensional rekonstruiert und die Exaktheit der detektierten Emboluslokalisation durch Korrelation mit dem Originalpraeparat verifiziert. Messungen an technischen Probekoerpern mit eingeschlossenen Emboli definierter Groesse sollten die Messgenauigkeit der kombinierten Spiral-CT-/3D Rekonstruktion in Abhaengigkeit von deren Orientierung zur z-Achse und von der Rekonstruktionstechnik (standardisiert und kontrastadaptiert) aufzeigen. Ergebnisse: Fuer die Detektion und Lokalisation ergab sich eine Uebereinstimmung zwischen Spiral-CT-/3D-Rekonstruktion und dem Originalpraeparat von {proportional_to}91%. Die Messungen der technischen Probekoerper ergaben deutliche Abweichungen in Abhaengigkeit von der Groesse, der Orientierung zur z-Achse und der Rekonstruktionstechnik. Hierbei traten Ueberschaetzungen von bis zu 4 mm, Unterschaetzungen von bis zu 2,2 mm auf. Bei Praeparaten mit Hoehen von 14-26 mm traten Schwankungen in einer Groessenordnung von ca. {+-}1,5 mm ({proportional_to}6-11%) auf. Schlussfolgerung: Die vorgestellten Ex-vivo-Modelle sind zur Simulation der akuten Lungenembolie gut geeignet. Die Genauigkeit der Embolusdetektion wird durch Lokalisation, Groesse, Orientierung und Rekonstruktionstechnik beeinflusst. (orig.)

  12. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report; Bildgebende Diagnostik des Klippel-Feil-Syndroms: Konventionelle Roentgenaufnahmen, CT und MRT. Fallbericht

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schubeus, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Menzhausen, L. [Abt. fuer Psychiatrie, Urban Krankenhaus, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1993-12-31

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [Deutsch] Anhand von zwei Patienten mit Klippel-Feil-Syndrom Typ II werden typische radiologische Befunde des Missbildungssyndroms im Bereich der Halswirbelsaeule und des kraniozervikalen Ueberganges dargestellt. Neben den konventionellen HWS-Roentgenaufnahmen und den konventionellen Schichtaufnahmen, wurden bei beiden Patienten ein CT der HWS und bei einem Patienten zusaetzlich ein MRT durchgefuehrt. Die Ergebnisse und Befunde der verschiedenen Untersuchungsverfahren werden einander gegenuebergestellt. (orig.)

  13. Cine MRI of the temporomandibular joint in comparison to static MRI and axiography; Cine-MRT des Kiefergelenks im Vergleich zur konventionellen MRT und Achsiographie

    Energy Technology Data Exchange (ETDEWEB)

    Beer, A.; Rummeny, E.J. [Inst. fuer Roentgendiagnostik der Technischen Univ. Muenchen, Klinikum rechts der Isar (Germany); Kolk, A.; Neff, A. [Klinik und Poliklinik fuer Mund-Kiefer-Gesichtschirurgie der Technischen Univ. Muenchen, Klinikum rechts der Isar (Germany); Hof, N. [Abt. fuer Diagnostische und Interventionelle Radiologie/Nuklearmedizin, Krankenhaus Dritter Orden, Muenchen-Nymphenburg (Germany); Treumann, T. [Roentgeninstitut, Kantonshospital Luzern (Switzerland)

    2004-04-01

    Purpose: To evaluate Cine MRI (cMRI) of the temporomandibular joint in comparison to static MRI (sMRI) and axiography. Materials and Methods: In a prospective study with 57 healthy volunteers as well as 33 patients after temporomandibular joint (TMJ) surgery or with severe joint dysfunction, we measured the mobility of both condyle and disc as well as the sagittal angle of condylar inclination with sMRI and cMRI. Measurements and image analysis were performed by a radiologist and a maxillofacial surgeon in consensus. The results of axiography served as standard of reference. Result: Concerning the assessment of the discoligamentous complex, sMRI was superior to cMRI in the patient-group (sensitivity sMRI 85%, cMRI 76%), while no significant difference was found in the volunteer-group (sensitivity sMRI 97.4%, cMRI 98.3%). The results of cMRI and sMRI showed a highly significant correlation with each other, as well as with the axiographic reference tracings (r=0.90). The average mobility of the disc and condyle was 6% and 10% higher in sMRI compared to cMRI (p=0.001) and showed a slightly higher variance (0.043 vs. 0.038). Concerning the condylar inclination angle, both MRI-procedures had the best correlation (r=0.94) with each other and axiography. Conclusion: Real-time MRI of the TMJ is comparable to axiography in its accuracy and is a useful adjunct to conventional static MRI. (orig.) [German] Fragestellung: Evaluation der Cine-MRT (cMRT) des Kiefergelenks im Vergleich zur statischen MRT (sMRT) und Achsiographie. Material und Methode: Bei 57 Probanden und bei 33 Patienten nach operativem Gelenkeingriff oder mit klinischer Funktionsstoerung wurden die Kondylus- und Diskusmobilitaet sowie die horizontale Kondylenbahnneigung (HKN) in der sMRT und in der cMRT bestimmt. Die Auswertung erfolgte durch einen Radiologen und einen Mund-Kiefer-Gesichtschirurgen im Konsensus. Die Werte der Achsiographie dienten als Goldstandard. Ergebnisse: Bezueglich der Abgrenzbarkeit des

  14. Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors; Analyse der mehrphasigen 64-Zeilen-Multidetektor-Computertomographie zur praeoperativen angiographischen Evaluation potenzieller Lebendnierenspender

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D.; Andersen, K.; Kroepil, P.; Cohnen, M.; Moedder, U.; Jung, G. [Universitaetsklinikum Duesseldorf, Institut fuer Diagnostische Radiologie, Duesseldorf (Germany); Sandmann, W. [Universitaetsklinikum Duesseldorf, Klinik fuer Gefaesschirurgie und Nierentransplantation, Duesseldorf (Germany); Ivens, K. [Universitaetsklinikum Duesseldorf, Klinik fuer Nephrologie, Duesseldorf (Germany)

    2008-07-15

    Anatomical imaging and the ascertainment of any anomalies in the renal vessels and the ureters are essential in the planning of a kidney donation. The aim of the present study was to assess the value of 64-row multidetector CT in noninvasive examination of the renal vessels and ureters of potential living kidney donors. The evaluation embraced 63 living renal donors (LNS) who underwent preoperative CT examination from December 2004 to January 2007. The examinations were all carried out using a Somatom Sensation -Cardiac 64 (Siemens Medical Solutions, Germany). As well as CT angiography (CTA), a venous phase of the abdomen and a late phase after 15 min using low-dose technique were performed for CT urography (CTU). The radiological findings were compared with the surgical results, or with the angiograms in 2 cases. Sensitivity, specificity and both negative and positive predictive value were calculated. In the 63 (31 female, 32 male) donors CTA had a sensitivity of 100% in examination of the main and accessory renal arteries and of 98.3% when the venous and ureteric anatomy were assessed. The sensitivity of low-dose CTU was also 100%. The findings recorded in this study indicate that noninvasive preoperative planning with 64-row multidetector CTA and CTU is a reliable 'one-stop shopping' method of examination for potential living kidney donors. (orig.) [German] Die anatomische Darstellung und Erfassung moeglicher Anomalien der Nierengefaesse und Ureteren ist fuer die Planung einer Lebendnierenspende von essenzieller Bedeutung. Die vorliegende Untersuchung soll die Wertigkeit der nichtinvasiven Evaluation mit der 64-Zeilen-Multidetektor-CT untersuchen. In die Auswertung wurden 63 Lebendnierenspender (LNS) eingeschlossen, die im Zeitraum 12.2004 bis 01.2007 mit der CT praeoperativ untersucht wurden. Die Untersuchungen erfolgten mit einem Somatom-Sensation-Cardiac-64 (Siemens Medical Solutions, Deutschland). Neben einer CT-Angiographie (CTA) wurden eine

  15. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Detektion frueher pathologischer Veraenderungen. Standardverfahren der bildgebenden Lungendiagnostik sind die Computertomographie (CT) zur morphologischen Darstellung und die Perfusions-/Ventilationsszintigraphie bzw. ''single photon emission computed tomography'' (SPECT) zur funktionellen Diagnostik. Zur Darstellung der Lungenventilation stehen die MRT mit hyperpolarisierten Gasen, die O{sub 2}-verstaerkte MRT, die MRT mit fluorierten Gasen und die Fourier-Dekompositions-MRT (FD-MRT) zur Verfuegung. Zur Perfusionsbestimmung koennen die dynamische kontrastmittelverstaerkte MRT (DCE-MRT), das ''arterial spin labeling'' (ASL) und die FD-MRT verwendet werden. Bildgebende Verfahren erlauben einen genaueren Einblick in die Pathophysiologie der Lungenfunktion auf regionaler Ebene. Vorteile der MRT sind die fehlende Strahlenbelastung, welche die schonende Akquisition dynamischer Daten ermoeglicht sowie die Vielfalt der verfuegbaren Kontraste und damit zugaenglichen Parameter der Lungenfunktion. Ausreichende klinische Daten existieren nur fuer bestimmte Anwendungen der DCE-MRT. Fuer die uebrigen Verfahren gibt es lediglich Machbarkeitsstudien und Fallserien mit unterschiedlichem Umfang. Hyperpolarisierte Gase sind technisch bedingt nur eingeschraenkt in der Klinik anwendbar. Ein klinischer Einsatz der genannten Verfahren sollte mit Ausnahme der DCE-MRT nur innerhalb von Studien erfolgen. (orig.)

  16. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  17. Floating venous thrombi: diagnosis with spiral-CT-venography; Diagnose flottierender venoeser Thromben mittels Phlebo-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Gartenschlaeger, M. [Mainz Univ. (Germany). Klinik fuer Radiologie; Klose, K.J. [Univ. Marburg, Medizinisches Zentrum fuer Innere Medizin, Abt. Poliklinik (Germany); Schmidt, J.A. [Univ. Marburg, Medizinisches Zentrum fuer Radiologie, Abt. fuer Strahlendiagnostik (Germany)

    1996-05-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [Deutsch] Mittels lokaler Kontrastmittelapplikation in eine ipsilaterale Fussrueckenvene und Spiral-CT wurden 16 konsekutive Faelle konventionell phlebographisch gesicherter Phlebothrombose untersucht, zusaetzlich wurde die farbkodierte Doppler-Ultraschalluntersuchung durchgefuehrt. In der konventionellen Phlebographie waren 8/16 Thromben flottierend, die uebrigen 8/16 wandadhaerent. In der Spiral-CT zeigten sich Wandadhaerenzen in 15/16 Faellen; der nachgewiesene flottierende Thrombus stimmte mit der konventionellen Phlebographie ueberein. Im farbkodierten Doppler-Ultraschall erschienen die Thromben in 3/16 Faellen flottierend, darunter ein von der konventionellen Phlebographie abweichender Befund. Der Vergleich von konventioneller und CT-Phlebographie ergab eine komplette Uebereinstimmung fuer konventionell phlebographisch nachgewiesene Wandadhaerenz und eine signifikante Abweichung

  18. Clinical evaluation of female pelvic tumors. Application fields of integrated PET/MRI; Lokal- und Ganzkoerperdiagnostik weiblicher Beckentumore. Anwendungsfelder der integrierten PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, J.; Umutlu, L. [Universitaetsklinikum Essen, Institut fuer diagnostische und interventionelle Radiologie und Neuroradiologie, Essen (Germany)

    2016-07-15

    Integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) scanning has recently become established in clinical imaging. Various studies have demonstrated the great potential of this new hybrid imaging procedure for applications in the field of oncology and the diagnostics of inflammatory processes. With initial studies demonstrating the feasibility and high diagnostic potential of PET/MRI comparable to PET-computed tomography (CT), the focus of future studies should be on the identification of application fields with a potential diagnostic benefit of PET/MRI over other established diagnostic tools. Both MRI and PET/CT are widely used in the diagnostic algorithms for malignancies of the female pelvis. A simultaneous acquisition of PET and MRI data within a single examination provides complementary information which can be used for a more comprehensive evaluation of the primary tumor as well as for whole body staging. Therefore, the aim of this article is to outline potential clinical applications of integrated PET/MRI for the diagnostic work-up of primary or recurrent gynecological neoplasms of the female pelvis. (orig.) [German] Integrierte Positronenemissionstomographie-Magnetresonanztomographen (PET-MRT) stehen seit wenigen Jahren fuer die klinische Diagnostik zur Verfuegung. Diverse Arbeiten konnten bereits das grosse Potenzial dieser neuen hybriden Bildgebungsmodalitaet zur Anwendung in der onkologischen und inflammatorischen Diagnostik aufzeigen. Nachdem initiale Studien die Durchfuehrbarkeit und diagnostische Vergleichbarkeit der PET-MRT zur etablierten PET-Computertomographie (PET-CT) gezeigt haben, sollte fuer eine Implementierung in der Routinediagnostik der Fokus zukuenftiger Studien darin liegen, eindeutige Indikationen zu definieren, in denen die simultane PET-MRT-Bildgebung einen definitiven Vorteil verglichen mit den etablierten diagnostischen Verfahren bietet. Sowohl die MRT als auch die PET-CT finden bereits eine

  19. The potentials of spiral CT for detection of focal liver lesions; Moeglichkeiten der Spiral-CT zur Diagnostik fokaler Leberlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Helmberger, H. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kersting-Sommerhoff, B. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Lenz, M. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Kirsten, R. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany); Bautz, W. [Technische Univ. Muenchen, Klinikum rechts der Iser, Inst. fuer Roentgendiagnostik (Germany)

    1996-03-01

    Spiral CT currently is the modality of choice for all aspects of diagnostic evaluation of the liver. Optimal selection of treatment should be based inter alia on the findings obtained by spiral CT with arterial application of contrast medium, as for example S-CTA (primary liver tumors), or S-CTAP (secondary liver tumors). Ultrasonography is the major supplementing modality. In the near future, MR imaging applying liver-specific contrast-enhancing agents is expected to become an important competing technique, and further developments of interest in diagnostic imaging of the liver are in the offing: it is not yet known which technique will be the modality of choice at the onset of the 21st century. (orig.) [Deutsch] Die Spiral-CT ist zur Zeit das empfehlenswerte Verfahren fuer alle Fragen der Leberdiagnostik. Zur optimalen praetherapeutischen Beurteilung der Leber sollte die Spiral-CT mit arterieller Kontrastmittelapplikation als S-CTA (primaere Lebertumoren) bzw. S-CTAP (sekundaere Lebertumoren) durchgefuehrt werden. Der US kommt ein Stellenwert als ergaenzende Methode zu. In Zukunft wird die MRT mit leberspezifischen Kontrastmitteln ein konkurrierendes Verfahren zur Spiral-CT darstellen, wobei eine weitere interessante Entwicklung auf dem Gebiet der hepatischen Bildgebung zu erwarten ist: Das diagnostische Verfahren der Wahl fuer die Leber zu Beginn des 21. Jahrhunderts ist noch nicht definiert. (orig.)

  20. Cerebral activation studies by PET and fMRT, clinical relevance?; Zerebrale Aktivierungsstudien mit PET und fMRT, klinische Relevanz?

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, T. [Neurologische Klinik und Poliklinik, Klinikum Grosshadern, Muenchen Univ. (Germany)

    1997-03-01

    Cerebral activation studies by PET and fMRT will gain increasing clinical relevance for functional neuroanatomy (reading, speaking), localisation of largely unknown cortical functions (vestibular cortex), imaging of subjective complaints of functional impairments (pain, smell, memory), and documentation of neurological rehabilitation at neuronal level (regeneration, compensation, substitution, learning). (orig.) [Deutsch] Zerebrale Aktivierungsstudien mit PET und fMRT erlangen zunehmend klinische Bedeutung fuer die funktionelle Neuroanatomie einzelner und komplexer Hirnleistungen (Lesen, Sprechen), die Lokalisation bislang unzureichend erforschter Hirnfunktionen (vestibulaerer Kortex), die Objektivierung subjektiver Beschwerden und Funktionsausfaelle (Schmerz, Riechen, Gedaechtnis) und die Dokumentation neurologischer Rehabilitation auf neuronaler Ebene (Regeneration, Kompensation, Substitution, Lernen). (orig.)

  1. Evaluation of injuries of the upper cervical spine in a postmortem study with digital radiography, CT and MRI; Evaluation experimentell erzeugter Verletzungen der oberen Halswirbelsaeule mit digitaler Roentgentechnik, Computertomographie und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Herold, T.; Fischer, U.; Grabbe, E. [Goettingen Univ. (Germany). Abt. fuer Roentgendiagnostik; Fadjasch, G.; Saternus, K.S. [Goettingen Univ. (Germany). Abt. fuer Rechtsmedizin; Koebke, J. [Koeln Univ. (Germany). Anatomisches Inst.

    1999-12-01

    obere Halswirbelsaeulen-Praeparate wurden nach definiertem Rotationstrauma sowie nach Praeparation mittels digitaler Roentgentechnik (DIMA Soft P41, Fa. Feinfokus), mittels CT (CTi, High Speed, GE) in konventioneller und in Spiraltechnik (Kollimation 1 mm, Pitch 1.0) sowie mit Hilfe der MRT (Magnetom Vision Siemens) in 2D- und 3D-Technik untersucht. Ergebnisse: Die Praeparation zeigte 6 Wirbelkoerperfrakturen, 5 Densfrakturen, 1 Fraktur des vorderen Atlasbogens, 4 knoecherne Ausrisse an den okzipitalen Kondylen und 6 Laesionen der Ligg. alaria. Die digitale Praeparateradiographie dokumentierte alle Frakturen und die 4 knoechernen Ausrissfrakturen am Condylus occipitalis. In der CT konnten alle Frakturen und ligamentaeren Verletzungen erkannt werden. Die 2D MRT wies 9 Frakturen sicher und 3 fraglich nach; die 3D MRT zeigte 7 Frakturen sicher und 5 fraglich. Von den 4 Ausrissfrakturen konnten 2 mit der 2D MRT und 1 mit der 3D MRT nachgewiesen werden. Ligamentaere Verletzungen waren sicher in der 2D MRT in 2/6 Faellen und in der 3D MRT in 1 Fall zu erkennen. Diskussion: In postmortalen Studien zeigt die CT gegenueber der digitalen Radiographie und der MRT in der Detektion von Frakturen und ligamentaeren Verletzungen der oberen Halswirbelsaeule eine Ueberlegenheit, wobei diese Ergebnisse nur bedingt auf Patienten nach Hochgeschwindigkeitstrauma uebertragbar sind. (orig.)

  2. Determination of left ventricular heart volume by fast MRI in breath-hold technique: how different are quantitative ventricular angiography, quantitative MRI, and visual echocardiography?; Linksventrikulaere Herzvoluminabestimmung mittels schneller MRT in Atemanhaltetechnik: Wie unterschiedlich sind quantitativer Herzkatheter, quantitativer MRT und visuelle Echokardiographie?

    Energy Technology Data Exchange (ETDEWEB)

    Rominger, M.B.; Bachmann, G.F. [Giessen Univ. (Germany). Diagnostische Radiologie; Kerckhoff-Klinik GmbH, Bad Nauheim (Germany). Projektgruppe Magnetresonanztomographie; Pabst, W. [Giessen Univ. (Germany). Inst. fuer Medizinische Informatik; Ricken, W.W. [Kerckhoff-Klinik GmbH, Bad Nauheim (Germany). Projektgruppe Magnetresonanztomographie; Dinkel, H.P.; Rau, W.S. [Giessen Univ. (Germany). Diagnostische Radiologie

    2000-01-01

    Goal: Comparison of fast MRI, echocardiography (Echo), and ventricular angiography (Cath) in the assessment of left ventricular global function. Methods: Fast MRI in short axis plane, biplane Cath, and 2D Echo were performed in 62 patients [35 coronary artery diseases, 16 acquired valvular diseases (VD), 9 dilated cardiomyopathies (DCM), 1 congenital heart disease and 1 heart transplantation]. Enddiastolic (EDV), endsystolic (ESV), stroke volumes (SV), cardiac output (CO), and ejection fraction (EF) were compared in MRI and Cath. EF was visually estimated in 2D Echo by an experienced observer. Results: In comparison to MRI, Cath overestimated EF by 8.4%, and Echo underestimated EF by 5.6%. The limits of agreement between MRI and Cath in EF were {+-}23.8%, between MRI and Echo {+-}18%, and between Echo and Cath {+-}19.4%. Significant differences were found between Cath and MRI in EDV, SV, and CO, but not for ESV. The best agreement in EF was found in the group with DCM, the worst in the group with VD. Conclusion: Important systemic and random errors were found in the comparison of MRI, Echo, and Cath. For therapy decision and follow-up, the methods should not be exchanged unscrupulously. (orig.) [German] Ziel: Methodenvergleich von schneller Magnetresonanztomographie (MRT), Echokardiographie (Echo) und Herzkatheter (HK) in der Bestimmung linksventrikulaerer globaler Funktionsparameter. Material und Methoden: Bei 62 Patienten (35 koronare Herzerkrankungen, 16 Herzklappenvitien (KV), 9 idiopathische dilatative Kardiomyopathien (DCM), 1 kongenitale Herzerkrankung und 1 Herzktransplantation) wurde ein Methodenvergleich zwischen schneller Cine MRT im Kurzachsenschnitt, biplanarem HK und 2D Echo durchgefuehrt. Verglichen wurden in MRT und HK linksventrikulaeres enddiastolisches (EDV) und endsystolisches Volumen (ESV), Schlagvolumen (SV), Herzzeitvolumen (HZV) und Ejektionsfraktion (EF). In der Echo wurde die EF visuell durch einen erfahrenen Untersucher bestimmt

  3. MRT versus CT in the diagnosis of pneumonia. Evaluation of a T2-weighted utrafast turbo-spin-echo sequence (UTSE)

    International Nuclear Information System (INIS)

    Leutner, C.; Lutterbey, G.; Kuhl, C.K.; Flacke, S.; Schild, H.H.; Glasmacher, A.; Theisen, A.; Wardelmann, E.; Grohe, C.

    1999-01-01

    Purpose: To evaluate a T 2 -weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T 2 -weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR eff /T E /Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the image quality of the MRT was very good to good. Conclusions: MRT in the technique presented here is in most cases equal to CT for the detection of pneumonia. Diagnosis of pulmonary abscesses seems to be better with MRT. (orig.) [de

  4. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Krestan, C.; Czerny, C. [Abteilung fuer Osteologie, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria); Gstoettner, W. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Frankfurt (Germany); Franz, P. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Wien (Austria)

    2003-03-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [German] In dieser Arbeit wird die Rolle der hochaufloesenden Computertomographie (HRCT) und der Magnetresonanztomographie (MRT) zur Abklaerung prae- und postoperativ bedingter Komplikationen erworbener Cholesteatome beschrieben. Die Bildgebung wurde sowohl mit der HRCT als auch mit der MRT durchgefuehrt. Die HRCT und die MRT wurden in axialer und koronaler Ebene (auch

  5. PET-CT and PET-MRI of the prostate. From {sup 18}F-FDG to {sup 68}Ga-PSMA; PET-CT/-MRT der Prostata. Von {sup 18}F-FDG zu {sup 68}Ga-PSMA

    Energy Technology Data Exchange (ETDEWEB)

    Knorr, K.; Eiber, M.; Scheidhauer, K. [Technische Universitaet Muenchen, Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Maurer, T. [Technische Universitaet Muenchen, Urologische Klinik und Poliklinik, Klinikum rechts der Isar, Muenchen (Germany); Wester, H.J. [Technische Universitaet Muenchen, Pharmazeutische Radiochemie, Garching (Germany)

    2017-08-15

    Fluordesoxyglukose (FDG) ist wegen der biologischen Besonderheiten des Prostatakarzinoms nur bei entdifferenzierten Tumoren hilfreich. Radiopharmaka wie Cholin-Derivate, das beim Prostatakarzinom vermehrt in die Tumorzelle aufgenommen und in die Zellmembran eingebaut wird sowie in juengster Zeit die hochspezifischen Liganden fuer das prostataspezifische Membranantigen (PSMA) revolutionieren derzeit die Prostatakarzinombildgebung und das (Re-)Staging. {sup 68}Ga-markierte PSMA-Liganden fuer PET-CT und PET-MRT sind hochspezifische Tracer zur Primaerdiagnostik sowie zur Lokalisationsdiagnostik im biochemischen Rezidiv eines Prostatakarzinoms. Bei Risikopatienten, also Patienten mit Intermediate- und High-risk-Tumoren haben sie die cholinbasierte PET-CT weitgehend verdraengt, insbesondere auch bei sehr niedrigen PSA-Werten (prostataspezifisches Antigen) von <0,5 ng/ml in der Rezidivdiagnostik. Die Anwendung bei der Primaerdiagnostik als PET-MRT, auch in Kombination mit der multiparametrischen MRT (mpMR), ist vielversprechend bzgl. der Fruehdiagnostik und der bildfusionsgestuetzten Biopsie sowie zur Operations- und Bestrahlungsplanung. (orig.)

  6. Haemophilic arthropathy of the knee. Gd-DTPA enhanced MRT. Clinical and radiological correlation; Haemophile Arthropathie des Kniegelenkes. Gd-DTPA-verstaerkte MRT: klinische und roentgenologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. [Radiologische Universitaetsklinik, Bonn (Germany); Kunze, V. [Radiologische Universitaetsklinik, Bonn (Germany); Hamann, M. [Radiologische Universitaetsklinik, Bonn (Germany); Eickhoff, H. [Orthopaedische Klinik, Krankenhaus Troisdorf (Germany); Koch, W. [Orthopaedische Klinik, Krankenhaus Troisdorf (Germany); Oldenburg, J. [Inst. fuer Experimentelle Haematologie und Transfusionsmedizin, Bonn (Germany); Reiser, M. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Steudel, A. [Radiologische Universitaetsklinik, Bonn (Germany)

    1994-02-01

    17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRT before and after i.v. bolus injection of Gadolinium-DTPA (0,1 mmol/kg body weight). After contrast enhancement, synovial proliferations exhibited an increase of signal intensity (SI) of FFE and SE images of 47.7% and 37.4% respectively, whereas muscle and fatty tissue, tendons, bone marrow and joint effusion revealed only minor increase in SI. The gradient of signal intensity (ratio SI/time) of pannus was 39,6% min. Gd-DTPA enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.) [Deutsch] Es wurden 17 Patienten mit einer haemophilen Arthropathie der Kniegelenke mit der statischen und dynamischen MRT vor und nach i.v. Bolusgabe von Gadolinium-DTPA (0,1 mmol/kg KG) untersucht. Nach Kontrastmittelgabe konnte ein Anstieg der Signalintensitaet des Pannus von 37,4% auf SE- und von 47,7% auf FFE-Aufnahmen gemessen werden. Der Gradient des Signalintensitaetsanstieges (%/Zeit) lag fuer Pannus bei 39,6%/min. Die Kontrastmittelgabe steigerte die Abgrenzbarkeit des Pannus von Gelenkerguss und den Gelenkbinnenstrukturen. Begleitend durchgefuehrte klinische und roentgenologische Bewertungen des Schweregrades der Arthropathie korrelierten nicht mit dem Signalintensitaetsverhalten des Pannus nach Kontrastmittelgabe. (orig.)

  7. Magnetic resonance tomography and ultrasound in rheumatology; MRT und Sonographie in der Rheumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Lack, W. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Machold, K. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie; Graninger, W. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie

    1996-08-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [Deutsch] Technische Innovationen in Hard- und Software von Magnetresonanztomographie (MRT) und Sonographiegeraeten haben die bildgebende Diagnostik in der Rheumatologie massgeblich beeinflusst (Verbesserungen der Oberflaechenspulen mit hohen Gradientenfeldern, dedizierte Niederfeldgeraete, Softwareverbesserungen in Form von kuerzeren Aquisitionszeiten und Verfeinerungen in der Fettunterdrueckung, hoehere Transducerfrequenzen zwischen 7 und 15 Mhz, Powerdopplerverfahren). Fuer die klinische Anwendung bedeutet dies, dass MRT und Sonographie als bildgebende Zusatzverfahren nach der Anfertigung konventioneller Roentgenaufnahmen anzuwenden sind, wenn diese unauffaellige Resultate ergeben oder spezielle Fragen zur Schwere des Krankheitsprozesses bzw. von Folgeerscheinungen zu beantworten sind. Im besonderen betrifft dies den Nachweis der Frueharthritis, die Differentialdiagnose klinisch nicht klar einzuordnender Krankheitsbilder und die Bestimmung des

  8. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    151 konsekutive Patienten mit Verdacht auf Pankreastumor untersucht. Hydro-CT-Technik: Patientenlagerung in 30 RAO, Darmparalyse durch 40 mg Buscopan, Magen- und Duodenaldistension mittels 1,5 l Wasser oral, individualisierte Boluskinetik Spiral-CT mit 3 mm Inkrement, 6 mm Tischvorschub und 3 mm Rekonstruktion, 130 ml nichtionisches KM (5 ml/s). Folgende Punkte wurden festgehalten und bewertet: 1. Tumordetektion ja/nein; 2. Differenzierung eines festgestellten Tumors in maligne oder benigne an Hand festgelegter Kriterien; 3. computertomographische Differentialdiagnostik der Tumoren; 4. Beurteilung der Resektabilitaet. Bei positivem Tumornachweis wurde als Goldstandard die intraoperative und histologische Bewertung und bei negativem Tumornachweis eine 6 monatige tumorfreie Nachsorgeperiode festgelegt. Die Praevalenz einer Raumforderung des Pankreas betrug etwa 38% in der Gesamtgruppe. Dabei erreichte die Hydro-CT eine Gesamtgenauigkeit in der Tumordetektion von 97,4% bei einer Sensitivitaet von 100% und einer Spezifitaet von 95,9%. Bei der Differenzierung eines malignen versus eines benignen Tumors ergab sich eine Gesamtgenauigkeit von 89,7% bei einer Sensitivitaet von 92,5% und einer Spezifitaet von 83,3%. 58 Patienten wurden operiert. Die Gesamtgenauigkeit der Resektabilitaetsbeurteilung erreichte 95% bei einer Sensitivitaet von 90,5% und einer Spezifitaet von 100%. (orig./MG)

  9. Grading sacroiliitis with emphasis on MRI imaging; Grading der Sakroiliitis mit Betonung der MRT-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, A.G.; Egund, N. [The Department of Radiology R, Aarhus Kommunehospital (Denmark)

    2004-03-01

    Cross-sectional imaging techniques play a decisive role in identification, localization, and characterization of alterations in the sacroiliac joint during the early stage of seronegative spondylarthropathy (SpA). Although several studies showed that the diagnostic capabilities of MRI and CT are superior to those of conventional radiography, they have not yet become established and accepted as methods for evaluating the grade of ankylosing spondylitis (AS) in contrast to conventional radiography. The lack of acceptance for MRI and/or CT methods for evaluating and grading changes in the sacroiliac joint makes it difficult to include the results of these procedures in classifying the grade of SpA. Moreover, grading the changes in the sacroiliac joint in SpA with a method more sensitive than conventional radiography will be of prime importance in assessing treatment, e.g., the efficacy of new biological therapeutic agents directed against the tumor necrosis factor-alpha (TNF-{alpha}). An overview of the available grading methods is provided and MRI and CT techniques are presented. (orig.) [German] Schnittbildverfahren spielen bei der Identifizierung, Lokalisation und Charakterisierung von Veraenderungen des Sakroiliakalgelenks (SIG) im Fruehstadium der seronegativen Spondylarthropathie (SpA) eine entscheidende Rolle. Obwohl mehrere Studien zeigten, dass der diagnostische Wert der MRT und CT jenem der konventionellen Radiographie ueberlegen ist, hat sich das Schnittbildverfahren als Mittel zur Evaluierung des Grades der ankylosierenden Spondylitis (AS) im Gegensatz zur konventionellen Radiographie noch nicht etabliert und durchgesetzt. Dieses Fehlen eines akzeptierten MRT- und/oder CT-Verfahrens zur Evaluierung und zum Grading der Veraenderungen am SIG macht es schwierig, die Ergebnisse dieser Verfahren bei der Einstufung des Grades der AS-Veraenderungen und Erarbeitung von Diagnosekriterien fuer andere Formen der SpA einzubeziehen. Ausserdem wird das Grading der SIG

  10. MRI of interstitial lung diseases. What is possible?; MRT bei interstitiellen Lungenerkrankungen. Was ist moeglich

    Energy Technology Data Exchange (ETDEWEB)

    Biederer, J. [Kreisklinik Gross-Gerau, Radiologie Darmstadt, Gross-Gerau (Germany); Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Deutsches Zentrum fuer Lungenforschung (DZL), Translational Lung Research Center (TLRC) Heidelberg, Heidelberg (Germany); Thoraxklinik, Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany); Wielpuetz, M.O.; Jobst, B.J.; Dinkel, J. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Deutsches Zentrum fuer Lungenforschung (DZL), Translational Lung Research Center (TLRC) Heidelberg, Heidelberg (Germany); Thoraxklinik, Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany)

    2014-12-15

    Magnetic resonance imaging (MRI) of the lungs is becoming increasingly appreciated as a third diagnostic imaging modality besides chest x-ray and computed tomography (CT). Its value is well acknowledged for pediatric patients or for scientific use particularly when radiation exposure should be strictly avoided. However, the diagnosis of interstitial lung disease is the biggest challenge of all indications. The objective of this article is a summary of the current state of the art for diagnostic MRI of interstitial lung diseases. This article reflects the results of a current search of the literature and discusses them against the background of the authors own experience with lung MRI. Due to its lower spatial resolution and a higher susceptibility to artefacts MRI does not achieve the sensitivity of CT for the detection of small details for pattern recognition (e.g. fine reticulation and micronodules) but larger details (e.g. coarse fibrosis and honeycombing) can be clearly visualized. Moreover, it could be shown that MRI has the capability to add clinically valuable information on regional lung function (e.g. ventilation, perfusion and mechanical properties) and inflammation with native signal and contrast dynamics. In its present state MRI can be used for comprehensive cardiopulmonary imaging in patients with sarcoidosis or for follow-up of lung fibrosis after initial correlation with CT. Far more indications are expected when the capabilities of MRI for the assessment of regional lung function and activity of inflammation can be transferred into robust protocols for clinical use. (orig.) [German] Die MRT der Lunge entwickelt sich zu einer ernstzunehmenden dritten Saeule der Thoraxdiagnostik neben dem Thoraxroentgen und der Computertomographie (CT). Ihr Wert in der paediatrischen Lungendiagnostik oder fuer den wissenschaftlichen Einsatz, insbesondere wenn eine Strahlenexposition vermieden werden soll, ist unbestritten. Von allen Indikationen stellt die Diagnostik

  11. Pretherapeutic and posttherapeutic laryngeal imaging; Prae- und posttherapeutische Larynxbildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Becker, M.; Burkhardt, K.; Allal, A.S.; Dulguerov, P.; Ratib, O.; Becker, C.D. [Hopitaux Universitaires de Geneve, Abteilung fuer Hals-Nasen-Ohren-Radiologie, Geneve (Switzerland)

    2009-01-15

    Cross-sectional imaging with CT, MRI and more recently PET CT plays an indispensable complementary role to endoscopy in the pretherapeutic diagnostic and staging of laryngeal neoplasms and in the evaluation of the operated or irradiated larynx. Adequate interpretation of the CT, PET CT and MR images requires a thorough knowledge of the patterns of submucosal spread and familiarity with the diagnostic signs of neoplastic invasion as seen with each modality. In addition, one should be aware of the implications of imaging for staging and treatment. Both CT and MR imaging are highly sensitive for the detection of neoplastic invasion of the preepiglottic and paraglottic spaces, subglottic region and cartilage. The high negative predictive value of both CT and MRI allows a relatively reliable exclusion of neoplasm cartilage invasion. The specificity of both CT and MRI is, however, moderately high and both methods may, therefore, overestimate the extent of tumor spread. However, recent investigations have shown that the specificity of MRI may be significantly improved by using new diagnostic criteria which allow differentiation of tumor from peritumoral inflammation in many instances. Both cross-sectional imaging methods also significantly improve the pretherapeutic staging accuracy of laryngeal tumors if used in addition to clinical examination and endoscopic biopsy. In the presence of a submucosal mass, CT and MRI play a key role for the diagnosis, as they may characterize the lesion, reliably depict its submucosal extent and guide the endoscopist to perform deep biopsies which allow the definitive histological diagnosis. Cross-sectional imaging also plays a key role in the evaluation of laryngoceles, recurrent laryngeal nerve paralysis and fractures. (orig.) [German] Sowohl CT als auch MRT und neuerdings die PET-CT sind unentbehrliche Zusatzuntersuchungen zur Diagnostik und Stadieneinteilung von Tumoren des Larynx. Sie sind der klinischen Untersuchung (einschliesslich

  12. First clinical experience with extended planning and navigation in an interventional MRI unit; Erste klinische Erfahrungen mit einer erweiterten Eingriffsplanung und Navigation am interventionellen MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moche, M.; Schneider, J.P.; Schulz, T.; Voerkel, C.; Kahn, T.; Busse, H. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schmitgen, A.; Bublat, M. [Fraunhofer-Inst. fuer Angewandte Informationstechnik, St. Augustin (Germany); Trantakis, C. [Klinik und Poliklinik fuer Neurochirurgie, Universitaetsklinikum Leipzig (Germany); Bennek, J. [Klinik und Poliklinik fuer Kinderchirurgie, Univ. Leipzig (Germany)

    2004-07-01

    Purpose: To present an advanced concept for patient-based navigation and to report on our first clinical experience with interventions in the cranium, of soft-tissue structures (breast, liver) and in the musculoskeletal system. Materials and Methods: A PC-based navigation system was integrated into an existing interventional MRI environment. Intraoperatively acquired 3D data were used for interventional planning. The information content of these reference data was increased by integration of additional image modalities (e. g., fMRI, CT) and by color display of areas with early contrast media enhancement. Within 18 months, the system was used in 123 patients undergoing interventions in different anatomic regions (brain: 64, paranasal sinus: 9, breast: 20, liver: 17, bone: 9, muscle: 4). The mean duration of 64 brain interventions was compared that of 36 procedures using the scanner's standard navigation. Results: In contrast with the continuous scanning mode of the MR system (0.25 fps), the higher quality as well as the real time display (4 fps) of the MR images reconstructed from the 3D reference data allowed adequate hand-eye coordination. With our system, patient movement and tissue shifts could be immediately detected intraoperatively, and, in contrast to the standard procedure, navigation safely resumed after updating the reference data. The navigation system was characterized by good stability, efficient system integration and easy usability. Despite additional working steps still to be optimized, the duration of the image-guided brain tumor resections was not significantly longer. (orig.) [German] Ziel: Vorstellung eines erweiterten Konzepts zur patientenbasierten Navigation sowie erste klinische Bewertung der durchgefuehrten Massnahmen im Kopf, Weichteil- und muskuloskeletalen Bereich. Material und Methode: Ein PC-basiertes Navigationssystem wurde in eine vorhandene interventionelle MRT-Umgebung integriert. Intraoperativ akquirierte 3-D

  13. Combined PET/MRI in cerebral and paediatric diagnostics; Kombinierte PET/MRT-Diagnostik bei zerebralen und paediatrischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, T.; Vollmar, C.; Porn, U.; Schmid, R.; Dresel, S.; Leinsinger, G.; Schmid, I.; Winkler, P.; Fischer, S.; Hahn, K. [Klinik und Poliklinik fuer Nuklearmedizin, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2002-07-01

    The aim of this overview is presentation of MRI and PET as synergistic modalities for combined analysis of morphology and function. For operative planning in epilepsy surgery, definition of the epileptogenic focus based on functional PET diagnostics and morphological MRI is decisive. For staging and follow-up examinations in oncology, MRI should be complemented by PET for the assessment of tumor vitality. In paediatric oncology patients we could demonstrate a therapy relevant increase of sensitivity/specificity with combined PET/MRI in contrast to single modalities. In the brain, full spectrum of digital image registration and three-dimensional reconstruction should be used. In extracranial cases, image fusion is disturbing due to a partial loss of image information of single modalities by the fusion process. (orig.) [German] Ziel dieser Uebersicht ist die Darstellung der MRT und PET als synergistische Verfahren zur Analyse von Morphologie und Funktion. Zur Resektionsplanung im Rahmen der Epilepsiechirurgie ist die Definition des Epilepsiefokus anhand der funktionellen PET-Diagnostik und die exakte Kenntnis der zerebralen Morphologie aus der MRT ganz entscheidend. Im Rahmen des onkologischen Stagings und bei Verlaufskontrollen ist wegen der geringeren Spezifitaet der MRT die additive PET zur Beurteilung der Tumorvitalitaet erforderlich. Anhand eines paediatrisch-onkologischen Patientengutes konnten wir zeigen, dass mit der kombinierten PET/MRT-Diagnostik eine therapierelevante Steigerung der Sensitivitaet/Spezifitaet gegenueber den Einzeluntersuchungen moeglich ist. Bei zerebralen Fragestellungen sollte das gesamte Spektrum der digitalen Bildfusion mit direkter Ueberlagerung mehrerer Modalitaeten und anschliessender dreidimensionaler Rekonstruktion ausgeschoepft werden. Bei extrakraniellen Fragestellungen ist die direkte Bildueberlagerung eher hinderlich, da die Bildinformation der Einzelmodalitaeten durch die Fusion teilweise verloren geht. (orig.)

  14. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  15. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction; Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter

    Energy Technology Data Exchange (ETDEWEB)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E. [Abt. Roentgendiagnostik I, Georg-August-Univ. Goettingen (Germany); Merten, H.A. [Abt. fuer Mund-, Kiefer- und Gesichtschirurgie, Georg-August-Univ. Goettingen (Germany)

    2002-07-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [German] Zielsetzung: Verbesserung der Aufnahme- und Rekonstruktionsparameter in der Mehrschicht Spiral-CT (MSCT) zur Untersuchung des knoechernen Mittelgesichtes in verschiedenen Ebenen. Material und Methode: Ein anthropomorphes Schaedel-Phantom wurde in axialer Schichtfuehrung mit einem MSCT untersucht, wobei die Kollimation (1,25 - 2,5 mm), der Tischvorschubfaktor (Pitch 3 - 6) und der Roehrenstrom (20 - 200 mA) systematisch variiert wurden. Aus den Volumendatensaetzen wurden jeweils koronare und parasagittale Sekundaerreformationen mit unterschiedlichen

  16. Molecular imaging of head and neck cancers. Perspectives of PET/MRI; Molekulare Bildgebung bei Kopf-ï]¿Hals-Tumoren. Perspektive der PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Stumpp, P.; Kahn, T. [Universitaetsklinikum Leipzig AoeR, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Purz, S.; Sabri, O. [Universitaetsklinikum Leipzig, Klinik und Poliklinik fuer Nuklearmedizin, Leipzig (Germany)

    2016-07-15

    The {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG-PET/CT) procedure is a cornerstone in the diagnostics of head and neck cancers. Several years ago PET-magnetic resonance imaging (PET/MRI) also became available as an alternative hybrid multimodal imaging method. Does PET/MRI have advantages over PET/CT in the diagnostics of head and neck cancers ?The diagnostic accuracy of the standard imaging methods CT, MRI and PET/CT is depicted according to currently available meta-analyses and studies concerning the use of PET/MRI for these indications are summarized. In all studies published up to now PET/MRI did not show superiority regarding the diagnostic accuracy in head and neck cancers; however, there is some evidence that in the future PET/MRI can contribute to tumor characterization and possibly be used to predict tumor response to therapy with the use of multiparametric imaging. Currently, {sup 18}F-FDG-PET/CT is not outperformed by PET/MRI in the diagnostics of head and neck cancers. The additive value of PET/MRI due to the use of multiparametric imaging needs to be investigated in future research. (orig.) [German] Die {sup 18}F-Fluordesoxyglukose-Positronenemissionstomographie-Computertomographie ({sup 18}F-FDG-PET-CT) hat ihren festen Stellenwert in der Diagnostik von Kopf-Hals-Tumoren. Seit einigen Jahren ist die PET-MRT als weitere hybride Bildgebungsmodalitaet verfuegbar. Bringt die PET-MRT Fortschritte bei der Diagnostik von Kopf-Hals-Tumoren ?Darstellung der diagnostischen Genauigkeit der bisherigen Bildgebungsmethoden CT, MRT und PET-CT anhand von Metaanalysen und Zusammenfassung der bisherigen Publikationen zur PET-MRT auf diesem Gebiet. Die PET-MRT zeigt in allen bisherigen Studien keine Ueberlegenheit bzgl. der diagnostischen Genauigkeit von Kopf-Hals-Tumoren. Sie kann jedoch durch die multiparametrische Diagnostik perspektivisch Beitraege zur Tumorcharakterisierung und damit moeglicherweise Voraussagen zum

  17. MRI in cardiac sarcoidosis and amyloidosis; MRT bei kardialer Sarkoidose und Amyloidose

    Energy Technology Data Exchange (ETDEWEB)

    Bauner, K.U. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Wintersperger, B. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2013-01-15

    Sarcoidosis and amyloidosis are both multisystem disorders, which may involve the heart; however, isolated cardiac disease is rare. Diagnosis of cardiac sarcoidosis and amyloidosis is crucial because the patient prognosis is dependent on cardiac involvement and early treatment. Echocardiography is the first line imaging modality in the diagnostic work-up of both diseases, possibly giving hints towards the correct diagnosis. Besides myocardial biopsy and radionuclide studies cardiac magnetic resonance imaging (MRI) is routinely performed in patients suspect of having infiltrative cardiomyopathy. The T1 mapping procedure is currently being evaluated as a new technique for detection and quantification of global myocardial enhancement, as seen in cardiac amyloidosis. Sensitivities and specificities for detection of cardiac sarcoidosis and amyloidosis can be significantly improved by MRI, especially with late gadolinium enhancement (LGE) imaging. In cardiac sarcoidosis the use of LGE is outcome-related while in amyloidosis analysis of T1-mapping may be of prognostic value. If cardiac involvement in sarcoidosis or amyloidosis is suspected cardiac MRI including LGE should be performed for establishing the diagnosis. (orig.) [German] Die Sarkoidose und Amyloidose sind Multisystemerkrankungen, in deren Verlauf es zu einer kardialen Beteiligung kommen kann. Bildgebend wird als primaeres Verfahren die Echokardiographie eingesetzt. Zur weiteren Diagnostik wird neben der Biopsie und nuklearmedizinischen Verfahren v. a. die MRT herangezogen. Als neuere Technik zur Darstellung globaler diffuser Kontrastmittelanreicherungen, wie sie im Rahmen der Amyloidose vorkommen, wird z. Z. das T1-Mapping evaluiert. Durch den Einsatz der MRT, insbesondere des Late-Gadolinium-Enhancements (LGE), koennen die Sensitivitaet und Spezifitaet in der Diagnostik der kardialen Sarkoidose und Amyloidose entscheidend verbessert werden. Bei der Sarkoidose stellt das Vorhandensein eines LGE einen

  18. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  19. MRT of scaphoid pseudo-arthrosis using Gd-DTPA. Staging and clinical correlation; MRT der Skaphoidpseudarthrose mit Gd-DTPA. Stadieneinteilung und klinische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Beutel, F. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Wilhelm, K. [LMU Muenchen (Germany). Abt. fuer Handchirurgie; Tempka, A. [Freie Univ. Berlin (Germany). Klinik fuer Unfall- und Wiederherstellungschirurgie; Schedel, H. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Haas, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Felix, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik

    1994-11-01

    During a period of two years, 134 patients with pseudo-arthrosis of the scaphoid were examined by conventional radiography and by MRI in the course of a prospective study. The aim of the study was to define radiological staging using contrast enhanced MRI in order to improve the prognostic criteria. All MRI examinations were carried out with a 1.5 Tesla scanner (SP63) using a surface coil and T{sub 1} weighted spin echo sequences in sagittal and frontal projection and frontal FLASH T{sub 2}-sequences and axial spin echo T{sub 2} sequences. The T{sub 1} weighted SE sequences in frontal projection were carried out before and after iv contrast (0.1 mmol Gd-DTPA/kg KG). All sequences were compared with conventional radiographs and the operative findings. Eight patients in stage 0 showed high signal intensity of both fragments in T{sub 1} weighted SE sequences and at surgery there was good vascularisation. In 22 cases there was reduced signal intensity in at least one fragment (stage I). 45 patients with scaphoid pseudo-arthrosis showed complete signal loss but marked contrast uptake with still vital nuclei at surgery (stage II). In 22 patients, there was no increase in signal intensity after contrast and complete loss of vitality of the fragments at surgery. Staging was not possible in 37 patients because of previous operative intervention. The use of contrast enhanced MRI provides additional information compared with conventional radiography or plain MRI. (orig.) [Deutsch] Im Rahmen einer prospektiven Studie wurden in einem Zeitraum von 2 Jahren 134 Patienten mit einer Skaphoidpseudarthrose (SPA) vergleichend konventionell roentgenologisch und magnetresonanztomographisch untersucht. Ziel der Studie war die Erstellung einer klinisch radiologischen Stadieneinteilung mit Hilfe der kontrastverstaerkten MRT zur Verbesserung von Prognosekriterien. Alle MRT-Untersuchungen wurden an einem 1,5 Tesla-Geraet (SP63) mittels einer Oberflaechenspule unter Verwendung von T{sub 1

  20. CT and MRT in mediastinal and hilar masses. CT und MRT bei mediastinalen und hilaeren Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Kramer, J.; Stiglbauer, R.; Wimberger, D.; Imhof, H. (Vienna Univ. (Austria). Klinik fuer Radiodiagnostik Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Metz, V. (Vienna Univ. (Austria). 2. Chirurgische Klinik)

    1990-11-01

    Thirty-eight patients with mediastinal and/or hilar masses were imaged by computed tomography (CT) and magnetic resonance imaging (MRI). Results were analyzed retrospectively regarding the ability to demonstrate the masses, their number, size, definition, location and tissue characteristics. CT and MRI showed equivalent results in 32 cases; additional information was obtained in two patients by CT, in four patients by MRI. In view of the specific advantages and limitations of both CT and MRI we believed that in patients with mediastinal and/or hilar masses, contrast enhanced CT remains the procedure of choice after performing plain chest radiographs; in certain cases MRI will prove useful for further evaluation. (orig.).

  1. PET-CT for nuclear medicine diagnostics of multiple myeloma; PET-CT in der nuklearmedizinischen Diagnostik des multiplen Myeloms

    Energy Technology Data Exchange (ETDEWEB)

    Dimitrakopoulou-Strauss, A. [Deutsches Krebsforschungszentrum (DKFZ), Klinische Kooperationseinheit Nuklearmedizin, Heidelberg (Germany)

    2014-06-15

    Functional or morphofunctional imaging modalities are used in myeloma patients for the diagnosis and therapy management within research protocols. Despite new staging criteria, which take into account the viability of a myeloma lesion, positron emission tomography (PET) is not used routinely. The impact of PET is therefore open. The role of PET and PET computed tomography (PET-CT) for the diagnosis and therapy management is discussed. The use of PET with 18F-fluorodeoxyglucose (FDG) allows the measurement of viable myeloma lesions and correlates with the stage of disease. A negative FDG examination correlates with a better prognosis. Furthermore, the number of focal lesions as well as the whole functional volume of myeloma lesions in FDG have a prognostic impact. Several studies have demonstrated the impact of FDG for the assessment of therapy monitoring and show that FDG is an earlier indicator for therapy response as compared to magnetic resonance imaging (MRI). The CT component of the new hybrid systems allows the assessment of osteolytic lesions in CT and their viability in FDG. The combination of PET with an MRT scanner allows the simultaneous measurement of bone marrow infiltration, focal lesions and their viability. The use of modern hybrid scanners, such as PET-CT and PET-MRT facilitates the simultaneous measurement of viable myeloma lesions, osteolytic lesions and bone marrow infiltration in the whole body; therefore, it is expected that these imaging modalities will play a greater role both in diagnosis and therapy management. (orig.) [German] Funktionelle oder morphologisch-funktionelle bildgebende Verfahren werden in der Diagnostik und im Therapiemanagement des multiplen Myeloms (MM) primaer fuer wissenschaftliche Zwecke eingesetzt. Ein routinemaessiger klinischer Einsatz ist trotz neuer Stadieneinteilung nicht erfolgt. Die Wertigkeit der Positronenemissionstomographie (PET) ist noch offen. Die Rolle von PET und PET-CT fuer die Diagnostik und das

  2. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions; Ultraschallgestuetzte Bildfusion mittels CT und MRT. Klinische Bedeutung fuer die bildgebende und interventionelle Diagnostik von Leberlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Zengel, P. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Klinik fuer Hals-, Nasen- und Ohrenheilkunde, Muenchen (Germany)

    2012-01-15

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [German] Bei der Bildfusion von Ultraschall mit anderen schnittbildgebenden Verfahren (CT, MRT) handelt es sich um ein relativ neuartiges Verfahren, welches unter Studienbedingungen jedoch bereits erfolgreich eingesetzt wurde. In der folgenden Machbarkeitsstudie soll der Nutzen weiterfuehrender Anwendungen der sonographischen Bildfusion, dem so genannten Global-Positioning-System- (GPS-) und Needle-Tracking, untersucht werden. Dabei handelt es sich um Instrumente, die insbesondere die Diagnostik und das Staging (GPS-Tracking) bzw. die bioptische Abklaerung (Needle-Tracking) von Patienten mit fokalen Leberlaesionen erleichtern. In diesem Artikel werden das Prinzip und die Anwendungsmoeglichkeiten dieser neuen Techniken anhand konkreter Beispiele in einem Kollektiv von 20 Patienten mit fokalen Leberlaesionen vorgestellt und erlaeutert. (orig.)

  3. The diagnostic use of MRT in cases of suspected spondylitis; MRT-Differentialdiagnose bei Verdacht auf Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, K. [Inst. fuer Roentgendiagnostik, Klinikum rechts der Isar der Technischen Univ. Muenchen (Germany)

    1994-11-01

    In cases where MRT fails to reveal abscess formation or typical vertebral changes to confirm the preliminary diagnosis, further examinations are necessary to exclude diseases other than spondylitis. More remote possibilities like insufficiency fracture, rheumatic disorders and neoplasm can mostly be ruled out on the basis of conventional X-ray pictures. Conventional tomography and computed tomography should also be carried out in addition to MRT in the rare case of unconfirmed activated arthrosis or disc removal syndrome. In order to distinguish between infective and non-infective/reactive changes, contrast-enhanced repeat MRT following antibiotic treatment may be very helpful. (orig.) [Deutsch] Wenn bei einer Spondylitis ein dafuer beweisender Abszess oder eine typische Destruktion des Wirbelkoerpers nicht vorliegt, ist auch nach Durchfuehrung einer MRT oft eine differentialdiagnostische Abgrenzung gegenueber anderen Ursachen erforderlich. Ferner stehende Differentialdiagnosen wie Insuffizienzfraktur, rheumatische Erkrankungen und eine Neoplasie koennen mit den Moeglichkeiten des konventionellen Roentgenbildes meist ausgeschlossen werden. An die konventionelle- und Computertomographie sollte - auch nach Durchfuehrung der MRT - noch in unklaren Einzelfaellen von aktivierter Arthrose oder Postdisketomie-Syndrom gedacht werden. Eine gute differentialdiagnostische Moeglichkeit zur Unterscheidung zwischen einem Infekt und einem nicht infektioesen/reaktivem Geschehen ist die Wiederholungs-MRT mit KM-Applikation nach durchgefuehrter antibiotischer Behandlung. (orig.)

  4. Incidence and significance of small focal liver lesions on MRI; Haeufigkeit und Bedeutung von kleinen fokalen Leberlaesionen in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kreft, B.; Pauleit, D.; Bachmann, R.; Conrad, R.; Kraemer, A.; Schild, H.H. [Bonn Univ. (Germany). Radiologische Klinik

    2001-05-01

    Analysis of the frequency and significance of small focal liver lesions ({<=} 2 cm) detected on MRI in the presence or absence of a history of malignancy. Methods: 628 MRI examinations of the liver performed during 1994 - 1996 were evaluated. The inclusion criterion into the study was the detection of a focal liver lesion with a size {<=} 2 cm. The frequency, the size, the diagnostic proof, and the differential diagnosis of the focal liver lesions were analysed with regard to the patients history of a known malignant tumor. Results: Overall, 179 of the 628 patients (28.5%) had focal liver lesions {<=} 2 cm (n = 338). 58.9% of the lesions could be classified based upon follow-up studies by ultrasound, CT or MRI, or by biopsy. The remaining 41.1% of the lesions could not be classified due to the absence of follow-up examinations. 57.3% of all proven lesions were benign and 42.7% were malignant. A history of a malignant tumor was present in 76.7% of all patients with small liver lesions; however, lesions were benign in these patients in 50.6% of the cases. In patients with no known history of a malignancy, 75% of the lesions were benign and 25% were malignant. However, these malignant lesions were in 10/11 cases hepatocellular carcinomas in patients with liver cirrhosis. (orig.) [German] Analyse der Haeufigkeit und der Bedeutung von kleinen Leberlaesionen ({<=} 2 cm) in der MRT in Abhaengigkeit einer vorbestehenden Tumoranamnese. Methode: Es wurden insgesamt 628 MRT-Untersuchungen der Leber aus dem Zeitraum von 1994-1996 ausgewertet. Einschlusskriterium in die Studie war der Nachweis von Leberlaesionen mit einer Groe paragraph e {<=} 2 cm, wobei die Haeufigkeit, die Groe paragraph enverteilung, die Diagnosesicherung und die Differenzialdiagnose in Abhaengigkeit von der Anamnese einer Tumorerkrankung untersucht wurden. Ergebnisse: Insgesamt wiesen 179 der 628 Patienten (28,5%) fokale Leberlaesionen {<=} 2 cm (n = 338) auf. 58,9% der Laesionen konnten aufgrund von

  5. Magnetic resonance imaging of pulmonary perfusion. Technical requirements and diagnostic impact; MRT der Lungenperfusion. Technische Voraussetzungen und diagnostischer Stellenwert

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Buesing, K.; Schoenberg, S.O.; Fink, C. [Klinikum Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Mannheim (Germany); Ingrisch, M.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Campus Grosshadern, Muenchen (Germany)

    2009-08-15

    With technical improvements in gradient hardware and the implementation of innovative k-space sampling techniques, such as parallel imaging, the feasibility of pulmonary perfusion MRI could be demonstrated in several studies. Dynamic contrast-enhanced 3D gradient echo sequences as used for time-resolved MR angiography have been established as the preferred pulse sequences for lung perfusion MRI. With these techniques perfusion of the entire lung can be visualized with a sufficiently high temporal and spatial resolution. In several trials in patients with acute pulmonary embolism, pulmonary hypertension and airway diseases, the clinical benefit and good correlation with perfusion scintigraphy have been demonstrated. The following review article describes the technical prerequisites, current post-processing techniques and the clinical indications for MR pulmonary perfusion imaging using MRI. (orig.) [German] Mit der Verfuegbarkeit leistungsfaehiger Gradientensysteme und schneller k-Raum-Akquisitionstechniken wie der parallelen Bildgebung konnten verschiedene Studien die Machbarkeit der Lungenperfusionsbildgebung in der MRT zeigen. In der Praxis haben sich dynamische kontrastverstaerkte 3D-Gradientenechosequenzen, wie sie fuer zeitaufgeloeste MR-Angiographien verwendet werden, fuer die Bildgebung der Lungenperfusion etabliert. Hiermit ist es moeglich, die Perfusion der gesamten Lunge mit ausreichend hoher zeitlicher und raeumlicher Aufloesung zu visualisieren. In mehren klinischen Studien konnte bei Patienten mit Lungenembolie, pulmonaler Hypertonie sowie Erkrankungen der Atemwege und des Lungenparenchyms der klinische Nutzen der Lungenperfusions-MRT und die gute Uebereinstimmung mit der Lungenperfusionsszintigraphie nachgewiesen werden. Der folgende Uebersichtsartikel beschreibt die technische Durchfuehrung, Bildnachverarbeitung und die klinischen Anwendungsgebiete der MRT zur Untersuchung der Lungenperfusion. (orig.)

  6. Magnetic resonance tomography and dental radiology (Dental-MRT); Die Magnetresonanztomographie in der Dentalradiologie (Dental-MRT)

    Energy Technology Data Exchange (ETDEWEB)

    Gahleitner, A. [Wien Univ. (Austria). Abt. fuer Osteologie; Wien Univ. (Austria). Abt. fuer Orale Chirurgie; Solar, P.; Ertl, L. [Wien Univ. (Austria). Abt. fuer Orale Chirurgie; Nasel, C.; Homolka, P. [Wien Univ. (Austria). Inst. fuer Biomedizinische Technik und Physik; Youssefzadeh, S.; Schick, S. [Wien Univ. (Austria). Abt. fuer Osteologie

    1999-12-01

    Purpose: To demonstrate the usefulness of Dental-MRT for imaging of anatomic and pathologic conditions of the mandible and maxilla. Methods: Seven healthy volunteers, 5 patients with pulpitis, 9 patients with dentigerous cysts, 5 patients after tooth transplantation and 12 patients with atrophic mandibles were evaluated. Studies of the jaws using axial T1- and T2-weighted gradient echo and spin echo sequences in 2D and 3D technique have been to performed. The acquired images were reconstructed with a standard dental software package on a workstation as panoramic and cross sectional views of the mandible or maxilla. Results: The entire maxilla and mandibula, teeth, dental pulp and the content of the mandibular canal were well depicted. Patients with inflammatory disease of the pulp chamber demonstrate bone marrow edema in the periapical region. Dentigerous cysts and their relation to the surrounding structures are clearly shown. After contrast media application marked enhancement of the dental pulp can be found. Conclusion: Dental-MRT provides a valuable tool for visualization and detection of dental diseases. (orig.) [German] Ziel dieses Beitrags ist die Vorstellung der Untersuchungsmoeglichkeiten des Ober- und Unterkiefers mittels Magnetresonanztomographie (Dental-MRT) und ihre Anwendung bei der Diagnose zahnmedizinischer Erkrankungen. Sieben gesunde Probanden, 5 Patienten mit Pulpitis, 9 Patienten mit dentogenen Zysten, 5 Patienten nach Zahntransplantationen und 12 Patienten mit atrophem Unterkiefer wurden untersucht. Axiale T1- und T2-gewichtete Gradientenecho- und Spinecho-Sequenzen in 2D und 3D-Technik wurden durchgefuehrt. Nach der Untersuchung wurden zusaetzliche Panoramaschnitte und orhoradiale Rekonstruktionen des Ober- und Unterkiefers, unter Verwendung einer gebraeuchlichen Dental-Software, angefertigt. Der gesamte Ober- oder Unterkiefer, Zaehne, Pulpa und der Inhalt des Mandibularkanals koennen gut dargestellt werden. Patienten mit einer Entzuendung der

  7. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  8. Imaging techniques and investigation protocols in pediatric emergency imaging; Aufnahmetechnik und Untersuchungsprotokolle beim paediatrischen Notfall

    Energy Technology Data Exchange (ETDEWEB)

    Scharitzer, M.; Hoermann, M.; Puig, S.; Prokop, M. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2002-03-01

    Paediatric emergencies demand a quick and efficient radiological investigation with special attention to specific adjustments related to patient age and radiation protection. Imaging modalities are improving rapidly and enable to diagnose childhood diseases and injuries more quickly, accurately and safely. This article provides an overview of imaging techniques adjusted to the age of the child and an overview of imaging strategies of common paediatric emergencies. Optimising the imaging parameters (digital radiography, different screen-film systems, exposure specifications) allows for substantial reduction of radiation dose. Spiral- and multislice-CT reduce scan time and enable a considerable reduction of radiation exposure if scanning parameters (pitch setting, tube current) are properly adjusted. MRI is still mainly used for neurological or spinal emergencies despite the advent of fast imaging sequences. The radiologist's task is to select an appropriate imaging strategy according to expected differential diagnosis and to adjust the imaging techniques to the individual patient. (orig.) [German] Das akut erkrankte Kind erfordert eine rasche radiologische Abklaerung mit besonderer Beruecksichtung der geaenderten Untersuchungsparameter bei gleichzeitig hohem Anspruch an den Strahlenschutz. Hochaufloesende Schallkoepfe, Multislice-CT und schnelle MR-Sequenzen erlauben eine bessere Anpassung der Untersuchungsmethoden an die Beduerfnisse in der Kinderradiologie. Ziel dieses Artikels ist eine Uebersicht ueber die verschiedenen radiologischen Untersuchungstechniken sowie deren Anpassung an kindliche Anforderungen und die Angabe von Untersuchungsalgorithmen der haeufigsten paediatrischen Notfaelle. In der Projektionsradiographie erlaubt die Optimierung der Aufnahmetechnik (digitale Radiographie, unterschiedliche Klassen von Film-Folien-Systemen, Belichtungsparameter) eine deutliche Reduktion der Strahlendosis bei diagnostisch ausreichender Qualitaet. Spiral- oder

  9. Temporomandibular Joint: MRT Diagnostics; Temporomandibulargelenk: MRT-Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Kress, B. [Universitaetsklinikum Heidelberg (Germany). Abteilung Neuroradiologie; Universitaetsklinikum Heidelberg (Germany). Neurologische Klinik; Schmitter, M. [Universitaetsklinikum Heidelberg (Germany). Poliklinik fuer zahnaerztliche Prothetik; Universitaetsklinikum Heidelberg (Germany). Abteilung Neuroradiologie

    2005-09-01

    MRI of the temporomandibular joint (TMJ) requires 1.5 T. The radiologist must be familiar with the anatomy and pathology of the TMJ. This review gives a description of MRI protocols for the TMJ, and MRI anatomy and pathology of the TMJ (open and closed mouth) by means of MR images and drawings. Diagnosing of the TMJ related diseases depends on standardized clinical and MR examinations. Therefore close interdisciplinary cooperation between dentist and radiologist is necessary. (orig.) [German] Magnetresonanztomographie bei Kiefergelenkbeschwerden erfordert neben guter technischer Ausstattung Kenntnisse der Anatomie und Pathologie des Kiefergelenks. Diese Uebersicht stellt neben MRT-Protokollen die Anatomie und die pathologischen Befunde des Kiefergelenks bei geoeffnetem und geschlossenem Mund anhand von Abbildungen und Graphiken systematisch dar. Bildgebende Diagnostik des Kiefergelenks gruendet sich auf eine standardisierte klinische und magnetresonanztomographische Untersuchung und erfordert eine enge interdisziplinaere Kooperation zwischen Zahnmedizin und Radiologie. (orig.)

  10. Imaging technique and current status of valvular heart disease using cardiac MRI; Untersuchungstechniken und Stellenwert der MRT bei der Diagnostik von Herzklappenerkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Lotz, J.; Sohns, J.M. [Universitaetsmedizin Goettingen, Georg-August-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Goettingen (Germany)

    2013-10-15

    The main indications for cardiac magnetic resonance imaging (MRI) in the evaluation of valvular heart disease are pathologies of the aortic and pulmonary valve. For mitral and tricuspid valve pathologies MRI is not the first line modality as these are usually well visualized by echocardiography. The advantages of MRI in valvular heart disease are a high reliability in the evaluation of ventricular volumes and function as well as the assessment of the perivalvular arterial or atrial structures. This reliability and the limitless access to any imaging plane partially compensates for the lower temporal and spatial resolution in comparison to echocardiography. In patients with congenital heart disease, cardiac MRI is established as a valuable diagnostic tool in daily clinical management, especially for the evaluation of pulmonary valve defects. Nevertheless, echocardiography remains the first-line diagnostic imaging tool for the foreseeable future. (orig.) [German] Die Untersuchung der Herzklappen in der MRT umfasst derzeit v. a. die Aorten- und Pulmonalisklappe. Pathologien der atrioventrikulaeren Klappen bilden demgegenueber nur selten die zentrale Fragestellung einer kardialen MRT-Untersuchung, da diese normalerweise einer echokardiographischen Untersuchung gut zugaenglich sind. Die Staerke der MRT ist die hohe Zuverlaessigkeit, mit der neben der Klappenmorphologie und -funktion die Funktionsparameter des jeweiligen Ventrikels und die Morphologie der nachgeschalteten Arterien bestimmt werden koennen. Dadurch kann die MRT die prinzipielle Schwaeche in der Orts- und Zeitaufloesung gegenueber der Echokardiographie teilweise kompensieren. Bei Patienten mit kongenitalen Herzvitien ist die MRT-basierte Klappendiagnostik fester Bestandteil des klinischen Managements. Das gilt besonders fuer die Evaluation der Pulmonalisklappe. Die Echokardiographie bleibt absehbar die Modalitaet der ersten Wahl fuer die Klappendiagnostik am Herzen. (orig.)

  11. Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Eibel, R.; Herzog, P.; Dietrich, O.; Reiser, M.; Schoenberg, S.O. [Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Rieger, C.; Ostermann, H. [Ludwig-Maximilians-Universitaet Muenchen (Germany). Abteilung fuer Haematologie/Onkologie, Klinikum Grosshadern

    2006-04-15

    Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. Especially for follow-up examinations in immunocompromised patients and, in some instances, for the staging of malignant diseases (malignant pleural mesothelioma, lung cancer, respectively), MRI is very promising and may contribute to a decrease in the radiation exposure of the patients. (orig.) [German] Die MRT des Lungenparenchyms ist wegen des extrem niedrigen Protonengehalts des Lungengewebes und den starken Grenzflaechen zwischen Luft und Parenchym prinzipiell sehr problematisch. Allerdings liegt bei pathologischen Lungengewebeveraenderungen eine andere Situation vor, da infolge von Oedem, Entzuendung bzw. Tumorwachstum der Protonengehalt erhoeht und die Grenzflaechen reduziert sind. Viele Erkrankungen der Lunge fuehren dazu, dass der Patient den Atem nicht lange anzuhalten vermag. Daher sind MRT-Pulssequenzen erforderlich, die eine Datenakquisition in wenigen Sekunden gestatten. Aus technischer Sicht werden die vom CT bekannten Submillimeterschichten vielleicht nie realisierbar sein, sodass sicher auch in Zukunft kleine

  12. MRI of pulmonary embolism; MRT der akuten Lungenembolie

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C.; Schoenberg, S.O. [Universitaetsklinikum Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie, Mannheim (Germany); Thieme, S.; Clevert, D.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ley, S. [Deutsches Krebsforschungszentrum Heidelberg, Abteilung Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Abteilung Paediatrische Radiologie, Heidelberg (Germany); Kauczor, H.U. [Deutsches Krebsforschungszentrum Heidelberg, Abteilung Radiologie, Heidelberg (Germany)

    2007-08-15

    Recent technical developments have substantially improved the potential of MRI for the diagnosis of pulmonary embolism. On the MR scanner side this includes the development of short magnets and dedicated whole-body MRI systems, which allow a comprehensive evaluation of pulmonary embolism and deep venous thrombosis in a single exam. The introduction of parallel imaging has substantially improved the spatial and temporal resolution of pulmonary MR angiography. By combining time-resolved pulmonary perfusion MRI with high-resolution pulmonary MRA a sensitivity and specificity of over 90% is achievable, which is comparable to the accuracy of CTA. Thus, for certain patient groups, such as patients with contraindications to iodinated contrast media and young women with a low clinical probability for pulmonary embolism, MRI can be considered as a first-line imaging tool for the assessment of pulmonary embolism. (orig.) [German] Technische Weiterentwicklungen der MRT haben deren Moeglichkeiten fuer die Diagnostik der Lungenembolie erheblich verbessert. Hierzu zaehlen auf Geraeteseite kuerzere Magneten sowie dedizierte Ganzkoerper-MRT-Systeme, die einerseits den Patientenzugang beguenstigen und andererseits eine Abklaerung einer potenziell zugrunde liegenden Venenthrombose in einer Untersuchung ermoeglichen. Auf Seite der Sequenztechnik hat die Einfuehrung der parallelen Bildgebung die raeumliche und zeitliche Aufloesung der MR-Angiographie (MRA) der Lunge deutlich verbessert. Durch eine Kombination zeitaufgeloester Messungen der Lungenperfusion und einer raeumlich hochaufgeloesten MRA kann fuer die Diagnostik der Lungenembolie eine Sensitivitaet und Spezifitaet von ueber 90% erzielt werden, was vergleichbar der Genauigkeit der CT-Angiographie (CTA) ist. Daher kann die MRT fuer bestimmte Personen, wie z. B. Patienten mit Kontraindikationen gegen jodhaltige Roentgenkontrastmittel (z. B. Hyperthyreose) oder juengere Frauen mit einer geringen klinischen Wahrscheinlichkeit fuer

  13. Combined functional and morphological imaging of sarcomas. Significance for diagnostics and therapy monitoring; Kombinierte funktionelle und morphologische Bildgebung bei Sarkomen. Stellenwert fuer Diagnostik und Therapiemonitoring

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, N.; Rist, C.; Reiser, M.F.; Berger, F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Schlemmer, M.; Issels, R. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Medizinische Klinik und Poliklinik III, Muenchen (Germany)

    2010-04-15

    . Ein Staging von Sarkompatienten einschliesslich der Erfassung von Lungenmetastasen ist damit in einem Untersuchungsgang moeglich. Die PET/CT wird bei Patienten mit primaer ossaeren und Weichteilsarkomen zur Diagnosestellung, zum Staging und Restaging, zum ''metabolischen Tumorgrading'', zur Biopsieplanung, zum Rezidivnachweis sowie zum Therapiemonitoring eingesetzt. Es konnte gezeigt werden, dass der FDG-Uptake des Tumors vor Therapie sowie die Aenderungen im FDG-Uptake nach Therapie signifikant mit der histopathologischen Response und dem Ueberleben der Patienten korrelieren. Damit ermoeglichen PET und PET/CT auch prognostische Aussagen. Neue Perspektiven der Hybridbildgebung mit der PET/CT ergeben sich durch die Etablierung neuer Radiotracer sowie durch die kombinierte Untersuchung von Tumormetabolismus und -perfusion. Die hochaufloesende MRT bleibt fuer die lokale Primaerdiagnostik sowie zur praeoperativen Planung mit Klaerung der exakten anatomischen Situation und moeglicher Infiltration vaskulaerer oder nervaler Strukturen weiter unverzichtbar. Die kontrastverstaerkte MRT ist ein wichtiges und gut verfuegbares Alternativverfahren zur Rezidivdiagnostik, ganz besonders fuer nichthypermetabole Tumoren. Dynamische, kontrastverstaerkte MRT-Sequenzen gewinnen fuer das Therapiemonitoring zunehmend an Bedeutung und sollten in prospektiven Studien mit der FDG-PET/CT korreliert werden. (orig.)

  14. Clinical use of MR imaging-guided interventions; Klinischer Einsatz der interventionellen MRT (iMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, T.; Schulz, T.; Moche, M.; Prothmann, S.; Schneider, J.P. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany)

    2003-07-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures. (orig.) [German] Die Integration diagnostischer und therapeutischer Massnahmen durch die MRT basiert auf der Kombination von exzellenter morphologischer und funktioneller Bildgebung. Das Spektrum MR-gefuehrter Eingriffe reicht von Biopsien, thermischen Therapieverfahren, vaskulaeren Applikationen bis hin zum intraoperativen Einsatz der MRT. Auf allen Gebieten konnten von verschiedenen Arbeitsgruppen ueberzeugende Ergebnisse sowohl im Bereich der Grundlagenentwicklung als auch bei klinischen Anwendungen vorgelegt werden. Es ist davon auszugehen, dass die interventionelle MRT einen hohen Stellenwert im Bereich der interventionellen Radiologie, der minimal-invasiven Therapie und der Ueberwachung von operativen Eingriffen erlangen wird. (orig.)

  15. MR imaging of the lateral collateral ligaments after ankle sprain; Aussenbandrupturen des Sprunggelenkes - Darstellung mit der MRT vor und nach funktioneller Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Grebe, P. [Klinik fuer Radiologie der Universitaetsklinik, Mainz (Germany); Kreitner, K.F. [Klinik fuer Radiologie der Universitaetsklinik, Mainz (Germany); Roeder, W. [Abt. fuer Chirurgie, St-Hildegardis-Krankenhaus, Mainz (Germany); Kersjes, W. [Klinik fuer Radiologie der Universitaetsklinik, Mainz (Germany); Hennes, R. [Abt. fuer Allgemein- und Unfallchirurgie, St. Josefshospital, Wiesbaden (Germany); Runkel, M. [Unfallchirurgische Klinik der Unversitaetsklinik, Mainz (Germany)

    1995-09-01

    35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. (orig./MG)

  16. Optimized detection and characterization of liver metastases. The role of current MRI contrast agents; Optimierte Detektion und Charakterisierung von Lebermetastasen. Leistungsvermoegen aktueller MRT-Kontrastmittel

    Energy Technology Data Exchange (ETDEWEB)

    Weinrich, J.M.; Well, L.; Bannas, P. [Universitaetsklinikum Hamburg-Eppendorf, Zentrum fuer Radiologie und Endoskopie, Klinik und Poliklinik fuer diagnostische und interventionelle Radiologie und Nuklearmedizin, Hamburg (Germany)

    2017-05-15

    Metastases are the most common malignant lesions of the liver. The presence of liver metastases is an important prognostic factor and is decisive for the further management, especially in patients with colorectal cancer. Detection and characterization of liver metastases as well as differentiation from benign lesions are of high importance and a daily challenge in clinical radiology. Contrast-enhanced magnetic resonance imaging (MRI) has the highest sensitivity in detecting liver metastases. The sensitivity of MRI has been further increased due to the development of liver-specific contrast agents. This article describes the role of extracellular and hepatobiliary contrast agents for the detection and characterization of liver metastases. Moreover, the current knowledge on safety, sequence optimization, transient severe dyspnea and the combination of hepatobiliary with intravascular contrast agents for liver imaging is discussed. (orig.) [German] Metastasen sind die haeufigsten malignen Leberlaesionen. Das Vorhandensein von Lebermetastasen ist entscheidend fuer die Prognose und weitere Therapieplanung von Tumorpatienten, insbesondere von Patienten mit kolorektalen Karzinomen. Die Detektion von Lebermetastasen sowie deren Unterscheidung von anderen Leberlaesionen sind daher von hoechster Bedeutung und stellen eine alltaegliche Herausforderung fuer den Radiologen dar. Die Bildgebung mit der hoechsten Sensitivitaet fuer die Detektion von Lebermetastasen stellt die dynamische kontrastmittelgestuetzte Magnetresonanztomographie (MRT) dar. Die bereits hohe Sensitivitaet der MRT wird durch den Einsatz leberspezifischer Kontrastmittel noch weiter gesteigert. Dieser Artikel beleuchtet die Rolle der aktuellen unspezifischen und leberspezifischen MRT-Kontrastmittel fuer die Detektion und Charakterisierung von Lebermetastasen. Weiterhin werden Erkenntnisse zur Sicherheit, Sequenzoptimierung, zu transienten Atemartefakten und zur Kombination von MRT-Kontrastmitteln fuer die

  17. Diagnosis of pancreatic tumors by spiral angio CT

    International Nuclear Information System (INIS)

    Miura, Kohi; Nakao, Norio; Takayasu, Yukio; Okawa, Tomohisa

    1995-01-01

    Spiral angio were performed with injection of 30 ml of contrast material at a rate of 1 ml/sec with a scan delay of 6 sec through catheter into the celiac artery while the blood flow of the superior mesenteric artery (SMA) was occluded by the inflated balloon catheter. Spiral CT scans were obtained using Somatom Plus (Siemens). Parameter for spiral CT were 24-sec acquisition time, 5 mm collimation, 5 mm/sec table incrementation. Reconstructions were performed every 5 mm. Pancreatic cancers were characteristically depicted with spiral angio CT as hypodensity relative to normal enhanced pancreatic parenchyma. On dynamic angio CT studies performed in pancreatic cancers, the area of cancer and normal parenchyma had maximum level of enhancement at 10-15 sec after injection of contrast material via catheter into the celiac, and there was no difference in enhancement between tumor and normal parenchyma. On the other hand, the lesions of cancer were revealed as hypodensity with spiral angio CT. In case of chronic pancreatitis, the enhancement of the entire pancreas obtained with spiral angio CT was homogeneous. Insulinoma in the tail of pancreas was detected by spiral angio CT but was not detected by both selective angiography and conventional CT. Three-dimensional (3-D) rendering spiral angio CT data shows the extent of vascular involvement by pancreatic cancer and provides useful information for surgical planning. Spiral angio CT is the most useful procedure for diagnosis of pancreatic tumor. (author)

  18. Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3D); Untersuchungen zur Bildqualitaet, Hochkontrastaufloesung und Dosis am Stamm- und Gliedmassenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)

    Energy Technology Data Exchange (ETDEWEB)

    Rock, C.; Kotsianos, D.; Linsenmaier, U. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Klinische Radiologie; Fischer, T. [Klinikum der Universitaet Muenchen, Muenchen (DE). Inst. fuer Klinische Radiologie] (and others)

    2002-02-01

    Purpose: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. Material and Methods: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3d). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). Results: Adequate image quality (mean score values 3-4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2-3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). Conclusion: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures. (orig.) [German] Zielsetzung: Evaluierung der 3D-CT-Bildgebung mit einem C-Bogen-basierten dedizierten CT-System (ISO-C-3D, Fa. Siemens) an Extremitaetengelenken und am Stammskelett. Methodik: 27 humane Leichenpraeparate der unteren und oberen Extremitaet sowie des Stammskeletts wurden am ISO-C-3D untersucht und die Bilddaten anhand eines Bildqualitaetsscores von 3 Untersuchern semiquantitativ evaluiert (Score 1: nicht

  19. Pulmonary embolism: spiral CT evaluation; Embolie pulmonaire: apport de la tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Senac, J.P.; Vernhet, H.; Bousquet, C.; Giron, J.; Pieuchot, P.; Durand, G.; Benezet, O.; Aubas, P. [Centre Hospitalier Universitaire, 34 - Montpellier (France)

    1995-06-01

    Purpose: Spiral computed tomography was compared retrospectively with digital substraction pulmonary angiography (PA) in 45 patients suspected of having acute or chronic pulmonary embolism. Materials and method : 45 patients in whom the presence of acute or chronic pulmonary embolism was suspected underwent examination by spiral CT and PA. Diagnosis of pulmonary embolism was based on the direct visualization of intraluminal clots. The study of the agreement between the two methods was based on the Kappa test. In 35 cases, pulmonary emboli were proved. Acute pulmonary emboli were present in 28 cases and chronic in 7 cases. Results: Spiral computed tomography represents an excellent way to detect acute pulmonary embolism. In the chronic form, spiral CT is better than PA to detect intraluminal clots. However, Spiral CT can fail to detect small emboli in the peripheral arterial bed. In the 10 patients without pulmonary embolism, the spiral CT proved diagnosis pulmonary oedema (n=3), lymphangi-carcinoma (n=4), pleural effusion (n=3). Conclusion: This study suggest that the spiral CT examination is accurate for diagnosis of pulmonary embolism specifically in case of suspected important embolism. The advantages of spiral CT are multiple (non invasive, wide diagnosis spectrum). However, may be a limitation to is use is insufficient distal thrombi detection. This eventuality (5 to 10% in the Pioped study) justify the practice of pulmonary angiography. Spiral CT improvements should reduce this insufficiency in the next future. (Authors). 16 refs., 4 figs., 3 tabs.

