  1. Association between breast cancer, breast density, and body adiposity evaluated by MRI

    International Nuclear Information System (INIS)

    Zhu, Wenlian; Huang, Peng; Macura, Katarzyna J.; Artemov, Dmitri

    2016-01-01

    Despite the lack of reliable methods with which to measure breast density from 2D mammograms, numerous studies have demonstrated a positive association between breast cancer and breast density. The goal of this study was to study the association between breast cancer and body adiposity, as well as breast density quantitatively assessed from 3D MRI breast images. Breast density was calculated from 3D T1-weighted MRI images. The thickness of the upper abdominal adipose layer was used as a surrogate marker for body adiposity. We evaluated the correlation between breast density, age, body adiposity, and breast cancer. Breast density was calculated for 410 patients with unilateral invasive breast cancer, 73 patients with ductal carcinoma in situ (DCIS), and 361 controls without breast cancer. Breast density was inversely related to age and the thickness of the upper abdominal adipose layer. Breast cancer was only positively associated with body adiposity and age. Age and body adiposity are predictive of breast density. Breast cancer was not associated with breast density; however, it was associated with the thickness of the upper abdominal adipose layer, a surrogate marker for body adiposity. Our results based on a limited number of patients warrant further investigations. (orig.)

  2. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  3. Agreement of mammographic measures of volumetric breast density to MRI.

    Science.gov (United States)

    Wang, Jeff; Azziz, Ania; Fan, Bo; Malkov, Serghei; Klifa, Catherine; Newitt, David; Yitta, Silaja; Hylton, Nola; Kerlikowske, Karla; Shepherd, John A

    2013-01-01

    Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  4. Association between mammogram density and background parenchymal enhancement of breast MRI

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Wang, Yunzhi; Zarafshani, Ali; Qian, Wei; Liu, Hong; Zheng, Bin

    2018-02-01

    Breast density has been widely considered as an important risk factor for breast cancer. The purpose of this study is to examine the association between mammogram density results and background parenchymal enhancement (BPE) of breast MRI. A dataset involving breast MR images was acquired from 65 high-risk women. Based on mammography density (BIRADS) results, the dataset was divided into two groups of low and high breast density cases. The Low-Density group has 15 cases with mammographic density (BIRADS 1 and 2), while the High-density group includes 50 cases, which were rated by radiologists as mammographic density BIRADS 3 and 4. A computer-aided detection (CAD) scheme was applied to segment and register breast regions depicted on sequential images of breast MRI scans. CAD scheme computed 20 global BPE features from the entire two breast regions, separately from the left and right breast region, as well as from the bilateral difference between left and right breast regions. An image feature selection method namely, CFS method, was applied to remove the most redundant features and select optimal features from the initial feature pool. Then, a logistic regression classifier was built using the optimal features to predict the mammogram density from the BPE features. Using a leave-one-case-out validation method, the classifier yields the accuracy of 82% and area under ROC curve, AUC=0.81+/-0.09. Also, the box-plot based analysis shows a negative association between mammogram density results and BPE features in the MRI images. This study demonstrated a negative association between mammogram density and BPE of breast MRI images.

  5. Breast density estimation from high spectral and spatial resolution MRI

    Science.gov (United States)

    Li, Hui; Weiss, William A.; Medved, Milica; Abe, Hiroyuki; Newstead, Gillian M.; Karczmar, Gregory S.; Giger, Maryellen L.

    2016-01-01

    Abstract. A three-dimensional breast density estimation method is presented for high spectral and spatial resolution (HiSS) MR imaging. Twenty-two patients were recruited (under an Institutional Review Board--approved Health Insurance Portability and Accountability Act-compliant protocol) for high-risk breast cancer screening. Each patient received standard-of-care clinical digital x-ray mammograms and MR scans, as well as HiSS scans. The algorithm for breast density estimation includes breast mask generating, breast skin removal, and breast percentage density calculation. The inter- and intra-user variabilities of the HiSS-based density estimation were determined using correlation analysis and limits of agreement. Correlation analysis was also performed between the HiSS-based density estimation and radiologists’ breast imaging-reporting and data system (BI-RADS) density ratings. A correlation coefficient of 0.91 (pdensity estimations. An interclass correlation coefficient of 0.99 (pdensity estimations. A moderate correlation coefficient of 0.55 (p=0.0076) was observed between HiSS-based breast density estimations and radiologists’ BI-RADS. In summary, an objective density estimation method using HiSS spectral data from breast MRI was developed. The high reproducibility with low inter- and low intra-user variabilities shown in this preliminary study suggest that such a HiSS-based density metric may be potentially beneficial in programs requiring breast density such as in breast cancer risk assessment and monitoring effects of therapy. PMID:28042590

  6. Quantitative breast density analysis using tomosynthesis and comparison with MRI and digital mammography.

    Science.gov (United States)

    Moon, Woo Kyung; Chang, Jie-Fan; Lo, Chung-Ming; Chang, Jung Min; Lee, Su Hyun; Shin, Sung Ui; Huang, Chiun-Sheng; Chang, Ruey-Feng

    2018-02-01

    Breast density at mammography has been used as markers of breast cancer risk. However, newly introduced tomosynthesis and computer-aided quantitative method could provide more reliable breast density evaluation. In the experiment, 98 tomosynthesis image volumes were obtained from 98 women. For each case, an automatic skin removal was used and followed by a fuzzy c-mean (FCM) classifier which separated the fibroglandular tissues from other tissues in breast area. Finally, percent of breast density and breast volume were calculated and the results were compared with MRI. In addition, the percent of breast density and breast area of digital mammography calculated using the software Cumulus (University of Toronto, Toronto, ON, Canada.) were also compared with 3-D modalities. Percent of breast density and breast volume, which were computed from tomosynthesis, MRI and digital mammography were 17.37% ± 4.39% and 607.12 cm 3  ± 323.01 cm 3 , 20.3% ± 8.6% and 537.59 cm 3  ± 287.74 cm 3 , and 12.03% ± 4.08%, respectively. There were significant correlations on breast density as well as volume between tomosynthesis and MRI (R = 0.482 and R = 0.805), tomosynthesis and breast density with breast area of digital mammography (R = 0.789 and R = 0.877), and MRI and breast density with breast area of digital mammography (R = 0.482 and R = 0.857) (all P values density and breast volume evaluated from tomosynthesis, MRI and breast density and breast area of digital mammographic images have significant correlations and indicate that tomosynthesis could provide useful 3-D information on breast density through proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Breast fat volume measurement using wide-bore 3 T MRI: comparison of traditional mammographic density evaluation with MRI density measurements using automatic segmentation.

    Science.gov (United States)

    Petridou, E; Kibiro, M; Gladwell, C; Malcolm, P; Toms, A; Juette, A; Borga, M; Dahlqvist Leinhard, O; Romu, T; Kasmai, B; Denton, E

    2017-07-01

    To compare magnetic resonance imaging (MRI)-derived breast density measurements using automatic segmentation algorithms with radiologist estimations using the Breast Imaging Reporting and Data Systems (BI-RADS) density classification. Forty women undergoing mammography and dynamic breast MRI as part of their clinical management were recruited. Fat-water separated MRI images derived from a two-point Dixon technique, phase-sensitive reconstruction, and atlas-based segmentation were obtained before and after intravenous contrast medium administration. Breast density was assessed using software from Advanced MR Analytics (AMRA), Linköping, Sweden, with results compared to the widely used four-quartile quantitative BI-RADS scale. The proportion of glandular tissue in the breast on MRI was derived from the AMRA sequence. The mean unenhanced breast density was 0.31±0.22 (mean±SD; left) and 0.29±0.21 (right). Mean breast density on post-contrast images was 0.32±0.19 (left) and 0.32±0.2 (right). There was "almost perfect" correlation between pre- and post-contrast breast density quantification: Spearman's correlation rho=0.98 (95% confidence intervals [CI]: 0.97-0.99; left) and rho=0.99 (95% CI: 0.98-0.99; right). The 95% limits of agreement were -0.11-0.08 (left) and -0.08-0.03 (right). Interobserver reliability for BI-RADS was "substantial": weighted Kappa k=0.8 (95% CI: 0.74-0.87). The Spearman correlation coefficient between BI-RADS and MRI breast density was rho=0.73 (95% CI: 0.60-0.82; left) and rho=0.75 (95% CI: 0.63-0.83; right) which was also "substantial". The AMRA sequence provides a fully automated, reproducible, objective assessment of fibroglandular breast tissue proportion that correlates well with mammographic assessment of breast density with the added advantage of avoidance of ionising radiation. Copyright © 2017 The Royal College of Radiologists. All rights reserved.

  8. Reproducible automated breast density measure with no ionizing radiation using fat-water decomposition MRI.

    Science.gov (United States)

    Ding, Jie; Stopeck, Alison T; Gao, Yi; Marron, Marilyn T; Wertheim, Betsy C; Altbach, Maria I; Galons, Jean-Philippe; Roe, Denise J; Wang, Fang; Maskarinec, Gertraud; Thomson, Cynthia A; Thompson, Patricia A; Huang, Chuan

    2018-04-06

    Increased breast density is a significant independent risk factor for breast cancer, and recent studies show that this risk is modifiable. Hence, breast density measures sensitive to small changes are desired. Utilizing fat-water decomposition MRI, we propose an automated, reproducible breast density measurement, which is nonionizing and directly comparable to mammographic density (MD). Retrospective study. The study included two sample sets of breast cancer patients enrolled in a clinical trial, for concordance analysis with MD (40 patients) and reproducibility analysis (10 patients). The majority of MRI scans (59 scans) were performed with a 1.5T GE Signa scanner using radial IDEAL-GRASE sequence, while the remaining (seven scans) were performed with a 3T Siemens Skyra using 3D Cartesian 6-echo GRE sequence with a similar fat-water separation technique. After automated breast segmentation, breast density was calculated using FraGW, a new measure developed to reliably reflect the amount of fibroglandular tissue and total water content in the entire breast. Based on its concordance with MD, FraGW was calibrated to MR-based breast density (MRD) to be comparable to MD. A previous breast density measurement, Fra80-the ratio of breast voxels with density changes and treatment response. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  9. Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: a postmortem study.

    Science.gov (United States)

    Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q; Ducote, Justin L; Su, Min-Ying; Molloi, Sabee

    2013-12-01

    Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left-right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left-right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left-right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. The investigated CLIC method

  10. Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

    International Nuclear Information System (INIS)

    Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q.; Ducote, Justin L.; Su, Min-Ying; Molloi, Sabee

    2013-01-01

    Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction

  11. Background parenchymal enhancement on breast MRI and mammographic breast density: correlation with tumour characteristics

    International Nuclear Information System (INIS)

    Kim, M.Y.; Choi, N.; Yang, J.-H.; Yoo, Y.B.; Park, K.S.

    2015-01-01

    Aim: To investigate the relationship between mammographic breast density (MGD) and background parenchymal enhancement (BPE) at breast MRI and histopathological features of invasive breast cancers. Materials and methods: A total of 178 women with unilateral invasive breast cancer who preoperatively underwent mammography and breast MRI were included in the study. Two radiologists rated MGD and BPE according to BI-RADS criteria in consensus. The relationship between MGD and BPE was investigated, and compared with histopathological features of invasive breast cancers according to the level of MGD and BPE. Results: At MRI, there is no significant difference in the distribution of MGD and BPE of the contralateral breast in women with invasive breast cancer according to menopausal status (p=0.226, 0.384). Women with high MGD (>50% glandular) were more likely to have oestrogen-receptor (ER)-positive breast cancer (p=0.045) and progesterone receptor (PR)-positive breast cancer (p=0.020). With regard to BPE, PR positivity correlated with moderate or marked BPE with borderline significance (p=0.054). Multivariate logistic regression analyses revealed that women with high MGD were less likely to have triple-negative (i.e., a cancer that is ER negative, PR negative, and human epidermal growth factor receptor type 2 [HER2] negative) breast cancer compared with ER (+)/HER2 (−) cancer (OR=0.231, 95% CI: 0.070, 0.760; p=0.016). No association between the histological tumour characteristics and BPE was observed. Conclusion: In women with invasive breast cancer, high MGD is associated with ER positivity of the invasive breast cancer. However, at MRI, BPE of the contralateral breast seems to be independent of tumour characteristics. -- Highlights: •There is no difference in distribution of MGD and BPE of contralateral breast on MRI. •High MGD is associated with ER positivity of the invasive breast cancer. •BPE of the contralateral breast on MRI is independent of tumor

  12. Should breast MRI be performed with adjustment for the phase in patients’ menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2012-01-01

    Purpose: The purpose of this study was to assess the correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle. Material and methods: The background enhancement of bilateral breast MRI and the breast density of mammography in 146 consecutive women without adjusting for the phase in patients’ menstrual cycle were reviewed. The breast density was classified into four categories according to the American College of Radiology the Breast Imaging Reporting and Data System lexicon. The background enhancement was classified into four categories: minimal, mild, moderate, and marked. The correlations of mammographic breast density as well as age with background enhancement on breast MRI were examined. Results: There was a significant correlation between mammographic breast density and background enhancement (p = 0.011). All nine cases with almost completely fat mammographic breast density showed minimal (78%) or mild (12%) background enhancement on breast MRI. There was a significant inverse correlation between age and background enhancement (p < 0.0001). Younger patients with dense breasts were more likely to demonstrate moderate/marked background enhancement. Conclusion: When no adjusting for the phase in patients’ menstrual cycle, a significant correlation was observed between background enhancement and mammographic density. A significant inverse correlation was also observed between age and background enhancement.

  13. Double-blind randomized 12-month soy intervention had no effects on breast MRI fibroglandular tissue density or mammographic density

    Science.gov (United States)

    Wu, Anna H.; Spicer, Darcy; Garcia, Agustin; Tseng, Chiu-Chen; Hovanessian-Larsen, Linda; Sheth, Pulin; Martin, Sue Ellen; Hawes, Debra; Russell, Christy; McDonald, Heather; Tripathy, Debu; Su, Min-Ying; Ursin, Giske; Pike, Malcolm C.

    2015-01-01

    Soy supplementation by breast cancer patients remains controversial. No controlled intervention studies have investigated the effects of soy supplementation on mammographic density in breast cancer patients. We conducted a double-blind, randomized, placebo-controlled intervention study in previously treated breast cancer patients (n=66) and high-risk women (n=29). We obtained digital mammograms and breast magnetic resonance imaging (MRI) scans at baseline and after 12 months of daily soy (50 mg isoflavones per day) (n=46) or placebo (n=49) tablet supplementation. The total breast area (MA) and the area of mammographic density (MD) on the mammogram was measured using a validated computer-assisted method, and mammographic density percent (MD% = 100 × MD/MA) was determined. A well-tested computer algorithm was used to quantitatively measure the total breast volume (TBV) and fibroglandular tissue volume (FGV) on the breast MRI, and the FGV percent (FGV% = 100 × FGV/TBV) was calculated. On the basis of plasma soy isoflavone levels, compliance was excellent. Small decreases in MD% measured by the ratios of month 12 to baseline levels, were seen in the soy (0.95) and the placebo (0.87) groups; these changes did not differ between the treatments (P=0.38). Small decreases in FGV% were also found in both the soy (0.90) and the placebo (0.92) groups; these changes also did not differ between the treatments (P=0.48). Results were comparable in breast cancer patients and high-risk women. We found no evidence that soy supplementation would decrease mammographic density and that MRI might be more sensitive to changes in density than mammography. PMID:26276750

  14. Selective magnetic resonance imaging (MRI) in invasive lobular breast cancer based on mammographic density: does it lead to an appropriate change in surgical treatment?

    Science.gov (United States)

    Bansal, Gaurav J; Santosh, Divya; Davies, Eleri L

    2016-01-01

    The purpose of this study was to evaluate whether high mammographic density can be used as one of the selection criteria for MRI in invasive lobular breast cancer (ILC). In our institute, high breast density has been used as one of the indications for performing MRI scan in patients with ILC. We divided the patients in two groups, one with MRI performed pre-operatively and other without MRI. We compared their surgical procedures and analyzed whether surgical plan was altered after MRI. In case of alteration of plan, we analyzed whether the change was adequate by comparing post-operative histological findings. Between 2011 and 2015, there were a total of 1601 breast cancers with 97 lobular cancers, out of which 36 had pre-operative MRI and 61 had no MRI scan. 12 (33.3%) had mastectomy following MRI, out of which 9 (25%) had change in surgical plan from conservation to mastectomy following MRI. There were no unnecessary mastectomies in the MRI group. However, utilization of MRI in this cohort of patients did not reduce reoperation rate (19.3%). Lobular carcinoma in situ (LCIS) was identified in 60% of reoperations on post-surgical histology. Patients in the "No MRI" group had higher mastectomy rate 26 (42.6%), which was again appropriate. High mammographic density is a useful risk stratification criterion for selective MRI in ILC within a multidisciplinary team meeting setting. Provided additional lesions identified on MRI are confirmed with biopsy, pre-operative MRI does not cause unnecessary mastectomies. Used in this selective manner, reoperation rates were not eliminated, albeit reduced when compared to literature. High mammographic breast density can be used as one of the selection criteria for pre-operative MRI in ILC without an increase in inappropriate mastectomies with potential time and cost savings. In this cohort, re-excisions were not reduced markedly with pre-operative MRI.

  15. Template-based automatic breast segmentation on MRI by excluding the chest region

    OpenAIRE

    Lin, M; Chen, JH; Wang, X; Chan, S; Chen, S; Su, MY

    2013-01-01

    Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as th e template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the c...

  16. A new bias field correction method combining N3 and FCM for improved segmentation of breast density on MRI.

    Science.gov (United States)

    Lin, Muqing; Chan, Siwa; Chen, Jeon-Hor; Chang, Daniel; Nie, Ke; Chen, Shih-Ting; Lin, Cheng-Ju; Shih, Tzu-Ching; Nalcioglu, Orhan; Su, Min-Ying

    2011-01-01

    Quantitative breast density is known as a strong risk factor associated with the development of breast cancer. Measurement of breast density based on three-dimensional breast MRI may provide very useful information. One important step for quantitative analysis of breast density on MRI is the correction of field inhomogeneity to allow an accurate segmentation of the fibroglandular tissue (dense tissue). A new bias field correction method by combining the nonparametric nonuniformity normalization (N3) algorithm and fuzzy-C-means (FCM)-based inhomogeneity correction algorithm is developed in this work. The analysis is performed on non-fat-sat T1-weighted images acquired using a 1.5 T MRI scanner. A total of 60 breasts from 30 healthy volunteers was analyzed. N3 is known as a robust correction method, but it cannot correct a strong bias field on a large area. FCM-based algorithm can correct the bias field on a large area, but it may change the tissue contrast and affect the segmentation quality. The proposed algorithm applies N3 first, followed by FCM, and then the generated bias field is smoothed using Gaussian kernal and B-spline surface fitting to minimize the problem of mistakenly changed tissue contrast. The segmentation results based on the N3+FCM corrected images were compared to the N3 and FCM alone corrected images and another method, coherent local intensity clustering (CLIC), corrected images. The segmentation quality based on different correction methods were evaluated by a radiologist and ranked. The authors demonstrated that the iterative N3+FCM correction method brightens the signal intensity of fatty tissues and that separates the histogram peaks between the fibroglandular and fatty tissues to allow an accurate segmentation between them. In the first reading session, the radiologist found (N3+FCM > N3 > FCM) ranking in 17 breasts, (N3+FCM > N3 = FCM) ranking in 7 breasts, (N3+FCM = N3 > FCM) in 32 breasts, (N3+FCM = N3 = FCM) in 2 breasts, and (N3 > N3

  17. Breast density as indicator for the use of mammography or MRI to screen women with familial risk for breast cancer (FaMRIsc: a multicentre randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Saadatmand Sepideh

    2012-10-01

    Full Text Available Abstract Background To reduce mortality, women with a family history of breast cancer often start mammography screening at a younger age than the general population. Breast density is high in over 50% of women younger than 50 years. With high breast density, breast cancer incidence increases, but sensitivity of mammography decreases. Therefore, mammography might not be the optimal method for breast cancer screening in young women. Adding MRI increases sensitivity, but also the risk of false-positive results. The limitation of all previous MRI screening studies is that they do not contain a comparison group; all participants received both MRI and mammography. Therefore, we cannot empirically assess in which stage tumours would have been detected by either test. The aim of the Familial MRI Screening Study (FaMRIsc is to compare the efficacy of MRI screening to mammography for women with a familial risk. Furthermore, we will assess the influence of breast density. Methods/Design This Dutch multicentre, randomized controlled trial, with balanced randomisation (1:1 has a parallel grouped design. Women with a cumulative lifetime risk for breast cancer due to their family history of ≥20%, aged 30–55 years are eligible. Identified BRCA1/2 mutation carriers or women with 50% risk of carrying a mutation are excluded. Group 1 receives yearly mammography and clinical breast examination (n = 1000, and group 2 yearly MRI and clinical breast examination, and mammography biennially (n = 1000. Primary endpoints are the number and stage of the detected breast cancers in each arm. Secondary endpoints are the number of false-positive results in both screening arms. Furthermore, sensitivity and positive predictive value of both screening strategies will be assessed. Cost-effectiveness of both strategies will be assessed. Analyses will also be performed with mammographic density as stratification factor. Discussion Personalized breast cancer screening

  18. Template-based automatic breast segmentation on MRI by excluding the chest region

    International Nuclear Information System (INIS)

    Lin, Muqing; Chen, Jeon-Hor; Wang, Xiaoyong; Su, Min-Ying; Chan, Siwa; Chen, Siping

    2013-01-01

    Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as the template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the chest body region on a middle slice was used as the template. Within the chest template, three body landmarks (thoracic spine and bilateral boundary of the pectoral muscle) were identified for performing the initial V-shape cut to determine the posterior lateral boundary of the breast. The chest template was mapped to each subject's image space to obtain a subject-specific chest model for exclusion. On the remaining image, the chest wall muscle was identified and excluded to obtain clean breast segmentation. The chest and muscle boundaries determined on the middle slice were used as the reference for the segmentation of adjacent slices, and the process continued superiorly and inferiorly until all 3D slices were segmented. The segmentation results were evaluated by an experienced radiologist to mark voxels that were wrongly included or excluded for error analysis. Results: The breast volumes measured by the proposed algorithm were very close to the radiologist's corrected volumes, showing a % difference ranging from 0.01% to 3.04% in 30 tested subjects with a mean of 0.86% ± 0.72%. The total error was calculated by adding the inclusion and the exclusion errors (so they did not cancel each other out), which ranged from 0.05% to 6.75% with a mean of 3.05% ± 1.93%. The fibroglandular tissue segmented within the breast region determined by the algorithm and the radiologist were also very close, showing a % difference ranging from 0.02% to 2.52% with a mean of 1.03% ± 1.03%. The

  19. Template-based automatic breast segmentation on MRI by excluding the chest region

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Muqing [Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697-5020 and National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, 518060 China (China); Chen, Jeon-Hor [Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697-5020 and Department of Radiology, E-Da Hospital and I-Shou University, Kaohsiung 82445, Taiwan (China); Wang, Xiaoyong; Su, Min-Ying, E-mail: msu@uci.edu [Tu and Yuen Center for Functional Onco-Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697-5020 (United States); Chan, Siwa [Department of Radiology, Taichung Veterans General Hospital, Taichung 40407, Taiwan (China); Chen, Siping [National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, 518060 China (China)

    2013-12-15

    Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as the template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the chest body region on a middle slice was used as the template. Within the chest template, three body landmarks (thoracic spine and bilateral boundary of the pectoral muscle) were identified for performing the initial V-shape cut to determine the posterior lateral boundary of the breast. The chest template was mapped to each subject's image space to obtain a subject-specific chest model for exclusion. On the remaining image, the chest wall muscle was identified and excluded to obtain clean breast segmentation. The chest and muscle boundaries determined on the middle slice were used as the reference for the segmentation of adjacent slices, and the process continued superiorly and inferiorly until all 3D slices were segmented. The segmentation results were evaluated by an experienced radiologist to mark voxels that were wrongly included or excluded for error analysis. Results: The breast volumes measured by the proposed algorithm were very close to the radiologist's corrected volumes, showing a % difference ranging from 0.01% to 3.04% in 30 tested subjects with a mean of 0.86% ± 0.72%. The total error was calculated by adding the inclusion and the exclusion errors (so they did not cancel each other out), which ranged from 0.05% to 6.75% with a mean of 3.05% ± 1.93%. The fibroglandular tissue segmented within the breast region determined by the algorithm and the radiologist were also very close, showing a % difference ranging from 0.02% to 2.52% with a mean of 1.03% ± 1

  20. Should breast density influence patient selection for breast-conserving surgery?

    Science.gov (United States)

    Kapoor, Nimmi S; Eaton, Anne; King, Tari A; Patil, Sujata; Stempel, Michelle; Morris, Elizabeth; Brogi, Edi; Morrow, Monica

    2013-02-01

    In a previous study of the relationship between breast density and primary tumor features, we observed a higher mastectomy rate in patients with extremely dense breasts. Here we examine possible reasons for this finding. Data were obtained from a prospectively maintained database of 1,056 invasive breast cancer patients from January 2005 to June 2007. Mammographic density was assigned by Breast Imaging-Reporting and Data System (BI-RADS) classification. Initial and final surgical procedures, and patient and tumor variables were recorded. Breast-conserving surgery (BCS) was attempted in 758 patients (72 %), 385 (51 %) of whom had preoperative magnetic resonance imaging (MRI). Initial BCS was less common among patients with the highest (BI-RADS 4) breast density compared to patients with less-dense breasts (52 vs. 74 %; p mastectomy compared to patients with less-dense breasts. After initial BCS, 387 patients (51 %) had positive shaved margins, 96 (25 %) of whom converted to mastectomy. MRI did not correlate with the rate of positive margins overall or among those with dense breasts. Adjusting for clinical and pathologic variables, density did not predict margin status or conversion to mastectomy. In a multivariate model, age, histologic grade, extensive intraductal component, and multicentricity/multifocality were independently associated with conversion to mastectomy. Density alone seems to influence the decision to proceed with initial mastectomy. When BCS was attempted, breast density was not associated with positive margins or conversion to mastectomy. A benefit of MRI in decreasing positive margins was not observed. These data do not support the use of breast density as a selection criterion for BCS.

