  1. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  2. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    OpenAIRE

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian...

  3. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  4. Integrated navigation and control software system for MRI-guided robotic prostate interventions.

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S; DiMaio, Simon P; Gobbi, David G; Csoma, Csaba; Mewes, Philip W; Fichtinger, Gabor; Tempany, Clare M; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called "workphases" that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. Copyright 2009 Elsevier Ltd. All rights reserved.

  5. Integrated navigation and control software system for MRI-guided robotic prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S.; DiMaio, Simon P.; Gobbi, David G.; Csoma, Csaba; Mewes, Philip W.; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called “workphases” that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6 mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. PMID:19699057

  6. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    International Nuclear Information System (INIS)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A; Duiveman, Ed; Van Schelven, Leonard J; De Leeuw, Hendrik

    2010-01-01

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  7. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    Energy Technology Data Exchange (ETDEWEB)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); Duiveman, Ed; Van Schelven, Leonard J [Medical Technology and Clinical Physics, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); De Leeuw, Hendrik [Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands)], E-mail: M.R.vandenBosch@umcutrecht.nl

    2010-03-07

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  8. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    Science.gov (United States)

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  9. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, Martijn G. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); University Medical Centre Nijmegen, Department of Radiology, Nijmegen (Netherlands); Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Rothgang, Eva [Pattern Recognition Lab, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen (Germany); Center for Applied Medical Imaging, Siemens Corporate Research (Germany); Center for Applied Medical Imaging, Siemens Corporate Research, Baltimore, MD (United States); Misra, Sarthak [University of Twente, MIRA-Institute of Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2012-02-15

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  10. Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    International Nuclear Information System (INIS)

    Schouten, Martijn G.; Bomers, Joyce G.R.; Yakar, Derya; Huisman, Henkjan; Bosboom, Dennis; Scheenen, Tom W.J.; Fuetterer, Jurgen J.; Rothgang, Eva; Misra, Sarthak

    2012-01-01

    To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures. (orig.)

  11. A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy

    Science.gov (United States)

    Li, Gang; Su, Hao; Shang, Weijian; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Fischer, Gregory S.

    2014-01-01

    Intra-operative medical imaging enables incorporation of human experience and intelligence in a controlled, closed-loop fashion. Magnetic resonance imaging (MRI) is an ideal modality for surgical guidance of diagnostic and therapeutic procedures, with its ability to perform high resolution, real-time, high soft tissue contrast imaging without ionizing radiation. However, for most current image-guided approaches only static pre-operative images are accessible for guidance, which are unable to provide updated information during a surgical procedure. The high magnetic field, electrical interference, and limited access of closed-bore MRI render great challenges to developing robotic systems that can perform inside a diagnostic high-field MRI while obtaining interactively updated MR images. To overcome these limitations, we are developing a piezoelectrically actuated robotic assistant for actuated percutaneous prostate interventions under real-time MRI guidance. Utilizing a modular design, the system enables coherent and straight forward workflow for various percutaneous interventions, including prostate biopsy sampling and brachytherapy seed placement, using various needle driver configurations. The unified workflow compromises: 1) system hardware and software initialization, 2) fiducial frame registration, 3) target selection and motion planning, 4) moving to the target and performing the intervention (e.g. taking a biopsy sample) under live imaging, and 5) visualization and verification. Phantom experiments of prostate biopsy and brachytherapy were executed under MRI-guidance to evaluate the feasibility of the workflow. The robot successfully performed fully actuated biopsy sampling and delivery of simulated brachytherapy seeds under live MR imaging, as well as precise delivery of a prostate brachytherapy seed distribution with an RMS accuracy of 0.98mm. PMID:25076821

  12. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2008-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot perform...

  13. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    OpenAIRE

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2010-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor....

  14. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  15. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  16. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-13

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.

  17. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2011-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. PMID:21686038

  18. Software Strategy for Robotic Transperineal Prostate Therapy in Closed-Bore MRI

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S.; Csoma, Csaba; DiMaio, Simon P.; Gobbi, David G.; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2009-01-01

    A software strategy to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and open-source navigation software are connected to one another via Ethernet to exchange commands, coordinates, and images. Six states of the system called “workphases” are defined based on the clinical scenario to synchronize behaviors of all components. The wizard-style user interface allows easy following of the clinical workflow. On top of this framework, the software provides features for intuitive needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MRI. These features are supported by calibration of robot and image coordinates by the fiducial-based registration. The performance test shows that the registration error of the system was 2.6 mm in the prostate area, and it displayed real-time 2D image 1.7 s after the completion of image acquisition. PMID:18982666

  19. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  20. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S.; Iordachita, Iulian; Seifabadi, Reza; Cho, Bong Joon; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2013-01-01

    Purpose To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. Methods We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle towards a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between −5.7° and 5.7° horizontally and between −5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. Results The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5 mm along the horizontal axis and 0.8 ± 0.8 mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4 mm. Conclusions Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study. PMID:22678723

  1. Towards Clinically Optimized MRI-guided Surgical Manipulator for Minimally Invasive Prostate Percutaneous Interventions: Constructive Design*

    Science.gov (United States)

    Eslami, Sohrab; Fischer, Gregory S.; Song, Sang-Eun; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian

    2013-01-01

    This paper undertakes the modular design and development of a minimally invasive surgical manipulator for MRI-guided transperineal prostate interventions. Severe constraints for the MRI-compatibility to hold the minimum artifact on the image quality and dimensions restraint of the bore scanner shadow the design procedure. Regarding the constructive design, the manipulator kinematics has been optimized and the effective analytical needle workspace is developed and followed by proposing the workflow for the manual needle insertion. A study of the finite element analysis is established and utilized to improve the mechanism weaknesses under some inevitable external forces to ensure the minimum structure deformation. The procedure for attaching a sterile plastic drape on the robot manipulator is discussed. The introduced robotic manipulator herein is aimed for the clinically prostate biopsy and brachytherapy applications. PMID:24683502

  2. Diagnostic Accuracy of Robot-Guided, Software Based Transperineal MRI/TRUS Fusion Biopsy of the Prostate in a High Risk Population of Previously Biopsy Negative Men

    Directory of Open Access Journals (Sweden)

    Malte Kroenig

    2016-01-01

    Full Text Available Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4. Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n=2080. Overall detection rate of clinically significant PCa was 44.2% (23/52 and 50.0% (26/52 for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6–14.0 and 32 (IQR: 24–32 for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52 for target and 3.9% (2/52 for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.

  3. MRI-guided robot for needle interventions in the prostate

    NARCIS (Netherlands)

    van den Bosch, M.R.

    2011-01-01

    Magnetic resonance imaging (MRI) is applied to non-invasively visualize patient’s anatomy and tumour suspicious regions with superior soft tissue contrast. Amongst others, online MRI is valuable in the diagnostic and treatment techniques for prostate cancer. Clinical MR scanners are suitable to

  4. MRI-guided biopsies and minimally invasive therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Sangeet Ghai

    2015-01-01

    Full Text Available Recent advances in multiparametric magnetic resonance imaging (mp-MRI have led to a paradigm shift in the diagnosis and management of prostate cancer (PCa. Its sensitivity in detecting clinically significant cancer and the ability to localize the tumor within the prostate gland has opened up discussion on targeted diagnosis and therapy in PCa. Use of mp-MRI in conjunction with prostate-specific antigen followed by targeted biopsy allows for a better diagnostic pathway than transrectal ultrasound (TRUS biopsy and improves the diagnosis of PCa. Improved detection of PCa by mp-MRI has also opened up opportunities for focal therapy within the organ while reducing the incidence of side-effects associated with the radical treatment methods for PCa. This review discusses the evidence and techniques for in-bore MRI-guided prostate biopsy and provides an update on the status of MRI-guided targeted focal therapy in PCa.

  5. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    OpenAIRE

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2008-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challengin...

  6. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  7. Clinical outcome following a low-suspicion multiparametric prostate MRI or benign MRI-guided biopsy to detect prostate cancer

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2017-01-01

    follow-up [132/156 (85%)] had decreasing levels of prostate-specific-antigen and could be monitored in primary care. CONCLUSION: A low-suspicion MRI in men with prior negative systematic biopsies has a high negative predictive value in ruling out longer term significant cancer. Therefore, immediate...... repeated biopsies are of limited clinical value and could be avoided even if prostate-specific-antigen levels are persistently elevated.......PURPOSE: To assess the future risk of detecting significant prostate cancer following either a low-suspicion MRI or suspicious MRI with benign MRI-guided biopsies in men with prior negative systematic biopsies. MATERIALS AND METHODS: 289 prospectively enrolled men underwent MRI followed by repeated...

  8. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  9. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  10. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    Science.gov (United States)

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2017-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually observable image artifact. The targeting accuracy is evaluated with optical tracking system and gelatin phantom under live MRI-guidance with Root Mean Square (RMS) errors of 1.94 and 2.17 mm respectively. Furthermore, we demonstrate that the robot has kinematic redundancy to reach the same target through different paths. This was evaluated in both free space and MRI-guided gelatin phantom trails, with RMS errors of 0.48 and 0.59 mm respectively. As the first of its kind, MRI-guided targeted concentric tube needle placements with ex vivo porcine liver are demonstrated with 4.64 mm RMS error through closed-loop control of the piezoelectrically-actuated robot. PMID:26983842

  11. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  12. Robotic System for MRI-Guided Stereotactic Neurosurgery

    Science.gov (United States)

    Li, Gang; Cole, Gregory A.; Shang, Weijian; Harrington, Kevin; Camilo, Alex; Pilitsis, Julie G.; Fischer, Gregory S.

    2015-01-01

    Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for Deep Brain Stimulation (DBS) lead placement. The work describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio (SNR) variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with 3-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle. PMID:25376035

  13. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  14. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    OpenAIRE

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2016-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually...

  15. Multiparametric MRI fusion-guided biopsy for the diagnosis of prostate cancer.

    Science.gov (United States)

    Kesch, Claudia; Schütz, Viktoria; Dieffenbacher, Svenja; Bonekamp, David; Hadaschik, Boris Alexander; Hohenfellner, Markus; Radtke, Jan P

    2018-03-01

    To discuss the timing, benefits, limitations and current controversies of multiparametric magnet resonance imaging (mpMRI) combined with fusion-guided biopsy and consider how additional incorporation of multivariable risk stratification might further improve prostate cancer diagnosis. MpMRI has been proven advantageous over standard practice for biopsy-naïve men and men with previous biopsy in large prospective studies providing level 1b evidence. Upfront multivariable risk stratification followed by or combined with mpMRI further improves diagnostic accuracy. Regarding active surveillance, mpMRI in combination with fusion biopsy can support initial candidate selection and may help to monitor disease progression. mpMRI and fusion biopsy, however, do not spare failure and conflicting data exists to what extend (systematic) biopsies can be omitted. Integration of mpMRI into the diagnostic pathway for prostate cancer is beneficial; yet more prospective and randomized data is needed to establish reliable procedure standards after mpMRI acquisition.

  16. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  17. Documenting the location of systematic transrectal ultrasound-guided prostate biopsies: correlation with multi-parametric MRI.

    Science.gov (United States)

    Turkbey, Baris; Xu, Sheng; Kruecker, Jochen; Locklin, Julia; Pang, Yuxi; Shah, Vijay; Bernardo, Marcelino; Baccala, Angelo; Rastinehad, Ardeshir; Benjamin, Compton; Merino, Maria J; Wood, Bradford J; Choyke, Peter L; Pinto, Peter A

    2011-03-29

    During transrectal ultrasound (TRUS)-guided prostate biopsies, the actual location of the biopsy site is rarely documented. Here, we demonstrate the capability of TRUS-magnetic resonance imaging (MRI) image fusion to document the biopsy site and correlate biopsy results with multi-parametric MRI findings. Fifty consecutive patients (median age 61 years) with a median prostate-specific antigen (PSA) level of 5.8 ng/ml underwent 12-core TRUS-guided biopsy of the prostate. Pre-procedural T2-weighted magnetic resonance images were fused to TRUS. A disposable needle guide with miniature tracking sensors was attached to the TRUS probe to enable fusion with MRI. Real-time TRUS images during biopsy and the corresponding tracking information were recorded. Each biopsy site was superimposed onto the MRI. Each biopsy site was classified as positive or negative for cancer based on the results of each MRI sequence. Sensitivity, specificity, and receiver operating curve (ROC) area under the curve (AUC) values were calculated for multi-parametric MRI. Gleason scores for each multi-parametric MRI pattern were also evaluated. Six hundred and 5 systemic biopsy cores were analyzed in 50 patients, of whom 20 patients had 56 positive cores. MRI identified 34 of 56 positive cores. Overall, sensitivity, specificity, and ROC area values for multi-parametric MRI were 0.607, 0.727, 0.667, respectively. TRUS-MRI fusion after biopsy can be used to document the location of each biopsy site, which can then be correlated with MRI findings. Based on correlation with tracked biopsies, T2-weighted MRI and apparent diffusion coefficient maps derived from diffusion-weighted MRI are the most sensitive sequences, whereas the addition of delayed contrast enhancement MRI and three-dimensional magnetic resonance spectroscopy demonstrated higher specificity consistent with results obtained using radical prostatectomy specimens.

  18. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  19. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  20. In-bore setup and software for 3T MRI-guided transperineal prostate biopsy

    International Nuclear Information System (INIS)

    Tokuda, Junichi; Tuncali, Kemal; Song, Sang-Eun; Fedorov, Andriy; Oguro, Sota; Fennessy, Fiona M; Tempany, Clare M; Hata, Nobuhiko; Iordachita, Iulian; Lasso, Andras

    2012-01-01

    MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support MRI-guided transperineal prostate biopsy in a wide-bore 3 T MRI scanner. The setup consists of a specially designed tabletop and a needle-guiding template with a Z-frame that gives a physician access to the perineum of the patient at the imaging position and allows the physician to perform MRI-guided transperineal biopsy without moving the patient out of the scanner. The software and Z-frame allow registration of the template, target planning and biopsy guidance. Initially, we performed phantom experiments to assess the accuracy of template registration and needle placement in a controlled environment. Subsequently, we embarked on our clinical trial (N = 10). The phantom experiments showed that the translational errors of the template registration along the right–left (RP) and anterior–posterior (AP) axes were 1.1 ± 0.8 and 1.4 ± 1.1 mm, respectively, while the rotational errors around the RL, AP and superior–inferior axes were (0.8 ± 1.0)°, (1.7 ± 1.6)° and (0.0 ± 0.0)°, respectively. The 2D root-mean-square (RMS) needle-placement error was 3 mm. The clinical biopsy procedures were safely carried out in all ten clinical cases with a needle-placement error of 5.4 mm (2D RMS). In conclusion, transperineal prostate biopsy in a wide-bore 3T scanner is feasible using our custom-made tabletop setup and software, which supports manual needle placement without moving the patient out of the magnet. (paper)

  1. Imaging of prostate cancer: a platform for 3D co-registration of in-vivo MRI ex-vivo MRI and pathology

    Science.gov (United States)

    Orczyk, Clément; Mikheev, Artem; Rosenkrantz, Andrew; Melamed, Jonathan; Taneja, Samir S.; Rusinek, Henry

    2012-02-01

    Objectives: Multi-parametric MRI is emerging as a promising method for prostate cancer diagnosis. prognosis and treatment planning. However, the localization of in-vivo detected lesions and pathologic sites of cancer remains a significant challenge. To overcome this limitation we have developed and tested a system for co-registration of in-vivo MRI, ex-vivo MRI and histology. Materials and Methods: Three men diagnosed with localized prostate cancer (ages 54-72, PSA levels 5.1-7.7 ng/ml) were prospectively enrolled in this study. All patients underwent 3T multi-parametric MRI that included T2W, DCEMRI, and DWI prior to robotic-assisted prostatectomy. Ex-vivo multi-parametric MRI was performed on fresh prostate specimen. Excised prostates were then sliced at regular intervals and photographed both before and after fixation. Slices were perpendicular to the main axis of the posterior capsule, i.e., along the direction of the rectal wall. Guided by the location of the urethra, 2D digital images were assembled into 3D models. Cancer foci, extra-capsular extensions and zonal margins were delineated by the pathologist and included in 3D histology data. A locally-developed software was applied to register in-vivo, ex-vivo and histology using an over-determined set of anatomical landmarks placed in anterior fibro-muscular stroma, central. transition and peripheral zones. The mean root square distance across corresponding control points was used to assess co-registration error. Results: Two specimens were pT3a and one pT2b (negative margin) at pathology. The software successfully fused invivo MRI. ex-vivo MRI fresh specimen and histology using appropriate (rigid and affine) transformation models with mean square error of 1.59 mm. Coregistration accuracy was confirmed by multi-modality viewing using operator-guided variable transparency. Conclusion: The method enables successful co-registration of pre-operative MRI, ex-vivo MRI and pathology and it provides initial evidence

  2. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael, E-mail: michael.meier@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Homsi, Rami, E-mail: rami.homsi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Kukuk, Guido, E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Wolter, Karsten, E-mail: karsten.wolter@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Decker, Georges, E-mail: georges.decker@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Fischer, Stefan, E-mail: stefan.fischer@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Marx, Christian, E-mail: christian.marx@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schmeel, Frederic Carsten, E-mail: carsten.schmeel@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Block, Wolfgang, E-mail: wolfgang.block@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Sprinkart, Alois Martin, E-mail: sprinkart@uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Schild, Hans Heinz, E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, 53127 Bonn (Germany); Willinek, Winfried, E-mail: w.willinek@bk-trier.de [Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Hospital of the Barmherzige Brüder Trier, Nordallee 1, 54292 Trier (Germany)

    2016-12-15

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  3. In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Homsi, Rami; Kukuk, Guido; Wolter, Karsten; Decker, Georges; Fischer, Stefan; Marx, Christian; Schmeel, Frederic Carsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Willinek, Winfried

    2016-01-01

    Purpose: To systematically analyze risk factors for complications of in-bore transrectal MRI-guided prostate biopsies (MRGB). Materials and methods: 90 patients, who were scheduled for MRGB were included for this study. Exclusion criteria were coagulation disorders, therapy with anticoagulant drugs, and acute infections of the urinary and the lower gastrointestinal tract. Directly after, one week and one year after the biopsy, we assessed biopsy related complications (e.g. hemorrhages or signs of prostatitis). Differences between patients with and without complications were analyzed regarding possible risk factors: age, prostate volume, number of taken samples, biopsy duration, biopsy of more than one lesion, diabetes, arterial hypertension, hemorrhoids, benign prostate hyperplasia, carcinoma or prostatitis (according to histopathological analysis), and lesion localization. Complications were classified according to the Clavien-Dindo classification. Results: We observed 15 grade I complications in 90 biopsies (16.7%) with slight hematuria in 9 cases (10%), minor vasovagal reactions in 4 cases (4.4%), and urinary retention and positioning-related facial dysesthesia in 1 case each (1.1%). One patient showed acute prostatitis requiring antibiotics as the only grade II complication (1.1%). There were no adverse events that occurred later than one week. Complications grade III or higher such as pelvic abscesses, urosepsis or severe hemorrhages were not seen. There were no significant associations between the assessed risk factors and biopsy-related complications. Conclusion: In-bore transrectal MRI-guided prostate biopsies can be considered safe procedures in the diagnosis of prostate cancer with very low complication rates. There seem to be no risk factors for complications.

  4. A robotic device for MRI-guided prostate brachytherapy

    NARCIS (Netherlands)

    Lagerburg, V.

    2008-01-01

    One of the treatment options for prostate cancer is brachytherapy with iodine-125 sources. In prostate brachytherapy a high radiation dose is delivered to the prostate with a steep dose fall off to critical surrounding organs. The implantation of the iodine sources is currently performed under

  5. Atlas-based deformable image registration for MRI-guided prostate radiation therapy

    International Nuclear Information System (INIS)

    Dowling, J.; Fripp, J.; Salvado, O.; Lambert, J.; Denham, J.W.; Capp, A.; Grer, P.B.; Parker, J.

    2010-01-01

    Full text: To develop atlas-based deformable image registration methods to automatically segment organs and map electron densities to pelvic MRI scans for MRI-guided radiation therapy. Methods An MRT pelvic atlas and corresponding CT atlas were developed based on whole pelvic T 2 MRI scans and CT scans for 39 patients. Expert manual segmentations on both MRI and CT scans were obtained. The atlas was deformably registered to the individual patient MRI scans for automatic prostate, rectum, bladder and bone segmentation. These were compared to the manual segmentations using the Dice overlap coefficient. The same deformation vectors were then applied to the CT-atlas to produce pseudo-CT scans that correspond to the patient MRI scan anatomy but are populated with Hounsfield units. The original patient plan was recalculated on the pseudo-CT and compared to the original CT plan and bulk density plans on the MRI scans. Results Dice coefficient results were high (>0.8) for bone and prostate but lower (<0.7) for bladder and rectum which exhibit greater changes in shape and volume. Doses calculated on pseudo-CT scans were within 3% of original patient plans. Two sources of discrepancy were found; MR anatomy differences from CT due to patient setup differences at the MR scanner. and Hounsfield unit differences for bone in the pseudo-CT from original CT. Patient setup will be adressed with a

  6. Image guided prostate cancer treatments

    Energy Technology Data Exchange (ETDEWEB)

    Bard, Robert L. [Bard Cancer Center, Biofoundation for Angiogenesis Research and Development, New York, NY (United States); Fuetterer, Jurgen J. [Radboud Univ. Nijmegen, Medical Centre (Netherlands). Dept. of Radiology; Sperling, Dan (ed.) [Sperling Prostate Center, Alpha 3TMRI, New York, NY (United States)

    2014-07-01

    Systematic overview of the application of ultrasound and MRI in the diagnosis and treatment of diseases of the lower urinary tract. Detailed information on image-guided therapies, including focused ultrasound, photodynamic therapy, and microwave and laser ablation. Numerous high-quality illustrations based on high-end equipment. Represents the state of the art in Non Invasive Imaging and Minimally Invasive Ablation Treatment (MIAT). Image-Guided Prostate Cancer Treatments is a comprehensive reference and practical guide on the technology and application of ultrasound and MRI in the male pelvis, with special attention to the prostate. The book is organized into three main sections, the first of which is devoted to general aspects of imaging and image-guided treatments. The second section provides a systematic overview of the application of ultrasound and MRI to the diagnosis and treatment of diseases of the lower urinary tract. Performance of the ultrasound and MRI studies is explained, and the normal and abnormal pathological anatomy is reviewed. Correlation with the ultrasound in the same plane is provided to assist in understanding the MRI sequences. Biopsy and interventional procedures, ultrasound-MRI fusion techniques, and image-guided therapies, including focused ultrasound, photodynamic therapy, microwave and laser ablation, are all fully covered. The third section focuses on securing treatment effectiveness and the use of follow-up imaging to ensure therapeutic success and detect tumor recurrence at an early stage, which is vital given that prompt focal treatment of recurrence is very successful. Here, particular attention is paid to the role of Doppler ultrasound and DCE-MRI technologies. This book, containing a wealth of high-quality illustrations based on high-end equipment, will acquaint beginners with the basics of prostate ultrasound and MRI, while more advanced practitioners will learn new skills, means of avoiding pitfalls, and ways of effectively

  7. In-Bore Prostate Transperineal Interventions with an MRI-guided Parallel Manipulator: System Development and Preliminary Evaluation

    Science.gov (United States)

    Eslami, Sohrab; Shang, Weijian; Li, Gang; Patel, Nirav; Fischer, Gregory S.; Tokuda, Junichi; Hata, Nobuhiko; Tempany, Clare M.; Iordachita, Iulian

    2015-01-01

    Background The robot-assisted minimally-invasive surgery is well recognized as a feasible solution for diagnosis and treatment of the prostate cancer in human. Methods In this paper the kinematics of a parallel 4 Degrees-of-Freedom (DOF) surgical manipulator designed for minimally invasive in-bore prostate percutaneous interventions through the patient's perineum. The proposed manipulator takes advantage of 4 sliders actuated by MRI-compatible piezoelectric motors and incremental rotary encoders. Errors, mostly originating from the design and manufacturing process, need to be identified and reduced before the robot is deployed in the clinical trials. Results The manipulator has undergone several experiments to evaluate the repeatability and accuracy of the needle placement which is an essential concern in percutaneous prostate interventions. Conclusion The acquired results endorse the sustainability, precision (about 1 mm in air (in x or y direction) at the needle's reference point) and reliability of the manipulator. PMID:26111458

  8. MRI of the prostate: potential role of robots

    NARCIS (Netherlands)

    Fütterer, Jurgen J.; Misra, Sarthak; Macura, Katarzyna J.

    2010-01-01

    Prostate cancer is the most frequently diagnosed malignancy in the male population. Transrectal ultrasound- guided biopsy is still the imaging modality of choice in detecting prostate cancer. However, with prostate cancer being detected at an earlier stage, most prostate cancers tend to be isoechoic

  9. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  10. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.

    Science.gov (United States)

    Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco

    2018-02-01

    To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason  7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.

  11. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  12. The PROSPER robot for prostate brachytherapy: design, development and preclinical evaluation

    International Nuclear Information System (INIS)

    Long, J.A.

    2012-01-01

    Objectives: reporting the design, development and experiments of a new robotic system for prostate brachytherapy including prostate tracking and MRI to Ultrasound registration. Material and methods: a robot for trans-perineal needle insertion has been developed. It includes the ability to track the prostate position and shape. Experiments on 90 targets inside 9 deformable phantoms have been conducted. A feasibility on 2 cadavers has also been performed. The robot had to place glass seeds simulating brachytherapy seeds as close as possible to physical targets included into the phantom or inside the prostates. A post-operative CT scan of the phantom or prostate was performed in order to measure the accuracy of the system. Results: the median accuracy was 2.73 mm with a median prostate motion of 5.46 mm. The accuracy in the base region was superior to the accuracy in the apex region (2.28 mm vs 3.83 mm, p≤0.01) and was not significantly different for horizontal or oblique needles (2.7 vs 2.82 mm, p=0.18). Cadaver experiments demonstrated that the approach was feasible and that the robot could be used in a real clinical environment. Conclusion: the robot for prostate brachytherapy is the first system enabling prostate tracking. Targets can be accurately reached despite prostate motion and deformation. It could be applied to focal therapy for prostate cancer. (author)

  13. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion

    NARCIS (Netherlands)

    Venderink, W.; Govers, T.M.; Rooij, M. de; Futterer, J.J.; Sedelaar, J.P.M.

    2017-01-01

    OBJECTIVE: Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. MATERIALS AND METHODS: A decision tree and Markov model were

  14. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  15. A MR-conditional High-torque Pneumatic Stepper Motor for MRI-guided and Robot-assisted Intervention

    Science.gov (United States)

    Chen, Yue; Kwok, Ka-Wai; Tse, Zion Tsz Ho

    2015-01-01

    Magnetic Resonance Imaging allows for visualizing detailed pathological and morphological changes of soft tissue. This increasingly attracts attention on MRI-guided intervention; hence, MR-conditional actuations have been widely investigated for development of image-guided and robot-assisted surgical devices under the MRI. This paper presents a simple design of MR-conditional stepper motor which can provide precise and high-torque actuation without adversely affecting the MR image quality. This stepper motor consists of two MR-conditional pneumatic cylinders and the corresponding supporting structures. Alternating the pressurized air can drive the motor to rotate each step in 3.6° with the motor coupled to a planetary gearbox. Experimental studies were conducted to validate its dynamics performance. Maximum 800mNm output torque can be achieved. The motor accuracy independently varied by two factors: motor operating speed and step size, was also investigated. The motor was tested within a Siemens 3T MRI scanner. The image artifact and the signal-to-noise ratio (SNR) were evaluated in order to study its MRI compliancy. The results show that the presented pneumatic stepper motor generated 2.35% SNR reduction in MR images and no observable artifact was presented besides the motor body itself. The proposed motor test also demonstrates a standard to evaluate the motor capability for later incorporation with motorized devices used in robot-assisted surgery under MRI. PMID:24957635

  16. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    Science.gov (United States)

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  17. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  18. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P.; Margreiter, M.

    2011-01-01

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [de

  19. Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun K.; Buzurovic, Ivan; Huang Ke; Showalter, Timothy; Dicker, Adam P.; Yu, Yan

    2011-01-01

    Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward improved reliability. The MTBF

  20. Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Podder, Tarun K.; Buzurovic, Ivan; Huang Ke; Showalter, Timothy; Dicker, Adam P.; Yu, Yan [Department of Radiation Oncology, Kimmel Cancer Center (NCI-designated), Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States)

    2011-01-15

    Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward

  1. Multiparametric MRI in men with clinical suspicion of prostate cancer undergoing repeat biopsy

    DEFF Research Database (Denmark)

    Boesen, Lars; Nørgaard, Nis; Løgager, Vibeke

    2018-01-01

    Background Multiparametric magnetic resonance imaging (mpMRI) can improve detection of clinically significant prostate cancer (csPCa). Purpose To compare mpMRI score subgroups to systematic transrectal ultrasound-guided biopsies (TRUSbx) and prostate-specific antigen (PSA)-based findings...

  2. Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Anthony B [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Diederich, Chris J [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Nau, William H [Thermal Therapy Research Group, UCSF Radiation Oncology, San Francisco, CA (United States); Gill, Harcharan [Department of Urology, Stanford University, Stanford, CA (United States); Bouley, Donna M [Department of Comparative Medicine, Stanford University, Stanford, CA (United States); Daniel, Bruce [Department of Radiology, Stanford University, Stanford, CA (United States); Rieke, Viola [Department of Radiology, Stanford University, Stanford, CA (United States); Butts, R Kim [Department of Radiology, Stanford University, Stanford, CA (United States); Sommer, Graham [Department of Radiology, Stanford University, Stanford, CA (United States)

    2004-01-21

    Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the tubular applicator ) produced coagulated zones covering a wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, {approx}8 MHz) generated thermal lesions of {approx}30 extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 each) demonstrated controllable coagulation of a 270 contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.

  3. MRI of the prostate. Recommendations on patient preparation and scanning protocol

    International Nuclear Information System (INIS)

    Franiel, Tobias; Quentin, Michael; Schimmoeller, Lars; Mueller-Lisse, Ullrich Gerd; Asbach, Patrick; Roedel, Stefan; Willinek, Winfried; Hueper, Katja; Beyersdorff, Dirk; Roethke, Matthias

    2017-01-01

    The Working Group Uroradiology and Urogenital Diagnosis of the German Roentgen Society has developed uniform recommendations for the preparation and implementation of prostate MRI. In the first part detailed recommendations are given in tabular form regarding 1. anamnestic data before prostate MRI, 2. termination of examinations and preparation of examinations, 3. examination protocol and 4. MRI-guided in-bore biopsy. In the second part, the recommendations are discussed in detail and relevant background information is provided.

  4. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2013-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scan...

  5. Is the Ellipsoid Formula the New Standard for 3-Tesla MRI Prostate Volume Calculation without Endorectal Coil?

    Science.gov (United States)

    Haas, Matthias; Günzel, Karsten; Miller, Kurt; Hamm, Bernd; Cash, Hannes; Asbach, Patrick

    2017-01-01

    Prostate volume in multiparametric MRI (mpMRI) is of clinical importance. For 3-Tesla mpMRI without endorectal coil, there is no distinctive standard for volume calculation. We tested the accuracy of the ellipsoid formula with planimetric volume measurements as reference and investigated the correlation of gland volume and cancer detection rate on MRI/ultrasound (MRI/US) fusion-guided biopsy. One hundred forty-three patients with findings on 3-Tesla mpMRI suspicious of cancer and subsequent MRI/US fusion-guided targeted biopsy and additional systematic biopsy were analyzed. T2-weighted images were used for measuring the prostate diameters and for planimetric volume measurement by a segmentation software. Planimetric and calculated prostate volumes were compared with clinical data. The median prostate volume was 48.1 ml (interquartile range (IQR) 36.9-62.1 ml). Volume calculated by the ellipsoid formula showed a strong concordance with planimetric volume, with a tendency to underestimate prostate volume (median volume 43.1 ml (IQR 31.2-58.8 ml); r = 0.903, p Tesla mpMRI without endorectal coil. It allows a fast, valid volume calculation in prostate MRI datasets. © 2016 S. Karger AG, Basel.

  6. SU-F-BRA-04: Prostate HDR Brachytherapy with Multichannel Robotic System

    International Nuclear Information System (INIS)

    Joseph, F Maria; Podder, T; Yu, Y

    2015-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is gradually becoming popular in treating patients with prostate cancers. However, placement of the HDR needles at desired locations into the patient is challenging. Application of robotic system may improve the accuracy of the clinical procedure. This experimental study is to evaluate the feasibility of using a multichannel robotic system for prostate HDR brachytherapy. Methods: In this experimental study, the robotic system employed was a 6-DOF Multichannel Image-guided Robotic Assistant for Brachytherapy (MIRAB), which was designed and fabricated for prostate seed implantation. The MIRAB has the provision of rotating 16 needles while inserting them. Ten prostate HDR brachytherapy needles were simultaneously inserted using MIRAB into a commercially available prostate phantom. After inserting the needles into the prostate phantom at desired locations, 2mm thick CT slices were obtained for dosimetric planning. HDR plan was generated using Oncetra planning system with a total prescription dose of 34Gy in 4 fractions. Plan quality was evaluated considering dose coverage to prostate and planning target volume (PTV), with 3mm margin around prostate, as well as the dose limit to the organs at risk (OARs) following the American Brachytherapy Society (ABS) guidelines. Results: From the CT scan, it is observed that the needles were inserted straight into the desired locations and they were adequately spaced and distributed for a clinically acceptable HDR plan. Coverage to PTV and prostate were about 91% (V100= 91%) and 96% (V100=96%), respectively. Dose to 1cc of urethra, rectum, and bladder were within the ABS specified limits. Conclusion: The MIRAB was able to insert multiple needles simultaneously into the prostate precisely. By controlling the MIRAB to insert all the ten utilized needles into the prostate phantom, we could achieve the robotic HDR brachytherapy successfully. Further study for assessing the system

  7. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    Energy Technology Data Exchange (ETDEWEB)

    Itatani, R., E-mail: banguliao@gmail.com [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Namimoto, T. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Atsuji, S.; Katahira, K.; Morishita, S. [Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitani, K.; Hamada, Y. [Department of Urology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitaoka, M. [Department of Pathology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Nakaura, T. [Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046 (Japan); Yamashita, Y. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan)

    2014-10-15

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy.

  8. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    International Nuclear Information System (INIS)

    Itatani, R.; Namimoto, T.; Atsuji, S.; Katahira, K.; Morishita, S.; Kitani, K.; Hamada, Y.; Kitaoka, M.; Nakaura, T.; Yamashita, Y.

    2014-01-01

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy

  9. Robotic radiotherapy for prostate cancer with CyberKnife

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Benezery, K.; Bondiau, P.Y.; Marcie, S.; Gerard, J.P.; Chamorey, E.

    2007-01-01

    After 3D conformal radiation therapy without and with modulated intensity, image-guided radiation therapy represents a new technological step. Should prostate cancer treatment using radiotherapy with the CyberKnife robotic system be considered as a new treatment and then investigated through classical clinical research procedure rather than a technical improvement of an already validated treatment? After a general presentation of the CyberKnife, the authors focused on prostate cancer treatment assuming that, according to dosimetric and biological considerations, the treatment by robotic system appears comparable to high dose rate brachytherapy. For prostate cancer treatment are discussed: biological rational for hypo fractionated treatment, high dose rate brachytherapy boost and interest of dose escalation. A comparison is presented between CyberKnife and other validated treatment for prostate cancer (radical prostatectomy, 3D conformal radiation therapy and low and high dose rate brachytherapy). In summary, CyberKnife treatment could be considered as a technical improvement of an already validated treatment in order to deliver a prostate boost after pelvic or peri-prostatic area irradiation. However, the clinical, biological and economical results must be precisely analyzed and could be assessed in the frame of a National Observatory based on shared therapeutic program. (authors)

  10. MRI diagnosis for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Tsutomu; Nagai, Kiyohisa; Imai, Shigeki; Kajihara, Yasumasa; Jo, Yoshimasa; Tanaka, Hiroyoshi; Fukunaga, Masao (Kawasaki Medical School, Kurashiki, Okayama (Japan)); Matsuki, Takakazu

    1998-01-01

    Recently, in Japan, both the Westernization of life styles and the advent of an aged-society have led to an increase in the incidence of prostate cancer. In making a localizing diagnosis of prostate cancer, magnetic resonance imaging (MRI), which has excellent contrast resolution, and transrectal ultrasonography, are used clinically, and their usefulness is being established. MRI is employed in the diagnosis of prostate cancer to detect tumors, and to determine the stage of such tumors. For the visualization of prostate cancer by MRI, T2-weighted axial images are used exclusively. After becoming familiar with normal prostate images, it is important to evaluate the localization of a tumor, and the invasion of the capsule and seminal vesicles. Future applications of new techniques for MRI will undoubtedly be found. In this paper, the present state of MRI diagnosis of prostate cancer at Kawasaki Medical School Hospital will be reviewed. (author)

  11. MRI diagnosis for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Tsutomu; Nagai, Kiyohisa; Imai, Shigeki; Kajihara, Yasumasa; Jo, Yoshimasa; Tanaka, Hiroyoshi; Fukunaga, Masao [Kawasaki Medical School, Kurashiki, Okayama (Japan); Matsuki, Takakazu

    1998-12-31

    Recently, in Japan, both the Westernization of life styles and the advent of an aged-society have led to an increase in the incidence of prostate cancer. In making a localizing diagnosis of prostate cancer, magnetic resonance imaging (MRI), which has excellent contrast resolution, and transrectal ultrasonography, are used clinically, and their usefulness is being established. MRI is employed in the diagnosis of prostate cancer to detect tumors, and to determine the stage of such tumors. For the visualization of prostate cancer by MRI, T2-weighted axial images are used exclusively. After becoming familiar with normal prostate images, it is important to evaluate the localization of a tumor, and the invasion of the capsule and seminal vesicles. Future applications of new techniques for MRI will undoubtedly be found. In this paper, the present state of MRI diagnosis of prostate cancer at Kawasaki Medical School Hospital will be reviewed. (author)

  12. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  13. MRI for troubleshooting detection of prostate cancer; MRT zur Problemloesung beim Nachweis des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Beyersdorff, D.; Hamm, B. [Universitaetsmedizin Berlin, Charite Mitte (Germany)

    2005-06-01

    Prostate cancer is the most common malignancy in males. Men aged 50 and older are recommended to undergo an annual digital rectal examination (DRE) and determination of prostate-specific antigen (PSA) in serum for early detection. However, prostate biopsies guided by transrectal ultrasound (TRUS) come up negative for cancer in many patients despite having PSA levels above 4 ng/ml. T2-weighted Magnetic Resonance Imaging (MRI) is able to represent the prostate including the surrounding anatomy and depict suspicious areas of low intensity within a high-intensity peripheral zone. MRI has a higher sensitivity for detecting prostate carcinomas than DRE and TRUS in patients having an elevated PSA value and a negative core biopsy. However, its specificity is poor since other abnormalities such as prostatic intraepithelial neoplasia (PIN), prostatitis, scars, or haemmorrhage have a similar MRI appearance. The use of additional techniques such as MR spectroscopy and contrast-enhanced dynamic MRI improves sensitivity, but in particular it improves the specificity of tumor detection. Newly developed biopsy devices enable the performance of targeted biopsies in areas that appear suspicious in the MRI. (orig.)

  14. Quantitative graphical analysis of simultaneous dynamic PET/MRI for assessment of prostate cancer.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Koesters, Thomas; Vahle, Anne-Kristin; Friedman, Kent; Bartlett, Rachel M; Taneja, Samir S; Ding, Yu-Shin; Logan, Jean

    2015-04-01

    Dynamic FDG imaging for prostate cancer characterization is limited by generally small size and low uptake in prostate tumors. Our aim in this pilot study was to explore feasibility of simultaneous PET/MRI to guide localization of prostate lesions for dynamic FDG analysis using a graphical approach. Three patients with biopsy-proven prostate cancer underwent simultaneous FDG PET/MRI, incorporating dynamic prostate imaging. Histology and multiparametric MRI findings were used to localize tumors, which in turn guided identification of tumors on FDG images. Regions of interest were manually placed on tumor and benign prostate tissue. Blood activity was extracted from a region of interest placed on the femoral artery on PET images. FDG data were analyzed by graphical analysis using the influx constant Ki (Patlak analysis) when FDG binding seemed irreversible and distribution volume VT (reversible graphical analysis) when FDG binding seemed reversible given the presence of washout. Given inherent coregistration, simultaneous acquisition facilitated use of MRI data to localize small lesions on PET and subsequent graphical analysis in all cases. In 2 cases with irreversible binding, tumor had higher Ki than benign using Patlak analysis (0.023 vs 0.006 and 0.019 vs 0.008 mL/cm3 per minute). In 1 case appearing reversible, tumor had higher VT than benign using reversible graphical analysis (0.68 vs 0.52 mL/cm3). Simultaneous PET/MRI allows localization of small prostate tumors for dynamic PET analysis. By taking advantage of inclusion of the femoral arteries in the FOV, we applied advanced PET data analysis methods beyond conventional static measures and without blood sampling.

  15. TU-CD-BRB-12: Radiogenomics of MRI-Guided Prostate Cancer Biopsy Habitats

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanova, R; Lynne, C; Abraham, S; Patel, M; Jorda, M; Kryvenko, O; Ishkanian, A; Abramowitz, M; Pollack, A [University of Miami, Miami, FL (United States); Tachar, M; Erho, N; Buerki, C; Lam, L; Davicioni, E [GenomeDx Biosciences Inc., Vancouver, British Columbia (Canada)

    2015-06-15

    Purpose: Diagnostic prostate biopsies are subject to sampling bias. We hypothesize that quantitative imaging with multiparametric (MP)-MRI can more accurately direct targeted biopsies to index lesions associated with highest risk clinical and genomic features. Methods: Regionally distinct prostate habitats were delineated on MP-MRI (T2-weighted, perfusion and diffusion imaging). Directed biopsies were performed on 17 habitats from 6 patients using MRI-ultrasound fusion. Biopsy location was characterized with 52 radiographic features. Transcriptome-wide analysis of 1.4 million RNA probes was performed on RNA from each habitat. Genomics features with insignificant expression values (<0.25) and interquartile range <0.5 were filtered, leaving total of 212 genes. Correlation between imaging features, genes and a 22 feature genomic classifier (GC), developed as a prognostic assay for metastasis after radical prostatectomy was investigated. Results: High quality genomic data was derived from 17 (100%) biopsies. Using the 212 ‘unbiased’ genes, the samples clustered by patient origin in unsupervised analysis. When only prostate cancer related genomic features were used, hierarchical clustering revealed samples clustered by needle-biopsy Gleason score (GS). Similarly, principal component analysis of the imaging features, found the primary source of variance segregated the samples into high (≥7) and low (6) GS. Pearson’s correlation analysis of genes with significant expression showed two main patterns of gene expression clustering prostate peripheral and transitional zone MRI features. Two-way hierarchical clustering of GC with radiomics features resulted in the expected groupings of high and low expressed genes in this metastasis signature. Conclusions: MP-MRI-targeted diagnostic biopsies can potentially improve risk stratification by directing pathological and genomic analysis to clinically significant index lesions. As determinant lesions are more reliably

  16. Evaluation of the ESUR PI-RADS scoring system for multiparametric MRI of the prostate with targeted MR/TRUS fusion-guided biopsy at 3.0 Tesla.

    Science.gov (United States)

    Roethke, M C; Kuru, T H; Schultze, S; Tichy, D; Kopp-Schneider, A; Fenchel, M; Schlemmer, H-P; Hadaschik, B A

    2014-02-01

    To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.

  17. Body-mounted robotic instrument guide for image-guided cryotherapy of renal cancer

    Science.gov (United States)

    Hata, Nobuhiko; Song, Sang-Eun; Olubiyi, Olutayo; Arimitsu, Yasumichi; Fujimoto, Kosuke; Kato, Takahisa; Tuncali, Kemal; Tani, Soichiro; Tokuda, Junichi

    2016-01-01

    Purpose: Image-guided cryotherapy of renal cancer is an emerging alternative to surgical nephrectomy, particularly for those who cannot sustain the physical burden of surgery. It is well known that the outcome of this therapy depends on the accurate placement of the cryotherapy probe. Therefore, a robotic instrument guide may help physicians aim the cryotherapy probe precisely to maximize the efficacy of the treatment and avoid damage to critical surrounding structures. The objective of this paper was to propose a robotic instrument guide for orienting cryotherapy probes in image-guided cryotherapy of renal cancers. The authors propose a body-mounted robotic guide that is expected to be less susceptible to guidance errors caused by the patient’s whole body motion. Methods: Keeping the device’s minimal footprint in mind, the authors developed and validated a body-mounted, robotic instrument guide that can maintain the geometrical relationship between the device and the patient’s body, even in the presence of the patient’s frequent body motions. The guide can orient the cryotherapy probe with the skin incision point as the remote-center-of-motion. The authors’ validation studies included an evaluation of the mechanical accuracy and position repeatability of the robotic instrument guide. The authors also performed a mock MRI-guided cryotherapy procedure with a phantom to compare the advantage of robotically assisted probe replacements over a free-hand approach, by introducing organ motions to investigate their effects on the accurate placement of the cryotherapy probe. Measurements collected for performance analysis included accuracy and time taken for probe placements. Multivariate analysis was performed to assess if either or both organ motion and the robotic guide impacted these measurements. Results: The mechanical accuracy and position repeatability of the probe placement using the robotic instrument guide were 0.3 and 0.1 mm, respectively, at a depth

  18. Clinical utility of an endorectal MRI-guided prostate probe: preliminary examinations

    Directory of Open Access Journals (Sweden)

    Tödter Julia

    2017-09-01

    Full Text Available Prostate cancer (PCa is one of the most common cancer diseases in men in the western countries [1]. Besides the palpation, and the amount of prostate-specific-antigen’s (PSA inside the blood, the current diagnostic imaging technologies are not appropriate. Early diagnosis defining the exact tumor location, spread and margins could make efficient targeted biopsies and image-guided surgery. A multimodal imaging technique containing a transmit-receive surface coil for anatomical MR imaging, a (SPET detector module, consisting of silicon photomultipliers (SiPM, for functional imaging and an ultrasound (US probe are placed as close as possible to the prostate designed as an endorectal tube to increase sensitivity and spatial resolution. All materials that are used are non-magnetic. Advantages of the SiPM are diversified, like non-sensitive to magnetic fields, higher gain (105–106 than standard avalanche photodiodes (APD, good timing properties and compactness. The PET detector should reach approximately 1mm3 spatial resolution together with 60ps FWHM Time-of-Flight resolution and a high efficiency to reduce scanning time and injected dose. A home-made transmit-receive coil surrounding the PET module improves signal-to-noise-ratio (SNR with respect to standard coils will be present. The system will be used as a MRI-insert and be able to visualize anatomic and metabolic information together. The US-probe is guiding examination for correct overlapping of the multimodal images. This procedure will save time, costs and the need of co-registration. By combining all advantages of each system, it will necessarily update the non-invasive treatment of PCa. The system is adapted and tested to a 3 Tesla MR scanner called Trio A Tim system and Allegra system from the company Siemens healthcare with a larmor frequency of 123.2 MHz and an input of 50 Ω free from artifacts. First results on homogeneity of the transmit-receive coil will be presented. Preliminary

  19. Multiparametric MRI of the anterior prostate gland: clinical–radiological–histopathological correlation

    International Nuclear Information System (INIS)

    Moosavi, B.; Flood, T.A.; Al-Dandan, O.; Breau, R.H.; Cagiannos, I.; Morash, C.; Malone, S.C.; Schieda, N.

    2016-01-01

    Anterior prostate cancer (APC) is defined as a tumour in which more than half of malignant tissue is located anterior to the urethra. APCs are increasingly recognized as clinically important, particularly in patients undergoing active surveillance and for patients with negative non-targeted systematic transrectal ultrasound (TRUS)-guided biopsies but with persistent clinical suspicion of cancer. Multiparametric (mp) MRI has a crucial role for the diagnosis of anterior tumours, eventual histological sampling of suspicious lesions using image-guided targeted biopsy techniques, and potentially, to improve local staging of disease. mpMRI is accurate for the detection of APC and for differentiation of tumour from other anterior prostatic structures including benign prostatic hyperplasia (BPH) and the anterior fibromuscular stroma (AFMS). Characterization and reporting of APC should rely on the recently revised Prostate Imaging and Data Reporting System (PI-RADS) version 2.0 document. T2-weighted (T2W) imaging is emphasized as the determining sequence for assessment of the anterior prostate and specific features for APC on T2W imaging include: ill-defined/spiculated margin, lenticular shape, anterior/inferior location, and growth pattern (invasion of urethra or AFMS and crossing midline). Functional imaging, mainly with diffusion-weighted imaging, is also contributory and improves the sensitivity for detection of APC compared to T2W imaging alone. APCs commonly show positive surgical margins after radical prostatectomy and staging of disease extent using conventional clinical parameters is limited. mpMRI may have a future role to improve local staging of APC. This review illustrates the importance of mpMRI in APC using a clinical–radiological–histopathological approach.

  20. Advances in MRI diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Zhang Longmin; Liu Ailian

    2014-01-01

    Prostate cancer is the second most common cancer in the world, and the incidence of prostate cancer in China shows an upward trend. MRI has high soft tissue resolution and multi-dimensional imaging advantages, and it can better show the anatomy of the prostate and adjacent tissue structures. With the development of MR technique, it plays a more and more important role in prostate cancer diagnosis. This review starts from the imaging performance of routine MRI sequence of prostate cancer, and a variety of functional MRI applications in the diagnosis and differential diagnosis of prostate cancer are described in detail, such as MR perfusion-weighted imaging, MR spectroscopy, MR diffusion-weighted imaging, MR diffusion tensor imaging, intravoxel incoherent motion diffusion-weighted imaging, MR susceptibility-weighted imaging. Meanwhile this review introduces that functional MRI has more advantages and can provide more image information than routine MRI sequence. According to a series of semi-quantitative and quantitative data, functional MRI can further provide the blood perfusion of prostate cancer, water molecule diffusion and microcirculation state, metabolism and biochemical composition change information. (authors)

  1. Thoughts turned into high-level commands: Proof-of-concept study of a vision-guided robot arm driven by functional MRI (fMRI) signals.

    Science.gov (United States)

    Minati, Ludovico; Nigri, Anna; Rosazza, Cristina; Bruzzone, Maria Grazia

    2012-06-01

    Previous studies have demonstrated the possibility of using functional MRI to control a robot arm through a brain-machine interface by directly coupling haemodynamic activity in the sensory-motor cortex to the position of two axes. Here, we extend this work by implementing interaction at a more abstract level, whereby imagined actions deliver structured commands to a robot arm guided by a machine vision system. Rather than extracting signals from a small number of pre-selected regions, the proposed system adaptively determines at individual level how to map representative brain areas to the input nodes of a classifier network. In this initial study, a median action recognition accuracy of 90% was attained on five volunteers performing a game consisting of collecting randomly positioned coloured pawns and placing them into cups. The "pawn" and "cup" instructions were imparted through four mental imaginery tasks, linked to robot arm actions by a state machine. With the current implementation in MatLab language the median action recognition time was 24.3s and the robot execution time was 17.7s. We demonstrate the notion of combining haemodynamic brain-machine interfacing with computer vision to implement interaction at the level of high-level commands rather than individual movements, which may find application in future fMRI approaches relevant to brain-lesioned patients, and provide source code supporting further work on larger command sets and real-time processing. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Optimising preoperative risk stratification tools for prostate cancer using mpMRI

    Energy Technology Data Exchange (ETDEWEB)

    Reisaeter, Lars A.R.; Losnegaard, Are; Biermann, Martin; Roervik, Jarle [Haukeland University Hospital, Department of Radiology, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway); Fuetterer, Jurgen J. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Nygaard, Yngve [Haukeland University Hospital, Department of Urology, Bergen (Norway); Monssen, Jan [Haukeland University Hospital, Department of Radiology, Bergen (Norway); Gravdal, Karsten [Haukeland University Hospital, Department of Pathology, Bergen (Norway); Halvorsen, Ole J.; Akslen, Lars A. [Haukeland University Hospital, Department of Pathology, Bergen (Norway); Centre for Cancer Biomarkers CCBIO, Department of Clinical Medicine, University of Bergen (Norway); Haukaas, Svein; Beisland, Christian [University of Bergen, Department of Clinical Medicine, Bergen (Norway); Haukeland University Hospital, Department of Urology, Bergen (Norway)

    2018-03-15

    To improve preoperative risk stratification for prostate cancer (PCa) by incorporating multiparametric MRI (mpMRI) features into risk stratification tools for PCa, CAPRA and D'Amico. 807 consecutive patients operated on by robot-assisted radical prostatectomy at our institution during the period 2010-2015 were followed to identify biochemical recurrence (BCR). 591 patients were eligible for final analysis. We employed stepwise backward likelihood methodology and penalised Cox cross-validation to identify the most significant predictors of BCR including mpMRI features. mpMRI features were then integrated into image-adjusted (IA) risk prediction models and the two risk prediction tools were then evaluated both with and without image adjustment using receiver operating characteristics, survival and decision curve analyses. 37 patients suffered BCR. Apparent diffusion coefficient (ADC) and radiological extraprostatic extension (rEPE) from mpMRI were both significant predictors of BCR. Both IA prediction models reallocated more than 20% of intermediate-risk patients to the low-risk group, reducing their estimated cumulative BCR risk from approximately 5% to 1.1%. Both IA models showed improved prognostic performance with a better separation of the survival curves. Integrating ADC and rEPE from mpMRI of the prostate into risk stratification tools improves preoperative risk estimation for BCR. (orig.)

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  4. The value of magnetic resonance imaging and ultrasonography (MRI/US)-fusion biopsy platforms in prostate cancer detection: a systematic review.

    Science.gov (United States)

    Gayet, Maudy; van der Aa, Anouk; Beerlage, Harrie P; Schrier, Bart Ph; Mulders, Peter F A; Wijkstra, Hessel

    2016-03-01

    Despite limitations considering the presence, staging and aggressiveness of prostate cancer, ultrasonography (US)-guided systematic biopsies (SBs) are still the 'gold standard' for the diagnosis of prostate cancer. Recently, promising results have been published for targeted prostate biopsies (TBs) using magnetic resonance imaging (MRI) and ultrasonography (MRI/US)-fusion platforms. Different platforms are USA Food and Drug Administration registered and have, mostly subjective, strengths and weaknesses. To our knowledge, no systematic review exists that objectively compares prostate cancer detection rates between the different platforms available. To assess the value of the different MRI/US-fusion platforms in prostate cancer detection, we compared platform-guided TB with SB, and other ways of MRI TB (cognitive fusion or in-bore MR fusion). We performed a systematic review of well-designed prospective randomised and non-randomised trials in the English language published between 1 January 2004 and 17 February 2015, using PubMed, Embase and Cochrane Library databases. Search terms included: 'prostate cancer', 'MR/ultrasound(US) fusion' and 'targeted biopsies'. Extraction of articles was performed by two authors (M.G. and A.A.) and were evaluated by the other authors. Randomised and non-randomised prospective clinical trials comparing TB using MRI/US-fusion platforms and SB, or other ways of TB (cognitive fusion or MR in-bore fusion) were included. In all, 11 of 1865 studies met the inclusion criteria, involving seven different fusion platforms and 2626 patients: 1119 biopsy naïve, 1433 with prior negative biopsy, 50 not mentioned (either biopsy naïve or with prior negative biopsy) and 24 on active surveillance (who were disregarded). The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to assess the quality of included articles. No clear advantage of MRI/US fusion-guided TBs was seen for cancer detection rates (CDRs) of all prostate

  5. 18F-DCFBC Prostate-Specific Membrane Antigen-Targeted PET/CT Imaging in Localized Prostate Cancer: Correlation With Multiparametric MRI and Histopathology.

    Science.gov (United States)

    Turkbey, Baris; Mena, Esther; Lindenberg, Liza; Adler, Stephen; Bednarova, Sandra; Berman, Rose; Ton, Anita T; McKinney, Yolanda; Eclarinal, Philip; Hill, Craig; Afari, George; Bhattacharyya, Sibaprasad; Mease, Ronnie C; Merino, Maria J; Jacobs, Paula M; Wood, Bradford J; Pinto, Peter A; Pomper, Martin G; Choyke, Peter L

    2017-10-01

    To assess the ability of (N-[N-[(S)-1,3-dicarboxypropyl]carbamoyl]-4-F-fluorobenzyl-L-cysteine) (F-DCFBC), a prostate-specific membrane antigen-targeted PET agent, to detect localized prostate cancer lesions in correlation with multiparametric MRI (mpMRI) and histopathology. This Health Insurance Portability and Accountability Act of 1996-compliant, prospective, institutional review board-approved study included 13 evaluable patients with localized prostate cancer (median age, 62.8 years [range, 51-74 years]; median prostate-specific antigen, 37.5 ng/dL [range, 3.26-216 ng/dL]). Patients underwent mpMRI and F-DCFBC PET/CT within a 3 months' window. Lesions seen on mpMRI were biopsied under transrectal ultrasound/MRI fusion-guided biopsy, or a radical prostatectomy was performed. F-DCFBC PET/CT and mpMRI were evaluated blinded and separately for tumor detection on a lesion basis. For PET image analysis, MRI and F-DCFBC PET images were fused by using software registration; imaging findings were correlated with histology, and uptake of F-DCFBC in tumors was compared with uptake in benign prostatic hyperplasia nodules and normal peripheral zone tissue using the 80% threshold SUVmax. A total of 25 tumor foci (mean size, 1.8 cm; median size, 1.5 cm; range, 0.6-4.7 cm) were histopathologically identified in 13 patients. Sensitivity rates of F-DCFBC PET/CT and mpMRI were 36% and 96%, respectively, for all tumors. For index lesions, the largest tumor with highest Gleason score, sensitivity rates of F-DCFBC PET/CT and mpMRI were 61.5% and 92%, respectively. The average SUVmax for primary prostate cancer was higher (5.8 ± 4.4) than that of benign prostatic hyperplasia nodules (2.1 ± 0.3) or that of normal prostate tissue (2.1 ± 0.4) at 1 hour postinjection (P = 0.0033). The majority of index prostate cancers are detected with F-DCFBC PET/CT, and this may be a prognostic indicator based on uptake and staging. However, for detecting prostate cancer with high sensitivity, it

  6. Modeling of the bony pelvis from MRI using a multi-atlas AE-SDM for registration and tracking in image-guided robotic prostatectomy.

    Science.gov (United States)

    Gao, Qinquan; Chang, Ping-Lin; Rueckert, Daniel; Ali, S Mohammed; Cohen, Daniel; Pratt, Philip; Mayer, Erik; Yang, Guang-Zhong; Darzi, Ara; Edwards, Philip Eddie

    2013-03-01

    A fundamental challenge in the development of image-guided surgical systems is alignment of the preoperative model to the operative view of the patient. This is achieved by finding corresponding structures in the preoperative scans and on the live surgical scene. In robot-assisted laparoscopic prostatectomy (RALP), the most readily visible structure is the bone of the pelvic rim. Magnetic resonance imaging (MRI) is the modality of choice for prostate cancer detection and staging, but extraction of bone from MRI is difficult and very time consuming to achieve manually. We present a robust and fully automated multi-atlas pipeline for bony pelvis segmentation from MRI, using a MRI appearance embedding statistical deformation model (AE-SDM). The statistical deformation model is built using the node positions of deformations obtained from hierarchical registrations of full pelvis CT images. For datasets with corresponding CT and MRI images, we can transform the MRI into CT SDM space. MRI appearance can then be used to improve the combined MRI/CT atlas to MRI registration using SDM constraints. We can use this model to segment the bony pelvis in a new MRI image where there is no CT available. A multi-atlas segmentation algorithm is introduced which incorporates MRI AE-SDMs guidance. We evaluated the method on 19 subjects with corresponding MRI and manually segmented CT datasets by performing a leave-one-out study. Several metrics are used to quantify the overlap between the automatic and manual segmentations. Compared to the manual gold standard segmentations, our robust segmentation method produced an average surface distance 1.24±0.27mm, which outperforms state-of-the-art algorithms for MRI bony pelvis segmentation. We also show that the resulting surface can be tracked in the endoscopic view in near real time using dense visual tracking methods. Results are presented on a simulation and a real clinical RALP case. Tracking is accurate to 0.13mm over 700 frames

  7. Practical aspects of MRI of the prostate

    Directory of Open Access Journals (Sweden)

    Dragoș Cuzino

    2014-12-01

    Full Text Available The article presents the main aspects of sectional anatomy, lymph nodes and adjacent structures as well as MRI examination standard protocol for prostate cancer diagnosis. Using MRI multiparametric examination we succeed in classifying efficiently the malignant prostatic tumors using PI- RADS system. Also, using MRI multiparametric examination we can evaluate the effectiveness of prostate cancer treatment

  8. Diffusion-weighted MRI of the prostate

    International Nuclear Information System (INIS)

    Mueller-Lisse, U.G.; Scherr, M.K.; Mueller-Lisse, U.L.; Zamecnik, P.; Schlemmer, H.P.W.

    2011-01-01

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [de

  9. Value of functional MRI in evaluation of patients with suspected prostate cancer

    Directory of Open Access Journals (Sweden)

    Mostafa Mohamed Mostafa Elian

    2015-12-01

    Conclusion: Functional MRI provided a highly sensitive method in diagnosing and localizing prostate cancer. Being noninvasive, highly sensitive with wider spectrum in nearby pelvic organs assessment in one imaging session, it may totally replace TRUS-guided biopsy.

  10. Image-robot coupling for the prostate brachytherapy

    International Nuclear Information System (INIS)

    Coelen, V.; Lartigau, E.; Merzouki, R.

    2009-01-01

    The results allows to contemplate a robot use in the prostate brachytherapy but equally in other applications such prostate biopsy. The tests to come are going to be directed towards on the use of a prostate phantom in order to calibrate the ultrasonography. thereafter, we contemplate the conception of an intelligent gripping system placed on the robot arm and allowing a good control in closed loop of the brachytherapy needle placement and allowing the setting up of an online monitoring. (N.C.)

  11. A MRI-CT prostate registration using sparse representation technique

    Science.gov (United States)

    Yang, Xiaofeng; Jani, Ashesh B.; Rossi, Peter J.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2016-03-01

    Purpose: To develop a new MRI-CT prostate registration using patch-based deformation prediction framework to improve MRI-guided prostate radiotherapy by incorporating multiparametric MRI into planning CT images. Methods: The main contribution is to estimate the deformation between prostate MRI and CT images in a patch-wise fashion by using the sparse representation technique. We assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. Specifically, there are two stages in our proposed framework, i.e., the training stage and the application stage. In the training stage, each prostate MR images are carefully registered to the corresponding CT images and all training MR and CT images are carefully registered to a selected CT template. Thus, we obtain the dense deformation field for each training MR and CT image. In the application stage, for registering a new subject MR image with the same subject CT image, we first select a small number of key points at the distinctive regions of this subject CT image. Then, for each key point in the subject CT image, we extract the image patch, centered at the underlying key point. Then, we adaptively construct the coupled dictionary for the underlying point where each atom in the dictionary consists of image patches and the respective deformations obtained from training pair-wise MRI-CT images. Next, the subject image patch can be sparsely represented by a linear combination of training image patches in the dictionary, where we apply the same sparse coefficients to the respective deformations in the dictionary to predict the deformation for the subject MR image patch. After we repeat the same procedure for each subject CT key point, we use B-splines to interpolate a dense deformation field, which is used as the initialization to allow the registration algorithm estimating the remaining small segment of deformations from MRI to CT image. Results: Our MRI-CT registration

  12. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2014-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0–10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation. PMID:25126153

  13. Prostate cancer: computer-aided diagnosis on multiparametric MRI

    Science.gov (United States)

    Marin, Laura; Racoceanu, Daniel; Renard Penna, Raphaele; Ezziane, Malek

    2017-11-01

    Prostate cancer (PCa) is one of the most common cancers in men, being also the second most deadly cancer after lung cancer. There is increasing interest in active surveillance and minimally invasive focal therapies in PCa to avoid morbidities associated with whole gland therapy. Tumor volume represents an essential prognostic factor of PCa and the definition of index lesion volume is critical for appropriate decision making, especially for image guide focal treatment or in case of active surveillance. Multi-parametric Magnetic Resonance Imaging (mp-MRI) is the modality of choice for the detection and the localization of PCa foci. However, little has been published on mp-MRI accuracy in determining PCa volume, especially at 3T. There is insufficient evidence and no consensus to determine which of the methods for measuring volume is optimal. The objective of this study concerns the elaboration of an algorithm for automatic interpretation of mp-MRI. We determine the accuracy of the proposed method by comparing the prostate tumor volume issued from the automated volumetric mp-MRI measurements of the tumoral region, with manual and semi-automated volumetric measurements done by and respectively with radiologists. Information issued from whole mount histopathology is used to validate the whole approach.

  14. Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

    Science.gov (United States)

    Tsekos, Nikolaos V; Khanicheh, Azadeh; Christoforou, Eftychios; Mavroidis, Constantinos

    2007-01-01

    The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.

  15. MRI of the prostate. Recommendations on patient preparation and scanning protocol; MRT der Prostata. Empfehlungen zur Vorbereitung und Durchfuehrung

    Energy Technology Data Exchange (ETDEWEB)

    Franiel, Tobias [University Hospital Jena (Germany). Dept. of Diagnostic and Interventional Radiology; Quentin, Michael; Schimmoeller, Lars [University Hospital Duesseldorf (Germany). Dept. of Diagnostic and Interventional Radiology; Mueller-Lisse, Ullrich Gerd [Munich Univ. (Germany). Dept. of Radiology; Asbach, Patrick [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Roedel, Stefan [Staedtisches Klinikum Dresden Friedrichstadt (Germany). Radiology; Willinek, Winfried [Bonn Univ. (Germany). Radiology; Hueper, Katja [Hannover Medical School (Germany). Inst. for Diagnostic and Interventional Radiology; Beyersdorff, Dirk [University Hospital Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Roethke, Matthias [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Radiology

    2017-01-15

    The Working Group Uroradiology and Urogenital Diagnosis of the German Roentgen Society has developed uniform recommendations for the preparation and implementation of prostate MRI. In the first part detailed recommendations are given in tabular form regarding 1. anamnestic data before prostate MRI, 2. termination of examinations and preparation of examinations, 3. examination protocol and 4. MRI-guided in-bore biopsy. In the second part, the recommendations are discussed in detail and relevant background information is provided.