  20. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients; Wertigkeit der Mamma-MRT als Ergaenzung zu Mammographie und Sonographie bei Patientinnen mit erhoehtem Mammakarzinomrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2008-04-15

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [German] Ziele der Arbeit sind die inhaltliche Einfuehrung in das Thema Frueherkennung des Mammakarzinoms bei Patientinnen mit erhoehtem Risiko und eine systematische Analyse der Wertigkeit von MRT und anderen bildgebenden Verfahren in diesem Zusammenhang. Es wurde eine systematische Literaturrecherche ueber die letzten 3 Jahre durchgefuehrt. Dabei wurden Vergleichsstudien der verschiedenen bildgebenden Verfahren in der Mammadiagnostik beruecksichtigt, bei denen die bildgesteuerte Biopsie als Goldstandard angegeben wurde. Von allen bildgebenden Verfahren zeigt die Mamma-MRT bei Patientinnen mit familiaerem Risiko die hoechste Sensitivitaet und diagnostische Genauigkeit bei der Detektion des Mammakarzinoms. Fuer MRT, Mammographie und Sonographie werden Sensitivitaeten zwischen 71 und 100%, 0 und 78% sowie 13 und 65% angegeben. Die Mamma-MRT ist ein etabliertes Verfahren zum Screening von Risikopatientinnen. Uebereinstimmend wird der diagnostische Nutzen der Mamma-MRT als ergaenzendes Verfahren zu Mammographie

  1. Comparison of PET and fMRI activation patterns during declarative memory processes; Vergleich von PET und fMRT-Aktivierungsmustern waehrend deklarativer Gedaechtnisvorgaenge

    Energy Technology Data Exchange (ETDEWEB)

    Mottaghy, F.M.; Krause, B.J.; Schmidt, D.; Hautzel, H.; Mueller-Gaertner, H.-W. [Heinrich-Heine-Univ. Duesseldorf (Germany). Klinik fuer Nuklearmedizin; Forschungszentrum Juelich (DE). Klinik fuer Nuklearmedizin (KME); Herzog, H.; Shah, N.J. [Forschungszentrum Juelich (DE). Inst. fuer Medizin (IME); Halsband, U. [Albert-Ludwigs-Univ. Freiburg (Germany). Psychologisches Inst., Neuropsychologie

    2000-11-01

    Aim: In this study neuronal correlates of encoding and retrieval in paired association learning were compared using two different neuroimaging methods: Positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). Methods: 6 right-handed normal male volunteers took part in the study. Each subject underwent six 0-15-butanol PET scans and an fMRI study comprising four single epochs on a different day. The subjects had to learn and retrieve 12 word pairs which were visually presented (highly imaginable words, not semantically related). Results: Mean recall accuracy was 93% in the PET as well as in the fMRI experiment. During encoding and retrieval we found anterior cingulate cortex activation, and bilateral prefrontal cortex activation in both imaging modalities. Furthermore, we demonstrate the importance of the precuneus in episodic memory. With PET the results demonstrate frontopolar activations whereas fMRI fails to show activations in this area probably due to susceptibility artifacts. In fMRI we found additionally parahippocampal activation and due to the whole-brain coverage cerebellar activation during encoding. The distance between the center-of-mass activations in both modalities was 7.2{+-}6.5 mm. Conclusion: There is a preponderance of commonalities in the activation patterns yielded with fMRI and PET. However, there are also important differences. The decision to choose one or the other neuroimaging modality should among other aspects depend on the study design (single subject vs. group study) and the task of interest. (orig.) [German] Ziel: Vergleich der beiden Bildgebungsmethoden Positronen-Emissions-Tomographie (PET) und funktionelle Magnetresonanztomographie (fMRT) bei einer deklarativen Gedaechtnisaufgabe. Methoden: 6 Probanden wurden sowohl mit einer GE 4096+PET-Kamera als auch mit einem Siemens Vision MR-Tomographen waehrend einer deklarativen Gedaechtnisaufgabe untersucht. Die Gedaechtnisaufgabe bestand darin, 12 Wortpaare

  2. Evaluation of passive cardiomyoplasty using left- and right-ventricular volume measurements by EBCT and MRI in patients with chronic congestive heart failure; Evaluierung der passiven Kardiomyoplastie mittels links- und rechtsventrikulaerer EBCT- und MRT-Volumetrie bei Patienten mit chronischer Herzinsuffizienz

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, A.; Enzweiler, C.N.H.; Wiese, T.H.; Kivelitz, D.E.; Rogalla, P.; Hamm, B. [Inst. fuer Radiologie, Universitaetsklinikum Charite, Campus Charite Mitte, Humboldt Univ. zu Berlin (Germany); Hotz, H.; Dushe, S.; Konertz, W. [Klinik fuer Kardiovaskulaere Chirurgie, Universitaetsklinikum Charite, Campus Charite Mitte, Humboldt Univ. zu Berlin (Germany)

    2003-08-01

    Purpose: To evaluate the efficacy of passive cardiomyoplasty with the determination of biventricular volumes, global systolic function as well as left-ventricular muscle mass. Materials and Methods: In 19 patients with congestive heart failure of idiopathic or ischemic origin, a polyester mesh-graft was implanted around both ventricles for stabilization and functional support. Before and three months after surgery, 15 patients underwent EBCT and 4 patients with impaired renal function underwent MRI, for the evaluation of the volume and ejection fraction of both ventricles. Results: EBCT demonstrated a decrease from 385 to 310 ml in LV-EDV, from 312 to 242 ml in LV-ESV, from 209 to 160 ml in RV-EDV and from 149 to 87 ml in RV-ESV, and an increase from 20 to 26% in LV-EF and from 37 to 50% in RV-EF as well as a reduction of LV-MM from 300 to 274 g (p < 0.05 each). Similar results were obtained by MRI. Conclusion: Following passive cardiomyoplasty, EBCT and MRI revealed an improvement of the global systolic function as well as a reduction of biventricular volumes and left-ventricular muscle mass. (orig.) [German] Ziel: Evaluierung des Therapieerfolges der passiven Kardiomyoplastie durch Bestimmung der biventrikulaeren Volumina und global systolischen Funktion sowie der linksventrikulaeren Muskelmasse. Methoden: Bei 19 Patienten mit idiopathisch und ischaemisch bedingter Herzinsuffizienz erfolgte die Implantation eines Polyesternetzes um die Ventrikel zu deren Stabilisierung und funktioneller Unterstuetzung. Praeoperativ sowie drei Monate postoperativ wurden bei 15 Patienten durch EBCT und bei 4 Patienten mit eingeschraenkter Nierenfunktion durch MRT die Volumina und Ejektionsfraktion beider Ventrikel sowie die linksventrikulaere Muskelmasse bestimmt. Ergebnisse: Die EBCT zeigte eine Abnahme des LV-EDV von 385 auf 310 ml, des LV-ESV von 312 auf 242 ml, des RV-EDV von 209 auf 160 ml und des RV-ESV von 149 auf 87 ml, eine Zunahme der LV-EF von 20 auf 26% und der RV

  3. Speziation von Gadolinium-MRT-Kontrastmitteln in Umweltmatrizes

    OpenAIRE

    Lindner, Uwe

    2017-01-01

    Gd-Kontrastmittel werden in der Medizin für die Magnetresonanztomographie (MRT) benötigt, um einen besseren Bildkontrast zu erzielen. Nach der Anwendung gelangen diese Arzneimittel über das Abwasser in die Klärwerke und von dort in die jeweiligen anliegenden Oberflächengewässer. Somit wird es notwendig, den Verbleib der Gd-MRT-Kontrastmittel in der Umwelt zu verfolgen und aufzuklären. In dieser Arbeit werden für die Analyse von Umweltproben Methoden zur Speziesanalytik von Gd-Kontrastmitteln ...

  4. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    modern uroradiology. (orig.) [German] Die MR-Urographie (MRU) und CT-Urographie (CTU) bieten differenzierte Darstellungsmoeglichkeiten der ableitenden Harnwege, die mit der intravenoesen Roentgenurographie (IVU) nicht erreicht werden. Die traditionelle MR-urographische Untersuchungstechnik verwendet unabhaengig von der renalen Ausscheidungsfunktion stark T{sub 2}-gewichtete Turbo-Spinecho-Seuqenzen fuer eine statische Wasserbildgebung und ist hervorragend zur Darstellung gestauter Harnwege geeignet, selbst bei stummen Nieren. Demgegenueber spiegelt die T{sub 1}-gewichtete Ausscheidungs-MRU die Nierenfunktion und die Abflussverhaeltnisse der Harnwege wider. Hierzu wird ein nierengaengiges gadoliniumhaltiges MR Kontrastmittel intravenoes verabreicht und der gadoliniumhaltige Harn mit schnellen T{sub 1}-gewichteten 3D-Gradientenecho-Sequenzen abgebildet. Die Kombination mit niedrigdosiertem Furosemid (5-10 mg i.v.) ist der Schluessel fuer eine homogene endoluminale Gadoliniumverteilung und zur Unterdrueckung von stoerenden Suszeptibilitaetsartefakten (T{sub 2}*-Effekte) in Harn. Die T{sub 1}-MRU ermoeglicht eindrucksvolle Urogramme der nicht dilatierten und maessiggradig gestauten Harnwege, sofern die Nierenfunktion nicht zu stark gestoert ist. Die Mehrschicht-CT Urography (MS-CTU) ist wie die T{sub 1}-MRU ebenfalls eine Ausscheidungsurographie. Auch bei der MS-CTU gewaehrleistet die Kombination mit niedrigdosiertem Furosemid eine verbesserte Kontrastmittelverteilung ohne Notwendigkeit einer abdominellen Kompression. Der Einsatz der CTU wird durch die Strahlenexposition und die Nephrotoxizitaet von Roentgenkontrastmitteln limitiert. Fuer die MRU und MS-CTU ergeben sich in Kombination mit einer konventionellen MRT oder CT zahlreiche Anwendungsmoeglichkeiten, z.B. bei intrinsischen und extrinsischen Tumorerkrankungen. Ferner empfiehlt sich die MRU zur Beurteilung von Transplantatnieren und ersetz mittlerweile in der paediatrischen Uroradiologie das Roentgen-IVU. Die MS

  5. Diagnosis and differential diagnosis of Graves' orbitopathy in MRI; Diagnose und Differenzialdiagnose der endokrinen Orbitopathie in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Daubner, D.; Spieth, S.; Engellandt, K.; Kummer, R. von [Universitaetsklinikum Carl Gustav Carus, Technische Universitaet Dresden, Abteilung Neuroradiologie, Institut und Poliklinik fuer Radiologische Diagnostik, Dresden (Germany)

    2012-06-15

    Imaging of Graves' orbitopathy (GO) includes radiological and nuclear medicine procedures. Depending on the method used they provide information about the distribution and activity of the disease. Magnetic resonance imaging (MRI) is not only a helpful tool for making the diagnosis it also enables differentiation of the active and inactive forms of GO due to intramuscular edema. The modality is therefore appropriate to evaluate the disease activity and the course of therapy. The disease leads to the typical enlargement of the muscle bodies of the extraocular muscles. The inferior rectus, medial rectus and levator palpebrae muscles are mostly involved. Signal changes of the intraconal and extraconal fat tissue are possible and a bilateral manifestation is common. The differential diagnosis includes inflammatory diseases and tumors, of which orbital pseudotumor (idiopathic, unspecific orbital inflammation), ocular myositis and orbital lymphoma are the most important. The specific patterns (localization, involvement of orbital structures and signal changes) can be differentiated by MRI. (orig.) [German] Die Bildgebung der endokrinen Orbitopathie (EO) umfasst radiologische und nuklearmedizinische Verfahren, die je nach Methode Aussagen zur Verteilung und Aktivitaet der Erkrankung liefern. Die Magnetresonanztomographie (MRT) ist nicht nur zur Diagnosestellung hilfreich, sondern auch in der Lage, die aktive von der inaktiven Form anhand des intramuskulaeren Oedems zu unterscheiden. Das Verfahren eignet sich deshalb auch zur Aktivitaetsbeurteilung und zur Bewertung einer Therapie im Verlauf. Die Erkrankung fuehrt zu einer typischen Verdickung des Muskelbauchs der extraokulaeren Augenmuskeln, wobei die Mm. rectus inferior, rectus medialis und levator palpebrae am haeufigsten betroffen sind. Signalveraenderungen des intra- und extrakonalen Fettgewebes sind moeglich, und eine bilaterale Manifestation ist haeufig. Die Differenzialdiagnose umfasst neben anderen

  6. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  7. Magnetic resonance imaging (MRI) of liver and brain in haematologic-organic patients with fever of unknown origin; Magnetresonanztomographie (MRT) der Leber und des Gehirns bei haematologisch-onkologischen Patienten mit Fieber unbekannter Ursache

    Energy Technology Data Exchange (ETDEWEB)

    Heussel, C.P.; Kauczor, H.U.; Poguntke, M.; Schadmand-Fischer, S.; Mildenberger, P.; Thelen, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Heussel, G. [Mainz Univ. (Germany). 3. Medizinische Klinik und Poliklinik

    1998-08-01

    To examine the advantage of liver and brain MRI in clinically anomalous haematological patients with fever of unknown origin. Material and Methods: Twenty liver MRI (T{sub 2}-TSE, T{sub 2}-HASTE, T{sub 1}-FLASH{+-}Gd dynamic) and 16 brain MRI (T{sub 2}-TSE, FLAIR, T{sub 1}-TSE{+-}Gd) were performed searching for a focus of fever with a suspected organ system. Comparison with clinical follow-up. Results: suspected organ system. Comparison with clinical follow-up. Results: A focus was detected in 11/20 liver MRI. Candidiasis (n=3), mycobacteriosis (n=2), relapse of haematological disease (n=3), graft versus host disease (n=1), non-clarified (n=2). The remaining 9 cases with normal MRI were not suspicious of infectious hepatic disease during follo-wup. In brain MRI, 3/16 showed a focus (toxoplasmosis, aspergillosis, mastoiditis). Clinical indication for an infectious involvement of the brain was found in 4/16 cases 2--5 months after initially normal brain MRI. No suspicion of an infectious involvement of brain was present in the remaining 9/16 cases. Conclusion: In case of fever of unknown origin and suspicion of liver involvement, MRI of the liver should be performed due to data given in literature and its sensitivity of 100%. Because of the delayed detectability of cerebral manifestations, in cases of persisting suspicion even a previously normal MRI of the brain should be repeated. (orig.) [Deutsch] Untersuchung des Nutzens der MRT der Leber und des Gehirns bei klinisch auffaelligen haematologischen Patienten mit Fieber unbekannter Ursache. Material und Methoden: Es wurden 20 MRT der Leber (T{sub 2}-TSE, T{sub 2}-HASTE, T{sub 1}-FLASH{+-}Gd dynamisch) und 16 MRT des Gehirns (T{sub 2}-TSE, FLAIR, T{sub 1}-TSE{+-}Gd) zur Fokussuche bei Infektionsverdacht und Organhinweisen durchgefuehrt. Es erfolgte der Abgleich mit dem weiteren klinischen Verlauf. Ergebnisse: 11/20 MRT-Untersuchungen der Leber zeigten einen Herdbefund: Candidiasis (n=3), Mykobakteriose (n=2

  8. MR of the muskuloskeletal system: A review; MR-Tomographie (MRT) des Skeletts, der peripheren Weichteile und der Gelenke - aktuelle Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Bohndorf, K. [Zentralklinikum Augsburg (Germany). Klinik fuer Diagnostische und Neuroradiologie; Kretschmer, K.H. [Zentralklinikum Augsburg (Germany). Klinik fuer Diagnostische und Neuroradiologie

    1996-05-01

    The skeleton, the peripheral soft tissues, and the joints have become important indications to use MRI routinely. About 25-35% of daily examinations focus on these anatomic sites. Superior contrast resolution, the option of different imaging planes, and the unsurpassed visualization of bone marrow, fibrous and hyaline cartilage, ligaments, and tendons are the reasons for the overwhelming success of this imaging method. MRI often provides the direct way to diagnosis. More and more the so-called `step by step` approach to diagnosis by imaging methods is being abandoned in favor of the primary use of MRI. The present survey summarizes the main indications for MRI in the field of the musculoskeletal system, in adults as well as in children. Special topics like tumors, inflammation, ischemia, and trauma are discussed. Some anatomic sites like the carpal joint, the shoulder, and the knee are presented in more detail. (orig.) [Deutsch] Eine Vielzahl von Fragestellungen zu wesentlichen Indikationen der MR-Tomographie am Skelett, den peripheren Weichteilen und den Gelenken haben sich in der taeglichen Praxis entwickelt. Durchschnittlich 25-35% der taeglichen Untersuchungen betreffen diesen Themenkreis. Ueberlegene Kontrastaufloesung, die Darstellung in beliebig waehlbaren Ebenen und die unuebertroffene Visualisierung von Strukturen wie Knochenmark, fibroesem und hyalinem Knorpel, Ligamenten und Sehnen, sind die Ursache der raschen Verbreitung der Methode. Die MRT stellt haeufig den direkten Weg zur Diagnose dar und ersetzt zunehmend die sog. `Stufendiagnostik` und damit Methoden wie die Computertomographie, Arteriographie oder auch Skelettszintigraphie. In der vorliegenden Uebersicht werden wesentliche, heute als gesichert anzusehenden Anwendungsgebiete der MRT bei Kindern und Erwachsenen zusammengefasst. Die Arbeit gibt einen Ueberblick ueber spezielle Fragestellungen bei Tumoren, Entzuendungen, Ischaemie und traumatischen Fragestellungen. Eine Reihe von anatomischen

  9. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  10. The effect of pitch in multislice spiral/helical CT

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    2000-01-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  11. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  12. Imaging in syndrome complex diabetes mellitus. Current standards and future perspectives; Bildgebung im Syndromkomplex Diabetes mellitus. Stellenwert und Chancen

    Energy Technology Data Exchange (ETDEWEB)

    Hetterich, H.; Schafnitzel, A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Bamberg, F. [Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany)

    2015-04-01

    Diabetes mellitus is a highly prevalent multisystemic disorder with numerous potential complications and substantial socioeconomic consequences. In many cases, the patient history, physical examination and laboratory tests are not sufficient for a comprehensive evaluation of complicating disorders. Imaging modalities, such as sonography, computed tomography (CT) and magnetic resonance imaging (MRI) are of major significance in the evaluation of complicating disorders of diabetes according to current guidelines. Examples include assessment of coronary artery disease, peripheral artery disease, stroke and diabetic foot syndrome. Technical developments allow a substantial reduction in radiation dose and scan time in CT and MRI, respectively and could therefore justify a broader application in this patient population. In the future CT and MRI could also be used for the early detection of diabetic complications. Furthermore, they could also be used for risk stratification, e.g. measurement of hepatic fat content and evaluation of atherosclerosis in whole body MRI. Prior to widespread application of advanced imaging techniques in this patient population, improved outcomes with respect to survival, quality of life and cost-effectiveness need to be demonstrated. Diagnostic imaging modalities for the evaluation of the syndrome complex of diabetic disorders should be used according to the current guidelines but the use is predicted to increase given the high potential in this population. (orig.) [German] Diabetes mellitus ist eine hochpraevalente Multisystemerkrankung mit zahlreichen Komplikationen und bedeutenden soziooekonomischen Konsequenzen. Die Folgeerkrankungen koennen oft nicht abschliessend mittels Anamnese, koerperlicher Untersuchung und laborchemischen Verfahren evaluiert werden. Radiologische Verfahren wie die Sonographie, Computertomographie (CT) und Magnetresonanztomographie (MRT) haben gemaess verschiedener Leitlinien einen festen Stellenwert bei der

  13. Spiral CT manifestations of spherical pneumonia

    International Nuclear Information System (INIS)

    Li Xiaohong; Yang Hongwei; Xu Chunmin; Qin Xiu

    2008-01-01

    Objective: To explore the Spiral CT manifestations and differential diagnosis of spherical pneumonia. Methods: 18 cases of spherical pneumonia and 20 cases of peripheral pulmonary carcinoma were selected, both of them were confirmed by clinic and/or pathology. The SCT findings of both groups were compared retrospectively. Results: Main spiral CT findings of spherical pneumonia were showed as followings: square or triangular lesions adjacent to pleura; with irregular shape, blurry, slightly lobulated margin, sometimes with halo sign. Small inflammatory patches and intensified vascular markings around the lesions were seen. Lesions became smaller or vanished after short-term anti-inflammatory treatment. Conclusion: Spherical pneumonia showed some characteristics on Spiral CT scan, which are helpful in diagnosis and differential diagnosis of this disease. (authors)

  14. MRI of esophagus. N staging and more...; MRT des Oesophagus. N-Staging und mehr...

    Energy Technology Data Exchange (ETDEWEB)

    Krupski-Berdien, G. [Krankenhaus Reinbek St.-Adolf- Stift, Abteilung fuer diagnostische und interventionelle Radiologie, Reinbek (Germany)

    2007-02-15

    Esophageal disease is common. Fluoroscopy with or without fast cine-sequences is able to depict swallowing dynamics precisely and therefore is used in cases with swallowing disturbance, achalasia or diverticula etc. It is performed in addition to primary endoscopy. There is no evidence based indication for MRI in these settings as it is not to rule out postsurgical fistula and incompetence. Endoscopy and endosonography are gold standard for the depiction as well as staging of esophageal tumors hence differentiation of the esophageal wall layers and detection of suspicious lymph nodes is possible. And from both, biopsies may be taken. New techniques as OCT (optical coherence tomography) can demonstrate in situ carcinoma and therefore helps to decide for limited treatments as mucosectomy. For today multimodular treatment strategies in esophageal carcinoma the T-stage will lead to the treatment decision whereas the nodal-stage will give information about the prognosis. As a matter of fact endoscopy is unable to pass a stenosis esophageal tumor in up to 50% of the cases and will therefore not be able to give precise information on both T- and N-stage resulting in a good indication for MRI. Fetal MRI of the chest is a new topic in which MRI seems to be superior to ultrasonography. (orig.) [German] Erkrankungen des Oesophagus sind haeufig. Die Durchleuchtungsuntersuchung, ggf. mit schnellen Cinesequenzen, vermag exakt die Dynamik des Schluckakts darzustellen und wird regelhaft bei Fragestellungen wie ''Verschlucken'' und ''Globusgefuehl'', Verdacht auf Achalsie etc. sowie bei der Suche nach Divertikeln eingesetzt und ergaenzt die primaere Endoskopie. Die MRT besitzt hier derzeit keinen gesicherten Stellenwert - ebenso wie bei der haeufigsten Indikation zur Oesophagus-Breischluck-Untersuchung in der Klinik, der Frage nach Paravasation und Fistelung nach oesophagogastralen Eingriffen. Die exakten Lokalisation eines Oesophagustumors

  15. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  16. New procedures. Comprehensive staging of lung cancer by MRI; Neue Verfahren. Umfassendes Staging des Lungenkarzinoms mit der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Hintze, C. [Universitaetsklinikum Schleswig-Holstein, Campus Kiel, Klinik fuer Diagnostische Radiologie, Kiel (Germany); Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Dinkel, J. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Biederer, J. [Universitaetsklinikum Schleswig-Holstein, Campus Kiel, Klinik fuer Diagnostische Radiologie, Kiel (Germany); Heussel, C.P. [Thoraxklinik Heidelberg, Abteilung Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Puderbach, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (E010), Heidelberg (Germany); Thoraxklinik Heidelberg, Abteilung Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2010-08-15

    Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [German] Das Staging des Lungenkarzinoms nach dem TNM-System basiert auf der morphologischen Einschaetzung des Primarius, der Lymphknoten und Metastasen. Alle Aspekte dieser onkologisch wichtigen Beurteilung lassen sich mit der MRT erfassen. Pulmonale Rundherde sind ab der klinisch relevanten Groesse von 4-5 mm Durchmesser sicher erkennbar. Die Groesse der mediastinalen, hilaeren und supraklavikulaeren Lymphknoten kann in einem Untersuchungsgang bestimmt werden. In der koronaren Schichtfuehrung der dedizierten MRT der Lunge werden die Bereiche der bevorzugten Metastasierung in Nebennieren und weite Teile der Wirbelsaeule miterfasst. Durch eine gezielte Ganzkoerper-MRT als Suchmethode wird der letzte Teil des Stagings erfuellt. Die MRT bietet vielfaeltige Moeglichkeiten, zusaetzliche funktionelle, klinisch relevante Informationen innerhalb einer Untersuchung zu erheben. Im onkologischen Kontext sind die Perfusionsbildgebung der Lunge und die Bewegungsabschaetzung der Tumoren am bedeutendsten. Die funktionelle MRT der

  17. MRI for myocarditis; MRT bei Myokarditis

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, M.; Luecke, C.; Krieghoff, C.; Hildebrand, L.; Steiner, J.; Adam, J.; Grotthoff, M.; Lehmkuhl, L. [Herzzentrum, Universitaet Leipzig, Abteilung fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Lurz, P.; Eitel, I.; Thiele, H. [Herzzentrum, Universitaet Leipzig, Abteilung Kardiologie, Leipzig (Germany)

    2013-01-15

    Cardiovascular magnetic resonance imaging (CMRI) has become the primary tool for the non-invasive assessment in patients with suspected myocarditis, especially after exclusion of acute coronary syndrome (ACS) for the differential diagnosis. Various MRI parameters are available which have different accuracies. Volumetric and functional ventricular assessment and the occurrence of pericardial effusion alone demonstrate only a poor sensitivity and specificity. The calculation of the T2-ratio (edema assessment), the early or global relative myocardial enhancement (gRE) and the late gadolinium enhancement (LGE), which represents irreversibly injured myocardium, are more specific parameters. All MRI parameters demonstrate the best accuracy in infarct-like acute myocarditis, whereas in chronic myocarditis sensitivity and specificity are less accurate. Therefore, a multisequential (at least two out of three parameters are positive) approach is recommended. The assessment of the value of newer, more quantitative MRI sequences, such as T1 and T2-mapping is still under investigation. (orig.) [German] Die kardiale MRT stellt die primaere nichtinvasive bildgebende Modalitaet bei Verdacht auf Myokarditis dar, insbesondere auch nach Ausschluss eines akuten Koronarsyndroms (ACS) zur Differenzialdiagnose. Verschiedene MR-Parameter mit unterschiedlicher Wertigkeit stehen zur Verfuegung. Die Beurteilung der Volumetrie und Ventrikelfunktion weisen ebenso wie der Nachweis eines Perikardergusses alleine nur eine geringe Sensitivitaet und Spezifitaet auf. Die spezifischeren MRT-Inflammationsparameter stellen die T2-Ratio (Oedemnachweis), die fruehe Kontrastmittelanreicherung bzw. das globale relative Enhancement (gRE) und die spaete Kontrastmittelanreicherung, das so genannte Late-Gadolinium-Enhancement (LGE) als Zeichen eines irreversiblen Myokardschadens dar. Alle MR-Parameter zeigen die beste diagnostische Genauigkeit bei einer ''infarktaehnlichen'' akuten

  18. Kidney spiral CT, indications, realization, results

    International Nuclear Information System (INIS)

    Braunschweig, R.; Beilicke, M.; Hundt, W.; Breiteneder, T.; Reiser, M.

    1999-01-01

    The introduction of spiral computed tomography (spiral CT) has vastly enriched the methodologically diversity of computer-tomographic scans. It allows for the recording of different perfusion or excretion stages of the kidney parenchyma of the urine draining paths by carrying out long-distance, phase-identical multiple examinations of the retroperitoneum. The description of the findings which are characterized by their local and contrasts behavior is possible. The following report describes the indications and technological process of kidney spiral CT using kidney-typical intravenous contrast media. Special emphasis is put on the advantages and limits of multiple phase spiral CT. Decisive preconditions are: 1. Specific clinical query, 2. selection of the corresponding phase contrasts of the kidneys and uretra or bladder, 3. exact technical and temporal adjustment of the acquisition parameters. Scanning times are in the range of seconds. The overall examination can be carried out quick and without any major strain on the part of the patient. A sound proof and a general differentiation of focal kideny lesions can be derived from the acquired data. This is also true for kidneys and ureters findings. Bladder findings can be localized and differentiated according to stage. More than two 'spiral acquisitions' should be carried out with restraint taking exposure to radiation into account. Due to the sound registration of focal lesions, its capability of reproduction and its short-time examination, the spiral CT of the kidneys can be said to be the most effective current scanning method of the retroperitoneum following clinical examinations and sonography. (orig.) [de

  19. Spiral CT for evaluation of chest trauma

    International Nuclear Information System (INIS)

    Roehnert, W.; Weise, R.

    1997-01-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [de

  20. Sensitivity of MRI in detecting alveolar infiltrates. Experimental studies; Sensitivitaet der MRT fuer alveolaere Infiltrate. Experimentelle Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Biederer, J.; Busse, I.; Grimm, J.; Reuter, M.; Heller, M. [Kiel Univ. (Germany). Klinikum fuer Diagnostische Radiologie; Muhle, C. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Freitag, S. [Kiel Univ. (Germany). Inst. fuer Medizinische Informatik und Statistik

    2002-08-01

    detect pneumonia in patients. (orig.) [German] Zielsetzung: Eine experimentelle Studie zur Untersuchung des Signalverhaltens artifizieller alveolaerer Infiltrate mit T{sub 1}- und T{sub 2}-gewichteten MR-Sequenzen. Material und Methoden: 10 Lungen-Explantate von Schweinen wurden tracheal intubiert, in der kuenstlichen Thoraxhoehle eines Phantoms durch Unterdruck entfaltet und an einem klinischen Magnetresonanztomographen bei 1,5 T untersucht. Mit gezielter Instillation von 100-200 ml Gelatineloesung wurden alveolaere Infiltrate erzeugt und mit Gradientenecho- (2D-, 3D-GRE) und schnellen Spinechosequenzen (T{sub 2}-TSE, T{sub 2}-HASTE) dargestellt. Die Signalintensitaet des Lungenparenchyms nativ und mit Infiltrat wurde an repraesentativen Querschnitten erfasst. Zum Vergleich erfolgten Kontrollen mit Spiral-CT. Ergebnisse: Die instillierte Fluessigkeit simulierte alveolaere Infiltrate mit typischem Milchglasmuster im CT, wie es an Patienten mit Pneumonie oder ARDS beobachtet wird. Vor dem Versuch zeigten nur T{sub 2}-HASTE und T{sub 2}-TSE ein Lungenparenchymsignal (Signal/Rausch-Verhaeltnis von 3,62 bzw. 1,39). Nach Instillation von Fluessigkeit fand sich in diesen Sequenzen ein Signalanstieg von ca. 30% bei 100 ml (p<0,01) bzw. 60% bei 200 ml (p<0,01). Bei 2D-GRE betrug die Signalintensitaetszunahme 0,74% (p=0,32) nach 100 ml und 5,6% (p<0,01) nach 200 ml (fuer 3D-GRE 2,2% [p=0,02] bzw. 4,4% [p<0,01]). Die CT-Kontrollen zeigten fuer 100 ml eine Dichtezunahme um durchschnittlich 17 H.E. (p=0,02) und fuer 200 ml um 75 H.E. (p<0,01). Schlussfolgerungen: Mit T{sub 2}-gewichteten Sequenzen ist die MRT zur Darstellung artifizieller alveolaerer Infiltrate geeignet. (orig.)

  1. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  2. Anato-metabolic fusion of PET, CT and MRI images; Anatometabolische Bildfusion von PET, CT und MRT

    Energy Technology Data Exchange (ETDEWEB)

    Przetak, C.; Baum, R.P.; Niesen, A. [Zentralklinik Bad Berka (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Slomka, P. [University of Western Ontario, Toronto (Canada). Health Sciences Centre; Proeschild, A.; Leonhardi, J. [Zentralklinik Bad Berka (Germany). Inst. fuer bildgebende Diagnostik

    2000-12-01

    The fusion of cross-sectional images - especially in oncology - appears to be a very helpful tool to improve the diagnostic and therapeutic accuracy. Though many advantages exist, image fusion is applied routinely only in a few hospitals. To introduce image fusion as a common procedure, technical and logistical conditions have to be fulfilled which are related to long term archiving of digital data, data transfer and improvement of the available software in terms of usefulness and documentation. The accuracy of coregistration and the quality of image fusion has to be validated by further controlled studies. (orig.) [German] Zur Erhoehung der diagnostischen und therapeutischen Sicherheit ist die Fusion von Schnittbildern verschiedener tomographischer Verfahren insbesondere in der Onkologie sehr hilfreich. Trotz bestehender Vorteile hat die Bildfusion bisher nur in einzelnen Zentren Einzug in die nuklearmedizinische und radiologische Routinediagnostik gefunden. Um die Bildfusion allgemein einsetzen zu koennen, sind bestimmte technische und logistische Voraussetzungen notwendig. Dies betrifft die Langzeitarchivierung von diagitalen Daten, die Moeglichkeiten zur Datenuebertragung und die Weiterentwicklung der verfuegbaren Software, auch was den Bedienkomfort und die Dokumentation anbelangt. Zudem ist es notwendig, die Exaktheit der Koregistrierung und damit die Qualitaet der Bildfusion durch kontrollierte Studien zu validieren. (orig.)

  3. Neoplastic lesions of the temporomandibular joint (TMJ): diagnosis, differential diagnosis and intervention; Neoplasien des Temporomandibulargelenks (TMG). Diagnostik, Differenzialdiagnostik und Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Abolmaali, N.; Schedel, H.; Bergh, B. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Maeurer, J. [Radiologische Praxis am Prinzregentenplatz, Muenchen (Germany)

    2001-09-01

    Purpose. To evaluate the effectiveness of diagnostic and interventional radiological techniques for neoplastic lesions of the temporomandibular joint (TMJ). Material and methods. Modern diagnosis of the TMJ is based on the clinical use of conventional X-ray techniques, computed tomography (CT), magnetic resonance imaging (MRI) and interventional techniques like biopsies, vascular occlusion and ablation. Results. Conventional X-ray still forms the basic diagnostic procedure applied in open and closed mouth position. CT improves the diagnostic information and serves as the standard diagnostical instrument for cartaliganeous or osseous neoplastic lesions. MRI evaluates soft tissue infiltration in multiplanar techniques and high spatial resolution. Interventional vascular and ablative techniques improve the treatment of neoplastic disorders. (orig.) [German] Zielsetzung. Vorstellung der Wertigkeit bildgebender Verfahren fuer die diagnostische und interventionelle Radiologie des Temporomandibulargelenks (TMG). Material und Methodik. Die moderne Radiologie des TMG basiert auf dem Einsatz der konventionellen Roentgendiagnostik, der Computertomographie (CT) und der Magnetresonanztomographie (MRT), sowie interventioneller Verfahren wie der Biopsie, vaskulaerer Embolisationsverfahren und tumorablativer Verfahren. Ergebnisse. Als Basisdiagnostik dient die konventionelle Diagnostik in offener und geschlossener Mundposition der Erfassung von Funktionsstoerungen sowie ossaerer Destruktionen. Die CT erweitert das diagnostische Spektrum und verbessert die Differenzialdiagnostik fuer ossifizierende Prozesse. Der Einsatz der MRT erlaubt die Erfassung der Weichteilinfiltration sowie der Gelenkstrukturen. Vaskulaere interventionelle Verfahren dienen der praetherapeutischen Okklusion bzw. der palliativen Tumortherapie in Form der okklusiven Embolisation, der Chemoembolisation, oder auch der Tumorablation. (orig.)

  4. Magnetic resonance tomography (MRT) for lesions of the temporal lobes

    International Nuclear Information System (INIS)

    Schoerner, W.; Felix, R.; Meencke, H.J.; Freie Univ. Berlin; Freie Univ. Berlin

    1985-01-01

    A comparative study between magnetic resonance tomography (MRT) and CT was carried out in 16 patients with temporal lobe epilepsy. The MRT studies were performed on a 0.35 T Magnetom with T.1 modes in a coronal plane. MRT proved to the superior to CT. CT demonstrated a discrete temporal lobe lesion in three patients and MRT in four patients. In addition, unilateral atrophy of the temporal lobe was demonstrated by MRT in six cases; these could not be diagnosed by CT. The lack of artifacts near the skull base, the possibility of producing coronal sections and the excellent tissue differential of MRT provide the basis for improved diagnosis of lesions in the temporal lobes. (orig.) [de

  5. Anatomy of the skull base and the cranial nerves in slice imaging; Anatomie der Schaedelbasis und Hirnnerven in der Schnittbildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Bink, A.; Berkefeld, J.; Zanella, F. [Klinikum der Goethe-Universitaet Frankfurt, Institut fuer Neuroradiologie, Frankfurt am Main (Germany)

    2009-07-15

    Computed tomography (CT) and magnetic resonance imaging (MRI) are suitable methods for examination of the skull base. Whereas CT is used to evaluate mainly bone destruction e.g. for planning surgical therapy, MRI is used to show pathologies in the soft tissue and bone invasion. High resolution and thin slice thickness are indispensible for both modalities of skull base imaging. Detailed anatomical knowledge is necessary even for correct planning of the examination procedures. This knowledge is a requirement to be able to recognize and interpret pathologies. MRI is the method of choice for examining the cranial nerves. The total path of a cranial nerve can be visualized by choosing different sequences taking into account the tissue surrounding this cranial nerve. This article summarizes examination methods of the skull base in CT and MRI, gives a detailed description of the anatomy and illustrates it with image examples. (orig.) [German] Zur Untersuchung der Schaedelbasis sind sowohl die Computertomographie (CT) als auch Magnetresonanztomographie (MRT) geeignet. Waehrend mittels CT vorzugsweise die exakte knoecherne Ausbreitung von Pathologien z. B. zur operativen Therapieplanung erfasst werden, dient die MRT sowohl der Darstellung von Pathologien bzgl. ihrer Ausbreitung im Weichteilgewebe als auch dem Nachweis knoecherner Infiltration. Bei der Untersuchung der Schaedelbasis wird eine hochaufloesende Darstellung mit geringer Schichtdicke fuer beide Modalitaeten angestrebt. Die genaue Kenntnis der Anatomie ist bereits bei der Untersuchungsplanung notwendig. Sie ist zudem Voraussetzung fuer das Erkennen und die korrekte Interpretation von Pathologien. Die MRT ist die bildgebende Methode der Wahl zur Abklaerung von Pathologien der Hirnnerven. Dabei ist es durch gezielte Sequenzauswahl, die sich nach den die Hirnnerven umgebenen Strukturen richtet, moeglich, den gesamten Verlauf der Hirnnerven zu beurteilen. Dieser Artikel beschreibt die Untersuchung der Schaedelbasis

  6. Magnetic resonance imaging (MRI) of the TMJ: Influence on therapy and inter-observer agreement of two radiologists; Magnetresonanztomographie (MRT) des Kiefergelenkes: Einfluss auf Therapieentscheidung und Uebereinstimmung zweier Auswerter

    Energy Technology Data Exchange (ETDEWEB)

    Vahlensieck, M.; Okweschokwu, S. [Radiologie Haydnhaus, Bonn (Germany); Greven, M. [Medeco Zahnklinik, Bonn (Germany)

    2002-11-01

    Aim: To evaluate the influence of MRI of the temporomandibular joint on the therapeutic strategy in patients with craniomandibular disorders (internal derangement) and, furthermore, to analyze interobserver agreement for defined MRI criteria. Materials and Methods: Fifty-one unilateral and bilateral MRI examinations of 32 patients were enrolled. Therapeutic strategies before and after performance of the MRI were compared. Retrospectively, two radiologists independently analyzed the MR images for position of the disk, position of the condyle, signal intensity of the disk and bilaminar zone, osseous changes and several additional findings, using a check list. Agreement was tested by kappa statistics. Results: In 56% of the cases, changes of the therapeutic regimen were registered after MRI. Statistically significant agreement of the two observers was found for anterior position of the disk (kappa=0.44), transverse position of the disk (kappa=0.46) and position of the condyle (kappa=0.45). No significant agreement was found for signal intensity of the disk (kappa=0.14) or bilaminar zone (kappa=0.24), osseous changes (kappa=0.13) and the additional findings (kappa=0.29). Discussion: MRI has a measurable impact on the therapeutic approach to the internal derangement of the TMJ. The position of the disk and condyle can be reproducibly judged, while the signal intensity of the disk and bilaminar zone and the osseous changes are subject to wide observer variations. (orig.) [German] Zielsetzung: Es sollte der Einfluss der MRT des Kiefergelenkes auf die Therapieentscheidung untersucht werden. Des Weiteren sollten Uebereinstimmungen zweier unabhaengiger Radiologen in der Beurteilung von Kiefergelenk MRT anhand definierter Kriterien bestimmt werden. Material und Methoden: 51 MR-Untersuchungen des Kiefergelenkes wurden ausgewertet. Bei diesen Patienten wurde das urspruengliche mit dem Behandlungskonzept nach MRT verglichen. Alle MRT wurden von zwei Radiologen ausgewertet. Die

  7. Fetal MRI and ultrasound of congenital CNS anomalies; Fetales MRT und Ultraschall der angeborenen ZNS-Fehlbildungen

    Energy Technology Data Exchange (ETDEWEB)

    Pogledic, I.; Reith, W. [Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany); Meyberg-Solomayer, G. [Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Frauenheilkunde, Geburtsheilkunde und Reproduktionsmedizin, Homburg/Saar (Germany)

    2013-02-15

    In the last decade the newest technologies, fetal magnetic resonance imaging (MRI) and 3D ultrasound, have given an insight into the minute structures of the fetal brain. However, without knowledge of the basic developmental processes the imaging is futile. Knowledge of fetal neuroanatomy corresponding to the gestational week is necessary in order to recognize pathological structures. Furthermore, a modern neuroradiologist should be acquainted with the three steps in the formation of the cerebral cortex: proliferation, migration and differentiation of neurons in order to be in a position to suspect that there is a pathology and start recognizing and discovering the abnormalities. The fetal MRI has become an important complementary method to ultrasound especially in cortical malformations when confirmation of the prenatal diagnosis is needed and additional pathologies need to be diagnosed. In this manner these two methods help in parental counseling and treatment planning. (orig.) [German] Dank neuer Technologien (z. B. fetale MRT, 3-D-Sonographie) ist es moeglich, kleinste Hirnstrukturen darzustellen. Ohne Kenntnisse der grundlegenden Entwicklungsprozesse des Gehirns waere die Bildgebung jedoch sinnlos. Um pathologische Veraenderungen zu erkennen, ist es notwendig, den Stand der fetalen Neuroanatomie in der entsprechenden Schwangerschaftswoche zu kennen. Heutzutage sollte sich ein Neuroradiologe mit den 3 Schritten der kortikalen Entwicklung - Proliferation, Migration und Differenzierung der Neuronen - vertraut machen. Nur dann wird er in der Lage sein, pathologische Veraenderungen in Betracht zu ziehen, bzw. diese zu erkennen. Die fetale MRT ist besonders wichtig, ergaenzend zur zerebralen Sonographie, zur Diagnosebestaetigung bei kortikalen Veraenderungen und Nachweis weiterer Pathologien. In dieser Kombination ermoeglichen diese Methoden eine adaequate Beratung der Eltern und Planung der Behandlung. (orig.)

  8. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P. [Dept. of Radiology, St. Luc University Hospital, Brussels (Belgium)

    2001-11-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  9. Demonstration of pulmonary embolism with gadolinium-enhanced spiral CT

    International Nuclear Information System (INIS)

    Coche, E.E.; Hammer, F.D.; Goffette, P.P.

    2001-01-01

    The authors report a case of successful detection of pulmonary embolism using gadolinium-enhanced spiral CT (Gadodiamide, 0.4 mmol/kg, 2 ml/s, delay 18 s) in a 77-year-old woman, with previous allergy to iodinated contrast medium, and renal failure, who presented with pulmonary arterial hypertension. Doppler ultrasound of the lower limbs was first performed and revealed a deep venous thrombosis of the right lower limb. To establish if venous thrombosis was the cause of pulmonary hypertension and to confirm that pulmonary endarterectomy was not indicated in this situation, several imaging modalities were performed. Lung scintigraphy and MRI were non-diagnostic. Gadolinium-enhanced spiral CT demonstrated a large thrombus located proximally and in a segmental artery of the right lower lobe. This case illustrates the potential usefulness of gadolinium as alternative contrast agent with spiral CT to diagnose pulmonary embolism and elucidate the cause of pulmonary arterial hypertension in a patient with some contraindications for iodinated contrast medium injection. (orig.)

  10. Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer. A comparison between two modalities

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, Tiina; Visapaeae, Harri; Collan, Juhani; Kapanen, Mika; Kouri, Mauri; Tenhunen, Mikko; Saarilahti, Kauko [University of Helsinki and Helsinki University Hospital, Comprehensive Cancer Center, POB 180, Helsinki (Finland); Beule, Annette [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 180, Helsinki (Finland)

    2015-11-15

    To investigate the conversion of prostate cancer radiotherapy (RT) target definition from CT-based planning into an MRI-only-based planning procedure. Using the CT- and MRI-only-based RT planning protocols, 30 prostate cancer patients were imaged in the RT fixation position. Two physicians delineated the prostate in both CT and T2-weighted MRI images. The CT and MRI images were coregistered based on gold seeds and anatomic borders of the prostate. The uncertainty of the coregistration, as well as differences in target volumes and uncertainty of contour delineation were investigated. Conversion of margins and dose constraints from CT- to MRI-only-based treatment planning was assessed. On average, the uncertainty of image coregistration was 0.4 ± 0.5 mm (one standard deviation, SD), 0.9 ± 0.8 mm and 0.9 ± 0.9 mm in the lateral, anterior-posterior and base-apex direction, respectively. The average ratio of the prostate volume between CT and MRI was 1.20 ± 0.15 (one SD). Compared to the CT-based contours, the MRI-based contours were on average 2-7 mm smaller in the apex, 0-1 mm smaller in the rectal direction and 1-4 mm smaller elsewhere. When converting from a CT-based planning procedure to an MRI-based one, the overall planning target volumes (PTV) are prominently reduced only in the apex. The prostate margins and dose constraints can be retained by this conversion. (orig.) [German] Ziel unserer Studie war es, die Umstellung der Strahlentherapieplanung des Prostatakarzinoms von CT-gestuetzter in ausschliesslich MR-gestuetzte Zieldefinition zu untersuchen. Bei 30 Patienten mit Prostatakarzinom wurden eine CT und eine MRT unter Planungsbedingungen durchgefuehrt. Zwei Untersucher konturierten die Prostata in CT- und T2-gewichteten MR-Bildern. Mit Hilfe der Position von Goldstiften und der anatomischen Grenzen der Prostata wurden die CT- und MR-Bilder koregistriert. Es wurden die Genauigkeit der Koregistrierung sowie die Unterschiede der Zielvolumina und der

  11. Functional MRT in psychiatry and neurology; Funktionelle MRT in Psychiatrie und Neurologie

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, F. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Psychiatrie und Psychotherapie; Fink, G.R. (eds.) [Koeln Univ. (Germany). Klinik und Poliklinik fuer Neurologie

    2007-07-01

    Almost no other method has reach such an interest as the functional imaging in psychiatric and neurological science; it is fascinating to observe the brain at work. The fundamentals of functional magnetic resonance tomography (fMRT) and the interpretation of MRT images are explained; the state-of-the-art is discussed. The book is focussed on the functional imaging within psychiatry and neurology. The book contains 45 contributions within the following chapters: fundamentals, higher brain accomplishments, disease pattern, examinatory examples, perspectives.

  12. Frequency and doses of diagnostic and interventional X-ray applications. Trends between 2007 and 2014; Haeufigkeit und Dosis diagnostischer und interventioneller Roentgenanwendungen. Trends zwischen 2007 und 2014

    Energy Technology Data Exchange (ETDEWEB)

    Nekolla, E.A. [BfS - Bundesamt fuer Strahlenschutz, Abteilung Medizinischer und Beruflicher Strahlenschutz, Neuherberg (Germany); Schegerer, A.A.; Griebel, J.; Brix, G.

    2017-07-15

    der Patienten in diesem Anwendungsbereich eine hohe Bedeutung zukommt. Auswertung und Bewertung aktueller Daten zu Haeufigkeit und Dosis von Roentgenanwendungen sowie von zeitlichen Entwicklungen fuer die Jahre 2007 bis 2014. Die Haeufigkeit von Roentgenanwendungen wurde fuer den ambulanten Bereich ueber Gebuehrenziffern der erbrachten radiologischen Leistungen abgeschaetzt, fuer den stationaeren Bereich mithilfe von Krankenhausstatistiken. Repraesentative Werte fuer die effektive Dosis pro Roentgenanwendung wurden fuer die betrachteten Jahre ueberwiegend aus Daten der Aerztlichen Stellen ermittelt. Im Jahr 2014 wurden in Deutschland etwa 140 Mio. Roentgenanwendungen durchgefuehrt, hiervon etwa 40 % im zahnmedizinischen Bereich. Im Mittel erfolgten 2007-2014 nahezu konstant 1,7 Anwendungen pro Einwohner und Jahr. Neben der zahnmedizinischen Diagnostik wurden am haeufigsten konventionelle Untersuchungen des Skeletts und des Thorax durchgefuehrt. Die CT-Haeufigkeit nahm um ca. 40 % zu. Mit etwa 55 % war der Anstieg bei der MRT zwar noch deutlicher, jedoch wurden insgesamt noch immer mehr CT- als MRT-Untersuchungen durchgefuehrt. Die Dosiswerte pro Untersuchung nahmen trotz der in den letzten Jahren etablierten Methoden zur Dosisreduktion nur leicht ab. In der Konsequenz nahm die mittlere effektive Dosis pro Einwohner im Untersuchungszeitraum von knapp 1,4 auf 1,6 mSv zu - im Wesentlichen aufgrund der zunehmenden CT-Haeufigkeit. Die Prinzipien der Rechtfertigung und Optimierung von medizinischen Strahlenanwendungen sind - insbesondere bei CT-Untersuchungen - in jedem Einzelfall konsequent anzuwenden. (orig.)

  13. Comparative analysis between spiral CT and pathology of pulmonary nodules

    International Nuclear Information System (INIS)

    Wang Kaifu; Zhang Zhanqing

    2007-01-01

    Objective: To explore the value of spiral CT in the diagnosis of atypical pulmonary nodules. Methods: CT, clinic and histopathologic data of 72 patients with atypical pulmonary nodules confirmed by surgical resection in 41 cases and/or biopsy in 31 cases were retrospectively analyzed. Results: CT scans demonstrated slight lobulation in 34 cases, irregular margin in 50 cases, long speculate in 10 cases, air-bronchogram in 2 case, vacuole in 2 case. 38 pulmonary cancer, 22 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were diagnosed with spiral CT. However, 30 pulmonary cancer, 30 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were confirmed by histopathology. The overall accurate diagnostic rate of pulmonary cancer was 66.7% (20/30), pulmonary tuberculosis was 60%(18/30), pulmonary inflammatory pseudotumors was 16.7%(2/12). 40 cases were diagnosed correctly and 32 cases were misdiagnosed with CT in 72 cases of atypical pulmonary nodules. The misdiagnostic rate of CT was 44.4%. 10 cases of lung cancer were misdiagnosed, including 4 cases of tuberculosis (long speculate or irregular margin) and 6 cases of inflammatory pseudotumors (irregular margin or long speculate or air-bronchogram). 12 cases of tuberculosis were misdiagnosed, including 8 cases lung cancer (slight lobulation) and 4 cases of inflammatory pseudotumors (slight lobulation). 10 cases inflammatory pseudotumor were misdiagnosed as lung cancer (slight lobulation). Conclusion: Spiral CT was very useful in the localization and morphological describing, but difficult in qualitative diagnosing of atypical pulmonary nodules, exactly diagnosis was relied on surgery and biopsy. (authors)

  14. Principles of spiral CT: III. Quality assurance

    International Nuclear Information System (INIS)

    Suess, C.; Kalender, W.A.

    1998-01-01

    Since its introduction in 1989 spiral CT has gained wide clinical acceptance and meanwhile it covers a large range of CT applications. This new technology, however, has not yet been recognized and acknowledged in the national or international regulations on scanner quality assurance (QA) programs. The conventional QA procedures should be extended to check the distribution of resolution and noise within the image plane. Imaging performance in the axial direction constitutes one of the major advantages of spiral scanning. Therefore, the slice sensitivity profiles and the spatial and low-contrast resolution along the z-axis have to be assessed. The high demands on table feed accuracy require additional tests. We suggest phantoms and procedures to check and quantify these parameters. Thereby, we hope to support the ongoing discussion about spiral CT quality assurance. (orig.) [de

  15. Pulmonary granulomatous diseases and pulmonary manifestations of systemic granulomatous disease. Including tuberculosis and nontuberculous mycobacteriosis; Pulmonale granulomatoese Erkrankungen und pulmonale Manifestationen systemischer Granulomatosen. Inklusive Tuberkulose und nichttuberkuloese Mykobakteriosen

    Energy Technology Data Exchange (ETDEWEB)

    Piel, S. [Universitaet Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Thoraxklinik, Heidelberg (Germany); Kreuter, M.; Herth, F. [Universitaet Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Thoraxklinik, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kauczor, H.U. [Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Heussel, C.P. [Universitaet Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Thoraxklinik, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany)

    2016-10-15

    notwendig. Bei speziellen Fragestellungen spielen MRT und Positronenemissionstomographie (PET) eine Rolle, z. B. die Kardio-MRT bei Verdacht auf kardiale Beteiligung bei Sarkoidose oder die Cholin-PET-CT bei V. a. ein Narbenkarzinom bei Tuberkulose. Die Sensitivitaet der Duennschicht-CT ist bei den Granulomatosen sehr hoch. Insbesondere bei chronifizierten Verlaeufen mit Ausbildung fibrotischer Veraenderungen bzw. einer interstitiellen Lungenerkrankung ist eine Duennschicht-CT zur Differenzierung des Erkrankungsmusters wichtig. Ebenso spielt die Duennschicht-CT eine wichtige Rolle bei der Diagnostik von Komplikationen und Begleiterkrankungen, z. B. Malignomen. Die Methode gehoert inzwischen zur alltaeglichen klinischen Praxis. Bei klinischem Verdacht auf eine pulmonale Granulomatose und entsprechenden Hinweisen in der Thoraxuebersicht sind eine Duennschicht-CT und die interdisziplinaere Diskussion der Befunde zu empfehlen. (orig.)

  16. Cryotherapy of malignant tumors: MR imaging in comparison with pathological changes in mice; Kryotherapie maligner Tumoren: Untersuchungen mittels MRT im Tierexperiment und Vergleich mit morphologischen Veraenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Romaneehsen, B.; Anders, M.; Roehrl, B.; Hast, H.J.; Schiffer, I.; Neugebauer, B.; Teichmann, E.; Schreiber, W.G.; Thelen, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Hengstler, J.G. [Mainz Univ. (Germany). Inst. fuer Toxikologie

    2001-07-01

    (Lu1-Zellreihe) bei 15 Nacktmaeusen. Gruppe a (9 Tiere): Praeparation und histomorphologische Begutachtung (HE-Faerbung; TUNEL-Assay) von 7 Tieren nach 0-28 Tagen; Langzeitverlauf von zwei Tieren. Gruppe b: zusaetzliche MRT-Untersuchung von 6 Tieren vor sowie zu definierten Zeitintervallen nach der Kryotherapie mittels T{sub 1}- und T{sub 2}-gewichteter sowie kontrastverstaerkter T{sub 1}-gewichteter Spin-Echo-Sequenzen und anschliessende Praeparation. Vergleichende histologische Kontrolluntersuchung an unbehandelten Maeusen. Ergebnisse: Rasche Tumorverkleinerung nach Kryotherapie (50% innerhalb zwei Wochen) und narbige Ausheilung mit einer rezidivfreien Ueberlebenszeit von ueber 6 Monaten bei zwei Maeusen. In der nach der Kryotherapie durchgefuehrten MRT fehlende Kontrastmittelanreicherung im behandelten Gewebe mit stark anreicherndem Randsaum als Zeichen einer zentralen Stase und peripheren Hyperaemie. Histologisch zunehmende, nach 4 Tagen fast vollstaendige Nekrose des eingefrorenen Bezirkes sowie Apoptose-positive Kerne im TUNEL-Assay. (orig.)

  17. Three phase dynamic CT with double spiral CT: utility of determination of stomach cancer stage

    International Nuclear Information System (INIS)

    Jung, Min Ha; Kim, Hong In; Kim, Tae Hyung; Lee, Ki Yeol; Cho, June Il; Park, Cheol Min; Cha, In Ho

    1997-01-01

    To evaluate the utility of three phases of spiral CT in the diagnosis of stomach cancer. Between August 1994 and March 1995, thirty eight patients with stomach cancer, demonstrated on spiral CT, underwent surgery. Twenty-eight cases were advanced and ten were early. There were 27 men, and 11 women, and their average age was 52.8 years old (33-77). After ingestion of 600-700ml of water, 120-140ml of nonionic contrast material was injected intravenously. Spiral CT scanning was performed in 10mm slice thickness and of 10mm/sec table speed. Three phase image were obtained at 25sec (arterial phase), 60-65sec (venous phase) and 4min (equilibrium phase) after the start of bolus injection. On each phase, CT findings were compared with pathologic results, and tumor detectibility, depth of tumor invasion and lymph node metastasis was analysed. Thirty of the 38 carcinomas (79%) were detected on the arterial phase, 33 (81%) on the venous phase and 30 (79%) on the equilibrium phase. Depth of tumor invasion was measured accurately in 27 of 38 cases (71%) : T1-4/10 (40%), T2-8/11 (73%), T3-13/15 (87%), T4-2/2 (100%). We overstaged one case of T1 as T2 and two cases of T2 as T3, and understaged one case of T2 as T1 and two cases of T3 as T2. Among the 16 enlarged lymph nodes larger than 8mm, 13 cases were positive on pathologic examination and the sensitivity was 65%. With three-phase spiral CT scanning, we obtained 71% accuracy of depth of tumor invasion. The venous phase is most useful for tumor detection and for determining depth of tumor invasion and lymph node metastasis

  18. Diagnosing extracranial atherosclerotic diseases with spiral CT

    International Nuclear Information System (INIS)

    Moran, C.J.; Vannier, M.W.; Erickson, K.K.; Broderick, D.F.; Kido, D.K.; Yoffie, R.L.

    1991-01-01

    This paper reports that this discovery study was performed to determine whether extracranial carotid artery plaques could be diagnosed with a new CT technique (spiral CT) that allows nondistorted three-dimensional (3D) reconstructions in the z axis. Twenty carotid arteries were examined with spiral CT in normal volunteers and in patients suspected of having atherosclerotic plaques in the extracranial carotid arteries. The Somatom Plus CT table was advanced at a constant rate, the x-ray tube was continuously rotated, and 3D data were continuously acquired. Sixty milliliters of nonionic contrast medium was injected intravenously previous to and during the acquisition of data. The carotid bifurcations were identified in all patients. Planar images, similar to conventional intraarterial angiograms, were routinely produced from the volumetric CT data

  19. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  20. Dental magnetic resonance tomography (dental-MRT) as a method for imaging of the maxillo-mandibular bone; Dentale Magnetresonanztomographie (Dental-MRT) als Verfahren zur Darstellung des maxillomandibulaeren Zahnhalteapparates

    Energy Technology Data Exchange (ETDEWEB)

    Gahleitner, A.; Nasel, C.; Schick, S.; Dorffner, S.; Imhof, H.; Trattnig, S. [Wien Univ. (Austria). Abt. fuer Osteologie; Bernhart, T.; Mailath, G.; Watzek, G. [Wien Univ. (Austria). Abt. fuer Orale Chirurgie

    1998-10-01

    Purpose: To establish a new method for dental imaging using magnetic resonance tomography named Dental-MRT and to demonstrate its usefulness in diagnosing dentogen pathologies of the mandible and maxilla. Methods: Seven healthy volunteers, three patients with pulpitis, two patients with dentigerous cysts, two patients after tooth transplantation, and three patients with atrophic mandibles have been evaluated. Optimized axial T{sub 1}- and T{sub 2}-weighted gradient echo and spin echo sequences in 2D and 3D technique have been established to perform studies of the jaws. The acquired images were reconstructed with a standard dental software package on a workstation as panorama and cross-sectional views of the mandible or maxilla. Results: The entire maxillo-mandibular bone, teeth, dental pulp, and the content of the mandibular canal were well depicted. Patients with pulpitis demonstrate bone marrow edema in the periapical region. Dentigerous cysts and their relation to the surrounding structures are clearly shown. After contrast media administration marked enhancement of the dental pulp can be demonstrated. Conclusion: Dental-MRT promises to provide a new tool for visualization and detection of dental diseases. (orig.) [Deutsch] Ziel: Das Vorstellen der Dental-MRT als neue Methode zur Darstellung des Ober- und Unterkiefers und ihre Anwendung bei der Diagnose zahnmedizinischer Erkankungen. Methoden: 7 gesunde Probanden, drei Patienten mit Pulpitis, zwei Patienten mit odontogenen Zysten, zwei Patienten nach Zahntransplantationen und drei Patienten mit atrophem Unterkiefer wurden untersucht. Optimierte axiale T{sub 1}- und T{sub 2}-gewichtete Gradienten-Echo- und Spin-Echo-Sequenzen in 2D und 3D-Technik wurden angewandt. Nach der Untersuchung wurden Panoramaschnitte und dentale Rekonstruktionen des Ober- und Unterkiefers, unter Verwendung einer gebraeuchlichen Dental-Software, angefertigt. Ergebnisse: Der gesamte Kieferbereich, Zaehne, Pulpa und der Inhalt des

  1. MRI of the musculature in patients with myalgia - indications and imaging results; MRT der Muskulatur bei Myalgien - Indikationen und Bildbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Beese, M.S. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik; Winkler, G. [Universitaetsklinik Hamburg-Eppendorf (Germany). Neurologische Klinik; Maas, R. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik; Buechler, E. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik

    1996-05-01

    241 patients suffering from myalgic symptoms were examined by axial scans of the muscular system with T1w and STIR-sequences. All patients underwent a complete neuromuscular examination, which included an MRI guided muscle-biopsy of 203 patients. The images were retrospectively analysed as to the typical characteristics of differential diagnosis. In cases of idiopathic or bacterial/viral induced myositis, primary vasculitis, and rhabdomyolysis, edematous changes of the muscles could always be found. Abscesses were only found in bacterial myositis. In cases of poly- and dermatomyositis as well as inclusion-body-myositis, MRI showed a uniform distribution pattern with emphasis on the quadriceps muscles. In contrast to other neuromuscular diseases in bacterial induced myositis, focal myositis, and rhabdomyolysis a strong contrast agent enhancement was seen. All patients with myalgic syndromes without any other additional neuropathological findings and 86% of the patients suffering from polymyalgia rheumatica had normal MR-findings. MRI allows a correct exclusion of an inflammatory, tumorous, or rhabdomyolitic cause of a myalgia and leads to pathognomonic findings for these diseases. Diseases belonging to the group of endocrine, toxic, or metabolic myopathies might be normal in MRI. (orig./MG) [Deutsch] Bei 241 Patienten mit myalgischen Beschwerden wurden axiale Aufnahmen der Muskulatur mit T1w- und STIR-Sequenzen angefertigt. Bei allen Patienten wurde eine vollstaendige neuromuskulaere Untersuchung durchgefuehrt, die bei 203 Patienten eine MRT-gezielte Muskelbiopsie beinhaltete. Das Bildmaterial wurde retrospektiv hinsichtlich differentialdiagnostischer Charakteristika analysiert. Bei idiopathischen und erregerbedingten Myositiden, primaeren Vaskulitiden und bei Rhabdomyolysen bestanden ohne Ausnahme oedematoese Veraenderungen der Muskulatur. Abszessformationen wurden nur bei erregerbedingten Myositiden vorgefunden. Bei Poly- und Dermatomyositiden sowie

  2. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  3. Trauma of the lumbar spine and the thoracolumbar junction; Trauma der Lendenwirbelsaeule und des thorakolumbalen Uebergangs

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Harsch, N.; Kraus, C. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2016-08-15

    Anwendung der Spiral-CT koennen entscheidende Zusatzinformationen zur Morphe der Fraktur, damit zur Einschaetzung des Frakturtyps und letztlich zur Indikationsstellung einer ggf. operativen Therapie gewonnen werden. Die MRT ist hervorragend geeignet, wertvolle weiterfuehrende Informationen in Bezug auf Verletzungen der diskoligamentaeren Anteile der Wirbelsaeule zu geben. Speziell fuer die Verletzungen der Brust- und Lendenwirbelsaeule entwickelten Magerl et al. eine umfassende Klassifikation, die von der Arbeitsgemeinschaft fuer Osteosynthesefragen (AO) uebernommen wurde. Grundlage ist ein 2-Saeulen-Modell der Wirbelsaeule. Als Basis der Einteilung dienen bildgebend erkennbare pathomorphologische Charakteristika der Frakturen. Das Verletzungsmuster wird besonders beruecksichtigt. Beim Wirbelsaeulentrauma wird zwischen stabilen und instabilen Frakturen unterschieden. Die Behandlung des Wirbelsaeulenverletzten richtet sich nach dem Schweregrad der Gesamtverletzung. Neben einer adaequaten Erstversorgung am Unfallort sollte umgehend ein Trauma-CT durchgefuehrt werden, um keine Verletzungen zu uebersehen und eine schnelle Therapieentscheidung herbeizufuehren. (orig.)

  4. Possibilities of whole-body MRI for investigating musculoskeletal diseases; Moeglichkeiten der Ganzkoerper-MRT zur Diagnostik muskuloskelettaler Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P. [Klinikum der Eberhardt-Karls-Universitaet Tuebingen, Abteilung fuer Diagnostische Radiologie (Germany); Fischer, S. [Universitaetsklinikum Tuebingen, Abteilung fuer Strahlentherapie (Germany); Koetter, I. [Universitaetsklinikum Tuebingen, Abteilung fuer Haematoonkologie (Germany)

    2004-09-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [German] Dieser Beitrag gibt eine Uebersicht ueber die Moeglichkeiten und Limitationen der Ganzkoerper-MRT fuer die Diagnostik von Erkrankungen des muskuloskelettalen Systems. Es werden die Vor- und Nachteile der Ganzkoerper-MRT eroertert und ein Sequenzprotokoll fuer die muskuloskelettale Diagnostik vorgeschlagen. Auf Muskel-, Gelenk- und Knochenerkrankungen, bei denen der Einsatz der Ganzkoerper-MRT indiziert erscheint, dabei insbesondere Polymyositis, Muskeldystrophie, rheumatoide Arthritis, Spondylitis ankylosans, Polytrauma, Skelettmetastasen, Plasmozytom und das maligne Lymphom wird eingegangen. Die Ganzkoerper-MRT bietet neue Moeglichkeiten, insbesondere zur Ausbreitungsdiagnostik und Verlaufskontrolle multifokaler muskuloskelettaler Erkrankungen. Der klinische Nutzen dieser Methode fuer die einzelnen Erkrankungsentitaeten muss in weiteren Studien evaluiert werden. (orig.)

  5. Right-sided duplication of the inferior vena cava and the common iliac vein: hidden hinds in spiral-computed tomography; Rechtsseitige Dopplung der Vena cava inferior und Vena iliaca communis: Bildgebung mit der Spiral-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, D.R.; Friedrich, M. [Krankenhaus am Urban (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin; Andresen, R. [Staedtisches Krankenhaus Zehlendorf, Behring (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin

    1998-05-01

    Duplications of the inferior vena cava (IVC) are rare variants of the abdominal vessels and are normally located on both sides of the abdominal aorta. The rare case of a rightsided infrarenal duplication of the IVC with involvement of the common iliac vein is reported. Details of the embryology are presented for the understanding of this IVC variant. The spiral CT with multiplanar reconstructions makes it possible to define the vascular morphology and to differentiate it from lymphoma. (orig.) [Deutsch] Duplikaturen der Vena cava inferior (VCI) sind seltene meist bilateral der Aorta abdominalis gelegene abdominelle Gefaessvarianten. Der ungewoehnliche Fall einer rechtsseitigen infrarenalen Dopplung der VCI mit Beteiligung der Vena iliaca communis wird dargestellt. Auf der Embryologie wird, soweit fuer das Verstaendnis der vorliegenden VCI-Variante notwendig, eingegangen. Die Spiral-CT mit multiplanaren Rekonstruktionen erlaubt die morphologische Beschreibung der Gefaesssituation und die Differenzierung gegenueber Lymphomen. (orig.)

  6. Clinical value of MRI concerning dissection of the supraaortic vessels; Wertigkeit der MRT bei posttraumatischer Dissektion supraaortaler Gefaesse

    Energy Technology Data Exchange (ETDEWEB)

    Pauls, S.; Goerich, J.; Kraemer, S. [Abt. fuer Diagnostische Radiologie, Univ. Ulm (Germany); Hartwig, E. [Unfall- und Wiederherstellungschirurgie, Univ. Ulm (Germany)

    2002-03-01

    Purpose: Evaluation of the potential of MRI concerning dissection of the supra-aortic vessels after cervical trauma. Patients and methods: During the time period from August 1998 to February 2001, 148 patients with trauma were examined by means of MRI scan of the neck / cervical spine or skull concerning morphology of the cervical spine as well as the brain tissue. MRI sequences were weighted T{sub 1} and T{sub 2} before and after contrast medium in transverse and sagittal slices. Additional time of flight (TOF) sequences and contrast-enhanced angiography were acquired. The MRI images were examined by two experienced radiologists when tied consensus was reached. Results: 7 patients (4,7%) with a total of 9 dissections of the vertebral and/or internal carotid artery were found; diagnosis was done on TOF images, contrast enhances MR-angiography, transversal T{sub 1}- and T{sub 2}-weighted sequences as well as T{sub 1}-weighted images post-contrast medium. Therapy was changed accordingly in 4 cases and anticoagulation initiated. Conclusion: All patients with cervical injuries should be screened by MRI including MR-angiography, T{sub 1}-weighted images pre- and post-contrast agent to achieve a sure diagnosis concerning the precise size of the dissection. MRI has proven to be an excellent diagnostic tool for our patient group. (orig.) [German] Ziel: Beurteilung der Bedeutung der MRT bezueglich der Dissektionen supraaortaler Gefaesse im Rahmen cervicaler Traumata. Patienten und Methode: Im Zeitraum von August 1998 bis Februar 2001 wurden an unserer Klinik 148 Patienten mit Traumata zugewiesen, welche zur Abklaerung einer Gefuegestoerung der HWS bzw. Ausschluss einer Myelonaffektion eine MRT-Untersuchung des Halses / der HWS oder Schaedels erhielten. Es wurden jeweils T{sub 1}- und T{sub 2}-gewichtete Sequenzen in transversaler und sagittaler Schnittfuehrung vor und nach Kontrastmittelgabe angefertigt. Zusaetzlich wurden TOF-Sequenzen sowie kontrastunterstuetzte

  7. Staging of gastric adenocarcinoma using two-phase spiral CT: correlation with pathologic staging

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Lee, Dong Ho; Ko, Young Tae; Lim, Joo Won

    1998-01-01

    To correlate the preoperative staging of gastric adenocarcinoma using two-phase spiral CT with pathologic staging. One hundred and eighty patients with gastric cancers confirmed during surgery underwent two-phase spiral CT, and were evaluated retrospectively. CT scans were obtained in the prone position after ingestion of water. Scans were performed 35 and 80 seconds after the start of infusion of 120mL of non-ionic contrast material with the speed of 3mL/sec. Five mm collimation, 7mm/sec table feed and 5mm reconstruction interval were used. T-and N-stage were determined using spiral CT images, without knowledge of the pathologic results. Pathologic staging was later compared with CT staging. Pathologic T-stage was T1 in 70 cases(38.9%), T2 in 33(18.3%), T3 in 73(40.6%), and T4 in 4(2.2%). Type-I or IIa elevated lesions accouted for 10 of 70 T1 cases(14.3%) and flat or depressed lesions(type IIb, IIc, or III) for 60(85.7%). Pathologic N-stage was NO in 85 cases(47.2%), N1 in 42(23.3%), N2 in 31(17.2%), and N3 in 22(12,2%). The detection rate of early gastric cancer using two-phase spiral CT was 100.0%(10 of 10 cases) among elevated lesions and 78.3%(47 of 60 cases) among flat or depressed lesions. With regard to T-stage, there was good correlation between CT image and pathology in 86 of 180 cases(47.8%). Overstaging occurred in 23.3%(42 of 180 cases) and understaging in 28.9%(52 of 180 cases). With regard to N-stage, good correlation between CT image and pathology was noted in 94 of 180 cases(52.2%). The rate of understaging(31.7%, 57 of 180 cases) was higher than that of overstaging(16.1%, 29 of 180 cases)(p<0.001). The detection rate of early gastric cancer using two-phase spiral CT was 81.4%, and there was no significant difference in detectability between elevated and depressed lesions. Two-phase spiral CT for determing the T-and N-stage of gastric cancer was not effective;it was accurate in abont 50% of cases understaging tended to occur.=20

  8. Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Meurer, A.; Schwitalle, M.; Engelhardt, O.; Heine, J. [Johannes Gutenberg-Univ. Mainz (Germany). Orthopaedische Klinik und Poliklinik; Kreitner, K.F. [Johannes Gutenberg-Univ. Mainz (Germany). Inst. fuer Klinische Strahlenkunde

    1998-09-18

    The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

  9. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  10. Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Breitenseher, M.J. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Huber, M. [Pathologisch-Bakteriologisches Inst. Baumgartner Hoehe, Wien (Austria); Zettl, R. [Orthopaedisches Krankenhaus Gersthof, Wien (Austria); Rottmann, B. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria); Haller, J. [Hanuschkrankenhaus, Wien (Austria). Radiologische Abt.; Imhof, H. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Klinische Einrichtung Magnet Resonanz und Abt. fuer Osteoradiologie]|[Ludwig Boltzmann Inst. fuer Radiologische Tumordiagnostik, Wien (Austria)

    1997-04-01

    Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep calcified cartilage layer was measured. Results: Measurements without the transition zone showed a mean underestimation of talus cartilage thickness of 46.8% (41.3-52.1) for T{sub 1}-SE and 47.5% (43.1-52.1) for fat saturated FLASH-3D images. Considering the transition zone the mean values were 25.0% (23.1-26.2) and 14.1% (6.7-21.5). The histologic specimens showed a three-fold increase of thickness of deep calcified cartilage layer. Conclusions: Measurements of the cartilage layer of the ankle joint on MR images are only accurate if the transition zone (calcified cartilage layer) is considered and the optimal pulse sequence (FLASH-3D-fat-sat) is applied. (orig.) [Deutsch] Ziel: Die Frage, ob die MRT die Dicke des Knorpels exakt bestimmen kann, wird kontrovers diskutiert. Ziel der Studie war die Bestimmung der Knorpeldicke am oberen Sprunggelenk mit der MRT im Vergleich zum anatomischen Praeparat. Material und Methode: Sprunggelenke von 4 Leichen wurden auf einem 1,5 Tesla MR-Geraet mittels T{sub 1}-betonter Spin

  11. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  12. Applications of cerebral MRI in neonatology; MRT bei Neugeborenen mit Verdacht auf zerebrale Stoerung

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, D. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Neuroradiologie; Kuhle, S. [Universitaetsklinik fuer Kinder- und Jugendheilkunde, Wien (Austria). Abt. fuer Neonatologie, angeborene Stoerungen und Intensivmedizin; Blaicher, W. [Abt. fuer Frauenheilkunde und Praenatale Diagnostik, Wien (Germany)

    2000-01-01

    Magnetic resonance tomography (MRT) has become the most important method in the workup of infantile cerebral complications after primary sonography. Cerebral MR examination and image interpretation during the infantile period require extensive knowledge of morphological manifestations, their pathophysiological background, and frequency. The choice of imaging parameters and image interpretation is demonstrated in infarctions and hemorrhages of the mature and immature brain. A review of the main differential diagnoses is also given. The relevance of MR spectroscopy and fetal MRI is discussed. (orig.) [German] Zur Abklaerung zerebraler Veraenderungen bei Neugeborenen hat sich die Magnetresonanztomographie (MRT) als wichtigste weiterfuehrende Methode nach der Sonographie entwickelt. Die Durchfuehrung und Auswertung der MR-Untersuchungen erfordern jedoch eine genaue Kenntnis der morphologischen Manifestation, des pathophysiologischen Hintergrunds und der Haeufigkeit bestimmter zerebraler Komplikationen in diesem Lebensalter. Resuemee: Ausgehend von zerebrovaskulaeren Erkrankungen werden diese Fragen behandelt, wobei sowohl auf die Auswahl der adaequaten Untersuchungsparameter als auch auf die Bildinterpretation und die wichtigsten Differentialdiagnosen eingegangen wird. Die Bedeutung von MR-Spektroskopie und fetaler MRT wird diskutiert. (orig.)

  13. MR imaging in gynecology and obstetrics; MR-Tomographie in Gynaekologie und Geburtshilfe

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, M.; Tontsch, P.; Schulz-Wendtland, R. (eds.)

    2000-07-01

    The toolbook covers the full range of indications for MRI in obstetrics and gynecology. It is the joint work of radiologists and obstetrician-gynecologists and supplies state-of-the-art information needed by doctors in the private practice or a hospital department. Examples from the Table of Contents: Physical principles of MRI, applications and performance aspects. Systematic presentation of diagnostic findings for comparative analysis and assessment. Biological effects and risks. Benign and malignant neoplasms of the mammary glands and the female genital organs. MRI for prenatal care and diagnostic evaluation. New method: MR spectroscopy. (orig./CB) [German] Das Lehrbuch deckt alle Indikationen der MRT in Gynaekologie und Geburtshilfe ab. Es wurde von Radiologen und Frauenaerzten gemeinsam verfasst und ist daher praxisgerecht. Aus dem Inhalt: Physikalische Grundlagen und Durchfuehrung der MRT und Systematik fuer die Beurteilung der MRT-Befunde. Biologische Wirkungen und Risiken, benigne und maligne Erkrankungen der Brustdruese und der weiblichen Genitalorgane. MRT in der Schwangerschaft. Neue Methode: MR-Spektroskopie. (orig./AJ)

  14. Magnetic resonance tomography (MRT) in bronchial carcinoma

    International Nuclear Information System (INIS)

    Felix, R.; Bittner, R.; Schoerner, W.; Weiss, T.

    1988-01-01

    Comparative studies were made of 47 patients suffering from histologically and cytologically confirmed bronchial carcinoma, using CT and MRT respectively. CT examinations were performed before and after intravenous administration of contrast medium, whereas the MR examinations were conducted via EEG-triggered T 1 and T 2 marked SE sequences in the axial and coronary planes. Both methods were assessed in respect of tumour visualisation and documentation of tumour spread. Staging of tumour and lymph nodes yielded largely concurring results for CT and MRT. Exceptions were seen in 7 of 10 patients with malignant involvement of the pericardium and in 3 of 27 patients with lymph node metastases located mediastinally and subcarinally where only MRT showed a positive involvement of the pericardium or lymph nodes (with possible consequences for the staging of the tumour or lymph nodes). Decisive advantages of MRT compared with CT were seen in the identification of infiltration of the aortic-wall, in the differentiation of the poststenotic syndrome, in the visualisation of the thoracic wall infiltration and functional information on blood flow rate in upper venolus obstruction caused by a carcinoma. (orig.) [de

  15. Epiphyseal injuries of the distal tibia. Does MRI provide useful additional information?; Epiphysenfugenverletzungen der distalen Tibia. Sinnvolle Mehrinformation durch die MRT?

    Energy Technology Data Exchange (ETDEWEB)

    Iwinska-Zelder, J.; Schmidt, S.; Ishaque, N.; Klose, K.J.; Hoppe, M. [Marburg Univ. (Germany). Abt. fuer Strahlendiagnostik; Schmitt, J.; Gotzen, L. [Marburg Univ. (Germany). Medizinisches Zentrum fuer Operative Medizin

    1999-01-01

    Plain film radiography often underestimates the extent of injury in children with epiphyseal fracture. Especially Salter-Harris V fractures (crush fracture of the epiphyseal plate) are often primarily not detected. MRI of the ankle was performed in 10 children aged 9-17 (mean 14) years with suspected epiphyseal injury using 1.0-T Magnetom Expert. The fractures were classified according to the Salter-Harris-Rang-Odgen classification and compared with the results of plain radiography. In one case MRI could exclude epiphyseal injury; in four cases the MRI findings changed the therapeutic management. The visualisation of the fracture in three orthogonal planes and the possibility of detection of cartilage and ligamentous injury in MR imaging makes this method superior to conventional radiography and CT. With respect to radiation exposure MRI instead of CT should be used for the diagnosis of epiphyseal injuries in children. (orig.) [Deutsch] Die konventionelle Roentgendiagnostik unterschaetzt haeufig das Ausmass der kindlichen Extremitaetenfrakturen mit Epiphysenbeteiligung (Typ Salter-Harris). Insbesondere werden die Kompressionsfrakturen der Wachstumsfuge (Salter-Harris V) primaer haeufig nicht erkannt. Prospektiv wurden 10 Kinder im Alter von 9-17 Jahren (Durchschnittsalter = 14 J.) mit Verdacht auf eine epiphysaere Fraktur der distalen Tibia magnetresonanztomographisch (1.0-Tesla Magnetom Expert), untersucht. Die MRT-Ergebnisse wurden auf der Basis der Klassifikation nach Salter-Harris-Rang-Odgen mit den konventionellen Roentgenbildern verglichen. In einem Fall, bei einem 15jaehrigen Patienten, gelang durch die MRT der Ausschluss einer epiphysaeren Verletzung. In 7 Faellen fuehrte der MRT-Einsatz zu einer Aenderung der Klassifikation nach Salter-Harris. Hieraus resultierte bei 4 Patienten ein Therapiewechsel. Da Frakturen, die sie begleitenden Knorpellaesionen und ligamentaere Verletzungen multiplanar dargestellt werden koennen, weist die MRT deutliche Vorteile

  16. Spiral CT findings of inflammatory pseudotumor of the liver

    International Nuclear Information System (INIS)

    Lee, Ha Jong; Nam, Kyung Jin; Lee, Ki Nam; Park, Byeong Ho; Choi, Jong Cheol; Koo, Bong Sik; Nam, Ki Dong; Kim, Chan Seong

    1998-01-01

    To assess the spiral CT findings of inflammatory pseudotumor of the liver(IPTL), in order to distinguish this tumor from hepatocellular carcinoma, hepatic abscess or other space occupying liver lesions. The spiral CT findings of IPTL were retrospectively evaluated in six patients. All cases were confirmed by ultrasonography-guided gun biopsy. Four patients were men and two were women, and they were aged between 37 and 74 (mean, 49) years. The site, size, and number of IPTL were assessed, and their enhancement patterns were evaluated during the arterial, portal and delayed phases of spiral CT. Five cases involved a solitary mass and in one there were multiple masses with surrounding small nodules. Four cases occurred in the right lobe and two in the left lobe. Four of five surrounding nodules were in the left lobe. During the arterial phase of spiral CT scanning, three layers were separated from four of five cases of solitary mass;they were composed of central and peripheral portions of low attenuation, and an intermediate portion of isoattenuation. Delayed enhancement of the peripheral portion was prominent during the delayed phase. In the case involving multiple masses three layers were not seen during the arterial phase, but during the delayed phase enhancement was noted. The features of three layers, as seen on spiral CT, is considered to be very specific for distinguishing IPTL from other hepatic focal lesions.=20

  17. Malignant focal hepatic lesions complicating underlying liver disease: dual-phase contrast-enhanced spiral CT sensitivity and specificity in orthotopic liver transplant patients

    International Nuclear Information System (INIS)

    Mortele, K.J.; De Keukeleire, K.; Praet, M.; Van Vlierberghe, H.; Hemptinne, B. de; Ros, P.R.

    2001-01-01

    The aim of this study was to determine the accuracy of contrast-enhanced biphasic spiral CT as a screening tool in the preoperative evaluation of orthotopic liver transplant (OLT) patients. Spiral-CT examinations were performed before liver transplantation in 53 patients. Scans were retrospectively reviewed and compared with pathologic findings in fresh-sectioned livers. When findings between spiral CT and pathology were discordant, formalized livers were reexamined with lesion-by lesion evaluation. Fresh pathologic evaluation revealed 23 liver lesions (16 HCC, 7 macro-regenerative nodules). Malignancy was identified in 13 of 53 patients (24.5%). Pre-transplantation spiral CT depicted 27 liver lesions (23 HCC, 4 macro-regenerative nodules). Malignancy was suspected in 14 patients (26.4%). In 10 of 53 (18.9%), spiral CT and pathologic evaluation were discordant. Subsequent retrospective pathologic evaluation showed malignancy in 4 additional patients. Spiral CT compared with the retrospective pathologic findings revealed 36 real-negative, 14 real-positive, 0 false-positive, and 3 false-negative patients with malignancy. Sensitivity and specificity of spiral CT in detection of malignancy was 82 and 100%, respectively. Contrast-enhanced biphasic spiral CT is an accurate technique in the evaluation of patients preceding OLT. Routine fresh-sectioned liver pathologic findings are not as sensitive as previously estimated. (orig.)

  18. Prevalence of ligamentum arteriosum calcification on multi-section spiral CT and digital radiography.

    Science.gov (United States)

    Hong, Gil-Sun; Goo, Hyun Woo; Song, Jae-Woo

    2012-06-01

    To investigate the prevalence of ligamentum arteriosum calcification (LAC) on multi-section spiral CT and digital radiography. Five hundred and eight children and 232 adults who performed multi-section chest CT were included in this study and were divided into nine age groups: A (0-5 years), B (6-10 years), C (11-15 years), D (16-20 years), E (21-30 years), F (31-40 years), G (41-50 years), H (51-60 years), and I (61-70 years). Two radiologists assessed the presence of LAC on axial and coronal CT images, defined as focal calcific density on both or on one plane with attenuation >100 Hounsfield unit. The prevalence of LAC on CT was compared between children and adults, and between unenhanced and enhanced CT in children. The prevalence of LAC on digital radiography was evaluated in 476 children. The prevalence of definite LAC on unenhanced multi-section CT was significantly higher in children (37.8 %) than in adults (11.2 %) (P CT were 4.5, 12.8, 8.1, 19.0, 0.0, 0.0, 0.0, 2.0, and 1.9 %. In children, the prevalence of LAC was significantly higher on unenhanced than on enhanced CT (37.8 vs. 16.4 %, P children. LAC is frequently observed in children and adults on multi-section spiral CT, more frequently than previously reported. Compared with that on multi-section spiral CT, the prevalence of LAC on digital radiography is substantially low.