  1. Using deep learning to segment breast and fibroglandular tissue in MRI volumes.

    Science.gov (United States)

    Dalmış, Mehmet Ufuk; Litjens, Geert; Holland, Katharina; Setio, Arnaud; Mann, Ritse; Karssemeijer, Nico; Gubern-Mérida, Albert

    2017-02-01

    Automated segmentation of breast and fibroglandular tissue (FGT) is required for various computer-aided applications of breast MRI. Traditional image analysis and computer vision techniques, such atlas, template matching, or, edge and surface detection, have been applied to solve this task. However, applicability of these methods is usually limited by the characteristics of the images used in the study datasets, while breast MRI varies with respect to the different MRI protocols used, in addition to the variability in breast shapes. All this variability, in addition to various MRI artifacts, makes it a challenging task to develop a robust breast and FGT segmentation method using traditional approaches. Therefore, in this study, we investigated the use of a deep-learning approach known as "U-net." We used a dataset of 66 breast MRI's randomly selected from our scientific archive, which includes five different MRI acquisition protocols and breasts from four breast density categories in a balanced distribution. To prepare reference segmentations, we manually segmented breast and FGT for all images using an in-house developed workstation. We experimented with the application of U-net in two different ways for breast and FGT segmentation. In the first method, following the same pipeline used in traditional approaches, we trained two consecutive (2C) U-nets: first for segmenting the breast in the whole MRI volume and the second for segmenting FGT inside the segmented breast. In the second method, we used a single 3-class (3C) U-net, which performs both tasks simultaneously by segmenting the volume into three regions: nonbreast, fat inside the breast, and FGT inside the breast. For comparison, we applied two existing and published methods to our dataset: an atlas-based method and a sheetness-based method. We used Dice Similarity Coefficient (DSC) to measure the performances of the automated methods, with respect to the manual segmentations. Additionally, we computed

  2. Quantitative assessment of breast density: comparison of different methods

    International Nuclear Information System (INIS)

    Qin Naishan; Guo Li; Dang Yi; Song Luxin; Wang Xiaoying

    2011-01-01

    Objective: To Compare different methods of quantitative breast density measurement. Methods: The study included sixty patients who underwent both mammography and breast MRI. The breast density was computed automatically on digital mammograms with R2 workstation, Two experienced radiologists read the mammograms and assessed the breast density with Wolfe and ACR classification respectively. Fuzzy C-means clustering algorithm (FCM) was used to assess breast density on MRI. Each assessment method was repeated after 2 weeks. Spearman and Pearson correlations of inter- and intrareader and intermodality were computed for density estimates. Results: Inter- and intrareader correlation of Wolfe classification were 0.74 and 0.65, and they were 0.74 and 0.82 for ACR classification respectively. Correlation between Wolfe and ACR classification was 0.77. High interreader correlation of 0.98 and intrareader correlation of 0.96 was observed with MR FCM measurement. And the correlation between digital mammograms and MRI was high in the assessment of breast density (r=0.81, P<0.01). Conclusion: High correlation of breast density estimates on digital mammograms and MRI FCM suggested the former could be used as a simple and accurate method. (authors)

  3. The Effect of California's Breast Density Notification Legislation on Breast Cancer Screening.

    Science.gov (United States)

    Chau, Stephanie Lynn; Alabaster, Amy; Luikart, Karin; Brenman, Leslie Manace; Habel, Laurel A

    2017-04-01

    Half of US states mandate women be notified if they have dense breasts on their mammogram, yet guidelines and data on supplemental screening modalities are limited. Breast density (BD) refers to the extent that breast tissue appears radiographically dense on mammograms. High BD reduces the sensitivity of screening mammography and increases breast cancer risk. The aim of this study was to determine the potential impact of California's 2013 BD notification legislation on breast cancer screening patterns. We conducted a cohort study of women aged 40 to 74 years who were members of a large Northern California integrated health plan (approximately 3.9 million members) in 2011-2015. We calculated pre- and post-legislation rates of screening mammography and magnetic resonance imaging (MRI). We also examined whether women with dense breasts (defined as BI-RADS density c or d) had higher MRI rates than women with nondense breasts (defined as BI-RADS density a or b). After adjustment for race/ethnicity, age, body mass index, medical facility, neighborhood median income, and cancer history, there was a relative 6.6% decrease (relative risk [RR] 0.934, confidence interval [CI] 0.92-0.95) in the rate of screening mammography, largely driven by a decrease among women screening MRI, with the greatest increase among the youngest women. In the postlegislation period, women with extremely dense breasts (BI-RADS d) had 2.77 times (CI 1.93-3.95) the odds of a MRI within 9 months of a screening mammogram compared with women with nondense breasts (BI-RADS b). In this setting, MRI rates increased in the postlegislation period. In addition, women with higher BD were more likely to have supplementary MRI. The decrease in mammography rates seen primarily among younger women may have been due to changes in national screening guidelines.

  4. A comparative study of volumetric breast density estimation in digital mammography and magnetic resonance imaging: results from a high-risk population

    Science.gov (United States)

    Kontos, Despina; Xing, Ye; Bakic, Predrag R.; Conant, Emily F.; Maidment, Andrew D. A.

    2010-03-01

    We performed a study to compare methods for volumetric breast density estimation in digital mammography (DM) and magnetic resonance imaging (MRI) for a high-risk population of women. DM and MRI images of the unaffected breast from 32 women with recently detected abnormalities and/or previously diagnosed breast cancer (age range 31-78 yrs, mean 50.3 yrs) were retrospectively analyzed. DM images were analyzed using QuantraTM (Hologic Inc). The MRI images were analyzed using a fuzzy-C-means segmentation algorithm on the T1 map. Both methods were compared to Cumulus (Univ. Toronto). Volumetric breast density estimates from DM and MRI are highly correlated (r=0.90, pwomen with very low-density breasts (peffects in MRI and differences in the computational aspects of the image analysis methods in MRI and DM. The good correlation between the volumetric and the area-based measures, shown to correlate with breast cancer risk, suggests that both DM and MRI volumetric breast density measures can aid in breast cancer risk assessment. Further work is underway to fully-investigate the association between volumetric breast density measures and breast cancer risk.

  5. Volume based DCE-MRI breast cancer detection with 3D visualization system

    International Nuclear Information System (INIS)

    Chia, F.K.; Sim, K.S.; Chong, S.S.; Tan, S.T.; Ting, H.Y.; Abbas, S.F.; Omar, S.

    2011-01-01

    In this paper, a computer aided design auto probing system is presented to detect breast lesions based on Dynamic contrast enhanced Magnetic resonance imaging (DCE-MRI) images. The system is proposed in order to aid the radiologists and doctors in the interpretation of MRI breast images and enhance the detection accuracy. A series of approaches are presented to enhance the detection accuracy and refine the breast region of interest (Roil) automatically. Besides, a semi-quantitative analysis is used to segment the breast lesions from selected breast Roil and classify the detected tumour is whether benign, suspicious or malignant. The entire breast Roil including the detected tumour will display in 3D. The methodology has been applied on 104 sets of digital imaging and communications in medicine (Dico) breast MRI datasets images. The biopsy results are verified by 2 radiologists from Hospital Malaysia. The experimental results are demonstrated the proposed scheme can precisely identify breast cancer regions with 93% accuracy. (author)

  6. Bilateral symmetry analysis of breast MRI

    International Nuclear Information System (INIS)

    Alterson, Robert; Plewes, Donald B

    2003-01-01

    Mammographic interpretation often uses symmetry between left and right breasts to indicate the site of potential tumour masses. This approach has not been applied to breast images obtained from MRI. We present an automatic technique for breast symmetry detection based on feature extraction techniques which does not require any efforts to co-register breast MRI data. The approach applies computer-vision techniques to detect natural biological symmetries in breast MR scans based on three objective measures of similarity: multiresolution non-orthogonal wavelet representation, three-dimensional intensity distributions and co-occurrence matrices. Statistical distributions that are invariant to feature localization are computed for each of the extracted image features. These distributions are later compared against each other to account for perceptual similarity. Studies based on 51 normal MRI scans of randomly selected patients showed that the sensitivity of symmetry detection rate approached 94%. The symmetry analysis procedure presented in this paper can be applied as an aid in detecting breast tissue changes arising from disease

  7. Breast MRI used as a problem-solving tool reliably excludes malignancy

    International Nuclear Information System (INIS)

    Spick, Claudio; Szolar, Dieter H.M.; Preidler, Klaus W.; Tillich, Manfred; Reittner, Pia; Baltzer, Pascal A.

    2015-01-01

    Highlights: • Breast MRI reliably excludes malignancy in conventional BI-RADS 0 cases (NPV: 100%). • Malignancy rate in the BI-RADS 0 population is substantial with 13.5%. • Breast MRI used as a problem-solving tool reliably excludes malignancy. - Abstract: Purpose: To evaluate the diagnostic performance of breast MRI if used as a problem-solving tool in BI-RADS 0 cases. Material and methods: In this IRB-approved, single-center study, 687 women underwent high-resolution-3D, dynamic contrast-enhanced breast magnetic resonance imaging (MRI) between January 2012 and December 2012. Of these, we analyzed 111 consecutive patients (mean age, 51 ± 12 years; range, 20–83 years) categorized as BI-RADS 0. Breast MRI findings were stratified by clinical presentations, conventional imaging findings, and breast density. MRI results were compared to the reference standard, defined as histopathology or an imaging follow-up of at least 1 year. Results: One hundred eleven patients with BI-RADS 0 conventional imaging findings revealed 30 (27%) mammographic masses, 57 (51.4%) mammographic architectural distortions, five (4.5%) mammographic microcalcifications, 17 (15.3%) ultrasound-only findings, and two palpable findings without imaging correlates. There were 15 true-positive, 85 true-negative, 11 false-positive, and zero false-negative breast MRI findings, resulting in a sensitivity, specificity, PPV, and NPV of 100% (15/15), 88.5% (85/96), 57.7% (15/26), and 100% (85/85), respectively. Breast density and reasons for referral had no significant influence on the diagnostic performance of breast MRI (p > 0.05). Conclusion: Breast MRI reliably excludes malignancy in conventional BI-RADS 0 cases resulting in a NPV of 100% (85/85) and a PPV of 57.7% (15/26)

  8. Background parenchymal enhancement in preoperative breast MRI.

    Science.gov (United States)

    Kohara, Satoko; Ishigaki, Satoko; Satake, Hiroko; Kawamura, Akiko; Kawai, Hisashi; Kikumori, Toyone; Naganawa, Shinji

    2015-08-01

    We aimed to assess the influence of background parenchymal enhancement (BPE) on surgical planning performed using preoperative MRI for breast cancer evaluation. Between January 2009 and December 2010, 91 newly diagnosed breast cancer patients (mean age, 55.5 years; range, 30-88 years) who underwent preoperative bilateral breast MRI followed by planned breast conservation therapy were retrospectively enrolled. MRI was performed to assess the tumor extent in addition to mammography and breast ultrasonography. BPE in the contralateral normal breast MRI at the early dynamic phase was visually classified as follows: minimal (n=49), mild (n=27), moderate (n=7), and marked (n=8). The correlations between the BPE grade and age, menopausal status, index tumor size, changes in surgical management based on MRI results, positive predictive value (PPV) of MRI, and surgical margins were assessed. Patients in the strong BPE groups were significantly younger (p=0.002) and generally premenopausal (p<0.001). Surgical treatment was not changed in 67 cases (73.6%), while extended excision and mastectomy were performed in 12 cases (13.2%), each based on additional lesions on MRI. Six of 79 (7.6%) patients who underwent breast conservation therapy had tumor-positive resection margins. In cases where surgical management was changed, the PPV for MRI-detected foci was high in the minimal (91.7%) and mild groups (66.7%), and 0% in the moderate and marked groups (p=0.002). Strong BPE causes false-positive MRI findings and may lead to overly extensive surgery, whereas MRI may be beneficial in select patients with weak BPE.

  9. Supine breast US: how to correlate breast lesions from prone MRI.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato A; Angelelli, Giuseppe; Moschetta, Marco

    2016-01-01

    To evaluate spatial displacement of breast lesions from prone MR to supine ultrasound positions, and to determine whether the degree of displacement may be associated with breast density and lesion histotype. 380 patients underwent breast MR and second-look ultrasound. The MR and ultrasound lesion location within the breast gland, distances from anatomical landmarks (nipple, skin and pectoral muscle), spatial displacement (distance differences from the landmarks within the same breast region) and region displacement (breast region change) were prospectively evaluated. Differences between MR and ultrasound measurements, association between the degree of spatial displacement and both breast density and lesion histotypes were calculated. In 290/380 (76%) patients, 300 MR lesions were detected. 285/300 (95%) lesions were recognized on ultrasound. By comparing MR and ultrasound, spatial displacement occurred in 183/285 (64.3%) cases while region displacement in 102/285 (35.7%) cases with a circumferential movement along an arc centred on the nipple, having supine ultrasound as the reference standard. A significant association between the degree of lesion displacement and breast density was found (p < 0.00001) with a significant higher displacement in case of fatty breasts. No significant association between the degree of displacement and lesion histotype was found (p = 0.1). Lesion spatial displacement from MRI to ultrasound may occur especially in adipose breasts. Lesion-nipple distance and circumferential displacement from the nipple need to be considered for ultrasound lesion detection. Second-look ultrasound breast lesion detection could be improved by calculating the lesion-nipple distance and considering that spatial displacement from MRI occurs with a circumferential movement along an arc centred on the nipple.

  10. Quantitative Volumetric K-Means Cluster Segmentation of Fibroglandular Tissue and Skin in Breast MRI.

    Science.gov (United States)

    Niukkanen, Anton; Arponen, Otso; Nykänen, Aki; Masarwah, Amro; Sutela, Anna; Liimatainen, Timo; Vanninen, Ritva; Sudah, Mazen

    2017-10-18

    Mammographic breast density (MBD) is the most commonly used method to assess the volume of fibroglandular tissue (FGT). However, MRI could provide a clinically feasible and more accurate alternative. There were three aims in this study: (1) to evaluate a clinically feasible method to quantify FGT with MRI, (2) to assess the inter-rater agreement of MRI-based volumetric measurements and (3) to compare them to measurements acquired using digital mammography and 3D tomosynthesis. This retrospective study examined 72 women (mean age 52.4 ± 12.3 years) with 105 disease-free breasts undergoing diagnostic 3.0-T breast MRI and either digital mammography or tomosynthesis. Two observers analyzed MRI images for breast and FGT volumes and FGT-% from T1-weighted images (0.7-, 2.0-, and 4.0-mm-thick slices) using K-means clustering, data from histogram, and active contour algorithms. Reference values were obtained with Quantra software. Inter-rater agreement for MRI measurements made with 2-mm-thick slices was excellent: for FGT-%, r = 0.994 (95% CI 0.990-0.997); for breast volume, r = 0.985 (95% CI 0.934-0.994); and for FGT volume, r = 0.979 (95% CI 0.958-0.989). MRI-based FGT-% correlated strongly with MBD in mammography (r = 0.819-0.904, P K-means clustering-based assessments of the proportion of the fibroglandular tissue in the breast at MRI are highly reproducible. In the future, quantitative assessment of FGT-% to complement visual estimation of FGT should be performed on a more regular basis as it provides a component which can be incorporated into the individual's breast cancer risk stratification.

  11. Correlativity study on MRI morphologic features, pathology, and molecular biology of breast cancer

    International Nuclear Information System (INIS)

    Chen Rong; Gong Shuigen; Zhang Weiguo; Chen Jinhua; He Shuangwu; Liu Baohua; Li Zengpeng

    2004-01-01

    Objective: To investigate the correlation among MRI morphologic features, pathology, and molecular biology of breast cancer. Methods: MR scanning was performed in 78 patients with breast cancer before operation and MRI morphologic features of breast cancer were analyzed. The mastectomy specimens of the breast neoplasm were stained with immunohistochemistry, and the expression of estrogen receptor (ER), progesterone receptor (PR), C-erbB-2, p53, and the distribution of microvessel density (MVD) was measured. The pathologic results were compared with MRI features. Results: Among the 80 breast cancers, ER positive expression was positively correlated with the spiculate margin of breast cancer (P 0.05). Among the 41 breast cancers with dynamic MR scans, there was positive correlation between the spatial distribution of contrast agent and MVD (P<0.01). Conclusion: There exists some correlation among MRI morphologic features, pathology, and molecular biology factors in breast cancer to certain extent. The biologic behavior and prognosis of the breast cancer can be assessed according to MRI features

  12. Risk-benefit analysis of preoperative breast MRI in patients with primary breast cancer

    International Nuclear Information System (INIS)

    Siegmann, K.C.; Baur, A.; Vogel, U.; Kraemer, B.; Hahn, M.; Claussen, C.D.

    2009-01-01

    Aim: To analyse and compare the risks and benefits of preoperative breast MRI (BMRI) in patients with primary breast cancer (PBC), and to determine the influence of mammographic breast density (BD) and histological tumour type (TT). Materials and Methods: One hundred and nineteen patients who underwent preoperative bilateral breast MRI for staging of PBC during a 1-year period from July 2005 to August 2006 were prospectively evaluated. Changes in clinical management due to BMRI findings were recorded. MRI-detected lesions were correlated with histology. Additional MRI-detected malignant lesions and spared additional biopsies because of negative MRI in case of unclear ultrasound findings were determined as beneficial for the patient. Biopsies of benign MRI detected lesions were defined as disadvantageous. The influence of BD (ACR 1-4) and TT on the change in clinical management and patient benefit was evaluated. Results: The findings of the BMRI examinations changed the clinical management in 48 patients (40.3%). Seventeen women underwent mastectomy instead of breast conservation, eight patients underwent extended excision, 21 additional lesions were clarified by MRI intervention, and two ultrasound-detected lesions were not biopsied because of negative MRI. Histologically malignant additional or extended biopsies (n = 34) and two cases of spared biopsies resulted in 36 (30.3%) women who benefited from preoperative BMRI. Twelve patients (10.1%) had additional biopsies of MRI-detected benign lesions, and therefore, had an unfavourable outcome due to BMRI. The change in clinical management and patient benefit were independent of BD and TT (p > 0.05). Conclusion: Preoperative BMRI was beneficial for 30.3% of 119 patients with PBC. The percentage of additional biopsies of benign lesions (10.1%) seems acceptable

  13. Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Kontos, Despina, E-mail: despina.kontos@uphs.upenn.edu [Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2013-12-15

    Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a

  14. Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

    International Nuclear Information System (INIS)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Kontos, Despina

    2013-01-01

    Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0

  15. Visualization of suspicious lesions in breast MRI based on intelligent neural systems

    Science.gov (United States)

    Twellmann, Thorsten; Lange, Oliver; Nattkemper, Tim Wilhelm; Meyer-Bäse, Anke

    2006-05-01

    Intelligent medical systems based on supervised and unsupervised artificial neural networks are applied to the automatic visualization and classification of suspicious lesions in breast MRI. These systems represent an important component of future sophisticated computer-aided diagnosis systems and enable the extraction of spatial and temporal features of dynamic MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogenity of the cancerous tissue, these techniques reveal the malignant, benign and normal kinetic signals and and provide a regional subclassification of pathological breast tissue. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging.

  16. Fully automated chest wall line segmentation in breast MRI by using context information

    Science.gov (United States)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Localio, A. Russell; Schnall, Mitchell D.; Kontos, Despina

    2012-03-01

    Breast MRI has emerged as an effective modality for the clinical management of breast cancer. Evidence suggests that computer-aided applications can further improve the diagnostic accuracy of breast MRI. A critical and challenging first step for automated breast MRI analysis, is to separate the breast as an organ from the chest wall. Manual segmentation or user-assisted interactive tools are inefficient, tedious, and error-prone, which is prohibitively impractical for processing large amounts of data from clinical trials. To address this challenge, we developed a fully automated and robust computerized segmentation method that intensively utilizes context information of breast MR imaging and the breast tissue's morphological characteristics to accurately delineate the breast and chest wall boundary. A critical component is the joint application of anisotropic diffusion and bilateral image filtering to enhance the edge that corresponds to the chest wall line (CWL) and to reduce the effect of adjacent non-CWL tissues. A CWL voting algorithm is proposed based on CWL candidates yielded from multiple sequential MRI slices, in which a CWL representative is generated and used through a dynamic time warping (DTW) algorithm to filter out inferior candidates, leaving the optimal one. Our method is validated by a representative dataset of 20 3D unilateral breast MRI scans that span the full range of the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) fibroglandular density categorization. A promising performance (average overlay percentage of 89.33%) is observed when the automated segmentation is compared to manually segmented ground truth obtained by an experienced breast imaging radiologist. The automated method runs time-efficiently at ~3 minutes for each breast MR image set (28 slices).

  17. Comparison between breast MRI and contrast-enhanced spectral mammography.

    Science.gov (United States)

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-05-12

    The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.

  18. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  19. Mammography density estimation with automated volumetic breast density measurement

    International Nuclear Information System (INIS)

    Ko, Su Yeon; Kim, Eun Kyung; Kim, Min Jung; Moon, Hee Jung

    2014-01-01

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  20. Automatic Estimation of Volumetric Breast Density Using Artificial Neural Network-Based Calibration of Full-Field Digital Mammography: Feasibility on Japanese Women With and Without Breast Cancer.

    Science.gov (United States)

    Wang, Jeff; Kato, Fumi; Yamashita, Hiroko; Baba, Motoi; Cui, Yi; Li, Ruijiang; Oyama-Manabe, Noriko; Shirato, Hiroki

    2017-04-01

    Breast cancer is the most common invasive cancer among women and its incidence is increasing. Risk assessment is valuable and recent methods are incorporating novel biomarkers such as mammographic density. Artificial neural networks (ANN) are adaptive algorithms capable of performing pattern-to-pattern learning and are well suited for medical applications. They are potentially useful for calibrating full-field digital mammography (FFDM) for quantitative analysis. This study uses ANN modeling to estimate volumetric breast density (VBD) from FFDM on Japanese women with and without breast cancer. ANN calibration of VBD was performed using phantom data for one FFDM system. Mammograms of 46 Japanese women diagnosed with invasive carcinoma and 53 with negative findings were analyzed using ANN models learned. ANN-estimated VBD was validated against phantom data, compared intra-patient, with qualitative composition scoring, with MRI VBD, and inter-patient with classical risk factors of breast cancer as well as cancer status. Phantom validations reached an R 2 of 0.993. Intra-patient validations ranged from R 2 of 0.789 with VBD to 0.908 with breast volume. ANN VBD agreed well with BI-RADS scoring and MRI VBD with R 2 ranging from 0.665 with VBD to 0.852 with breast volume. VBD was significantly higher in women with cancer. Associations with age, BMI, menopause, and cancer status previously reported were also confirmed. ANN modeling appears to produce reasonable measures of mammographic density validated with phantoms, with existing measures of breast density, and with classical biomarkers of breast cancer. FFDM VBD is significantly higher in Japanese women with cancer.

  1. The potential of multiparametric MRI of the breast

    Science.gov (United States)

    Pinker, Katja; Helbich, Thomas H

    2017-01-01

    MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5–7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer. PMID:27805423

  2. MRI of the Breast

    Science.gov (United States)

    ... in evaluating women at high risk for breast cancer. MRI can successfully image the dense breast tissue common in younger women, and it can successfully image breast implants. Both of these are difficult to image using ...