  16. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  17. [Interest using 3D ultrasound and MRI fusion biopsy for prostate cancer detection].

    Science.gov (United States)

    Marien, A; De Castro Abreu, A; Gill, I; Villers, A; Ukimura, O

    2017-09-01

    The strategic therapy for prostate cancer depends on histo-pronostics data, which could be upgraded by obtaining targeted biopsies (TB) with MRI (magnetic resonance imagery) fusion 3D ultrasound. To compare diagnostic yield of image fusion guided prostate biopsy using image fusion of multi-parametric MRI (mpMRI) with 3D-TRUS. Between January 2010 and April 2013, 179 consecutive patients underwent outpatient TRUS biopsy using the real-time 3D TRUS tracking system (Urostation™). These patients underwent MRI-TRUS fusion targeted biopsies (TB) with 3D volume data of the MRI elastically fused with 3D TRUS at the time of biopsy. A hundred and seventy-three patients had TBs with fusion. Mean biopsy core per patient were 11.1 (6-14) for SB and 2.4 (1-6) for TB. SBs were positive in 11% compared to 56% for TB (Pperform the higher level of MR/US fusion and should be use for active surveillance. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. SU-E-J-232: Feasibility of MRI-Based Preplan On Low Dose Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Y; Tward, J; Rassiah-Szegedi, P; Zhao, H; Sarkar, V; Huang, L; Szegedi, M; Kokeny, K; Salter, B [University of Utah Huntsman Cancer Institute, Salt Lake City, UT (United States)

    2015-06-15

    Purpose: To investigate the feasibility of using MRI-based preplan for low dose rate prostate brachytherapy. Methods: 12 patients who received transrectal ultrasound (TRUS) guided prostate brachytherapy with Pd-103 were retrospectively studied. Our care-standard of the TRUS-based preplan served as the control. One or more prostate T2-weighted wide and/or narrow-field of view MRIs obtained within the 3 months prior to the implant were imported into the MIM Symphony software v6.3 (MIM Software Inc., Cleveland, OH) for each patient. In total, 37 MRI preplans (10 different image sequences with average thickness of 4.8mm) were generated. The contoured prostate volume and the seed counts required to achieve adequate dosimetric coverage from TRUS and MRI preplans were compared for each patient. The effects of different MRI sequences and image thicknesses were also investigated statistically using Student’s t-test. Lastly, the nomogram from the MRI preplan and TRUS preplan from our historical treatment data were compared. Results: The average prostate volume contoured on the TRUS and MRI were 26.6cc (range: 12.6∼41.3cc), and 27.4 cc (range: 14.3∼50.0cc), respectively. Axial MRI thicknesses (range: 3.5∼8.1mm) did not significantly affect the contoured volume or the number of seeds required on the preplan (R2 = 0.0002 and 0.0012, respectively). Four of the MRI sequences (AX-T2, AX-T2-Whole-Pelvis, AX-T2-FSE, and AXIALT2- Hi-Res) showed statistically significant better prostate volume agreement with TRUS than the other seven sequences (P <0.01). Nomogram overlay between the MRI and TRUS preplans showed good agreement; indicating volumes contoured on MRI preplan scan reliably predict how many seeds are needed for implant. Conclusion: Although MRI does not allow for determination of the actual implant geometry, it can give reliable volumes for seed ordering purposes. Our future work will investigate if MRI is sufficient to reliably replace TRUS preplanning in patients

  19. SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

    Energy Technology Data Exchange (ETDEWEB)

    Petronek, M; Purysko, A; Balik, S; Ciezki, J; Klein, E; Wilkinson, D [Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

  20. SU-F-T-42: MRI and TRUS Image Fusion as a Mode of Generating More Accurate Prostate Contours

    International Nuclear Information System (INIS)

    Petronek, M; Purysko, A; Balik, S; Ciezki, J; Klein, E; Wilkinson, D

    2016-01-01

    Purpose: Transrectal Ultrasound (TRUS) imaging is utilized intra-operatively for LDR permanent prostate seed implant treatment planning. Prostate contouring with TRUS can be challenging at the apex and base. This study attempts to improve accuracy of prostate contouring with MRI-TRUS fusion to prevent over- or under-estimation of the prostate volume. Methods: 14 patients with previous MRI guided prostate biopsy and undergone an LDR permanent prostate seed implant have been selected. The prostate was contoured on the MRI images (1 mm slice thickness) by a radiologist. The prostate was also contoured on TRUS images (5 mm slice thickness) during LDR procedure by a urologist. MRI and TRUS images were rigidly fused manually and the prostate contours from MRI and TRUS were compared using Dice similarity coefficient, percentage volume difference and length, height and width differences. Results: The prostate volume was overestimated by 8 ± 18% (range: 34% to −25%) in TRUS images compared to MRI. The mean Dice was 0.77 ± 0.09 (range: 0.53 to 0.88). The mean difference (TRUS-MRI) in the prostate width was 0 ± 4 mm (range: −11 to 5 mm), height was −3 ± 6 mm (range: −13 to 6 mm) and length was 6 ± 6 (range: −10 to 16 mm). Prostate was overestimated with TRUS imaging at the base for 6 cases (mean: 8 ± 4 mm and range: 5 to 14 mm), at the apex for 6 cases (mean: 11 ± 3 mm and range: 5 to 15 mm) and 1 case was underestimated at both base and apex by 4 mm. Conclusion: Use of intra-operative TRUS and MRI image fusion can help to improve the accuracy of prostate contouring by accurately accounting for prostate over- or under-estimations, especially at the base and apex. The mean amount of discrepancy is within a range that is significant for LDR sources.

  1. TH-CD-206-09: Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary

    International Nuclear Information System (INIS)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T

    2016-01-01

    Purpose: To enable MRI-guided prostate radiotherapy, MRI-CT deformable registration is required to map the MRI-defined tumor and key organ contours onto the CT images. Due to the intrinsic differences in grey-level intensity characteristics between MRI and CT images, the integration of MRI into CT-based radiotherapy is very challenging. We are developing a learning-based registration approach to address this technical challenge. Methods: We propose to estimate the deformation between MRI and CT images in a patch-wise fashion by using the sparse representation technique. Specifically, we assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. We first extract a set of key points in the new CT image. Then, for each key point, we adaptively construct a coupled dictionary from the training MRI-CT images, where each coupled element includes both appearance and deformation of the same image patch. After calculating the sparse coefficients in representing the patch appearance of each key point based on the constructed dictionary, we can predict the deformation for this point by applying the same sparse coefficients to the respective deformations in the dictionary. Results: This registration technique was validated with 10 prostate-cancer patients’ data and its performance was compared with the commonly used free-form-deformation-based registration. Several landmarks in both images were identified to evaluate the accuracy of our approach. Overall, the averaged target registration error of the intensity-based registration and the proposed method was 3.8±0.4 mm and 1.9±0.3 mm, respectively. Conclusion: We have developed a novel prostate MR-CT registration approach based on patch-deformation dictionary, demonstrated its clinical feasibility, and validated its accuracy. This technique will either reduce or compensate for the effect of patient-specific treatment variation measured during the course of

  2. TH-CD-206-09: Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X; Jani, A; Rossi, P; Mao, H; Curran, W; Liu, T [Emory University, Atlanta, GA (United States)

    2016-06-15

    Purpose: To enable MRI-guided prostate radiotherapy, MRI-CT deformable registration is required to map the MRI-defined tumor and key organ contours onto the CT images. Due to the intrinsic differences in grey-level intensity characteristics between MRI and CT images, the integration of MRI into CT-based radiotherapy is very challenging. We are developing a learning-based registration approach to address this technical challenge. Methods: We propose to estimate the deformation between MRI and CT images in a patch-wise fashion by using the sparse representation technique. Specifically, we assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. We first extract a set of key points in the new CT image. Then, for each key point, we adaptively construct a coupled dictionary from the training MRI-CT images, where each coupled element includes both appearance and deformation of the same image patch. After calculating the sparse coefficients in representing the patch appearance of each key point based on the constructed dictionary, we can predict the deformation for this point by applying the same sparse coefficients to the respective deformations in the dictionary. Results: This registration technique was validated with 10 prostate-cancer patients’ data and its performance was compared with the commonly used free-form-deformation-based registration. Several landmarks in both images were identified to evaluate the accuracy of our approach. Overall, the averaged target registration error of the intensity-based registration and the proposed method was 3.8±0.4 mm and 1.9±0.3 mm, respectively. Conclusion: We have developed a novel prostate MR-CT registration approach based on patch-deformation dictionary, demonstrated its clinical feasibility, and validated its accuracy. This technique will either reduce or compensate for the effect of patient-specific treatment variation measured during the course of

  3. Differentiation of prostate cancer from normal prostate tissue in an animal model: conventional MRI and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Gemeinhardt, O.; Prochnow, D.; Taupitz, M.; Hamm, B.; Beyersdorff, D.; Luedemann, L.; Abramjuk, C.

    2005-01-01

    Purpose: to differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. Material and methods: tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. Results: axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm3. In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420% (p<0.001) and 424% (p<0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. Conclusion: the results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model. (orig.)

  4. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier; Mathelin, Michel de; Jacqmin, Didier; Lang, Herve

    2012-01-01

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  5. Percutaneous MR-guided cryoablation of prostate cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Gangi, Afshin; Tsoumakidou, Georgia; Abdelli, Omar; Buy, Xavier [University Hospital of Strasbourg, Department of Interventional Radiology, Strasbourg (France); Mathelin, Michel de [University of Strasbourg, Lsiit, Strasbourg (France); Jacqmin, Didier; Lang, Herve [University Hospital of Strasbourg, Department of Urology, Strasbourg (France)

    2012-08-15

    We report our initial experience and the technical feasibility of transperineal prostate cryoablation under MR guidance. Percutaneous MR-guided cryoablation was performed in 11 patients with prostatic adenocarcinoma contraindicated for surgery (mean age: 72 years, mean Gleason score: 6.45, mean prostate-specific antigen (PSA): 6.21 ng/ml, T1-2c/N0/M0, mean: prostate volume 36.44 ml). Free-hand probe positioning was performed under real-time MR imaging. Four to seven cryoprobes were inserted into the prostate, depending on gland volume. The ice ball was monitored using real-time and high-resolution BLADE multi-planar imaging. Patients were followed at 1, 3, 6, 9 and 12 months after the procedure with serum PSA level and post-ablation MRI. Prostate cryoablation was technically feasible in 10/11 patients. The ice ball was clearly and sharply visualised in all cases as a signal-void area. Mean ice-ball volume was 53.3 ml. Mean follow-up was 15 months (range: 1-25). Mean PSA nadir was 0.33 ng/ml (range: 0.02-0.94 ng/ml). Mean hospitalisation was 5 days (range: 3-13). Complications included a urethro-rectal fistula, urinary infection, transient dysuria and scrotal pain. MR-guided prostate cryoablation is feasible and promising, with excellent monitoring of the ice ball. Future perspectives could include the use of MR guidance for focal prostate cancer cryotherapy. (orig.)

  6. Robotic simple prostatectomy: A consideration for large prostate adenomas

    Directory of Open Access Journals (Sweden)

    Joshua B. Nething

    2014-12-01

    Full Text Available Background: The management of benign prostatic hyperplasia (BPH has changed considerably over the last several decades. First line treatment of BPH and lower urinary tract symptoms (LUTS with medical therapy has created a population of men with much larger prostate glands, many of whom require surgical intervention. Patients with prostate glands greater than 80 to 100 grams may be better managed surgically with a retropubic prostatectomy. We explore our experience with robotic assisted simple prostatectomy and review the relevant literature. Database: The database reviewed includes our experience with seven patients undergoing robotic simple prostatectomy, and a comprehensive review of the previously published series of this procedure. In addition, the literature pertaining to a pure laparoscopic approach to simple prostatectomy is reviewed. Conclusion: Robotic experience and training has become a standard in resident training programs; while classic transurethral resection is being performed less for large prostate glands. The robotic approach to simple prostatectomy provides an excellent option for surgical treatment of very large prostate glands, providing patients acceptable results in terms of operative time, estimated blood loss, hospital stay and duration of Foley catheter.

  7. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  8. Mechanical Validation of an MRI Compatible Stereotactic Neurosurgery Robot in Preparation for Pre-Clinical Trials

    Science.gov (United States)

    Nycz, Christopher J; Gondokaryono, Radian; Carvalho, Paulo; Patel, Nirav; Wartenberg, Marek; Pilitsis, Julie G; Fischer, Gregory S

    2018-01-01

    The use of magnetic resonance imaging (MRI) for guiding robotic surgical devices has shown great potential for performing precisely targeted and controlled interventions. To fully realize these benefits, devices must work safely within the tight confines of the MRI bore without negatively impacting image quality. Here we expand on previous work exploring MRI guided robots for neural interventions by presenting the mechanical design and assessment of a device for positioning, orienting, and inserting an interstitial ultrasound-based ablation probe. From our previous work we have added a 2 degree of freedom (DOF) needle driver for use with the aforementioned probe, revised the mechanical design to improve strength and function, and performed an evaluation of the mechanism’s accuracy and effect on MR image quality. The result of this work is a 7-DOF MRI robot capable of positioning a needle tip and orienting it’s axis with accuracy of 1.37 ± 0.06mm and 0.79° ± 0.41°, inserting it along it’s axis with an accuracy of 0.06 ± 0.07mm, and rotating it about it’s axis to an accuracy of 0.77° ± 1.31°. This was accomplished with no significant reduction in SNR caused by the robot’s presence in the MRI bore, ≤ 10.3% reduction in SNR from running the robot’s motors during a scan, and no visible paramagnetic artifacts. PMID:29696097

  9. Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Sakurai, Kota; Nakano, Masahiro; Maeda, Sunaho; Kajita, Kimihiro R.T.; Deguchi, Takashi; Hoshi, Hiroaki

    2006-01-01

    Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 ± 6.17 cc (mean ± SD) in MRI-based dosimetry, and 15.97 ± 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported

  10. Effect of Prostate Magnetic Resonance Imaging/Ultrasound Fusion-guided Biopsy on Radiation Treatment Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Aaron; Valle, Luca F.; Shankavaram, Uma; Krauze, Andra; Kaushal, Aradhana; Schott, Erica; Cooley-Zgela, Theresa [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Wood, Bradford [Center for Interventional Oncology, National Institutes of Health, Bethesda, Maryland (United States); Pinto, Peter [Urologic Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Choyke, Peter; Turkbey, Baris [Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Citrin, Deborah E., E-mail: citrind@mail.nih.gov [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States)

    2017-04-01

    Purpose: Targeted magnetic resonance imaging (MRI)/ultrasound fusion prostate biopsy (MRI-Bx) has recently been compared with the standard of care extended sextant ultrasound-guided prostate biopsy (SOC-Bx), with the former associated with an increased rate of detection of clinically significant prostate cancer. The present study sought to determine the influence of MRI-Bx on radiation therapy and androgen deprivation therapy (ADT) recommendations. Methods and Materials: All patients who had received radiation treatment and had undergone SOC-Bx and MRI-Bx at our institution were included. Using the clinical T stage, pretreatment prostate-specific antigen, and Gleason score, patients were categorized into National Comprehensive Cancer Network risk groups and radiation treatment or ADT recommendations assigned. Intensification of the recommended treatment after multiparametric MRI, SOC-Bx, and MRI-Bx was evaluated. Results: From January 2008 to January 2016, 73 patients received radiation therapy at our institution after undergoing a simultaneous SOC-Bx and MRI-Bx (n=47 with previous SOC-Bx). Repeat SOC-Bx and MRI-Bx resulted in frequent upgrading compared with previous SOC-Bx (Gleason score 7, 6.7% vs 44.6%; P<.001; Gleason score 8-10, 2.1% vs 38%; P<.001). MRI-Bx increased the proportion of patients classified as very high risk from 24.7% to 41.1% (P=.027). Compared with SOC-Bx alone, including the MRI-Bx findings resulted in a greater percentage of pathologically positive cores (mean 37% vs 44%). Incorporation of multiparametric MRI and MRI-Bx results increased the recommended use and duration of ADT (duration increased in 28 of 73 patients and ADT was added for 8 of 73 patients). Conclusions: In patients referred for radiation treatment, MRI-Bx resulted in an increase in the percentage of positive cores, Gleason score, and risk grouping. The benefit of treatment intensification in accordance with the MRI-Bx findings is unknown.

  11. Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 Tesla for localizing prostate cancer: correlation with whole-mount histopathology.

    Science.gov (United States)

    Turkbey, Baris; Merino, Maria J; Gallardo, Elma Carvajal; Shah, Vijay; Aras, Omer; Bernardo, Marcelino; Mena, Esther; Daar, Dagane; Rastinehad, Ardeshir R; Linehan, W Marston; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L

    2014-06-01

    To compare utility of T2-weighted (T2W) MRI and diffusion-weighted MRI (DWI-MRI) obtained with and without an endorectal coil at 3 Tesla (T) for localizing prostate cancer. This Institutional Review Board-approved study included 20 patients (median prostate-specific antigen, 8.4 ng/mL). Patients underwent consecutive prostate MRIs at 3T, first with a surface coil alone, then with combination of surface, endorectal coils (dual coil) followed by robotic assisted radical prostatectomy. Lesions were mapped at time of acquisition on dual-coil T2W, DWI-MRI. To avoid bias, 6 months later nonendorectal coil T2W, DWI-MRI were mapped. Both MRI evaluations were performed by two readers blinded to pathology with differences resolved by consensus. A lesion-based correlation with whole-mount histopathology was performed. At histopathology 51 cancer foci were present ranging in size from 2 to 60 mm. The sensitivity of the endorectal dual-coil, nonendorectal coil MRIs were 0.76, 0.45, respectively. PPVs for endorectal dual-coil, nonendorectal coil MRI were 0.80, 0.64, respectively. Mean size of detected lesions with nonendorectal coil MRI were larger than those detected by dual-coil MRI (22 mm versus 17.4 mm). Dual-coil prostate MRI detected more cancer foci than nonendorectal coil MRI. While nonendorectal coil MRI is an attractive alternative, physicians performing prostate MRI should be aware of its limitations. Copyright © 2013 Wiley Periodicals, Inc.

  12. Multiparametric prostate MRI for follow-up monitoring after radiation therapy

    International Nuclear Information System (INIS)

    Weidner, A.M.; Dinter, D.J.; Bohrer, M.; Sertdemir, M.; Hausmann, D.; Wenz, F.; Schoenberg, S.O.

    2012-01-01

    Radiation therapy is a therapeutic option with curative intent for patients with prostate cancer. Monitoring of prostate-specific antigen (PSA) values is the current standard of care in the follow-up. Imaging is recommended only for symptomatic patients and/or for further therapeutic options. For detection of local recurrence magnetic resonance imaging (MRI) of the prostate is acknowledged as the method of choice. Good results for primary diagnosis were found especially in combination with functional techniques, whereas in recurrent prostate cancer only few studies with heterogeneous study design are available for prostate MRI. Furthermore, changes in different MRI modalities due to radiation therapy have been insufficiently investigated to date. As the initial results were promising prostate MRI and available therapeutic options for detection of local recurrence should be considered in patients with increased PSA. (orig.) [de

  13. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  14. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  15. PSNet: prostate segmentation on MRI based on a convolutional neural network.

    Science.gov (United States)

    Tian, Zhiqiang; Liu, Lizhi; Zhang, Zhenfeng; Fei, Baowei

    2018-04-01

    Automatic segmentation of the prostate on magnetic resonance images (MRI) has many applications in prostate cancer diagnosis and therapy. We proposed a deep fully convolutional neural network (CNN) to segment the prostate automatically. Our deep CNN model is trained end-to-end in a single learning stage, which uses prostate MRI and the corresponding ground truths as inputs. The learned CNN model can be used to make an inference for pixel-wise segmentation. Experiments were performed on three data sets, which contain prostate MRI of 140 patients. The proposed CNN model of prostate segmentation (PSNet) obtained a mean Dice similarity coefficient of [Formula: see text] as compared to the manually labeled ground truth. Experimental results show that the proposed model could yield satisfactory segmentation of the prostate on MRI.

  16. Robotic Radiosurgery. Treating prostata cancer and related genitourinary applications

    International Nuclear Information System (INIS)

    Ponsky, Lee E.

    2012-01-01

    Prostate cancer is the most common cancer among North American and European men, but its treatment continues to be problematic owing to serious side-effects, including erectile dysfunction, urinary incontinence, and potential lower GI complications. Robotic radiosurgery offers a novel, rapid, non-invasive outpatient treatment option for prostate cancer that combines robotics, advanced image-guided motion detection, and automated real-time corrective spatial positioning with submillimeter precision. This book examines all aspects of the treatment of prostate cancer with robotic radiosurgery. After introductory sections on radiosurgery as a multidisciplinary practice and specific issues relating to prostate cancer, the important challenge posed by prostate motion when administering radiation therapy is examined in depth, with detailed discussion as to how image-guided robotic radiosurgery overcomes this problem by continously identifying the precise location of the prostate throughout the course of treatment. A further major section is devoted to a discussion of techniques and potential radiobiological and clinical advantages of hypofractionated radiation delivery by means of robotic radiosurgery systems. The book closes by discussing other emerging genitourinary applications of robotic radiosurgery. All of the authors are experts in their field who present a persuasive case for this fascinating technique. (orig.)

  17. Robotic Radiosurgery. Treating prostata cancer and related genitourinary applications

    Energy Technology Data Exchange (ETDEWEB)

    Ponsky, Lee E. (ed.) [Case Western Reserve University School of Medicine, Cleveland, OH (United States). University Hospitals Case Medical Center

    2012-07-01

    Prostate cancer is the most common cancer among North American and European men, but its treatment continues to be problematic owing to serious side-effects, including erectile dysfunction, urinary incontinence, and potential lower GI complications. Robotic radiosurgery offers a novel, rapid, non-invasive outpatient treatment option for prostate cancer that combines robotics, advanced image-guided motion detection, and automated real-time corrective spatial positioning with submillimeter precision. This book examines all aspects of the treatment of prostate cancer with robotic radiosurgery. After introductory sections on radiosurgery as a multidisciplinary practice and specific issues relating to prostate cancer, the important challenge posed by prostate motion when administering radiation therapy is examined in depth, with detailed discussion as to how image-guided robotic radiosurgery overcomes this problem by continously identifying the precise location of the prostate throughout the course of treatment. A further major section is devoted to a discussion of techniques and potential radiobiological and clinical advantages of hypofractionated radiation delivery by means of robotic radiosurgery systems. The book closes by discussing other emerging genitourinary applications of robotic radiosurgery. All of the authors are experts in their field who present a persuasive case for this fascinating technique. (orig.)

  18. 3D Registration of mpMRI for Assessment of Prostate Cancer Focal Therapy.

    Science.gov (United States)

    Orczyk, Clément; Rosenkrantz, Andrew B; Mikheev, Artem; Villers, Arnauld; Bernaudin, Myriam; Taneja, Samir S; Valable, Samuel; Rusinek, Henry

    2017-12-01

    This study aimed to assess a novel method of three-dimensional (3D) co-registration of prostate magnetic resonance imaging (MRI) examinations performed before and after prostate cancer focal therapy. We developed a software platform for automatic 3D deformable co-registration of prostate MRI at different time points and applied this method to 10 patients who underwent focal ablative therapy. MRI examinations were performed preoperatively, as well as 1 week and 6 months post treatment. Rigid registration served as reference for assessing co-registration accuracy and precision. Segmentation of preoperative and postoperative prostate revealed a significant postoperative volume decrease of the gland that averaged 6.49 cc (P = .017). Applying deformable transformation based on mutual information from 120 pairs of MRI slices, we refined by 2.9 mm (max. 6.25 mm) the alignment of the ablation zone, segmented from contrast-enhanced images on the 1-week postoperative examination, to the 6-month postoperative T2-weighted images. This represented a 500% improvement over the rigid approach (P = .001), corrected by volume. The dissimilarity by Dice index of the mapped ablation zone using deformable transformation vs rigid control was significantly (P = .04) higher at the ablation site than in the whole gland. Our findings illustrate our method's ability to correct for deformation at the ablation site. The preliminary analysis suggests that deformable transformation computed from mutual information of preoperative and follow-up MRI is accurate in co-registration of MRI examinations performed before and after focal therapy. The ability to localize the previously ablated tissue in 3D space may improve targeting for image-guided follow-up biopsy within focal therapy protocols. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Improved detection of localized prostate cancer using co-registered MRI and {sup 11}C-acetate PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Jambor, Ivan, E-mail: ivjamb@utu.fi [Department of Diagnostic Radiology, University of Turku, Turku (Finland); 2nd Department of Radiology, Comenius University and St. Elisabeth Oncology Institute, Bratislava (Slovakia); Turku PET Centre, University of Turku, Turku (Finland); Borra, Ronald, E-mail: ronald.borra@tyks.fi [Department of Diagnostic Radiology, University of Turku, Turku (Finland); Turku PET Centre, University of Turku, Turku (Finland); Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku (Finland); Kemppainen, Jukka, E-mail: Jukka.Kemppainen@tyks.fi [Turku PET Centre, University of Turku, Turku (Finland); Department of Clinical Physiology and Nuclear Medicine, Turku University Hospital, Turku (Finland); Lepomaeki, Virva, E-mail: Virva.Lepomaki@tyks.fi [Turku PET Centre, University of Turku, Turku (Finland); Parkkola, Riitta, E-mail: Riitta.Parkkola@tyks.fi [Department of Diagnostic Radiology, University of Turku, Turku (Finland); Turku PET Centre, University of Turku, Turku (Finland); Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku (Finland); Dean, Kirsti, E-mail: Kirsti.Dean@tyks.fi [Department of Diagnostic Radiology, University of Turku, Turku (Finland); Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku (Finland); Alanen, Kalle, E-mail: Kalle.Alanen@tyks.fi [Department of Pathology, Turku University Hospital, Turku (Finland); Arponen, Eveliina, E-mail: Eveliina.Arponen@utu.fi [Turku PET Centre, University of Turku, Turku (Finland); Nurmi, Martti, E-mail: Martti.Nurmi@tyks.fi [Department of Surgery, Division of Urology, Turku University Hospital, Turku (Finland); Aronen, Hannu J., E-mail: Hannu.Aronen@tyks.fi [Department of Diagnostic Radiology, University of Turku, Turku (Finland); Medical Imaging Centre of Southwest Finland, Turku University Hospital, Turku (Finland); and others

    2012-11-15

    Objectives: We aimed to study the ability of contrast enhanced MRI at 1.5 T and {sup 11}C-acetate PET/CT, both individually and using fused data, to detect localized prostate cancer. Methods: Thirty-six men with untreated prostate cancer and negative for metastatic disease on pelvic CT and bone scan were prospectively enrolled. A pelvic {sup 11}C-acetate PET/CT scan was performed in all patients, and a contrast enhanced MRI scan in 33 patients (6 examinations using both endorectal coil and surface coils, and 27 examinations using surface coils only). After the imaging studies 10 patients underwent prostatectomy and 26 were treated by image guided external beam radiation treatment. Image fusion of co-registered PET and MRI data was performed based on anatomical landmarks visible on CT and MRI using an advanced in-house developed software package. PET/CT, MRI and fused PET/MRI data were evaluated visually and compared with biopsy findings on a lobar level, while a sextant approach was used for patients undergoing prostatectomy. Results: When using biopsy samples as method of reference, the sensitivity, specificity and accuracy for visual detection of prostate cancer on a lobar level by contrast enhanced MRI was 85%, 37%, 73% and that of {sup 11}C-acetate PET/CT 88%, 41%, 74%, respectively. Fusion of PET with MRI data increased sensitivity, specificity and accuracy to 90%, 72% and 85%, respectively. Conclusions: Fusion of sequentially obtained PET/CT and MRI data for the localization of prostate cancer is feasible and superior to the performance of each individual modality alone.

  20. The CI-ROB project: real time monitoring for a robotic prostate curietherapy

    International Nuclear Information System (INIS)

    Liem, X.; Lartigau, E.; Coelen, V.; Merzouki, R.

    2010-01-01

    The authors present a project which is still at the proto-typing stage and for which hardware and software are still being developed, and which aims at developing a full line for a robotic curietherapy. It comprises an articulated robotic arm with six degree of freedom, and is based on an auto-regulated loop with real time monitoring and control. An echographic probe acquires the prostate images in real time. An adaptive detection defines the prostate contour. This is performed in a virtual environment which comprises the prostate phantom, the robot and the intervention table. The target is defined in the virtual environment (image coordinates) and coordinates are transmitted to the robot controller which defines the robot movements by using the inverse geometric model. Short communication

  1. Prostate cancer diagnosis: Efficacy of a simple electromagnetic MRI-TRUS fusion method to target biopsies

    International Nuclear Information System (INIS)

    Jelidi, Amina; Ohana, Mickael; Labani, Aïssam; Alemann, Guillaume; Lang, Herve; Roy, Catherine

    2017-01-01

    Highlights: • A very simple electromagnetic device for fusion with MRI examination during TRUS guided biopsies increases the detection of clinically significant prostate cancer. • This device has advantages: a short time for the fusion registration, no additional cumbersome material and no intense training to be fluent with. • Low or intermediate suspicious area for prostate carcinoma on mpMRI can be due to benign histological abnormalities or high grade prostatic intraepithelial neoplasia. - Abstract: Objective: To assess that transrectal ultrasound guidance (TRUS) targeted biopsies (TB) aimed with an easy to use electronic real-time fusion registration device have a higher rate of prostate cancer (PC) detection than standard biopsies (SB). Material and methods: This prospective study included 130 patients referred for TRUS biopsies after suspicious MRI. They underwent 16-core SB and 2 to 3 cores in each MRI suspicious area, using a fusion software. We noted SB and TB positivity for PC and Gleason score (GS). We used the McNemar test to compare SB and TB, with a statistical significance p < 0.05. Results: Among 130 patients, 68.5% had PC. Additional time due to the fusion registration was 3.3 min. One hundred fifteen patients (88.4%) had pathological findings on the histological analysis (prostate cancer n = 89, others n = 26). TB diagnosed PC in 75 patients with negative SB. Positivity rate for PC was significantly higher for TB than SB (p = 0.03). Among highly suspicious MRI lesions, detection rate of histological abnormalities using SB and TB was 96% with 79.7% of PC. Most PC that TB diagnosed alone were clinically significant (86.3%). Conclusion: TRUS biopsies performed with a simple MRI and US electronic fusion is an unrestrainedly method to increase PC diagnosis.

  2. Prostatic intraepithelial neoplasia-like ductal prostatic adenocarcinoma: A case suitable for active surveillance?

    Directory of Open Access Journals (Sweden)

    Soroush Rais-Bahrami

    2017-01-01

    Full Text Available In contrast to typical prostatic ductal adenocarcinoma, prostatic intraepithelial neoplasia (PIN-like ductal adenocarcinoma is a rare variant of prostate cancer with low-grade clinical behavior. We report a case of a 66-year-old African-American male with an elevated serum prostate-specific antigen who underwent multiparametric prostate magnetic resonance imaging (MRI and MRI/ultrasound fusion-guided biopsies. Pathology demonstrated low-volume Gleason score 3 + 3 = 6 (Grade Group 1, acinar adenocarcinoma involving one core and PIN-like ductal adenocarcinoma on a separate core. Herein, we discuss the potential role of active surveillance for patients with this rare variant of prostate cancer found in the era of advanced imaging with multiparametric MRI for prostate cancer.

  3. SU-G-JeP2-14: MRI-Based HDR Prostate Brachytherapy: A Phantom Study for Interstitial Catheter Reconstruction with 0.35T MRI Images

    International Nuclear Information System (INIS)

    Park, S; Kamrava, M; Yang, Y

    2016-01-01

    Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI was acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.

  4. Multiparametric MRI of the prostate. Method for early detection of prostate cancer?

    International Nuclear Information System (INIS)

    Schlemmer, Heinz-Peter

    2010-01-01

    Current approaches for the early detection of prostate cancer are controversially discussed because the disease is characterized by a high incidence rate with a relatively low morbidity rate, availability of only limited prognostic markers, and continued therapy-related morbidity. Conventional morphological MRI does not play a role in early detection since small tumor foci cannot be delineated. However, if there is clinical suspicion for prostate cancer, multiparametric MRI is currently the most accurate method for detecting and characterizing suspicious lesions in the prostate. The potential to identify the so-called 'index lesion', i.e., the tumor area that is most aggressive and determines treatment, is particularly important. This information can increase the accuracy of prostate biopsy and serve as a biomarker for follow-up during active surveillance. The method may considerably contribute to the urgently required separation of clinically significant from clinically insignificant prostate cancers. (orig.)

  5. Dynamic contrast enhanced MRI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alonzi, Roberto [Marie Curie Research Wing, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom)], E-mail: robertoalonzi@btinternet.com; Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom); Synarc Inc. 575 Market Street, San Francisco, CA 94105 (United States)], E-mail: anwar.padhani@paulstrickland-scannercentre.org.uk; Allen, Clare [Department of Imaging, University College Hospital, London, 235 Euston Road, NW1 2BU (United Kingdom)], E-mail: clare.allen@uclh.nhs.uk

    2007-09-15

    Angiogenesis is an integral part of benign prostatic hyperplasia (BPH), is associated with prostatic intraepithelial neoplasia (PIN) and is key to the growth and for metastasis of prostate cancer. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) using small molecular weight gadolinium chelates enables non-invasive imaging characterization of tissue vascularity. Depending on the technique used, data reflecting tissue perfusion, microvessel permeability surface area product, and extracellular leakage space can be obtained. Two dynamic MRI techniques (T{sub 2}*-weighted or susceptibility based and T{sub 1}-weighted or relaxivity enhanced methods) for prostate gland evaluations are discussed in this review with reference to biological basis of observations, data acquisition and analysis methods, technical limitations and validation. Established clinical roles of T{sub 1}-weighted imaging evaluations will be discussed including lesion detection and localisation, for tumour staging and for the detection of suspected tumour recurrence. Limitations include inadequate lesion characterisation particularly differentiating prostatitis from cancer, and in distinguishing between BPH and central gland tumours.

  6. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  7. An integrated multimodality image-guided robot system for small-animal imaging research

    International Nuclear Information System (INIS)

    Hsu, Wen-Lin; Hsin Wu, Tung; Hsu, Shih-Ming; Chen, Chia-Lin; Lee, Jason J.S.; Huang, Yung-Hui

    2011-01-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO 2 probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153±0.042 mm of desired placement; the phantom simulation errors were within 0.693±0.128 mm. In small-animal studies, the pO 2 probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  8. Multiparametric MRI of the prostate. Important radiological findings for urologists; Multiparametrische MRT der Prostata. Wichtige radiologische Befunde fuer den Urologen

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany)

    2017-08-15

    High prevalence of prostate cancer with multifocality and biological heterogeneity. Insufficient conventional urological diagnostics. Discrimination between significant and insignificant cancer needed. Digital rectal examination, prostate-specific antigen (PSA) serum level, systematic transrectal ultrasound (TRUS)-guided prostate biopsy. Multiparametric magnetic resonance imaging (mpMRI) including T2-weighted (T2w), diffusion-weighted and dynamic contrast-enhanced MRI according to the prostate imaging reporting and data system (PIRADS), MR-targeted biopsy, most frequently MR/TRUS image fusion biopsy. Prostate cancer is characterized by low signal intensity on T2w MRI, restricted water diffusion and pronounced and early uptake of contrast enhancement. Sensitivity and specificity according to the current literature are ca. 80% and 90%, respectively. In cases of suspected prostate cancer, most accurate are mpMRI according to PIRADS and in cases of positive findings, MRI-targeted biopsy, most frequently as MRI/TRUS image fusion biopsy. (orig.) [German] Hohe Praevalenz des Prostatakarzinoms mit Multifokalitaet und biologischer Heterogenitaet. Unzureichende konventionelle urologische Diagnostik. Unterscheidung klinisch signifikanter von klinisch nicht signifikanten Karzinomen erforderlich. Digitale rektale Untersuchung, Serum-PSA (prostataspezifisches Antigen), transrektale Sonographie (TRUS), systematische transrektale TRUS-Biopsie. Multiparametrische Magnetresonanztomographie (mpMRT) mit T2w- und diffusionsgewichteten sowie dynamischen kontrastmittelverstaerkten T1w-Sequenzen, dem Standard nach dem Prostate Imaging Reporting and Data System (PIRADS) entsprechend. MR-unterstuetzte Biopsie, meist MR-/TRUS-Fusionsbiopsie. Prostatakarzinome sind typischerweise T2-hypointens mit eingeschraenkter Diffusion und zeigen eine rasche Kontrastmittelanflutung. Nach der Literatur betragen Sensitivitaet und Spezifitaet der mpMRT ca. 80 bzw. 90 %. Fuer die Abklaerung bei Verdacht auf

  9. PI-RADS classification. Structured reporting for MRI of the prostate

    International Nuclear Information System (INIS)

    Roethke, Matthias; Schlemmer, H.P.; Blondin, D.; Franiel, T.

    2013-01-01

    Purpose: To flesh out the ESUR guidelines for the standardized interpretation of multiparametric magnetic resonance imaging (mMRI) for the detection of prostate cancer and to present a graphic reporting scheme for improved communication of findings to urologists. Materials and Methods: The ESUR has recently published a structured reporting system for mMRI of the prostate (PI-RADS). This system involves the use of 5-point Likert scales for grading the findings obtained with different MRI techniques. The mMRI includes T2-weighted MRI, diffusion-weighted imaging, dynamic contrast-enhanced MRI, and MR spectroscopy. In a first step, the fundamentals of technical implementation were determined by consensus, taking into account in particular the German-speaking community. Then, representative images were selected by consensus on the basis of examinations of the three institutions. In addition, scoring intervals for an aggregated PI-RADS score were determined in consensus. Results: The multiparametric methods were discussed critically with regard to implementation and the current status. Criteria used for grading mMRI findings with the PI-RADS classification were concretized by succinct examples. Using the consensus table for aggregated scoring in a clinical setting, a diagnosis of suspected prostate cancer should be made if the PI-RADS score is 4 or higher (≥ 10 points if 3 techniques are used or ≥ 13 points if 4 techniques are used). Finally, a graphic scheme was developed for communicating mMRI prostate findings. Conclusion: Structured reporting according to the ESUR guidelines contributes to quality assurance by standardizing prostate mMRI, and it facilities the communication of findings to urologists. (orig.)

  10. Experientally guided robots. [for planet exploration

    Science.gov (United States)

    Merriam, E. W.; Becker, J. D.

    1974-01-01

    This paper argues that an experientally guided robot is necessary to successfully explore far-away planets. Such a robot is characterized as having sense organs which receive sensory information from its environment and motor systems which allow it to interact with that environment. The sensori-motor information which it receives is organized into an experiential knowledge structure and this knowledge in turn is used to guide the robot's future actions. A summary is presented of a problem solving system which is being used as a test bed for developing such a robot. The robot currently engages in the behaviors of visual tracking, focusing down, and looking around in a simulated Martian landscape. Finally, some unsolved problems are outlined whose solutions are necessary before an experientally guided robot can be produced. These problems center around organizing the motivational and memory structure of the robot and understanding its high-level control mechanisms.

  11. Inverse treatment planning based on MRI for HDR prostate brachytherapy

    International Nuclear Information System (INIS)

    Citrin, Deborah; Ning, Holly; Guion, Peter; Li Guang; Susil, Robert C.; Miller, Robert W.; Lessard, Etienne; Pouliot, Jean; Xie Huchen; Capala, Jacek; Coleman, C. Norman; Camphausen, Kevin; Menard, Cynthia

    2005-01-01

    Purpose: To develop and optimize a technique for inverse treatment planning based solely on magnetic resonance imaging (MRI) during high-dose-rate brachytherapy for prostate cancer. Methods and materials: Phantom studies were performed to verify the spatial integrity of treatment planning based on MRI. Data were evaluated from 10 patients with clinically localized prostate cancer who had undergone two high-dose-rate prostate brachytherapy boosts under MRI guidance before and after pelvic radiotherapy. Treatment planning MRI scans were systematically evaluated to derive a class solution for inverse planning constraints that would reproducibly result in acceptable target and normal tissue dosimetry. Results: We verified the spatial integrity of MRI for treatment planning. MRI anatomic evaluation revealed no significant displacement of the prostate in the left lateral decubitus position, a mean distance of 14.47 mm from the prostatic apex to the penile bulb, and clear demarcation of the neurovascular bundles on postcontrast imaging. Derivation of a class solution for inverse planning constraints resulted in a mean target volume receiving 100% of the prescribed dose of 95.69%, while maintaining a rectal volume receiving 75% of the prescribed dose of <5% (mean 1.36%) and urethral volume receiving 125% of the prescribed dose of <2% (mean 0.54%). Conclusion: Systematic evaluation of image spatial integrity, delineation uncertainty, and inverse planning constraints in our procedure reduced uncertainty in planning and treatment

  12. Endorectal coil MRI and MR-spectroscopic imaging in patients with elevated serum prostate specific antigen with negative trus transrectal ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Farooq Ahmad Ganie

    2013-01-01

    Conclusion: Prostatic biopsy directed with endorectal coil MRI and MR-spectroscopic imaging findings in patients with elevated serum PSA and prior negative biopsy, improves the early diagnosis of prostatic carcinoma and accurate localization of prostate cancer within the gland.

  13. Usefulness of MRI-assisted metabolic volumetric parameters provided by simultaneous {sup 18}F-fluorocholine PET/MRI for primary prostate cancer characterization

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-il [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University, Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Cancer Research Institute, Seoul (Korea, Republic of); Cheon, Gi Jeong [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Radiological Science Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Nuclear Medicine, 101 Daehak-ro, Chongno-gu, Seoul (Korea, Republic of); Paeng, Jin Chul [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Cho, Jeong Yeon [Seoul National University College of Medicine, Radiological Science Research Institute, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, 101 Daehak-ro, Chongno-gu, Seoul (Korea, Republic of); Kwak, Cheol [Seoul National University Hospital, Department of Urology, Seoul (Korea, Republic of); Kang, Keon Wook; Chung, June-Key [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Radiological Science Research Institute, Seoul (Korea, Republic of); Kim, Euishin Edmund [Seoul National University, Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); University of California, Department of Radiological Sciences, Irvine, CA (United States); Lee, Dong Soo [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University, Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of)

    2015-07-15

    The aim of this study was to determine the usefulness of MRI-assisted positron emission tomography (PET) parameters provided by simultaneous {sup 18}F-fluorocholine (FCH) PET/MRI for characterization of primary prostate cancer. Thirty patients with localized prostate cancer (mean age 69.4 ± 6.7 years) confirmed by biopsy were prospectively enrolled for simultaneous PET/MRI imaging. The patients underwent {sup 18}F-FCH PET/MRI 1 week before undergoing total prostatectomy. Multiple parameters of diffusion-weighted MRI [minimum and mean apparent diffusion coefficient (ADC{sub min} and ADC{sub mean})], metabolic PET [maximum and mean standardized uptake value (SUV{sub max} and SUV{sub mean})], and metabolic volumetric PET [metabolic tumor volume (MTV) and uptake volume product (UVP)] were compared with laboratory, pathologic, and immunohistochemical (IHC) features of the prostate cancer specimen. PET parameters were divided into two categories as follows: volume of interest (VOI) of prostate by SUV cutoff 2.5 (SUV{sub max}, SUV{sub mean}, MTV{sub SUV}, and UVP{sub SUV}) and MRI-assisted VOI of prostate cancer (SUV{sub maxMRI}, SUV{sub meanMRI}, MTV{sub MRI}, and UVP{sub MRI}). The rates of prostate cancer-positive cases identified by MRI alone, {sup 18}F-FCH PET alone, and {sup 18}F-FCH PET/MRI were 83.3, 80.0, and 93.3 %, respectively. Among the multiple PET/MRI parameters, MTV{sub MRI} showed fair correlation with serum prostate-specific antigen (PSA; r = 0.442, p = 0.014) and highest correlation with tumor volume (r = 0.953, p < 0.001). UVP{sub MRI} showed highest correlation with serum PSA (r = 0.531, p = 0.003), good correlation with tumor volume (r = 0.908, p < 0.001), and it was significantly associated with Gleason score (p = 0.041). High MTV{sub MRI} and UVP{sub MRI} values were significant for perineural invasion, lymphatic invasion, extracapsular extension, seminal vesicle invasion, and positive B-cell lymphoma 2 (Bcl-2) expression (all p < 0

  14. MRI-based preplanning in low-dose-rate prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2008-01-01

    Purpose: To compare the dosimetric results between MRI-based and TRUS-based preplanning in permanent prostate brachytherapy, and to estimate the accuracy of MRI-based preplanning by comparing with CT/MRI fusion-based postimplant dosimetry. Methods and materials: Twenty-one patients were entered in this prospective study with written informed consent. MRI-based and TRUS-based preplanning were performed. The seed and needle locations were identical according to MRI-based and TRUS-based preplanning. MRI-based and TRUS-based preplanning were compared using DVH-related parameters. Following brachytherapy, the accuracy of the MRI-based preplanning was evaluated by comparing it with CT/MRI fusion-based postimplant dosimetry. Results: Mean MRI-based prostate volume was slightly underestimated (0.73 cc in mean volume) in comparison to TRUS-based volume. There were no significant differences in the mean DVH-related parameters except with rectal V 100 (cc) between TRUS-based and MRI-based preplanning. Mean rectal V 100 (cc) was 0.74 cc in TRUS-based and 0.29 cc in MRI-based preplanning, respectively, and the values demonstrated a statistical difference. There was no statistical difference in mean rectal V 150 (cc), and rectal V 100 (cc) between MRI-based preplanning and CT/MRI fusion-based postimplant dosimetry. Conclusion: Prostate volume estimation and DVH-related parameters in MRI-based preplanning were almost identical to TRUS-based preplanning. From the results of CT/MRI fusion-based postimplant dosimetry, MRI-based preplanning was therefore found to be a reliable and useful modality, as well as being helpful for TRUS-based preplanning. MRI-based preplanning can more accurately predict postimplant rectal dose than TRUS-based preplanning

  15. Comparison of MRI pulse sequences in defining prostate volume after permanent implantation

    International Nuclear Information System (INIS)

    McLaughlin, P.W.; Narayana, V.; Drake, D.G.; Miller, B.M.; Marsh, L.; Chan, J.; Gonda, R.; Winfield, R.J.; Roberson, P.L.

    2002-01-01

    Purpose: To determine the relative value of three MRI pulse sequences in defining the prostate volume after permanent implantation. Methods and Materials: A total of 45 patients who received a permanent 125 I implant were studied. Two weeks after implantation, an axial CT scan (2 mm thickness) and T 1 -weighted, T 1 -weighted fat saturation, and T 2 -weighted axial MRI (3-mm) studies were obtained. The prostate volumes were compared with the initial ultrasound planning volumes, and subsequently the CT, T 1 -weighted, and T 1 -weighted fat saturation MRI volumes were compared with the T 2 -weighted volumes. Discrepancies in volume were evaluated by visual inspection of the registered axial images and the registration of axial volumes on the sagittal T 2 -weighted volumes. In a limited set of patients, pre- and postimplant CT and T 2 -weighted MRI studies were available for comparison to determine whether prostate volume changes after implant were dependent on the imaging modality. Results: T 1 -weighted and T 1 -weighted fat saturation MRI and CT prostate volumes were consistently larger than the T 2 -weighted MRI prostate volumes, with a volume on average 1.33 (SD 0.24) times the T 2 -weighted volume. This discrepancy was due to the superiority of T 2 -weighted MRI for prostate definition at the following critical interfaces: membranous urethra, apex, and anterior base-bladder and posterior base-seminal vesicle interfaces. The differences in prostate definition in the anterior base region suggest that the commonly reported underdose may be due to overestimation of the prostate in this region by CT. The consistent difference in volumes suggests that the degree of swelling observed after implantation is in part a function of the imaging modality. In patients with pre- and postimplant CT and T 2 -weighted MRI images, swelling on the T 2 -weighted images was 1.1 times baseline and on CT was 1.3 times baseline, confirming the imaging modality dependence of prostate

  16. The value of MRI three-dimensional reconstruction in diagnosis and therapy of prostate cancer

    International Nuclear Information System (INIS)

    Li Feiyu; Wang Xiaoying; Xu Yufeng; Xiao Jiangxi; Jiang Xuexiang

    2006-01-01

    Objective: To evaluate three-dimensional reconstruction of MRI images in diagnosis and therapy of prostate cancer. Methods: Twenty-eight patients with proven prostate cancers were recruited in this study. Seventeen of them were diagnosed as having prostate cancer according to the ultrasound guided systemic biopsy. Their MR examinations showed fourteen lesions in the peripheral zone and three in the central gland of the prostate. The other eleven patients underwent MR examination after a period of treatment, including endocrinetherapy and brachytherapy. Using endorectal coil, a series of T 2 -weighted images were acquired on the axial plane. These source images were processed by 3D-Doctor software to reconstruct into three-dimensional images. Results: In the fourteen patients with peripheral zone cancer, reconstruction images could display the 3D regions of cancer and the involvement of capsular. The outspread of central gland and the compression of peripheral zone in patients with central gland cancer could be revealed in the same way. The volumetric changes of the lesion and the prostate after endocrinetherapy could also be perceived through these 3 D images. Similarly, radioactive seeds were revealed in a spatial manner that could be easily evaluated. Conclusion: Three-dimensional reconstruction images were obtained in all patients. They were able to provide stereotyped information about the lesions and their surrounding tissues. MRI three-dimensional reconstruction can be an adjunctive tool in the evaluation of prostate lesions. (authors)

  17. A urinary biomarker-based risk score correlates with multiparametric MRI for prostate cancer detection.

    Science.gov (United States)

    Hendriks, Rianne J; van der Leest, Marloes M G; Dijkstra, Siebren; Barentsz, Jelle O; Van Criekinge, Wim; Hulsbergen-van de Kaa, Christina A; Schalken, Jack A; Mulders, Peter F A; van Oort, Inge M

    2017-10-01

    Prostate cancer (PCa) diagnostics would greatly benefit from more accurate, non-invasive techniques for the detection of clinically significant disease, leading to a reduction of over-diagnosis and over-treatment. The aim of this study was to determine the association between a novel urinary biomarker-based risk score (SelectMDx), multiparametric MRI (mpMRI) outcomes, and biopsy results for PCa detection. This retrospective observational study used data from the validation study of the SelectMDx score, in which urine was collected after digital rectal examination from men undergoing prostate biopsies. A subset of these patients also underwent a mpMRI scan of the prostate. The indications for performing mpMRI were based on persistent clinical suspicion of PCa or local staging after PCa was found upon biopsy. All mpMRI images were centrally reviewed in 2016 by an experienced radiologist blinded for the urine test results and biopsy outcome. The PI-RADS version 2 was used. In total, 172 patients were included for analysis. Hundred (58%) patients had PCa detected upon prostate biopsy, of which 52 (52%) had high-grade disease correlated with a significantly higher SelectMDx score (P < 0.01). The median SelectMDx score was significantly higher in patients with a suspicious significant lesion on mpMRI compared to no suspicion of significant PCa (P < 0.01). For the prediction of mpMRI outcome, the area-under-the-curve of SelectMDx was 0.83 compared to 0.66 for PSA and 0.65 for PCA3. There was a positive association between SelectMDx score and the final PI-RADS grade. There was a statistically significant difference in SelectMDx score between PI-RADS 3 and 4 (P < 0.01) and between PI-RADS 4 and 5 (P < 0.01). The novel urinary biomarker-based SelectMDx score is a promising tool in PCa detection. This study showed promising results regarding the correlation between the SelectMDx score and mpMRI outcomes, outperforming PCA3. Our results suggest that this risk

  18. MO-B-BRC-04: MRI-Based Prostate HDR

    International Nuclear Information System (INIS)

    Mourtada, F.

    2016-01-01

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions

  19. MO-B-BRC-04: MRI-Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Mourtada, F. [Christiana Care Hospital (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  20. Development of a registration framework to validate MRI with histology for prostate focal therapy.

    Science.gov (United States)

    Reynolds, H M; Williams, S; Zhang, A; Chakravorty, R; Rawlinson, D; Ong, C S; Esteva, M; Mitchell, C; Parameswaran, B; Finnegan, M; Liney, G; Haworth, A

    2015-12-01

    Focal therapy has been proposed as an alternative method to whole-gland treatment for prostate cancer when aiming to reduce treatment side effects. The authors recently validated a radiobiological model which takes into account tumor location and tumor characteristics including tumor cell density, Gleason score, and hypoxia in order to plan optimal dose distributions for focal therapy. The authors propose that this model can be informed using multiparametric MRI (mpMRI) and in this study present a registration framework developed to map prostate mpMRI and histology data, where histology will provide the "ground truth" data regarding tumor location and biology. The authors aim to apply this framework to a growing database to develop a prostate biological atlas which will enable MRI based planning for prostate focal therapy treatment. Six patients scheduled for routine radical prostatectomy were used in this proof-of-concept study. Each patient underwent mpMRI scanning prior to surgery, after which the excised prostate specimen was formalin fixed and mounted in agarose gel in a custom designed sectioning box. T2-weighted MRI of the specimen in the sectioning box was acquired, after which 5 mm sections of the prostate were cut and histology sections were microtomed. A number of image processing and registration steps were used to register histology images with ex vivo MRI and deformable image registration (DIR) was applied to 3D T2w images to align the in vivo and ex vivo MRI data. Dice coefficient metrics and corresponding feature points from two independent annotators were selected in order to assess the DIR accuracy. Images from all six patients were registered, providing histology and in vivo MRI in the ex vivo MRI frame of reference for each patient. Results demonstrated that their DIR methodology to register in vivo and ex vivo 3D T2w MRI improved accuracy in comparison with an initial manual alignment for prostates containing features which were readily visible

  1. Image-guided robotic surgery.

    Science.gov (United States)

    Marescaux, Jacques; Solerc, Luc

    2004-06-01

    Medical image processing leads to an improvement in patient care by guiding the surgical gesture. Three-dimensional models of patients that are generated from computed tomographic scans or magnetic resonance imaging allow improved surgical planning and surgical simulation that offers the opportunity for a surgeon to train the surgical gesture before performing it for real. These two preoperative steps can be used intra-operatively because of the development of augmented reality, which consists of superimposing the preoperative three-dimensional model of the patient onto the real intraoperative view. Augmented reality provides the surgeon with a view of the patient in transparency and can also guide the surgeon, thanks to the real-time tracking of surgical tools during the procedure. When adapted to robotic surgery, this tool tracking enables visual serving with the ability to automatically position and control surgical robotic arms in three dimensions. It is also now possible to filter physiologic movements such as breathing or the heart beat. In the future, by combining augmented reality and robotics, these image-guided robotic systems will enable automation of the surgical procedure, which will be the next revolution in surgery.

  2. NASA Robotic Neurosurgery Testbed

    Science.gov (United States)

    Mah, Robert

    1997-01-01

    The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

  3. Performance Comparison of 1.5 T Endorectal Coil MRI with Non-Endorectal Coil 3.0 T MRI in Patients with Prostate Cancer

    Science.gov (United States)

    Shah, Zarine K.; Elias, Saba N.; Abaza, Ronney; Zynger, Debra L.; DeRenne, Lawrence A.; Knopp, Michael V.; Guo, Beibei; Schurr, Ryan; Heymsfield, Steven B.; Jia, Guang

    2015-01-01

    Rationale and Objectives To compare prostate morphology, image quality, and diagnostic performance of 1.5 T endorectal coil MRI and 3.0 T non-endorectal coil MRI in patients with prostate cancer. Materials and Methods MR images obtained of 83 patients with prostate cancer using 1.5 T MRI systems with an endorectal coil were compared to images collected from 83 patients with a 3.0 T MRI system. Prostate diameters were measured and image quality was evaluated by one ABR-certified radiologist (Reader 1) and one ABR-certified diagnostic medical physicist (Reader 2). The likelihood of the peripheral zone cancer presence in each sextant and local extent were rated and compared with histopathologic findings. Results Prostate anterior-posterior diameter measured by both readers was significantly shorter with 1.5 T endorectal MRI than with 3.0 T MRI. The overall image quality score difference was significant only for Reader 1. Both readers found that the two MRI systems provided similar diagnostic accuracy in cancer localization, extraprostatic extension, and seminal vesicle involvement. Conclusion Non-endorectal coil 3.0 T MRI provides prostate images that are natural in shape and that have comparable image quality to those obtained at 1.5 T with an endorectal coil, but not superior diagnostic performance. These findings suggest an opportunity exists for improving technical aspects of 3.0 T prostate MRI. PMID:25579637

  4. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  5. MRI to assess chemoprevention in transgenic adenocarcinoma of mouse prostate (TRAMP)

    International Nuclear Information System (INIS)

    Arbab, Ali S; Shankar, Adarsh; Varma, Nadimpalli RS; Deeb, Dorrah; Gao, Xiaohua; Iskander, ASM; Janic, Branislava; Ali, Meser M; Gautam, Subhash C

    2011-01-01

    The current method to determine the efficacy of chemoprevention in TRAMP mouse model of carcinoma of prostate (CaP) is by extracting and weighing the prostate at different time points or by immunohistochemistry analysis. Non-invasive determination of volumes of prostate glands and seminal vesicles before, during and after treatment would be valuable in investigating the efficacy of newer chemopreventive agents in CaP. The purpose of this study was to determine whether in vivo magnetic resonance imaging (MRI) using a 3 tesla clinical MRI system can be used to follow the effect of chemoprevention in TRAMP model of mouse CaP. Mice were randomized into control and treated groups. The animals in treated group received 10 µmol/kg of CDDO, 5 days a week for 20 weeks. Animals underwent in vivo MRI of prostate gland and seminal vesicles by a clinical 3 Tesla MRI system just before (at 5 weeks), during and at the end of treatment, at 25 weeks. T1-weighted and fat saturation (FATSAT) multiecho fast spin echo T2- weighted images (T2WI) were acquired. Volume of the prostate glands and seminal vesicles was determined from MR images. T2 signal intensity changes in the seminal vesicles were determined by subtracting higher echo time (TE) from lower TE T2WI. Following treatments all animals were sacrificed, prostate and seminal vesicles collected, and the tissues prepared for histological staining. All data were expressed as mean ± 1 standard deviation. Two-way or multivariate analysis of variance followed by post-hoc test was applied to determine the significant differences. A p-value of <0.05 was considered significant. Histological analysis indicated tumor in 100% of control mice, whereas 10% of the treated mice showed tumor in prostate gland. Both MRI and measured prostate weights showed higher volume/weight in control mouse group. MRI showed significantly higher volume of seminal vesicles in control animals and T2 signal intensity changes in seminal vesicles of control mice

  6. Sequential evaluation of prostate edema after permanent seed prostate brachytherapy using CT-MRI fusion

    International Nuclear Information System (INIS)

    Taussky, Daniel; Austen, Lyn; Toi, Ants; Yeung, Ivan; Williams, Theresa; Pearson, Shannon; McLean, Michael; Pond, Gregory; Crook, Juanita

    2005-01-01

    Purpose: To analyze the extent and time course of prostate edema and its effect on dosimetry after permanent seed prostate brachytherapy. Methods and Materials: Twenty patients scheduled for permanent seed 125 I prostate brachytherapy agreed to a prospective study on postimplant edema. Implants were preplanned using transrectal ultrasonography. Postimplant dosimetry was calculated using computed tomography-magnetic resonance imaging (CT-MRI) fusion on the day of the implant (Day 1) and Days 8 and 30. The prostate was contoured on MRI, and the seeds were located on CT. Factors investigated for an influence on edema were the number of seeds and needles, preimplant prostate volume, transitional zone index (transition zone volume divided by prostate volume), age, and prostate-specific antigen level. Prostate dosimetry was evaluated by the percentage of the prostate volume receiving 100% of the prescribed dose (V 100 ) and percentage of prescribed dose received by 90% of the prostate volume (D 90 ). Results: Prostate edema was maximal on Day 1, with the median prostate volume 31% greater than preimplant transrectal ultrasound volume (range, 0.93-1.72; p 100 on Day 1 was 93.6% (range, 86.0-98.2%) and was 96.3% (range, 85.7-99.5%) on Day 30 (p = 0.079). Patients with a Day 1 V 100 >93% were less affected by edema resolution, showing a median increase in V 100 of 0.67% on Day 30 compared with 2.77% for patients with a V 100 100 >93%)

  7. Diffusion-weighted MRI for detecting prostate tumour in men at increased genetic risk

    International Nuclear Information System (INIS)

    Souza, Nandita M. de; Morgan, Veronica A.; Bancroft, Elizabeth; Sohaib, S. Aslam; Giles, Sharon L.; Kote-Jarai, Zsofia; Castro, Elena; Hazell, Steven; Jafar, Maysam; Eeles, Rosalind

    2014-01-01

    •Endorectal T2W + DW-MRI is potentially useful for prostate cancer screening.•MRI is specific for detecting prostate cancer in men with increased genetic risk.•Detection of prostate cancer in men at genetically low risk with MRI is limited. Endorectal T2W + DW-MRI is potentially useful for prostate cancer screening. MRI is specific for detecting prostate cancer in men with increased genetic risk. Detection of prostate cancer in men at genetically low risk with MRI is limited. Diffusion-weighted (DW)-MRI is invaluable in detecting prostate cancer. We determined its sensitivity and specificity and established interobserver agreement for detecting tumour in men with a family history of prostate cancer stratified by genetic risk. 51 men with a family history of prostate cancer underwent T2-W + DW-endorectal MRI at 3.0 T. Presence of tumour was noted at right and left apex, mid and basal prostate sextants by 2 independent observers, 1 experienced and the other inexperienced in endorectal MRI. Sensitivity and specificity against a 10-core sampling technique (lateral and medial cores at each level considered together) in men with >2× population risk based on 71 SNP analysis versus those with lower genetic risk scores was established. Interobserver agreement was determined at a subject level. Biopsies indicated cancer in 28 sextants in 13/51 men; 32 of 51 men had twice the population risk (>0.25) based on 71 SNP profiling. Sensitivity/specificity per-subject for patients was 90.0%/86.4% (high-risk) vs. 66.7%/100% (low-risk, observer 1) and 60.0%/86.3% (high-risk) vs. 33.3%/93.8% (low-risk, observer 2) with moderate overall inter-observer agreement (kappa = 0.42). Regional sensitivities/specificities for high-risk vs. low-risk for observer 1 apex 72.2%/100% [33.3%/100%], mid 100%/93.1% [100%/97.3%], base 16.7%/98.3% [0%/100%] and for observer 2 apex 36.4%/98.1% [0%/100%], mid 28.6%/96.5% [100%/100%], base 20%/100% [0%/97.3%] were poorer as they failed to detect

  8. In vivo MRI volumetric measurement of prostate regression and growth in mice

    Directory of Open Access Journals (Sweden)

    Nalcioglu Orhan

    2007-07-01

    Full Text Available Abstract Background Mouse models for treatment of late-stage prostate cancer are valuable tools, but assessing the extent of growth of the prostate and particularly its regression due to therapeutic intervention or castration is difficult due to the location, small size and interdigitated anatomy of the prostate gland in situ. Temporal monitoring of mouse prostate regression requires multiple animals and examination of histological sections. Methods Initially, T2-weighted magnetic resonance imaging (MRI was performed on normal year-old C57/BL6 mice. Individual mice were repeatedly imaged using inhalation anesthesia to establish the reproducibility of the method and to follow hormone manipulation of the prostate volume. Subsequently, MRI fat signal was suppressed using a chemical shift-selective (CHESS pulse to avoid signal contamination and enhance discrimination of the prostate. Results High field (7T MRI provides high resolution (117 × 117 μm in plane, highly reproducible images of the normal mouse prostate. Despite long imaging times, animals can be imaged repeatedly to establish reliability of volume measurements. Prostate volume declines following castration and subsequently returns to normal with androgen administration in the same animal. CHESS imaging allowed discrimination of both the margins of the prostate and the dorsal-lateral lobes of the prostate (DLP from the ventral lobes (VP. Castration results in a 40% reduction in the volume of the DLP and a 75% reduction in the volume of the VP. Conclusion MRI assessment of the volume of the mouse prostate is precise and reproducible. MRI improves volumetric determination of the extent of regression and monitoring of the same mouse over time during the course of treatment is possible. Since assessing groups of animals at each time point is avoided, this improves the accuracy of the measurement of any manipulation effect and reduces the number of animals required.

  9. Multiparametric prostate MRI: technical conduct, standardized report and clinical use.

    Science.gov (United States)

    Manfredi, Matteo; Mele, Fabrizio; Garrou, Diletta; Walz, Jochen; Fütterer, Jurgen J; Russo, Filippo; Vassallo, Lorenzo; Villers, Arnauld; Emberton, Mark; Valerio, Massimo

    2018-02-01

    Multiparametric prostate MRI (mp-MRI) is an emerging imaging modality for diagnosis, characterization, staging, and treatment planning of prostate cancer (PCa). The technique, results reporting, and its role in clinical practice have been the subject of significant development over the last decade. Although mp-MRI is not yet routinely used in the diagnostic pathway, almost all urological guidelines have emphasized the potential role of mp-MRI in several aspects of PCa management. Moreover, new MRI sequences and scanning techniques are currently under evaluation to improve the diagnostic accuracy of mp-MRI. This review presents an overview of mp-MRI, summarizing the technical applications, the standardized reporting systems used, and their current roles in various stages of PCa management. Finally, this critical review also reports the main limitations and future perspectives of the technique.