  19. Diffusion-weighted MRI of the prostate; Diffusionsgewichtete MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, U.G.; Scherr, M.K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Mueller-Lisse, U.L. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Klinik und Poliklinik fuer Urologie, Muenchen (Germany); Zamecnik, P.; Schlemmer, H.P.W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung fuer Radiologische Diagnostik, Heidelberg (Germany)

    2011-03-15

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [German] Die diffusionsgewichtete MRT (''diffusion-weighted imaging'', DWI) kann die MRT der Prostata bei der Erkennung und Lokalisation von Prostatakarzinomen besonders nach vorangehender, negativer Stanzbiopsie ergaenzen. In 13 klinischen Original- und 2 Uebersichtsarbeiten des Jahres 2010 zeigt sich, dass die DWI Prostatakarzinome an Einschraenkungen der freien Teilchenbeweglichkeit bei erhoehter Zelldichte qualitativ im Bild oder quantitativ an Hand des ''apparent diffusion coefficient'' (ADC) nachweist. Den ADC in der Prostata beeinflussen Staerke der Diffusionsgewichtung, Lokalisation (periphere Zone, Transitionalzone), Vorliegen von Prostatitis oder Einblutung sowie Streudichte und Differenzierung von Prostatakarzinomzellen. Unterschiede zwischen gesundem

  20. Three-dimensional spiral CT for neurosurgical planning.

    Science.gov (United States)

    Klein, H M; Bertalanffy, H; Mayfrank, L; Thron, A; Günther, R W; Gilsbach, J M

    1994-08-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important.

  1. Three-dimensional spiral CT for neurosurgical planning

    International Nuclear Information System (INIS)

    Klein, H.M.; Bertalanffy, H.; Mayfrank, L.; Thron, A.; Guenther, R.W.; Gilsbach, J.M.

    1994-01-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important. (orig.)

  2. Value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Wang Kang; Zhao Zehua; Wang Zhi; Wang Weizhong; Xu Songsen; Zhang Miao; Liu Wenjin; Zhang Guozhen; Feng Dianxu

    2005-01-01

    Objective: To investigate the value of multi-slice spiral CT MPVR reconstruction in the diagnosis of acute appendicitis. Methods: A total of 39 patients with clinically suspected acute appendicitis underwent surgery from February, 2002 to September, 2003. They were prospectively examined before surgery with routine CT scanning and MPVR reconstruction spiral CT. 31 cases of appendicitis were confirmed after appendectomy. CT scans and surgery-pathology reports were evaluated on a five-grade scale from hyperemic-edematous appendix to abscess (normal appendix: 0 grade). Results: The results of spiral CT MPVR reconstruction were compared with the surgical and pathologic findings at appendectomy, yielding an accuracy of 87.2%, sensitivity of 90.3%, specificity of 75%, positive predictive value of 93.3%, and negative predictive value of 66.7%, respectively. Results of routine CT yielded an accuracy of 38.5%, sensitivity of 38.7%, specificity of 37.5%, positive predictive value of 70.6%, and negative predictive value of 13.6%, respectively. MPVR reconstruction signs of 28 patients with acute appendicitis included enlarged appendix ( > 6 mm) (96.4%), appendicoliths (26.7%), caecal apical thickening (36.7%), periappendiceal inflammation (71.4%), and abscess (10.7%). Conclusion: The use of spiral CT MPVR reconstruction in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to a significant improvement in the preoperative diagnosis and maybe a decrease in surgical-pathologic severity of appendiceal disease. (authors)

  3. Craniocerebral trauma. Magnetic resonance imaging of diffuse axonal injury; Schaedel-Hirn-Trauma. MRT bei diffuser axonaler Verletzung

    Energy Technology Data Exchange (ETDEWEB)

    Mallouhi, A. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Abteilung fuer Neuro- und Muskuloskelettale Radiologie, Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2014-09-15

    fuer Behinderung oder Tod. Es fuehrt haeufig zu einer axonalen Scherverletzung. Die daraus resultierende Pathologie wird als diffuse axonale Verletzung (''diffuse axonal injury'', DAI) bezeichnet. Die DAI-assoziierten Laesionen treten bilateral und verteilt auf und werden in der oberflaechlichen und in der tiefen weissen Substanz beobachtet. Sie finden sich sowohl in der Naehe als auch weit entfernt von der Aufprallstelle. Bei klinischem Verdacht auf eine diffuse axonale Verletzung ist die Magnetresonanztomographie (MRT) zur weiteren Abklaerung die Methode der Wahl, dies insbesondere bei Patienten mit einer unauffaelligen Computertomographie des Schaedels. Zur Abklaerung des Gehirns nach einem Schaedel-Hirn-Trauma (SHT) wird ein multimodales MR-Verfahren angewendet, das in 2 Kategorien unterteilt werden kann: strukturelle und funktionelle MR-Bildgebung. Fuer die strukturelle MRT kommen hauptsaechlich die Fluid-attenuated-inversion-recovery(FLAIR)-Gewichtung und die suszeptibilitaetsgewichtete Bildgebung (SWI) zum Einsatz. Die SWI ist ausserordentlich auf Blutabbauprodukte empfindlich, welche als kleine Signalausloeschungen an 3 typischen Lokalisationen (an der Rinden-Mark-Grenzzone, im Corpus callosum und im Hirnstamm) zur Darstellung kommen. Die funktionelle MRT umfasst eine Gruppe staendig in Entwicklung befindlicher Techniken, welche ein grosses Potenzial zur optimalen Evaluierung der weissen Substanz bei Patienten nach einem SHT haben. Diese modernen bildgebenden Verfahren ermoeglichen die Visualisierung der mit Scherverletzungen assoziierten Veraenderungen, wie die Funktionsbeeintraechtigung der Axone, die verminderte Durchblutung und abnormale metabolische Aktivitaet der betroffenen Gehirnanteile. Die multimodale MR-Abklaerung bei Patienten mit DAI fuehrt zu einer detaillierteren und differenzierteren Darstellung der zugrunde liegenden pathophysiologischen Veraenderungen der verletzten Nervenbahnen und traegt zur Verbesserung der

  4. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  5. Value of magnetic resonance imaging in diffuse liver diseases; Stellenwert der MRT bei diffusen Lebererkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, N.; D' Anastasi, M.; Reiser, M.F.; Zech, C.J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2012-08-15

    Diffuse liver diseases show an increasing prevalence. The diagnostic gold standard of liver biopsy has several disadvantages. There is a clinical demand for non-invasive imaging-based techniques to qualitatively and quantitatively evaluate the entire liver. Ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) are routinely used. Steatosis: chemical shift and frequency selective imaging, MR spectroscopy (MRS). Hemochromatosis: MR-based iron quantification. Fibrosis: MR elastography, diffusion, intravoxel incoherent motion (IVIM) and MR perfusion. T1-weighted in and opposed phase imaging is the clinically most frequently used MR technique to noninvasively detect and quantify steatosis. New methods for quantification that are not influenced by confounders like iron overload are under investigation. The most sensitive method to measure the fat content of the liver is MRS. As data acquisition and analysis remain complex and there is no whole organ coverage, MRS of the liver is not a routine method. With an optimized protocol incorporating T2* sequences, MRI is the modality of choice to quantify iron overload in hemochromatosis. Standard MR sequences cannot depict early stages of liver fibrosis. Advanced MR techniques (e.g. elastography, diffusion, IVIM and perfusion) for noninvasive assessment of liver fibrosis appear promising but their role has to be further investigated. (orig.) [German] Die Praevalenz diffuser Lebererkrankungen nimmt zu. Der klinische Goldstandard, die Leberbiopsie, hat zahlreiche Nachteile. Es besteht ein Bedarf an bildgebenden Verfahren zur nichtinvasiven qualitativen und quantitativen Beurteilung der gesamten Leber bei diesen Erkrankungen. Hier sind Ultraschall, CT und MRT zu nennen. Steatosis: Chemical-shift- und frequenzselektive Bildgebung, MR-Spektroskopie (MRS) zur Fettquantifizierung. Haemochromatose: MR-basierte Eisenquantifizierung. Fibrose: MR-Elastographie, Diffusion, ''intravoxel incoherent motion

  6. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  7. MRI of the fetal abdomen; MRT des fetalen Abdomens

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, M.; Brugger, P.C.; Witzani, L.; Prayer, D. [Medizinische Universitaet Wien (Austria). Universitaetsklinik fuer Radiodiagnostik

    2006-02-15

    Magnetic resonance imaging (MRI) is an important diagnostic component for central nervous system and thoracic diseases during fetal development. Although ultrasound remains the method of choice for observing the fetus during pregnancy, fetal MRI is being increasingly used as an additional technique for the accurate diagnosis of abdominal diseases. Recent publications confirm the value of MRI in the diagnosis of fetal gastrointestinal tract and urogenital system diseases. The following report provides an overview of MRI-examination techniques for the most frequent diseases of the abdomen. (orig.) [German] Die MRT ist ein wichtiger Bestandteil zur Diagnostik des zentralen Nervensystems und thorakaler Erkrankungen in der fetalen Entwicklung. Wenngleich der Ultraschall die Methode der Wahl zur Ueberwachung des Feten in der Schwangerschaft bleibt, bekommt die fetale MRT als zusaetzliche Untersuchungstechnik zur akkuraten Diagnostik abdomineller Erkrankungen immer groessere Bedeutung. Die neueren Publikationen bestaetigen v. a. den Stellenwert der MRT in der Diagnose von Erkrankungen des fetalen Gastrointestinaltrakts und des Urogenitalsystems. Im Folgenden soll ein Ueberblick ueber die MR-Untersuchungstechnik der haeufigsten Erkrankungen des Abdomens gegeben werden. (orig.)

  8. CT and MRI in progressive multifocal leukoencephalopathy. CT und MRT der progressiven multifokalen Leukenzephalopathie (PML)

    Energy Technology Data Exchange (ETDEWEB)

    Lanfermann, H. (Inst. und Poliklinik fuer Radiologische Diagnostik, Koeln Univ. (Germany)); Heindel, W. (Inst. und Poliklinik fuer Radiologische Diagnostik, Koeln Univ. (Germany)); Schroeder, R. (Neuropathologie des Inst. fuer Pathologie, Koeln Univ. (Germany)); Lackner, K. (Inst. und Poliklinik fuer Radiologische Diagnostik, Koeln Univ. (Germany))

    1994-07-01

    Radiological findings and course of progressive multifocal leukoencephalopathy in 14 patients (1 woman, 13 men; 13 HIV seropositive, 1 chronic lymphatic leukaemia) were analysed retrospectively and correlated with clinical symptoms. A total of 21 CT and 16 MRI studies were evaluated. CT scans and MR images of 9 patients, which had been obtained in less than two weeks, could be compared to each other. MRI was superior to CT: 6 lesions with a diameter of 1 cm and below were not detected on CT scans, in 5 patients the extent of lesions was underestimated. Cortical involvement, mass effect or signs of atrophy were missing. Only 1 of 65 lesions showed a tiny enhancement after Gd injection. Due to the pattern and spread of lesions, which showed a close correlation to the neurologic symptoms, three different types of PML are suggested: 1. Initial precentral demyelinisation with contralateral hemiparesis (n=8); 2. lesions in temporo-occipital locations with visual disturbances (n=2); 3. predominantly bilateral lesions of cerebellar white matter with ataxia (n=4). (orig.)

  9. Hepatic hemangioma: contrast enhancement patterns on two-phase spiral CT

    International Nuclear Information System (INIS)

    Yun, Eun Joo; Choi, Byung Ihn; Han, Joon Koo; Jang, Hyun Jung; Kim, Tae Kyoung; Kim, Ah Young; Lee, Ki Yeol

    1998-01-01

    To evaluate contrast enhancement patterns of hemangioma according to size, as seen during the arterial and portal venous phase of spiral CT. Overall, the most common enhancement pattern was peripheral high (44/82, 53.7%), during the arterial and portal venous phase. The second and third most common patterns were uniform high (11/82, 13.4%) and peripheral high-uniform high (9/82, 11.0%), also during the arterial and portal venous phase. In tumors smaller than 20 mm, low-low attenuation was seen in eight (9.8%), and iso-low attenuation in two (2.4%), during the arterial and portal venous phase, respectively. On two-phase spiral CT, the most common enhancement pattern of hemangioma was peripheral high, seen during the arterial and portal venous phase. However, a small hemangioma less than 2cm may show atypical patterns, including low and iso attenuation. (author). 23 refs., 1 tab., 4 figs

  10. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  11. Imaging and therapy of a chondroblastoma; Bildgebung und Therapie eines Chondroblastoms

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, J.; Meyer, D.R.; Geufke, P.; Andresen, R. [Krankenhaus Guestrow, Akademisches Lehrkrankenhaus der Universitaet Rostock (Germany)

    2002-07-01

    ] Das Chondroblastom ist eine seltene lytische ossaere Laesion, welche typischerweise in den Epiphysen der langen Roehrenknochen zu finden ist. Wir praesentieren die differentialdiagnostische Bildgebung und die opterative Therapie kasuistisch an einem Chondroblastom der proximalen Tibiaepiphyse. In der traumatologischen Ambulanz stellte sich ein 16 jaehriger Patient mit unklarem, seit Monaten zunehmenden Kniegelenksschmerz vor. Ein akutes Trauma war nicht erinnerlich. Zur weiteren Abklaerung erfolgte eine konventionelle Roentgenaufnahme in zwei Ebenen, ein Duennschicht CT, ein multiplanares MRT vor und nach Gd-DTPA und eine 3-Phasen-Skelettszintigrafie. Die konventionelle Roentgendiagnostik zeigt eine glattbegrenzte, osteolytische, exzentrische Laesion mit Randsklerosierung, welche die Epiphysenfuge der proximalen Tibia nicht ueberschreitet. In der Duennschicht-CT findet sich eine exzentrische Osteolyse mit typischen, schmalen Sklerosierungssaum und zentralen Verkalkungen. In der hochaufloesenden MRT zeigen die T2 gewichteten Sequenzen eine lokal begrenzte, epiphysaere, lobulierte Laesion mit einem heterogenen z.T. angehobenen Signal, eine weitere Signalanhebung zeigt sich in den T1 gewichteten Sequenzen nach Gabe von Gd-DTPA. Perifokal findet sich ein epiphysaeres Oedem und diskrete Fluessigkeit im Kniebinnenraum. In der Skelettszintigrafie kommt es zu einer starken fokalen und diffusen Mehrbelegung der proximalen, lateralen Tibiaepiphyse. Nach Diagnosestellung wurde eine Kuerettage des Defektes durchgefuehrt und anschliessend nach histologischer Bestaetigung der Diagnose die komplettierende Kuerettage und Spongiosaplastik vorgenommen. Unter Beruecksichtigung der Tumorlokalisation und des Alters des Patienten laesst sich bereits mit der konventionellen Bildgebung eine praktisch sichere Diagnose stellen. Eine ergaenzende MRT oder CT kann zur endgueltigen Abklaerung hilfreich sein, eine 3-Phasen-Skelettszintigrafie ist ueberfluessig. Die Therapie der Wahl ist die

  12. Floating venous thrombi: diagnosis with spiral-CT-venography

    International Nuclear Information System (INIS)

    Gartenschlaeger, M.; Schmidt, J.A.

    1996-01-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [de

  13. In-vitro studies to determine the degree of stenosis using spiral-CT angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Lenk, G.; Jenett, M.; Elsner, H.; Kaiser, W.A.; Kellner, M.; Schultz, G.; Trusen, A.; Hahn, D.

    1998-01-01

    Purpose: Aim of the study was to evaluate the influence of different spiral-CT parameters for the visualisation of vascular stenoses, especially of the renal arteries. Material and methods: Models with a density equivalent to that of fat, filled with diluted contrast agent, and an inner lumen of 4, 6, 8 mm were scanned in x-, y- and z-direction. Data were acquired in up to 24 second long spiral-CT scans using different spiral-CT parameters (collimation, table speed, reconstruction algorithm, tube current). Detection of the degree of stenosis was achieved by assessment of the axial images and 3D reconstructions. Results: The best correlation between real and measured degree of stenosis was seen by using a small collimation, a low table increment and assessment of the axial images reconstructed in standard algorithm. The stenosis degrees of models directed in x- and y-direction were overestimated and those in z-direction were underestimated depending on the spiral-CT parameters. Conclusion: For optimal imaging of renal artery stenoses, collimation of 2 mm (pitch=1-2) and a reconstruction interval of 1 mm is recommended. (orig.) [de

  14. Pre- and post-operative evaluation of ventricular function, muscle mass and valve morphology by MR tomography in Ebstein's anomaly; Prae- und postoperative Beurteilung der ventrikulaeren Funktion, Muskelmasse und Klappenmorphologie bei der Ebstein-Anomalie mit der Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, M.; Oellinger, H.; Amthauer, H.; Hoffmann, T.; Felix, R. [Charite-Campus Virchow, Berlin (Germany). Klinik fuer Strahlenheilkunde; Ewert, P.; Nagdyman, N.; Lange, P. [Deutsches Herzzentrum Berlin (Germany). Abt. fuer Angeborene Herzfehler/Kinderkardiologie; Hetzer, R. [Deutsches Herzzentrum Berlin (Germany). Abt. fuer Herz-, Thorax- und Gefaesschirurgie

    2000-05-01

    Purpose: To evaluate the value of MRT with spin echo (SE) and CINE gradient echo (GE) sequences for the pre- and postoperative assessment of patients with Ebstein's anomaly. Methods: Twelve patients within the ages of four to 49 years (mean 22{+-}12 years) were examined pre- (n=5) or postoperatively (n=7) after tricuspid valve reconstruction with a 1.5 T scanner. For the anatomical assessment, an ECG-gated transverse SE-sequence, for the assessment of valve morphology and function as well as for volumetry a CINE GE-sequence with retrospective gating was used. With the use of the multislice-multiphase technique, after summing up the manually outlined epi- and endocardial areas, endsystolic (ESV) and enddiastolic volumes (EDV), ejection fraction (EF), stroke volume (SV), and muscle mass (MM) were calculated for both ventricles. Results: The differentiation of the displaced parts of the tricuspid valve (TV) was insufficient with static SE, but was possible in all patients with CINE-MRT. Like in Doppler echocardiography, a qualitative assessment of tricuspid insufficiency was possible in CINE-MRT, the mean incompetence grade preoperative was 1.8 ({+-}0.8), postoperative 0.7 ({+-}0.5). The mean RV-EF in the preoperative group was 41.8% ({+-}6.4), in the postoperative group 47.9% ({+-}10.6), the mean LV-EF preoperative 47.4% ({+-}8.5%), postoperative 63,0% ({+-}9.4). Conclusion: CINE-MRT should rather be used than SE for the assessment of valve morphology. EF, muscle mass and tricuspid incompetence can also be calculated pre- and postoperative with CINE-MRT. (orig.) [German] Zielsetzung: Zu ermitteln, welchen Beitrag die MRT mit der Spin-Echo-(SE) bzw. CINE-Gradienten-Echo-Sequenz (GE) zur prae- und postoperativen Beurteilung bei Patienten mit Ebstein-Anomalie leisten kann. Material und Methode: Es wurden 12 Patienten im Alter zwischen 4 und 49 Jahren (im Mittel 22{+-}12 Jahre) prae- (n=5) oder postoperativ (n=7) nach einer Trikuspidalklappenkonstruktion an einem 1

  15. Sports-related injuries of the spine; Sportverletzungen und -schaeden der Wirbelsaeule

    Energy Technology Data Exchange (ETDEWEB)

    Hochmuth, K. [Orthopaedische Universitaetsklinik, Stiftung Friedrichsheim der Johann-Wolfgang-Goethe-Universitaet Frankfurt am Main (Germany); Institut fuer Diagnostische und Interventionelle Radiologie der Johann-Wolfgang-Goethe-Universitaet Frankfurt am Main (Germany); Mack, M.G.; Vogl, T.J. [Institut fuer Diagnostische und Interventionelle Radiologie der Johann-Wolfgang-Goethe-Universitaet Frankfurt am Main (Germany); Kurth, A.A.; Zichner, L. [Orthopaedische Universitaetsklinik, Stiftung Friedrichsheim der Johann-Wolfgang-Goethe-Universitaet Frankfurt am Main (Germany)

    2002-10-01

    Different sports show different patterns and frequencies of injuries, which are discussed in this paper. About 3% of all sports accidents relate to the spine. These injuries often have far-reaching consequences for the patients. A very early and extensive diagnosis of all changes is decisive for the start of an adequate therapy and thus for the prognosis of the injury. Radiological diagnosis is also of decisive importance for the documentation of late injuries and in the question of rehabilitation. Here special focus is put on MRT and CT diagnostics.A healthy spine of humans is normally able to resist all static and dynamic strains of the usual sports. However, anomalies and dysfunctions of the spine can reduce its capacity to resist strain. The recommendations of sporting activities are given according to the extent of deflection and the expected growth. The importance of radiology in primary diagnosis and in the follow-up due to typical changes like scoliosis, Morbus Scheuerman, spondylolysis and spondylolisthesis is discussed here as well. (orig.) [German] Die verschiedenen Sportarten weisen unterschiedliche Verletzungshaeufigkeiten und -muster auf, die im Rahmen dieser Uebersichtsarbeit diskutiert werden sollen. Circa 3% der Sportunfaelle betreffen die Wirbelsaeule. Diese Verletzungen sind haeufig von besonderer Tragweite fuer den Patienten. Eine fruehestmoegliche und umfassende Diagnose aller Veraenderungen ist dabei entscheidend fuer die Einleitung einer adaequaten Therapie und somit fuer die Prognose der Verletzung. Auch in der Dokumentation von Spaetschaeden und in der Frage der Rehabilitation kommt der radiologischen Diagnostik eine entscheidende Bedeutung zu. Ein besonderer Fokus wird dabei auf die Magnetresonanztomographie-(MRT-)und Computertomographie-(CT-)Diagnostik gelegt.Die gesunde Wirbelsaeule des Menschen ist in der Regel allen statischen und dynamischen Belastungen der ueblichen Sportarten gewachsen. Formanomalien und Funktionsstoerungen der

  16. 3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, W; Bauerfeind, P; Pelkonen, P; Steiner, P; Krestin, G P; Debatin, J F [MRI-Zentrum, Dept. Diagnostische Radiologie, Universitaetsspital, Zurich (Switzerland)

    1997-09-01

    Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies were missed. VC presented the morphology of colon haustra as well as of all endoluminally growing lesions in a manner similar to endoscopy. The colon masses showed uptake of contrast media and could thus be differentiated from air or faeces. (orig./AJ) [Deutsch] Ziel: Externe und endoskopische Identifizierung kolorektaler Pathologien mittels MRT. Material und Methoden: 5 Patienten (36-88 Jahre), zwei mit Normalbefund, drei mit verschiedenen kolorektalen pathologischen Befunden (Divertikulose, Polypen, Karzinom), wurden nach der Kolonoskopie mit der MRT untersucht. Dazu wurde das Kolon unter MR-Sichtkontrolle mit einer Gadolinium-Wasser-Mischung gefuellt und als 3D-Datensatz atemangehalten in Bauch- und Rueckenlage aufgenommen. Anschliessend wurden multiplanare, T{sub 1}-gewichtete 2D-Sequenzen vor und nach i.v. Gd-DTPA-Gabe akquiriert. Die 3D-Datensaetze wurden interaktiv unter Zuhilfenahme verschiedener Darstellungsformen analysiert: Maximale Intensitaetsprojektion (MIP), Oberflaechendarstellung

  17. Hypoxic-ischemic encephalopathy in neonates and infants: an evaluation with spiral CT

    International Nuclear Information System (INIS)

    Zhu Linghua

    2006-01-01

    Objective: To evaluate spiral CT imaging in the diagnosis of hypoxic-ischemic encephalopathy (HIE) in the neonates and infants. Methods: 112 children with history of asphyxia in peri-natal period and evident clinical symptoms were evaluated with Spiral CT. CT findings were studied. Results: 46 minor cases, 57 moderate cases and 9 severe cases were found out of 112 patients. Intracranial hemorrhage was revealed in 38 cases. Mortality occurred in 1 case. Conclusion: Spiral CT is helpful for evaluating brain damage and predicting prognosis in neonates with HIE. (authors)

  18. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  19. Functional MRT in psychiatry and neurology. 2. rev. and upd. ed.; Funktionelle MRT in Psychiatrie und Neurologie

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Frank [Universitaetsklinikum Aachen (Germany); Fink, Gereon R. (eds.) [Forschungszentrum Juelich GmbH (Germany); Uniklinik Koeln (Germany)

    2013-08-01

    The book on functional MRT in psychiatry and neurology covers the following topics: (I) Fundamentals: functional neuro-anatomy, fundamentals of NMR imaging, basic research on the clinical use for diagnostics and therapy; basics of morphometry; real-time fMRT, planning and execution of experimental paradigms; data analysis and statistics; reliability and quality of fMRT experiments; eye movement, neuropharmacologic functional imaging, gender dependent effects, age dependent effects, resting state fMRT; meta analyses. (II) Higher brain achievements: movement and action, perception and attention, visual system and object processing, auditory system, executive functions, somatosensoric system, memory, learning and gratification system, functional neuro-anatomy of speech, number processing and calculation, connectivity, social cognition, emotions, olfactory system, functional imaging in the pain research. (III) Disease pattern: dystonia, Parkinson syndrome, Chorea Huntington, aphasia, apraxia, neglect, amnesia, function recovery following apoplexy, schizophrenia, affective disturbances, anxiety and fear, post-traumatic disturbances, hyperactivity syndrome, personality disorder. (IV) Working tools: brain atlas, tool for integrated analyses of structure, functionality and connectivity (SPM anatomy toolbox).

  20. Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint; Technik und Strahlendosis konventioneller Roentgenaufnahmen und Computertomographie des Sakroiliakalgelenks

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, A.G. [Department of Radiology R, Aarhus Kommunehospital (Denmark)

    2004-03-01

    , verursacht jedoch eine relativ hohe Strahlendosis. Aus diesem Grund sollte besonders bei Frauen die CT durch die Verwendung semikoronarer Scanebenen optimiert werden, die mit einer niedrigeren Strahlendosis als bei den axialen Scanebenen auskommen. Eine semikoronare Schnittfuehrung in der CT ruft eine minimale Strahlenbelastung der Ovarien hervor, und die effektive Strahlendosis bei Frauen duerfte deswegen sogar noch niedriger als bei konventionellen AP Roentgenaufnahmen sein. Folglich wird die semikoronare Schnittfuehrung in der CT, bei Verdacht auf Sakroiliitis, diagnostisch und hinsichtlich des Strahlenschutzes bei jungen Frauen als bildgebendes Verfahren bevorzugt, wenn keine Magnetresonanztomographie (MRT) zur Verfuegung steht. Bei Maennern koennen die Gonaden bei konventionellen Roentgenaufnahmen vor der Strahlendosis geschuetzt werden, die CT kann hier lediglich aufgrund des ueberlegenen diagnostischen Wertes als erstes bildgebendes Verfahren gerechtfertigt werden. Die MRT ist aufgrund der fehlenden Risikofaktoren diagnostisch der CT ueberlegen, da zusaetzlich zur Gelenkdestruktion auch Entzuendungszeichen dargestellt werden koennen. Daher ist bei entsprechender Verfuegbarkeit die MRT fuer die Diagnostik der Sakroiliitis zu bevorzugen. (orig.)

  1. MR-Guided vacuum biopsy of 206 contrast-enhancing breast lesions; MRT-gefuehrte Vakuumbiopsie bei 206 Kontrastmittel anreichernden Laesionen der Mamma

    Energy Technology Data Exchange (ETDEWEB)

    Perlet, C.; Schneider, P.; Sittek, H.; Reiser, M.F. [Klinikum der Universitaet Grosshadern, Muenchen (Germany). Inst. fuer Klinische Radiologie; Amaya, B.; Grosse, A.; Heywang-Koebrunner, S.H. [Martin-Luther-Universitaet, Halle (Germany). Klinik fuer Diagnostische Radiologie

    2002-01-01

    Purpose: To determine the accuracy and clinical use of MR-guided vacuum biopsy (VB) of enhancing breast lesions. Material and Methods: 254 lesions were referred to MR-guided vacuum-assisted breast biopsy. In 43 (16%) patients the indication was dropped because the lesions could not be identified at the time VB was scheduled. This was due to hormonal influences (n=37), to too strong compression (n=3) or to misinterpretation of the initial diagnostic MRI. In 5 cases (2%) VB was not performed due to obesity (n=2); problems of access (n=2) or a defect of the MR-unit (n=1). VB was performed on altogether 206 lesions. In 4 cases (2%) VB was unsuccessful. This was immediately realized on the post-interventional images. Thus a false negative diagnosis was avoided. Verification included excision of the cavity in cases with proven malignancy or atypical ductal hyperplasia (ADH) and (for benign lesions) retrospective correlation of VB-histology with pre- and postinterventional MRI and subsequent follow-up. Results: 51/202 successful biopsies proved malignancy. In 7 cases ADH and in 144 cases a benign lesion was diagnosed. One DCIS was underestimated as ADH. All other benign or malignant diagnoses proved to be correct. Conclusion: MR-guided VB allows reliable histological work-up of contrast-enhancing small lesions which are not visible by any other modality. (orig.) [German] Zielsetzung: Evaluation der Wertigkeit und klinischen Anwendbarkeit der MRT-gefuehrten Vakuumbiopsie (VB) bei anreichernden Mammalaesionen. Material und Methoden: Insgesamt wurden 254 Laesionen der MRT-gefuehrten VB zugewiesen. Hiervon entfiel bei 43 Patientinnen (16%) die Biopsieindikation beim Planungs-MRT, da die urspruengliche Anreicherung hormonell (n=37), durch zu starke Kompression (n=3) oder durch eine Fehlinterpretation des vorausgegangenen diagnostischen MRT (n=3) nicht mehr abgrenzbar war. Bei 5 weiteren Laesionen (2%) war die Biopsie nicht moeglich (Adipositas n=2; Zugangsprobleme n=2; MRT

  2. Value of noncontrast spiral CT for suspected acute appendicitis

    International Nuclear Information System (INIS)

    Choi, Pil Yeob; Lee, Sang Wook; Kwon, Jae Soo; Sung, Young Soon; Rho, Myoung Ho; Chang, Jeong A.

    1998-01-01

    To assess the diagnostic accuracy and clinical efficacy of noncontrast spiral CT in patients with suspected acute appendicitis. Over a six-month period, 100 patients with suspected acute appendicitis were prospectively evaluated with noncontrast spiral CT. All scans were obtained from the lower body of L3 to the symphysis pubis, with 5mm or 10mm collimation and pitch of 1 or 1.5, and without intravenous or oral contrast material. Diagnosis was established by means of surgical or clinical follow-up. Prospective diagnosis based on CT findings was compared with surgical results and clinical follow-up. Acute appendicitis was confirmed in 47 of 100 patients. On the basis of the Ct findings, SI patients were prospectively interpreted as positive for appendicitis, but in six the diagnosis was false-positive. Two of the 47 with acute appendicitis were prospectively interpreted as normal. The preoperative diagnosis of acute appendicitis was, thus, 45 true-positive, 47 true-negative, six false-positive and two false-negative yielding a sensitivity of 96%, a specificity of 89%, an accuracy of 92%, a positive predictive value of 88%, and a negative predictive value of 96%. Using CT, an alternative diagnosis was established in 14 patients. Noncontrast spiral CT is a useful technique for diagnosing acute appendicitis. =20

  3. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  4. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  5. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.; Klinische Neuroanatomie - kranielle MRT und CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanfermann, Heinrich; Raab, Peter [Medizinische Hochschule Hannover (MHH) (Germany). Inst. fuer Diagnostische und Interventionelle Neuroradiologie; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-07-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  6. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer; MRT-gezielte interventionelle Verfahren zur Abklaerung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Division fuer Molekulare und Gender-Bildgebung, Wien (Austria); Margreiter, M. [Medizinische Universitaet Wien, Univ.-Klinik fuer Urologie, Wien (Austria)

    2011-11-15

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [German] Neben dem transrektalen Ultraschall (TRUS) hat sich in den letzten Jahren die MRT als nichtinvasive Methode zur Bildgebung von Prostatatumoren etabliert. Mittels T2-gewichteter Sequenzen ist eine exakte anatomische Darstellung der Prostata und ihrer umliegenden Strukturen moeglich. Andere MRT-Techniken ermoeglichen Rueckschluesse auf das biologische Verhalten des Tumors: dynamische kontrastmittelverstaerkte T1-gewichtete Sequenzen zur Darstellung der Angiogenese, diffusionsgewichtete Aufnahmen zur Beurteilung der Zelldichte und die Spektroskopie zur Bestimmung von Gewebemetaboliten wie Cholin und Kreatin (multiparametrische Bildgebung). Prostatatumoren, die nur mittels MRT nachweisbar sind oder verdaechtige Tumoren, die hauptsaechlich anterior in der Prostata lokalisiert sind und in wiederholten TRUS-gezielten Biopsien verfehlt wurden, benoetigen eine MRT-gezielte Biopsie zur Diagnosesicherung. Die bisherigen

  7. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  8. Wertigkeit der Schnittbilddiagnostik in der Evaluation des pädiatrischen Schädel-Hirn-Traumas

    OpenAIRE

    Schäffeler, Christoph

    2010-01-01

    Die vorliegende Arbeit untersucht die diagnostische Wertigkeit von Computertomographie (CT) und Magnetresonanztomographie (MRT) in der Diagnostik des pädiatrischen Schädel-Hirn-Traumas. In einer retrospektiven Auswertung der Bildgebung von 64 Patienten im Alter von 0-15 Jahren wurden die Vor- und Nachteile der CT und MRT - Diagnostik bei der Darstellung intrakranieller Traumfolgen herausgearbeitet. Die Ergebnisse räumen der CT weiterhin einen hohen Stellenwert in der Akutdiagnostik ein, zeige...

  9. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  10. Postoperative and posttherapeutic changes after primary bone tumors. What's important for radiologists?; Postoperative und posttherapeutische Veraenderungen nach primaeren Knochentumoren. Was ist wichtig fuer den Radiologen

    Energy Technology Data Exchange (ETDEWEB)

    Grieser, T. [Klinikum Augsburg, Klinik fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Augsburg (Germany); Noebauer-Huhmann, I.M. [Med. Universitaet Wien, Univ.-Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2017-11-15

    Posttreatment imaging of primary bone tumours represents a diagnostic challenge for radiologists. Depending on the primary bone tumour common radiological procedures, such as radiography, computed tomography (CT), and magnetic resonance imaging (MRI), are employed. Radiography and CT are particularly useful in benign bone tumours and in matrix-forming bone tumours. MRI comes into consideration with malignant tumour recurrence and tumoral soft tissue infiltration. Bone scintigraphy is of superior importance if a primarily multifocal manifestation of bone tumour or metastasizing tumour disease is suspected. Molecular imaging (FDG-PET and hybrid imaging, using CT) are gaining increasing importance in light of monitoring neoadjuvant chemotherapy and detecting recurrent tumour appearance. The current literature shows sensitivity and specificity values for recurrent detection of up to 92% and 93%. Diagnostic accuracy is as high as 95%, thus, exceeding accuracy values for CT (67%) and MRI (86%) by far. Likewise, this is also applicable for the assessment of the neoadjuvant chemotherapy. Moreover, PET-based modalities are able to establish prognostic statements using SUV-threshold values at baseline (especially for Ewing sarcomas). Advanced imaging techniques have made a great diagnostic step forward and have proven to be relevant and reproducible with respect to both relapse detection and treatment assessment. Furthermore, it is not clear whether a higher detection rate of early tumour recurrence will inevitably lead to better outcome and survival. (orig.) [German] Die posttherapeutische Bildgebung primaerer Knochentumoren stellt eine diagnostische Herausforderung fuer jeden Radiologen dar. In Abhaengigkeit vom primaeren Knochentumor werden zur Nachsorge die gaengigen radiologischen Standardverfahren eingesetzt (Projektionsradiographie, Computertomographie [CT] und Magnetresonanztomographie [MRT]). Die Projektionsradiographie und CT haben einen besonderen Stellenwert v. a

  11. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Energy Technology Data Exchange (ETDEWEB)

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  12. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  13. Lung studies with spiral CT. pitch 1 versus pitch 2

    International Nuclear Information System (INIS)

    Sartoni Galloni, S.; Miceli, M.; Lipparino, M.; Burzi, M.; Gigli, F.; Rossi, M.S.; Santoli, G.; Guidarelli, G.

    1999-01-01

    In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality [it

  14. Importance of SPECT/CT for knee and hip joint prostheses; Stellenwert der SPECT/CT bei Knie- und Hueftgelenkprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Steurer-Dober, I.; Huellner, M.W.; Veit-Haibach, P.; Allgayer, B. [Luzerner Kantonsspital (Switzerland). Institut fuer Nuklearmedizin und Roentgendiagnostik

    2012-07-15

    Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal. (orig.) [German] Komplikationen wie Lockerung und Infekt stellen ein haeufiges Problem nach Hueft- und Kniegelenkprothesen dar. Wenn die konventionelle Roentgenaufnahme nicht zum Ziel fuehrt, ist die klassische konventionelle Skelettszintigraphie die am haeufigsten verwendete ''Second-line''-Bildgebung. Die ''single photon emission computed tomography''/CT (SPECT/CT) bietet metabolische und morphologische Informationen bzgl. Prothesenkomplikationen in einem Untersuchungsgang und ist zunehmend in groesseren Kliniken verfuegbar. Die SPECT/CT ist eine viel versprechende Methode und wird im klinischen Alltag bei der Evaluation von Gelenkprothesen zunehmend eingesetzt. Es sind noch mehr prospektive Studien noetig, um die Leistungsfaehigkeit und den Zusatznutzen gegenueber der klassischen Szintigraphie zu evaluieren. In unserer Klinik wird die Knochenszintigraphie bei der Abklaerung von Prothesenkomplikationen zumeist mit einer SPECT/CT kombiniert und liefert regelmaessig wichtige Zusatzinformationen. Die SPECT/CT entwickelt sich zunehmend zum Standard

  15. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  16. Optimising imaging parameters in experimental spiral CT

    International Nuclear Information System (INIS)

    Tiitola, M.; Vehmas, T.; Kivisaari, R.P.; Kivisaari, L.

    1997-01-01

    Purpose: This in vitro study was conducted to analyse lesion detection and relative radiation exposure in different CT techniques. Material and Methods: We used a plastic phantom (12 x 8 x 2 cm) containing holes filled with air or fluid of varying densities to simulate lesions. This was imaged with Siemens Somatom Plus S and GE High Speed Advantage units. We varied table feeds (3 and 6 mm/s in Siemens and 3 and 4.5 mm/s in GE) and increments (2 mm and 4 mm) while keeping collimation at 3 mm. The SmartScan program of GE and the reformating algorithm of Siemens were also analysed. To evaluate the different methods, the phatnom lesions were counted by 3 observers. Radiation exposures associated with each technique were also measured. Results: The images reformatted to a coronal direction were significantly inferior (p<0.01) to those in other techniques. The use of SmartScan did not influence lesion detection, nor did changes in pitch or increment. Spiral and non-spiral techniques proved to be equal. Radiation exposure was lowest when a greater pitch or the SmartScan program was used. Conclusion: Radiation exposure in CT can be limited without significantly impairing the image quality by using low-dose techniques. Reformatting to a coronal direction should be used with care as it debases the image quality. (orig.)

  17. MRI of pulmonary perfusion; MRT der Lungenperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Risse, F.; Semmler, W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische Physik in der Radiologie, Heidelberg (Germany); Schoenberg, S.O.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Kauczor, H.-U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany)

    2006-04-15

    Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion. (orig.) [German] Die Perfusion der Lunge ist eine entscheidende Voraussetzung fuer einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge fuer Diagnostik und Therapieplanung bedeutsam. Hierzu zaehlen neben Erkrankungen der Lungengefaesse wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengeruests und Lungentumoren. In diesem Beitrag werden die Moeglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt. (orig.)

  18. Spontaneous osteonecrosis of the knee joint: MR imaging before and after administration of gadopentetate-dimeglumine, comparison to CT, scintigraphy, and histology; Spontane Osteonekrose des Kniegelenkes: MRT im Vergleich zur CT, Szintigraphie und Histologie

    Energy Technology Data Exchange (ETDEWEB)

    Lang, P. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Grampp, S. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Vahlensieck, M. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Bonn Univ. (Germany); Mauz, M. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steiner, E. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Schwickert, H. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Universitaetsklinik Mainz (Germany); Gindele, A. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Felix, R. [Radiologische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Genant, H.K. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)

    1995-06-01

    Eight patients with spontaneous osteonecrosis of the knee joint underwent MR imaging before and after i.v. administration of Gd-DTPA. Nuclear scintigraphy was performed in all 8 patients, three patients also had CT scans of the knee area. Histologic correlation was available in three patients. Increased radionuclide uptake was observed in all patients. In one patient, however, scintigraphy showed increased radionuclide uptake consistent with ostenecrosis only in the medial femoral condyle, while MR imaging demonstrated osteonecrosis both in the medial as well as the lateral femoral condyles. MR demonstrated areas of low signal intensity on precontrast T{sub 1}-weighted images in the femoral condyle in all patients. All these areas showed high signal intensity on T{sub 2}-weighted images. On postcontrast T{sub 1}-weighted images, signal intensity increase was either homogeneous throughout the lesion or it was seen at the periphery of the lesion in a band-like pattern. Histologically, the areas of high signal intensity on T{sub 2}-weighted and on postcontrast T{sub 1}-weighted images corresponded to granulation tissue. (orig./MG) [Deutsch] Wir untersuchten acht Patienten mit einer spontanen Osteonekrose des Kniegelenkes mit der MRT. Ein Vergleich zum szintigraphischen Befund wurde bei allen 8 Patienten und zur CT bei drei Patienten angestellt. Eine histologische Korrelation war bei drei Patienten moeglich. Bei allen 8 Patienten zeigten die T{sub 1}-gewichteten MR-Tomographien Zonen mit reduzierter Signalintensitaet in den Kondylen, waehrend die Laesionen in den T{sub 2}-gewichteten Aufnahmen eine hoehere Signalintensitaet als das normale Knochenmark hatten. Nach Gabe von Gd-DTPA war entweder eine homogene Signalerhoehung oder eine bandfoermige Signalintensitaetszunahme in der Peripherie der Laesion zu sehen. Die Zonen mit hoher Signalintensitaet in der T{sub 2}-gewichteten Aufnahme oder mit Kontrastmittelanreicherung entsprachen histologisch Granulationsgewebe an der

  19. Clinical application of functional MRI for chronic epilepsy; Klinischer Einsatz der funktionellen MRT bei chronischer Epilepsie

    Energy Technology Data Exchange (ETDEWEB)

    Woermann, F.G.; Labudda, K. [Krankenhaus Mara, Epilepsiezentrum Bethel, Abteilung fuer Magentresonanztomographie, Bielefeld (Germany)

    2010-02-15

    Functional magnetic resonance imaging (fMRI) is frequently used in the presurgical diagnostic procedure of epilepsy patients, in particular for lateralization of speech and memory and for localization of the primary motor cortex to delineate the epileptogenic lesion from eloquent brain areas. fMRI is one of the non-invasive procedures in the presurgical diagnostic process, together with medical history, seizure semiology, neurological examination, interictal and ictal EEG, structural MRI, video EEG monitoring and neuropsychology. This diagnostic sequence leads either to the decision for or against elective epilepsy surgery or to the decision to proceed with invasive diagnostic techniques (Wada test, intra-operative or extra-operative cortical stimulation). It is difficult to evaluate the contribution of the fMRI test in isolation to the validity of the entire diagnostic sequence. Complications such as memory loss and aphasia in temporal lobe resections or paresis after frontal lobe resections are rare and rarely of disastrous extent. This further complicates the evaluation of the clinical relevance of fMRI as a predictive tool. In this article studies which investigated the concordance between fMRI and other diagnostic gold standards will be presented as well as the association between presurgical fMRI and postsurgical morbidity. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) wird im Rahmen der Epilepsiediagnostik vor epilepsiechirurgischen Eingriffen insbesondere zur Lateralisation von Sprache und Gedaechtnis und zur Lokalisation der Zentralregion eingesetzt, um den eloquenten Kortex von der epilepsieverursachenden, chirurgisch zugaenglichen Laesion abzugrenzen. Dabei ist die fMRT Teil einer Sequenz nichtinvasiver klinischer Tests (Anamnese, Anfall-Semiologie, neurologischer Status, interiktales und iktales EEG, strukturelles MRT, Video-EEG-Monitoring, Neuropsychologie). Das Ergebnis dieser Sequenz ist die Entscheidung fuer oder gegen einen

  20. Enhanced dual-phase spiral CT features of polypoid ampullary carcinoma

    International Nuclear Information System (INIS)

    Zeng Mengsu; Yan Fuhua; Zhou Kangrong; Chen Huiming; Chen Gang; Chen Jin

    2001-01-01

    Objective: To understand CT features of polypoid ampullary carcinoma by enhanced dual-phase spiral CT. Methods: 15 cases of polypoid ampullary carcinoma (PAC) confirmed by surgical and pathological results were studied with thin slice enhanced dual-phase spiral CT (including arterial and portal phase scanning)with retrospective analysis, the scanning parameters were 5 mm thickness and 1.0 pitch for arterial phase scanning, and 5 mm thickness and 5 mm space for portal phase scanning. Results: All cases could display an enhanced mass as local filling defect at the site of the duodenal Vater's ampulla during arterial and portal phase scanning, the tumors ranged in size from 1 cm to 5 cm with mean of 2.3 cm, all were accompanied with dilated intrahepatic and common bile duct, enlarged gallbladder and dilated pancreatic duct, except one case which had marked atrophy of the pancreatic body and tail. Conclusion: The thin slices enhanced dual-phase spiral CT could not only accurately define the level of obstruction, but also demonstrate an enhanced mass as direct CT sign of the PAC, which is crucial for diagnosis of the PAC

  1. Pulmonary spheral tuberculosis: features and clinical significance of spiral dynamic CT

    International Nuclear Information System (INIS)

    Xie Ruming; Ma Daqing; Li Tieyi; Chen Yi; Lu Fudong; Zhou Xinhua

    2001-01-01

    Objective: To assess the features and clinical significance of spiral dynamic CT in patients with pulmonary spheral tuberculosis. Methods: The 54 foci in 42 patients with pulmonary spheral tuberculosis were studied. Thin-sections at 2 mm thickness and 2 mm interval through the nodular center were obtained before and after administration of contrast material. Results: In 54 pulmonary spheral tuberculosis, maximum enhanced CT value in 51 (94.4%, 51/54) foci was less than 20 HU, and more than 20 HU in the other 3(5.6%, 3/54) foci. 27(50.0%, 27/54) foci showed no any enhancement, 24, (44%, 24/54) foci showed capsular enhancement, 1(1.9%, 1/54) focus showed peripheral enhancement and 2(3.7%, 2/54) foci showed extensive enhancement. The accuracy of the correct diagnosis was 25.9% in terms of plain CT and 94.4% in terms of enhanced CT scanning. The difference was significant (x 2 = 50.1, P < 0.05). The curative effect of extensive enhanced foci and peripheral enhanced foci was optimal, capsular enhanced foci was second, and non-enhanced foci was barely satisfactory. Conclusion: Spiral dynamic CT technique may improve the accuracy of diagnosing pulmonary spheral tuberculosis. No enhancement and/or capsular enhancement were suggestive of tuberculosis. The enhancing character of foci might contribute to assess the curative effect of anti-tuberculosis

  2. Magnetic resonance angiography and tomography of vertebrobasilar dissections; Magnetresonanzangiographie und Magnetresonanztomographie bei Dissektionen der A. vertebralis

    Energy Technology Data Exchange (ETDEWEB)

    Felber, S. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria)]|[Universitaetsklinik fuer Radiologie, Klinische Abt. 2, Universitaetskliniken Innsbruck (Austria); Auer, A. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria); Schmidauer, C. [Universitaetsklinik fuer Neurologie, Universitaetskliniken Innsbruck (Austria); Waldenberger, P. [Universitaetsklinik fuer Radiologie, Klinische Abt. 1, Universitaetskliniken Innsbruck (Austria); Aichner, F. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria)

    1996-11-01

    wichtige Ursache von Schlaganfaellen bei juengeren Erwachsenen. Wir untersuchten die diagnostischen Moeglichkeiten der Magnetresonanzangiographie (MRA) in Kombination mit der Magnetresonanztomographie (MRT) bei vertebrobasilaeren Dissektionen anhand einer retrospektiven Analyse von 24 Patienten mit einer Vertebralisdissektion und einem Patienten mit einer Basilarisdissektion. Bei 24 von 25 Patienten (95,5%) wurden mit der Magnetresonanzangiographie abnorme Flussverhaeltnisse im disseziierten Gefaess erkannt. Die Sensitivitaet der konventionellen Angiographie war 100% und die des Ultraschalls 77%. In 7 Faellen (30,4%) ergab die Magnetresonanz spezifische Hinweise auf eine Dissektion (Doppellumen n=1, murales Haematom n=4, Pseudoaneurysma n=2). Demgegenueber standen 36,4% spezifische Befunde in der Angiographie. Dabei waren die spezifischen Resultate von MRT/MRA und Angiographie z.T. komplementaer, beide Methoden zusammen erzielten 43,5% Spezifitaet. Die kombinierte MRT und MRA kann bei etwa 1/3 der Patienten bereits die Diagnose einer Vertebralisdissektion stellen. Bei den anderen Patienten kann die Indikation zur konventionellen Angiographie verbessert werden. Dies gilt besonders fuer jene Patienten mit unspezifischen Prodromalsymptomen. Eine negative Magnetresonanzuntersuchung erzetzt bei Patienten mit hinweisenden Symptomen die konventionelle Angiographie allerdings nicht. Die Angiographie wird aufgrund der hoeheren Ortsaufloesung und der sicheren Beurteilbarkeit auch des proximalen V Abschnittes 1 vorerst diagnostischer Standard bleiben. (orig.)

  3. Efficacy of spiral CT in the evaluation of peritoneal seeding of gastric cancer

    International Nuclear Information System (INIS)

    Choi, Hyuck Jae; Han, Joon Koo; Kim, Tae Kyoung; Kim, Ah Young; Lee, Joon Woo; Moon, Min Hoan; Yang, Han Kwang; Choi, Byung Ihn

    2001-01-01

    To determine usefulness of spiral CT in the preoperative evaluation of peritoneal seeding from a gastric carcinoma. From a database of 411 consecutive patients with surgically proven advanced gastric cancinoma obtained over a six-month period, 17 with peritoneal seeding and a control group of 24 without peritoneal seeding underwent spiral CT scanning with 7-8 mm scan thickness and interval during the portal phase. Preoperative CT images were analyzed by two readers who reached a consensus with regard to the presence and location of the ascites, thickening of the parietal peritoneum, and changes in the omentum and mesentery. Ascites was present in 47% (8/17) of patients with peritoneal seeding the right subhepatic space (n=6, 35%) and right paracolic gutter (n=5, 29%)-but not the cul-de-sac (n=2, 12%)-were common sites of fluid collection. Permeative changes in the omentum and mesentery were seen in 18% (3/17) and 12% (2/17) of patients, respectively. Among five controls with false positive results, ascites in the cul-de-sac was present in three (two males and one female, 12%) while omental nodules and a thickened peritoneum were found in two (8%) and one (4%), respectively. In nine controls with false negative results, small disseminated nodules were seen in the mesentery and omentum at surgical field. The sensitivity and specificity of spiral CT were 47% (8/17) and 79% (19/24), respectively. In terms of sensitivity and specificity, spiral CT is not especially accurate in distinguishing peritoneal seeding from gastric carcinoma

  4. The role of spiral CT in pelvic trauma management

    International Nuclear Information System (INIS)

    Cheung, E.C.F.; Fung, K.K.L.

    1999-01-01

    Rapid and accurate assessment of pelvic injury is critical for good patient management. Plain X-ray is often used as a preliminary evaluation of the injury but this may not give adequate diagnosis of the acetabulum fracture, subtle fracture of the pelvic bone and the associated soft tissue injuries. Nowadays, spiral CT has taken an increasing role in the evaluation of pelvic trauma. It gives a rapid assessment of the bone and soft tissue injuries as compared to conventional CT. Besides, 2-D (multiplanar imaging) and 3-D image reconstruction with multiple angle views, provide the maximum information which facilitates detailed pelvic trauma evaluation. Three cases were used to illustrate the role of spiral CT in pelvic trauma management. Copyright (1999) Blackwell Science Pty Ltd

  5. Sacroiliitis in children with spondyloarthropathy: therapeutic effect of CT-guided intra-articular corticosteroid injection; Sakroiliitis bei Kinder mit Spondylarthropathie: Therapeutischer Effekt der CT-gestuetzten intraartikulaeren Kortikosteroid-Injektionen

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, T.; Hermann, K.G.A.; Diekmann, F.; Hamm, B. [Humboldt-Universitaet, Berlin (Germany). Universitaetsklinikum Charite, Inst. fuer Radiologie; Biedermann, T. [HELIOS Klinikum Berlin (Germany). II. Klinik fuer Kinderheilkunde und Jugendmedizin, Abt. Kinderrheumatologie; Braun, J. [Rheumazentrum Ruhrgebiet, St. Josefs-Krankenhaus (Germany); Bollow, M. [Augusta-Krankenhaus, Bochum (Germany). Inst. fuer Radiologie

    2003-06-01

    . The follow-up dynamic MRI (0.1 mmol/kg body weight) during therapy showed a statistically significant lower contrast-enhancement in both groups (group 1: 117{+-}43% versus 38{+-}24%, p<0.05; group 2: 127{+-}59% versus 38{+-}22%, p<0.05). One third of the patients of group 2 showed progression of joint destruction despite absence of subjective complaints. (orig.) [German] Ziel: Prospektive Pruefung des therapeutischen Effektes der CT-gesteuerten intraartikulaeren Kortikosteroid-Injektion entzuendlicher Sakroiliakalgelenke (SIG) bei Kindern mit juveniler Spondylarthropathie (jSpA) im Vergleich zur konventionellen Therapie mit nichtsteroidalen Antirheumatika (NSAR) sowie Bestimmung der Wertigkeit der Magnetresonanztomographie (MRT) bei der Indikationsstellung und der Therapieverlaufskontrolle. Material und Methode: Bei 89 Kindern mit bekannter jSpA wurden mittels dynamischer MRT uni- oder bilaterale Sakroiliitiden diagnostiziert. Bei allen 89 Patienten wurde daraufhin eine Therapie mit NSAR eingeleitet bzw. bereits bestehende Therapien fortgesetzt. Vier Wochen nach der diagnostischen MRT wurden zwei Gruppen definiert: 33 Patienten mit klinischem Response auf NSAR (Gruppe 1) und 56 Nonresponder (Gruppe 2). Die Patienten der Gruppe 2 wurden unter Belassung der NSAR zusaetzlich einer CT-gestuetzten (Low-Dose-Technik) intraartikulaeren Kortikosteroid-Injektion zugefuehrt, wobei insgesamt 83 SIG punktiert und infiltriert wurden (27 bilateral, 29 unilateral). Die Indikationsstellung zur Intervention beruhte auf der zuvor MR-tomographisch gesicherten Entzuendungsaktivitaet. Klinische Therapieverlaufskontrollen erfolgten in 8- bis 12-woechigen Intervallen ueber einen Zeitraum von 20 Monaten. MRT-Verlaufskontrollen wurden bei allen 56 Kindern der Gruppe 2 und bei 15 von 33 Kindern der Gruppe 1 in einem Zeitraum von 8{+-}4 Monaten nach der Erstuntersuchung durchgefuehrt. Ergebnisse: Ingesamt 87,5% der komplikationslos punktierten Kinder der Gruppe 2 (Standardtherapie

  6. Follow-up and prognosis of thyroid carcinoma; Nachsorge und Prognose der Schilddruesenkarzinome

    Energy Technology Data Exchange (ETDEWEB)

    Sandrock, D.; Munz, D.L. [Humboldt-Universitaet, Berlin (Germany). Medizinische Fakultaet Charite

    2000-03-01

    The follow-up of patients with differentiated thyroid carcinoma is based on guidelines of the appropriate scientific societies like the German Society of Nuclear Medicine (DGN). After (successfull) radioiodine treatment there are follow-up investigations in intervalls (every [half] year, life-long) including ultrasound, serum level of thyroglobulin, TSH, (f)T3, and (f)T4. If recurrent/metastatic disease is suspected further special methods will follow (radioiodine scan, CT, MRI..). 5- and 10-year overall survival rates of paillary carcinoma are in the range of 90% and 80%, of follicular carcinoma in the range of 80% and 70%, respectively. Individual prognosis can be assessed by different scoring systems including factors like age, sex, size, grading, and extent of the disease. The medullary carcinoma has a mediocre prognosis and similar follow-up intervals focusing on the tumor markers calcitonin and CEA and, if necessary, a variety of imaging methods. The anaplastic carcinoma with its bad prognosis needs individual (palliative) symptomatic follow-up. (orig.) [German] Die Nachsorge des differenzierten Schilddruesenkarzinoms orientiert sich an Empfehlungen und Leitlinien der DGN sowie weiterer Fachgesellschaften. Nach (erfolgreicher) Therapie sind in Intervallen (1/2jaehrlich, jaehrlich, lebenslang) ambulante Nachsorgeuntersuchungen mit Sonographie, Thyreoglobulin- und TSH-, [f]T3-, [f]T4-Bestimmung erforderlich. Je nach Rezidiv-/Metastasenverdacht sind gezielte weitere Untersuchungen durchzufuehren (Radiojoddiagnostik, CT, MRT...). Die 5- und 10-Jahres-Ueberlebensraten des papillaeren Karzinoms liegen um 90% bzw. 80%, die des follikulaeren um 80% bzw. 70%. Die Prognose kann mittels diverser Scores bestimmt werden, die u.a. Alter, Geschlecht, Grading, und Ausdehnung der Erkrankung beruecksichtigen. Das medullaere Karzinom hat bei mittlerer Prognose aehnliche Nachsorgeintervalle, orientiert sich an den Tumormarkern Kalzitonin und CEA und gegebenenfalls komplexer

  7. MR imaging in congenital complicated anterior body wall defects; MRT von komplizierten angeborenen Bauchwanddefekten

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, M.; Scharitzer, M. [Universitaetsklinik fuer Radiodiagnostik, AKH-Wien (Austria); Pumberger, W. [Universitaetsklinik fuer Kinderchirurgie, AKH-Wien (Austria); Patzak, B. [Pathologisch-anatomisches Museum im Narrenturm, AKH-Wien (Austria)

    2003-04-01

    Introduction: Aim of this study was to estimate the value of postmortem MR imaging in evaluation of specimen with congenital anterior body wall defects of the museum of pathologic-anatomy. Material and Methods: We examined 19 specimen with a 1.5 Tesla unit by using T{sub 1}- and T{sub 2}-weighted sagittal and coronal sequences. In some specimen additional axial T{sub 2}-weighted images were obtained. We evaluated the site of the bowel, the liver, the heart and presence of associated disorders. Results: The bowels were completely intraabdominal, in two specimen, completely extraabdominal in 12 specimen and in 5 specimen intra- and extraabdominal. The liver was in two specimen completely extraabdominal/in 12 completely intracorporal, and in 5 specimen intra- and extraabdominal. In 5 cases the heart was located extraanatomically. In 12 specimen we found disorders of the spine and the extremities. Congenital disorders of the kidneys were found in 6 specimen. Conclusion: MR imaging is of great value in the assessment of congenital anterior body wall defects. In the light of ultrafast sequences the role of fetal MR imaging in the evaluation of congenital body wall defects may be mandatory in the future. (orig.) [German] Einleitung: Wir nutzten die Sammlung des pathologisch-anatomischen Museums in Wien, um die Wertigkeit der MRT zur Beschreibung von angeborenen vorderen Bauchwanddefekten und deren assoziierten Erkrankungen zu bestimmen. Material und Methode: Wir untersuchten 19 Exponate mit einem 1,5-Tesla-Geraet unter Verwendung von sagittalen und koronalen T{sub 1}- und T{sub 2}-gewichteten Sequenzen. Ausgewertet wurden die Lage des Darmes, der Leber, des Herzens und assoziierte Missbildungen. Ergebnisse: Der Darm lag in zwei Faellen intraabdominal, zur Gaenze extraabdominal in 12 Faellen, intra- und extraabdominal in 5 Faellen. Die Leber war in zwei Exponaten zur Gaenze extraabdominal, in 5 intra- und extraabdominal und in 12 Exponaten intraabdominal. Assoziiert waren

  8. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  9. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  10. Intraoperative appearance of the resection area in brain-tumor operations in an open 0,5 MRT; Intraoperatives Erscheinungsbild des Resektionsbereichs bei Hirntumoroperationen in einem offenen 0,5-T-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, J. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany). Arbeitsbereich Neuroradiologie; Schneider, J.P.; Schulz, T. [Universitaetsklinik fuer Diagnostische Radiologie, Leipzig (Germany); Seifert, V.; Trantakis, C. [Universitaetsklinik fuer Neurochirurgie, Leipzig (Germany); Kellermann, S. [Leipzig Univ. (Germany). Abt. fuer Neuropathologie

    1998-11-01

    During MRI-controlled resection of brain tumors using an open MRI system, operation-induced alterations may occur, especially enhancement of the resection cavity wall. This may simulate tumor areas, resulting in false assessment of the resection or resection of non-tumorous areas. Based on 42 MRI- and biopsy-controlled brain tumor resections in an 0.5 T open MRI (Signa SP, GE), the appearance and origin of operation-induced reactions are analyzed. In our opinion, there is a superposition of preformed peritumoral reactions by operation-induced microcontusions. The beginning of the cavity wall enhancement needs at least 10-15 min. MRI-controlled analysis of the intraoperative steps by the neurosurgeon and neuroradiologist allows discrimination of operation-induced reactions from tumor areas and leads to safe operation. (orig.) [Deutsch] Bei der intraoperativen Kontrolle von Hirntumorresektionen in offenen MRT-Geraeten kann es zu operativ induzierten Veraenderungen, insbesondere Rand-enhancement-Zonen, kommen. Diese koennen Tumorreste vortaeuschen, so dass die Radikalitaet des Eingriffs unterschaetzt wird oder nicht tumortragende Hirnareale entfernt werden. Ergebnisse und Diskussion: Anhand von 42 in einem offenen 0,5-T-MRT (Signa SP, GE) vorgenommenen, biopsiekontrollierten Hirntumoroperationen werden Erscheinungsbild und Entstehungsweise der Randveraenderungen analysiert. Bei den haeufig vorzufindenden Rand-enhancement-Zonen handelt es sich um eine Ueberlagerung von praeformierten Tumorrandreaktionen mit Mikrokontusionen. Die Ausbildung dieser Veraenderungen braucht eine Mindestzeit von 10-15 min. Die staendige Analyse der die Tumorresektion begleitenden MRT-Kontrollen durch den Operateur und einen mit der Problematik vertrauten Radiologen gestattet in der Regel die Differenzierung der operativ induzierten Veraenderungen und erhoeht damit die Sicherheit des Eingriffs. (orig.)

  11. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  12. Pulmonary sequestration: diagnosis with three dimensional reconstruction using spiral CT

    International Nuclear Information System (INIS)

    Nie Yongkang; Zhao Shaohong; Cai Zulong; Yang Li; Zhao Hong; Zhang Ailian; Huang Hui

    2003-01-01

    Objective: To evaluate the role of three dimensional (3D) reconstruction using spiral CT in the diagnosis of pulmonary sequestration. Methods: Ten patients with pulmonary sequestration were analyzed. The diagnoses were confirmed by angiography in 2 patients, by operation in 2 patients, and by CT angiography in 6 patients. All patients were examined with Philips SR 7000 or GE Lightspeed Plus scanner. CT images were transferred to a workstation and 3D reconstruction was performed. All images were reviewed and analyzed by two radiologists. Results: Among 10 patients, the pulmonary sequestration was in the right lower lobe in 1 patient and in the left lower lobe in 9 patients. Anomalous systemic arteries originated from thoracic aorta in 8 patients and from celiac artery in 2 patients. On plain CT scan, there were 4 patients with patchy opacities, 3 patients with hilar mass accompanying vascular engorgement and profusion in adjacent parenchyma, 2 patients with finger-like appendage surrounded by hyper-inflated lung, and 1 patient with lung mass-like lesion. Enhanced CT revealed anomalous systemic arteries in 9 patients and drainage vein in 7 patients. Maximum intensity projection (MIP) and curvilinear reconstruction could depict the abnormal systemic artery and drainage vein in sequestration. Surface shadow display (SSD) and volume rendering (VR) could delineate the anomalous systemic artery. Conclusion: 3D reconstruction with enhanced spiral CT can depict anomalous systemic artery and drainage vein and it is the first method of choice in diagnosing pulmonary sequestration

  13. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  14. Fetal magnetic resonance imaging of thoracic and abdominal malformations; Fetale Magnetresonanztomographie thorakaler und abdomineller Malformationen

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, R.; Asenbaum, U.; Furtner, J.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Brugger, P.C. [Medizinische Universitaet Wien, Zentrum fuer Anatomie und Zellbiologie, Wien (Austria)

    2013-02-15

    Diagnosis and differential diagnosis of fetal thoracic and abdominal malformations. Ultrasound and magnetic resonance imaging (MRI). In cases of suspected pathologies based on fetal ultrasound MRI can be used for more detailed examinations and can be of assistance in the differential diagnostic process. Improved imaging of anatomical structures and of the composition of different tissues by the use of different MRI sequences. Fetal MRI has become a part of clinical routine in thoracic and abdominal malformations and is the basis for scientific research in this field. In cases of thoracic or abdominal malformations fetal MRI provides important information additional to ultrasound to improve diagnostic accuracy, prognostic evaluation and surgical planning. (orig.) [German] Diagnose und Differenzialdiagnose fetaler thorakaler und abdomineller Malformationen. Ultraschall, MRT. MRT zur weiteren Abklaerung und genaueren Differenzierung bei vielen im Ultraschall gestellten Verdachtsdiagnosen. Verbesserte anatomische Darstellung mittels MRT und Darstellung unterschiedlicher Gewebezusammensetzung mittels verschiedener MR-Sequenzen. Die fetale MRT ist bei der angegebenen Fragestellung in die klinische Routine eingegangen und liefert weiterhin die Basis fuer wissenschaftliche Untersuchungen in diesem Bereich. Die fetale MRT liefert beim Vorliegen thorakaler oder abdomineller Malformationen komplementaer zum Ultraschall wichtige Zusatzinformationen, um die diagnostische Genauigkeit zu erhoehen, die Prognoseabschaetzung zu verbessern und ggf. eine bessere chirurgische Planung zu ermoeglichen. (orig.)

  15. Improvement in printing technique of spiral CT three-dimensional colour image

    International Nuclear Information System (INIS)

    Wang Yicheng; Liu Feng; Zhang Ling

    2005-01-01

    Objective: To investigate the printing technique of spiral CT three-dimensional (3D) colour image. Methods: The 3D colour images of 136 patients were printed, with the equipment of Marconi spiral CT, personnel computer, colour ink printer, and network switchboard. Results: All printed images were satisfied by this method. Conclusion: This technique is economic, simple, and useful, and can meet the need for clinical diagnosis and operation. (authors)

  16. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  17. Functional MR imaging of the patellofemoral joint; Funktionelle MRT des Femoropatellargelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Kiel Univ. (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Kiel Univ. (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Kiel Univ. (Germany)

    1995-02-01

    Conventional X-ray examinations of the patellofemoral joint in 30 , 60 and 90 of knee flexion demonstrate the position of the patella. On the other hand, they have been shown to be insufficient for the diagnosis of patellofemoral maltracking in the critical range between 30 of flexion and full extension. Motion-triggered and ultrafast MRI offer new possibilities for functional diagnosis of the patellofemoral joint under active knee motion. Functional MRI of the patellofemoral joint is suggested as an alternative to arthroscopy, particularly in patients with anterior knee pain or suspected patellar maltracking. (orig.) [Deutsch] Tangentialaufnahmen der Patella in 30 -, 60 - und 90 -Kniebeugung koennen zwar die Lage der Kniescheibe im Femoropatellargelenk darstellen, sie erlauben jedoch keine Aussage ueber die funktionellen Aspekte des Patellagleitens zwischen 30 -Beugung und 0 -Streckung. Dieser fuer die Kniescheibenfuehrung kritische, mittels der konventionellen Roentgentechnik (aufgrund von Femur- und Patellaueberlagerung) nicht einsehbare Bereich, kann unter aktiver Kniestreckung mit der funktionellen MRT dargestellt werden. Durch bewegungsgetriggerte Gradientenechosequenzen oder neuerdings auch durch ultraschnelle Bildsequenzen ist es moeglich, funktionelle Informationen ueber das Patellagleiten in der endgradigen Streckenbewegung zu erhalten. Die funktionelle MRT des Femorpatellargelenkes bietet daher z.B. fuer die Abklaerung von unklaren, vorderen Kniegelenksbeschwerden und bei der Frage nach Patellagleitwegsstoerungen eine Alternative zur diagnostischen Arthroskopie. (orig.)

  18. Initial clinical experience with spiral CT angiography in the abdomen

    International Nuclear Information System (INIS)

    Gaa, J.; Stehling, M.K.; Costello, P.

    1993-01-01

    The latest developments in modern CT instruments, offering scanning times of a second, opened up new possibilities in CT imaging in combination with the spiral technique. The data set normally taken with single-breath-hold technique is free of respiratory artefacts and thus is a good basis for accurate 3D image reconstruction. Spiral CTA allows a non-invasive 3D imaging of various blood vessels. Patients with abdominal aortic aneurysms of aorto-iliac bypass can be examined as outpatients within 15 minutes. (orig.) [de

  19. [Application of Low Dose Spiral CT in Diagnosing Impacted Teeth in Children and Adolescents].

    Science.gov (United States)

    Wang, Meng-tian; Li, Xue-sheng; Li, Kai-ming; Bao, Li; Ning, Gang

    2015-09-01

    [ABSTRACT] To determine the value of low dose spiral CT scanning in diagnosing impacted teeth of children and adolescents. A total of 153 children and adolescents with confirmed impacted teeth in West China Second University Hospital, Sichuan University were enrolled in this study. They were divided into 5 groups according to the different spiral CT scan parameters (tube current time product, scanning thickness and collimation value): Group A (n=30, 330 mAs, 6 X 0. 75 mm and 3. 0 mm), Group B (n=30, 140 mAs, 6 X 0. 75 mm and 3. 0 mm), Group C (n=30, 80 mAs, 6 X 0. 75 mm and 3. 0 mm), Group D (n=31, 80 mAs, 6 X 1. 50 mm and 5. 0 mm), and Group E (n=32, 50 mAs, 6 X 1. 50 mm and 5. 0 mm). There were no significant differences in general clinical features (P>0. 05) among the participants of the five groups. The phantoms were used to measure spatial resolution and contrast resolution of the scan images. Dose length product (DLP) was recorded during CT scanning for calculating effective dose (ED) of exposure. The quality of images was evaluated using a list of quality scoring criteria. (1) Under 330, 140, 80, 80 and 50 mAs, the images had a spatial resolution of 1.0 mm, with contrast resolution of 2. 0, 3. 0, 4. 5, 4. 5 and 6. 0 mm, respectively. (2) Significant differences in ED values were found among the five groups (F=1 064. 119, P=0. 000) and between every two of those groups (P0. 05). The diagnostic results of the spiral CT were consistent with those of orthodontic surgery. Low dose spiral CT scanning can meet the image quality requirements for diagnosing impacted teeth, minimizing radiation exposure effectively.

  20. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  1. Clinical application of 16-slice spiral CT in reconstruction imaging of coronary artery for diagnosing coronary disense

    International Nuclear Information System (INIS)

    Mao Xinbo; Zhu Xinjin; Zeng Huiliang; Chen Xueguang

    2005-01-01

    Objective: An evaluation of the reconstructed imaging of coronary arteries with 16-slice spiral CT in diagnosis of coronary disease. Methods: The reconstructed images of coronary arteries obtained on a 16-slice spiral CT scanner were reviewed in 60 cases, on which the following techniques were applied: retrospective ECG-gating, Segment method with 75% R-R interval, volume rendering technique (VRT), maximum intensity projection (MIP), mulfiplanar reconstruction (MPR), curved planar reconstruction (CPR) and CT virtual endoscopy (CTVE). Results: In all 60 cases, different stages of CHD were revealed in 21 cases; none abnormality was found in 33; and images were in poor quality in 2 cases, which was available for diagnosis. There were 4 stents planted in 4 cases: soft plaque suspected in lcase, patent in 2 and occlude in 1. Conclusion: The reconstructed imaging of coronary arteries with 16-slice spiral CT is superior modality in evaluation of severe coronary stenosis, plaques, and the pantency of the intra-luminal stents, which is an efficient and non-invasive imaging in diagnosis of early-stage CHD and screening in high risk population. (authors)

  2. Spiral CT scanning plan to generate accurate Fe models of the human femur

    International Nuclear Information System (INIS)

    Zannoni, C.; Testi, D.; Capello, A.

    1999-01-01

    In spiral computed tomography (CT), source rotation, patient translation, and data acquisition are continuously conducted. Settings of the detector collimation and the table increment affect the image quality in terms of spatial and contrast resolution. This study assessed and measured the efficacy of spiral CT in those applications where the accurate reconstruction of bone morphology is critical: custom made prosthesis design or three dimensional modelling of the mechanical behaviour of long bones. Results show that conventional CT grants the highest accuracy. Spiral CT with D=5 mm and P=1,5 in the regions where the morphology is more regular, slightly degrades the image quality but allows to acquire at comparable cost an higher number of images increasing the longitudinal resolution of the acquired data set. (author)

  3. Neurofunctional MRI at high magnetic fields; Neurofunktionelle MRT bei hohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Speck, O. [Fakultaet fuer Naturwissenschaften, Otto-von-Guericke Universitaet Magdeburg, Abteilung Biomedizinische Magnetresonanz, Institut fuer Experimentelle Physik, Magdeburg (Germany); Leibniz Institut fuer Neurobiologie, Magdeburg (Germany); Deutsches Zentrum fuer Neurodegenerative Erkrankungen (DZNE), Magdeburg (Germany); Center for Behavioral Brain Sciences (CBBS), Magdeburg (Germany); Turner, R. [MPI fuer Kognitions- und Neurowissenschaften, Abteilung Neurophysik, Leipzig (Germany)

    2013-05-15

    group data without the need for voxel-based congruence. (orig.) [German] fMRT-Untersuchungen sind durch den geringen aktivierungsinduzierten Signalunterschied in ihrer Sensitivitaet limitiert und innerhalb kurzer tolerierbarer Messzeiten ist die raeumliche Aufloesung limitiert. fMRT bei 1,5 und mehr noch bei 3 T ist ein zuverlaessiges Werkzeug in der Neurowissenschaft und fuer klinische Anwendungen, wie etwa die praechirurgische Funktionslokalisierung. Die fMRT-Sensitivitaet steigt stark (mehr als linear) mit hoeherer Magnetfeldstaerke. Dies war seit Jahren einer der Hauptgruende fuer die Entwicklung zu hoeheren Feldern wie etwa 7 T. Der Sensitivitaetsgewinn von 7 gegenueber 3 T ist bei hoher raeumlicher Aufloesung am groessten und die fMRT mit sehr hoher isotroper Submillimeteraufloesung wird moeglich. Bisherige Resultate zeigen, dass die Blood-oxygenation-level-dependent(BOLD)-Lokalisierung deutlich praeziser ist als bislang angenommen. Mittels Hochfeld-fMRT werden nicht nur quantitativ bessere Ergebnisse erzielt, sondern Informationen neuer Qualitaet zugaenglich wie etwa die kolumnare und schichtabhaengige Struktur des Kortex. Somit wird der Weg zu weiteren Informationen, wie etwa die Richtung kortikaler Verbindungen, eroeffnet. Diese Moeglichkeiten bergen jedoch auch neue Herausforderungen. So muessen neue Verfahren zur Prozessierung derart hochaufgeloester Daten entwickelt werden, welche z. B. ohne Glaettung auskommen, um den Informationsgehalt der Daten nicht zu reduzieren. Standardaufloesungen von 2-3 mm sind weiterhin bei 3 T ''gut aufgehoben'' und profitieren von geringeren Signalausloeschungen, weniger Verzerrungen und geringerer Lautstaerke. Zum Erreichen hoechster Aufloesung bei 7 T sind parallele Bildgebung und Verzerrungskorrektur essenziell und ermoeglichen eine gute Uebereinstimmung mit anatomischen Aufnahmen. Die Echozeit sollte bei 7 T auf ca. 20-25 ms angepasst und die Datenauswertung fuer einzelne Probanden oder Patienten ohne

  4. Effect of the degree of sternal depression on the cardiac rotation in pectus excavatum: evaluation with spiral CT

    International Nuclear Information System (INIS)

    Yu Jianqun; Yang Zhigang; Li Zhenlin; Guo Yingkun; Lu Chunyan; Zhang Mei

    2004-01-01

    Objective: To evaluate the effects of the degree of sternal depression on the cardiac rotation in pectus excavatum by using spiral CT. Methods: Spiral CT features of 32 patients with surgically corrected pectus excavatum were retrospectively reviewed. They included 27 males and 5 females ranging in age from 6 months to 17 years (mean, 6.3 years). Analysis was based on relationship among the degree of sternal depression, CT depression index, cardiac rotation angle, and PV angle. Results: 32 cases of pectus excavatum presented the sternal depression (21 ± 7) mm, CT depression index 2.9 ± 1.8, cardiac rotation angle (55.9 ± 9.8) degree, and PV angle (49.8 ± 14.0) degree, respectively. The sternal depression (17 mm) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (21 mm) and CT depression index larger than 2.9 (27 mm) (F 5.39, P<0.01). Cardiac rotation angle (49.7 degree) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (55.5 degree) and CT depression index larger than 2.9 (66.9 degree) (F=7.44, P<0.01). PV angle (58.7 degree) in cases with CT depression index less than 2.4 was larger than those with CT depression index 2.4-2.9 (46.5 degree) and CT depression index more than 2.9 (42.4 degree) ( F=3.33, P<0.05). Cardiac rotation angle of pectus excavatum had positive correlation with the CT depression index (γ=0.73, P<0.01). Conclusion: Spiral CT is a better tool for revealing chest deformity and corresponding cardiac rotation. The degree of sternal depression in pectus excavatum directly influences the cardiac rotation, and they had positive correlation. (authors)

  5. Acquired CNS lesions in fetal MRI; Erworbene ZNS-Laesionen im fetalen MRT

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Pogledic, I. [Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2013-02-15

    Acquired central nervous system (CNS) lesions are often subtle; therefore, the prenatal diagnosis of these lesions is extremely important. The fetal ultrasound examination and magnetic resonance imaging (MRI) are two important imaging methods that give an insight into these types lesions. The method of choice during pregnancy is still fetal ultrasound; however, fetal MRI is important when there are certain pathologies, e.g. periventricular leukomalacia (PVL) or malformations of the vein of Galen. In this manner clinicians can plan further therapy after childbirth in advance (e.g. cerebral angiography or embolization). (orig.) [German] Die erworbenen ZNS-Laesionen sind oft subtil, und eine praezise praenatale Diagnostik ist in diesen Faellen besonders wichtig. Die fetale Sonographie und das fetale MRT koennen hierzu einen relevanten Beitrag leisten. Die Sonographie ist immer noch die Untersuchungsmethode der Wahl waehrend der Schwangerschaft. Insbesondere bei bestimmten Pathologien wie der periventrikulaeren Leukomalazie (PVL) oder einer V. -Galeni-Malformation ist das fetale MRT sehr hilfreich, um nach der Geburt die entsprechenden weitergehenden Massnahmen, wie eine zerebrale Angiographie und Embolisation, fruehzeitig zu planen. (orig.)

  6. The experimental study on bowel ischemia in closed loop obstruction by using multi-phase spiral CT

    International Nuclear Information System (INIS)

    Zhang Xiaoming; Yang Hanfeng; Huang Xiaohua; Tang Xianying; Jian Pu; Yang Zhengwei; Zhou Jiyong; Zhao Zongwen

    2005-01-01

    Objective: To evaluate the bowel ischemia in experimental closed loop obstruction by using multi-phase spiral CT. Methods: Twenty-four New Zealand rabbits of both sexes (mean age, 4 months, and mean body weight, 2.5-3.0 kg) were divided randomly into three groups with each group containing 8 rabbits. After clamping 10-15 cm segments of small bowel and their veins for 0.5 hours (Group A), 1-2 hours (Group B), and 3-5 hours (Group C), respectively, multi-phase spiral CT was performed at baseline, and at arterial, venous, and delayed phases after intravenous contrast administration. Then the rabbits were sacrificed to observe their surgical and histological changes. Two radiologists, blinded to the animal model classification and their histological results, individually reviewed the CT images to observe the CT appearances of the closed loop. Statistical significance criteria was determined by P 0.05) at baseline, however, they were significantly different (P<0.05) at all phases after enhancement. Among rabbits without necrotic closed loop, 11 of 13 had continuous enhancement at all phases, while only 1 of 11 rabbits with necrotic closed loop showed continuous enhancement (P<0.05). Conclusion: The ischemia of bowel wall in different phases after clamping small bowel and their veins can be evaluated by using enhanced multi-phase spiral CT. Continuous enhancement of bowel wall in multi-phase spiral CT can be seen prominently in the early bowel ischemia, but necrotic bowel shows no enhancement. (authors)

  7. Functional MRI in schizophrenia. Diagnostics and therapy monitoring of cognitive deficits of schizophrenic patients by functional MRI; Funktionelle MRT bei Schizophreniepatienten. Diagnostik und Therapiemonitoring kognitiver Defizite schizophrener Patienten mittels funktioneller MRT

    Energy Technology Data Exchange (ETDEWEB)

    Furtner, J.; Prayer, D. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria); Sachs, G. [Medizinische Universitaet Wien, Univ.-Klinik fuer Psychiatrie und Psychotherapie, Wien (Austria)

    2010-02-15

    Cognitive impairments are core psychopathological components of the symptomatic of schizophrenic patients. These dysfunctions are generally related to attention, executive functions and memory. This report provides information on the importance of using functional magnetic resonance imaging (fMRI) for the diagnostics and therapy monitoring of the different subtypes of cognitive dysfunctions. Furthermore, it describes the typical differences in the activation of individual brain regions between schizophrenic patients and healthy control persons. This information should be helpful in identifying the deficit profile of each patient and create an individual therapy plan. (orig.) [German] Kognitive Defizite sind ein zentraler Bestandteil der Symptomatik schizophrener Patienten. Diese Defizite betreffen v. a. die Aufmerksamkeit, exekutive Funktionen sowie das Gedaechtnis. Der vorliegende Beitrag zeigt den Stellenwert der funktionellen Magnetresonanztomographie (fMRT) in Hinblick auf Diagnostik und Therapiemonitoring der unterschiedlichen kognitiven Teilbereiche auf. Darueber hinaus werden die Unterschiede in Bezug auf die Aktivierung der einzelnen Gehirnareale zwischen schizophrenen Patienten und gesunden Kontrollpersonen dargestellt. Diese Informationen sollen helfen, in der Praxis ein Profil der kognitiven Leistungsreduktionen sowie ein darauf angepasstes Therapiekonzept zu erstellen. (orig.)