  3. Usefulness of breast-specific gamma imaging as an adjunct modality in breast cancer patients with dense breast. A comparative study with MRI

    International Nuclear Information System (INIS)

    Kim, Bom Sahn

    2012-01-01

    The aim of this study was to evaluate the adjunctive benefits of breast-specific gamma imaging (BSGI) versus magnetic resonance imaging (MRI) in breast cancer patients with dense breasts. This study included a total of 66 patients (44.1±8.2 years) with dense breasts (breast density >50%) and already biopsy-confirmed breast cancer. All of the patients underwent BSGI and MRI as part of an adjunct modality before the initial therapy. Of 66 patients, the 97 undetermined breast lesions were newly detected and correlated with the biopsy results. Twenty-six of the 97 breast lesions proved to be malignant tumors (invasive ductal cancer, n=16; ductal carcinoma in situ, n=6; mixed or other malignancies, n=4); the remaining 71 lesions were diagnosed as benign tumors. The sensitivity and specificity of BSGI were 88.8% (confidence interval (CI), 69.8-97.6%) and 90.1% (CI, 80.7-95.9%), respectively, while the sensitivity and specificity of MRI were 92.3% (CI, 74.9-99.1%) and 39.4% (CI, 28.0-51.7%), respectively (p<0.0001). MRI detected 43 false-positive breast lesions, 37 (86.0%) of which were correctly diagnosed as benign lesions using BSGI. In 12 malignant lesions <1 cm, the sensitivities of BSGI and MR imaging were 83.3% (CI, 51.6-97.9%) and 91.7% (CI, 61.5-99.8%), respectively. BSGI showed an equivocal sensitivity and a high specificity compared to MRI in the diagnosis of breast lesions. In addition, BSGI had a good sensitivity in discriminating breast cancers ≤1 cm. The results of this study suggest that BSGI could play a crucial role as an adjunctive imaging modality which can be used to evaluate breast cancer patients with dense breasts. (author)

  4. Preoperative axillary lymph node evaluation in breast cancer patients by breast magnetic resonance imaging (MRI): Can breast MRI exclude advanced nodal disease?

    International Nuclear Information System (INIS)

    Hyun, Su Jeong; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Kim, Min Jung

    2016-01-01

    To evaluate the diagnostic performance of breast magnetic resonance imaging (MRI) in preoperative evaluation of axillary lymph node metastasis (ALNM) in breast cancer patients and to assess whether breast MRI can be used to exclude advanced nodal disease. A total of 425 patients were included in this study and breast MRI findings were retrospectively reviewed. The diagnostic performance of breast MRI for diagnosis of ALNM was evaluated in all patients, patients with neoadjuvant chemotherapy (NAC), and those without NAC (no-NAC). We evaluated whether negative MRI findings (cN0) can exclude advanced nodal disease (pN2-pN3) using the negative predictive value (NPV) in each group. The sensitivity and NPV of breast MRI in evaluation of ALNM was 51.3 % (60/117) and 83.3 % (284/341), respectively. For cN0 cases on MRI, pN2-pN3 manifested in 1.8 % (6/341) of the overall patients, 0.4 % (1/257) of the no-NAC group, and 6 % (5/84) of the NAC group. The NPV of negative MRI findings for exclusion of pN2-pN3 was higher for the no-NAC group than for the NAC group (99.6 % vs. 94.0 %, p = 0.039). Negative MRI findings (cN0) can exclude the presence of advanced nodal disease with an NPV of 99.6 % in the no-NAC group. (orig.)

  5. Preoperative axillary lymph node evaluation in breast cancer patients by breast magnetic resonance imaging (MRI): Can breast MRI exclude advanced nodal disease?

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Su Jeong [Yonsei University College of Medicine, Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Seoul (Korea, Republic of); Hallym University Medical Center, Department of Radiology, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Kim, Min Jung [Yonsei University College of Medicine, Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the diagnostic performance of breast magnetic resonance imaging (MRI) in preoperative evaluation of axillary lymph node metastasis (ALNM) in breast cancer patients and to assess whether breast MRI can be used to exclude advanced nodal disease. A total of 425 patients were included in this study and breast MRI findings were retrospectively reviewed. The diagnostic performance of breast MRI for diagnosis of ALNM was evaluated in all patients, patients with neoadjuvant chemotherapy (NAC), and those without NAC (no-NAC). We evaluated whether negative MRI findings (cN0) can exclude advanced nodal disease (pN2-pN3) using the negative predictive value (NPV) in each group. The sensitivity and NPV of breast MRI in evaluation of ALNM was 51.3 % (60/117) and 83.3 % (284/341), respectively. For cN0 cases on MRI, pN2-pN3 manifested in 1.8 % (6/341) of the overall patients, 0.4 % (1/257) of the no-NAC group, and 6 % (5/84) of the NAC group. The NPV of negative MRI findings for exclusion of pN2-pN3 was higher for the no-NAC group than for the NAC group (99.6 % vs. 94.0 %, p = 0.039). Negative MRI findings (cN0) can exclude the presence of advanced nodal disease with an NPV of 99.6 % in the no-NAC group. (orig.)

  6. MRI evaluation of the contralateral breast in patients with recently diagnosed breast cancer

    International Nuclear Information System (INIS)

    Taneja, Sangeeta; Jena, Amarnath; Zaidi, Syed Mohd. Shuaib; Khurana, Anuj

    2012-01-01

    Contralateral breast cancer can be synchronous and/or metachronous in patients with cancer of one breast. Detection of a synchronous breast cancer may affect patient management. Dynamic contrast-enhanced MRI of the breast (DCE-MRI) is a sensitive technique for detecting contralateral lesions occult on the other imaging modalities in women already diagnosed with cancer of one breast. The aim was to assess the incidence of mammographically occult synchronous contralateral breast cancer in patients undergoing MRI mammography for the evaluation of a malignant breast lesion. A total of 294 patients with recently diagnosed breast cancer who underwent MRI of the breast were evaluated for lesions in the opposite breast. The incidence of synchronous contralateral malignancy detected by preoperative MRI mammography done for evaluation of extent of disease was 4.1%. Preoperative breast MRI may detect clinically and mammographically occult synchronous contralateral cancer, and can help the patient avoid an additional second surgery or a second course of chemotherapy later; also, as theoretically these lesions are smaller, there may be a survival benefit as well

  7. Management of breast lesions detectable only on MRI

    International Nuclear Information System (INIS)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D.

    2014-01-01

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  8. 3D MRI for Quantitative Analysis of Quadrant Percent Breast Density: Correlation with Quadrant Location of Breast Cancer.

    Science.gov (United States)

    Chen, Jeon-Hor; Liao, Fuyi; Zhang, Yang; Li, Yifan; Chang, Chia-Ju; Chou, Chen-Pin; Yang, Tsung-Lung; Su, Min-Ying

    2017-07-01

    Breast cancer occurs more frequently in the upper outer (UO) quadrant, but whether this higher cancer incidence is related to the greater amount of dense tissue is not known. Magnetic resonance imaging acquires three-dimensional volumetric images and is the most suitable among all breast imaging modalities for regional quantification of density. This study applied a magnetic resonance imaging-based method to measure quadrant percent density (QPD), and evaluated its association with the quadrant location of the developed breast cancer. A total of 126 cases with pathologically confirmed breast cancer were reviewed. Only women who had unilateral breast cancer located in a clear quadrant were selected for analysis. A total of 84 women, including 47 Asian women and 37 western women, were included. An established computer-aided method was used to segment the diseased breast and the contralateral normal breast, and to separate the dense and fatty tissues. Then, a breast was further separated into four quadrants using the nipple and the centroid as anatomic landmarks. The tumor was segmented using a computer-aided method to determine its quadrant location. The distribution of cancer quadrant location, the quadrant with the highest QPD, and the proportion of cancers occurring in the highest QPD were analyzed. The highest incidence of cancer occurred in the UO quadrant (36 out of 84, 42.9%). The highest QPD was also noted most frequently in the UO quadrant (31 out of 84, 36.9%). When correlating the highest QPD with the quadrant location of breast cancer, only 17 women out of 84 (20.2%) had breast cancer occurring in the quadrant with the highest QPD. The results showed that the development of breast cancer in a specific quadrant could not be explained by the density in that quadrant, and further studies are needed to find the biological reasons accounting for the higher breast cancer incidence in the UO quadrant. Copyright © 2017 The Association of University Radiologists

  9. Diagnosis of breast cancer at dynamic MRI in patients with breast augmentation by paraffin or silicone injection

    International Nuclear Information System (INIS)

    Youk, J.H.; Son, E.J.; Kim, E.-K.; Kim, J.-A.; Kim, M.J.; Kwak, J.Y.; Lee, S.M.

    2009-01-01

    Aim: To determine the diagnostic performance of dynamic magnetic resonance imaging (MRI) for breast cancer in breasts augmented with liquid paraffin or silicone injection. Materials and methods: Among 62 patients with breast augmentation by liquid paraffin or silicone injection who had undergone dynamic breast MRI at our institution, 27 women, who had pathological diagnosis or at least 1-year MRI follow-up, were included in this retrospective study and their MRI images were reviewed. For enhancing lesions on MRI, the morphological features, enhancement kinetics, and BI-RADS assessment category were analysed. The lesion characteristics at MRI were correlated with the final diagnosis based on the histopathological result or at least 1-year MRI follow-up. Results: Of the 27 patients, 17 enhancing lesions in 13 patients were found on MRI. All six lesions that were confirmed as malignancy showed suspicious morphological findings and type 2 or 3 enhancement kinetics, assigned to BI-RADS category 4 or 5. Of the remaining 11 benign lesions, 10 showed benign-favouring morphological findings, and all showed type 1 enhancement kinetics, assigned to BI-RADS category 2 or 4. Conclusion: In patients with breasts injected with foreign material, MRI was used to successfully diagnose malignant breast lesions and could be the diagnostic method of choice. Analysis of the morphological and kinetic features at MRI in conjunction with clinical findings is essential.

  10. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  11. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Wesseling, Jelle; Pijnappel, Ruud M.; Rutgers, Emiel J.Th.; Gilhuijs, Kenneth G.A.

    2014-01-01

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  12. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer.

    Science.gov (United States)

    Roganovic, Dragana; Djilas, Dragana; Vujnovic, Sasa; Pavic, Dag; Stojanov, Dragan

    2015-11-16

    Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI), digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities. We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS) was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC) curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p tomosynthesis and breast MRI was not significant (p=0.20).

  13. Analysing breast tissue composition with MRI using currently available short, simple sequences

    International Nuclear Information System (INIS)

    Chau, A.C.M.; Hua, J.; Taylor, D.B.

    2016-01-01

    Aim: To determine the most robust commonly available magnetic resonance imaging (MRI) sequence to quantify breast tissue composition at 1.5 T. Materials and methods: Two-dimensional (2D) T1-weighted, Dixon fat, Dixon water and SPAIR images were obtained from five participants and a breast phantom using a 1.5 T Siemens Aera MRI system. Manual segmentation of the breasts was performed, and an in-house computer program was used to generate signal intensity histograms. Relative trough depth and relative peak separation were used to determine the robustness of the images for quantifying the two breast tissues. Total breast volumes and percentage breast densities calculated using the four sequences were compared. Results: Dixon fat histograms had consistently low relative trough depth and relative peak separation compared to those obtained using other sequences. There was no significant difference in total breast volumes and percentage breast densities of the participants or breast phantom using Dixon fat and 2D T1-weighted histograms. Dixon water and SPAIR histograms were not suitable for quantifying breast tissue composition. Conclusion: Dixon fat images are the most robust for the quantification of breast tissue composition using a signal intensity histogram. - Highlights: • Signal intensity histogram analysis can determine robustness of images for quantification of breast tissue composition. • Dixon fat images are the most robust. • The characteristics of the signal intensity histograms from Dixon water and SPAIR images make quantification unsuitable.

  14. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Dragana Roganovic

    2015-11-01

    Full Text Available Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI, digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities.  We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p < 0.001, while the difference between breast tomosynthesis and breast MRI was not significant (p = 0.20. 

  15. Imaging Breast Density: Established and Emerging Modalities

    Directory of Open Access Journals (Sweden)

    Jeon-Hor Chen

    2015-12-01

    Full Text Available Mammographic density has been proven as an independent risk factor for breast cancer. Women with dense breast tissue visible on a mammogram have a much higher cancer risk than women with little density. A great research effort has been devoted to incorporate breast density into risk prediction models to better estimate each individual’s cancer risk. In recent years, the passage of breast density notification legislation in many states in USA requires that every mammography report should provide information regarding the patient’s breast density. Accurate definition and measurement of breast density are thus important, which may allow all the potential clinical applications of breast density to be implemented. Because the two-dimensional mammography-based measurement is subject to tissue overlapping and thus not able to provide volumetric information, there is an urgent need to develop reliable quantitative measurements of breast density. Various new imaging technologies are being developed. Among these new modalities, volumetric mammographic density methods and three-dimensional magnetic resonance imaging are the most well studied. Besides, emerging modalities, including different x-ray–based, optical imaging, and ultrasound-based methods, have also been investigated. All these modalities may either overcome some fundamental problems related to mammographic density or provide additional density and/or compositional information. The present review article aimed to summarize the current established and emerging imaging techniques for the measurement of breast density and the evidence of the clinical use of these density methods from the literature.

  16. FAST MRI breast screening revisited

    International Nuclear Information System (INIS)

    Jain, Manish; Jain, Arushi; Hyzy, Marek D.; Werth, Graziella

    2017-01-01

    Screening for breast cancer in high-risk women takes about 40 minutes to acquire an MRI scan and is time-intensive to report. There is recent interest in the performance of an abbreviated MRI protocol (FAST) in the screening setting. FAST scans have a reported negative predictive value of 99.8%. This study evaluates the false positive rates (FPR) and recall rates for FAST scans as compared to full diagnostic studies (FD). A database of all screening breast MRI scans performed at our institution between 30 June 2013 and 1 July 2014 (n = 591) was created by one of the researchers, who did not subsequently analyse the MRI scans. The T1W and first post-contrast and subtracted images from each of these scans (FAST protocol) were assessed by experienced breast MRI radiologists, blinded to the final diagnosis. The findings were then compared with the FD result. The recall rates were 6.6% for FAST scans and 5.8% for FD scans. FPR rates were 4.7% and 3.9% respectively. There is no statistically significant difference in the recall rates or FPR of FAST scans in comparison with full diagnostic studies. Given the absence of statistically significant difference in the FPR and recall rates in comparison with FD, FAST scans can replace FD for screening of breast cancer.

  17. The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer

    International Nuclear Information System (INIS)

    Fischer, Uwe; Baum, Friedemann; Heyden, Dorit von; Zachariae, Olivier; Liersch, Torsten; Funke, Matthias

    2004-01-01

    Preoperative MRI of the breasts has been proven to be the most sensitive imaging modality in the detection of multifocal or multicentric tumor manifestations as well as simultaneous contralateral breast cancer. The aim of the presented retrospective study was to evaluate the benefit of preoperative MRI for patients with breast cancer. Preoperative MRI performed in 121 patients (group A) were compared to 225 patients without preoperative MRI (group B). Patients of group A underwent contrast-enhanced MR imaging of the breast using a 2D FLASH sequence technique (TR/TE/FA 336 ms/5 ms/90diam.; 32 slices of 4-mm thickness, time of acquisition 1:27 min, contrast agent dosage 0.1 mmol Gd-DTPA/kg bw). All patients had histologically verified breast cancer and follow-up for more than 20 months (mean time group A: 40.3 months, group B: 41 months). Both groups received the same types of systemic treatment after breast conserving surgery. The in-breast tumor recurrence rate in group A was 1/86 (1.2%) compared to 9/133 (6.8%) in group B. Contralateral carcinoma were detected within follow-up in 2/121 (1.7%) in group A vs. 9/225 (4%) in group B. All results were statistically significant (P<0.001). Based on these results, preoperative MRI of the breasts is recommended in patients with histopathologically verified breast cancer for local staging

  18. The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann; Heyden, Dorit von [Diagnostisches Brustzentrum Goettingen, Womens Health Care Center Goettingen, Bahnhofsallee 1d, 37081 Goettingen (Germany); Zachariae, Olivier; Liersch, Torsten [Department of General Surgery, Georg-August-University of Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany); Funke, Matthias [Department of Radiology, Georg-August-University of Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2004-10-01

    Preoperative MRI of the breasts has been proven to be the most sensitive imaging modality in the detection of multifocal or multicentric tumor manifestations as well as simultaneous contralateral breast cancer. The aim of the presented retrospective study was to evaluate the benefit of preoperative MRI for patients with breast cancer. Preoperative MRI performed in 121 patients (group A) were compared to 225 patients without preoperative MRI (group B). Patients of group A underwent contrast-enhanced MR imaging of the breast using a 2D FLASH sequence technique (TR/TE/FA 336 ms/5 ms/90{sup o}; 32 slices of 4-mm thickness, time of acquisition 1:27 min, contrast agent dosage 0.1 mmol Gd-DTPA/kg bw). All patients had histologically verified breast cancer and follow-up for more than 20 months (mean time group A: 40.3 months, group B: 41 months). Both groups received the same types of systemic treatment after breast conserving surgery. The in-breast tumor recurrence rate in group A was 1/86 (1.2%) compared to 9/133 (6.8%) in group B. Contralateral carcinoma were detected within follow-up in 2/121 (1.7%) in group A vs. 9/225 (4%) in group B. All results were statistically significant (P<0.001). Based on these results, preoperative MRI of the breasts is recommended in patients with histopathologically verified breast cancer for local staging.

  19. Breast MRI: EUSOBI recommendations for women's information

    International Nuclear Information System (INIS)

    Mann, Ritse M.; Balleyguier, Corinne; Baltzer, Pascal A.; Helbich, Thomas H.; Pinker-Domenig, Katja; Bick, Ulrich; Fallenberg, Eva; Colin, Catherine; Cornford, Eleanor; Evans, Andrew; Forrai, Gabor; Fuchsjaeger, Michael H.; Gilbert, Fiona J.; Heywang-Koebrunner, Sylvia H.; Camps-Herrero, Julia; Kuhl, Christiane K.; Martincich, Laura; Pediconi, Federica; Panizza, Pietro; Pina, Luis J.; Pijnappel, Ruud M.; Skaane, Per; Sardanelli, Francesco

    2015-01-01

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS registered categories and further actions after a breast MRI examination are discussed. Breast MRI is a very sensitive modality, significantly improving screening in high-risk women. It also has a role in clinical diagnosis, problem solving, and staging, impacting on patient management. However, it is not a perfect test, and occasionally breast cancers can be missed. Therefore, clinical and other imaging findings (from mammography/ultrasound) should also be considered. Conversely, MRI may detect lesions not visible on other imaging modalities turning out to be benign (false positives). These risks should be discussed with women before a breast MRI is requested/performed. Because breast MRI drawbacks depend upon the indication for the examination, basic information for the most important breast MRI indications is presented. Seventeen notes and five frequently asked questions formulated for use as direct communication to women are provided. The text was reviewed by Europa Donna-The European Breast Cancer Coalition to ensure that it can be easily understood by women undergoing MRI. (orig.)

  20. Breast MRI: EUSOBI recommendations for women's information

    Energy Technology Data Exchange (ETDEWEB)

    Mann, Ritse M. [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Balleyguier, Corinne [Gustave-Roussy Institute, Department of Radiology, Villejuif (France); Baltzer, Pascal A.; Helbich, Thomas H.; Pinker-Domenig, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Bick, Ulrich; Fallenberg, Eva [Universitaetsmedizin Berlin, Clinic of Radiology, Charite, Berlin (Germany); Colin, Catherine [Centre Hospitalo-Universitaire Lyon Sud, Radiology Unit, Hospices Civils de Lyon, Pierre Benite Cedex (France); Cornford, Eleanor [Nottingham University Hospitals, Nottingham Breast Institute, Nottingham (United Kingdom); Evans, Andrew [Ninewells Hospital and Medical School, Dundee Cancer Centre, Clinical Research Centre, Dundee (United Kingdom); Forrai, Gabor [MHEK Teaching Hospital University Semmelweis, Budapest (Hungary); Fuchsjaeger, Michael H. [Medical University of Graz, Department of Radiology, Graz (Austria); Gilbert, Fiona J. [University of Cambridge, School of Clinical Medicine, Department of Radiology, Cambridge (United Kingdom); Heywang-Koebrunner, Sylvia H. [National Reference Centre Mammography, Munich, Munich (Germany); Camps-Herrero, Julia [Hospital de la Ribera, Department of Radiology, Alzira, Valencia (Spain); Kuhl, Christiane K. [University Hospital of Aachen, Rheinisch-Westfaelische Technische Hochschule, Aachen (Germany); Martincich, Laura [IRCCS-FPO, Radiology Unit, Candiolo, Turin (Italy); Pediconi, Federica [Sapienza University, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Panizza, Pietro [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Radiology 1, Milan (Italy); Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona, Navarra (Spain); Pijnappel, Ruud M. [University Medical Centre Utrecht, Department of Imaging, Utrecht (Netherlands); Skaane, Per [Oslo University Hospital Ullevaal, University of Oslo, Department of Radiology, Oslo (Norway); Sardanelli, Francesco [Universita degli Studi di Milano, Radiology Unit, IRCCS Policlinico San Donato, Department of Biomedical Sciences for Health, San Donato Milanese, Milan (Italy); Collaboration: for the European Society of Breast Imaging (EUSOBI), with language review by Europa Donna-The European Breast Cancer Coalition

    2015-12-15

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS registered categories and further actions after a breast MRI examination are discussed. Breast MRI is a very sensitive modality, significantly improving screening in high-risk women. It also has a role in clinical diagnosis, problem solving, and staging, impacting on patient management. However, it is not a perfect test, and occasionally breast cancers can be missed. Therefore, clinical and other imaging findings (from mammography/ultrasound) should also be considered. Conversely, MRI may detect lesions not visible on other imaging modalities turning out to be benign (false positives). These risks should be discussed with women before a breast MRI is requested/performed. Because breast MRI drawbacks depend upon the indication for the examination, basic information for the most important breast MRI indications is presented. Seventeen notes and five frequently asked questions formulated for use as direct communication to women are provided. The text was reviewed by Europa Donna-The European Breast Cancer Coalition to ensure that it can be easily understood by women undergoing MRI. (orig.)

  1. Relationship between preoperative breast MRI and surgical treatment of non-metastatic breast cancer.

    Science.gov (United States)

    Onega, Tracy; Weiss, Julie E; Goodrich, Martha E; Zhu, Weiwei; DeMartini, Wendy B; Kerlikowske, Karla; Ozanne, Elissa; Tosteson, Anna N A; Henderson, Louise M; Buist, Diana S M; Wernli, Karen J; Herschorn, Sally D; Hotaling, Elise; O'Donoghue, Cristina; Hubbard, Rebecca

    2017-12-01

    More extensive surgical treatments for early stage breast cancer are increasing. The patterns of preoperative MRI overall and by stage for this trend has not been well established. Using Breast Cancer Surveillance Consortium registry data from 2010 through 2014, we identified women with an incident non-metastatic breast cancer and determined use of preoperative MRI and initial surgical treatment (mastectomy, with or without contralateral prophylactic mastectomy (CPM), reconstruction, and breast conserving surgery ± radiation). Clinical and sociodemographic covariates were included in multivariable logistic regression models to estimate adjusted odds ratios and 95% confidence intervals. Of the 13 097 women, 2217 (16.9%) had a preoperative MRI. Among the women with MRI, results indicated 32% higher odds of unilateral mastectomy compared to breast conserving surgery and of mastectomy with CPM compared to unilateral mastectomy. Women with preoperative MRI also had 56% higher odds of reconstruction. Preoperative MRI in women with DCIS and early stage invasive breast cancer is associated with more frequent mastectomy, CPM, and reconstruction surgical treatment. Use of more extensive surgical treatment and reconstruction among women with DCIS and early stage invasive cancer whom undergo MRI warrants further investigation. © 2017 Wiley Periodicals, Inc.