  10. Reliability of multiparametric prostatic MRI quantitative data in the evaluation of prostate cancer aggressiveness

    Directory of Open Access Journals (Sweden)

    Haisam Atta

    2017-09-01

    Full Text Available Purpose: To compare the quantitative data of multiparametric prostatic MRI with Gleason scores of histopathological analysis. Materials and methods: One hundred twenty-two patients performed Multiparametric MRI of the prostate. Functional MRI quantitative data (including diffusion with mean ADC value and spectroscopic metabolic ratio where the DWI is employing b 50, 400, 800, 1000 and 2000 sec/mm2 and multivoxel MR spectroscopy compared with of Gleason scores of histopathological results. Malignant cases are classified into three groups according to their Gleason score as group I with Gleason score ≤6, group II Gleason score 7, while Gleason score 8–10 stratified as Group III. Results: The histopathological analysis reveals 78 malignant cases and 44 benign Cases. The significant statistical difference between group I and the other two groups (p < 0.001 regarding the quantitative mean ADC value and metabolic spectroscopic ratio. No significant statistical difference between group II and III with p = 0.2 for mean ADC difference and p = 0.8 for the metabolic spectroscopic ratio with a weak negative correlation between ADCand Gleason score [rs = −0.26] and significant positive correlation (p = 0.02 for MRSI metabolic ratio [rs = 0.2]. Conclusion: The quantitative data of functional imaging of the prostate is reliable in evaluating prostatic cancer aggressiveness and proper construction of therapeutic plan. Keywords: mpMRI prostate cancer aggressiveness

  11. SU-G-JeP3-03: Effect of Robot Pose On Beam Blocking for Ultrasound Guided SBRT of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, S; Schlaefer, A [Hamburg University of Technology, Hamburg (Germany); Kuhlemann, I; Ernst, F [Universitaet zu Luebeck, Luebeck (Germany); Fuerweger, C [European Cyberknife Center Munich, Munich (Germany)

    2016-06-15

    Purpose: Ultrasound presents a fast, volumetric image modality for real-time tracking of abdominal organ motion. How-ever, ultrasound transducer placement during radiation therapy is challenging. Recently, approaches using robotic arms for intra-treatment ultrasound imaging have been proposed. Good and reliable imaging requires placing the transducer close to the PTV. We studied the effect of a seven degrees of freedom robot on the fea-sible beam directions. Methods: For five CyberKnife prostate treatment plans we established viewports for the transducer, i.e., points on the patient surface with a soft tissue view towards the PTV. Choosing a feasible transducer pose and using the kinematic redundancy of the KUKA LBR iiwa robot, we considered three robot poses. Poses 1 to 3 had the elbow point anterior, superior, and inferior, respectively. For each pose and each beam starting point, the pro-jections of robot and PTV were computed. We added a 20 mm margin accounting for organ / beam motion. The number of nodes for which the PTV was partially of fully blocked were established. Moreover, the cumula-tive overlap for each of the poses and the minimum overlap over all poses were computed. Results: The fully and partially blocked nodes ranged from 12% to 20% and 13% to 27%, respectively. Typically, pose 3 caused the fewest blocked nodes. The cumulative overlap ranged from 19% to 29%. Taking the minimum overlap, i.e., considering moving the robot’s elbow while maintaining the transducer pose, the cumulative over-lap was reduced to 16% to 18% and was 3% to 6% lower than for the best individual pose. Conclusion: Our results indicate that it is possible to identify feasible ultrasound transducer poses and to use the kinematic redundancy of a 7 DOF robot to minimize the impact of the imaging subsystem on the feasible beam directions for ultrasound guided and motion compensated SBRT. Research partially funded by DFG grants ER 817/1-1 and SCHL 1844/3-1.

  12. SU-G-JeP3-03: Effect of Robot Pose On Beam Blocking for Ultrasound Guided SBRT of the Prostate

    International Nuclear Information System (INIS)

    Gerlach, S; Schlaefer, A; Kuhlemann, I; Ernst, F; Fuerweger, C

    2016-01-01

    Purpose: Ultrasound presents a fast, volumetric image modality for real-time tracking of abdominal organ motion. How-ever, ultrasound transducer placement during radiation therapy is challenging. Recently, approaches using robotic arms for intra-treatment ultrasound imaging have been proposed. Good and reliable imaging requires placing the transducer close to the PTV. We studied the effect of a seven degrees of freedom robot on the fea-sible beam directions. Methods: For five CyberKnife prostate treatment plans we established viewports for the transducer, i.e., points on the patient surface with a soft tissue view towards the PTV. Choosing a feasible transducer pose and using the kinematic redundancy of the KUKA LBR iiwa robot, we considered three robot poses. Poses 1 to 3 had the elbow point anterior, superior, and inferior, respectively. For each pose and each beam starting point, the pro-jections of robot and PTV were computed. We added a 20 mm margin accounting for organ / beam motion. The number of nodes for which the PTV was partially of fully blocked were established. Moreover, the cumula-tive overlap for each of the poses and the minimum overlap over all poses were computed. Results: The fully and partially blocked nodes ranged from 12% to 20% and 13% to 27%, respectively. Typically, pose 3 caused the fewest blocked nodes. The cumulative overlap ranged from 19% to 29%. Taking the minimum overlap, i.e., considering moving the robot’s elbow while maintaining the transducer pose, the cumulative over-lap was reduced to 16% to 18% and was 3% to 6% lower than for the best individual pose. Conclusion: Our results indicate that it is possible to identify feasible ultrasound transducer poses and to use the kinematic redundancy of a 7 DOF robot to minimize the impact of the imaging subsystem on the feasible beam directions for ultrasound guided and motion compensated SBRT. Research partially funded by DFG grants ER 817/1-1 and SCHL 1844/3-1.

  13. Dynamic contrast-enhanced MRI of benign prostatic hyperplasia and prostatic carcinoma: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ren, J.; Huan, Y.; Wang, H.; Chang, Y.-J.; Zhao, H.-T.; Ge, Y.-L.; Liu, Y.; Yang, Y.

    2008-01-01

    Aim: To investigate the diagnostic and differential diagnostic values of dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) in prostatic diseases, and to investigate the correlation between the parameters of SI-T curves and angiogenesis. Materials and methods: Twenty-one patients with proven prostatic carcinoma (Pca) and 29 patients with proven benign prostatic hyperplasia (BPH) were examined using DCE MRI. Diagnostic characteristics for differentiation were examined using threshold values for maximum peak time, enhancement degree, and enhancement rate. Then, the signal intensity-time curves (SI-T curves) were analysed, and the correlations between the parameters of SI-T curves and the expression levels of vascular endothelial growth factor (VEGF) and microvascular density (MVD) were investigated. All patients underwent prostatectomy. DCE MRI and histological findings were correlated. Results: Pca showed stronger enhancement with an earlier peak time, higher enhancement, and enhancement rate (p 2 = 13.57, P < 0.005). The VEGF and MVD expression levels of Pca were higher than those of BPH. Peak time was negatively correlated with the expression levels of VEGF and MVD, whereas the enhancement degree and enhancement rate showed positive correlations (Pearson correlation, p < 0.05). Conclusion: Based on T2-weighted imaging, DCE MRI curves can help to differentiate benign from malignant prostate tissue. In the present study the type C curve was rarely seen with malignant disease, but these results need confirmation

  14. Adaptation of a haptic robot in a 3T fMRI.

    Science.gov (United States)

    Snider, Joseph; Plank, Markus; May, Larry; Liu, Thomas T; Poizner, Howard

    2011-10-04

    Functional magnetic resonance imaging (fMRI) provides excellent functional brain imaging via the BOLD signal with advantages including non-ionizing radiation, millimeter spatial accuracy of anatomical and functional data, and nearly real-time analyses. Haptic robots provide precise measurement and control of position and force of a cursor in a reasonably confined space. Here we combine these two technologies to allow precision experiments involving motor control with haptic/tactile environment interaction such as reaching or grasping. The basic idea is to attach an 8 foot end effecter supported in the center to the robot allowing the subject to use the robot, but shielding it and keeping it out of the most extreme part of the magnetic field from the fMRI machine (Figure 1). The Phantom Premium 3.0, 6DoF, high-force robot (SensAble Technologies, Inc.) is an excellent choice for providing force-feedback in virtual reality experiments, but it is inherently non-MR safe, introduces significant noise to the sensitive fMRI equipment, and its electric motors may be affected by the fMRI's strongly varying magnetic field. We have constructed a table and shielding system that allows the robot to be safely introduced into the fMRI environment and limits both the degradation of the fMRI signal by the electrically noisy motors and the degradation of the electric motor performance by the strongly varying magnetic field of the fMRI. With the shield, the signal to noise ratio (SNR: mean signal/noise standard deviation) of the fMRI goes from a baseline of ~380 to ~330, and ~250 without the shielding. The remaining noise appears to be uncorrelated and does not add artifacts to the fMRI of a test sphere (Figure 2). The long, stiff handle allows placement of the robot out of range of the most strongly varying parts of the magnetic field so there is no significant effect of the fMRI on the robot. The effect of the handle on the robot's kinematics is minimal since it is lightweight (~2

  15. Prostate cancer detection using multiparametric 3 – tesla MRI and fusion biopsy: preliminary results

    Directory of Open Access Journals (Sweden)

    Thais Caldara Mussi

    Full Text Available ABSTRACT Objective: To evaluate the diagnostic efficacy of transrectal ultrasonography (US biopsy with imaging fusion using multiparametric (mp magnetic resonance imaging (MRI in patients with suspicion of prostate cancer (PCa, with an emphasis on clinically significant tumors according to histological criteria. Materials and Methods: A total of 189 consecutive US/MRI fusion biopsies were performed obtaining systematic and guided samples of suspicious areas on mpMRI using a 3 Tesla magnet without endorectal coil. Clinical significance for prostate cancer was established based on Epstein criteria. Results: In our casuistic, the average Gleason score was 7 and the average PSA was 5.0ng/mL. Of the 189 patients that received US/MRI biopsies, 110 (58.2% were positive for PCa. Of those cases, 88 (80% were clinically significant, accounting for 46.6% of all patients. We divided the MRI findings into 5 Likert scales of probability of having clinically significant PCa. The positivity of US/MRI biopsy for clinically significant PCa was 0%, 17.6% 23.5%, 53.4% and 84.4% for Likert scores 1, 2, 3, 4 and 5, respectively. There was a statistically significant difference in terms of biopsy results between different levels of suspicion on mpMRI and also when biopsy results were divided into groups of clinically non-significant versus clinically significant between different levels of suspicion on mpMRI (p-value <0.05 in both analyzes. Conclusion: We found that there is a significant difference in cancer detection using US/MRI fusion biopsy between low-probability and intermediate/high probability Likert scores using mpMRI.

  16. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer; MRT-gezielte interventionelle Verfahren zur Abklaerung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Division fuer Molekulare und Gender-Bildgebung, Wien (Austria); Margreiter, M. [Medizinische Universitaet Wien, Univ.-Klinik fuer Urologie, Wien (Austria)

    2011-11-15

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [German] Neben dem transrektalen Ultraschall (TRUS) hat sich in den letzten Jahren die MRT als nichtinvasive Methode zur Bildgebung von Prostatatumoren etabliert. Mittels T2-gewichteter Sequenzen ist eine exakte anatomische Darstellung der Prostata und ihrer umliegenden Strukturen moeglich. Andere MRT-Techniken ermoeglichen Rueckschluesse auf das biologische Verhalten des Tumors: dynamische kontrastmittelverstaerkte T1-gewichtete Sequenzen zur Darstellung der Angiogenese, diffusionsgewichtete Aufnahmen zur Beurteilung der Zelldichte und die Spektroskopie zur Bestimmung von Gewebemetaboliten wie Cholin und Kreatin (multiparametrische Bildgebung). Prostatatumoren, die nur mittels MRT nachweisbar sind oder verdaechtige Tumoren, die hauptsaechlich anterior in der Prostata lokalisiert sind und in wiederholten TRUS-gezielten Biopsien verfehlt wurden, benoetigen eine MRT-gezielte Biopsie zur Diagnosesicherung. Die bisherigen

  17. Incorporation of Novel MRI and Biomarkers into Prostate Cancer Active Surveillance Risk Assessment

    Science.gov (United States)

    2017-09-01

    attending the MRI Ultrasound Fusion Guided Prostate biopsy II session at the American Urological Association 2017 annual meeting along with several...MV, Raman JD, Spears V, Stroup SP. An Update of the American Urological Association White Paper on the Prevention and Treatment of the More Common...support (no). Galván GC1, Johnson CB1, Price RS2, Liss MA3, Jolly CA1, deGraffenried LA1. Effects of Obesity on the Regulation of Macrophage

  18. Case of prostate cancer with anterior localization multiparametric MRI study

    International Nuclear Information System (INIS)

    Georgiev, A.

    2016-01-01

    Prostate cancer most often originates from acinar epithelium. Most of the clinically palpable carcinomas are located predominantly in the rear/dorzo-lateraI zones of the gland, but the tumors in the transition zone anatomical may spread to the periphery. The detection of a neoplastic process in the front parts of the gland is rare and poses difficulties in diagnosis. We present a rare case of anterior location of prostate carcinoma with invasion of bladder, blood vessels and seminal vesicles. At present, diagnosis of prostate cancer in most men is demonstrated by elevated serum levels of prostate-specific antigen (PSA), or positive rectal examination or ultrasonography. Multi parametric MR study is a promising method for detecting prostate cancer. When used in conjunction with PSA values and rectal examination, MRI is increasingly accepted as a standard for the diagnosis and characterization of prostate carcinoma. Key words; Prostate Cancer. Anterior Localization. Multi Parametric MRI

  19. MRI-guided procedures in various regions of the body using a robotic assistance system in a closed-bore scanner: preliminary clinical experience and limitations.

    Science.gov (United States)

    Moche, Michael; Zajonz, Dirk; Kahn, Thomas; Busse, Harald

    2010-04-01

    To present the clinical setup and workflow of a robotic assistance system for image-guided interventions in a conventional magnetic resonance imaging (MRI) environment and to report our preliminary clinical experience with percutaneous biopsies in various body regions. The MR-compatible, servo-pneumatically driven, robotic device (Innomotion) fits into the 60-cm bore of a standard MR scanner. The needle placement (n = 25) accuracy was estimated by measuring the 3D deviation between needle tip and prescribed target point in a phantom. Percutaneous biopsies in six patients and different body regions were planned by graphically selecting entry and target points on intraoperatively acquired roadmap MR data. For insertion depths between 29 and 95 mm, the average 3D needle deviation was 2.2 +/- 0.7 mm (range 0.9-3.8 mm). Patients with a body mass index of up to approximately 30 kg/m(2) fitted into the bore with the device. Clinical work steps and limitations are reported for the various applications. All biopsies were diagnostic and could be completed without any major complications. Median planning and intervention times were 25 (range 20-36) and 44 (36-68) minutes, respectively. Preliminary clinical results in a standard MRI environment suggest that the presented robotic device provides accurate guidance for percutaneous procedures in various body regions. Shorter procedure times may be achievable by optimizing technical and workflow aspects. (c) 2010 Wiley-Liss, Inc.

  20. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  1. MRI to predict prostate growth and development in children, adolescents and young adults.

    Science.gov (United States)

    Ren, Jing; Liu, Huijia; Wang, He; Wen, Didi; Huang, Xufang; Ren, Fang; Huan, Yi

    2015-02-01

    The purpose of this study was to investigate the use of MRI in predicting prostate growth and development. A total of 1,500 healthy male volunteers who underwent MRI of the pelvis were included in this prospective study. Subjects were divided into five groups according to age (group A, 2-5 years; group B, 6-10 years; group C, 11-15 years; group D, 16-20 years; group E, 21-25 years). Total prostate volume (TPV) as well as prostate central zone (CZ) and peripheral zone (PZ) were measured and evaluated on MRI. Data of the different groups were compared using variance analysis, Scheffé's method, Kruskal-Wallis H-test, and Pearson's correlation. Statistical significance was inferred at P development scores were 0.08, 0.69, 1.56, 2.38, and 2.74, respectively. Both TPVs and zonal anatomy scores varied significantly among the five groups (P = 0.000). TPV and zonal anatomy score increased with increasing age. MRI provides a reliable quantitative reference for prostate growth and development. • When and how the prostate develops after birth remains unclear. • Prostate volume increases rapidly after the age of 10 years. • MRI provides a reliable objective and quantitative reference for prostate growth and development.

  2. Using manual prostate contours to enhance deformable registration of endorectal MRI.

    Science.gov (United States)

    Cheung, M R; Krishnan, K

    2012-10-01

    Endorectal MRI provides detailed images of the prostate anatomy and is useful for radiation treatment planning. Here we describe a Demons field-initialized B-spline deformable registration of prostate MRI. T2-weighted endorectal MRIs of five patients were used. The prostate and the tumor of each patient were manually contoured. The planning MRIs and their segmentations were simulated by warping the corresponding endorectal MRIs using thin plate spline (TPS). Deformable registration was initialized using the deformation field generated using Demons algorithm to map the deformed prostate MRI to the non-deformed one. The solution was refined with B-Spline registration. Volume overlap similarity was used to assess the accuracy of registration and to suggest a minimum margin to account for the registration errors. Initialization using Demons algorithm took about 15 min on a computer with 2.8 GHz Intel, 1.3 GB RAM. Refinement B-spline registration (200 iterations) took less than 5 min. Using the synthetic images as the ground truth, at zero margin, the average (S.D.) 98 (±0.4)% for prostate coverage was 97 (±1)% for tumor. The average (±S.D.) treatment margin required to cover the entire prostate was 1.5 (±0.2)mm. The average (± S.D.) treatment margin required to cover the tumor was 0.7 (±0.1)mm. We also demonstrated the challenges in registering an in vivo deformed MRI to an in vivo non-deformed MRI. We here present a deformable registration scheme that can overcome large deformation. This platform is expected to be useful for prostate cancer radiation treatment planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  4. "Textural analysis of multiparametric MRI detects transition zone prostate cancer".

    Science.gov (United States)

    Sidhu, Harbir S; Benigno, Salvatore; Ganeshan, Balaji; Dikaios, Nikos; Johnston, Edward W; Allen, Clare; Kirkham, Alex; Groves, Ashley M; Ahmed, Hashim U; Emberton, Mark; Taylor, Stuart A; Halligan, Steve; Punwani, Shonit

    2017-06-01

    To evaluate multiparametric-MRI (mpMRI) derived histogram textural-analysis parameters for detection of transition zone (TZ) prostatic tumour. Sixty-seven consecutive men with suspected prostate cancer underwent 1.5T mpMRI prior to template-mapping-biopsy (TPM). Twenty-six men had 'significant' TZ tumour. Two radiologists in consensus matched TPM to the single axial slice best depicting tumour, or largest TZ diameter for those with benign histology, to define single-slice whole TZ-regions-of-interest (ROIs). Textural-parameter differences between single-slice whole TZ-ROI containing significant tumour versus benign/insignificant tumour were analysed using Mann Whitney U test. Diagnostic accuracy was assessed by receiver operating characteristic area under curve (ROC-AUC) analysis cross-validated with leave-one-out (LOO) analysis. ADC kurtosis was significantly lower (p Textural features of the whole prostate TZ can discriminate significant prostatic cancer through reduced kurtosis of the ADC-histogram where significant tumour is included in TZ-ROI and reduced T1 entropy independent of tumour inclusion. • MR textural features of prostate transition zone may discriminate significant prostatic cancer. • Transition zone (TZ) containing significant tumour demonstrates a less peaked ADC histogram. • TZ containing significant tumour reveals higher post-contrast T1-weighted homogeneity. • The utility of MR texture analysis in prostate cancer merits further investigation.

  5. Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)

    International Nuclear Information System (INIS)

    Ghilezan, Michel J.; Jaffray, David A.; Siewerdsen, Jeffrey H.; Herk, Marcel van; Shetty, Anil; Sharpe, Michael B.; Zafar Jafri, Syed; Vicini, Frank A.; Matter, Richard C.; Brabbins, Donald S.; Martinez, Alvaro A.

    2005-01-01

    Purpose: To quantify prostate motion during a radiation therapy treatment using cine-magnetic resonance imaging (cine-MRI) for time frames comparable to that expected in an image-guided radiation therapy treatment session (20-30 min). Materials and Methods: Six patients undergoing radiation therapy for prostate cancer were imaged on 3 days, over the course of therapy (Weeks 1, 3, and 5). Four hundred images were acquired during the 1-h MRI session in 3 sagittal planes through the prostate at 6-s intervals. Eleven anatomic points of interest (POIs) have been used to characterize prostate/bony pelvis/abdominal wall displacement. Motion traces and standard deviation for each of the 11 POIs have been determined. The probability of displacement over time has also been calculated. Results: Patients were divided into 2 groups according to rectal filling status: full vs. empty rectum. The displacement of POIs (standard deviation) ranged from 0.98 to 1.72 mm for the full-rectum group and from 0.68 to 1.04 mm for the empty-rectum group. The low standard deviations in position (2 mm or less) would suggest that these excursions have a low frequency of occurrence. The most sensitive prostate POI to rectal wall motion was the midposterior with a standard deviation of 1.72 mm in the full-rectum group vs. 0.79 mm in the empty-rectum group (p 0.0001). This POI has a 10% probability of moving more than 3 mm in a time frame of ∼1 min if the rectum is full vs. ∼20 min if the rectum is empty. Conclusion: Motion of the prostate and seminal vesicles during a time frame similar to a standard treatment session is reduced compared to that reported in interfraction studies. The most significant predictor for intrafraction prostate motion is the status of rectal filling. A prostate displacement of <3 mm (90%) can be expected for the 20 min after the moment of initial imaging for patients with an empty rectum. This is not the case for patients presenting with full rectum. The determination

  6. The CI-ROB project: real time monitoring for a robotic prostate curietherapy; Projet CI-ROB: surveillance en temps reel pour curietherapie robotisee de prostate

    Energy Technology Data Exchange (ETDEWEB)

    Liem, X.; Lartigau, E. [Centre Oscar-Lambret, 59 - Lille (France); Coelen, V.; Merzouki, R. [Polytech-Lille, 59 - Lille (France)

    2010-10-15

    The authors present a project which is still at the proto-typing stage and for which hardware and software are still being developed, and which aims at developing a full line for a robotic curietherapy. It comprises an articulated robotic arm with six degree of freedom, and is based on an auto-regulated loop with real time monitoring and control. An echographic probe acquires the prostate images in real time. An adaptive detection defines the prostate contour. This is performed in a virtual environment which comprises the prostate phantom, the robot and the intervention table. The target is defined in the virtual environment (image coordinates) and coordinates are transmitted to the robot controller which defines the robot movements by using the inverse geometric model. Short communication

  7. MR-guided transgluteal biopsies with an open low-field system in patients with clinically suspected prostate cancer: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, Stephan [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany); Johann Wolfgang Goethe-University, Institute for Diagnostic and Interventional Radiology, Frankfurt/Main (Germany); Eichler, Katrin; Engelmann, Kerstin; Ahmed, Mukhtiar; Dettmer, Sebastian; Herzog, Christopher; Pegios, Wasilios; Wetter, A.; Lehnert, Thomas; Mack, Martin G.; Vogl, Thomas J. [Johann Wolfgang Goethe-University, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt/Main (Germany)

    2005-01-01

    The purpose of this study was to examine the feasibility and safety of MR-guided biopsies with a transgluteal approach in patients with uncertain or suspicious prostate lesions. Twenty-five patients with uncertain or suspicious focal prostate lesions detected by high-field MR imaging of the prostate gland using endorectal coil imaging were biopsied with a transgluteal approach in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted FLASH sequences. The prostate gland was biopsied repeatedly with a coaxial technique through a 15-gauge pencil tip with a 16-gauge biopsy handy (median 3.8 samples per patient). Complications and biopsy findings were documented retrospectively. Using T1-weighted sequences biopsy procedures were performed successfully with MR guidance in all cases without any side effects or complications. The median intervention time was 11.3 min. Pathological findings revealed ten cases of hyperplasia or atrophy, three cases of prostatitis, ten cases of carcinoma and two cases of normal tissue. The clinical follow-up showed that in two patients prostate cancer was missed at MR-guided biopsy. Transgluteal MR-guided biopsy of the prostate gland is a safe and promising approach for histological clarification of uncertain or suspicious lesions. (orig.)

  8. Early observed transient prostate-specific antigen elevations on a pilot study of external beam radiation therapy and fractionated MRI guided High Dose Rate brachytherapy boost

    International Nuclear Information System (INIS)

    Singh, Anurag K; Godette, Denise J; Stall, Bronwyn R; Coleman, C Norman; Camphausen, Kevin; Ménard, Cynthia; Guion, Peter; Susil, Robert C; Citrin, Deborah E; Ning, Holly; Miller, Robert W; Ullman, Karen; Smith, Sharon; Crouse, Nancy Sears

    2006-01-01

    To report early observation of transient PSA elevations on this pilot study of external beam radiation therapy and magnetic resonance imaging (MRI) guided high dose rate (HDR) brachytherapy boost. Eleven patients with intermediate-risk and high-risk localized prostate cancer received MRI guided HDR brachytherapy (10.5 Gy each fraction) before and after a course of external beam radiotherapy (46 Gy). Two patients continued on hormones during follow-up and were censored for this analysis. Four patients discontinued hormone therapy after RT. Five patients did not receive hormones. PSA bounce is defined as a rise in PSA values with a subsequent fall below the nadir value or to below 20% of the maximum PSA level. Six previously published definitions of biochemical failure to distinguish true failure from were tested: definition 1, rise >0.2 ng/mL; definition 2, rise >0.4 ng/mL; definition 3, rise >35% of previous value; definition 4, ASTRO defined guidelines, definition 5 nadir + 2 ng/ml, and definition 6, nadir + 3 ng/ml. Median follow-up was 24 months (range 18–36 mo). During follow-up, the incidence of transient PSA elevation was: 55% for definition 1, 44% for definition 2, 55% for definition 3, 33% for definition 4, 11% for definition 5, and 11% for definition 6. We observed a substantial incidence of transient elevations in PSA following combined external beam radiation and HDR brachytherapy for prostate cancer. Such elevations seem to be self-limited and should not trigger initiation of salvage therapies. No definition of failure was completely predictive

  9. SU-E-J-239: IMRT Planning of Prostate Cancer for a MRI-Linac Based On MRI Only

    Energy Technology Data Exchange (ETDEWEB)

    Chen, X; Prior, P; Paulson, E; Lawton, C; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2014-06-01

    Purpose: : To investigate dosimetric differences between MRI- and CT-based IMRT planning for prostate cancer, the impact of a magnetic field in a MRI-Linac, and to explore the feasibility of IMRT planning based on MRI alone. Methods: IMRT plans were generated based on CT and MRI images acquired on two representative prostate-cancer patients using clinical dose volume constraints. A research planning system (Monaco, Elekta), which employs a Monte Carlo dose engine and includes a perpendicular magnetic field of 1.5T from an MRI-Linac, was used. Bulk electron density assignments based on organ-specific values from ICRU 46 were used to convert MRI (T2) to pseudo CT. With the same beam configuration as in the original CT plan, 5 additional plans were generated based on CT or MRI, with or without optimization (i.e., just recalculation) and with or without the magnetic field. The plan quality in terms of commonly used dose volume (DV) parameters for all plans was compared. The statistical uncertainty on dose was < 1%. Results: For plans with the same contour set but without re-optimization, the DV parameters were different from those for the original CT plan, mostly less than 5% with a few exceptions. These differences were reduced to mostly less than 3% when the plans were re-optimized. For plans with contours from MRI, the differences in the DV parameters varied depending on the difference in the contours as compared to CT. For the optimized plans with contours from MR, the differences for PTV were less than 3%. Conclusion: The prostate IMRT plans based on MRI-only for a MR-Linac were practically similar as compared to the CT plan under the same beam and optimization configuration if the difference on the structure delineation is excluded, indicating the feasibility of using MRI-only for prostate IMRT.

  10. Diffusion-weighted MRI in prostatic lesions: Diagnostic performance of normalized ADC using normal peripheral prostatic zone as a reference

    Directory of Open Access Journals (Sweden)

    Tamer F. Taha Ali

    2018-03-01

    Full Text Available Aim of study: Evaluate the potential value of the normal peripheral zone as a reference organ to normalize prostatic lesion apparent diffusion coefficient (ADC to improve its evaluation of prostatic lesions. Patients and methods: This prospective study included 38 patients with clinical suspicion of cancer prostate (increased PSA levels (>4 ng/ml, hard prostate in digital rectal examination and who are scheduled to undergo a TRUS-guided biopsy. Conventional and DW-MRI was done and ADC was calculated. The normalized ADC value was calculated by dividing the ADC of lesion by ADC of reference site (healthy peripheral zone. DWI-MRI results were compared to the results of biopsy. Comparison of ADCs and nADCs of benign and malignant lesions was done. Receiver operating characteristics (ROC curve analysis was done. Results: The patients were classified by histopathology into non-malignant group (16 patients and malignant group (22 patients. Significant negative correlation between ADC and normalized ADC (nADC and malignancy was detected. There was no significant difference between the mean ADC of peripheral health prostatic zones (PZ between benign and malignant cases (2.221 ± 0.356 versus 1.99 ± 0.538x10−3 mm2/sec, p = 0.144.There was significant difference between the mean ADC and mean nADC in benign and malignant lesions (1.049 ± 0.217 versus 0.659 ± 0.221x10−3 mm2/sec, p < 0.001 and (0.475 ± 0.055 versus 0.328 ± 0.044, p < 0.001 respectively.There was significant higher diagnostic performance of nADC than ADC with ADC Cut-off value 0.75 × 10−3 mm2/sec and nADC cut-off value 0.39 could significantly differentiate between benign and malignant lesion with sensitivity, specificity, PPV,NPV of 86.36,75,82.61 and 80% respectively, p < 0.0001 for ADC and 95.45, 93.75, 95.45 and 93.75%, p < 0.0001 for nADC. Conclusion: diagnostic performance of nADC using normal peripheral zone is higher than

  11. The role of endorectal coil MRI in patient selection and treatment planning for prostate seed implants

    International Nuclear Information System (INIS)

    Clarke, Daniel H.; Banks, Stephen J.; Wiederhorn, A. Roger; Klousia, John W.; Lissy, Jeanne M.; Miller, Michelle; Able, Arnold M.; Artiles, Carlos; Hindle, William V.; Blair, Deborah N.; Houk, Russell R.; Sheridan, Michael J.

    2002-01-01

    Purpose: To assess the role of endorectal coil magnetic resonance imaging (MRI) staging for patients undergoing seed implantation (SI) with or without external beam radiotherapy (EBRT). Methods and Materials: Between October 1994 and December 1998, 390 patients underwent prostate SI (98% Pd-103, 2% I-125). Seventy-six percent of patients had a prostate serum antigen (PSA) 20. Ten percent of patients had a Gleason score (GS) of 4-5, 54% had GS 6, 29% had GS 7, and 7% had GS ≥ 8. Monotherapy was employed in 46% of patients, and the remaining 54% received combined EBRT and SI. Three hundred twenty-seven were staged by high-resolution phased array pelvic coil, or in most cases, an endorectal coil MRI. The MRI findings were used to guide stage-appropriate treatment recommendations, and to assist in the preplanning and optimization of seed distributions. The criteria utilized to determine MRI-based stage were founded on the reported literature from the University of Pennsylvania. All MRI studies were reviewed by C.A., D.B., or W.H., who were unaware of clinical stage at the time of their review. The biopsy report was available to them as the only clinical correlate. Results: Of the 327 patients staged by MRI, 70% were upstaged from the digital rectal examination-based clinical stage; 26% of T 1 , T 2 patients were upstaged to T 3 . Perineural invasion and the percentage of positive cores predicted for T 3 MRI stage (p 3 intermediate-risk group patients treated by combined therapy with a previous study of T 3 intermediate-risk group treated by radical prostatectomy (RP) at the University of Pennsylvania. Our 36-month PSA FFP was 94% compared with 21% for the previous study's RP patients. Conclusion: MRI is a valuable staging procedure for prostate cancer patients treated by SI. PSA FFP results appear to be improved by MRI staging. MRI T 3 disease can be treated more effectively by SI + EBRT than by RP

  12. TU-F-BRF-02: MR-US Prostate Registration Using Patient-Specific Tissue Elasticity Property Prior for MR-Targeted, TRUS-Guided HDR Brachytherapy

    International Nuclear Information System (INIS)

    Yang, X; Rossi, P; Ogunleye, T; Jani, A; Curran, W; Liu, T

    2014-01-01

    Purpose: High-dose-rate (HDR) brachytherapy has become a popular treatment modality for prostate cancer. Conventional transrectal ultrasound (TRUS)-guided prostate HDR brachytherapy could benefit significantly from MR-targeted, TRUS-guided procedure where the tumor locations, acquired from the multiparametric MRI, are incorporated into the treatment planning. In order to enable this integration, we have developed a MR-TRUS registration with a patient-specific biomechanical elasticity prior. Methods: The proposed method used a biomechanical elasticity prior to guide the prostate volumetric B-spline deformation in the MRI and TRUS registration. The patient-specific biomechanical elasticity prior was generated using ultrasound elastography, where two 3D TRUS prostate images were acquired under different probe-induced pressures during the HDR procedure, which takes 2-4 minutes. These two 3D TRUS images were used to calculate the local displacement (elasticity map) of two prostate volumes. The B-spline transformation was calculated by minimizing the Euclidean distance between the normalized attribute vectors of the prostate surface landmarks on the MR and TRUS. This technique was evaluated through two studies: a prostate-phantom study and a pilot study with 5 patients undergoing prostate HDR treatment. The accuracy of our approach was assessed through the locations of several landmarks in the post-registration and TRUS images; our registration results were compared with the surface-based method. Results: For the phantom study, the mean landmark displacement of the proposed method was 1.29±0.11 mm. For the 5 patients, the mean landmark displacement of the surface-based method was 3.25±0.51 mm; our method, 1.71±0.25 mm. Therefore, our proposed method of prostate registration outperformed the surfaced-based registration significantly. Conclusion: We have developed a novel MR-TRUS prostate registration approach based on patient-specific biomechanical elasticity prior

  13. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Fenster, Aaron; Ward, Aaron D

    2018-03-01

    Magnetic resonance imaging (MRI)-targeted, three-dimensional (3D) transrectal ultrasound (TRUS)-guided prostate biopsy aims to reduce the 21-47% false-negative rate of clinical two-dimensional (2D) TRUS-guided systematic biopsy, but continues to yield false-negative results. This may be improved via needle target optimization, accounting for guidance system errors and image registration errors. As an initial step toward the goal of optimized prostate biopsy targeting, we investigated how needle delivery error impacts tumor sampling probability for two targeting strategies. We obtained MRI and 3D TRUS images from 49 patients. A radiologist and radiology resident assessed these MR images and contoured 81 suspicious regions, yielding tumor surfaces that were registered to 3D TRUS. The biopsy system's root-mean-squared needle delivery error (RMSE) and systematic error were modeled using an isotropic 3D Gaussian distribution. We investigated two different prostate tumor-targeting strategies using (a) the tumor's centroid and (b) a ring in the lateral-elevational plane. For each simulation, targets were spaced at equal arc lengths on a ring with radius equal to the systematic error magnitude. A total of 1000 biopsy simulations were conducted for each tumor, with RMSE and systematic error magnitudes ranging from 1 to 6 mm. The difference in median tumor sampling probability and probability of obtaining a 50% core involvement was determined for ring vs centroid targeting. Our simulation results indicate that ring targeting outperformed centroid targeting in situations where systematic error exceeds RMSE. In these instances, we observed statistically significant differences showing 1-32% improvement in sampling probability due to ring targeting. Likewise, we observed statistically significant differences showing 1-39% improvement in 50% core involvement probability due to ring targeting. Our results suggest that the optimal targeting scheme for prostate biopsy depends on

  14. Evaluation of permanent I-125 prostate implants using radiographs and MRI

    International Nuclear Information System (INIS)

    Moerland, M.A.; Beersma, R.; Bhagwandien, R.; Wijrdeman, H.K.; Battermann, J.J.

    1995-01-01

    Introduction: Localized prostatic cancer is managed by radical prostatectomy, external beam irradiation or a permanent implant with I-125 seeds. Permanent implants are indicated for small tumours (T1-T2) with a well to moderate histological differentiation. The technique used is a transrectal ultrasound guided transperineal implantation technique, which aims for a seed and dose distribution such that the initial doserate line of 7.8 cGy/h encompasses the prostate resulting in an accumulated dose of 160 Gy. Up till now the seed and dose distribution is evaluated from isocentric radiographs, which do not show the relation with the prostate. Objectives: The aim of this study is the development of a technique to reconstruct and evaluate the seed and dose distribution within the prostate. Methods: Twenty patients underwent radiography on the simulator and scanning on a whole body NMR system within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the MR images provided the seed positions in relation to the prostate. Volume dose histograms were used to evaluate the implants. Results: The I-125 seeds and the prostate anatomy were well depicted on T1-weighted spin echo images with minimal read out gradient strength. To date, ten implants were evaluated. According to our method, the prostate volumes receiving the prescribed dose of 160 Gy ranged from 30 to 70% of the total prostate volumes. Conclusion: The combination of isocentric radiographs and MRI enables reconstruction of the seed and dose distribution in relation to the prostate and the computation of dose volume histograms, which may be of value in the evaluation of implant quality

  15. [Use of MRI before biopsy in diagnosis of prostate cancer: Single-operator study].

    Science.gov (United States)

    Bassard, S; Mege, J-L

    2015-12-01

    The diagnostic for prostate cancer is changing. To improve the detection of this cancer, urologists expect a lot from the contribution of magnetic resonance imaging (MRI). What is the role of this imaging in prostate cancer detection? This is a retrospective study, from 2011 to 2013, mono-centric and single-operator. Of the 464 needle biopsy of the prostate (BP), we excluded those with PSA>20 ng/mL or digital rectal examination (DRE)>T3. The remaining 430 BP were submitted or not to a 1.5 tesla MRI with pelvic antenna. The primary aim is the overall detection of prostate cancer. Secondary aim was the detection rate during the first series of BP and repeat BP, between the two groups in the MRI group. MRI and MRI without populations are comparable for age (63.3 vs 64.6), PSA (6.10 vs 6.13), DRE>T1c, prostate volume (55.4 cm(3) vs 51.7 cm(3)). There is no significant difference in overall detection between the two groups (P=0.12). There is no significant difference in cancer detection between the first BP (P=0.13) and the repeat BP (P=0.07). There is a significant difference in the early detection of BP MRI group (P=0.03) but not for the BP repeat MRI group (P=0.07). For 108 BP iterative MRI group, there were 67 BP targeted "mentally" with MRI: 18 cancers were detected, making a 25% detection rate. This study helps to highlight the value of MRI in the early rounds of BP but we can ask the value of this imaging during repeat biopsies. Targeted biopsies "mentally" do not have the expected detection sensitivity and seems to require a three-dimensional reconstruction to be more effective. 5. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

    International Nuclear Information System (INIS)

    Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M. III; Tempany, Clare M.; Cormack, Robert A.

    2012-01-01

    Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed

  17. Automated prostate cancer localization without the need for peripheral zone extraction using multiparametric MRI.

    Science.gov (United States)

    Liu, Xin; Yetik, Imam Samil

    2011-06-01

    Multiparametric magnetic resonance imaging (MRI) has been shown to have higher localization accuracy than transrectal ultrasound (TRUS) for prostate cancer. Therefore, automated cancer segmentation using multiparametric MRI is receiving a growing interest, since MRI can provide both morphological and functional images for tissue of interest. However, all automated methods to this date are applicable to a single zone of the prostate, and the peripheral zone (PZ) of the prostate needs to be extracted manually, which is a tedious and time-consuming job. In this paper, our goal is to remove the need of PZ extraction by incorporating the spatial and geometric information of prostate tumors with multiparametric MRI derived from T2-weighted MRI, diffusion-weighted imaging (DWI) and dynamic contrast enhanced MRI (DCE-MRI). In order to remove the need of PZ extraction, the authors propose a new method to incorporate the spatial information of the cancer. This is done by introducing a new feature called location map. This new feature is constructed by applying a nonlinear transformation to the spatial position coordinates of each pixel, so that the location map implicitly represents the geometric position of each pixel with respect to the prostate region. Then, this new feature is combined with multiparametric MR images to perform tumor localization. The proposed algorithm is applied to multiparametric prostate MRI data obtained from 20 patients with biopsy-confirmed prostate cancer. The proposed method which does not need the masks of PZ was found to have prostate cancer detection specificity of 0.84, sensitivity of 0.80 and dice coefficient value of 0.42. The authors have found that fusing the spatial information allows us to obtain tumor outline without the need of PZ extraction with a considerable success (better or similar performance to methods that require manual PZ extraction). Our experimental results quantitatively demonstrate the effectiveness of the proposed

  18. SU-E-J-228: MRI-Based Planning: Dosimetric Feasibility of Dose Painting for ADCDefined Intra-Prostatic Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, X; Dalah, E; Prior, P; Lawton, C; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-06-15

    Purpose: Apparent diffusion coefficient (ADC) map may help to delineate the gross tumor volume (GTV) in prostate gland. Dose painting with external beam radiotherapy for GTV might increase the local tumor control. The purpose of this study is to explore the maximum boosting dose on GTV using VMAT without sacrificing sparing of organs at risk (OARs) in MRI based planning. Methods: VMAT plans for 5 prostate patients were generated following the commonly used dose volume (DV) criteria based on structures contoured on T2 weighted MRI with bulk electron density assignment using electron densities derived from ICRU46. GTV for each patient was manually delineated based on ADC maps and fused to T2-weighted image set for planning study. A research planning system with Monte Carlo dose engine (Monaco, Elekta) was used to generate the VMAT plans with boosting dose on GTV gradually increased from 85Gy to 100Gy. DV parameters, including V(boosting-dose) (volume covered by boosting dose) for GTV, V75.6Gy for PTV, V45Gy, V70Gy, V72Gy and D1cc (Maximum dose to 1cc volume) for rectum and bladder, were used to measure plan quality. Results: All cases achieve at least 99.0% coverage of V(boosting-dose) on GTV and 95% coverage of V75.6Gy to the PTV. All the DV criteria, V45Gy≤50% and V70Gy≤15% for bladder and rectum, D1cc ≤77Gy (Rectum) and ≤80Gy (Bladder), V72Gy≤5% (rectum and bladder) were maintained when boosting GTV to 95Gy for all cases studied. Except for two patients, all the criteria were also met when the boosting dose goes to 100Gy. Conclusion: It is dosimetrically feasible safe to boost the dose to at least 95Gy to ADC defined GTV in prostate cancer using MRI guided VMAT delivery. Conclusion: It is dosimetrically feasible safe to boost the dose to at least 95Gy to ADC defined GTV in prostate cancer using MRI guided VMAT delivery. This research is partially supported by Elekta Inc.

  19. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bagla, Sandeep, E-mail: sandeep.bagla@gmail.com [Vascular Institute of Virginia, LLC (United States); Smirniotopoulos, John [New York Presbyterian Hospital/Weill Cornell Medical Center (United States); Orlando, Julie C.; Piechowiak, Rachel [Vascular Institute of Virginia, LLC (United States)

    2017-03-15

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  20. Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

    International Nuclear Information System (INIS)

    Bagla, Sandeep; Smirniotopoulos, John; Orlando, Julie C.; Piechowiak, Rachel

    2017-01-01

    PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm"2 vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

  1. Diffusion-weighted MRI of the prostate; Diffusionsgewichtete MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, U.G.; Scherr, M.K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Mueller-Lisse, U.L. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Klinik und Poliklinik fuer Urologie, Muenchen (Germany); Zamecnik, P.; Schlemmer, H.P.W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung fuer Radiologische Diagnostik, Heidelberg (Germany)

    2011-03-15

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [German] Die diffusionsgewichtete MRT (''diffusion-weighted imaging'', DWI) kann die MRT der Prostata bei der Erkennung und Lokalisation von Prostatakarzinomen besonders nach vorangehender, negativer Stanzbiopsie ergaenzen. In 13 klinischen Original- und 2 Uebersichtsarbeiten des Jahres 2010 zeigt sich, dass die DWI Prostatakarzinome an Einschraenkungen der freien Teilchenbeweglichkeit bei erhoehter Zelldichte qualitativ im Bild oder quantitativ an Hand des ''apparent diffusion coefficient'' (ADC) nachweist. Den ADC in der Prostata beeinflussen Staerke der Diffusionsgewichtung, Lokalisation (periphere Zone, Transitionalzone), Vorliegen von Prostatitis oder Einblutung sowie Streudichte und Differenzierung von Prostatakarzinomzellen. Unterschiede zwischen gesundem

  2. MRI target delineation may reduce long-term toxicity after prostate radiotherapy.

    Science.gov (United States)

    Sander, Lotte; Langkilde, Niels Christian; Holmberg, Mats; Carl, Jesper

    2014-06-01

    Aiming for minimal toxicity after radical prostate cancer (PC) radiotherapy (RT), magnetic resonance imaging (MRI) target delineation could be a possible benefit knowing that clinical target volumes (CTV) are up to 30% smaller, when CTV delineation on MRI is compared to standard computed tomography (CT). This study compares long-term toxicity using CT or MRI delineation before PC RT. Urinary and rectal toxicity assessments 36 months after image-guided RT (78 Gy) using CTC-AE scores in two groups of PC patients. Peak symptom score values were registered. One group of patients (n=72) had standard CT target delineation and gold markers as fiducials. Another group of patients (n=73) had MRI target delineation and a nickel-titanium stent as fiducial. At 36 months no difference in overall survival (92% in both groups, p=0.29) or in PSA-relapse free survival was found between the groups (MRI=89% and CT=94%, p=0.67). A significantly smaller CTV was found in the MRI group (p=0.02). Urinary retention and frequency were significantly reduced in the MRI group (p=0.03 in the matter of both). The overall urinary and rectal toxicity did not differ between the two groups. MRI delineation leads to a significantly reduced CTV. Significantly lower urinary frequency and urinary retention toxicity scores were observed following MRI delineation. The study did not find significant differences in overall urinary or rectal toxicity between the two groups. PSA-relapse survival did not differ between the two groups at 36 months.

  3. [Application evaluation of multi-parametric MRI in the diagnosis and differential diagnosis of early prostate cancer and prostatitis].

    Science.gov (United States)

    Li, P; Huang, Y; Li, Y; Cai, L; Ji, G H; Zheng, Y; Chen, Z Q

    2016-10-11

    Objective: To evaluate the value of multi-parametric MRI (Mp-MRI) in the diagnosis and differential diagnosis of early prostate cancer(PCa) in the peripheral zone(PZ) and low T 2 WI signal intensity of prostatitis. Methods: A total of 40 patients with PZ early PCa and 37 with prostatitis of hypointense T 2 WI signal in PZ were retrospectively analyzed, which were collected from the General Hospital of Ningxia Medical University from Janurary 2009 to June 2015, who underwent T 2 WI, DWI, and DCE-MRI examination and all patients were confirmed by pathology. All the data was transferred to GE Advanced Workstation AW4.3, the indexes divided into cancerous and prostatitis regions were calculated by Functool2 of signal intensity-time(SI-T) curve and ADC value, to calcuate the time to minimum(T max ), the whole enhancment degree (SI max ). ROC cure was used to determine the cutoff value for PCa detection with the ADC value. Result: On T 2 WI, 57.5% of PCa (23/40) showed focal nodular homogeneous low signal intensity, 70.3% of prostatitis(26/37) showed diffuse inhomogeneous low signal intensity. DCE-MRI, the distribution of curve types for malignant tumors was type Ⅰ 2.5%(1/40), typeⅡ32.5%(13/40) and type Ⅲ 65.0% (26/40). While the numbers for prostatitis was type Ⅰ 16.2%(6/37) , type Ⅱ 56.8% (21/37) and type Ⅲ 27.0% (10/37)respectively.The patterns of curve types in malignant lesions were different from benign lesions significantly(χ 2 =12.32, P prostatitis regions were (17.96±2.91)s, 1.76%±0.23% and (21.19±3.59)s, 1.53%±0.18%, respectively ( t =5.37, 6.10; P prostatitis regions were (0.95±0.13)×10 -3 mm 2 /s and (1.12±0.13)×10 -3 mm 2 /s, respectively ( t =7.10, P prostatitis from early PCa.

  4. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  5. Multi-parametric MRI findings of granulomatous prostatitis developing after intravesical bacillus calmette-guérin therapy.

    Science.gov (United States)

    Gottlieb, Josh; Princenthal, Robert; Cohen, Martin I

    2017-07-01

    To evaluate the multi-parametric MRI (mpMRI) findings in patients with biopsy-proven granulomatous prostatitis and prior Bacillus Calmette-Guérin (BCG) exposure. MRI was performed in six patients with pathologically proven granulomatous prostatitis and a prior history of bladder cancer treated with intravesical BCG therapy. Multi-parametric prostate MRI images were recorded on a GE 750W or Philips Achieva 3.0 Tesla MRI scanner with high-resolution, small-field-of-view imaging consisting of axial T2, axial T1, coronal T2, sagittal T2, axial multiple b-value diffusion (multiple values up to 1200 or 1400), and dynamic contrast-enhanced 3D axial T1 with fat suppression sequence. Two different patterns of MR findings were observed. Five of the six patients had a low mean ADC value prostatitis. The other pattern seen in one of the six patients was decreased signal on the ADC map images with increased signal on the high-b-value sequence, revealing true restricted diffusion indistinguishable from aggressive prostate cancer. This patient had biopsy-confirmed acute BCG prostatitis. Our study suggests that patients with known BCG exposure and PI-RADS v2 scores ≤3, showing similar mpMRI findings as demonstrated, may not require prostate biopsy.

  6. Clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1996-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from MRI study were reconstructed to match precisely the corresponding CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also scrutinized. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair of comparison. The patient study showed mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI respectively (Fig. 1). The difference in prostate location with the two studies most commonly differed at the base and at the apex of the prostate (Fig. 2). On transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone (Fig. 3). Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. In view of excellent treatment results obtained with current CT localization of the prostate, still it may not be wise to reduce target volume to that demonstrated on MRI

  7. Optimal high b-value for diffusion weighted MRI in diagnosing high risk prostate cancers in the peripheral zone.

    Science.gov (United States)

    Agarwal, Harsh K; Mertan, Francesca V; Sankineni, Sandeep; Bernardo, Marcelino; Senegas, Julien; Keupp, Jochen; Daar, Dagane; Merino, Maria; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris

    2017-01-01

    To retrospectively determine the optimal b-value(s) of diffusion-weighted imaging (DWI) associated with intermediate-high risk cancer in the peripheral zone (PZ) of the prostate. Forty-two consecutive patients underwent multi b-value (16 evenly spaced b-values between 0 and 2000 s/mm 2 ) DWI along with multi-parametric MRI (MP-MRI) of the prostate at 3 Tesla followed by trans-rectal ultrasound/MRI fusion guided targeted biopsy of suspicious lesions detected at MP-MRI. Computed DWI images up to a simulated b-value of 4000 s/mm 2 were also obtained using a pair of b-values (b = 133 and 400 or 667 or 933 s/mm 2 ) from the multi b-value DWI. The contrast ratio of average intensity of the targeted lesions and the background PZ was determined. Receiver operator characteristic curves and the area under the curve (AUCs) were obtained for separating patients eligible for active surveillance with low risk prostate cancers from intermediate-high risk prostate cancers as per the cancer of the prostate risk assessment (CAPRA) scoring system. The AUC first increased then decreased with the increase in b-values reaching maximum at b = 1600 s/mm 2 (0.74) with no statistically significant different AUC of DWI with b-values 1067-2000 s/mm 2 . The AUC of computed DWI increased then decreased with the increase in b-values reaching a maximum of 0.75 around b = 2000 s/mm 2 . There was no statistically significant difference between the AUC of optimal acquired DWI and either of optimal computed DWI. The optimal b-value for acquired DWI in differentiating intermediate-high from low risk prostate cancers in the PZ is b = 1600 s/mm 2 . The computed DWI has similar performance as that of acquired DWI with the optimal performance around b = 2000 s/mm 2 . 4 J. Magn. Reson. Imaging 2017;45:125-131. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Optimal MRI sequences for 68Ga-PSMA-11 PET/MRI in evaluation of biochemically recurrent prostate cancer.

    Science.gov (United States)

    Lake, Spencer T; Greene, Kirsten L; Westphalen, Antonio C; Behr, Spencer C; Zagoria, Ronald; Small, Eric J; Carroll, Peter R; Hope, Thomas A

    2017-09-19

    PET/MRI can be used for the detection of disease in biochemical recurrence (BCR) patients imaged with 68 Ga-PSMA-11 PET. This study was designed to determine the optimal MRI sequences to localize positive findings on 68 Ga-PSMA-11 PET of patients with BCR after definitive therapy. Fifty-five consecutive prostate cancer patients with BCR imaged with 68 Ga-PSMA-11 3.0T PET/MRI were retrospectively analyzed. Mean PSA was 7.9 ± 12.9 ng/ml, and mean PSA doubling time was 7.1 ± 6.6 months. Detection rates of anatomic correlates for prostate-specific membrane antigen (PSMA)-positive foci were evaluated on small field of view (FOV) T2, T1 post-contrast, and diffusion-weighted images. For prostate bed recurrences, the detection rate of dynamic contrast-enhanced (DCE) imaging for PSMA-positive foci was evaluated. Finally, the detection sensitivity for PSMA-avid foci on 3- and 8-min PET acquisitions was compared. PSMA-positive foci were detected in 89.1% (49/55) of patients evaluated. Small FOV T2 performed best for lymph nodes and detected correlates for all PSMA-avid lymph nodes. DCE imaging performed the best for suspected prostate bed recurrence, detecting correlates for 87.5% (14/16) of PSMA-positive prostate bed foci. The 8-min PET acquisition performed better than the 3-min acquisition for lymph nodes smaller than 1 cm, detecting 100% (57/57) of lymph nodes less than 1 cm, compared to 78.9% (45/57) for the 3-min acquisition. PSMA PET/MRI performed well for the detection of sites of suspected recurrent disease in patients with BCR. Of the MRI sequences obtained for localization, small FOV T2 images detected the greatest proportion of PSMA-positive abdominopelvic lymph nodes and DCE imaging detected the greatest proportion of PSMA-positive prostate bed foci. The 8-min PET acquisition was superior to the 3 min acquisition for detection of small lymph nodes.

  9. MRI to predict prostate growth and development in children, adolescents and young adults

    International Nuclear Information System (INIS)

    Ren, Jing; Liu, Huijia; Wen, Didi; Huang, Xufang; Ren, Fang; Huan, Yi; Wang, He

    2015-01-01

    The purpose of this study was to investigate the use of MRI in predicting prostate growth and development. A total of 1,500 healthy male volunteers who underwent MRI of the pelvis were included in this prospective study. Subjects were divided into five groups according to age (group A, 2-5 years; group B, 6-10 years; group C, 11-15 years; group D, 16-20 years; group E, 21-25 years). Total prostate volume (TPV) as well as prostate central zone (CZ) and peripheral zone (PZ) were measured and evaluated on MRI. Data of the different groups were compared using variance analysis, Scheffe's method, Kruskal-Wallis H-test, and Pearson's correlation. Statistical significance was inferred at P 3 , 0.05 cm 3 , 2.83 cm 3 , 8.32 cm 3, and 11.56 cm 3 , respectively, and the median prostate development scores were 0.08, 0.69, 1.56, 2.38, and 2.74, respectively. Both TPVs and zonal anatomy scores varied significantly among the five groups (P = 0.000). TPV and zonal anatomy score increased with increasing age. MRI provides a reliable quantitative reference for prostate growth and development. (orig.)

  10. Dynamic contrast-enhanced MRI of the prostate. Comparison of two different post-processing algorithms

    International Nuclear Information System (INIS)

    Beyersdorff, Dirk; Franiel, T.; Luedemann, L.; Dietz, E.; Galler, D.; Marchot, P.

    2011-01-01

    Purpose: To evaluate the usefulness of a commercially available post-processing software tool for detecting prostate cancer on dynamic contrast-enhanced magnetic resonance imaging (MRI) and to compare the results to those obtained with a custom-made post-processing algorithm already tested under clinical conditions. Materials and Methods: Forty-eight patients with proven prostate cancer were examined by standard MRI supplemented by dynamic contrast-enhanced dual susceptibility contrast (DCE-DSC) MRI prior to prostatectomy. A custom-made post-processing algorithm was used to analyze the MRI data sets and the results were compared to those obtained using a post-processing algorithm from Invivo Corporation (Dyna CAD for Prostate) applied to dynamic T 1-weighted images. Histology was used as the gold standard. Results: The sensitivity for prostate cancer detection was 78 % for the custom-made algorithm and 60 % for the commercial algorithm and the specificity was 79 % and 82 %, respectively. The accuracy was 79 % for our algorithm and 77.5 % for the commercial software tool. The chi-square test (McNemar-Bowker test) yielded no significant differences between the two tools (p = 0.06). Conclusion: The two investigated post-processing algorithms did not differ in terms of prostate cancer detection. The commercially available software tool allows reliable and fast analysis of dynamic contrast-enhanced MRI for the detection of prostate cancer. (orig.)

  11. Tumorsize dependent detection rate of endorectal MRI of prostate cancer-A histopathologic correlation with whole-mount sections in 70 patients with prostate cancer

    International Nuclear Information System (INIS)

    Roethke, Matthias C.; Lichy, Matthias P.; Jurgschat, Leo; Hennenlotter, Joerg; Vogel, Ulrich; Schilling, David; Stenzl, Arnulf; Claussen, Claus D.; Schlemmer, Heinz-Peter

    2011-01-01

    Purpose: To evaluate the value of T2w endorectal MRI (eMRI) for correct detection of tumor foci within the prostate regarding tumor size. Materials and Methods: 70 patients with histologically proven prostate cancer were examined with T2w eMRI before radical prostatectomy at a 1.5 T scanner. For evaluation of eMRI, two radiologists evaluated each tumor focus within the gland. After radical prostatectomy, the prostates were prepared as whole-mount sections, according to transversal T2w eMRI. For each slice, tumor surroundings were marked and compared with eMRI. Based on whole-mount section, 315 slices were evaluated and 533 tumor lesions were documented. Results: Based on the T2w eMRI, 213 tumor lesions were described. In 137/213, histology could prove these lesions. EMRI was able to visualize 0/56 lesions with a maximum size of 2 cm 50/56 (89%). False positive eMRI findings were: 2 cm n = 2. Conclusion: T2w eMRI cannot exclude prostate cancer with lesions smaller 10 mm and 0.4 cm 3 respectively. The detection rate for lesions more than 20 mm (1.6 cm 3 ) is to be considered as high.

  12. Interobserver Delineation variation using CT versus combined CT + MRI in intensity- modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Villeirs, G.M.; Verstraete, K.L.; Vaerenbergh, K. van; Vakaet, L.; Bral, S.; Claus, F.; Neve, W.J. de; Meerleer, G.O. de

    2005-01-01

    Purpose: to quantify interobserver variation of prostate and seminal vesicle delineations using CT only versus CT + MRI in consensus reading with a radiologist. Material and methods: the prostate and seminal vesicles of 13 patients treated with intensity-modulated radiotherapy for prostatic adenocarcinoma were retrospectively delineated by three radiation oncologists on CT only and on CT + MRI in consensus reading with a radiologist. The volumes and margin positions were calculated and intermodality and interobserver variations were assessed for the clinical target volume (CTV), seminal vesicles, prostate and three prostatic subdivisions (apical, middle and basal third). Results: using CT + MRI as compared to CT alone, the mean CTV, prostate and seminal vesicle volumes significantly decreased by 6.54%, 5.21% and 10.47%, respectively. More importantly, their standard deviations significantly decreased by 63.06%, 62.65% and 44.83%, respectively. The highest level of variation was found at the prostatic apex, followed by the prostatic base and seminal vesicles. Conclusion: addition of MRI to CT in consensus reading with a radiologist results in a moderate decrease of the CTV, but an important decrease of the interobserver delineation variation, especially at the prostatic apex. (orig.)

  13. The Role of MRI in Prostate Cancer Active Surveillance

    Directory of Open Access Journals (Sweden)

    Linda M. Johnson

    2014-01-01

    Full Text Available Prostate cancer is the most common cancer diagnosis in American men, excluding skin cancer. The clinical behavior of prostate cancer varies from low-grade, slow growing tumors to high-grade aggressive tumors that may ultimately progress to metastases and cause death. Given the high incidence of men diagnosed with prostate cancer, conservative treatment strategies such as active surveillance are critical in the management of prostate cancer to reduce therapeutic complications of radiation therapy or radical prostatectomy. In this review, we will review the role of multiparametric MRI in the selection and follow-up of patients on active surveillance.

  14. Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning

    DEFF Research Database (Denmark)

    Arabi, H.; Koutsouvelis, N.; Rouzaud, M.

    2016-01-01

    Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial t......-CT images from conventional Dixon MRI sequences with improved bone extraction accuracy. The approach is promising for potential use in PET AC and MRI-only or hybrid PET/MRI-guided RT treatment planning. © 2016 Institute of Physics and Engineering in Medicine.......Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial...... the conventional MRI segmentation technique and a recently proposed multi-atlas approach. The clinical studies consisted of pelvic CT, PET and MRI scans of 12 patients with loco-regionally advanced rectal disease. In the first step, bone segmentation of the target image is optimized through local weighted atlas...

  15. Incorporating Oxygen-Enhanced MRI into Multi-Parametric Assessment of Human Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Heling Zhou

    2017-08-01

    Full Text Available Hypoxia is associated with prostate tumor aggressiveness, local recurrence, and biochemical failure. Magnetic resonance imaging (MRI offers insight into tumor pathophysiology and recent reports have related transverse relaxation rate (R2* and longitudinal relaxation rate (R1 measurements to tumor hypoxia. We have investigated the inclusion of oxygen-enhanced MRI for multi-parametric evaluation of tumor malignancy. Multi-parametric MRI sequences at 3 Tesla were evaluated in 10 patients to investigate hypoxia in prostate cancer prior to radical prostatectomy. Blood oxygen level dependent (BOLD, tissue oxygen level dependent (TOLD, dynamic contrast enhanced (DCE, and diffusion weighted imaging MRI were intercorrelated and compared with the Gleason score. The apparent diffusion coefficient (ADC was significantly lower in tumor than normal prostate. Baseline R2* (BOLD-contrast was significantly higher in tumor than normal prostate. Upon the oxygen breathing challenge, R2* decreased significantly in the tumor tissue, suggesting improved vascular oxygenation, however changes in R1 were minimal. R2* of contralateral normal prostate decreased in most cases upon oxygen challenge, although the differences were not significant. Moderate correlation was found between ADC and Gleason score. ADC and R2* were correlated and trends were found between Gleason score and R2*, as well as maximum-intensity-projection and area-under-the-curve calculated from DCE. Tumor ADC and R2* have been associated with tumor hypoxia, and thus the correlations are of particular interest. A multi-parametric approach including oxygen-enhanced MRI is feasible and promises further insights into the pathophysiological information of tumor microenvironment.

  16. Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1997-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from the MRI study were reconstructed to precisely match the CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also estimated. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair in comparison. The patient study showed a mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI, respectively. The difference in prostate location with the two studies usually differed at the base and at the apex of the prostate. On the transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone. Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. CT-MRI image fusion technique provides valuable supplements to CT technology for more precise targeting of the prostate cancer

  17. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  18. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F.; Bretschneider, T.; Hartwig, T.; Disch, A.C.

    2014-01-01

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  19. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results.

    Science.gov (United States)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R; Scheenen, Tom W; Bathen, Tone F; Selnæs, Kirsten M

    2017-07-01

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K trans and V e ) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p textural features correlated insignificantly with K trans and V e . GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K trans , and V e . The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. • T2W MRI-derived textural features correlate significantly with Gleason score and ADC. • T2W MRI-derived textural features differentiate Gleason score 3+4 from 4+3 cancers. • T2W image textural features could augment tumour characterization.

  20. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Scheenen, Tom W. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Bathen, Tone F.; Selnaes, Kirsten M. [NTNU, Norwegian University of Science and Technology, Department of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); St. Olavs Hospital, Trondheim University Hospital, Trondheim (Norway)

    2017-07-15

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K{sup trans} and V{sub e}) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p < 0.05) with both GS and median ADC. Contrast correlated moderately with median ADC. The textural features correlated insignificantly with K{sup trans} and V{sub e}. GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K{sup trans}, and V{sub e}. The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. (orig.)