  8. Cardiac and vascular malformations; Fehlbildungen von Herz und Gefaessen

    Energy Technology Data Exchange (ETDEWEB)

    Ley, S. [Chirurgische Klinik Dr. Rinecker, Abteilung fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ley-Zaporozhan, J. [Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Abteilung Paediatrische Radiologie, Muenchen (Germany)

    2015-07-15

    Malformations of the heart and great vessels show a high degree of variation. There are numerous variants and defects with only few clinical manifestations and are only detected by chance, such as a persistent left superior vena cava or a partial anomalous pulmonary venous connection. Other cardiovascular malformations are manifested directly after birth and need prompt mostly surgical interventions. At this point in time echocardiography is the diagnostic modality of choice for morphological and functional characterization of malformations. Additional imaging using computed tomography (CT) or magnetic resonance imaging (MRI) is only required in a minority of cases. If so, the small anatomical structures, the physiological tachycardia and tachypnea are a challenge for imaging modalities and strategies. This review article presents the most frequent vascular, cardiac and complex cardiovascular malformations independent of the first line diagnostic imaging modality. (orig.) [German] Fehlbildungen von Herz und Gefaessen zeigen einen erheblichen Variationsspielraum. Es gibt zahlreiche Varianten und Defekte mit geringer Auspraegung, welche nur per Zufall im Lauf des Lebens detektiert werden; hierzu zaehlen z. B. die persistierende linke obere Hohlvene oder partielle Lungenvenenfehlmuendungen. Andere kardiovaskulaere Fehlbildungen zeigen sich frueh post partum und muessen zeitnah, meist operativ, versorgt werden. Zu diesem Zeitpunkt ist die Echokardiographie ein etabliertes und vollstaendig ausreichendes Verfahren zur morphologischen und funktionellen Charakterisierung. Nur in seltenen Faellen wird eine zusaetzliche Bildgebung mittels CT oder MRT benoetigt. Wenn ja, stellen die kleinen anatomischen Strukturen, die physiologische Tachykardie und Tachypnoe eine besondere Herausforderung fuer die Diagnostik dar. In dieser Uebersicht werden, unabhaengig vom diagnostischen Verfahren, die haeufigsten vaskulaeren, kardialen und komplexen kardiovaskulaeren Malformationen

  9. Design of wireless data transmission system for spiral CT

    International Nuclear Information System (INIS)

    Wang Jue; Wang Fuquan; Liu Huaili

    2010-01-01

    A new wireless data transmission scheme based on UWB was proposed after studying the structure and character of spiral CT transmission system, the system was designed and validated. Using UWB device as wireless module to realize wireless data transmission. Using FPGA as main controller to meet the requirement of timing control for system module. Using two pieces of SDRAM in pingpang operation to realize large capacity storage mechanism. Using USB 2.0 interface to realize high-speed connection with UWB module. The results show that the transmission speed of the system arrival at 16.87 M bit ps within 3 meters, and the precision is 100%, it can be used for line-array spiral CT. (authors)

  10. Modern diagnostics of cystic liver lesions and hemangiomas; Moderne Diagnostik zystischer Leberlaesionen und Haemangiome

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S.; Bastati-Huber, N.; Ba-Ssalamah, A. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Wien (Austria); Brancatelli, G. [Universitaetsklinikum Palermo, Abteilung Radiologie, Palermo (Italy)

    2015-01-01

    Cystic liver lesions incorporate a broad heterogeneous group of mostly benign but also malignant abnormalities. The radiological aim is the non-invasive diagnosis with the use of different imaging modalities to determine the type of lesion. The common generally asymptomatic incidental findings of cystic lesions on ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) must be classified on the basis of specific imaging features. Such a differentiation is essential because the clinical consequences and the appropriate therapy can vary depending on the underlying pathology. Due to the morphological overlap of many cystic lesions, conventional radiological methods are often insufficient. The huge advances in cross-sectional imaging (multidetector CT, MRI with special sequences and different contrast agents and MR cholangiopancreatography) in combination with the clinical history usually enable a non-invasive diagnosis. Pathognomonic morphological and hemodynamic lesion features, as well as a knowledge of the pathomechanisms, help to differentiate this broad spectrum of entities. In this article the different entities of cystic liver lesions, together with the appropriate diagnostic method for detection and distinction and including their strengths and limitations, are demonstrated. A well-founded knowledge about the development of various cystic liver lesions and the suitable choice of imaging method facilitate a non-invasive diagnosis. (orig.) [German] Die zystischen Leberlaesionen umfassen eine grosse heterogene Gruppe meist benigner, jedoch auch maligner Veraenderungen. Das radiologische Ziel ist die nichtinvasive Artdiagnose mithilfe verschiedener bildgebender Verfahren. Die haeufigen, meist asymptomatischen Zufallsbefunde in Ultraschall, CT und MRT muessen anhand spezieller bildgebender Kriterien klassifiziert werden. Eine Differenzierung ist hierbei essenziell, da die klinischen Konsequenzen und weiterfuehrenden Therapien je nach zugrunde

  11. Multiple myoma: current recommendations for imaging; Multiples Myelom: Aktuelle Empfehlungen fuer die Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hillengass, J. [Medizinische Universitaetsklinik, Abteilung fuer Haematologie, Onkologie und Rheumatologie, Heidelberg (Germany); Deutsches Krebsforschungszentrum, Abteilung Radiologie E010, Heidelberg (Germany); Delorme, S. [Deutsches Krebsforschungszentrum, Abteilung Radiologie E010, Heidelberg (Germany)

    2012-04-15

    zur Erfassung umschriebener Knochendestruktionen, von Osteoporose oder Frakturen. Die Ganzkoerper-low-dose-CT und Ganzkoerper-MRT ermoeglichen eine Darstellung sowohl des mineralisierten Knochens als auch des Knochenmarks mit einer hoeheren Sensitivitaet, hoeherem Patientenkomfort und im Falle der MRT ohne Strahlenbelastung. Nach den Ergebnissen der Literatur sind Schnittbildverfahren dem Roentgenskelettstatus signifikant ueberlegen, wobei die Ganzkoerper-MRT fuer den Nachweis insbesondere eines diffusen Knochenmarkbefalls signifikant besser ist als die Ganzkoerper-CT. Praktisch jeder osteodestruktive Herd ist in der MRT sichtbar. Allerdings ist fuer die Beurteilung der Osteodestruktion selbst wiederum eine CT erforderlich. Die Sensitivitaeten von PET/CT und MRT sind vergleichbar. Wie bereits in einigen Zentren insbesondere in Deutschland umgesetzt, sollten bei Verfuegbarkeit das Ganzkoerper-MRT und das Ganzkoerper-CT den konventionellen Roentgenskelettstatus ersetzen. Bei Erstdiagnose bzw. Verdacht auf eine monoklonale Gammopathie unklarer Signifikanz (MGUS), ''smoldering multiple myeloma'' und symptomatisches multiples Myelom sollten sowohl eine Ganzkoerper-MRT als auch eine Ganzkoerper-CT durchgefuehrt werden. Bei asymptomatischem Myelom oder MGUS waere die Ganzkoerper-MRT bis zur Detektion des ersten umschriebenen Myelomherdes ausreichend. Beim symptomatischen Myelom mit Knochenlaesionen sollten in der Regel die Ganzkoerper-CT und fuer spezielle Fragestellungen die MRT eingesetzt werden. (orig.)

  12. Focal lesions in whole-body MRI in multiple myeloma. Quantification of tumor mass and correlation with disease-related parameters and prognosis; Fokale Laesionen in der Ganzkoerper-MRT beim multiplen Myelom. Quantifizierung der Tumorlast und Korrelation mit krankheitstypischen Parametern und Prognose

    Energy Technology Data Exchange (ETDEWEB)

    Brandelik, S.C.; Kauczor, H.U. [Universitaetsklinikum Heidelberg, Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Krzykalla, J.; Hielscher, T. [Deutsches Krebsforschungszentrum (dkfz), Biostatistik, Heidelberg (Germany); Hillengass, J. [Universitaetsklinikum Heidelberg, Haematologie und Onkologie, Heidelberg (Germany); Kloth, J.K. [Radiologie Loebau, Loebau (Germany); Weber, M.A. [Universitaetsklinikum Heidelberg, Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsmedizin Rostock, Diagnostische und Interventionelle Radiologie, Rostock (Germany)

    2018-01-15

    In this study, we evaluated methods of quantification of tumor mass in whole-body MRI (wb-MRI) in multiple myeloma and correlated these with disease-related parameters in serum and bone marrow. We retrospectively evaluated wb-MRIs of 52 patients with focal infiltration pattern and a total of 700 focal lesions (subsequently called lesions). We determined the longest diameter (LD), the segmented volume (SV), and the morphology (spherical or non-spherical). We correlated total number/volume of the lesions with clinical parameters and prognosis and furthermore LD with SV. After that we analyzed the agreement of SV and estimated volume (EV) using the volume formula of a sphere based on LD. Results showed no significant correlations of total number/volume with prognosis or clinical parameters. The latter were situated predominantly in the normal range. Furthermore, 10% of lesions were spherical. SV and LD correlated significantly in single lesions and on patient level. SV was in lesions <6 cm{sup 3} systematically larger and in lesions ≥6 cm{sup 3} smaller than EV. In 95%, we found in small lesions a deviation of EV versus SV from +0.9 cm{sup 3} to -4.6 cm{sup 3} and in large lesions from +160 cm{sup 3} to -111 cm{sup 3} (EV-SV). Quantification of tumor mass in the focal infiltration pattern is performed more accurately by volumetry than LD due to the predominant existence of non-spherical lesions. The patient cohort with clinical parameters predominantly in the normal range is distributed to ISS stage I and partly pretreated, a fact that makes interpretation of absent correlations more difficult. Consider also a variation in activity of lesions and a diffuse infiltration not detectable by MRI. (orig.) [German] In dieser Studie wurden Methoden der Tumorlastquantifizierung in der Ganzkoerper-Magnetresonanztomographie (GK-MRT) beim Multiplen Myelom untersucht und mit krankheitstypischen Parametern in Serum und Knochenmark korreliert. Die GK-MRT von 52 Patienten mit

  13. Benign diseases of the mandible in MRI; Benigne Erkrankungen des Unterkiefers im MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kress, B.; Sartor, K. [Universitaetsklinikum Heidelberg (Germany). Abt. Neuroradiologie; Gottschalk, A. [Bundeswehrkrankenhaus, Ulm (Germany). Abt. fuer Radiologie; Schmitter, M. [Universitaetsklinikum Heidelberg (Germany). Abt. fuer Zahnaerztliche Prothetik

    2004-04-01

    Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und detailreich darstellen lassen. In der bildgebenden Diagnostik der Binnenstoerung des Kiefergelenks (internal derangement) gilt die MRT als Goldstandard. Die MR-Tomographie des Unterkiefers erfordert hochaufloesende Techniken und bei besonderen Indikationen die intravenoese Kontrastmittelgabe. Diese Techniken erlauben es, das neurovaskulaere Buendel des Unterkiefers darzustellen. In den letzten Jahren sind neue Indikationsgebiete hinzugekommen, darunter solche, die die Unversehrtheit des N.alveolaris inferior bei Frakturen oder Raumforderungen des Unterkiefers ueberpruefen. Neue quantitative Verfahren geben mittlerweile Einblicke in Pathophysiologie. Ziel dieser Uebersichtsarbeit soll es sein, klassische Indikationen der Unterkiefer-MRT darzustellen und innovative Anwendungsmoeglichkeiten aufzuzeigen. (orig.)

  14. Virtual gastroscopy using spiral CT in gastric lesions

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Kang, Heoung Keun; Jeong, Yong Yeon; Yoon, Man Won; Song, Sang Gook; Jeong, Gwang Woo

    1998-01-01

    To compare virtual gastroscopy using spiral CT with conventional endoscopy for the detection and evaluation of gastric lesions. During a previous six-month period, 30 patients with pathologically-proven gastric lesions underwent conventional endoscopy and virtual gastroscopy using spiral CT. There were 18 cases of advanced gastric carcinoma, eight benign ulcers, and four submucosal tumors(two leiomyomas, two lymphomas). Source images of virtual gastroscopy were three-dim-ensionally reconstructed within an Advantage Windows Workstation and virtual gastroscopic images were obtained using Navigator Software. On analysis, images were graded according to their quality(excellent, good, poor). Virtual gastroscopic images were interpreted by two radiologists blinded to conventional endoscopic findings, and were subsequently compared with endoscopic findings in terms of detectability and findings. In the cases of advanced gastric carcinoma, lesions were classified according to Borrmann's system. For virtual gastroscopy, overall image quality was excellent in 21 cases(70%), good in five(17%), and poor in four(13%). Lesions were detected in 25 cases(83%). Among the 18 advanced gastric carcinomas, virtual gastroscopy image quality was excellent in 14 cases(78%), good in two(11%), and poor in two(11%). Lesions were detected in 16 cases(89%). Two Borrmann type IV cases were not detected. Among the eight benign ulcers, virtual gastroscopy image quality was excellent in three cases(38%), good in three(38%), and poor in two(25%). The detection of lesion was possible in five cases(63%). In all submucosal tumors, virtual gastroscopy image quality was excellent. Lesions were detected in all cases. Virtual gastroscopy using spiral CT is safe and noninvasive, and for the evaluation of gastric lesions may be complementary to axial CT. It successfully detects gastric lesions, and in depicting the pattern of gastric folds its image quality is excellent.=20

  15. The value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Huang Zhi; Liu Zhang; Yang Chaoxiang; Lin Chengye; Zhang Li; Li Yuxiang; Ma Yunyan; Xiao Haisong; Lu Zhifeng; Wang Bo; Zhou Yunhong

    2009-01-01

    Objective: To approach the value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice in order to improve the correctness of the diagnosis. Methods: Analysis the cases' clinical manifestation and the CT images, who were diagnosed as obstructive jaundice by operation. All of cases had high-resolution computed tomograyhy scan. The thickness and the interval is 5mm, reconstructed the thickness and the interval to 1 mm and 1.5 mm, then send the images to the workstation and MRR were processed. Analysis the date with the pathology. Results: Spiral CT thin imaging reconstruction have 98% and 93% in the accuracy of location and characterization in the obstruction. Conclusion: The spiral CT thin imaging reconstruction is a good method to improve the accuracy of location and characterization in the obstructive jaundice. (authors)

  16. The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences. Diagnostik entzuendlicher Muskel- und Gefaesserkrankungen in der MRT mit STIR-Sequenzen

    Energy Technology Data Exchange (ETDEWEB)

    Beese, M.S. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Winkler, G. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany) Neurologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Nicolas, V. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Maas, R. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Kress, D. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Kunze, K. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany) Neurologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)); Buecheler, E. (Radiologische Klinik, Universitaetskrankenhaus Eppendorf, Hamburg (Germany))

    1993-06-01

    The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T[sub 1] and T[sub 2] weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in whom the suspected diagnosis could not be confirmed there was muscle oedema in 11 cases (9 neuropathies out of 22, two myopathies out of 10). Oedema indicated inflammatory muscular or vascular disease with a sensitivity of 97% (except in treated patients and for focal myositis). The number of false negative biopsies can be greatly reduced by the use of MRT. (orig.)

  17. Three-dimensional spiral CT of craniofacial malformations in children

    International Nuclear Information System (INIS)

    Binaghi, S.; Gudinchet, F.

    2000-01-01

    Objective. To assess the value of three-dimensional CT (3D CT) in the diagnosis and management of suspected paediatric craniofacial malformations. Materials and methods. Twenty-eight children (12 girls, 16 boys) with a mean age of 4 years, suffering from craniofacial or cervical malformations, underwent craniofacial spiral CT. 3D reformatting was performed using an independent workstation. Results. 3D CT allowed the preoperative evaluation of 16 patients with craniosynostosis and the post-surgical management of 2 patients. 3D CT clearly depicted malformations of the skull base involving the petrous bone in seven patients (four cases of Goldenhar-Gorlin syndrome, one case of Treacher-Collins syndrome and two cases of Crouzon's disease). Four patients with craniofacial clefts were also evaluated. Radiological findings were confirmed by the clinical and intraoperative findings in all patients that underwent surgical treatment. Movement artefacts and ''Lego effect'' related to abrupt change of cranial vault border were encountered and are discussed. Conclusions. 3D CT of the skull can safely and reliably identify paediatric craniofacial malformations involving bone, and it should be used as morphological mapping to help the surgeon in planning surgical treatment. (orig.)

  18. Functional MRI 2.0. {sup 23}Na and CEST imaging; Funktionelle MRT 2.0. {sup 23}Na- und CEST-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Haneder, S. [Uniklinik Koeln, Institut fuer Diagnostische und Interventionelle Radiologie, Koeln (Germany); Konstandin, S. [Universitaet Bremen, MR-Bildgebung und -Spektroskopie, Fachbereich 1 (Physik/Elektrotechnik), Bremen (Germany); Fraunhofer MEVIS, Institut fuer Bildgestuetzte Medizin, Bremen (Germany)

    2016-02-15

    gewinnen. In diesem Uebersichtsartikel werden 2 MR-Techniken vorgestellt, welche physiologische Prozesse im menschlichen Koerper erfassen koennen. Im Gegensatz zu allen anderen funktionellen MR-Methoden, welche Wasserstoffprotonen fuer die Bildgebung verwenden, nutzt die erste vorgestellte Technik den Spin anderer Kerne fuer die Bildgebung und ermoeglicht hierdurch eine gaenzlich differente Einsicht in den menschlichen Koerper. Der Fokus dieses Artikels liegt hierbei auf der {sup 23}Na-MRT, da sie aufgrund der MR-guenstigen Eigenschaften des Natriumkerns momentan den Schwerpunkt der Forschung im Bereich der sogenannten X-Kern-Bildgebung darstellt. Bei der zweiten Technik handelt es sich um ein relativ neuartiges MR-Verfahren, die Chemical-exchange-saturation-transfer(CEST)-Bildgebung, welche Austauschprozesse zwischen Protonen in Metaboliten und Protonen in freiem Wasser detektieren kann. Im ersten Teil dieses Artikels werden die technischen Grundlagen, Probleme, Vor- und Nachteile und im zweiten Teil die potenziellen klinischen Anwendungen dieser Techniken beleuchtet. Anwendungsbeispiele kommen aus dem Gebiet der zerebralen Bildgebung (z. B. Schlaganfall, Tumoren), der muskuloskelettalen Bildgebung (z. B. Arthrose, degenerative Prozesse) und der abdominellen Bildgebung (z. B. Niere, Hypertension). Beide Techniken bieten ein unglaubliches Potenzial fuer die Zukunft, stehen aber bislang noch an der Schwelle zum klinischen Einsatz und werden aktuell nur in ausgewaehlten universitaeren Zentren evaluiert. (orig.)

  19. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  20. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes.

  1. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    International Nuclear Information System (INIS)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes

  2. Evaluation of percutaneous vertebroplasty in osteoporotic vertebral fractures using a combination of CT fluoroscopy and conventional lateral fluoroscopy; Perkutane Vertebroplastie osteoporosebedingter Wirbelkoerperfrakturen: Erfahrungen mit der CT-Fluoroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Pitton, M.B.; Schneider, J.; Brecher, B.; Herber, S.; Mohr, W.; Thelen, M. [Klinik fuer Radiologie, Universitaetskliniken Mainz (Germany); Drees, P.; Eckardt, A.; Heine, J. [Klinik fuer Orthopaedie, Universitaetskliniken Mainz (Germany)

    2004-07-01

    cannulation of the vertebra had been changed before cement application resulting in a hole in the dorsolateral vertebral wall. However, all patients were discharged without evidence of neurologic complications. Multiplanar reconstructions of CT scans were used for the detection of extraosseous cement leaks: The incidence of extraosseous cement leaks was 4.1% in epidural veins, 6.5% in paravertebral vessels (6 veins, 2 arteries), and 17.9 and 11.4% respectively, for upper or lower and plates. At discharge, 25 patients (43.1%) were free of pain and 28 (48,3%) significantly improved with a considerable reduction of analgetic drugs. Significant complaints persisted in 5 patients (8.6%) with concomitant degenerative disease in four and vasculitis in one case. (orig.) [German] Zielsetzung: Klinisch-radiologische Pruefung der Vertebroplastie mittels CT-Fluoroskopie und seitlicher Durchleuchtung bei Patienten mit osteoporosebedingten Wirbelkoerperfrakturen. Material und Methoden: 58 Patienten (23 Maenner und 35 Frauen, Alter 69,7 {+-} 10,2 Jahre) mit schmerzhaften, osteoporosebedingten Wirbelkoerperfrakturen wurden mittels Vertebroplastie behandelt. Praeinterventionell erfolgte eine Spiral-CT mit sagittaler Rekonstruktion zur Befunddokumentation. Die Eingriffe erfolgten in Analgosedierung. Die Platzierung der Vertebroplastiekanuele und die Applikation des Knochenzementes erfolgten unter CT-Fluoroskopie und seitlicher Durchleuchtung. Bei unguenstiger Zementausbreitung wurde die Applikation fuer 30-60 s unterbrochen. Nach Polymerisation des Zementes an dieser Lokalisation wurde die Injektion bis zur ausreichenden Wirbelkoerperfuellung fortgesetzt. Das Ergebnis wurde mittels Spiral-CT mit sagittaler Rekonstruktion des behandelten Wirbelsaeulenabschnittes dokumentiert. Ergebnisse: Insgesamt wurden 123 Wirbelkoerper behandelt, 39 Brustwirbel- und 84 Lendenwirbelkoerper. Alle Eingriffe konnten in Analgosedierung und Lokalanaesthesie durchgefuehrt werden. Im Mittel wurden 2,1 {+-} 1,3 (1

  3. Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering; Die computerassistierte Operationsplanung in der Abdominalchirurgie des Kindes. 3D-Visualisierung mittels ''volume rendering'' in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, P.; Holland-Cunz, S.; Waag, K.L. [Universitaetsklinikum Heidelberg (Germany). Kinderchirurgie; Troeger, J. [Universitaetsklinikum Heidelberg, (Germany). Paediatrische Radiologie; Schenk, J.P. [Universitaetsklinikum Heidelberg, (Germany). Paediatrische Radiologie; Universitaetsklinikum, Paediatrische Radiologie, Heidelberg (Germany)

    2006-08-15

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this. A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning. (orig.) [German] Komplexe Operationen bei ausgepraegten pathologischen Veraenderungen anatomischer Strukturen des kindlichen Abdomens benoetigen eine exakte Operationsvorbereitung. 3D-Visualisierung und computerassistierte Operationsplanung anhand von CT-Daten finden fuer schwierige chirurgische Eingriffe bei Erwachsenen in zunehmendem Masse Anwendung. Aus strahlenhygienischen Gruenden und bei besserer Weichteildifferenzierung ist jedoch neben der Sonographie die Magnetresonanztomographie (MRT) bei Kindern das Diagnostikum der Wahl. Die 3D-Visualisierung dieser MRT-Daten ist dabei jedoch aufgrund vielfaeltiger Schwierigkeiten bisher nicht durchgefuehrt worden, obwohl sich das Gebiet embryonaler Fehlbildungen und Tumoren geradezu anbietet. Vorgestellt wird eine weiterentwickelte und an die Fragestellungen der abdominellen Kinderchirurgie angepasste, sehr leistungsstarke raycastingbasierte 3D-volume-rendering-Software (VG Studio Max 1

  4. SPECT/CT for staging and treatment monitoring in oncology. Applications in differentiated thyroid cancer and liver tumors; SPECT/CT zum initialen Staging und Therapiemonitoring in der Onkologie. Indikationen beim differenzierten Schilddruesenkarzinom und bei Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Weber, K.; Berger, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Mustafa, M.; Bartenstein, P.; Haug, A. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2012-07-15

    and SPECT/CT provides more accurate imaging of the arterial supply of the liver and of potential outflows of micro-spheres into other organs. SPECT/CT allows evaluation and quantification of the uptake of liver tumors. Improved postablative staging in patients with differentiated thyroid cancer by SPECT/CT in comparison to radioiodine whole body scans can be achieved. Improved planning and monitoring of SIRT therapies utilizing SPECT/CT leads to optimized therapeutic doses within liver lesions. Integration of SPECT/CT into the clinical standard for postablative staging in patients with DTC is recommended as well as utilization of SPECT/CT during the planning process, for dose calculation and treatment monitoring of SIRT therapies. (orig.) [German] In den letzten Jahren hat die Hybridbildgebung mit Verbindung von funktioneller und morphologischer Information zur Diagnostik zahlreicher Erkrankungen zunehmend an Bedeutung gewonnen. Bei Patienten mit differenziertem Schilddruesenkarzinom (DTC) wird nach erfolgter Radiojodtherapie (RJT) ein planares Ganzkoerperszintigramm zum Staging durchgefuehrt. Die diagnostische Genauigkeit dieser szintigraphischen Methode ist jedoch aufgrund limitierter raeumlicher Aufloesung begrenzt. Die Radioembolisation von mit {sup 90}Yttrium beladenen Mikrosphaeren (selektive interne Radiotherapie, SIRT) ermoeglicht eine wenig invasive Therapie primaerer und sekundaerer Lebertumoren. Zur Vermeidung von Nebenwirkungen der Mikrosphaeren durch einen Abstrom in Darm, Magen und Lunge muss vor Therapiebeginn eine Darstellung des durch die leberversorgenden Arterien versorgten Gebiets mittels {sup 99m}Tc-MAA ({sup 99m}Technetium-makroaggregiertes Albumin) und einer Szintigraphie erfolgen. Auch hier limitiert die begrenzte morphologische Information der Szintigraphie das Therapiemonitoring. {sup 131}Jod-Ganzkoerperszintigramm zum Nachweis einer erfolgreichen Ablation und Staging ca. 3-4 Tage postablativ bei Patienten mit DTC. Ueberwachung des

  5. Urämische Kardiomyopathie und der Einfluss der Hämodialyse

    OpenAIRE

    Valina, Ulrike Katrin

    2011-01-01

    ZIEL: Analyse von Risikofaktoren und Entstehungsmechanismen der urämischen Kardiomyopathie bei Hämodialysepatienten und Vergleich von Diagnostiken zur frühen Detektion kardialer Funktionstörungen zur Optimierung der Therapie bei terminaler Niereninsuffizienz und Senkung der hohen Mortalitätsrate. METHODEN: Einschluss von 32 Hämodialysepatienten. Messungen mittels Blutentnahme (Entzündungs-, Atherosklerose-, Anämieparameter, EPO, PTH und RAAS) und MRT (Herzfunktion, Herzmorphologie und Her...

  6. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  7. Functioning islet cell tumor of the pancreas. Localization with dynamic spiral CT

    International Nuclear Information System (INIS)

    Chung, M.J.; Choi, B.I.; Han, J.K.; Chung, J.W.; Han, M.C.; Bae, S.H.

    1997-01-01

    Purpose: The purpose of this study was to evaluate the usefulness of dynamic spiral CT, including multidimensional reformation, in the detection and localization of islet cell tumors of the pancreas. Material and Methods: Seven patients with histopathologically proven functioning islet cell tumors of the pancreas were studied with 2-phase contrast-enhanced spiral CT. Scanning of the arterial phase and late phase was started 30 s and 180 s, respectively, after injection of 100 ml of contrast medium at a rate of 3 ml/s. Results: Axial images in the arterial phase depicted the lesions in 5 patients, but in the late phase in only one patient. Multiplanar reformatted images of the arterial phase depicted the lesions in all 7 patients. Maximal intensity projection images demonstrated all lesions with information of their relationship to the vascular structure. Conclusion: Dynamic spiral CT with scanning during the arterial phase and retrospective multidimensional reformation is useful for preoperative detection and localization of small islet cell tumors of the pancreas. (orig.)

  8. Simultaneous whole-body PET-MRI in pediatric oncology. More than just reducing radiation?; Simultane Ganzkoerper-PET-MRT in der paediatrischen Onkologie. Mehr als nur Strahlenersparnis

    Energy Technology Data Exchange (ETDEWEB)

    Gatidis, S.; Gueckel, B.; Schaefer, J.F. [Universitaet Tuebingen, Radiologische Klinik, Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Fougere, C. la [Universitaet Tuebingen, Radiologische Klinik, Nuklearmedizin, Tuebingen (Germany); Schmitt, J. [Universitaet Tuebingen, Abteilung fuer Praeklinische Bildgebung und Radiopharmazie, Werner Siemens Imaging Center, Tuebingen (Germany)

    2016-07-15

    Diagnostic imaging plays an essential role in pediatric oncology with regard to diagnosis, therapy-planning, and the follow-up of solid tumors. The current imaging standard in pediatric oncology includes a variety of radiological and nuclear medicine imaging modalities depending on the specific tumor entity. The introduction of combined simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) has opened up new diagnostic options in pediatric oncology. This novel modality combines the excellent anatomical accuracy of MRI with the metabolic information of PET. In initial clinical studies, the technical feasibility and possible diagnostic advantages of combined PET-MRI have been in comparison with alternative imaging techniques. It was shown that a reduction in radiation exposure of up to 70 % is achievable compared with PET-CT. Furthermore, it has been shown that the number of imaging studies necessary can be markedly reduced using combined PET-MRI. Owing to its limited availability, combined PET-MRI is currently not used as a routine procedure. However, this new modality has the potential to become the imaging reference standard in pediatric oncology in the future. This review article summarizes the central aspects of pediatric oncological PET-MRI based on existing literature. Typical pediatric oncological PET-MRI cases are also presented. (orig.) [German] Die bildgebende Diagnostik spielt in der paediatrischen Onkologie eine zentrale Rolle fuer die Diagnose, die Therapieplanung und die Nachsorge solider Tumoren. Der aktuell bildgebende Standard in der paediatrischen Onkologie sieht - abhaengig von der vorliegenden Tumorentitaet - eine Kombination mehrerer radiologischer und nuklearmedizinischer Verfahren vor. Die Einfuehrung der simultanen Positronenemissionstomographie(PET)-Magnetresonanztomographie (MRT) hat neuartige Moeglichkeiten der Diagnostik in der paediatrischen Onkologie eroeffnet. Dabei kombiniert dieses neue Verfahren die

  9. MRI for therapy control in patients with aortic isthmus stenosis; MRT zur Therapiekontrolle bei Patienten mit Aortenisthmusstenose

    Energy Technology Data Exchange (ETDEWEB)

    Wintersperger, B.J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Toronto General Hospital, University of Toronto, Department of Medical Imaging, University Health Network, Toronto M5G 2N2 (Canada); Theisen, D.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2011-01-15

    Aortic isthmus stenosis is the most common congenital aortic anomaly and is often a problem for therapy surveillance. In addition to possible comorbidities (e.g. bicuspid aortic valve) it is accompanied by various middle and long-term complications depending on the primary choice of the therapeutic procedure. Magnetic resonance imaging (MRI) plays an important role for the mostly young patients in the control of the aortic isthmus stenosis and therapy because it is non-invasive and there is no X-ray exposure. Radiologists should be well-informed on the principles of the therapeutic procedure in order to be competent in the interpretation of MRI findings. Due to the continuous development of MRI technology, techniques for functional evaluation (e.g. dynamic MRA, 4D PC flow measurement) are increasingly becoming available in addition to high-resolution MR angiography (MRA), which could predict the risk of possible complications, such as aneurysms. However, in this aspect further studies are necessary. Interventional therapy with stents and stent grafts is often employed for the therapy of possible complications following an operation (aneurysms, restenosis) but because of massive metal artefacts the use of MRI is often sometimes severely limited. (orig.) [German] Die Aortenisthmusstenose als haeufigste angeborene Aortenanomalie stellt ein haeufiges Problem der Therapieueberwachung dar und ist neben moeglichen begleitenden Anomalien (z. B. bikuspidale Aortenklappe) in Abhaengigkeit vom primaer gewaehlten Therapieverfahren mit verschiedenen Komplikationen im mittel- bis laengerfristigem Verlauf vergesellschaftet. Bei der Kontrolle der Aortenisthmusstenose bzw. deren Therapie spielt die Magnetresonanztomographie (MRT) aufgrund der Nichtinvasivitaet und fehlenden Strahlenexposition bei den meist juengeren Patienten eine wichtige Rolle. Der Radiologe sollte ueber die Grundzuege der Therapieverfahren informiert sein, um die MRT-Befunde kompetent zu befunden. Durch stetige

  10. Eagle Syndrome: diagnostic imaging and therapy; Eagle Syndrom - Bildgebende Diagnostik und Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, J.; Andresen, R. [Abt. fuer Bildgebende Diagnostik und Interventionelle Radiologie, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany); Sonnenburg, M. [Fachbelegarztpraxis fuer Mund, Kiefer, Gesichtschirurgie und Plastische Operationen, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany); Scheufler, O. [Klinik fuer Plastische, Wiederherstellungs- und Handchirurgie, Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe Univ. Frankfurt am Main (Germany)

    2004-07-01

    In the case of clinical symptoms such as dysphagia, foreign-body sensation and chronic neck or facial pain close to the ear, an Eagle syndrome should be considered in the differential diagnosis. Rational diagnostics and therapy are elucidated on the basis of four case reports. Four patients presented in the out-patients clinic with chronic complaints on chewing and a foreign-body sensation in the tonsil region. Upon specific palpation below the mandibular angle, pain radiating into the ear region intensified. In all patients, local anaesthesia with lidocaine only led to a temporary remission of symptoms. Imaging diagnostics then performed initially included cranial survey radiograms according to Clementschitsch as well as in the lateral ray path and an OPTG. An axial spiral-CT was then performed using the thin-layer technique with subsequent 3-D reconstruction. Therapy consisted of elective resection with a lateral external incision from the retromandibular. From a symptomatic point of view, the cranial survey radiograms and the OPTG revealed hypertrophic styloid processes. The geometrically corrected addition of the axial CT images produced an absolute length of 51-58 mm. The 3-D reconstruction made it possible to visualise the exact spatial orientation of the styloid processes. An ossification of the stylohyoid ligament could definitely be ruled out on the basis of the imaging procedures. After resection of the megastyloid, the patients were completely free of symptoms. Spiral-CT with subsequent 3-D reconstruction is the method of choice for exact determination of the localisation and size of a megastyloid, while cranial survey radiograms according to Clementschitsch and in the lateral ray path or an OPTG can provide initial information. The therapy of choice is considered to be resection of the megastyloid, whereby an external lateral incision has proved effective. (orig.) [German] Bei klinischen Beschwerden wie Dysphagie, Fremdkoerpergefuehl und chronischen

  11. Quantitative evaluation in enhancement of pancreas and adjacent vessels during spiral CT

    International Nuclear Information System (INIS)

    Kim, Hyoung Seuk; Shin, Kue Hee; Park, Cheol Min; Cha, Sang Hoon; Chung, Kyoo Byung

    1997-01-01

    To determine by quantitative evaluation of pancreatic and adjacent vascular enhancement during spiral CT, the ideal scan delay for examination of the pancreas. Dual(n=3D90) and triple(n=3D90) phase spiral CT scans of patients whose pancreas showed no pathologic condition were retrospectively evaluated. Dual-phase scans were performed at 43 seconds(early), and 5-6 minutes(delayed) after the injection of 120ml of contrast material at an injection rate of 3ml/sec;triple-phase scans were performed at 25 seconds(arterial),60-65 seconds (portal) and 5-6 minutes (delayed) after the injection of 120-140ml of contrast material at an injection rate of 2-4ml/sec, and ten patients also underwent precontrast scanning. CT attenuation values(HU) were measured in the head, body and tail of the pancreas, aorta, and main portal vein during each phase of all scans. Triple-phase protocol was used to measure the effect of different total volumes and injection rates on enhancement of the pancreas and adjacent vessels. There was no significant difference in the degree of enhancement of the pancreas head, body and tail during each phase(p>0.05). The pancreas was maximally enhanced on 43 second delayed scan(132±20HU)(p 0.05). The main portal vein showed maximum enhancement on 43-second delayed scan(207±44HU)(p<0.05). Different total volume of contrast material did not change the enhancement of the pancreas and adjacent vessels. At an injection rate of 2ml/sec, peak enhancement of the pancreas, aorta and portal vein was obtained on 60-65 second delayed scan, and at 4ml/sec, peak enhancement was obtained on 25 second delayed scan(p<0.05). Observing the usual protocols for abdominal spiral CT scanning, the pancreas was most effectively evaluated using a 43-second delayed scan. An increased injection rate resulted in earlier enhancement of the pancreas, aorta and portal vein

  12. Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose

    Energy Technology Data Exchange (ETDEWEB)

    Venz, S. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Sander, B. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Benndorf, G. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Terstegge, K. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Podrabsky, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Cordes, M. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1994-12-31

    We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis beobachtet. Eine Neuritis der Hirnnerven war nur mit der MRT nachweisbar. Die kontrastmittelunterstuetzte MRT sollte in der bildgebenden Diagnostik einer intrakraniellen Turberkulose primaer zum Einsatz gelangen. (orig.)

  13. Magnetic resonance imaging of dilated cardiomyopathy; MRT bei dilatativen Kardiomyopathien

    Energy Technology Data Exchange (ETDEWEB)

    D' Anastasi, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Greif, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Medizinische Klinik und Poliklinik I, Muenchen (Germany); Reiser, M.F.; Theisen, D. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Deutsches Zentrum fuer Herzkreislaufforschung (DZHK), Muenchen (Germany)

    2013-01-15

    Dilated cardiomyopathy (DCM) is the most common type of cardiomyopathy with a prevalence of 1 out of 2,500 in adults. Due to mild clinical symptoms in the early phase of the disease, the true prevalence is probably even much higher. Patients present with variable clinical symptoms ranging from mild systolic impairment of left ventricular function to congestive heart failure. Even sudden cardiac death may be the first clinical symptom of DCM. The severity of the disease is defined by the degree of impairment of global left ventricular function. Arrhythmias, such as ventricular or supraventricular tachycardia, atrioventricular (AV) block, ventricular extrasystole and atrial fibrillation are common cardiac manifestations of DCM. Magnetic resonance imaging (MRI) plays an important role in the exact quantification of functional impairment of both ventricles and in the evaluation of regional wall motion abnormalities. With its excellent ability for the assessment of myocardial structure, it is becoming increasingly more important for risk stratification and therapy guidance. (orig.) [German] Die dilatative Kardiomyopathie (DCM) ist die haeufigste Form der Kardiomyopathie mit einer Praevalenz von 1/2500 Erwachsenen. Aufgrund der zunaechst milden klinischen Symptomatik ist jedoch von einer relativ hohen Dunkelziffer auszugehen. Die klinische Praesentation ist variabel, die Schwere der Erkrankung wird vom Ausmass der systolischen Funktionseinschraenkung bestimmt. Herzrhythmusstoerungen, wie ventrikulaere oder supraventrikulaere Tachykardien, AV-Blockierungen, ventrikulaere Extrasystolen und Vorhofflimmern sind moegliche klinische Manifestationen. Bei manchen Patienten ist der ploetzliche Herztod die erste klinische Manifestation der Erkrankung. Die kardiale MRT spielt eine bedeutende Rolle fuer die Beurteilung des Ausmasses der ventrikulaeren Dilatation, Dysfunktion und fuer die Beurteilung regionaler Wandbewegungsstoerungen. Darueber hinaus kann sie zur Anwendung kommen

  14. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  15. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  16. Magnetic resonance tomography (MRT) of the knee joint: Meniscus, cruciate ligaments and hyaline cartilage. Magnetresonanztomographie (MRT) des Kniegelenks: Meniskus, Kreuzbaender und hyaliner Gelenkknorpel

    Energy Technology Data Exchange (ETDEWEB)

    Hodler, J. (Radiologie, Universitaetsspital, Zurich (Switzerland) Orthopaedische Universitaetsklinik Balgrist, Zurich (Switzerland). Radiologische Abt.); Buess, E. (Orthopaedische Universitaetsklinik Balgrist, Zurich (Switzerland)); Rodriguez, M. (Orthopaedische Universitaetsklinik Balgrist, Zurich (Switzerland)); Imhoff, A. (Orthopaedische Universitaetsklinik Balgrist, Zurich (Switzerland))

    1993-08-01

    The use of MRT for diagnosing injury to the meniscus, the cruciate ligaments and hyaline cartilage was evaluated retrospectively in 82 knee joints without any knowledge of operative findings. In 49 cases the results were verified by arthroscopy and in 33 cases by arthrotomy. Sensitivity, specificity and diagnostic accuracy of MRT for meniscus lesions was 73.9%, 96.9%, and 94.6%. Corresponding values for lesions of the anterior cruciate ligament were 88.9%, 96.6%, and 94.7%, and for lesions of the hyaline cartilage 62.6%, 96.1%, and 87.9%, respectively. In addition to its high specificity, MRT proved accurate in excluding lesions of the meniscus (97.1%) of the anterior cruciate ligament (96.6%) and of hyaline cartilage (88.8%). A negative finding on MRT therefore makes the presence of a lesion of the meniscus, cruciate ligaments of cartilage unlikely. In such cases one is justified in delaying the use of arthroscopy or arthrotomy. (orig.)

  17. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  18. Working memory in volunteers and schizophrenics using BOLD fMRI; Das Arbeitsgedaechtnis bei Gesunden und bei Schizophrenen: Untersuchungen mit BOLD-fMRT

    Energy Technology Data Exchange (ETDEWEB)

    Giesel, F.L. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany); Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Hohmann, N. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany); Psychiatrische Universitaetsklinik Heidelberg, Sektion Gerontopsychiatrie (Germany); Seidl, U.; Kress, K.R.; Schoenknecht, P.; Schroeder, J. [Psychiatrische Universitaetsklinik Heidelberg, Sektion Gerontopsychiatrie (Germany); Kauczor, H.-U.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany)

    2005-02-01

    Functional magnetic resonance imaging uses the blood oxygen level-dependent effect (BOLD MRI) for noninvasive display of cerebral correlatives of cognitive function. The importance for the understanding of physiological and pathological processes is demonstrated by investigations of working memory in schizophrenics and healthy controls. Working memory is involved in processing rather than storage of information and therefore is linked to complex processes such as learning and problem solving. In schizophrenic psychosis, these functions are clearly restricted. Training effects in the working memory task follow an inverse U-shape function, suggesting that cerebral activation reaches a peak before economics of the brain find a more efficient method and activation decreases. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) nutzt den ''blood oxygen level dependent effect'' (BOLD-Effekt) zur nichtinvasiven Darstellung zerebraler Korrelate kognitiver Funktionen. Die Bedeutung dieses Verfahrens fuer das Verstaendnis physiologischer und pathologischer Prozesse wird anhand von Untersuchungen zum Arbeitsgedaechtnis bei Schizophrenen und gesunden Kontrollpersonen verdeutlicht. Das Arbeitsgedaechtnis dient weniger der Speicherung, sondern vielmehr der Verarbeitung von Informationen und ist deshalb in komplexe Prozesse wie Lernen und Problemloesen eingebunden. Im Rahmen schizophrener Psychosen kommt es zu einer deutlichen Einschraenkung dieser Funktionen. Erwartungsgemaess zeigen sich unter Durchfuehrung eines Arbeitsgedaechtnisparadigmas Unterschiede in der zerebralen Aktivitaet, die jedoch bei den Erkrankten unter Therapie prinzipiell reversibel sind. Von Interesse sind auch Trainingseffekte bei Gesunden, wobei eine verminderte Aktivierung nach Training auf eine ''Oekonomisierung'' schliessen laesst. (orig.)

  19. Magnetic resonance tomography in eclampsia; Magetresonanztomographie bei Eklampsie

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, U. [St.-Vincentius-Krankenhaeuser, Karlsruhe (Germany). Radiologische Klinik

    1995-05-01

    Eclampsia is a rare but severe complication during the course of a pregnancy. The CT-findings at the brain are well known. Reports on MRT-findings are limited, however, especially in German literature. We describe the MRT picture of the cerebral changes caused by eclampsia and discuss the advantages of MRT in comparison with CT. The use of contrast agents with MRT shows breakdown of blood-brain barrier but does not provide any information of therapeutical consequences and should be avoided during pregnancy. An early and targeted use of MRT in any case of unclear or suspicious neurological symptoms during pregnancy is recommended. MRT supports differential diagnosis regarding non pregnancy-related cerebral disease and can be helpful for therapy planning in cases of preeclampsia. Additionally, MRT offers the possibility to control the effect of therapy with regard to brain damage. (orig.) [Deutsch] Die Eklampsie ist eine seltene aber erhebliche Komplikation im Verlauf einer Schwangerschaft. Die computertomographischen Veraenderungen im Gehirn sind bekannt. Mitteilungen von kernspintomographischen Befunden finden sich vor allem in der deutschen Literatur noch selten. Wir beschreiben das kernspintomographische Bild der zerebralen Veraenderungen bei Eklampsie und diskutieren die Vorteile der MRT im Vergleich zur CT. Die Gabe von Kontrastmittel bei der MRT weist zwar die Blut-Hirn-Schrankenstoerung nach, bringt aber keine therapeutisch relevanten Informationen. Sie sollte waehrend der Schwangerschaft vermieden werden. Ein frueher und gezielter Einsatz der MRT bei unklaren oder verdaechtigen neurologischen Symptomen waehrend der Schwangerschaft ist sinnvoll. Die MRT unterstuetzt die Differentialdiagnose in bezug auf nicht schwangerschaftsbezogene zerebrale Leiden und kann fuer die Therapie richtungweisend sein, wenn die Gestose noch nicht ausgepraegt ist. (orig.)

  20. Measurement error of spiral CT volumetry: influence of low dose CT technique

    International Nuclear Information System (INIS)

    Chung, Myung Jin; Cho, Jae Min; Lee, Tae Gyu; Cho, Sung Bum; Kim, Seog Joon; Baik, Sang Hyun

    2004-01-01

    To examine the possible measurement errors of lung nodule volumetry at the various scan parameters by using a small nodule phantom. We obtained images of a nodule phantom using a spiral CT scanner. The nodule phantom was made of paraffin and urethane and its real volume was known. For the CT scanning experiments, we used three different values for both the pitch of the table feed, i.e. 1:1, 1:15 and 1:2, and the tube current, i.e. 40 mA, 80 mA and 120 mA. All of the images acquired through CT scanning were reconstructed three dimensionally and measured with volumetry software. We tested the correlation between the true volume and the measured volume for each set of parameters using linear regression analysis. For the pitches of table feed of 1:1, 1:1.5 and 1:2, the mean relative errors were 23.3%, 22.8% and 22.6%, respectively. There were perfect correlations among the three sets of measurements (Pearson's coefficient = 1.000, p< 0.001). For the tube currents of 40 mA, 80 mA and 120 mA, the mean relative errors were 22.6%, 22.6% and 22.9%, respectively. There were perfect correlations among them (Pearson's coefficient=1.000, p<0.001). In the measurement of the volume of the lung nodule using spiral CT, the measurement error was not increased in spite of the tube current being decreased or the pitch of table feed being increased

  1. The role of positron-emission-tomography (F-18-FDG-PET) in the staging and follow-up of lung cancer and in the evaluation of focal pulmonary abnormalities; Positronenemissionstomographie (PET) mit F-18-FDG in der Diagnostik des Bronchialkarzinoms und zur Dignitaetsabklaerung von pulmonalen Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R.P. [Zentralklinik Bad Berka (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Bonnet, R.B. [Zentralklinik Bad Berka (Germany). Klinik fuer Pneumologie; Presselt, N. [Zentralklinik Bad Berka (Germany). Klinik fuer Thorax- und Gefaesschirurgie; Leonhardi, J. [Zentralklinik Bad Berka (Germany). Inst. fuer Bildgebende Diagnostik

    2001-04-01

    bronchial carcinomas (except for slowly growing neuroendocrine tumors like carcinoids which show rarely an increased FDG metabolism). The specificity of FDG-PET is in the range of >80%. (orig.) [German] Prospektive Studien zeigten im Direktvergleich von PET und Spiral-CT eine deutlich hoehere diagnostische Genauigkeit der PET im Lymphknotenstaging des Bronchialkarzinoms (insbesondere mediastinal, d.h. N2- oder N3-Befall). Mittels FDG-PET koennen auch normal grosse Lymphknoten (im CT<10 mm) als tumorbefallen charakterisiert werden (Upstaging). Andererseits kann die PET aufgrund der hoeheren Spezifitaet eine Metastasierung in computertomographisch vergroesserten Lymphknoten oftmals ausschliessen (Downstaging in bis zu 30% der untersuchten Patienten). Eine Aenderung des therapeutischen Prozedere durch die PET-Untersuchung ergab sich bei bis zu 30% aller Patienten und unter Einschluss der Fernmetastasen bei ueber 40% der untersuchten Patienten. Nebennierenmetastasen (Sensitivitaet 100%, Spezifitaet 80%), als auch Leber-, Knochen- und parenchymatoese Lungenmetastasen und abdominelle und zervikale Lymphknotenmetastasen werden mit hoher Sensitivitaet und Spezifitaet detektiert. Bei zerebralen Metastasen ist die MRT im Nachweis eindeutig ueberlegen, bei sehr kleinen Lungenlaesionen (<5 mm) ist die Spiral-CT sensitiver. Der Nachweis des lokalen Rezidivs eines zuvor operierten Lungenkarzinoms ist mit einer Sensitivitaet von 83-100% (Mittel 95%) und einer Spezifitaet von 62-100% (Mittel 81%) moeglich. Auch zur Therapiekontrolle ist die FDG-PET geeignet, da die Abnahme des Glukosemetabolismus mit dem Therapieerfolg korreliert. Problematisch sind inflammatorische Veraenderungen in den ersten Wochen nach Strahlentherapie ('Strahlenpneumonitis'), die ebenfalls zu einem gesteigerten Glukosemetabolismus fuehren koennen, weshalb ein groesserer Zeitabstand (mehrere Wochen bis Monate) nach Strahlentherapie sinnvoll ist. Die FDG-PET hat sich in der Differenzialdiagnostik von

  2. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  3. Borrmann type IV adenocarcinoma versus gastric lymphoma : spiral CT evaluation

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Kim, Yun Hwan; Shin, Kue Hee; Hong, Suk Joo; Kim, Hong Weon; Park, Cheol Min; Chung, Kyoo Byung; Cho, Hyun Deuk

    1999-01-01

    To distinguish the spiral CT findings of Borrmann type IV adenocarcinoma from those of gastric lymphoma with diffuse gastric wall thickening. We retrospectively reviewed the spiral CT scans of 30 patients with Borrmann type IV adenocarcinoma and nine with gastric lymphoma with diffuse gastric wall thickening. In all patients the respective condition was pathologically confirmed by gastrectomy. CT scanning was performed after peroral administration of 500-700ml of water. A total of 120-140 ml bolus of nonionic contrast material was administered intravenously at a flow rate of 3 ml/sec and two-phase images were obtained at 35-45 sec(early phase) and 180 sec(delayed phase) after the start of bolus injection. Spiral CT was performed with 10mm collimation, 10mm/sec table feed and 10mm reconstruction. We evaluated the degree and homogeneity of enhancement of thickened entire gastric wall, and the enhancement pattern of gastric inner layer, as seen on early-phase CT scans. On early and delayed views, the thickness of gastric wall and the presence of perigastric fat infiltration were determined. The enhancement patterns of gastric inner layer were classified as either continuous or discontinuous thick enhancement, thin enhancement, or nonenhancement. The thickness of gastric wall was 1.2-3.5cm(mean 2.2cm) in cases of adenocarcinoma and 1.2-7.6cm(mean 4cm) in lymphoma. Perigastric fat infiltration was seen in 24 patients with adenocarcinoma(80%) and four with lymphoma(44%). In those with adenocarcinoma, the degree of enhancement of entire gastric wall was hyperdense in fifteen patients(50%) and isointense in eleven (37%). Seven patients with lymphoma(78%)showed hypodensity. In those with adenocarcinoma, continuous thick enhancement of gastric inner layer was seen in 18 patients(60%) and discontinuous thick enhancement in nine(30%). In lymphoma cases, no thick enhancement was observed. Thin enhancement of gastric inner layer was demonstrated in three patients with

  4. The potentials of spiral CT for detection of focal liver lesions

    International Nuclear Information System (INIS)

    Helmberger, H.; Kersting-Sommerhoff, B.; Lenz, M.; Kirsten, R.; Bautz, W.

    1996-01-01

    Spiral CT currently is the modality of choice for all aspects of diagnostic evaluation of the liver. Optimal selection of treatment should be based inter alia on the findings obtained by spiral CT with arterial application of contrast medium, as for example S-CTA (primary liver tumors), or S-CTAP (secondary liver tumors). Ultrasonography is the major supplementing modality. In the near future, MR imaging applying liver-specific contrast-enhancing agents is expected to become an important competing technique, and further developments of interest in diagnostic imaging of the liver are in the offing: it is not yet known which technique will be the modality of choice at the onset of the 21st century. (orig.) [de

  5. Einfluss der Lage des aktiven Kontaktes innerhalb des Nucleus subthalamicus auf den Effekt der tiefen Hirnstimulation bei Parkinson Patienten- Eine MRT-basierte Untersuchung

    OpenAIRE

    Wodarg, Fritz

    2013-01-01

    Anhand Prä- und postoperativer MRT-Bilder wird die Lage der Elektroden zur Hochfrequenzstimulation innerhalb des N. subthalamicus bestimmt und mit dem klinischen Ergebnis der Stimulation bei 30 Parkinson Patienten korreliert. Eine Stimulation in lateralen Anteilen des STN bringt signifikant bessere klinische Ergebnisse.

  6. Kyphoplasty and vertebroplasty for spinal trauma; Kyphoplastie und Vertebroplastie bei Wirbelsaeulentraumata

    Energy Technology Data Exchange (ETDEWEB)

    Ahlhelm, F. [Kantonsspital Baden AG, Abteilung fuer Neuroradiologie, Institut fuer Radiologie, Baden (Switzerland); Omidi, R. [Kantonsspital Baden AG, Interventionelle Radiologie, Institut fuer Radiologie, Baden (Switzerland)

    2016-08-15

    Minimally invasive treatment of spinal fractures. Conservative treatment versus spinal surgery. Minimally invasive stabilization techniques, such as percutaneous (assisted) cementoplasty have been introduced as new procedures. Magnetic resonance imaging (MRI), X-rays and computed tomography (CT) are the imaging techniques of first choice. The most important questions concern recent fractures, instability and indications for minimally invasive treatment. Vertebroplasty and kyphoplasty are established methods for the treatment of patients with osteoporosis. Cementoplasty techniques are promising treatment options for traumatic spinal injuries. The application of the techniques should best be carried out in individual cases within the framework of prospective controlled studies. (orig.) [German] Minimal-invasive Behandlung von Wirbelsaeulentraumata. Konservative Behandlung vs. Wirbelsaeulenchirurgie. Als neue Verfahren wurden minimal-invasive Stabilisationstechniken, z. B. perkutane (assistierte) Zementoplastien eingefuehrt. Roentgen, MRT und CT sind die bildgebenden Verfahren der ersten Wahl. Die wichtigsten Fragestellungen sind: Frische Fraktur? Instabilitaet? Indikation fuer minimal-invasive Behandlung ?Vertebroplastie und Kyphoplastie sind bei Osteoporosepatienten etabliert. Bei Wirbelsaeulentraumata sind Zementoplastietechniken vielversprechende Therapieoptionen. Die Anwendung der Techniken sollte im individuellen Fall am besten im Rahmen prospektiver kontrollierter Studien erfolgen. (orig.)

  7. Intraoperative use of an open midfield MR scanner in the surgical treatment of cerebral gliomas; Intraoperative Nutzung eines offenen Mittelfeld-MRT waehrend der chirurgischen Therapie zerebraler Gliome

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Dietrich, J.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany); Trantakis, C. [Klinik und Poliklinik fuer Neurochirurgie, Univ. Leipzig (Germany)

    2003-07-01

    The aim of the present study was to evaluate the effectiveness of intraoperative MRI guidance in achieving more gross-total resection in case of primary brain tumors. We studied 12 patients with low-grade glioma and 19 patients with high-grade glioma who underwent surgery within a vertically open 0.5T MR system. After initial imaging, the resection was stopped at the point in which the neurosurgeon considered the resection complete by viewing the operation field. At this time, intraoperative MRI was repeated (''first control'') to identify any residual tumor. Areas of tumor-suspected tissue were localized and resected, with the exception of tissue adjacent to eloquent areas. Final imaging was carried out before closing the craniotomy. Comparison of ''first control'' and final imaging revealed a decrease of residual tumor volume from 32% to 4.3% in low-grade gliomas, and from 29% to 10% in high-grade gliomas. Intraoperative MRI allows a clear optimization of microsurgical resection of both low-grade and high-grade gliomas. (orig.) [German] Ziel der Untersuchung war es, die Effektivitaet des Einsatzes der intraoperativen MRT bei der Resektion gliogener Hirntumoren zu pruefen. 12 Patienten mit niedriggradigem Gliom und 19 Patienten mit Glioblastom wurden in einem vertikal offenen 0,5-T-MRT operiert. Nach der initialen Bildgebung erfolgte die Resektion bis zu dem Zeitpunkt, an dem der Neurochirurg kein Tumorgewebe mehr im OP-Situs abgrenzen konnte. Zu diesem Zeitpunkt erfolgte eine erneute MRT (''= erste Kontrolle'') zur Visualisierung nur MR-tomographisch darstellbaren Resttumors. Solche Areale wurden im OP-Situs lokalisiert und mit Ausnahme von Strukturen in der Naehe eloquenter Hirnareale reseziert. Vor Verschluss des Schaedels erfolgte eine abschliessende MR-Kontrolle. Durch Einsatz der intraoperativen MRT konnte eine Absenkung des relativen Resttumorvolumens von 32% auf 4,3% bei niediggradigen Gliomen und

  8. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  9. Analysis of hepatic vein variations in healthy people with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Zhang Rong; Li Yong; Shen Jun; Zeng Weike; Li Jieting; Huang Suiqiao; Liang Biling; Liu Chao

    2007-01-01

    Objective: To analyze variations of hepatic vein in healthy people with 64-slice spiral CT. Methods: Seventy-five healthy subjects underwent multi-slice spiral computed (MSCT) hepatic venography. The anatomy of the junction of the hepatic veins with the inferior vena cava and the intrahepatic drainage territory of the hepatic veins and tributaries were evaluated. The hepatic veins were classified according to three anatomic classification (Nakamura's, Marcos's and Kawasaki's classification) methods respectively. Results: There was a common trunk of the middle and left hepatic veins before joining the IVC in 86.7% (65/75)of the cases. In 13.3% (10/75)of the cases, the three main hepatic veins joined the IVC separately. The ratios of Nakamma's classification type A, B, C of hepatic veins were 49.4% (37/75), 37.3% (28/75), and 13.3% (10/75) respectively. The ratios of Marcos's classification type A, B, C of hepatic veins were 56.0% (42/75), 24.0% (18/75), and 20.0% (15/75) respectively. The ratios of Kawasaki's classification type I, II of hepatic vein were 40.0% (30/75) and 60.0% (45/75). Conclusion: Multi-slice spiral CT hepatic venography can provide visualization of peripheral hepatic venous branches in details. (authors)

  10. Fuzzy-neural network in the automatic detection and volumetry of the spleen on spiral CT scans

    International Nuclear Information System (INIS)

    Heitmann, K.R.; Mainz Univ.; Rueckert, S.; Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Uthmann, T.

    2000-01-01

    Purpose: To assess spleen segmentation and volumetry in spiral CT scans with and without pathological changes of splenic tissue. Methods: The image analysis software HYBRIKON is based on region growing, self-organized neural nets, and fuzzy-anatomic rules. The neural nets were trained with spiral CT data from 10 patients, not used in the following evaluation on spiral CT scans from 19 patients. An experienced radiologist verified the results. The true positive and false positive areas were compared in terms to the areas marked by the radiologist. The results were compared with a standard thresholding method. Results: The neural nets achieved a higher accuracy than the thresholding method. Correlation coefficient of the fuzzy-neural nets: 0.99 (thresholding: 0.63). Mean true positive rate: 90% (thresholding: 75%), mean false positive rate: 5% (thresholding>100%). Pitfalls were caused by accessory spleens, extreme changes in the morphology (tumors, metastases, cysts), and parasplenic masses. Conclusions: Self-organizing neural nets combined with fuzzy rules are ready for use in the automatic detection and volumetry of the spleen in spiral CT scans. (orig.) [de

  11. Tumor-like diseases of the knee joint; Tumoraehnliche Erkrankungen im Kniegelenk

    Energy Technology Data Exchange (ETDEWEB)

    Freyschmidt, J. [Klinikum Bremen-Mitte, Beratungsstelle und Referenzzentrum fuer Osteoradiologie, Bremen (Germany)

    2012-11-15

    Radiological diagnostics of tumor-like lesions of the knee joint. Magnetic resonance imaging (MRI), computed tomography (CT) and X-ray imaging. Up to now there have been no studies regarding sensitivity and specificity of the various diagnostic tools (MRI, CT, X-ray) for the visualization of soft tissue tumors of the knee. The method of first choice for detecting soft tissue tumors and tumor-like lesions in the knee joint is MRI. (orig.) [German] Radiologische Diagnostik tumoraehnlicher Laesionen im Kniegelenk. Eingesetzte Verfahren sind die MRT, CT und Projektionsradiographie. Da es sich um Weichteiltumoren handelt, ist die MRT bei der Diagnostik dominierend. Sensitivitaet und Spezifitaet sind unserer Kenntnis nach bisher nicht untersucht worden. In manchen Faellen werden jedoch noch zusaetzliche Roentgen- oder CT-Bilder benoetigt. Bei Verdacht auf einen Tumor im Kniegelenk wird als erste Untersuchung eine MRT empfohlen. (orig.)

  12. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  13. Pitfalls in the use of spiral CT for identification of intracranial aneurysms

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Dorsch, N.W.C.

    1999-01-01

    We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms. (orig.)

  14. Systematics of glenohumoral and acromioclavicular arthritis; Systematik der glenohumeralen und akromioklavikulaeren Arthrose

    Energy Technology Data Exchange (ETDEWEB)

    Seifarth, A. [Klinikum Augsburg, Klinik fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Augsburg (Germany); Roemer, F. [Klinikum Augsburg, Klinik fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Augsburg (Germany); Universitaetsklinikum Erlangen, Radiologisches Institut, Erlangen (Germany)

    2015-03-01

    A common risk factor for osteoarthritis (OA) of the glenohumeral joint is instability and is often observed as a sequel to dislocation. Altered biomechanics will ultimately result in joint degeneration including osteophyte development at the lower margin of the humerus, glenoidal cartilage loss and surface deformity. An OA of the glenohumeral joint is often coexistent with soft tissue derangement of the shoulder. In advanced stages defects of the rotator cuff and OA of the glenohumeral joint may accelerate disease progression. Degenerative changes of the acromioclavicular joint (AC joint) are commonly seen in older persons with only modest correlation with clinical symptoms. Symptomatic OA of the AC joint is often concomitantly observed with degenerative changes of the glenohumeral joint. Standard radiographs are the basis of a structural assessment of shoulder OA but lack correlation with clinical symptoms and are insensitive for the detection of early degenerative changes. Magnetic resonance imaging (MRI) provides increased sensitivity for the detection of cartilage defects and reveals relevant soft tissue changes, such as lesions of the glenoid labrum and capsuloligamentous structures, which are seen in conjunction with instability. It is also the method of choice to detect clinically relevant bone marrow edema-like lesions or synovial changes that are associated with symptomatic OA. Standard radiographs are not applicable for detection of early degenerative changes. Once OA is suspected clinically, MRI is the method of choice for further structural assessment. The administration of an intravenous contrast agent is useful for assessing synovitis, which commonly correlates with clinical disease manifestations. For preoperative and surgical planning of joint replacement, MRI or CT should be used. (orig.) [German] Eine haeufige Ursache der Omarthrose ist die Mikro- und Makroinstabilitaet, oft infolge von Luxationen. Bei veraenderter Biomechanik kommt es im Verlauf

  15. Advances in fusion of PET, SPET, CT und MRT images

    International Nuclear Information System (INIS)

    Pietrzyk, U.

    2003-01-01

    Image fusion as part of the correlative analysis for medical images has gained ever more interest and the fact that combined systems for PET and CT are commercially available demonstrates the importance for medical diagnostics, therapy and research oriented applications. In this work the basics of image registration, its different strategies and the mathematical and physical background are described. A successful image registration is an essential prerequisite for the next steps, namely correlative medical image analysis. Means to verify image registration and the different modes for integrated display are presented and its usefulness is discussed. Possible limitations in applying image fusion in order to avoid misinterpretation will be pointed out. (orig.) [de

  16. Wedge-shaped parenchymal enhancement peripheral to the hepatic hemangioma : two-phase spiral CT findings

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han, Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Song, Chi Sung; Choi, Byung Ihn

    2000-01-01

    To determine the incidence of hepatic hemangiomas associated with wedge-shaped parenchymal enhancements adjacent to the tumors as seen on two-phase spiral CT images obtained during the hepatic arterial phase and to characterize the two-phase spiral CT findings of those hemangiomas. One hundred and eight consecutive hepatic hemangiomas in 63 patients who underwent two-phase spiral CT scanning during an 11-month period were included in this study. Two-phase spiral CT scans were obtained during the hepatic arterial phase (30-second delay) and portal venous phase (65-second delay) after injection of 120 mL of contrast material at a rate of 3 mL/sec. We evaluated the frequency with which wedge-shaped parenchymal enhancement was adjacent to the hemangiomas during the hepatic arterial phase and divided hemangiomas into two groups according to whether or not wedge-shaped parenchymal enhancement was noted (Group A and Group B). The presence of such enhancement in hemangiomas was correlated with tumor size and the grade of intratumoral enhancement. In 24 of 108 hemangiomas, wedge-shaped parenchymal enhancement adjacent to hepatic tumors was seen on two-phase CT images obtained during the hepatic arterial phase. Mean hemangioma size was 22mm in group A and 24mm in group B. There was no statistically significant relationship between lesion size and the presence of wedge-shaped parenchymal enhancement adjacent to a hemangioma. In 91.7% and 100% of tumors in Group A, and in 9.6% and 17.8% in Group B, hemangiomas showed more than 50% intratumoral enhancement during the arterial and portal venous phase, respectively. Wedge-shaped parenchymal enhancements peripheral to hepatic hemangiomas was more frequently found in tumors showing more than 50% intratumoral enhancement during these two phases (p less than 0.01). Wedge-shaped parenchymal enhancements is not uncommonly seen adjacent to hepatic hemangiomas on two-phase spiral CT images obtained during the hepatic arterial phase. A

  17. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  18. Radiological diagnostics of multiple myeloma; Radiologische Diagnostik des multiplen Myeloms

    Energy Technology Data Exchange (ETDEWEB)

    D' Anastasi, M.; Grandl, S.; Reiser, M.F.; Baur-Melnyk, A. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2014-06-15

    ). Projektionsradiographie (Skelettstatus) zur Erfassung von Osteolysen, Osteoporose oder Frakturen. Die Ganzkoerper-CT stellt hochsensitiv die Osteolysen, die Ganzkoerper-MRT das Ausmass der Knochenmarkinfiltration dar. Die Positronenemissionstomographie(PET)-CT kann zusaetzlich die aktiven Myelomlaesionen detektieren und wichtige Informationen fuer den Therapieverlauf geben. Nach den Ergebnissen mehrerer Studien sind die Schnittbildverfahren dem Roentgenskelettstatus ueberlegen. Die Ganzkoerper-MRT ist sowohl fuer den Nachweis fokaler Laesionen als auch einer diffusen Infiltration signifikant sensitiver als die Ganzkoerper-CT. Die PET-CT zeigt eine vergleichbare Sensitivitaet mit der Ganzkoerper-MRT. Aufgrund der hoeheren Sensitivitaet bei der Detektion von Myelomlaesionen sollten die Ganzkoerper-CT und die Ganzkoerper-MRT die Projektionsradiographie ersetzen. Bei Verdacht auf ein MM sollte bei der initialen Diagnostik eine Ganzkoerper-CT durchgefuehrt werden. Werden hier keine Herde gefunden, sollte, falls verfuegbar, eine Ganzkoerper(GK)-MRT oder zumindest eine MRT der Wirbelsaeule und des Beckens durchgefuehrt werden. Falls eine GK-MRT in der initialen Diagnostik durchgefuehrt wurde, sollte bei fokalen Herden eine ergaenzende Ganzkoerper-CT erfolgen, um das Ausmass der Osteolysen zu erfassen und das Frakturrisiko abzuschaetzen. Bei der monoklonalen Gammopathie unklarer Signifikanz (MGUS), beim solitaeren und beim ''smoldering'' Myelom sollte, falls verfuegbar, die GK-MRT eingesetzt werden, da hiervon die Prognose und das Therapiekonzept bei vorhandenen Infiltraten betroffen sind. (orig.)

  19. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  20. Spiral CT portography: correlation with different injection rate

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Chen Zuwang; Chen Gang; Chen Jin; Chen Huiming

    2000-01-01

    Objective: To choose optimal injection rate in spiral CT portography(CTP) by comparing 3D CTP images using different injection rates. Methods: Thirty-seven patients were randomly divided into 2 groups (11 and 26 cases in each group). Single-level dynamic scan was completed at the first liver hilus, starting at 15s or 30s after initial contrast injection(2 ml/kg) with injection rate 1.5 ml/s (slow group) or 3.0 ml/s (rapid group). The continuous scan were repeated every 5s for 120s or 135s. ROI was used to measure the CT value of the portal vein and the liver parenchyma, respectively, and then the time-density curves were drawn. Spiral CT portography were performed at injection rate of 1.5 ml/s or 3.0 ml/s as the delay time designed described above, including 98 cases in rapid group and 12 cases in slow group. Both MPVR (multi-projection volume reconstruction) and MIP (maximum intensity projection) were employed for reconstruction. All images were ranked according to the grade of portal vein, the different CT value between the portal vein and the liver parenchyma, the edge's definition of blood vessel, the grade of hepatic vein and the display of IVC by 2 radiologists. Results: The maximum density difference in average between the portal vein and the liver parenchyma was 53.4 HU and 83.9 HU, respectively (t = 16.418, P < 0.001) in slow group and rapid one, and the mean reaching time was 80s and 60s, respectively (t = 13.394, P < 0.001). In slow injection group, the average score of MPVR image was 9.3, while it was 12.5 (t = 3.514, P < 0.01) in rapid injection group. Rapid group was better than slow one at the PV-L, the grade of the portal vein, and the edge's definition of blood vessel. Conclusion: Using rapid injection rate (3.0 ml/s), the maximum density difference between the portal vein and the liver parenchyma increases, and the mean reaching time shortens. The quality of 3D CTP image of rapid injection rate (3.0 ml/s) is superior to that of slow injection rate

  1. Multiparametric MRI of the prostate. Important radiological findings for urologists; Multiparametrische MRT der Prostata. Wichtige radiologische Befunde fuer den Urologen

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany)

    2017-08-15

    High prevalence of prostate cancer with multifocality and biological heterogeneity. Insufficient conventional urological diagnostics. Discrimination between significant and insignificant cancer needed. Digital rectal examination, prostate-specific antigen (PSA) serum level, systematic transrectal ultrasound (TRUS)-guided prostate biopsy. Multiparametric magnetic resonance imaging (mpMRI) including T2-weighted (T2w), diffusion-weighted and dynamic contrast-enhanced MRI according to the prostate imaging reporting and data system (PIRADS), MR-targeted biopsy, most frequently MR/TRUS image fusion biopsy. Prostate cancer is characterized by low signal intensity on T2w MRI, restricted water diffusion and pronounced and early uptake of contrast enhancement. Sensitivity and specificity according to the current literature are ca. 80% and 90%, respectively. In cases of suspected prostate cancer, most accurate are mpMRI according to PIRADS and in cases of positive findings, MRI-targeted biopsy, most frequently as MRI/TRUS image fusion biopsy. (orig.) [German] Hohe Praevalenz des Prostatakarzinoms mit Multifokalitaet und biologischer Heterogenitaet. Unzureichende konventionelle urologische Diagnostik. Unterscheidung klinisch signifikanter von klinisch nicht signifikanten Karzinomen erforderlich. Digitale rektale Untersuchung, Serum-PSA (prostataspezifisches Antigen), transrektale Sonographie (TRUS), systematische transrektale TRUS-Biopsie. Multiparametrische Magnetresonanztomographie (mpMRT) mit T2w- und diffusionsgewichteten sowie dynamischen kontrastmittelverstaerkten T1w-Sequenzen, dem Standard nach dem Prostate Imaging Reporting and Data System (PIRADS) entsprechend. MR-unterstuetzte Biopsie, meist MR-/TRUS-Fusionsbiopsie. Prostatakarzinome sind typischerweise T2-hypointens mit eingeschraenkter Diffusion und zeigen eine rasche Kontrastmittelanflutung. Nach der Literatur betragen Sensitivitaet und Spezifitaet der mpMRT ca. 80 bzw. 90 %. Fuer die Abklaerung bei Verdacht auf

  2. Multi-slice spiral CT perfusion imaging of chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shao Yanhui; Qian Nong; Xue Yuejun; Dao Yinhong

    2008-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) perfusion imaging in chronic obstructive pulmonary disease (COPD). Methods: Twenty COPD patients and 20 volunteers underwent 8-row detector spiral CT (MSCT) perfusion imaging using cine scan mode with 5 mm slice thickness, 0.5 s rotation time and a total scan time of 45 s with 5 s intervals. 60 ml contrast agent (300 nag I/ml) were administered at a rate of 4 ml/s from the forearm superficial vein. The imaging data were transferred to a workstation. A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software, the blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) were measured. Results: Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers. The BF, BV, PS in COPD patients was (24.77±11.49) ml·min -1 ·100 g -1 , (2.48±1.02) ml/100 g and (2.75±1.13) ml· min -1 ·100 g -1 respectively. In volunteers was (290.14±107.59) ml·min -1 ·100 g -1 , (16.51 ± 5.98) ml/100 g, (8.80±3.03) ml·min -1 ·100 g -1 respectively. The MTT in COPD patients and volunteers was (10.58±4.85) s and (4.50±1.71)s respectively. The BF, BV and PS in COPD patients was lower than the volunteers, the MTY was higher (P<0.01). Conclusion: MSCT perfusion imaging is helpful for the diagnosis of COPD. (authors)

  3. Evaluation of spiral CT in staging of colon and rectum carcinoma

    International Nuclear Information System (INIS)

    Hundt, W.; Braunschweig, R.; Reiser, M.

    1999-01-01

    The purpose of our study was to evaluate the capability of a subsecond spiral-CT scanner using two contrast medium phases in staging of colorectal cancer. In our study we included 37 patients with proven rectum or colon carcinoma. Spiral CT was performed following tap-water enema of the colon in the arterial and venous phases of contrast medium enhancement. Our results were compared with the findings of pathological examination after surgery. The tumor's size and extension were evaluated in the arterial and venous phases, the lymph nodes in the venous phase of the CT scan. The tumor was in the rectum (n = 14), sigma (n = 11), descending colon (n = 6), and cecum (n = 6). Two-phase spiral CT had a sensitivity of 97.2 % in the arterial phase and 89.1 % in the venous phase in detecting the carcinoma. The staging results were in the arterial phase in 30 of 37 cases (81.0 %) and in the venous phase in 24 of 37 cases (64.8 %) according to pathology. In 27 of 32 patients (84.3 %) lymph nodes were detected. The correct classification of the N-stage was possible in 23 of 34 cases (67.6 %). The combined use of arterial and venous phases in staging of colorectal cancer can improve the T- and N-stage classification in comparison with using only one contrast medium phase. The arterial phase is superior compared with the venous phase for local tumor staging and the venous phase is used for lymph node assessment. (orig.) (orig.)

  4. Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen

    Energy Technology Data Exchange (ETDEWEB)

    Hefele-Roedel, B. [Radiologische Klinik Innenstadt, Univ. Muenchen (Germany); Vogl, T.J. [Radiologische Klinik Innenstadt, Univ. Muenchen (Germany); Lochbuehler, H. [Dr. v. Haunersches Kinderspital, Kinderchirurgische Klinik, Univ. Muenchen (Germany); Lissner, J. [Radiologische Klinik Innenstadt, Univ. Muenchen (Germany)

    1995-01-01

    Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den Okzipitalkondylen, die Bestimmung des Frakturausmasses und die genaue Frakturlokalisation in Rekonstruktionen (koronar, sagittal, 3-D). Bei komplexen Begleitverletzungen, wie Blutungen (zerebral, spinal und in den Halsweichteilen) oder zum Nachweis einer Hirnstammkontusion, erwies sich der Einsatz der MRT als vorteilhaft. Mit der MRT laesst sich ein deutlich hoeherer Weichteilkontrast, insbesondere spinal und zerebral, erzielen. (orig.)

  5. Advanced single-slice rebinning for tilted spiral cone-beam CT

    International Nuclear Information System (INIS)

    Kachelriess, Marc; Fuchs, Theo; Schaller, Stefan; Kalender, Willi A.

    2001-01-01

    Future medical CT scanners and today's micro CT scanners demand cone-beam reconstruction algorithms that are capable of reconstructing data acquired from a tilted spiral trajectory where the vector of rotation is not necessarily parallel to the vector of table increment. For the medical CT scanner this case of nonparallel object motion is met for nonzero gantry tilt: the table moves into a direction that is not perpendicular to the plane of rotation. Since this is not a special application of medical CT but rather a daily routine in head exams, there is a strong need for corresponding reconstruction algorithms. In contrast to medical CT, where the special case of nonperpendicular motion is used on purpose, micro CT scanners cannot avoid aberrations of the rotational axis and the table increment vector due to alignment problems. Especially for those micro CT scanners that have the lifting stage mounted on the rotation table (in contrast to setups where the lifting stage holds the rotation table), this kind of misalignment is equivalent to a gantry tilt. We therefore generalize the advanced single-slice rebinning algorithm (ASSR), which is considered a very promising approach for medical cone-beam reconstruction due to its high image quality and its high reconstruction speed [Med. Phys. 27, 754-772 (2000)], to the case of tilted gantries. We evaluate this extended ASSR approach (which we will denote as ASSR + , for convenience) in comparison to the original ASSR algorithm using simulated phantom data for reconstruction. For the case of nonparallel object motion ASSR + shows significant improvements over ASSR, however, its computational complexity is slightly increased due to the broken symmetry of the spiral trajectory

  6. New aspects from legislation, guidelines and safety standards for MRI; Neues aus Gesetzen, Richtlinien und Sicherheitsstandards fuer die MRT

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany); Trattnig, S. [Exzellenzzentrum Hochfeld-Magnetresonanz, Medizinische Universitaet Wien, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2015-08-15

    Betriebsanleitung der MR-Scanner. Die verpflichtenden Inhalte der Betriebsanleitung werden in einer zentralen Norm der International Electrotechnical Commission (IEC) 60601-2-33 geregelt. In dieser Norm wurde juengst die Anwendung statischer Magnetfelder in der MRT bis zu 8 Tesla (T) in der klinischen Routine (kontrollierte Betriebsart 1. Stufe) zugelassen. Die ebenfalls notwendige CE-Zertifizierung der Ultrahochfeldscanner (7-8 T) in Europa ist fuer zukuenftige Geraete zu erwarten. Bestehende Installationen werden nicht automatisch zertifiziert, sondern behalten ihren experimentellen Status. Die aktuelle Erweiterung der IEC 60601-2-33 fuehrt eine neue Zusatzoption, die sog. ''fixed parameter option'' (FPO) ein. Diese Option kann zusaetzlich zu den etablierten Betriebsarten geschaltet werden und definiert eine fixe Geraetekonstellation und bestimmte Parameter des Energieoutputs von MR-Scannern, die zukuenftig die Untersuchungen von Implantatpatienten vereinfachen soll. Die Beschaeftigung schwangerer Mitarbeiterinnen in einer MRT-Einrichtung ist nach wie vor nicht allgemein in Europa geregelt. In Deutschland und Oesterreich wurden 2014 in Teilregionen Beschaeftigungsverbote fuer Schwangere und Stillende im der MR-Kontrollzone (0,5 mT) erteilt. Zugrunde liegt die meist ungeklaerte Frage der Anwendbarkeit von Grenzwerten fuer Beschaeftigte (Extremitaetenexposition fuer statische Magnetfelder bis 8 T erlaubt) oder der Grenzwerte fuer die Allgemeinbevoelkerung (maximal bis 400 mT). Das Verwerfen von Muttermilch nach i.v.-Gabe von gadoliniumhaltigen Kontrastmitteln bei einer stillenden Frau wird laut Gesellschaft fuer urogenitale Radiologie (ESUR) nur noch bei Gabe von Kontrastmitteln der Nephrogenic-systemic-fibrosis(NSF)-Hochrisikoklasse empfohlen. (orig.)

  7. Spiral CT features and anatomic basis of posterior pararenal space involvement in acute pancreatitis

    International Nuclear Information System (INIS)

    Min Pengqiu; Yan Zhihan; Yang Hengxuan; Liu Zaiyi; Song Bin; Wu Bing; Zhang Jin; Liu Rongbo

    2005-01-01

    Objective: To evaluate spiral CT features and anatomic basis of the posterior pararenal space (PPS) involvement in acute pancreatitis (AP). Methods: CT images of 87 cases with AP were retrospectively studied with focus on spiral CT features, incidence of the PPS involvement, and its correlations with the posterior renal fascia or lateroconal fascia. Results: Our study showed that the incidence of the PPS involvement was 47% (41/87), with Grade A 53% (46/87), Grade B 24%(21/87), and Grade C 23% (20/87), and Grade 0 53% (46/87), Grade I 22% (19/87), and Grade II 25% (22/87), respectively. The pancreatitis fluid collection in the PPS was continuous with that in the anterior pararenal space or with the fluid between the two laminae of the posterior renal fascia. In 3 follow-up cases, pseudocysts in the PPS were continuous with that in anterior pararenal space below the cone of renal fascia. Conclusion: Spiral CT features of the PPS involvement varies from mild inflammatory changes to fluid collection or phlegmonous mass. Fluid within anterior pararenal space in AP flows into the PPS by three routes. (authors)

  8. Neurogenic myopathies and imaging of muscle denervation; Neurogene Myopathien und Bildgebung der Muskeldenervation

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, M. [Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany); Wolf, C. [Reha-Zentrum Gernsbach, Neurologie, Gernsbach (Germany); Weber, M.A. [Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2017-12-15

    , chronische Kompressionen sowie neurodegenerative, inflammatorische, metabolische und neoplastische Prozesse. Anamnese, klinisch-neurologische Untersuchung und elektrophysiologische Tests einschliesslich Elektromyographie (EMG) und Testung der Nervenleitgeschwindigkeit sind notwendig. Die EMG stellt den Goldstandard in der Diagnose von Muskeldenervierung dar. Ergaenzende bildgebende Methoden, vor allem die Magnetresonanztomographie (MRT) koennen teils sinnvolle Informationen liefern. Bei akuter und subakuter Denervierung weist die Muskulatur in der MRT Oedeme, ADC(''apparent diffusion coefficient'')-Erhoehung und gesteigerte Perfusion auf. Die mittels MRT nachweisbaren Veraenderungen denervierter Muskulatur sind relativ unspezifisch, erreichen aber eine vergleichbar hohe Sensitivitaet wie die EMG. Mittels dezidierter MR-Neurographie kann oft auch die ursaechliche Schaedigung des/der innervierenden Nerven visualisiert werden. Abgesehen von der mit der EMG vergleichbaren Sensitivitaet eignet sich die MRT zur Beurteilung von Muskeln, die einer Nadelelektromyographie nicht zugaenglich sind. Aufgrund ihres nichtinvasiven Charakters ist die MRT auch ideal fuer Verlaufsuntersuchungen. Oft ergaenzt die MRT die Diagnostik neurogener Myopathien sinnvoll. Ausmass und Verteilungsmuster der muskulaeren Veraenderungen lassen haeufig auf die Lokalisation der ursaechlichen Nervenschaedigung schliessen. Oft ermoeglichet die MRT eine korrekte Diagnosestellung oder zumindest eine Eingrenzung moeglicher Differenzialdiagnosen. (orig.)

  9. Imaging in smoldering (asymptomatic) multiple myeloma. Past, present and future; Bildgebung bei ''smoldering'' (asymptomatischem) multiplem Myelom. Vergangenheit, Gegenwart und Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    Bhutani, M.; Landgren, O. [Center for Cancer Research, National Cancer Institute, National Institutes of Health, Multiple Myeloma Section, Lymphoid Malignancies Branch, Bethesda, MD (United States)

    2014-06-15

    imaging techniques need to be validated in prospective clinical trials assessing the SMM to multiple myeloma transition, with the aim of enabling appropriate management decisions. Efforts are also needed to improve the costs and availability of whole-body MRI and/or FDG PET/CT, in order to facilitate their widespread adoption as first-line detection modalities. Future clinical trials of therapeutic agents using earlier detection strategies will have to be carefully designed and take into consideration the risk of lead-time and length-time biases, which might falsely demonstrate longer overall survival. The English full text version of this article is available at SpringerLink (under ''Supplemental''). (orig.) [German] Aktuelle klinische Studien sprechen fuer eine Therapie des ''smoldering multiple myeloma'' (SMM) mit hohem Progressionsrisiko schon bei der Diagnosestellung und nicht erst zum Zeitpunkt der Progression in ein symptomatisches multiples Myelom (MM). Die Frueherkennung einer Knochen- und/oder Knochenmarkbeteiligung durch entsprechende sensitive Bildgebungsverfahren kann zur Ermittlung von SMM-Patienten mit hohem Risiko fuer eine Progression beitragen. Nach aktuellen Konsensusleitlinien (2011) ist die Roentgenuntersuchung des Skeletts ein Grundpfeiler der Beurteilung einer Knochenbeteiligung bei Diagnosestellung und in Verlaufskontrollen wegen eines SMM. Jedoch hat die Roentgenuntersuchung des Skeletts eine geringe Sensitivitaet fuer Knochenlaesionen und liefert keine Informationen zu Knochenmarkveraenderungen. Moderne bildgebende Verfahren wie die Fluordeoxyglukose-Positronenemissionstomographie-Computertomographie (FDG-PET-CT) und die Magnetresonanztomographie (MRT) liefern zusammen mit innovativen Funktionsuntersuchungen eine bessere Einschaetzung allgemeiner Veraenderungen im Knochenmark- und im Knochenkompartiment. Mit diesen Verfahren kann die beginnende Progression vom SMM zum MM quantitativ objektiviert werden

  10. MR imaging of the prostate; MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Haas, M.; Hamm, B. [Charite Campus Benjamin Franklin, Klinik fuer Radiologie, Berlin (Germany)

    2015-12-15

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [German] Das Prostatakarzinom ist in Deutschland die haeufigste Krebserkrankung des Mannes, wobei ein deutlicher Unterschied zwischen Inzidenz und Mortalitaet besteht. Die Detektion des Prostatakarzinoms basiert auf klinischer und laborchemischer Untersuchung (prostataspezifisches-Antigen[PSA]-Wert) sowie der transrektalen Ultraschalluntersuchung mit randomisierter Biopsie. Die multiparametrische MR-Tomographie kann zur Detektion des Prostatakarzinoms, insbesondere bei negativer Biopsie vor einer erneuten Biopsie wertvolle diagnostische Informationen liefern. Zudem wird zunehmend die MRT-Ultraschall-Fusionsbiopsie in der Diagnostik eingesetzt, wodurch die Detektionsrate des Prostatakarzinoms deutlich gesteigert werden kann. Mit Einfuehrung der PI-RADS-Klassifikation (Prostate Imaging-Reporting and Data System) konnte zudem eine Standardisierung der Befundung erreicht werden, was die Akzeptanz der MRT der Prostata in der Urologie erhoeht hat. (orig.)