  2. A Retrospective Study Evaluating the Impact of Preoperative Breast MRI on Surgical Decision-Making in Young Patients (≤50 Years with Invasive Breast Cancer

    Directory of Open Access Journals (Sweden)

    Som D. Mukherjee

    2016-01-01

    Full Text Available Introduction Breast magnetic resonance imaging (MRI is considered a more sensitive diagnostic test for detecting invasive breast cancer than mammography or breast ultrasound. Breast MRI may be particularly useful in younger premenopausal women with higher density breast tissue for differentiating between dense fibroglandular breast tissue and breast malignancies. The main objective of this study was to determine the impact of preoperative breast MRI on surgical decision-making in young women with breast cancer. Methods A retrospective review of patients with newly diagnosed invasive breast cancer and age of ≤50 years was performed. All patients underwent physical examination, preoperative mammogram, breast ultrasound, and bilateral breast MRI. Two breast cancer surgeons reviewed the preoperative mammogram report, breast ultrasound report, and physical examination summary and were asked if they would recommend a lumpectomy, a quandrantectomy, or a mastectomy. A few weeks later, the two surgeons were shown the same information with the breast MRI report and were asked what type of surgery they would now recommend. In each case, MRI was classified by two adjudicators as having affected the surgical outcome in a positive, negative, or neutral fashion. A positive impact was defined as the situation where breast MRI detected additional disease that was not found on physical examination, mammogram, or breast ultrasound and led to an appropriate change in surgical management. A negative impact was defined as the situation where breast MRI led the surgeon to recommend more extensive surgery, with less extensive disease actually found at pathology. No impact was defined as the situation where MRI findings did not alter surgical recommendations or outcomes. Results Of 37 patients whose charts were reviewed, five patients were deemed to be ineligible due to having received neoadjuvant chemotherapy, having previous breast implants, or having had their

  3. Diffuse optical tomography with structured-light patterns to quantify breast density

    Science.gov (United States)

    Kwong, Jessica; Nouizi, Farouk; Cho, Jaedu; Zheng, Jie; Li, Yifan; Chen, Jeon-hor; Su, Min-Ying; Gulsen, Gultekin

    2016-02-01

    Breast density is an independent risk factor for breast cancer, where women with denser breasts are more likely to develop cancer. By identifying women at higher risk, healthcare providers can suggest screening at a younger age to effectively diagnose and treat breast cancer in its earlier stages. Clinical risk assessment models currently do not incorporate breast density, despite its strong correlation with breast cancer. Current methods to measure breast density rely on mammography and MRI, both of which may be difficult to use as a routine risk assessment tool. We propose to use diffuse optical tomography with structured-light to measure the dense, fibroglandular (FGT) tissue volume, which has a different chromophore signature than the surrounding adipose tissue. To test the ability of this technique, we performed simulations by creating numerical breast phantoms from segmented breast MR images. We looked at two different cases, one with a centralized FGT distribution and one with a dispersed distribution. As expected, the water and lipid volumes segmented at half-maximum were overestimated for the dispersed case. However, it was noticed that the recovered water and lipid concentrations were lower and higher, respectively, than the centralized case. This information may provide insight into the morphological distribution of the FGT and can be a correction in estimating the breast density.

  4. Diagnostic value of dynamic and morphologic breast MRI analysis in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Stusińska, Małgorzata; Szabo-Moskal, Jadwiga; Bobek-Billewicz, Barbara

    2014-01-01

    Mammography is the most widely used method of breast imaging. However, its low sensitivity poses a problem. Breast MRI is one of so the called “complementary” breast imaging methods. The purpose of this study was to improve the specificity of breast MRI by combining 2 methods: dynamic and morphologic analysis of enhancing lesions. 222 women aged 19–76 years, who underwent breast MRI examination between November 2002 and April 2004 at the Radiology Department of Oncology Center in Bydgoszcz, were included in this study. The pathological examination revealed cancer in 55 women (25%). No cancer was found in 167 women (75%), 56 of which were verified pathologically, 111 by cytology and/or during follow-up (at least 24 months). Results of breast MRI were positive in 80 women (36%), in 54 of which cancer was found during pathological examination, 26 breast MRI results were false positive. Sensitivity and specificity of breast MRI for dynamic analysis were 87% and 72%, respectively; in case of morphologic analysis 98% and 74%, respectively. The combined dynamic and morphologic analysis achieved high (84%) specificity without loss of sensitivity (98%). The difference in specificity between the evaluated methods was statistically significant (p<0.05). The combined dynamic and morphologic breast MRI analysis is a useful method for the diagnosis of breast cancer

  5. Spectral embedding based active contour (SEAC): application to breast lesion segmentation on DCE-MRI

    Science.gov (United States)

    Agner, Shannon C.; Xu, Jun; Rosen, Mark; Karthigeyan, Sudha; Englander, Sarah; Madabhushi, Anant

    2011-03-01

    Spectral embedding (SE), a graph-based manifold learning method, has previously been shown to be useful in high dimensional data classification. In this work, we present a novel SE based active contour (SEAC) segmentation scheme and demonstrate its applications in lesion segmentation on breast dynamic contrast enhance magnetic resonance imaging (DCE-MRI). In this work, we employ SE on DCE-MRI on a per voxel basis to embed the high dimensional time series intensity vector into a reduced dimensional space, where the reduced embedding space is characterized by the principal eigenvectors. The orthogonal eigenvector-based data representation allows for computation of strong tensor gradients in the spectrally embedded space and also yields improved region statistics that serve as optimal stopping criteria for SEAC. We demonstrate both analytically and empirically that the tensor gradients in the spectrally embedded space are stronger than the corresponding gradients in the original grayscale intensity space. On a total of 50 breast DCE-MRI studies, SEAC yielded a mean absolute difference (MAD) of 3.2+/-2.1 pixels and mean Dice similarity coefficient (DSC) of 0.74+/-0.13 compared to manual ground truth segmentation. An active contour in conjunction with fuzzy c-means (FCM+AC), a commonly used segmentation method for breast DCE-MRI, produced a corresponding MAD of 7.2+/-7.4 pixels and mean DSC of 0.58+/-0.32. In conjunction with a set of 6 quantitative morphological features automatically extracted from the SEAC derived lesion boundary, a support vector machine (SVM) classifier yielded an area under the curve (AUC) of 0.73, for discriminating between 10 benign and 30 malignant lesions; the corresponding SVM classifier with the FCM+AC derived morphological features yielded an AUC of 0.65.

  6. Incidental extra-mammary findings in breast MRI

    International Nuclear Information System (INIS)

    Alduk, A.M.; Prutki, M.; Stern-Padovan, R.

    2015-01-01

    Aim: To investigate the frequency, distribution, and nature of incidental extra-mammary findings detected with breast MRI. Materials and methods: Incidental findings were defined as unexpected lesions outside the breast, not previously known or suspected at the time of referral. Five hundred consecutive breast MRI studies performed from June 2010 to September 2012 were reviewed in this retrospective study for which the institutional review board granted approval and waived the requirement for informed consent. MRI findings were compared with subsequent diagnostic procedures in order to differentiate benign from malignant lesions. Results: One hundred and thirty-eight incidental findings were found in 107 of the 500 (21.4%) examined patients. The most common site was the liver (61/138; 44.2%), followed by the lung (24/138; 17.4%), mediastinum (22/138; 15.9%), pleural cavity (15/138; 10.9%), bone tissue (9/138; 6.5%), spleen (3/138; 2.2%), major pectoral muscle (3/138; 2.2%), and kidney (1/138; 0.7%). Twenty-five of the 138 (18.1%) incidental findings were confirmed to be malignant, whereas the remaining 113 (81.9%) were benign. Malignant findings were exclusively detected in patients with known breast carcinoma, whereas incidental findings in patients without a history of carcinoma were all benign. Twenty-five of 100 (24.8%) incidental findings among patients with history of breast cancer were malignant. Conclusion: Although many of incidental findings were benign, some were malignant, altering the diagnostic work-up, staging, and treatment. Therefore, it is important to assess the entire field of view carefully for abnormalities when reviewing breast MRI studies. - Highlights: • 500 consecutive breast MRI studies were retrospectively reviewed. • Incidental findings were found in 107/500 (21.4%) of examined patients. • Incidental extra-mammary findings on breast MRI are common. • Malignant findings were exclusively detected in patients with known breast

  7. Correlative study of the parameters of dynamic contrast-enhanced MRI and angiogenesis in breast lesions

    International Nuclear Information System (INIS)

    Tang Guangyu; Xiao Xiangsheng; Liu Yong; Yao Yiping; Li Wei; Zhao Wenrong; Li Peng

    2007-01-01

    Objective: To evaluate the relationship between dynamic contrast-enhanced MRI (DCE-MRI)-derived parameters and tumor angiogenesis in malignant and benign breast lesions. Methods: Fifty-one patients with malignant and benign breast lesions underwent DCE-MRI using a Philips Intera 1.5 T MR System and dedicated breast coil prospectively before operation. DCE-MRI derived parameters such as steepest slope (S max )), peak height (PH), time-to-peak (T peak ) were calculated based on time-signal intensity curve. The micro-vessel density (MVD) was counted and vascular endothelial growth factor (VEGF) expression was assessed in these patients after operation with immunohistochemical staining method. The parameters were correlated statistically with MVD counts and VEGF expression in breast cancer. The MVD counts and VEGF expression were also compared among the patients with breast cancer (29 cases), with fibroadenoma (12 cases), mastopathy (10 cases) and the normal tissue (10 cases). Results: The enhancement parameters S max (r=0.807, P peak (69 ± 38) correlated negatively with MVD counts (r=-0.425, P< 0.05). The mean value of MVD (65.09±15.81/200 times field) in patients with breast cancer were significantly higher than those with fibroadenoma, mastopathy or normal tissue (P=0.043, 0.018, 0.002 respectively). 69% (20/29 cases) of breast cancers demonstrated positive VEGF expression, which were significantly more than that of fibroadenoma, mastopathy or normal tissue (P=0.035, 0.007, 0.001 respectively). Moreover, the MVD counts (60.38±24.14) in the peripheral region of breast cancer were more than those in central region (37.64±16.52; t=2.635, P=0.016). There was a significant difference in MVD counts between breast cancers with metastasis to axillary lymph nodes (73.23±23.02) and those without metastasis (59.34±18.03), (t=2.303, P=0.031). Conclusions: Some parameters derived from DCE-MRI correlated positively with MVD counts and VEGF expression in patients with breast

  8. Affinity proteomic profiling of plasma for proteins associated to area-based mammographic breast density.

    Science.gov (United States)

    Byström, Sanna; Eklund, Martin; Hong, Mun-Gwan; Fredolini, Claudia; Eriksson, Mikael; Czene, Kamila; Hall, Per; Schwenk, Jochen M; Gabrielson, Marike

    2018-02-14

    Mammographic breast density is one of the strongest risk factors for breast cancer, but molecular understanding of how breast density relates to cancer risk is less complete. Studies of proteins in blood plasma, possibly associated with mammographic density, are well-suited as these allow large-scale analyses and might shed light on the association between breast cancer and breast density. Plasma samples from 1329 women in the Swedish KARMA project, without prior history of breast cancer, were profiled with antibody suspension bead array (SBA) assays. Two sample sets comprising 729 and 600 women were screened by two different SBAs targeting a total number of 357 proteins. Protein targets were selected through searching the literature, for either being related to breast cancer or for being linked to the extracellular matrix. Association between proteins and absolute area-based breast density (AD) was assessed by quantile regression, adjusting for age and body mass index (BMI). Plasma profiling revealed linear association between 20 proteins and AD, concordant in the two sets of samples (p density and processes of tissue homeostasis, DNA repair, cancer development and/or progression in breast cancer. Further validation and follow-up studies of the shortlisted protein candidates in independent cohorts will be needed to infer their role in breast density and its progression in premenopausal and postmenopausal women.

  9. Comparative analysis of nonlinear dimensionality reduction techniques for breast MRI segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Akhbardeh, Alireza; Jacobs, Michael A. [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205 (United States); Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205 (United States) and Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205 (United States)

    2012-04-15

    Purpose: Visualization of anatomical structures using radiological imaging methods is an important tool in medicine to differentiate normal from pathological tissue and can generate large amounts of data for a radiologist to read. Integrating these large data sets is difficult and time-consuming. A new approach uses both supervised and unsupervised advanced machine learning techniques to visualize and segment radiological data. This study describes the application of a novel hybrid scheme, based on combining wavelet transform and nonlinear dimensionality reduction (NLDR) methods, to breast magnetic resonance imaging (MRI) data using three well-established NLDR techniques, namely, ISOMAP, local linear embedding (LLE), and diffusion maps (DfM), to perform a comparative performance analysis. Methods: Twenty-five breast lesion subjects were scanned using a 3T scanner. MRI sequences used were T1-weighted, T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging. The hybrid scheme consisted of two steps: preprocessing and postprocessing of the data. The preprocessing step was applied for B{sub 1} inhomogeneity correction, image registration, and wavelet-based image compression to match and denoise the data. In the postprocessing step, MRI parameters were considered data dimensions and the NLDR-based hybrid approach was applied to integrate the MRI parameters into a single image, termed the embedded image. This was achieved by mapping all pixel intensities from the higher dimension to a lower dimensional (embedded) space. For validation, the authors compared the hybrid NLDR with linear methods of principal component analysis (PCA) and multidimensional scaling (MDS) using synthetic data. For the clinical application, the authors used breast MRI data, comparison was performed using the postcontrast DCE MRI image and evaluating the congruence of the segmented lesions. Results: The NLDR-based hybrid approach was able to define and segment

  10. Comparative analysis of nonlinear dimensionality reduction techniques for breast MRI segmentation

    International Nuclear Information System (INIS)

    Akhbardeh, Alireza; Jacobs, Michael A.

    2012-01-01

    Purpose: Visualization of anatomical structures using radiological imaging methods is an important tool in medicine to differentiate normal from pathological tissue and can generate large amounts of data for a radiologist to read. Integrating these large data sets is difficult and time-consuming. A new approach uses both supervised and unsupervised advanced machine learning techniques to visualize and segment radiological data. This study describes the application of a novel hybrid scheme, based on combining wavelet transform and nonlinear dimensionality reduction (NLDR) methods, to breast magnetic resonance imaging (MRI) data using three well-established NLDR techniques, namely, ISOMAP, local linear embedding (LLE), and diffusion maps (DfM), to perform a comparative performance analysis. Methods: Twenty-five breast lesion subjects were scanned using a 3T scanner. MRI sequences used were T1-weighted, T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging. The hybrid scheme consisted of two steps: preprocessing and postprocessing of the data. The preprocessing step was applied for B 1 inhomogeneity correction, image registration, and wavelet-based image compression to match and denoise the data. In the postprocessing step, MRI parameters were considered data dimensions and the NLDR-based hybrid approach was applied to integrate the MRI parameters into a single image, termed the embedded image. This was achieved by mapping all pixel intensities from the higher dimension to a lower dimensional (embedded) space. For validation, the authors compared the hybrid NLDR with linear methods of principal component analysis (PCA) and multidimensional scaling (MDS) using synthetic data. For the clinical application, the authors used breast MRI data, comparison was performed using the postcontrast DCE MRI image and evaluating the congruence of the segmented lesions. Results: The NLDR-based hybrid approach was able to define and segment both

  11. Imaging Management of Breast Density, a Controversial Risk Factor for Breast Cancer.

    Science.gov (United States)

    Falcon, Shannon; Williams, Angela; Weinfurtner, Jared; Drukteinis, Jennifer S

    2017-04-01

    Breast density is well recognized as an independent risk factor for the development of breast cancer. However, the magnitude of risk is controversial. As the public becomes increasingly aware of breast density as a risk factor, legislation and notification laws in relation to breast density have become common throughout the United States. Awareness of breast density as a risk factor for breast cancer presents new challenges for the clinician in the approach to the management and screening of women with dense breasts. The evidence and controversy surrounding breast density as a risk factor for the development of breast cancer are discussed. Common supplemental screening modalities for breast cancer are also discussed, including tomosynthesis, ultrasonography, and magnetic resonance imaging. A management strategy for screening women with dense breasts is also presented. The American College of Radiology recognizes breast density as a controversial risk factor for breast cancer, whereas the American Congress of Obstetricians and Gynecologists recognizes breast density as a modest risk factor. Neither organization recommends the routine use of supplemental screening in women with dense breasts without considering additional patient-related risk factors. Breast density is a poorly understood and controversial risk factor for the development of breast cancer. Mammography is a screening modality proven to reduce breast cancer-related mortality rates and is the single most appropriate tool for population-based screening. Use of supplemental screening modalities should be tailored to individual risk assessment.

  12. Quantitative assessment of breast density from mammograms

    International Nuclear Information System (INIS)

    Jamal, N.; Ng, K.H.

    2004-01-01

    Full text: It is known that breast density is increasingly used as a risk factor for breast cancer. This study was undertaken to develop and validate a semi-automated computer technique for the quantitative assessment of breast density from digitised mammograms. A computer technique had been developed using MATLAB (Version 6.1) based GUI applications. This semi-automated image analysis tool consists of gradient correction, segmentation of breast region from background, segmentation of fibroglandular and adipose region within the breast area and calculation of breast density. The density is defined as the percentage of fibroglandular tissue area divided by the total breast area in the mammogram. This technique was clinically validated with 122 normal mammograms; these were subjectively evaluated and classified according to the five parenchyma patterns of the Tabar's scheme (Class I- V) by a consultant radiologist. There was a statistical significant correlation between the computer technique and subjective classification (r 2 = 0.84, p<0.05). 71.3% of subjective classification was correctly classified using the computer technique. We had developed a computer technique for the quantitative assessment of breast density and validated its accuracy for computerized classification based on Tabar's scheme. This quantitative tool is useful for the evaluation of a large dataset of mammograms to predict breast cancer risk based on density. Furthermore it has the potential to provide an early marker for success or failure in chemoprevention studies such as hormonal replacement therapy. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  13. Diagnostic usefulness of segmental and linear enhancement in dynamic breast MRI

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, N.; Leutner, C.; Schild, H.; Traeber, F.; Kuhl, C.

    2005-01-01

    The aim of this study was the evaluation of the diagnostic usefulness of ductal or segmental enhancement in dynamic breast MRI. Segmental and ductal enhancement have been established as the breast MRI hallmarks of intraductal breast cancer (DCIS); however, the positive predictive value of this imaging finding is still unknown. In our study, we analysed the overall prevalence of a segmental or a linear enhancement pattern on breast MRI for an unselected cohort of patients. The aim was to evaluate the diagnostic usefulness of segmental or linear enhancement. Second, we asked whether biopsy was necessary also in the absence of mammographic findings suggestive of DCIS. Prospective, consecutive evaluation of 1,003 patients undergoing bilateral dynamic breast MRI. Studies were interpreted by two experienced breast radiologists. A diagnostic or screening two-view mammogram was available for all patients. Biopsy or short-term breast MRI follow-up was recommended for patients showing a segmental or a linear enhancement pattern on breast MRI. The patients' final diagnoses were established by imaging guided excisional or core biopsy or by clinical plus conventional imaging follow-up for a period of 2 years. The prevalence of segmental or linear enhancement was determined for patients with a final diagnosis of benign breast disease compared with those with a diagnosis of breast cancer. One hundred twenty patients had invasive breast cancer, 24 patients had DCIS and 859 patients had unsuspicious breast MRI or benign breast disease. A segmental or a linear enhancement pattern was found for 50/1,003 (5%) patients (17 DCIS, 33 benign breast diseases). Accordingly, the positive predictive value of segmental and linear enhancement is 34% (17/50); the specificity of this criterion is 96% (826/859). For 4/24 (17%) patients, DCIS was visible as segmental or linear enhancement on dynamic breast MRI, whereas no abnormalities were visible on the corresponding mammogram. The overall

  14. Screening for breast cancer with MRI: recent experience from the Australian Capital Territory

    International Nuclear Information System (INIS)

    Price, J.; Chen, S. W.

    2009-01-01

    Full text: The American Cancer Society now recommends annual MRI screening for women at 20-25% or greater lifetime risk of breast cancer. The role of MRI screening in other risk subgroups is unproved because of insufficient data. Our study comprised 209 breast MRI scans carried out in 171 asymptomatic patients (age range 22-67 years, mean 46 years), referred between January 2005 and June 2008. Targeted ultrasound was carried out in 32 episodes (15%) and biopsies were taken in 23 patients (13%). In four patients, MR-guided procedures were required to establish a diagnosis, two using hook-wire localization and two by means of vacuum-assisted biopsy. Seven cancers were detected by MRI in the 171 patients, with a yield of 4.1%. Only one of the seven cancers was also shown by x-ray mammography. Four patients had invasive ductal cancer (all axillary node negative) and three had high-grade ductal carcinoma in situ or pleomorphic lobular carcinoma in situ. The three women with in situ disease were all potentially high risk, based on the National Breast and Ovarian Cancer Centre (NBOCC) criteria. Three women with invasive breast cancer were at only average risk based on NBOCC criteria, but two of these had extremely dense breasts. A fourth patient, found to have multifocal invasive cancer, had a personal history of contralateral breast cancer, but no relevant family history. Our findings suggest that breast MRI could be used to screen a larger Australian population at increased risk of developing breast cancer.

  15. The role of magnetic resonance imaging (MRI) and MRI-guided surgery in the evaluation of patients with early stage breast cancer for breast conserving therapy

    International Nuclear Information System (INIS)

    Tan, Jacqueline E.; Orel, Susan G.; Schnall, Mitchell D.; Solin, Lawrence J.

    1997-01-01

    Purpose: Mammography is the primary imaging modality for the detection of breast cancer and the evaluation of patients with early stage breast cancer for breast conserving therapy (BCT). MRI may be more sensitive than mammography for detecting breast cancer and may have an adjunctive role in assessing patients with early stage disease for BCT. Our experience with 83 patients undergoing breast MRI during consideration for breast conserving therapy is analyzed. Materials and Methods: We reviewed 83 consecutive cases of patients undergoing breast MRI during standard work-up and evaluation for BCT from 1993 to 1996. Analysis of cases was limited to women who were AJCC clinical Stage 0, I, or II and who received definitive therapy at our institution. All patients signed informed consent. MRI of the breast was performed at 1.5 Tesla. Sagittal T1 and T2 and 3-D gradient pre- and post-contrast images were obtained. All MRI studies were reviewed by two radiologists. All patients were evaluated by one radiation oncologist. The records of these 83 patients were reviewed for patient age, tumor size, AJCC stage, histology, physical examination findings, mammographic findings, ultrasound findings, MRI findings, timing of first MRI study with respect to excisional surgery, findings from MRI-guided surgery (when done), and whether the patient underwent BCT. Results: The median age at the time of presentation was 51.5 years (range 26-77 years). Of the 83 patients, 16% were AJCC clinical stage 0, 65% were stage I, and 19% were stage II. No patient presented with synchronous bilateral carcinoma. Two patients had a history of prior contralateral breast carcinoma; both received BCT for their initial disease. Sixteen percent of patients had intraductal carcinoma, 39% had intraductal and infiltrating carcinoma, 28% had infiltrating ductal carcinoma, 7% had infiltrating lobular carcinoma, 4% had tubular carcinoma, 2% had adenoid cystic carcinoma, 2% had medullary carcinoma, 1% had colloid

  16. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients

    International Nuclear Information System (INIS)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M.

    2008-01-01

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [de

  17. MRI screening for breast cancer in women at high risk; is the Australian breast MRI screening access program addressing the needs of women at high risk of breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Schenberg, Tess [Department of Medical Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Familial Cancer Centre, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Mitchell, Gillian [Familial Cancer Centre, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville, Victoria (Australia); Taylor, Donna [School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Department of Radiology, Royal Perth Hospital, Perth, Western Australia (Australia); BreastScreen Western Australia, Adelaide Terrace, Perth, Western Australia (Australia); Saunders, Christobel [School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Department of General Surgery, St John of God Hospital, Perth, Western Australia (Australia); Department of Medical Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia)

    2015-09-15

    Breast magnetic resonance imaging (MRI) screening of women under 50 years old at high familial risk of breast cancer was given interim funding by Medicare in 2009 on the basis that a review would be undertaken. An updated literature review has been undertaken by the Medical Services Advisory Committee but there has been no assessment of the quality of the screening or other screening outcomes. This review examines the evidence basis of breast MRI screening and how this fits within an Australian context with the purpose of informing future modifications to the provision of Medicare-funded breast MRI screening in Australia. Issues discussed will include selection of high-risk women, the options for MRI screening frequency and measuring the outcomes of screening.

  18. MRI screening for breast cancer in women at high risk; is the Australian breast MRI screening access program addressing the needs of women at high risk of breast cancer?