  1. Prostate MRI findings in patients treated for testosterone deficiency while on active surveillance for low-risk prostate cancer

    Science.gov (United States)

    Hashimoto, Takeshi; Rahul, Krishnan; Takeda, Toshikazu; Benfante, Nicole; Mulhall, John P.; Hricak, Hedvig; Eastham, James A.; Vargas, Hebert Alberto

    2017-01-01

    Objective To investigate the multiparametric prostate magnetic resonance imaging (mpMRI) findings in patients treated with testosterone replacement therapy (TRT) while on active surveillance (AS) for low-risk prostate cancer. Methods We retrospectively reviewed 12 patients who underwent mpMRI before and after TRT while on AS. Changes in serum testosterone level, prostate specific antigen (PSA), prostate biopsy findings, prostate volume and Prostate Imaging Reporting and Data System Version 2 (PI-RADSv2) score before and after TRT were summarized. Results Following TRT, there was a significant increase in serum testosterone (516.5 ng/dl vs. 203.0 ng/dl), PSA (4.2 ng/ml vs. 3.3 ng/ml) and prostate volume (55.2 cm3 vs. 39.4 cm3). Two patients had biopsy progression during the study periods. The PI-RADSv2 scores before and after TRT were unchanged in 10/12 patients; none of these demonstrated biopsy progression on post TRT. The PI-RADSv2 scores increased after TRT in 2/12 patients; both showed Gleason score upgrade on follow-up biopsy. One of these two patients underwent radical treatment due to clinical progression. The area under the curve calculated from PI-RADSv2 score after TRT was 0.90, which was better than that calculated from post TRT PSA level (0.48). Conclusions After TRT, mpMRI findings remained stable in patients without biopsy progression, while PI-RADSv2 score increase was identified in patients with Gleason score upgrade on follow-up biopsy. PMID:27665357

  2. Combined 18F-Fluciclovine PET/MRI Shows Potential for Detection and Characterization of High-Risk Prostate Cancer.

    Science.gov (United States)

    Elschot, Mattijs; Selnæs, Kirsten M; Sandsmark, Elise; Krüger-Stokke, Brage; Størkersen, Øystein; Giskeødegård, Guro F; Tessem, May-Britt; Moestue, Siver A; Bertilsson, Helena; Bathen, Tone F

    2018-05-01

    The objective of this study was to investigate whether quantitative imaging features derived from combined 18 F-fluciclovine PET/multiparametric MRI show potential for detection and characterization of primary prostate cancer. Methods: Twenty-eight patients diagnosed with high-risk prostate cancer underwent simultaneous 18 F-fluciclovine PET/MRI before radical prostatectomy. Volumes of interest (VOIs) for prostate tumors, benign prostatic hyperplasia (BPH) nodules, prostatitis, and healthy tissue were delineated on T2-weighted images, using histology as a reference. Tumor VOIs were marked as high-grade (≥Gleason grade group 3) or not. MRI and PET features were extracted on the voxel and VOI levels. Partial least-squared discriminant analysis (PLS-DA) with double leave-one-patient-out cross-validation was performed to distinguish tumors from benign tissue (BPH, prostatitis, or healthy tissue) and high-grade tumors from other tissue (low-grade tumors or benign tissue). The performance levels of PET, MRI, and combined PET/MRI features were compared using the area under the receiver-operating-characteristic curve (AUC). Results: Voxel and VOI features were extracted from 40 tumor VOIs (26 high-grade), 36 BPH VOIs, 6 prostatitis VOIs, and 37 healthy-tissue VOIs. PET/MRI performed better than MRI and PET alone for distinguishing tumors from benign tissue (AUCs of 87%, 81%, and 83%, respectively, at the voxel level and 96%, 93%, and 93%, respectively, at the VOI level) and high-grade tumors from other tissue (AUCs of 85%, 79%, and 81%, respectively, at the voxel level and 93%, 93%, and 91%, respectively, at the VOI level). T2-weighted MRI, diffusion-weighted MRI, and PET features were the most important for classification. Conclusion: Combined 18 F-fluciclovine PET/multiparametric MRI shows potential for improving detection and characterization of high-risk prostate cancer, in comparison to MRI and PET alone. © 2018 by the Society of Nuclear Medicine and Molecular

  3. Synchronous rectal and prostate cancer – The impact of MRI on incidence and imaging findings

    International Nuclear Information System (INIS)

    Sturludóttir, Margrét; Martling, Anna; Carlsson, Stefan; Blomqvist, Lennart

    2015-01-01

    Highlights: •Prostate and rectal cancers are two of the most common cancers in male. •Synchronous diagnosis of prostate and rectal cancer is a rare identity. •Strong increase in the synchronous diagnosis likely due to improved diagnostic methods. •Pre-treatment MRI for rectal cancer has led to increased synchronous diagnosis. -- Abstract: Objective: To evaluate the incidence of synchronous diagnosis of rectal and prostate cancer and to identify how the role of magnetic resonance imaging (MRI) for preoperative staging of rectal cancer has affected the incidence. Methods: Regional data from the Swedish Colorectal Cancer Registry and the Regional Cancer Registry in Stockholm-Gotland area (two million inhabitants) between the years 1995–2011 were used. Patients were included when the rectal cancer was diagnosed prior to the prostate cancer. Medical records and pre-treatment MRI were retrospectively reviewed. Results: Of 29,849 patients diagnosed with either disease, synchronous diagnosis was made in 29 patients (0.1%). Two patients were diagnosed in the years 1995–1999, seven patients between the years 2000–2005 and 20 patients between the years 2006–2011. The most common presentation, for the prostate cancer was incidental finding during staging for rectal cancer, n = 20, and of those led MRI to the diagnosis in 14 cases. At retrospective review, all patients had focal lesions in the prostate on MRI and patients with higher suspicion of malignancy on MRI had more locally advanced disease. Conclusion: Synchronous rectal and prostate cancer are a rare entity, but a strong increase in synchronous diagnosis is seen which may be attributed to improved diagnostic methods, including the use of pre-treatment MRI in routine work-up for rectal cancer

  4. Synchronous rectal and prostate cancer – The impact of MRI on incidence and imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Sturludóttir, Margrét, E-mail: margret.sturludottir@karolinska.se [Department of Radiology, Karolinska University Hospital, 17176 Solna (Sweden); Martling, Anna, E-mail: anna.martling@ki.se [Center of Surgical Gastroenterology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden); Carlsson, Stefan, E-mail: stefan.carlsson@ki.se [Department of Urology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden); Blomqvist, Lennart, E-mail: lennart.k.blomqvist@ki.se [Department of Radiology, Karolinska University Hospital, 17176 Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, 17177 Solna (Sweden)

    2015-04-15

    Highlights: •Prostate and rectal cancers are two of the most common cancers in male. •Synchronous diagnosis of prostate and rectal cancer is a rare identity. •Strong increase in the synchronous diagnosis likely due to improved diagnostic methods. •Pre-treatment MRI for rectal cancer has led to increased synchronous diagnosis. -- Abstract: Objective: To evaluate the incidence of synchronous diagnosis of rectal and prostate cancer and to identify how the role of magnetic resonance imaging (MRI) for preoperative staging of rectal cancer has affected the incidence. Methods: Regional data from the Swedish Colorectal Cancer Registry and the Regional Cancer Registry in Stockholm-Gotland area (two million inhabitants) between the years 1995–2011 were used. Patients were included when the rectal cancer was diagnosed prior to the prostate cancer. Medical records and pre-treatment MRI were retrospectively reviewed. Results: Of 29,849 patients diagnosed with either disease, synchronous diagnosis was made in 29 patients (0.1%). Two patients were diagnosed in the years 1995–1999, seven patients between the years 2000–2005 and 20 patients between the years 2006–2011. The most common presentation, for the prostate cancer was incidental finding during staging for rectal cancer, n = 20, and of those led MRI to the diagnosis in 14 cases. At retrospective review, all patients had focal lesions in the prostate on MRI and patients with higher suspicion of malignancy on MRI had more locally advanced disease. Conclusion: Synchronous rectal and prostate cancer are a rare entity, but a strong increase in synchronous diagnosis is seen which may be attributed to improved diagnostic methods, including the use of pre-treatment MRI in routine work-up for rectal cancer.

  5. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  6. Percutaneous MR-guided focal cryoablation for recurrent prostate cancer following radiation therapy. Retrospective analysis of iceball margins and outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Overduin, Christiaan G.; Jenniskens, Sjoerd F.M.; Bomers, Joyce G.R. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Sedelaar, J.P.M. [Radboud University Medical Center, Department of Urology, Nijmegen (Netherlands); Fuetterer, Jurgen J. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Engineering and Technical Medicine, Enschede (Netherlands)

    2017-11-15

    To evaluate iceball margins after magnetic resonance (MR)-guided focal salvage prostate cryoablation and determine the correlation with local outcome. A retrospective review was performed on 47 patients that underwent percutaneous MR-guided focal cryoablation for biopsy-proven locally recurrent prostate cancer after primary radiotherapy. Preprocedural diagnostic and intraprocedural MR images were analysed to derive three-directional iceball margins. Local tumour progression after cryoablation was defined as evident tumour recurrence on follow-up MRI, positive MR-guided biopsy or biochemical failure without radiological evidence of metastatic disease. Mean iceball margins were 8.9 mm (range -7.1 to 16.2), 10.1 mm (range 1.1-20.3) and 12.5 mm (range -1.5 to 22.2) in anteroposterior, left-right and craniocaudal direction respectively. Iceball margins were significantly smaller for tumours that were larger (P =.008) or located in the posterior gland (P =.047). Significantly improved local progression-free survival at 1 year post focal cryoablation was seen between patients with iceball margin >10 mm (100%), 5-10 mm (84%) and <5 mm (15%) (P <.001). Iceball margins appear to correlate with local outcome following MR-guided focal salvage prostate cryoablation. Our initial data suggest that freezing should be applied at minimum 5 mm beyond the border of an MR-visible recurrent prostate tumour for successful ablation, with a wider margin appearing desirable. (orig.)

  7. Novel PCA-VIP scheme for ranking MRI protocols and identifying computer-extracted MRI measurements associated with central gland and peripheral zone prostate tumors.

    Science.gov (United States)

    Ginsburg, Shoshana B; Viswanath, Satish E; Bloch, B Nicolas; Rofsky, Neil M; Genega, Elizabeth M; Lenkinski, Robert E; Madabhushi, Anant

    2015-05-01

    To identify computer-extracted features for central gland and peripheral zone prostate cancer localization on multiparametric magnetic resonance imaging (MRI). Preoperative T2-weighted (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) MRI were acquired from 23 men with confirmed prostate cancer. Following radical prostatectomy, the cancer extent was delineated by a pathologist on ex vivo histology and mapped to MRI by nonlinear registration of histology and corresponding MRI slices. In all, 244 computer-extracted features were extracted from MRI, and principal component analysis (PCA) was employed to reduce the data dimensionality so that a generalizable classifier could be constructed. A novel variable importance on projection (VIP) measure for PCA (PCA-VIP) was leveraged to identify computer-extracted MRI features that discriminate between cancer and normal prostate, and these features were used to construct classifiers for cancer localization. Classifiers using features selected by PCA-VIP yielded an area under the curve (AUC) of 0.79 and 0.85 for peripheral zone and central gland tumors, respectively. For tumor localization in the central gland, T2w, DCE, and DWI MRI features contributed 71.6%, 18.1%, and 10.2%, respectively; for peripheral zone tumors T2w, DCE, and DWI MRI contributed 29.6%, 21.7%, and 48.7%, respectively. PCA-VIP identified relatively stable subsets of MRI features that performed well in localizing prostate cancer on MRI. © 2014 Wiley Periodicals, Inc.

  8. Concurrent segmentation of the prostate on MRI and CT via linked statistical shape models for radiotherapy planning

    International Nuclear Information System (INIS)

    Chowdhury, Najeeb; Toth, Robert; Chappelow, Jonathan; Kim, Sung; Motwani, Sabin; Punekar, Salman; Lin Haibo; Both, Stefan; Vapiwala, Neha; Hahn, Stephen; Madabhushi, Anant

    2012-01-01

    Purpose: Prostate gland segmentation is a critical step in prostate radiotherapy planning, where dose plans are typically formulated on CT. Pretreatment MRI is now beginning to be acquired at several medical centers. Delineation of the prostate on MRI is acknowledged as being significantly simpler to perform, compared to delineation on CT. In this work, the authors present a novel framework for building a linked statistical shape model (LSSM), a statistical shape model (SSM) that links the shape variation of a structure of interest (SOI) across multiple imaging modalities. This framework is particularly relevant in scenarios where accurate boundary delineations of the SOI on one of the modalities may not be readily available, or difficult to obtain, for training a SSM. In this work the authors apply the LSSM in the context of multimodal prostate segmentation for radiotherapy planning, where the prostate is concurrently segmented on MRI and CT. Methods: The framework comprises a number of logically connected steps. The first step utilizes multimodal registration of MRI and CT to map 2D boundary delineations of the prostate from MRI onto corresponding CT images, for a set of training studies. Hence, the scheme obviates the need for expert delineations of the gland on CT for explicitly constructing a SSM for prostate segmentation on CT. The delineations of the prostate gland on MRI and CT allows for 3D reconstruction of the prostate shape which facilitates the building of the LSSM. In order to perform concurrent prostate MRI and CT segmentation using the LSSM, the authors employ a region-based level set approach where the authors deform the evolving prostate boundary to simultaneously fit to MRI and CT images in which voxels are classified to be either part of the prostate or outside the prostate. The classification is facilitated by using a combination of MRI-CT probabilistic spatial atlases and a random forest classifier, driven by gradient and Haar features

  9. SU-F-BRF-10: Deformable MRI to CT Validation Employing Same Day Planning MRI for Surrogate Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Padgett, K; Stoyanova, R; Johnson, P; Dogan, N; Pollack, A [University of Miami School of Medicine, Miami, FL (United States); Piper, J; Javorek, A [MIM Software, Inc., Beachwood, OH (United States)

    2014-06-15

    for multi-modality comparisons which are inherently more challenging. Deformable registrations generated in this work significantly outperformed rigid alignments. Research reported in this abstract was supported by the NIH National Cancer Institute R21CA153826 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer” and Bankhead-Coley Cancer Research Program 10BT-03 “MRI-Guided Radiotherapy and Biomarkers for Prostate Cancer”.

  10. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  11. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  12. Comparative sensitivities of functional MRI sequences in detection of local recurrence of prostate carcinoma after radical prostatectomy or external-beam radiotherapy.

    Science.gov (United States)

    Roy, Catherine; Foudi, Fatah; Charton, Jeanne; Jung, Michel; Lang, Hervé; Saussine, Christian; Jacqmin, Didier

    2013-04-01

    The aim of this retrospective study was to determine the respective accuracies of three types of functional MRI sequences-diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) MRI, and 3D (1)H-MR spectroscopy (MRS)-in the depiction of local prostate cancer recurrence after two different initial therapy options. From a cohort of 83 patients with suspicion of local recurrence based on prostate-specific antigen (PSA) kinetics who were imaged on a 3-T MRI unit using an identical protocol including the three functional sequences with an endorectal coil, we selected 60 patients (group A, 28 patients who underwent radical prostatectomy; group B, 32 patients who underwent external-beam radiation) who had local recurrence ascertained on the basis of a transrectal ultrasound-guided biopsy results and a reduction in PSA level after salvage therapy. All patients presented with a local relapse. Sensitivity with T2-weighted MRI and 3D (1)H-MRS sequences was 57% and 53%, respectively, for group A and 71% and 78%, respectively, for group B. DCE-MRI alone showed a sensitivity of 100% and 96%, respectively, for groups A and B. DWI alone had a higher sensitivity for group B (96%) than for group A (71%). The combination of T2-weighted imaging plus DWI plus DCE-MRI provided a sensitivity as high as 100% in group B. The performance of functional imaging sequences for detecting recurrence is different after radical prostatectomy and external-beam radiotherapy. DCE-MRI is a valid and efficient tool to detect prostate cancer recurrence in radical prostatectomy as well as in external-beam radiotherapy. The combination of DCE-MRI and DWI is highly efficient after radiation therapy. Three-dimensional (1)H-MRS needs to be improved. Even though it is not accurate enough, T2-weighted imaging remains essential for the morphologic analysis of the area.

  13. [Estimating minimum period of time to perform prostate MRI after prostate biopsy: Clinical and histological bleeding risk factors; from a prospective study].

    Science.gov (United States)

    Sarradin, M; Lepiney, C; Celhay, O; Delpech, P O; Charles, T; Pillot, P; Bernardeau, S; Tasu, J P; Irani, J

    2018-02-01

    A minimum delay of 4 to 6 weeks between biopsy and multiparametric prostatic MRI (mpMRI) is admitted due to post-biopsy hemorrhage that can impact MRI reading without strong scientific evidence. The objective of the study was to evaluate the best period between prostate biopsy and 3Tesla mpMRI and searching for predictive factors of intraprostatic blood. A prostate biopsy followed by a 4-week prostate MRI (MRIp M1) was performed. In case of hemorrhage, MRI was rescheduled at 8 and 12 weeks (M2/M3). We analyzed the persistant bleeding to identify risk factors: anticoagulant/antiaggregant, post-biopsy side effects, histological criteria. In this prospective, single-center study, we included 40 patients followed for suspected prostate cancer between December 2014 and March 2016. At the MRIpM1, blood was found for 97.5 % of the patients. The rates were 90.9 % and 88.9 % respectively at the M2 and M3 mpMRI. Compared to initial blood volume on MRIpM1, a significant decrease in blood volume was observed between M1 and M2 (55 %; P=0.0091). We showed a 75 % decrease between M1 and M3 (P=0.0003). Low urinary tract symptoms (LUTS) suggesting urinary infection at 4 weeks were significantly correlated with blood volume on MRIpM1 (P=0.0063). The blood volume was higher in case of unconformity between biopsy and mpMRI results for detection of significant tumors (11.3 vs. 2.3; P=0.0051). A minimum of 8-week biopsy and mpMRI period would limit post-biopsy hemorrhage, predicted by LUTS suggesting urinary infection. A delay of 12 weeks would be optimal without delaying the management of the patient. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Exploiting Interslice Correlation for MRI Prostate Image Segmentation, from Recursive Neural Networks Aspect

    Directory of Open Access Journals (Sweden)

    Qikui Zhu

    2018-01-01

    Full Text Available Segmentation of the prostate from Magnetic Resonance Imaging (MRI plays an important role in prostate cancer diagnosis. However, the lack of clear boundary and significant variation of prostate shapes and appearances make the automatic segmentation very challenging. In the past several years, approaches based on deep learning technology have made significant progress on prostate segmentation. However, those approaches mainly paid attention to features and contexts within each single slice of a 3D volume. As a result, this kind of approaches faces many difficulties when segmenting the base and apex of the prostate due to the limited slice boundary information. To tackle this problem, in this paper, we propose a deep neural network with bidirectional convolutional recurrent layers for MRI prostate image segmentation. In addition to utilizing the intraslice contexts and features, the proposed model also treats prostate slices as a data sequence and utilizes the interslice contexts to assist segmentation. The experimental results show that the proposed approach achieved significant segmentation improvement compared to other reported methods.

  15. Long-distance longitudinal prostate MRI quality assurance: from startup to 12 months.

    Science.gov (United States)

    Curci, Nicole E; Gartland, Patrick; Shankar, Prasad R; Montgomery, Jeffrey S; Miller, David C; George, Arvin K; Davenport, Matthew S

    2018-02-22

    To evaluate a 12-month long-distance prostate MRI quality assurance (QA) program. The need for IRB approval was waived for this prospective longitudinal QA effort. One academic institution experienced with prostate MRI [~ 1000 examinations/year (Site 2)] partnered with a private institution 240 miles away that was starting a new prostate MRI program (Site 1). Site 1 performed all examinations (N = 249). Four radiologists at Site 1 created finalized reports, then sent images and reports to Site 2 for review on a rolling basis. One radiologist at Site 2 reviewed findings and exam quality and discussed results by phone (~ 2-10 minutes/MRI). In months 1-6 all examinations were reviewed. In months 7-12 only PI-RADS ≤ 2 and 'difficult' cases were reviewed. Repeatability was assessed with intra-class correlation (ICC). 'Clinically significant cancer' was Gleason ≥ 7. Image quality significantly (p < 0.001) improved after the first three months. Inter-rater agreement also improved in months 3-4 [ICC: 0.849 (95% CI 0.744-0.913)] and 5-6 [ICC: 0.768 (95% CI 0.619-0.864)] compared to months 1-2 [ICC: 0.621 (95% CI 0.436-0.756)]. PI-RADS ≤ 2 examinations were reclassified PI-RADS ≥ 3 in 19% (30/162); of these, 23 had post-MRI histology and 57% (13/23) had clinically significant cancer (5.2% of 249). False-negative examinations [N = 18 (PI-RADS ≤ 2 and Gleason ≥ 7)] were more common at Site 1 during months 1-6 [9% (14/160) vs. 4% (4/89)]. Positive predictive values for PI-RADS ≥ 3 were similar. Remote quality assurance of prostate MRI is feasible and useful, enabling new programs to gain durable skills with minimal risk to patients.

  16. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  17. MRI to predict prostate growth and development in children, adolescents and young adults

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Jing; Liu, Huijia; Wen, Didi; Huang, Xufang; Ren, Fang; Huan, Yi [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an City (China); Wang, He [Fourth Military Medical University, Department of Urology, Tangdu Hospital, Xi' an City (China)

    2014-08-06

    The purpose of this study was to investigate the use of MRI in predicting prostate growth and development. A total of 1,500 healthy male volunteers who underwent MRI of the pelvis were included in this prospective study. Subjects were divided into five groups according to age (group A, 2-5 years; group B, 6-10 years; group C, 11-15 years; group D, 16-20 years; group E, 21-25 years). Total prostate volume (TPV) as well as prostate central zone (CZ) and peripheral zone (PZ) were measured and evaluated on MRI. Data of the different groups were compared using variance analysis, Scheffe's method, Kruskal-Wallis H-test, and Pearson's correlation. Statistical significance was inferred at P < 0.05. In groups A and B, the prostates were barely visible. In group C, although TPV was measured, it was hard to distinguish CZ and PZ. In group D, 136 CZ and PZ were clearly visible. In group E, 377 CZ and PZ were clearly visible on T2-weighted imaging (T2WI). The median TPVs of groups A, B, C, D, and E were 0.00 cm{sup 3}, 0.05 cm{sup 3}, 2.83 cm{sup 3}, 8.32 cm{sup 3,} and 11.56 cm{sup 3}, respectively, and the median prostate development scores were 0.08, 0.69, 1.56, 2.38, and 2.74, respectively. Both TPVs and zonal anatomy scores varied significantly among the five groups (P = 0.000). TPV and zonal anatomy score increased with increasing age. MRI provides a reliable quantitative reference for prostate growth and development. (orig.)

  18. Prostate cancer: assessing the effects of androgen-deprivation therapy using quantitative diffusion-weighted and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Hoetker, Andreas M.; Mazaheri, Yousef; Zheng, Junting; Moskowitz, Chaya S.; Berkowitz, Joshua; Pei, Xin; Zelefsky, Michael J.; Lantos, Joshua E.; Hricak, Hedvig; Akin, Oguz

    2015-01-01

    To investigate the effects of androgen-deprivation therapy (ADT) on MRI parameters and evaluate their associations with treatment response measures. The study included 30 men with histopathologically confirmed prostate cancer who underwent MRI before and after initiation of ADT. Thirty-four tumours were volumetrically assessed on DW-MRI (n = 32) and DCE-MRI (n = 18), along with regions of interest in benign prostatic tissue, to calculate apparent diffusion coefficient (ADC) and transfer constant (K trans ) values. Changes in MRI parameters and correlations with clinical parameters (change in prostate-specific antigen [PSA], treatment duration, PSA nadir) were assessed. Prostate volume and PSA values decreased significantly with therapy (p < 0.001). ADC values increased significantly in tumours and decreased in benign prostatic tissue (p < 0.05). Relative changes in ADC and absolute post-therapeutic ADC values differed significantly between tumour and benign tissue (p < 0.001). K trans decreased significantly only in tumours (p < 0.001); relative K trans changes and post-therapeutic values were not significantly different between tumour and benign tissue. The relative change in tumour ADC correlated significantly with PSA decrease. No changes were associated with treatment duration or PSA nadir. Multi-parametric MRI shows significant measurable changes in tumour and benign prostate caused by ADT and may help in monitoring treatment response. (orig.)

  19. Dose-Escalated Robotic SBRT for Stage I-II Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Robert eMeier

    2015-04-01

    Full Text Available Abstract: Stereotactic body radiotherapy (SBRT is the precise external delivery of very high-dose radiotherapy to targets in the body, with treatment completed in one to five fractions. SBRT should be an ideal approach for organ-confined prostate cancer because (I dose escalation should yield improved rates of cancer control; (II the unique radiobiology of prostate cancer favors hypofractionation and (III the conformal nature of SBRT minimizes high-dose radiation delivery to immediately adjacent organs, potentially reducing complications. This approach is also more convenient for patients, and is cheaper than intensity modulated radiotherapy (IMRT. Several external beam platforms are capable of delivering SBRT for early-stage prostate cancer, although most of the mature reported series have employed a robotic non-coplanar platform (i.e., CyberKnife. Several large studies report 5-year biochemical relapse rates which compare favorably to IMRT. Rates of late GU toxicity are similar to those seen with IMRT, and rates of late rectal toxicity may be less than with IMRT and low dose rate (LDR brachytherapy. Patient-reported quality of life (QOL outcomes appear similar to IMRT in the urinary domain. Bowel QOL may be less adversely affected by SBRT than with other radiation modalities. After five years of follow-up, SBRT delivered on a robotic platform is yielding outcomes at least as favorable as IMRT, and may be considered appropriate therapy for stage I-II prostate cancer.

  20. Stormram 3: A Magnetic Resonance Imaging-Compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Stormram 3 is an MRI-compatible robotic system that can perform MR guided breast biopsies of suspicious lesions. The base of the robot measures 160x180x90 mm and it is actuated by five custom pneumatic linear stepper motors, driven by a valve manifold outside the Faraday cage of the MRI scanner. All

  1. Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Tze Yee [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and The University of Texas at Houston Graduate School of Biomedical Sciences, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org; Wang, Jihong; Ibbott, Geoffrey S. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Stafford, R. Jason [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); MacLellan, Christopher [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and The University of Texas at Houston Graduate School of Biomedical Sciences, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Rao, Arvind [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Frank, Steven J. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States)

    2016-07-15

    Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.

  2. Percutaneous cryoablation of prostate cancer guided by rectal ultrasound: a retrospectively analysis of 42 cases

    International Nuclear Information System (INIS)

    Xing Wenge; Guo Zhi; Wang Haitao; Liu Fang; Li Baoguo; Yu Haipeng; Li Yong

    2008-01-01

    Objective: To evaluate the effectiveness and safety of rectal ultrasound-guided agon-hilium percutaneous cryoablation in treatment of patients with median and or late-stage prostate cancer patients. Methods: Retrospectively analysis of 42 cases of with stage C and D prostate cancer patients treated by rectal ultrasound-guided argon-hilium percutaneous cryoablation during the follow-up of 1-12 months. The prostate specific antigen (PSA), biochemical progression-free survival (bPFS), PSA objective response, transrectal ultrasound of the prostate (TRUS), TRUS-guided biopsy of the prostate, the maximum urinary flow rate(MFR), MRI examination at before, and 3,6,12 months after cryoablation were recorded and evaluated. The results were statistically evaluated by using variance analysis. Results: The PSA value at before and 3,6, 12 months after cryoablation were (4.48±1.35), (3.54±1.67), (3.18±1.76), (2.87±1.89) μg/L, respectively; TRUS-measured prostate volumes at before and 3, 6,12 months after cryoablation were (59.7± 8.2), (46.9±8.3), (26.2±3.9), (25.9±3.7) mm 3 , respectively; MFR before and 3, 6,12 months after cryoablation were (10.4±0.8), (14.3±1.2), (18.3±1.3), (18.9±1.3) ml/s, respectively; Compared with before cryoablation, the differences between before and after cryoablation was statistically significant (F= 53.93,747.92,3843.03, respectively, P<0.01). The bPFS rates in 3 months,6 months and 12 months were 95.2% (40/42), 95.2% (40/42), and 90.5% (38/42), respectively. According to the PSA response, the total effective rate (CR 16 cases, PR 15 cases) at 12 months was 73.8%, and SD was 16.7% (7/42), PD was 9.5% (4/42). Complications included temporary incontinence 2.4% (1/42), Penile tingling/numbness 2.4% (1/42), pelvic pain 4.9% (2/41) and Scrotum Edema 2.4% (1/42). There was no case with severe complications such as severe infection or urethrorectal fistula, etc. Conclusions: Rectal ultrasound-guided agon-hilium percutaneous cryoablation showed

  3. To move or not to move: measurements of prostate motion by urethrography using MRI

    International Nuclear Information System (INIS)

    Mah, Dennis; Freedman, Gary; Movsas, Benjamin; Hanlon, Alexandra; Mitra, Raj; Horwitz, Eric; Pinover, Wayne; Iyer, Rajesh; Hanks, G.E.

    2001-01-01

    Purpose: Urethrography is commonly used to aid in definition of the prostate apex during CT simulation for prostate cancer. If the position of the prostate were altered by the urethrogram itself, then systematic error could be introduced into the patient's treatment. Sagittal MRI scans were acquired immediately before and after a localization urethrogram to determine the extent of displacement. Methods and Materials: Thirteen patients underwent sagittal T2-weighted fast spin echo MRI scans. Patients were scanned supine in an alpha cradle cast in the treatment position. The prostate was contoured by 3 different observers to determine the apex location on the central sagittal MRI section and the center of mass relative to an immobile bony landmark. Statistical multivariate analysis was performed to establish if there was a net displacement of the prostate (systematic error), and to determine the margin required to cover the random prostate position within a 95% confidence interval. Results: There was no significant systematic motion of either the prostate nor its apex in either the anterior-posterior or superior-inferior directions. The average motion of the prostate center of mass was 0.04±0.40 cm (1 SD) and 0.01±0.33 cm in the anterior-posterior and superior-inferior direction, respectively. The corresponding figures for location of the apex were 0.05±0.30 cm and 0.01±0.33 cm, respectively. The statistical analysis revealed that a margin of 2 mm is sufficient to cover any random motion of the prostate that could occur as a result of the urethrogram 95% of the time. Conclusion: Urethrography during CT simulation for prostate cancer does not cause significant prostate displacement or systematic error in planning and delivering external-beam radiation

  4. Diagnostic utility of DTI in prostate cancer

    International Nuclear Information System (INIS)

    Guerses, Bengi; Tasdelen, Neslihan; Yencilek, Faruk; Kilickesmez, N. Ozguer; Alp, Turgut; Firat, Zeynep; Albayrak, M. Selami; Ulug, Aziz M.; Guermen, A. Nevzat

    2011-01-01

    Purpose: The aim of this study was to compare the diffusion tensor parameters of prostate cancer, prostatitis and normal prostate tissue. Materials and Methods: A total of 25 patients with the suspicion of prostate cancer were included in the study. MRI was performed with 3 T system (Intera Achieva, Philips Medical Systems, The Netherlands). T2 TSE and DTI with ss-EPI were obtained in each subject. TRUS-guided prostate biopsy was performed after the MRI examination. Images were analyzed by two radiologists using a special software system. ROI's were drawn according to biopsy zones which are apex, midgland, base and central zone on each sides of the gland. FA and ADC values in areas of cancer, chronic prostatitis and normal prostate tissue were compared using Student's t-test. Results: Histopathological analysis revealed carcinoma in 68, chronic prostatitis in 67 and was reported as normal in 65 zones. The mean FA of cancerous tissue was significantly higher (p < 0.01) than the FA of chronic prostatitis and normal gland. The mean ADC of cancerous tissue was found to be significantly lower (p < 0.01), compared with non-cancerous tissue. Conclusion: Decreased ADC and increased FA are compatible with the hypercellular nature of prostate tumors. These differences may increase the accuracy of MRI in the detection of carcinoma and to differentiate between cancer and prostatitis.

  5. Diagnostic utility of DTI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guerses, Bengi, E-mail: bengur0@yahoo.com [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Tasdelen, Neslihan [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Yencilek, Faruk [Yeditepe University Medical Faculty, Department of Urology, Istanbul (Turkey); Kilickesmez, N. Ozguer [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Alp, Turgut [Fatih Sultan Mehmet Training and Research Hospital, Division of Urology, Istanbul (Turkey); Firat, Zeynep [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey); Albayrak, M. Selami [Kartal Training and Research Hospital, Division of Urology, Istanbul (Turkey); Ulug, Aziz M. [Yeditepe University Department of Biomedical Engineering, Istanbul (Turkey); The Feinstein Institute for Medical Research, Manhasset, New York (United States); Guermen, A. Nevzat [Yeditepe University Medical Faculty, Department of Radiology, Istanbul (Turkey)

    2011-08-15

    Purpose: The aim of this study was to compare the diffusion tensor parameters of prostate cancer, prostatitis and normal prostate tissue. Materials and Methods: A total of 25 patients with the suspicion of prostate cancer were included in the study. MRI was performed with 3 T system (Intera Achieva, Philips Medical Systems, The Netherlands). T2 TSE and DTI with ss-EPI were obtained in each subject. TRUS-guided prostate biopsy was performed after the MRI examination. Images were analyzed by two radiologists using a special software system. ROI's were drawn according to biopsy zones which are apex, midgland, base and central zone on each sides of the gland. FA and ADC values in areas of cancer, chronic prostatitis and normal prostate tissue were compared using Student's t-test. Results: Histopathological analysis revealed carcinoma in 68, chronic prostatitis in 67 and was reported as normal in 65 zones. The mean FA of cancerous tissue was significantly higher (p < 0.01) than the FA of chronic prostatitis and normal gland. The mean ADC of cancerous tissue was found to be significantly lower (p < 0.01), compared with non-cancerous tissue. Conclusion: Decreased ADC and increased FA are compatible with the hypercellular nature of prostate tumors. These differences may increase the accuracy of MRI in the detection of carcinoma and to differentiate between cancer and prostatitis.

  6. Prostate cancer: assessing the effects of androgen-deprivation therapy using quantitative diffusion-weighted and dynamic contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hoetker, Andreas M. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Universitaetsmedizin Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Mazaheri, Yousef [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics, New York, NY (United States); Zheng, Junting; Moskowitz, Chaya S. [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Berkowitz, Joshua; Pei, Xin; Zelefsky, Michael J. [Memorial Sloan-Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Lantos, Joshua E.; Hricak, Hedvig; Akin, Oguz [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States)

    2015-09-15

    To investigate the effects of androgen-deprivation therapy (ADT) on MRI parameters and evaluate their associations with treatment response measures. The study included 30 men with histopathologically confirmed prostate cancer who underwent MRI before and after initiation of ADT. Thirty-four tumours were volumetrically assessed on DW-MRI (n = 32) and DCE-MRI (n = 18), along with regions of interest in benign prostatic tissue, to calculate apparent diffusion coefficient (ADC) and transfer constant (K{sup trans}) values. Changes in MRI parameters and correlations with clinical parameters (change in prostate-specific antigen [PSA], treatment duration, PSA nadir) were assessed. Prostate volume and PSA values decreased significantly with therapy (p < 0.001). ADC values increased significantly in tumours and decreased in benign prostatic tissue (p < 0.05). Relative changes in ADC and absolute post-therapeutic ADC values differed significantly between tumour and benign tissue (p < 0.001). K{sup trans} decreased significantly only in tumours (p < 0.001); relative K{sup trans} changes and post-therapeutic values were not significantly different between tumour and benign tissue. The relative change in tumour ADC correlated significantly with PSA decrease. No changes were associated with treatment duration or PSA nadir. Multi-parametric MRI shows significant measurable changes in tumour and benign prostate caused by ADT and may help in monitoring treatment response. (orig.)

  7. MR imaging of the prostate

    International Nuclear Information System (INIS)

    Asbach, P.; Haas, M.; Hamm, B.

    2015-01-01

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [de

  8. SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

    International Nuclear Information System (INIS)

    Padgett, K; Pollack, A; Stoyanova, R; Swallen, A; Nelson, A

    2016-01-01

    Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing

  9. SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

    Energy Technology Data Exchange (ETDEWEB)

    Padgett, K; Pollack, A; Stoyanova, R [University of Miami, Miami, Florida (United States); Swallen, A; Nelson, A [MIM Software Inc., Cleveland, OH (United States)

    2016-06-15

    Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing

  10. Pharmacokinetic MRI of the prostate. Parameters for differentiating low-grade and high-grade prostate cancer

    International Nuclear Information System (INIS)

    Franiel, T.; Taupitz, M.; Asbach, P.; Beyersdorff, D.; Luedemann, L.; Rost, J.

    2009-01-01

    Purpose: to investigate whether pharmacokinetic MRI parameters ''perfusion, blood volume, mean transit time (MTT), interstitial volume, permeability, extraction coefficient, delay, and dispersion'' allow the differentiation of low-grade (Gleason score ≤ 6) and high-grade (Gleason score ≥ 7) prostate cancer. Materials and method: forty-two patients with prostate cancer verified by biopsy (PSA 2.7 to 31.4ng/ml) and scheduled for prostatectomy underwent MRI at 1.5 Tesla using the dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence (temporal resolution, 1.65 s) and a combined endorectal body phased array coil. Parametric maps were computed using a sequential 3-compartment model and the corresponding post-processing algorithms. A total of 41 areas of prostate cancer (15 low-grade, 26 high-grade cancers) in 32 patients were able to be correlated with the prostatectomy specimens and were included in the analysis. Results: low-grade prostate cancers had a higher mean blood volume (1.76% vs. 1.64%, p = 0.039), longer MTT (6.39 s vs. 3.25 s, p -1 vs. 3.86 min -1 , p = 0.011) than high-grade cancers. No statistically significant difference was found for perfusion (p = 0.069), interstitial volume (p = 0.849), extraction coefficient (p = 0.615), delay (p = 0.489), and dispersion (p = 0.306). (orig.)

  11. Value of multiparametric prostate MRI of the peripheral zone

    Energy Technology Data Exchange (ETDEWEB)

    Weidner, Anja M.; Michaely, Henrik J.; Schoenberg, Stefan O.; Dinter, Dietmar J. [University Medical Center Mannheim, Mannheim (Germany). Dept. of Clinical Radiology and Nuclear Medicine; Lemke, Andreas [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Breitinger, Lutz [Privatpraxis fuer Urologie Dr. med. Lutz Breitinger, Mannheim (Germany); Wenz, Frederik [University Medical Center Mannheim, Mannheim (Germany). Dept. of Radiation Oncology; Marx, Alexander [University Hospital Mannheim, Mannheim (Germany). Dept. of Pathology

    2011-07-01

    Rationale and Objectives: MRI of the prostate offers the possibility to localize and stage prostate cancer and may improve detection of disease. Currently, T2-weighted images and spectroscopy are the most commonly used MRI techniques. To assess the value of prostate MRI and its different modalities in the process of diagnosis, the currently available MRI techniques were compared. Materials and Methods: 16 patients were examined on a 1.5 T MR system. All patients underwent the same MR protocol using an endorectal coil: T2-weighted triplanar turbo-spin-echo (TSE), axial echo-planar diffusion-weighted imaging (DWI), 3D chemical-shift imaging MR spectroscopy (MRS) and axial dynamic-contrast-enhanced TurboFLASH (DCE). Parametric maps of the choline+creatine/citrate ratio (CC-CR), apparent diffusion coefficient (ADC) and plasma flow/mean transit time (PF/MTT) were calculated. Additionally, average time for reading and scanning were evaluated. As reference, biopsy results were used. Results: Sensitivity/specificity were 50.0-85.7%/44.4-72.2% for the T2 weighted images, 78.6-100.0%/38.9-55.6% for the ADC maps, 71.4-85.7%/44.4-55.6% for the PF/MTT maps and 64.3-78.6%/50.0-77.8% for the CC-CR. Average scan and reading time were 8:46/1:54 min for T2, 1:28/3:17 min for DWI, 8:41/2:12 min for DCE and 11:36/3:47 for spectroscopy. Conclusion: We found no significant differences in accuracy between the modalities. We observed DWI to be advantageous in examination and reading compared to DCE and MRS, therefore it might be the preferred modality when a shortened protocol is needed. (orig.)

  12. MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment

    International Nuclear Information System (INIS)

    Mu Zhaomei; Ma, C-M; Chen Xiaoming; Cvetkovic, Dusica; Chen Lili; Pollack, Alan

    2012-01-01

    The purpose of this study is to evaluate the efficacy of the enhancement of docetaxel by pulsed focused ultrasound (pFUS) in combination with radiotherapy (RT) for treatment of prostate cancer in vivo. LNCaP cells were grown in the prostates of male nude mice. When the tumors reached a designated volume by MRI, tumor bearing mice were randomly divided into seven groups (n = 5): (1) pFUS alone; (2) RT alone; (3) docetaxel alone; (4) docetaxel + pFUS; (5) docetaxel + RT; (6) docetaxel + pFUS + RT, and (7) control. MR-guided pFUS treatment was performed using a focused ultrasound treatment system (InSightec ExAblate 2000) with a 1.5T GE MR scanner. Animals were treated once with pFUS, docetaxel, RT or their combinations. Docetaxel was given by i.v. injection at 5 mg kg −1 before pFUS. RT was given 2 Gy after pFUS. Animals were euthanized 4 weeks after treatment. Tumor volumes were measured on MRI at 1 and 4 weeks post-treatment. Results showed that triple combination therapies of docetaxel, pFUS and RT provided the most significant tumor growth inhibition among all groups, which may have potential for the treatment of prostate cancer due to an improved therapeutic ratio. (paper)

  13. MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment

    Science.gov (United States)

    Mu, Zhaomei; Ma, C.-M.; Chen, Xiaoming; Cvetkovic, Dusica; Pollack, Alan; Chen, Lili

    2012-01-01

    The purpose of this study is to evaluate the efficacy of the enhancement of docetaxel by pulsed focused ultrasound (pFUS) in combination with radiotherapy (RT) for treatment of prostate cancer in vivo. LNCaP cells were grown in the prostates of male nude mice. When the tumors reached a designated volume by MRI, tumor bearing mice were randomly divided into seven groups (n = 5): (1) pFUS alone; (2) RT alone; (3) docetaxel alone; (4) docetaxel + pFUS (5) docetaxel + RT (6) docetaxel + pFUS + RT, and (7) control. MR-guided pFUS treatment was performed using a focused ultrasound treatment system (InSightec ExAblate 2000) with a 1.5T GE MR scanner. Animals were treated once with pFUS, docetaxel, RT or their combinations. Docetaxel was given by i.v. injection at 5 mg kg-1 before pFUS. RT was given 2 Gy after pFUS. Animals were euthanized 4 weeks after treatment. Tumor volumes were measured on MRI at 1 and 4 weeks post-treatment. Results showed that triple combination therapies of docetaxel, pFUS and RT provided the most significant tumor growth inhibition among all groups, which may have potential for the treatment of prostate cancer due to an improved therapeutic ratio.

  14. Prostate MRI: a national survey of Urologist’s attitudes and perceptions

    Directory of Open Access Journals (Sweden)

    Brandon J. Manley

    2016-06-01

    Full Text Available ABSTRACT Introduction The use of multi-parametric (MP MRI to diagnose prostate cancer has been the subject of intense research, with many studies showing positive results. The purpose of our study is to better understand the accessibility, role, and perceived accuracy of MP-MRI in practice by surveying practicing urologists. Materials and Methods Surveys were sent to 7,400 practicing American Urological Association member physicians with a current email address. The survey asked demographic information and addressed access, accuracy, cost, and role of prostate MRI in clinical practice. Results Our survey elicited 276 responses. Respondents felt that limited access and prohibitive cost of MP-MRI limits its use, 72% and 59% respectively. Academic urologists ordered more MP-MRI studies per year than those in private practice (43.3% vs. 21.1%; p<0.001. Urologists who performed more than 30 prostatectomies a year were more likely to feel that an MP-MRI would change their surgical approach (37.5% vs. 19.6%, p-value=0.002. Only 25% of respondents agreed or strongly agreed that MP-MRI should be used in active surveillance. For patients with negative biopsies and elevated PSA, 39% reported MP-MRI to be very useful. Conclusions Our study found that MP-MRI use is most prominent among practitioners who are oncology fellowship-trained, practice at academic centers, and perform more than 30 prostatectomies per year. Limited access and prohibitive cost of MP-MRI may limit its utility in practice. Additionally, study participants perceive a lack of accuracy of MP-MRI, which is contrary to the recent literature.

  15. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    Science.gov (United States)

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  16. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  17. Imaging of the prostate

    International Nuclear Information System (INIS)

    Turgut, A.

    2012-01-01

    technique, cancerous tissue can be differentiated from benign tissues depending on the hardness gradient and degree of elasticity loss. Nevertheless, the technique is not sufficient yet to preclude the requirement for systematic prostate biopsies. TRUS-guided prostate biopsy has been accepted as the 'gold standard' tool for the detection of prostate cancer. Currently, extended sampling protocols involving 10-12 cores with additional laterally directed cores at the aforementioned levels have been used to increase the diagnostic yield. Magnetic resonance imaging (MRI) is useful for prostate cancer detection primarily in patients with persisting suspicion for undisclosed cancer, despite having negative transrectal US and biopsy findings. MRI can also be used for the localization of cancer within the prostate and in local and distant staging of the disease. Technically, fast spin echo imaging preferably with the combination of endorectal and pelvic phased array coils is recommended for an ideal prostate MRI examination. MRI also aids in the local staging of prostate cancer, as it enables the assessment of the capsular penetration, extracapsular spread and local and distant metastasis. Accordingly, the data derived from endorectal MRI can be used with Partin nomograms to predict extracapsular spread of prostate cancer, in intermediate and high risk patients. MRI is a complementary technique to improve tumor detection by the assessment of tumor metabolism. Dynamic contrast-enhanced MRI, on the other hand, enables direct assessment of the angiogenesis associated with prostate cancer and relative peak enhancement has been accepted as the most accurate perfusion parameter for cancer detection. Diffusion- Weighted Imaging is based on the restriction of diffusion and elevation of apparent diffusion coefficient (ADC) in cancerous tissue compared to the normal prostate tissue. However, the diagnostic accuracy of the technique is diminished by the variability of the ADC values

  18. The longitudinal effect of ejaculation on seminal vesicle fluid volume and whole-prostate ADC as measured on prostate MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Tristan; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Tanner, James; Gill, Andrew B.; Slough, Rhys A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Wason, James [University of Cambridge, MRC Biostatistics Unit, Cambridge (United Kingdom)

    2017-12-15

    To prospectively investigate the longitudinal effect of ejaculatory abstinence on MRI-measured seminal vesicle (SV) volume and whole-prostate ADC over consecutive days. 15 healthy male volunteers (mean 35.9 years, range 27-53) underwent 3-T MRI at baseline and 1, 2 and 3 days post-ejaculation. Prostate and SV volumes were derived by volume segmentation and whole-gland apparent diffusion coefficient (ADC) values calculated. A mixed-effects linear regression compared ADC values and prostate/seminal vesicle volumes in each volunteer between studies in a pairwise manner. All subjects completed the four MRIs. Mean prostate volume was 22.45 cm{sup 3} (range 13.04-31.21 cm{sup 3}), with no change between the four studies (p = 0.89-0.99). 13/15 subjects showed SV volume reduction from baseline to day 1, with group-mean decreasing from 6.45 to 4.80 cm{sup 3} (-25.6%, p < 0.001), and a significant reduction from baseline to day 2 (-18.1%, p = 0.002). There was a significant volume increase from both day 1 (+21.3%, p = 0.006) and day 2 (+10.2%, p = 0.022) to day 3 post-ejaculation. There was a significant reduction in ADC from 1.105 at baseline to 1.056 x 10{sup -3} mm{sup 2}/s at day 1 (mean -4.3%, p = 0.009). The longitudinal effect of ejaculation on SV volume was demonstrated. Significant reductions in SV volume and whole-gland ADC were observed post-ejaculation, supporting a 3-day period of abstinence before prostate MRI. (orig.)

  19. Hemodynamic and metabolic characterization of orthotopic rat prostate carcinomas using dynamic MRI and proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Kauczor, H.U.; Schlemmer, H.P.; Grobholz, R.; Heilmann, M.; Meding, J.; Huber, P.E.; Peschke, P.

    2003-01-01

    The aim of this study was the noninvasive characterization of prostate carcinoma orthotopically implanted in rats using Gd-DTPA-assisted dynamic MRI (dMRI) and proton magnetic resonance spectroscopy ( 1 H-MRS). After surgical exposure of the prostate, Dunning R3327 orthotopic prostate carcinoma was induced by injecting cells of the MAT-LyLu subline. Six rats were examined 5 and 14 days after tumor induction with dMRI and 1 H-MRS at 1.5 T. Six tumor-free rats served as controls. Using an open two-compartment model, the parameters A (amplitude) and k ep (exchange rate constants) were calculated from the signal time curves of the dMRI. The relative signal intensities (Cho/Cr) of the resonances of choline (Cho) and the creatine-phosphocreatine complex (Cr) were computed from the MR spectra. Already after 5 days, the tumors in the prostate could be clearly identified based on the decrease in signal intensity to T2w and increase of A and k ep . High Cho/Cr levels and resonances of two lipid fractions (Lip 1 at 0.8-1.5 ppm and Lip 2 at 2.0-2.2 ppm) were observed by MRS in the highly necrotic tumors. The orthotopic rat prostate carcinoma model resembles human prostate carcinoma in regard to MR morphology, dMRI, and 1 H-MRS. The noninvasive characterization of perfusion and metabolism makes a comparative examination of different treatment modalities possible. (orig.) [de

  20. Robotic Image-Guided Stereotactic Radiotherapy, for Isolated Recurrent Primary, Lymph Node or Metastatic Prostate Cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, Barbara Alicja; Beltramo, Giancarlo; Fariselli, Laura; Fodor, Cristiana; Santoro, Luigi; Vavassori, Andrea; Zerini, Dario; Gherardi, Federica; Ascione, Carmen; Bossi-Zanetti, Isa; Mauro, Roberta; Bregantin, Achille; Bianchi, Livia Corinna; De Cobelli, Ottavio; Orecchia, Roberto

    2012-01-01

    Purpose: To evaluate the outcome of robotic CyberKnife (Accuray, Sunnyvale, CA)–based stereotactic radiotherapy (CBK-SRT) for isolated recurrent primary, lymph node, or metastatic prostate cancer. Methods and Materials: Between May 2007 and December 2009, 34 consecutive patients/38 lesions were treated (15 patients reirradiated for local recurrence [P], 4 patients reirradiated for anastomosis recurrence [A], 16 patients treated for single lymph node recurrence [LN], and 3 patients treated for single metastasis [M]). In all but 4 patients, [ 11 C]choline positron emission tomography/computed tomography was performed. CBK-SRT consisted of reirradiation and first radiotherapy in 27 and 11 lesions, respectively. The median CBK-SRT dose was 30 Gy in 4.5 fractions (P, 30 Gy in 5 fractions; A, 30 Gy in 5 fractions; LN, 33 Gy in 3 fractions; and M, 36 Gy in 3 fractions). In 18 patients (21 lesions) androgen deprivation was added to CBK-SRT (median duration, 16.6 months). Results: The median follow-up was 16.9 months. Acute toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event). Late toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event and 1 Grade 2 event). Biochemical response was observed in 32 of 38 evaluable lesions. Prostate-specific antigen stabilization was seen for 4 lesions, and in 2 cases prostate-specific antigen progression was reported. The 30-month progression-free survival rate was 42.6%. Disease progression was observed for 14 lesions (5, 2, 5, and 2 in Groups P, A, LN, and M respectively). In only 3 cases, in-field progression was seen. At the time of analysis (May 2010), 19 patients are alive with no evidence of disease and 15 are alive with disease. Conclusions: CyberKnife-based stereotactic radiotherapy is a feasible approach for isolated recurrent primary, lymph node, or metastatic prostate cancer, offering excellent in-field tumor

  1. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2014-10-15

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  2. MR-sequences for prostate cancer diagnostics: validation based on the PI-RADS scoring system and targeted MR-guided in-bore biopsy

    International Nuclear Information System (INIS)

    Schimmoeller, Lars; Quentin, Michael; Buchbender, Christian; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Hiester, Andreas; Rabenalt, Robert; Albers, Peter

    2014-01-01

    This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard. In 235 consecutive patients [aged 65.7 ± 7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy. In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern ≥ 4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96. The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers. (orig.)

  3. Logistic regression model for diagnosis of transition zone prostate cancer on multi-parametric MRI.

    Science.gov (United States)

    Dikaios, Nikolaos; Alkalbani, Jokha; Sidhu, Harbir Singh; Fujiwara, Taiki; Abd-Alazeez, Mohamed; Kirkham, Alex; Allen, Clare; Ahmed, Hashim; Emberton, Mark; Freeman, Alex; Halligan, Steve; Taylor, Stuart; Atkinson, David; Punwani, Shonit

    2015-02-01

    We aimed to develop logistic regression (LR) models for classifying prostate cancer within the transition zone on multi-parametric magnetic resonance imaging (mp-MRI). One hundred and fifty-five patients (training cohort, 70 patients; temporal validation cohort, 85 patients) underwent mp-MRI and transperineal-template-prostate-mapping (TPM) biopsy. Positive cores were classified by cancer definitions: (1) any-cancer; (2) definition-1 [≥Gleason 4 + 3 or ≥ 6 mm cancer core length (CCL)] [high risk significant]; and (3) definition-2 (≥Gleason 3 + 4 or ≥ 4 mm CCL) cancer [intermediate-high risk significant]. For each, logistic-regression mp-MRI models were derived from the training cohort and validated internally and with the temporal cohort. Sensitivity/specificity and the area under the receiver operating characteristic (ROC-AUC) curve were calculated. LR model performance was compared to radiologists' performance. Twenty-eight of 70 patients from the training cohort, and 25/85 patients from the temporal validation cohort had significant cancer on TPM. The ROC-AUC of the LR model for classification of cancer was 0.73/0.67 at internal/temporal validation. The radiologist A/B ROC-AUC was 0.65/0.74 (temporal cohort). For patients scored by radiologists as Prostate Imaging Reporting and Data System (Pi-RADS) score 3, sensitivity/specificity of radiologist A 'best guess' and LR model was 0.14/0.54 and 0.71/0.61, respectively; and radiologist B 'best guess' and LR model was 0.40/0.34 and 0.50/0.76, respectively. LR models can improve classification of Pi-RADS score 3 lesions similar to experienced radiologists. • MRI helps find prostate cancer in the anterior of the gland • Logistic regression models based on mp-MRI can classify prostate cancer • Computers can help confirm cancer in areas doctors are uncertain about.

  4. Co-trained convolutional neural networks for automated detection of prostate cancer in multi-parametric MRI.

    Science.gov (United States)

    Yang, Xin; Liu, Chaoyue; Wang, Zhiwei; Yang, Jun; Min, Hung Le; Wang, Liang; Cheng, Kwang-Ting Tim

    2017-12-01

    Multi-parameter magnetic resonance imaging (mp-MRI) is increasingly popular for prostate cancer (PCa) detection and diagnosis. However, interpreting mp-MRI data which typically contains multiple unregistered 3D sequences, e.g. apparent diffusion coefficient (ADC) and T2-weighted (T2w) images, is time-consuming and demands special expertise, limiting its usage for large-scale PCa screening. Therefore, solutions to computer-aided detection of PCa in mp-MRI images are highly desirable. Most recent advances in automated methods for PCa detection employ a handcrafted feature based two-stage classification flow, i.e. voxel-level classification followed by a region-level classification. This work presents an automated PCa detection system which can concurrently identify the presence of PCa in an image and localize lesions based on deep convolutional neural network (CNN) features and a single-stage SVM classifier. Specifically, the developed co-trained CNNs consist of two parallel convolutional networks for ADC and T2w images respectively. Each network is trained using images of a single modality in a weakly-supervised manner by providing a set of prostate images with image-level labels indicating only the presence of PCa without priors of lesions' locations. Discriminative visual patterns of lesions can be learned effectively from clutters of prostate and surrounding tissues. A cancer response map with each pixel indicating the likelihood to be cancerous is explicitly generated at the last convolutional layer of the network for each modality. A new back-propagated error E is defined to enforce both optimized classification results and consistent cancer response maps for different modalities, which help capture highly representative PCa-relevant features during the CNN feature learning process. The CNN features of each modality are concatenated and fed into a SVM classifier. For images which are classified to contain cancers, non-maximum suppression and adaptive

  5. Curie-therapy of prostate cancer assisted by three-dimensional echography and robot

    International Nuclear Information System (INIS)

    Bolla, M.; Giraud, J.Y.; Descotes, J.L.; Long, J.A.; Hungr, N.; Baumann, M.; Troccaz, J.

    2011-01-01

    The author present and report the first assessments of the Prosper system which is based on the use of a robot coupled to methods of automatic tracking of prostate by three-dimensional ultrasonic imagery. This system aims at solving some difficulties met by curie-therapy. System accuracy has been assessed on a deformable anatomic phantom: a needle can be positioned with accuracy smaller that 2 mm, despite deformations and movements of the prostate embedded in the phantom. Short communication

  6. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI

    Science.gov (United States)

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing; Yang, Jenny J.

    2016-06-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI.Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high

  7. Development of MR compatible laparoscope robot using master-slave control method

    International Nuclear Information System (INIS)

    Toyoda, Kazutaka; Jaeheon, Chung; Murata, Masaharu; Odaira, Takeshi; Hashizume, Makoto; Ieiri, Satoshi

    2011-01-01

    Recently, MRI guided robotic surgery has been studied. This surgery uses MRI, a surgical navigation system and a surgical robot system intraoperatively for realization of safer and assured surgeries. We have developed a MR compatible laparoscope robot and 4DOF master manipulator (master) independently. So, in this research we report system integration of the master and the laparoscope robot. The degrees of freedom between the master and the laparoscope robot is the same (4DOF), so that the relation of orientation between master and laparoscope robot is one to one. The network communication method between the master and the laparoscope robot is UDP connection based on TCP/IP protocol for reduction of communication delay. In future work we will do experiments of operability of master-slave laparoscope robot system. (author)

  8. [Magnetic resonance semiotics of prostate cancer according to the PI-RADS classification. The clinical diagnostic algorithm of a study].

    Science.gov (United States)

    Korobkin, A S; Shariya, M A; Chaban, A S; Voskanvan, G A; Vinarov, A Z

    2015-01-01

    to elaborate the magnetic resonance imaging (MRI) signs of prostate cancer (PC) in accordance with the PI-RADS classification during multiparametric MRI (mpMRI). A total of 89 men aged 20 to 82 years were examined. A control group consisted of 8 (9%) healthy volunteers younger than 30 years of age with no urological history to obtain control images and MRI plots and 20 (22.5%) men aged 26-76 years, whose morphological changes were inflammatory and hyperplastic. The second age-matched group included 61 (68.5%) patients diagnosed with prostate cancer at morphological examination. A set of studies included digital rectal examination, serum prostate-specific antigen, and transrectal ultrasound-guided prostate biopsy. All the patients underwent prostate mpMRI applying a 3.0 T Achieva MRI scanner (Philips, the Netherlands). The patients have been found to have mpMRI signs that were typical of PC; its MRI semiotics according to the PI-RADS classification is presented. Each mpMRI procedure has been determined to be of importance and informative value in detecting PC. The comprehensive mpMRI approach to diagnosing PC improves the quality and diagnostic value of prostate MRI.

  9. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    International Nuclear Information System (INIS)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig; Gultekin, David H.; Zheng, Junting; Moskowitz, Chaya; Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J.; Schwartz, Lawrence H.

    2011-01-01

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K trans , k ep , v e , AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values -3 mm 2 /s)], median K trans [1.07 vs. 0.34 (1/min)], and k ep [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  10. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Gultekin, David H. [Memorial Sloan-Kettering Cancer Center, Medical Physics, New York, NY (United States); Zheng, Junting; Moskowitz, Chaya [Memorial Sloan-Kettering Cancer Center, Epidemiology and Biostatistics, New York, NY (United States); Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J. [Memorial Sloan-Kettering Cancer Center, Radiation Oncology, New York, NY (United States); Schwartz, Lawrence H. [Columbia University College of Physicians and Surgeons, Radiology, New York, NY (United States)

    2011-09-15

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K{sup trans}, k{sub ep}, v{sub e}, AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values < 0.05). Biopsy-positive and biopsy-negative prostate sides differed significantly in median ADC [1.44 vs. 1.68 (x 10{sup -3} mm{sup 2}/s)], median K{sup trans} [1.07 vs. 0.34 (1/min)], and k{sub ep} [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  11. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    Science.gov (United States)

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  13. Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer: A comparison between two modalities.

    Science.gov (United States)

    Seppälä, Tiina; Visapää, Harri; Collan, Juhani; Kapanen, Mika; Beule, Annette; Kouri, Mauri; Tenhunen, Mikko; Saarilahti, Kauko

    2015-11-01

    To investigate the conversion of prostate cancer radiotherapy (RT) target definition from CT-based planning into an MRI-only-based planning procedure. Using the CT- and MRI-only-based RT planning protocols, 30 prostate cancer patients were imaged in the RT fixation position. Two physicians delineated the prostate in both CT and T2-weighted MRI images. The CT and MRI images were coregistered based on gold seeds and anatomic borders of the prostate. The uncertainty of the coregistration, as well as differences in target volumes and uncertainty of contour delineation were investigated. Conversion of margins and dose constraints from CT- to MRI-only-based treatment planning was assessed. On average, the uncertainty of image coregistration was 0.4 ± 0.5 mm (one standard deviation, SD), 0.9 ± 0.8 mm and 0.9 ± 0.9 mm in the lateral, anterior-posterior and base-apex direction, respectively. The average ratio of the prostate volume between CT and MRI was 1.20 ± 0.15 (one SD). Compared to the CT-based contours, the MRI-based contours were on average 2-7 mm smaller in the apex, 0-1 mm smaller in the rectal direction and 1-4 mm smaller elsewhere. When converting from a CT-based planning procedure to an MRI-based one, the overall planning target volumes (PTV) are prominently reduced only in the apex. The prostate margins and dose constraints can be retained by this conversion.

  14. The development of remote controlled linear guide and mast vertical guide of repair robot for RV head CRDM nozzle region in NPP

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Seo, Yong Chil; Shin, Ho Cheol; Lee, Sung Uk; Jung, Kyung Min

    2006-11-01

    Reactor vessel which is core instrument in NPP must maintains integrity in the high temperature, high pressure and high radiation environment. Therefore RV must be inspected periodically. If there is defect, the RV must be repaired. A remote controlled linear guide and a vertical guide were developed for a welding repair robot of the RV head CRDM nozzle region. During inspection/maintenance, the RV head is placed RV head storage which is a double circled concrete structure. A linear guide was developed to provide a linear motion to the repair robot, which locates the robot under the RV head. The linear guide also provides a strong support to the robot not to overturn when the robot repairs the RV head. The robot needs lifting about 2m to reach the CRDM nozzle, therefore a vertical guide was developed. For easy traveling, the linear guide is designed 4 parts and the vertical guide is designed 3 parts. A control system was developed to remotely control the guide system which is composed of a connecter box, cables, control box, a computer and a control program. A monitoring system was developed to monitor operation of the guide system

  15. The development of remote controlled linear guide and mast vertical guide of repair robot for RV head CRDM nozzle region in NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Seo, Yong Chil; Shin, Ho Cheol; Lee, Sung Uk; Jung, Kyung Min

    2006-11-15

    Reactor vessel which is core instrument in NPP must maintains integrity in the high temperature, high pressure and high radiation environment. Therefore RV must be inspected periodically. If there is defect, the RV must be repaired. A remote controlled linear guide and a vertical guide were developed for a welding repair robot of the RV head CRDM nozzle region. During inspection/maintenance, the RV head is placed RV head storage which is a double circled concrete structure. A linear guide was developed to provide a linear motion to the repair robot, which locates the robot under the RV head. The linear guide also provides a strong support to the robot not to overturn when the robot repairs the RV head. The robot needs lifting about 2m to reach the CRDM nozzle, therefore a vertical guide was developed. For easy traveling, the linear guide is designed 4 parts and the vertical guide is designed 3 parts. A control system was developed to remotely control the guide system which is composed of a connecter box, cables, control box, a computer and a control program. A monitoring system was developed to monitor operation of the guide system.

  16. Evaluating organ delineation, dose calculation and daily localization in an open-MRI simulation workflow for prostate cancer patients

    International Nuclear Information System (INIS)

    Doemer, Anthony; Chetty, Indrin J; Glide-Hurst, Carri; Nurushev, Teamour; Hearshen, David; Pantelic, Milan; Traughber, Melanie; Kim, Joshua; Levin, Kenneth; Elshaikh, Mohamed A; Walker, Eleanor; Movsas, Benjamin

    2015-01-01

    This study describes initial testing and evaluation of a vertical-field open Magnetic Resonance Imaging (MRI) scanner for the purpose of simulation in radiation therapy for prostate cancer. We have evaluated the clinical workflow of using open MRI as a sole modality for simulation and planning. Relevant results related to MRI alignment (vs. CT) reference dataset with Cone-Beam CT (CBCT) for daily localization are presented. Ten patients participated in an IRB approved study utilizing MRI along with CT simulation with the intent of evaluating the MRI-simulation process. Differences in prostate gland volume, seminal vesicles, and penile bulb were assessed with MRI and compared to CT. To evaluate dose calculation accuracy, bulk-density-assignments were mapped onto respective MRI datasets and treated IMRT plans were re-calculated. For image localization purposes, 400 CBCTs were re-evaluated with MRI as the reference dataset and daily shifts compared against CBCT-to-CT registration. Planning margins based on MRI/CBCT shifts were computed using the van Herk formalism. Significant organ contour differences were noted between MRI and CT. Prostate volumes were on average 39.7% (p = 0.002) larger on CT than MRI. No significant difference was found in seminal vesicle volumes (p = 0.454). Penile bulb volumes were 61.1% higher on CT, without statistical significance (p = 0.074). MRI-based dose calculations with assigned bulk densities produced agreement within 1% with heterogeneity corrected CT calculations. The differences in shift positions for the cohort between CBCT-to-CT registration and CBCT-to-MRI registration are −0.15 ± 0.25 cm (anterior-posterior), 0.05 ± 0.19 cm (superior-inferior), and −0.01 ± 0.14 cm (left-right). This study confirms the potential of using an open-field MRI scanner as primary imaging modality for prostate cancer treatment planning simulation, dose calculations and daily image localization

  17. Feasibility of shutter-speed DCE-MRI for improved prostate cancer detection.

    Science.gov (United States)

    Li, Xin; Priest, Ryan A; Woodward, William J; Tagge, Ian J; Siddiqui, Faisal; Huang, Wei; Rooney, William D; Beer, Tomasz M; Garzotto, Mark G; Springer, Charles S

    2013-01-01

    The feasibility of shutter-speed model dynamic-contrast-enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast-exchange-regime-allowed (FXR-a) shutter-speed model version and the fast-exchange-limit-constrained (FXL-c) standard model are demonstrated. Although the spatial information is more limited, postdynamic-contrast-enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region-of-interest-averaged K(trans) difference [ΔK(trans) ≡ K(trans)(FXR-a) - K(trans)(FXL-c)] or two-dimensional K(trans)(FXR-a) vs. k(ep)(FXR-a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast-exchange-limit-constrained analysis is 63%, with the two-dimensional plot.) K(trans) and k(ep) are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter-speed model (relative to standard model) analysis are larger in malignant foci than in normal-appearing glandular tissue. Pathology analyses verify the shutter-speed model (FXR-a) promise for prostate cancer detection. Parametric mapping may further improve pharmacokinetic biomarker performance. Copyright © 2012 Wiley Periodicals, Inc.

  18. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    NARCIS (Netherlands)

    Nketiah, G.; Elschot, M.; Kim, E.; Teruel, J.R.; Scheenen, T.W.J.; Bathen, T.F.; Selnaes, K.M.