  11. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system; MRT-gestuetzte Markierung und Stanzbiopsie suspekter Mammalaesionen. Moeglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Horn, L.C. [Inst. fuer Pathologie, Universitaetsklinikum Leipzig (Germany); Leinung, S. [Chirurgische Klinik I, Universitaetsklinikum Leipzig (Germany); Briest, S. [Frauenklinik, Universitaetsklinikum Leipzig (Germany)

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (<10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. Conclusion. Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out in a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy. (orig.) [German] Zielsetzung. In den letzten Jahren wurde eine Vielzahl von Systemen zur praeoperativen Markierung oder Biopsie MRT-suspekter Mammalaesionen vorgestellt. Ziel unserer Untersuchungen war es, Moeglichkeiten solcher Verfahren an einem vertikal offenen 0,5-T-Magneten (SIGNA SP/i, GE Medical Systems) zu entwickeln, zu erproben und in die klinische Routine zu

  12. Radiological diagnostics of malignant tumors of the musculoskeletal system in childhood and adolescence; Radiologische Diagnostik maligner Tumoren des Muskuloskelettalsystems im Kindes- und Adoleszentenalter

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, S.F.; Krestan, C.R. [Medizinische Universitaet Wien, Klinische Abteilung fuer Neuroradiologie und muskuloskelettale Radiologie, Wien (Austria); Hojreh, A.; Hoermann, M. [Medizinische Universitaet Wien, Klinische Abteilung fuer Allgemeine Radiologie und Kinderradiologie, Wien (Austria)

    2008-10-15

    bildgebende Diagnostik maligner muskuloskelettaler Tumoren umfasst im Wesentlichen das konventionelle Roentgen, die Computertomographie (CT) und Magnetresonanztomographie (MRT) sowie die nuklearmedizinischen Untersuchungen Szintigraphie, Positronenemissionstomographie (PET) und PET-CT. (orig.)

  13. Degenerative diseases of the spine. Rare and often unrecognized causes of pain syndromes; Degenerative Erkrankungen der Wirbelsaeule. Seltene und oft verkannte Ursachen von Schmerzsyndromen

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, A.; Triantafyllou, M.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Birkenmaier, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Orthopaedische Klinik und Poliklinik (Germany)

    2006-06-15

    verlaufen. Diskutiert werden Inzidenz, Pathophysiologie, Bildgebung und Schmerzsymptomatik der Rueckenschmerzursachen. Anulusrisse werden haeufig bei asymptomatischen Individuen gefunden, konnten aber in Korrelation mit der provokativen Diskographie mit einer lumbalen Schmerzsymptomatik in Verbindung gebracht werden. Uebergangsstoerungen koennen zu einem Nearthros zum Os sacrum/Os ileum und zur Degeneration fuehren oder zu einer reaktiven Hypermobilitaet mit Bandscheibendegeneration in der darueber liegenden Hoehe. Die erosive Osteochondrose, Typ Modic I, zeichnet sich durch ein abschlussplattennahes Knochenmarkoedem aus, das meist starke Schmerzen hervorruft und zu starken Einschraenkungen im taeglichen Leben fuehrt. Die wichtigste Differenzialdiagnose ist die Spondylodiszitis. Schmorl-Knoten koennen ein erhebliches umgebendes Knochenmarkoedem aufweisen und mit Metastasen verwechselt werden. Zur Diagnostik der akuten Ermuedungsfraktur der Interartikularportion, die aufgrund ihrer Lage haeufig uebersehen wird, sollte eine Kombination aus MRT und CT erfolgen. Synoviale Zysten der Facettengelenke koennen zu radikulaeren Symptomen fuehren. Die Insuffizienzfraktur des Sakrums wird aufgrund einer starken szintigraphischen Anreicherung und ihres Signalverhaltens in der MRT haeufig mit einer Metastasierung verwechselt. Wegweisend ist die CT. In die Differenzialdiagnostik sollten seltenere Ursachen wie Anulusrisse, Uebergangsstoerungen, aktivierte Schmorl-Knoten, synoviale Zysten der Facettengelenke, Ermuedungsfrakturen der Interartikularportion und des Sakrums einbezogen und insbesondere zur Metastasierung abgegrenzt werden. (orig.)

  14. Spiral-CT-angiography of acute pulmonary embolism: factors that influence the implementation into standard diagnostic algorithms

    International Nuclear Information System (INIS)

    Bankier, A.; Herold, C.J.; Fleischmann, D.; Janata-Schwatczek, K.

    1998-01-01

    Purpose: Debate about the potential implementation of Spiral-CT in diagnostic algorithms of pulmonary embolism are often focussed on sensitivity and specificity in the context of comparative methodologic studies. We intend to investigate whether additional factors might influence this debate. Results: The factors availability, acceptance, patient-outcome, and cost-effectiveness-studies do have substantial influence on the implementation of Spiral-CT in the diagnostic algorithms of pulmonary embolism. Incorporation of these factors into the discussion might lead to more flexible and more patient-oriented algorithms for the diagnosis of pulmonary embolism. Conclusion: Availability of equipment, acceptance among clinicians, patient-out-come, and cost-effectiveness evaluations should be implemented into the debate about potential implementation of Spiral-CT in routine diagnostic imaging algorithms of pulmonary embolism. (orig./AJ) [de

  15. Virtual endoscopy using spiral CT in patients with carcinomas of the hypopharynx and larynx

    International Nuclear Information System (INIS)

    Song, Sang Gook; Seo, Jeong Jin; Chung, Tae Woong; Kim, Hyeong Kil; Jeong, Gwang Woo; Jeong, Yong Yeon; Kang, Heoung Keun; Cho, Jae Sik

    2000-01-01

    To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the one case of glottic carcinoma was not detected. Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharyngeal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use ma complement that of axial CT. (author)

  16. Shallow and deep breath lung tumor volume as estimated by spiral volumetric CT in comparison to standard axial CT using virtual simulation

    International Nuclear Information System (INIS)

    Quader, M.A.; Kalend, A.M.; Deutsch, M.; Greenberger, J.S.

    1995-01-01

    Purpose/Objective: In order to assess an individual patient tumor volume (TV) margins that are sufficient to design a beam-eye-view (BEW) conformal portal, the radiographic extent of gross tumor volume (GTV) dimensions and its fluctuation with breathing are measured by fast spiral CT scanning of patients treated for Stage II, III lung cancers using 5-6 field multi-collimated conformal beams. Materials and Methods: Over the course of conformal radiotherapy for lung cancer, a full thorax CT scans of the patient were taken by conventional axial CT scanning with patients immobilized in the treatment position and breathing normally. Patient(s) with good pulmonary function test (PFT) status were selected to perform deep breathing and re-scanned by fast spiral techniques in order to re-acquire the tomographic variation in the (GTV) with breathing. A Picker spiral ZAP-100 software running on the AQSim-PQ-2000 was used with a variable helical pitch of 1.0, 1.5 and 2.0. The variable pitch spirals were limited to tumor bed, diaphragm and lung apex area for measurements. Effect of breathing motion along x,y,z direction were then assessed for each beam-eye-view portal as seen in digitally reconstructed radiography (DRR) at the treated gantry angle. Results: Comparison of axial and spiral scans shows the progression of lung and diaphram motion with breathing can be gauged better in spiral scans. The movement of the diaphragm during shallow breathing has been found to be 2-3cm by measuring the distance between the most inferior and superior slices where diaphragm is present. The variation of the tumor dimensions along AP/PA and lateral direction seems to be less sensitive to breathing than those along inferior-superior direction. Conclusion: The fast spiral CT scanning is sensitive to patient lung motion and can be used to determine the fluctuations of the gross tumor volume with breathing. The extent of the fluctuation is location dependent and increases as one moves from the

  17. Clinical application of low-dose spiral CT for orthodontics

    International Nuclear Information System (INIS)

    Xie Na; Gan Yungen; Shu Huang; Lin FeiFei; Li Zhiyong; Sun Jie

    2009-01-01

    Objective: To determine the effect of reducing the value of mA or kV on the image quality and the radiation dose of the patients undergoing low-dose spiral CT for orthodontics. Methods: Thirty patients were divided into three groups, each group has 10 patients. They were group 1 (80 kV and 200 mA), group 2 (120 kV and 80 mA), group 3 (120 kV and 200 mA) The volume CT dose index (CTDI) was recorded and the average dose-length produce (DLP) was calculated in three groups,respectively. Image quality of three groups were compared and scored by two radiologists, and the results were statistically analysed. Results: The CTDI and DLP of 80 kV group (group 2) were 8.7 mGy and (36.80 ± 3.60) mGy · cm, respectively, those of 80 mA group (group 3) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively, and those of conventional-dose group (group 1) were 19.6 mGy and (82.14 ± 7.18) mGy · cm, respectively. There was no significant difference among three groups in diagnostic image quality. Conclusions: Low-dose spiral CT for orthodontics, especially the low-kV scan, may decrease the radiation exposure and guarantee the image quality. (authors)

  18. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI; Indirekte MR-Phlebografie: Kontrastmittelprotokolle, Nachverarbeitung und Kombination mit Lungenemboliediagnostik in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, A.; Bachmann, G. [Diagnostische Radiologie, Kerckhoff-Klinik, Bad Nauheim (Germany); Rominger, M. [Diagnostische Radiologie, Phillips-Univ. Marburg (Germany); Schoenburg, M. [Herzchirurgie, Kerckhoff-Klinik, Bad Nauheim (Germany)

    2004-07-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [German] Ziel: Integration der MR-Phlebografie in ein umfassendes Konzept der MRT-Diagnostik bei Verdacht auf Lungenembolie (LE). Untersuchung des Einflusses von Kontrastmittelmenge, -bolusform und Verzoegerungszeit sowie der Nachverarbeitung auf die diagnostische Qualitaet von MR-Phlebografien. Material und Methode: Bei 48 konsekutiven stationaeren Patienten mit Verdacht auf Beinvenenthrombose (TVT

  19. Spiral CT features of abdomen after whipple's operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Lee, K. Y.; Shin, K. H.; Jung, M. H.; Park, C. M.; Cha, I. H. [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To assess the CT features of postoperative anatomical changes, surgical complications, and patterns of tumor recurrence after Whipple's operation. 42 spiral CT scans of 31 patients who had undergone Whipple's operation were retrospectively reviewed. Postoperative diagnoses were distal CBD cancer in 13 patients, cancer of the ampulla of Vater in ten, cancer of the head of the pancreas in seven, and microcystic cystadenocarcinoma of the pancreas in one. Time intervals between surgery and CT ranged from 1 week to 5 years. CT features of postoperative anastomotic changes, surgical complications, and patterns of tumor recurrence were analyzed. Gastro- or duodeno-jejunal anastomosis was seen in 32 CT scans(74%), pancreaticojejunostomy in 27(64%), and choledochojejunostomy in 24(57%). Pneumobilia was seen in ten patients(34%). Abnormal fluid collections in the peripancreatic and perihepatic space were demonstrated in two patients who underwent CT scans within 3 weeks after operation. Other complications included wound abscess(n=2), and portal vein occlusion(n=1). The most common site of metastasis was the lymph node(n=8)(retroperitoneal:n=5; mesentery root:n=4; and celiac:n=2), followed by the liver(n=6), peritoneum(n=3), adrenal gland(n=2), and afferent loop(n=1). In three cases, there was local recurrence in the pancreatic bed. To reduce possible diagnostic errors during CT interpretation, a Knowledge of normal postoperative anatomy, common complications, and patterns of disease recurrence following Whipple's operation is important.

  20. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... The purpose of the study is to evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma with multi-slice spiral computed tomography (CT) by using double-arterial phase and portal venous phase enhanced scanning. Ninety-four (94) patients with hepatocellular ...

  1. Cranial nerves - spectrum of inflammatory and tumorous changes; Hirnnerven - Spektrum entzuendlicher und tumoroeser Veraenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, S.F.; Kasprian, G.; Nemec, U.; Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Universitaet Wien, Klinische Abteilung fuer Neuroradiologie und muskuloskelettale Radiologie, Wien (Austria)

    2009-07-15

    Inflammatory processes as well as primary and secondary tumorous changes may involve cranial nerves causing neurological deficits. In addition to neurologists, ENT physicians, ophthalmologists and maxillofacial surgeons, radiologists play an important role in the investigation of patients with cranial nerve symptoms. Multidetector computed tomography (MDCT) and particularly magnetic resonance imaging (MRI) allow the depiction of the cranial nerve anatomy and pathological neural changes. This article briefly describes the imaging techniques in MDCT and MRI and is dedicated to the radiological presentation of inflammatory and tumorous cranial nerve pathologies. (orig.) [German] Entzuendliche Prozesse sowie primaere und sekundaere tumoroese Veraenderungen koennen Hirnnerven mitbeteiligen und so zu neurologischen Defiziten fuehren. Neben dem Neurologen, HNO-Arzt, Augenarzt und Kiefer-Gesichts-Chirurgen kommt dem Radiologen eine besondere Bedeutung bei der Abklaerung von Patienten mit Hirnnervensymptomatik zu. Die Multidetektorcomputertomographie (MDCT) und insbesondere die Magnetresonanztomographie (MRT) ermoeglichen die Darstellung der Hirnnervenanatomie sowie der nervalen pathologischen Veraenderungen. Der vorliegende Artikel beschreibt kurz gefasst die bildgebenden Techniken von MDCT und MRT und widmet sich der radiologischen Bildgebung entzuendlicher und tumoroeser Hirnnervenveraenderungen. (orig.)

  2. Creutzfeldt-Jakob disease: the value of MRI; Creutzfeldt-Jakob-Krankheit: Stellenwert der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H.; Tschampa, H.J.; Keller, E.; Schild, H.H. [Radiologische Klinik, Neuroradiologie, Rheinische Friedrich-Wilhelms-Univ. Bonn (Germany); Paus, S. [Neurologische Klinik, Rheinische Friedrich-Wilhelms-Univ. Bonn (Germany)

    2001-06-01

    To define the role of MRI in the diagnosis of Creutzfeldt-Jakob disease (CJD). Methods: 14 patients with suspected CJD were studied within 3 years. MRI findings were correlated with WHO established diagnostic criteria (clinical findings, EEG, CSF with 14-3-3 protein assay). Results: 12 patients had CJD. One patient each suffered from Hashimoto's encephalitis and ALS dementia complex, respectively. Nine of 12 CJD patients had increased signal intensity of the striatum (n = 8), pulvinar thalami (n = 5) and/or cerebellar and cerebral cortex (n = 3), respectively. Signal intensity was most pronounced on FLAIR sequences; six patients were studied with diffusion-weighted MRI and showed impaired diffusion in these areas. Both patients without CJD did not show the abovementioned signal changes (sensitivity 75%, specificity and positive predictive value 100%, respectively). Conclusion: If patients with suspected CJD are studied with FLAIR and diffusion-weighted sequences, this disorder can reliably be proven or ruled out. Typical MRI findings narrow down the differential diagnosis and should be included in the WHO diagnostic criteria. (orig.) [German] Bestimmung des Stellenwerts der MRT in der Diagnostik der Creutzfeldt-Jakob-Krankheit (CJK). Methoden: Analyse der MRTs von 14 innerhalb von drei Jahren mit Verdacht auf CJK zugewiesenen Patienten. Korrelation der MRTs mit den entsprechend den WHO-Diagnosekriterien etablierten Untersuchungsverfahren (Klinik, EEG, Liquor mit 14-3-3 Protein-Nachweis). Ergebnisse: 12 Patienten hatten eine CJK, jeweils ein Patient hatte eine Hashimoto-Enzephalitis bzw. einen ALS-Demenz-Komplex. Bei 9 der 12 CJK-Patienten fanden sich beidseits Signalerhoehungen des Striatum (n = 8), des Pulvinar thalami (n = 5) und/oder des Kleinhirn- bzw. Grosshirnkortex (n = 3). Die Signalerhoehungen waren am deutlichsten auf FLAIR-Aufnahmen erkennbar; 6 mit diffusionsgewichteter MRT untersuchte Patienten wiesen eine eingeschraenkte Diffusion dieser Areale

  3. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  4. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.; Tylen, U.; Aspelin, P.

    2002-01-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  5. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Department of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Department of Radiology, Danderyds Hospital, Danderyd (Sweden); Tylen, U. [Deparment of Radiology, Sahlgrenska University Hospital, Gothenberg (Sweden); Aspelin, P. [Department of Radiology, Huddinge University Hospital, Huddinge (Sweden)

    2002-05-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  6. Preliminary application of 320-detector spiral CT with ECG editing for assessing coronary artery in-stent restenosis

    International Nuclear Information System (INIS)

    Li Zhiming; Tan Lilian; Li Shuxin; Fu Xi; He Weihong; Liu Ke; Huang Yong; Yu Lin

    2011-01-01

    Objective: To determine the value of 320-detector spiral CT with retrospective ECG gating and editing software for detecting coronary artery in-stent restenosis. Methods: CT scans of 14 patients with coronary artery stnets were retrospectively analyzed. The examinations were performed using a 320-detector spiral CT scanner and retrospective ECG gating combined with ECG editing software. The image quality of reconstructed coronary artery in-stents was compared before and after the editing of synchronously recorded ECG. The paired-sample t test was used for statistical analysis. Results: Before ECG editing, arrhythmia and in-stent artifact resulted in image blurring, missing arterial segments, significant stepladder artifacts or non-visualization of the interior of stents. Of 14 cases before ECG editing, in-stent restenosis was detected in 10 and patency in 3. The coronary artery stent and distal bifurcation were delineated in one patient. After ECG editing, the image quality of coronary artery stents was improved with detection of in-stent restenosis (4 cases) including the one case that not evaluable before ECG editing. The average image quality score before ECG editing (2.14±0.86) was significantly (P<0.001) lower than that after ECG editing (3.07±0.73). Conclusion: Retrospective ECG gating combined with ECG editing of 320-detector spiral CT can reduce the artifacts produced by arrhythmia or in-stent swings and improve the imaging quality of coronary artery stents. (authors)

  7. A study of parameters in spiral CT volumetry using balloon phantoms

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Han, Joon Koo

    2001-01-01

    To evaluate the effects of threshold values, reconstruction interval, slice thickness and table speed on the spiral CT volumetry. Two phantoms made of a balloon and diluted contrast media underwent spiral CT scanning with section thicknesses of 5, 7 and 10 mm and table speeds of 5, 8 and 10 mm with scans of 5 mm section thickness, 7, 10, and 14 mm with scans of 7 mm section thickness, and 10, 15, and 20 mm with scans of 10 mm section thickness. The volumetric values of phantom A and B were obtained at varying threshold values and a reconstruction interval of 5 and 10 mm for all scans. Volumes were also determined with the threshold value fixed and a reconstruction interval of 1, 5, 7 and 10 mm, respectively. Three-dimensional display and volumetric measurements were obtained using reconstructed images. The effects of threshold value, reconstruction interval, slice thickness and table speed on volumetry were analyzed. Volumetric values varied according to threshold values. Where a threshold value was low, value increased as pitch increased, but where a the threshold value was high, value decreased as pitch increased. With varying threshold values, measurement errors in CT volumetry were 1.6 to 9.0%. Volume decreased as reconstruction interval increased. Where the table speed/ slice thickness ratio was constant, volume was constant though slice thickness differed. At fixed threshold values, variation in the reconstruction interval was statistically more significant than variation in slice thickness or table speed (p<0.05, Kruskal-Wallis one-way ANOVA). Among serveral spiral scanning and image reconstruction parameters including threshold value, reconstruction interval, slice thickness, and table speed, threshold value most affected the result obtained. At fixed threshold values, the reconstruction interval used had more effect on CT volumetry than other parameters

  8. Quantitative Analyse und Visualisierung der Herzfunktionen

    Science.gov (United States)

    Sauer, Anne; Schwarz, Tobias; Engel, Nicole; Seitel, Mathias; Kenngott, Hannes; Mohrhardt, Carsten; Loßnitzer, Dirk; Giannitsis, Evangelos; Katus, Hugo A.; Meinzer, Hans-Peter

    Die computergestützte bildbasierte Analyse der Herzfunktionen ist mittlerweile Standard in der Kardiologie. Die verfügbaren Produkte erfordern meist ein hohes Maß an Benutzerinteraktion und somit einen erhöhten Zeitaufwand. In dieser Arbeit wird ein Ansatz vorgestellt, der dem Kardiologen eine größtenteils automatische Analyse der Herzfunktionen mittels MRT-Bilddaten ermöglicht und damit Zeitersparnis schafft. Hierbei werden alle relevanten herzphysiologsichen Parameter berechnet und mithilfe von Diagrammen und Graphen visualisiert. Diese Berechnungen werden evaluiert, indem die ermittelten Werte mit manuell vermessenen verglichen werden. Der hierbei berechnete mittlere Fehler liegt mit 2,85 mm für die Wanddicke und 1,61 mm für die Wanddickenzunahme immer noch im Bereich einer Pixelgrösse der verwendeten Bilder.

  9. Kontinuierliche Wanddickenbestimmung und Visualisierung des linken Herzventrikels

    Science.gov (United States)

    Dornheim, Lars; Hahn, Peter; Oeltze, Steffen; Preim, Bernhard; Tönnies, Klaus D.

    Zur Bestimmung von Defekten in der Herztätigkeit kann die Veränderung der Wanddicke des linken Ventrikels in zeitlichen MRTAufnahmesequenzen gemessen werden. Derzeit werden für diese Bestimmung im allgemeinen nur die aufwändig manuell erstellte Segmentierungen der Endsystole und Enddiastole benutzt. Wir stellen ein bis auf die Startpunktinitialisierung automatisches Verfahren zur Bestimmung der Wanddicke des linken Ventrikels und ihrer Veränderung vor, das auf einer vollständigen Segmentierung der Herzwand in allen Zeitschritten durch ein dynamisches dreidimensionales Formmodell (Stabiles Feder-Masse-Modell) basiert. Dieses Modell nutzt bei der Segmentierung neben der Grauwertinformation eines Zeitschrittes auch die Segmentierungen der anderen Zeitschritte und ist so aufgebaut, dass die Wanddicken direkt gemessen und visualisiert werden können. Auf diese Weise werden die lokalen Wanddickenextrema über den gesamten Aufnahmezeitraum detektiert, auch wenn sie nicht in die Endsystole bzw. -diastole fallen. Das Verfahren wurde auf sechs 4D-Kardio-MRT-Datensätzen evaluiert und stellte sich als sehr robust bzgl. der einzig nötigen Interaktion heraus.

  10. Selected clinically established and scientific techniques of diffusion-weighted MRI. In the context of imaging in oncology; Ausgewaehlte klinisch etablierte und wissenschaftliche Techniken der diffusionsgewichteten MRT. Im Kontext der onkologischen Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, M.T.; Bickelhaupt, S.; Ziener, C.; Mosebach, J.; Schlemmer, H.P. [Deutsches Krebsforschungszentrum, Abteilung fuer Radiologie, Heidelberg (Germany); Meier-Hein, K. [Deutsches Krebsforschungszentrum, Abteilung fuer medizinische Informatik, Heidelberg (Germany); Radtke, J.P. [Deutsches Krebsforschungszentrum, Abteilung fuer Radiologie, Heidelberg (Germany); Universitaetsklinik Heidelberg, Abteilung fuer Urologie, Heidelberg (Germany); Kuder, T.A.; Laun, F.B. [Deutsches Krebsforschungszentrum, Abteilung fuer Medizinische Physik in der Radiologie, Heidelberg (Germany)

    2016-02-15

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique that was established in the clinical routine primarily for the detection of brain ischemia. In the past 15 years its clinical use has been extended to oncological radiology, as tumor and metastases can be depicted in DWI due to their hypercellular nature. The basis of DWI is the Stejskal-Tanner experiment. The diffusion properties of tissue can be visualized after acquisition of at least two diffusion-weighted series using echo planar imaging and a specific sequence of gradient pulses. The use of DWI in prostate MRI was reported to be one of the first established applications that found its way into internationally recognized clinical guidelines of the European Society of Urological Radiology (ESUR) and the prostate imaging reporting and data system (PI-RADS) scale. Due to recently reported high specificity and negative predictive values of 94 % and 92 %, respectively, its regular use for breast MRI is expected in the near future. Furthermore, DWI can also reliably be used for whole-body imaging in patients with multiple myeloma or for measuring the extent of bone metastases. New techniques in DWI, such as intravoxel incoherent motion imaging, diffusion kurtosis imaging and histogram-based analyses represent promising approaches to achieve a more quantitative evaluation for tumor detection and therapy response. (orig.) [German] Die diffusionsgewichtete Bildgebung (''diffusion-weighted imaging'', DWI), ein Verfahren aus der Magnetresonanztomographie (MRT), wurde in der klinischen Routine primaer fuer die Detektion von Schlaganfaellen etabliert. Der Einsatz dieser Methode hat in den letzten 15 Jahren auch fuer die onkologische Diagnostik stark zugenommen, da Tumoren und Metastasen aufgrund ihrer hochzellulaeren Zusammensetzung in der DWI sehr gut sichtbar gemacht werden koennen. Basis der diffusionsgewichteten Bildgebung ist das Experiment nach Stejskal-Tanner. Hier

  11. Chronic pulmonary embolism - radiological imaging and differential diagnosis; Chronische Lungenembolie - Radiologische Bildmorphologie und Differenzialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Coppenrath, E.; Herzog, P.; Attenberger, U.; Reiser, M. [Klinikum Innenstadt der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2007-08-15

    In chronic pulmonary embolism branches of the pulmonary arterial tree remain partially or totally occluded. This may lead to pulmonary hypertension with the development of right ventricular hypertrophy as well as structural changes of pulmonary arteries. Imaging of chronic pulmonary embolism should prove vessel occlusions (pulmonary angiography, MSCT, MRI) and reduction of regional lung perfusion (lung scanning, MSCT, MRI). According to current guidelines ventilation-perfusion lung scanning and pulmonary angiography are still recommended as the methods of choice. MSCT and MRI provide technical alternatives which are helpful in differential diagnosis versus other types of pulmonary hypertension. In spite of medical and surgical measures (in rare cases pulmonary thromboendarterectomy) the prognosis of chronic pulmonary embolism remains unfavourable. (orig.) [German] Bei der chronischen Lungenembolie sind Abschnitte der arteriellen Lungenstrombahn dauerhaft verschlossen. Dies kann zu einer Erhoehung des pulmonal-arteriellen Drucks mit den Folgen einer Rechtsherzbelastung und strukturellen Veraenderungen der Pulmonalarterien fuehren. Bildmorphologisch nachzuweisen sind Gefaessverschluesse (Pulmonalisangiographie, MSCT, MRT) und die Minderperfusion des Lungenparenchyms (Szintigraphie, MSCT, MRT). Nach den bisherigen Empfehlungen gelten fuer die Diagnostik der chronischen Lungenembolie die Lungenszintigraphie (Ventilation/Perfusion) und die Pulmonalisangiographie als Methoden der ersten Wahl. Die MSCT und MRT (Angiographie/Perfusion) stellen technische Alternativen dar. Differenzialdiagnostisch sind andere Formen der pulmonalen Hypertonie abzugrenzen. Trotz medikamentoeser und chirurgischer Therapiemassnahmen (z. B. pulmonale Thrombendarterektomie) bleibt die Prognose der chronischen Lungenembolie unguenstig. (orig.)

  12. Physiological and technical limitations of functional magnetic resonance imaging (fMRI) - consequences for clinical use; Physiologische und technische Grenzen der funktionellen Magnetresonanztomographie und die damit verbundenen Konsequenzen fuer die klinische Anwendung

    Energy Technology Data Exchange (ETDEWEB)

    Wuestenberg, T. [Neurologische Klinik der Charite, Humboldt-Universitaet Berlin (Germany); Neurologische Klinik der Charite, Humboldt-Universitaet Berlin, Schumannstrasse 20/21, 10117, Berlin (Germany); Jordan, K. [Institut fuer Psychologie II, Otto-von-Guericke-Universitaet Magdeburg (Germany); Giesel, F.L. [Abteilung fuer onkologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum Heidelberg (Germany); Villringer, A. [Neurologische Klinik der Charite, Humboldt-Universitaet Berlin (Germany)

    2003-07-01

    Functional magnetic resonance imaging (fMRI) is the most common noninvasive technique in functional neuroanatomy. The capabilities and limitations of the method will be discussed based on a short review of the current knowledge about the neurovascular relationship. The focus of this article is on current methodical and technical problems regarding fMRI-based detection and localization of neuronal activity. Main error sources and their influence on the reliability and validity of fMRI-methods are presented. Appropriate solution strategies will be proposed and evaluated. Finally, the clinical relevance of MR-based diagnostic methods are discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) ist eines der wichtigsten Verfahren der funktionellen Neuroanatomie. Aufbauend auf einer kurzen Darstellung des aktuellen Wissensstands bzgl. des Zusammenhangs zwischen lokaler neuronaler Aktivitaet und haemodynamischer Reaktion werden ausgewaehlte Moeglichkeiten und Grenzen des Verfahrens fuer die klinische Anwendung diskutiert. Der Schwerpunkt liegt dabei auf der Darstellung der derzeitigen methodischen und technischen Einschraenkungen hinsichtlich einer fMRT-basierten Detektion und Lokalisierung neuronaler Aktivitaet. Es werden die Hauptfehlerquellen und ihre Auswirkungen auf die Reliabilitaet und Validitaet des Verfahrens erlaeutert und aktuelle Loesungsansaetze diskutiert. Abschliessend erfolgt eine Bewertung der aktuellen klinischen Relevanz funktioneller MR-Diagnosemethoden. (orig.)

  13. Abdominal spiral CT in children: which radiation exposure is required?

    Energy Technology Data Exchange (ETDEWEB)

    Wormanns, D.; Diederich, S.; Lenzen, H.; Ludwig, K.; Papke, Karsten; Hagedorn, Claudia; Heindel, Walter [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Lange, P.; Link, T.M. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Dept. of Radiology, Technical Univ. Muenchen (Germany)

    2001-11-01

    We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: group A with reduced radiation exposure (tube current 50 mA, CT dose index CTDI{sub FDA} {<=}0.83 mGy) and group B with standard radiation exposure (tube current {>=}100 mA, CTDI{sub FDA} {>=}1.66 mGy). Image quality was assessed using a four-part scale ('excellent', 'good', 'sufficient', 'poor') on visual image impression and visibility of 32 anatomical details. Five experienced radiologists read the CT scans independently who were blinded to the examination parameters. Differences in ranked data were evaluated with Wilcoxon's rank sum test. No difference between groups A and B was observed in visual image impression. Detail visibility was significantly lower in group A, but the differences were limited to right upper quadrant structures (portal vein, common bile duct, pancreatic head, adrenals) and to arterial branches. Significant differences in visibility rated as 'poor' were only found for the hepatic, splenic and renal arteries; all other structures showed no difference between groups A and B. A protocol with reduced radiation exposure (50 mA, CTDI{sub FDA} {<=}0.83 mGy) allowed the demonstration of most anatomic structures in abdominal spiral CT in young children. For the precise demonstration of small details (e.g. structures of the right upper quadrant), a protocol with standard radiation exposure ({>=}100 mAs) was superior. (orig.)

  14. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  15. MRT of the locomotor system. 4. rev. and enl. ed.; MRT des Bewegungsapparats

    Energy Technology Data Exchange (ETDEWEB)

    Vahlensieck, Martin [Praxisnetz Radiologie und Nuklearmedizin Bonn Bad Godesberg - RheinSieg, Bonn (Germany); Reiser, Maximilian (ed.) [Klinikum Grosshadern, Muenchen (Germany). Inst. fuer Klinische Radiologie

    2015-02-01

    The book on MRT of the locomotor system covers the following topics: relevant NMT imaging techniques, spinal cord, shoulder, elbows, wrist and fingers, hip region, knee, lower leg - ankle - foot, temporomandibular joint, skeletal muscles, bone marrow, bone and soft tissue tumors, osteoporosis, sacroiliac joint, jaw and periodontium.

  16. Pancreatic neuroendocrine neoplasms; Neuroendokrine Neoplasien des Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, K.; Lauenstein, T.C. [Universitaetsklinikum Essen, Institut fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Essen (Germany); Sabet, A.; Poeppel, T.D. [Universitaetsklinikum Essen, Klinik fuer Nuklearmedizin, Essen (Germany); Lahner, H. [Universitaetsklinikum Essen, Klinik fuer Endokrinologie und Stoffwechselerkrankungen, Essen (Germany)

    2016-04-15

    Pancreatic neuroendocrine neoplasms (NEN) account for 1-2 % of all pancreatic neoplasms and represent a rare differential diagnosis. While some pancreatic NEN are hormonally active and exhibit endocrine activity associated with characteristic symptoms, the majority are hormonally inactive. Imaging techniques such as ultrasound, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) or as combined PET/CT play a crucial role in the initial diagnosis, therapy planning and control. Endoscopic ultrasound (EUS) and multiphase CT represent the reference methods for localization of the primary pancreatic tumor. Particularly in the evaluation of small liver lesions MRI is the method of choice. Somatostatin receptor scintigraphy and somatostatin receptor PET/CT are of particular value for whole body staging and special aspects of further therapy planning. (orig.) [German] Neuroendokrine Neoplasien (NEN) des Pankreas stellen mit einem Anteil von 1-2 % aller pankreatischen Tumoren eine seltene Differenzialdiagnose dar. Ein Teil der Tumoren ist hormonell aktiv und faellt klinisch durch charakteristische Symptome auf, wohingegen der ueberwiegende Anteil hormonell inaktiv ist. Bildgebende Verfahren wie Sonographie, Computertomographie (CT), Magnetresonanztomographie (MRT) und nicht zuletzt Positronenemissionstomographie (PET oder kombiniert als PET/CT) spielen eine zentrale Rolle fuer Erstdiagnose, Therapieplanung und -kontrolle. Die Endosonographie und die multiphasische CT stellen die Referenzmethoden zur Lokalisation des Primaertumors dar. Fuer die Differenzierung insbesondere kleiner Leberlaesionen bietet die MRT die hoechste Aussagekraft. Fuer das Ganzkoerperstaging und bestimmte Aspekte der Therapieplanung lassen sich die Somatostatinrezeptorszintigraphie und v. a. die Somatostatinrezeptor-PET/CT heranziehen. (orig.)

  17. Classification of fractures of the distal r[ius - Comparative evaluation of spiral CT images and X-rays

    International Nuclear Information System (INIS)

    Roehnert, W.; Nitzsche, H.; Franck, W.M.; Amlang, M.

    1998-01-01

    Within the framework of a prospective study 35 patients with fractures of the distal r[ius safely diagnosed to require surgery have been [ditionally scanned by spiral CT. For more exact diagnostic evaluation of the joint surfaces and the fractures, multiplane reconstructions have been m[e to enhance the information obtained from the primary, axial tomographic images. Two experts independently performed classification on the basis of the X-rays and the CT scans, applying the AO scheme and the method of Frykman. Classifications according to the AO scheme were found to agree for only 28.6 % of the patients, which means that 57.1 % of the fractures shown by the X-rays were more or less underassessed. Classification according to Frykman's method revealed fewer deviations and agreement in 51.4 % of the cases. Biplanar r[iography continues to be considered as the standard method for examination of distal r[ius fractures, but it is recommended to perform spiral CT scans for evaluation of more complex distal r[ius fractures because these may require different therapies according to fracture types. (orig./CB) [de

  18. Spiral CT in kidney: assumption of renal function by objective evaluation of renal cortical enhancement

    International Nuclear Information System (INIS)

    Choi, Bo Yoon; Lee, Jong Seok; Lee, Joon Woo; Myung, Jae Sung; Sim, Jung Suk; Seong, Chang Kyu; Kim, Seung Hyup; Choi, Guk Myeong; Chi, Seong Whi

    2000-01-01

    To correlate the degree of renal cortical enhancement, objectively evaluated by means of spiral CT with the serum level of creatinine, and to determine the extent to which this degree of enhancement may be used to detect renal parenchymal disease. Eighty patients (M:F = 50:30; age + 25-19, (mean 53) years) with available serum level of creatinine who underwent spiral CT between September and October 1999 were included in this study. In fifty patients the findings suggested hepatic or biliary diseases such as hepatoma, biliary cancer, or stone, while in thirty, renal diseases such as cyst, hematoma, or stone appeared to be present. Spiral CT imaging of the cortical phase was obtained at 30-40 seconds after the injection of 120 ml of non-ionic media at a rate of 3 ml/sec. The degree of renal cortical enhancement was calculated by dividing the CT attenuation number of renal cortex at the level of the renal hilum by the CT attenuation number of aorta at the same level. The degree of renal cortical enhancement was compared with the serum level of creatinine, and the degree of renal cortical enhancement in renal parenchymal disease with that of the normal group. Among eighty patients there were five with renal parenchymal disease and 75 with normal renal function. The ratio of the CT attenuation number of renal cortex to that of aorta at the level of the renal hilum ranged between 0.49 and 0.99 (mean, 0.79; standard deviation, 0.15). while the serum level of creatinine ranged between 0.6 and 3.2 mg/dl. There was significant correlation (coefficient of -0.346) and a statistically significant probability of 0.002 between the ratio of the CT attenuation numbers and the serum level of creatinine. There was a significant difference (statistically significant probability of less than 0.01) between those with renal parenchymal disease and the normal group. The use of spiral CT to measure the degree of renal cortical enhancement provides not only an effective index for

  19. Spiral CT and optimization of the modalities of the iodinated intravenous contrast material: Experimental studies in human pathology

    International Nuclear Information System (INIS)

    Bonaldi, V.

    1998-01-01

    Spiral (or helical) CT represents the most recent improvement in the field of computed assisted tomography (CAT scan). The capabilities of this new imaging modality are much superior to these of conventional CT scanning; then result from the rapid acquisition and from the volumetric nature of the derived data set. The short time of data acquisition had made mandatory the revision of protocols for intravenous administration of iodinated contrast material. By the means of several studies, carried out on pathologic and healthy patients, we have attempted to improve knowledge in factors influencing CT attenuation values after injection of contrast material, in the aim of improving contrast administration performed during spiral CT scanning. Anatomical landmarks that we have studied till now have been liver, the pancreas, the kidney and the cervical spine. In addition, a paired based methodology has been used. The volumetric set of data derived from spiral CT scanning leads to optimal post-processing tasks, the most interesting being related to cine-display and multiplanar reformatting; both modalities have been evaluated, about the pancreas and the musculo-skeletal system respectively. Conversely, this new modality, as for other imaging modalities, is responsible for additional costs derived from restless increase in the number of images to be dealt with and from the occurrence of new tasks (in post-processing particularly). The place of spiral CT in diagnostic strategies among other modern imaging modalities should be assessed, especially with respect to Magnetic Resonance Imaging (MRI). (author)

  20. Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies.

    Science.gov (United States)

    Applegate, K E; Dardinger, J T; Lieber, M L; Herts, B R; Davros, W J; Obuchowski, N A; Maneker, A

    2001-12-01

    Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized.

  1. Establishment of an orthotopic lung cancer model in nude mice and its evaluation by spiral CT.

    Science.gov (United States)

    Liu, Xiang; Liu, Jun; Guan, Yubao; Li, Huiling; Huang, Liyan; Tang, Hailing; He, Jianxing

    2012-04-01

    To establish a simple and highly efficient orthotopic animal model of lung cancer cell line A549 and evaluate the growth pattern of intrathoracic tumors by spiral CT. A549 cells (5×10(6) mL(-1)) were suspended and inoculated into the right lung of BALB/c nude mice via intrathoracic injection. Nude mice were scanned three times each week by spiral CT after inoculation of lung cancer cell line A549. The survival time and body weight of nude mice as well as tumor invasion and metastasis were examined. Tissue was collected for subsequent histological assay after autopsia of mice. The tumor-forming rate of the orthotopic lung cancer model was 90%. The median survival time was 30.7 (range, 20-41) days. The incidence of tumor metastasis was 100%. The mean tumor diameter and the average CT value gradually increased in a time-dependent manner. The method of establishing the orthotopic lung cancer model through transplanting A549 cells into the lung of nude mice is simple and highly successful. Spiral CT can be used to evaluate intrathoracic tumor growth in nude mice vividly and dynamically.

  2. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  3. Gastroenteropancreatic endocrine tumors; Gastroenteropankreatische endokrine Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Schmid-Tannwald, C.; Schmid-Tannwald, C.M.; Reiser, M.F.; Berger, F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2014-10-15

    % aller gastrointestinalen Tumoren ausmacht. Fuer die Lokalisation des Primaertumors als auch fuer das Staging endokriner Tumoren spielen neben der Ultraschalldiagnostik die Computertomographie (CT), die Magnetresonanztomographie (MRT) und die Positronenemissionstomographie-Computertomographie (PET-CT) eine entscheidende Rolle. Neben dem Primaerstaging lassen sich mithilfe der PET-CT mit Somatostatinanaloga auch die Indikation fuer eine Radionuklidtherapie stellen und der Therapieverlauf dokumentieren. Das CT-Enteroklysma erreicht nach der Literatur bei Duenndarmtumoren bis 3 cm eine Sensitivitaet von 84,7 %, eine Spezifitaet von 96,9 %; mit der Magnetresonanzenterographie (MRE) kann ein neuroendokriner Tumor (NET) des Duenndarms in 93,3 % der Faelle lokalisiert werden. Laut Literatur ist die MRT bei der Detektion pankreatischer NET mit einer Sensitivitaet zwischen 74 und 100 % der CT ueberlegen. Die PET-CT ermoeglicht die Detektion sehr kleiner Primaertumoren und gilt als sensitivste Methode zur Lokalisationsdiagnostik. Bei der Detektion von Lebermetastasen ist die MRT der CT und der PET-CT ueberlegen. Aufgabe der bildgebenden Diagnostik ist es, neben der Lokalisation des Primaertumors und dem Staging, Therapien zu planen und ein Therapieansprechen zu dokumentieren. Die Wahl der verschiedenen bildgebenden Verfahren hierfuer ist abhaengig von der Lokalisation des Primaertumors. Da gastroenteropankreatische neuroendokrine Tumoren (GEP-NET) ueberwiegend hypervaskularisiert sind, ist eine biphasische Untersuchungstechnik nach Kontrastmittelgabe in arterieller und venoeser Phase fuer die Abklaerung von Primaertumoren und Metastasen sowohl in der CT wie in der MRT obligat. Fuer das Ganzkoerperstaging kommen vorrangig CT und PET-CT zum Einsatz. (orig.)

  4. The diagnostic value of multi-slice spiral CT virtual bronchoscopy in tracheal and bronchial disease

    International Nuclear Information System (INIS)

    Han Ying; Ma Daqing

    2006-01-01

    Objective: To assess the diagnostic value of multi-slice spiral CT virtual bronchoscopy (CTVB) in tracheal and bronchial disease. Methods: Forty-two patients including central lung cancer (n=35), endobronchial tuberculosis (n=3), intrabronchial benign tumor (n=3), and intrabronchial foreign body (n=1) were examined by using multi-slice spiral CT examinations. All the final diagnosis were proved by pathology except 1 patient with endoluminal foreign body was proved by clinic. All patients were scanned on GE Lightspeed 99 scanner, using 10 mm collimation, pitch of 1.35, and reconstructed at 1 mm intervals and 1.25 mm thickness. The chest images of transverse CT and virtual bronchoscopy were viewed by two separate radiologists who were familiar with the tracheal and bronchial anatomy. Results: Among the 42 patients, the tumor of trachea and bronchial lumen appeared as masses in 22 of 35 patients with central lung cancer and bronchial stenosis was found in 13 of 35 patients with central lung cancer, and bronchial wall thickening was revealed on transverse CT in all 35 cases. 3 patients of endobronchial tuberculosis showed bronchial lumen narrowing on CTVB, the bronchial wall thickening was revealed on transverse CT, and the length of the wall thickening was long. 3 patients with intrabronchial benign tumor showed nodules in trachea and bronchial lumen on CTVB, and without wall thickening on transverse CT. CTVB could detect the occlusion of bronchial lumen in 1 patient with intrabronchial foreign body and CTVB was able to visualize the areas beyond stenosis, and the bronchial wall was without thickening on transverse CT. Conclusion: Multi- slice spiral CTVB could reflect the morphology of tracheal and bronchial disease. Combined with transverse CT, it could provide diagnostic reference value for bronchial disease. (authors)

  5. Neuroendocrine tumors of the abdomen; Neuroendokrine Tumoren des Abdomens

    Energy Technology Data Exchange (ETDEWEB)

    Juchems, M. [Klinikum Konstanz, Diagnostische und Interventionelle Radiologie, Konstanz (Germany)

    2018-01-15

    Gastroenteropancreatic neuroendocrine neoplasia (GEP-NEN) are a heterogeneous group of complex tumors, which is often difficult to classify due to heterogeneity and varying locations. Ultrasound, computed tomography (CT), magnetic resonance imaging (MRI) and positron-emission tomography computed tomography (PET/CT) are available for the localization of NEN as well as for the staging. In particular, nuclear medical examination methods with somatostatin analogues are of great importance since radioactively labeled receptor ligands make tumors visible with high sensitivity. CT and MRT have high detection rates for GEP-NEN and have been further improved by developments such as diffusion weighted imaging. The nuclear medical methods, however, are superior in detection, especially in gastrointestinal NEN It is important for the radiologist to become acquainted with the NEN as they can occur ubiquitously in the abdomen and should be identified as such. Since GEP-NEN are predominantly hypervascularized, a biphasic examination technique is obligatory for contrast-enhanced cross-sectional imaging. PET/CT with somatostatin analogs should be used for further diagnosis. (orig.) [German] Gastroenteropankreatische neuroendokrine Neoplasien (GEP-NEN) sind eine heterogene Gruppe komplexer Tumoren, deren Einteilung aufgrund der Heterogenitaet und unterschiedlichen Lokalisation haeufig schwerfaellt. Fuer die Lokalisation der NEN sowie zur Ausbreitungsdiagnostik und Metastasensuche stehen Ultraschalldiagnostik, Computertomographie (CT), Magnetresonanztomographie (MRT) und die Positronenemissionstomographie-Computertomographie (PET-CT) zur Verfuegung. Insbesondere nuklearmedizinische Untersuchungsmethoden mit Somatostatinanaloga sind von hoher Wertigkeit, da sie ueber radioaktiv markierte Rezeptoliganden Tumoren mit hoher Sensitivitaet sichtbar machen. CT und MRT haben hohe Detektionsraten bei den GEP-NEN und konnten durch Weiterentwicklungen, wie Diffusionsbildgebung, weiter

  6. New aspects of MRI for diagnostics of large vessel vasculitis and primary angiitis of the central nervous system; Neue Aspekte der MRT-Bildgebung zur Diagnostik der Grossgefaessvaskulitiden sowie der primaeren Angiitis des zentralen Nervensystems

    Energy Technology Data Exchange (ETDEWEB)

    Saam, T.; Habs, M.; Cyran, C.C.; Grimm, J.; Reiser, M.F.; Nikolaou, K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Pfefferkorn, T. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Neurologie, Muenchen (Germany); Schueller, U. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Zentrum fuer Neuropathologie, Muenchen (Germany)

    2010-10-15

    der Gefaesswand zu, allerdings sind nur ausgewaehlte extrakranielle Gefaesse mit ausreichender Aufloesung schallbar. Da den Vaskulitiden primaer Veraenderungen der Gefaesswand zugrunde liegen und die gefundenen luminalen Veraenderungen in der Regel unspezifisch sind und auch bei anderen Erkrankungen auftreten koennen, sind die gebraeuchlichen Verfahren in ihrer Aussagekraft oft limitiert. Mit der hochaufgeloesten MRT der zervikalen und intrakraniellen Gefaesse steht eine viel versprechende neue Methode zur Verfuegung, die die entzuendlich veraenderte Gefaesswand nichtinvasiv und ohne Verwendung ionisierender Strahlen im Detail zu visualisieren vermag. In diesem Beitrag sollen die verwendeten Untersuchungsprotokolle vorgestellt und klinische Bildbeispiele gezeigt werden. Dabei sollen insbesondere die Grossgefaessvaskulitiden und die Vaskulitiden des ZNS behandelt werden. Zudem werden die haeufigsten radiologischen Differenzialdiagnosen demonstriert und andere bildgebende Methoden, wie PET/CT und Ultraschall, die ebenfalls zur Diagnostik der Vaskulitiden eingesetzt werden, diskutiert. (orig.)

  7. Hydro-MRI for abdominal diagnostics in children; Hydro-MRT in der Darmdiagnostik bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Kern, A.; Schunk, K.; Oberholzer, K.; Thelen, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Kessler, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Kinderchirurgie

    2001-11-01

    A clinical evaluation of hydro-MRI as an alternative method to barium studies in children with abdominal pain of unknown origin is presented. Patients and Methods: 20 children with abdominal pain of unknown origin aged from 9 - 16 years were examined after oral bowel opacification using 1000 ml of 2.5% mannitol solution with a 1.0T MRI system. The investigation was done in 2 planes (coronal and axial) under breath-hold conditions. Imaging procedures included various sequences (T2W HASTE + FS, contrast-enhanced T1W FLASH FS). Suspicious findings in bowel segments and extra-intestinal changes were assessed. Results: In 21/24 examinations the small bowel was completely visualized, in 15/24 cases colon segments were identified. An accurate assessment of the terminal ileum was not possible in 3/24 procedures. Breathing artefacts occurred in 3/24 examinations. Signs of Crohn's disease were found in 4 examinations, inflammatory changes of the ileum were detected in 3 cases. Inflammation of the colon was demonstrated in 2 children. Furthermore, pathological findings included constipation in one child and inflammation of the ileo-colic and mesenterial lymph nodes were found in another child. Extra-intestinal changes in 3 children were caused by ovarian cysts, and in one case by pleural effusion. In 4 examinations we detected ascites in the absence of other pathological findings. In 5 children there was no pathological correlation in the bowel or extra-intestinal region for the complaints. The children tolerated the hydro-MRI very well. There were no side effects using oral mannitol. (orig.) [German] Ziel: Klinische Evaluation der Hydro-MRT bei Kindern mit unklarer abdomineller Symptomatik als alternative Methode zur fraktionierten Magen-Darm-Passage. Patienten und Methoden: 20 Kinder und Jugendliche im Alter von 9 bis 16 Jahren mit unklaren abdominellen Beschwerden bzw. mit Verdacht auf eine chronisch entzuendliche Darmerkrankung wurden nach einer oralen

  8. Power doppler ultrasound findings of renal infarct after experimental renal artery occlusion: comparison with spiral CT

    International Nuclear Information System (INIS)

    Jung, Seung Eun; Shinn, Kyung Sub; Kim, Hak Hee; Mun, Seok Hwan; Lee, Young Joon; Lee, Bae Young; Choi, Byung Gil; Lee, Jae Mun; Lee, Hee Jeong

    1999-01-01

    To evaluate the efficacy of power Doppler ultrasonography (PDUS) in depicting renal infarction in rabbits during experimental renal segmental arterial occlusion, and to compare the results with those of CT scanning. In 28 rabbits weighing 2.5 4kg, the segmental renal artery was occluded through the left main renal artery by embolization with Ivalon (Nycomed, Paris, France). Power Doppler ultrasonography and spiral CT scanning were performed before and at 2, 5, 8, 15, and 24 hours, and 3 and 7 days after occlusion of the segmental renal artery. The location of infarcted areas and collaterals, as seen on PDUS and CT scans, was evaluated by two radiologists. In all cases, as seen on power Doppler ultrasonography, infarcted areas-when compared with normal parenchyma, clearly demonstrated wedge-shaped perfusion defects in the kidney. The location of the lesion closely corresponded to the location seen during CT scanning. After renal arterial occlusion, transiently congested capsular arteries, which were named 'capsular sign', were seen in 63% of rabbits in the two and five-hour groups. No significant cortical rim sign was demonstrated on power Doppler ultrasonography, though it was noted on spiral CT at 15 and 24 hours, and 3 and 7 days after renal arterial occlusion. Power Doppler ultrasonography was useful for the diagnosis of renal infarction. Congested capsular artery seen in the early stage of renal infarction might be a characteristic finding of this condition, as seen on power Doppler ultrasonography

  9. Risk-benefit analysis and cost-effectiveness analysis of lung cancer screening by spiral CT

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1999-01-01

    Mass screening of lung cancer has been widely performed using indirect chest X-ray method in Japan. However reduction of the mortality for lung cancer is questioned. We have proposed that recently developed spiral CT should be adopted for the screening of lung cancer, since CT has an excellent detectability for small nodule. Lung Cancer Screening CT (LSCT) has been developed by author's group using spiral CT with low dose and light weight in order to make a mobile unit. In this paper risk-benefit analysis and cost-effectiveness analysis are described for the LSCT screening of lung cancer. As a risk, radiation carcinogenesis due to exposure from LSCT are compared with gain of life-expectancy by screening and men of 40 years or more and women of 45 years or more are justified. The cost per person-year is estimated for LSCT screening which is better than that of present method, although total cost is higher. The LSCT screening could be recommended if total cost is affordable. (author)

  10. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  11. Speech recognition: impact on workflow and report availability; Spracherkennung: Auswirkung auf Workflow und Befundverfuegbarkeit

    Energy Technology Data Exchange (ETDEWEB)

    Glaser, C.; Trumm, C.; Nissen-Meyer, S.; Francke, M.; Kuettner, B.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie

    2005-08-01

    Hauptkomponenten eines SES sind das akustische und das Sprachmodell. Merkmale kontinuierlicher SES mit Realtimeerkennung umfassen vorformulierbare Befund(bloeck)e, Standardbefundvorlagen und Sprachkommandos (Navigation im Text, Steuerung von SES und RIS). Sinnvoll fuer eine optimale Nutzung des SES-Potenzials ist die Integration von SES, RIS und PACS. Wichtige Leistungsparameter eines SES sind Befundverfuegbarkeit und Zeiteffizienz des Befundungsprozesses (Erkennungsrate, Editier- und Korrekturaufwand, Wortschatzpflege) fuer den Radiologen. In der Praxis wird die Erkennungsrate ueber die Fehlerrate (Einheit ''Wort'') abgeschaetzt. Fehlerraten liegen zwischen 4 und 28%. Etwa 20% davon sind Wortschatzfehler, die u. U. zu einer falschen Befundinterpretation fuehren koennen. Sie unterstreichen die Notwendigkeit einer sorgfaeltigen Textkorrektur und Wortschatzpflege. Die Einfuehrung eines SES erbringt eine drastische Verbesserung der Befundverfuegbarkeit. Dagegen nimmt der individuelle aerztliche Zeitbedarf bei digitaler Befunderstellung um ca. 20-25% (Projektionsradiographie, CR) bzw. ca. 30% (CT, MRT) zu. Die Entlastung des Schreibbueros (Hintergrunddiktat) haengt von dessen Qualifikation ab. Das Onlinediktat fuehrt zu einer Umverteilung von Arbeitsschritten vom Schreibbuero auf den Befunder. (orig.)

  12. Three phase spiral liver Scanning

    International Nuclear Information System (INIS)

    Kanyanja, T.A.

    2006-01-01

    The ability to perform rapid back-to-back spiral acquisitions is an important recent technical advantage of spiral CT. this allows imaging of the upper abdomen (liver) during peak arterial enhancement (arterial phase) and during peak hepatic parenchymal enhancement (portal venous phase). Breatheld spiral CT has completely replaced dynamic incremental CT for evaluation of the liver. in selected patients with hyper vascular metastasis (hepatoma, neuroendocrine tumors, renal cell carcinoma, etc.) a biphasic examination is performed with one spiral acquisition obtained during the hepatic arterial phase and a second acquisition during the portal venous phase

  13. Non-granulomatous prostatitis: MR appearance with an endorectal surface coil; Nichtgranulomatoese Prostatitis: Erscheinungsbild im MRT mit endorektaler Oberflaechenspule (``Endo-MRT``)

    Energy Technology Data Exchange (ETDEWEB)

    Szolar, D.H.M. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Ranner, G. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Preidler, K.W. [Magnetresonanztomographie-Zentrum, Univ. Graz (Austria); Lax, S. [Inst. fuer Pathologische Anatomie, Univ. Graz (Austria)

    1995-01-01

    Inflammatory conditions of the prostate are often idfficult to distinguish from early stages of prostate cancer with imaging techniques. The use of an endorectal surface coil in MRI of the prostate gland has been reported to provide superior resolution and better imaging of details than MRI with a body coil in the diagnosis of early prostate cancer. We report a 34-year-old patient with nonspecific non-granlomatous prostatitis in whom T{sub 2}-weighted endorectal surface coil magnetic resonance imaging (ESCMRI) showed a region of markedly decreased signal intensity in the periphery of the gland. The low signal intensity of the lesion, its sharp demarcation from the normal part of the peripheral zone of the prostate and the marked bulge of the surface contour without capsular breach of the organ were interpreted as evidence of a bioptically proven benign inflammatory condition. (orig.) [Deutsch] Die Unterscheidung entzuendlicher Prozesse von Fruehstadien maligner Neoplasien der Prostata mittels Magnetresonanztomographie bereitet immer wieder Schwierigkeiten. Die Anwendung einer Oberflaechenspule erlaubt durch hoehere Aufloesung eine exaktere Beurteilung der Prostatakapsel, was eine hoehere Treffsicherheit beim Nachweis moeglicher organueberschreitender Infiltrationen bedeutet. Wir praesentieren den Fall eines 34jaehrigen Mannes mit unspezifischer, nichtgranulomatoeser Prostatitis, bei dem das MR-Tomogramm mit endorektal plazierter Oberflaechenspule (Endo-MRT) in der Peripherzone ein Areal deutlich herabgesetzter Signalintensitaet auf T{sub 2}-gewichteten Aufnahmen zeigte. Die scharfe Begrenzung der ausgedehnten signalarmen Laesion gegenueber dem nichtbefallenen Anteil der Peripherzone beim im Endo-MRT identifizierbarer intakter Kapsel liess ein organueberschreitendes Malignom ausschliessen und bestaetigte durch histologische Aufarbeitung der Bioptate den Endo-MRT-Verdachtsbefund einer Prostatitis. (orig.)

  14. Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies

    International Nuclear Information System (INIS)

    Applegate, K.E.; Dardinger, J.T.; Herts, B.R.; Davros, W.J.; Obuchowski, N.A.; Lieber, M.L.; Maneker, A.

    2001-01-01

    Background:. Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. Objective: To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. Materials and methods: Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. Results: The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity < 35 %). The optimal technique for visualizing the LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. Conclusion: Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized. (orig.)

  15. Modern MRI of the small bowell; Moderne MRT des Duenndarms

    Energy Technology Data Exchange (ETDEWEB)

    Scharitzer, M.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2015-12-15

    variety of MR sequences has enabled not only the detection but also the characterization of pathological changes of the small intestine, which are vital for further treatment of these patients. (orig.) [German] Die radiologische Diagnostik von Erkrankungen des Duenndarms wurde in den letzten beiden Jahrzehnten einem dramatischen Wandel unterzogen. Durch rasche Fortschritte mit neuen Behandlungsmethoden und einem zunehmend therapeutischen Fokus auf transmuralen Heilungsprozessen ist eine Gesamtabklaerung des Gastrointestinaltrakts in den Mittelpunkt gerueckt. Durch die Einfuehrung der Endoskopie hat die gastrointestinale Bildgebung mit der Magen-Darm-Passage bzw. dem Enteroklysma mit einer relativ hohen Strahlenbelastung nur bedingte Einsatzmoeglichkeiten gezeigt. Die Entwicklung der Schnittbildverfahren ermoeglichte eine deutlich breitere radiologische Abklaerung abdomineller Erkrankungen. Durch schnelle Untersuchungstechniken sowie einen hohen Weichteilkontrast mit dem grossen Vorteil einer fehlenden Strahlenexposition hat die MRT des Gastrointestinaltrakts zunehmende Bedeutung gewonnen. Bei suffizienter Fuellung des Darmlumens liegt ein grosser Vorteil in der gleichzeitigen Abbildung saemtlicher Darmwandschichten, der perienteralen Strukturen sowie assoziierter abdomineller Veraenderungen. Neue MR-Sequenzen wie diffusionsgewichtete Sequenzen, dynamische Kontrastmittelsequenzen oder die MR-Fluoroskopie ermoeglichen die Detektion morphologischer Veraenderungen mit zusaetzlicher Charakterisierung dieser Darmabschnitte sowie die Beurteilung funktioneller Pathologien mit dynamischer Information ueber eine gestoerte Darmmotilitaet. Aktuelle Richtlinien europaeischer radiologischer und gastroenterologischer Organisationen haben die Bedeutung der Schnittbildverfahren und insbesondere der MRT fuer die Erstdiagnose und das Follow-up bei Patienten mit Morbus Crohn bestaetigt. Durch die Moeglichkeit der Beurteilung aller Darmwandschichten sowie dem Vorhandensein extramuraler

  16. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  17. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  18. Cerebral av angiomas: 3-dimensional demonstration by spiral CT

    International Nuclear Information System (INIS)

    Rieger, J.; Hosten, N.; Neumann, K.; Lemke, A.J.; Langer, R.; Lanksch, W.R.; Pfeifer, K.J.; Felix, R.

    1994-01-01

    In 20 patients with known or suspected supratentorial arteriovenous malformations, an attempt was made to see how far CT angiography with 3-dimensional reconstructions is able to make a diagnosis and to differentiate the various components of the angioma. Spiral CT was performed following an intravenous bolus injection of 60-80 ml of iodine containing contrast medium. In all patients the diagnosis was confirmed by intra-arterial DSA of the vertebral vessels. In 13 patients, av malformations could be diagnosed following multiplanar 3-D reconstructions which agreed with the findings on DSA. The large supplying vessels, the nidus and the large draining veins could be defined with certainty. In 6 patients follow-up examination after embolisation was performed. The results could be demonstrated in three dimensions and the success of treatment could be documented unequivocally. CT angiography with 3-D reconstruction is able to supply important information in the majority of intracranial av malformations, both during initial investigation and following treatment. (orig.) [de

  19. Radiological imaging in early diagnosis of rheumatoid arthritis. The role of ultrasound and magnetic resonance imaging; Radiologische Fruehdiagnostik der rheumatoiden Arthritis. Stellenwert von Ultraschall und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Platzgummer, H.; Schueller-Weidekamm, C. [AKH, Medizinische Universitaet Wien, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2012-02-15

    For optimal therapy management of patients with rheumatoid arthritis (RA) specific and sensitive diagnostic methods are essential for assessment of disease activity. In addition to projection radiography, imaging techniques, in particular magnetic resonance imaging (MRI) and ultrasound (US) are becoming increasingly more important for the early diagnosis of RA. The MRI and US techniques play a key role in the early imaging diagnostics of RA. Measurement of inflammation activity represents the basis of therapeutic decision-making and can be quantitatively and qualitatively determined with MRI and US. Synovitis and bone marrow edema are predictors of erosion. (orig.) [German] Fuer das optimale Therapiemanagement bei Patienten mit rheumatoider Arthritis (RA) sind spezifische und sensible diagnostische Methoden zur Beurteilung der Krankheitsaktivitaet unerlaesslich. Neben der Projektionsradiographie gewinnen die bildgebenden Methoden zur Fruehdiagnostik der RA, insbesondere die Magnetresonanztomographie (MRT) und der Ultraschall (US), zunehmend an Bedeutung. MRT und US spielen eine Schluesselrolle in der bildgebenden Fruehdiagnostik der RA. Die Messung der Entzuendungsaktivitaet stellt die Basis fuer die Therapieentscheidung dar. Sie kann mit dem US und der MRT quantitativ und semiquantitativ bestimmt werden. Synovialitis und Knochenmarkoedem sind Praediktoren fuer Erosionen. (orig.)

  20. Value of MRI in the diagnosis of stress urinary incontinence in the absence of organ descent; Beitrag der MRT in der Diagnostik der Stress-Harninkontinenz ohne begleitenden Descensus urogenitalis

    Energy Technology Data Exchange (ETDEWEB)

    Beyersdorff, D.; Taupitz, M.; Fischer, T.; Hamm, B. [Humboldt-Univ., Berlin (Germany). Inst. fuer Radiologie; Tunn, R.; Rieprich, M. [Humboldt-Univ., Berlin (Germany). Klinik fuer Gynaekologie und Geburtshilfe

    2001-07-01

    To detect pathomorphological changes of the pelvic floor, the vagina, and the urethra by MR imaging in patients with stress urinary incontinence in the absence of organ descent compared with findings in 10 healthy controls. Materials and Methods: The study included 10 healthy controls and 38 patients with stage II urinary incontinence showing no urge symptoms but a pathological stress profile on urodynamic testing. The subjects underwent MR imaging with a phased-array coil at 1.5 T in addition to urodynamic testing and gynecological examination. The following sequences were used: axial and coronal PD-weighted TSE sequences with a FOV of 20 cm and a section thickness of 4 mm; axial STIR sequence. Sagittal T{sub 2}-weighted HASTE sequences were acquired during pelvic floor contraction, relaxation, and straining maneuvers. Results: In 22/38 cases pathomorphological changes were found by MR imaging. The pathomorphological changes were classified as lateral defects (n = 14) if the musculofascial connection between the levator muscle and the lateral vaginal wall or the butterfly shape of the vagina was absent and as central (n = 16) if changes were detected in the urethral wall. Defects of the pelvic floor muscles were detected in 8 cases. No underlying changes were identified in 16/38 cases. Conclusion: In cases of female urinary incontinence, MR imaging of the pelvic floor can detect pathomorphological changes, which are difficult to identify by clinical examination. MR imaging currently does not allow the detection of morphological changes in all forms of female urinary stress incontinence. (orig.) [German] In einer prospektiven Studie sollen mittels MRT pathomorphologische Veraenderungen des Beckenbodens, der Vagina und der Urethra bei Patientinnen mit Stress-Harninkontinenz (HI) ohne begleitenden Descensus urogenitalis im Vergleich zu Patientinnen ohne HI untersucht werden. Material und Methoden: 38 Patientinnen mit Stress-HI im Stadium II wurden zusaetzlich zur

  1. TRIPLE PHASE SPIRAL C.T. IN THE EVALUATION OF HEPATIC MASSES

    Directory of Open Access Journals (Sweden)

    Prasad

    2015-10-01

    Full Text Available BACKGROUND AND OBJECTIVE : The goal of the study is to determine the value of various phases of Triple, Helical CT, Hepatic arterial Phase (HAP, Portal venous phase (PVP and Equilibrium Phase (EP, is the detection and characterization of Hepatic Lesions and to evaluate whether u nenhanced and hepatic arterial phases when used in conjunction with porto venous phase would lead to detection of greater number of lesions or better characterization of lesion. METHODOLOGY : The study population consists of 50 Patients aged between 30 Years and 80 Years were examined with multiphase (plain, hepatic arterial, portal venous and equilibrium phases. Spiral CT of liver. Patients were referred for CT scan when liver diseases were suspected clinically, if ultrasound and other previous investi gations revealed lesions which had to be further evaluated by spiral CT and to detect liver metastases in known cases of primary extra hepatic malignancy. CT TECHNIQUE: Helical scanning of liver with Toshiba astein s4, continuous spiral run and the images were reconstructed at 5mm intervals. Contrast material 100ml was injected through 18 or 20G catheter at the rate of 3ml per second using automatic medrad power injector. Non - ionic contrast [IOHEXOl – 300mg perml was used in all the patients]. After obtaine d unenhanced CT scan HAP scanning was initiated 25 seconds after initiation of contrast injection. Portal venous phase scanning was initiated 60 - 65 seconds after start of contrast injection. Equilibrium phase scanning was initiated after 180 seconds after the start of contrast injection. IMAGE EVALUATION: All the images of 4 phases were reviewed. First Step : The presence, appearance and enhancement of each Lesion were noted in all phases and lesion were described Isodense, Hypodense Hyperdense based on thei r attenuation relative to liver parenchyma during that phase of scanning. Based on enhancement pattern of the lesion during various phases they were

  2. The technique of MRT aided abdominal drainage using an open low field magnet. Feasibility and first results

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.; Schimmelpenning, H.; Weiss, H.D.

    1996-01-01

    To test the practicality of MRT-aided drainage using an open low field magnet and to report on the early clinical results. So far seven patients have been treated (four subphrenic abscesses, two psoas abscesses and one pancreatic pseudocyst). The planning of the approach and catheter insertion were carried out under MRT control (Magnetom Open, 0.2 T). Subsequent treatment was controlled by CT and fluoroscopy. Initial puncture was carried out with a non-magnetic 18 gauge Chiba needle. The drainage catheter was introduced by Seldinger's technique in six cases and with a trocar in one patient. In all seven patients drainage could be started successfully. The design of the magnet and coils permitted adequate accessibility of the patient. There were no problems in visualising the puncture needle. Controlling the position of the catheter by MRT was, however, difficult. The first two steps in abscess drainage (planning the approach and inserting the catheter) can be carried out under MRT control. For further catheter control and observing the course of the disease we presently prefer CT or fluoroscopy. (orig.) [de

  3. Mountain biking. Breezy ups and traumatic downs; Mountainbiking. Luftige Hoehen und traumatische Tiefen

    Energy Technology Data Exchange (ETDEWEB)

    Schueller, G. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria)

    2010-05-15

    For more than two decades the popularity of mountain biking as a national pastime as well as a competitive sport has been undiminished. However, its related risks are not monitored as closely as those, for example, of skiing. The injuries caused by mountain biking are specific and cannot be compared with those caused by other cycling sports. This is due not only to the characteristics of the terrain but also to the readiness to assume a higher risk compared to cycle racing. The particular value of radiology is in the acute trauma setting. Most often musculoskeletal lesions must be examined and digital radiography and MRI are the most useful techniques. Severe trauma of the cranium, face, spine, thorax and abdomen are primarily evaluated with CT, particularly in dedicated trauma centers. Therefore, radiology can play a role in the rapid diagnosis and optimal treatment of the trauma-related injuries of mountain biking. Thus, the unnecessarily high economical damage associated with mountain biking can be avoided. (orig.) [German] Mountainbiking erfreut sich seit mehr als 2 Jahrzehnten sowohl im Breiten- als auch Wettkampfsport einer ungebrochenen Popularitaet. Die assoziierten Risiken werden allerdings nicht mit derselben Aufmerksamkeit beobachtet wie etwa jene des Skisports. Die Verletzungen beim Mountainbiking sind spezifisch und nicht mit den Verletzungen vergleichbar, die bei anderen Radsportarten entstehen. Dies ist z. T. durch die Besonderheiten des Terrains und z. T. durch eine im Vergleich zum Rennradfahren hoehere Risikobereitschaft zu erklaeren. Die Radiologie hat ihren Stellenwert besonders in der Akutdiagnostik. Hier beschaeftigt sie sich v. a. mit muskuloskelettalen Verletzungen und setzt in erster Linie auf die digitale Projektionsradiographie und die MRT. Zur Evaluierung schwerer Verletzungen des Kopfs, der Wirbelsaeule, des Thorax und des Abdomens wird die CT bevorzugt, insbesondere in dezidierten Traumazentren. Damit kann die Radiologie ihren Teil

  4. Prognostic value of cardiovascular MRI in diabetics; Prognostischer Wert der kardiovaskulaeren MRT bei Diabetikern

    Energy Technology Data Exchange (ETDEWEB)

    Schlett, C.L.; Bertheau, R.C.; Kauczor, H.U.; Weckbach, S. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2015-04-01

    Risikostratifizierung von Noeten ist. Die klinische Untersuchung und die Bestimmung von Blutwerten dienen bei Diabetikern typischerweise zur Risikostratifizierung bzgl. kardio(zerebro)vaskulaerer Ereignisse in der Zukunft. Sowohl die Kardio- als auch die Ganzkoerper-MRT stellen standardisierte Verfahren in der klinischen Diagnostik dar. Deren Stellenwert bei der Vorhersage von Ereignissen mit entsprechender Risikostratifizierung bei Diabetikern gewinnt basierend auf aktuellen Studienergebnissen zunehmend an Bedeutung. Late Gadolinium Enhancement (LGE) im Kardio-MRT detektiert bei bis zu 30 % der Diabetiker stumme Myokardischaemien, die mit einer Hazard Ratio von 3-6 mit kardiovaskulaeren Ereignissen assoziiert sind. Ebenfalls zeigen linksventrikulaere Wandbewegungsstoerungen sowie eine erniedrigte Ejektionsfraktion einen prognostischen Wert. Im Ganzkoerper-MRT sind der Vessel-Score und Karotisstenosen zusaetzliche Praediktoren fuer kardio(zerebro)vaskulaere Ereignisse. Die MRT-basierte Vorhersage kardio(zerebro)vaskulaerer Ereignisse bietet einen signifikanten Mehrwert zur klassischen Risikostratifizierung bei Diabetikern. Jedoch erlaubt nur die umfassende Ganzkoerper-MRT-Untersuchung Patienten zu identifizieren, die ueber einen Zeitraum von 6 Jahren komplett frei von kardio(zerebro)vaskulaeren Ereignissen bleiben. Die Kardio-MRT, insbesondere die Erfassung von LGE, empfiehlt sich fuer die Vorhersage von Ereignissen. Die Ganzkoerper-MRT stellt einen prognostischen Mehrwert dar, deren klinische Relevanz in weiteren Studien geklaert werden muss. (orig.)

  5. Rational imaging of hepatocellular carcinoma. The challenge of multimodal diagnostic criteria; Rationale Schnittbildgebung des hepatozellulaeren Karzinoms. Die Herausforderung multimodaler Diagnosekriterien

    Energy Technology Data Exchange (ETDEWEB)

    Kircher, A.; Bongartz, G.; Merkle, E.M.; Zech, C.J. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland)

    2014-07-15

    specificity. For daily clinical routine, CT offers a fast, reliable and easy available modality with benefits for patients in reduced general state of health and restricted compliance. (orig.) [German] CT und MRT bilden den Goldstandard in der bildgebenden Diagnostik des hepatozellulaeren Karzinoms (HCC). Beide Verfahren erlauben als alleinige Untersuchung bei entsprechendem Kontrastmittelverhalten die Diagnose eines HCC. Eine radiologische Herausforderung stellen immer noch die Detektion von HCC-Laesionen < 2 cm, die Abgrenzung praemaligner und maligner Laesionen von anderen benignen Vorstufen der Hepatokarzinogenese sowie die Dignitaetseinschaetzung hypovaskulaerer Leberlaesionen in der zirrhotischen Leber dar. Beide Untersuchungsmodalitaeten erreichen inzwischen fuer Laesionen > 2 cm sehr hohe Detektionsraten zwischen 90 und 100 %. Fuer Laesionen zwischen 1 und 2 cm bestehen Vorteile der MRT mit Sensitivitaeten zwischen 80 und 90 % gegenueber 60-75 % der CT. Die MRT-Diagnostik profitiert neben den multimodalen Diagnosekriterien zusaetzlich vom Einsatz leberspezifischer Kontrastmittel, insbesondere in Kombination mit der Diffusionsbildgebung, wobei sowohl eine Erhoehung der Sensitivaet als auch der diagnostischen Genauigkeit fuer Laesionen < 2 cm nachgewiesen werden konnte. Bezueglich der Abgrenzung des HCC von anderen nodulaeren Herdlaesionen der zirrhotischen Leber hat sich gezeigt, dass die gleichzeitig vorliegende arterielle Hypervaskularisation und Hypointensitaet in der hepatobiliaeren Phase als spezifisch fuer das Vorliegen eines HCC einzustufen ist. Zudem ist ein hypointenses Signal in der hepatobiliaeren Phase mit einem hohen Vorhersagewert von bis zu 100 % fuer das Vorliegen eines High-grade-dysplastischen Knotens oder HCC assoziiert. Die MRT unter Beruecksichtigung von hepatobiliaerer und diffusionsgewichteter Bildgebung (''diffusion-weighted imaging'', DWI) stellt heutzutage die beste nichtinvasive Bilddiagnostik fuer die Detektion des HCC

  6. Cartilage tumors. Pathology and radiomorphology; Chondrogene Knochentumoren. Pathologie und Radiomorphologie

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, M. [RKK-Klinikum Freiburg, Klinik fuer Diagnostische und Interventionelle Radiologie, Kinderradiologie und Neuroradiologie SJK, Freiburg (Germany); Herget, G. [Universitaetsklinik Freiburg, Department Orthopaedie und Traumatologie, Freiburg (Germany); Kurz, P. [Universitaetsklinik Freiburg, Pathologisches Institut, Freiburg (Germany)

    2016-06-15

    Primary cartilage-forming tumors of the bone are frequent entities in the daily work of skeletal radiologists. This article describes the correlation of pathology and radiology in cartilage-forming skeletal tumors, in particular, enchondroma, osteochondroma, periosteal chondromas, chondroblastoma and various forms of chondrosarcoma. After reading, the radiologist should be able to deduce the different patterns of cartilage tumors on radiographs, CT, and MRI from the pathological aspects. Differentiation of enchondroma and chondrosarcoma is a frequent diagnostic challenge. Some imaging parameters, e. g., deep cortical scalloping (more than two thirds of the cortical thickness), cortical destruction, or a soft-tissue mass, are features of a sarcoma. Osteochondromas are bony protrusions with a continuous extension of bone marrow from the parent bone, the host cortical bone runs continuously from the osseous surface of the tumor into the shaft of the osteochondroma and the osteochondroma has a cartilage cap. Chondromyxoid fibromas are well-defined lytic and eccentric lesions of the metaphysis of the long bones, with nonspecific MRI findings. Chondroblastomas have a strong predilection for the epiphysis of long tubular bones and develop an intense perifocal bone marrow edema. Dedifferentiated chondrosarcomas are bimorphic lesions with a low-grade chondrogenic component and a high-grade noncartilaginous component. Most chondrogenic tumors have a predilection with regard to site and age at manifestation. (orig.) [German] Primaere knorpelbildende Tumoren sind haeufige Entitaeten in der taeglichen Arbeit des Radiologen. Der Beitrag beschreibt die Korrelation von Pathologie und Radiologie knorpelbildender Skeletttumoren, insbesondere von Enchondrom, Osteochondrom, periostalem Chondrom, Chondroblastom, und verschiedenen Varianten des Chondrosarkoms. Nach Lesen des Beitrags kann der Radiologe die verschiedenen typischen Muster knorpelbildender Tumoren im Roentgenbild

  7. Spiral CT arthrography of the knee: technique and value in the assessment of internal derangement of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Vande B.C.; Lecouvet, F.E.; Maldague, B.; Malghem, J. [Department of Radiology, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium); Poilvache, P. [Department of Orthopedic Surgery, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2002-07-01

    Computed tomography imaging has achieved excellent multiplanar capability and submillimeter spatial resolution due to the development of the spiral acquisition mode and multidetector row technology. Multidetector spiral CT arthrography (CTA) yields valuable information for the assessment of internal derangement of the joints. This article focuses on the value of spiral CTA of the knee in the assessment of the meniscus, anterior cruciate ligament, and hyaline cartilage lesions. Advantages and disadvantages of spiral CTA with respect to MR imaging are presented. (orig.)

  8. Inflammatory lesions of the spinal cord and the nerve roots in magnetic resonance imaging; Entzuendliche Erkrankungen des Rueckenmarks und der Nervenwurzeln in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Sartoretti-Schefer, S. [Inst. fuer Neuroradiologie, Universitaetsspital Zuerich (Switzerland); Wichmann, W. [Inst. fuer Neuroradiologie, Universitaetsspital Zuerich (Switzerland); Valavanis, A. [Inst. fuer Neuroradiologie, Universitaetsspital Zuerich (Switzerland)

    1996-11-01

    und immunkompetenten Patienten eingeteilt, was teilweise Rueckschluesse auf die zugrundeliegende Aetiologie erlaubt. Der immunsupprimierte Patient leidet vor allem an viralen (Herpes simplex, Herpes zoster, Zytomegalie, HIV-Virus) sowie an bakteriellen (Tuberkulose, selten Syphilis), aber nur selten an parasitaeren Infektionen. Der immunkompetente Patient erkrankt vor allem an bakteriellen Infektionen (Borreliose) sowie an immunologisch bedingten entzuendlichen Erkrankungen (Sarkoidose) und an demyelinisierenden Laesionen. Haeufig ist auch die idiopathische Myelitis. Virale Infektionen sind selten. Die MRT-Morphologie der entzuendlichen Laesionen wird durch sekundaere ischaemische und demyelinisierende Veraenderungen kompliziert, wodurch die Differentialdiagnose sehr erschwert sein kann, da das gesamte Spektrum von demyelinisierenden bzw. ischaemischen und entzuendlichen Erkrankungen miteinbezogen werden muss. Zudem koennen auch tumoroese Prozesse eine Myelitis bzw. Radikulitis nachahmen. (orig.)

  9. Spiral hydro-CT of the pancreas in the thin-slice method

    International Nuclear Information System (INIS)

    Richter, G.M.; Simon, C.; Hoffmann, V.; DeBernardinis, M.; Seelos, R.; Senninger, N.; Kauffmann, G.W.

    1996-01-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [de

  10. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  11. Pancreatitis. An update; Pankreatitis. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Schreyer, A.G. [Universitaetsklinikum Regensburg, Institut fuer Roentgendiagnostik, Regensburg (Germany); Grenacher, L. [Diagnostik Muenchen, MVZ Radiologie, Muenchen (Germany); Juchems, M. [Klinikum Konstanz, Diagnostische und Interventionelle Radiologie, Konstanz (Germany)

    2016-04-15

    Acute and chronic pancreatitis are becoming increasingly more severe diseases in the western world with far-reaching consequences for the individual patient as well as the socioeconomic situation. This article gives an overview of the contribution of radiological imaging to the diagnostics and therapy of both forms of the disease. Acute pancreatitis can be subdivided into severe (20 %) and mild manifestations. The diagnostics should be performed with computed tomography (CT) or magnetic resonance imaging (MRI) for assessing necrosis or potential infections only in severe forms of pancreatitis. In chronic pancreatitis transabdominal ultrasound should initially be adequate for assessment of the pancreas. For the differential diagnosis between pancreatic carcinoma and chronic pancreatitis, MRI with magnetic resonance cholangiopancreatography (MRCP) followed by an endoscopic ultrasound-guided fine needle aspiration is the method of choice. For the primary diagnosis for acute and chronic pancreatitis ultrasound examination is the modality of first choice followed by radiological CT and MRI with MRCP examinations. (orig.) [German] Akute und chronische Pankreatitis sind in der westlichen Welt zunehmende schwere Krankheitsbilder mit tiefgreifenden Konsequenzen fuer den einzelnen Patienten sowie soziooekonomisch. Der Beitrag radiologischer Bildgebung zur Diagnostik und Therapie beider Erkrankungsformen soll im vorliegenden Uebersichtsbeitrag diskutiert werden. Die akute Pankreatitis kann in eine schwere (20 %) und milde Verlaufsform unterteilt werden. Lediglich bei den schweren Formen sollte eine CT- oder MRT-Diagnostik bzgl. der Beurteilung von Nekrosen und moeglichen Infektionen erfolgen. Bei der chronischen Pankreatitis genuegt zunaechst eine Beurteilung des Pankreas durch transabdominellen Ultraschall. Hier sind die MRT mit der Magnetresonanzcholangiopankreatikographie (MRCP) sowie die endosonographisch gesteuerte Feinnadelpunktion die Methode, um

  12. Fetal magnetic resonance imaging: methods and techniques; Fetale Magnetresonanztomographie: Methoden und Technik

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.C. [Zentrum fuer Anatomie und Zellbiologie, Medizinische Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie; Stuhr, F.; Lindner, C.; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    Since the introduction of fetal magnetic resonance imaging (MRI) into prenatal diagnostics, advances in coil technology and development of ultrafast sequences have further enhanced this technique. At present numerous sequences are available to visualize the whole fetus with high resolution and image quality, even in late stages of pregnancy. Taking into consideration the special circumstances of examination and adjusting sequence parameters to gestational age, fetal anatomy can be accurately depicted. The variety of sequences also allows further characterization of fetal tissues and pathologies. Fetal MRI not only supplies additional information to routine ultrasound studies, but also reveals fetal morphology and pathology in a way hitherto not possible. (orig.) [German] Seit Einfuehrung der fetalen Magnetresonanztomographie (MRT) in die praenatale Diagnostik wurde das Verfahren durch neue Spulentechniken und die Entwicklung ultraschneller Sequenzen kontinuierlich weiter entwickelt. Gegenwaertig steht eine Vielzahl von Sequenzen zur Verfuegung, die es erlauben, mit hoher Bildqualitaet und raeumlicher Aufloesung selbst in fortgeschrittenen Schwangerschaftsstadien den gesamten Feten darzustellen. Unter Beruecksichtigung der speziellen Untersuchungsbedingungen und des Schwangerschaftsalters kann so die fetale Anatomie genau abgebildet werden. Die Vielfalt an Sequenzen und deren gezielter Einsatz ermoeglichen es weiter, fetale Gewebe und Pathologien naeher zu charakterisierten. Auf diese Weise liefert die fetale MRT nicht nur Zusatzinformationen zur Routineultraschalluntersuchung, sie gibt auch Aufschluss ueber bestimmte fetale Morphologien und Pathologien, die bisher nicht darstellbar waren. (orig.)