    International Nuclear Information System (INIS)

    Schenberg, Tess; Mitchell, Gillian; Taylor, Donna; Saunders, Christobel

    2015-01-01

    Breast magnetic resonance imaging (MRI) screening of women under 50 years old at high familial risk of breast cancer was given interim funding by Medicare in 2009 on the basis that a review would be undertaken. An updated literature review has been undertaken by the Medical Services Advisory Committee but there has been no assessment of the quality of the screening or other screening outcomes. This review examines the evidence basis of breast MRI screening and how this fits within an Australian context with the purpose of informing future modifications to the provision of Medicare-funded breast MRI screening in Australia. Issues discussed will include selection of high-risk women, the options for MRI screening frequency and measuring the outcomes of screening

  19. Growth of breast cancer recurrences assessed by consecutive MRI

    International Nuclear Information System (INIS)

    Millet, Ingrid; Bouic-Pages, Emmanuelle; Hoa, Denis; Azria, David; Taourel, Patrice

    2011-01-01

    Women with a personal history of breast cancer have a high risk of developing an ipsi- or contralateral recurrence. We aimed to compare the growth rate of primary breast cancer and recurrences in women who had undergone prior breast magnetic resonance imaging (MRI). Three hundred and sixty-two women were diagnosed with breast cancer and had undergone breast MRI at the time of diagnosis in our institution (2005 - 2009). Among them, 37 had at least one prior breast MRI with the lesion being visible but not diagnosed as cancer. A linear regression of tumour volume measured on MRI scans and time data was performed using a generalized logistic model to calculate growth rates. The primary objective was to compare the tumour growth rate of patients with either primary breast cancer (no history of breast cancer) or ipsi- or contralateral recurrences of breast cancer. Twenty women had no history of breast cancer and 17 patients were diagnosed as recurrences (7 and 10 were ipsi- and contralateral, respectively). The tumour growth rate was higher in contralateral recurrences than in ipsilateral recurrences (growth rate [10 -3 days -1 ] 3.56 vs 1.38, p < .001) or primary cancer (3.56 vs 2.09, p = 0.01). Differences in tumour growth were not significant for other patient-, tumour- or treatment-related characteristics. These findings suggest that contralateral breast cancer presents accelerated growth compared to ipsilateral recurrences or primary breast events

  20. High-resolution MRI in detecting subareolar breast abscess.

    Science.gov (United States)

    Fu, Peifen; Kurihara, Yasuyuki; Kanemaki, Yoshihide; Okamoto, Kyoko; Nakajima, Yasuo; Fukuda, Mamoru; Maeda, Ichiro

    2007-06-01

    Because subareolar breast abscess has a high recurrence rate, a more effective imaging technique is needed to comprehensively visualize the lesions and guide surgery. We performed a high-resolution MRI technique using a microscopy coil to reveal the characteristics and extent of subareolar breast abscess. High-resolution MRI has potential diagnostic value in subareolar breast abscess. This technique can be used to guide surgery with the aim of reducing the recurrence rate.

  1. Volumetric breast density estimation from full-field digital mammograms.

    Science.gov (United States)

    van Engeland, Saskia; Snoeren, Peter R; Huisman, Henkjan; Boetes, Carla; Karssemeijer, Nico

    2006-03-01

    A method is presented for estimation of dense breast tissue volume from mammograms obtained with full-field digital mammography (FFDM). The thickness of dense tissue mapping to a pixel is determined by using a physical model of image acquisition. This model is based on the assumption that the breast is composed of two types of tissue, fat and parenchyma. Effective linear attenuation coefficients of these tissues are derived from empirical data as a function of tube voltage (kVp), anode material, filtration, and compressed breast thickness. By employing these, tissue composition at a given pixel is computed after performing breast thickness compensation, using a reference value for fatty tissue determined by the maximum pixel value in the breast tissue projection. Validation has been performed using 22 FFDM cases acquired with a GE Senographe 2000D by comparing the volume estimates with volumes obtained by semi-automatic segmentation of breast magnetic resonance imaging (MRI) data. The correlation between MRI and mammography volumes was 0.94 on a per image basis and 0.97 on a per patient basis. Using the dense tissue volumes from MRI data as the gold standard, the average relative error of the volume estimates was 13.6%.

  2. Is the performance of MRI in preoperative staging of breast cancer independent of clinical and histological factors? A subgroup analysis.

    Science.gov (United States)

    Carreira Gómez, C; Zamora Romero, J; Gil de Miguel, A; Chiva de Agustín, M; Plana Farrás, M N; Martínez González, J

    2015-01-01

    To determine whether preoperative breast MRI is more useful in patients according to their breast density, age, menopausal status, and biopsy findings of carcinoma in situ. We retrospectively studied 264 patients treated for breast cancer who had undergone mammography, ultrasonography, and MRI. We compared the size of the tumor on the three techniques and the sensitivity of the techniques for detecting additional lesions both in the overall group and in subgroups of patients classified according to their breast density, age, menopausal status, and histological findings of intraductal carcinoma. The definitive histological diagnosis was used as the gold standard. MRI was the technique that was most concordant with the histological findings for the size of the lesion, and it was also the technique that detected the most additional lesions. With MRI, we observed no differences in lesion size between the overall group and the subgroups in which MRI provided added value. Likewise, we observed no differences in the number of additional lesions detected in the overall group except for multicentric lesions, which was larger in older patients (P=.02). In the subgroup of patients in which MRI provided added value, the sensitivity for bilateral lesions was higher in patients with fatty breasts (P=.04). Multifocal lesions were detected significantly better in premenopausal patients (P=.03). MRI is better than mammography and better than ultrasonography for establishing the size of the tumor and for detecting additional lesions. Our results did not identify any subgroups in which the technique was more useful. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  3. Application of functional MRI in breast diseases

    International Nuclear Information System (INIS)

    Feng Yun; Liu Shiyuan; Wang Chenguang; Tao Xiaofeng; Wang Jinlin; Wang Jian

    2007-01-01

    Objective: To investigate the value of functional MRI in the diagnosis and differential diagnosis of breast diseases. Methods: Sixty-five patients with 68 lesions were enrolled in this study. Conventional T 1 WI and T 2 WI scan, dynamic contrast enhanced MRI, diffusion weighted imaging and 1 H single voxel MR spectroscopy were performed consequently. All lesions were verified by pathology, including 4 cases of breast adenosis, 22 fibroadenomas, 2 chronic inflammations, 3 cysts, 33 infitrating ductal carcinomas, 1 intraductal carcinoma and 3 cystosarcoma phyllodes tumors. Morphological features, maximum enhancement ratio, time-intensity curve, apparent diffusion coefficient and Choline peak were analyzed. Results: The detection rates of T 1 WI and T 2 WI were 14.7% (n=10) and 51.5% (n=35). The sensitivity, specificity, accuracy of dynamic contrast enhanced MRI for the malignant tumor were 94. 6%, 71.4% and 76.5% respectively. Retrospective study showed that diffusion weighted imaging, with the b value from 800 s/mm 2 to 1000 s/mm 2 , could be used to differentiate various types of breast lesions. 1 H signal voxel spectroscopy had a sensitivity of 51.4%, specificity of 82.6%, and accuracy of 67.6% for the malignent. The sensitivity, specificity and accuracy could reach 97.3%, 90.0% and 92.6% respectively by combining conventional scan, dynamic contrast enhanced MRI and MR spectroscopy. Conclusion: Functional MRI, with high sensitivity, specificity and accuracy, can be used widely in the diagnosis of malignant breast lesions. (authors)

  4. Identification of Breast Cancer Using Integrated Information from MRI and Mammography.

    Directory of Open Access Journals (Sweden)

    Shih-Neng Yang

    Full Text Available Integration of information from corresponding regions between the breast MRI and an X-ray mammogram could benefit the detection of breast cancer in clinical diagnosis. We aimed to provide a framework of registration from breast MRI to mammography and to evaluate the diagnosis using the combined information.43 patients with 46 lesions underwent both MRI and mammography scans, and the interval between the two examinations was around one month. The distribution of malignant to benign lesions was 31/46 based on histological results. Maximum intensity projection and thin-plate spline methods were applied for image registration for MRI to mammography. The diagnosis using integrated information was evaluated using results of histology as the reference. The assessment of annotations and statistical analysis were performed by the two radiologists.For the cranio-caudal view, the mean post-registration error between MRI and mammography was 2.2±1.9 mm. For the medio-lateral oblique view, the proposed approach performed even better with a mean error of 3.0±2.4 mm. In the diagnosis using MRI assessment with information of mammography, the sensitivity was 91.9±2.3% (29/31, 28/31, specificity 70.0±4.7% (11/15, 10/15, accuracy 84.8±3.1% (40/46, 38/46, positive predictive value 86.4±2.1% (29/33, 28/33 and negative predictive value 80.8±5.4% (11/13, 10/13.MRI with the aid of mammography shows potential improvements of sensitivity, specificity, accuracy, PPV and NPV in clinical breast cancer diagnosis compared to the use of MRI alone.

  5. Reactive intramammary lymph node mimicking recurrence on MRI study in a patient with prior breast conservation therapy

    Directory of Open Access Journals (Sweden)

    Seema A Kembhavi

    2013-01-01

    Full Text Available Breast conservative therapy (BCT is a well accepted form of treatment for patients with early stage breast cancer. The incidence of ipsilateral breast tumor recurrence is higher in patients undergoing BCT than in those patients undergoing Modified Radical Mastectomy (MRM without any adverse effect on survival. Patients treated with BCT are put on active surveillance using clinical breast examination and mammography. The radiologist reading the follow-up mammograms is on high alert and any neo-density is viewed with suspicion. MRI may be used as a problem solving tool. At such a time, an innocuous intra-mammary node can mimic malignancy on MRI. We want to showcase one such typical example with histological proof and highlight that type III curve may be seen in an intramammary node. Our case also reinforces the utility of second look ultrasound which is a faster, cheaper and easier method for localization and biopsy of abnormalities seen on MRI.

  6. Benign breast disease, mammographic breast density, and the risk of breast cancer.

    Science.gov (United States)

    Tice, Jeffrey A; O'Meara, Ellen S; Weaver, Donald L; Vachon, Celine; Ballard-Barbash, Rachel; Kerlikowske, Karla

    2013-07-17

    Benign breast disease and high breast density are prevalent, strong risk factors for breast cancer. Women with both risk factors may be at very high risk. We included 42818 women participating in the Breast Cancer Surveillance Consortium who had no prior diagnosis of breast cancer and had undergone at least one benign breast biopsy and mammogram; 1359 women developed incident breast cancer in 6.1 years of follow-up (78.1% invasive, 21.9% ductal carcinoma in situ). We calculated hazard ratios (HRs) using Cox regression analysis. The referent group was women with nonproliferative changes and average density. All P values are two-sided. Benign breast disease and breast density were independently associated with breast cancer. The combination of atypical hyperplasia and very high density was uncommon (0.6% of biopsies) but was associated with the highest risk for breast cancer (HR = 5.34; 95% confidence interval [CI] = 3.52 to 8.09, P < .001). Proliferative disease without atypia (25.6% of biopsies) was associated with elevated risk that varied little across levels of density: average (HR = 1.37; 95% CI = 1.11 to 1.69, P = .003), high (HR = 2.02; 95% CI = 1.68 to 2.44, P < .001), or very high (HR = 2.05; 95% CI = 1.54 to 2.72, P < .001). Low breast density (4.5% of biopsies) was associated with low risk (HRs <1) for all benign pathology diagnoses. Women with high breast density and proliferative benign breast disease are at very high risk for future breast cancer. Women with low breast density are at low risk, regardless of their benign pathologic diagnosis.

  7. Clinical Study Pathologic Findings in MRI-Guided Needle Core Biopsies of the Breast in Patients with Newly Diagnosed Breast Cancer

    International Nuclear Information System (INIS)

    Siziopikou, K.P.; Jokich, P.; Cobleigh, M.

    2011-01-01

    The role of MRI in the management of breast carcinoma is rapidly evolving from its initial use for specific indications only to a more widespread use on all women with newly diagnosed early stage breast cancer. However, there are many concerns that such widespread use is premature since detailed correlation of MRI findings with the underlying histopathology of the breast lesions is still evolving and clear evidence for improvements in management and overall prognosis of breast cancer patients evaluated by breast MRI after their initial cancer diagnosis is lacking. In this paper, we would like to bring attention to a benign lesion that is frequently present on MRI-guided breast biopsies performed on suspicious MRI findings in the affected breast of patients with a new diagnosis of breast carcinoma

  8. MRI evaluation of post-mastectomy irradiated breast implants: prevalence and analysis of complications

    International Nuclear Information System (INIS)

    Rella, L.; Telegrafo, M.; Nardone, A.; Milella, A.; Ianora, A.A. Stabile; Lioce, M.; Angelelli, G.; Moschetta, M.

    2015-01-01

    Aim: To evaluate the effect of post-mastectomy radiation therapy (RT) on breast implants as detected by magnetic resonance imaging (MRI) searching for short-term complications. Materials and methods: One hundred and forty patients (total of 144 implants) were evaluated by MRI; 80 (group 1) had undergone RT, whereas the remaining 60 patients (group 2) underwent mastectomy with implant reconstruction without RT. Two radiologists evaluated MRI images searching for implant rupture signs, sub-capsular seromas, capsular contracture, soft-tissue oedema, peri-implant fluid collections. Implant ruptures were classified as severe complications; seromas and capsular contractures as moderate complications; oedema and fluid collections as mild complications. The prevalence of MRI findings in the two groups was calculated and compared by unpaired t-test. Cohen's kappa statistics was used to assess interobserver agreement. Results: Sixty-nine out of 144 (48%) implants presented pathological findings at MRI with complication rates of 47.5 and 48.4 for groups 1 and 2, respectively. Two (5%) severe complications, 10 (26%) moderate complications, and 26 (69%) mild complications occurred in group 1 and surgical treatment was performed in 10 cases. Two (6%) severe complications, seven (23%) moderate complications, and 22 (71%) mild complications occurred in group 2 and surgical treatment was performed in eight cases. No significant difference between the two groups was found (p>0.1). Almost perfect agreement between the two radiologists was found for MRI image detection (k=0.86). Conclusion: RT does not seem to cause a significant effect on breast implants in terms of complication rate in patients undergoing implant-based breast reconstruction. One-stage immediate implant-based breast reconstruction performed at the same time as mastectomy could be proposed. -- Highlights: •RT could increase complication rates of implant-based breast reconstruction (IBR). •No general consensus

  9. Preclinical study of diagnostic performances of contrast-enhanced spectral mammography versus MRI for breast diseases in China.

    Science.gov (United States)

    Wang, Qingguo; Li, Kangan; Wang, Lihui; Zhang, Jianbing; Zhou, Zhiguo; Feng, Yan

    2016-01-01

    To evaluate diagnostic performances of CESM for breast diseases with comparison to breast MRI in China. Sixty-eight patients with 77 breast lesions underwent MR and CESM. Two radiologists interpreted either MRI or CESM images, separately and independently. BI-RADS 1-3 and BI-RADS 4-5 were classified into the suspicious benign and suspicious malignant groups. Diagnostic accuracy parameters were calculated. Receiver operating characteristic (ROC) curves were constructed for the two modalities. The agreement and correlation between maximum lesion diameter based on CESM and MRI, or CESM and pathology were analyzed. Diagnostic accuracy parameters for CESM were sensitivity 95.8 %, specificity 65.5 %, PPV 82.1 %, NPV 90.5 % and accuracy 84.4 %. The diagnostic accuracy parameters for breast MRI were sensitivity 93.8 %, specificity 82.8 %, PPV 88.2 %, NPV 92.3 %and accuracy 89.6 %. Area under the curve (AUC) of ROC was 0.96 for breast MRI and 0.88 for CESM. The Bland-Altman plots showed a mean difference of 0.7 mm with 95 % limits of agreement of 11.4 mm in tumor diameter measured using CESM and breast MRI. The differences of size measurement between CESM and breast MRI were significant, whereas no difference was observed between CESM and pathology as well as between breast MRI and pathology. The better correlation with pathological results was found in CESM than breast MRI. Our study demonstrates that CESM possesses better diagnostic performances than breast MRI in terms of diagnostic sensitivity and lesion size assessment. And CESM is a good alternative method of screening breast cancer in high-risk people.

  10. MRI Background Parenchymal Enhancement Is Not Associated with Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Barbara Bennani-Baiti

    Full Text Available Previously, a strong positive association between background parenchymal enhancement (BPE at magnetic resonance imaging (MRI and breast cancer was reported in high-risk populations. We sought to determine, whether this was also true for non-high-risk patients.540 consecutive patients underwent breast MRI for assessment of breast findings (BI-RADS 0-5, non-high-risk screening (no familial history of breast cancer, no known genetic mutation, no prior chest irradiation, or previous breast cancer diagnosis and subsequent histological work-up. For this IRB-approved study, BPE and fibroglandular tissue FGT were retrospectively assessed by two experienced radiologists according to the BI-RADS lexicon. Pearson correlation coefficients were calculated to explore associations between BPE, FGT, age and final diagnosis of breast cancer. Subsequently, multivariate logistic regression analysis, considering covariate colinearities, was performed, using final diagnosis as the target variable and BPE, FGT and age as covariates.Age showed a moderate negative correlation with FGT (r = -0.43, p<0.001 and a weak negative correlation with BPE (r = -0.28, p<0.001. FGT and BPE correlated moderately (r = 0.35, p<0.001. Final diagnosis of breast cancer displayed very weak negative correlations with FGT (r = -0.09, p = 0.046 and BPE (r = -0.156, p<0.001 and weak positive correlation with age (r = 0.353, p<0.001. On multivariate logistic regression analysis, the only independent covariate for prediction of breast cancer was age (OR 1.032, p<0.001.Based on our data, neither BPE nor FGT independently correlate with breast cancer risk in non-high-risk patients at MRI. Our model retained only age as an independent risk factor for breast cancer in this setting.

  11. Computational simulation of breast compression based on segmented breast and fibroglandular tissues on magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Shih, Tzu-Ching [Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, 40402, Taiwan (China); Chen, Jeon-Hor; Nie Ke; Lin Muqing; Chang, Daniel; Nalcioglu, Orhan; Su, Min-Ying [Tu and Yuen Center for Functional Onco-Imaging and Radiological Sciences, University of California, Irvine, CA 92697 (United States); Liu Dongxu; Sun Lizhi, E-mail: shih@mail.cmu.edu.t [Department of Civil and Environmental Engineering, University of California, Irvine, CA 92697 (United States)

    2010-07-21

    This study presents a finite element-based computational model to simulate the three-dimensional deformation of a breast and fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and craniocaudal and mediolateral oblique compression, as used in mammography, was applied. The geometry of the whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo (registered) 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the nonlinear elastic tissue deformation under compression, using the MSC.Marc (registered) software package. The model was tested in four cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these four cases at a compression ratio of 60% was in the range of 5-7 cm, which is a typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at a compression ratio of 60% was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on magnetic resonance imaging (MRI), which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities--such as MRI, mammography, whole breast ultrasound and molecular imaging--that are performed using different body positions and under

  12. Management of breast lesions detectable only on MRI; Abklaerung ausschliesslich MRT-detektierbarer Mammalaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D. [Universitaetsklinikum Tuebingen (Germany). Abt. Diagnostische und Interventionelle Radiologie

    2014-01-15

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  13. Knowledge of breast density and awareness of related breast cancer risk.

    Science.gov (United States)

    Manning, Mark A; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Penner, Louis; Albrecht, Terrance L

    2013-06-01

    Little is known about women's knowledge of breast density or between-race differences in this knowledge. In the current study, we examined knowledge of breast density and awareness of its role as a breast cancer risk factor among women who had previously taken part in a breast imaging study. Seventy-seven women (54.5 % Black) returned a survey assessing perceptions and accuracy of breast density knowledge, knowledge of one's own breast density, and breast cancer risk awareness. White women had greater perceived knowledge of breast density compared to Black women; however, differences in the accuracy of definitions of breast density were due to education. Black women were less likely to know how dense their own breasts were. Black and White women both lacked awareness that having dense breast increased breast cancer risk. The results highlight the need to disseminate information regarding breast density to women, while ensuring that the information is equally accessible to both Black and White women.

  14. Let's go out of the breast: prevalence of extra-mammary findings and their characterization on breast MRI.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-06-01

    The aim of this study is to assess the prevalence, the site and the nature of extra-mammary findings on breast magnetic resonance imaging (MRI) and to determine its accuracy in the characterization of the discovered lesions. A retrospective review of 308 female patients (mean age 50 ± 20) who underwent breast MRI with 1.5T device was performed. 125 out of 308 (40.5%) had a positive personal history of breast cancer (pre-operative n=80; follow-up n=45), while the remaining 183 without history of breast cancer (high familiar risk for breast cancer n=80; dense breast n=103). All incidental findings were characterized by means of additional imaging (US; Bone scintigraphy-MRI; CT-PET-CT). 59 incidental findings were found in 53/308 (17%) examined patients. 9/59 incidental findings (15%) were confirmed to be malignant while the remaining 50/59 (84%) benign. The most common site was the liver (33/59; 55.8%), followed by the lung (6/59; 10.1%), bone (6/59; 10.1%), diaphragm (6/59; 10.1%) spleen (3/59; 5%), kidney (2/59; 3.4%), gall bladder (1/5; 1.5%), ascending aorta (1/59; 1.5%), thyroid (1/59; 1.5%). The incidence of malignant incidental findings resulted to be higher in the group of patients with personal breast cancer (36%) than in the other one (8%). By comparing MRI findings with the additional definitive imaging tools, breast MRI allowed a correct diagnosis in 58/59 cases with a diagnostic accuracy value of 98%. Incidental extramammary findings on breast MRI are common. Benign lesions represent the most frequent findings, however malignant ones need to be searched especially in patients with personal history of breast cancer because they could influence the clinical patient management. Breast MRI can characterize incidental findings with high accuracy value. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. A novel computer-aided diagnosis system for breast MRI based on feature selection and ensemble learning.

    Science.gov (United States)

    Lu, Wei; Li, Zhe; Chu, Jinghui

    2017-04-01

    Breast cancer is a common cancer among women. With the development of modern medical science and information technology, medical imaging techniques have an increasingly important role in the early detection and diagnosis of breast cancer. In this paper, we propose an automated computer-aided diagnosis (CADx) framework for magnetic resonance imaging (MRI). The scheme consists of an ensemble of several machine learning-based techniques, including ensemble under-sampling (EUS) for imbalanced data processing, the Relief algorithm for feature selection, the subspace method for providing data diversity, and Adaboost for improving the performance of base classifiers. We extracted morphological, various texture, and Gabor features. To clarify the feature subsets' physical meaning, subspaces are built by combining morphological features with each kind of texture or Gabor feature. We tested our proposal using a manually segmented Region of Interest (ROI) data set, which contains 438 images of malignant tumors and 1898 images of normal tissues or benign tumors. Our proposal achieves an area under the ROC curve (AUC) value of 0.9617, which outperforms most other state-of-the-art breast MRI CADx systems. Compared with other methods, our proposal significantly reduces the false-positive classification rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Abbreviated Breast MRI and Digital Tomosynthesis Mammography in Screening Women With Dense Breasts | Division of Cancer Prevention

    Science.gov (United States)

    This randomized phase II trial studies how well abbreviated breast magnetic resonance imaging (MRI) and digital tomosynthesis mammography work in detecting cancer in women with dense breasts. Abbreviated breast MRI is a low cost procedure in which radio waves and a powerful magnet linked to a computer and used to create detailed pictures of the breast in less than 10 minutes.

  17. Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.

    Science.gov (United States)

    Luciani, M L; Pediconi, F; Telesca, M; Vasselli, F; Casali, V; Miglio, E; Passariello, R; Catalano, C

    2011-09-01

    This study prospectively assessed second-look ultrasound (US) for the evaluation of incidental enhancing lesions identified on preoperative breast magnetic resonance imaging (MRI). Between 2004 and 2007, 182 patients with malignant breast lesions detected on US and/or X-ray mammography and confirmed by cytology/histology underwent preoperative breast contrast-enhanced (CE)-MRI. Patients with incidental lesions on breast MRI underwent second-look high-resolution US directed at the site of the incidental finding. Diagnosis of incidental lesions was based on biopsy or 24-month follow-up. Breast MRI detected 55 additional lesions in 46/182 (25.2%) patients. Forty-two of 55 (76.3%) lesions were detected on second-look US in 38/46 (82.6%) patients. Malignancy was confirmed for 24/42 (57.1%) correlate lesions compared with 7/13 (53.8%) noncorrelate lesions. Second-look US depicted 8/9 (88.8%) Breast Imaging Reporting and Data System (BI-RADS) 5, 16/22 (72.7%) BI-RADS 4 and 18/24 (75%) BI-RADS 3 lesions. Sensitivity, specificity, accuracy and positive and negative predictive values for lesion detection/diagnosis was 100%, 88.9%, 94.6%, 90.3% and 100% for MRI and 64.3%, 70.4%, 67.3%, 69.2% and 65.5% for second-look US. Improved performance for US was obtained when masslike lesions only were considered. Second-look US is a confirmatory method for incidental findings on breast MRI, particularly for mass-like lesions.

  18. [Radiologic follow-up after breast-conserving surgery: value of MRI examination of the breast].