    2017-01-01

    PURPOSE: To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. MATERIALS AND METHODS:

  19. Predicting efficacy of robot-aided rehabilitation in chronic stroke patients using an MRI-compatible robotic device.

    Science.gov (United States)

    Sergi, Fabrizio; Krebs, Hermano Igo; Groissier, Benjamin; Rykman, Avrielle; Guglielmelli, Eugenio; Volpe, Bruce T; Schaechter, Judith D

    2011-01-01

    We are investigating the neural correlates of motor recovery promoted by robot-mediated therapy in chronic stroke. This pilot study asked whether efficacy of robot-aided motor rehabilitation in chronic stroke could be predicted by a change in functional connectivity within the sensorimotor network in response to a bout of motor rehabilitation. To address this question, two stroke patients participated in a functional connectivity MRI study pre and post a 12-week robot-aided motor rehabilitation program. Functional connectivity was evaluated during three consecutive scans before the rehabilitation program: resting-state; point-to-point reaching movements executed by the paretic upper extremity (UE) using a newly developed MRI-compatible sensorized passive manipulandum; resting-state. A single resting-state scan was conducted after the rehabilitation program. Before the program, UE movement reduced functional connectivity between the ipsilesional and contralesional primary motor cortex. Reduced interhemispheric functional connectivity persisted during the second resting-state scan relative to the first and during the resting-state scan after the rehabilitation program. Greater reduction in interhemispheric functional connectivity during the resting-state was associated with greater gains in UE motor function induced by the 12-week robotic therapy program. These findings suggest that greater reduction in interhemispheric functional connectivity in response to a bout of motor rehabilitation may predict greater efficacy of the full rehabilitation program.

  20. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

    Science.gov (United States)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-12-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. • Post-clip MRI is useful for confirming adequate sampling of US-guided biopsy. • Post-clip MRI following US-guided biopsy revealed a 96.6 % technical success rate. • One technical failure case was a benign, 1.1-cm non-mass enhancement. • The technical success rate of US-guided biopsy for non-mass enhancements was 83.3 %.

  1. Rapid ex vivo imaging of PAIII prostate to bone tumor with SWIFT-MRI.

    Science.gov (United States)

    Luhach, Ihor; Idiyatullin, Djaudat; Lynch, Conor C; Corum, Curt; Martinez, Gary V; Garwood, Michael; Gillies, Robert J

    2014-09-01

    The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. SWIFT images with nominal resolution of 78 μm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed. Copyright © 2013 Wiley Periodicals, Inc.

  2. Active MRI tracking for robotic assisted FUS

    Science.gov (United States)

    Xiao, Xu; Huang, Zhihong; Melzer, Andreas

    2017-03-01

    MR guided FUS is a noninvasive method producing thermal necrosis at the position of tumors with high accuracy and temperature control. Because the typical size of the ultrasound focus is smaller than the area of interested treatment tissues, focus repositioning become necessary to achieve multiple sonications to cover the whole targeted area. Using MR compatible mechanical actuators could help the ultrasound beam to reach a wider treatment range than using electrical beam steering technique and more flexibility in position the transducer. An active MR tracking technique was combined into the MRgFUS system to help locating the position of the mechanical actuator and the FUS transducer. For this study, a precise agar reference model was designed and fabricated to test the performance of the active tracking technique when it was used on the MR-compatible robotics InnoMotion™ (IBSMM, Engineering spol. s r.o. / Ltd, Czech Republic). The precision, tracking range and positioning speed of the combined robotic FUS system were evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the FUS treatment to operate in a larger spatial range and with a faster speed, which is one of the main challenges for organ motion tracking.

  3. Differentiation of prostate cancer lesions in the Transition Zone by diffusion-weighted MRI

    Directory of Open Access Journals (Sweden)

    Jie Bao

    Full Text Available Objective: To differentiate prostate cancer lesions in transition zone by diffusion-weighted-MRI (DW-MRI. Methods: Data from a total of 63 patients who underwent preoperative DWI (b of 0–1000 s/mm2 were prospectively collected and processed by a monoexponential (DWI model and compared with a biexponential (IVIM model for quantitation of apparent diffusion coefficients (ADCs, perfusion fraction f, diffusivity D and pseudo-diffusivity D*. Histogram analyses were performed by outlining entire-tumor regions of interest (ROIs. These parameters (separately and combined in a logistic regression model were used to differentiate lesions depending on histopathological analysis of Magnetic Resonance/transrectal Ultrasound (MR/TRUS fusion-guided biopsy. The diagnostic ability of differentiate the PCa from BHP in TZ was analyzed by ROC regression. Histogram analysis of quantitative parameters and Gleason score were assessed with Spearman correlation. Results: Thirty (30 foci cases of PCa in PZ and 33 (36 foci cases of BPH were confirmed by pathology. Mean ADC, median ADC, 10th percentile ADC, 90th percentile ADC, kurtosis and skewness of ADC and mean D values, median D and 90th percentile D differed significantly between PCa and BHP in TZ. The highest classification accuracy was achieved by the mean ADC (0.841 and mean D (0.809. A logistic regression model based on mean ADC and mean D led to an AUC of 0.873, however, the difference is not significant. There were 7 Gleason 6 areas, 9 Gleason 7 areas, 8 Gleason 8 areas, 5 Gleason 9 areas and 2 Gleason 10 areas detected from the 31 prostate cancer areas, the mean Gleason value was(7.5 ± 1.2. The mean ADC and mean D had correlation with Gleason score(r = −0.522 and r = −0.407 respectively, P < 0.05. Conclusion: The diagnosis efficiency of IVIM parameters was not superior to ADC in the diagnosis of PCa in TZ. Moreover, the combination of mean ADC and mean D did not

  4. Prostatome: A combined anatomical and disease based MRI atlas of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela; Madabhushi, Anant, E-mail: anant.madabhushi@case.edu [Case Western Reserve University, Cleveland, Ohio 44106 (United States); Bloch, B. Nicolas; Jaffe, Carl C. [Boston University School of Medicine, Boston, Massachusetts 02118 (United States); Genega, Elizabeth M. [Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215 (United States); Lenkinski, Robert E.; Rofsky, Neil M. [UT Southwestern Medical Center, Dallas, Texas 75235 (United States); Feleppa, Ernest [Riverside Research Institute, New York, New York 10038 (United States)

    2014-07-15

    Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework

  5. Prostatome: A combined anatomical and disease based MRI atlas of the prostate

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Madabhushi, Anant; Bloch, B. Nicolas; Jaffe, Carl C.; Genega, Elizabeth M.; Lenkinski, Robert E.; Rofsky, Neil M.; Feleppa, Ernest

    2014-01-01

    Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework

  6. Value of prostate specific antigen and prostatic volume ratio (PSA/V) as the selection criterion for US-guided prostatic biopsy

    International Nuclear Information System (INIS)

    Veneziano, S.; Paulica, P.; Querze', R.; Viglietta, G.; Trenta, A.

    1991-01-01

    US-guided biopsy was performed in 94 patients with suspected lesions at transerectal US. Histology demonstrated carcinoma in 43 cases, benign hyperplasia in 44, and prostatis in 7. In all cases the prostate specific antigen (PSA) was calculated, by means of US, together with prostatic volume (v). PSA was related to the corresponding gland volume, which resulted in PSA/V ratio. Our study showed PSA/V ration to have higher sensitivity and specificity than absolulute PSA value in the diagnosis of prostatic carcinoma. The authors believe prostate US-guided biopsy to be: a) necessary when the suspected area has PSA/V ratio >0.15, and especially when PSA/V >0.30; b) not indicated when echo-structural alterations are associated with PSA/V <0.15, because they are most frequently due to benign lesions. The combined use of PSA/V ratio and US is therefore suggested to select the patients in whom biopsy is to be performed

  7. MRI tracing non-invasive TiO2-based nanoparticles activated by ultrasound for multi-mechanism therapy of prostatic cancer

    Science.gov (United States)

    Yuan, Pu; Song, Dongkui

    2018-03-01

    To reduce the side effects of chemotherapy and achieve effective and safe therapy for prostate cancer, herein a simple but multi-functional TiO2:Gd@DOX/FA system activated by ultrasound was developed for the MRI-guided multi-mechanism therapy of prostate cancer. TiO2 nanoparticles served as a sonosensitizer as well as a nanocarrier with the pH-responsive release of DOX. The doping of Gd was not only able to endow the TiO2 with magnetic resonance imaging (MRI) ability, but also further improve the sonodynamic ability of the TiO2. The characterization of the as-prepared TiO2:Gd@DOX/FA showed sensitive pH-responsive drug release, high reactive oxygen species (ROS) production, T 1-MRI contrast performance and excellent biocompatibility. The cytotoxicity assay in vitro showed cell death up to 91.68% after 48 h incubation induced by the TiO2:Gd@DOX + ultrasound group. Meanwhile, in the in vivo synergistic therapy studies, the tumor sizes of all the nanomedicine groups were smaller than for the free DOX (V:V 0 = 4.2). More importantly, the body showed nearly no weight loss. This safety was also confirmed by the H&E staining, biodistribution experiment and serum biochemistry results. Altogether, TiO2:Gd@DOX/FA significantly reduced the side effects of DOX, augmented the levels of ROS and achieved effective and safe therapy, indicating its potential for the multi-mechanism therapy of prostate cancer. There is no conflict of interest in this study and no funding has been received for it. We received the approval of the Research Ethics Committee before conducting this study.

  8. Intelligent lead: a novel HRI sensor for guide robots.

    Science.gov (United States)

    Cho, Keum-Bae; Lee, Beom-Hee

    2012-01-01

    This paper addresses the introduction of a new Human Robot Interaction (HRI) sensor for guide robots. Guide robots for geriatric patients or the visually impaired should follow user's control command, keeping a certain desired distance allowing the user to work freely. Therefore, it is necessary to acquire control commands and a user's position on a real-time basis. We suggest a new sensor fusion system to achieve this objective and we will call this sensor the "intelligent lead". The objective of the intelligent lead is to acquire a stable distance from the user to the robot, speed-control volume and turn-control volume, even when the robot platform with the intelligent lead is shaken on uneven ground. In this paper we explain a precise Extended Kalman Filter (EKF) procedure for this. The intelligent lead physically consists of a Kinect sensor, the serial linkage attached with eight rotary encoders, and an IMU (Inertial Measurement Unit) and their measurements are fused by the EKF. A mobile robot was designed to test the performance of the proposed sensor system. After installing the intelligent lead in the mobile robot, several tests are conducted to verify that the mobile robot with the intelligent lead is capable of achieving its goal points while maintaining the appropriate distance between the robot and the user. The results show that we can use the intelligent lead proposed in this paper as a new HRI sensor joined a joystick and a distance measure in the mobile environments such as the robot and the user are moving at the same time.

  9. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  10. Development of a new apparatus for MRI guided stereotactic surgery

    International Nuclear Information System (INIS)

    Iwata, Yukiya; Amano, Keiichi; Kawamura, Hirotsune; Tanikawa, Tatsuya; Kawabatake, Hiroko; Iseki, Hiroshi; Kobayashi, Naotoshi; Ono, Yuko

    1990-01-01

    Since Leksell et al. reported the application of NMR imaging to stereotactic surgery, MRI has been used for determination of the coordinates of target in the brain. The image of the MRI, however, is significantly distorted due to non-uniformity of the magnetic field. The authors have devised a new marker system (the imaginary inner marker system) and have also modified the Iseki CT guided stereotactic frame for utilizing MRI. In this system, the imaginary markers were set up inside the brain. The image of the grid phantom, obtained immediately before the operation, is superimposed on the image of a patient's brain. The nearest image of grid phantom is used for MRI localization as an imaginary inner marker. To prevent distortion and resolution degradation on MRI, the localizing system is composed of acrylic resin and titanium. The head ring can be fixed on both the MRI localizing system and the Iseki CT guided stereotactic frame which allows the transformation of target coordinates from the MRI localizing system to the CT guided frame. MRI guided stereotactic surgery, therefore, can be performed while monitoring with the CT scan. The system was tested using a phantom and taking T 1 -weighted images before clinical application. Coordinates of target points were determined accurately to a 2 mm cube. A 47-year-old, right-handed woman underwent a MRI guided biopsy of the right thalamic mass lesion that was more accurately detected by MRI than CT scan. The histological diagnosis was a malignant lymphoma. No complications have occurred. MRI stereotaxy, at the present time, is expected to be most useful in the biopsy of deep-seated brain lesions which are not easily detected by CT scan. In the near future, It will take the place of other imaging techniques during functional neurosurgery, with sufficient accuracy. (author)

  11. Potential of hybrid 18F-fluorocholine PET/MRI for prostate cancer imaging

    International Nuclear Information System (INIS)

    Perrot, Thomas de; Scheffler, Max; Vallee, Jean-Paul; Rager, Olivier; Ratib, Osman; Lord, Martin; Pusztaszeri, Marc; Iselin, Christophe

    2014-01-01

    To report the first results of hybrid 18 F-fluorocholine PET/MRI imaging for the detection of prostate cancer. This analysis included 26 consecutive patients scheduled for prostate PET/MRI before radical prostatectomy. The examinations were performed on a hybrid whole-body PET/MRI scanner. The MR acquisitions which included T2-weighted, diffusion-weighted and dynamic contrast-enhanced sequences were followed during the same session by whole-body PET scans. Parametric maps were constructed to measure normalized T2-weighted intensity (nT2), apparent diffusion coefficient (ADC), volume transfer constant (K trans ), extravascular extracellular volume fraction (v e ) and standardized uptake values (SUV). With pathology as the gold standard, ROC curves were calculated using logistic regression for each parameter and for the best combination with and without PET to obtain a MR model versus a PETMR model. Of the 26 patients initially selected, 3 were excluded due to absence of an endorectal coil (2 patients) or prosthesis artefacts (1 patient). In the whole prostate, the area under the curve (AUC) for SUV max , ADC, nT2, K trans and v e were 0.762, 0.756, 0.685, 0.611 and 0.529 with a best threshold at 3.044 for SUV max and 1.075 x 10 -3 mm 2 /s for ADC. The anatomical distinction between the transition zone and the peripheral zone showed the potential of the adjunctive use of PET. In the peripheral zone, the AUC of 0.893 for the PETMR model was significantly greater (p = 0.0402) than the AUC of 0.84 for the MR model only. In the whole prostate, no relevant correlation was observed between ADC and SUV max . The SUV max was not affected by the Gleason score. The performance of a hybrid whole-body 18 F-fluorocholine PET/MRI scan in the same session combined with a prostatic MR examination did not interfere with the diagnostic accuracy of the MR sequences. The registration of the PET data and the T2 anatomical MR sequence data allowed precise localization of hypermetabolic

  12. Ex vivo MRI evaluation of prostate cancer: Localization and margin status prediction of prostate cancer in fresh radical prostatectomy specimens.

    Science.gov (United States)

    Heidkamp, Jan; Hoogenboom, Martijn; Kovacs, Iringo E; Veltien, Andor; Maat, Arie; Sedelaar, J P Michiel; Hulsbergen-van de Kaa, Christina A; Fütterer, Jurgen J

    2018-02-01

    To investigate the ability of high field ex vivo magnetic resonance imaging (MRI) to localize prostate cancer (PCa) and to predict the margin status in fresh radical prostatectomy (RP) specimens using histology as the reference standard. This Institutional Review Board (IRB)-approved study had written informed consent. Patients with biopsy-proved PCa and a diagnostic multiparametric 3T MRI examination of the prostate prior to undergoing RP were prospectively included. A custom-made container provided reference between the 7T ex vivo MRI obtained from fresh RP specimens and histological slicing. On ex vivo MRI, PCa was localized and the presence of positive surgical margins was determined in a double-reading session. These findings were compared with histological findings obtained from completely cut, whole-mount embedded, prostate specimens. In 12 RP specimens, histopathology revealed 36 PCa lesions, of which 17 (47%) and 20 (56%) were correlated with the ex vivo MRI in the first and second reading session, respectively. Nine of 12 (75%) index lesions were localized in the first session, in the second 10 of 12 (83%). Seven and 8 lesions of 11 lesions with Gleason score >6 and >0.5 cc were localized in the first and second session, respectively. In the first session none of the four histologically positive surgical margins (sensitivity 0%) and 9 of 13 negative margins (specificity 69%) were detected. In second session the sensitivity and specificity were 25% and 88%, respectively. Ex vivo MRI enabled accurate localization of PCa in fresh RP specimens, and the technique provided information on the margin status with high specificity. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:439-448. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Comparison of primary radiation versus robotic surgery plus adjuvant radiation in high-risk prostate cancer: A single center experience

    Directory of Open Access Journals (Sweden)

    Prabhsimranjot Singh

    2015-01-01

    Full Text Available Objective: The objective of this study was to compare robotic-prostatectomy plus adjuvant radiation therapy (RPRAT versus primary RT for high-risk prostate cancer (HRPCa. Materials and Methods: A retrospective chart review was performed for the HRPCa patients treated in our institution between 2000 and 2010. One hundred and twenty-three patients with high-risk disease were identified. The Chi-square test and Fisher′s exact test were used to compare local control and distant failure rates between the two treatment modalities. For prostate-specific antigen comparisons between groups, Wilcoxon rank-sum test was used. Results: The median follow-up was 49 months (range: 3-138 months. Local control, biochemical recurrence rate, distant metastasis, toxicity, and disease-free survival were similar in the two groups. Conclusions: Primary RT is an excellent treatment option in patients with HRPCa, is equally effective and less expensive treatment compared with RPRAT. A prospective randomized study is required to guide treatment for patients with HRPCa.

  14. Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning

    Science.gov (United States)

    Arabi, Hossein; Koutsouvelis, Nikolaos; Rouzaud, Michel; Miralbell, Raymond; Zaidi, Habib

    2016-09-01

    Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial task, a pseudo-computed tomography (CT) image must be predicted from MRI alone. In this work, we propose a two-step (segmentation and fusion) atlas-based algorithm focusing on bone tissue identification to create a pseudo-CT image from conventional MRI sequences and evaluate its performance against the conventional MRI segmentation technique and a recently proposed multi-atlas approach. The clinical studies consisted of pelvic CT, PET and MRI scans of 12 patients with loco-regionally advanced rectal disease. In the first step, bone segmentation of the target image is optimized through local weighted atlas voting. The obtained bone map is then used to assess the quality of deformed atlases to perform voxel-wise weighted atlas fusion. To evaluate the performance of the method, a leave-one-out cross-validation (LOOCV) scheme was devised to find optimal parameters for the model. Geometric evaluation of the produced pseudo-CT images and quantitative analysis of the accuracy of PET AC were performed. Moreover, a dosimetric evaluation of volumetric modulated arc therapy photon treatment plans calculated using the different pseudo-CT images was carried out and compared to those produced using CT images serving as references. The pseudo-CT images produced using the proposed method exhibit bone identification accuracy of 0.89 based on the Dice similarity metric compared to 0.75 achieved by the other atlas-based method. The superior bone extraction resulted in a mean standard uptake value bias of  -1.5  ±  5.0% (mean  ±  SD) in bony structures compared to  -19.9  ±  11.8% and  -8.1  ±  8.2% achieved by MRI segmentation-based (water

  15. MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer.

    Science.gov (United States)

    Scherr, M K; Seitz, M; Müller-Lisse, U G; Ingrisch, M; Reiser, M F; Müller-Lisse, U L

    2010-12-01

    Various MR methods, including MR-spectroscopy (MRS), dynamic, contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI) have been applied to improve test quality of standard MRI of the prostate. To determine if quantitative, model-based MR-perfusion (MRP) with gadobenate dimeglumine (Gd-BOPTA) discriminates between prostate cancer, benign tissue, and transitional zone (TZ) tissue. 27 patients (age, 65±4 years; PSA 11.0±6.1 ng/ml) with clinical suspicion of prostate cancer underwent standard MRI, 3D MR-spectroscopy (MRS), and MRP with Gd-BOPTA. Based on results of combined MRI/MRS and subsequent guided prostate biopsy alone (17/27), biopsy and radical prostatectomy (9/27), or sufficient negative follow-up (7/27), maps of model-free, deconvolution-based mean transit time (dMTT) were generated for 29 benign regions (bROIs), 14 cancer regions (cROIs), and 18 regions of transitional zone (tzROIs). Applying a 2-compartment exchange model, quantitative perfusion analysis was performed including as parameters: plasma flow (PF), plasma volume (PV), plasma mean transit time (PMTT), extraction flow (EFL), extraction fraction (EFR), interstitial volume (IV) and interstitial mean transit time (IMTT). Two-sided T-tests (significance level pMRP with Gd-BOPTA discriminates between prostate cancer and benign tissue with several parameters. However, distinction of prostate cancer and TZ does not appear to be reliable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  16. Prostate cancer staging with extracapsular extension risk scoring using multiparametric MRI

    DEFF Research Database (Denmark)

    Boesen, Lars; Chabanova, Elizaveta; Løgager, Vibeke

    2015-01-01

    OBJECTIVES: To evaluate the diagnostic performance of preoperative multiparametric MRI with extracapsular extension (ECE) risk-scoring in the assessment of prostate cancer tumour stage (T-stage) and prediction of ECE at final pathology. MATERIALS AND METHODS: Eighty-seven patients with clinically....../87 (36 %) patients. ECE risk-scoring showed an AUC of 0.65-0.86 on ROC-curve for both readers, with sensitivity and specificity of 81 % and 78 % at best cutoff level (reader A), respectively. When tumour characteristics were influenced by personal opinion, the sensitivity and specificity for prediction...... technique for preoperative prostate cancer staging • ECE risk scoring predicts extracapsular tumour extension at final pathology • ECE risk scoring shows an AUC of 0.86 on the ROC-curve • ECE risk scoring shows a moderate inter-reader agreement (K = 0.45) • Multiparametric MRI provides essential knowledge...

  17. Prediction of prostate cancer extracapsular extension with high spatial resolution dynamic contrast-enhanced 3-T MRI

    International Nuclear Information System (INIS)

    Bloch, B.N.; Genega, Elizabeth M.; Costa, Daniel N.; Pedrosa, Ivan; Rofsky, Neil M.; Smith, Martin P.; Kressel, Herbert Y.; Ngo, Long; Sanda, Martin G.; DeWolf, William C.

    2012-01-01

    To assess the value of dynamic contrast-enhanced (DCE) combined with T2-weighted (T2W) endorectal coil (ERC) magnetic resonance imaging (MRI) at 3 T for determining extracapsular extension (ECE) of prostate cancer. In this IRB-approved study, ERC 3-T MRI of the prostate was performed in 108 patients before radical prostatectomy. T2W fast spin-echo and DCE 3D gradient echo images were acquired. The interpretations of readers with varied experience were analysed. MRI-based staging results were compared with radical prostatectomy histology. Descriptive statistics were generated for prediction of ECE and staging accuracies were determined by the area under the receiver-operating characteristic curve. The overall sensitivity, specificity, positive predictive value and negative predictive value for ECE were 75 %, 92 %, 79 % and 91 %, respectively. Diagnostic accuracy for staging was 86 %, 80 % and 91 % for all readers, experienced and less experienced readers, respectively. ERC 3-T MRI of the prostate combining DCE and T2W imaging is an accurate pretherapeutic staging tool for assessment of ECE in clinical practice across varying levels of reader experience. (orig.)

  18. Use of CT or MR dosimetry in high dose rate (HDR) brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Liu, C.; Das, R.; See, A.; Duchesne, G.M.; Van Dyk, S.; Tai, K.H.

    2003-01-01

    Brachytherapy (BT) has, in recent years, become a well-utilised treatment option for prostate cancer. Tumour control probability relies on accurate dosimetry, which in turn relies on the accurate definition of the prostate gland. In external beam radiotherapy and BT, MRI has been shown to be a superior imaging modality when delineating the prostate gland especially at the apex. To date, data on MRI planning in prostate BT has focussed mainly on permanent interstitial implants. No data currently exists comparing MRI vs CT planning in HDR BT and its subsequent impact on prostate dosimetry. To determine the effects of MRI vs CT in HDR BT with respect to prostatic volumes and normal tissue doses, with the evaluations made using dose-volume histograms (DVH). Dosimetry parameters derived using CT and MRI (T2 weighted) scans of 11 patients who had received TRUS guided implants for HDR BT, were compared using the PlatoTM computer planning system. Treatment plans were generated on volumes marked by the same radiation oncologist for each patient. Comparison was made of the treatment plans (dosimetry) between: 1. CT generated plans; 2. CT generated plans assessed using MRI marked volumes and 3. MRI generated plans. We confirm the previously reported results that CT scans can overestimate prostatic volumes compared with MRI. Variations were noted in CT and MRI based plans that may allow improved sparing of the rectum and urethra when using MRI planning. The main disadvantages of using MRI scans are access to facilities as well as identifying a dummy source to adequately define the tips of our catheters. It is feasible to utilise MRI scans for HDR BT planning. The clearer definition of anatomical structures has added advantages when contouring the prostate

  19. Robotically assisted MRgFUS system

    Science.gov (United States)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2010-03-01

    Magnetic resonance imaging guided focus ultrasound surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. The objective of this ongoing work is to establish an MRgFUS therapy unit consisting of a specially designed FUS applicator as an add-on to a commercial robotic assistance system originally designed for percutaneous needle interventions in whole-body MRI systems. The fully MR compatible robotic assistance system InnoMotion™ (Synthes Inc., West Chester, USA; formerly InnoMedic GmbH, Herxheim, Germany) offers six degrees of freedom. The developed add-on FUS treatment applicator features a fixed focus ultrasound transducer (f = 1.7 MHz; f' = 68 mm, NA = 0.44, elliptical shaped -6-dB-focus: 8.1 mm length; O/ = 1.1 mm) embedded in a water-filled flexible bellow. A Mylar® foil is used as acoustic window encompassed by a dedicated MRI loop coil. For FUS application, the therapy unit is directly connected to the head of the robotic system, and the treatment region is targeted from above. A newly in-house developed software tool allowed for complete remote control of the MRgFUS-robot system and online analysis of MRI thermometry data. The system's ability for therapeutic relevant focal spot scanning was tested in a closed-bore clinical 1.5 T MR scanner (Magnetom Symphony, Siemens AG, Erlangen, Germany) in animal experiments with pigs. The FUS therapy procedure was performed entirely under MRI guidance including initial therapy planning, online MR-thermometry, and final contrast enhanced imaging for lesion detection. In vivo trials proved the MRgFUS-robot system as highly MR compatible. MR-guided focal spot scanning experiments were performed and a well-defined pattern of thermal tissue lesions was created. A total in vivo positioning accuracy of the US focus better than 2 mm was estimated which is comparable to existing MRgFUS systems. The newly developed FUS-robotic system offers an accurate, highly flexible focus positioning. With its access

  20. Vision Guided Intelligent Robot Design And Experiments

    Science.gov (United States)

    Slutzky, G. D.; Hall, E. L.

    1988-02-01

    The concept of an intelligent robot is an important topic combining sensors, manipulators, and artificial intelligence to design a useful machine. Vision systems, tactile sensors, proximity switches and other sensors provide the elements necessary for simple game playing as well as industrial applications. These sensors permit adaption to a changing environment. The AI techniques permit advanced forms of decision making, adaptive responses, and learning while the manipulator provides the ability to perform various tasks. Computer languages such as LISP and OPS5, have been utilized to achieve expert systems approaches in solving real world problems. The purpose of this paper is to describe several examples of visually guided intelligent robots including both stationary and mobile robots. Demonstrations will be presented of a system for constructing and solving a popular peg game, a robot lawn mower, and a box stacking robot. The experience gained from these and other systems provide insight into what may be realistically expected from the next generation of intelligent machines.

  1. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Centre, Institute of Radiation Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of)

    2017-12-15

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  2. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    International Nuclear Information System (INIS)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-01-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  3. MRI-guided stereotactic neurosurgical procedures in a diagnostic MRI suite: Background and safe practice recommendations.

    Science.gov (United States)

    Larson, Paul S; Willie, Jon T; Vadivelu, Sudhakar; Azmi-Ghadimi, Hooman; Nichols, Amy; Fauerbach, Loretta Litz; Johnson, Helen Boehm; Graham, Denise

    2017-07-01

    The development of navigation technology facilitating MRI-guided stereotactic neurosurgery has enabled neurosurgeons to perform a variety of procedures ranging from deep brain stimulation to laser ablation entirely within an intraoperative or diagnostic MRI suite while having real-time visualization of brain anatomy. Prior to this technology, some of these procedures required multisite workflow patterns that presented significant risk to the patient during transport. For those facilities with access to this technology, safe practice guidelines exist only for procedures performed within an intraoperative MRI. There are currently no safe practice guidelines or parameters available for facilities looking to integrate this technology into practice in conventional MRI suites. Performing neurosurgical procedures in a diagnostic MRI suite does require precautionary measures. The relative novelty of technology and workflows for direct MRI-guided procedures requires consideration of safe practice recommendations, including those pertaining to infection control and magnet safety issues. This article proposes a framework of safe practice recommendations designed for assessing readiness and optimization of MRI-guided neurosurgical interventions in the diagnostic MRI suite in an effort to mitigate patient risk. The framework is based on existing clinical evidence, recommendations, and guidelines related to infection control and prevention, health care-associated infections, and magnet safety, as well as the clinical and practical experience of neurosurgeons utilizing this technology. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.

  4. Association between penile dynamic contrast-enhanced MRI-derived quantitative parameters and self-reported sexual function in patients with newly diagnosed prostate cancer.

    Science.gov (United States)

    Vargas, Hebert Alberto; Donati, Olivio F; Wibmer, Andreas; Goldman, Debra A; Mulhall, John P; Sala, Evis; Hricak, Hedvig

    2014-10-01

    The high incidence of prostate cancer, coupled with excellent prostate cancer control rates, has resulted in growing interest in nononcological survivorship issues such as sexual function. Multiparametric magnetic resonance imaging (MRI) is increasingly being performed for local staging of prostate cancer, and due to the close anatomical relationship to the prostate, penile enhancement is often depicted in prostate MRI. To evaluate the associations between quantitative perfusion-related parameters derived from dynamic contrast-enhanced (DCE)-MRI of the penis and self-reported sexual function in patients with newly diagnosed prostate cancer. This retrospective study included 50 patients who underwent DCE-MRI for prostate cancer staging before prostatectomy. The following perfusion-related parameters were calculated: volume transfer constant (K(trans)), rate constant (k(ep)), extracellular-extravascular volume fraction (v(e)), contrast enhancement ratio (CER), area under the gadolinium curve after 180 seconds (AUC180), and slope of the time/signal intensity curve of the corpora cavernosa. Associations between perfusion-related parameters and self-reported sexual function were evaluated using the Wilcoxon Rank-Sum test. Patient responses to the sexual function domain of the Prostate Quality of Life survey. Five of the six DCE-MRI parameters (K(trans), v(e), CER, AUC180, and slope) were significantly associated with the overall score from the sexual domain of the survey (P = 0.0020-0.0252). CER, AUC180, and slope were significantly associated with the answers to all six questions (P = 0.0020-0.0483), ve was significantly associated with the answers to five of six questions (P = 0.0036-0.1029), and K(trans) was significantly associated with the answers to three of six questions (P = 0.0252-0.1023). k(ep) was not significantly associated with the overall survey score (P = 0.7665) or the answers to any individual questions (P = 0

  5. Using the visitor experiences for mapping the possibilities of implementing a robotic guide in outdoor sites

    NARCIS (Netherlands)

    Karreman, Daphne Eleonora; van Dijk, Elisabeth M.A.G.; Evers, Vanessa

    2012-01-01

    FROG (Fun Robotic Outdoor Guide) is a project that aims to develop an outdoor robotic guide that enriches the visitor experience in touristic sites. This paper is a first step toward a guide robot and presents a case study on how to analyze the visitors’ experience and examine opportunities for a

  6. Haralick texture analysis of prostate MRI: utility for differentiating non-cancerous prostate from prostate cancer and differentiating prostate cancers with different Gleason scores

    Energy Technology Data Exchange (ETDEWEB)

    Wibmer, Andreas; Hricak, Hedvig; Sala, Evis; Vargas, Hebert Alberto [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York City, NY (United States); Gondo, Tatsuo; Matsumoto, Kazuhiro; Eastham, James [Memorial Sloan Kettering Cancer Center, Department of Urology, New York City, NY (United States); Veeraraghavan, Harini; Fehr, Duc [Memorial Sloan Kettering Cancer Center, Department of Medical Physics, New York City, NY (United States); Zheng, Junting; Goldman, Debra; Moskowitz, Chaya [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York City, NY (United States); Fine, Samson W.; Reuter, Victor E. [Memorial Sloan Kettering Cancer Center, Department of Pathology, New York City, NY (United States)

    2015-10-15

    To investigate Haralick texture analysis of prostate MRI for cancer detection and differentiating Gleason scores (GS). One hundred and forty-seven patients underwent T2- weighted (T2WI) and diffusion-weighted prostate MRI. Cancers ≥0.5 ml and non-cancerous peripheral (PZ) and transition (TZ) zone tissue were identified on T2WI and apparent diffusion coefficient (ADC) maps, using whole-mount pathology as reference. Texture features (Energy, Entropy, Correlation, Homogeneity, Inertia) were extracted and analysed using generalized estimating equations. PZ cancers (n = 143) showed higher Entropy and Inertia and lower Energy, Correlation and Homogeneity compared to non-cancerous tissue on T2WI and ADC maps (p-values: <.0001-0.008). In TZ cancers (n = 43) we observed significant differences for all five texture features on the ADC map (all p-values: <.0001) and for Correlation (p = 0.041) and Inertia (p = 0.001) on T2WI. On ADC maps, GS was associated with higher Entropy (GS 6 vs. 7: p = 0.0225; 6 vs. >7: p = 0.0069) and lower Energy (GS 6 vs. 7: p = 0.0116, 6 vs. >7: p = 0.0039). ADC map Energy (p = 0.0102) and Entropy (p = 0.0019) were significantly different in GS ≤3 + 4 versus ≥4 + 3 cancers; ADC map Entropy remained significant after controlling for the median ADC (p = 0.0291). Several Haralick-based texture features appear useful for prostate cancer detection and GS assessment. (orig.)

  7. Haralick texture analysis of prostate MRI: utility for differentiating non-cancerous prostate from prostate cancer and differentiating prostate cancers with different Gleason scores

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Hricak, Hedvig; Sala, Evis; Vargas, Hebert Alberto; Gondo, Tatsuo; Matsumoto, Kazuhiro; Eastham, James; Veeraraghavan, Harini; Fehr, Duc; Zheng, Junting; Goldman, Debra; Moskowitz, Chaya; Fine, Samson W.; Reuter, Victor E.

    2015-01-01

    To investigate Haralick texture analysis of prostate MRI for cancer detection and differentiating Gleason scores (GS). One hundred and forty-seven patients underwent T2- weighted (T2WI) and diffusion-weighted prostate MRI. Cancers ≥0.5 ml and non-cancerous peripheral (PZ) and transition (TZ) zone tissue were identified on T2WI and apparent diffusion coefficient (ADC) maps, using whole-mount pathology as reference. Texture features (Energy, Entropy, Correlation, Homogeneity, Inertia) were extracted and analysed using generalized estimating equations. PZ cancers (n = 143) showed higher Entropy and Inertia and lower Energy, Correlation and Homogeneity compared to non-cancerous tissue on T2WI and ADC maps (p-values: <.0001-0.008). In TZ cancers (n = 43) we observed significant differences for all five texture features on the ADC map (all p-values: <.0001) and for Correlation (p = 0.041) and Inertia (p = 0.001) on T2WI. On ADC maps, GS was associated with higher Entropy (GS 6 vs. 7: p = 0.0225; 6 vs. >7: p = 0.0069) and lower Energy (GS 6 vs. 7: p = 0.0116, 6 vs. >7: p = 0.0039). ADC map Energy (p = 0.0102) and Entropy (p = 0.0019) were significantly different in GS ≤3 + 4 versus ≥4 + 3 cancers; ADC map Entropy remained significant after controlling for the median ADC (p = 0.0291). Several Haralick-based texture features appear useful for prostate cancer detection and GS assessment. (orig.)

  8. Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Cassidy, R.J., E-mail: richardjcassidy@emory.edu [Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Yang, X.; Liu, T.; Thomas, M. [Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States); Nour, S.G. [Department of Radiology, Emory University, Atlanta, GA (United States); Jani, A.B. [Department of Radiation Oncology, Winship Cancer Institute of Emory University, Atlanta, GA (United States)

    2016-01-01

    Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dose of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.

  9. The Efficacy and Utilisation of Preoperative Magnetic Resonance Imaging in Robot-assisted Radical Prostatectomy: Does it Change the Surgical Dissection Plan? A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Tavukçu

    2015-06-01

    Full Text Available Purpose: We investigated the effect of prostate magnetic resonance imaging (MRI on the dissection plan of the neurovascular bundle and the oncological results of our patients who underwent robotic radical prostatectomy operation. Materials and Methods: We prospectively evaluated 30 consecutive patients, 15 of whom had prostate MRI before the operation, and 15 of whom did not. With the findings of MRI, the dissection plan was changed as intrafascial, interfascial, and extrafascial technique in the MRI group. Two groups were compared in terms of age, prostate-specific antigen (PSA, and Gleason scores (GSs. Surgical margin status was also checked with the final pathology. Results: There was no significant difference between the two groups in terms of age, PSA, biopsy GS, and final pathological GS. MRI changed the initial surgical plan to a nerve-sparing technique in 7 of the 15 patients. Only one patient in the MRI group had a positive surgical margin on bladder neck. MRI was confirmed as the primary tumour localisation in the final pathology in 93.3% of patients. Conclusion: Preoperative prostate MRI influenced the decision to carry out a nerve-sparing technique in 46% of the patients in our study; however, the change to a nerve-sparing technique did not seem to compromise the surgical margin positivity.

  10. Potential of hybrid {sup 18}F-fluorocholine PET/MRI for prostate cancer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Perrot, Thomas de; Scheffler, Max; Vallee, Jean-Paul [Geneva University Hospitals and University of Geneva, Division of Radiology, Geneve 14 (Switzerland); Rager, Olivier; Ratib, Osman [Geneva University Hospitals, Division of Nuclear Medicine, Geneva (Switzerland); Lord, Martin [University of Montreal Hospital Center, Division of Nuclear Medicine, Montreal (Canada); Pusztaszeri, Marc [Geneva University Hospitals, Division of Clinical Pathology, Geneva (Switzerland); Iselin, Christophe [Geneva University Hospitals, Division of Urologic Surgery, Geneva (Switzerland)

    2014-09-15

    To report the first results of hybrid {sup 18}F-fluorocholine PET/MRI imaging for the detection of prostate cancer. This analysis included 26 consecutive patients scheduled for prostate PET/MRI before radical prostatectomy. The examinations were performed on a hybrid whole-body PET/MRI scanner. The MR acquisitions which included T2-weighted, diffusion-weighted and dynamic contrast-enhanced sequences were followed during the same session by whole-body PET scans. Parametric maps were constructed to measure normalized T2-weighted intensity (nT2), apparent diffusion coefficient (ADC), volume transfer constant (K {sup trans}), extravascular extracellular volume fraction (v{sub e}) and standardized uptake values (SUV). With pathology as the gold standard, ROC curves were calculated using logistic regression for each parameter and for the best combination with and without PET to obtain a MR model versus a PETMR model. Of the 26 patients initially selected, 3 were excluded due to absence of an endorectal coil (2 patients) or prosthesis artefacts (1 patient). In the whole prostate, the area under the curve (AUC) for SUV{sub max}, ADC, nT2, K {sup trans} and v{sub e} were 0.762, 0.756, 0.685, 0.611 and 0.529 with a best threshold at 3.044 for SUV{sub max} and 1.075 x 10{sup -3} mm{sup 2}/s for ADC. The anatomical distinction between the transition zone and the peripheral zone showed the potential of the adjunctive use of PET. In the peripheral zone, the AUC of 0.893 for the PETMR model was significantly greater (p = 0.0402) than the AUC of 0.84 for the MR model only. In the whole prostate, no relevant correlation was observed between ADC and SUV{sub max}. The SUV{sub max} was not affected by the Gleason score. The performance of a hybrid whole-body {sup 18}F-fluorocholine PET/MRI scan in the same session combined with a prostatic MR examination did not interfere with the diagnostic accuracy of the MR sequences. The registration of the PET data and the T2 anatomical MR

  11. Zone-specific logistic regression models improve classification of prostate cancer on multi-parametric MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dikaios, Nikolaos; Halligan, Steve; Taylor, Stuart; Atkinson, David; Punwani, Shonit [University College London, Centre for Medical Imaging, London (United Kingdom); University College London Hospital, Departments of Radiology, London (United Kingdom); Alkalbani, Jokha; Sidhu, Harbir Singh [University College London, Centre for Medical Imaging, London (United Kingdom); Abd-Alazeez, Mohamed; Ahmed, Hashim U.; Emberton, Mark [University College London, Research Department of Urology, Division of Surgery and Interventional Science, London (United Kingdom); Kirkham, Alex [University College London Hospital, Departments of Radiology, London (United Kingdom); Freeman, Alex [University College London Hospital, Department of Histopathology, London (United Kingdom)

    2015-09-15

    To assess the interchangeability of zone-specific (peripheral-zone (PZ) and transition-zone (TZ)) multiparametric-MRI (mp-MRI) logistic-regression (LR) models for classification of prostate cancer. Two hundred and thirty-one patients (70 TZ training-cohort; 76 PZ training-cohort; 85 TZ temporal validation-cohort) underwent mp-MRI and transperineal-template-prostate-mapping biopsy. PZ and TZ uni/multi-variate mp-MRI LR-models for classification of significant cancer (any cancer-core-length (CCL) with Gleason > 3 + 3 or any grade with CCL ≥ 4 mm) were derived from the respective cohorts and validated within the same zone by leave-one-out analysis. Inter-zonal performance was tested by applying TZ models to the PZ training-cohort and vice-versa. Classification performance of TZ models for TZ cancer was further assessed in the TZ validation-cohort. ROC area-under-curve (ROC-AUC) analysis was used to compare models. The univariate parameters with the best classification performance were the normalised T2 signal (T2nSI) within the TZ (ROC-AUC = 0.77) and normalized early contrast-enhanced T1 signal (DCE-nSI) within the PZ (ROC-AUC = 0.79). Performance was not significantly improved by bi-variate/tri-variate modelling. PZ models that contained DCE-nSI performed poorly in classification of TZ cancer. The TZ model based solely on maximum-enhancement poorly classified PZ cancer. LR-models dependent on DCE-MRI parameters alone are not interchangeable between prostatic zones; however, models based exclusively on T2 and/or ADC are more robust for inter-zonal application. (orig.)

  12. Malignant paraganglioma of the prostate: case report, depiction by meta-iodobenzylguanidine scintigraphy and review of the literature

    International Nuclear Information System (INIS)

    Shapiro, B.; Gonzalez, E.; Weissman, A.; Ann Arbor, Univ. of Michigan; McHugh, T.; Markel, S.F.

    1997-01-01

    Objective: to describe the 123-I-MIBG scintigraphic, CT, MRI, operative and pathological findings in a case of malignant prostatic paraganglioma and to review the literature on this very rare tumor. Experimental design: clinical imaging and pathological correlation of data in a referred patient. Setting: regional referral center and tertiary referral academic medical center. Patient: 17 year old man presenting with painless hematuria and a large prostatic mass. Interventions and measures: renal ultrasound, transrectal ultrasound, ultrasound guided prostatic biopsy, pelvic CT and MRI, planar and SPECT 123-I-MIBG scintigraphy, and surgical exploration. Results: the patient had a significant hydronephrosis of the left kidney and marked enlargement (120 ml) of the prostate gland by ultrasound. Ultrasound guided biopsies of the prostate and a left pelvic lymph node revealed a neuroendocrine tumor staining positive for chromogranin. CT and MRI revealed a large tumor of the prostate invading the seminal vesicles, bladder and rectum with extensive pelvic lymph node spread. The primary tumor and one of the nodes were shown to be 123-I-MIBG avid confirming the neuroendocrine nature of the tumor. The lesion was unresponsive to chemotherapy and unresectable at surgical exploration. Conclusions: today there have only been 5 reports of prostatic paragangliomas. To our knowledge this is the first to have been studied by MIBG scintigraphy and like most paragangliomas it was MIBG-avid

  13. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  14. Image-guided diagnosis of prostate cancer can increase detection of tumors

    Science.gov (United States)

    In the largest prospective study to date of image-guided technology for identifying suspicious regions of the prostate to biopsy, researchers compared the ability of this technology to detect high-risk prostate cancer with that of the current standard of

  15. Reduction of dose delivered to the rectum and bulb of the penis using MRI delineation for radiotherapy of the prostate

    NARCIS (Netherlands)

    Steenbakkers, Roel J. H. M.; Deurloo, Kirsten E. I.; Nowak, Peter J. C. M.; Lebesque, Joos V.; van Herk, Marcel; Rasch, Coen R. N.

    2003-01-01

    PURPOSE: The prostate volume delineated on MRI is smaller than on CT. The purpose of this study was to determine the influence of MRI- vs. CT-based prostate delineation using multiple observers on the dose to the target and organs at risk during external beam radiotherapy. MATERIALS AND METHODS: CT

  16. Long-term follow-up after modern radical prostate cancer radiotherapy

    DEFF Research Database (Denmark)

    Sander, Lotte

    that clinical target volumes are up to 30% smaller on MRI delineation compared to computer tomography delineation. The overall aim of the thesis was to explore the use of MRI target planning and a Nicle-Titanium prostate stent as fiducial marker for both MR-CT co-registration and image guided radiotherapy....... radiotherapy is a well established treatment modality for prostate cancer. Accuracy and precision are key words with regard to optimal survival and minimal toxicity in modern radiotherapy and are fundamentals in modern radiotherapy. Modern imaging has improved the ability to define radiotherapy target volumes......A significant increase in the prostate cancer incidence has made prostate cancer a major health problem in recent years. Because of the often but unfortunately not always indolent nature of the disease, over-diagnosis and over-treatment are relevant clinical and ethic dilemmas. External beam...

  17. Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy.

    Science.gov (United States)

    Rivest-Hénault, David; Dowson, Nicholas; Greer, Peter B; Fripp, Jurgen; Dowling, Jason A

    2015-07-01

    CT-MR registration is a critical component of many radiation oncology protocols. In prostate external beam radiation therapy, it allows the propagation of MR-derived contours to reference CT images at the planning stage, and it enables dose mapping during dosimetry studies. The use of carefully registered CT-MR atlases allows the estimation of patient specific electron density maps from MRI scans, enabling MRI-alone radiation therapy planning and treatment adaptation. In all cases, the precision and accuracy achieved by registration influences the quality of the entire process. Most current registration algorithms do not robustly generalize and lack inverse-consistency, increasing the risk of human error and acting as a source of bias in studies where information is propagated in a particular direction, e.g. CT to MR or vice versa. In MRI-based treatment planning where both CT and MR scans serve as spatial references, inverse-consistency is critical, if under-acknowledged. A robust, inverse-consistent, rigid/affine registration algorithm that is well suited to CT-MR alignment in prostate radiation therapy is presented. The presented method is based on a robust block-matching optimization process that utilises a half-way space definition to maintain inverse-consistency. Inverse-consistency substantially reduces the influence of the order of input images, simplifying analysis, and increasing robustness. An open source implementation is available online at http://aehrc.github.io/Mirorr/. Experimental results on a challenging 35 CT-MR pelvis dataset demonstrate that the proposed method is more accurate than other popular registration packages and is at least as accurate as the state of the art, while being more robust and having an order of magnitude higher inverse-consistency than competing approaches. The presented results demonstrate that the proposed registration algorithm is readily applicable to prostate radiation therapy planning. Copyright © 2015. Published by

  18. MRI evaluation following partial HIFU therapy for localized prostate cancer: A single-center study.

    Science.gov (United States)

    Hoquetis, L; Malavaud, B; Game, X; Beauval, J B; Portalez, D; Soulie, M; Rischmann, P

    2016-09-01

    To evaluate the value of MRI for surveillance of primary hemi-HIFU therapy for localized PCa in a single-center. Patients with localized prostate cancer were treated with hemi-HIFU from October 2009 to March 2014. All patients performed MRI before focal therapy, the reader was blinded to the treatment. Oncological failure was defined as positive biopsy or biochemical recurrence (Phoenix). Twenty-five patients were treated with hemi-HIFU in one center. The median nadir PSA was 1.45±1.4ng/mL. Prostate volume decreased from 45 cc to 25 cc on MRI findings. At 20 months, none of the patients had histological recurrence. Biochemical-free survival rate was 88%. MRI evaluation had a negative predictive value of 100% on the treated area and 81% on the untreated area. PSAd≥0.1ng/mL(2) was a predictive factor for cancer on untreated area (P=0.042). MRI control at 6 months is a potentially effective evaluation of treated area after hemi-HIFU and may replace randomized biopsies if PSAd<0.1ng/mL(2) during follow-up. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Comparison of 11C-choline-PET/CT and whole body-MRI for staging of prostate cancer

    International Nuclear Information System (INIS)

    Eschmann, S.M.; Rieger, A.; Mueller, M.; Bares, R.; Pfannenberg, A.C.; Aschoff, P.; Claussen, C.D.; Schlemmer, H.P.; Paulsen, F.; Anastasiadis, A.

    2007-01-01

    Aim of this study was to compare the diagnostic accuracy of positron emission tomography and computed tomography with 11 C-Choline (Cho-PET/CT) and whole body magneticresonance imaging (WB-MRI) for diagnostic work-up of prostate cancer. Patients, methods: We evaluated retrospectively 42 patients with untreated prostate cancer (n =17), or increasing levels of prostate-specific antigen (PSA) after curative therapy (n = 25) who had been investigated by both Cho-PET/CT and WB-MRI. MRI, CT, and PET images were separately analyzed by experienced radiologists or nuclear medicine experts, followed by consensus reading. Validation was established by histology, follow-up, or consensus reading. Results: 88/103 detected lesions were considered as malignant: 44 bone metastases, 22 local tumor, 15 lymph node metastases, 3 lung, and 3 brain metastases. One further lesion was located in the adrenal gland, which was a second tumor. Overall sensitivity, specificity and accuracy for Cho-PET/CT were 96.6%, 76.5%, and 93.3%, resp., and for WB-MRI 78.4%, 94.1%, and 81.0%, resp. 3 vertebral metastases had initially been missed by Cho-PET/CT and were found retrospectively. MRI identified 2 bone metastases and 1 lymph node metastasis after being informed about the results of Cho-PET/CT. Conclusions: Cho-PET/CT and WB-MRI both presented high accuracy in the detection of bone and lymph node metastases. The strength of MRI is excellent image quality providing detailed anatomical information whereas the advantage of Cho-PET/CT is high image contrast of pathological foci. (orig.)

  20. Multidisciplinary Functional MR Imaging for Prostate Cancer

    International Nuclear Information System (INIS)

    Kim, Jeong Kon; Jang, Yun Jin; Cho, Gyung Goo

    2009-01-01

    Various functional magnetic resonance (MR) imaging techniques are used for evaluating prostate cancer including diffusion-weighted imaging, dynamic contrast- enhanced MR imaging, and MR spectroscopy. These techniques provide unique information that is helpful to differentiate prostate cancer from non-cancerous tissue and have been proven to improve the diagnostic performance of MRI not only for cancer detection, but also for staging, post-treatment monitoring, and guiding prostate biopsies. However, each functional MR imaging technique also has inherent challenges. Therefore, in order to make accurate diagnoses, it is important to comprehensively understand their advantages and limitations, histologic background related with image findings, and their clinical relevance for evaluating prostate cancer. This article will review the basic principles and clinical significance of functional MR imaging for evaluating prostate cancer

  1. Transperineal template-guided prostate saturation biopsies in men with suspicion of prostate cancer: a pilot study from Pakistan.

    Science.gov (United States)

    Mehmood, K; Mubarak, M; Dhar, M; Rafi, M; Kinsella, J

    2017-12-01

    Traditionally, transrectal ultrasound (TRUS)-guided biopsies are done for the diagnosis of prostate cancer (PCa) in Pakistan. The transperineal template-guided saturation biopsy (TTSB) approach has been recently introduced in Pakistan and we share diagnostic yields and pathological findings of specimens taken for PCa diagnosis in men with elevated serum total prostate specific antigen (PSA) and negative TRUS-guided prostate biopsies. In all, 16 patients investigated at the Department of Urology, Sindh Institute of Urology and Transplantation (SIUT), underwent TTSB. The mean age of patients was 67.8 ± 8.8 (range: 55 - 84) years. The median PSA was 9.5 (IQR: 7.9 - 19.8) ng/ ml. The duration of symptoms before biopsy ranged from 1 month to 144 months. The prostate was enlarged with mean weight of 73.5 ± 55.5 g. Histopathology revealed PCa in 5 of 16 (31.2%) cases. The Gleason score was 6 (3+3), 7 (3+4) and 8 (4+4) in 1 case each (6.3%) and 10 (5+5) in 2 cases (12.5%). At least two cores were positive in all positive cases. None of the patients required antibiotics post-procedure. In conclusion, the TTSB technique is a promising option for patients with elevated PSA level and negative transrectal prostate biopsies for the detection of PCa in our setting.

  2. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  3. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  4. Acute bacterial prostatitis after transrectal ultrasound-guided prostate biopsy: epidemiological, bacteria and treatment patterns from a 4-year prospective study.

    Science.gov (United States)

    Campeggi, Alexandre; Ouzaid, Idir; Xylinas, Evanguelos; Lesprit, Philippe; Hoznek, Andras; Vordos, Dimitri; Abbou, Claude-Clément; Salomon, Laurent; de la Taille, Alexandre

    2014-02-01

    To evaluate the incidence, and clinical and bacterial features of iatrogenic prostatitis within 1 month after transrectal ultrasound-guided biopsy for detection of prostate cancer. From January 2006 to December 2009, 3000 patients underwent a 21-core transrectal ultrasound-guided prostate biopsy at Henri Mondor Hospital (Créteil, France) and were prospectively followed. All patients had a fluoroquinolone antimicrobial prophylaxis for 7 days. The primary study end-point was to evaluate the incidence of iatrogenic acute prostatitis within 1 month after the biopsy. The secondary end-point was to analyze the clinical and the bacterial features of the prostatitis. Overall, 20 patients of the entire study population (0.67%) had an acute bacterial prostatitis within 2.90 ± 1.77 days (range 1-7 days) after the transrectal ultrasound-guided biopsy. The groups of patients with (n = 20) and without (n = 2980) infection were similar in terms of age, prostate-specific antigen level and prostate volume. Escherichia coli was the only isolated bacteria. The subsequent tests for antibiotic susceptibility showed a 95% resistance for fluroquinolone and amoxicillin. Resistance to amoxiclav, trimethoprim-sulfamethoxazole, third generation cephalosporin and amikacin was 70%, 70%, 25% and 5% respectively. No resistance to imipenem was reported. They were all admitted for treatment without the need of intensive care unit referral. Complete recovery was achieved after 21.4 ± 7 days of antibiotic treatment. A fluroquinolone-based regimen still represents an appropriate prophylaxis protocol to minimize the risk of acute prostatitis secondary to prostate biopsy. Patients should be provided the appropriate care soon after the onset of the symptoms. An intravenous third generation cephalosporin or imipenem-based therapy seem to provide satisfying results. © 2013 The Japanese Urological Association.

  5. The Development and Real-World Deployment of FROG, the Fun Robotic Outdoor Guide

    NARCIS (Netherlands)

    Evers, Vanessa; Menezes, Nuno; Merino, Luis; Gavrilla, Dariu; Nabais, Fernando; Pantic, Maja; Alvito, Paulo; Karreman, Daphne Eleonora

    2014-01-01

    This video details the development of an intelligent outdoor Guide robot. The main objective is to deploy an innovative robotic guide which is not only able to show information, but to react to the affective states of the users, and to offer location-based services using augmented reality. The

  6. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  7. Robotics in pediatric surgery: perspectives for imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Adrien J.; Klein, Michael D. [Stuart Frankel Foundation Computer-Assisted Robot-Enhanced Surgery Program, Children' s Research Center of Michigan, Detroit, MI 48201 (United States); Langenburg, Scott E. [Stuart Frankel Foundation Computer-Assisted Robot-Enhanced Surgery Program, Children' s Research Center of Michigan, Detroit, MI 48201 (United States); Department of Pediatric Surgery, Children' s Hospital of Michigan, 3901 Beaubien, Detroit, MI 48201 (United States)

    2004-06-01

    Robotic surgery will give surgeons the ability to perform essentially tremorless microsurgery in tiny spaces with delicate precision and may enable procedures never before possible on children, neonates, and fetuses. Collaboration with radiologists, engineers, and other scientists will permit refinement of image-guided technologies and allow the realization of truly remarkable concepts in minimally invasive surgery. While robotic surgery is now in clinical use in several surgical specialties (heart bypass, prostate removal, and various gastrointestinal procedures), the greatest promise of robotics lies in pediatric surgery. We will briefly review the history and background of robotic technology in surgery, discuss its present benefits and uses and those being explored, and speculate on the future, with attention to the current and potential involvement of imaging modalities and the role of image guidance. (orig.)

  8. Robotics in pediatric surgery: perspectives for imaging

    International Nuclear Information System (INIS)

    Kant, Adrien J.; Klein, Michael D.; Langenburg, Scott E.

    2004-01-01

    Robotic surgery will give surgeons the ability to perform essentially tremorless microsurgery in tiny spaces with delicate precision and may enable procedures never before possible on children, neonates, and fetuses. Collaboration with radiologists, engineers, and other scientists will permit refinement of image-guided technologies and allow the realization of truly remarkable concepts in minimally invasive surgery. While robotic surgery is now in clinical use in several surgical specialties (heart bypass, prostate removal, and various gastrointestinal procedures), the greatest promise of robotics lies in pediatric surgery. We will briefly review the history and background of robotic technology in surgery, discuss its present benefits and uses and those being explored, and speculate on the future, with attention to the current and potential involvement of imaging modalities and the role of image guidance. (orig.)

  9. MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT

    International Nuclear Information System (INIS)

    Chen, Lili; Price, Robert A.; Wang Lu; Li Jinsheng; Qin Lihong; McNeeley, Shawn; Ma, C.-M. Charlie; Freedman, Gary M.; Pollack, Alan

    2004-01-01

    Purpose: Magnetic resonance (MR) and computed tomography (CT) image fusion with CT-based dose calculation is the gold standard for prostate treatment planning. MR and CT fusion with CT-based dose calculation has become a routine procedure for intensity-modulated radiation therapy (IMRT) treatment planning at Fox Chase Cancer Center. The use of MRI alone for treatment planning (or MRI simulation) will remove any errors associated with image fusion. Furthermore, it will reduce treatment cost by avoiding redundant CT scans and save patient, staff, and machine time. The purpose of this study is to investigate the dosimetric accuracy of MRI-based treatment planning for prostate IMRT. Methods and materials: A total of 30 IMRT plans for 15 patients were generated using both MRI and CT data. The MRI distortion was corrected using gradient distortion correction (GDC) software provided by the vendor (Philips Medical System, Cleveland, OH). The same internal contours were used for the paired plans. The external contours were drawn separately between CT-based and MR imaging-based plans to evaluate the effect of any residual distortions on dosimetric accuracy. The same energy, beam angles, dose constrains, and optimization parameters were used for dose calculations for each paired plans using a treatment optimization system. The resulting plans were compared in terms of isodose distributions and dose-volume histograms (DVHs). Hybrid phantom plans were generated for both the CT-based plans and the MR-based plans using the same leaf sequences and associated monitor units (MU). The physical phantom was then irradiated using the same leaf sequences to verify the dosimetry accuracy of the treatment plans. Results: Our results show that dose distributions between CT-based and MRI-based plans were equally acceptable based on our clinical criteria. The absolute dose agreement for the planning target volume was within 2% between CT-based and MR-based plans and 3% between measured dose

  10. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  11. Hypoxia in Prostate Cancer: Correlation of BOLD-MRI With Pimonidazole Immunohistochemistry-Initial Observations

    International Nuclear Information System (INIS)

    Hoskin, Peter J.; Carnell, Dawn M.; Taylor, N. Jane; Smith, Rowena E.; Stirling, J. James; Daley, Frances M.; Saunders, Michele I.; Bentzen, Soren M.; Collins, David J.; D'Arcy, James A.; Padhani, Anwar P.

    2007-01-01

    Purpose: To investigate the ability of blood oxygen level-dependent (BOLD) MRI to depict clinically significant prostate tumor hypoxia. Methods and Materials: Thirty-three patients with prostate carcinoma undergoing radical prostatectomy were studied preoperatively, using gradient echo sequences without and with contrast medium enhancement, to map relative tissue oxygenation according to relaxivity rates and relative blood volume (rBV). Pimonidazole was administered preoperatively, and whole-mount sections of selected tumor-bearing slices were stained for pimonidazole fixation and tumor and nontumor localization. Histologic and imaging parameters were independently mapped onto patient prostate outlines. Using 5-mm grids, 861 nontumor grid locations were compared with 237 tumor grids (with >50% tumor per location) using contingency table analysis with respect to the ability of imaging to predict pimonidazole staining. Results: Twenty patients completed the imaging and histologic protocols. Pimonidazole staining was found in 33% of nontumor and in 70% of tumor grids. The sensitivity of the MR relaxivity parameter R 2 * in depicting tumor hypoxia was high (88%), improving with the addition of low rBV information (95%) without changing specificity (36% and 29%, respectively). High R 2 * increased the positive predictive value for hypoxia by 6% (70% to 76%); conversely, low R 2 * decreased the likelihood of hypoxia being present by 26% (70% to 44%) and by 41% (71% to 30%) when combined with rBV information. Conclusion: R 2 * maps from BOLD-MRI have high sensitivity but low specificity for defining intraprostatic tumor hypoxia. This together with the negative predictive value of 70% when combined with blood volume information makes BOLD-MRI a potential noninvasive technique for mapping prostatic tumor hypoxia

  12. Changes in Prostate Shape and Volume and Their Implications for Radiotherapy After Introduction of Endorectal Balloon as Determined by MRI at 3T

    International Nuclear Information System (INIS)

    Heijmink, Stijn W.T.P.J.; Scheenen, Tom W.J.; Lin, Emile N.J.T. van; Visser, Andries G.; Kiemeney, Lambertus A.L.M.; Witjes, J. Alfred; Barentsz, Jelle O.

    2009-01-01

    Purpose: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. Methods and materials: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T with a body array coil and subsequently with an ERC inflated with 50 mL of fluid. Prospectively, two experienced readers independently evaluated all data sets in random order. The maximal anteroposterior, right-to-left, and craniocaudal prostate diameters, as well as the total prostate and peripheral zone and central gland volumes were measured before and after ERC introduction. The changes in prostate shape and volume were analyzed using Wilcoxon's test for paired samples. Results: The introduction of the ERC significantly changed the prostate shape in all three directions, with mean changes in the anteroposterior, right-to-left, and craniocaudal diameters of 15.7% (5.5 mm), 7.7% (3.5 mm), and 6.3% (2.2 mm), respectively. The mean total prostate, peripheral zone, and central gland volume decreased significantly after ERC introduction by 17.9% (8.3 cm 3 ), 21.6% (4.8 cm 3 ), and 14.2% (3.4 cm 3 ), respectively. Conclusion: ERC introduction as observed by 3T MRI changed the prostate shape and volume significantly. The mean anteroposterior diameter was reduced by nearly one-sixth of its original diameter, and the mean total prostate volume was decreased by approximately 18%. This could cause difficulties and should be considered when using ERC-based MRI for MRI-computed tomography fusion and radiotherapy planning.

  13. Development of the robot system to assist CT-guided brain surgery

    International Nuclear Information System (INIS)

    Koyama, H.; Funakubo, H.; Komeda, T.; Uchida, T.; Takakura, K.

    1999-01-01

    The robot technology was introduced into the stereotactic neurosurgery for application to biopsy, blind surgery, and functional neurosurgery. The authors have developed a newly designed the robot system to assist CT-guided brain surgery, designed to allow a biopsy needle to reach the targget such as a cerebral tumor within a brain automatically on the basis of the X,Y, and Z coordinates obtained by CT scanner. In this paper we describe construction of the robot, the control of the robot by CT image, robot simulation, and investigated a phantom experiment using CT image. (author)

  14. Simultaneous whole-body {sup 18}F-PSMA-1007-PET/MRI with integrated high-resolution multiparametric imaging of the prostatic fossa for comprehensive oncological staging of patients with prostate cancer. A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Martin T.; Bonekamp, David; Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kesch, Claudia; Radtke, Jan P.; Hohenfellner, Markus [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Cardinale, Jens; Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany); Flechsig, Paul; Kratochwil, Clemens; Giesel, Frederik [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Floca, Ralf [German Cancer Research Center, Medical Image Computing Group, Heidelberg (Germany); Eiber, Matthias [Technical University Hospital Munich, Department of Nuclear Medicine, Munich (Germany); Stenzinger, Albrecht [University Hospital Heidelberg, Institute of Pathology, Heidelberg (Germany); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2018-03-15

    The aim of the present study was to explore the clinical feasibility and reproducibility of a comprehensive whole-body {sup 18}F-PSMA-1007-PET/MRI protocol for imaging prostate cancer (PC) patients. Eight patients with high-risk biopsy-proven PC underwent a whole-body PET/MRI (3 h p.i.) including a multi-parametric prostate MRI after {sup 18}F-PSMA-1007-PET/CT (1 h p.i.) which served as reference. Seven patients presented with non-treated PC, whereas one patient presented with biochemical recurrence. SUV{sub mean}-quantification was performed using a 3D-isocontour volume-of-interest. Imaging data was consulted for TNM-staging and compared with histopathology. PC was confirmed in 4/7 patients additionally by histopathology after surgery. PET-artifacts, co-registration of pelvic PET/MRI and MRI-data were assessed (PI-RADS 2.0). The examinations were well accepted by patients and comprised 1 h. SUV{sub mean}-values between PET/CT (1 h p.i.) and PET/MRI (3 h p.i.) were significantly correlated (p < 0.0001, respectively) and similar to literature of {sup 18}F-PSMA-1007-PET/CT 1 h vs 3 h p.i. The dominant intraprostatic lesion could be detected in all seven patients in both PET and MRI. T2c, T3a, T3b and T4 features were detected complimentarily by PET and MRI in five patients. PET/MRI demonstrated moderate photopenic PET-artifacts surrounding liver and kidneys representing high-contrast areas, no PET-artifacts were observed for PET/CT. Simultaneous PET-readout during prostate MRI achieved optimal co-registration results. The presented {sup 18}F-PSMA-1007-PET/MRI protocol combines efficient whole-body assessment with high-resolution co-registered PET/MRI of the prostatic fossa for comprehensive oncological staging of patients with PC. (orig.)