  13. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  14. Deformation and fracture properties of metals with non-metallic inclusions; Verformung und Bruch von Metallen mit nichtmetallischen Einschluessen

    Energy Technology Data Exchange (ETDEWEB)

    Schmauder, S.; Soppa, E. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1998-12-31

    Microstructural effects due to formation of non-uniform lines of non-metallic inclusions in the matrix are examined with respect to their macro-, meso-, and micromechanical effects in the alloy Al(6061) reinforced by SiC inclusions. A comparative analysis of results obtained with various microstructures reveals essential differences in the formation of shear bands, stress peaks, and strain concentrations in the material structure. The maxima and the distribution of those field variables are determined not only by the arrangement of inclusions clusters in the stringers but also depend on the presence and number of single-particle inclusions in pure matrix material. The banding of the microstructure causes a strongly anisotropic behaviour in terms of stress and strain distributions. (orig./CB) [Deutsch] In diesem Beitrag werden Gefuegeeinfluesse aufgrund unterschiedlich starker zeiliger Anordnungen der Teilchen in der Matrix im Hinblick auf ihre makro-, meso- und mikromechanischen Auswirkungen am Beispiel einer SiC-teilchenverstaerkten Aluminiumlegierung Al(6061) untersucht. Ein Vergleich der Ergebnisse verschiedener Gefuege zeigt wesentliche Unterschiede hinsichtlich der Ausbildung von Scherbaendern, Spannungsspitzen und von Dehnungskonzentrationen im Werkstoffgefuege. Die Maxima und die Verteilung dieser Feldgroessen sind nicht nur abhaengig davon, wie die Teilchen in den Zeilen angeordnet sind, sondern auch davon, ob einzelne Teilchen in reinen Matrixbereichen vorhanden sind. Die Zeiligkeit des Gefueges fuehrt zu einem stark anisotropen Verhalten hinsichtlich Spannungs- und Dehnungsverteilungen. (orig.)

  15. MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis

    International Nuclear Information System (INIS)

    Berg, B.C. vande; Lecouvet, F.E.; Maldague, B.; Malghem, J.

    2004-01-01

    The aim of this study was to determine signal intensity patterns of cartilage defects at MR imaging. The MR imaging (3-mm-thick fat-suppressed intermediate-weighted fast spin-echo images) was obtained in 31 knees (21 male and 10 female patients; mean age 45.5 years) blindly selected from a series of 252 consecutive knees investigated by dual-detector spiral CT arthrography. Two radiologists determined in consensus the MR signal intensity of the cartilage areas where cartilage defects had been demonstrated on the corresponding reformatted CT arthrographic images. There were 83 cartilage defects at spiral CT arthrography. In 52 (63%) lesion areas, the MR signal intensity was higher than that of adjacent normal cartilage with signal intensity equivalent to (n=31) or lower than (n=21) that of articular fluid. The MR signal intensity was equivalent to that of adjacent normal cartilage in 17 (20%) lesion areas and lower than that of adjacent cartilage in 8 (10%) lesion areas. In 6 (7%) lesion areas, mixed low and high signal intensity was observed. The MR signal intensity of cartilage defects demonstrated on spiral CT arthrographic images varies from low to high on fat-suppressed intermediate-weighted fast spin-echo MR images obtained with our equipment and MR parameters. (orig.)

  16. MRI of the hyaline knee joint cartilage. Animal experimental and clinical studies; MRT des hyalinen Kniegelenkknorpels. Tierexperimentelle und klinische Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Adam, G. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Prescher, A. [Technische Hochschule Aachen (Germany). Inst. fuer Anatomie; Nolte-Ernsting, C. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Buehne, M. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Scherer, K. [Technische Hochschule Aachen (Germany). Inst. fuer Versuchstierkunde; Kuepper, W. [Technische Hochschule Aachen (Germany). Inst. fuer Versuchstierkunde; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1994-02-01

    The value of MR imaging for the detection of hyaline cartilage lesions using 2-D spin-echo and 3-D gradient-echo imaging was evaluated in an animal experiment in 10 dogs and in a clinical study in 30 patients. MR imaging findings were compared with histopathological and arthroscopy findings, respectively. Using MRI neither grade I nor grade II hyaline cartilage lesions were detectable. In the animal experiments 77% of grade III lesions and all the grade IV lesions were seen. However, in the clinical study only about the half of grade III and IV lesions were detected. 3-D gradient-echo MR imaging was superior to 2-D spin-echo imaging (p<0.001), while 3-D FLASH and 3-D FISP did not differ significantly in the detection rate (p<0.34). 3-D gradient-echo MR imaging seems to be the best method for the delineation of high grade cartilage lesions. However, early stages of cartilage degeneration are invisible even with this imaging modality. (orig.) [Deutsch] Die Wertigkeit der MRT in der Erfassung von Knorpellaesionen mit 2-D-Spin-Echo- und 3-D-Grafienten-Echo-Sequenzen wurde in einer tierexperimentellen Untersuchung an 10 Hunden sowie in einer klinischen Studie an 30 Patienten ueberprueft. Die kernspintomographischen Ergebnisse wurden mit dem pathologisch-anatomischen Befund bzw. der Arthroskopie verglichen. MR-tomographisch konnten weder Grad-I- noch Grad-II-Knorpellaesionen erfasst werden. Die Erkennbarkeitsrate der Grad-III- und -IV-Laesionen lag fuer die tierexperimentellen Untersuchungen bei 77 bzw. 100%, waehrend klinisch nur etwa 50% dieser Veraenderungen erkannt werden konnten. Dabei waren die 3-D-Gradienten-Echo-Sequenzen den 2-D-Spin-Echo-Sequenzen signifikant ueberlegen (p<0,001), waehrend sich die 3-D-Gradienten-Echo-Sequenzen FISP und FLASH nicht voneinander unterschieden (p<0,34). Derzeit muessen die 3-D-Gradienten-Echo-Sequenzen als die beste Methode zur Erfassung hoehergradiger Knorpellaesionen angesehen werden. Fruehe Stadien der Knorpelschaedigung sind

  17. Diagnostic imaging in polytrauma: comparison of radiation exposure from whole-body MSCT and conventional radiography with organ-specific CT; Radiologische Bildgebung beim Polytrauma: Dosisvergleich von Ganzkoerper-MSCT und konventionellem Roentgen mit organspezifischer CT

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Lorenzen, M.; Weber, C.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nagel, H.D. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2004-07-01

    Purpose: To compare the radiation dose of whole-body multislice CT (MSCT) and conventional radiography with organ-specific CT in polytrauma. Materials and Methods: The whole-body MSCT encompassing brain, neck and midface, chest, abdomen and pelvis was performed on a Somatom Volume Zoom (Siemens). Conventional radiography consisted of chest and cervical, thoracic and lumbar spine in two views as well as pelvis. Polymat, Siemens. Three combinations of organ specific CT were chosen: CT examination of (1) head and cervical spine, (2) head, cervical spine and chest, (3) head, cervical spine and abdomen. The effective doses of whole-body MSCT and conventional radiography with organ-specific CT were calculated. Results: Effective doses were 20 mSv for whole-body MSCT, 2 mSv for conventional x-ray, and 5 mSv for combination (1), 8 mSv for combination (2) and (3) 16 mSv for combination (3) of the organ-specific CT. The ratio of radiation dose between whole-body MSCT and radiography was 10: 1. This ratio was reduced to 3: 1, 2: 1 and 1: 1 when a combination of radiography and CT was performed. Conclusions: Whole-body MSCT in polytrauma compared to conventional radiography with organ-specific CT induces a threefold increased dose in unfavorable situations and no increased dose in favorable situations. Nevertheless, routine use of whole-body MSCT should be critically evaluated and should be adapted to the clinical benefit. (orig.) [German] Ziel: Dosisvergleich von Ganzkoerper-MSCT und konventioneller Basisdiagnostik mit organspezifischen Ct-Untersuchungen beim Polytrauma. Material und Methoden: Die Ganzkoerper-MSCT-Untersuchung von Schaedel, Mittelgesicht, HWS sowie Thorax, Abdomen und Becken erfolgte an einem Somatom-Volume-Zoom (Siemens). Die konventionelle Bildgebung, bestehend aus Thorax, Becken, HWS, BWS und LWs, wurde an einem Siemens-Polymat durchgefuehrt. Fuer die organspezifischen CT-Untersuchungen wurden 3 Kombinationen ausgewaehlt: (1) CCT + HWS, (2) CCT + HWS

  18. Diffusion formation and psychiatric diseases; Diffusionsbildung und psychiatrische Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Kulikovski, J. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2015-09-15

    The basic principle behind diffusion is Brownian motion. The diffusion parameters obtained in a clinical association provide information on the spatial distribution of water molecule mobility and, therefore, evidence of the morphological integrity of the white and grey matters of the brain. In recent years functional magnetic resonance imaging (fMRI) could contribute to obtaining a detailed understanding of the cortical and subcortical cerebral networks. Diffusion tensor imaging (DTI) investigations can demonstrate the extent of anisotropy and the fiber pathways in so-called parametric images. For example, in Alzheimer's disease DTI reveals a reduced structural connectivity between the posterior cingulum and the hippocampus. This article shows examples of the application of diffusion-weighted imaging (DWI) in psychiatric disorders. (orig.) [German] Die Grundlagen der Diffusion bildet die brownsche Molekularbewegung. Die im klinischen Zusammenhang gewonnenen Diffusionsparameter geben Auskunft ueber die raeumliche Verteilung der Wassermolekuelmobilitaet und damit Hinweise auf die morphologische Integritaet der weissen und grauen Hirnsubstanz. Die funktionelle MRT (fMRT) konnte in den letzten Jahren dazu beitragen, ein detailliertes Verstaendnis der kortikalen und subkortikalen zerebralen Netzwerke zu erlangen. Diffusion-tensor-imaging(DTI)-Untersuchungen koennen in sogenannten Parameterbildern das Ausmass der Anisotropie und den Faserverlauf darstellen. So zeigte z. B. die DTI bei der Alzheimer-Demenz eine verminderte strukturelle Konnektivitaet zwischen dem posterioren Zingulum und dem Hippokampus. Dieser Beitrag zeigt Beispiele der Anwendung der Diffusionsbildgebung (''diffusion-weighted imaging'', DWI) bei psychiatrischen Erkrankungen. (orig.)

  19. Noninvasive diagnosis of suspected severe pulmonary embolism. Trans-esophageal echocardiography vs spiral CT

    International Nuclear Information System (INIS)

    Pruszczyk, P.; Torbicki, A.; Pacho, R.

    1998-01-01

    Patients with pulmonary embolism (PE) and echocardiographic signs of right ventricular over-lead have worse prognosis and may be require aggressive therapy. Unequivocal confirmation of PE is required before thrombolysis or embolectomy. This study compares the value of trans-esophageal echocardiography (TEE) and spiral CT (sCT) in direct visualization of pulmonary artery thrombo-emboli in patients with suspected PE and echocardiographic signs of right ventricular over-lead. Because of high prevalence of bilateral central pulmonary thrombo-emboli in patients with hemo-dynamically significant PE, both sCT and TEE allow its definitive confirmation in most cases. Thrombi reported by sCT distally to lobar arteries should be interpreted with caution. (author)

  20. Cerebrospinal fluid leakage. Indications, technique and results of treatment with a blood patch; Liquorverlustsyndrom. Indikation, Technik und Ergebnisse der Behandlung mit ''blood patch''

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk, A. [Krankenhaus Nordwest, Abteilung Neuroradiologie, Frankfurt am Main (Germany)

    2015-06-15

    of several months, even though patients are already free of symptoms. In total, blood patch therapy is a safe and technically relative simple method with a high success rate. Therefore, it represents the therapy of choice in patients with spontaneous cerebrospinal fluid leakage as well as in cases of post-lumbar puncture syndrome refractory to conservative therapy. (orig.) [German] In den meisten Faellen ist ein Liquorverlustsyndrom iatrogen durch Lumbalpunktionen, Periduralanaesthesien oder operative Eingriffe an der Wirbelsaeule bedingt. Durch verbesserte diagnostische Moeglichkeiten werden jedoch auch spontane Liquorverlustsyndrome mit zunehmender Haeufigkeit diagnostiziert, deren Ursache oft nicht eindeutig zu klaeren ist. Zur radiologischen Diagnosesicherung und zur Lokalisierung des Liquorlecks stehen mit der Postmyelo-CT, der {sup 111}Indium-Radioisotopenzisternographie und der (Myelo-)MRT mehrere Verfahren mit unterschiedlichen Sensitivitaeten zur Verfuegung. Nach unserer eigenen Erfahrung ist eine primaer nativdiagnostische MRT mit fettsaturierten T2-Sequenzen in vielen Faellen bereits diagnostisch ausreichend, um das Liquorleck und seine Lokalisation zu sichern. In den uebrigen Faellen ist die Durchfuehrung einer ergaenzenden Postmyelo-CT oder alternativ einer Myelo-MRT empfehlenswert. Bei manchen Patienten mit spontanem Liquorverlustsyndrom finden sich dabei mehrere Liquorlecks auf unterschiedlichen Hoehen. Leitsymptom ist in den meisten Faellen ein lageabhaengiger orthostatischer Kopfschmerz. Waehrend das postpunktionelle Syndrom unter Bettruhe und medikamentoeser Therapie oft selbstlimitierend ist, bedarf es beim spontanen Liquorverlustsyndrom meist einer Blood-patch-Therapie. Der lumbale ''blood patch'' kann in der Regel problemlos unter Durchleuchtungskontrolle erfolgen. Bei einem ''blood patch'' an der HWS oder BWS wird aus Sicherheitsgruenden eine CT-gesteuerte Durchfuehrung empfohlen, um eine streng epidurale

  1. Preoperative assessment of gastric artery in patients with gastric cancer by CT angiography on 64-slice spiral CT

    International Nuclear Information System (INIS)

    Tang Lei; Zhang Xiaopeng; Sun Yingshi; Cao Kun; Qi Liping; Cui Yong; Wang Ning

    2010-01-01

    Objective: To evaluate the efficacy of different three-dimensional CTA methods on 64-slice sprial CT in the preoperative assessment of gastric arteries and their variations. Methods: Sixty-six consecutive patients with gastric cancer who underwent 64-slice spiral CT examinations preoperatively were retrospectively studied. To get the STS-MIP images, the thickness of slab was adjusted according to the inner diameter of targeted blood vessels and their cross-layer distribution. After four weeks, the AVVR images of all cases was got by the auto-vessel technique. The demonstration rates and origins of the direct and indirect feeding arteries were analyzed on AVVR and STS-MIP. McNemar tests were used to compare the detection rates of gastric feeding arteries by STS-MIP and AVVR. The relationship between CT value and display rate of vessels was analyzed using independent-samples t test. The variations of blood vessels were analyzed. Results: The display rate of indirect feeding arteries were all 100% (66/66) by STS-MIP and AVVR. The display rates of left gastric artery (LGA) and right gastroepiploic artery (RGEA) were 98.5% (65/66), 100.0% (66/66) and 97.0% (64/66), 100.0% (66/66) by STS-MIP and AVVR respectively. The display rates of right artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (PGA) by AVVR were lower than those of STS-MIP with statistical significances [RGA: 68.2% (45/66) vs. 98.5% (65/66), P<0.01; LGEA: 53.0% (35/66) vs. 97.0% (64/66), P<0.01; SGA: 7.6%(5/66) vs. 59.1% (39/66), P<0.01; PGA: 18.2% (12/66) vs. 63.6% (42/66), P<0.01]. The demonstration rates of LGEA, RGEA and SGA increased accompanied with the increasing of CT value in celiac axis (LGEA: 35 cases displayed with mean CT value of (272 ± 44) HU, 31 cases did not display with mean CT value of (229 ± 42) HU, t=4.043, P<0.01; RGEA: 64 cases

  2. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W.; Kuwert, T. [Nuklearmedizinische Klinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Beckmann, M.W. [Frauenklinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Forst, R. [Lehrstuhl fuer Orthopaedie mit Orthopaedischer Chirurgie, Friedrich-Alexander Univ. Erlangen/Nuernberg (Germany); Bautz, W. [Radiologisches Inst., Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany)

    2005-07-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  3. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    International Nuclear Information System (INIS)

    Roemer, W.; Kuwert, T.; Beckmann, M.W.; Forst, R.; Bautz, W.

    2005-01-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  4. Comparison of radiation dose and image quality of Siremobil-IsoC{sup 3D} with a 16-slice spiral CT for diagnosis and intervention in the human pelvic bone; Vergleich von Strahlenexposition und Bildqualitaet eines Siremobil-IsoC{sup 3D} mit einem 16-Zeilen-Spiral-CT bei Diagnostik und Intervention am humanen Becken

    Energy Technology Data Exchange (ETDEWEB)

    Wieners, G.; Pech, M.; Beck, A.; Wust, P.; Felix, R.; Schroeder, R.J. [Klinik fuer Strahlenheilkunde, Charite, Univ. Berlin (Germany); Koenig, B.; Erdmenger, U.; Stoeckle, U. [Klinik fuer Unfallchirurgie, Charite, Univ. Berlin (Germany)

    2005-02-01

    Purpose: to compare the image quality of 16-slice computed tomography with the image quality of Siremobil-IsoC{sup 3D} of the pelvic region and to measure simultaneously the radiation dose before and after implantation of a sacroiliac screw (SI-screw) Materials and methods: the pelvic region of 8 human cadavers was examined in the Siremobil-IsoC{sup 3D} at five different levels. We used a standard protocol for the 16-slice CT of the complete pelvic region before and after insertion of a pelvic screw, followed by stepwise reduction of the tube current to find the tube current that equalizes the image quality of both modalities. We controlled the image quality by judging important structures such as neuroforamen, nerves, sacroiliacal joint space, intervertebral space, osteophytes, iliopsoas muscle, acetabular surface, fovea centralis, hip joint and os pubis. The image quality was judged by three radiologists and three trauma surgeons using a ranking from 1 to 5. The dose was measured with an endorectally placed NOMEX Dosimeter, to obtain the gonadal dose. Results: the medium score for all viewers of the Siremobil-IsoC{sup 3D} examinations was between 3 and 4.3. The medium score for all CT-examinations with a tube current of 250 mA was between 1.3 and 2.2. The reduction of tube current down to 80 mA hardly influenced the marks for the analyzed structures. Under 80 mA, bony structures, even after implantation of a SI-screw, were still marked as good, but soft tissue differentiation was getting worse. For the examination of the pelvis, the average dose-length product for the IsoC{sup 3D} was 41.2 mGy x cm. The medium dose-length product for CT was 389 mGy x cm for 250 mA, 125 mGy x cm for 80 mA and 82 mGy x cm for 60 mA. (orig.)

  5. Mediastinal fibrosis with pulmonary artery obstruction; diagnosis and investigation with helical CT imaging including 3-dimensional reconstructions; Pulomonalarterienstenose bei aggresiver Mediastinalfibrose; Diagnostik und 3D-Darstellung mittels helikaler CT-Untersuchung

    Energy Technology Data Exchange (ETDEWEB)

    Kolbe, M. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland); Helwig, A. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland); Habicht, J.M. [Klinik fuer Herz-Torax-Chirurgie, Universitaetskliniken Basel (Switzerland); Steinbruch, W. [Inst. fuer Diagnostische Radiologie, Kantonsspital Basel (Switzerland)

    1997-07-01

    An aggressive mediastinal fibrosis was found in a 42-year-old female, suffering from dysphagia, stabbing pain in the chest, and an unclear weight loss. In this case, the rare combination of esophageal involvement, bronchial narrowing, and pulmonary artery obstruction could easily be demonstrated with a barium study and a helical CT examination including three-dimensional reconstructions. (orig.) [Deutsch] Wir stellen den Fall einer 42jaehrigen Patientin vor, welche zur Abklaerung einer zunehmenden Dysphagie, stechender Thoraxschmerzen und eines Gewichtsverlustes hospitalisiert wurde. Mittels klinischer und radiologischer Abklaerung konnte eine aggressive Mediastinalfibrose diagnostiziert werden. Die seltene Kombination einer Oesophaguseinengung mit Pulmonalarterienstenosen sowie einer Bronchuskompression konnte nichtinvasiv mittels Oesophagogramm und helikaler CT-Untersuchung zuverlaessig und schnell dargestellt werden. (orig.)

  6. Diagnostics for diseases of the gallbladder and biliary tract from the viewpoint of the internist and surgeon. Demands made on radiological diagnostics; Diagnostik von Erkrankungen der Gallenblase und - Wege aus Sicht des Internisten und Chirurgen. Anforderungen an die radiologische Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Reimann, F.M. [Krankenhaus Salem, Heidelberg (Germany); Friess, H. [Krankenhaus Salem, Heidelberg (Germany); Universitaetsklinikum Heidelberg (Germany). Abteilung fuer Allgemein-, Viszeral- und Unfallchirurgie

    2005-11-01

    Jaundice and colic pain of the right upper quadrant are the main symptoms of biliary diseases. Gallstone-related diseases often lead to hospital admission. The evaluation of a patient with biliary symptoms requires a combination of history taking, physical examination, laboratory analysis, and imaging modalities. A high-quality magnetic resonance imaging (MRI) or computed tomography (CT) scan is usually sufficient to evaluate a patient with painless jaundice. Ultrasonography is helpful as an initial screening test to guide the diagnostic work-up. Invasive methods (e.g., ERCP) are mainly used for palliation of patients with incurable disease. (orig.) [German] Erkrankungen der Gallenwege manifestieren sich mit den beiden Kardinalsymptomen Ikterus und kolikartigen rechtsseitigen Oberbauchschmerzen. Die durch Gallensteine verursachten Beschwerden und Erkrankungen zaehlen zu den haeufigsten gastroenterologischen Krankheitsbildern, die eine Klinikaufnahme erfordern. Die Abklaerung eines Patienten mit biliaeren Symptomen erfolgt durch eine Kombination von Anamnese, Medikamentenanamnese, koerperlicher Untersuchung, Laboranalysen und bildgebenden Verfahren. Bei Patienten mit malignen Tumoren im Bereich der ableitenden Gallenwege reichen in vielen Faellen Computertomographie (CT) oder Magnetresonanztomographie (MRT) zur Abklaerung des schmerzlosen Ikterus aus, um Therapieentscheidungen fuer den Patienten zu faellen. Der Ultraschall ist fuer die Planung der weiteren Diagnostik oft entscheidend. Der Stellenwert invasiver Methoden, wie z. B. der endoskopischen retrograden Cholangio-Pankreatikographie (ERCP), liegt vornehmlich in der Intervention, insbesondere zur Palliation bei Patienten, deren Erkrankung nicht mehr heilbar ist. (orig.)

  7. Advanced MRI techniques of the fetal brain; Zukunftsweisende MRT-Techniken des fetalen Gehirns

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, V.; Dittrich, E.; Berger-Kulemann, V.; Kasprian, G.; Kollndorfer, K.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2013-02-15

    Evaluation of the normal and pathological fetal brain. Magnetic resonance imaging (MRI). Advanced MRI of the fetal brain. Diffusion tensor imaging (DTI) is used in clinical practice, all other methods are used at a research level. Serving as standard methods in the future. Combined structural and functional data for all gestational ages will allow more specific insight into the developmental processes of the fetal brain. This gain of information will help provide a common understanding of complex spatial and temporal procedures of early morphological features and their impact on cognitive and sensory abilities. (orig.) [German] Evaluierung des gesunden bzw. pathologischen fetalen Gehirns. Die Magnetresonanztomographie. Zukunftsweisende Techniken in der MRT-Bildgebung des fetalen Gehirns. Die Diffusionstensorbildgebung (DTI) befindet sich bereits in der klinischen Anwendung, alle anderen Methoden sind bisher noch als experimentell zu werten. Auf dem Weg zur Etablierung als Standardverfahren. Eine kombinierte Verarbeitung funktioneller und struktureller Daten, modelliert fuer jede Schwangerschaftswoche, wird es zukuenftig ermoeglichen, anhand dieser fusionierten Informationen einen praezisen Einblick in den Entwicklungsprozess des Gehirns zu erlangen. Diese Erkenntnisse und Ergebnisse werden entscheidend zur Klaerung des zeitlichen Verlaufs und des komplexen Aufbaus frueher morphologischer Auffaelligkeiten beitragen sowie deren Einfluss auf kognitive und sensorische Faehigkeiten aufzeigen. (orig.)

  8. Utility of coronal oblique slices in cervical spine MRI. Improved detection of the neuroforamina; Nutzen der halbkoronaren Schichtung im MRT der Halswirbelsaeule. Verbesserte Erkennbarkeit von Neuroforamina

    Energy Technology Data Exchange (ETDEWEB)

    Freund, W.; Hoepner, G. [Universitaetskliniken Ulm, Klinik fuer Diagnostische und Interventionelle Radiologie, Ulm (Germany); Klessinger, S. [Nova Clinic Biberach, Neurochirurgie, Biberach (Germany); Universitaetskliniken Ulm, Neurochirurgie, Ulm (Germany); Mueller, M. [Universitaetskliniken Ulm, Klinik fuer Diagnostische und Interventionelle Radiologie, Ulm (Germany); Universitaetskliniken Aachen, Diagnostische und Interventionelle Neuroradiologie, Aachen (Germany); Halatsch, M.E. [Universitaetskliniken Ulm, Neurochirurgie, Ulm (Germany); Weber, F. [Bundeswehrkrankenhaus Ulm, Neurologie, Ulm (Germany); Schmitz, B. [Universitaetskliniken Ulm, Neuroradiologie, Ulm (Germany)

    2015-11-15

    Angulated projections are standard in conventional radiography of the cervical spine, but rarely used in magnetic resonance imaging (MRI). As neuroforaminal pathology plays an important role in the etiology of radicular syndromes and may influence an operative approach, the utility of coronal oblique slices in MRI is explored. In a retrospective setting, 25 consecutive patients with neurologically diagnosed cervical monoradiculopathy were identified. T2-weighted sagittal, coronal oblique, and transversal slice orientations were anonymized. Two radiologists and two neurosurgeons independently assessed the cases. Criteria were site, cause, and grading of the neuroforaminal stenosis and the level of confidence on a 100-point visual analog scale (VAS). We computed interrater agreement, sensitivity, and t tests. Using only one slice orientation, the sensitivity in detecting the relevant neuroforamen was 0.40 for transversal, 0.68 for sagittal, and 0.64 for coronal oblique scans. A combination of the different angulations increased sensitivity and in 4 cases only the coronal oblique scans proved diagnostic. The readers felt significantly more confident in attributing the cause of the pathology on coronal oblique planes (a mean of 72 VAS points, p = 0.0003 vs 58 (sagittal) vs 64 (transversal)). Interrater agreement was significantly better for experienced (kappa 0. 48) than for inexperienced readers (0.32, p = 0.02). Adding coronal oblique planes in cervical spine MRI increases sensitivity and confidence in attributing the cause of neuroforaminal pathology. They are regarded as useful by all the readers. (orig.) [German] Im Gegensatz zur Magnetresonanztomographie (MRT) sind in der konventionellen Roentgendiagnostik der Halswirbelsaeule (HWS) Schraegaufnahmen Standard. Da neuroforaminale Pathologien wichtige Ursachen von radikulaeren Syndromen sind und die Operationstechnik moeglicherweise beeinflussen, wird der Nutzen halbkoronarer Schichten in der MRT untersucht. In

  9. MRI in dementia-type diseases; MRT bei demenziellen Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Bodea, S.V.; Muehl-Benninghaus, R. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg (Germany)

    2015-05-01

    Dementia-inducing conditions represent a leading cause of disability and are a major health concern in industrialized countries. The burden these conditions put on society is certain to rise in the context of an ever-increasing elderly population. As these conditions feature an insidious onset and overlapping clinical features, imaging is a powerful tool in refining the diagnosis and assessing the progression of dementing conditions. The radiologist needs to be aware of and be able to detect underlying pathologies which could be reversible. Furthermore, imaging is important not only in excluding other pathologies but also in improving diagnostic accuracy. This article presents the typical clinical presentations as well as magnetic resonance imaging (MRI) features of the degenerative and the non-degenerative causes of dementia. The focus is on the core knowledge for MRI diagnostics in dementing conditions and a brief presentation of the latest MRI techniques which may become a part of standard imaging protocols in the future. (orig.) [German] Demenzielle Erkrankungen gehoeren in den Industrielaendern zu den haeufigsten Ursachen fuer Beeintraechtigungen im Alltag. Durch eine stetig alternde Population nimmt auch die Belastung fuer die Gesellschaft immer weiter zu. Bei haeufig schleichendem Symptombeginn sowie sich ueberlappender Klinik mit anderen Krankeitsbildern kann die Bildgebung ein gutes Werkzeug zur Praezisierung der Diagnose und Beurteilung eines Progresses sein. Der Radiologe sollte andere und reversible Pathologien erkennen und von demenztypischen Veraenderungen abgrenzen koennen. Dieser Artikel beschreibt typische klinische Symptome und auch bildmorphologische Veraenderungen verschiedener Demenzformen, die durch neurodegenerative und nichtdegenerative Ursachen bedingt sein koennen. Ausserdem werden aktuellste MRT-Techniken vorgestellt. Diese koennten kuenftig im Standartprotokoll zur Bildgebung bei der Abklaerung demenzieller Syndrome verankert sein. (orig.)

  10. Das Volkslied in Deutschland, Frankreich, Belgien und Holland. Untersuchungen über die Auffassung des Begriffes; Über die traditionellen Zeilen, die Zahlen-, Blumen- und Farbensymbolik

    NARCIS (Netherlands)

    Brouwer, Cornelis

    1930-01-01

    Wenn man die gewaltige Menge Publikationen über das Volkslied, die im Laufe des 19. und 20. Jahrhunderts in Deutschland, Frankreich, Belgien und Holland erschienen sind, vergleicht, springen zwei Punkte sofort ins Auge: 1. der Unterschied zwischen den verschiedenen Auffassungen vom Begriff Volkslied

  11. Efficient radiologic diagnosis of pelvic and acetabular trauma; Rationelle bildgebende Diagnostik von Becken- und Azetabulumverletzungen

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F.; Mildenberger, P.; Thelen, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Rommens, P.M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2000-01-01

    In spite of the widespread availability of CT scanners, conventional X-ray radiographs remain the basic imaging modality in patients with pelvic and/or acetabular trauma. However, the extent of their use will depend on local utilities (e.g., availability of CT scanners) and on the patient's clinical condition. Regarding the inaccuracy of conventional radiography in the diagnosis of injuries of the dorsal pelvic ring and of the acetabulum, computed tomography represents the most important imaging modality in the clinically stable patient. CT provides an exact staging of the extent of trauma and allows for differentiation of pelvic instabilities. CT clearly demonstrates the severity of acetabular trauma and is superior in the detection of local complicating factors, i.e., impressions fractures and (sub-)luxations of the femoral head as well as free intraarticular fragments. CT findings provide the basis for definite treatment regimens of the injured patient. By extension of the examination, all relevant organs and systems (craniospinal, cardiovascular, gastrointestinal, respiratory, genitourinary) can be imaged during one session. The speed of spiral CT scanners and their diagnostic accuracy will play a major role in the management of, especially, polytraumatized patients. The indication for angiography with the option of therapeutic embolization exists if a pelvic bleeding persists even after reposition and operative fixation of the injury. (orig.) [German] Bei der Klaerung einer Verletzung des Beckens oder des Azetabulums stellen konventionelle Uebersichtsaufnahmen weiterhin die Basis der bildgebenden Diagnostik dar. Art und Umfang werden bestimmt von lokalen Gegebenheiten (z.B. Verfuegbarkeit von CT-Geraeten) sowie vom klinischen Zustand des Patienten. Aufgrund der diagnostischen Ungenauigkeit der konventionellen Roentgendiagnostik gerade im Bereich des stabilitaetsbedeutsamen dorsalen Beckenringes und des Azetabulums schliesst sich beim klinisch stabilen

  12. MDCT classification of osseous ankle and foot injuries; MDCT-Klassifikation knoecherner Verletzungen des oberen Sprunggelenks und des Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Opherk, J.P.; Rosenthal, H.; Galanski, M. [Medizinische Hochschule, Abteilung Diagnostische Radiologie, Hannover (Germany)

    2007-03-15

    Conventional radiography plays an essential role in the primary evaluation of acute ankle and foot trauma. In the case of complex injuries, however, subsequent computed tomography (CT) is nowadays recommended. In this connection, multidetector computed tomography (MDCT) allows better temporal, spatial, and contrast resolution compared with the conventional single-slice spiral CT. Multiplanar reformation and three-dimensional reconstruction of the acquired data sets are also helpful tools for critical assessment of therapeutic intervention. This report reviews the potential of the MDCT technique for accurate fracture classification, precise illustration of displaced components, and postoperative control of arrangement of typical lesions. (orig.) [German] Die konventionelle Radiographie spielt bei der initialen Diagnostik akuter Verletzungen des oberen Sprunggelenks und des Fusses eine essenzielle Rolle. Im Falle komplexer Frakturen ist jedoch eine weiterfuehrende computertomographische Diagnostik empfehlenswert. Dabei ist die Multidetektorcomputertomographie (MDCT) der konventionellen Einzeilencomputertomographie hinsichtlich Zeit-, Orts- und Kontrastaufloesung deutlich ueberlegen. Die multiplanare Reformation und dreidimensionale Rekonstruktion des akquirierten Datensatzes sind zudem bei der Beurteilung therapeutischer Interventionen aussagekraeftige Werkzeuge. Der vorliegende Beitrag gibt einen Ueberblick ueber die exakte Frakturklassifikation, die praezise Abbildung dislozierter Komponenten und die postoperative Stellungskontrolle typischer Verletzungen mit dieser Technik. (orig.)

  13. Ductal adenocarcinoma and unusual differential diagnosis; Duktales Adenokarzinom und ungewoehnliche Differenzialdiagnosen

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Schwartz, C.A.; Scharwaechter, C. [Universitaet Witten/Herdecke, Zentrum fuer Radiologie HELIOS Universitaetsklinikum Wuppertal, Wuppertal (Germany)

    2016-04-15

    Bildgebung eine entscheidende Rolle zu. Durch die weite Verbreitung bildgebender Verfahren werden jedoch gleichzeitig vermehrt inzidentelle Befunde im Pankreas entdeckt, die einer weiteren Abklaerung beduerfen. Das duktale Pankreaskarzinom kann von einer Vielzahl anderer Laesionen vorgetaeuscht werden, hierzu zaehlen anatomische Varianten, peripankreatische Strukturen oder Tumoren, seltenere primaere solide oder auch zystische Raumforderungen des Pankreas, Metastasen anderer Primaertumoren oder verschiedene Varianten von Pankreatitiden. Neben diesen Entitaeten sind zudem mehrere Vorlaeuferlaesionen des duktalen Pankreaskarzinoms differenzierbar. Eine Differenzierung dieser Erkrankungen von echten Pankreaskarzinomen ist insofern wichtig, als dass eine fruehe, korrekte Diagnosestellung fuer die Prognose wichtig ist und gleichzeitig die - ggf. vermeidbare - Therapie sehr einschneidend ist. Prinzipiell koennen alle bildgebenden Verfahren verwendet werden. Neben der meist am Anfang der Untersuchungskaskade stehenden Oberbauchsonographie sind dies v. a. die CT mit hervorragender Uebersichtlichkeit und guter Ortsaufloesung, die MRT mit guter Weichteildifferenzierung und der Moeglichkeit der Magnetresonanzcholangiopankreatikographie (MRCP), die Endosonographie mit hervorragender Ortsaufloesung, ggf. in Kombination mit einer endoskopisch retrograden Cholangiopankreatikographie (ERCP) oder der Moeglichkeit einer Biopsie, und auch die Positronenemissionstomographie(PET)-CT als molekulare Bildgebung. Die unterschiedlichen Verfahren bieten dabei jeweils Vor- und Nachteile und sollten je nach konkreter Fragestellung miteinander kombiniert werden. (orig.)

  14. Sound radiation contrast in MR phase images. Method for the representation of elasticity, sound damping, and sound impedance changes; Schallstrahlungskontrast in MR-Phasenbildern. Methode zur Darstellung von Elastizitaets-, Schalldaempfungs- und Schallimpedanzaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Radicke, Marcus

    2009-12-18

    The method presented in this thesis combines ultrasound techniques with the magnetic-resonance tomography (MRT). An ultrasonic wave generates in absorbing media a static force in sound-propagation direction. The force leads at sound intensities of some W/cm{sup 2} and a sound frequency in the lower MHz range to a tissue shift in the micrometer range. This tissue shift depends on the sound power, the sound frequency, the sound absorption, and the elastic properties of the tissue. A MRT sequence of the Siemens Healthcare AG was modified so that it measures (indirectly) the tissue shift, codes as grey values, and presents as 2D picture. By means of the grey values the sound-beam slope in the tissue can be visualized, and so additionally sound obstacles (changes of the sound impedance) can be detected. By the MRT images token up spatial changes of the tissue parameters sound absorption and elasticity can be detected. In this thesis measurements are presented, which show the feasibility and future chances of this method especially for the mammary-cancer diagnostics. [German] Die in dieser Arbeit praesentierte Methode kombiniert Ultraschalltechniken mit der Magnetresonanztomographie (MRT). Eine Ultraschallwelle ruft in absorbierenden Medien eine statische Kraft in Schallausbreitungsrichtung hervor. Die Kraft fuehrt bei Schallintensitaeten von einigen W/cm{sup 2} und einer Schallfrequenz im niederen MHz-Bereich zu einer Gewebeverschiebung im Mikrometerbereich. Diese Gewebeverschiebung haengt ab von der Schallleistung, der Schallfrequenz, der Schallabsorption und den elastischen Eigenschaften des Gewebes. Es wurde eine MRT-Sequenz der Siemens Healthcare AG modifiziert, so dass sie (indirekt) die Gewebeverschiebung misst, als Grauwerte kodiert und als 2D-Bild darstellt. Anhand der Grauwerte kann der Schallstrahlverlauf in dem Gewebe visualisiert werden, und so koennen zusaetzlich Schallhindernisse (Aenderungen der Schallkennimpedanz) aufgespuert werden. Mit den

  15. Malformations and abnormalities of the petrous portion of the temporal bone; Fehlbildungen und Missbildungen des Felsenbeins

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany); Heumueller, I. [Westpfalzklinikum Kaiserslautern, Institut fuer Radiologie, Kaiserslautern (Germany)

    2014-04-15

    High-resolution computed tomography (HRCT) is the procedure of choice in the diagnostics of abnormalities of the middle and inner ear. It allows a detailed presentation of anatomical features and achieves the prerequisites for selection of the various therapeutic options. The highly diverse abnormalities can be described using detailed imaging analyses. Malformations with an abnormally developed modiolus are assumed to be early embryological defects, such as the classical Mondini dysplasia. The essential therapeutic option for middle ear deformities is still a cochlear implant. The domain of magnetic resonance imaging (MRI) is not only in the analysis of the cochlear nerve and for exclusion of fibrosis or ossification of the labyrinth but is also able to visualize details of isolated malformations, such as an extended vestibular aqueduct or subtle alterations to the vestibule or can visualize them better in comparison to CT. Radiological diagnostics are used not only for classification but also to recognize typical clinical problem situations and play a key role in the diagnostics of hearing disorders and selection of the optimal therapeutic procedure. (orig.) [German] Die hochaufloesende CT ist das Verfahren der Wahl in der Diagnostik von Fehlbildungen des Mittel- und Innenohrs. Sie erlaubt die detaillierte Darstellung anatomischer Details und schafft die Voraussetzung fuer die unterschiedlichen Therapieoptionen. Durch detaillierte bildgebenden Analysen koennen die unterschiedlichsten Fehlbildungen beschrieben werden. Fehlbildungen mit einem nicht normal ausgebildeten Modiolus werden als fruehere embryologische Schaedigungen als die klassische Mondini-Dysplasie angesehen. Die wesentliche therapeutische Option bei Mittelohrfehlbildung bleibt das Kochleaimplantat. Die Domaene der MRT liegt nicht nur in der Analyse des N. cochlearis und im Ausschluss von Fibrosierungen oder Ossifikationen des Labyrinths, sondern darueber hinaus ist sie in der Lage, Details einzelner

  16. Tuberous sclerosis: Improvement of diagnosis by CT and MRI

    International Nuclear Information System (INIS)

    Dewes, W.; Henkes, H.; Richter, J.; Kretschmer, A.; Benz, P.; Brill, G.

    1992-01-01

    Ten children and a 22-y old women with tuberous sclerosis were studied. All children were epileptic but only 8 had skin lesions (white spots, adenoma sebaceum), 4 had rhabdomyoma of the heart and 4 children had strocytoma of the retina; only in 4 children was the entire triad of tuberous sclerosis seen. The young woman with a hemorrhage of an angiolipoma of the kidney had no other symptoms of tuberous sclerosis. All patients had pathologic CT and MRT findings; 4 different types of lesion were seen in MRT. In order to elucidate humangenetic aspects and to demonstrate the underlying disease all children with epileptic disorders and also all patients without the full triad of symptoms should be examined by MRT. (orig.) [de

  17. A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window

    International Nuclear Information System (INIS)

    Yu Hengyong; Ye Yangbo; Zhao Shiying; Wang Ge

    2005-01-01

    For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be applied for n-PI-window-based reconstruction in the nonstandard spiral scanning case. In this paper, we design an n-PI-window-based BPF algorithm, and report the numerical simulation results with the 3D Shepp-Logan phantom and Defrise disk phantom. The proposed BPF algorithm consists of three steps: cone-beam data differentiation, weighted backprojection and inverse Hilbert filtration. Our simulated results demonstrate the feasibility and merits of the proposed algorithm

  18. Fetal lung development on MRI. Normal course and impairment due to premature rupture of membranes; Fetale Lungenentwicklung in der MRT. Normaler Verlauf und Beeintraechtigung durch vorzeitigen Blasensprung

    Energy Technology Data Exchange (ETDEWEB)

    Kasprian, G. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik; Zentrum fuer Anatomie und Zellbiologie der Medizinischen Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie; Brugger, P.C. [Zentrum fuer Anatomie und Zellbiologie der Medizinischen Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie; Helmer, H.; Langer, M. [Medizinische Universitaet Wien (Austria). Klinik fuer Frauenheilkunde; Balassy, C.; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    A well-organized interplay between many molecular factors as well as mechanical forces influence fetal lung development. At the end of this complex process a sufficiently sized and structurally mature organ should ensure the postnatal survival of the newborn. Besides prenatal ultrasonography, magnetic resonance imaging (MRI) can now be used to investigate normal and pathological human lung growth in utero. Oligohydramnios, due to premature rupture of membranes (PROM), is an important risk factor for compromised fetal lung growth. In these situations MR volumetry can be used to measure the size of the fetal lung quite accurately. Together with the evaluation of lung signal intensities on T2-weighted sequences, fetuses with pulmonary hypoplasia can be readily detected. (orig.) [German] Die fetale Lungenentwicklung wird einerseits durch eine Vielzahl molekularer Faktoren und andererseits durch mechanisch-physiologische Kraefte beeinflusst. Ein geordnetes Zusammenspiel dieser Mechanismen fuehrt zu einem ausreichend grossen und strukturell reifen Organ, das sofort nach der Geburt das Ueberleben des Neugeborenen sicherstellt. Neben der praenatalen Ultraschalluntersuchung bietet nun auch die Magnetresonanztomographie (MRT) die Moeglichkeit, die normale und pathologische fetale Lungenentwicklung zu untersuchen. Ein wesentlicher Risikofaktor fuer eine Beeintraechtigung der Lungenentwicklung ist die verminderte Fruchtwassermenge nach vorzeitigem Blasensprung. In diesen Faellen kann die MR-Volumetrie dazu eingesetzt werden, die Groesse der fetalen Lungen relativ genau zu bestimmen. Gemeinsam mit der Beurteilung der MR-Signalintensitaeten des Lungengewebes auf T2-gewichteten Sequenzen koennen Feten mit hypoplastischen Lungen mit zunehmender Sicherheit bereits praenatal identifiziert werden. (orig.)

  19. Indications and technique of fetal magnetic resonance imaging; Indikationen und Technik der fetalen Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, U.; Woitek, R.; Furtner, J.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Brugger, P.C. [Medizinische Universitaet Wien, Zentrum fuer Anatomie und Zellbiologie, Wien (Austria)

    2013-02-15

    Evaluation and confirmation of fetal pathologies previously suspected or diagnosed with ultrasound. Ultrasound and magnetic resonance imaging (MRI). Technique for prenatal fetal examination. Fetal MRI is an established supplementary technique to prenatal ultrasound. Fetal MRI should only be used as an additional method in prenatal diagnostics and not for routine screening. Fetal MRI should only be performed in perinatal medicine centers after a previous level III ultrasound examination. (orig.) [German] Evaluierung und Bestaetigung von im praenatalen Ultraschall entdeckten Pathologien. Ultraschall und Magnetresonanztomographie. Praenatale Untersuchungsmethode. Die fetale MRT ist inzwischen als ergaenzende Methode zum praenatalen Ultraschall anerkannt. Die fetale MRT soll als additive Methode bei klinischer Relevanz, nicht jedoch als Routinescreeningverfahren waehrend der Schwangerschaft angewendet werden. Durchfuehrung ausschliesslich an einem Perinatalzentrum nach vorangegangenem Level-III-Ultraschall. (orig.)

  20. Fast reconstruction of industry CT image based on Wintel and P4 structure

    CERN Document Server

    Su Jian Ping; Zhang Li; Zhao Zi Ran; Gao Wen Huan; Kang Ke Jun

    2002-01-01

    Largescale I-CT is used to inspect large workpiece with high spiral resolution and its reconstructed image is very large. So it often relies on special workstation. Now with the development of P4 CPU and Windows2000, it is possible to reconstruct, deal and display I-CT image on Wintel structure. The authors discuss the possibility and future of this scheme. This is important for the improvement of economical value of I-CT

  1. Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction

    International Nuclear Information System (INIS)

    Naghibi, Saeed; Seifirad, Sirous; Adami Dehkordi, Mahboobeh; Einolghozati, Sasan; Ghaffarian Eidgahi Moghadam, Nafiseh; Akhavan Rezayat, Amir; Seifirad, Soroush

    2016-01-01

    Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients

  2. Recurrent pyogenic cholangitis: clinico-pathologic correlation of focal attenuation differences on multi-phasic spiral CT

    International Nuclear Information System (INIS)

    Jeong, Jun Yong; Han, Joon Koo; Kim, Tae Kyoung; Kim, Seog Joon; Kim, Hyun Bum; Choi, Byung Ihn

    2002-01-01

    To determine the clinical and the pathologic significance of the focal attenuation differences (FAD) and bile duct wall enhancement occurring in recurrent pyogenic cholangitis (RPC) and seen at multiphasic spiral CT. Among the multiphasic (non-contrast, arterial and portal or delayed phase) spiral CT findings of 60 consecutive patients, two types of FAD were noted during the non-contrast phase. These were Type A (iso) and Type B (low attenuation), and their distribution pattern (lobar versus patchy, multifocal) and the and the presence or absence of bile duct wall enhancement were recorded. The radiologic findings were correlated with the clinical and pathologic findings. Two types of FAD were noted in 40 of the 60 patients. Active in flammation was present in 19 of the 27 with Type-A and in ten of the 15 in whom the presence of RPC was pathologically proven. Ten of the 13 with Type-B FAD were in a subclinical state, and nine of the ten in whom RPC was pathologically proven had chronic inflammation. Among 20 patients who did not have FAD, RPC was subclinical in 18 and dormant in nine of the eleven in whom its presence was pathologically proven (p<0.001). Clinico-pathologic correlation with bile duct wall enhancement and the distribution pattern of FAD showed no statistical significance. The inflammatory activity of RPC can be predicted by analysis of the FAD seen at multiphasic spiral CT

  3. Imaging of the lumbosacral plexus. Diagnostics and treatment planning with high-resolution procedures; Bildgebung des Plexus lumbosacralis. Diagnostik und Therapieplanung mithilfe hochaufgeloester Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Jengojan, S.; Schellen, C.; Bodner, G.; Kasprian, G. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2017-03-15

    Technical advances in magnetic resonance (MR) and ultrasound-based neurography nowadays facilitate the radiological assessment of the lumbosacral plexus. Anatomy and imaging of the lumbosacral plexus and diagnostics of the most common pathologies. Description of the clinically feasible combination of magnetic resonance imaging (MRI) and ultrasound diagnostics, case-based illustration of imaging techniques and individual advantages of MRI and ultrasound-based diagnostics for various pathologies of the lumbosacral plexus and its peripheral nerves. High-resolution ultrasound-based neurography (HRUS) is particularly valuable for the assessment of superficial structures of the lumbosacral plexus. Depending on the examiner's experience, anatomical variations of the sciatic nerve (e. g. relevant in piriformis syndrome) as well as more subtle variations, for example as seen in neuritis, can be sonographically depicted and assessed. The use of MRI enables the diagnostic evaluation of more deeply located nerve structures, such as the pudendal and the femoral nerves. Modern MRI techniques, such as peripheral nerve tractography allow three-dimensional depiction of the spatial relationship between nerves and local tumors or traumatic alterations. This can be beneficial for further therapy planning. The anatomy and pathology of the lumbosacral plexus can be reliably imaged by the meaningful combination of MRI and ultrasound-based high resolution neurography. (orig.) [German] Durch technische Fortschritte im Bereich der magnetresonanz- (MR-) und ultraschallbasierten Neurographie ist der Plexus lumbosacralis heute der radiologischen Abklaerung zugaenglich. Anatomie und Bildgebung des Plexus lumbosacralis, Abklaerung der haeufigsten Pathologien. Erlaeuterung der klinisch sinnvollen Kombination von MR- und Ultraschalldiagnostik, Darstellung der Untersuchungstechniken und der jeweiligen Vorteile von MRT und Ultraschall anhand fallbasierter Praesentation unterschiedlicher

  4. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system

    International Nuclear Information System (INIS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2002-01-01

    The aim of this study was to evaluate a computer-aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Eighty-eight consecutive spiral-CT examinations were reported by two radiologists in consensus. All examinations were reviewed using a CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm is designed to detect nodules with diameters of at least 5 mm. A total of 153 nodules were detected with at least one modality (radiologists in consensus, CAD, 85 nodules with diameter <5 mm, 68 with diameter ≥5 mm). The results of automatic nodule detection were compared to nodules detected with any modality as gold standard. Computer-aided diagnosis correctly identified 26 of 59 (38%) nodules with diameters ≥5 mm detected by visual assessment by the radiologists; of these, CAD detected 44% (24 of 54) nodules without pleural contact. In addition, 12 nodules ≥5 mm were detected which were not mentioned in the radiologist's report but represented real nodules. Sensitivity for detection of nodules ≥5 mm was 85% (58 of 68) for radiologists and 38% (26 of 68) for CAD. There were 5.8±3.6 false-positive results of CAD per CT study. Computer-aided diagnosis improves detection of pulmonary nodules at spiral CT and is a valuable second opinion in a clinical setting for lung cancer screening despite of its still limited sensitivity. (orig.)

  5. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  6. Multi-slice spiral CT detects spread of small laryngeal tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Schoepf, U.; Becker, C.; Reiser, M.; Hong, C.; Sturm, C.; Wollenberg, B.

    1999-01-01

    The purpose of the study was to preoperatively investigate small laryngeal carcinomas using multi-slice spiral CT (MSCT) and subsequent multiplanar reconstructions (MPR) and to compare the results to the detailed spread found a surgery and histology. Nine patients with small (T1, T2) laryngeal cancer were investigated on a MSCT scanner (Siemens plus 4 Volume Zoom, Siemens). A 4x1 mm collimation, 120 kV, 200 mAs and a 0.5 seconds rotation time were used, allowing a coverage of the entire larynx in approximately 10 seconds within a single breathhold. Multiplanar reconstruction's (MPR) in sagittal and coronal plane were reconstructed in all patients and rated in consensus reading. In 8 of nine patients, the glottic spread was detected by MSCT, in one case of a supraglottic tumor a glottic invasion was excluded. The infiltration of the anterior commissure, the infiltration into the subglottic space and the extension into the hypo-pharynx was correctly assessed in all patients. MSCT was not able to predict infiltration of the arythnoids in two patients. The use of multi-slice CT for the preoperative assessment of small laryngeal tumors shows great promise. The detection or exclusion of subtle spread of these tumors into the supra- or subglottic space and along the glottic level was possible with high accuracy. As the examination time is short, artifacts are rare and multiplanar reconstructions gain in clinical importance. (orig.) [de

  7. Clinical neuroanatomy and diagnostic imaging and evaluation of the brain. MRI and CT atlas. 3. new rev. and enl. ed.; Klinische Neuroanatomie und kranielle Bilddiagnostik. Atlas der Magnetresonanztomographie und Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kretschmann, H.J. [Medizinische Hochschule Hannover (Germany); Weinrich, W. [Krankenhaus Nordstadt, Klinikum Hannover (Germany)

    2003-07-01

    New features of this 3rd German edition are: - Number of the MR and CT images almost doubled, all pictures now in large format, displaying much more brain structures. - New knowledge and insight incorporated in the text and pictures. (orig./CB) [German] In der vorliegenden 3. Auflage wurden die MR- und CT-Bilder des Bildatlas durch grossformatige Abbildungen ersetzt. Ihre Anzahl wurde nahezu verdoppelt. In den nun grossen Abbildungen konnte die Zahl der bezeichneten Hirnstrukturen wesentlich erhoeht werden. Neues Wissen wurde in den Text und in die Abbildungen aufgenommen. (orig./AJ)

  8. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  9. PET/CT和MSCT联合应用在孤立性肺结节诊断中的价值%PET-CT with multi-slice spiral CT in the diagnosis of SPN

    Institute of Scientific and Technical Information of China (English)

    汪世存; 方雷; 潘博; 展凤麟; 谢强; 谢吉奎

    2009-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射显像/电子计算机断层扫描成像(18F-deoxyglucose positron emission tomography /computer tomography 18F-FDG PET/CT)和多排CT( multi-slice spiral CT,MSCT)联合应用在孤立性肺结节(SPN)诊断中的价值.方法 87例SPN患者均行PET/CT及肺部病灶MSCT检查,影像诊断结果 与病理对照,进行统计分析.结果 87例SPN中,MSCT诊断正确64例,误诊23例,误诊率26.4%.PET/CT诊断正确70例,误诊17例,误诊率19.5%.MSCT和PET/CT联合诊断,80例诊断正确,7例误诊,误诊率8.0%.MSCT、PET/CT及两者联合诊断的敏感性、特异性和准确性分别为87.2%、68.1%、79.8%;89.5%、61.3%、81.4%和97.7%、74.2%、91.5%.MSCT和PET/CT单独诊断SPN的准确性无统计学意义(χ2=0.625,P=0.239),MSCT、PET/CT与两者联合应用诊断SPN的准确性均有统计学意义(χ2=7.762和5.318,P=0.005和0.021).结论 SPN的MSCT和PET/CT影像特征均有一定的重叠.单独采用MSCT或PET/CT诊断肺结节无明显统计学差异,MSCT和PET-CT协同诊断的准确性高于MSCT或PET/CT单独诊断.%Aim To evaluate the value of a combination of 18F-FDG PET-CT with multi-slice spiral CT in the diagnosis of SPN.Methods 18F-FDG PET-CT and multi-slice spiral CT were performed in 87 patients with SPN.The pathologically-proved findings were compared with findings diagnosed by MSCT and retrospectively analyzed.Results In 87 cases,the numbers of correct diagnosis and misdiagnosis with MSCT were 64 and 23 respectively,the misdiagnosis rate 26.4%,while the numbers of correct diagnosis and misdiagnosis with PET/CT were 70 and 17,the misdiagnosis rate 19.5%,but 50 cases were correctly diagnosed and 7 cases were misdiagnosed by combining 18F-FDG PET-CT with MSCT,the misdiagnosis rate 8.0%.The sensitivity,specificity,positive predictive value,negative predictive value,and accuracy of MSCT,PET/CT,and MSCT combined with PET /CT were 87.2%,68.1%,79.8%;89.5%,61.3%,81.4% and 97

  10. Conventional angiography in comparison with magnetic resonance tomography and arthroscopy for the diagnosis of knee joint lesion - specific indications?; Die konventionelle Arthrographie im Vergleich zu Magnetresonanztomographie und Arthroskopie bei Kniegelenkbinnenlaesionen: Verbleiben Indikationen?

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, H. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany); Andresen, R. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany); Radmer, S. [Orthopaedisches Institut, Berlin (Germany); Schmidt, M. [Krankenhaus Moabit, Roentgenabteilung, Berlin (Germany); Wolf, K.J. [Universitaetsklinikum Steglitz, Radiologische Klinik, Abt. fuer Roentgendiagnostik und Nuklearmedizin, FU Berlin (Germany)

    1995-03-01

    Twenty-one patients with suspected internal knee joint lesions were examined prospectively. In all patients an MRI was carried out first and was followed within two weeks by an arthrography and an arthrocopy. Lesions of the menisci, cruciate ligaments, hyaline cartilage, and synovial tissues were evaluated. Arthroscopy findings were defined as the `gold standard`. MRI achieved an accuracy of 96.4%, a sensitivity of 93.6%, and a specifity of 92.5%, whereas arthrography achieved an accuracy of 67.8%, a sensitivity of 66.6%, and a specifity of 71.4%. These statistical data as well as the single findings revealed no special indications for arthrography in suspected knee joint lesions. (orig.) [Deutsch] In einer prospektiven Studie wurden insgesamt 21 Patienten mit suspekten Kniegelenksbinnenlaesionen untersucht. Bei allen Patienten erfolgte zunaechst eine Magnetresonanztomographie (MRT), anschliessend innerhalb von zwei Wochen eine Arthrographie und Arthroskopie des Kniegelenks. Beurteilt wurden Laesionen der Meniski, der Kreuzbaender, des hyalinen Gelenkknorpels und des Synovialgewebes. Bezogen auf den Arthroskopiebefund als `Gold-Standard` erreichte die MRT eine Treffsicherheit von 96,4%, eine Sensitivitaet von 93,6% und eine Spezifitaet von 92,5%; dagegen die Arthrographie eine Treffsicherheit von 67,8%, eine Sensitivitaet von 66,6% und eine Spezifitaet von 71,4%. Sowohl eine Uebersicht als auch die Auswertung der Einzelbefunde ergaben keine speziellen Indikationen zur Durchfuehrung einer Kniegelenksarthrographie bei suspekten Binnenlaesionen. (orig.)

  11. Magnetic resonance imaging of the hand in rheumatoid arthritis. New scientific insights and practical application; Magnetresonanztomographie der Hand bei rheumatoider Arthritis. Wissenschaftliche Ergebnisse und praktische Anwendung

    Energy Technology Data Exchange (ETDEWEB)

    Hermann, K.G.A. [Charite - Universitaetsmedizin Berlin, Institut fuer Radiologie am Campus Mitte, Berlin (Germany)

    2006-05-15

    Magnetic resonance imaging (MRI) is a sensitive diagnostic modality for the detection of inflammatory changes in peripheral joints. Nevertheless, the widespread clinical use of MRI in assessing patients with early rheumatoid arthritis is still hampered by the technical complexity and higher cost of MRI compared with conventional radiography. This overview summarizes the results of recent research and gives practical tips on how to perform MRI of the hands. The authors present an MR protocol for hand imaging, discuss the pros and cons of low-field MR scanners, and outline pitfalls and artifacts. The MRI changes associated with rheumatoid arthritis such as synovitis, tenosynovitis, erosions, and bone marrow edema are described including their prognostic significance. The proven facts on the validation and grading of MR changes in rheumatoid arthritis are summarized. Finally, the role of MRI in the differential diagnosis of arthritis is critically discussed. (orig.) [German] Die Magnetresonanztomographie (MRT) ist ein sensitives Verfahren zur Detektion entzuendlicher Veraenderungen der peripheren Gelenke. Den breiten Einsatz der MRT im Fruehstadium der rheumatoiden Arthritis behindern derzeit jedoch der im Vergleich zur konventionellen Roentgendiagnostik hoehere technische Aufwand und vermehrte Kosten. Diese Uebersichtsarbeit fasst wichtige Studienergebnisse zusammen und gibt praktische Hinweise fuer Hand-MRTs. Ein geeignetes Sequenzprotokoll wird vorgestellt, Vor- und Nachteile von Niederfeld-MRTs werden beruecksichtigt, moegliche Fehlerquellen und Artefakte diskutiert. Magnetresonanztomographische Befunde bei rheumatoider Arthritis wie Synovitis, Tenosynovitis, Erosionen und Knochenmarkoedeme werden beschrieben und deren prognostische Bedeutung dargestellt. Gesicherte Fakten zur Validierung und Moeglichkeiten der Graduierung MR-tomographischer Veraenderungen bei rheumatoider Arthritis werden zusammengefasst. Der Nutzen der MRT zur differenzialdiagnostischen

  12. Functional MRI and neurophysiological aspects of obesity; Funktionelle MRT und neurophysiologische Aspekte der Adipositas

    Energy Technology Data Exchange (ETDEWEB)

    Sztrokay, A.; Reiser, M.; Meindl, T. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Gutyrchik, E. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Medizinische Psychologie, Muenchen (Germany)

    2011-05-15

    Functional magnetic resonance imaging studies have revealed that metabolic signals and food stimuli activate the mesocorticolimbic neural network involved in processing the reward system. Activation is influenced by obesity and hunger and many recent brain imaging studies have detected that food and drug stimuli activate many of the same reward circuits. These findings have implications for obesity prevention and therapy. Educational efforts need to be directed towards those at increased risk of becoming obese and the food industry has to be involved in providing and promoting healthier food options. Given that visual food stimuli are potent triggers of desire, seductive advertising of high calorie foods directed towards children should be curtailed. The application of non-invasive brain imaging methodologies to the study of hedonic and homeostatic eating behavior represents a novel and important experimental approach. Further advances in imaging technology and improved experimental designs will provide new and important insights into human ingestive behavior that may lead to new developments in behavioral and pharmacological therapies. (orig.) [German] Bildgebende Studien zeigen, dass Nahrungsreize und metabolische Stimuli das mesokortikolimbische System und somit das Belohnungssystem aktivieren. Die Aktivierung dieses Systems wird sowohl von Hunger als auch Uebergewicht beeinflusst. In bildgebenden Studien wurde nachgewiesen, dass Reize in Form von Essen aehnlich wie Suchtmittel den Belohnungskreislauf aktivieren. Diese Erkenntnis hat Auswirkungen auf die Praevention und Therapie der Adipositas. Die Nahrungsmittelindustrie ist gefordert, gesuenderes Essen zu produzieren und entsprechend zu bewerben. Vor dem Hintergrund, dass die visuelle Stimulation durch Nahrungsmittel ein potenzieller Trigger fuer das Verlangen nach Essen ist, sollte die direkt auf Kinder ausgerichtete Bewerbung hochkalorischer Nahrungsmittel reduziert werden. Die Anwendung nichtinvasiver

  13. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT

    International Nuclear Information System (INIS)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W.; Koester, M.

    1999-01-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [de

  14. The application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement

    International Nuclear Information System (INIS)

    Wei Ning; Xu Hao; Zu Maoheng; Gu Yuming; Li Gang; Zhang Qingqiao; Xu Wei; Cui Yanfeng; Liu Hongtao; Wang Wenliang

    2012-01-01

    Objective: To evaluate the application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement. Methods: Thirty-one patients treated with tracheal stents were retrospectively analyzed, of which there were 27 malignant tracheal stenosis, 2 benign tracheal stenosis, 1 bronchial remnant fistula and 1 gastroesophageal anastomosis tracheal fistula. The spiral-CT and 3D-imagings were analyzed and the location, shape and complication of the stents were assessed. Results: Thirty-one patients were treated with 8 Z-type stainless steel stents and 28 Ni-Ti memory alloy stents. The stents of 22 cases remained patent in the original position and restenosis was occurred in 5 cases, migration in 3 cases and fracture in 1 case. All the CT features were performed and reconstructed on the workstation, using multiplanar reconstruction, volume rendering, and CT virtual endoscopy. The location of tracheal stenosis and fistula were showed in different angle, and the location, shape of the stents, and the complications (such as restenosis, fracture) as well. Conclusion: Spiral-CT and 3D-imaging is a rapid, simple and effective method in assessing tracheal stent implantation and complication, therefore, it is of great value in clinical practice. (authors)

  15. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    International Nuclear Information System (INIS)

    Reissig, Angelika; Heyne, Jens-Peter; Kroegel, Claus

    2004-01-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli

  16. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    Energy Technology Data Exchange (ETDEWEB)

    Reissig, Angelika E-mail: angelika.reissig@med.uni-jena.de; Heyne, Jens-Peter; Kroegel, Claus

    2004-03-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli.

  17. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  18. Characterization of adrenal masses: can image replace biopsy?; Charakterisierung von Nebennierenraumforderungen. Kann die Bildgebung die Biopsie ersetzen?

    Energy Technology Data Exchange (ETDEWEB)

    Heinz-Peer, G.; Hoenigschnabel, S.; Lechner, G. [Universtaetsklinik fuer Radiodiagnostik, Abt. Chirurgische Faecher, Wien (Austria)]|[Ludwig Boltzmann-Inst. fuer Radiologische Tumorforschung, Wien (Austria); Niederle, B. [Universitaetsklinik fuer Chirurgie, Univ. Wien (Austria)

    1999-07-01

    This paper describes the diagnostic value of new imaging techniques in characterization of adrenal masses and evaluates the role of adrenal biopsy. For differentiation of benign and malignant adrenal lesions, sensitivities and specificities of 85-100% can be reached by unenhanced computed tomography (CT) methods, chemical shift techniques in magnetic resonance imaging (MRI), delayed enhanced CT techniques, and by evaluation of wash-out curves in contrast-enhanced CT. The diagnostic value of all CT techniques depends on threshold values. The value of dynamic contrast-enhanced MRI is under discussion and should be reevaluated by using delayed enhance series. Biochemical and scintigraphic methods (NP 59 iodine iodomethyl-norcholesterol and MIBG meta-iodobenzylguanidine scintigrams) are valuable for the diagnosis of functional adrenal masses; however, they do not allow differentiation of benign and malignant tumors. According to excellent results of new imaging techniques in characterization of adrenal masses, the indications for fine-needle aspiration biopsy have already regressed, as have complications associated with this invasive technique. (orig.) [Deutsch] Diese Arbeit beschreibt die Moeglichkeiten der Charakterisierung von Nebennierenlaesionen durch die Bildgebung von neuen Untersuchungstechniken und evaluiert den geaenderten Stellenwert der Nebennierenbiopsie. Mittels der nativen Computertomographie (CT), der Chemical-Shift-Technik der Magnetresonanztomographie (MRT) oder Dichtemessungen in CT-Kontrastmittelspaetserien bzw. der Bestimmung des prozentuellen Dichteverlustes in CT-Kontrastmittelserien koennen in der Differenzierung von benignen und malignen Nebennierenlaesionen Sensitivitaeten und Spezifitaeten von 85%-100% erreicht werden. Die diagnostische Wertigkeit der CT-Techniken ist abhaengig von der Definition eines Schwellenwertes. Die Wertigkeit der dynamischen KM-verstaerkten MRT wird derzeit unterschiedlich beurteilt und sollte anhand verbesserter

  19. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  20. Assessment of hemodynamics in a rat model of liver cirrhosis with precancerous lesions using multislice spiral CT perfusion imaging.

    Science.gov (United States)

    Ma, Guolin; Bai, Rongjie; Jiang, Huijie; Hao, Xuejia; Ling, Zaisheng; Li, Kefeng

    2013-01-01

    To develop an optimal scanning protocol for multislice spiral CT perfusion (CTP) imaging to evaluate hemodynamic changes in liver cirrhosis with diethylnitrosamine- (DEN-) induced precancerous lesions. Male Wistar rats were randomly divided into the control group (n = 80) and the precancerous liver cirrhosis group (n = 40). The control group received saline injection and the liver cirrhosis group received 50 mg/kg DEN i.p. twice a week for 12 weeks. All animals underwent plain CT scanning, CTP, and contrast-enhanced CT scanning. Scanning parameters were optimized by adjusting the diatrizoate concentration, the flow rate, and the delivery time. The hemodynamics of both groups was further compared using optimized multislice spiral CTP imaging. High-quality CTP images were obtained with following parameters: 150 kV; 150 mAs; 5 mm thickness, 5 mm interval; pitch, 1; matrix, 512 × 512; and FOV, 9.6 cm. Compared to the control group, the liver cirrhosis group had a significantly increased value of the hepatic arterial fraction and the hepatic artery perfusion (P spiral CTP imaging can be used to evaluate the hemodynamic changes in the rat model of liver cirrhosis with precancerous lesions.

  1. Diagnosis and staging of carcinoma localized in the antral part of the stomach with spiral CT

    International Nuclear Information System (INIS)

    Pomakov, P.; Grudeva, V.; Mlachkova, D.

    2009-01-01

    The aim of the study was to characterize CT images and stages of carcinomas localized in the antral part of the stomach obtained with spiral CT. Seven men aged from 54 years old to 81 years old inclusive, with subjective complaints and clinical suspicion of a neoplasm in the upper gastrointestinal tract were examine Examinations were performed following stomach wall re relaxation with Buscolysin.The stomach is distended by drinking 600 ml of water. Upper abdomen scans were performed with spiral CT/e General Electric with the following parameters: slice thickness 3-5 mm, spacing 3 mm, pitch 1,5, reconstruction index 3 mm. After the pre-contrast scans, 100 ml of non-ionic contrast media is administered intravenously with an injection rate of 30 ml/sec. Scan delay time - 30 seconds after start of injection. Exposition data-120 kV, 180 mAs. Carcinoma localized in the antral part of the stomach was demonstrated in 7 patients. The staging showed: I stage - one patient, II stage - 2, III stage - 1 and IV stage - three patients. According to the macro morphological characteristic: exophytic type - 4, endophytic tumor - 1, ulcerous tumor - 1 and early carcinoma - 1 patient. In our material only male patients were present. Early carcinoma was demonstrated in a male patient at an age of 80 years old. An enhancing nodular local thickness was visualized. Differential diagnosis between malignant and benign ulcer is necessary in certain cases. It is performed on the contrast scans, the malignant process enhances twice its density, When performing a purposive CT examination it is possible to diagnose neoplasms in the antral part of the stomach, from stage i to IV with different macro morphologic characteristic

  2. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    Directory of Open Access Journals (Sweden)

    Holger Wenz

    2016-01-01

    Conclusions: Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.

  3. MRI for therapy planning in patients with atrial septum defects; MRT zur Therapieplanung bei Patienten mit Vorhofseptumdefekt

    Energy Technology Data Exchange (ETDEWEB)

    Huber, A.; Rummeny, E. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Institut fuer Radiologie, Muenchen (Germany); Prompona, M.; Reiser, M.; Theisen, D. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Kozlik-Feldmann, R. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Kinderkardiologie, Muenchen (Germany); Muehling, O. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Medizinische Klinik I, Muenchen (Germany)

    2011-01-15

    The aim of this study was to determine the value of a combined magnetic resonance imaging (MRI) protocol including steady-state free precession (SSFP) imaging, phase-contrast measurements and contrast-enhanced MR angiography (CE-MRA) for presurgical or preinterventional diagnostic imaging in patients with suspected atrial septum defects. Out of 65 MRI studies of patients with suspected atrial septum defects, 56 patients were included in the study. The atrial septum defects were identified on cine images. Velocity encoded flow measurements were used to determine shunt volumes, which were compared with invasive oxymetry in 24 patients. Contrast-enhanced MRI was used to assess the thoracic vessels in order to detect vascular anomalies. The findings were compared with the intraoperative results. A total of 24 patients with high shunt volumes were treated either surgically (16 patients) or interventionally (8 patients) and 32 patients with low shunt volumes did not require surgical or interventional treatment. The vascular anomaly, which in all cases was anomalous pulmonary venous return, was confirmed by the intraoperative findings. The type and location of atrial septal defects which required treatment, were confirmed intraoperatively or during the intervention. The results of shunt quantification by MRI showed a good correlation with the results of invasive oximetry (r=0.91, p <0.0001). A combined MRI protocol including cine SSFP images, velocity-encoded flow measurements and CE-MRA is an accurate method for preoperative and preinterventional evaluation of atrial septum defects. (orig.) [German] Ziel war es, die Wertigkeit eines kombinierten MRT-Protokolls aus Funktionsuntersuchung, Flussmessung und MR-Angiographie zur praeoperativen oder -interventionellen Abklaerung bei Patienten mit Vorhofseptumdefekt zu evaluieren. Ingesamt wurden 56 Patienten mit Vorhofseptumdefekt aus einem Kollektiv von 65 Patienten mit Verdacht auf Vorhofseptumdefekt, die im MRT untersucht

  4. Spiral CT of the pancreas. The value of small field-of-view targeted reconstruction

    International Nuclear Information System (INIS)

    Nishiharu, T.; Yamashita, Y.; Ogata, I.; Sumi, S.; Mitsuzaki, K.; Takahashi, M.

    1998-01-01

    Purpose: To compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases. Material and methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols. Results: The high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). In patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details. Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities. (orig.)

  5. Spondylolysis in adolescents: the diagnostic value of MRI; Die Spondylolyse im Stadium der Entstehung: Diagnostischer Beitrag der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Staebler, A.; Steinborn, M.; Matzko, M.; Reiser, M. [Klinikum Grosshadern, Muenchen (Germany). Inst. fuer Radiologische Diagnostik; Paulus, R.; Bosch, R. [Muenchen Univ. (Germany). Orthopaedische Klinik

    2000-01-01

    Purpose: To assess the value of MR imaging in demonstrating ongoing spondylolysis in adolescents. Methods: MRI was performed in 9 juvenile patients (3 female, 6 male aged 8-16 years; mean 12.5 y) with pain during hyperextension. In 6 patients a CT scan and in 5 a plain film was available. Results: In all patients bone marrow edema was found in the pars interarticularis and the pedicle, which was bilateral in 4 patients. In 7/9 cases the L5 vertebra was affected, in 2/9 cases spondylolysis was found in L4. In 3 cases the edema reached the middle third of the vertebral body and a tumor was suspected. In all CT scans a bilateral incomplete or complete cleft in the pars interarticularis was found. In 4/6 CT-scans a sclerosis was seen in the area of the bone marrow edema. Only in 1/5 pain films was there a suspicion for a spondylolysis, four examinations were completely normal. Conclusions: To eliminate underlying causal conditions of spondylolysis and to install specific therapy, early diagnosis is mandatory. MR imaging should be the first and only imaging modality in young patients with low back pain during and after exercise and pain with hyperextension. Bone scans and CT scans should be avoided due to irradiation, plain films usually do not reveal pathological findings in developing spondylolysis. (orig.) [German] Ziel: Darstellung der Wertigkeit der MR-Tomographie in der Diagnostik der Spondylolyse im Stadium der Entstehung. Methoden: 9 sportlich, aktive jugendliche Patienten im Alter von 8-16 Jahren (Durchschnitt 12,5 Jahre) mit Rueckenschmerzen bei der Hyperextension wurden MR-tomographisch untersucht. In 6 Faellen lag eine CT, in 5 Faellen Roentgenaufnahmen vor. Ergebnisse: Bei den 9 Jugendlichen wurden Knochenmarkoedeme in der Pars interarticularis und den Bogenwurzeln nachgewiesen, die in 4 Patienten beidseitig vorhanden waren. In 7/9 Faellen war LWK 5 betroffen, in 2/9 LWK 4. In 3 Faellen reichte das Oedem in die Wirbelkoerper, bei 2 Patienten bestand

  6. Use of spiral CT in demonstrating early carcinoma of the stomach - I stage

    International Nuclear Information System (INIS)

    Pomakov, P.

    2009-01-01

    Full text: The aim of this lecture is to provide practical information about the methodology and technique of spiral computed tomography, which provide maximum diagnostic efficiency in early gastric cancer - I stage, and to present the semiotics of CT images seen in early gastric cancer stage I - a own and literature data. Methodology of the study covers optimal drug muscle relaxation of the abdominal wall by injection of 2 sg buskolizin intravenous; maximum distension of the stomach lumen by ingestion of 3 effervescent disintegrated tablets Vit. C with 1-2 sips of water, necessarily using of non-ionic contrast media - 100 ml / 300 mg iodine / 1 ml liquid bolus introduced for 30 seconds. Start scanning - 30 seconds of the start of injection - to visualize the arterial phase, use of slices with a thickness of 3 mm and 2 mm interval; exponential data 120 kV, 160 mAc. Earlier form of gastric cancer have to be presented by 5 CT image: unequal unsmooth, scallop or polycyclic contours of the lining, thinning the complete disappearance of the lining; undulating thickening of the lining; nodal formation like a polyp on a broad basis with a 2-5 mm, double contour of the lining - like a wave. These amendments are localized only in a limited segment of the gastric mucosa. Spiral CT is an effective diagnostic performance in gastric cancer, including the early stage I of cancer development. This is realized only by using the specific methodology of the study as well as good knowledge of the CT images semiology for carcinoma, localized only within a certain perimeter of the stomach lining

  7. A standardized CT/HRCT classification for occupational and environmental lung diseases of the German Federal Republic; Standardisierte CT/HRCT-Klassifikation der Bundesrepublik Deutschland fuer arbeits- und umweltbedingte Thoraxerkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Hering, K.G. [Radiologische Klinik, Knappschaftskrankenhaus Dortmund (Germany); Tuengerthal, S. [Roentgenabteilung, Thoraxklinik Heidelberg (Germany); Kraus, T. [Institut fuer Arbeitsmedizin, Universitaetsklinikum Aachen (Germany)

    2004-05-01

    unerlaesslicher Bestandteil der Diagnostik von Staublungenerkrankungen und anderen Inhalationsschaeden. Konsensfaehige Vereinbarungen ueber eine standardisierte Untersuchungstechnik und einheitliche Befundung existierten bislang aber nicht. Von der Arbeitsgemeinschaft ''Diagnostische Radiologie bei arbeits- und umweltbedingten Erkrankungen'' der Deutschen Roentgengesellschaft (DRG) wurde ein CT-Beurteilungsbogen eingesetzt, der auf Erfahrungen aus gutachtlichen Stellungnahmen, arbeitsmedizinischen nachgehenden Untersuchungen und Fortbildungskursen basiert und im Rahmen einer Multicenterstudie eingesetzt wurde. Ein weiter entwickeltes Schema einer internationalen Arbeitsgruppe (P.A. Gevenois, Belgien; K.G. Hering, T. Kraus, S. Tuengerthal, Deutschland; L. Kivisaari, T. Vehmas, Finnland; M. Letourneux, Frankreich; M.D. Crane, Grossbritannien; H. Arikawa, Y. Kusaka, N. Suganuma, Japan; J. Parker, USA) wurde international getestet. Es soll dazu dienen, die computertomographische Befundung der arbeits- und umweltbedingten Lungen- und Pleuraveraenderungen zu standardisieren und international Vergleiche zu ermoeglichen. Mit Hilfe von CT/HRCT-Referenzfilmen konnte diese reproduzierbare Vergleichbarkeit erreicht werden. Das Klassifizierungsschema hat einen rein deskriptiven Charakter, sodass alle Aspekte arbeits- und umweltbedingter Folgeerscheinungen an Parenchym und Pleura erfasst werden koennen. Obwohl einige der deskriptiven Bezeichnungen mit pneumokoniotischen Befunden verknuepft sind, wie z. B. rundliche Herde mit der Silikose oder interlobulaere septale und intralobulaere nichtseptale Linien sowie ''honeycombing'' mit der Asbestose, finden sich zahlreiche ueberlappende Bildmuster, die differenzialdiagnostisch zu diskutieren sind. (orig.)

  8. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  9. Three-Dimensional post-myelographic CT reconstruction in the diagnosis and therapy planning for spinal development disorders; Dreidimensionale postmyelographische CT-Rekonstruktion in der Diagnostik und Therapieplanung spinaler Entwicklungsstoerungen

    Energy Technology Data Exchange (ETDEWEB)

    Wicht, L. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Benndorf, G. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Beier, J. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany); Haberl, H. [Neurochirurgische Abt., Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Virchow Klinikum, Humboldt-Univ. zu Berlin (Germany)

    1996-05-01

    Dysrhaphia is often associated with severe osseous aberrations of the spine such as, for example scoliosis, hemivertebra, and synostosis. With the advanced possibilities of the post-processing of CT-data (segmentation, three-dimensional reconstruction), post-myelo-CT is an excellent method for the evaluation of osseous structures and the myelon in preoperative planning. (orig.) [Deutsch] Dysraphien gehen haeufig mit ausgepraegten ossaeren Veraenderungen der Wirbelsaeule wie Skoliose, Halbwirbelbildungen und Synostosen einher. Mit den verbesserten Moeglichkeiten der Datennachbearbeitung (Segmentierung, 3D-dimensionale Rekonstruktion) stellt die postmyelographische Computertomographie vor allem bei komplexen Fehlbildungen ein geeignetes Verfahren zur praeoperativen Beurteilung der ossaeren Strukturen der Wirbelsaeule und des Myelons dar. (orig.)

  10. Clinical dictionary of MRT

    International Nuclear Information System (INIS)

    Herborn, C.U.; Zink, C.

    2007-01-01

    MRT is the method of choice in many clinical problems. It is also one of the most complex imaging procedures, requiring much technical and physical knowledge and also detailed knowledge of the signal response of physiological and pathological tissues in the many variants of contrast enhancement, image reconstruction and image processing. In 2006, the pocket dictionary of MRT was published by the same publisher. It met with much positive response, which induced the publication of this new dictionary. With more than 3000 terms and definitions elaborated in cooperation with an excellent practician, the clinical applications of MRT are illustrated by typical findings and examples. (orig.)

  11. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  12. Motion estimation and compensation in dynamic spiral CT reconstruction

    International Nuclear Information System (INIS)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St.

    2004-01-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  13. Clinical application of 3D spiral CT of the auditory ossicular chain and labyrinth: Preliminary report

    International Nuclear Information System (INIS)

    Huang Yong; Wang Yisheng

    1998-01-01

    Purpose: To assess the clinical application and limitation of 3D spiral CT of the auditory ossicular chain and labyrinth. Methods: 3D reconstruction of the auditory ossicular chain and labyrinth, including multiplanar reformation (MPR), minimum or maximum intensity projection (MinIP or MaxIP) and shaded surface display (SSD), were performed with 1 mm slice thickness, 5 cm field of view and 0.1 mm reconstruction interval spiral CT in 14 normal subjects, 15 patients with middle ear diseases. Results: With use of 3D reconstruction images in 14 normal subjects, 13 cases of ossicular chain showed that the long process of the incus was parallel to the manubrium and projected inferomedian toward the cochlear promontory, the incus-stapedial joint was like a 'L-shape' structure, and in 8 cases of labyrinth reconstruction, the cochlea and the three semicircular canals were demonstrated. 9 cholesteatomas of 13 chronic otitis media demonstrated destruction of ossicular chain of varying degrees. In 2 cases with congenital abnormality, ossicle dysplasia was seen. Conclusion: 3D CT is a useful technique for evaluating anatomic malformations and diseases of middle and inner ear, but there are still few pitfalls

  14. Accuracy of spiral CT and 3D reconstruction in the detection of acute pulmonary embolism - development of an animal model using porcine lungs and technical specimens. Development of an animal model using porcine lungs and technical specimens

    International Nuclear Information System (INIS)

    Ries, B.G.; Kauczor, H.U.; Thelen, M.; Konerding, M.A.