    Science.gov (United States)

    Polgár, C; Forrai, G; Szabó, E; Riedl, E; Fodor, J; Fornet, B; Németh, G

    1999-11-21

    The aim of the study was to establish an objective method for evaluation the extent, topography and quantity of skin and soft tissue side effects after tele- and/or brachyradiotherapy of the conserved breast and to compare the sequales of different radiation methods. 26 patients operated on for T1-2 N0-1 breast cancer underwent the following kinds of postoperative radiotherapy: 1. 46-50 Gy whole breast teletherapy + 10-16 Gy electron boost (5 patients), 2. 46-50 Gy teletherapy + 10-15 Gy HDR brachytherapy boost (12 patients), 3. 46-50 Gy teletherapy (6 patients), 4. 36,4 Gy sole HDR brachytherapy of the tumour bed (5 patients). The postirradiation side effects were examined by MRI, mammogram, US and physical examination, as well. MRI was performed on a 0.5 T, double breast coil, with SE-T1, SE-T2 and 3D-GE sequences. The findings of MRI and mammography were compared to physically detectable side effects using the RTOG/EORTC late radiation morbidity scoring scheme. US is useful in the measurement of skin thickening and in the diagnosis of fat necrosis. Mammography and physical examination are very subjective and low specificity methods to evaluate postirradiation side effects. MRI is a suitable and more objective method to detect the real extent and quantity of skin thickening and fibrosis. The incidence of > or = G2 side effects of skin and breast parenchyma were 64.5 and 32.2%, respectively. The differences between the side effects of whole breast irradiation and sole brachytherapy of the tumour bed are also clearly demonstrated. Brachytherapy alone is feasible without compromising cosmetic results. The authors established the MRI criteria for categorization the extent and grade of skin thickening and fibrosis (focal vs diffuse, grade 1-4). Breast MRI is an objective tool for assisting to the evaluation of the side effects of postoperative radiotherapy.

  19. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hye Young [Department of Radiology, Gyeongsang National University Hospital, Jinju 660-702 (Korea, Republic of); Kim, Sun Mi; Jang, Mijung; Yun, Bo La [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Kim, Sung-Won; Kang, Eunyoung [Department of Surgery, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Park, So Yeon [Department of Pathology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Ko, Eun Sook [Department of Radiology, Samsung Medical Center, Seoul 135-710 (Korea, Republic of)

    2013-07-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions.

  20. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Sung-Won; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Ko, Eun Sook

    2013-01-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions

  1. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  2. Vision 20/20: Mammographic breast density and its clinical applications

    International Nuclear Information System (INIS)

    Ng, Kwan-Hoong; Lau, Susie

    2015-01-01

    Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which women are “dense” and what imaging modality is suitable for individual women. To date, mammographic breast density has been classified according to the Breast Imaging-Reporting and Data System (BI-RADS) categories from visual assessment, but this is known to be very subjective. Despite many research reports, the authors believe there has been a lack of physics-led and evidence-based arguments about what breast density actually is, how it should be measured, and how it should be used. In this paper, the authors attempt to start correcting this situation by reviewing the history of breast density research and the debates generated by the advocacy movement. The authors review the development of breast density estimation from pattern analysis to area-based analysis, and the current automated volumetric breast density (VBD) analysis. This is followed by a discussion on seeking the ground truth of VBD and mapping volumetric methods to BI-RADS density categories. The authors expect great improvement in VBD measurements that will satisfy the needs of radiologists, epidemiologists, surgeons, and physicists. The authors believe that they are now witnessing a paradigm shift toward personalized breast screening, which is going to see many more cancers being detected early, with the use of automated density measurement tools as an important component

  3. Vision 20/20: Mammographic breast density and its clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan-Hoong, E-mail: ngkh@ummc.edu.my; Lau, Susie [Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-12-15

    Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which women are “dense” and what imaging modality is suitable for individual women. To date, mammographic breast density has been classified according to the Breast Imaging-Reporting and Data System (BI-RADS) categories from visual assessment, but this is known to be very subjective. Despite many research reports, the authors believe there has been a lack of physics-led and evidence-based arguments about what breast density actually is, how it should be measured, and how it should be used. In this paper, the authors attempt to start correcting this situation by reviewing the history of breast density research and the debates generated by the advocacy movement. The authors review the development of breast density estimation from pattern analysis to area-based analysis, and the current automated volumetric breast density (VBD) analysis. This is followed by a discussion on seeking the ground truth of VBD and mapping volumetric methods to BI-RADS density categories. The authors expect great improvement in VBD measurements that will satisfy the needs of radiologists, epidemiologists, surgeons, and physicists. The authors believe that they are now witnessing a paradigm shift toward personalized breast screening, which is going to see many more cancers being detected early, with the use of automated density measurement tools as an important component.

  4. Fat saturation in dynamic breast MRI at 3 Tesla: is the Dixon technique superior to spectral fat saturation? A visual grading characteristics study

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, P. [University of Udine, Azienda Ospedaliero-Universitaria ' ' S.Maria della Misericordia' ' , Institute of Diagnostic Radiology, Udine (Italy); Medical University of Vienna, Department of Biomedical Imaging and Image-guided interventions, Division of Molecular and Gender Imaging, Vienna (Austria); Pinker, K.; Helbich, T.H.; Kapetas, P.; Bernathova, M.; Baltzer, P.A.T. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided interventions, Division of Molecular and Gender Imaging, Vienna (Austria)

    2014-09-15

    To intra-individually compare the diagnostic image quality of Dixon and spectral fat suppression at 3 T. Fifty consecutive patients (mean age 55.1 years) undergoing 3 T breast MRI were recruited for this prospective study. The image protocol included pre-contrast and delayed post-contrast spectral and Dixon fat-suppressed T1w series. Two independent blinded readers compared spectral and Dixon fat-suppressed series by evaluating six ordinal (1 worst to 5 best) image quality criteria (image quality, delineation of anatomical structures, fat suppression in the breast and axilla, lesion delineation and internal enhancement). Breast density and size were assessed. Data analysis included Spearman's rank correlation coefficient and visual grading characteristics (VGC) analysis. Four examinations were excluded; 48 examinations in 46 patients were evaluated. In VGC analysis, the Dixon technique was superior regarding image quality criteria analysed (P < 0.01). Smaller breast size and lower breast density were significantly (P < 0.01) correlated with impaired spectral fat suppression quality. No such correlation was identified for the Dixon technique, which showed reconstruction-based water-fat mixups leading to insufficient image quality in 20.8 %. The Dixon technique outperformed spectral fat suppression in all evaluated criteria (P < 0.01). Non-diagnostic examinations can be avoided by fat and water image reconstruction. The superior image quality of the Dixon technique can improve breast MRI interpretation. (orig.)

  5. Let's go out of the breast: Prevalence of extra-mammary findings and their characterization on breast MRI

    International Nuclear Information System (INIS)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-01-01

    Purpose: The aim of this study is to assess the prevalence, the site and the nature of extra-mammary findings on breast magnetic resonance imaging (MRI) and to determine its accuracy in the characterization of the discovered lesions. Materials and methods: A retrospective review of 308 female patients (mean age 50 ± 20) who underwent breast MRI with 1.5 T device was performed. 125 out of 308 (40.5%) had a positive personal history of breast cancer (pre-operative n = 80; follow-up n = 45), while the remaining 183 without history of breast cancer (high familiar risk for breast cancer n = 80; dense breast n = 103). All incidental findings were characterized by means of additional imaging (US; Bone scintigraphy-MRI; CT-PET-CT). Results: 59 incidental findings were found in 53/308 (17%) examined patients. 9/59 incidental findings (15%) were confirmed to be malignant while the remaining 50/59 (84%) benign. The most common site was the liver (33/59; 55.8%), followed by the lung (6/59; 10.1%), bone (6/59; 10.1%), diaphragm (6/59; 10.1%) spleen (3/59; 5%), kidney (2/59; 3.4%), gall bladder (1/5; 1.5%), ascending aorta (1/59; 1.5%), thyroid (1/59; 1.5%). The incidence of malignant incidental findings resulted to be higher in the group of patients with personal breast cancer (36%) than in the other one (8%). By comparing MRI findings with the additional definitive imaging tools, breast MRI allowed a correct diagnosis in 58/59 cases with a diagnostic accuracy value of 98%. Conclusion: Incidental extramammary findings on breast MRI are common. Benign lesions represent the most frequent findings, however malignant ones need to be searched especially in patients with personal history of breast cancer because they could influence the clinical patient management. Breast MRI can characterize incidental findings with high accuracy value

  6. Let's go out of the breast: Prevalence of extra-mammary findings and their characterization on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Moschetta, Marco, E-mail: marco.moschetta@gmail.com; Telegrafo, Michele, E-mail: mikitele@hotmail.it; Rella, Leonarda, E-mail: lea.rella@gmail.com; Stabile Ianora, Amato Antonio, E-mail: a.stabile@radiologia.uniba.it; Angelelli, Giuseppe, E-mail: g.angellelli@radiologia.uniba.it

    2014-06-15

    Purpose: The aim of this study is to assess the prevalence, the site and the nature of extra-mammary findings on breast magnetic resonance imaging (MRI) and to determine its accuracy in the characterization of the discovered lesions. Materials and methods: A retrospective review of 308 female patients (mean age 50 ± 20) who underwent breast MRI with 1.5 T device was performed. 125 out of 308 (40.5%) had a positive personal history of breast cancer (pre-operative n = 80; follow-up n = 45), while the remaining 183 without history of breast cancer (high familiar risk for breast cancer n = 80; dense breast n = 103). All incidental findings were characterized by means of additional imaging (US; Bone scintigraphy-MRI; CT-PET-CT). Results: 59 incidental findings were found in 53/308 (17%) examined patients. 9/59 incidental findings (15%) were confirmed to be malignant while the remaining 50/59 (84%) benign. The most common site was the liver (33/59; 55.8%), followed by the lung (6/59; 10.1%), bone (6/59; 10.1%), diaphragm (6/59; 10.1%) spleen (3/59; 5%), kidney (2/59; 3.4%), gall bladder (1/5; 1.5%), ascending aorta (1/59; 1.5%), thyroid (1/59; 1.5%). The incidence of malignant incidental findings resulted to be higher in the group of patients with personal breast cancer (36%) than in the other one (8%). By comparing MRI findings with the additional definitive imaging tools, breast MRI allowed a correct diagnosis in 58/59 cases with a diagnostic accuracy value of 98%. Conclusion: Incidental extramammary findings on breast MRI are common. Benign lesions represent the most frequent findings, however malignant ones need to be searched especially in patients with personal history of breast cancer because they could influence the clinical patient management. Breast MRI can characterize incidental findings with high accuracy value.

  7. Abbreviated protocol for breast MRI: Are multiple sequences needed for cancer detection?

    International Nuclear Information System (INIS)

    Mango, Victoria L.; Morris, Elizabeth A.; David Dershaw, D.; Abramson, Andrea; Fry, Charles; Moskowitz, Chaya S.; Hughes, Mary; Kaplan, Jennifer; Jochelson, Maxine S.

    2015-01-01

    Highlights: • Abbreviated breast MR demonstrates high sensitivity for breast carcinoma detection. • Time to perform/interpret the abbreviated exam is shorter than a standard MRI exam. • An abbreviated breast MRI could reduce costs and make MRI screening more available. - Abstract: Objective: To evaluate the ability of an abbreviated breast magnetic resonance imaging (MRI) protocol, consisting of a precontrast T1 weighted (T1W) image and single early post-contrast T1W image, to detect breast carcinoma. Materials and methods: A HIPAA compliant Institutional Review Board approved review of 100 consecutive breast MRI examinations in patients with biopsy proven unicentric breast carcinoma. 79% were invasive carcinomas and 21% were ductal carcinoma in situ. Four experienced breast radiologists, blinded to carcinoma location, history and prior examinations, assessed the abbreviated protocol evaluating only the first post-contrast T1W image, post-processed subtracted first post-contrast and subtraction maximum intensity projection images. Detection and localization of tumor were compared to the standard full diagnostic examination consisting of 13 pre-contrast, post-contrast and post-processed sequences. Results: All 100 cancers were visualized on initial reading of the abbreviated protocol by at least one reader. The mean sensitivity for each sequence was 96% for the first post-contrast sequence, 96% for the first post-contrast subtraction sequence and 93% for the subtraction MIP sequence. Within each sequence, there was no significant difference between the sensitivities among the 4 readers (p = 0.471, p = 0.656, p = 0.139). Mean interpretation time was 44 s (range 11–167 s). The abbreviated imaging protocol could be performed in approximately 10–15 min, compared to 30–40 min for the standard protocol. Conclusion: An abbreviated breast MRI protocol allows detection of breast carcinoma. One pre and post-contrast T1W sequence may be adequate for detecting

  8. Abbreviated protocol for breast MRI: Are multiple sequences needed for cancer detection?

    Energy Technology Data Exchange (ETDEWEB)

    Mango, Victoria L., E-mail: vlm2125@columbia.edu [Columbia University Medical Center, Herbert Irving Pavilion, 161 Fort Washington Avenue, 10th Floor, New York, NY 10032 (United States); Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Morris, Elizabeth A., E-mail: morrise@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); David Dershaw, D., E-mail: dershawd@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Abramson, Andrea, E-mail: abramsoa@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Fry, Charles, E-mail: charles_fry@nymc.edu [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); New York Medical College, 40 Sunshine Cottage Rd, Valhalla, NY 10595 (United States); Moskowitz, Chaya S. [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Hughes, Mary, E-mail: hughesm@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Kaplan, Jennifer, E-mail: kaplanj@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States); Jochelson, Maxine S., E-mail: jochelsm@mskcc.org [Memorial Sloan-Kettering Cancer Center, Breast and Imaging Center, 300 East 66th Street, New York, NY 10065 (United States)

    2015-01-15

    Highlights: • Abbreviated breast MR demonstrates high sensitivity for breast carcinoma detection. • Time to perform/interpret the abbreviated exam is shorter than a standard MRI exam. • An abbreviated breast MRI could reduce costs and make MRI screening more available. - Abstract: Objective: To evaluate the ability of an abbreviated breast magnetic resonance imaging (MRI) protocol, consisting of a precontrast T1 weighted (T1W) image and single early post-contrast T1W image, to detect breast carcinoma. Materials and methods: A HIPAA compliant Institutional Review Board approved review of 100 consecutive breast MRI examinations in patients with biopsy proven unicentric breast carcinoma. 79% were invasive carcinomas and 21% were ductal carcinoma in situ. Four experienced breast radiologists, blinded to carcinoma location, history and prior examinations, assessed the abbreviated protocol evaluating only the first post-contrast T1W image, post-processed subtracted first post-contrast and subtraction maximum intensity projection images. Detection and localization of tumor were compared to the standard full diagnostic examination consisting of 13 pre-contrast, post-contrast and post-processed sequences. Results: All 100 cancers were visualized on initial reading of the abbreviated protocol by at least one reader. The mean sensitivity for each sequence was 96% for the first post-contrast sequence, 96% for the first post-contrast subtraction sequence and 93% for the subtraction MIP sequence. Within each sequence, there was no significant difference between the sensitivities among the 4 readers (p = 0.471, p = 0.656, p = 0.139). Mean interpretation time was 44 s (range 11–167 s). The abbreviated imaging protocol could be performed in approximately 10–15 min, compared to 30–40 min for the standard protocol. Conclusion: An abbreviated breast MRI protocol allows detection of breast carcinoma. One pre and post-contrast T1W sequence may be adequate for detecting

  9. Novel techniques for 7 tesla breast MRI

    NARCIS (Netherlands)

    van der Velden, T.A.

    2017-01-01

    This thesis introduced several new techniques to the field of 7 tesla breast MRI, enabling high field multi-parametric MR imaging and, potentially, patient specific treatment planning. Chapter 2 described the development of a RF coil setup for bilateral breast MR imaging and 31P spectroscopy. This

  10. Does breast density measured through population-based screening independently increase breast cancer risk in Asian females?

    Directory of Open Access Journals (Sweden)

    Park B

    2017-12-01

    Full Text Available Boyoung Park,1,2 Hye Mi Cho,2 Eun Hye Lee,3 Seunghoon Song,2 Mina Suh,2 Kui Son Choi,1,2 Bong Joo Kang,4 Kyungran Ko,5 Ann Yi,6 Hae Kyoung Jung,7 Joo Hee Cha,8 Jae Kwan Jun,1,2 1National Cancer Center Graduate School of Cancer Science and Policy, Goyang, Republic of Korea; 2National Cancer Control Institute, National Cancer Center, Goyang, Republic of Korea; 3Department of Radiology, Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Republic of Korea; 4Department of Radiology, Seoul St Mary’s Hospital, Catholic University of Korea College of Medicine, Seoul, Republic of Korea; 5Center for Breast Cancer, National Cancer Center Hospital, National Cancer Center, Goyang, Republic of Korea; 6Department of Radiology, Seoul National University Hospital Healthcare System Gangnam Center, Seoul, Republic of Korea; 7Department of Radiology, CHA Bundang Medical Center, CHA University, Seongnam, Republic of Korea; 8Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea Purpose: The purpose of this study was to investigate the effects of breast density on breast cancer risk among women screened via a nationwide mammographic screening program. Patients and methods: We conducted a nested case–control study for a randomly selected population of 1,561 breast cancer patients and 6,002 matched controls from the National Cancer Screening Program. Breast density was measured and recorded by two independent radiologists using the Breast Imaging Reporting and Data System (BI-RADS. Associations between BI-RADS density and breast cancer risk were evaluated according to screening results, time elapsed since receiving non-recall results, age, and menopausal status after adjusting for possible covariates. Results: Breast cancer risk for women with extremely dense breasts was five times higher (adjusted odds ratio [aOR] =5.0; 95% confidence interval [CI] =3

  11. Abbreviated MRI protocols for detecting breast cancer in women with dense breasts

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shung Qing; Huang, Min; Shen, Yu Ying; Liu, Chen Lu; Xu, Chuan Xiao [The Affiliated Suzhou Hospital, Nanjing Medical University, Suzhou (China)

    2017-06-15

    To evaluate the validity of two abbreviated protocols (AP) of MRI in breast cancer screening of dense breast tissue. This was a retrospective study in 356 participants with dense breast tissue and negative mammography results. The study was approved by the Nanjing Medical University Ethics Committee. Patients were imaged with a full diagnostic protocol (FDP) of MRI. Two APs (AP-1 consisting of the first post-contrast subtracted [FAST] and maximum-intensity projection [MIP] images, and AP-2 consisting of AP-1 combined with diffusion-weighted imaging [DWI]) and FDP images were analyzed separately, and the sensitivities and specificities of breast cancer detection were calculated. Of the 356 women, 67 lesions were detected in 67 women (18.8%) by standard MR protocol, and histological examination revealed 14 malignant lesions and 53 benign lesions. The average interpretation time of AP-1 and AP-2 were 37 seconds and 54 seconds, respectively, while the average interpretation time of the FDP was 3 minutes and 25 seconds. The sensitivities of the AP-1, AP-2, and FDP were 92.9, 100, and 100%, respectively, and the specificities of the three MR protocols were 86.5, 95.0, and 96.8%, respectively. There was no significant difference among the three MR protocols in the diagnosis of breast cancer (p > 0.05). However, the specificity of AP-1 was significantly lower than that of AP-2 (p = 0.031) and FDP (p = 0.035), while there was no difference between AP-2 and FDP (p > 0.05). The AP may be efficient in the breast cancer screening of dense breast tissue. FAST and MIP images combined with DWI of MRI are helpful to improve the specificity of breast cancer detection.

  12. Computerized image analysis: estimation of breast density on mammograms

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Petrick, Nicholas; Sahiner, Berkman; Helvie, Mark A.; Roubidoux, Marilyn A.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.

    2000-06-01

    An automated image analysis tool is being developed for estimation of mammographic breast density, which may be useful for risk estimation or for monitoring breast density change in a prevention or intervention program. A mammogram is digitized using a laser scanner and the resolution is reduced to a pixel size of 0.8 mm X 0.8 mm. Breast density analysis is performed in three stages. First, the breast region is segmented from the surrounding background by an automated breast boundary-tracking algorithm. Second, an adaptive dynamic range compression technique is applied to the breast image to reduce the range of the gray level distribution in the low frequency background and to enhance the differences in the characteristic features of the gray level histogram for breasts of different densities. Third, rule-based classification is used to classify the breast images into several classes according to the characteristic features of their gray level histogram. For each image, a gray level threshold is automatically determined to segment the dense tissue from the breast region. The area of segmented dense tissue as a percentage of the breast area is then estimated. In this preliminary study, we analyzed the interobserver variation of breast density estimation by two experienced radiologists using BI-RADS lexicon. The radiologists' visually estimated percent breast densities were compared with the computer's calculation. The results demonstrate the feasibility of estimating mammographic breast density using computer vision techniques and its potential to improve the accuracy and reproducibility in comparison with the subjective visual assessment by radiologists.

  13. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting.

    Science.gov (United States)

    van der Waal, Daniëlle; den Heeten, Gerard J; Pijnappel, Ruud M; Schuur, Klaas H; Timmers, Johanna M H; Verbeek, André L M; Broeders, Mireille J M

    2015-01-01

    The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised screening or screening evaluation. Digital mammographic exams (N = 992) of women participating in the Dutch breast cancer screening programme (age 50-75y) in 2013 were included. Breast density was measured in three different ways: BI-RADS density (5th edition) and with two commercially available automated software programs (Quantra and Volpara volumetric density). BI-RADS density (ordinal scale) was assessed by three radiologists. Quantra (v1.3) and Volpara (v1.5.0) provide continuous estimates. Different comparison methods were used, including Bland-Altman plots and correlation coefficients (e.g., intraclass correlation coefficient [ICC]). Based on the BI-RADS classification, 40.8% of the women had 'heterogeneously or extremely dense' breasts. The median volumetric percent density was 12.1% (IQR: 9.6-16.5) for Quantra, which was higher than the Volpara estimate (median 6.6%, IQR: 4.4-10.9). The mean difference between Quantra and Volpara was 5.19% (95% CI: 5.04-5.34) (ICC: 0.64). There was a clear increase in volumetric percent dense volume as BI-RADS density increased. The highest accuracy for predicting the presence of BI-RADS c+d (heterogeneously or extremely dense) was observed with a cut-off value of 8.0% for Volpara and 13.8% for Quantra. Although there was no perfect agreement, there appeared to be a strong association between all three measures. Both volumetric density measures seem to be usable in breast cancer screening programmes, provided that the required data flow can be realized.

  14. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. A Case Report of Breast Sparganosis in a Patient with Ipsilateral Breast Cancer: MRI and Ultrasonographic Findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoo Jin; Bae, Young Tae; Kim, Jee Yeon [Pusan National University Hospital, Pusan National University School of Medicine, Busan (Korea, Republic of); Choo, Ki Seok [Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2010-12-15

    Sparganosis of the breast is a quite rare parasitic infection of humans and presents as soft tissue masses that mimic breast malignancy or benign tumor, such as fibroadenoma. We present here a case of histologically confirmed breast sparganosis in the upper inner quadrant of the right breast with coexisting breast cancer in the ipsilateral breast upper outer quadrant. Ultrasonography of breast sparganosis showed a well defined, tubular hypoechoic mass with discrete multilayered wall and tubule-in tubule appearance, surrounded by heterogenous hyperechoic areas in the subcutaneous fat layer of the breast. MRI revealed an elongated tubular structure with persistent and progressive enhancement. This is the second report concerned with the MRI and ultrasonographic findings of breast sparganosis and the first report of breast sparganosis in a patient with ipsilateral breast cancer

  16. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  17. MRI evaluation of post-mastectomy irradiated breast implants: prevalence and analysis of complications.

    Science.gov (United States)

    Rella, L; Telegrafo, M; Nardone, A; Milella, A; Stabile Ianora, A A; Lioce, M; Angelelli, G; Moschetta, M

    2015-09-01

    To evaluate the effect of post-mastectomy radiation therapy (RT) on breast implants as detected by magnetic resonance imaging (MRI) searching for short-term complications. One hundred and forty patients (total of 144 implants) were evaluated by MRI; 80 (group 1) had undergone RT, whereas the remaining 60 patients (group 2) underwent mastectomy with implant reconstruction without RT. Two radiologists evaluated MRI images searching for implant rupture signs, sub-capsular seromas, capsular contracture, soft-tissue oedema, peri-implant fluid collections. Implant ruptures were classified as severe complications; seromas and capsular contractures as moderate complications; oedema and fluid collections as mild complications. The prevalence of MRI findings in the two groups was calculated and compared by unpaired t-test. Cohen's kappa statistics was used to assess interobserver agreement. Sixty-nine out of 144 (48%) implants presented pathological findings at MRI with complication rates of 47.5 and 48.4 for groups 1 and 2, respectively. Two (5%) severe complications, 10 (26%) moderate complications, and 26 (69%) mild complications occurred in group 1 and surgical treatment was performed in 10 cases. Two (6%) severe complications, seven (23%) moderate complications, and 22 (71%) mild complications occurred in group 2 and surgical treatment was performed in eight cases. No significant difference between the two groups was found (p>0.1). Almost perfect agreement between the two radiologists was found for MRI image detection (k=0.86). RT does not seem to cause a significant effect on breast implants in terms of complication rate in patients undergoing implant-based breast reconstruction. One-stage immediate implant-based breast reconstruction performed at the same time as mastectomy could be proposed. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Breast MRI in Invasive Lobular Carcinoma: A Useful Investigation in Surgical Planning?