  15. 3Tesla MRI surface coil: Is it sensitive for prostatic imaging??

    African Journals Online (AJOL)

    Mahmoud Agha

    2014-01-30

    Jan 30, 2014 ... MRI, in pre-sampling diagnosis of prostate cancer, in an attempt to use it ... approved by the ethics committee in Al-Mana General Hospital. ... scopy; NPV, negative predictive value; PACS, Picture archiving and ... Some inherited genes had been found to raise the risk for more ..... ciplinary perspective.

  16. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  17. Design and optimization of a brachytherapy robot

    Science.gov (United States)

    Meltsner, Michael A.

    Trans-rectal ultrasound guided (TRUS) low dose rate (LDR) interstitial brachytherapy has become a popular procedure for the treatment of prostate cancer, the most common type of non-skin cancer among men. The current TRUS technique of LDR implantation may result in less than ideal coverage of the tumor with increased risk of negative response such as rectal toxicity and urinary retention. This technique is limited by the skill of the physician performing the implant, the accuracy of needle localization, and the inherent weaknesses of the procedure itself. The treatment may require 100 or more sources and 25 needles, compounding the inaccuracy of the needle localization procedure. A robot designed for prostate brachytherapy may increase the accuracy of needle placement while minimizing the effect of physician technique in the TRUS procedure. Furthermore, a robot may improve associated toxicities by utilizing angled insertions and freeing implantations from constraints applied by the 0.5 cm-spaced template used in the TRUS method. Within our group, Lin et al. have designed a new type of LDR source. The "directional" source is a seed designed to be partially shielded. Thus, a directional, or anisotropic, source does not emit radiation in all directions. The source can be oriented to irradiate cancerous tissues while sparing normal ones. This type of source necessitates a new, highly accurate method for localization in 6 degrees of freedom. A robot is the best way to accomplish this task accurately. The following presentation of work describes the invention and optimization of a new prostate brachytherapy robot that fulfills these goals. Furthermore, some research has been dedicated to the use of the robot to perform needle insertion tasks (brachytherapy, biopsy, RF ablation, etc.) in nearly any other soft tissue in the body. This can be accomplished with the robot combined with automatic, magnetic tracking.

  18. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  19. ''Textural analysis of multiparametric MRI detects transition zone prostate cancer''

    Energy Technology Data Exchange (ETDEWEB)

    Sidhu, Harbir S.; Johnston, Edward W.; Taylor, Stuart A.; Halligan, Steve [Centre for Medical Imaging, University College London, London (United Kingdom); University College London Hospitals NHS Foundation Trust, London (United Kingdom); Benigno, Salvatore; Dikaios, Nikos [Centre for Medical Imaging, University College London, London (United Kingdom); Ganeshan, Balaji [Institute of Nuclear Medicine, University College London, University College Hospital, London (United Kingdom); Allen, Clare; Kirkham, Alex [University College London Hospitals NHS Foundation Trust, London (United Kingdom); Groves, Ashley M. [University College London Hospitals NHS Foundation Trust, London (United Kingdom); Institute of Nuclear Medicine, University College London, University College Hospital, London (United Kingdom); Ahmed, Hashim U.; Emberton, Mark [University College London Hospitals NHS Foundation Trust, London (United Kingdom); University College London, Research Department of Urology, London (United Kingdom); Punwani, Shonit [Centre for Medical Imaging, University College London, London (United Kingdom); University College London Hospitals NHS Foundation Trust, London (United Kingdom); Centre for Medical Imaging, University College London and University College London Hospitals NIHR Biomedical Research Centre, London (United Kingdom)

    2017-06-15

    To evaluate multiparametric-MRI (mpMRI) derived histogram textural-analysis parameters for detection of transition zone (TZ) prostatic tumour. Sixty-seven consecutive men with suspected prostate cancer underwent 1.5T mpMRI prior to template-mapping-biopsy (TPM). Twenty-six men had 'significant' TZ tumour. Two radiologists in consensus matched TPM to the single axial slice best depicting tumour, or largest TZ diameter for those with benign histology, to define single-slice whole TZ-regions-of-interest (ROIs). Textural-parameter differences between single-slice whole TZ-ROI containing significant tumour versus benign/insignificant tumour were analysed using Mann Whitney U test. Diagnostic accuracy was assessed by receiver operating characteristic area under curve (ROC-AUC) analysis cross-validated with leave-one-out (LOO) analysis. ADC kurtosis was significantly lower (p < 0.001) in TZ containing significant tumour with ROC-AUC 0.80 (LOO-AUC 0.78); the difference became non-significant following exclusion of significant tumour from single-slice whole TZ-ROI (p = 0.23). T1-entropy was significantly lower (p = 0.004) in TZ containing significant tumour with ROC-AUC 0.70 (LOO-AUC 0.66) and was unaffected by excluding significant tumour from TZ-ROI (p = 0.004). Combining these parameters yielded ROC-AUC 0.86 (LOO-AUC 0.83). Textural features of the whole prostate TZ can discriminate significant prostatic cancer through reduced kurtosis of the ADC-histogram where significant tumour is included in TZ-ROI and reduced T1 entropy independent of tumour inclusion. (orig.)

  20. Differentiation of prostatitis and prostate cancer by using diffusion-weighted MR imaging and MR-guided biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, Klaas N.A.; Schouten, Martijn G.; Hambrock, Thomas; Litjens, Geert J.S.; Hoeks, Caroline; ten Haken, Bernard; Barentsz, Jelle O.; Fütterer, Johannes Jacobus; Fütterer, Jurgen J.

    2013-01-01

    Purpose To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference. Materials and Methods The need for institutional review

  1. A PET/MRI study towards finding the optimal ["1"8F]Fluciclovine PET protocol for detection and characterisation of primary prostate cancer

    International Nuclear Information System (INIS)

    Elschot, Mattijs; Sandsmark, Elise; Tessem, May-Britt; Selnaes, Kirsten M.; Bathen, Tone F.; Krueger-Stokke, Brage; Stoerkersen, Oeystein; Moestue, Siver A.; Bertilsson, Helena

    2017-01-01

    ["1"8F]Fluciclovine PET imaging shows promise for the assessment of prostate cancer. The purpose of this PET/MRI study is to optimise the PET imaging protocol for detection and characterisation of primary prostate cancer, by quantitative evaluation of the dynamic uptake of ["1"8F]Fluciclovine in cancerous and benign tissue. Patients diagnosed with high-risk primary prostate cancer underwent an integrated ["1"8F]Fluciclovine PET/MRI exam before robot-assisted radical prostatectomy with extended pelvic lymph node dissection. Volumes-of-interest (VOIs) of selected organs (prostate, bladder, blood pool) and sub-glandular prostate structures (tumour, benign prostatic hyperplasia (BPH), inflammation, healthy tissue) were delineated on T2-weighted MR images, using whole-mount histology samples as a reference. Three candidate windows for optimal PET imaging were identified based on the dynamic curves of the mean and maximum standardised uptake value (SUV_m_e_a_n and SUV_m_a_x, respectively). The statistical significance of differences in SUV between VOIs were analysed using Wilcoxon rank sum tests (p<0.05, adjusted for multiple testing). Twenty-eight (28) patients [median (range) age: 66 (55-72) years] were included. An early (W1: 5-10 minutes post-injection) and two late candidate windows (W2: 18-23; W3: 33-38 minutes post-injection) were selected. Late compared with early imaging was better able to distinguish between malignant and benign tissue [W3, SUV_m_e_a_n: tumour vs. BPH 2.5 vs. 2.0 (p<0.001), tumour vs. inflammation 2.5 vs. 1.7 (p<0.001), tumour vs. healthy tissue 2.5 vs. 2.0 (p<0.001); W1, SUV_m_e_a_n: tumour vs. BPH 3.1 vs. 3.1 (p=0.771), tumour vs inflammation 3.1 vs. 2.2 (p=0.021), tumour vs. healthy tissue 3.1 vs. 2.5 (p<0.001)] as well as between high-grade and low/intermediate-grade tumours (W3, SUV_m_e_a_n: 2.6 vs. 2.1 (p=0.040); W1, SUV_m_e_a_n: 3.1 vs. 2.8 (p=0.173)). These differences were relevant to the peripheral zone, but not the central gland

  2. A PET/MRI study towards finding the optimal [{sup 18}F]Fluciclovine PET protocol for detection and characterisation of primary prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Elschot, Mattijs; Sandsmark, Elise; Tessem, May-Britt [NTNU, Norwegian University of Science and Technology, Deparment of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Selnaes, Kirsten M.; Bathen, Tone F. [NTNU, Norwegian University of Science and Technology, Deparment of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Trondheim University Hospital, St. Olavs Hospital, Trondheim (Norway); Krueger-Stokke, Brage [NTNU, Norwegian University of Science and Technology, Deparment of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); Trondheim University Hospital, Department of Radiology, St. Olavs Hospital, Trondheim (Norway); Stoerkersen, Oeystein [Trondheim University Hospital, Department of Pathology, St. Olavs Hospital, Trondheim (Norway); Moestue, Siver A. [NTNU, Norwegian University of Science and Technology, Deparment of Circulation and Medical Imaging, Faculty of Medicine, Trondheim (Norway); NTNU, Norwegian University of Science and Technology, Department of Laboratory Medicine, Children' s and Women' s Health, Faculty of Medicine, Trondheim (Norway); Bertilsson, Helena [Trondheim University Hospital, Department of Urology, St. Olavs Hospital, Trondheim (Norway); NTNU, Norwegian University of Science and Technology, Department of Cancer Research and Molecular Medicine, Faculty of Medicine, Trondheim (Norway)

    2017-04-15

    [{sup 18}F]Fluciclovine PET imaging shows promise for the assessment of prostate cancer. The purpose of this PET/MRI study is to optimise the PET imaging protocol for detection and characterisation of primary prostate cancer, by quantitative evaluation of the dynamic uptake of [{sup 18}F]Fluciclovine in cancerous and benign tissue. Patients diagnosed with high-risk primary prostate cancer underwent an integrated [{sup 18}F]Fluciclovine PET/MRI exam before robot-assisted radical prostatectomy with extended pelvic lymph node dissection. Volumes-of-interest (VOIs) of selected organs (prostate, bladder, blood pool) and sub-glandular prostate structures (tumour, benign prostatic hyperplasia (BPH), inflammation, healthy tissue) were delineated on T2-weighted MR images, using whole-mount histology samples as a reference. Three candidate windows for optimal PET imaging were identified based on the dynamic curves of the mean and maximum standardised uptake value (SUV{sub mean} and SUV{sub max}, respectively). The statistical significance of differences in SUV between VOIs were analysed using Wilcoxon rank sum tests (p<0.05, adjusted for multiple testing). Twenty-eight (28) patients [median (range) age: 66 (55-72) years] were included. An early (W1: 5-10 minutes post-injection) and two late candidate windows (W2: 18-23; W3: 33-38 minutes post-injection) were selected. Late compared with early imaging was better able to distinguish between malignant and benign tissue [W3, SUV{sub mean}: tumour vs. BPH 2.5 vs. 2.0 (p<0.001), tumour vs. inflammation 2.5 vs. 1.7 (p<0.001), tumour vs. healthy tissue 2.5 vs. 2.0 (p<0.001); W1, SUV{sub mean}: tumour vs. BPH 3.1 vs. 3.1 (p=0.771), tumour vs inflammation 3.1 vs. 2.2 (p=0.021), tumour vs. healthy tissue 3.1 vs. 2.5 (p<0.001)] as well as between high-grade and low/intermediate-grade tumours (W3, SUV{sub mean}: 2.6 vs. 2.1 (p=0.040); W1, SUV{sub mean}: 3.1 vs. 2.8 (p=0.173)). These differences were relevant to the peripheral zone, but

  3. Performance of Ultrafast DCE-MRI for Diagnosis of Prostate Cancer.

    Science.gov (United States)

    Chatterjee, Aritrick; He, Dianning; Fan, Xiaobing; Wang, Shiyang; Szasz, Teodora; Yousuf, Ambereen; Pineda, Federico; Antic, Tatjana; Mathew, Melvy; Karczmar, Gregory S; Oto, Aytekin

    2018-03-01

    This study aimed to test high temporal resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for different zones of the prostate and evaluate its performance in the diagnosis of prostate cancer (PCa). Determine whether the addition of ultrafast DCE-MRI improves the performance of multiparametric MRI. Patients (n = 20) with pathologically confirmed PCa underwent preoperative 3T MRI with T2-weighted, diffusion-weighted, and high temporal resolution (~2.2 seconds) DCE-MRI using gadoterate meglumine (Guerbet, Bloomington, IN) without an endorectal coil. DCE-MRI data were analyzed by fitting signal intensity with an empirical mathematical model to obtain parameters: percent signal enhancement, enhancement rate (α), washout rate (β), initial enhancement slope, and enhancement start time along with apparent diffusion coefficient (ADC) and T2 values. Regions of interests were placed on sites of prostatectomy verified malignancy (n = 46) and normal tissue (n = 71) from different zones. Cancer (α = 6.45 ± 4.71 s -1 , β = 0.067 ± 0.042 s -1 , slope = 3.78 ± 1.90 s -1 ) showed significantly (P <.05) faster signal enhancement and washout rates than normal tissue (α = 3.0 ± 2.1 s -1 , β = 0.034 ± 0.050 s -1 , slope = 1.9 ± 1.4 s -1 ), but showed similar percentage signal enhancement and enhancement start time. Receiver operating characteristic analysis showed area under the curve for DCE parameters was comparable to ADC and T2 in the peripheral (DCE 0.67-0.82, ADC 0.80, T2 0.89) and transition zones (DCE 0.61-0.72, ADC 0.69, T2 0.75), but higher in the central zone (DCE 0.79-0.88, ADC 0.45, T2 0.45) and anterior fibromuscular stroma (DCE 0.86-0.89, ADC 0.35, T2 0.12). Importantly, combining DCE with ADC and T2 increased area under the curve by ~30%, further improving the diagnostic accuracy of PCa detection. Quantitative parameters from empirical mathematical model fits to ultrafast

  4. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Science.gov (United States)

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require

  5. Differentiation of Prostatitis and Prostate Cancer by Using Diffusion-weighted MR Imaging and MR-guided Biopsy at 3 T

    NARCIS (Netherlands)

    Nagel, K.N.A.; Schouten, M.G.; Hambrock, T.; Litjens, G.J.S.; Hoeks, C.M.A.; Haken, B.T.; Barentsz, J.O.; Futterer, J.J.

    2013-01-01

    Purpose:To determine if prostatitis and prostate cancer (PCa) can be distinguished by using apparent diffusion coefficients (ADCs) on magnetic resonance (MR) images, with specimens obtained at MR-guided biopsy as the standard of reference.Materials and Methods:The need for institutional review board

  6. Haralick textural features on T2 -weighted MRI are associated with biochemical recurrence following radiotherapy for peripheral zone prostate cancer.

    Science.gov (United States)

    Gnep, Khémara; Fargeas, Auréline; Gutiérrez-Carvajal, Ricardo E; Commandeur, Frédéric; Mathieu, Romain; Ospina, Juan D; Rolland, Yan; Rohou, Tanguy; Vincendeau, Sébastien; Hatt, Mathieu; Acosta, Oscar; de Crevoisier, Renaud

    2017-01-01

    To explore the association between magnetic resonance imaging (MRI), including Haralick textural features, and biochemical recurrence following prostate cancer radiotherapy. In all, 74 patients with peripheral zone localized prostate adenocarcinoma underwent pretreatment 3.0T MRI before external beam radiotherapy. Median follow-up of 47 months revealed 11 patients with biochemical recurrence. Prostate tumors were segmented on T 2 -weighted sequences (T 2 -w) and contours were propagated onto the coregistered apparent diffusion coefficient (ADC) images. We extracted 140 image features from normalized T 2 -w and ADC images corresponding to first-order (n = 6), gradient-based (n = 4), and second-order Haralick textural features (n = 130). Four geometrical features (tumor diameter, perimeter, area, and volume) were also computed. Correlations between Gleason score and MRI features were assessed. Cox regression analysis and random survival forests (RSF) were performed to assess the association between MRI features and biochemical recurrence. Three T 2 -w and one ADC Haralick textural features were significantly correlated with Gleason score (P recurrence (P recurrence following prostate cancer radiotherapy. 3 J. Magn. Reson. Imaging 2017;45:103-117. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology.

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody; Song, Daniel Y

    2015-08-01

    Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: (125)I fixed spacing, (125)I variable spacing, (103)Pd fixed spacing, and (103)Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with (103)Pd, and 0.007 and 0.029 with (125)I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with (103)Pd, and 0.012 and 0.037 with (125)I plans. The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy.

  8. Diffusion-weighted MRI of the prostate at 3.0 T: comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI-The impact of SNR on ADC measurement.

    Science.gov (United States)

    Mazaheri, Yousef; Vargas, H Alberto; Nyman, Gregory; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig

    2013-10-01

    To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC+PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T. The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC+PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm(2)) were acquired using both coil arrangements. On b=0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed. Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (PERC-MRI (PERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Development and validation of a logistic regression model to distinguish transition zone cancers from benign prostatic hyperplasia on multi-parametric prostate MRI

    Energy Technology Data Exchange (ETDEWEB)

    Iyama, Yuji [Kumamoto Chuo Hospital, Department of Diagnostic Radiology, Kumamoto, Kumamoto (Japan); Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto, Kumamoto (Japan); Nakaura, Takeshi; Nagayama, Yasunori; Utsunomiya, Daisuke; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto, Kumamoto (Japan); Katahira, Kazuhiro; Oda, Seitaro [Kumamoto Chuo Hospital, Department of Diagnostic Radiology, Kumamoto, Kumamoto (Japan); Iyama, Ayumi [National Hospital Organization Kumamoto Medical Center, Department of Diagnostic Radiology, Kumamoto, Kumamoto (Japan)

    2017-09-15

    To develop a prediction model to distinguish between transition zone (TZ) cancers and benign prostatic hyperplasia (BPH) on multi-parametric prostate magnetic resonance imaging (mp-MRI). This retrospective study enrolled 60 patients with either BPH or TZ cancer, who had undergone 3 T-MRI. We generated ten parameters for T2-weighted images (T2WI), diffusion-weighted images (DWI) and dynamic MRI. Using a t-test and multivariate logistic regression (LR) analysis to evaluate the parameters' accuracy, we developed LR models. We calculated the area under the receiver operating characteristic curve (ROC) of LR models by a leave-one-out cross-validation procedure, and the LR model's performance was compared with radiologists' performance with their opinion and with the Prostate Imaging Reporting and Data System (Pi-RADS v2) score. Multivariate LR analysis showed that only standardized T2WI signal and mean apparent diffusion coefficient (ADC) maintained their independent values (P < 0.001). The validation analysis showed that the AUC of the final LR model was comparable to that of board-certified radiologists, and superior to that of Pi-RADS scores. A standardized T2WI and mean ADC were independent factors for distinguishing between BPH and TZ cancer. The performance of the LR model was comparable to that of experienced radiologists. (orig.)

  10. Stormram 4: An MR Safe Robotic System for Breast Biopsy.

    Science.gov (United States)

    Groenhuis, Vincent; Siepel, Françoise J; Veltman, Jeroen; van Zandwijk, Jordy K; Stramigioli, Stefano

    2018-05-21

    Suspicious lesions in the breast that are only visible on magnetic resonance imaging (MRI) need to be biopsied under MR guidance with high accuracy and efficiency for accurate diagnosis. The aim of this study is to present a novel robotic system, the Stormram 4, and to perform preclinical tests in an MRI environment. Excluding racks and needle, its dimensions are 72 × 51 × 40 mm. The Stormram 4 is driven by two linear and two curved pneumatic stepper motors. The linear motor is capable of exerting 63 N of force at a pressure of 0.65 MPa. In an MRI environment the maximum observed stepping frequency is 30 Hz (unloaded), or 8 Hz when full force is needed. The Stormram 4's mean positioning error is 0.73 ± 0.47 mm in free air, and 1.29 ± 0.59 mm when targeting breast phantoms in MRI. Excluding the off-the-shelf needle, the robot is inherently MR safe. The robot is able to accurately target lesions under MRI guidance, reducing tissue damage and risk of false negatives. These results are promising for clinical experiments, improving the quality of healthcare in the field of MRI-guided breast biopsies.

  11. Feasibility study of a hand guided robotic drill for cochleostomy.

    Science.gov (United States)

    Brett, Peter; Du, Xinli; Zoka-Assadi, Masoud; Coulson, Chris; Reid, Andrew; Proops, David

    2014-01-01

    The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  12. Differentiation of prostate cancer lesions with high and with low Gleason score by diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Sebastiano; Broennimann, Michael; Vermathen, Peter; Thoeny, Harriet C. [Inselspital University Hospital, Institute of Diagnostic, Pediatric, and Interventional Radiology, Bern (Switzerland); Boxler, Silvan [Inselspital, Inselspital University Hospital, Department of Urology, Bern (Switzerland)

    2017-04-15

    To differentiate prostate cancer lesions with high and with low Gleason score by diffusion-weighted-MRI (DW-MRI). This prospective study was approved by the responsible ethics committee. DW-MRI of 84 consenting prostate and/or bladder cancer patients scheduled for radical prostatectomy were acquired and used to compute apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM: the pure diffusion coefficient D{sub t}, the pseudo-diffusion fraction F{sub p} and the pseudo-diffusion coefficient D{sub p}), and high b value (as acquired and Hessian filtered) parameters within the index lesion. These parameters (separately and combined in a logistic regression model) were used to differentiate lesions depending on whether whole-prostate histopathological analysis after prostatectomy determined a high (≥7) or low (6) Gleason score. Mean ADC and D{sub t} differed significantly (p of independent two-sample t test < 0.01) between high- and low-grade lesions. The highest classification accuracy was achieved by the mean ADC (AUC 0.74) and D{sub t} (AUC 0.70). A logistic regression model based on mean ADC, mean F{sub p} and mean high b value image led to an AUC of 0.74 following leave-one-out cross-validation. Classification by IVIM parameters was not superior to classification by ADC. DW-MRI parameters correlated with Gleason score but did not provide sufficient information to classify individual patients. (orig.)

  13. Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI

    International Nuclear Information System (INIS)

    Padhani, Anwar R.; Khoo, Vincent S.; Suckling, John; Husband, Janet E.; Leach, Martin O.; Dearnaley, David P.

    1999-01-01

    Purpose: To evaluate the dynamic interrelationship between rectal distension and rectal movements, and to determine the effect of rectal movement on the position of the prostatic gland using cine magnetic resonance imaging (MRI). Methods and Materials: Fifty-five patients with biopsy-proven or suspected prostate cancer were examined in the axial plane using repeated spoiled gradient-echo sequences every 10 seconds for 7 minutes. Twenty-four patients received bowel relaxants before imaging. Images were analyzed for the degree of rectal distension, for the incidence, magnitude, and number of rectal and prostate movements. Results: Rectal movements were seen in 28 (51%) patients overall, in 10 (42%) of those receiving bowel relaxants and in 18 (58%) not receiving bowel relaxants. The incidence of rectal movements correlated with the degree of rectal distension (p = 0.0005), but the magnitude of rectal movements did not correlate with the degree of rectal distension. Eighty-six rectal movements resulting in 33 anterior-posterior (AP) prostate movements were seen. The magnitude of rectal movements correlated well with degree of prostate movements (p < 0.001). Prostate movements in the AP direction were seen in 16 (29%) patients, and in 9 (16%) patients the movement was greater than 5 mm. The median prostate AP displacement was anterior by 4.2 (-5 to +14 mm). Conclusions: Cine MRI is able to demonstrate near real time rectal and associated prostate movements. Rectal movements are related to rectal distension and result in significant displacements of the prostate gland over a time period similar to that used for daily fractionated radiotherapy treatments. Delivery of radiotherapy needs to take into account these organ movements

  14. High concordance of findings obtained from transgluteal magnetic resonance imaging - and transrectal ultrasonography-guided biopsy as compared with prostatectomy specimens.

    Science.gov (United States)

    Steurer, Stefan; Rico, Sebastian Dwertmann; Simon, Ronald; Minner, Sarah; Tsourlakis, Maria Christina; Krech, Till; Koop, Christina; Graefen, Markus; Heinzer, Hans; Adam, Meike; Huland, Hartwig; Schlomm, Thorsten; Sauter, Guido; Lumiani, Agron

    2017-09-01

    To determine the utility of our transgluteal magnetic resonance imaging (MRI)-guided prostate biopsy approach. A total of 960 biopsy series, taken within the period of 1 year, were evaluated, including 301 MRI-guided and 659 transrectal ultrasonography (TRUS)-guided biopsies. The positivity rate and proportion of high grade cancers were significantly higher in MRI-guided than in TRUS-guided biopsies. Of 301 MRI-guided biopsies, 65.4% contained cancer while 57.2% of 659 TRUS biopsies contained cancer (P = 0.016). Gleason grade 3 + 3 = 6 disease was observed in 16.8% of 197 MRI-guided and in 36.1% of 377 TRUS-guided biopsies (P guided biopsies. In all cancers, the mean cancer surface area was 64.8 ± 51.6 mm 2 in MRI-guided biopsies as compared with 23.0 ± 31.4 mm 2 in non-MRI-guided biopsies (P guided biopsy was highest in Gleason grade 3 + 3 = 6 cancers (20.9 ± 27.9 vs 5.1 ± 10.2 mm 2 ; P guided and in 170 patients with non-MRI-guided biopsies. This comparison showed a very high but almost identical concordance of TRUS- and MRI-guided biopsies with the prostatectomy specimen findings. With both approaches, undetected high-risk cancers were present in ~10% of patients with low-risk biopsy results. A significant difference was observed, however, in the proportion of patients who had clinically insignificant cancers and who underwent surgery. The proportion of patients with Gleason grade 3 + 3 = 6 carcinoma in their prostatectomy specimen was 11.2% in the post-TRUS biopsy cohort, but only 2.5% in the post-MRI biopsy cohort (P = 0.021). MRI-guided transgluteal prostate biopsy has a high detection rate for high-risk carcinomas, while the risk of detecting clinically insignificant carcinomas appears to be reduced. This may by itself lead to a reduction of unnecessary prostatectomies. Overtreatment may be further avoided by better applicability of molecular testing to MRI-guided biopsies because of the excessive amount of tissue available for analysis, especially in

  15. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hye Young [Department of Radiology, Gyeongsang National University Hospital, Jinju 660-702 (Korea, Republic of); Kim, Sun Mi; Jang, Mijung; Yun, Bo La [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Kim, Sung-Won; Kang, Eunyoung [Department of Surgery, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Park, So Yeon [Department of Pathology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Ko, Eun Sook [Department of Radiology, Samsung Medical Center, Seoul 135-710 (Korea, Republic of)

    2013-07-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions.

  16. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Sung-Won; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Ko, Eun Sook

    2013-01-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions

  17. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Valli, Lorella [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Aluwini, Shafak [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Lanconelli, Nico [Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Heijmen, Ben; Hoogeman, Mischa [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands)

    2014-04-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3

  18. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    International Nuclear Information System (INIS)

    Water, Steven van de; Valli, Lorella; Aluwini, Shafak; Lanconelli, Nico; Heijmen, Ben; Hoogeman, Mischa

    2014-01-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V 100% ) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm

  19. Kinematic analysis and simulation of a substation inspection robot guided by magnetic sensor

    Science.gov (United States)

    Xiao, Peng; Luan, Yiqing; Wang, Haipeng; Li, Li; Li, Jianxiang

    2017-01-01

    In order to improve the performance of the magnetic navigation system used by substation inspection robot, the kinematic characteristics is analyzed based on a simplified magnetic guiding system model, and then the simulation process is executed to verify the reasonability of the whole analysis procedure. Finally, some suggestions are extracted out, which will be helpful to guide the design of the inspection robot system in the future.

  20. A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Korhonen, Juha, E-mail: juha.p.korhonen@hus.fi [Clinical Research Institute Helsinki University Central Hospital Ltd., POB-700, 00029 HUS, Finland and Department of Oncology, Helsinki University Central Hospital, POB-180, 00029 HUS (Finland); Kapanen, Mika [Clinical Research Institute Helsinki University Central Hospital Ltd., POB-700, 00029 HUS (Finland); Department of Oncology, Helsinki University Central Hospital, POB-180, 00029 HUS (Finland); Department of Medical Physics, Tampere University Hospital, POB-2000, 33521 Tampere (Finland); Keyriläinen, Jani; Seppälä, Tiina; Tenhunen, Mikko [Department of Oncology, Helsinki University Central Hospital, POB-180, 00029 HUS (Finland)

    2014-01-15

    Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRI intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each

  1. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U.; Grobholz, R.; Heilmann, M.; Michel, M.S.; Trojan, L.; Werner, A.; Rabe, J.; Schlemmer, H.P.

    2003-01-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k ep ).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k ep . Prostate carcinomas of the peripheral zone were demarcated by amplitude and k ep . In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k ep and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k ep reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [de

  2. Changes in prostate shape and volume and their implications for radiotherapy after introduction of endorectal balloon as determined by MRI at 3T.

    NARCIS (Netherlands)

    Heijmink, S.W.T.P.J.; Scheenen, T.W.J.; Lin, E.N.J.T. van; Visser, A.G.; Kiemeney, L.A.L.M.; Witjes, J.A.; Barentsz, J.O.

    2009-01-01

    PURPOSE: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. METHODS AND MATERIALS: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T

  3. TU-CD-BRA-04: Evaluation of An Atlas-Based Segmentation Method for Prostate and Peripheral Zone Regions On MRI

    International Nuclear Information System (INIS)

    Nelson, AS; Piper, J; Curry, K; Swallen, A; Padgett, K; Pollack, A; Stoyanova, RS

    2015-01-01

    Purpose: Prostate MRI plays an important role in diagnosis, biopsy guidance, and therapy planning for prostate cancer. Prostate MRI contours can be used to aid in image fusion for ultrasound biopsy guidance and delivery of radiation. Our goal in this study is to evaluate an automatic atlas-based segmentation method for generating prostate and peripheral zone (PZ) contours on MRI. Methods: T2-weighted MRIs were acquired on 3T-Discovery MR750 System (GE, Milwaukee). The Volumes of Interest (VOIs): prostate and PZ were outlined by an expert radiation oncologist and used to create an atlas library for atlas-based segmentation. The atlas-segmentation accuracy was evaluated using a leave-one-out analysis. The method involved automatically finding the atlas subject that best matched the test subject followed by a normalized intensity-based free-form deformable registration of the atlas subject to the test subject. The prostate and PZ contours were transformed to the test subject using the same deformation. For each test subject the three best matches were used and the final contour was combined using Majority Vote. The atlas-segmentation process was fully automatic. Dice similarity coefficients (DSC) and mean Hausdorff values were used for comparison. Results: VOIs contours were available for 28 subjects. For the prostate, the atlas-based segmentation method resulted in an average DSC of 0.88+/−0.08 and a mean Hausdorff distance of 1.1+/−0.9mm. The number of patients (#) in DSC ranges are as follows: 0.60–0.69(1), 0.70–0.79(2), 0.80–0.89(13), >0.89(11). For the PZ, the average DSC was 0.72+/−0.17 and average Hausdorff of 0.9+/−0.9mm. The number of patients (#) in DSC ranges are as follows: 0.89(1). Conclusion: The MRI atlas-based segmentation method achieved good results for both the whole prostate and PZ compared to expert defined VOIs. The technique is fast, fully automatic, and has the potential to provide significant time savings for prostate VOI

  4. Multi-Channel RF System for MRI-Guided Transurethral Ultrasound Thermal Therapy

    Science.gov (United States)

    Yak, Nicolas; Asselin, Matthew; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound thermal therapy is an approach to treating localized prostate cancer which targets precise deposition of thermal energy within a confined region of the gland. This treatment requires a system incorporating a heating applicator with multiple planar ultrasound transducers and associated RF electronics to control individual elements independently in order to achieve accurate 3D treatment. We report the design, construction, and characterization of a prototype multi-channel system capable of controlling 16 independent RF signals for a 16-element heating applicator. The main components are a control computer, microcontroller, and a 16-channel signal generator with 16 amplifiers, each incorporating a low-pass filter and transmitted/reflected power detection circuit. Each channel can deliver from 0.5 to 10 W of electrical power and good linearity from 3 to 12 MHz. Harmonic RF signals near the Larmor frequency of a 1.5 T MRI were measured to be below -30 dBm and heating experiments within the 1.5 T MR system showed no significant decrease in SNR of the temperature images. The frequency and power for all 16 channels could be changed in less than 250 ms, which was sufficiently rapid for proper performance of the control algorithms. A common backplane design was chosen which enabled an inexpensive, modular approach for each channel resulting in an overall system with minimal footprint.

  5. Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Boudam, Karim; Pinter, Csaba; Kadoury, Samuel; Lasso, Andras; Fichtinger, Gabor; Ménard, Cynthia

    The objective of this study was to develop and validate an open-source module for MRI to transrectal ultrasound (TRUS) registration to support tumor-targeted prostate brachytherapy. In this study, 15 patients with prostate cancer lesions visible on multiparametric MRI were selected for the validation. T2-weighted images with 1-mm isotropic voxel size and diffusion weighted images were acquired on a 1.5T Siemens imager. Three-dimensional (3D) TRUS images with 0.5-mm slice thickness were acquired. The investigated registration module was incorporated in the open-source 3D Slicer platform, which can compute rigid and deformable transformations. An extension of 3D Slicer, SlicerRT, allows import of and export to DICOM-RT formats. For validation, similarity indices, prostate volumes, and centroid positions were determined in addition to registration errors for common 3D points identified by an experienced radiation oncologist. The average time to compute the registration was 35 ± 3 s. For the rigid and deformable registration, respectively, Dice similarity coefficients were 0.87 ± 0.05 and 0.93 ± 0.01 while the 95% Hausdorff distances were 4.2 ± 1.0 and 2.2 ± 0.3 mm. MRI volumes obtained after the rigid and deformable registration were not statistically different (p > 0.05) from reference TRUS volumes. For the rigid and deformable registration, respectively, 3D distance errors between reference and registered centroid positions were 2.1 ± 1.0 and 0.4 ± 0.1 mm while registration errors between common points were 3.5 ± 3.2 and 2.3 ± 1.1 mm. Deformable registration was found significantly better (p < 0.05) than rigid registration for all parameters. An open-source MRI to TRUS registration platform was validated for integration in the brachytherapy workflow. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: A deformable registration and validation study

    International Nuclear Information System (INIS)

    Lian, J.; Xing, L.; Hunjan, S.; Dumoulin, C.; Levin, J.; Lo, A.; Watkins, R.; Rohling, K.; Giaquinto, R.; Kim, D.; Spielman, D.; Daniel, B.

    2004-01-01

    The endorectal coil is being increasingly used in magnetic resonance imaging (MRI) and MR spectroscopic imaging (MRSI) to obtain anatomic and metabolic images of the prostate with high signal-to-noise ratio (SNR). In practice, however, the use of endorectal probe inevitably distorts the prostate and other soft tissue organs, making the analysis and the use of the acquired image data in treatment planning difficult. The purpose of this work is to develop a deformable image registration algorithm to map the MRI/MRSI information obtained using an endorectal probe onto CT images and to verify the accuracy of the registration by phantom and patient studies. A mapping procedure involved using a thin plate spline (TPS) transformation was implemented to establish voxel-to-voxel correspondence between a reference image and a floating image with deformation. An elastic phantom with a number of implanted fiducial markers was designed for the validation of the quality of the registration. Radiographic images of the phantom were obtained before and after a series of intentionally introduced distortions. After mapping the distorted phantom to the original one, the displacements of the implanted markers were measured with respect to their ideal positions and the mean error was calculated. In patient studies, CT images of three prostate patients were acquired, followed by 3 Tesla (3 T) MR images with a rigid endorectal coil. Registration quality was estimated by the centroid position displacement and image coincidence index (CI). Phantom and patient studies show that TPS-based registration has achieved significantly higher accuracy than the previously reported method based on a rigid-body transformation and scaling. The technique should be useful to map the MR spectroscopic dataset acquired with ER probe onto the treatment planning CT dataset to guide radiotherapy planning

  7. Evaluation of magnetic resonance imaging-based prostate-specific antigen density of the prostate in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Hoshii, Tatsuhiko; Nishiyama, Tsutomu; Toyabe, Shinichi; Akazawa, Kohei; Komatsu, Shuichi; Kaneko, Masaaki; Hara, Noboru; Takahashi, Kota

    2007-01-01

    We evaluated prostate-specific antigen (PSA) density of the prostatic volume (PSAD) estimated using transrectal ultrasonography (TRUS; TRUS-based PSAD), magnetic resonance imaging (MRI; MRI-based PSAD), and PSA density of the transition zone (TZ) volume (PSATZD) estimated using MRI (MRI-based PSATZD) in the diagnosis of prostate cancer (PCa). One hundred and twenty patients, who were suspected to have PCa based on PSA, ranged between 4.1 and 20.0 ng/mL were enrolled in this study. The prostatic volume estimated using TRUS was smaller than the volume estimated using MRI by 11.4% in the patients with PSA levels ranging 4.1-20.0 ng/mL, 7.2% in those 4.1-10.0 ng/mL, and 15.7% in those 10.1-20.0 ng/mL, respectively. PSA levels were correlated with the prostatic volume estimated using TRUS and MRI, and TZ volume estimated using MRI in the patients without PCa; however, the level was not correlated with them in the patients with PCa. The area under the receiver operating characteristic curve of MRI-based PSAD was higher than that of TRUS-based PSAD; however, there was no statistical difference. Stepwise logistic regression analysis for the prediction of PCa by using PSA-related parameters confirmed that MRI-based PSATZD was the most significant predictor in patients with PSA levels in the range of 4.1-20.0 ng/mL (P<0.001), the range of 4.1-10.0 ng/mL (P=0.002), and the range of 10.1-20.0 ng/mL (P<0.001), respectively. The prostatic volume estimated using TRUS was smaller than the volume estimated using MRI. MRI-based PSATZD is the most significant predictor in the four parameters. (author)

  8. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaofeng, E-mail: xyang43@emory.edu; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Curran, Walter J.; Liu, Tian [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia 30322 (United States); Mao, Hui [Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia 30322 (United States)

    2014-11-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  9. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Science.gov (United States)

    Yang, Xiaofeng; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2014-01-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  10. Five-year follow-up using a prostate stent as fiducial in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Carl, Jesper; Sander, Lotte

    2015-06-01

    To report results from the five-year follow-up on a previously reported study using image-guided radiotherapy (IGRT) of localized or locally advanced prostate cancer (PC) and a removable prostate stent as fiducial. Patients with local or locally advanced PC were treated using five-field 3D conformal radiotherapy (3DRT). The clinical target volumes (CTV) were treated to 78 Gy in 39 fractions using daily on-line image guidance (IG). Late genito-urinary (GU) and gastro-intestinal (GI) toxicities were scored using the radiotherapy oncology group (RTOG) score and the common toxicity score of adverse events (CTC) score. Urinary symptoms were also scored using the international prostate symptom score (IPSS). Median observation time was 5.4 year. Sixty-two of the 90 patients from the original study cohort were eligible for toxicity assessment. Overall survival, cancer-specific survival and biochemical freedom from failure were 85%, 96% and 80%, respectively at five years after radiotherapy. Late toxicity GU and GI RTOG scores≥2 were 5% and 0%. Comparing pre- and post-radiotherapy IPSS scores indicate that development in urinary symptoms after radiotherapy may be complex. Prostate image-guided radiotherapy using a prostate stent demonstrated survival data comparable with recently published data. GU and GI toxicities at five-year follow-up were low and comparable to the lowest toxicity rates reported. These findings support that the precision of the prostate stent technique is at least as good as other techniques. IPSS revealed a complex development in urinary symptoms after radiotherapy.

  11. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  12. Real-time virtual sonography for navigation during targeted prostate biopsy using magnetic resonance imaging data

    International Nuclear Information System (INIS)

    Miyagawa, Tomoaki; Ishikawa, Satoru; Kimura, Tomokazu; Suetomi, Takahiro; Tsutsumi, Masakazu; Irie, Toshiyuki; Kondoh, Masanao; Mitake, Tsuyoshi

    2010-01-01

    The objective of this study was to evaluate the effectiveness of the medical navigation technique, namely, Real-time Virtual Sonography (RVS), for targeted prostate biopsy. Eighty-five patients with suspected prostate cancer lesions using magnetic resonance imaging (MRI) were included in this study. All selected patients had at least one negative result on the previous transrectal biopsies. The acquired MRI volume data were loaded onto a personal computer installed with RVS software, which registers the volumes between MRI and real-time ultrasound data for real-time display. The registered MRI images were displayed adjacent to the ultrasonographic sagittal image on the same computer monitor. The suspected lesions on T2-weighted images were marked with a red circle. At first suspected lesions were biopsied transperineally under real-time navigation with RVS and then followed by the conventional transrectal and transperineal biopsy under spinal anesthesia. The median age of the patients was 69 years (56-84 years), and the prostate-specific antigen level and prostate volume were 9.9 ng/mL (4.0-34.2) and 37.2 mL (18-141), respectively. Prostate cancer was detected in 52 patients (61%). The biopsy specimens obtained using RVS revealed 45/52 patients (87%) positive for prostate cancer. A total of 192 biopsy cores were obtained using RVS. Sixty-two of these (32%) were positive for prostate cancer, whereas conventional random biopsy revealed cancer only in 75/833 (9%) cores (P<0.01). Targeted prostate biopsy with RVS is very effective to diagnose lesions detected with MRI. This technique only requires additional computer and RVS software and thus is cost-effective. Therefore, RVS-guided prostate biopsy has great potential for better management of prostate cancer patients. (author)

  13. WE-EF-BRD-01: Past, Present and Future: MRI-Guided Radiotherapy From 2005 to 2025

    Energy Technology Data Exchange (ETDEWEB)

    Lagendijk, J. [University Medical Center Utrecht (Netherlands)

    2015-06-15

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapy from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.

  14. Protocol for the realization of transrectal prostatic biopsy guided by ultrasound

    International Nuclear Information System (INIS)

    Arce Montero, Jairo

    2013-01-01

    A general protocol is proposed for the realization of the ultrasound-guided prostatic biopsy in patients with positive screening. The screening should be performed taking into account risk antecedents, rectal examination and prostate-specific antigen (PSA) levels in the patients. However, patients that have presented without alteration in the PSA and suspect rectal examination, should be considered for biopsy endorectal with ultrasound guidance even more with positive risk factors. The generalities of prostate cancer are described. The general prostatic anatomy and echographic are reviewed. The echographic technique is analyzed in the exploration endorectal. The echographic findings suspects of prostate cancer are characterized. The different biopsy sampling techniques are described; and based on appropriate knowledge of prostatic echographic anatomy, could increase the effectiveness in the early detection of prostate cancer in patients with positive screening. The complications derived from the process are enumerated. The final recommendations are noted on the protocol described [es

  15. Adaptation of a 3D prostate cancer atlas for transrectal ultrasound guided target-specific biopsy

    International Nuclear Information System (INIS)

    Narayanan, R; Suri, J S; Werahera, P N; Barqawi, A; Crawford, E D; Shinohara, K; Simoneau, A R

    2008-01-01

    Due to lack of imaging modalities to identify prostate cancer in vivo, current TRUS guided prostate biopsies are taken randomly. Consequently, many important cancers are missed during initial biopsies. The purpose of this study was to determine the potential clinical utility of a high-speed registration algorithm for a 3D prostate cancer atlas. This 3D prostate cancer atlas provides voxel-level likelihood of cancer and optimized biopsy locations on a template space (Zhan et al 2007). The atlas was constructed from 158 expert annotated, 3D reconstructed radical prostatectomy specimens outlined for cancers (Shen et al 2004). For successful clinical implementation, the prostate atlas needs to be registered to each patient's TRUS image with high registration accuracy in a time-efficient manner. This is implemented in a two-step procedure, the segmentation of the prostate gland from a patient's TRUS image followed by the registration of the prostate atlas. We have developed a fast registration algorithm suitable for clinical applications of this prostate cancer atlas. The registration algorithm was implemented on a graphical processing unit (GPU) to meet the critical processing speed requirements for atlas guided biopsy. A color overlay of the atlas superposed on the TRUS image was presented to help pick statistically likely regions known to harbor cancer. We validated our fast registration algorithm using computer simulations of two optimized 7- and 12-core biopsy protocols to maximize the overall detection rate. Using a GPU, patient's TRUS image segmentation and atlas registration took less than 12 s. The prostate cancer atlas guided 7- and 12-core biopsy protocols had cancer detection rates of 84.81% and 89.87% respectively when validated on the same set of data. Whereas the sextant biopsy approach without the utility of 3D cancer atlas detected only 70.5% of the cancers using the same histology data. We estimate 10-20% increase in prostate cancer detection rates

  16. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  17. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  18. Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy

    International Nuclear Information System (INIS)

    Quentin, Michael; Schimmoeller, Lars; Antoch, Gerald; Blondin, Dirk; Arsov, Christian; Rabenalt, Robert; Albers, Peter

    2014-01-01

    The evaluation of lesions detected in prostate magnetic resonance imaging (MRI) with increased signal intensity (SI) on high b-value diffusion-weighted images as a sign of malignancy. One hundred and three consecutive patients with prostate MRI examination and MRI-guided in-bore biopsy were retrospectively included in the study. MRI-guided in-bore biopsy histologically confirmed prostate cancer in 50 patients (n = 92 lesions). The other 53 patients (n = 122 lesions) had negative bioptical results. In patients with histologically confirmed prostate cancer, 46 of the 92 lesions had visually increased SI on the high b-value images compared with the peripheral zone (SI = +27 ± 16%) or the central gland (SI = +37 ± 19%, P < 0.001 respectively). In patients with a negative biopsy, ten of the 122 lesions had visually increased SI (compared with the peripheral zone, SI = +29 ± 18%, and with the central gland, SI = +41 ± 15%, P < 0.001 respectively). Neither the apparent diffusion coefficient (ADC) values nor the Gleason Score of lesions with increased SI were significantly different from lesions without increased SI. Visually increased SI on the high b-value images of diffusion-weighted imaging using standard b-values is a sign of malignancy but can occasionally also be a feature of benign lesions. However, it does not indicate more aggressive tumours. (orig.)

  19. Interventional robotic systems: Applications and technology state-of-the-art

    Science.gov (United States)

    CLEARY, KEVIN; MELZER, ANDREAS; WATSON, VANCE; KRONREIF, GERNOT; STOIANOVICI, DAN

    2011-01-01

    Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere. PMID:16754193

  20. Comparing Three Different Techniques for Magnetic Resonance Imaging-targeted Prostate Biopsies : A Systematic Review of In-bore versus Magnetic Resonance Imaging-transrectal Ultrasound fusion versus Cognitive Registration. Is There a Preferred Technique?

    NARCIS (Netherlands)

    Wegelin, Olivier; Melick, H.H.E.; Hooft, Lotty; Bosch, J L H Ruud; Reitsma, Hans B; Barentsz, Jelle O; Somford, Diederik M

    CONTEXT: The introduction of magnetic resonance imaging-guided biopsies (MRI-GB) has changed the paradigm concerning prostate biopsies. Three techniques of MRI-GB are available: (1) in-bore MRI target biopsy (MRI-TB), (2) MRI-transrectal ultrasound fusion (FUS-TB), and (3) cognitive registration

  1. Urethrogram-directed Stereotactic Body Radiation Therapy (SBRT for Clinically Localized Prostate Cancer in Patients with Contraindications to Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Ima ePaydar

    2015-09-01

    Full Text Available Purpose: Magnetic resonance imaging (MRI-directed stereotactic body radiation therapy (SBRT has been established as a safe and effective treatment for prostate cancer. For patients with contraindications to MRI, CT-urethrogram is an alternative imaging approach to identify the location of the prostatic apex to guide treatment. This study sought to evaluate the safety of urethrogram-directed SBRT for prostate cancer.Methods: Between February 2009 and January 2014, 31 men with clinically localized prostate cancer were treated definitively with urethrogram-directed SBRT with or without supplemental intensity modulated radiation therapy (IMRT at Georgetown University Hospital. SBRT was delivered either as a primary treatment of 35-36.25 Gray (Gy in 5 fractions or as a boost of 19.5 Gy in 3 fractions followed by supplemental conventionally fractionated intensity modulated radiation therapy (45-50.4 Gy. Toxicities were recorded and scored using the Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v.4.0.Results: The median patient age was 70 years with a median prostate volume of 38 cc. The median follow-up was 3.7 years. The patients were elderly (Median age = 70, and comorbidities were common (Carlson Comorbidity Index > 2 in 36%. 71% of patients utilized alpha agonists prior to treatment, and 9.7% had prior procedures for benign prostatic hyperplasia (BPH. The 3-year actuarial incidence rates of > Grade 3 GU toxicity and > Grade 2 GI toxicity were 3.2% and 9.7%, respectively. There were no Grade 4 or 5 toxicities.Conclusions: MRI is the preferred imaging modality to guide prostate SBRT treatment. However, urethrogram-directed SBRT is a safe alternative for the treatment of patients with prostate cancer who are unable to undergo MRI.

  2. MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: Quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Scherr, M.K., E-mail: michael.scherr@med.uni-muenchen.de [Institute of Clinical Radiology, University of Munich, Munich (Germany); Seitz, M. [Department of Urology, University of Munich, Munich (Germany); Mueller-Lisse, U.G. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Ingrisch, M. [Josef Lissner Laboratory for Biomedical Imaging, Institute of Clinical Radiology, University of Munich, Munich (Germany); Reiser, M.F. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Mueller-Lisse, U.L. [Department of Urology, University of Munich, Munich (Germany)

    2010-12-15

    Background: Various MR methods, including MR-spectroscopy (MRS), dynamic, contrast-enhanced MRI (DCE-MRI), and diffusion-weighted imaging (DWI) have been applied to improve test quality of standard MRI of the prostate. Purpose: To determine if quantitative, model-based MR-perfusion (MRP) with gadobenate dimeglumine (Gd-BOPTA) discriminates between prostate cancer, benign tissue, and transitional zone (TZ) tissue. Material and methods: 27 patients (age, 65 {+-} 4 years; PSA 11.0 {+-} 6.1 ng/ml) with clinical suspicion of prostate cancer underwent standard MRI, 3D MR-spectroscopy (MRS), and MRP with Gd-BOPTA. Based on results of combined MRI/MRS and subsequent guided prostate biopsy alone (17/27), biopsy and radical prostatectomy (9/27), or sufficient negative follow-up (7/27), maps of model-free, deconvolution-based mean transit time (dMTT) were generated for 29 benign regions (bROIs), 14 cancer regions (cROIs), and 18 regions of transitional zone (tzROIs). Applying a 2-compartment exchange model, quantitative perfusion analysis was performed including as parameters: plasma flow (PF), plasma volume (PV), plasma mean transit time (PMTT), extraction flow (EFL), extraction fraction (EFR), interstitial volume (IV) and interstitial mean transit time (IMTT). Two-sided T-tests (significance level p < 0.05) discriminated bROIs vs. cROIs and cROIs vs. tzROIs, respectively. Results: PMTT discriminated best between bROIs (11.8 {+-} 3.0 s) and cROIs (24.3 {+-} 9.6 s) (p < 0.0001), while PF, PV, PS, EFR, IV, IMTT also differed significantly (p 0.00002-0.0136). Discrimination between cROIs and tzROIs was insignificant for all parameters except PV (14.3 {+-} 2.5 ml vs. 17.6 {+-} 2.6 ml, p < 0.05). Conclusions: Besides MRI, MRS and DWI quantitative, 2-compartment MRP with Gd-BOPTA discriminates between prostate cancer and benign tissue with several parameters. However, distinction of prostate cancer and TZ does not appear to be reliable.

  3. Intracavitary ultrasound phased arrays for prostate thermal therapies: MRI compatibility and in vivo testing.

    Science.gov (United States)

    Hutchinson, E B; Hynynen, K

    1998-12-01

    A 62 element MRI-compatible linear phased array was designed and constructed to investigate the feasibility of using transrectal ultrasound for the thermal therapeutic treatment of prostate cancer and benign prostatic hyperplasia. An aperiodic design technique developed in a previous study was used in the design of this array, which resulted in reduced grating lobe levels by using an optimized random distribution of unequally sized elements. The element sizes used in this array were selected to be favorable for both grating lobe levels as determined by array aperiodicity and array efficiency as determined by width to thickness ratios. The heating capabilities and MRI compatibility of the array were tested with in vivo rabbit thigh muscle heating experiments using MRI temperature monitoring. The array produced therapeutic temperature elevations in vivo at depths of 3-6 cm and axial locations up to 3 cm off the central axis and increased the size of the heated volume with electronic scanning of a single focus. The ability of this array to be used for ultrasound surgery was demonstrated by creating necrosed tissue lesions in vivo using short high-power sonications. The ability of the array to be used for hyperthermia was demonstrated by inducing therapeutic temperature elevations for longer exposures. Based on the acoustic and heating performance of this array, it has the potential to be clinically useful for delivering thermal therapies to the prostate and other target volumes close to body cavities.

  4. Feasibility Study of a Hand Guided Robotic Drill for Cochleostomy

    Directory of Open Access Journals (Sweden)

    Peter Brett

    2014-01-01

    Full Text Available The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  5. Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer

    Directory of Open Access Journals (Sweden)

    Metha Maenhout

    2017-04-01

    Full Text Available Purpose : Salvage treatments for localized radiorecurrent prostate cancer can be performed safely when a focal and image guided approach is used. Due to the low toxicity, the opportunity exists to investigate a second salvage treatment when a second locally recurrent prostate cancer occurs. Here, we describe a second salvage treatment procedure of 4 patients. Material and methods : Four patients with a pathologically proven second local recurrence were treated in an outpatient magnetic resonance imaging (MRI-guided setting with a single fraction of 19 Gy focal high-dose-rate brachytherapy (HDR-BT. Delineation was performed using choline-PET-CT or a 68Ga-PSMA PET in combination with multiparametric 3 Tesla MRI in all four patients. Toxicity was measured using common toxicity criteria for adverse events (CTCAE version 4.0. Results : With a median follow-up of 12 months (range, 6-15, there were 2 patients with biochemical recurrence as defined by the Phoenix-definition. There were no patients with grade 3 or more toxicity. In all second salvage HDR-BT treatments, the constraints for rectum, bladder, and urethra were met. Median treatment volume (GTV was 4.8 cc (range, 1.9-6.6 cc. A median of 8 catheters (range, 6-9 were used, and the median dose to the treatment volume (GTV was a D95: 19.3 Gy (SD 15.5-19.4 Gy. Conclusions : Second focal salvage MRI-guided HDR-BT for a select group of patients with a second locally recurrent prostate cancer is feasible. There was no grade 3 or more acute toxicity for these four patients.

  6. Efficient 3D multi-region prostate MRI segmentation using dual optimization.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    Efficient and accurate extraction of the prostate, in particular its clinically meaningful sub-regions from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, we propose a novel multi-region segmentation approach to simultaneously locating the boundaries of the prostate and its two major sub-regions: the central gland and the peripheral zone. The proposed method utilizes the prior knowledge of the spatial region consistency and employs a customized prostate appearance model to simultaneously segment multiple clinically meaningful regions. We solve the resulted challenging combinatorial optimization problem by means of convex relaxation, for which we introduce a novel spatially continuous flow-maximization model and demonstrate its duality to the investigated convex relaxed optimization problem with the region consistency constraint. Moreover, the proposed continuous max-flow model naturally leads to a new and efficient continuous max-flow based algorithm, which enjoys great advantages in numerics and can be readily implemented on GPUs. Experiments using 15 T2-weighted 3D prostate MR images, by inter- and intra-operator variability, demonstrate the promising performance of the proposed approach.

  7. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  8. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

    International Nuclear Information System (INIS)

    Ghose, Soumya; Mitra, Jhimli; Rivest-Hénault, David; Fazlollahi, Amir; Fripp, Jurgen; Dowling, Jason A.; Stanwell, Peter; Pichler, Peter; Sun, Jidi; Greer, Peter B.

    2016-01-01

    Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold

  9. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

    Energy Technology Data Exchange (ETDEWEB)

    Ghose, Soumya, E-mail: soumya.ghose@case.edu; Mitra, Jhimli [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 and CSIRO Health and Biosecurity, The Australian e-Health & Research Centre, Herston, QLD 4029 (Australia); Rivest-Hénault, David; Fazlollahi, Amir; Fripp, Jurgen; Dowling, Jason A. [CSIRO Health and Biosecurity, The Australian e-Health & Research Centre, Herston, QLD 4029 (Australia); Stanwell, Peter [School of health sciences, The University of Newcastle, Newcastle, NSW 2308 (Australia); Pichler, Peter [Department of Radiation Oncology, Cavalry Mater Newcastle Hospital, Newcastle, NSW 2298 (Australia); Sun, Jidi; Greer, Peter B. [School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, NSW 2308, Australia and Department of Radiation Oncology, Cavalry Mater Newcastle Hospital, Newcastle, NSW 2298 (Australia)

    2016-05-15

    Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold

  10. Zinc-sensitive MRI contrast agent detects differential release of Zn(II) ions from the healthy vs. malignant mouse prostate.

    Science.gov (United States)

    Clavijo Jordan, M Veronica; Lo, Su-Tang; Chen, Shiuhwei; Preihs, Christian; Chirayil, Sara; Zhang, Shanrong; Kapur, Payal; Li, Wen-Hong; De Leon-Rodriguez, Luis M; Lubag, Angelo J M; Rofsky, Neil M; Sherry, A Dean

    2016-09-13

    Many secretory tissues release Zn(II) ions along with other molecules in response to external stimuli. Here we demonstrate that secretion of Zn(II) ions from normal, healthy prostate tissue is stimulated by glucose in fasted mice and that release of Zn(II) can be monitored by MRI. An ∼50% increase in water proton signal enhancement is observed in T1-weighted images of the healthy mouse prostate after infusion of a Gd-based Zn(II) sensor and an i.p. bolus of glucose. Release of Zn(II) from intracellular stores was validated in human epithelial prostate cells in vitro and in surgically exposed prostate tissue in vivo using a Zn(II)-sensitive fluorescent probe known to bind to the extracellular surface of cells. Given the known differences in intracellular Zn(II) stores in healthy versus malignant prostate tissues, the Zn(II) sensor was then evaluated in a transgenic adenocarcinoma of the mouse prostate (TRAMP) model in vivo. The agent proved successful in detecting small malignant lesions as early as 11 wk of age, making this noninvasive MR imaging method potentially useful for identifying prostate cancer in situations where it may be difficult to detect using current multiparametric MRI protocols.

  11. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology

    Science.gov (United States)

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody

    2015-01-01

    Purpose Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Material and methods Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: 125I fixed spacing, 125I variable spacing, 103Pd fixed spacing, and 103Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. Results All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with 103Pd, and 0.007 and 0.029 with 125I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with 103Pd, and 0.012 and 0.037 with 125I plans. Conclusions The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy. PMID:26622227

  12. The new era of minimally invasive interventions for prostate cancer: robot-assisted laparoscopic radical prostatectomy and focal therapy

    Directory of Open Access Journals (Sweden)

    Schatloff O

    2011-10-01

    Full Text Available Oscar Schatloff1, Alyssa S Louis2, Uri Lindner21Global Robotics Institute, Florida Hospital Celebration Health, Celebration, FL, USA; 2Division of Urology, Department of Surgical Oncology, University Health Network, Toronto, ON, CanadaAbstract: Prostate cancer remains a common but highly treatable disease. Innovations in prostate cancer treatment have allowed a transition toward minimally invasive approaches in an attempt to avoid treatment-related morbidities. In the middle of the treatment spectrum between radical open surgeries and active surveillance lies robot-assisted laparoscopic radical prostatectomy (RALP and focal therapy (FT. This review sets out the most current information on RALP and FT (including laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, and irreversible electroporation.Keywords: PCa, RALP, FT, laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, irreversible electroporation

  13. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  14. Unshielded asymmetric transmit-only and endorectal receive-only radiofrequency coil for (23) Na MRI of the prostate at 3 tesla.

    Science.gov (United States)

    Farag, Adam; Peterson, Justin Charles; Szekeres, Trevor; Bauman, Glenn; Chin, Joseph; Romagnoli, Cesare; Bartha, Robert; Scholl, Timothy J

    2015-08-01

    To develop and optimize radiofrequency (RF) hardware for the detection of endogenous sodium ((23) Na) by 3.0 Tesla (T) MRI in the human prostate. A transmit-only receive-only (TORO) RF system of resonators consisting of an unshielded, asymmetric, quadrature birdcage (transmit), and an endorectal (ER), linear, surface (receive) coil were developed and tested on a 3T MRI scanner. Two different ER receivers were constructed; a single-tuned ((23) Na) and a dual-tuned ((1) H/(23) Na). Both receivers were evaluated by the measurements of signal-to-noise ratio (SNR) and B1 homogeneity. For tissue sodium concentration (TSC) quantification, vials containing known sodium concentrations were incorporated into the ER. The system was used to measure the prostate TSC of three men (age 55 ± 5 years) with biopsy-proven prostate cancer. B1 field inhomogeneity of the asymmetric transmitter was estimated to be less than 5%. The mean SNR measured in a region of interest within the prostate using the single-tuned ER coil was 54.0 ± 4.6. The mean TSC in the central gland was 60.2 ± 5.7 mmol/L and in the peripheral gland was 70.5 ± 9.0 mmol/L. A TORO system was developed and optimized for (23) Na MRI of the human prostate which showed good sensitivity throughout the prostate for quantitative measurement of TSC. © 2014 Wiley Periodicals, Inc.

  15. TU-CD-BRA-04: Evaluation of An Atlas-Based Segmentation Method for Prostate and Peripheral Zone Regions On MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, AS; Piper, J; Curry, K; Swallen, A [MIM Software Inc., Cleveland, OH (United States); Padgett, K; Pollack, A; Stoyanova, RS [University of Miami, Miami, FL (United States)

    2015-06-15

    Purpose: Prostate MRI plays an important role in diagnosis, biopsy guidance, and therapy planning for prostate cancer. Prostate MRI contours can be used to aid in image fusion for ultrasound biopsy guidance and delivery of radiation. Our goal in this study is to evaluate an automatic atlas-based segmentation method for generating prostate and peripheral zone (PZ) contours on MRI. Methods: T2-weighted MRIs were acquired on 3T-Discovery MR750 System (GE, Milwaukee). The Volumes of Interest (VOIs): prostate and PZ were outlined by an expert radiation oncologist and used to create an atlas library for atlas-based segmentation. The atlas-segmentation accuracy was evaluated using a leave-one-out analysis. The method involved automatically finding the atlas subject that best matched the test subject followed by a normalized intensity-based free-form deformable registration of the atlas subject to the test subject. The prostate and PZ contours were transformed to the test subject using the same deformation. For each test subject the three best matches were used and the final contour was combined using Majority Vote. The atlas-segmentation process was fully automatic. Dice similarity coefficients (DSC) and mean Hausdorff values were used for comparison. Results: VOIs contours were available for 28 subjects. For the prostate, the atlas-based segmentation method resulted in an average DSC of 0.88+/−0.08 and a mean Hausdorff distance of 1.1+/−0.9mm. The number of patients (#) in DSC ranges are as follows: 0.60–0.69(1), 0.70–0.79(2), 0.80–0.89(13), >0.89(11). For the PZ, the average DSC was 0.72+/−0.17 and average Hausdorff of 0.9+/−0.9mm. The number of patients (#) in DSC ranges are as follows: <0.60(4), 0.60–0.69(6), 0.70–0.79(7), 0.80–0.89(9), >0.89(1). Conclusion: The MRI atlas-based segmentation method achieved good results for both the whole prostate and PZ compared to expert defined VOIs. The technique is fast, fully automatic, and has the potential

  16. TU-AB-201-11: A Novel Theoretical Framework for MRI-Only Image Guided LDR Prostate and Breast Brachytherapy Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, A; Elzibak, A; Fatemi, A; Safigholi, H; Ravi, A; Morton, G; Song, W [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Han, D [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To propose a novel framework for accurate model-based dose calculations using only MR images for LDR prostate and breast seed implant brachytherapy. Methods: Model-based dose calculation methodologies recommended by TG-186 require further knowledge about specific tissue composition, which is challenging with MRI. However, relying on MRI-only for implant dosimetry would reduce the soft tissue delineation uncertainty, costs, and uncertainties associated with multi-modality registration and fusion processes. We propose a novel framework to address this problem using quantitative MRI acquisitions and reconstruction techniques. The framework includes three steps: (1) Identify the locations of seeds(2) Identify the presence (or absence) of calcification(s)(3) Quantify the water and fat content in the underlying tissueSteps (1) and (2) consider the sources that limit patient dosimetry, particularly the inter-seed attenuation and the calcified regions; while step (3) targets the quantification of the tissue composition to consider the heterogeneities in the medium. Our preliminary work has shown that the seeds and the calcifications can be identified with MRI using both the magnitude and the phase images. By employing susceptibility-weighted imaging with specific post-processing techniques, the phase images can be further explored to distinguish the seeds from the calcifications. Absolute quantification of tissue, water, and fat content is feasible and was previously demonstrated in phantoms and in-vivo applications, particularly for brain diseases. The approach relies on the proportionality of the MR signal to the number of protons in an image volume. By employing appropriate correction algorithms for T1 - and T2*-related biases, B1 transmit and receive field inhomogeneities, absolute water/fat content can be determined. Results: By considering calcification and interseed attenuation, and through the knowledge of water and fat mass density, accurate patient

  17. Supervised Remote Robot with Guided Autonomy and Teleoperation (SURROGATE): A Framework for Whole-Body Manipulation

    Science.gov (United States)

    Hebert, Paul; Ma, Jeremy; Borders, James; Aydemir, Alper; Bajracharya, Max; Hudson, Nicolas; Shankar, Krishna; Karumanchi, Sisir; Douillard, Bertrand; Burdick, Joel

    2015-01-01

    The use of the cognitive capabilties of humans to help guide the autonomy of robotics platforms in what is typically called "supervised-autonomy" is becoming more commonplace in robotics research. The work discussed in this paper presents an approach to a human-in-the-loop mode of robot operation that integrates high level human cognition and commanding with the intelligence and processing power of autonomous systems. Our framework for a "Supervised Remote Robot with Guided Autonomy and Teleoperation" (SURROGATE) is demonstrated on a robotic platform consisting of a pan-tilt perception head, two 7-DOF arms connected by a single 7-DOF torso, mounted on a tracked-wheel base. We present an architecture that allows high-level supervisory commands and intents to be specified by a user that are then interpreted by the robotic system to perform whole body manipulation tasks autonomously. We use a concept of "behaviors" to chain together sequences of "actions" for the robot to perform which is then executed real time.