    2001-01-01

    Purpose: To develop a model for simulation the CT morphologic situation of acute pulmonary embolism, to evaluate the accuracy of spiral CT and 3D reconstruction in the detection of artificial emboli and to investigate the influence of the orientation of emboli depending on z-axis orientation. Materials and Methods: Standardized artificial emboli made of wax and of defined size and shape were positioned into the pulmonary arteries of porcine lungs. Castings of the embolized pulmonary arterial trees were made by injection of a special opaque resin. After performance of spiral CT the data sets of the emboli and the pulmonary arteries were post-processed. The 3D segmentations were compared with the anatomic preparation to evaluate the accuracy of spiral CT/3D reconstruction-technique. Technical specimens simulating CT-morphology of acute embolized vessels underwent spiral CT in six different positions with respect to the z-axis. The CT data were reconstructed using a standardized and a contrastadapted method with interactive correction. The 3D emboli were analysed under qualitative aspects, and measurements of their extent were done. Results: In nearly 91%, there was complete agreement between CT and the corresponding findings at the anatomical preparation. Measurements of the 3D reconstructed technical specimens showed discrepancies of shape and size in dependence of the size of the original preparation, orientation and reconstruction technique. Overestimation up to 4 mm and underestimation to 2,2 mm were observed. Measurements of preparations with heights from 14 to 26 mm showed variances of ±1,5 mm (∝6-11%). Conclusion: The presented models are suitable to simulate CT morphology of acute pulmonary embolism under ex-vivo conditions. Accuracy in the detection of artificial emboli using spiral CT/3D reconstruction is affected by localization, size and orientation of the emboli and the reconstruction technique. (orig.) [de

  15. The spiral CT manifestations of the blood supply of primary hepatocellular carcinoma: correlation with pathological findings

    International Nuclear Information System (INIS)

    Huang Juan; Zhou Xiangping; Liu Rongbo; Chen Xian; Xu Chongyong; Yan Zhihan; Xu Jianying

    2000-01-01

    Objective: To study the correlation between the CT features of tumor blood supplies and the pathological changes in primary hepatocellular carcinoma (PHCC). Methods: Fifty cases with surgically and pathologically proved PHCC underwent spiral CT scanning (plain + dual-phase). One research group blindly evaluated the CT films obtained. According to tumor contrast enhancement and signals showed on CT, the patterns of PHCC was divided into 4 types: arterial blood supplying, portal blood supplying, arterial combining with portal blood supplying, and poorly blood supplying. Microscopically, PHCC was respectively classified into grade I to IV with Edmonson's standard, and into 4 types (trabecular, pseudo-glandular, compact, scirrhous) with WHO histological grading standard. At last, the CT features of tumor blood supplies were correlated with pathologic changes. Results: 36(72%) cases were supplied by hepatic arterial blood, 6(12%) by arterial combining with portal blood supplying, 4(8%) by portal, and 4(8%) were poorly blood supplying. The patterns of tumor blood supplies in PHCC correlated with tumor cells differentiation (P<0.05). PHCC with better tumor cells differentiation was more associated with portal blood supplies. The patterns of tumor blood supplying in PHCC correlated with the histological type of the tumor cell (P < 0.05). All of the scirrhous PHCC were lack of blood supplies, the entire compact and most of the trabecular PHCC were supplied by a arterial blood. Conclusion: The most of PHCC were supplied by hepatic arterial blood and others were supplied by portal blood, arterial combining with portal blood or lack of blood supplies. Evaluation of tumor blood supplies in PHCC is considered to be useful in differential diagnosis and treatment of PHCC

  16. Osseous abnormalities and CT findings in stueve-wiedemann-syndrome (SWS); Ossaere Manifestationen und CT-Befunde bei der seltenen Skelettdysplasie Stueve-Wiedemann (SWS)

    Energy Technology Data Exchange (ETDEWEB)

    Langer, R. [UAE University, Dept. of Radiology, Al Ain (United Arab Emirates); Al-Gazali, L. [UAE University, Dept. of Paediatrics (United Arab Emirates); Haas, D. [FMHS - UAE Univ. and Tawam Hospital - Dept. of Radiology (United Arab Emirates); Raupp, P.; Varady, E. [Dept. of Paediatrics Al Ain (United Arab Emirates)

    2004-02-01

    Purpose: analysis of typical conventional radiological and CT findings in our group of patients with the rare skeletal dysplasia Stueve-Wiedemann-Syndrome (SWS) and comparison with published data. Materials and methods: in 16 newborns with clinically dysmorphic features, dwarfism, and bowed limbs, radiographs of the chest and skeleton were obtained for classification of the underlying skeletal dysplasia. For the first time, computed tomography was performed for further investigation of midface hypoplasia. The early diagnosis of SWS could be made by correlation of the radiological and clinical findings. For evaluation of progression, follow-up radiological examinations of the skeleton were performed in four children surviving infancy. Results: clinically, the newborns with SWS showed dwarfisms, midface hypoplasia, bowed extremities with contractures and had severe problems with respiration, feeding, and swallowing as well as episodes of hyperthermia. Skeletal radiographs revealed bowing of the long tubular bones, most pronounced at the lower extremities. Additional findings were internal triangular cortical diaphyseal thickening at the concave side of the bowing, wide metaphyses with abnormal trabecular pattern and radiolucencies. Four patients survived infancy. Clinically, they suffered from recurrent aspiration pneumonia and recurrent episodes of hyperthermia as well as form cutaneous and mucosal infections. The follow-up radiographs showed progressive bowing of the long tubular bones as well as progressive metaphyseal decalcification. Conclusions: skeletal abnormalities in SWS are so characteristic that an early post partum diagnosis can be made. However, a close cooperation between radiologists, clinicians, and geneticists is required for correlation of clinical and radiological findings. The few cases that survive infancy have progressing orthopaedic problems. (orig.) [German] Ziel: Die typischen radiologischen und CT-Befunde beim kongenitalen Stueve

  17. Imaging of postarthroscopic complications after knee injuries; Bildgebung postarthroskopischer Komplikationen nach Knieverletzungen

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, C. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und muskuloskelettale Radiologie, Klinik fuer Radiodiagnostik, Wien (Austria); Skrbensky, G. von [Medizinische Universitaet Wien, Klinik fuer Orthopaedie, Wien (Austria)

    2012-11-15

    The most common joint injuries in professional and recreational sports participants and also in the total population are knee injuries. Arthroscopy is indicated if this modality will improve the patient outcome and potential long-term complications can be avoided. Although uncommon, complications following arthroscopy are mostly evaluated by magnetic resonance imaging (MRI). For planning further therapy strategies following postarthroscopic complications, e.g. if anterior cruciate ligament (ACL) reconstruction is required, digital radiographs and computed tomography (CT) are helpful. This article provides an overview of the different procedures for surgical treatment which are a prerequisite for the analysis of postarthroscopic images. In addition typical complications after treatment of meniscal and chondral injuries as well as after ACL reconstruction are described and typical signs in MRI, radiography and CT are explained in detail. (orig.) [German] Kniegelenkverletzungen sind nicht nur bei Profisportlern, sondern auch in der Gesamtbevoelkerung die haeufigsten Gelenkverletzungen. Die Indikation zur arthroskopischen Operation wird gestellt, wenn im Vergleich zur konservativen Therapie ein besseres Ergebnis postarthroskopisch zu erwarten ist und potenzielle Spaetkomplikationen verhindert werden koennten. Die selten aber dennoch auftretenden postarthroskopischen Komplikationen werden zumeist mit der Magnetresonanztomographie (MRT) abgeklaert. Zur weiteren Therapieplanung nach Komplikationen, z. B. wenn eine Kreuzbandrevision notwendig ist, sind die digitale Projektionsradiographie und die Computertomographie (CT) hilfreich. Dieser Artikel bietet eine kurze Uebersicht ueber die unterschiedlichen Operationstechniken, die eine Voraussetzung fuer das Verstaendnis der bildgebenden postoperativen Veraenderungen sind. Weiter wird auf die haeufigsten Komplikationen nach Meniskus- und Knorpeloperationen sowie nach vorderer Kreuzbandrekonstruktion und den damit

  18. Industrie 4.0-Strategien und Reifegrad

    OpenAIRE

    Hofmann, Erik; Oettmeier, Katrin

    2017-01-01

    Industrie 4.0 ist in aller Munde. Ermöglicht wird diese «vierte industrielle Revolution» durch die flexible digitale Vernetzung von Objekten (z.B. Produkten oder Maschinen) über das Internet und andere Netzwerkdienste. Im Rahmen der Fokusstudie «SCM 4.0: Supply Chain Management und digitale Vernetzung» wird der aktuelle Stand der Implementierung von Industrie 4.0 bei Schweizer Unternehmen analysiert. Anhand einer grosszahligen Erhebung wird dabei neben dem derzeitigen Reifegrad auch die vo...

  19. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography

    International Nuclear Information System (INIS)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J.; Stahel, P.F.; Ertel, W.

    2004-01-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  20. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  1. Aorta cross-section calculation and 3D visualization from CT or MRT data using VRML

    Science.gov (United States)

    Grabner, Guenther; Modritsch, Robert; Stiegmaier, Wolfgang; Grasser, Simon; Klinger, Thomas

    2005-04-01

    Quantification of vessel diameters of artherosclerotic or congenital stenosis is very important for the diagnosis of vascular diseases. The aorta extraction and cross-section calculation is a software-based application that offers a three-dimensional, platform-independent, colorized visualization of the extracted aorta with augmented reality information of MRT or CT datasets. This project is based on different types of specialized image processing algorithms, dynamical particle filtering and complex mathematical equations. From this three-dimensional model a calculation of minimal cross sections is performed. In user specified distances, the aorta is cut in differently defined directions which are created through vectors with varying length. The extracted aorta and the derived minimal cross-sections are then rendered with the marching cube algorithm and represented together in a three-dimensional virtual reality with a very high degree of immersion. The aim of this study was to develop an imaging software that delivers cardiologists the possibility of (i) furnishing fast vascular diagnosis, (ii) getting precise diameter information, (iii) being able to process exact, local stenosis detection (iv) having permanent data storing and easy access to former datasets, and (v) reliable documentation of results in form of tables and graphical printouts.

  2. The role of spiral CT in patients with intermediate probability V/Q scans: can spiral CT replace pulmonary angiography?

    International Nuclear Information System (INIS)

    Vu, T.; Glenn, D.; Lovett, I.; Moses, J.; Wadhwa, S.S.; Nour, R.

    2000-01-01

    Full text: Spiral CT (SCT) has been advocated as a replacement for pulmonary angiography (PA)in patients with intermediate probability (IP) ventilation-perfusion lung scans (V/Q). More generally it has been proposed as a replacement for V/Q to detect Pulmonary Embolism. This study investigates the accuracy of SCT in the IP patient group 31 patients with IP scans (Modified PIOPED criteria) who were not at high risk of contrast nephrotoxicity were enrolled to have both SCT and PA within the 24 hours following their V/Q. Patients were classified as IP due to a single segmental mismatch (n=7) or a matched V/Q abnormality corresponding to CXR opacity (n=21), or both (n=3). PA is the gold standard for the detection of PE. SCT was read by an experienced radiologist blinded to the PA results. SCT was performed according to standard protocol. All SCT were technically satisfactory for interpretation. Pulmonary embolism was present in 9/31 patients (29%). Of the patients with PE detected by PA, SCT was positive in 4 (44% sensitivity). Of the 22 patients who did not have PE, SCT was negative in 21 and positive in one (96% specificity). In conclusion SCT has limited sensitivity for the detection of PE in patients with IP lung scans. SCT may not be an adequate replacement for PA. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Evaluation of retrospectively ECG-gated 4-row multidetector CT in patients planned for minimal invasive coronary artery bypass grafting; Die EKG-getriggerte 4-Zeilen-Spiral-CT des Herzens in der praeoperativen Bildgebung vor minimalinvasiver koronarer Bypass-Operation

    Energy Technology Data Exchange (ETDEWEB)

    Begemann, P.G.C.; Ittrich, H.; Koops, A.; Adam, G.; Weber, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Radiologisches Zentrum, Universitaetsklinikum, Hamburg (Germany); Arnold, M.; Detter, C.; Boehm, D.H.; Reichenspurner, H. [Universitaetsklinikum Hamburg-Eppendorf, Herzzentrum, Herz und Gefaesschirurgie, Hamburg (Germany)

    2005-08-01

    Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), coursek of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and

  4. Evaluation of image quality and dose in renal colic: comparison of different spiral-CT protocols

    International Nuclear Information System (INIS)

    Rimondini, A.; Mucelli, R.P.; Dalla Palma, L.; De Denaro, M.; Bregant, P.

    2001-01-01

    The aim of this study was to test different technical spiral-CT parameters to obtain optimal image quality with reduced X-ray dose. Images were acquired with a spiral-CT system Philips Tomoscan AVE1, using 250 mA, 120 kV, and 1-s rotational time. Three protocols were tested: protocol A with 5-mm thickness, pitch 1.6, slice reconstruction every 2.5 mm; protocol B with 3-mm thickness, pitch 1.6, slice reconstruction every 1.5 mm; and protocol C with 3-mm thickness, pitch 2, slice reconstruction every 1.5 mm. Two phantoms were employed to evaluate the image quality. Axial images were acquired, then sagittal and coronal images were reconstructed. Finally, the absorbed X-ray dose for each protocol was measured. Regarding image quality, 5-mm-thick images (protocol A) showed greater spatial resolution and lower noise compared with 3-mm-thick images (protocols B and C) on the axial plane; 3-mm reconstructed sagittal and coronal images (protocols B and C) showed an improved image quality compared with 5-mm reformatted images (protocol A). Concerning X-ray dose, the mean dose was: protocol A 19.6±0.8 mGy; protocol B 14.4±0.6 mGy; protocol C 12.5±1.0 mGy. Our study supports the use of thin slices (3 mm) combined with pitch of 1.6 or 2 in renal colic for X-ray dose reduction to the patient and good image quality. (orig.)

  5. MRT of the locomotor system. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Vahlensieck, Martin; Reiser, Maximilian

    2015-01-01

    The book on MRT of the locomotor system covers the following topics: relevant NMT imaging techniques, spinal cord, shoulder, elbows, wrist and fingers, hip region, knee, lower leg - ankle - foot, temporomandibular joint, skeletal muscles, bone marrow, bone and soft tissue tumors, osteoporosis, sacroiliac joint, jaw and periodontium.

  6. Coxarthrosis; Koxarthrose

    Energy Technology Data Exchange (ETDEWEB)

    Imhof, H.; Czerny, C.; Gahleitner, A.; Grampp, S.; Kainberger, F.; Krestan, C. [Osteologie, Radiodiagnostik, AKH Wien (Austria); Sulzbacher, I. [Institut fuer Klinische Pathologie, AKH Wien (Austria)

    2002-06-01

    ;'activated'' osteoarthritis under standard therapy, unclear joint-pain and before any arthroscopy. (orig.) [German] Koxarthrosen gehoeren zu den am haeufigsten auftretenden Arthrosen. Es besteht eine geringe Praevalenz des maennlichen Geschlechts. Aetiologisch werden primaere and sekundaere Koxarthrosen unterschieden. Primaere (idiopathische) sind aetiologisch unklar, sekundaere beruhen auf bekannten Aetiologien (z. B. Uebergewicht, repetitive Traumen, Fehlstellung bzw. Fehlhaltung, Muskel bzw. Sehnenimbalanz etc.). Pathophysiologisch finden sich bei Arthrosen Knorpel-, Subchondralregion-, Synovialis-, Gelenkfluessigkeitsveraenderungen sowie Abnormitaeten in den periartikulaeren Muskeln. Waehrend im Knorpel stadienhaft oedematoese Schwellung, Defekt mit Riss, Fibrillation, Glatzenbildung und Knorpelregeneratbildung sowie Gelenkspaltverschmaelerung auftreten, zeigen sich subchondral kleinste Oedembildungen, Nekrosen, evtl. Mikrofrakturen und Demineralisation sowie die bekannten subchondralen Sklerosierungen, Zystenbildungen und osteophytaeren Neubildungen. In spaeterer Folge kommt es zu Deformierungen und Fehlstellung. Letztere Veraenderungen sind mittels konventionellen Roentgenaufnahmen, CT und MRT gut abgrenzbar.Von zunehmender Bedeutung ist heute auch die Diagnostik sog. Praearthrosen. Dazu zaehlen aetiologisch u. a. unterschiedliche Fehlstellungen, Fehlformen, evtl. Labrumpathologien sowie die oben genannten Sehnen- und Muskelimbalanzen.Koxarthrosen werden in 3 prognostisch unterschiedliche Typen differenziert, abhaengig von der Migration des Kopfes: die laterokraniale als haeufigste, die mediokaudale und die seltene axiale. Ihre Entstehung duerfte auf unterschiedliche Mechanismen zurueckgehen.Die bildgebende Diagnostik erfolgt beim Vorliegen einer entsprechenden klinischen Symptomatik. Basis der Bildgebung ist heute unveraendert das konventionelle Roentgenbild, gefolgt von CT und MRT. Zur Diagnostik der ''aktivierten Arthrose'' wird nach wie vor die

  7. Spiral CT: An innovative method of volumetric recording. Pt. 1

    International Nuclear Information System (INIS)

    Kalender, W.A.; Vock, P.; Polacin, A.; Soucek, M.

    1990-01-01

    A major advance in the field of CT diagnosis has been made with the development of spiral computed tomography. It permits a complete photographic recording of volumes in such a way that even 'minor' pathological changes can be detected and reconstructed providing the absence of respiration-induced organ displacement. During one session, in which up to 24 360deg scans may be obtained within 24 seconds, the patient is continuously shifted at a speed of 10 mm/s, which permits the volumes recorded to be increased up to a height of 24 cm. The underlying methodology is described, as is the procedure to be used in the reconstruction of planar pictures from the volumes recorded. (orig./GDG) [de

  8. Automated detection and volumetric segmentation of the spleen in CT scans; Automatische Detektion und volumetrische Segmentierung der Milz in CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Hammon, M.; Dankerl, P.; Janka, R.; Uder, M.; Cavallaro, A. [Universitaetsklinikum Erlangen (Germany). Radiologisches Inst.; Kramer, M.; Seifert, S.; Tsymbal, A.; Costa, M.J. [Siemens AG, Erlangen (Germany). Corporate Technology

    2012-08-15

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like ''marginal space learning'' and ''boosting algorithms''. 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm{sup 3} + 0.58 (width x length x thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 ({+-} 2.4) seconds. The average splenic volume measured by aV was 268.21 {+-} 114.67 cm{sup 3} compared to 281.58 {+-} 130.21 cm{sup 3} in mV and 268.93 {+-} 104.60 cm{sup 3} in eV. The correlation coefficient was 0.99 (coefficient of determination (R{sup 2}) = 0.98) for aV and mV, 0.91 (R{sup 2} = 0.83) for mV and eV and 0.91 (R{sup 2} = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R{sup 2} = 0.84), mV and eV (0.95; R{sup 2} = 0.91) and aV and eV (0.83; R{sup 2} = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. (orig.)

  9. Benign chordoma of the sacral bone. Radiologic appearance and differential dignosis; Benignes Chordom des Os Sacrum. Radiologische Morphologie und differential-diagnostische Aspekte

    Energy Technology Data Exchange (ETDEWEB)

    Pegios, W. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Vogl, T.J. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Rausch, M. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Klein, U. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Balzer, J.O. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Hammerstingl, R. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Mack, M.G. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Freie Univ. Berlin (Germany)

    1994-12-31

    Chordomas constitute 3-4% of all primary bony tumors [17, 20] and they arise from remnants of the notochord [4]. They can occur anywhere along the skull base and spine, where the notochord extends. 50% arise in the sacrum, 35% in the clivus and 15% in the vertebrae [17, 20]. Chordomas usually occur after the second decade with the highest incidence between the fifth and seventh decade. There is a male predominance, with roughly a 2 to 1 male-to-female ratio. Children are rarely affected [5, 25, 34]. In this article a case of a patient with a Chordoma of the sacrum is presented. After a fall on the coccyx the patient complained of recurrent and altogether increasing pain for some years. The clinical diagnosis was fracture of the coccyx with consecutive formation of callus. Finally the MRI showed a characteristically increased signal intensity in the T2-weighted spin-echo sequence (SE). With the help of MRI guided biopsy the diagnosis of a benign highly differentiated chordoma could be confirmed. (orig.) [Deutsch] Chordome stellen 3 bis 4% aller primaeren Knochentumoren dar [17, 20] und gehen von den Resten der primitiven Chorda dorsalis aus [4]. Sie koennen ueberall dort auftreten, wo embryonale Reste des Chordagewebes vorhanden sind: 50% im Sacrum, 35% im Clivus und mit 15% an den Wirbelkoepern [17, 20]. Chordome werden in der Regel nach der zweiten Lebensdekade beobachtet und erreichen ihre hoechste Inzidenz zwischen der fuenften und der siebten Lebensdekade. Sie zeigen eine Praeferenz fuer das maennliche Geschlecht mit eine Relation von ungefaehr 2:1. Kinder sind seltener betroffen [5, 25, 34]. Im folgenden soll ein Patient mit einem Chordom des Os Sacrum vorgestellt werden. Nach Sturz auf das Steissbein klagte der Patient jahrelang ueber rezidivierende und insgesamt zunehmende Schmerzsymptomatik. Die klinische Diagnose lautete Zustand nach Steissbeinfraktur mit Kallusbildung. Die schliesslich durchgefuehrte MRT zeigte eine charakteristische erhoehte

  10. NMR imaging of the vertebral column and the spinal canal. 2. rev. and enl. ed.; MRT der Wirbelsaeule und des Spinalkanals

    Energy Technology Data Exchange (ETDEWEB)

    Forsting, Michael [Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie; Uhlenbrock, Detlev [St.-Josefs-Hospital, Dortmund (Germany). MVZ Radiologie, Nuklearmedizin und Strahlentherapie; Wanke, Isabel [Privatklinikengruppe Hirslanden, Zurich (Switzerland); Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie

    2009-07-01

    The book on the MRT (magnetic resonance tomography) of the vertebral cord and spinal canal covers the following topics: physics fundamentals and application; malformation of the spinal canal; degenerative vertebral column diseases; vertebral column and spinal canal carcinomas; inflammatory diseases of the vertebral column and the spinal canal; applicability of MRT in case of acute spinal cord traumata; vascular diseases of the spinal canal.

  11. Accuracy and reliability of thyroid volumetry using spiral CT and thyroid volume in a healthy, non-iodine-deficient Chinese adult population

    Energy Technology Data Exchange (ETDEWEB)

    Shu Jian, E-mail: shujiannc@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Zhao Jiannong, E-mail: zhaojiannong@tom.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Guo Dajing, E-mail: guodaj@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Luo Yindeng, E-mail: yindengluo_1019@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Zhong Weijia, E-mail: zhongweijia2003@eyou.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China); Xie Weibo, E-mail: radiologycq@163.com [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, 74 Linjiang Road, Yuzhong District, Chongqing 400010 (China)

    2011-02-15

    Objective: The purpose of this study was to assess the accuracy and reliability of thyroid volumetry using spiral CT and to investigate thyroid volumes for a healthy, non-iodine-deficient adult population in southwestern region of China. Materials and methods: Spiral CT was performed in phantoms and adult subjects with normal thyroid, and the volumes were measured by observers with 5 years or more of CT experience. The phantom volumes and the thyroid volumes of all subjects were noted. Results: For the thyroid phantoms, there was no significant difference between the true and CT calculated volumes (t = 0.862, P = 0.399), and the correlation was excellent (ICC = 0.9995, P = 0.000). In the subjects for reliability analysis, the intraobserver or interobserver differences for CT volumetric measurement of thyroid were not significant (P > 0.05). The intraobserver or interobserver correlations were very high (ICC > 0.99, P < 0.001). In the subjects for population analysis, the median of the thyroid volumes was 11.45 cm{sup 3}. The nonparametric Mann-Whitney U-test showed no significant difference for the thyroid volume between sexes (U = 4388.00, Z = -1.118, P = 0.264). The nonparametric Kruskall-Wallis test showed no significant difference in all age groups ({chi}{sup 2} = 13.466, P = 0.062). There was a slight negative correlation between the thyroid volume and age (r{sub s} = -0.166, P = 0.019). Conclusion: The accuracy and reliability of multi-slice spiral CT in measuring thyroid volume are very high. The thyroid volumes are not significantly difference between genders or among decades for the healthy, non-iodine-deficient adult population in southwestern region of China.

  12. Intramural hemorrhage of the thoracic aorta - imaging features and differential diagnosis; Das intramurale Haematom der thorakalen Aorta: Bildgebende Diagnostik und Differentialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T. [Bonn Univ. (Germany) Radiologische Klinik; Abu-Ramadan, D. [Bonn Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Busch, M. [Bonn Univ. (Germany) Radiologische Klinik; Bierhoff, E. [Bonn Univ. (Germany). Pathologische Inst.; Kreft, B. [Bonn Univ. (Germany) Radiologische Klinik; Kuhl, C. [Bonn Univ. (Germany) Radiologische Klinik; Lutterbey, G. [Bonn Univ. (Germany) Radiologische Klinik; Keller, E. [Bonn Univ. (Germany) Radiologische Klinik; Schild, H. [Bonn Univ. (Germany) Radiologische Klinik

    1996-09-01

    Purpose: Aortic wall thickening due to intramural hemorrhage may be the only sign of aortic dissection. The aim of this study was to evaluate the incidence, imaging features and differential diagnoses of intramural hemorrhage (IMH) of the thoracic aorta. Methods: 98 patients with clinically suspected aortic dissection were investigated via Spiral-CT and MRT. Diagnosis of IMH based on the presence of smooth crescentic or concentric wall thickening over a longer segment of the thoracic aorta without flow visualization and without compression or distortion of the aortic lumen. Results: 69 patients had classic aortic dissections and 7 patients were diagnosed to have IMH of the thoracic aorta. One patient with IMH of the ascending aorta died of aortic rupture and subsequent pericardial tamponade 12 hours after onset of symptoms. In one patient with IMH of the descending aorta on initial examination, there was a progression of overt aortic dissection at follow-up after three weeks. In two patients with IMH of the descending aorta, wall thickening decreased in size at follow-up (10-15 weeks), whereas in one patient it remained unchanged. Conclusion: IMH of the aorta should be considered a precursor of aortic dissection. At follow-up IMH may decrease in size, rupture or progress to overt aortic dissection. (orig.) [Deutsch] Ziel: Eine aortale Wandverdichtung als Ausdruck eines intramuralen Haematoms kann die einzige Manifestation einer Aortendissektion sein. Ziel dieser Arbeit war die Evaluierung der Inzidenz, bildgebenden Aspekte und Differentialdiagnosen dieses in der deutschsprachigen Literatur wenig bekannten Krankheitsbildes. Methode: 98 Patienten mit klinischem Verdacht auf eine Aortendissektion wurden MR- und computertomographisch untersucht. Kriterium fuer das Vorliegen eines intramuralen Haematoms war der Nachweis einer laengerstreckigen aortalen Wandverdickung ohne Flussnachweis sowie ohne Konfigurationsaenderung des aortalen Lumens. Ergebnisse: 69 Patienten

  13. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  14. Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode

    International Nuclear Information System (INIS)

    Wolf, Florian; Loewe, Christian; Plank, Christina; Schernthaner, Ruediger; Bercaczy, Dominik; Lammer, Johannes; Leschka, Sebastian; Goetti, Robert; Marincek, Borut; Alkadhi, Hatem; Homolka, Peter; Friedrich, Guy; Feuchtner, Gudrun

    2010-01-01

    To evaluate coronary stents in vitro using 128-slice-dual-source computed tomography (CT). Twelve different coronary stents placed in a non-moving cardiac/chest phantom were examined by 128-slice dual-source CT using three CT protocols [high-pitch spiral (HPS), sequential (SEQ) and conventional spiral (SPIR)]. Artificial in-stent lumen narrowing (ALN), visible inner stent area (VIA), artificial in-stent lumen attenuation (ALA) in percent, image noise inside/outside the stent and CTDIvol were measured. Mean ALN was 46% for HPS, 44% for SEQ and 47% for SPIR without significant difference. Mean VIA was similar with 31% for HPS, 30% for SEQ and 33% for SPIR. Mean ALA was, at 5% for HPS, significantly lower compared with -11% for SPIR (p = 0.024), but not different from SEQ with -1%. Mean image noise was significantly higher for HPS compared with SEQ and SPIR inside and outside the stent (p < 0.001). CTDIvol was lower for HPS (5.17 mGy), compared with SEQ (9.02 mGy) and SPIR (55.97 mGy), respectively. The HPS mode of 128-slice dual-source CT yields fewer artefacts inside the stent lumen compared with SPIR and SEQ, but image noise is higher. ALN is still too high for routine stent evaluation in clinical practice. Radiation dose of the HPS mode is markedly (less than about tenfold) reduced. (orig.)

  15. 3 tesla magnetic resonance imaging in children and adults with congenital heart disease; 3-Tesla-Magnetresonanztomographie zur Untersuchung von Kindern und Erwachsenen mit angeborenen Herzfehlern

    Energy Technology Data Exchange (ETDEWEB)

    Voges, I.; Hart, C.; Kramer, H.H.; Rickers, C. [Universitaetsklinikum Schleswig-Holstein, Klinik fuer angeborene Herzfehler und Kinderkardiologie, Kiel (Germany); Jerosch-Herold, M. [Harvard Medical School, Department of Radiology, Brigham and Women' s Hospital, Boston (United States); Helle, M. [Universitaetsklinikum Schleswig-Holstein, Institut fuer Neuroradiologie, Kiel (Germany)

    2010-09-15

    Cardiovascular magnetic resonance imaging (CMR) has become a routinely used imaging modality for congenital heart disease. A CMR examination allows the assessment of thoracic anatomy, global and regional cardiac function, blood flow in the great vessels and myocardial viability and perfusion. In the clinical routine cardiovascular MRI is mostly performed at field strengths of 1.5 Tesla (T). Recently, magnetic resonance systems operating at a field strengths of 3 T became clinically available and can also be used for cardiovascular MRI. The main advantage of CMR at 3 T is the gain in the signal-to-noise ratio resulting in improved image quality and/or allowing higher acquisition speed. Several further differences compared to MRI systems with lower field strengths have to be considered for practical applications. This article describes the impact of CMR at 3 T in patients with congenital heart disease by meanings of methodical considerations and case studies. (orig.) [German] Die kardiovaskulaere Magnetresonanztomographie (MRT) hat sich zu einer etablierten bildgebenden Methode zur Untersuchung von Patienten mit angeborenen Herzfehlern entwickelt. Sie erlaubt in einer einzigen Untersuchung die exakte Beurteilung von Anatomie, globaler und regionaler Funktion, Blutfluessen sowie der myokardialen Perfusion und Vitalitaet. In der klinischen Routine erfolgen die Untersuchungen zumeist bei einer Feldstaerke von 1,5 Tesla (T), mittlerweile gibt es jedoch Geraete und Bildgebungstechniken, die die kardiovaskulaere MRT auch bei 3 T ermoeglichen. Der wesentliche Vorteil der MRT bei 3 T ist das hoehere Signal-zu-Rausch-Verhaeltnis, das sowohl zu einer Verbesserung der Bildqualitaet als auch zu einer Verkuerzung der Untersuchungszeit genutzt werden kann. Darueber hinaus bestehen verschiedene andere Unterschiede gegenueber Systemen mit niedriger Feldstaerke, die im praktischen Einsatz beachtet werden muessen. Dieser Artikel beschreibt die Erfahrungen der 3-T-MRT fuer die

  16. Radiological diagnostics in CUP syndrome; Radiologische Diagnostik des CUP-Syndroms

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, P.M.; Nikolaou, K.; Graser, A.; Reiser, M.F.; Cyran, C.C. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Rominger, A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2014-02-15

    , diffusion), e.g. investigation of breast carcinoma or prostate carcinoma. Whole body staging stands at the beginning of the diagnostic algorithm in CUP syndrome to localize a potential primary tumor. Clinically, contrast-enhanced CT of the neck, thorax and abdomen is frequently applied; however, many studies have demonstrated augmented sensitivity of {sup 18}F-FDG PET-CT for the detection of primary tumors and metastatic tumor manifestations. (orig.) [German] Im therapeutischen Management des Cancer-of-unknown-primary(CUP)-Syndroms spielt die bildgebende Diagnostik eine zentrale Rolle zur Lokalisation des Primaertumors, zur Identifikation von Tumoren, fuer die ein dediziertes Behandlungsschema zur Verfuegung steht, sowie zur Charakterisierung klinisch-pathologischer Subentitaeten, die das weitere diagnostische und therapeutische Procedere bestimmen und eine Einschaetzung der Prognose erlauben. Zur Verfuegung stehende radiologische Modalitaeten umfassen die Projektionsradiographie, die Computertomographie (CT), die Magnetresonanztomographie (MRT) und die Sonographie sowie die Hybridverfahren Positronenemissionstomographie(PET)-CT und MR-PET. In der Ganzkoerperbildgebung hat die CT eine hohe Sensitivitaet fuer Tumoren, die haeufig als metastasierte Tumorerkrankung auftreten. Nach aktueller Literatur ist die CT bei Patienten mit Pankreaskarzinom in 86% der Faelle diagnostisch, bei Patienten mit Kolonkarzinom in 36% und bei Patienten mit Bronchialkarzinom in 74%. Des Weiteren zeigte eine Metaanalyse, dass bei Patienten mit Plattenepithelkarzinom und zervikalen Lymphknotenmetastasen die CT in 22% der Faelle den Primaertumor lokalisieren konnte, im Vergleich zu 36% Detektionsrate der MRT und 28-57% der PET-CT mit {sup 18}F-FDG (Fluordesoxyglukose). Der MRT kommt auf Grund des hohen Weichteilkontrasts und der Moeglichkeit zur funktionellen Bildgebung besondere Bedeutung bei der Lokalisation primaer okkulter Tumoren bei Organuntersuchungen zu, z. B. beim Mamma- oder dem

  17. Osteogenic tumors of bone; Osteogene Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Jobke, B. [Deutsches Krebsforschungszentrum (DKFZ), Abtl. Radiologie, Heidelberg (Germany); Werner, M. [MVZ des HELIOS Klinikum Emil von Behring, Orthopaedische Pathologie - Referenzzentrum, Institut fuer Gewebediagnostik Berlin, Berlin (Germany)

    2016-06-15

    Informationen wie Patientenalter, Anamnese und Vorzugslokalisation die Diagnose und Differenzialdiagnose zu stellen. Bei der Recherche werden zum einen grosse publizierte Falldaten selektiv wiedergegeben, zum anderen eigene und extern publizierte und anerkannte Tumorkriterien verglichen. Zu Beginn der Primaerdiagnostik einer ossaeren Laesion steht die Detektion, die durch die Sensitivitaet der gewaehlten Methode bestimmt wird. Bei osteogenen Laesionen stehen am Anfang das konventionelle Roentgen in 2 Ebenen und die Computertomographie (CT). Zur Diagnosefindung und lokalen Ausbreitungsdiagnostik bzw. Biopsieplanung muessen z.T. noch eine lokale Magnetresonanztomographie (MRT) oder Szintigraphie angeschlossen werden. Die MRT als Stand-alone-Diagnostik ist unzureichend. Bei malignen Tumoren erfolgt ein Staging mit einer variablen Kombination aus CT-Thorax, MRT, Szintigraphie und Positronenemissionstomographie. Das Osteosarkom stellt neben dem Ewing- und Chondrosarkom den groessten Anteil der malignen Knochentumoren, alle Subentitaeten sind deutlich seltener. Unter den benignen osteogenen Knochentumoren hat das Osteoidosteom die groesste Inzidenz, mit typischen Schmerzen, Lokalisation und Alterspraedilektion. Diagnostik und Therapie von malignen Knochentumoren sollten wegen der erheblichen therapeutischen Konsequenzen fuer die Patienten bevorzugt in spezialisierten Zentren erfolgen. Bei unklaren Faellen sollten immer Zweitmeinungen eingeholt werden. (orig.)

  18. CT appearance of menetrier's disease (a report of 4 cases)

    International Nuclear Information System (INIS)

    Peng Weijun; Zhang Pei; Zhou Kangrong; Chen Huiming

    2000-01-01

    Objective: To define the CT imaging characteristic of menetrier's disease. Methods: Four patients with proved Menetrier's disease were retrospectively studied by means of CT performed with the water as oral contrast, hypotonic agent and dynamic or spiral CT technique. Results: All cases showed that the enlarged rugae were seen projecting into the gastric lumen, but the gastric wall was otherwise normal. CT detected all lesions and made a confirmed diagnosis before pathology biopsy. Conclusion: The primary result revealed that the CT appearance of Menetrier's disease was quite characteristic, CT is a very valuable tool for the diagnosis of Menetrier's disease

  19. Evaluation of hepatic alveolar echinococcosis with multi-slices spiral CT

    International Nuclear Information System (INIS)

    Liu Wenya; Lou Jianru; Xing Yan; Wang Jing; Wang Haitao

    2005-01-01

    Objective: To analyze the multi-slices spiral CT (MSCT) findings of hepatic alveolar echinococcosis (HAE), and to evaluate the value of MSCT for diagnosis of HAE. Methods: Twenty-six cases with HAE were scanning by MSCT. The raw data were transmitted to advanced workstation for reconstruction imaging. Correlated studies were made between the CT features and pathology or other imaging results. Results: Altogether 28 lesions were detected. They all revealed as heterogeneous hypodense mass with ill-defined boundary in plain CT but were easily being distinguished from surrounding parenchyma after contrast medium injection. Characteristics of the lesions include different amount of calcification (26/26), liquefied necrosis in center area (20/26), peripheral lacunae or alveolar signs (15/26 ), compensatory hypertrophy of healthy hepatic part (18/26) and the retraction in the involved hepatic lobe or segment (12/26). The lesions that located at or extended to hepatic hilum caused dilatation of intra-hepatic biliary ducts (9/26), splenomegaly (12/26 ), and ascites (1/26). MSCT angiography (CTA) depicted signs of abnormalities of hepatic vessels such as compression, displacement, encasement and occlusion. Compared with findings of operation, the sensitivity, specificity and positive prediction value of CTA for evaluating the hepatic artery system disorders were 88%, 96% and 93%, respectively; and for portal venous system were 95%, 100% and 95%, respectively; while for hepatic venous system were 96%, 86% and 96%, respectively. Conclusion: MSCT is able to comprehensive display the CT features and vessels complication of HAE. It provides reliable imaging for both accuracy diagnosis and proper treatment of the disease. (authors)

  20. Septic-embolic and septic-metabolic brain abscess; Septisch-embolischer und septisch-metastatischer Hirnabszess

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.; Henkes, H.; Kuehne, D. [Alfried-Krupp-Krankenhaus Essen (Germany). Klinik fuer Radiologie und Neuroradiologie; Felber, S. [Universitaetsklinik Innsbruck (Austria). Klinische Abt. der Radiologie I; Jaenisch, W. [Freie Univ. Berlin (Germany). Inst. fuer Neuropathologie; Woitalla, D. [Bochum Univ. (Germany). St. Josef-Hospital

    2000-11-01

    The hematogeneous spread of bacteria, fungi and protozoa may also reach the brain vessels, which happens mostly through septic emboli. >From such an embolus a metastatic focal encephalitis and later a septic-embolic brain abscess may arise. The most frequently underlying infections that may cause septic emboli are bacterial endocarditis as well as bacterial infections of artificial heart valve prostheses. Congenital heart malformations with a right-to-left shunt also play here a certain role. Basically, however, all septic conditions and bacteriemias may cause septic-embolic brain abscesses. They occur frequently as multiple lesions. MRI is superior to CT in depicting the different stages of evolution from focal encephalitis, through the hardly encapsulated early abscess, to the formation of a membrane and later a dense fibrous capsule. The medical treatment of a brain abscess requires properly performed CT or MRI follow-up examinations in order to realize early enough a possible growing of such a lesion. (orig.) [German] Die haemoatogene Ausbreitung von Bakterien, Pilzen oder Protozoen bis in die Hirngefaesse erfolgt meist durch eine septische Embolie. Es entstehen eine metastatische Herdenzephalitis und im weiteren Verlauf daraus ein septisch-embolischer Hirnabszess. Die haeufigste Grunderkrankung die zu septischen Embolien fuehrt, ist die bakterielle Endokarditis sowie die bakterielle Infektion von Herzklappenprothesen. Eine besondere Bedeutung kommt hier den angeborenen kardialen Fehlbildungen mit Rechts-Links-Shunt zu. Grundsaetzlich koennen jedoch alle Bakteriaemien zu septisch-embolischen Hirnabszessen fuehren. Septisch-embolische Hirnabszesse treten aufgrund ihres Entstehungsmechanismus haeufig multipel auf. Die CT und besser noch die MRT erlauben die Darstellung aller Entwicklungsstadien von der Herdenzephalitis ueber den kaum abgegrenzten Abszess, die Membranbildung bis zur Entstehung einer dicken, die eitergefuellte Hoehle allseits umgebenden

  1. Induced pneumoperitoneum in spiral CT evaluation of gastric cancer

    International Nuclear Information System (INIS)

    Guo Hua; Gao Jianbo; Li Yintai; Yang Xuehua; Chen Xuejun; Guan Sheng

    2001-01-01

    Objective: To evaluate the diagnostic value and clinical significance of preoperative staging in gastric cancer with induced pneumoperitoneum in spiral CT (SCTPP). Methods: Both routine SCT and SCTPP were performed in 52 lean patients suffered from gastric cancers, and comparison was made between SCT findings and surgical and histopathologic findings. Results: The accuracy of routine SCT and SCTPP in determining the T-staging was 72% and 96%, respectively (x 2 = 8.0, P 2 = 0.006, P > 0.05). The sensitivity in determining M-staging was 61% and 100%, respectively (x 2 = 0.04, P 2 6.03, P < 0.05). Conclusion: The accuracy of SCTPP in determining preoperative staging of gastric cancer was significantly higher than that of routine SCT. SCTPP has important guiding significance for the selection of the treatment strategy in gastric cancer

  2. Functional MRI procedures in the diagnosis of brain tumors. Perfusion- and diffusion-weighted imaging; Funktionelle MR-Verfahren in der Diagnostik intraaxialer Hirntumoren. Perfusions- und Diffusions-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M. [Universitaetsklinikum Heidelberg (Germany). Neurologische Klinik, Abteilung Neuroradiologie; Heiland, S.; Sartor, K.

    2002-08-01

    Despite the increased diagnostic accuracy of contrast material enhanced MR imaging, specification and grading of brain tumors are still only approximate at best: neither morphology, nor relaxation times or contrast material enhancement reliably predict tumor histology or tumor grade. As histology and tumor grade strongly influence which therapy concept is chosen, a more precise diagnosis is mandatory. With diffusion- and perfusion-weighted MR imaging (DWI, PWI) it is now possible to obtain important information regarding the cellular matrix and the relative regional cerebral blood volume (rrCBV) of brain tumors, which cannot be obtained with standard MR techniques. These dynamic-functional imaging techniques are very useful in the preoperative diagnosis of gliomas, lymphomas, and metastases, as well as in the differentiation of these neoplastic lesions from abscesses, atypical ischemic infarctions, and tumor-like manifestations of demyelinating disease. Additionally, they appear suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy and therapy. After therapy these techniques are helpful to better assess the tumor response to therapy, possible therapy failure and therapy complications such as radiation necrosis. (orig.) [German] Die radiologische Diagnostik intraaxialer Hirntumoren ist durch die Magnetresonanztomographie (MRT) erheblich verbessert worden, besonders nach Einfuehrung der paramagnetischen Kontrastmittel. Mit konventionellen MR-Verfahren ist aber noch keine verlaessliche Unterscheidung zwischen Gliomen, Metastasen, primaeren Lymphomen und tumorsimulierenden entzuendlichen Erkrankungen moeglich. In dieser Hinsicht vielversprechend sind neue, funktionell-dynamische MR-Verfahren, mit denen sich nicht-invasiv die zerebrale Wasserdiffusion und Mikrozirkulation erfassen lassen und die eine bessere Gewebecharakterisierung erlauben als die herkoemmlichen MR-Methoden. Die Perfusions-MRT erfasst

  3. Superconducting MRI system, MRT-50A

    International Nuclear Information System (INIS)

    Sugimoto, Hiroshi; Asahina, Kiyotaka

    1987-01-01

    The writers' developmental work on MRI (magnetic resonance imaging) was started in 1983. The model used first was MRT-15A (0.15 T). The next model was MRT-22A (0.22 T) which had a magnetic self-shield. As for the development of superconducting MRI system, they started clinical evaluation at Toshiba Central Hospital MRI Center in 1984 and got the official approval in 1985. For the model, use was made of MRT-50A (0.5 T) employing a superconducting magnet made by Toshiba. Herein represented are the basis of the images obtained through MRT-50 and the fact that the application fields of MRI are going on increasing (not only to brain and spine areas but also to the areas of the chest, abdomen and joints), and also the results of the work-in-progress of application software. (author)

  4. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT

    NARCIS (Netherlands)

    M. Oudkerk (Matthijs); C.G. Torres; B. Song; M. Konig; J. Grimm; J. Fernandez-Cuadrado; B. op de Beeck; M. Marquardt; P. van Dijk (Pieter); J.C. de Groot (Jan Cees)

    2002-01-01

    textabstractPURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were

  5. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  6. Extrathoracic manifestations of tuberculosis; Extrathorakale Manifestationen der Tuberkulose

    Energy Technology Data Exchange (ETDEWEB)

    Kienzl-Palma, D.; Prosch, H. [Medizinische Universitaet Wien, Abteilung fuer Allgemeine Radiologie und Kinderradiologie, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2016-10-15

    des ZNS oder des muskuloskeletalen Systems kommen. Die radiologische Methode zur Abklaerung einer extrathorakalen Tbc-Manifestation ist in den meisten Faellen initial die CT. Beim zerebralen oder muskuloskeletalen Befall hingegen stellt die MRT mit Kontrastmittelgabe den Goldstandard dar. Radiologisch ist die extrathorakale Manifestation haeufig nicht von entzuendlichen Veraenderungen anderer Genese oder von malignen Prozessen zu unterscheiden. Auch aufgrund der meist unspezifischen Symptomatik erfolgt die Diagnose oftmals spaet. In diesem Artikel werden die verschiedenen radiologischen Manifestationen der extrathorakalen Tbc zusammengefasst und diskutiert. Radiologische Modalitaeten zur Abklaerung einer extrathorakalen Tbc sind CT und MRT. Das konventionelle Roentgen und die Durchleuchtung spielen bei Verdacht auf extrathorakale Tbc im klinischen Alltag keine Rolle mehr. Die extrathorakale Manifestation der Tbc ist oftmals radiologisch nicht von anderen Infektionen und Malignomen zu unterscheiden. Daher sollte an die Moeglichkeit einer extrathorakalen Tbc besonders bei immunsupprimierten Menschen wie Obdachlosen, Alkohol- oder drogenabhaengigen Personen und solchen mit Migrationshintergrund aus den Endemiegebieten der Tbc gedacht werden. Radiologische Modalitaeten zur Abklaerung einer extrathorakalen Tbc-Diagnostik sind die CT v. a. fuer den abdominellen Befall und bei Lymphadenopathie sowie die MRT mit Kontrastmittelgabe bei Verdacht auf Manifestation im muskuloskeletalen System und ZNS. (orig.)

  7. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  8. Diagnosis of tumors in the shoulder girdle by means of MRI; Diagnostik von Tumoren des Schulterguertelbereichs in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Schlecht, I.; Gaffke, G.; Stroszczynski, C.; Felix, R. [Charite Campus Virchow-Klinikum, Berlin (Germany). Strahlenklinik und Poliklinik

    2001-07-01

    The aim of the study was to estimate the value of MRI for evaluation of tumors of the shoulder girdle. We diagnosed respectively 13 patients with lesions in the shoulder region. The imaging has been done with a 'Magnetom SP 63' (Siemens, Erlangen, Germany). The protocol consisted of T1- and T2-based SE-sequences in axial slice orientation, T1-based imaging in coronary respectively in sagittal slice orientation as well as T1-based sequences after application of contrast medium. The evaluation of the tumor expansion within the soft tissue was possible. The exact diagnosis in some individual cases - neurinoma, cyst of the synovia - could be found by MRI. Estimation of the dignity in the case of infiltrative growth was possible in most cases. To assess the exact type of tumor was often difficult. Especially the dignity of the cartilaginous tumors could not be precisely described. (orig.) [German] Ziel der Arbeit war es, den Stellenwert der MRT zur Beurteilung von Raumforderungen im Schulterguertelbereich zu evaluieren. Wir konnten retrospektiv 13 Patienten mit Laesionen in der Schulterregion evaluieren. Die Untersuchungen erfolgten an einem 1,5 T supraleitenden Magneten ('Magnetom SP 63', Firma Siemens, Erlangen Deutschland). Das Untersuchungsprotokoll umfasste T1- und T2-gewichtete SE-Sequenzen in axialer Schnittfuehrung und T1-gewichtete Aufnahmen in schraeg koronarer bzw. schraeg sagittaler Schnittfuehrung sowie T1-gewichtete Sequenzen nach Kontrastmittelgabe. Die Beurteilung der Tumorausdehnung in die Weichteile ist mittels der MRT moeglich. Eine Diagnose ist in Einzelfaellen - Neurinom und Synovialzyste - erst mit der Kernspintomographie sicher zu stellen. Ein infiltratives Wachstum laesst sich in der Regel nachweisen, eine Artdiagnose ist jedoch haeufig nicht moeglich. Die Dignitaet konnte insbesondere bei cartilaginaeren Tumoren nicht eindeutig festgelegt werden. (orig.)

  9. Tumors of the sellar region; Tumoren der Sellaregion

    Energy Technology Data Exchange (ETDEWEB)

    Lieb, J.M. [Imamed Radiologie Nordwest, Basel (Switzerland); Ahlhelm, F.J. [Kantonsspital Baden, Abteilung fuer Neuroradiologie, Baden (Switzerland)

    2017-09-15

    , which can be small and often secretory or larger and often non-secretory. (orig.) [German] Die Anatomie der Sellaregion ist komplex und tumoroese Gebilde der Sellaregion sind sehr variabel, da sie von den verschiedensten Geweben der Sellaregion ausgehen koennen, von gutartig bis lebensbedrohlich. Dennoch - bei knapp 80 % der Tumoren der Sellaregion handelt es sich um eine Laesion der 5 haeufigsten, naemlich Adenom, Meningeom, Aneurysma, Astrozytom und Kraniopharyngeom. Neben den klinischen und laborchemischen Befunden sind die MRT- und CT-Befunde einschliesslich der genauen anatomische Lage und des Ausbreitungsmusters der Laesion entscheidend fuer die Diagnose. Goldstandard fuer die bildgebende Diagnostik ist die multiplanare, duennschichtige, kontrastverstaerkte MRT mit hohem Weichteilkontrast. CT und Gefaessdarstellungen sind komplementaere Verfahren in ausgewaehlten Faellen und oft auch zur praeoperativen Planung. Waehrend die meisten Tumoren der Sellaregion mit multiplanarer kontrastverstaerkter MRT gut darstellbar sind, koennen fuer sehr kleine intrahypophysaere Mikroadenome dynamische, kontrastmittelverstaerkte T1w-Sequenzen notwendig sein. Haeufig sind Mikroadenome nur aufgrund des differenten Perfusionsmusters vom uebrigen Hypophysengewebe eindeutig abzugrenzen. Auch koennen weiterentwickelte diffusionsgewichtete Sequenzen fuer die Artdiagnose nuetzlich sein. Tumoren der Sellaregion koennen bildgebend unterteilt werden in intra- und extrahypophysaere Laesionen sowie intrinsische Schaedelbasistumoren. Die haeufigsten Laesionen sind die Adenome, diese werden in hormonaktiv und -inaktiv als auch in Mikro- und Makroadenome unterteilt. Bei klinischem oder laborchemischem Verdacht auf eine Laesion der Sellaregion sollte als primaeres bildgebendes Verfahren die kontrastverstaerkte, duennschichtige MRT angestrebt werden. Der Schluessel zur Diagnose liegt stets in der praezisen anatomischen Lokalisation der Laesion und im Ausbreitungsmuster. Die haeufigste Pathologie der

  10. Prevalence of emphysematous changes as shown by low-dose spiral CT screening images in 6144 healthy subjects

    International Nuclear Information System (INIS)

    Nawa, Takeshi

    2002-01-01

    We assessed the prevalence of emphysematous changes among healthy workers and retired persons, using subjective evaluations of low-dose spiral CT images obtained during thoracic CT screenings for lung cancer. Among 6144 male participants (50-69 years old; mean age, 57), we detected 686 cases (11.2%) with emphysematous changes. The majority (95.3%) of CT-detected emphysema cases were in current or former smokers, and 169 cases (24.6%) showed significant obstructive impairment. Of 236 cases with emphysematous changes in the internal region (more than 20 mm from the costal margin), 98 (41.5%) had significant obstructive impairment. Smoking was found to be the major risk factor for CT-detected emphysema. Longitudinal observation of the emphysema cases, as well as health care support for cessation of smoking, is very important. (author)

  11. CT-guided percutaneous neurolysis methods. State of the art and first results; CT-gesteuerte Neurolysen. Stand der Technik und aktuelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Richter, G.M. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Roeren, T. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-09-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [Deutsch] Thorakale und lumbale Sympathikolyse sowie die Zoeliakusblockade

  12. MRI of the fingers in patients with systemic scleroderma. Early results of contrast-enhanced examinations on a dedicated MRI system; MRT der Finger bei systemischer Sklerodermie. Erste Ergebnisse mit kontrastverstaerkten Untersuchungen an einem dedizierten MRT-System

    Energy Technology Data Exchange (ETDEWEB)

    Bonel, H.; Seemann, M.; Reiser, M. [Inst. fuer Radiologische Diagnostik, Klinikum Grosshadern, Univ. Muenchen (Germany); Messer, G.; Walchner, M.; Roecken, M. [Dermatologische Klinik und Poliklinik, Univ. Muenchen (Germany)

    1997-10-01

    Purpose. To estimate disease activity in patients with systemic sclerosis using contrast-enhanced MRI of the skin. Material and Methods. In a pre-study, sequences of a low-field (0.2 T) scanner (Artoscan, Esaote, Genova, Italy) were optimized for detection of intravenous contrast (0.1 mmol/l Gd-DTPA) in six patients with the autoimmune disease systemic scleroderma. Based on the results of the pre-study, 17 patients with scleroderma (7 sclerotic/10 active inflammatory disease) were scanned using gradient-spoiled 3D GRE sequences (FA 90 , TR 100 ms, TE 18 ms), which had been established as most sensitive for intravenous contrast. Contrast enhancement of the skin was determined quantitatively by contrast-to-noise ratios (CNR), comparing post- to pre-contrast and dynamic scans (for 6 min, 1 acquisition/min). Patients in the chronic state with sclerodactylia and active inflammation of the hands were considered separately and compared to a control group (n=10) matched according to age. Results. CNR increase after intravenous contrast was significantly higher in patients with active disease (86{+-}16% increase) than sclerosing disease (29{+-}3%, p<0.05) and the control group (4{+-}2%, p<0.05). The dynamic examination showed a significantly slower decrease after the peak rise in the first minute in patients with active disease (CNR 15.4{+-}0.7 to 14.2{+-}1.4) than in those with chronic disease (14.1{+-}0.5 to 11.3{+-}0.9, p<0.05). (orig.) [Deutsch] Zielsetzung der Arbeit war die Quantifizierung der Entzuendungsreaktion der Haut bei an systemischer Sklerodermie erkrankten Patienten mittels kontrastverstaerkter MRT. Material und Methoden. In einer Vorstudie mit 6 Patienten wurden die Sequenzen eines dedizierten Niederfeldmagnetresonanztomographen (Artoscan, Esaote, Genua, Italien) fuer den Kontrastmittelnachweis (0,1 mmol/l Gd-DTPA i.v.) optimiert. Basierend auf dieser Sequenzoptimierung wurden 17 Patienten mit systemischer Sklerodermie (7 Patienten mit sklerosierender, 10

  13. Detection of liver lesions with gadolinium-enhanced VIBE sequence in comparison with SPIO-enhanced MRI; Detektion von Leberlaesionen mit der Gadolinium-verstaerkten VIBE-Sequenz im Vergleich zur SPIO-verstaerkten MRT

    Energy Technology Data Exchange (ETDEWEB)

    Heim, P.; Steiner, P.; Dieckmann, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Schoder, V. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Inst. fuer Medizinische Biometrie und Epidemiologie; Kuhlencordt, R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Allgemein-, Viszeral-, und Thoraxchirurgie

    2003-10-01

    Purpose: Detection of malignant liver lesions with gadolinium-enhanced volumetric interpolated breath-hold examination (VIBE) in comparison with SPIO-enhanced MRT (four different SPIO-enhanced T2w sequences) and histological and imaging follow-up in non-cirrhotic livers at 1.5 T. Patients and methods: Twenty-two patients with suspected focal liver lesions prospectively underwent a gadolinium-enhanced 3D VIBE. Four T2w sequences (HASTE sequence, fast spin-echo-sequence with and without fat-saturation, FLASH 2D gradient echo-sequence) after administration of superparamagnetic iron oxide (SPIO) served as gold standard combined with histological work-up in 17 patients and histological and imaging follow-up in five patients. The image quality was evaluated and the detectability of intrahepatic lesions was rated by the alternative free-response receiver operating characteristic (AFROC) analysis. In addition, the contrast-to-noise ration was compared. Results: Altogether 49 malignant and 35 benign liver lesions were found. Concerning the image quality, VIBE turned out to be of slightly poorer image quality than the SPIO-enhanced examination with HASTE sequence (4.95 vs. 5.0). The fast spin-echo-sequence without fat-saturation demonstrated the highest contrast-to-noise ratio. All sequences showed a comparable certainty in detecting lesion (area under the curve 0.68-0.74) and identifying malignant liver lesions. Conclusions: Despite the small number of patients, VIBE seems to be a comparable, inexpensive and fast method in diagnosing malignant liver lesions. (orig.) [German] Ziel: Detektion maligner Leberlaesionen mit der Gadolinium-verstaerkten 3D-Gradientenecho-Sequenz in Atemanhaltetechnik (VIBE-Sequenz) im Vergleich mit der SPIO-verstaerkten MRT (vier verschiedene SPIO-verstaerkte T2-gew. Sequenzen) sowie histologischen und bildgebenden (Verlaufs-) Untersuchungen in nicht-zirrhotischen Lebern bei 1,5 T. Patienten und Methoden: 22 Patienten mit Verdacht auf maligne

  14. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  15. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  16. CT-guided diagnostic interventions for classification of focal hepatic lesions: A comparison of 14 G- and 18 G-large bore cutting needles; CT-gesteuerte perkutane Biopsien zur Klassifizierung von fokalen Leberlaesionen: Vergleich zwischen 14 G- und 18 G-Stanzbiopsienadeln

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Piroth, W.; Staatz, G.; Adam, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1999-07-01

    Purpose: Analysis and comparison of CT-guided 14- and 18-gauge cutting needle biopsies to accurately assess focal liver disease. Methods: The data of 272 CT-guided biopsies in 268 patients were evaluated retrospectively with regard to sensitivity, specificity and complication rate of the chosen needle caliber in differentiating between benign and malignant disease as well as in the ability to determine specific cell types in the various disorders. A 14-gauge (G) needle was used in 101 (37.1%) cases, in 18-g needle biopsy was performed in 171 (62.9%) cases. The Fisher exact test was employed for statistical analysis. Results: Cutting needle biopsy yielded sufficient histologic material in 267 of 272 (98.2%) cases. Correct diagnosis of malignancy was established in 178 of 191 (93.2%) lesions, 73 of 76 (96.1%) disorders were accurately defined as benign, resulting in an overall value of 94.0% (251 of 267). Of these 251 biopsies a definite histological diagnosis could be determined in 90.6% of the cases employing a 14 G needle and in 90.3% using an 18-g needle. The sensitivity, specificity and rate of complications were 94.8%, 92.0%%, 3.0% for the 14-g needle and 92.7%, 97.6%, 0.6% for the 18-g needle, respectively. There were no statistically significant differences with regard to the needle size. Conclusions: CT-guided biopsy of hepatic lesions with the 18-g biopsy needle is of equivalent diagnostic accuracy when compared with the 14-g needle. (orig.) [Deutsch] Ziel: Analyse und Vergleich CT-gesteuerter Fein- und Grobstanzbiopsien zur definitiven Abklaerung unklarer fokaler Leberveraenderungen. Methoden: Die Daten von insgesamt 272 CT-gefuehrten Punktionen an 268 Patienten wurden retrospektiv hinsichtlich Sensitivitaet, Spezifitaet und Komplikationsrate zur Dignitaetsbestimmung und Faehigkeit zur artdiagnostischen Einordnung unter Beruecksichtigung der Groesse der gewaehlten Punktionsnadel ueberprueft und ausgewertet. In 101 (37,1%) Faellen wurde eine 14 Gauge (G

  17. Current use and possible future applications of the magnetization transfer technique in neuroradiology; Aktuelle Anwendungen und moegliche zukuenftige Applikationen der Magnetisierungstransfer-Technik in der Neuroradiologie

    Energy Technology Data Exchange (ETDEWEB)

    Haehnel, S.; Jost, G.; Sartor, K. [Abt. Neuroradiologie, Neurologische Klinik, Universitaetsklinikum Heidelberg (Germany); Knauth, M. [Abt. Neuroradiologie, Universitaetsklinikum Goettingen (Germany)

    2004-02-01

    Magnetization transfer (MT) imaging is a special MR technique used for selective suppression of the MR signal of protons bound on macromolecules. The most important applications in neuroradiology are (1) detection of subtle changes in otherwise normal-appearing cerebral white matter, for instance in multiple sclerosis (MS), Wallerian degeneration, and hydrocephalus, (2) differentiation of white matter lesions with high signal on T{sub 2}-weighted MR-images, like MS plaques, brain infarctions, and brain edema, (3) follow-up of cerebral white matter diseases using volumetric MT techniques, and (4) improvement in delineating of contrast enhancing brain lesions, such as cerebral metastases. We describe the physical rationale of the MT technique and present the most important current and possible future applications of MT imaging to answer clinical and scientific questions in neuroradiology. (orig.) [German] Die Magnetisierungstransfer-(MT)-Technik ist ein spezielles MRT-Verfahren, mit dem selektiv das MR-Signal der an Makromolekuele gebundenen Protonen unterdrueckt werden kann. Die wichtigsten Anwendungen dieser Technik in der Neuroradiologie sind der Nachweis von subtilen Veraenderungen in ansonsten normal erscheinender weisser Hirnsubstanz, wie z.B. bei Multipler Sklerose (MS), Waller'scher Degeneration und Hydrozephalus, die Differenzierung von Laesionen der weissen Substanz, die durchgaengig hohes Signal auf T{sub 2}-gewichteten MRT-Aufnahmen zeigen, wie z.B. MS-Plaques, Hirninfarkte oder Hirnoedem, die Verlaufskontrolle von Erkrankungen der weissen Substanz mit der volumetrischen MT-Technik, und die Verbesserung der Abgrenzbarkeit kontrasmittelaufnehmender Hirnlaesionen wie Hirnmetastasen. Wir beschreiben die MR-physikalischen Grundlagen der MT-Technik und stellen die wesentlichen aktuellen und moeglichen zukuenftigen Anwendungen zur Beantwortung klinischer und wissenschaftlicher Fragestellungen in der Neuroradiologie vor. (orig.)

  18. Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

    International Nuclear Information System (INIS)

    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J.-J.; Hou, X.-L.; Yang, X.-B.; Chen, J.-H.; Chen, Y.-D.

    2013-01-01

    Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as “non-assessable”. The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

  19. Early alterations in the hip joint following epiphysiolysis for slipped femoral head. Results of an MRI study; Fruehveraenderugen im Hueftgelenk nach Epiphysiolysis capitis femoris. MRT-Untersuchungsergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Stoever, B. [Freiburg Univ. (Germany). Radiologische Klinik; Sigmund, G. [Freiburg Univ. (Germany). Radiologische Klinik; Huhle, P. [Freiburg Univ. (Germany). Orthopaedische Abteilung; Zwack, P. [Freiburg Univ. (Germany). Orthopaedische Abteilung; Reichert, A. [Freiburg Univ. (Germany). Orthopaedische Abteilung; Langer, M. [Freiburg Univ. (Germany). Radiologische Klinik

    1994-01-01

    With the aim of detecting patients at risk of developing coxarthritis, 34 patients were investigated prospectively by MRI 6-14 years after epiphysiolysis for slipped capital femoral head. In particular, cartilage changes were analysed by gradient-echo sequences. In 40% of the hip joints investigated cartilaginous lesions were present, detectable as irregularity and flattening of contour and more rarely as changes in signal intensity. In contrast, only 18% of the radiographs available revealed any pathology. When pelvic X-rays are normal or reveal slight sclerosis, cartilaginous lesions on MRI are considered early signs of coxarthrosis. This combination was seen especially often in patients with a primarily high angle of dislocation and in those who needed treatment by reposition or osteotomy. Only in 8 of the 17 hip joints showing sclerosis on conventional radiograms, sclerosis was also diagnosed by MRI, possibly because of partial volume and susceptibility effects at high field strength. Even with limited spatial resolution, cartilage examinations is warranted in young patients in whom early osteoarthritis can be expected. (orig.) [Deutsch] Mit dem Ziel, Veraenderungen am Hueftgelenk bei Patienten mit Arthroserisiko rechtzeitig zu erfassen, wurden 34 Patienten 6-14 Jahre nach einer Epiphysiolysis capitis femoris mittels MRT im Hochfeld bei 2/T nachuntersucht. Insbesondere sollten anhand der `FLASH`-Gradientenechosequenzen Knorpelveraenderungen analysiert werden. In 40% der untersuchten Hueftgelenke lagen Knorpellaesionen vor, sichtbar als Verduennung der Knorpelschicht, Konturunregelmaessigkeit und seltener als Signalintensitaetsveraenderungen. Dagegen waren nur 18% der vorhandenen Roentgenbefunde eindeutig pathologisch. Die kernspintomographisch sichtbaren Laesionen des Knorpels sind bei normalem Roentgenbild als Fruehveraenderungen zu werten und waren haeufiger bei Patienten mit primaer hohem Dislokationswinkel nachweisbar wie auch bei Patienten, bei denen eine

  20. Negative spiral CT in acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, T.; Olausson, A. [Karolinska Hospital, Stockholm (Sweden). Dept. of Thoracic Radiology; Johnsson, H. [Karolinska Hospital, Stockholm (Sweden). Dept. of Internal Medicine; Nyman, U. [County Hospital, Trelleborg (Sweden). Dept. of Radiology; Aspelin, P. [Huddinge Univ. Hospital (Sweden). Dept. of Radiology

    2002-09-01

    Purpose: To retrospectively evaluate the clinical outcome of non-anticoagulated patients with clinically suspected acute pulmonary embolism (PE) and no symptoms or signs of deep venous thrombosis (DVT) following a negative contrast medium-enhanced spiral CT of the pulmonary arteries (s-CTPA). Material and Methods: During a 24-month period, 739 of 751 patients underwent s-CTPA with acceptable diagnostic quality for clinically suspected acute PE. All patients who had a CT study not positive for PE were followed up with a questionnaire, a telephone interview and review of all medical reports, including autopsies and death certificates for any episodes of venous thromboembolism (VTE) during a 3-month period. Results: PE was diagnosed in 158 patients. Of the remaining 581 patients with a negative s-CTPA, 45 patients were lost to follow-up. 88 patients were excluded because of anticoagulation treatment (cardiac disorder n=32, chronic VTE or acute symptomatic DVT n=31, PE diagnosed at pulmonary angiography n=1, thrombus prophylaxis during diagnostic work-up or other reasons than VTE n=24) and 7 patients undergoing lower extremity venous studies because of symptoms of DVT (all negative). Thus, 441 patients with a negative s-CTPA and no DVT symptoms, venous studies or anticoagulant treatment constituted the follow-up cohort. Four of these patients had proven VTE (all PE) during the 3-month follow-up period. Two of the PE episodes contributed to the patient's death. Conclusion: Patients with clinically suspected acute PE, no symptoms or signs of DVT and a negative single slice s-CTPA using 3-5 mm collimation, may safely be left without anticoagulation treatment unless they are critically ill, have a limited cardiopulmonary reserve and/or if a high clinical suspicion remains.

  1. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    International Nuclear Information System (INIS)

    Mastora, I.; Remy-Jardin, M.; Remy, J.; Suess, C.; Scherf, C.; Guillot, J.P.

    2001-01-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  2. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, I.; Remy-Jardin, M.; Remy, J. [Dept. of Radiology, University Center Hospital Calmette, Lille (France); Medical Research Group, Lille (France); Suess, C.; Scherf, C. [Siemens Medical Systems, Forcheim (Germany); Guillot, J.P. [Dept. of Radiology, University Center Hospital Calmette, Lille (France)

    2001-04-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  3. Spiral computed tomography phase-space source model in the BEAMnrc/EGSnrc Monte Carlo system: implementation and validation

    International Nuclear Information System (INIS)

    Kim, Sangroh; Yoshizumi, Terry T; Yin Fangfang; Chetty, Indrin J

    2013-01-01

    Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan—scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the ‘ISource = 8: Phase-Space Source Incident from Multiple Directions’ in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the

  4. Spiral computed tomography phase-space source model in the BEAMnrc/EGSnrc Monte Carlo system: implementation and validation.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry T; Yin, Fang-Fang; Chetty, Indrin J

    2013-04-21

    Currently, the BEAMnrc/EGSnrc Monte Carlo (MC) system does not provide a spiral CT source model for the simulation of spiral CT scanning. We developed and validated a spiral CT phase-space source model in the BEAMnrc/EGSnrc system. The spiral phase-space source model was implemented in the DOSXYZnrc user code of the BEAMnrc/EGSnrc system by analyzing the geometry of spiral CT scan-scan range, initial angle, rotational direction, pitch, slice thickness, etc. Table movement was simulated by changing the coordinates of the isocenter as a function of beam angles. Some parameters such as pitch, slice thickness and translation per rotation were also incorporated into the model to make the new phase-space source model, designed specifically for spiral CT scan simulations. The source model was hard-coded by modifying the 'ISource = 8: Phase-Space Source Incident from Multiple Directions' in the srcxyznrc.mortran and dosxyznrc.mortran files in the DOSXYZnrc user code. In order to verify the implementation, spiral CT scans were simulated in a CT dose index phantom using the validated x-ray tube model of a commercial CT simulator for both the original multi-direction source (ISOURCE = 8) and the new phase-space source model in the DOSXYZnrc system. Then the acquired 2D and 3D dose distributions were analyzed with respect to the input parameters for various pitch values. In addition, surface-dose profiles were also measured for a patient CT scan protocol using radiochromic film and were compared with the MC simulations. The new phase-space source model was found to simulate the spiral CT scanning in a single simulation run accurately. It also produced the equivalent dose distribution of the ISOURCE = 8 model for the same CT scan parameters. The MC-simulated surface profiles were well matched to the film measurement overall within 10%. The new spiral CT phase-space source model was implemented in the BEAMnrc/EGSnrc system. This work will be beneficial in estimating the spiral

  5. [Die baltischen Lande im Zeitalter der Reformation und Konfessionalisierung : Livland, Estland, Ösel, Ingermanland, Kurland und Lettgallen : Stadt, Land und Konfession 1500-1721. Teil 4. Hrsg. von Matthias Asche, Werner Buchholtz und Anton Schindlin

    Index Scriptorium Estoniae

    Maasing, Madis, 1984-

    2013-01-01

    Arvustus: Die baltischen Lande im Zeitalter der Reformation und Konfessionalisierung : Livland, Estland, Ösel, Ingermanland, Kurland und Lettgallen : Stadt, Land und Konfession 1500-1721. Teil 4. (Katholisches Leben und Kirchenreform im Zeitalter der Glaubensspaltung, 72). Hrsg. von Matthias Asche, Werner Buchholtz und Anton Schindling. Verlag Aschendorff. Münster 2012

  6. Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey

    International Nuclear Information System (INIS)

    Brix, G.; Nagel, H.D.; Stamm, G.; Veit, R.; Lechel, U.; Griebel, J.; Galanski, M.

    2003-01-01

    Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case. (orig.)

  7. Correlation between spiral CT features of pericolic infiltration and tumor angiogenesis in colorectal carcinoma

    International Nuclear Information System (INIS)

    Zhang Ruiping; Li Jianding

    2007-01-01

    Objective: To investigate the correlation of spiral CT (SCT) features with pathology, microvessel density (MVD), expression of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2( MMP-2) in colorectal carcinoma. Methods: Forty patients with colorectal carcinoma confirmed by operation were examined by SCT. The resected tumor specimens were immunohistochemically stained for the expression of VEGF, MMP-2 and the calculation of MVD. Results: The accuracy of SCT in depicting the pericolic and wall infiltration was 92.5%. The metastasis rates of colorectal cancer with pericolic infiltration and wall infiltration were 75.0% and 33.3%, respectively, the differences were statistically significant between the two groups (P<0.05). The differences of CT enhancement value, MVD, expressions of VEGF and MMP-2 between the two groups were statistically significant (P<0.05). The enhancement degree of CT had a positive correlation with MVD (P<0.05). Conclusion: SCT is accurate for depicting pericolic and wall infiltration, pericolic infiltration in colorectal carcinoma indicates the tendency of metastasis. The enhancement degree of CT might be used to quantitatively evaluate the tumor angiogenesis, expressions of VEGF and MMP-2 and MVD are closely correlated with the infiltration of colorectal cancer. (authors)

  8. Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning

    International Nuclear Information System (INIS)

    Ford, E.C.; Mageras, G.S.; Yorke, E.; Ling, C.C.

    2003-01-01

    We describe a method for generating CT images at multiple respiratory phases with a single spiral CT scan, referred to as respiratory-correlated spiral CT (RCCT). RCCT relies on a respiration wave form supplied by an external patient monitor. During acquisition this wave form is recorded along with the initiation time of the CT scan, so as to 'time stamp' each reconstructed slice with the phase of the respiratory cycle. By selecting the appropriate slices, a full CT image set is generated at several phases, typically 7-11 per cycle. The CT parameters are chosen to optimize the temporal resolution while minimizing the spatial gap between slices at successive respiratory cycles. Using a pitch of 0.5, a gantry rotation period of 1.5 s, and a 180 degree sign reconstruction algorithm results in ∼5 mm slice spacing at a given phase for typical respiration periods, and a respiratory motion within each slice that is acceptably small, particularly near end expiration or end inspiration where gated radiotherapy is to occur. We have performed validation measurements on a phantom with a moving sphere designed to simulate respiration-induced tumor motion. RCCT scans of the phantom at respiratory periods of 4, 5, and 6 s show good agreement of the sphere's motion with that observed under fluoroscopic imaging. The positional deviations in the sphere's centroid between RCCT and fluoroscopy are 1.1±0.9 mm in the transaxial direction (average over all scans at all phases ±1 s.d.) and 1.2±1.0 mm in the longitudinal direction. Reconstructed volumes match those expected on the basis of stationary-phantom scans to within 5% in all cases. The surface distortions of the reconstructed sphere, as quantified by deviations from a mathematical reference sphere, are similar to those from a stationary phantom scan and are correlated with the speed of the phantom. A RCCT scan of the phantom undergoing irregular motion, demonstrates that successful reconstruction can be achieved even with

  9. Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

    International Nuclear Information System (INIS)

    Frennby, B.; Almen, T.

    2001-01-01

    The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r=0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol). (orig.)

  10. Value of radiographic examination of the knee joint for the orthopedic surgeon; Wertigkeit der radiologischen Bildgebung beim Kniegelenk fuer den Orthopaeden

    Energy Technology Data Exchange (ETDEWEB)

    Pietsch, M.; Hofmann, S. [Allgemeines und Orthopaedisches LKH Stolzalpe (Austria). Abteilung fuer Orthopaedie und orthopaedische Chirurgie

    2006-01-01

    Extended radiographic examinations offer excellent options for diagnosis and strategy for treatment of the knee joint. The whole-leg radiograph is indispensable in measuring alignment for osteotomy or total knee arthroplasty (TKA). Fluoroscopically assisted varus-valgus stress radiographs provide the possibility for verifying mechanical function of the implanted knee prosthesis. Ultrasound examinations have been widely replaced by magnetic resonance imaging (MRI). MRI is the golden standard to examine intra-articular structures of the knee (meniscus, ligaments, cartilage) and surrounding soft tissue. For evaluating femoral and tibial torsion and determining axial rotation of TKA, computed tomography (CT) is best qualified. Imaging of the patellofemoral joint (patella instability) is difficult; CT scans in combination with true lateral radiographs seem to be helpful. (orig.) [German] Die erweiterte Roentgendiagnostik bietet gute Moeglichkeiten der Diagnose und Therapieplanung beim Kniegelenk. Das Ganzbeinroentgen ist unabdingbar zur Achsvermessung bei der Planung einer Umstellungsosteotomie oder der Implantation einer Knietotalendoprothese (KTEP). Varus-/Valgusaufnahmen unter Bildwandler gestatten die Ueberpruefung der Mechanik einer liegenden KTEP. Sonographische Untersuchungen des Kniegelenks sind weitgehend durch die Magnetresonanztomographie (MRT) ersetzt. Die MRT ist die Methode der Wahl zur Beurteilung der Kniebinnenstrukturen (Meniskus, Baender, Knorpel) und der umgebenden Weichteile. Zur Bestimmung der Torsion von Femur und Tibia sowie der Rotation der Komponenten einer KTEP ist die Computertomographie (CT) am besten geeignet. Die Beurteilung des Femorpatellargelenks (Patellainstabilitaet) ist schwierig, am vielversprechendsten erscheint die CT in Kombination mit streng seitlichen Roentgenbildern. (orig.)

  11. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    International Nuclear Information System (INIS)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N.

    2006-01-01

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results

  12. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N. [Medical Univ. of Bologna, S. Orsola-Malpighi Policlinic (Italy). Dept. of Radiology

    2006-10-15

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results.

  13. Diagnosis of colorectal tumors; Diagnostik von kolorektalen Tumoren. Mehrschichtcomputertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Pegios, W.; Jacobi, V.; Schaefer, S.; Abolmaali, N.; Luboldt, W. [Institut fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Universitaet Frankfurt (Germany)

    2003-02-01

    With the introduction of multislice CT extensive volumetric data sets can be quickly acquired in high spatial resolution. The high spatial resolution reduces partial volume effects and enables multiplanar reconstructions. Regarding the colorectum this means that the colon can be assessed if the colon is sufficiently cleaned and distended, and that transmural infiltration of colorectal carcinoma and liver metastases can be better detected. T-staging of colon cancer is less important than T-staging of rectal cancer. Based on the higher contrast MRI is superior to CT in T-staging of rectal cancer and in the differentiation between scarring tissue and recurrence of carcinoma. (orig.) [German] Mit Einfuehrung der Mehrschicht-CT lassen sich umfangreiche Volumendatensaetze schnell und mit hoher Aufloesung erfassen. Die hohe raeumliche Aufloesung reduziert Teilvolumeneffekte und ermoeglicht multiplanare Rekonstruktionen. In Bezug auf das Kolorektum bedeutet dies, dass das Kolon bei ausreichender Darmreinigung und -distension gut beurteilbar ist und transmurale Infiltrationen von kolorektalen Karzinomen sowie Lebermetastasen leichter zu erkennen sind.Bei Kolonkarzinomen hat das T-Staging weniger klinische Relevanz als bei Rektumkarzinomen. Aufgrund des hoeheren Kontrasts ist die MRT der CT im T-Staging von Rektumkarzinomen sowie in der Unterscheidungzwischen Narben- und Rezidivtumorgewebe ueberlegen. (orig.)

  14. Evaluation of the nutcracker syndrome using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Shi Heshui; Fan Yanqing; Han Ping; Zhou Chengkai; Zhao Long; Wu Hongying; Yu Qun; Liu Yonghua

    2007-01-01

    Objective: To evaluate the ability of multi-slice spiral CT (MSCT) in diagnosing nutcracker syndrome(NCS). Methods: MSCT angiography (MSCTA) or contrast enhanced CT data of 16 patients clinically diagnosed as NCS( patient group) and 80 subjects with nomal kidneys and renal vessels (control group ) were retrospectively reviewed. The anatomy, course and relationship to the adjacent structure of left renal vein (LRV) and its branches were observed. The angle (a) between SMA and the abdominal aorta (AA), the distance (d) between SMA and AA at the level of LRV passing through, the cross areas of LRV through the angle (s1) and at the largest diameter near the renal hilar (s2) were measured and the ratio(q) of s2 to sl was calculated. Results: All LRVs were compressed and showed dilated, 7 of them with the genesial gland vein enlargement. The causes of the LRV narrowing and obstruction were small angle (a) in 14 patients and abnormal path of LRV posterior to AA in 2 cases. The value of a,d,s1,s2 and q in the patient group and the control group were: (21±4) degree, (0.53±0.11) cm, (0.28±0.06) cm 2 , (1.42±0.48) cm 2 , 5.26 and (52±24) degree, (1.39±0.70) cm, (0.81±0.32) cm 2 , (1.21±0.35) cm 2 , 1.52, respectively. The differences were significant between the two groups (P< 0.05). Conclusion: The appearance and its path of the LRV could be well delineated on the MSCT, allowing a accurate evaluation of the LRV narrowing non-invasively. (authors)

  15. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

    International Nuclear Information System (INIS)

    Jarry, G; De Marco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-01-01

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  16. Functional magnetic resonance imaging with ultra-high fields; Funktionelle Magnetresonanztomographie bei ultrahohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Medizinische Universitaet Wien, Zentrum fuer Medizinische Physik und Biomedizinische Technik, Wien (Austria); Fischmeister, F.P.S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Universitaet Wien, Fakultaet fuer Psychologie, Wien (Austria)

    2010-02-15

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) stellt zurzeit die wichtigste Methode zur nichtinvasiven Funktionslokalisation im Gehirn dar. Mit der Verfuegbarkeit von MRT-Geraeten mit Magnetfeldstaerken von 4 Tesla (T) und darueber ergeben sich neue Moeglichkeiten, mittels fMRT die neuronale Aktivitaet in bislang unerreichter Genauigkeit zu untersuchen. In diesem Artikel zeigen wir anhand mehrerer Studien bei 7 T, in wieweit die Zugewinne an Sensitivitaet und Spezifitaet verwendet werden koennen, um die bisherigen Grenzen der fMRT-Aufloesung in raeumlicher und zeitlicher Hinsicht auszuweiten. Die neuen Herausforderungen, die mit dem Schritt zu ultrahohen Magnetfeldern einhergehen, werden dabei ebenso diskutiert wie moegliche Ansaetze zu deren Loesung. (orig.)

  17. Spontanes Liquorunterdrucksyndrom - Übersicht und Fallpräsentation anhand von fünf Patienten

    OpenAIRE

    Richter S; Riedl M; Mickocki J; Parigger S; Hartmann W; Brücke T

    2006-01-01

    Das spontane Liquorunterdrucksyndrom (SLUDS) wurde erstmals 1938 beschrieben: Leitsymptom ist ein lageabhängiger, orthostatischer Kopfschmerz, der durch aufrechte Position provoziert wird. Ursächlich besteht ein vermindertes Liquorvolumen mit absolut oder relativ vermindertem Liquordruck, bei vorwiegend zervikalen oder zervikothorakalen Liquorleckagen. Diagnostisch stehen MRT mit Gadoliniumgabe und die Liquorszintigraphie zur Verfügung. Die Therapie der Wahl ist ausreichende Flüssigkeitszu...

  18. Blind deblurring of spiral CT images - comparative studies on edge-to-noise ratios

    International Nuclear Information System (INIS)

    Jiang Ming; Wan Ge; Skinner, Margaret W.; Rubinstein, Jay T.; Vannier, Michael W.

    2002-01-01

    A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the phantom study, it is shown that all the ratios share similar properties, validating the blind deblurring algorithm. The image fidelity improvement varies from 29% to 33% for different ratios, according to the root mean square error (RMSE) criterion; the optimal iteration number determined for each ratio varies from 25 to 35. Those ratios that are associated with most satisfactory performance are singled out for the image fidelity improvement of about 33% in the numerical simulation. After automatic blind deblurring with the selected ratios, the spatial resolution of CT is substantially refined in all the cases tested

  19. Radiation dosimetry and its influencing factors for the multi-detector/slice spiral CT

    International Nuclear Information System (INIS)

    Bai Mei; Zheng Junzheng

    2008-01-01

    The Multi-Detector/Slice Spiral Computed Tomography (MDCT/MSCT)reflects the new progress in equipment and technology for radiology. Its popularized application demonstrates its advantages for clinical diagnosis. With the continuous development and growing uses of the MDCT/MSCT, the medical exposure of the patients and public has also been increasing. Therefore, assessment of the radiation dose and radiation risk from X-CT has become an increasingly important concern that should be addressed. Thus, this paper summarizes the main characteristics of the MDCT/MSCT emphasizing particularly on the radiation dosimetry, and reviews the expressions and measures of radiation dose in the MDCT/MSCT. In addition, main factors that influence radiation dose from the MDCT/MSCT are also discussed. A proper grasp of its radiation dosimetry and assessment method can significantly help radiologists, health physicists, medical physicists, X-CT engineers and manufacturers improve the management of radiation dose while optimizing the image quality in the MDCT/MSCT. (authors)

  20. Angiogenesis in hepatocellular carcinoma: correlation of single-level dynamic spiral CT scans in arterial phase and expression of α-smooth muscle actin

    International Nuclear Information System (INIS)

    Liu Yan; Min Pengqiu; Chen Weixia; Zhang Lin

    2005-01-01

    Objective: To investigate the correlation between the single-level dynamic spiral CT scans (SDCT) of hepatocellular carcinoma (HCC) in arterial phase (AP) and the immunohistochemistry expression of α-smooth muscle actin (ASMA). Methods: 33 cases of suspected HCC undergoing spiral CT plain scan of the whole liver, the single-level dynamic scan of the target level of lesion in AP and finally the whole liver scan in portal-venous phase before operations and proved after were included into the study. After the SDCT, a time-density curve (T-DC) was drawn according to the density change of the region of interest (ROI) of the tumor parenchyma with some parameters calculated, and signs of enhancement evaluated. Slices of post-operation specimen underwent hemotoxylin-eosin (HE) and ASMA immunohistochemistry staining. Then the slices were evaluated with emphases on the ASMA-positive neovasculatures in the parenchyma and mesenchyma of carcinomas, and the average count in a low microscopic field (x 100) was recorded (5 low microscopic field were observed and then an average was calculated.). Finally the immunohistochemistry and histologic results were correlated with image findings. Results: According to the PV of the tumor parenchyma, T-DC was divided into type I, II and III in which the criteria were PV>80, 40 HU< PV< 80 HU and PV<40 HU respectively. In the 33 cases, type I, II and III of T-DC were 3, 17 and 13 cases with PV of 103.30, 57.65 and 33.55 HU respectively. In ASMA immunohistochemistry study, ASMA-positive neovasculatures were devided into type A with a thick wall and B with a thin wall. The mean count of neovasculatures of tumor parenchyma in type I, II and III of T-DC were 10, 4.59 and 1 respectively. Statistically, different types of T-DC were significantly correlated with the count of neovasculatures in the parenchyma of carcinomas (r=-0.567, P<0.01). Homogeneous and inhomogeneous enhancement of carcinomas during SDCT in AP were correlated with the

  1. Measuring of the airway dimensions with spiral CT images: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huibin; Ma Ji; Wu Gang; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To measure the length, angle and their correlation of the main anatomical dimensions of the trachea and bronchus in experimental Japanese white big-ear rabbits with the help of spiral CT 3D images, in order to lay the foundation of treating the airway disorders with stenting in animal experiment. Methods: Multi-slice CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the longitudinal, transversal dimensions of the trachea, the glottis-carina length, the inner diameter and length of bronchi, and the angle formed by bronchial long axis and sagittal section were measured. Results: No significant difference was found in the inner diameters of various parts of the trachea and upper apical bronchi. The angle formed by bronchial long axis and sagittal section were smaller than that of the left ones. And the inner diameters of the right main bronchus was bigger than the left ones. Conclusion: The complex branching structure of the rabbit airway tree can be well displayed on spiral CT 3D images. Through measuring and statistical analysis of the results the authors have got a regressive equation for estimating the value of the inner diameter, length, angle, etc. concerning the airway tree, which is very helpful for providing the useful anatomical parameters in rabbit experiment. (authors)

  2. Meniscus and ligament injuries; Meniskus- und Bandlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Glaser, C.; Trumm, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie (Germany); Scheidler, J.; Heuck, A. [Radiologisches Zentrum Muenchen, Pasing (Germany)

    2006-01-01

    fuer die Arthroseentstehung, und entsprechende Schaedigungen muessen zeitnah und umfassend diagnostiziert werden. Die MRT-Abklaerung mit (T)SE-Sequenzen in allen 3 Hauptebenen als Basisprotokoll ist empfehlenswert. Vor allem fettsupprimierte Sequenzen (STIR/T2w, PD-FS-TSE) sind nuetzlich, da sie sehr sensitiv knochenmarkoedemaehnliche Veraenderungen (BMEP) erfassen. Dieser Befund lenkt oft erst die Aufmerksamkeit des Radiologen auf die - manchmal nur diskreten, weit weniger ins Auge fallenden - zugrunde liegenden Pathologien. In typischer topographischer Verteilung und gibt Aufschluss ueber den Unfallmechanismus und damit Hinweise auf andere assoziierte Verletzungen des Kapsel-Band-Apparats oder der Menisken. BMEP ist sehr ausgedehnt bei Kontusionsverletzungen, bei avulsiven Laesionen jedoch meist sehr diskret. Zu den Zeichen, moeglichen Fallstricken und die Treffsicherheit der Magnetresonanztomographie (MRT) fuer die Diagnose spezifischer Verletzungen wie Meniskus-, Kreuz- oder Kollateralbandrissen existiert eine Fuelle von Literatur. Allerdings ist die kombinierte Verletzung mehrerer der genannten Strukturen haeufig und beeinflusst die Therapieentscheidung. Dementsprechend ist es Aufgabe des Radiologen, ueber die Erfassung einer einzelnen Laesion hinauszugehen und eine umfassende Beschreibung aller verletzten Strukturen zu geben. Voraussetzung dafuer ist die Kenntnis der - manchmal komplexen - Anatomie und typischer Verletzungskonstellationen. (orig.)