    Science.gov (United States)

    Parvaiz, Muhammad Asad; Yang, Peiming; Razia, Eisha; Mascarenhas, Margaret; Deacon, Caroline; Matey, Pilar; Isgar, Brian; Sircar, Tapan

    2016-01-01

    Magnetic resonance imaging (MRI) is highly sensitive in detecting invasive lobular carcinoma (ILC) of the breast. In our institution, patients who are deemed to be suitable for breast conserving surgery (BCS) with unifocal small ILC on standard imaging are offered breast MRI to exclude multifocal and larger ILC. Our study investigates the usefulness of breast MRI in ILC. A prospective cohort study over a 58-month period, including all consecutive patients with ILC having breast MRI. Primary objective was to find out the proportion of ILC patients where preoperative MRI caused a change in the surgical treatment. Secondary objectives included finding mastectomy rate (initial & final), re-operation rate, cancer size correlation with different imaging modalities and final histopathology, loco-regional recurrence and disease-free survival. A total of 334 bilateral breast MRI were performed including 72 (21.5%) MRI for ILC patients. All these MRI were carried out within 2 week of patients given the diagnosis (median 5.5 days). Age range was 24-83 (median 56.5) years. Nineteen of 72 ILC patients (26.4%) had a change in their planned operation from BCS to a different operation owing to MRI findings (seven patients with multifocal cancers, 10 with significantly larger size of the cancer and two with contralateral malignancy). Initial mastectomy rate was 31.9%, final mastectomy rate was 36.1% and re-operation rate in BCS group was 18.3%. MRI correlated better with ILC histopathology cancer size than mammogram and ultrasound scans. There was no statistically significant difference (p = 0.999) between the cancer size on histology (median 23 mm) and MRI (median 25 mm). However, mammogram (median 17 mm) and ultrasound (median 14.5 mm) scans showed cancer sizes significantly different to final histology cancer size (p = 0.0008 and p = 0.0021 respectively). Over a 44 months median follow-up (range 27-85), 95.8% disease-free survival and 98.6% overall survival have been observed

  19. Dose Tc-99m MIBI scintimammography provide more information additive to contrast enhanced MRI in highly suspected breast cancer patients?

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate whether Tc-99m MIBI scintimammography (SMM) provide more information than contrast enhanced MRI in highly suspected breast cancer patients. This study included 32 breast lesions of 29 highly suspected patients having breast cancer. All patients were performed SMM and contrast enhanced MRI. The SMMs and contrast enhanced MRI were correlated with histopathologic results. Thirty breast lesions were diagnosed malignant diseases and 2 were diagnosed benign diseases. SMM showed 29 true positives (TP), 1 true negative (TN), 1 false positive (FP), and 1 false negative (FN). The sensitivity was 96.6%. Contrast enhanced MRI revealed 24 TP, 0 TN, 1 FP, 3 FN and 4 indeterminate cases. The sensitivity was 88.8%. In the assessment of axillary lymph node metastasis, SMM showed 9 TP, 10 TN, 0 FP, and 3 FN. The sensitivity and specificity were 75% and 100%. Contrast enhanced MRI revealed 6 TP, 9 TN, 1 FP, and 6 FN. The sensitivity and specificity were 50% and 90%. Among 4 indeterminate cases with MRI findings, SMM correctly diagnosed malignant breast diseases in 3 lesions. However, SMM showed false positive in 1 lesion. SMM could correctly diagnosed malignant breast diseases more 5 lesions than contrast enhanced MRI. SMM revealed higher sensitivity in detection of primary breast cancer and axillary LN metastasis than contrast enhanced MRI. SMMs could correctly diagnosed malignant breast diseases even if the MRI showed indeterminate findings. In highly suspected patients having breast cancer, SMM may provide additive information in detection of breast cancer if contrast enhanced MRI showed indeterminate findings but this is to be determined later by large population based study

  20. Breast cancer molecular subtype classifier that incorporates MRI features.

    Science.gov (United States)

    Sutton, Elizabeth J; Dashevsky, Brittany Z; Oh, Jung Hun; Veeraraghavan, Harini; Apte, Aditya P; Thakur, Sunitha B; Morris, Elizabeth A; Deasy, Joseph O

    2016-07-01

    To use features extracted from magnetic resonance (MR) images and a machine-learning method to assist in differentiating breast cancer molecular subtypes. This retrospective Health Insurance Portability and Accountability Act (HIPAA)-compliant study received Institutional Review Board (IRB) approval. We identified 178 breast cancer patients between 2006-2011 with: 1) ERPR + (n = 95, 53.4%), ERPR-/HER2 + (n = 35, 19.6%), or triple negative (TN, n = 48, 27.0%) invasive ductal carcinoma (IDC), and 2) preoperative breast MRI at 1.5T or 3.0T. Shape, texture, and histogram-based features were extracted from each tumor contoured on pre- and three postcontrast MR images using in-house software. Clinical and pathologic features were also collected. Machine-learning-based (support vector machines) models were used to identify significant imaging features and to build models that predict IDC subtype. Leave-one-out cross-validation (LOOCV) was used to avoid model overfitting. Statistical significance was determined using the Kruskal-Wallis test. Each support vector machine fit in the LOOCV process generated a model with varying features. Eleven out of the top 20 ranked features were significantly different between IDC subtypes with P machine-learning-based predictive model using features extracted from MRI that can distinguish IDC subtypes with significant predictive power. J. Magn. Reson. Imaging 2016;44:122-129. © 2016 Wiley Periodicals, Inc.

  1. Comparison of intraductal spread on dynamic contrast-enhanced MRI with clinicopathologic features in breast cancer

    International Nuclear Information System (INIS)

    Komatsu, Shuhei; Lee, Chol-Joo; Hosokawa, Yohei; Ichikawa, Daisuke; Hamashima, Takashi; Shirono, Koichi; Okabe, Harumi; Kurioka, Hideaki; Oka, Takahiro

    2004-01-01

    Contrast-enhanced magnetic resonance imaging (CE-MRI) has emerged as a new diagnostic technology in various breast cancer treatments. However, little is known about the correlation between intraductal spread on CE-MRI and clinicopathologic features. This study was designed to evaluate these correlations for the surgical planning of breast cancer. Twenty-six breast cancer lesions (in 26 female patients) treated by breast conserving surgery between March 2001 and March 2003 were evaluated retrospectively. CE-MRI was performed with a 1.5 T unit using a dedicated bilateral breast coil. In detecting intraductal spread of breast cancer, the sensitivity, specificity and accuracy of CE-MRI were 82.4%, 60.0% and 77.3%, respectively. On mammography (MMG), these were 21.1%, 100.0% and 42.3%, respectively. Therefore, CE-MRI has a higher sensitivity and accuracy, although with a lower specificity than MMG. Compared with breast cancer lesions without intraductal spread on CE-MRI, lesions with intraductal spread on CE-MRI were found more frequently in larger-sized tumors (P=0.0088). Preoperative evaluation for intraductal spread by CE-MRI should be more useful than by MMG for breast cancer. When making the surgical decision regarding excision range, particular attention should be paid to this consideration for patients with larger-sized cancer tumors. (author)

  2. Invasive lobular carcinoma of the breast: MRI pathological correlation following bilateral total mastectomy

    International Nuclear Information System (INIS)

    Stivalet, Aude; Pigneur, Frederic; Luciani, Alain

    2012-01-01

    Background: Invasive lobular carcinoma (ILC) is more often multifocal and bilateral than invasive ductal carcinoma. MRI is usually recommended for detection of all ILC sites. The performance of known diagnostic breast MRI criteria for ILC characterization has not been evaluated to date using bilateral mastectomy specimens as gold standard. Purpose: To determine the value of BI-RADS 2006 MRI criteria for ILC detection and characterization, using pathological examination of bilateral mastectomy specimens as the reference standard. Material and Methods: Between 2004 and 2007, we retrospectively included all patients with pathologically documented ILC referred to our institution for bilateral mastectomy and preoperative bilateral breast MRI. The location, diameter, and characteristics (BI-RADS) of all lesions were compared with pathological findings. The sensitivity and positive predictive value of bilateral breast MRI for the diagnosis of ILC were calculated. Association of MRI BI-RADS categorical variables and characterization of ILC were assessed (Fisher exact test). Results: Among 360 patients treated for ILC in 2004-2007, 15 patients qualified for this study. Thirty-one ILC foci were found on pathological examination (30 ipsilateral and 1 contralateral tumor; mean diameter 23 mm; range 2-60 mm) and all were identified on MRI, with 90% of masses and 10% non-mass-like enhancements; MRI features significantly associated with ILC included absence of smooth margins (P = 0.02) and rim-shaped enhancement (P = 0.039). Enhancement kinetics of the 31 foci were evenly distributed among wash-out, plateau, and persistent profiles. Eleven additional lesions were seen on MRI, mainly corresponding to fibrocystic disease; 91% presented as masses and 9% had a wash-out profile. Conclusion: Based on the 2006 BI-RADS criteria, breast MRI shows a high sensitivity for ILC detection, at the expense of a 26% false-positive rate, suggesting that a pathological proof by US- or MR

  3. Invasive lobular carcinoma of the breast: MRI pathological correlation following bilateral total mastectomy

    Energy Technology Data Exchange (ETDEWEB)

    Stivalet, Aude; Pigneur, Frederic (AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, Creteil (France)); Luciani, Alain (AP-HP, Groupe Henri Mondor Albert Chenevier, Imagerie Medicale, Creteil (France); INSERM Unite U 955, Equipe 17, Univ. Paris Est Creteil, Creteil (France)), email: alain.luciani@hmn.aphp.fr (and others)

    2012-05-15

    Background: Invasive lobular carcinoma (ILC) is more often multifocal and bilateral than invasive ductal carcinoma. MRI is usually recommended for detection of all ILC sites. The performance of known diagnostic breast MRI criteria for ILC characterization has not been evaluated to date using bilateral mastectomy specimens as gold standard. Purpose: To determine the value of BI-RADS 2006 MRI criteria for ILC detection and characterization, using pathological examination of bilateral mastectomy specimens as the reference standard. Material and Methods: Between 2004 and 2007, we retrospectively included all patients with pathologically documented ILC referred to our institution for bilateral mastectomy and preoperative bilateral breast MRI. The location, diameter, and characteristics (BI-RADS) of all lesions were compared with pathological findings. The sensitivity and positive predictive value of bilateral breast MRI for the diagnosis of ILC were calculated. Association of MRI BI-RADS categorical variables and characterization of ILC were assessed (Fisher exact test). Results: Among 360 patients treated for ILC in 2004-2007, 15 patients qualified for this study. Thirty-one ILC foci were found on pathological examination (30 ipsilateral and 1 contralateral tumor; mean diameter 23 mm; range 2-60 mm) and all were identified on MRI, with 90% of masses and 10% non-mass-like enhancements; MRI features significantly associated with ILC included absence of smooth margins (P = 0.02) and rim-shaped enhancement (P = 0.039). Enhancement kinetics of the 31 foci were evenly distributed among wash-out, plateau, and persistent profiles. Eleven additional lesions were seen on MRI, mainly corresponding to fibrocystic disease; 91% presented as masses and 9% had a wash-out profile. Conclusion: Based on the 2006 BI-RADS criteria, breast MRI shows a high sensitivity for ILC detection, at the expense of a 26% false-positive rate, suggesting that a pathological proof by US- or MR

  4. Magnetic Resonance Imaging (MRI and Spectroscopy (MRS in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Uma Sharma

    2008-01-01

    Full Text Available Breast cancer is a major health problem in women and early detection is of prime importance. Breast magnetic resonance imaging (MRI provides both physical and physiologic tissue features that are useful in discriminating malignant from benign lesions. Contrast enhanced MRI is valuable for diagnosis of small tumors in dense breast and the structural and kinetic parameters improved the specificity of diagnosing benign from malignant lesions. It is a complimentary modality for preoperative staging, to follow response to therapy, to detect recurrences and for screening high risk women. Diffusion, perfusion and MR elastography have been applied to breast lesion characterization and show promise.In-vivo MR spectroscopy (MRS is a valuable method to obtain the biochemical status of normal and diseased tissues. Malignant tissues contain high concentration of choline containing compounds that can be used as a biochemical marker. MRS helps to increase the specificity of MRI in lesions larger than 1cm and to monitor the tumor response. Various MR techniques show promise primarily as adjunct to the existing standard detection techniques, and its acceptability as a screening method will increase if specificity can be improved. This review presents the progress made in different MRI and MRS techniques in breast cancer management.

  5. Computerized Interpretation of Dynamic Breast MRI

    Science.gov (United States)

    2005-05-01

    The interpretation criteria in the current literature fall Breast MRI has emerged as a promising modality for the into two major categories: 5’ 14...is that theraphy , current interpretation schemes might not be sufficiently ro- Despite its well-recognized advantages, applications of bust. MRI in...postcontrast series For the manual delineation, a radiologist (U.B.), blinded were then taken with a time interval of 60 s. Each series to the histological

  6. Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent

    International Nuclear Information System (INIS)

    Davis, P.L.; McCarty, K.S. Jr.

    1997-01-01

    Magnetic resonance imaging (MRI) of the breast brings the advantages of high resolution cross-sectional imaging to breast cancer diagnosis, treatment and research: improved cancer detection, staging, selection of therapy, evaluation of therapeutic response in vivo, detection of recurrence, and even the development of new therapies. Until now breast cancer treatment and research has been impeded by the limited means of evaluating the breast cancer in vivo: primarily clinical palpation and mammography of the breast tumor. A review of the initial studies shows that with the use of paramagnetic contrast agents, MRI has a sensitivity of 96 % for detecting breast cancers. MRI detects multicentric disease with a sensitivity of 98 %, superior to any other modality. The ability of MRI to detect recurrent local breast cancer in the conservatively treated breast is nearly 100 %. MRI is capable of monitoring tumor response to chemotherapy and actually guiding therapeutic interventions such as interstitial laser photocoagulation. (orig.)

  7. MRI of the Breast for the Detection and Assessment of the Size of Ductal Carcinoma in Situ

    International Nuclear Information System (INIS)

    Kim, Do Youn; Moon, Woo Kyung; Cho, Nariya

    2007-01-01

    The aim of the study was to compare the accuracy of magnetic resonance imaging (MRI) and mammography for the detection and assessment of the size of ductal carcinoma in situ (DCIS). The preoperative contrast-enhanced MRI and mammography were analyzed in respect of the detection and assessment of the size of DCIS in 72 patients (age range: 30 67 years, mean age: 47 years). The MRI and mammographic measurements were compared with the histopathologic size with using the Pearson's correlation coefficients and the Mann-Whitney u test. We evaluated whether the breast density, the tumor nuclear grade, the presence of comedo necrosis and microinvasion influenced the MRI and mammographic size estimates by using the chi-square test. Of the 72 DCIS lesions, 68 (94%) were detected by MRI and 62 (86%) were detected by mammography. Overall, the Pearson's correlation of the size between MRI and histopathology was 0.786 versus 0.633 between mammography and histopathology (p < 0.001). MRI underestimated the size by more than 1 cm (including false negative examination) in 12 patients (17%), was accurate in 52 patients (72%) and overestimated the size by more than 1 cm in eight patients (11%) whereas mammography underestimated the size in 25 patients (35%), was accurate in 31 patients (43%) and overestimated the size in 16 patients (22%). The MRI, but not the mammography, showed significant correlation for the assessment of the size of tumor in noncomedo DCIS (p < 0.001 vs p = 0.060). The assessment of tumor size by MRI was affected by the nuclear grade (p = 0.008) and the presence of comedo necrosis (p = 0.029), but not by the breast density (p 0.747) or microinvasion (p = 0.093). MRI was more accurate for the detection and assessment of the size of DCIS than mammography

  8. Travel Burden to Breast MRI and Utilization: Are Risk and Sociodemographics Related?

    Science.gov (United States)

    Onega, Tracy; Lee, Christoph I; Benkeser, David; Alford-Teaster, Jennifer; Haas, Jennifer S; Tosteson, Anna N A; Hill, Deirdre; Shi, Xun; Henderson, Louise M; Hubbard, Rebecca A

    2016-06-01

    Mammography, unlike MRI, is relatively geographically accessible. Additional travel time is often required to access breast MRI. However, the amount of additional travel time and whether it varies on the basis of sociodemographic or breast cancer risk factors is unknown. The investigators examined screening mammography and MRI between 2005 and 2012 in the Breast Cancer Surveillance Consortium by (1) travel time to the closest and actual mammography facility used and the difference between the two, (2) women's breast cancer risk factors, and (3) sociodemographic characteristics. Logistic regression was used to examine the odds of traveling farther than the closest facility in relation to women's characteristics. Among 821,683 screening mammographic examinations, 76.6% occurred at the closest facility, compared with 51.9% of screening MRI studies (n = 3,687). The median differential travel time among women not using the closest facility for mammography was 14 min (interquartile range, 8-25 min) versus 20 min (interquartile range, 11-40 min) for breast MRI. Differential travel time for both imaging modalities did not vary notably by breast cancer risk factors but was significantly longer for nonurban residents. For non-Hispanic black compared with non-Hispanic white women, the adjusted odds of traveling farther than the closest facility were 9% lower for mammography (odds ratio, 0.91; 95% confidence interval, 0.87-0.95) but more than two times higher for MRI (odds ratio, 2.64; 95% confidence interval, 1.36-5.13). Breast cancer risk factors were not related to excess travel time for screening MRI, but sociodemographic factors were, suggesting the possibility that geographic distribution of advanced imaging may exacerbated disparities for some vulnerable populations. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Preoperative breast MRI in patients with invasive lobular breast cancer

    International Nuclear Information System (INIS)

    Schelfout, K.; Colpaert, C.; Van Goethem, M.; Verslegers, I.; Biltjes, I.; De Schepper, A.; Kersschot, E.; Leyman, P.; Thienpont, L.; Van den Haute, J.; Gillardin, J.P.; Tjalma, W.; Buytaert, Ph.

    2004-01-01

    To investigate the use of MRI in preoperative characterization of invasive lobular breast cancer (ILC) and in detection of multifocal/multicentric disease. We retrospectively reviewed T1-weighted FLASH 3D precontrast and postcontrast MR images together with subtraction images of 26 women with histopathologically proven invasive lobular cancer. Two experienced radiologists described tumor patterns of ILC independently. MR findings of unifocal, multifocal, single quadrant and multiquadrant disease were correlated with results of other imaging techniques and compared with histopathological findings as gold standard. Most ILC presented on MRI as a single spiculated/irregular, inhomogeneous mass (pattern 1, n=12) or as a dominant lesion surrounded by multiple small enhancing foci (pattern 2, n=8). Multiple small enhancing foci with interconnecting enhancing strands (pattern 3) and an architectural distortion (pattern 4) were both described in three cases. There was one case of a focal area of inhomogeneous enhancement (pattern 5) and one normal MR examination (pattern 6). Unifocal and multifocal lesions were identified on MRI in four patients with normal conventional imaging. In nine women, multiple additional lesions or more extensive multiquadrant disease were correctly identified only on MRI. MRI may play an important role in the evaluation of patients with ILC, which is often difficult to diagnose on clinical examination and conventional imaging and more likely occur in multiple sites and in both breasts. However, false-negative MR findings do occur in a small percentage of ILC. (orig.)

  10. Preoperative breast MRI in patients with invasive lobular breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schelfout, K.; Colpaert, C. [Department of Pathology, University Hospital Antwerp, Wilrijkstraat 10, 2650, Edegem (Belgium); Van Goethem, M.; Verslegers, I.; Biltjes, I.; De Schepper, A. [Department of Radiology, University Hospital Antwerp, Wilrijkstraat 10, 2650, Edegem (Belgium); Kersschot, E.; Leyman, P. [Department of Radiology, O.L.V. Hospital Aalst, Moorselbaan 164, 9000, Aalst (Belgium); Thienpont, L. [Department of Pathology, O.L.V. Hospital Aalst, Moorselbaan 164, 9000, Aalst (Belgium); Van den Haute, J. [Department of Gynecology, O.L.V. Hospital Aalst, Moorselbaan 164, 9000, Aalst (Belgium); Gillardin, J.P. [Department of Surgery, O.L.V. Hospital Aalst, Moorselbaan 164, 9000, Aalst (Belgium); Tjalma, W.; Buytaert, Ph. [Department of Gynecology, University Hospital Antwerp, Wilrijkstraat 10, 2650, Edegem (Belgium)

    2004-07-01

    To investigate the use of MRI in preoperative characterization of invasive lobular breast cancer (ILC) and in detection of multifocal/multicentric disease. We retrospectively reviewed T1-weighted FLASH 3D precontrast and postcontrast MR images together with subtraction images of 26 women with histopathologically proven invasive lobular cancer. Two experienced radiologists described tumor patterns of ILC independently. MR findings of unifocal, multifocal, single quadrant and multiquadrant disease were correlated with results of other imaging techniques and compared with histopathological findings as gold standard. Most ILC presented on MRI as a single spiculated/irregular, inhomogeneous mass (pattern 1, n=12) or as a dominant lesion surrounded by multiple small enhancing foci (pattern 2, n=8). Multiple small enhancing foci with interconnecting enhancing strands (pattern 3) and an architectural distortion (pattern 4) were both described in three cases. There was one case of a focal area of inhomogeneous enhancement (pattern 5) and one normal MR examination (pattern 6). Unifocal and multifocal lesions were identified on MRI in four patients with normal conventional imaging. In nine women, multiple additional lesions or more extensive multiquadrant disease were correctly identified only on MRI. MRI may play an important role in the evaluation of patients with ILC, which is often difficult to diagnose on clinical examination and conventional imaging and more likely occur in multiple sites and in both breasts. However, false-negative MR findings do occur in a small percentage of ILC. (orig.)

  11. Three-dimensional vascular mapping of the breast by using contrast-enhanced MRI: association of unilateral increased vascularity with ipsilateral breast cancer.