  18. SU-D-207A-03: Potential Role of BOLD MRI in Discrimination of Aggressive Tumor Habitat in Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ford, J; Lopez, C; Tschudi, Y; Breto, A; Padgett, K; Pollack, A; Stoyanova, R [University of Miami Miller School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To determine whether blood oxygenation level dependent (BOLD) MRI signal measured in prostate cancer patients, in addition to quantitative diffusion and perfusion parameters from multiparametric (mp)MRI exams, can help discriminate aggressive and/or radioresistant lesions. Methods: Several ongoing clinical trials in our institution require mpMRI exam to determine eligibility (presence of identifiable tumor lesion on mpMRI) and prostate volumes for dose escalation. Upon consent, patients undergo fiducial markers placement and a T2*-weighted imaging at the time of CT sim to facilitate the fusion. In a retrospective analysis eleven clinical trial patients were identified who had undergone mpMRI on GE 3T magnet, followed by T2*-weighted imaging (time-period mean±SD = 48±20 days) using a consistent protocol (gradient echo, TR/TE=30/11.8ms, flip angle=12, matrix=256×256×75, voxel size=1.25×1.25×2.5mm). ROIs for prostate tumor lesions were automatically determined using ADC threshold ≤1200 µm2/s. Although the MR protocol was not intended for BOLD analysis, we utilized the T2*-weighted signal normalized to that in nearby muscle; likewise, T2-weighted lesion signal was normalized to muscle, following rigid registration of the T2 to T2* images. The ratio of these normalized signals, T2*/T2, is a measure of BOLD effect in the prostate tumors. Perfusion parameters (Ktrans, ve, kep) were also calculated. Results: T2*/T2 (mean±SE) was found to be substantially lower for Gleason score (GS) 8&9 (0.82±0.04) compared to GS 7 (1.08±0.07). A k-means cluster analysis of T2*/T2 versus kep = Ktrans/ve revealed two distinct clusters, one with higher T2*/T2 and lower kep, containing only GS 7 lesions, and another with lower T2*/T2 and higher kep, associated with tumor aggressiveness. This latter cluster contained all GS 8&9 lesions, as well as some GS 7. Conclusion: BOLD MRI, in addition to ADC and kep, may play a role (perhaps orthogonal to Gleason score) in

  19. Remote-controlled vision-guided mobile robot system

    Science.gov (United States)

    Ande, Raymond; Samu, Tayib; Hall, Ernest L.

    1997-09-01

    Automated guided vehicles (AGVs) have many potential applications in manufacturing, medicine, space and defense. The purpose of this paper is to describe exploratory research on the design of the remote controlled emergency stop and vision systems for an autonomous mobile robot. The remote control provides human supervision and emergency stop capabilities for the autonomous vehicle. The vision guidance provides automatic operation. A mobile robot test-bed has been constructed using a golf cart base. The mobile robot (Bearcat) was built for the Association for Unmanned Vehicle Systems (AUVS) 1997 competition. The mobile robot has full speed control with guidance provided by a vision system and an obstacle avoidance system using ultrasonic sensors systems. Vision guidance is accomplished using two CCD cameras with zoom lenses. The vision data is processed by a high speed tracking device, communicating with the computer the X, Y coordinates of blobs along the lane markers. The system also has three emergency stop switches and a remote controlled emergency stop switch that can disable the traction motor and set the brake. Testing of these systems has been done in the lab as well as on an outside test track with positive results that show that at five mph the vehicle can follow a line and at the same time avoid obstacles.

  20. MRI simulation: end-to-end testing for prostate radiation therapy using geometric pelvic MRI phantoms

    International Nuclear Information System (INIS)

    Sun, Jidi; Menk, Fred; Lambert, Jonathan; Martin, Jarad; Denham, James W; Greer, Peter B; Dowling, Jason; Rivest-Henault, David; Pichler, Peter; Parker, Joel; Arm, Jameen; Best, Leah

    2015-01-01

    To clinically implement MRI simulation or MRI-alone treatment planning requires comprehensive end-to-end testing to ensure an accurate process. The purpose of this study was to design and build a geometric phantom simulating a human male pelvis that is suitable for both CT and MRI scanning and use it to test geometric and dosimetric aspects of MRI simulation including treatment planning and digitally reconstructed radiograph (DRR) generation.A liquid filled pelvic shaped phantom with simulated pelvic organs was scanned in a 3T MRI simulator with dedicated radiotherapy couch-top, laser bridge and pelvic coil mounts. A second phantom with the same external shape but with an internal distortion grid was used to quantify the distortion of the MR image. Both phantoms were also CT scanned as the gold-standard for both geometry and dosimetry. Deformable image registration was used to quantify the MR distortion. Dose comparison was made using a seven-field IMRT plan developed on the CT scan with the fluences copied to the MR image and recalculated using bulk electron densities.Without correction the maximum distortion of the MR compared with the CT scan was 7.5 mm across the pelvis, while this was reduced to 2.6 and 1.7 mm by the vendor’s 2D and 3D correction algorithms, respectively. Within the locations of the internal organs of interest, the distortion was <1.5 and <1 mm with 2D and 3D correction algorithms, respectively. The dose at the prostate isocentre calculated on CT and MRI images differed by 0.01% (1.1 cGy). Positioning shifts were within 1 mm when setup was performed using MRI generated DRRs compared to setup using CT DRRs.The MRI pelvic phantom allows end-to-end testing of the MRI simulation workflow with comparison to the gold-standard CT based process. MRI simulation was found to be geometrically accurate with organ dimensions, dose distributions and DRR based setup within acceptable limits compared to CT. (paper)

  1. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    Science.gov (United States)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  2. Imaging and intervention in prostate cancer: Current perspectives and future trends

    Directory of Open Access Journals (Sweden)

    Sanjay Sharma

    2014-01-01

    Full Text Available Prostate cancer is the commonest malignancy in men that causes significant morbidity and mortality worldwide. Screening by digital rectal examination (DRE and serum prostate-specific antigen (PSA is used despite its limitations. Gray-scale transrectal ultrasound (TRUS, used to guide multiple random prostatic biopsies, misses up to 20% cancers and frequently underestimates the grade of malignancy. Increasing the number of biopsy cores marginally increases the yield. Evolving techniques of real-time ultrasound elastography (RTE and contrast-enhanced ultrasound (CEUS are being investigated to better detect and improve the yield by allowing "targeted" biopsies. Last decade has witnessed rapid developments in magnetic resonance imaging (MRI for improved management of prostate cancer. In addition to the anatomical information, it is capable of providing functional information through diffusion-weighted imaging (DWI, magnetic resonance spectroscopy (MRS, and dynamic contrast-enhanced (DCE MRI. Multi-parametric MRI has the potential to exclude a significant cancer in majority of cases. Inclusion of MRI before prostatic biopsy can reduce the invasiveness of the procedure by limiting the number of cores needed to make a diagnosis and support watchful waiting in others. It is made possible by targeted biopsies as opposed to random. With the availability of minimally invasive therapeutic modalities like high-intensity focused ultrasound (HIFU and interstitial laser therapy, detecting early cancer is even more relevant today. [18F]--fluorodeoxyglucose positron emission tomography/computed tomography ( 18 FDG PET/CT has no role in the initial evaluation of prostate cancer. Choline PET has been recently found to be more useful. Fluoride-PET has a higher sensitivity and resolution than a conventional radionuclide bone scan in detecting skeletal metastases.

  3. Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, T.; Quentin, M.; Schmaltz, A.K.; Rubbert, C.; Blondin, D.; Antoch, G.; Schimmoeller, L. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, C.; Rabenalt, R.; Albers, P. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2018-01-15

    To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients and acute; weight, and (3) prostate volume. In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. (orig.)

  4. Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate

    International Nuclear Information System (INIS)

    Ullrich, T.; Quentin, M.; Schmaltz, A.K.; Rubbert, C.; Blondin, D.; Antoch, G.; Schimmoeller, L.; Arsov, C.; Rabenalt, R.; Albers, P.

    2018-01-01

    To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients and acute; weight, and (3) prostate volume. In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. (orig.)

  5. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis

    2013-06-01

    In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  6. Organ-confined prostate cancer: effect of prior transrectal biopsy on endorectal MRI and MR spectroscopic imaging

    International Nuclear Information System (INIS)

    Qayyum, Aliya; Coakley, F.V.; Lu, Y.; Olpin, J.D.; Wu, L.; Yeh, B.M.; Carroll, P.R.; Kurhanewicz, J.

    2004-01-01

    Objective: Our aim was to determine the effect of prior transrectal biopsy on endorectal MRI and MR spectroscopic imaging findings in patients with organ-confined prostate cancer. Materials and Methods: Endorectal MRI and MR spectroscopic imaging were performed in 43 patients with biopsy-proven prostate cancer before radical prostatectomy confirming organ-confined disease. For each sextant, two independent reviewers scored the degree of hemorrhage on a scale from 1 to 5 and recorded the presence or absence of capsular irregularity. A spectroscopist recorded the number of spectrally degraded voxels in the peripheral zone. The outcome variables of capsular irregularity and spectral degradation were correlated with the predictor variables of time from biopsy and degree of hemorrhage after biopsy. Results: Capsular irregularity was unrelated to time from biopsy or to degree of hemorrhage. Spectral degradation was inversely related to time from biopsy (p < 0.01); the mean percentage of degraded peripheral zone voxels was 18.5% within 8 weeks of biopsy compared with 7% after 8 weeks. Spectral degradation was unrelated to the degree of hemorrhage. Conclusion: In organ-confined prostate cancer, capsular irregularity can be seen at any time after biopsy and is independent of the degree of hemorrhage, whereas spectral degradation is seen predominantly in the first 8 weeks after biopsy. MRI staging criteria and guidelines for scheduling studies after biopsy may require appropriate modification. (author)

  7. Store-Carry and Forward-Type M2M Communication Protocol Enabling Guide Robots to Work together and the Method of Identifying Malfunctioning Robots Using the Byzantine Algorithm

    Directory of Open Access Journals (Sweden)

    Yoshio Suga

    2016-11-01

    Full Text Available This paper concerns a service in which multiple guide robots in an area display arrows to guide individual users to their destinations. It proposes a method of identifying malfunctioning robots and robots that give wrong directions to users. In this method, users’ mobile terminals and robots form a store-carry and forward-type M2M communication network, and a distributed cooperative protocol is used to enable robots to share information and identify malfunctioning robots using the Byzantine algorithm. The robots do not directly communicate with each other, but through users’ mobile terminals. We have introduced the concept of the quasi-synchronous number, so whether a certain robot is malfunctioning can be determined even when items of information held by all of the robots are not synchronized. Using simulation, we have evaluated the proposed method in terms of the rate of identifying malfunctioning robots, the rate of reaching the destination and the average length of time to reach the destination.

  8. Prostate ultrasound: back in business!

    Science.gov (United States)

    Crisan, Nicolae; Andras, Iulia; Radu, Corina; Andras, David; Coman, Radu-Tudor; Tucan, Paul; Pisla, Doina; Crisan, Dana; Coman, Ioan

    2017-11-29

    The use of grey scale prostate ultrasound decreased after the implementation of magnetic resonance imaging (MRI) for the diagnosis and evaluation of prostate cancer. The new developments, such as multiparametric ultrasound and MRI-ultrasound fusion technology, renewed the interest for this imaging method in the assessment of prostate cancer. The purpose of this paper was to review the current role of prostate ultrasound in the setting of these new applications. A thorough reevaluation of the selection criteria of the patients is required to assess which patients would benefit from multiparametric ultrasound, who wouldbenefit from multiparametric MRI or the combination of both to assist prostate biopsy in order to ensure the balance between overdiagnosis and underdiagnosis of prostate cancer.

  9. A software tool for advanced MRgFUS prostate therapy planning and follow up

    Science.gov (United States)

    van Straaten, Dörte; Hoogenboom, Martijn; van Amerongen, Martinus J.; Weiler, Florian; Issawi, Jumana Al; Günther, Matthias; Fütterer, Jurgen; Jenne, Jürgen W.

    2017-03-01

    US guided HIFU/FUS ablation for the therapy of prostate cancer is a clinical established method, while MR guided HIFU/FUS applications for prostate recently started clinical evaluation. Even if MRI examination is an excellent diagnostic tool for prostate cancer, it is a time consuming procedure and not practicable within an MRgFUS therapy session. The aim of our ongoing work is to develop software to support therapy planning and post-therapy follow-up for MRgFUS on localized prostate cancer, based on multi-parametric MR protocols. The clinical workflow of diagnosis, therapy and follow-up of MR guided FUS on prostate cancer was deeply analyzed. Based on this, the image processing workflow was designed and all necessary components, e.g. GUI, viewer, registration tools etc. were defined and implemented. The software bases on MeVisLab with several implemented C++ modules for the image processing tasks. The developed software, called LTC (Local Therapy Control) will register and visualize automatically all images (T1w, T2w, DWI etc.) and ADC or perfusion maps gained from the diagnostic MRI session. This maximum of diagnostic information helps to segment all necessary ROIs, e.g. the tumor, for therapy planning. Final therapy planning will be performed based on these segmentation data in the following MRgFUS therapy session. In addition, the developed software should help to evaluate the therapy success, by synchronization and display of pre-therapeutic, therapy and follow-up image data including the therapy plan and thermal dose information. In this ongoing project, the first stand-alone prototype was completed and will be clinically evaluated.

  10. Certificate of need legislation and the dissemination of robotic surgery for prostate cancer.

    Science.gov (United States)

    Jacobs, Bruce L; Zhang, Yun; Skolarus, Ted A; Wei, John T; Montie, James E; Schroeck, Florian R; Hollenbeck, Brent K

    2013-01-01

    The uncertainty about the incremental benefit of robotic prostatectomy and its higher associated costs makes it an ideal target for state based certificate of need laws, which have been enacted in several states. We studied the relationship between certificate of need laws and market level adoption of robotic prostatectomy. We used SEER (Surveillance, Epidemiology, and End Results)-Medicare data from 2003 through 2007 to identify men 66 years old or older treated with prostatectomy for prostate cancer. Using data from the American Health Planning Association, we categorized Health Service Areas according to the stringency of certificate of need regulations (ie low vs high stringency) presiding over that market. We assessed our outcomes (probability of adopting robotic prostatectomy and propensity for robotic prostatectomy use in adopting Health Service Areas) using Cox proportional hazards and Poisson regression models, respectively. Compared to low stringency markets, high stringency markets were more racially diverse (54% vs 15% nonwhite, p people per square mile, p = 0.97) and median incomes ($42,344 vs $39,770, p = 0.56). In general, both market types had an increase in the adoption and utilization of robotic prostatectomy. However, the probability of robotic prostatectomy adoption (p = 0.22) did not differ based on a market's certificate of need stringency and use was lower in high stringency markets (p markets, similar adoption rates suggest that other factors impact the diffusion of robotic prostatectomy. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    Science.gov (United States)

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  12. MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto [Oulu University Hospital, Department of Radiology, Oulu (Finland); Lakovaara, Martti [Oulu Deaconess Institute, Department of Surgery, Oulu (Finland); Hyvoenen, Pekka; Lehenkari, Petri [Oulu University Hospital, Department of Surgery, Oulu (Finland)

    2011-06-15

    The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)

  13. MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee

    International Nuclear Information System (INIS)

    Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto; Lakovaara, Martti; Hyvoenen, Pekka; Lehenkari, Petri

    2011-01-01

    The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)

  14. Prostate cancer: diagnostic value of dynamic contrast-enhanced MRI, diffusion weighted imaging and 3D 1H-MR spectroscopy

    International Nuclear Information System (INIS)

    Shi Hao; Wu Lebin; Ding Hongyu; Zhao Bin; Wang Tao; Yang Zhenzhen; Qiu Xiuling; Li Huihua; Qu Lei; Wu Yulong

    2006-01-01

    Objective: To explore the applying value of the diagnosis of dynamic contrast-enhanced MRI (DCE-MRI), diffusion weighted imaging (DWI) and 3D 1 H-MR spectroscopy (MRS) in prostate cancer (PC). Methods: Thirty-two cases with PC and 64 cases with benign prostatic hyperplasia (BPH) which were confirmed with biopsy-proven, operation and follow-up, and 29 healthy volunteers underwent the examinations of DCE-MRI, DWI and MRS. The signal intensity, ADC value, and Cho/Cit ratio and (Cho + Cr)/Cit ratio were measured respectively on the lesions of PC and BPH, normal prostatic peripheral zone (PZ) and normal prostatic central gland (CG) of DCE-MRI, DWI and MRS. The results were statistically treated with ANOVA. Results: The lesions showed obvious enhancement in the early phase of DCE-MRI and washed out in late phase in 18 of 22 cases with PC, who underwent the examination of DCE-MRI. The enhancement was obvious in early and strengthened gradually, and then went to decrease in late phase after peak value on the lesions in 38 of 40 cases with BPH. The signal intensities from different time and different lesions and tissues were treated statistically and the results showed that there were significant differences (P 0.05). The lesions were shown lower signal intensity on ADC map in 26 cases with PC, who were examined with DWI and the average ADC value was (104.23±26.15) x 10 -5 mm 2 /s. The average ADC Value of the lesions of 43 cases with BPH was (175.21±64.86) x 10 -5 mm 2 /s. The statistical analysis showed that there were significant differences between PC, BPH and CG except between PZ and BPH. Average Cho/Cit ratio and average (Cho + Cr)/Cit ratio of the lesions of PC were 2.26±0.91 and 2.85±1.01 respectively in 17 cases with PC, who were performed with MRS. The average Cho/Cit ratio and average (Cho + Cr)/Cit ratio were 0.46±0.23 and 0.57±0.20 respectively in 35 cases with BPH. After the statistical analyzing, the results presented that there were significant

  15. 3D conformal MRI-controlled transurethral ultrasound prostate therapy: validation of numerical simulations and demonstration in tissue-mimicking gel phantoms.

    Science.gov (United States)

    Burtnyk, Mathieu; N'Djin, William Apoutou; Kobelevskiy, Ilya; Bronskill, Michael; Chopra, Rajiv

    2010-11-21

    MRI-controlled transurethral ultrasound therapy uses a linear array of transducer elements and active temperature feedback to create volumes of thermal coagulation shaped to predefined prostate geometries in 3D. The specific aims of this work were to demonstrate the accuracy and repeatability of producing large volumes of thermal coagulation (>10 cc) that conform to 3D human prostate shapes in a tissue-mimicking gel phantom, and to evaluate quantitatively the accuracy with which numerical simulations predict these 3D heating volumes under carefully controlled conditions. Eleven conformal 3D experiments were performed in a tissue-mimicking phantom within a 1.5T MR imager to obtain non-invasive temperature measurements during heating. Temperature feedback was used to control the rotation rate and ultrasound power of transurethral devices with up to five 3.5 × 5 mm active transducer elements. Heating patterns shaped to human prostate geometries were generated using devices operating at 4.7 or 8.0 MHz with surface acoustic intensities of up to 10 W cm(-2). Simulations were informed by transducer surface velocity measurements acquired with a scanning laser vibrometer enabling improved calculations of the acoustic pressure distribution in a gel phantom. Temperature dynamics were determined according to a FDTD solution to Pennes' BHTE. The 3D heating patterns produced in vitro were shaped very accurately to the prostate target volumes, within the spatial resolution of the MRI thermometry images. The volume of the treatment difference falling outside ± 1 mm of the target boundary was, on average, 0.21 cc or 1.5% of the prostate volume. The numerical simulations predicted the extent and shape of the coagulation boundary produced in gel to within (mean ± stdev [min, max]): 0.5 ± 0.4 [-1.0, 2.1] and -0.05 ± 0.4 [-1.2, 1.4] mm for the treatments at 4.7 and 8.0 MHz, respectively. The temperatures across all MRI thermometry images were predicted within -0.3 ± 1.6 °C and 0

  16. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  17. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  18. Diffusion-weighted MRI of the prostate at 3.0 T: Comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI—The impact of SNR on ADC measurement

    International Nuclear Information System (INIS)

    Mazaheri, Yousef; Vargas, H. Alberto; Nyman, Gregory; Shukla-Dave, Amita; Akin, Oguz; Hricak, Hedvig

    2013-01-01

    Purpose: To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC + PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T. Methods: The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC + PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm 2 ) were acquired using both coil arrangements. On b = 0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed. Results: Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (P < 0.0001 for both). ADCs from DW-MR images obtained with all b-values in the PZ and TZ were significantly lower with PAC-MRI than with ERC-MRI (P < 0.001 for all). Conclusion: Lower SNR of DW-MR images of the prostate obtained with a PAC can significantly decrease ADC values at higher b-values compared to similar measurements obtained using the ERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution

  19. Molecular biomarkers to guide precision medicine in localized prostate cancer.

    Science.gov (United States)

    Smits, Minke; Mehra, Niven; Sedelaar, Michiel; Gerritsen, Winald; Schalken, Jack A

    2017-08-01

    Major advances through tumor profiling technologies, that include next-generation sequencing, epigenetic, proteomic and transcriptomic methods, have been made in primary prostate cancer, providing novel biomarkers that may guide precision medicine in the near future. Areas covered: The authors provided an overview of novel molecular biomarkers in tissue, blood and urine that may be used as clinical tools to assess prognosis, improve selection criteria for active surveillance programs, and detect disease relapse early in localized prostate cancer. Expert commentary: Active surveillance (AS) in localized prostate cancer is an accepted strategy in patients with very low-risk prostate cancer. Many more patients may benefit from watchful waiting, and include patients of higher clinical stage and grade, however selection criteria have to be optimized and early recognition of transformation from localized to lethal disease has to be improved by addition of molecular biomarkers. The role of non-invasive biomarkers is challenging the need for repeat biopsies, commonly performed at 1 and 4 years in men under AS programs.

  20. 3 Tesla multiparametric MRI for GTV-definition of Dominant Intraprostatic Lesions in patients with Prostate Cancer – an interobserver variability study

    International Nuclear Information System (INIS)

    Rischke, Hans Christian; Grosu, Anca L; Jilg, Cordula A; Nestle, Ursula; Fechter, Tobias; Doll, Christian; Volegova-Neher, Natalja; Henne, Karl; Scholber, Jutta; Knippen, Stefan; Kirste, Simon

    2013-01-01

    To evaluate the interobserver variability of gross tumor volume (GTV) - delineation of Dominant Intraprostatic Lesions (DIPL) in patients with prostate cancer using published MRI criteria for multiparametric MRI at 3 Tesla by 6 different observers. 90 GTV-datasets based on 15 multiparametric MRI sequences (T2w, diffusion weighted (DWI) and dynamic contrast enhanced (DCE)) of 5 patients with prostate cancer were generated for GTV-delineation of DIPL by 6 observers. The reference GTV-dataset was contoured by a radiologist with expertise in diagnostic imaging of prostate cancer using MRI. Subsequent GTV-delineation was performed by 5 radiation oncologists who received teaching of MRI-features of primary prostate cancer before starting contouring session. GTV-datasets were contoured using Oncentra Masterplan® and iplan® Net. For purposes of comparison GTV-datasets were imported to the Artiview® platform (Aquilab®), GTV-values and the similarity indices or Kappa indices (KI) were calculated with the postulation that a KI > 0.7 indicates excellent, a KI > 0.6 to < 0.7 substantial and KI > 0.5 to < 0.6 moderate agreement. Additionally all observers rated difficulties of contouring for each MRI-sequence using a 3 point rating scale (1 = easy to delineate, 2 = minor difficulties, 3 = major difficulties). GTV contouring using T2w (KI-T2w = 0.61) and DCE images (KI-DCE = 0.63) resulted in substantial agreement. GTV contouring using DWI images resulted in moderate agreement (KI-DWI = 0.51). KI-T2w and KI-DCE was significantly higher than KI-DWI (p = 0.01 and p = 0.003). Degree of difficulty in contouring GTV was significantly lower using T2w and DCE compared to DWI-sequences (both p < 0.0001). Analysis of delineation differences revealed inadequate comparison of functional (DWI, DCE) to anatomical sequences (T2w) and lack of awareness of non-specific imaging findings as a source of erroneous delineation. Using T2w and DCE sequences at 3 Tesla for GTV-definition of DIPL in

  1. Logistic regression model for diagnosis of transition zone prostate cancer on multi-parametric MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dikaios, Nikolaos; Halligan, Steve; Taylor, Stuart; Atkinson, David; Punwani, Shonit [University College London, Centre for Medical Imaging, London (United Kingdom); University College London Hospital, Departments of Radiology, London (United Kingdom); Alkalbani, Jokha; Sidhu, Harbir Singh; Fujiwara, Taiki [University College London, Centre for Medical Imaging, London (United Kingdom); Abd-Alazeez, Mohamed; Ahmed, Hashim; Emberton, Mark [University College London, Research Department of Urology, London (United Kingdom); Kirkham, Alex; Allen, Clare [University College London Hospital, Departments of Radiology, London (United Kingdom); Freeman, Alex [University College London Hospital, Department of Histopathology, London (United Kingdom)

    2014-09-17

    We aimed to develop logistic regression (LR) models for classifying prostate cancer within the transition zone on multi-parametric magnetic resonance imaging (mp-MRI). One hundred and fifty-five patients (training cohort, 70 patients; temporal validation cohort, 85 patients) underwent mp-MRI and transperineal-template-prostate-mapping (TPM) biopsy. Positive cores were classified by cancer definitions: (1) any-cancer; (2) definition-1 [≥Gleason 4 + 3 or ≥ 6 mm cancer core length (CCL)] [high risk significant]; and (3) definition-2 (≥Gleason 3 + 4 or ≥ 4 mm CCL) cancer [intermediate-high risk significant]. For each, logistic-regression mp-MRI models were derived from the training cohort and validated internally and with the temporal cohort. Sensitivity/specificity and the area under the receiver operating characteristic (ROC-AUC) curve were calculated. LR model performance was compared to radiologists' performance. Twenty-eight of 70 patients from the training cohort, and 25/85 patients from the temporal validation cohort had significant cancer on TPM. The ROC-AUC of the LR model for classification of cancer was 0.73/0.67 at internal/temporal validation. The radiologist A/B ROC-AUC was 0.65/0.74 (temporal cohort). For patients scored by radiologists as Prostate Imaging Reporting and Data System (Pi-RADS) score 3, sensitivity/specificity of radiologist A 'best guess' and LR model was 0.14/0.54 and 0.71/0.61, respectively; and radiologist B 'best guess' and LR model was 0.40/0.34 and 0.50/0.76, respectively. LR models can improve classification of Pi-RADS score 3 lesions similar to experienced radiologists. (orig.)

  2. Logistic regression model for diagnosis of transition zone prostate cancer on multi-parametric MRI

    International Nuclear Information System (INIS)

    Dikaios, Nikolaos; Halligan, Steve; Taylor, Stuart; Atkinson, David; Punwani, Shonit; Alkalbani, Jokha; Sidhu, Harbir Singh; Fujiwara, Taiki; Abd-Alazeez, Mohamed; Ahmed, Hashim; Emberton, Mark; Kirkham, Alex; Allen, Clare; Freeman, Alex

    2015-01-01

    We aimed to develop logistic regression (LR) models for classifying prostate cancer within the transition zone on multi-parametric magnetic resonance imaging (mp-MRI). One hundred and fifty-five patients (training cohort, 70 patients; temporal validation cohort, 85 patients) underwent mp-MRI and transperineal-template-prostate-mapping (TPM) biopsy. Positive cores were classified by cancer definitions: (1) any-cancer; (2) definition-1 [≥Gleason 4 + 3 or ≥ 6 mm cancer core length (CCL)] [high risk significant]; and (3) definition-2 (≥Gleason 3 + 4 or ≥ 4 mm CCL) cancer [intermediate-high risk significant]. For each, logistic-regression mp-MRI models were derived from the training cohort and validated internally and with the temporal cohort. Sensitivity/specificity and the area under the receiver operating characteristic (ROC-AUC) curve were calculated. LR model performance was compared to radiologists' performance. Twenty-eight of 70 patients from the training cohort, and 25/85 patients from the temporal validation cohort had significant cancer on TPM. The ROC-AUC of the LR model for classification of cancer was 0.73/0.67 at internal/temporal validation. The radiologist A/B ROC-AUC was 0.65/0.74 (temporal cohort). For patients scored by radiologists as Prostate Imaging Reporting and Data System (Pi-RADS) score 3, sensitivity/specificity of radiologist A 'best guess' and LR model was 0.14/0.54 and 0.71/0.61, respectively; and radiologist B 'best guess' and LR model was 0.40/0.34 and 0.50/0.76, respectively. LR models can improve classification of Pi-RADS score 3 lesions similar to experienced radiologists. (orig.)

  3. ESUR prostate MR guidelines 2012

    DEFF Research Database (Denmark)

    Barentsz, Jelle O; Richenberg, Jonathan; Clements, Richard

    2012-01-01

    The aim was to develop clinical guidelines for multi-parametric MRI of the prostate by a group of prostate MRI experts from the European Society of Urogenital Radiology (ESUR), based on literature evidence and consensus expert opinion. True evidence-based guidelines could not be formulated......, but a compromise, reflected by "minimal" and "optimal" requirements has been made. The scope of these ESUR guidelines is to promulgate high quality MRI in acquisition and evaluation with the correct indications for prostate cancer across the whole of Europe and eventually outside Europe. The guidelines...... provides guidelines for magnetic resonance imaging (MRI) in prostate cancer. Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described....

  4. The efficacy and utilisation of preoperative multiparametric magnetic resonance imaging in robot-assisted radical prostatectomy: does it change the surgical dissection plan?

    Science.gov (United States)

    Tavukçu, Hasan Hüseyin; Aytaç, Ömer; Balcı, Numan Cem; Kulaksızoğlu, Haluk; Atuğ, Fatih

    2017-12-01

    We investigated the effect of the use of multiparametric prostate magnetic resonance imaging (mp-MRI) on the dissection plan of the neurovascular bundle and the oncological results of our patients who underwent robot-assisted radical prostatectomy. We prospectively evaluated 60 consecutive patients, including 30 patients who had (Group 1), and 30 patients who had not (Group 2) mp-MRI before robot-assisted radical prostatectomy. Based on the findings of mp-MRI, the dissection plan was changed as intrafascial, interfascial, and extrafascial in the mp-MRI group. Two groups were compared in terms of age, prostate-specific antigen (PSA), Gleason sum scores and surgical margin positivity. There was no statistically significant difference between the two groups in terms of age, PSA, biopsy Gleason score, final pathological Gleason score and surgical margin positivity. mp-MRI changed the initial surgical plan in 18 of 30 patients (60%) in Group 1. In seventeen of these patients (56%) surgical plan was changed from non-nerve sparing to interfascial nerve sparing plan. In one patient dissection plan was changed to non-nerve sparing technique which had extraprostatic extension on final pathology. Surgical margin positivity was similar in Groups 1, and 2 (16% and 13%, respectively) although, Group 1 had higher number of high- risk patients. mp-MRI confirmed the primary tumour localisation in the final pathology in 27 of of 30 patients (90%). Preoperative mp-MRI effected the decision to perform a nerve-sparing technique in 56% of the patients in our study; moreover, changing the dissection plan from non-nerve-sparing technique to a nerve sparing technique did not increase the rate of surgical margin positivity.

  5. Development of a computer aided diagnosis model for prostate cancer classification on multi-parametric MRI

    Science.gov (United States)

    Alfano, R.; Soetemans, D.; Bauman, G. S.; Gibson, E.; Gaed, M.; Moussa, M.; Gomez, J. A.; Chin, J. L.; Pautler, S.; Ward, A. D.

    2018-02-01

    Multi-parametric MRI (mp-MRI) is becoming a standard in contemporary prostate cancer screening and diagnosis, and has shown to aid physicians in cancer detection. It offers many advantages over traditional systematic biopsy, which has shown to have very high clinical false-negative rates of up to 23% at all stages of the disease. However beneficial, mp-MRI is relatively complex to interpret and suffers from inter-observer variability in lesion localization and grading. Computer-aided diagnosis (CAD) systems have been developed as a solution as they have the power to perform deterministic quantitative image analysis. We measured the accuracy of such a system validated using accurately co-registered whole-mount digitized histology. We trained a logistic linear classifier (LOGLC), support vector machine (SVC), k-nearest neighbour (KNN) and random forest classifier (RFC) in a four part ROI based experiment against: 1) cancer vs. non-cancer, 2) high-grade (Gleason score ≥4+3) vs. low-grade cancer (Gleason score work will form the basis for a tool that enhances the radiologist's ability to detect malignancies, potentially improving biopsy guidance, treatment selection, and focal therapy for prostate cancer patients, maximizing the potential for cure and increasing quality of life.

  6. Magnetic resonance–guided interstitial high-intensity focused ultrasound for brain tumor ablation

    Science.gov (United States)

    MacDonell, Jacquelyn; Patel, Niravkumar; Rubino, Sebastian; Ghoshal, Goutam; Fischer, Gregory; Burdette, E. Clif; Hwang, Roy; Pilitsis, Julie G.

    2018-01-01

    Currently, treatment of brain tumors is limited to resection, chemotherapy, and radiotherapy. Thermal ablation has been recently explored. High-intensity focused ultrasound (HIFU) is being explored as an alternative. Specifically, the authors propose delivering HIFU internally to the tumor with an MRI-guided robotic assistant (MRgRA). The advantage of the authors’ interstitial device over external MRI-guided HIFU (MRgHIFU) is that it allows for conformal, precise ablation and concurrent tissue sampling. The authors describe their workflow for MRgRA HIFU delivery. PMID:29385926

  7. Detection of prostate cancer in peripheral zone: comparison of MR diffusion tensor imaging, quantitative dynamic contrast-enhanced MRI, and the two techniques combined at 3.0 T.

    Science.gov (United States)

    Li, Chunmei; Chen, Min; Li, Saying; Zhao, Xuna; Zhang, Chen; Luo, Xiaojie; Zhou, Cheng

    2014-03-01

    Previous studies have shown that the diagnostic accuracy for prostate cancer improved with diffusion tensor imaging (DTI) or quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) only. However, the efficacy of combined DTI and quantitative DCE-MRI in detecting prostate cancer at 3.0 T is still indeterminate. To investigate the utility of diffusion tensor imaging (DTI), quantitative DCE-MRI, and the two techniques combined at 3.0 T in detecting prostate cancer of the peripheral zone (PZ). DTI and DCE-MRI of 33 patients was acquired prior to prostate biopsy. Regions of interest (ROIs) were drawn according to biopsy zones which were apex, mid-gland, and base on each side of the PZ. Apparent diffusion coefficient (ADC), fractional anisotropy (FA), volume transfer constant (K(trans)), and rate constant (kep) values of cancerous sextants and non-cancerous sextants in PZ were calculated. Logistic regression models were generated for DTI, DCE-MRI, and DTI + DCE-MRI. Receiver-operating characteristic (ROC) curves were used to compare the ability of these models to differentiate cancerous sextants from non-cancerous sextants of PZ. There were significant differences in the ADC, FA, K(trans), and kep values between cancerous sextants and non-cancerous sextants in PZ (P < 0.0001, P < 0.0001, P < 0.0001, and P < 0.0001, respectively). The area under curve (AUC) for DTI + DCE-MRI was significantly greater than that for either DTI (0.93 vs. 0.86, P = 0.0017) or DCE-MRI (0.93 vs. 0.84, P = 0.0034) alone. The combination of DTI and quantitative DCE-MRI has better diagnostic performance in detecting prostate cancer of the PZ than either technique alone.

  8. Feasibility of a 2"n"d generation MR-compatible manipulator for transrectal prostate biopsy guidance

    International Nuclear Information System (INIS)

    Bomers, J.G.R.; Yakar, D.; Bosboom, D.G.H.; Tigelaar, G.H.; Sabisch, J.; Fuetterer, J.J.

    2017-01-01

    To assess the feasibility of a 2"n"d generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  9. Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm

    International Nuclear Information System (INIS)

    Siversson, Carl; Nordström, Fredrik; Nilsson, Terese; Nyholm, Tufve; Jonsson, Joakim; Gunnlaugsson, Adalsteinn; Olsson, Lars E.

    2015-01-01

    Purpose: In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. Methods: The study comprised ten prostate cancer patients, for whom a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). Results: The MAE within the body contour was 36.5 ± 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% ± 0.2% (1 s.d.) between sCT and rCT, whereas it was −0.3% ± 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. Conclusions: The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties

  10. Design of a MRI-compatible dielectric elastomer powered jet valve

    Science.gov (United States)

    Proulx, Sylvain; Chouinard, Patrick; Lucking Bigue, Jean-Philippe; Miron, Geneviève; Plante, Jean-Sébastien

    2011-04-01

    Binary Pneumatic Air Muscles (PAM) arranged in an elastically-averaged configuration can form a cost effective solution for Magnetic Resonance Imaging (MRI) guided robotic interventions like prostate cancer biopsies and brachytherapies. Such binary pneumatic manipulators require about 10 to 20 MRI-compatible valves to control the pressure state of each PAM. In this perspective, this paper presents the design of a novel dielectric elastomer actuator (DEA) driven jet-valve to control the states of the PAMs. DEAs are MRI compatible actuators that are well suited to the simplicity and cost-effectiveness of the binary manipulation approach. The key feature of the proposed valve design is its 2 stages configuration in which the pilot stage is moved with minimal mechanical friction by a rotary antagonistic DEA made with acrylic polymer films. The prismatic geometry also integrates the jet nozzle within the DEA volume to provide a compact embodiment with a reduced number of parts. The low actuation stretches enabled by the rotary configuration minimize viscoelastic losses, and thus, maximize the frequency response of the actuator while maximizing its reliability potential. The design space of the proposed jet valve is studied using an Ogden hyperelastic model and the valve dynamics is predicted with a 1D Bergstrom-Boyce viscoelastic model. Altogether, the low friction of the pilot stage and optimized DEA dynamics provide an experimental shifting time of the complete assembly in the 200-300ms range. Results from this work suggest that the DEA driven jet valve has great potential for switching a large number of pneumatic circuits in a MRI environment with a compact, low cost and simple embodiment.

  11. Evaluation of Tumor Viability for Primary and Bone Metastases in Metastatic Castration-Resistant Prostate Cancer Using Whole-Body Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Hiromichi Iwamura

    2018-01-01

    Full Text Available In contrast to bone scan and computed tomography (CT, which depend on osteoblastic response to detect bone metastasis, whole-body magnetic resonance imaging (WB-MRI may be able to directly detect viable tumors. A 75-year-old male who had progressive metastatic prostate cancer during primary androgen deprivation therapy was referred to our hospital. Although bone scan and CT showed multiple bone metastases, WB-MRI suggested nonviable bone metastasis and viable tumor of the primary lesion. Prostate needle biopsy demonstrated viable prostate cancer cells from 10 of 12 cores. In contrast, CT-guided needle biopsy from bone metastasis of the lumbar vertebra revealed no malignant cells. Based on these findings, we reasoned that viable tumor cells inducing disease progression may primarily exist in the primary lesions and not in the metastatic lesions, and combined prostate radiotherapy and systemic hormonal therapy resulted in successful clinical response and disease control. The use of WB-MRI to detect viable disease lesions may enable us to design optimal treatment strategies for patients with metastatic castration-resistant prostate cancer.

  12. Design and characterization of Stormram 4 : an MRI-compatible robotic system for breast biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Veltman, Jeroen; Stramigioli, Stefano

    2017-01-01

    Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able

  13. Prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, G.P.; Kuss, R., Khoury, S.; Chatelain, C.; Denis, L.

    1987-01-01

    This book contains over 70 selections. Some of the titles are: Place of the Computed Tomography in the Staging of Prostatic Cancer; Magnetic Resonance Imaging (MRI) in Staging of the Prostatic Cancer; Magnetic Resonance Imaging of the Prostate; Long-Term Results in Radiotherapy of Prostatic Cancer; Interstitial Irradiation Using I-125 Seeds; and Treatment of Cancer of the Prostate by Use of Physiotherapy: Long-Term Results.

  14. Prostate cancer

    International Nuclear Information System (INIS)

    Murphy, G.P.; Kuss, R.; Khoury, S.; Chatelain, C.; Denis, L.

    1987-01-01

    This book contains over 70 selections. Some of the titles are: Place of the Computed Tomography in the Staging of Prostatic Cancer; Magnetic Resonance Imaging (MRI) in Staging of the Prostatic Cancer; Magnetic Resonance Imaging of the Prostate; Long-Term Results in Radiotherapy of Prostatic Cancer; Interstitial Irradiation Using I-125 Seeds; and Treatment of Cancer of the Prostate by Use of Physiotherapy: Long-Term Results

  15. SU-F-J-161: Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Elzibak, A; Loblaw, A; Morton, G; Vesprini, D; Liu, S; Chung, H; Davidson, M [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: To investigate the usefulness of metal artifact reduction in CT images of patients with bilateral hip prostheses (BHP) for contouring the prostate and determine if the inclusion of MR images provides additional benefits. Methods: Five patients with BHP were CT scanned using our clinical protocol (140kV, 300mAs, 3mm slices, 1.5mm increment, Philips Medical Systems, OH). Images were reconstructed with the orthopaedic metal artifact reduction (O-MAR) algorithm. MRI scanning was then performed (1.5T, GE Healthcare, WI) with a flat table-top (T{sub 2}-weighted, inherent body coil, FRFSE, 3mm slices with 0mm gap). All images were transferred to Pinnacle (Version 9.2, Philips Medical Systems). For each patient, two data sets were produced: one containing the O-MAR-corrected CT images and another containing fused MRI and O-MAR-corrected CT images. Four genito-urinary radiation oncologists contoured the prostate of each patient on the O-MAR-corrected CT data. Two weeks later, they contoured the prostate on the fused data set, blinded to all other contours. During each contouring session, the oncologists reported their confidence in the contours (1=very confident, 3=not confident) and the contouring difficulty that they experienced (1=really easy, 4=very challenging). Prostate volumes were computed from the contours and the conformity index was used to evaluate inter-observer variability. Results: Larger prostate volumes were found on the O-MAR-corrected CT set than on the fused set (p< 0.05, median=36.9cm{sup 3} vs. 26.63 cm{sup 3}). No significant differences were noted in the inter-observer variability between the two data sets (p=0.3). Contouring difficulty decreased with the addition of MRI (p<0.05) while the radiation oncologists reported more confidence in their contours when MRI was fused with the O-MAR-corrected CT data (p<0.05). Conclusion: This preliminary work demonstrated that, while O-MAR correction to CT images improves visualization of anatomy, the

  16. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Korsager, Anne Sofie; Østergaard, Lasse Riis; Carl, Jesper

    2013-01-01

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  17. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Korsager, Anne Sofie; Ostergaard, Lasse Riis [Department of Health Science and Technology, Aalborg University, Aalborg 9220 (Denmark); Carl, Jesper [Department of Medical Physics, Oncology, Aalborg Hospital, Aalborg 9100 (Denmark)

    2013-06-15

    Purpose: In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent.Methods: The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration.Results: In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41 Degree-Sign {+-} 0.45 Degree-Sign and a translation error of 1.67 {+-} 2.24 mm.Conclusions: This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  18. Polygenic hazard score to guide screening for aggressive prostate cancer

    DEFF Research Database (Denmark)

    Seibert, Tyler M; Fan, Chun Chieh; Wang, Yunpeng

    2018-01-01

    . These polymorphisms were incorporated into a survival analysis to estimate their effects on age at diagnosis of aggressive PCa (that is, not eligible for surveillance according to National Comprehensive Cancer Network guidelines; any of Gleason score ≥7, stage T3-T4, PSA (prostate specific antigen) concentration ≥10......OBJECTIVES: To develop and validate a genetic tool to predict age of onset of aggressive prostate cancer (PCa) and to guide decisions of who to screen and at what age. DESIGN: Analysis of genotype, PCa status, and age to select single nucleotide polymorphisms (SNPs) associated with diagnosis...

  19. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  20. Converting from CT- to MRI-only-based target definition in radiotherapy of localized prostate cancer. A comparison between two modalities

    Energy Technology Data Exchange (ETDEWEB)

    Seppaelae, Tiina; Visapaeae, Harri; Collan, Juhani; Kapanen, Mika; Kouri, Mauri; Tenhunen, Mikko; Saarilahti, Kauko [University of Helsinki and Helsinki University Hospital, Comprehensive Cancer Center, POB 180, Helsinki (Finland); Beule, Annette [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 180, Helsinki (Finland)

    2015-11-15

    To investigate the conversion of prostate cancer radiotherapy (RT) target definition from CT-based planning into an MRI-only-based planning procedure. Using the CT- and MRI-only-based RT planning protocols, 30 prostate cancer patients were imaged in the RT fixation position. Two physicians delineated the prostate in both CT and T2-weighted MRI images. The CT and MRI images were coregistered based on gold seeds and anatomic borders of the prostate. The uncertainty of the coregistration, as well as differences in target volumes and uncertainty of contour delineation were investigated. Conversion of margins and dose constraints from CT- to MRI-only-based treatment planning was assessed. On average, the uncertainty of image coregistration was 0.4 ± 0.5 mm (one standard deviation, SD), 0.9 ± 0.8 mm and 0.9 ± 0.9 mm in the lateral, anterior-posterior and base-apex direction, respectively. The average ratio of the prostate volume between CT and MRI was 1.20 ± 0.15 (one SD). Compared to the CT-based contours, the MRI-based contours were on average 2-7 mm smaller in the apex, 0-1 mm smaller in the rectal direction and 1-4 mm smaller elsewhere. When converting from a CT-based planning procedure to an MRI-based one, the overall planning target volumes (PTV) are prominently reduced only in the apex. The prostate margins and dose constraints can be retained by this conversion. (orig.) [German] Ziel unserer Studie war es, die Umstellung der Strahlentherapieplanung des Prostatakarzinoms von CT-gestuetzter in ausschliesslich MR-gestuetzte Zieldefinition zu untersuchen. Bei 30 Patienten mit Prostatakarzinom wurden eine CT und eine MRT unter Planungsbedingungen durchgefuehrt. Zwei Untersucher konturierten die Prostata in CT- und T2-gewichteten MR-Bildern. Mit Hilfe der Position von Goldstiften und der anatomischen Grenzen der Prostata wurden die CT- und MR-Bilder koregistriert. Es wurden die Genauigkeit der Koregistrierung sowie die Unterschiede der Zielvolumina und der

  1. Feasibility of robotic radical prostatectomy for medication refractory chronic prostatitis/chronic pelvic pain syndrome: Initial results

    Directory of Open Access Journals (Sweden)

    Sameer Chopra

    2016-01-01

    Full Text Available Four patients diagnosed with chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS, met criteria for National Institute of Health (NIH Category III prostatitis, failed multiple medicinal treatments and underwent robotic radical prostatectomy (RRP. Median operative time (range: 157 (127–259 min. Validated functional questionnaires responses and NIH CP symptom index (NIH-CPSI score were collected for each patient's status at different time points pre- and post-operatively. Median decreases (range were: International Prostate Symptom Score - 14 (1–19; Sexual Health Inventory for Men - 6 (−14–22; and NIH-CPSI total - 23.5 (13–33. Median length of follow-up (range was 34 (24–43 months. RRP appears to be an option for carefully selected patients with medication-refractory CP/CPPS who understand that baseline sexual function may not be restored postoperatively.

  2. Advances in prostate-specific membrane antigen PET of prostate cancer.

    Science.gov (United States)

    Bouchelouche, Kirsten; Choyke, Peter L

    2018-05-01

    In recent years, a large number of reports have been published on prostate-specific membrane antigen (PSMA)/PET in prostate cancer (PCa). This review highlights advances in PSMA PET in PCa during the past year. PSMA PET/computed tomography (CT) is useful in detection of biochemical recurrence, especially at low prostate-specific antigen (PSA) values. The detection rate of PSMA PET is influenced by PSA level. For primary PCa, PSMA PET/CT shows promise for tumour localization in the prostate, especially in combination with multiparametric MRI (mpMRI). For primary staging, PSMA PET/CT can be used in intermediate and high-risk PCa. Intraoperative PSMA radioligand guidance seems promising for detection of malignant lymph nodes. While the use of PSMA PET/MRI in primary localized disease is limited to high and intermediate-risk patients and localized staging, in the recurrence setting, PET/MRI can be particularly helpful when the lesions are subtle. PSMA PET/CT is superior to choline PET/CT and other conventional imaging modalities. Molecular imaging with PSMA PET continues to pave the way for personalized medicine in PCa.However, large prospective clinical studies are still needed to fully evaluate the role of PSMA PET/CT and PET/MRI in the clinical workflow of PCa.

  3. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    Science.gov (United States)

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  4. Is there a role for anterior zone sampling as part of saturation trans-rectal ultrasound guided prostate biopsy?

    Science.gov (United States)

    Cole, Eric; Margel, David; Greenspan, Michael; Shayegan, Bobby; Matsumoto, Edward; Fischer, Marc A; Patlas, Michael; Daya, Dean; Pinthus, Jehonathan H

    2014-05-03

    The prostatic anterior zone (AZ) is not targeted routinely by TRUS guided prostate biopsy (TRUS-Pbx). MRI is an accurate diagnostic tool for AZ tumors, but is often unavailable due to cost or system restrictions. We examined the diagnostic yield of office based AZ TRUS-Pbx. 127 men at risk for AZ tumors were studied: Patients with elevated PSA and previous extended negative TRUS-Pbx (group 1, n = 78) and actively surveyed low risk prostate cancer patients (group 2, n = 49). None of the participants had a previous AZ biopsy. Biopsy template included suspicious ultrasonic areas, 16 peripheral zone (PZ), 4 transitional zone (TZ) and 6 AZ cores. All biopsies were performed by a single urologist under local peri-prostatic anaesthetic, using the B-K Medical US System, an end-firing probe 4-12 MHZ and 18 ga/25 cm needle. All samples were reviewed by a single specialized uro-pathologist. Multivariate analysis was used to detect predictors for AZ tumors accounting for age, PSA, PSA density, prostate volume, BMI, and number of previous biopsies. Median PSA was 10.4 (group 1) and 7.3 (group 2). Age (63.9, 64.5), number of previous biopsies (1.5) and cores (17.8, 21.3) and prostate volume (56.4 cc, 51 cc) were similar for both groups. The overall diagnostic yield was 34.6% (group 1) and 85.7% (group 2). AZ cancers were detected in 21.8% (group 1) and 34.7% (group 2) but were rarely the only zone involved (1.3% and 4.1% respectively). Gleason ≥ 7 AZ cancers were often accompanied by equal grade PZ tumors. In multivariate analysis only prostate volume predicted for AZ tumors. Patients detected with AZ tumors had significantly smaller prostates (36.9 cc vs. 61.1 cc p < 0.001). Suspicious AZ ultrasonic findings were uncommon (6.3%). TRUS-Pbx AZ sampling rarely improves the diagnostic yield of extended PZ sampling in patients with elevated PSA and previous negative biopsies. In low risk prostate cancer patients who are followed by active surveillance, AZ sampling changes risk

  5. The value of magnetic resonance imaging and ultrasonography (MRI/US)-fusion biopsy platforms in prostate cancer detection: a systematic review

    NARCIS (Netherlands)

    Gayet, M.; Aa, A. van der; Beerlage, H.P.; Schrier, B.P.; Mulders, P.F.A.; Wijkstra, H.

    2016-01-01

    Despite limitations considering the presence, staging and aggressiveness of prostate cancer, ultrasonography (US)-guided systematic biopsies (SBs) are still the 'gold standard' for the diagnosis of prostate cancer. Recently, promising results have been published for targeted prostate biopsies (TBs)

  6. Computer-aided diagnosis of prostate cancer using multi-parametric MRI: comparison between PUN and Tofts models

    Science.gov (United States)

    Mazzetti, S.; Giannini, V.; Russo, F.; Regge, D.

    2018-05-01

    Computer-aided diagnosis (CAD) systems are increasingly being used in clinical settings to report multi-parametric magnetic resonance imaging (mp-MRI) of the prostate. Usually, CAD systems automatically highlight cancer-suspicious regions to the radiologist, reducing reader variability and interpretation errors. Nevertheless, implementing this software requires the selection of which mp-MRI parameters can best discriminate between malignant and non-malignant regions. To exploit functional information, some parameters are derived from dynamic contrast-enhanced (DCE) acquisitions. In particular, much CAD software employs pharmacokinetic features, such as K trans and k ep, derived from the Tofts model, to estimate a likelihood map of malignancy. However, non-pharmacokinetic models can be also used to describe DCE-MRI curves, without any requirement for prior knowledge or measurement of the arterial input function, which could potentially lead to large errors in parameter estimation. In this work, we implemented an empirical function derived from the phenomenological universalities (PUN) class to fit DCE-MRI. The parameters of the PUN model are used in combination with T2-weighted and diffusion-weighted acquisitions to feed a support vector machine classifier to produce a voxel-wise malignancy likelihood map of the prostate. The results were all compared to those for a CAD system based on Tofts pharmacokinetic features to describe DCE-MRI curves, using different quality aspects of image segmentation, while also evaluating the number and size of false positive (FP) candidate regions. This study included 61 patients with 70 biopsy-proven prostate cancers (PCa). The metrics used to evaluate segmentation quality between the two CAD systems were not statistically different, although the PUN-based CAD reported a lower number of FP, with reduced size compared to the Tofts-based CAD. In conclusion, the CAD software based on PUN parameters is a feasible means with which to

  7. Improved operative efficiency using a real-time MRI-guided stereotactic platform for laser amygdalohippocampotomy.

    Science.gov (United States)

    Ho, Allen L; Sussman, Eric S; Pendharkar, Arjun V; Le, Scheherazade; Mantovani, Alessandra; Keebaugh, Alaine C; Drover, David R; Grant, Gerald A; Wintermark, Max; Halpern, Casey H

    2018-04-01

    OBJECTIVE MR-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive method for thermal destruction of benign or malignant tissue that has been used for selective amygdalohippocampal ablation for the treatment of temporal lobe epilepsy. The authors report their initial experience adopting a real-time MRI-guided stereotactic platform that allows for completion of the entire procedure in the MRI suite. METHODS Between October 2014 and May 2016, 17 patients with mesial temporal sclerosis were selected by a multidisciplinary epilepsy board to undergo a selective amygdalohippocampal ablation for temporal lobe epilepsy using MRgLITT. The first 9 patients underwent standard laser ablation in 2 phases (operating room [OR] and MRI suite), whereas the next 8 patients underwent laser ablation entirely in the MRI suite with the ClearPoint platform. A checklist specific to the real-time MRI-guided laser amydalohippocampal ablation was developed and used for each case. For both cohorts, clinical and operative information, including average case times and accuracy data, was collected and analyzed. RESULTS There was a learning curve associated with using this real-time MRI-guided system. However, operative times decreased in a linear fashion, as did total anesthesia time. In fact, the total mean patient procedure time was less in the MRI cohort (362.8 ± 86.6 minutes) than in the OR cohort (456.9 ± 80.7 minutes). The mean anesthesia time was significantly shorter in the MRI cohort (327.2 ± 79.9 minutes) than in the OR cohort (435.8 ± 78.4 minutes, p = 0.02). CONCLUSIONS The real-time MRI platform for MRgLITT can be adopted in an expedient manner. Completion of MRgLITT entirely in the MRI suite may lead to significant advantages in procedural times.

  8. Can pre-operative contrast-enhanced dynamic MR imaging for prostate cancer predict microvessel density in prostatectomy specimens?

    Energy Technology Data Exchange (ETDEWEB)

    Schlemmer, Heinz-Peter [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Department of Diagnostic Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076, Tuebingen (Germany); Merkle, Jonas; Kaick, Gerhard van [Department of Oncological Diagnostics and Therapy, German Cancer Research Center, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Grobholz, Rainer [Department of Pathology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Jaeger, Tim; Michel, Maurice Stephan [Department of Urology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany); Werner, Axel; Rabe, Jan [Department of Diagnostic Radiology, University Hospital Mannheim, Ruprecht Karls University, Heidelberg (Germany)

    2004-02-01

    The aim of this study was to correlate quantitative dynamic contrast-enhanced MRI (DCE MRI) parameters with microvessel density (MVD) in prostate carcinoma. Twenty-eight patients with biopsy-proven prostate carcinoma were examined by endorectal MRI including multiplanar T2- and T1-weighted spin-echo and dynamic T1-weighted turbo-FLASH MRI during and after intravenous Gd-DTPA administration. Microvessels were stained on surgical specimens using a CD31 monoclonal antibody. The MVD was quantified in hot spots by counting (MVC) and determining the area fraction by morphometry (MVAF). The DCE MRI data were analyzed using an open pharmacokinetic two-compartment model. In corresponding anatomic locations the time shift ({delta}t) between the beginning of signal enhancement of cancer and adjacent normal prostatic tissue, the degree of contrast enhancement and the contrast exchange rate constant (k{sub 21}) were calculated. The MVC and MVAF were elevated in carcinoma (p<0.001 and p=0.002, respectively) and correlated to k{sub 21} (r=0.62, p<0.001 and r=0.80, p<0.001, respectively). k{sub 21}-values of carcinoma were significantly higher compared with normal peripheral but not central zone tissue. {delta}t was longer in high compared with low-grade tumors (p=0.025). The DCE MRI can provide important information about individual MVD in prostate cancer, which may be helpful for guiding biopsy and assessing individual prognosis. (orig.)

  9. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    Science.gov (United States)

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  10. Paclitaxel-loaded iron platinum stealth immunomicelles are potent MRI imaging agents that prevent prostate cancer growth in a PSMA-dependent manner

    Directory of Open Access Journals (Sweden)

    Taylor RM

    2012-08-01

    Full Text Available Robert M Taylor,1,2 Laurel O Sillerud1,31Department of Biochemistry and Molecular Biology, 2New Mexico Cancer Nanoscience and Microsystems Training Center, 3UNM Cancer Center, University of New Mexico, Albuquerque, NM, USABackground and methods: Problems with the clinical management of prostate cancer include the lack of both specific detection and efficient therapeutic intervention. We report the encapsulation of superparamagnetic iron platinum nanoparticles (SIPPs and paclitaxel in a mixture of polyethyleneglycolated, fluorescent, and biotin-functionalized phospholipids to create multifunctional SIPP-PTX micelles (SPMs that were conjugated to an antibody against prostate-specific membrane antigen (PSMA for the specific targeting, magnetic resonance imaging (MRI, and treatment of human prostate cancer xenografts in mice.Results: SPMs were 45.4 ± 24.9 nm in diameter and composed of 160.7 ± 22.9 µg/mL iron, 247.0 ± 33.4 µg/mL platinum, and 702.6 ± 206.0 µg/mL paclitaxel. Drug release measurements showed that, at 37°C, half of the paclitaxel was released in 30.2 hours in serum and two times faster in saline. Binding assays suggested that PSMA-targeted SPMs specifically bound to C4-2 human prostate cancer cells in vitro and released paclitaxel into the cells. In vitro, paclitaxel was 2.2 and 1.6 times more cytotoxic than SPMs to C4-2 cells at 24 and 48 hours of incubation, respectively. After 72 hours of incubation, paclitaxel and SPMs were equally cytotoxic. SPMs had MRI transverse relaxivities of 389 ± 15.5 Hz/mM iron, and SIPP micelles with and without drug caused MRI contrast enhancement in vivo.Conclusion: Only PSMA-targeted SPMs and paclitaxel significantly prevented growth of C4-2 prostate cancer xenografts in nude mice. Furthermore, mice injected with PSMA-targeted SPMs showed significantly more paclitaxel and platinum in tumors, compared with nontargeted SPM-injected and paclitaxel-injected mice.Keywords: iron platinum, MRI

  11. Contextual analysis of human non-verbal guide behaviors to inform the development of FROG, the Fun Robotic Outdoor Guide

    NARCIS (Netherlands)

    Karreman, Daphne Eleonora; van Dijk, Elisabeth M.A.G.; Evers, Vanessa

    2012-01-01

    This paper reports the first step in a series of studies to design the interaction behaviors of an outdoor robotic guide. We describe and report the use case development carried out to identify effective human tour guide behaviors. In this paper we focus on non-verbal communication cues in gaze,

  12. 68Ga Bombesin PET/MRI in Patients with Biochemically Recurrent Prostate Cancer and Noncontributory Conventional Imaging

    Science.gov (United States)

    2017-10-01

    flight (TOF)-enabled simultaneous positron emission tomography (PET) / magnetic resonance imaging (MRI) scanner. T1-weighted (T1w), T2 -weighted (T2w...bombesin analog receptor antagonist (RM2) is used as a promising diagnostic method for patients with suspicion of PCa recurrence. Here, we evaluate ... evaluate if 68Ga-RM2 PET/MRI can improve the diagnostic accuracy of recurrent prostate cancer earlier, when PSA level is still low and no disease is seen

  13. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  14. Urinary morbidity following ultrasound-guided transperineal prostate seed implantation

    International Nuclear Information System (INIS)

    Gelblum, Daphna Y.; Potters, Louis; Ashley, Richard; Waldbaum, Robert; Wang Xiaohong; Leibel, Steven

    1999-01-01

    Purpose: To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Methods and Materials: Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125 I in 165 patients and with 103 Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125 I (pre TG43) or 120 Gy with 103 Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA ≥ 10 and/or Gleason score ≥ 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125 I or 103 Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of

  15. Outcomes of Interventional-MRI Versus Microelectrode Recording-Guided Subthalamic Deep Brain Stimulation

    Directory of Open Access Journals (Sweden)

    Philip S. Lee

    2018-04-01

    Full Text Available In deep brain stimulation (DBS of the subthalamic nucleus (STN for Parkinson’s disease (PD, there is debate concerning the use of neuroimaging alone to confirm correct anatomic placement of the DBS lead into the STN, versus the use of microelectrode recording (MER to confirm functional placement. We performed a retrospective study of a contemporaneous cohort of 45 consecutive patients who underwent either interventional-MRI (iMRI or MER-guided DBS lead implantation. We compared radial lead error, motor and sensory side effect, and clinical benefit programming thresholds, and pre- and post-operative unified PD rating scale scores, and levodopa equivalent dosages. MER-guided surgery was associated with greater radial error compared to the intended target. In general, side effect thresholds during initial programming were slightly lower in the MER group, but clinical benefit thresholds were similar. No significant difference in the reduction of clinical symptoms or medication dosage was observed. In summary, iMRI lead implantation occurred with greater anatomic accuracy, in locations demonstrated to be the appropriate functional region of the STN, based on the observation of similar programming side effect and benefit thresholds obtained with MER. The production of equivalent clinical outcomes suggests that surgeon and patient preference can be used to guide the decision of whether to recommend iMRI or MER-guided DBS lead implantation to appropriate patients with PD.

  16. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    International Nuclear Information System (INIS)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A.; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-01-01

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  17. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review

    Science.gov (United States)

    Iordachita, Iulian I.; Tokuda, Junichi; Hata, Nobuhiko; Liu, Xuan; Seifabadi, Reza; Xu, Sheng; Wood, Bradford; Fischer, Gregory S.

    2017-01-01

    Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures. PMID:28652857

  19. Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review.

    Science.gov (United States)

    Su, Hao; Iordachita, Iulian I; Tokuda, Junichi; Hata, Nobuhiko; Liu, Xuan; Seifabadi, Reza; Xu, Sheng; Wood, Bradford; Fischer, Gregory S

    2017-04-01

    Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures.