  3. An alternative scanning protocol to eliminate perivenous streak artifacts in thoracic spiral computed tomography. The usefulness of ankle vein contrast injection

    International Nuclear Information System (INIS)

    Hara, Masaki; Ogino, Hiroyuki; Itoh, Masato; Ohba, Satoru; Andoh, Keiichi; Kitase, Masanori; Goodman, P.C.

    2001-01-01

    The purpose of this study was to eliminate perivenous streak artifact from contrast-enhanced thoracic spiral CT using superficial ankle vein injection (ankle vein method). Forty-four consecutive inpatients had thoracic spiral CT following ankle vein method and were compared to 30 patients who had conventional antecubital vein injection. Non-ionic 300 mg/mL contrast material were injected at 1-1.5 mL/sec with a power injector. Twenty mL of normal saline was injected immediately thereafter as a flushing bolus. Qualitative scores of perivenous artifact (1 to 5=extensive) and vascular enhancement (1 to 5=excellent) were recorded. Complications were investigated clinically. The mean score of perivenous artifact was 1 with the ankle vein method and 4.4 with the conventional method (P<.0001). Scores of pulmonary artery opacification were almost equal (4.2 and 4.5 respectively, P=.11). No complications were observed. The ankle vein method is an effective method to prevent perivenous artifact during thoracic spiral CT. (author)

  4. MR-guided focused ultrasound. Current and future applications; MR-gesteuerter fokussierter Ultraschall. Aktuelle und potenzielle Indikationen

    Energy Technology Data Exchange (ETDEWEB)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen-Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Napoli, A. [Sapienza Universitaet Rom, Abteilung fuer Radiologie (Department of Radiological Sciences), MRgFUS and Cardiovascular Imaging Unit, Rom (Italy); Matzko, M. [Klinikum Dachau, Abteilung fuer diagnostische und interventionelle Radiologie, Dachau (Germany)

    2013-03-15

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [German] MRT-gesteuerter hochintensiver fokussierter Ultraschall (MRgFUS bzw. MR-HIFU) ist ein nichtinvasives Verfahren zur praezisen Thermoablation eines Zielgewebes. Bei dieser Methode werden benachbarte Gewebe und Organe geschont. Die Kombination des fokussierten Ultraschalls (FUS) mit der MRT zwecks Planung und Monitoring (nahezu) in Echtzeit sowie zur Erfolgskontrolle von Behandlungen traegt wesentlich zur Sicherheit dieser Methode bei. MRgFUS ist klinisch v. a. zur Behandlung von symptomatischen Uterusmyomen etabliert, gefolgt von der palliativen Ablation von Knochenmetastasen. Weitere vielversprechende Anwendungsgebiete des MRgFUS sind die Adenomyose des Uterus, die Behandlung von Prostata-, Mamma- und Lebertumoren sowie der intrakranielle Einsatz. (orig.)

  5. Evaluation of image quality and dose in thoracic spiral CT examination in patients with pulmonary carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Moran-Blanco, L. M.; Rodriguez-Gonzalez, R.; Calzado-Cantera, A.; Arenas de Pablo, A.; Baeza-Trujillo, M.; Cuevas-Ibanez, A.; Garcia-Castano, B.; Gomez-Leon, N.; Turrero-Nogues, A.; Moran-Penco, P.

    2002-01-01

    We have applied criteria for CT quality defined in the European Guidelines to a samples of thoracic CT examinations for the indication of pulmonary carcinoma of 5 institutions of the Community of Madrid that have spiral CT equipment. The selected examinations have been evaluated independently by five radiologists to determine the degree of adherence to the quality criteria for image defined in the Guidelines s for examinations of general thorax. Dosimetric measurements carried out in parallel have served to estimate the values of CT (CTDI w ) dose indices, dose-length product (DLP) and effective dose for every patient. The result show a high global adherence to the quality criteria (96%), with averages per institution being between 94% (in two institutions) and 98% (in three institutions). There are 10 of 16 criteria that are adhered to in all examinations of the sample: those which are not adhered to systematically are: two of visualization (1.1 and 1.4), with 92-96% fulfillment, and four of critical reproduction (2.6; 2.8; 2.9 and 2.10), with percentages of adherence between 91% and 96%. The average CTDI w values per institution are in the interval 12.9-19.1 mGy; those of DLP between 263 and 577 mGy cm and those of effective dose between 4.2 and 9.2 mSv. The DLP-image quality correlation in institutions with the best image quality was null in two of them and direct and moderate in the third. In both institutions with the poorest image: (Author) 20 refs

  6. Anatomic variation in the origin of the main renal arteries: spiral CTA evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beregi, J.P.; Willoteaux, S.; Remy-Jardin, M. [Department of Vascular Radiology, Hopital Cardiologique, 59 - Lille (France); Mauroy, B.; Francke, J.P. [Laboratoire d`Anatomie, Univ. de Lille (France); Mounier-Vehier, C. [Department of Hypertension and Internal Medicine, Hopital Cardiologique, Lille (France)

    1999-09-01

    The aim of this study was to provide quantitative data on the origin and trajectory of the main renal arteries using spiral CT angiography and arteriography. Normal renal artery anatomy was assessed on spiral CT angiography (axial transverse sections and shaded-surface-display reconstructions) in 100 patients referred for renal arteriography who had no significant renal artery stenosis. Two hundred major renal arteries were studied. The vast majority of right (88 %) and left (87 %) renal arteries originated between the lower third of the first lumbar vertebra and the lower border of the second lumbar vertebra. In 50 patients both ostia were at the same level; in the remaining 50 patients, the right ostium was located above the left in 37 patients. On the right, the angle of origin varied from -10 to + 55 (mean + 24 ). On the left, the angle of origin varied from + 30 to -55 (mean -11 ). Spiral CT angiography provides additional anatomic data, notably regarding the angle of origin of the renal arteries, that is potentially useful for planning interventional procedures. (orig.) With 4 figs., 19 refs.

  7. C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions; Transarterielle Chemoperfusion und -embolisation thorakaler Neoplasmen mittels C-Arm CT

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.; Nour-Eldin, N.E.; Lehnert, T.; Mbalisike, E. [Klinikum der Johann-Wolfgang-Goethe-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany)

    2009-09-15

    To evaluate the role of C-arm CT for on-line fluoroscopy in regional transarterial chemoperfusion (TACP) and chemo-embolization (TPCE) of primary and secondary malignant thoracic lesions. From September 2008 to March 2009 a total of 31 patients (20 males and 11 females, average age: 61.7 years, range 22-84 years) with 53 thoracic malignant lesions from different origins (primary or secondary pulmonary carcinoma n=37, pleural mesothelioma n=16) were treated with TACP or TPCE using flat-detector CT (FD-CT). C-arm CT of the latest generation was used to localize the lesion before local chemotherapy (Artis Zeego, Siemens, Erlangen). For TACP a 220 rotation and a volume of 150 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 12 ml/s was used. For TPCE a volume of 75 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 3 ml/s was used. TPCE C-arm CT allowed the evaluation of the degree of perfusion of the tumor and the geographic areas of enhancement correlated with the post-interventional lipiodol uptake in MSCT. In TACP the intercostal arteries involved could be visualized and in 30% of interventions the catheter had to be repositioned for the following intervention. C-arm CT provides additional information on the vascular characteristics and perfusion of pulmonary lesions resulting in a change of interventional strategy in a relevant number of patients. (orig.) [German] Ziel der Arbeit war die Evaluation der Wertigkeit der C-Arm CT fuer die online gesteuerte regionale transarterielle Chemoperfusion (TACP) und die transpulmonale Chemoembolisation (TPCE) primaerer und sekundaerer thorakaler Neoplasmen Von September 2008 bis Maerz 2009 wurden 31 Patienten (11 Frauen/20 Maenner, Durchschnittsalter 61,7 Jahre) mit 53 unterschiedlichen thorakalen Neoplasmen (primaere oder sekundaere Lungenkarzinome [n=37], Pleuramesotheliome [n=16]) mittels TACP oder TPCE unter Einsatz der Flachdetektortechnologie (FD-CT) behandelt. Alle Behandlungen erfolgten an einem C

  8. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  9. Autoimmune pancreatitis. An update; Autoimmunpankreatitis. Ein Update

    Energy Technology Data Exchange (ETDEWEB)

    Helmberger, T. [Klinikum Bogenhausen, Staedt. Klinikum, Institut fuer Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Muenchen (Germany)

    2016-04-15

    have to be aware of the clinical, serological and histological parameters for AIP in order to guide clinicians towards the correct diagnosis. Only in this way can the highly efficient steroid therapy be initiated and otherwise possibly severe forms of therapy be avoided. (orig.) [German] Die Autoimmunpankreatitis (AIP) ist eine seltene Erkrankung, deren Verstaendnis sich in den letzten Jahren deutlich vertieft hat. Die haeufigste Form, die Typ-1-AIP, gehoert zu den IgG4-assoziierten Erkrankungen, die viel seltenere Typ-2-AIP ist hiervon zu differenzieren und steht mit chronisch entzuendlichen Darmerkrankungen in Verbindung. Bildgebend und klinisch besteht eine Ueberlappung zum Pankreaskarzinom. Aufgabe der Bildgebung und weiterer Parameter wie Serologie und Histologie ist es deshalb, eine Differenzierung zwischen den beiden Erkrankungsentitaeten zu schaffen, um sie jeweils der adaequaten Therapie zuzufuehren und die geringe, aber letztlich unnoetige Anzahl an Pankreatektomien wegen einer AIP zu verhindern. Die Diagnose der AIP ist komplex, wobei sich in den letzten Jahren die Konsensuskriterien der International Association of Pancreatology als Entscheidungsparameter vielfach durchgesetzt haben. Diese umfassen 5 Kardinalkriterien und ein therapeutisches Kriterium. Unter Verwendung dieser Parameter kann die AIP mit einer Sensitivitaet von 84,9 %, Spezifitaet von 100 % und Treffsicherheit von 93,8 % diagnostiziert werden. Die Diagnose einer AIP setzt sich aus verschiedenen Parametern zusammen, von denen 2 die Bildgebung betreffen. Wie bei der sonstigen Diagnostik des Pankreas sind dies Ultraschall, CT und MRT. Wesentlich fuer die Differenzialdiagnose ist der Ausschluss sekundaerer Malignitaetskriterien, wofuer CT und MRT etabliert sind. Das wesentliche diagnostische Kriterium der Histologie erfordert ausreichend Material, was in der Regel durch eine endoskopische Feinnadelpunktion (FNP) nicht gewonnen werden kann. Fuer die Identifikation des optimalen Punktionsorts und

  10. A new approximate algorithm for image reconstruction in cone-beam spiral CT at small cone-angles

    International Nuclear Information System (INIS)

    Schaller, S.; Flohr, T.; Steffen, P.

    1996-01-01

    This paper presents a new approximate algorithm for image reconstruction with cone-beam spiral CT data at relatively small cone-angles. Based on the algorithm of Wang et al., our method combines a special complementary interpolation with filtered backprojection. The presented algorithm has three main advantages over Wang's algorithm: (1) It overcomes the pitch limitation of Wang's algorithm. (2) It significantly improves z-resolution when suitable sampling schemes are applied. (3) It avoids the waste of applied radiation dose inherent to Wang's algorithm. Usage of the total applied dose is an important requirement in medical imaging. Our method has been implemented on a standard workstation. Reconstructions of computer-simulated data of different phantoms, assuming sampling conditions and image quality requirements typical to medical CT, show encouraging results

  11. MRI for therapy control in patients with tetralogy of Fallot; MRT zur Therapiekontrolle bei Patienten mit Fallot-Tetralogie

    Energy Technology Data Exchange (ETDEWEB)

    Theisen, D.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Dalla Pozza, R.D. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Abteilung fuer Kinderkardiologie und Paediatrische Intensivmedizin, Kinderherzzentrum, Muenchen (Germany); Malec, E. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Herzchirurgische Klinik, Kinderherzzentrum, Muenchen (Germany)

    2011-01-15

    With prevalences ranging from 0.26 to 0.8 permille of all live births tetralogy of Fallot (TOF) is the most common congenital heart disease with primary cyanosis. Due to improvements in surgical techniques, nearly all patients can nowadays expect to reach adulthood. After surgical repair, pulmonary regurgitation (PR) occurs in almost every child and is an important contributing factor in long-term morbidity and mortality. Cardiac magnetic resonance imaging is well established for functional assessment and flow measurements and is an ideal tool for serial post-surgical follow-up examinations, as it is non-invasive and does not expose patients to ionizing radiation. The timing of pulmonary valve replacement is crucial as right ventricular (RV) volumes have only proven to normalize when preoperative end-diastolic volumes are <170 ml/m{sup 2} and end-systolic volumes are <85 ml/m{sup 2}. After surgical repair up to 15% of patients have residual or recurrent pulmonary artery stenosis. Distal pulmonary branch stenosis can aggravate PR and lead to right heart failure due to combined pressure and volume overload. Therefore, it has to be diagnosed in time and treated by angioplasty with or without stenting. (orig.) [German] Die Fallot-Tetralogie (TOF) ist mit einer Praevalenz zwischen 0,26 und 0,8 permille aller Lebendgeburten der haeufigste Herzfehler mit primaerer Zyanose. Durch verbesserte Operationstechniken erreichen heute nahezu alle Patienten das Erwachsenenalter. Bei fast allen Patienten tritt eine postoperative Pulmonalinsuffizienz (PI) auf, die entscheidenden Einfluss auf die langfristige Morbiditaet und Mortalitaet hat. Die kardiale Magnetresonanztomographie (MRT) ist fuer Quantifizierung von Ventrikelfunktion und Klappeninsuffizienzen etabliert und aufgrund ihrer fehlenden Invasivitaet und Strahlenexposition sehr gut fuer regelmaessige Verlaufskontrollen der heranwachsenden Patienten geeignet. Insbesondere der Zeitpunkt fuer einen Pulmonalklappenersatz darf

  12. The selection of window width and levels for measuring the airway dimensions with spiral CT scan: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huuibing; Wu Gang; Ma Ji; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To investigate the optimal window width and window level for measuring the airway dimensions with spiral CT scan in Japanese white big-ear rabbits so as to lay the foundation for airway stenting in animal experiments. Methods: Multi-slice spiral CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the anteroposterior and transversal diameter of the thoracic trachea, the anteroposterior diameter of the right and left bronchus were measured with lung window, mediastinum window and special fat window separately. The revealing rate of the tracheal wall and the measuring results in different windows and levels were recorded and compared with the anatomical data. The differences of the relevant data were statistically analyzed. Results: With lung window, the tracheal wall was well demonstrated, but the relevant data were smaller than that with mediastinum window. With mediastinum window, the data were bigger and the tracheal wall border appeared blurred. The results obtained with fat window were close to the actual anatomical data. Conclusion: For accurately measuring the anteroposterior and transversal diameter of the thoracic trachea in Japanese white big-ear rabbits with multi- slice spiral CT scan, fat window should be adopted, which is helpful for the preparation of tracheal and bronchial stents. (authors)

  13. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  14. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  15. CT-guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver malignancies; CT-gesteuerte Brachytherapie. Eine neue perkutane Technik zur interstitiellen Ablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J.; Wust, P.; Stohlmann, A.; Beck, A.; Cho, C.H.; Pech, M.; Wieners, G.; Spors, B.; Werk, M.; Rosner, C.; Haenninen, E.L.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany)

    2004-05-01

    Purpose: to assess safety and efficacy of CT-guided brachytherapy of liver malignancies. Patients and methods: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a {sup 192}Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size {>=} 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. Results: the mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. Conclusion: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization. (orig.) [German] Ziel: Analyse der Sicherheit und Effektivitaet CT-gesteuerter Brachytherapie zur Ablation von Lebermalignomen. Patienten und Methodik: 21 Patienten mit 21 Lebermalignomen (19 Metastasen, zwei primaere Lebermalignome) wurden mit perkutaner, CT-gesteuerter interstitieller Brachytherapie mit {sup 192}Ir behandelt. Alle Patienten wiesen Umstaende auf, die eine bildgefuehrte thermische Ablation mit Radiofrequenz oder laserinduzierter Thermotherapie (LITT) einschraenkten

  16. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  17. Technique and value of three dimensional reconstruction of stones in the renal pelvis using spiral CT

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Pentenrieder, M.; Kohz, P.; Englmeier, H.K.; Schmeller, N.

    1994-01-01

    5 patients with staghorn calculi in the renal pelvis were examined by spiral CT. From the raw data three dimensional reconstructions of the stones were obtained. In all patients it was possible to compare the three dimensional model with the stone following performance of percutaneous lithopaxy and endoscopic removal of the fragments. In all cases the three dimensional reconstruction provided a realistic image of the stones and was of practical value for the urologist for preoperative diagnosis and intraoperative control. (orig.) [de

  18. Value of different MR techniques in diagnosis of degenerative disorders of the hyaline cartilage - in vitro study on 50 joint specimens of the knee with 1.5 T; Vergleich von verschiedenen MRT-Techniken in der Diagnose von degenerativen Knorpelerkrankungen - in-vitro-Studie an 50 Gelenkpraeparaten des Knies bei 1,5 T

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, G. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Heinrichs, C. [Klinikum der Univ. Giessen (Germany). Inst. fuer Pathologie; Juergensen, I. [Klinikum der Univ. Giessen (Germany). Orthopaedische Klinik; Rominger, M. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Scheiter, A. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Rau, W.S. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie

    1997-05-01

    Purpose: An experimental study was performed on joint specimens of the knee to assess the advantages and disadvantages of 14 generally available sequences in cartilage imaging. Methods: Each of the 50 surgically exposed cadaveric joints of the knee was examined by the following sequences: T{sub 1}, proton- and T{sub 2} weighted spin echo(SE) sequences, proton- and T{sub 2} weighted Turbo-SE, T{sub 1} weighted SE with fat suppression, MTC combined with T{sub 1}-weighted SE and T{sub 2} weighted FLASH-2 D, STIR, FISP-3 D, FLASH-3 D (with fat suppression), and MR arthrography. We assessed the image quality by a scale, signal to noise-ratio of cartilage and joint fluid, and the accuracy in detection of cartilage lesions. Pathology and arthroscopy were reference methods to MRI, and demonstrated grade 1-4 lesions on 186 of 300 joint facettes. Results: Advanced stages of cartilage lesions (65 grade 3 and 4 lesions) were detected by standard SE sequences in 67-94%. Application of volume techniques (FISP-3 D, FLASH-3 D), high definition matrix (512 pixel), MTC with FLASH-2 D and MR-arthrography improved the sensitivity up to 82-100%. Superficial lesions (65 grade 2 lesions) were demonstrated in 3-38%, and on MR arthrography in 45%. Structural changes (56 Grade 1 lesions) were recorded on MRI in only 10%. Conclusions: With regard to standard SE sequences, the detectability of cartilage lesions can be improved by techniques that use 512 matrices, selective cartilage imaging, and volume acquisition. (orig.) [Deutsch] Ziel: In einer experimentellen Studie an Gelenkpraeparaten des Knies wurden die Vor- und Nachteile von 14 allgemein verfuegbaren MRT-Sequenzen in der Knorpeldiagnostik dargestellt. Methode: 50 chirurgisch exstirpierte Kniegelenkpraeparate wurden nacheinander mit folgenden Techniken untersucht: Klassische Spin-Echo(SE)-Sequenz in T{sub 1}-, Protonen- und T{sub 2}-Wichtung, Turbo-SE in Protonen- und T{sub 2}-Wichtung, Fettsuppression mit T{sub 1}-gew. SE, MTC in

  19. Preoperative localization and biopsy of non-palpable breast lesions with a special localization device on the Magnetom Open; Praeoperative Markierung und Biopsie nicht palpabler Mammalaesionen mit einer Zieleinrichtung am Magnetom Open

    Energy Technology Data Exchange (ETDEWEB)

    Sittek, H.; Linsmeier, E.; Perlet, C.; Schneider, P.; Baudrexel, C.; Reiser, M. [Klinikum Grosshadern, Muenchen (Germany). Inst. fuer Klinische Radiologie; Untch, M. [Klinikum Grosshadern, Muenchen (Germany). Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe

    2000-11-01

    Purpose. MRI-guided interventional maneuvers in the breast, when closed MRi scanners are employed are relatively complex and time consuming. The purpose of our investigations was to develop a special device for the localization and biopsy of breast lesions using an open low-field MRI Scanner (Magnetom Open, Siemens, Erlangen, Germany) permitting free access to the patient. Materials and methods. Due to its particular material and construction characteristics, a newly developed device for localization and biopsy of breast lesions is appropriate to remain within the magnetic field during the examination without degrading image quality. We performed 125 tests in a phantom and 31 investigations in patients including 26 wire-localizations and 5 biopsies. Results. The interventional maneuvers in the phantom could be performed very precisely. In all 125 phantom studies, the needle (14G coaxial biopsy cannula, Bard) was positioned close to the simulated lesion. In 25 out of 26 patients the needle was positioned within a distance less than 5 mm from the lesion. When using the 14G coaxial biopsy cannula (Bard, Karlsruhe, Germany) the needle tip was found adjacent next to the lesion in all 12 cases (7 wire-localizations, 5 biopsies). Conclusions. Our results indicate that our device allows very precise preoperative localization of breast lesions within the Magnetom Open. Using MRI-compatible, large-core needles, biopsy under direct MRI control resulted in good results. (orig.) [German] Zielsetzung. Am geschlossenen MRT-Geraet sind Interventionen an der Mamma relativ aufwendig und zeitintensiv. Ziel unserer Untersuchungen war es, eine Lokalisations- und Biopsieeinrichtung fuer das offene MRT-Geraet (Magnetom Open, Siemens) zu entwickeln und zu erproben. Patienten und Methode. Es wurde eine Lokalisations- und Biopsieeinrichtung entwickelt, die aufgrund ihrer Bauart waehrend der Intervention im Magnetfeld des MRT-Geraetes verbleiben kann und die Bildgebung nicht nachteilig

  20. ''Routine'' brain CT in psychiatric patients - does it make sense?; ''Routine''-Schaedel-CT in der psychiatrischen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Pickuth, D.; Heywang-Koebrunner, S.H.; Spielmann, R.P. [Martin-Luther-Universitaet Halle-Wittenberg, Halle (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie

    1999-11-01

    Purpose: To prospectively assess the spectrum of brain CT findings in psychiatric patients and to determine the number of patients that had an underlying cause for the symptoms. Patients and methods: Over a period of six months, 142 patients (78 males, 64 females; median age 61 [18-91] years) were referred for CT brain scans. Their scans were reviewed, along with the clinical information that was provided in the request form. All the hard copies were reviewed to assess areas of ischaemia, infarction, atrophy, tumours, and haematomas. The majority of requests were to exclude vascular event or space-occupying lesions. Clinical indications included mood disorders (depression, mania), schizophrenic disorders, dementia, personality and behavioural disorders. Results: 31 (22%) were normal. 111 (78%) had varying degrees of ischaemia, infarction and cerebral/cerebellar atrophy. 7 (4.9%) had space-occupying lesions which included two gliomas and five meningiomas. There were two chronic subdural haematomas and one arteriovenous malformation. Conclusion: 1. In our series, pathologic findings in 'routine' brain CT's were encountered in 78%. 2. The incidence of brain tumours was 4.9%, compared with 0.00005% of the general population. 3. CT scanning in psychiatric patients is cost-effective and especially indicated when there is an atypical presentation, or inadequate response to standard treatment. (orig.) [German] Hintergrund: Bei psychiatrischen Patienten wird vielerorts routinemaessig eine kraniale Computertomographie (CCT) durchgefuehrt. Ob der Nutzen die Kosten rechtfertigt, wurde im Rahmen einer Prospektivstudie untersucht. Patienten und Methode: In einem Zeitraum von 6 Monaten wurde bei 142 psychiatrischen Patienten (78 Maenner, 64 Frauen, 18-91 Jahre, Median 61 Jahre) ein CCT angefertigt. Die Untersuchung erfolgt nativ in 5-mm-Schichtdicke, bei klinischem Verdacht auf eine intrakraniale Raumforderung auch kontrastverstaerkt. Ueberweisungsdiagnosen waren v

  1. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  2. Interobserver variability of patient positioning using four different CT datasets for image registration in lung stereotactic body radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Oechsner, Markus [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Muenchen (Germany); Technical University of Munich, Zentrum fuer Stereotaxie und personalisierte Hochpraezisionsstrahlentherapie (StereotakTUM), Munich (Germany); Chizzali, Barbara; Devecka, Michal; Muench, Stefan [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Muenchen (Germany); Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Muenchen (Germany); Technical University of Munich, Zentrum fuer Stereotaxie und personalisierte Hochpraezisionsstrahlentherapie (StereotakTUM), Munich (Germany); Helmholtz Zentrum Muenchen, Institute of Innovative Radiotherapy (iRT), Munich (Germany)

    2017-10-15

    mit Lungenlaesionen wurde eine manuelle Bildregistrierung mit FB-CBCT von vier Observern durchgefuehrt. Ein langsames Planungs-CT (PCT), eine mittlere Intensitaetsprojektion (AIP), eine maximale Intensitaetsprojektion (MIP) und ein ''mid-ventilation''-CT (MidV) wurden als Referenz-CT verwendet. Ausgewertet wurden Verschiebedifferenzen zwischen den vier Referenz-CT-Datensaetzen fuer jeden Observer sowie Differenzen zwischen den Observern fuer das gleiche Referenz-CT. Statistische Analysen wurden durchgefuehrt und Korrelationen zwischen Verschiebedifferenzen und 3D-Tumorbewegung oder CBCT-Bewertung berechnet. Die mittlere 3D-Verschiebedifferenz zwischen Referenz-CT-Datensaetzen war fuer AIPvsMIP (Spanne 1,1-2,2 mm) am geringsten und fuer MidVvsPCT (Spanne 2,8-3,5 mm) am groessten, mit Differenzen >10 mm. Die 3D-Verschiebungen zeigten zum Teil signifikante Korrelationen zur 3D-Tumorbewegung und CBCT-Bewertung. Der Interobserververgleich fuer gleiche Referenz-CT-Datensaetze ergab die kleinsten mittleren ∇3D-Differenzen und mittlere ∇3D-Standardabweichungen fuer ∇AIP (1,5 ± 0,7 mm; 0,7 ± 0,4 mm). Die maximale 3D-Verschiebedifferenz zwischen den Observern betrug 10,4 mm (∇MidV). 3D-Tumorbewegung und mittlere CBCT-Bewertung korrelierten mit den Verschiebedifferenzen (R{sub s} = 0,336-0,740). Das verwendete Referenz-CT beeinflusst die Bildregistrierung und bedingt Interobserver-Variabilitaeten. 3D-Tumorbewegung und CBCT-Bildqualitaet beeinflussen die Verschiebedifferenzen. Da fuer AIP die kleinsten Unterschiede berechnet wurden, scheint es fuer die Bildregistrierung mit FB-CBCT am besten geeignet. (orig.)

  3. Magnetic resonance imaging of respiratory movement and lung function; Magnetresonanztomographie der Atembewegung und Lungenfunktion

    Energy Technology Data Exchange (ETDEWEB)

    Tetzlaff, R. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie (E010), Heidelberg (Germany); Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische und Biologische Informatik, Heidelberg (Germany); Eichinger, M. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie (E010), Heidelberg (Germany)

    2009-08-15

    Lung function measurements are the domain of spirometry or plethysmography. These methods have proven their value in clinical practice, nevertheless, being global measurements the functional indices only describe the sum of all functional units of the lung. Impairment of only a single component of the respiratory pump or of a small part of lung parenchyma can be compensated by unaffected lung tissue. Dynamic imaging can help to detect such local changes and lead to earlier adapted therapy. Magnetic resonance imaging (MRI) seems to be perfect for this application as it is not hampered by image distortion as is projection radiography and it does not expose the patient to potentially harmful radiation like computed tomography. Unfortunately, lung parenchyma is not easy to image using MRI due to its low signal intensity. For this reason first applications of MRI in lung function measurements concentrated on the movement of the thoracic wall and the diaphragm. Recent technical advances in MRI however might allow measurements of regional dynamics of the lungs. (orig.) [German] Die Lungenfunktion wird bislang hauptsaechlich durch die Spirometrie oder Plethysmographie untersucht. Diese Methoden sind zwar sehr leistungsfaehig zur Diagnostik von Lungenerkrankungen, sind jedoch globale Messmethoden, deren Messparameter immer die Summe aller funktionellen Einheiten der Lunge beschreiben. Veraenderungen, die auf eine Teilkomponente der Atempumpe beschraenkt sind oder kleine Teile des Lungengewebes betreffen, koennen durch gesunde Lungenanteile kompensiert werden. Mit dynamischen bildgebenden Verfahren koennten solche regionalen Veraenderungen erfasst und so eine fruehere Therapie ermoeglicht werden. Die Magnetresonanztomographie (MRT) bietet sich hier ideal an, da sie als Schnittbildverfahren weder die Probleme der Bildverzerrung, der Projektionsverfahren noch die Strahlenbelastung der Computertomographie hat. Allerdings wird die MRT der Lunge durch das geringe Signal des

  4. Functional MRT in psychiatry and neurology

    International Nuclear Information System (INIS)

    Schneider, F.; Fink, G.R.

    2007-01-01

    Almost no other method has reach such an interest as the functional imaging in psychiatric and neurological science; it is fascinating to observe the brain at work. The fundamentals of functional magnetic resonance tomography (fMRT) and the interpretation of MRT images are explained; the state-of-the-art is discussed. The book is focussed on the functional imaging within psychiatry and neurology. The book contains 45 contributions within the following chapters: fundamentals, higher brain accomplishments, disease pattern, examinatory examples, perspectives

  5. Rheumatoid arthritis of the wrist; Dynamic Gd-DTPA enhanced MRT. Rheumatoide Arthritis des Handgelenkes; Dynamische Gd-DTPA-verstaerkte MRT

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. (Radiologische Universitaetsklinik, Bonn (Germany)); Kunze, V. (Radiologische Universitaetsklinik, Bonn (Germany)); Koch, W. (Orthopaedische Universitaetsklinik, Bonn (Germany)); Bruening, R. (Radiologische Universitaetsklinik, Bonn (Germany)); Seelos, K. (Radiologische Universitaetsklinik, Bonn (Germany)); Stroehmann, I. (Radiologische Universitaetsklinik, Bonn (Germany)); Woell, B. (Radiologische Universitaetsklinik, Bonn (Germany)); Reiser, M. (Radiologische Universitaetsklinik, Bonn (Germany))

    1993-02-01

    21 patients with rheumatoid arthritis of the wrist diagnosed according to the criteria of the American Rheumatism Association were examined by dynamic MRT before and after the i.v. injection of Gd-DTPA (0.1 mmol/kg). The results were correlated with the clinical and radiological findings. The increased signal intensity of the pannus was 1.17[+-]0.45%/sec and this differed significantly (p<0.001) from bone marrow (0.16[+-]0.11%/sec) and from muscle (0.25[+-]0.16%/sec). Blood sedimentation rate correlated with the gradient of synovial proliferation (p<0.05). There were no further statistically significant correlations between the clinical, radiological and MRT findings and the change in signal intensity from synovial proliferation as shown by dynamic MRT. (orig.)

  6. The value of magnetic resonance imaging (MRI) in the treatment planning of vertebral metastasis considering economic aspects. A cost benefit-analysis; Die Wertigkeit der Magnetresonanztomographie (MRT) unter oekonomischen Aspekten bei der Bestrahlungsplanung von Wirbelkoerpermetastasen. Eine Kosten-Nutzen-Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Prott, F.J.; Schlehuber, E.; Scharding, B.J.; Rinast, E. [Strahlentherapie Wiesbaden, St.-Josefs-Hospital (Germany); Micke, O. [Klinik und Poliklinik fuer Strahlentherapie - Radioonkologie, Universitaetsklinikum Muenster (Germany)

    2002-05-01

    Is magnetic resonance imaging (MRI) based target volume definition for treatment planning of vertebral metastasis effective under economic considerations.From 1994 to 1999, a total of 137 patients with bone metastases affecting the vertebral column underwent MRI of the cercival, thoracic, or lumbar spine for the treatment planning of palliative radiation therapy. The following radiation treatment consisted in a irradiation of the affected vertebral region up to a total dose of 30-40 Gy.The cost calculation for radiotherapy and magnetic resonance tomography was done using the common tariff model (EBM) of the German Health Insurances.In 73% of patients (101 patients), magnetic resonance imaging resulted in marked corrections of the irradiation fields which would have resulted in the necessity of treatment for recurrence in the case of treatment planning without MRI.Consequently, the higher cost of MRI of 345.00 DEM (176,40 EUR) lead to a saving of 497.00 DEM (254,11 EUR) compared to a recurrence treatment of 10 fractions and of 1,428.00 DEM (730,12 EUR) compared to 20 fractions. The transport expenses for the second treatment could be saved as well.Even under economic considerations MRI is effective. (orig.) [German] Ist eine MRT-gestuetzte Zielvolumendefinition bei der Strahlentherapie von Knochenmetastasen ein sinnvolles Vorgehen unter oekonomischen Gesichtspunkten?1994-1999 wurde bei 137 Patienten mit einem ossaer metastasierenden Tumor und Befall der Wirbelsaeule eine Magnetresonanztomographie (MRT) zur Planung einer palliativen Radiatio durchgefuehrt. Die nachfolgende Strahlentherapie bestand aus einer Radiatio des betroffenen Wirbelkoerperabschnitts bis zu einer Gesamtherddosis von 30-40 Gy. Fuer die Berechnung der Kosten wurde der einheitliche Bewertungsmassstab der Deutschen Krankenkassen zugrunde gelegt.Aufgrund der MRT-Untersuchungen wurde bei 73% der Patienten eine Veraenderung des Bestrahlungsfeldes vorgenommen, die im Falle einer nicht MRT

  7. Locoregional recurrence of rectal carcinoma. A CT-analysis and a target volume concept in adjuvant radiotherapy; Das lokoregionaere Rezidiv des Rektumkarzinoms. Eine computertomographische Analyse und ein Zielvolumenkonzept fuer die adjuvante Radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Bagatzounis, A. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Koelbl, O. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Mueller, G. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Oppitz, U. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Willner, J. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie; Flentje, M. [Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Strahlentherapie

    1997-02-01

    Patients and method: 155 patients with the diagnosis of rectal carcinoma recurrences were treated in our institution between 1980 and 1995. To determine the extension of the recurrent tumor within the pelvic levels (praesacral levels S1-S5, precoccygeal-, pelvic floor level and perineal level) and the tumor infiltration of pelvic organs and muscles we analysed the pretherapeutic CT-images. The lymphnode recurrences were classified as: Pararectal-, presacral-, iliac internal-, iliac external-, iliac communis- and paraaortal recurrences. Results: Sixty-one percent of the patients with rectum exstirpation and 66% with anterior resection showed a combined local and nodal recurrence. Isolated lymph node recurrences were rare (4% and 5%). The local recurrence was mostly situated in the presacral pelvis, predominantly there was an infiltration of the presacral space at the level of S4, S5 and os coccygis regardless of the operating method and the primary tumor location. The anastomosis was involved in the tumor recurrence in 93% of the anteriorly resected patients. In 9 out of 96 patients after rectum exstirpation the pelvic region caudal of the tip of the coccyx was the origin of the recurrent tumor. Primarily all 9 patients had a deep-seated carcinoma (<6 cm ab ano). Only 2 patients showed an isolated perineal recurrence after rectum exstirpation. Two thirds of the deepseated tumors showed a vaginal involvement. The incidence of iliac internal- and presacral nodal recurrence was 47 to 59%. The incidence of iliac external lymph node recurrences was 7% after rectum exstirpation and 2% after anterior resection/Hartmann procedure. (orig./AJ) [Deutsch] Patienten und Methode: 155 Patienten wurden in unserer Klinik im Zeitraum 1980 bis 1995 wegen eines Rektumkarzinomrezidivs behandelt. Die Rezidivausdehnung innerhalb der Beckenetagen (Sakralsegmente S1 bis S5, praekokzygeal, Beckenbodenetage und perineales Weichgewebe) und die Infiltration von Beckenorganen und Muskelgruppen

  8. Anatomy of the fingers in MR imaging using a high resolution surface coil; Die Anatomie der Finger in der MRT unter Anwendung einer Hochaufloesungsspule

    Energy Technology Data Exchange (ETDEWEB)

    Maeurer, J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Mueller, H.F. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Lemke, A.J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Requardt, R. [Siemens AG, Erlangen (Germany); Stein, I. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Langer, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)

    1994-12-31

    MR-images of the fingers of twenty healthy volunteers were obtained at a 1,5-T whole-body system with a high resolution coil. Additionally, the fingers of two formalin-fixed anatomical specismen were imaged, fronzen and then subsequently sectioned for anatomic correlation. Measurements were recorded with a slice thickness of 2 mm. A 256x256 matrix and a 2,5 cam fiel of view (FOV) were used resulting in a pixel size of 0,01 mm{sup 2}. Based on the excellent depiction of anatomic detail and contrast resolution high resolution MRI of the fingers enabled identification of osseous and cartilaginous structures, as well as delineation of tendons, ligaments blood-vessels and dermal layers. (orig.) [Deutsch] An einem 1,5-T-Ganzkoerpertomographen wurden die Finger von 20 gesunden Probanden mit einer Hochaufloesungsspule zur Darstellung der Anatomie untersucht. Zum Vergleich erfolgte die Abbildung der anatomischen Strukturen an zwei formol- und alkoholfixierten Leichepraeparaten der Hand mittels MRT. Im Anschluss wurden die untersuchten Regionen am tiefgefrorenen Praeparat mit einer Bandsaege nachgeschnitten. Die MR-Messungen wurden mit einer Schichtdicke von 3 mm, einem Field of View (FOV) von 25 mm und einer Matrix von 256x256 Pixel durchgefuehrt. Die daraus resultierende Pixelgroesse betrug 0,01 mm{sup 2}. Der Weichteilkontrast und die hohe Ortsaufloesung ermoeglichten die Identifikation von Knochen- und Knorpelstrukturen sowie die Abgrenzung von Sehnen, Baendern, Blutgefaessen und Hautschichten. (orig.)

  9. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai; Ma, Rui; Wang, Li Jun [Dept. of Radiology, Baotou Central Hospital, Baotou (China); Li, Li Gang; Chen, Jiu Hong [CT BM Clinic Marketing, Siemens Healthcare, Beijing (China)

    2012-11-15

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 {+-} 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 {+-} 0.306 [group A] vs. 1.084 {+-} 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 {+-} 0.16 mSv in group A and 7.1 {+-} 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  10. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    International Nuclear Information System (INIS)

    Sun, Kai; Ma, Rui; Wang, Li Jun; Li, Li Gang; Chen, Jiu Hong

    2012-01-01

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  11. Gaucher disease: MR evaluation of bone marrow features during treatment with enzyme replacement; Morbus Gaucher: Analyse der Knochenmarkveraenderungen in der MRT waehrend Enzymersatztherapie

    Energy Technology Data Exchange (ETDEWEB)

    Poll, L.W.; Koch, J.A.; Boerner, D.; Cohnen, M.; Jung, G.; Scherer, A.; Moedder, U. [Duesseldorf Univ. (DF). Inst. fuer Diagnostische Radiologie; Dahl, S. vom; Haeussinger, D. [Duesseldorf Univ. (Germany). Klinik fuer Gastroenterologie, Hepatologie und Infektiologie; Willers, R. [Rechenzentrum, Heinrich-Heine-Univ. Duesseldorf (Germany); Niederau, C. [Innere Abt., St. Josef-Hospital Oberhausen, Akademisches Lehrkrankenhaus der Univ. Essen (Germany)

    2001-10-01

    Purpose: Enzyme replacement therapy (ERT) arrests and reverses the hematological and visceral symptoms of adult Gaucher disease, the most frequent lysosomal storage disorder. There are only a few studies available evaluating bone disease during ERT. The aim of this study was to investigate the features of bone marrow (bm) by magnetic resonance imaging (MRI) in these patients during ERT. Materials and Methods: MRI was performed prospectively in thirty adult type I Gaucher patients before and during ERT with a mean follow-up of 3 years. Spin-echo sequences (T{sub 1}/T{sub 2}) of the lower extremities were obtained and the reconversion (response) or lack of reconversion (non-response) to fatty marrow during treatment was analyzed. The morphological features of bm involvement, a homogeneous or non-homogeneous distribution of bm changes and focal bone lesions surrounded by a rim of reduced signal intensity (SI), were analyzed. Results: Infiltration of bm by Gaucher cells is characterized by a reduction of Sl on both T{sub 1}- and T{sub 2}-weighted sequences. Bone marrow responses were seen in 19 patients (63%) during treatment. Focal bone lesions, surrounded by a rim of reduced Sl, did not respond to ERT and correlated with a non-homogenous distribution of bone involvement and splenectomy. (orig.) [German] Ziel: Unter Enzymersatztherapie (enzyme replacement therapy = ERT) zeigen Patienten mit adulter Form des Morbus Gaucher, der haeufigsten lysosomalen Speicherkrankheit, eine deutliche Besserung der haematologischen und visceralen Symptome. Bislang liegen nur wenige Untersuchungen zur Analyse der Knochenveraenderungen waehrend der ERT vor. Ziel war es, die Knochenmarkveraenderungen bei Gaucher-Patienten waehrend der Enzymersatztherapie mit Alglucerase/Imiglucerase in der Magnetresonanztomographie (MRT) zu evaluieren. Material und Methoden: In einer prospektiven Untersuchung wurden 30 adulte Patienten mit gesichertem Morbus Gaucher vor und waehrend der ERT in der MRT

  12. MRI morphologic alterations after liver SBRT. Direct dose correlation with intermodal matching

    Energy Technology Data Exchange (ETDEWEB)

    Boda-Heggemann, Judit; Jahnke, Anika; Jahnke, Lennart; Vogel, Lena; Simeonova-Chergou, Anna O.; Herskind, Carsten; Wenz, Frederik; Lohr, Frank [University of Heidelberg, Department of Radiation Oncology, University Medical Center Mannheim, Mannheim (Germany); Attenberger, Ulrike; Budjan, Johannes [University of Heidelberg, Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim (Germany)

    2016-09-15

    CT morphologic and histopathologic alterations have been reported after SBRT. We analyzed the correlation of MRI morphologic alterations with radiation doses to assess the potential for MRI-based dose-effect correlation in healthy liver tissue. MRI data of 24 patients with liver metastases 7±3 weeks after image-guided SBRT in deep-inspiration breath-hold were retrospectively analyzed. MRI images were intermodally matched to the planning CT and corresponding dose distribution. Absolute doses were converted to EQD{sub 2,α/β=x} with α/β values of 2, 3 for healthy liver tissue, 8 Gy for modelled predamaged liver tissue and 10 Gy for tumor tissue. A central nonenhancing area was observed within the isodose lines of nominally 48.2 ± 15.2 Gy, EQD{sub 2Gy/α/β=10} 92.5 ± 27.7 Gy. Contrast-enhancement around the central nonenhancing area was observed within the isodose lines of nominally 46.9 ± 15.3 Gy, EQD{sub 2Gy/α/β=10} 90.5 ± 28.3 Gy. Outside the high-dose volume, in the beam path, characteristic sharply defined, nonblurred MRI morphologic alterations were observed that corresponded with the following isodose lines: T1-intensity changes occurred at isodose lines of nominally 21.9 ± 6.7 Gy (EQD{sub 2,α/β=2} 42.5 ± 8.7 Gy, EQD{sub 2,α/β=3} 38.5 ± 7.6 Gy, EQD{sub 2,α/β=8} 30.2 ±6.3 Gy). T2-hyper/hypointensity was observed within isodose lines of nominally 22.4 ± 6.6 Gy (EQD{sub 2,α/β=2} 42.7 ± 8.1 Gy, EQD{sub 2,α/β=3} 38.7 ± 7 Gy; EQD{sub 2,α/β=8} 30.5 ± 5.9 Gy). Using deformable matching, direct spatial/dosimetric correlation of SBRT-induced changes in liver tissue was possible. In the PTV high-dose region, a central nonenhancing area and peripheral contrast medium accumulation was observed. Beam path doses of 38-42 Gy (EQD{sub 2,α/β=2-3}) induce characteristic MRI morphologic alterations. (orig.) [German] CT-morphologische Veraenderungen nach SBRT sind beschrieben und korrelieren mit histopathologischen Veraenderungen. Ziel war es, MRT

  13. Recognize and classify pneumoconiosis; Pneumokoniosen erkennen und klassifizieren

    Energy Technology Data Exchange (ETDEWEB)

    Hering, K.G.; Hofmann-Preiss, K. [Klinikum Westfalen, Knappschaftskrankenhaus, Dortmund (Germany)

    2014-12-15

    In the year 2012, out of the 10 most frequently recognized occupational diseases 6 were forms of pneumoconiosis. With respect to healthcare and economic aspects, silicosis and asbestos-associated diseases are of foremost importance. The latter are to be found everywhere and are not restricted to large industrial areas. Radiology has a central role in the diagnosis and evaluation of occupational lung disorders. In cases of known exposure mainly to asbestos and quartz, the diagnosis of pneumoconiosis, with few exceptions will be established primarily by the radiological findings. As these disorders are asymptomatic for a long time they are quite often detected as incidental findings in examinations for other reasons. Therefore, radiologists have to be familiar with the pattern of findings of the most frequent forms of pneumoconiosis and the differential diagnoses. For reasons of equal treatment of the insured a quality-based, standardized performance, documentation and evaluation of radiological examinations is required in preventive procedures and evaluations. Above all, a standardized low-dose protocol has to be used in computed tomography (CT) examinations, although individualized concerning the dose, in order to keep radiation exposure as low as possible for the patient. The International Labour Office (ILO) classification for the coding of chest X-rays and the international classification of occupational and environmental respiratory diseases (ICOERD) classification used since 2004 for CT examinations meet the requirements of the insured and the occupational insurance associations as a means of reproducible and comparable data for decision-making. (orig.) [German] Im Jahr 2012 waren 6 der 10 am haeufigsten anerkannten Berufskrankheiten Pneumokoniosen. Gesundheitspolitisch und oekonomisch stehen dabei die Silikose und asbestassoziierte Erkrankungen im Vordergrund. Insbesondere Letztere treten ubiquitaer auf und sind nicht an grosse Industriestandorte gebunden

  14. Thin-section spiral CT evaluation of morphologic effects of aging lung in asymptomatic adult subjects

    International Nuclear Information System (INIS)

    Li Kuncheng; Liu Jian; Yang Yanhui; Yao Xinyu; Yin Jianguo; Wang Shiwen; He Zuoxiang

    2006-01-01

    Objective: To evaluate the imaging signs of aging lung in asymptomatic adult subjects by using thin-section spiral CT, and analyze the correlation between the signs and the age of examined cases, as well as probe their clinical application value. Methods: One hundred and six healthy adult subjects were divided into 3 groups: 30 to 44 years (n=31), 45 to 59 years (n=30), and over 60 years (n=45), and all the subjects underwent thin-section spiral CT scans in the upper lung field, the middle lung field and the lower lung field. The evaluation indices included the lung interstitium changes, emphysematous changes, mosaic perfusion, dependent density difference, and pleural thickenning. According to the relative score standard, the above-mentioned indices were totally calculated and converted into the score value. The data were statistically processed with SPSS for Windows. Results: Among the three groups, there were remarkable differences in the indices including the lung interstitium changes, emphysematous changes, and mosaic perfusion, respectively (χ 2 =8.10, 9.73, 15.54, P 2 =3.66, 3.24, P> 0.05). The score values had a significant positive correlation with the age (r=0.709, P<0.01). Conclusion: The signs including the lung interstitium changes, emphysematous changes, mosaic perfusion, the dependent density difference, and pleural thickenning can be found in asymptomatic subjects, and they become prominent as the age increases. HRCT is one of the most important methods for evaluating the early signs of the senile lung. (authors)

  15. Systematics of injuries of the rotator cuff and biceps tendon; Systematik der Verletzungen von Rotatorenmanschette und Bizepssehne

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Landesklinikum Horn, Institut fuer Radiologie und interventionelle Radiologie, Horn (Austria); Pones, M.; Breitenseher, J.B. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria)

    2015-03-01

    Injuries of the rotator cuff and the biceps tendon demonstrate different patterns, which can be recognized clinically and radiologically. These patterns are impingement syndrome with additional trauma, isolated trauma of the rotator cuff and shoulder dislocation causing rotator cuff tears. Furthermore, it is clinically crucial to evaluate the extent of a rotator cuff injury. Magnetic resonance imaging (MRI) is the modality of choice to differentiate these patterns. (orig.) [German] Bei der Verletzung von Rotatorenmanschette und Bizepssehne koennen verschiedene Muster klinisch und radiologisch erkannt werden. Diese Muster sind das Impingementsyndrom mit einem zusaetzlichen Trauma, das isolierte Trauma und die Verletzung der Rotatorenmanschette im Rahmen einer Schulterluxation. Darueber hinaus ist die Beurteilung des Ausmasses einer Verletzung von zentraler klinischer Relevanz. Die MRT kann die Differenzierung dieser Muster bestmoeglich durchfuehren. (orig.)

  16. Application of triple rule-out with 64-slice spiral CT in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Li Pengyu; Li Kuncheng; Du Xiangyin; Cao Lizhen; Liu Jiabin; Yang Yanhuui; Liang Zhigang; Zhu Xiaolian; Liu Jian

    2007-01-01

    Objective: To investigate the performance of triple rule-out with 64-slice spiral CT in the combined examination of pulmonary artery, thoracic aorta and coronary artery for patients with acute chest pain. Methods: Seventy patients who presented with acute chest pain were included in the study. All of the patients underwent retrospective ECG-gated 64-slice computed tomography triple rule-out examination to evaluate the pulmonary arteries, thoracic aorta and coronary arteries. Multi-planar reconstruction (MPR), maximum intensity projection (MIP), curved-planar reconstruction (CPR) and volume rendering (VR) were used to display pulmonary arteries, thoracic aorta and coronary arteries. We evaluated the image quality of coronary artery and the enhancement of the pulmonary artery and thoracic aorta to estimate if the examination can fulfill the clinical demand for the differential diagnosis of acute chest pain. Results: The mean scan time was (8.5±1.0) s, and the dose of contrast medium injected was 100 ml. There were 95.7% (67/70) of patients whose CT values detected in the pulmonary artery and thoracic aorta after enhancement Were ≥200 HU. The image quality of 85.8% (720/839) coronary segments was classified as excellent, 8.6% (72/839) as good, and 5.6% (47/839) as poor. There were 20 eases with coronary stenoses ≥50%, 2 cases with pulmonary embolism, and 2 cases with aortic dissection. Conclusion: The triple rule-out examination with 64-slice spiral CT could depict pulmonary artery, thoracic aorta, and coronary artery in 8 s with good image quality. It has great potential in the etiological diagnosis for the patients with acute chest pain. (authors)

  17. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  18. Evaluation of multiple trauma victims with 16-row multidetector CT (MDCT): a time analysis; Anwendung der 16-Zeilen-Mehrdetektor-CT in der Initialdiagnostik beim Polytrauma: Eine Zeitanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, C.M.; Nicolas, V. [Bochum Univ. (Germany). Inst. fuer Diagnostische Radiologie, Interventionelle Radiologie und Nuklearmedizin; Rduch, G.J. [Bochum Univ. (Germany). Klinik fuer Chirurgie; Wick, M.; Muhr, G. [Bochum Univ. (Germany). Medizinische Klinik III, Pneumologie, Allergologie und Schlafmedizin; Bauer, T.T. [Berufsgenossenschaftliche Kliniken Bergmannsheil, Ruhr-Univ. Bochum (Germany)

    2005-12-15

    Purpose: Description and time analysis of a 16-row MDCT protocol in the evaluation of multiple trauma patients considering transport, time of scanning, patient positioning, image reconstruction, and image interpretation. Materials and methods: Between May and December 2004, 60 multiple trauma patients underwent 16-row MDCT (Sensation, Siemens, Erlangen, Germany). The protocol included serial scanning of the head, spiral scanning of the cervical spine and contrast-enhanced spiral scanning of the thorax/abdomen with multiplanar reformations (MPR) of the thoracic/lumbar spine and the pelvis. All time intervals including transport, patient positioning, scanning, duration of MPR, total time in the examination room, and time to first and final image interpretation were prospectively evaluated. Furthermore, patient characteristics, trauma profiles, and mortality rates were recorded. Results: 46 male and 14 female patients (mean age 43.6 years) were enrolled in the study. Time analysis of 16-row MDCT revealed the following results (mean time standard deviation): Emergency room treatment and transport 19.2{+-}6.7 min, patient positioning 16.5{+-}6.5 min, scan duration 8.0{+-}3.3 min, total time in examination room 24.5{+-}7.2 min, image reconstruction including MPR 32.0{+-}16.4 min, and time of first (16.4{+-}4.7 min) and final image interpretation (82.5{+-}30.4 min). Trauma profiles revealed thoracic injuries in 35/60 patients (58.3%), head injuries in 23/60 patients (38.3%), abdominal injuries in 15/60 patients (25.0%), injuries of the cervical (9/60 patients, 15.0%), thoracic (12/60 patients, 20.0%), and lumbar spine (19/60 patients, 31.7%), pelvic injuries in 13/60 patients (21.7%), and injuries of extremities in 39/60 patients (65.0%). The mortality rate was 21.7%. (orig.)

  19. Percutaneous CT-guided treatment of osteoidosteomas: combination of drill biopsy and subsequent ethanol injection; Perkutane CT-gesteuerte Behandlung von Osteoidosteomen: kombiniertes Vorgehen mit einem Hohlbohrer und nachfolgender Aethanolinjektion

    Energy Technology Data Exchange (ETDEWEB)

    Adam, G. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Keulers, P. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Vorwerk, D. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Heller, K.D. [Orthopaedische Klinik, RWTH Aachen (Germany); Fuezesi, L. [Inst. fuer Pathologie, RWTH Aachen (Germany); Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany)

    1995-03-01

    The purpose of this study was the clinical evaluation of a percutaneous treatment modality in patients with an osteoidosteoma. 6 patients with an osteoidosteoma of the upper (n=1) and lower (n=5) extremity which were confirmed on plain film radiographs and computed tomography underwent CT controlled drill biopsy of the nidus with subsequent injection of 96% ethanol into the biopsy channel to sclerose probably remaining remnants of the nidus. The procedure was started under local anaesthesia, but drilling of the nidus was carried out under a short general anaesthesia using ketamine. The intervention was successful in all patients. No postinterventional infection occurred and no recurrence was observed in any of the patients in a follow-up time between 0.5 and 2 years. (orig./MG) [Deutsch] Zielsetzung der Untersuchungen war die klinische Erprobung eines perkutanen Verfahrens zur Behandlung von Osteoidosteomen. Bei 6 Patienten mit einem nativradiologisch und computertomographisch nachgewiesenen Osteoidosteom im Bereich der oberen (n=1) und der unteren Extremitaet (n=5) wurde perkutan unter CT-Kontrolle der Nidus ausgebohrt und ueber den Bohrkanal 96%iger Alkohol nachinjiziert, um etwaige Nidusreste zu sklerosieren. Der Eingriff wurde in Lokalanaesthesie begonnen, die Ausbohrung des Nidus unter einer Ketanestkurznarkose durchgefuehrt. Das Vorgehen war bei allen Patienten erfolgreich. In keinem Fall wurde eine postinterventionelle Infektion beobachtet. Ueber den Nachbeobachtungszeitraum von 0,5 bis zu 2,5 Jahren trat bei keinem der Patienten ein Rezidiv auf. (orig./MG)

  20. Preclinical imaging in animal models of radiation therapy; Praeklinische Bildgebung im Tiermodell bei Strahlentherapie

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaou, K.; Cyran, C.C.; Reiser, M.F.; Clevert, D.-A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Lauber, K. [Klinikum der Ludwig-Maximilians-Universitaet, Klinik und Poliklinik fuer Strahlentherapie, Muenchen (Germany)

    2012-03-15

    -funktionelle Informationen ueber den Tumor zur Verfuegung gestellt werden. Die dynamische kontrastmittelverstaerkte MRT-, CT- oder ultraschallbasierte Perfusionsbildgebung sowie Hybridverfahren wie PET/CT oder MRT/PET haben das Potenzial, vitale und/oder perfundierte Tumoranteile zu identifizieren und abzugrenzen, um so eine gezielte Strahlentherapie zu optimieren. Ziel ist eine genauere Abgrenzung und Behandlung des Tumors bei gleichzeitiger Reduzierung der Dosis und Schonung des umliegenden gesunden Gewebes. In der Entwicklung neuer bildgebender Methoden fuer die Planung einer individualisierten Strahlentherapie kommt der praeklinischen, wissenschaftlichen Bildgebung und Forschung eine besondere Rolle zu, da nur in einem praeklinischen Setting, also in tierexperimentellen Tumormodellen, die Moeglichkeiten einer multimodalen Bildgebung ausreichend genau evaluiert und weiterentwickelt werden koennen. Neue funktionelle bildgebende Methoden werden fuer die Ueberwachung einer fruehen Therapieantwort (''early response'') unter Strahlentherapie oder fuer die Darstellung der Wertigkeit neuer Kombinationstherapien (z. B. Antiangiogenese plus Strahlentherapie) eine zunehmende Rolle spielen. (orig.)

  1. Use of spiral computed tomography volumetry for determining the operative approach in patients with Graves' disease.

    Science.gov (United States)

    Choi, June Young; Lee, Kyu Eun; Koo, Do Hoon; Kim, Kyu Hyung; Kim, Eun young; Bae, Dong Sik; Jung, Sung Eun; Youn, Yeo-Kyu

    2014-03-01

    The purposes of the present study were to assess (1) the correlation between the weight of the postoperative thyroid specimen and the spiral computed tomography (CT) volumetry results of the thyroid gland in patients with Graves' disease, and (2) the utility of CT volumetry for determining the operative approach. From 2009 to 2010, a total of 56 patients with Graves' disease underwent total or subtotal thyroidectomy. An enhanced spiral CT was taken in all patients prior to the operation. From 2.5 mm-thick slices of the thyroid gland, the surface area was calculated to measure the volume of the thyroid gland. The glandular volume was compared to the weight of the postoperative thyroid specimen. A total of 42 and 14 patients underwent total and subtotal thyroidectomy, respectively. The mean weight of the postoperative thyroid specimen was 43.9 ± 33.4 g, and the mean volume obtained by CT volumetry was 44.2 ± 32.8 mL. A good correlation was observed between the weight of the postoperative thyroid specimen and the volume calculated by CT (r = 0.98, p 100 mL and the ≤100 mL groups (608.3 ± 540.8 vs. 119.7 ± 110.4 mL; p = 0.036). Spiral CT volumetry may be used to measure the thyroid volume reliably in patients with Graves' disease. For cases in which surgery is indicated in patients with Graves' disease, CT volumetry provides useful information from which to determine the operative approach. One hundred milliliter or less of thyroid volume in CT volumetry is recommended to perform minimally invasive thyroid surgery.

  2. Effect of imaging parameters of spiral CT scanning on image quality for the dental implants. Visual evaluation using a semi-anthropomorphic mandible phantom

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indou, Hiroko; Honda Eiichi

    2002-01-01

    The purpose of this study was to evaluate the effect of parameters of spiral CT scanning on the image quality required for the planning of dental implants operations. A semi-anthropomorphic mandible phantom which has artificial mandibular canals and teeth roots was used as a standard object for imaging. Spiral CT scans for the phantom settled in water phantom with diameters of 20 and 16 cm were performed. Visibility of the artificial mandibular canal made of a Teflon tube and gaps between tooth apex and canal in the mandibular phantom was evaluated for various combinations of the slice thickness, tables speeds, angles to the canal, and x-ray tube currents. Teeth roots were made of PVC (poly vinyl chloride). The artificial mandibular canal was clearly observed on the images of 1 mm slice thickness. At the same table speed of 2 mm /rotation, the images of thin slice (1 mm) were superior to that of thick slice (2 mm). The gap between teeth apex and canal was erroneously diagnosed on the images with table speeds of 3 mm/rotation. Horizontal scanning in parallel to the canal result in poor image quality for observation of mandibular canals because of the partial volume effect. A relatively high x-ray tube current (125 mA) at thin slice (1 mm) scanning was required for scanning the mandibular phantom in 20 cm water vessel. Spiral scanning with slice thickness of 1 mm and table speeds of 1 of 2 mm/rotation seemed to be suitable for dental implants. The result of this study suggested that diagnosis from two independent spiral scans with a different angle to the object was more accurate and more efficient than single spiral scanning. (author)

  3. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  4. Dose assessment of head CT examination by volume scanning with 320-area-detector

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Kobayashi, Masanao

    2009-01-01

    CT with the 320-area-detector (320-ADCT), first presented in 2007, still requires further basic studies, particularly in the field of dose assessment, as the CT has been widely spread in clinic due to its many advantages compared with the usual spiral CT. In this paper, the assessment in the title was thereby done in human phantom and a patient with suspicious acute cerebral infarction under different scanning modes (non-spiral, spiral and volume) for their comparison. Machines for 320-ADCT, and non-spiral and spiral CT were Toshiba Aquilion ONE, and Aquilion 64-MD, respectively. Scanning of the phantom and patient was individually conducted under similar conditions of tube voltage/ current, rotation time and length with the same field of view with defined nominal slice thicknesses. Alderson human body phantom in which 240 thermoluminescent dosimeters were indwelled, was used; doses were read by the thermoluminescence dosimeter (TLD) reader model 3000 (Kyokko Co.) after scanning; and effective doses were calculated with reference to ICRP publ. 102/103 equations for patient's head to be 4.2 (64-MDCT) and 6.6 (320-ADCT) mSv, which were respectively 6.4 and 5.4 mSv when estimated using the conversion coefficient and DLP (dose length product) in the texts. It was suggested that the exposure dose at the volume scanning by 320-ADCT can be reduced in the routine examination, and in the exact diagnosis, possibly increases. These doses can be reduced further by optimization of scanning conditions by additional basic investigations. (K.T.)

  5. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  6. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  7. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    wiederholte Untersuchungen durchlaufen muessen, und paediatrische Patienten relevant ist. Dabei koennen jedoch die Erfahrungen, die im Verlauf der letzten Jahre mit der Hybridtechnologie PET-CT gewonnen wurden, nicht direkt auf die MR-PET uebertragen werden. Ein wesentliches Beispiel hierfuer ist die Schwaechungskorrektur, fuer die in der PET-CT die mittels CT bestimmten Hounsfield-Einheiten verwendet werden. Da die in der PET emittierten 511-keV-Photonen durch das Koerpergewebe des Patienten geschwaecht werden, werden die CT-Datensaetze in sog. lineare Schwaechungskoeffizienten (''linear attenuation coefficients'', LAC) konvertiert. Da die Bilddatenakquisition in der MRT nicht auf einer Schwaechung von Roentgenstrahlung, sondern einer Messung der Protonendichte und von gewebespezifischen Relaxationszeiten basiert, muessen in der MR-PET alternative Verfahren zur Schwaechungskorrektur eingesetzt werden. Darueber hinaus bietet die MRT auch alternative Sequenz- und Akquisitionstechnologien, die es erlauben, bisherige Limitationen z. B. bzgl. der Bewegungskorrektur zu adressieren. Dieser Artikel berichtet ueber initiale klinische Erfahrungen mit einem voll integrierten MR-PET-System, wobei MR-Techniken zur Korrektur von Bewegungsartefakten, die Schwaechungskorrektur und die Reduktion von Metallartefakten im Zentrum stehen. (orig.)

  8. Acute injury of the ankle joint; Akutes Trauma des Sprunggelenks

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.J. [Univ. Klinik fuer Radiodiagnostik, Abt. fuer Osteologie und Besondere Klinische Einrichtung Magnet Resonanz, AKH, Wien (Austria)]|[Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)

    1999-01-01

    The diagnosis of lateral collateral ankle ligament trauma is based on patient history, clinical examination, and clinical stress tests. If the clinical stress test is positive, stress radiography could be performed. There is no consensus about the usefulness of stress radiography in acute ankle sprain, particularly about the cut-off talar tilt angle beyond which a two-ligament rupture would be certain, ranging from 5 to 30 . Today MRI is not used for this indication, although it allows, with controlled positioning of the foot and with defined sections, visualization of injured lateral collateral ankle ligaments. In ankle injuries, plain radiographs form the established basis of diagnostic imaging and can provide definitive answers in most cases. CT is used in complex fractures for complete visualization. MRI is the method of choice for several diagnostic problem cases, including occult fractures and post-traumatic avascular necrosis. In tendon injuries, MRI is important if ultrasound is not diagnostic. Generally, for the evaluation of acute ankle injuries, MRI is the most important second-step procedure when radiographs are nondiagnostic. (orig.) [Deutsch] Die Diagnose einer lateralen Bandverletzung beim frischen Sprunggelenkstrauma fusst auf der Anamnese, der klinischen Untersuchung und klinischen Stresstests. Bei positiven klinischen Stresstests kann eine Stressradiographie durchgefuehrt werden. Es gibt keine Uebereinstimmung fuer den Wert der Stressradiographie beim frischen Supinationstrauma des Sprunggelenks, insbesonders fuer den Winkel der Aufklappbarkeit bei einer Zweibandverletzung, der von 5 -30 reicht. Die MRT wird zur Zeit bei dieser Indikation nur in Einzelfaellen benutzt, obwohl sie mit definierter Fusspositionierung und Ausrichtung der Untersuchungsebene eine ausgezeichnete Beurteilung der Sprunggelenksbaende erlaubt. Bei knoecherner Sprunggelenksverletzungen ist die Verwendung des konventionellen Roentgen die etablierte Methode und meist

  9. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

    Science.gov (United States)

    Negahdar, M J; Kadbi, Mo; Kendrick, Michael; Stoddard, Marcus F; Amini, Amir A

    2016-03-01

    The utility of four-dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated. The method performs 4D flow acquisitions through a stack of interleaved spiral k-space readouts. Relative to conventional 4D flow, which performs Cartesian readout, the method has reduced echo time. Thus, reduced flow artifacts are observed when imaging high-speed stenotic flows. Four-dimensional spiral flow also provides significant savings in scan times relative to conventional 4D flow. In vitro experiments were performed under both steady and pulsatile flows in a phantom model of severe stenosis (one inch diameter at the inlet, with 87% area reduction at the throat of the stenosis) while imaging a 6-cm axial extent of the phantom, which included the Gaussian-shaped stenotic narrowing. In all cases, gradient strength and slew rate for standard clinical acquisitions, and identical field of view and resolution were used. For low steady flow rates, quantitative and qualitative results showed a similar level of accuracy between 4D spiral flow (echo time [TE] = 2 ms, scan time = 40 s) and conventional 4D flow (TE = 3.6 ms, scan time = 1:01 min). However, in the case of high steady flow rates, 4D spiral flow (TE = 1.57 ms, scan time = 38 s) showed better visualization and accuracy as compared to conventional 4D flow (TE = 3.2 ms, scan time = 51 s). At low pulsatile flow rates, a good agreement was observed between 4D spiral flow (TE = 2 ms, scan time = 10:26 min) and conventional 4D flow (TE = 3.6 ms, scan time = 14:20 min). However, in the case of high flow-rate pulsatile flows, 4D spiral flow (TE = 1.57 ms, scan time = 10:26 min) demonstrated better visualization as compared to conventional 4D flow (TE = 3.2 ms, scan time = 14:20 min). The feasibility of 4D spiral flow was also investigated in five normal volunteers and four subjects with mild-to-moderate aortic stenosis. The approach achieved TE = 1.68 ms and scan

  10. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A. [Ospedale S. Maria delle Grazie, Pozzuoli, NA (Italy). Servizio di Radiologia; Nunziata, A. [Ospedale S. Maria delle Grazie, Naples (Italy). Area di Diagnostica per Immagini

    2000-06-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyper attenuation in the arterial phase and hypo-iso attenuation in the portal and/or delayed phase, or with hypo-iso attenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hyper vascular and 1 hypo vascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemo embolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this

  11. Clinical use of digital retrospective image fusion of CT, MRI, FDG-PET and SPECT - fields of indications and results; Klinischer Einsatz der digitalen retrospektiven Bildfusion von CT, MRT, FDG-PET und SPECT - Anwendungsgebiete und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, A.J.; Niehues, S.M.; Amthauer, H.; Felix, R. [Campus Virchow-Klinikum, Klinik fuer Strahlenheilkunde, Charite, Universitaetsmedizin Berlin (Germany); Rohlfing, T. [Dept. of Neurosurgery, Stanford Univ. (United States); Hosten, N. [Inst. fuer Diagnostische Radiologie, Ernst-Moritz-Arndt-Univ. Greifswald (Germany)

    2004-12-01

    Purpose: To evaluate the feasibility and the clinical benefits of retrospective digital image fusion (PET, SPECT, CT and MRI). Materials and methods: In a prospective study, a total of 273 image fusions were performed and evaluated. The underlying image acquisitions (CT, MRI, SPECT and PET) were performed in a way appropriate for the respective clinical question and anatomical region. Image fusion was executed with a software program developed during this study. The results of the image fusion procedure were evaluated in terms of technical feasibility, clinical objective, and therapeutic impact. Results: The most frequent combinations of modalities were CT/PET (n = 156) and MRI/PET (n = 59), followed by MRI/SPECT (n = 28), CT/SPECT (n = 22) and CT/MRI (n = 8). The clinical questions included following regions (more than one region per case possible): neurocranium (n = 42), neck (n = 13), lung and mediastinum (n = 24), abdomen (n = 181), and pelvis (n = 65). In 92.6% of all cases (n = 253), image fusion was technically successful. Image fusion was able to improve sensitivity and specificity of the single modality, or to add important diagnostic information. Image fusion was problematic in cases of different body positions between the two imaging modalities or different positions of mobile organs. In 37.9% of the cases, image fusion added clinically relevant information compared to the single modality. Conclusion: For clinical questions concerning liver, pancreas, rectum, neck, or neurocranium, image fusion is a reliable method suitable for routine clinical application. Organ motion still limits its feasibility and routine use in other areas (e.g., thorax). (orig.)

  12. Degenerative cerebellar diseases and differential diagnoses; Degenerative Kleinhirnerkrankungen und Differenzialdiagnosen

    Energy Technology Data Exchange (ETDEWEB)

    Reith, W.; Roumia, S.; Dietrich, P. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2016-11-15

    Cerebellar syndromes result in distinct clinical symptoms, such as ataxia, dysarthria, dysmetria, intention tremor and eye movement disorders. In addition to the medical history and clinical examination, imaging is particularly important to differentiate other diseases, such as hydrocephalus and multi-infarct dementia from degenerative cerebellar diseases. Degenerative diseases with cerebellar involvement include Parkinson's disease, multiple system atrophy as well as other diseases including spinocerebellar ataxia. In addition to magnetic resonance imaging (MRI), nuclear medicine imaging investigations are also helpful for the differentiation. Axial fluid-attenuated inversion recovery (FLAIR) and T2-weighted sequences can sometimes show a signal increase in the pons as a sign of degeneration of pontine neurons and transverse fibers in the basilar part of the pons. The imaging is particularly necessary to exclude other diseases, such as normal pressure hydrocephalus (NPH), multi-infarct dementia and cerebellar lesions. (orig.) [German] Klinisch imponieren Kleinhirnsyndrome durch Ataxie, Dysarthrie, Dysmetrie, Intentionstremor und Augenbewegungsstoerungen. Neben der Anamnese und klinischen Untersuchung ist die Bildgebung v. a. wichtig um andere Erkrankungen wie Hydrozephalus und Multiinfarktdemenz von degenerativen Kleinhirnerkrankungen zu differenzieren. Zu den degenerativen Erkrankungen mit Kleinhirnbeteiligung gehoeren der Morbus Parkinson, die Multisystematrophie sowie weitere Erkrankungen einschliesslich der spinozerebellaeren Ataxien. Neben der MRT sind auch nuklearmedizinische Untersuchungen zur Differenzierung hilfreich. Axiale Fluid-attenuated-inversion-recovery(FLAIR)- und T2-gewichtete Sequenzen koennen mitunter eine Signalsteigerung im Pons als Ausdruck einer Degeneration der pontinen Neuronen und transversalen Bahnen im Brueckenfuss zeigen. Die Bildgebung ist aber v. a. notwendig, um andere Erkrankungen wie Normaldruckhydrozephalus

  13. Hemato-oncological imaging. Importance of hybrid procedures; Haematoonkologische Bildgebung. Stellenwert der Hybridverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Mayerhoefer, M.E. [Univ.-Klinik fuer Radiologie und Nuklearmedizin, Abteilung fuer Allgemeine und Kinderradiologie, Medizinische Universitaet Wien, Wien (Austria); Haug, A. [Univ.-Klinik fuer Radiologie und Nuklearmedizin, Abteilung fuer Nuklearmedizin, Medizinische Universitaet Wien, Wien (Austria)

    2016-07-15

    Biomedical imaging procedures play a major role in hemato-oncological diseases with respect to pre-therapeutic staging and assessment of treatment response. Originally, the therapeutic management was the domain of computed tomography (CT) and whole-body magnetic resonance imaging (MRI). Over the last decade these purely morphological techniques have gradually been replaced by hybrid imaging techniques, such as positron emission tomography-CT (PET/CT) and PET/MRI, which also provide metabolic and functional information. For lymphomas, the PET tracer 18F-fluorodeoxyglucose (18 F-FDG) is meanwhile so well-established that its use is a cornerstone of the Lugano classification; however, for multiple myeloma the search for an optimal PET tracer that can also detect early disease stages is still ongoing. Functional MRI techniques, such as diffusion-weighted imaging (DWI), perfusion-weighted imaging and dynamic contrast-enhanced imaging have shown promising results for both lymphomas and multiple myelomas. The PET/MRI technique can combine the different types of information due to its truly multiparametric approach. In the future PET/MRI could possibly become the hybrid imaging technique of choice for hemato-oncological diseases. (orig.) [German] Bildgebende Verfahren spielen bei haematoonkologischen Erkrankungen eine wesentliche Rolle fuer das Staging vor der Therapie und die Beurteilung des Therapieansprechens. Urspruenglich waren es v. a. die CT und die Ganzkoerper-MRT, welche die fuer das therapeutische Management relevanten Informationen lieferten. Im letzten Jahrzehnt erfolgte bei dieser Gruppe von Tumorerkrankungen jedoch eine Abkehr von den rein morphologischen Verfahren hin zu den Hybridverfahren Positronenemissionstomographie(PET)-CT und PET-MRT, welche auch metabolische und funktionelle Informationen liefern. Bei Lymphomen steht der PET-Tracer {sup 18}F-Fluordesoxyglukose ({sup 18}F-FDG) mittlerweile im Zentrum der Diagnostik und ist auch fest in der aktuellen

  14. Fetal MRI of pathological brain development; Fetale MRT der pathologischen Hirnentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.C. [Medizinische Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie, Zentrum fuer Anatomie und Zellbiologie; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.) [German] Aufgrund des hervorragenden Gewebekontrastes, der hohen raeumlichen Aufloesung und multiplanaren Moeglichkeiten erlaubt die fetale Magnetresonanztomographie (MRT) eine detaillierte Darstellung fetaler Hirnpathologien. Eine pathologische Hirnentwicklung kann sowohl auf Fehlbildungen als auch waehrend der Schwangerschaft erworbenen Stoerungen beruhen. Nachdem die weiteren Konsequenzen fuer die bestehende, aber auch fuer folgende Schwangerschaften zu einem grossen Teil von einer Differenzierung dieser Aetiologien abhaengig sein kann, ist ein Erkennen der jeweiligen Pathologie wesentlich. Die morphologische Praesentation erworbener und fehlbildungsbedingter Veraenderungen auf MR-Bildern ist u. U. sehr aehnlich. Besondere differenzialdiagnostische Probleme bereitet dabei das Vorliegen eines erweiterten Ventrikelsystems, das als Symptom unterschiedlichster Veraenderungen vorliegen kann. Anhand einer systematischen Darstellung mittels MR-erfassbarer morphologischer Details wird eine Anleitung gegeben, bei Bestehen dieses Leitsymptoms zu einer moeglichst genauen Diagnose zu kommen

  15. VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver; VIBE mit paralleler Akquisitionstechnik - eine neue Moeglichkeit der dynamischen kontrastverstaerkten MRT der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Dobritz, M.; Radkow, T.; Bautz, W.; Fellner, F.A. [Inst. fuer Diagnostische Radiologie, Friedrich-Alexander-Univ. Erlangen-Nuernberg (Germany); Nittka, M. [Siemens Medical Solutions, Erlangen (Germany)

    2002-06-01

    Leberlaesionen zu sammeln. Material und Methoden: 10 konsekutive Patienten mit verschiedenen pathologischen Befunden (HCC, Haemangiome, Metastasen, Zysten, Adenome) wurden an einem 1.5 T MRT-System untersucht. Zur Anwendung kamen folgende Sequenzen: T{sub 2} TSE und T{sub 1} FLASH nativ, nach Gadolinium-Gabe 6 VIBE-Sequenzen mit iPAT (TR/TE/Matrix/Partitionsdicke/Akquisitionszeit: 6.2 ms/3.2 ms/256 x 192/4 mm/13 s) sowie T{sub 1} FLASH mit Fettsaettigung. Zwei Untersucher beurteilten im Konsensus die einzelnen Sequenzen hinsichtlich Anzahl und Dignitiaet der Laesionen. Ergebnisse: Die VIBE-Sequenz zeigte sich ueberlegen in der Detektion arteriell hyperperfundierter Laesionen mit insgesamt 33 erkannten Herden. In der T{sub 2}-gewichteten TSE-Sequenz wurden 21 und in der nativen T{sub 1}-gewichteten GRE-Sequenz 20 Herde gefunden. Die diagnostische Sicherheit stieg in der VIBE-Sequenz gegenueber den anderen Sequenzen deutlich an. Zusammenfassung: Die VIBE-Sequenz mit iPAT ermoeglicht eine MRT der Leber in hoher oertlicher und zeitlicher Aufloesung, wodurch dynamische Kontrastinformationen ueber das gesamte Organ ermoeglicht werden. Dadurch koennte eine Verbesserung der Detektion fokaler Laesionen erreicht werden. (orig.)

  16. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. No significant differences in quantitative measures of image quality were found between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6 pitch 3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch = 3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom

  17. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    International Nuclear Information System (INIS)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H.

    2009-01-01

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6≤pitch≤3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  18. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H. [Siemens Healthcare, Computed Tomography, 91301 Forchheim, Germany and Department of Diagnostic Radiology, Eberhard-Karls-Universitaet, 72076 Tuebingen (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Siemens Healthcare, Computed Tomography, 91301 Forchheim (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2009-12-15

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  19. The value of multislice spiral CT in transcatheter arterial chemoembolization of the hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Li Zhigang; Zhao Junjing; Shi Gaofeng; Li Shunzong; Han Pengyin; Yang Guang; Liang Guoqing; Wang Hongguang; Huang Jingxiang

    2006-01-01

    Objective: To evaluate the value of multislice spiral CT (MSCT) in transcatheter arterial chemoembolization of the hepatocellular carcinoma. Methods: MSCT were performed in 54 cases of HCC before interventional procedure. CT findings of hepatic artery phase, portal venous phase and hepatic venous phase were observed respectively. CTA were done in 12 cases, the anatomy of celiac artery and its branches were observed. The schemes of interventional therapy were worked out according to the findings of MSCT. The demonstration of lesions and its complications were compared between CT and DSA. Reconstruction of celiac artery branches used the technique of VRT, MIP or MPR. Results: MSCT showed 225 lesions, 10 cases tumor thrombosis of portal vein, 1 case hepatic arteriovenous shunt, and 13 cases hepatic arterioportal shunt. Positive rate of MSCT in showing number of tumor lesions, tumor thrombosis in portal vein was slightly higher than that of DSA, but there was no significant difference (P>0.05). Showing of 3D reconstruction of celiac artery branches in CTA is better than that in DSA, Showing of angles between celiac artery and abdominal aorta in MSCT is more convenient than that in DSA. MSCT showed 5 cases hepatic artery original abnormality. The results were in accord with that in DSA. Five cases were demonstrated of multiple supply blood vessels of tumor in MSCT, It was slightly lower than that of DSA. Conclusion: MSCT is of importance for guidance of transcatheter arterial chemoembolization of the hepatocellular carcinoma, delay time of CT scan is the key to the showing of lesions and blood vessels. (authors)

  20. The technique advantages of 16-detector multic-slice spiral CT in evaluating combined pulmonary and deep vein thromboembolism

    International Nuclear Information System (INIS)

    Xia Shuang; Qi Ji; Lei Xinwei; Wen Lianqing; Li Yiming; Liu Jisheng

    2004-01-01

    Objective: To study the scanning technique of 16-detector multic-slice spiral CT(MSCT) for combined pulmonary artery and deep vein of lower limb in pulmonary thromboembolism (PE) patients. Methods: Forty suspected pulmonary thromboembolism patients were performed both pulmonary artery angiography (CTA) and indirect deep vein venography (CTV) on 16-detector MSCT. The parameters of the latter as following: total contrast volume 120-150 ml, injection rate 4.0-4.5 ml/s (from antecubital vein), delay time 4.0 for CTA 20-23 s, CTV 120-180 s, collimation for CTA 1.25 mm and 0.625 mm, CTV 2.5 mm, scan range of CTV: from popliteal vein to the level of bilateral renal vein into the inferior vena cava. Postprocessing include MPR, MIP, and VR. The test was used to analyzed the images. Results: Twenty five patients had both pulmonary thromboembolism (PE) and deep vein thromboembolism (DVT), 8 patients had only DVT, 2 had only PE, and 5 had neither. There was no difference between different collimation in depicting thrombus. The CT value number of enhanced pulmonary artery and lower deep vein was obviously higher than the thrombus. The value of MPR, MIP, VR for PE was 100%, 100%, and 65%, The value of MPR, MIP, VR for DVT is 100%, 60%, and 50%. Conclusion: The technique of combined pulmonary CTA and deep vein CTV of 16-detector MSCT will provide a new modality for pulmonary thromboembolism patients. (author)