  20. Association between pathology and texture features of multi parametric MRI of the prostate

    Science.gov (United States)

    Kuess, Peter; Andrzejewski, Piotr; Nilsson, David; Georg, Petra; Knoth, Johannes; Susani, Martin; Trygg, Johan; Helbich, Thomas H.; Polanec, Stephan H.; Georg, Dietmar; Nyholm, Tufve

    2017-10-01

    The role of multi-parametric (mp)MRI in the diagnosis and treatment of prostate cancer has increased considerably. An alternative to visual inspection of mpMRI is the evaluation using histogram-based (first order statistics) parameters and textural features (second order statistics). The aims of the present work were to investigate the relationship between benign and malignant sub-volumes of the prostate and textures obtained from mpMR images. The performance of tumor prediction was investigated based on the combination of histogram-based and textural parameters. Subsequently, the relative importance of mpMR images was assessed and the benefit of additional imaging analyzed. Finally, sub-structures based on the PI-RADS classification were investigated as potential regions to automatically detect maligned lesions. Twenty-five patients who received mpMRI prior to radical prostatectomy were included in the study. The imaging protocol included T2, DWI, and DCE. Delineation of tumor regions was performed based on pathological information. First and second order statistics were derived from each structure and for all image modalities. The resulting data were processed with multivariate analysis, using PCA (principal component analysis) and OPLS-DA (orthogonal partial least squares discriminant analysis) for separation of malignant and healthy tissue. PCA showed a clear difference between tumor and healthy regions in the peripheral zone for all investigated images. The predictive ability of the OPLS-DA models increased for all image modalities when first and second order statistics were combined. The predictive value reached a plateau after adding ADC and T2, and did not increase further with the addition of other image information. The present study indicates a distinct difference in the signatures between malign and benign prostate tissue. This is an absolute prerequisite for automatic tumor segmentation, but only the first step in that direction. For the specific

  1. Multimodal 18F-Fluciclovine PET/MRI and Ultrasound-Guided Neurosurgery of an Anaplastic Oligodendroglioma.

    Science.gov (United States)

    Karlberg, Anna; Berntsen, Erik Magnus; Johansen, Håkon; Myrthue, Mariane; Skjulsvik, Anne Jarstein; Reinertsen, Ingerid; Esmaeili, Morteza; Dai, Hong Yan; Xiao, Yiming; Rivaz, Hassan; Borghammer, Per; Solheim, Ole; Eikenes, Live

    2017-12-01

    Structural magnetic resonance imaging (MRI) and histopathologic tissue sampling are routinely performed as part of the diagnostic workup for patients with glioma. Because of the heterogeneous nature of gliomas, there is a risk of undergrading caused by histopathologic sampling errors. MRI has limitations in identifying tumor grade and type, detecting diffuse invasive growth, and separating recurrences from treatment induced changes. Positron emission tomography (PET) can provide quantitative information of cellular activity and metabolism, and may therefore complement MRI. In this report, we present the first patient with brain glioma examined with simultaneous PET/MRI using the amino acid tracer 18 F-fluciclovine ( 18 F-FACBC) for intraoperative image-guided surgery. A previously healthy 60-year old woman was admitted to the emergency care with speech difficulties and a mild left-sided hemiparesis. MRI revealed a tumor that was suggestive of glioma. Before surgery, the patient underwent a simultaneous PET/MRI examination. Fused PET/MRI, T1, FLAIR, and intraoperative three-dimensional ultrasound images were used to guide histopathologic tissue sampling and surgical resection. Navigated, image-guided histopathologic samples were compared with PET/MRI image data to assess the additional value of the PET acquisition. Histopathologic analysis showed anaplastic oligodendroglioma in the most malignant parts of the tumor, while several regions were World Health Organization (WHO) grade II. 18 F-Fluciclovine uptake was found in parts of the tumor where regional WHO grade, cell proliferation, and cell densities were highest. This finding suggests that PET/MRI with this tracer could be used to improve accuracy in histopathologic tissue sampling and grading, and possibly for guiding treatments targeting the most malignant part of extensive and eloquent gliomas. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  2. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI ...

  3. The effect of androgen deprivation on the early changes in prostate volume following transperineal ultrasound guided interstitial therapy for localized carcinoma of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Whittington, Richard; Broderick, Gregory A; Arger, Peter; Malkowicz, S Bruce; Epperson, Robert D; Arjomandy, Bijan; Kassaee, Alireza

    1999-07-15

    Purpose: To determine the change in volume of the prostate as a result of neoadjuvant androgen deprivation prior to prostate implant and in the early postimplant period following transperineal ultrasound guided palladium-103 brachytherapy for early-stage prostate cancer. Methods and Materials: Sixty-nine men received 3 to 6 months of androgen deprivation therapy followed by treatment planning ultrasound followed 4 to 8 weeks later by palladium-103 implant of the prostate. All patients had clinical and radiographic stage T1c-T2b adenocarcinoma of the prostate. A second ultrasound study was carried out 11 to 13 days following the implant to determine the change in volume of the prostate as a result of the implant. The prehormonal and preimplant volumes were compared to the postimplant volume to determine the effect of hormones and brachytherapy on prostate volume. Results: The median decrease in prostate volume as a result of androgen deprivation was 33% among the 54 patients with prostate volume determinations prior to hormonal therapy. The reduction in volume was greatest in the quartile of men with the largest initial gland volume (59%) and least in the quartile of men with smallest glands (10%). The median reduction in prostate volume between the treatment planning ultrasound and the follow-up study after implant was 3%, but 23 (33%) patients had an increase in prostate volume, including 16 (23%) who had an increase in volume >20%; 11 of these patients (16%) had an increase in volume >30%. The time course of development and resolution of this edema is not known. The severity of the edema was not related to initial or preimplant prostate volume or duration of hormonal therapy. Conclusions: Prostate edema may significantly affect the dose delivered to the prostate following transperineal ultrasound guided brachytherapy. The effect on the actual delivered dose will be greater when shorter lived isotopes are used. It remains to be observed whether this edema will

  4. Multiparametric magnetic resonance imaging in the detection of prostate cancer

    International Nuclear Information System (INIS)

    Durmus, T.; Baur, A.; Hamm, B.

    2014-01-01

    Prostate cancer is the most common malignancy in men, but only about 10 % of patients die from that cancer. Recent studies suggest that not all patients benefit from a radical therapeutic approach. When prostate cancer is suspected, magnetic resonance imaging (MRI) can make an important contribution to cancer localization within the prostate. Many studies show that T2-weighted morphologic imaging should be supplemented by multiparametric MRI techniques including diffusion-weighted imaging, contrast-enhanced sequences, and MR spectroscopy. This approach detects aggressive prostate cancer with high sensitivity and specificity. The findings of multiparametric MRI additionally contribute information to the assessment of cancer aggressiveness. The use of these multiparametric MRI techniques will gain an increasing role in the clinical management of prostate cancer patients. They can help in establishing a definitive diagnosis with a minimum of invasiveness and may also contribute to optimal individualized treatment. This review article presents the different techniques of multiparametric MRI and discusses their contribution to the detection of prostate cancer. Moreover, this review outlines an objective approach to image interpretation and structured reporting of MRI findings using the PI-RADS criteria. The review concludes with an outline of approaches to prostate biopsy on the basis of MRI (transrectal ultrasound, direct MRI guidance of tissue sampling, and MRI-ultrasound fusion biopsy) and emerging future uses of MRI in the planning of focal treatment options and in the active surveillance of patients diagnosed with prostate cancer. (orig.)

  5. Rail-guided robotic end-effector position error due to rail compliance and ship motion

    NARCIS (Netherlands)

    Borgerink, Dian; Stegenga, J.; Brouwer, Dannis Michel; Woertche, H.J.; Stramigioli, Stefano

    2014-01-01

    A rail-guided robotic system is currently being designed for the inspection of ballast water tanks in ships. This robotic system will manipulate sensors toward the interior walls of the tank. In this paper, the influence of rail compliance on the end-effector position error due to ship movement is

  6. The safety issues of medical robotics

    Energy Technology Data Exchange (ETDEWEB)

    Fei Baowei; Ng, W.S.; Chauhan, Sunita; Kwoh, Chee Keong

    2001-08-01

    In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical resection of the prostate. Safety was always the key issue in the building of the robot. The HISIC strategies were adopted for safety enhancement in mechanical, electrical and software design. The initial test on URObot showed that HISIC had the potential ability to improve the safety of the system. Further safety experiments are being conducted in our laboratory.

  7. The safety issues of medical robotics

    International Nuclear Information System (INIS)

    Fei Baowei; Ng, W.S.; Chauhan, Sunita; Kwoh, Chee Keong

    2001-01-01

    In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, and electrical resection of the prostate. Safety was always the key issue in the building of the robot. The HISIC strategies were adopted for safety enhancement in mechanical, electrical and software design. The initial test on URObot showed that HISIC had the potential ability to improve the safety of the system. Further safety experiments are being conducted in our laboratory

  8. Feasibility of a 2{sup nd} generation MR-compatible manipulator for transrectal prostate biopsy guidance

    Energy Technology Data Exchange (ETDEWEB)

    Bomers, J.G.R.; Yakar, D. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Bosboom, D.G.H. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); Soteria Medical, Arnhem (Netherlands); Tigelaar, G.H.; Sabisch, J. [Soteria Medical, Arnhem (Netherlands); Fuetterer, J.J. [Radboud University Nijmegen Medical Center, Department of Radiology, route 766, P.O Box 9101, Nijmegen (Netherlands); University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-04-15

    To assess the feasibility of a 2{sup nd} generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with ≥1 cancer suspicious region (CSR) with a PI-RADS score of ≥3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. (orig.)

  9. Prostate cancer in magnetic resonance imaging: diagnostic utilites of spectroscopic sequences

    International Nuclear Information System (INIS)

    Caivano, Rocchina; Cirillo, Patrizia; Lotumolo, Antonella; Fortunato, Giovanna; Zandolino, Alexis; Cammarota, Aldo; Balestra, Antonio; Macarini, Luca; Vita, Giulia

    2012-01-01

    The aim of our work is to determine the efficacy of a combined study 3 Tesla Magnetic Resonance Imaging (3T MRI), with phased-array coil, for the detection of prostate cancer using magnetic resonance spectroscopy (MRS) and diffusion-weighted images (DWI) in identifying doubt nodules. In this study, we prospectively studied 46 patients who consecutively underwent digital-rectal exploration for high doses of prostate specific antigen (PSA), as well as a MRI examination and a subsequent rectal biopsy. The study of magnetic resonance imaging was performed with a Philips Achieva 3T scanner and phased-array coil. The images were obtained with turbo spin-echo sequences T2-weighted images, T1-weighted before and after the administration of contrast medium, DWI sequences and 3D spectroscopic sequences. The ultrasound-guided prostate biopsy was performed approximately 15 days after the MRI. The data obtained from MR images and spectroscopy were correlated with histological data. MRI revealed sensitivity and specificity of 88% and 61% respectively and positive predictive value (PPV) of 73%, negative predicted value (NPV) of 81% and accuracy of 76%. In identifying the location of prostate cancer, the sensitivity of 3T MRS was 92%, with a specificity of 89%, PPV of 87%, NPV of 88% and accuracy of 87%; DWI showed a sensitivity of 88%, specificity of 61%, PPV of 73%, NPV of 81% and accuracy of 76%. The 3T MR study with phased-array coil and the use of DWI and spectroscopic sequences, in addition to T2-weighted sequences, revealed to be accurate in the diagnosis of prostate cancer and in the identification of nodules to be biopsied. It may be indicated as a resolute way before biopsy in patients with elevated PSA value and can be proposed in the staging and follow-up.

  10. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    International Nuclear Information System (INIS)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K

    2016-01-01

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  11. TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D; Thomas, D; Cao, M; O’Connor, D; Lamb, J; Sheng, K [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA (United States)

    2016-06-15

    Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments

  12. T2-weighted prostate MRI at 7 Tesla using a simplified external transmit-receive coil array: correlation with radical prostatectomy findings in two prostate cancer patients.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Zhang, Bei; Ben-Eliezer, Noam; Le Nobin, Julien; Melamed, Jonathan; Deng, Fang-Ming; Taneja, Samir S; Wiggins, Graham C

    2015-01-01

    To report design of a simplified external transmit-receive coil array for 7 Tesla (T) prostate MRI, including demonstration of the array for tumor localization using T2-weighted imaging (T2WI) at 7T before prostatectomy. Following simulations of transmitter designs not requiring parallel transmission or radiofrequency-shimming, a coil array was constructed using loop elements, with anterior and posterior rows comprising one transmit-receive element and three receive-only elements. This coil structure was optimized using a whole-body phantom. In vivo sequence optimization was performed to optimize achieved flip angle (FA) and signal to noise ratio (SNR) in prostate. The system was evaluated in a healthy volunteer at 3T and 7T. The 7T T2WI was performed in two prostate cancer patients before prostatectomy, and localization of dominant tumors was subjectively compared with histopathological findings. Image quality was compared between 3T and 7T in these patients. Simulations of the B1(+) field in prostate using two-loop design showed good magnitude (B1(+) of 0.245 A/m/w(1/2)) and uniformity (nonuniformity [SD/mean] of 10.4%). In the volunteer, 90° FA was achieved in prostate using 225 v 1 ms hard-pulse (indicating good efficiency), FA maps confirmed good uniformity (14.1% nonuniformity), and SNR maps showed SNR gain of 2.1 at 7T versus 3T. In patients, 7T T2WI showed excellent visual correspondence with prostatectomy findings. 7T images demonstrated higher estimated SNR (eSNR) in benign peripheral zone (PZ) and tumor compared with 3T, but lower eSNR in fat and slight decreases in tumor-to-PZ contrast and PZ-homogeneity. We have demonstrated feasibility of a simplified external coil array for high-resolution T2-weighted prostate MRI at 7T. © 2013 Wiley Periodicals, Inc.

  13. [Robot-Assisted Laparoscopic Radical Prostatectomy for Patients with Prostatic Cancer and Factors Promoting Installation of the Robotic Surgical Equipment-Questionnaire Survey].

    Science.gov (United States)

    Tsukamoto, Taiji; Tanaka, Shigeru

    2015-08-01

    We conducted a questionnaire survey of hospitals with robot-assisted surgical equipment to study changes of the surgical case loads after its installation and the managerial strategies for its purchase. The study included 154 hospitals (as of April 2014) that were queried about their radical prostatectomy case loads from January 2009 to December 2013, strategies for installation of the equipment in their hospitals, and other topics related to the study purpose. The overall response rate of hospitals was 63%, though it marginally varied according to type and area. The annual case load was determined based on the results of the questionnaire and other modalities. It increased from 3,518 in 2009 to 6,425 in 2013. The case load seemed to be concentrated in hospitals with robot equipment since the increase of their number was very minimal over the 5 years. The hospitals with the robot treated a larger number of newly diagnosed patients with the disease than before. Most of the patients were those having localized cancer that was indicated for radical surgery, suggesting again the concentration of the surgical case loads in the hospitals with robots. While most hospitals believed that installation of a robot was necessary as an option for treatment procedures, the future strategy of the hospital, and other reasons, the action of the hospital to gain prestige may be involved in the process of purchasing the equipment. In conclusion, robot-assisted laparoscopic radical prostatectomy has become popular as a surgical procedure for prostate cancer in our society. This may lead to a concentration of the surgical case load in a limited number of hospitals with robots. We also discuss the typical action of an acute-care hospital when it purchases expensive clinical medical equipment.

  14. Prostate imaging. An update

    International Nuclear Information System (INIS)

    Franiel, T.; Teichgraeber, U.; Asbach, P.; Hamm, B.; Foller, S.

    2015-01-01

    New technical and clinical developments of sonography and magnetic resonance imaging include improved detection, localization and staging as well as active surveillance of prostate cancer. Multiparametric MRI can best answer these typical clinical questions. However, ultrasound elastography seems to be suitable for the detection of significant prostate cancer as well. The structured reporting system for multiparametric MRI of the prostate according to PI-RADS Version 1 led to improved and reproducible diagnosis of prostate cancer. The new PI-RADS Version 2 aims to minimize the limitations of Version 1 and make PI-RADS standardization more globally acceptable.

  15. Localization of the prostatic apex for radiation treatment planning

    International Nuclear Information System (INIS)

    Algan, Oezer; Hanks, Gerald E.; Shaer, Andrew H.

    1995-01-01

    Purpose: To determine whether retrograde urethrogram, or the combination of computed tomography (CT) scan/retrograde urethrogram is more accurate for locating the magnetic resonance imaging (MRI) designated prostatic apex, and to determine whether patients treated in our department with CT/urethrogram are receiving the prescribed minimal dose to the MRI identified prostatic apex. Methods and Materials: Seventeen patients with early stage prostate cancer were enrolled in a prospective study to determine the location of the prostatic apex. All of the patients agreed to undergo MRI in addition to retrograde urethrogram, and CT of the pelvis for three dimensional (3D) treatment planning. The prostatic apex was identified on each of the studies and measured from a reference point (the most superior portion of the pubic symphysis). The location of the prostatic apex as measured by retrograde urethrogram alone and by CT/urethrogram was compared to the location of the prostatic apex as measured by MRI. Because of MRI's ability for multiplanar capabilities, and high soft tissue contrast in the region of the prostate, it was assumed to be more accurate for identifying the location of the prostatic apex, and was used as the gold standard. Results: The location of the prostatic apex as determined by the urethrogram alone was on average 5.8 mm caudad to the location on MRI (p = 0.012), while the location of the prostatic apex as determined by CT/urethrogram was 3.1 mm caudad to the location on MRI (p = 0.150). If the prostatic apex is defined at 12 mm instead of 10 mm above the urethrogram tip, the statistically significant difference between the urethrogram and the MRI is no longer present. Based on these results, all 17 patients received the minimum prescribed dose to the prostatic apex. Conclusion: CT/urethrogram correlates better with the location of the MRI determined prostatic apex, than does the urethrogram alone. Locating the prostatic apex 12 mm above the urethrogram

  16. Functional anatomy of the prostate: Implications for treatment planning

    International Nuclear Information System (INIS)

    McLaughlin, Patrick W.; Troyer, Sara; Berri, Sally; Narayana, Vrinda; Meirowitz, Amichay; Roberson, Peter L.; Montie, James

    2005-01-01

    Purpose: To summarize the functional anatomy relevant to prostate cancer treatment planning. Methods and Materials: Coronal, axial, and sagittal T2 magnetic resonance imaging (MRI) and MRI angiography were fused by mutual information and registered with computed tomography (CT) scan data sets to improve definition of zonal anatomy of the prostate and critical adjacent structures. Results: The three major prostate zones (inner, outer, and anterior fibromuscular) are visible by T2 MRI imaging. The bladder, bladder neck, and internal (preprostatic) sphincter are a continuous muscular structure and clear definition of the preprostatic sphincter is difficult by MRI. Transition zone hypertrophy may efface the bladder neck and internal sphincter. The external 'lower' sphincter is clearly visible by T2 MRI with wide variations in length. The critical erectile structures are the internal pudendal artery (defined by MRI angiogram or T2 MRI), corpus cavernosum, and neurovascular bundle. The neurovascular bundle is visible along the posterior lateral surface of the prostate on CT and MRI, but its terminal branches (cavernosal nerves) are not visible and must be defined by their relationship to the urethra within the genitourinary diaphragm. Visualization of the ejaculatory ducts within the prostate is possible on sagittal MRI. The anatomy of the prostate-rectum interface is clarified by MRI, as is the potentially important distinction of rectal muscle and rectal mucosa. Conclusion: Improved understanding of functional anatomy and imaging of the prostate and critical adjacent structures will improve prostate radiation therapy by improvement of dose and toxicity correlation, limitation of dose to critical structures, and potential improvement in post therapy quality of life

  17. Long term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, P; Rasmussen, F; Holm, H H [Depts. of Urology and Ultrasound, Herlev Hospital, Univ. of Copenhagen (Denmark)

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months. Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is bigger than 0.5 ng/ml in 8 of these. The future role of ultrasonically guided implantation in the management of prostatic cancer is discussed. (au).

  18. Future of medical physics: Real-time MRI-guided proton therapy.

    Science.gov (United States)

    Oborn, Bradley M; Dowdell, Stephen; Metcalfe, Peter E; Crozier, Stuart; Mohan, Radhe; Keall, Paul J

    2017-08-01

    With the recent clinical implementation of real-time MRI-guided x-ray beam therapy (MRXT), attention is turning to the concept of combining real-time MRI guidance with proton beam therapy; MRI-guided proton beam therapy (MRPT). MRI guidance for proton beam therapy is expected to offer a compelling improvement to the current treatment workflow which is warranted arguably more than for x-ray beam therapy. This argument is born out of the fact that proton therapy toxicity outcomes are similar to that of the most advanced IMRT treatments, despite being a fundamentally superior particle for cancer treatment. In this Future of Medical Physics article, we describe the various software and hardware aspects of potential MRPT systems and the corresponding treatment workflow. Significant software developments, particularly focused around adaptive MRI-based planning will be required. The magnetic interaction between the MRI and the proton beamline components will be a key area of focus. For example, the modeling and potential redesign of a magnetically compatible gantry to allow for beam delivery from multiple angles towards a patient located within the bore of an MRI scanner. Further to this, the accuracy of pencil beam scanning and beam monitoring in the presence of an MRI fringe field will require modeling, testing, and potential further development to ensure that the highly targeted radiotherapy is maintained. Looking forward we envisage a clear and accelerated path for hardware development, leveraging from lessons learnt from MRXT development. Within few years, simple prototype systems will likely exist, and in a decade, we could envisage coupled systems with integrated gantries. Such milestones will be key in the development of a more efficient, more accurate, and more successful form of proton beam therapy for many common cancer sites. © 2017 American Association of Physicists in Medicine.

  19. Quantifying Post- Laser Ablation Prostate Therapy Changes on MRI via a Domain-Specific Biomechanical Model: Preliminary Findings.

    Directory of Open Access Journals (Sweden)

    Robert Toth

    Full Text Available Focal laser ablation destroys cancerous cells via thermal destruction of tissue by a laser. Heat is absorbed, causing thermal necrosis of the target region. It combines the aggressive benefits of radiation treatment (destroying cancer cells without the harmful side effects (due to its precise localization. MRI is typically used pre-treatment to determine the targeted area, and post-treatment to determine efficacy by detecting necrotic tissue, or tumor recurrence. However, no system exists to quantitatively evaluate the post-treatment effects on the morphology and structure via MRI. To quantify these changes, the pre- and post-treatment MR images must first be spatially aligned. The goal is to quantify (a laser-induced shape-based changes, and (b changes in MRI parameters post-treatment. The shape-based changes may be correlated with treatment efficacy, and the quantitative effects of laser treatment over time is currently poorly understood. This work attempts to model changes in gland morphology following laser treatment due to (1 patient alignment, (2 changes due to surrounding organs such as the bladder and rectum, and (3 changes due to the treatment itself. To isolate the treatment-induced shape-based changes, the changes from (1 and (2 are first modeled and removed using a finite element model (FEM. A FEM models the physical properties of tissue. The use of a physical biomechanical model is important since a stated goal of this work is to determine the physical shape-based changes to the prostate from the treatment, and therefore only physical real deformations are to be allowed. A second FEM is then used to isolate the physical, shape-based, treatment-induced changes. We applied and evaluated our model in capturing the laser induced changes to the prostate morphology on eight patients with 3.0 Tesla, T2-weighted MRI, acquired approximately six months following treatment. Our results suggest the laser treatment causes a decrease in prostate

  20. Why and Where do We Miss Significant Prostate Cancer with Multi-parametric Magnetic Resonance Imaging followed by Magnetic Resonance-guided and Transrectal Ultrasound-guided Biopsy in Biopsy-naïve Men?

    Science.gov (United States)

    Schouten, Martijn G; van der Leest, Marloes; Pokorny, Morgan; Hoogenboom, Martijn; Barentsz, Jelle O; Thompson, Les C; Fütterer, Jurgen J

    2017-06-01

    Knowledge of significant prostate (sPCa) locations being missed with magnetic resonance (MR)- and transrectal ultrasound (TRUS)-guided biopsy (Bx) may help to improve these techniques. To identify the location of sPCa lesions being missed with MR- and TRUS-Bx. In a referral center, 223 consecutive Bx-naive men with elevated prostate specific antigen level and/or abnormal digital rectal examination were included. Histopathologically-proven cancer locations, Gleason score, and tumor length were determined. All patients underwent multi-parametric MRI and 12-core systematic TRUS-Bx. MR-Bx was performed in all patients with suspicion of PCa on multi-parametric MRI (n=142). Cancer locations were compared between MR- and TRUS-Bx. Proportions were expressed as percentages, and the corresponding 95% confidence intervals were calculated. In total, 191 lesions were found in 108 patients with sPCa. From these lesion 74% (141/191) were defined as sPCa on either MR- or TRUS-Bx. MR-Bx detected 74% (105/141) of these lesions and 61% (86/141) with TRUS-Bx. TRUS-Bx detected more lesions compared with MR-Bx (140 vs 109). However, these lesions were often low risk (39%). Significant lesions missed with MR-Bx most often had involvement of dorsolateral (58%) and apical (37%) segments and missed segments with TRUS-Bx were located anteriorly (79%), anterior midprostate (50%), and anterior apex (23%). Both techniques have difficulties in detecting apical lesions. MR-Bx most often missed cancer with involvement of the dorsolateral part (58%) and TRUS-Bx with involvement of the anterior part (79%). Both biopsy techniques miss cancer in specific locations within the prostate. Identification of these lesions may help to improve these techniques. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  1. Local recurrence of prostate cancer after radical prostatectomy is at risk to be missed in {sup 68}Ga-PSMA-11-PET of PET/CT and PET/MRI: comparison with mpMRI integrated in simultaneous PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Martin T. [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg (Germany); Radtke, Jan P. [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Afshar-Oromieh, Ali; Flechsig, Paul; Giesel, Frederik; Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Roethke, Matthias C.; Bonekamp, David; Schlemmer, Heinz-Peter [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Hadaschik, Boris A.; Hohenfellner, Markus [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Gleave, Martin [University of British Columbia, The Vancouver Prostate Centre, Vancouver (Canada); Kopka, Klaus; Eder, Matthias [Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg (Germany); Heusser, Thorsten; Kachelriess, Marc [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Wieczorek, Kathrin [University Hospital Heidelberg, Institute of Pathology, Heidelberg (Germany); Sachpekidis, Christos; Dimitrakopoulou-Strauss, A. [Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg (Germany)

    2017-05-15

    The positron emission tomography (PET) tracer {sup 68}Ga-PSMA-11, targeting the prostate-specific membrane antigen (PSMA), is rapidly excreted into the urinary tract. This leads to significant radioactivity in the bladder, which may limit the PET-detection of local recurrence (LR) of prostate cancer (PC) after radical prostatectomy (RP), developing in close proximity to the bladder. Here, we analyze if there is additional value of multi-parametric magnetic resonance imaging (mpMRI) compared to the {sup 68}Ga-PSMA-11-PET-component of PET/CT or PET/MRI to detect LR. One hundred and nineteen patients with biochemical recurrence after prior RP underwent both hybrid {sup 68}Ga-PSMA-11-PET/CT{sub low-dose} (1 h p.i.) and -PET/MRI (2-3 h p.i.) including a mpMRI protocol of the prostatic bed. The comparison of both methods was restricted to the abdomen with focus on LR (McNemar). Bladder-LR distance and recurrence size were measured in axial T2w-TSE. A logistic regression was performed to determine the influence of these variables on detectability in {sup 68}Ga-PSMA-11-PET. Standardized-uptake-value (SUV{sub mean}) quantification of LR was performed. There were 93/119 patients that had at least one pathologic finding. In addition, 18/119 Patients (15.1%) were diagnosed with a LR in mpMRI of PET/MRI but only nine were PET-positive in PET/CT and PET/MRI. This mismatch was statistically significant (p = 0.004). Detection of LR using the PET-component was significantly influenced by proximity to the bladder (p = 0.028). The PET-pattern of LR-uptake was classified into three types (1): separated from bladder; (2): fuses with bladder, and (3): obliterated by bladder. The size of LRs did not affect PET-detectability (p = 0.84), mean size was 1.7 ± 0.69 cm long axis, 1.2 ± 0.46 cm short-axis. SUV{sub mean} in nine men was 8.7 ± 3.7 (PET/CT) and 7.0 ± 4.2 (PET/MRI) but could not be quantified in the remaining nine cases (obliterated by bladder). The present study demonstrates

  2. Imaging and prostate cancer

    International Nuclear Information System (INIS)

    Schwartz, Lawrence H.

    1996-01-01

    prostate gland. Only recently have advances in dynamic contrast enhanced CT scanning demonstrated differences in the internal zonal architecture of the prostate gland. The sensitivity of staging of local spread of prostate cancer is variable ranging from 18% to 75%. Magnetic resonance imaging of the prostate gland is a relatively new technique for staging prostate cancer. There is excellent tissue contrast between prostate cancers in the peripheral zone and normal prostate tissue. Initial evaluation of MRI for staging prostate cancer was disappointing due to poor accuracy of MRI for evaluation of small structures such as the neurovascular bundles, using the body coil. Subsequently specialized receiver (surface) coils have been designed to allow high resolution imaging of the prostate and to assess for extracapsular extension of tumor. These coils may be placed within the rectum or wrapped around the anterior and posterior pelvic walls. Images obtained with the endorectal or phased array coils are of better quality as measured by signal-to-noise and improved resolution. Improved accuracy of 16% has been demonstrated with the endorectal coil. The overall accuracy of staging prostate cancers has been reported between 69% and 89%. In order to evaluate the prostate, T1 and T2-weighted images of the prostate gland are obtained. T1-weighted images are most useful for visualizing the neurovascular bundles. Extension of tumor into the neurovascular bundle is evident when there is obliteration of high signal intensity fat between the prostate and the neurovascular bundle. Zonal architecture and the presence of prostate cancer is assessed on the T2-weighted images. Prostate cancer generally appears as areas of low signal intensity on the T2-weighted images. The seminal vesicles are of intermediate signal on T1-weighted images and are high signal on T2-weighted images appearing as tubular structures. When prostate cancer invades the seminal vesicles the normal high signal of T2

  3. What happens when a robot favors someone? How a tour guide robot uses gaze behavior to address multiple persons while storytelling about art

    NARCIS (Netherlands)

    Karreman, Daphne Eleonora; Sépulveda Bradford, Gilberto; van Dijk, Elisabeth M.A.G.; Lohse, M.; Evers, Vanessa

    2013-01-01

    We report intermediate results of an ongoing study into the effectiveness of robot gaze behaviors when addressing multiple persons. The work is being carried out as part of the EU FP7 project FROG and concerns the design and evaluation of interactive behaviors of a tour guide robot. Our objective is

  4. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  5. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D

    2014-07-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm(3) or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using

  6. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    International Nuclear Information System (INIS)

    Martin, Peter R.; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm 3 or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was

  7. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  8. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application.

    Science.gov (United States)

    Barkhausen, Jörg; Kahn, Thomas; Krombach, Gabriele A; Kuhl, Christiane K; Lotz, Joachim; Maintz, David; Ricke, Jens; Schönberg, Stefan O; Vogl, Thomas J; Wacker, Frank K

    2017-07-01

    Background  MRI is attractive for the guiding and monitoring of interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure physiologic parameters like flow and cardiac function. Method  The current status of interventional MRI for the clinical routine was analyzed. Results  The effort needed for the development of MR-safe monitoring systems and instruments initially resulted in the application of interventional MRI only for procedures that could not be performed by other means. Accordingly, biopsy of lesions in the breast, which are not detectable by other modalities, has been performed under MRI guidance for decades. Currently, biopsies of the prostate under MRI guidance are established in a similar fashion. At many sites blind biopsy has already been replaced by MR-guided biopsy or at least by the fusion of MR images with ultrasound. Cardiovascular interventions are performed at several centers for ablation as a treatment for atrial fibrillation. Conclusion  Interventional MRI has been established in the clinical routine for a variety of indications. Broader application can be expected in the clinical routine in the future owing to the multiple advantages compared to other techniques. Key points   · Due to the significant technical effort, MR-guided interventions are only recommended in the long term for regions in which MRI either facilitates or greatly improves the intervention.. · Breast biopsy of otherwise undetectable target lesions has long been established in the clinical routine. Prostate biopsy is currently being introduced in the clinical routine for similar reasons. Other methods such as MR-guided focused ultrasound for the treatment of uterine fibroids or tumor ablation of metastases represent alternative methods and are offered in many places.. · Endovascular MR-guided interventions offer advantages for a number of indications and have already been clinically established for the treatment of

  9. A reliability study on brain activation during active and passive arm movements supported by an MRI-compatible robot.

    Science.gov (United States)

    Estévez, Natalia; Yu, Ningbo; Brügger, Mike; Villiger, Michael; Hepp-Reymond, Marie-Claude; Riener, Robert; Kollias, Spyros

    2014-11-01

    In neurorehabilitation, longitudinal assessment of arm movement related brain function in patients with motor disability is challenging due to variability in task performance. MRI-compatible robots monitor and control task performance, yielding more reliable evaluation of brain function over time. The main goals of the present study were first to define the brain network activated while performing active and passive elbow movements with an MRI-compatible arm robot (MaRIA) in healthy subjects, and second to test the reproducibility of this activation over time. For the fMRI analysis two models were compared. In model 1 movement onset and duration were included, whereas in model 2 force and range of motion were added to the analysis. Reliability of brain activation was tested with several statistical approaches applied on individual and group activation maps and on summary statistics. The activated network included mainly the primary motor cortex, primary and secondary somatosensory cortex, superior and inferior parietal cortex, medial and lateral premotor regions, and subcortical structures. Reliability analyses revealed robust activation for active movements with both fMRI models and all the statistical methods used. Imposed passive movements also elicited mainly robust brain activation for individual and group activation maps, and reliability was improved by including additional force and range of motion using model 2. These findings demonstrate that the use of robotic devices, such as MaRIA, can be useful to reliably assess arm movement related brain activation in longitudinal studies and may contribute in studies evaluating therapies and brain plasticity following injury in the nervous system.

  10. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  11. [Image guided and robotic treatment--the advance of cybernetics in clinical medicine].

    Science.gov (United States)

    Fosse, E; Elle, O J; Samset, E; Johansen, M; Røtnes, J S; Tønnessen, T I; Edwin, B

    2000-01-10

    The introduction of advanced technology in hospitals has changed the treatment practice towards more image guided and minimal invasive procedures. Modern computer and communication technology opens up for robot aided and pre-programmed intervention. Several robotic systems are in clinical use today both in microsurgery and in major cardiac and orthopedic operations. As this trend develops, professions which are new in this context such as physicists, mathematicians and cybernetic engineers will be increasingly important in the treatment of patients.

  12. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S

    2017-08-01

    This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

  13. MRI-derived Restriction Spectrum Imaging Cellularity Index is Associated with High Grade Prostate Cancer on Radical Prostatectomy Specimens

    Directory of Open Access Journals (Sweden)

    Michael Andre Liss

    2015-02-01

    Full Text Available Objectives: We evaluate a novel magnetic resonance imaging (MRI technique to improve detection of aggressive prostate cancer. Methods: We performed a retrospective analysis of presurgical prostate MRI scans using an advanced diffusion weighted imaging technique called Restriction Spectrum Imaging (RSI, which can be presented as a normalized z-score statistic (RSI z-score. Scans were acquired prior to radical prostatectomy. Prostatectomy specimens were processed using whole mount sectioning and regions of interest (ROIs were drawn around individual prostate cancer (PCa tumors. Corresponding ROIs were drawn on the MRI imaging and paired with ROIs in regions with no pathology. RSI z-score and conventional apparent diffusion coefficient (ADC values were recorded for each ROI. Paired t-test, ANOVA and logistic regression analyses were performed.Results: We evaluated 28 patients with 64 regions of interest (28 benign and 36 PCa. The mean difference in RSI z-score (PCa ROI – Benign ROI was 2.17 (SE = 0.11; p <0.001 and in ADC was 551 mm2/sec (SE = 80 mm2/sec; paired t-test, p <0.001. The differences in the means among all groups (benign, primary Gleason 3 and primary Gleason 4 was significant for both RSI z-score (F3,64 = 97.7, p <0.001 and ADC (F3,64 = 13.9, p <0.001. A t-test was performed on only PCa tumor ROIs (n=36 to determine prostate cancer aggressiveness (Gleason 3 vs. Gleason 4 revealing that RSI z-score was still significant (p = 0.03, whereas, ADC values were no longer significant (p = 0.08. In multivariable analysis adjusting for age and race, RSI z-score was associated with PCa aggressiveness (OR 10.3, 95%CI: 1.4-78.0, p=0.02 while ADC trended to significance (p=0.07. Conclusions: The RSI derived normalized cellularity index (RSI z-score is associated with aggressive prostate cancer as determined by pathologic Gleason scores. Further utilization of RSI techniques may serve to enhance standardized reporting systems.

  14. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  15. Magnetic Resonance Imaging Provides Added Value to the Prostate Cancer Prevention Trial Risk Calculator for Patients With Estimated Risk of High-grade Prostate Cancer Less Than or Equal to 10.

    Science.gov (United States)

    Kim, Eric H; Weaver, John K; Shetty, Anup S; Vetter, Joel M; Andriole, Gerald L; Strope, Seth A

    2017-04-01

    To determine the added value of prostate magnetic resonance imaging (MRI) to the Prostate Cancer Prevention Trial risk calculator. Between January 2012 and December 2015, 339 patients underwent prostate MRI prior to biopsy at our institution. MRI was considered positive if there was at least 1 Prostate Imaging Reporting and Data System 4 or 5 MRI suspicious region. Logistic regression was used to develop 2 models: biopsy outcome as a function of the (1) Prostate Cancer Prevention Trial risk calculator alone and (2) combined with MRI findings. When including all patients, the Prostate Cancer Prevention Trial with and without MRI models performed similarly (area under the curve [AUC] = 0.74 and 0.78, P = .06). When restricting the cohort to patients with estimated risk of high-grade (Gleason ≥7) prostate cancer ≤10%, the model with MRI outperformed the Prostate Cancer Prevention Trial alone model (AUC = 0.69 and 0.60, P = .01). Within this cohort of patients, there was no significant difference in discrimination between models for those with previous negative biopsy (AUC = 0.61 vs 0.63, P = .76), whereas there was a significant improvement in discrimination with the MRI model for biopsy-naïve patients (AUC = 0.72 vs 0.60, P = .01). The use of prostate MRI in addition to the Prostate Cancer Prevention Trial risk calculator provides a significant improvement in clinical risk discrimination for patients with estimated risk of high-grade (Gleason ≥7) prostate cancer ≤10%. Prebiopsy prostate MRI should be strongly considered for these patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

    International Nuclear Information System (INIS)

    Engstroem, K; Casares-Magaz, O; Muren, L; Roervik, J; Andersen, E

    2016-01-01

    Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with

  17. Operation and force analysis of the guide wire in a minimally invasive vascular interventional surgery robot system

    Science.gov (United States)

    Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian

    2015-03-01

    To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.

  18. MRI-guided laser-induced thermotherapy (LITT) of liver metastases: clinical evaluation

    International Nuclear Information System (INIS)

    Vogl, T.J.; Weinhold, N.; Mueller, P.; Mack, M.; Scholz, W.; Philipp, C.; Roggan, A.; Felix, R.

    1996-01-01

    The goal was to perform an evaluation of MRI-guided laser-induced thermotherapy (LITT) of liver metastases as a clinical method. In a prospective study, 50 patients with liver metastases of colorectal carcinoma (35 patients), or other primary tumors (15 patients) were treated with LITT. For preparation and intermittent controls of therapy, standardized MRI examinations were made. Online monitoring during the the LITT was done with temperature-sensitive T1-weighted sequences (FLASH-2D, TurboFLASH). All in all, 83 metastases of a volume between 1 and 282 cubic centimeters (median = ± 10 cm 3 ) were treated.During performance of the LITT, a decrease of signal intensity in the thermosensitive sequences was measured for the application area, and was correlated with fluorine-optical temperature measurements. The MRI-guided LITT is a novel, potential modality for treatment of liver metastases, and poses only minimal clinical risks. (orig./VHE) [de

  19. Robotic retroperitoneal partial nephrectomy: a step-by-step guide.

    Science.gov (United States)

    Ghani, Khurshid R; Porter, James; Menon, Mani; Rogers, Craig

    2014-08-01

    To describe a step-by-step guide for successful implementation of the retroperitoneal approach to robotic partial nephrectomy (RPN) PATIENTS AND METHODS: The patient is placed in the flank position and the table fully flexed to increase the space between the 12th rib and iliac crest. Access to the retroperitoneal space is obtained using a balloon-dilating device. Ports include a 12-mm camera port, two 8-mm robotic ports and a 12-mm assistant port placed in the anterior axillary line cephalad to the anterior superior iliac spine, and 7-8 cm caudal to the ipsilateral robotic port. Positioning and port placement strategies for successful technique include: (i) Docking robot directly over the patient's head parallel to the spine; (ii) incision for camera port ≈1.9 cm (1 fingerbreadth) above the iliac crest, lateral to the triangle of Petit; (iii) Seldinger technique insertion of kidney-shaped balloon dilator into retroperitoneal space; (iv) Maximising distance between all ports; (v) Ensuring camera arm is placed in the outer part of the 'sweet spot'. The retroperitoneal approach to RPN permits direct access to the renal hilum, no need for bowel mobilisation and excellent visualisation of posteriorly located tumours. © 2014 The Authors. BJU International © 2014 BJU International.

  20. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  1. MRI versus {sup 68}Ga-PSMA PET/CT for gross tumour volume delineation in radiation treatment planning of primary prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zamboglou, Constantinos; Kirste, Simon; Fechter, Tobias; Grosu, Anca-Ligia [University Medical Center Freiburg, Department of Radiation Oncology, Freiburg (Germany); German Cancer Consortium (DKTK), Heidelberg (Germany); Wieser, Gesche [University Medical Center Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Hennies, Steffen [University Medical Center Goettingen, Department of Radiation Oncology, Goettingen (Germany); Rempel, Irene; Soschynski, Martin; Langer, Mathias [University Medical Center Freiburg, Department of Radiology, Freiburg (Germany); Rischke, Hans Christian [University Medical Center Freiburg, Department of Radiation Oncology, Freiburg (Germany); Jilg, Cordula A. [University Medical Center Freiburg, Department of Urology, Freiburg (Germany); Meyer, Philipp T. [German Cancer Consortium (DKTK), Heidelberg (Germany); University Medical Center Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Bock, Michael [German Cancer Consortium (DKTK), Heidelberg (Germany); University Medical Center Freiburg, Department of Radiology, Freiburg (Germany)

    2016-05-15

    Multiparametric magnetic resonance imaging (mpMRI) is widely used in radiation treatment planning of primary prostate cancer (PCA). Focal dose escalation to the dominant intraprostatic lesions (DIPL) may lead to improved PCA control. Prostate-specific membrane antigen (PSMA) is overexpressed in most PCAs. {sup 68}Ga-labelled PSMA inhibitors have demonstrated promising results in detection of PCA with PET/CT. The aim of this study was to compare {sup 68}Ga-PSMA PET/CT with MRI for gross tumour volume (GTV) definition in primary PCA. This retrospective study included 22 patients with primary PCA analysed after {sup 68}Ga-PSMA PET/CT and mpMRI. GTVs were delineated on MR images by two radiologists (GTV-MRIrad) and two radiation oncologists separately. Both volumes were merged leading to GTV-MRIint. GTVs based on PET/CT were delineated by two nuclear medicine physicians in consensus (GTV-PET). Laterality (left, right, and left and right prostate lobes) on mpMRI, PET/CT and pathological analysis after biopsy were assessed. Mean GTV-MRIrad, GTV-MRIint and GTV-PET were 5.92, 3.83 and 11.41 cm{sup 3}, respectively. GTV-PET was significant larger then GTV-MRIint (p = 0.003). The MRI GTVs GTV-MRIrad and GTV-MRIint showed, respectively, 40 % and 57 % overlap with GTV-PET. GTV-MRIrad and GTV-MRIint included the SUVmax of GTV-PET in 12 and 11 patients (54.6 % and 50 %), respectively. In nine patients (47 %), laterality on mpMRI, PET/CT and histopathology after biopsy was similar. Ga-PSMA PET/CT and mpMRI provided concordant results for delineation of the DIPL in 47 % of patients (40 % - 54 % of lesions). GTV-PET was significantly larger than GTV-MRIint. {sup 68}Ga-PSMA PET/CT may have a role in radiation treatment planning for focal radiation to the DIPL. Exact correlation of PET and MRI images with histopathology is needed. (orig.)

  2. Stereotactic ultrasound for target volume definition in a patient with prostate cancer and bilateral total hip replacement.

    Science.gov (United States)

    Boda-Heggemann, Judit; Haneder, Stefan; Ehmann, Michael; Sihono, Dwi Seno Kuncoro; Wertz, Hansjörg; Mai, Sabine; Kegel, Stefan; Heitmann, Sigrun; von Swietochowski, Sandra; Lohr, Frank; Wenz, Frederik

    2015-01-01

    Target-volume definition for prostate cancer in patients with bilateral metal total hip replacements (THRs) is a challenge because of metal artifacts in the planning computed tomography (CT) scans. Magnetic resonance imaging (MRI) can be used for matching and prostate delineation; however, at a spatial and temporal distance from the planning CT, identical rectal and vesical filling is difficult to achieve. In addition, MRI may also be impaired by metal artifacts, even resulting in spatial image distortion. Here, we present a method to define prostate target volumes based on ultrasound images acquired during CT simulation and online-matched to the CT data set directly at the planning CT. A 78-year-old patient with cT2cNxM0 prostate cancer with bilateral metal THRs was referred to external beam radiation therapy. T2-weighted MRI was performed on the day of the planning CT with preparation according to a protocol for reproducible bladder and rectal filling. The planning CT was obtained with the immediate acquisition of a 3-dimensional ultrasound data set with a dedicated stereotactic ultrasound system for online intermodality image matching referenced to the isocenter by ceiling-mounted infrared cameras. MRI (offline) and ultrasound images (online) were thus both matched to the CT images for planning. Daily image guided radiation therapy (IGRT) was performed with transabdominal ultrasound and compared with cone beam CT. Because of variations in bladder and rectal filling and metal-induced image distortion in MRI, soft-tissue-based matching of the MRI to CT was not sufficient for unequivocal prostate target definition. Ultrasound-based images could be matched, and prostate, seminal vesicles, and target volumes were reliably defined. Daily IGRT could be successfully completed with transabdominal ultrasound with good accordance between cone beam CT and ultrasound. For prostate cancer patients with bilateral THRs causing artifacts in planning CTs, ultrasound referenced to

  3. A dimensionless dynamic contrast enhanced MRI parameter for intra-prostatic tumour target volume delineation: initial comparison with histology

    Science.gov (United States)

    Hrinivich, W. Thomas; Gibson, Eli; Gaed, Mena; Gomez, Jose A.; Moussa, Madeleine; McKenzie, Charles A.; Bauman, Glenn S.; Ward, Aaron D.; Fenster, Aaron; Wong, Eugene

    2014-03-01

    Purpose: T2 weighted and diffusion weighted magnetic resonance imaging (MRI) show promise in isolating prostate tumours. Dynamic contrast enhanced (DCE)-MRI has also been employed as a component in multi-parametric tumour detection schemes. Model-based parameters such as Ktrans are conventionally used to characterize DCE images and require arterial contrast agent (CR) concentration. A robust parameter map that does not depend on arterial input may be more useful for target volume delineation. We present a dimensionless parameter (Wio) that characterizes CR wash-in and washout rates without requiring arterial CR concentration. Wio is compared to Ktrans in terms of ability to discriminate cancer in the prostate, as demonstrated via comparison with histology. Methods: Three subjects underwent DCE-MRI using gadolinium contrast and 7 s imaging temporal resolution. A pathologist identified cancer on whole-mount histology specimens, and slides were deformably registered to MR images. The ability of Wio maps to discriminate cancer was determined through receiver operating characteristic curve (ROC) analysis. Results: There is a trend that Wio shows greater area under the ROC curve (AUC) than Ktrans with median AUC values of 0.74 and 0.69 respectively, but the difference was not statistically significant based on a Wilcoxon signed-rank test (p = 0.13). Conclusions: Preliminary results indicate that Wio shows potential as a tool for Ktrans QA, showing similar ability to discriminate cancer in the prostate as Ktrans without requiring arterial CR concentration.

  4. Contrast-enhanced versus systematic transrectal ultrasound-guided prostate cancer detection: An overview of techniques and a systematic review

    International Nuclear Information System (INIS)

    Heijmink, Stijn W.T.P.J.; Barentsz, Jelle O.

    2007-01-01

    An overview is given of the current conventional and contrast-specific transrectal ultrasound (TRUS) techniques for prostate imaging that may be used for guiding biopsy. Subsequently, a systematic literature search resulted in inclusion of four studies that directly compared systematic and contrast-enhanced-targeted TRUS-guided biopsy of the prostate. All four studies revealed that contrast-enhanced-targeted TRUS-guided biopsy significantly improved the positive biopsy core rate. In the largest study, the mean Gleason score of the contrast-enhanced-targeted TRUS-guided biopsies was significantly higher than that of the systematic biopsies. Future randomized clinical trials, preferably in a non-academic multi-institutional set-up, will have to be performed to confirm the value of contrast-enhanced-targeted TRUS-guided biopsy in regular clinical practice

  5. Atlas-guided prostate intensity modulated radiation therapy (IMRT) planning

    International Nuclear Information System (INIS)

    Sheng, Yang; Li, Taoran; Zhang, You; Lee, W Robert; Yin, Fang-Fang; Wu, Q Jackie; Ge, Yaorong

    2015-01-01

    An atlas-based IMRT planning technique for prostate cancer was developed and evaluated. A multi-dose atlas was built based on the anatomy patterns of the patients, more specifically, the percent distance to the prostate and the concaveness angle formed by the seminal vesicles relative to the anterior-posterior axis. A 70-case dataset was classified using a k-medoids clustering analysis to recognize anatomy pattern variations in the dataset. The best classification, defined by the number of classes or medoids, was determined by the largest value of the average silhouette width. Reference plans from each class formed a multi-dose atlas. The atlas-guided planning (AGP) technique started with matching the new case anatomy pattern to one of the reference cases in the atlas; then a deformable registration between the atlas and new case anatomies transferred the dose from the atlas to the new case to guide inverse planning with full automation. 20 additional clinical cases were re-planned to evaluate the AGP technique. Dosimetric properties between AGP and clinical plans were evaluated. The classification analysis determined that the 5-case atlas would best represent anatomy patterns for the patient cohort. AGP took approximately 1 min on average (corresponding to 70 iterations of optimization) for all cases. When dosimetric parameters were compared, the differences between AGP and clinical plans were less than 3.5%, albeit some statistical significances observed: homogeneity index (p  >  0.05), conformity index (p  <  0.01), bladder gEUD (p  <  0.01), and rectum gEUD (p  =  0.02). Atlas-guided treatment planning is feasible and efficient. Atlas predicted dose can effectively guide the optimizer to achieve plan quality comparable to that of clinical plans. (paper)

  6. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  7. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  8. Whole body MRI (WB-MRI) assessment of metastatic spread in prostate cancer: Therapeutic perspectives on targeted management of oligometastatic disease.

    Science.gov (United States)

    Larbi, Ahmed; Dallaudière, Benjamin; Pasoglou, Vasiliki; Padhani, Anwar; Michoux, Nicolas; Vande Berg, Bruno C; Tombal, Bertrand; Lecouvet, Frédéric E

    2016-08-01

    To determine the proportion of prostate cancer (PCa) patients with oligometastatic disease (≤3 synchronous lesions) using whole body magnetic resonance imaging with diffusion-weighted imaging (WB-MRI/DWI). To determine the proportion of patients with nodal disease confined within currently accepted target areas for extended lymph node dissection (eLND) and pelvic external beam radiation therapy (EBRT). Two radiologists reviewed WB-MRI/DWI studies in 96 consecutive newly diagnosed metastatic PCa patients; 46 patients with newly diagnosed castration naive PCa (mHNPC) and 50 patients with first appearance of metastasis during monitoring for non-metastatic castration resistant PCa (M0 to mCRPC). The distribution of metastatic deposits was assessed and the proportions of patients with oligometastatic disease and with LN metastases located within eLND and EBRT targets were determined. Twenty-eight percent of mHNPC and 50% of mCPRC entered the metastatic disease with ≤3 sites. Bone metastases (BM) were identified in 68.8% patients; 71.7% of mHNPC and 66% mCRPC patients. Most commonly involved areas were iliac bones and lumbar spine. Enlarged lymph nodes (LN) were detected in 68.7% of patients; 69.6% of mHNPC and 68.0% of mCRPC. Most commonly involved areas were para-aortic, inter-aortico-cava, and external iliac areas. BM and LN were detected concomitantly in 41% of mHNPC and 34% of mCRPC. Visceral metastases were detected in 6.7%. Metastatic disease was confined to LN located within the accepted boundaries of eLND or pelvic EBRT target areas in only ≤25% and ≤30% of patients, respectively. Non-invasive mapping of metastatic landing sites in PCa using WB-MRI/DWI shows that 28% of the mHNPC patients, and 52% of the mCRPC can be classified as oligometastatic, thus challenging the concept of metastatic targeted therapy. More than two thirds of metastatic patients have LN located outside the usually recommended targets of eLND and pelvic EBRT. Prophylactic or salvage

  9. Lesion volume predicts prostate cancer risk and aggressiveness: validation of its value alone and matched with prostate imaging reporting and data system score.

    Science.gov (United States)

    Martorana, Eugenio; Pirola, Giacomo Maria; Scialpi, Michele; Micali, Salvatore; Iseppi, Andrea; Bonetti, Luca Reggiani; Kaleci, Shaniko; Torricelli, Pietro; Bianchi, Giampaolo

    2017-07-01

    To demonstrate the association between magnetic resonance imaging (MRI) estimated lesion volume (LV), prostate cancer detection and tumour clinical significance, evaluating this variable alone and matched with Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) score. We retrospectively analysed 157 consecutive patients, with at least one prior negative systematic prostatic biopsy, who underwent transperineal prostate MRI/ultrasonography fusion-targeted biopsy between January 2014 and February 2016. Suspicious lesions were delineated using a 'region of interest' and the system calculated prostate volume and LV. Patients were divided in groups considering LV (≤0.5, 0.5-1, ≥1 mL) and PI-RADS score (1-5). We considered clinically significant prostate cancer as all cancers with a Gleason score of ≥3 + 4 as suggested by PI-RADS v2. A direct comparison between MRI estimated LV (MRI LV) and histological tumour volume (HTV) was done in 23 patients who underwent radical prostatectomy during the study period. Differences between MRI LV and HTV were assessed using the paired sample t-test. MRI LV and HTV concordance was verified using a Bland-Altman plot. The chi-squared test and logistic and ordinal regression models were used to evaluate difference in frequencies. The MRI LV and PI-RADS score were associated both with prostate cancer detection (both P prostate cancer detection (P Prostate cancer detection was 1.4-times higher for LVs of 0.5-1 mL and 1.8-times higher for LVs of ≥1 mL; significant prostate cancer detection was 2.6-times for LVs of 0.5-1 mL and 4-times for LVs of ≥1 mL. There was a positive correlation between MRI LV and HTV (r = 0.9876, P prostate cancer detection and with tumour clinical significance. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  10. Development of an MRI-Guided Intra-Prostatic Needle Placement System

    Science.gov (United States)

    2011-07-01

    Worcester Polytechnic Institute. Downloaded on August 09,2010 at 01:03:56 UTC from IEEE Xplore . Restrictions apply. Fig. 5. This mechanis provides for...Authorized licensed use limited to: Worcester Polytechnic Institute. Downloaded on August 09,2010 at 01:03:56 UTC from IEEE Xplore . Restrictions apply...A, Su H, Approaches to Creating and Controlling Motion in MRI, In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in

  11. Perspectives of transurethral robotic laser resection of the prostate: vaporization and coagulation effects with the Nd:YAG laser

    Science.gov (United States)

    Ho, Gideon; Teo, Ming Y.; Kwoh, Chee K.; Ng, Wan S.; Cheng, Wai S.

    2000-05-01

    A longer operating time and steeper learning curve in mastering the techniques for transurethral laser resection of the prostate are the main problems faced by surgeons compared to standard transurethral resection of the prostate (TURP). However, these disadvantages can be solved with the introduction of a treatment modality designed and developed based on an integrated system of computer, robotics and laser technology. In vitro experiments were carried out to determine variables affecting the vaporization and coagulation lesions, in order to identify the parameters that could optimize this modality. Human cadaveric prostate and fresh chicken breast tissues were irradiated with different parameters using continuous wave Nd:YAG laser fiber in contact with the tissue. The effects of irrigant flowrate, fiber/tissue angle of inclination, number of passes, direction, speed and power of lase on the volume of tissue vaporized and coagulated, were assessed. A non-contact optical coordinate measuring machine was used to measure the depth and width of the vaporized and coagulated lesion. Results reveal that for each directional vaporization path (forward, clockwise and counter-clockwise), power and speed of lase are the most significant parameters influencing the volume of the vaporized and coagulated lesion. Optimized values of the power and speed of lase at 100 W and 1 - 3 mm/s respectively were obtained from the experiments when the tissues were irradiated in the forward, clockwise and counter-clockwise directions. It was concluded from our study to quantify tissue removal and damage, optimized values of irradiation power and speed could be obtained and implemented in the procedure of transurethral robotic laser resection of the prostate.

  12. Multiparametric magnetic resonance imaging characteristics of prostate tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Yue; Huang, Lixiang; Zhang, Xiaodong; Ji, Qian; Shen, Wen [Dept. of Radiology, Tianjin First Central Hospital, Tianjin (China)

    2015-08-15

    To describe the multiparametric magnetic resonance imaging (MRI) appearance of prostate tuberculosis. Six patients with prostate tuberculosis were analyzed retrospectively. The mean age of the patients was 60.5 years (range, 48-67 years). The mean prostate specific antigen concentration was 6.62 ng/mL (range, 0.54-14.57 ng/mL). All patients underwent a multiparametric MRI examination. The histopathological results were obtained from biopsies in four men and from transurethral resection of the prostate in two men after the MRI examination. Nodular (33%, 2/6 patients) and diffuse lesions (67%, 4/6 patients) were seen on MRI. The nodular lesions were featured by extremely low signal intensity (similar to that of muscle) on T2-weighted imaging (T2WI). The T2WI signal intensity of the diffuse lesions was low but higher than that of muscle, which showed high signal intensity on diffusion weighted imaging and low signal intensity on an apparent diffusion coefficient map. MR spectroscopic imaging of this type showed a normal-like spectrum. Abscesses were found in one patient with the nodular type and in one with the diffuse type. The appearance of prostate tuberculosis on MRI can be separated into multiple nodular and diffuse types. Multiparametric MRI may offer useful information for diagnosing prostate tuberculosis.

  13. Prostate cancer detection by prebiopsy 3.0-tesla magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nishida, Sachiyo; Kinoshita, Hidefumi; Mishima, Takao; Kurokawa, Hiroaki; Sakaida, Noriko; Matsuda, Tadashi

    2011-01-01

    The diagnostic value of 3.0-Tesla magnetic resonance imaging (MRI) for prostate cancer remains to be determined. The aim of the present study was to assess the features of prostate cancer detectable by prebiopsy 3.0-Tesla MRI. From January 2007 through to December 2008, 116 patients who were examined by prebiopsy 3.0-Tesla MRI underwent radical prostatectomy for localized prostate cancer. Prostate specimens were examined to see whether the largest cancer area was the same as the area indicated on the MRI. Univariate and multivariate logistic regression analyses were conducted to identify variables predictive of agreement between MRI and histopathological findings. Sixty-six (56.9%) patients were suspected of having prostate cancer on the basis of MRI findings. In 49 of these patients (74.2%), it was considered that there was agreement between the abnormal area on the MRI and the index tumor. Univariate analysis revealed that there were significant differences in abnormal digital rectal examination, capsular penetration, the diameter of the index tumor of the radical prostatectomy specimen, and the Gleason scores of the biopsy and radical prostatectomy specimens. Multivariate analysis revealed that the Gleason score of the radical prostatectomy specimen was associated with the accurate detection of the prostate cancer by MRI (P=0.0177). In conclusion, 3.0-Tesla MRI tends to accurately diagnose prostate cancer with high tumor burden and aggressiveness. Multimodal examination (T2-weighted imaging, dynamic contrast-enhanced imaging, and diffusion-weighted imaging) is recommended for the diagnosis of prostate cancer using 3.0-Tesla MRI. (author)

  14. A Robotic Guide for Blind People. Part 1. A Multi-National Survey of the Attitudes, Requirements and Preferences of Potential End-Users

    Directory of Open Access Journals (Sweden)

    Marion A. Hersh

    2010-01-01

    Full Text Available This paper reports the results of a multi-national survey in several different countries on the attitudes, requirements and preferences of blind and visually impaired people for a robotic guide. The survey is introduced by a brief overview of existing work on robotic travel aids and other mobile robotic devices. The questionnaire comprises three sections on personal information about respondents, existing use of mobility and navigation devices and the functions and other features of a robotic guide. The survey found that respondents were very interested in the robotic guide having a number of different functions and being useful in a wide range of circumstances. They considered the robot's appearance to be very important but did not like any of the proposed designs. From their comments, respondents wanted the robot to be discreet and inconspicuous, small, light weight and portable, easy to use, robust to damage, require minimal maintenance, have a long life and a long battery life.

  15. Detection of local recurrent prostate cancer after radical prostatectomy in terms of salvage radiotherapy using dynamic contrast enhanced-MRI without endorectal coil

    Directory of Open Access Journals (Sweden)

    Rischke Hans Christian

    2012-10-01

    Full Text Available Abstract Purpose To evaluate the value of dynamic contrast enhanced Magnetic Resonance Imaging (DCE-MRI without endorectal coil (EC in the detection of local recurrent prostate cancer (PC after radical prostatectomy (RP. Material and methods Thirty-three patients with recurrent PC underwent DCE-MRI without EC before salvage radiotherapy (RT. At median 15 (mean 16±4.9, range 12–27 months after completion of RT all patients showed complete biochemical response. Additional follow up post RT DCE-MRI scans were available. Prostate specific antigen (PSA levels at the time of imaging were correlated to the imaging findings. Results In 22/33 patients (67% early contrast enhancing nodules were detected in the post-prostatectomy fossa on pre-RT DCE-MRI images. The average pre-RT PSA level of the 22 patients with positive pre-RT DCE-MRI findings was significantly higher (mean, 0.74±0.64 ng/mL compared to the pre-RT PSA level of the 11 patients with negative pre-RT DCE-MRI (mean, 0.24±0.13 ng/mL (p Conclusions This is the first study that shows that DCE-MRI without EC can detect local recurrent PC with an estimated accuracy of 83% at low PSA levels. All false negative DCE-MRI scans were detected using a PSA cut-off of ≥0.54 ng/mL.

  16. Image-guided robotic radiosurgery for spinal metastases

    International Nuclear Information System (INIS)

    Gibbs, Iris C.; Kamnerdsupaphon, Pimkhuan; Ryu, Mi-Ryeong; Dodd, Robert; Kiernan, Michaela; Chang, Steven D.; Adler, John R.

    2007-01-01

    Background and Purpose: To determine the effectiveness and safety of image-guided robotic radiosurgery for spinal metastases. Materials/Methods: From 1996 to 2005, 74 patients with 102 spinal metastases were treated using the CyberKnife TM at Stanford University. Sixty-two (84%) patients were symptomatic. Seventy-four percent (50/68) of previously treated patients had prior radiation. Using the CyberKnife TM , 16-25 Gy in 1-5 fractions was delivered. Patients were followed clinically and radiographically for at least 3 months or until death. Results: With mean follow-up of 9 months (range 0-33 months), 36 patients were alive and 38 were dead at last follow-up. No death was treatment related. Eighty-four (84%) percent of symptomatic patients experienced improvement or resolution of symptoms after treatment. Three patients developed treatment-related spinal injury. Analysis of dose-volume parameters and clinical parameters failed to identify predictors of spinal cord injury. Conclusions: Robotic radiosurgery is effective and generally safe for spinal metastases even in previously irradiated patients

  17. Localized irradiation of mouse legs using an image-guided robotic linear accelerator.

    Science.gov (United States)

    Kufeld, Markus; Escobar, Helena; Marg, Andreas; Pasemann, Diana; Budach, Volker; Spuler, Simone

    2017-04-01

    To investigate the potential of human satellite cells in muscle regeneration small animal models are useful to evaluate muscle regeneration. To suppress the inherent regeneration ability of the tibialis muscle of mice before transplantation of human muscle fibers, a localized irradiation of the mouse leg should be conducted. We analyzed the feasibility of an image-guided robotic irradiation procedure, a routine treatment method in radiation oncology, for the focal irradiation of mouse legs. After conducting a planning computed tomography (CT) scan of one mouse in its customized mold a three-dimensional dose plan was calculated using a dedicated planning workstation. 18 Gy have been applied to the right anterior tibial muscle of 4 healthy and 12 mice with immune defect in general anesthesia using an image-guided robotic linear accelerator (LINAC). The mice were fixed in a customized acrylic mold with attached fiducial markers for image guided tracking. All 16 mice could be irradiated as prevised without signs of acute radiation toxicity or anesthesiological side effects. The animals survived until scarification after 8, 21 and 49 days as planned. The procedure was straight forward and the irradiation process took 5 minutes to apply the dose of 18 Gy. Localized irradiation of mice legs using a robotic LINAC could be conducted as planned. It is a feasible procedure without recognizable side effects. Image guidance offers precise dose delivery and preserves adjacent body parts and tissues.

  18. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.

    Science.gov (United States)

    Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul

    2018-02-11

    In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.

  19. Ultrasonically guided 125iodine seed implantation with external radiation in management of localized prostatic carcinoma

    DEFF Research Database (Denmark)

    Iversen, P; Bak, M; Juul, N

    1989-01-01

    Thirty-three patients with localized prostatic carcinoma (16 poorly differentiated) were treated with transperineal 125Iodine seed implantation (160 Gy) guided by transrectal ultrasonography and subsequent external beam irradiation (47.4 Gy). The observation time was six to sixty-eight months...... with a median follow-up of thirty-five months. Median change in prostatic volume was a reduction of 35 percent. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after one to two years, revealing still malignant histology in 12 (48%). Development of distant metastases occurred...

  20. Interactive, multi-modality image registrations for combined MRI/MRSI-planned HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Galen Reed

    2011-03-01

    Full Text Available Purpose: This study presents the steps and criteria involved in the series of image registrations used clinically during the planning and dose delivery of focal high dose-rate (HDR brachytherapy of the prostate. Material and methods: Three imaging modalities – Magnetic Resonance Imaging (MRI, Magnetic Resonance Spectroscopic Imaging (MRSI, and Computed Tomography (CT – were used at different steps during the process. MRSI is used for identification of dominant intraprosatic lesions (DIL. A series of rigid and nonrigid transformations were applied to the data to correct for endorectal-coil-induced deformations and for alignment with the planning CT. Mutual information was calculated as a morphing metric. An inverse planning optimization algorithm was applied to boost dose to the DIL while providing protection to the urethra, penile bulb, rectum, and bladder. Six prostate cancer patients were treated using this protocol. Results: The morphing algorithm successfully modeled the probe-induced prostatic distortion. Mutual information calculated between the morphed images and images acquired without the endorectal probe showed a significant (p = 0.0071 increase to that calculated between the unmorphed images and images acquired without the endorectal probe. Both mutual information and visual inspection serve as effective diagnostics of image morphing. The entire procedure adds less than thirty minutes to the treatment planning. Conclusion: This work demonstrates the utility of image transformations and registrations to HDR brachytherapy of prostate cancer.