    Science.gov (United States)

    Orgüç, Şebnem; Başara, Işıl; Coşkun, Teoman; Pekindil, Gökhan

    2012-01-01

    We aimed to retrospectively compare three-dimensional vascular maps of both breasts obtained by dynamic magnetic resonance imaging (MRI) and determine the association of one-sided vascular prominence with ipsilateral breast cancer. MRI was performed using gadolinium in 194 cases. Two readers scored vascular density using maximum intensity projections (MIPs). Dynamic fat-saturated T1-weighted gradientecho MIPs were acquired. Two readers evaluated the MIPs, and vessels greater than 2 mm in diameter and longer than 3 cm were counted. The difference in vessel numbers detected in the two breasts determined the score. A total of 54 patients had malignant lesions (prevalence, 28%), including invasive ductal carcinoma (n=40), invasive mixed ductal-lobular carcinoma (n=5), invasive lobular carcinoma (n=3), ductal carcinoma in situ (n=3), mucinous carcinoma (n=1), medullary carcinoma (n=1), and leukemic metastasis (n=1). In 62 patients, there were benign lesions (fibroadenomas, fibrocysts), and four patients had inflammation (granulomatous mastitis in two patients, breast tuberculosis in two patients). There were 78 normal cases. When a difference of at least two vessels was scored as vascular asymmetry, the sensitivity, specificity, positive likelihood ratio (+LR), and negative (-LR) of unilaterally increased vascularity associated with ipsilateral malignancy were 69%, 92%, 8.72, and 0.34, respectively. When four infection and three post-operative cases with vascular asymmetry were excluded; prevalence, specificity, and +LR increased to 29%, 97%, and 22.8, respectively, with the same sensitivity and -LR. Differences in mean vascularity scores were evaluated with regard to tumor size. T1 and T2 tumors were not significantly different from each other. The mean score of T3 tumors differed significantly from T1 and T2 tumors. MRI vascular mapping is an effective method for determining breast tissue vascularization. Ipsilateral increased vascularity was commonly associated with

  12. Usefulness of breast MRI for diagnosing an extensive intraductal component of breast cancer: comparison with mammography and ultrasonography

    International Nuclear Information System (INIS)

    Kim, Tae Hee; Kang, Doo Kyung; Jung, Yong Sik; Yim, Hyun Ee

    2006-01-01

    An extensive intraductal component of breast cancer is a principal risk factor for local recurrence, and this is difficult to diagnose with performing only mammography. We investigated the usefulness of breast MRI for evaluating an extensive intraductal component of breast cancer, and we compared this modality with mammography and ultrasonography (US). From March 2003 to July 2004, 90 patients underwent breast MRI among all the patients who were suffering with breast cancer and for whom and EIC was ultimately revealed to be present or not. A total 83 patients with stage I and II breast cancer were finally included in this study. EIC positivity was defined according to the imaging data as follows: 1) microcalcifications beyond the tumor shadow or malignant microcalcifications without a tumor mass on mammography, 2) tubular hypoechoic structures adjacent to the tumor or architectural distortion with calcifications beyond the tumor on US, and 3) linear or ductal enhancement, segmental or regional clumped enhancement, and spotty nodular or reticular enhancement adjacent to the tumor on MRI. EIC was present in 41 patients and this finding was negative in 42 patients. The results were then compared those results from mammography and US. The sensitivities of detecting EIC by mammography, US and MRI were 48.6%, 67.5% and 80.5%, respectively, and the corresponding specificities were 92.3%, 73.2% and 69.0%, respectively. In the cases that were suspected to be EIC positive on more than two imaging modality, the positive predictive value (PPV) was 78.1%. In cases that were suspected of being EIC positive on just one imaging modality, the negative predictive value (NPV) was 75.0%. Breast MRI provides good information about an EIC of breast cancer and it is a more sensitive study than mammography and US, yet the specificity for the detection of EIC is highest on mammography. A combined evaluation by mammography, US and MRI is the most accurate way to diagnose an EIC of breast

  13. Breast Density and Risk of Breast Cancer in Asian Women: A Meta-analysis of Observational Studies.

    Science.gov (United States)

    Bae, Jong-Myon; Kim, Eun Hee

    2016-11-01

    The established theory that breast density is an independent predictor of breast cancer risk is based on studies targeting white women in the West. More Asian women than Western women have dense breasts, but the incidence of breast cancer is lower among Asian women. This meta-analysis investigated the association between breast density in mammography and breast cancer risk in Asian women. PubMed and Scopus were searched, and the final date of publication was set as December 31, 2015. The effect size in each article was calculated using the interval-collapse method. Summary effect sizes (sESs) and 95% confidence intervals (CIs) were calculated by conducting a meta-analysis applying a random effect model. To investigate the dose-response relationship, random effect dose-response meta-regression (RE-DRMR) was conducted. Six analytical epidemiology studies in total were selected, including one cohort study and five case-control studies. A total of 17 datasets were constructed by type of breast density index and menopausal status. In analyzing the subgroups of premenopausal vs. postmenopausal women, the percent density (PD) index was confirmed to be associated with a significantly elevated risk for breast cancer (sES, 2.21; 95% CI, 1.52 to 3.21; I 2 =50.0%). The RE-DRMR results showed that the risk of breast cancer increased 1.73 times for each 25% increase in PD in postmenopausal women (95% CI, 1.20 to 2.47). In Asian women, breast cancer risk increased with breast density measured using the PD index, regardless of menopausal status. We propose the further development of a breast cancer risk prediction model based on the application of PD in Asian women.

  14. Early prediction of the response of breast tumors to neoadjuvant chemotherapy using quantitative MRI and machine learning.

    Science.gov (United States)

    Mani, Subramani; Chen, Yukun; Arlinghaus, Lori R; Li, Xia; Chakravarthy, A Bapsi; Bhave, Sandeep R; Welch, E Brian; Levy, Mia A; Yankeelov, Thomas E

    2011-01-01

    The ability to predict early in the course of treatment the response of breast tumors to neoadjuvant chemotherapy can stratify patients based on response for patient-specific treatment strategies. Currently response to neoadjuvant chemotherapy is evaluated based on physical exam or breast imaging (mammogram, ultrasound or conventional breast MRI). There is a poor correlation among these measurements and with the actual tumor size when measured by the pathologist during definitive surgery. We tested the feasibility of using quantitative MRI as a tool for early prediction of tumor response. Between 2007 and 2010 twenty consecutive patients diagnosed with Stage II/III breast cancer and receiving neoadjuvant chemotherapy were enrolled on a prospective imaging study. Our study showed that quantitative MRI parameters along with routine clinical measures can predict responders from non-responders to neoadjuvant chemotherapy. The best predictive model had an accuracy of 0.9, a positive predictive value of 0.91 and an AUC of 0.96.

  15. Breast density quantification with cone-beam CT: a post-mortem study

    International Nuclear Information System (INIS)

    Johnson, Travis; Ding, Huanjun; Le, Huy Q; Ducote, Justin L; Molloi, Sabee

    2013-01-01

    Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The per cent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson's r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. (paper)

  16. Fully automated deformable registration of breast DCE-MRI and PET/CT

    Science.gov (United States)

    Dmitriev, I. D.; Loo, C. E.; Vogel, W. V.; Pengel, K. E.; Gilhuijs, K. G. A.

    2013-02-01

    Accurate characterization of breast tumors is important for the appropriate selection of therapy and monitoring of the response. For this purpose breast imaging and tissue biopsy are important aspects. In this study, a fully automated method for deformable registration of DCE-MRI and PET/CT of the breast is presented. The registration is performed using the CT component of the PET/CT and the pre-contrast T1-weighted non-fat suppressed MRI. Comparable patient setup protocols were used during the MRI and PET examinations in order to avoid having to make assumptions of biomedical properties of the breast during and after the application of chemotherapy. The registration uses a multi-resolution approach to speed up the process and to minimize the probability of converging to local minima. The validation was performed on 140 breasts (70 patients). From a total number of registration cases, 94.2% of the breasts were aligned within 4.0 mm accuracy (1 PET voxel). Fused information may be beneficial to obtain representative biopsy samples, which in turn will benefit the treatment of the patient.

  17. Endocrine determinants of breast density and breast cancer

    NARCIS (Netherlands)

    Verheus, M.

    2007-01-01

    Worldwide, breast cancer is the most common malignancy among females. The total breast area on a mammogram can be dived in a radiologicaly dense area (glandular and stromal tissue) and a non-dense area (mainly fat tissue). Women with a high proportion of dense breast tissue (percent breast density)

  18. A deep learning method for classifying mammographic breast density categories.

    Science.gov (United States)

    Mohamed, Aly A; Berg, Wendie A; Peng, Hong; Luo, Yahong; Jankowitz, Rachel C; Wu, Shandong

    2018-01-01

    Mammographic breast density is an established risk marker for breast cancer and is visually assessed by radiologists in routine mammogram image reading, using four qualitative Breast Imaging and Reporting Data System (BI-RADS) breast density categories. It is particularly difficult for radiologists to consistently distinguish the two most common and most variably assigned BI-RADS categories, i.e., "scattered density" and "heterogeneously dense". The aim of this work was to investigate a deep learning-based breast density classifier to consistently distinguish these two categories, aiming at providing a potential computerized tool to assist radiologists in assigning a BI-RADS category in current clinical workflow. In this study, we constructed a convolutional neural network (CNN)-based model coupled with a large (i.e., 22,000 images) digital mammogram imaging dataset to evaluate the classification performance between the two aforementioned breast density categories. All images were collected from a cohort of 1,427 women who underwent standard digital mammography screening from 2005 to 2016 at our institution. The truths of the density categories were based on standard clinical assessment made by board-certified breast imaging radiologists. Effects of direct training from scratch solely using digital mammogram images and transfer learning of a pretrained model on a large nonmedical imaging dataset were evaluated for the specific task of breast density classification. In order to measure the classification performance, the CNN classifier was also tested on a refined version of the mammogram image dataset by removing some potentially inaccurately labeled images. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to measure the accuracy of the classifier. The AUC was 0.9421 when the CNN-model was trained from scratch on our own mammogram images, and the accuracy increased gradually along with an increased size of training samples

  19. Heterogeneity wavelet kinetics from DCE-MRI for classifying gene expression based breast cancer recurrence risk.

    Science.gov (United States)

    Mahrooghy, Majid; Ashraf, Ahmed B; Daye, Dania; Mies, Carolyn; Feldman, Michael; Rosen, Mark; Kontos, Despina

    2013-01-01

    Breast tumors are heterogeneous lesions. Intra-tumor heterogeneity presents a major challenge for cancer diagnosis and treatment. Few studies have worked on capturing tumor heterogeneity from imaging. Most studies to date consider aggregate measures for tumor characterization. In this work we capture tumor heterogeneity by partitioning tumor pixels into subregions and extracting heterogeneity wavelet kinetic (HetWave) features from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to obtain the spatiotemporal patterns of the wavelet coefficients and contrast agent uptake from each partition. Using a genetic algorithm for feature selection, and a logistic regression classifier with leave one-out cross validation, we tested our proposed HetWave features for the task of classifying breast cancer recurrence risk. The classifier based on our features gave an ROC AUC of 0.78, outperforming previously proposed kinetic, texture, and spatial enhancement variance features which give AUCs of 0.69, 0.64, and 0.65, respectively.

  20. Breast tumor characteristics of BRCA1 and BRCA2 gene mutation carriers on MRI

    International Nuclear Information System (INIS)

    Veltman, J.; Mann, R.; Blickman, J.G.; Boetes, C.; Kok, T.; Obdeijn, I.M.; Hoogerbrugge, N.

    2008-01-01

    The appearance of malignant lesions in BRCA1 and BRCA2 mutation carriers (BRCA-MCs) on mammography and magnetic resonance imaging (MRI) was evaluated. Thus, 29 BRCA-MCs with breast cancer were retrospectively evaluated and the results compared with an age, tumor size and tumor type matched control group of 29 sporadic breast cancer cases. Detection rates on both modalities were evaluated. Tumors were analyzed on morphology, density (mammography), enhancement pattern and kinetics (MRI). Overall detection was significantly better with MRI than with mammography (55/58 vs 44/57, P = 0.021). On mammography, lesions in the BRCA-MC group were significantly more described as rounded (12//19 vs 3/13, P = 0.036) and with sharp margins (9/19 vs 1/13, P 0.024). On MRI lesions in the BRCA-MC group were significantly more described as rounded (16/27 vs 7/28, P = 0.010), with sharp margins (20/27 vs 7/28, P < 0.001) and with rim enhancement (7/27 vs 1/28, P = 0.025). No significant difference was found for enhancement kinetics (P = 0.667). Malignant lesions in BRCA-MC frequently have morphological characteristics commonly seen in benign lesions, like a rounded shape or sharp margins. This applies for both mammography and MRI. However the possibility of MRI to evaluate the enhancement pattern and kinetics enables the detection of characteristics suggestive for a malignancy. (orig.)

  1. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    Science.gov (United States)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  2. MRI and mammography surveillance of women at increased risk for breast cancer: recommendations using an evidence-based approach.

    Science.gov (United States)

    Granader, Elon J; Dwamena, Ben; Carlos, Ruth C

    2008-12-01

    To evaluate breast cancer screening with mammography and magnetic resonance imaging (MRI) in high-risk populations, including women with the BRCA mutation, using an evidence-based approach. The MEDLINE, PubMed, EBM Reviews, ACP Journal Club, Cochrane Database MEDSEARCH, and SCOPUS databases were accessed and searched for articles up to August 2007. Articles were collected using the following terms and medical subject headings (MeSH) that applied to the focused clinical question: "BRCA1" and "BRCA2" with "mammography," "MRI," "prevention," "screening," and "surveillance." References from retrieved articles were also used to identify relevant papers. Abstracts were screened and relevant papers retrieved. Retrieved papers were graded for quality. Summary performance measures were obtained by random effects modeling of study-specific performance estimates and standard errors derived from the multiple 2 x 2 tables. Additionally, studies meeting the Centre for Evidence-Based Medicine level 2b quality were reviewed. In women with an increased risk without the BRCA gene, cancer detection rates by MRI were 0.011 (95% confidence interval [CI] 0.003-0.019), by mammography 0.005 (95% CI 0.002-0.008), and by a combination of both, 0.012 (95% CI 0.004-0.020). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.03-0.18), 0.05 (95% CI 0.03-0.06), and 0.14 (95% CI 0.04-0.24). In BRCA positive women, cancer detection rates by MRI were 0.027 (95% CI 0.015-0.040), by mammography 0.010 (95% CI 0.005-0.016), and by a combination of both 0.031 (95% CI 0.018-0.045). False-positive rates by MRI, mammography, or a combination of both were 0.10 (95% CI 0.01-0.19), 0.05 (95% CI 0.03-0.07), and 0.14 (95% CI 0.04-0.24), respectively. The data support an essential role for screening MRI in women with an increased risk for breast cancer.

  3. Comparison of imaging diagnosis of pyogenic abscess and inflammatory cancer in the breast: focused on MRI

    International Nuclear Information System (INIS)

    Ko, Mi Gyoung; Chung, Soo Young; Yang, Ik; Park, Jong Ho; Lee, Kyung Won; Lee, Yul; Chung, Bong Wha; Kim, Jong Hyun

    1999-01-01

    To compare the radiologic findings of pyogenic abscess(PA) and inflammatory cancer(IC) of the breast, as seen on mammograms, US, and MR images and to evaluate the usefulness of the differential diagnostic findings of MRI for differentiation of PA and IC of the breast. We retrospectively analyzed the mammographic, US and MR findings of nine histopathologically proven cases of PA and four cases of IC of the breast . Parenchymal density, mass density, skin thickening and calcification were evaluated by mammography, and the extent of lesion and its morphologic characteristics and changes of dermal lymphatics by US and MRI. The latter was also used to analyse signal intensity and enhancement pattern. Mammographic findings for both lesions were non-specific. US showed that the pyogenic abscess was a hypoechoic and anechoic complex lesion with posterior acoustic enhancement, while inflammatory cancer was a speculated lesion with a heterogeneous hypoechoic echotexture. On 3D-GRE dynamic enhanced MRI, PA was shown in six cases(66.7 %) to be a lesion with superficial periareolar involvement, in contrast to the deep parenchymal spread seen in all cases of IC. A central non-enhanced portion with an irregular thick peripheral enhanced rim was seen in eight cases of PA(88.9 %), and in all cases of IC an inhomogeneously enhanced spiculated lesion in parenchyma and a diffusely enhanced dermal and subcutaneous layer was apparent. An MRI time-intensity curve showed that the enhancement pattern was slow in five cases of PA(55.6 %) and irregular in four(44.4 %), while for IC it was rapid in three cases(33.3 %) and irregular in one(11.1 %). As compared with mammography and US, 3D-GRE dynamic MRI was a useful method for the differential diagnosis of PA and IC of the breast. The characteristic MR findings of PA were a central non-enhanced portion with an irregularly thick peripheral enhanced rim, located mainly in the superficial periareloar area and spreading into the parenchymal layer

  4. Comparison of imaging diagnosis of pyogenic abscess and inflammatory cancer in the breast: focused on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Mi Gyoung; Chung, Soo Young; Yang, Ik; Park, Jong Ho; Lee, Kyung Won; Lee, Yul; Chung, Bong Wha; Kim, Jong Hyun [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-09-01

    To compare the radiologic findings of pyogenic abscess(PA) and inflammatory cancer(IC) of the breast, as seen on mammograms, US, and MR images and to evaluate the usefulness of the differential diagnostic findings of MRI for differentiation of PA and IC of the breast. We retrospectively analyzed the mammographic, US and MR findings of nine histopathologically proven cases of PA and four cases of IC of the breast . Parenchymal density, mass density, skin thickening and calcification were evaluated by mammography, and the extent of lesion and its morphologic characteristics and changes of dermal lymphatics by US and MRI. The latter was also used to analyse signal intensity and enhancement pattern. Mammographic findings for both lesions were non-specific. US showed that the pyogenic abscess was a hypoechoic and anechoic complex lesion with posterior acoustic enhancement, while inflammatory cancer was a speculated lesion with a heterogeneous hypoechoic echotexture. On 3D-GRE dynamic enhanced MRI, PA was shown in six cases(66.7 %) to be a lesion with superficial periareolar involvement, in contrast to the deep parenchymal spread seen in all cases of IC. A central non-enhanced portion with an irregular thick peripheral enhanced rim was seen in eight cases of PA(88.9 %), and in all cases of IC an inhomogeneously enhanced spiculated lesion in parenchyma and a diffusely enhanced dermal and subcutaneous layer was apparent. An MRI time-intensity curve showed that the enhancement pattern was slow in five cases of PA(55.6 %) and irregular in four(44.4 %), while for IC it was rapid in three cases(33.3 %) and irregular in one(11.1 %). As compared with mammography and US, 3D-GRE dynamic MRI was a useful method for the differential diagnosis of PA and IC of the breast. The characteristic MR findings of PA were a central non-enhanced portion with an irregularly thick peripheral enhanced rim, located mainly in the superficial periareloar area and spreading into the parenchymal layer

  5. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size

    International Nuclear Information System (INIS)

    Fallenberg, E.M.; Renz, D.M.; Dromain, C.; Diekmann, F.; Engelken, F.; Krohn, M.; Singh, J.M.; Bick, U.; Ingold-Heppner, B.; Winzer, K.J.

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. (orig.)

  6. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size

    Energy Technology Data Exchange (ETDEWEB)

    Fallenberg, E.M.; Renz, D.M. [Charite - Universitaetsmedizin Berlin, Clinic of Radiology, Berlin (Germany); Dromain, C. [Institut Gustave Roussy, Department of Radiology, Villejuif cedex (France); Diekmann, F. [St. Joseph-Stift Bremen, Department of Medical Imaging, Bremen (Germany); Engelken, F.; Krohn, M.; Singh, J.M.; Bick, U. [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Ingold-Heppner, B. [Charite - Universitaetsmedizin Berlin, Institute of Pathology, Berlin (Germany); Winzer, K.J. [Charite - Universitaetsmedizin Berlin, Breast Center, Department of Gynecology, Berlin (Germany)

    2014-01-15

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. (orig.)

  7. Magnetic Resonance Imaging (MRI and Spectroscopy (MRS in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Uma Sharma

    2008-01-01

    Full Text Available Breast cancer is a major health problem in women and early detection is of prime importance. Breast magnetic resonance imaging (MRI provides both physical and physiologic tissue features that are useful in discriminating malignant from benign lesions. Contrast enhanced MRI is valuable for diagnosis of small tumors in dense breast and the structural and kinetic parameters improved the specificity of diagnosing benign from malignant lesions. It is a complimentary modality for preoperative staging, to follow response to therapy, to detect recurrences and for screening high risk women. Diffusion, perfusion and MR elastography have been applied to breast lesion characterization and show promise. In-vivo MR spectroscopy (MRS is a valuable method to obtain the biochemical status of normal and diseased tissues. Malignant tissues contain high concentration of choline containing compounds that can be used as a biochemical marker. MRS helps to increase the specificity of MRI in lesions larger than 1cm and to monitor the tumor response. Various MR techniques show promise primarily as adjunct to the existing standard detection techniques, and its acceptability as a screening method will increase if specificity can be improved. This review presents the progress made in different MRI and MRS techniques in beast cancer management.

  8. A Cost Analysis of Preoperative Breast MRI Use for Patients with Invasive Lobular Cancer.

    Science.gov (United States)

    Bedrosian, Isabelle; Xing, Yan; Abdel Rahman, Shereen; Allen, Lisa; Le-Petross, Huong; Whitman, Gary J; Meric-Bernstam, Funda; Hunt, Kelly K; Babiera, Gildy V; Cormier, Janice N

    2016-01-01

    Whereas the impact of magnetic resonance imaging (MRI) of the breast on the surgical management of breast cancer patients is well documented, less is known about its effect on health care costs. This study aimed to evaluate whether MRI use for women with invasive lobular carcinoma (ILC) significantly changes the cost of care. Patients with ILC were recruited to a prospective registry study of breast MRI. Women who met the same inclusion criteria but had not undergone breast MRI were retrospectively identified for comparison. A micro-costing analysis using institutional billing records was conducted. Nonparametric bootstrapping was used to compare the unadjusted cost differences between the patients receiving MRI and those receiving no MRI. Of the patients in this study, 51 had preoperative MRI, and 60 did not. Method of diagnostic biopsy, disease stage, oncologic procedure, and rates of contralateral prophylactic mastectomy were similar between the two groups. The patients in the MRI group were younger (median age 55 vs. 64 years; p = 0.01) and more likely to undergo reconstruction (45.1 vs. 25 %; p = 0.03). The median costs of care were significantly higher in the MRI group ($24,781 vs. $18,921; p 1; p < 0.01), and use of reconstruction (p < 0.01). Preoperative breast MRI increases the median total cost of care per patient. However, the contribution to the overall cost of care is modest compared with the cost of other interventions.

  9. A simple classification system (the Tree flowchart) for breast MRI can reduce the number of unnecessary biopsies in MRI-only lesions

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Spick, Claudio; Schernthaner, Melanie; Kapetas, Panagiotis; Bernathova, Maria; Furtner, Julia; Pinker, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T. [Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Clinical Institute of Pathology, Vienna (Austria)

    2017-09-15

    To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our institution for MRI-guided biopsy. All lesions were evaluated according to the Tree flowchart for breast MRI by experienced readers. The Tree flowchart is a decision rule that assigns levels of suspicion to specific combinations of diagnostic criteria. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic accuracy. To assess reproducibility by kappa statistics, a second reader rated a subset of 82 patients. There were 454 patients with 469 histopathologically verified lesions included (98 malignant, 371 benign lesions). The area under the curve (AUC) of the Tree flowchart was 0.873 (95% CI: 0.839-0.901). The inter-reader agreement was almost perfect (kappa: 0.944; 95% CI 0.889-0.998). ROC analysis revealed exclusively benign lesions if the Tree node was ≤2, potentially avoiding unnecessary biopsies in 103 cases (27.8%). Using the Tree flowchart in breast lesions only visible on MRI, more than 25% of biopsies could be avoided without missing any breast cancer. (orig.)

  10. Radiomics for ultrafast dynamic contrast-enhanced breast MRI in the diagnosis of breast cancer: a pilot study

    Science.gov (United States)

    Drukker, Karen; Anderson, Rachel; Edwards, Alexandra; Papaioannou, John; Pineda, Fred; Abe, Hiroyuke; Karzcmar, Gregory; Giger, Maryellen L.

    2018-02-01

    Radiomics for dynamic contrast-enhanced (DCE) breast MRI have shown promise in the diagnosis of breast cancer as applied to conventional DCE-MRI protocols. Here, we investigate the potential of using such radiomic features in the diagnosis of breast cancer applied on ultrafast breast MRI in which images are acquired every few seconds. The dataset consisted of 64 lesions (33 malignant and 31 benign) imaged with both `conventional' and ultrafast DCE-MRI. After automated lesion segmentation in each image sequence, we calculated 38 radiomic features categorized as describing size, shape, margin, enhancement-texture, kinetics, and enhancement variance kinetics. For each feature, we calculated the 95% confidence interval of the area under the ROC curve (AUC) to determine whether the performance of each feature in the task of distinguishing between malignant and benign lesions was better than random guessing. Subsequently, we assessed performance of radiomic signatures in 10-fold cross-validation repeated 10 times using a support vector machine with as input all the features as well as features by category. We found that many of the features remained useful (AUC>0.5) for the ultrafast protocol, with the exception of some features, e.g., those designed for latephase kinetics such as the washout rate. For ultrafast MRI, the radiomics enhancement-texture signature achieved the best performance, which was comparable to that of the kinetics signature for `conventional' DCE-MRI, both achieving AUC values of 0.71. Radiomic developed for `conventional' DCE-MRI shows promise for translation to the ultrafast protocol, where enhancement texture appears to play a dominant role.

  11. Angiogenesis and dynamic contrast enhanced MRI of benign and malignant breast lesions: preliminary results

    International Nuclear Information System (INIS)

    Liu Peifang; Bao Runxian; Niu Yun; Yu Yong

    2002-01-01

    Objective: To determine whether dynamic contrast enhanced MRI features of early-phase enhancement rate, enhancement amplitude, and signal intensity (SI) time course are associated with the microvessel density (MVD) and vascular endothelial growth factor (VEGF) expression of malignant and benign breast lesions. Methods: Thirty-eight patients with histopathologically verified breast lesions underwent dynamic contrast enhanced MRI. SI changes during dynamic scanning were assessed quantitatively. Early-phase enhancement rate and enhancement amplitude were calculated. Time-SI curves of the lesions were obtained and classified according to their shapes as type I (which was steady enhancement to the end of the dynamic data acquisition at 7.5 min), type II (plateau of SI after avid initial contrast enhancement), or type III (washout of SI after avid initial contrast enhancement). the mean MVD and VEGF expression of the lesions were measured with immuno-histochemical staining method in all the histologic specimens by pathologists without the knowledge of the results of the MR examination. The relationships among dynamic contrast enhanced MRI features, MVD, and VEGF expression of benign and malignant breast lesions were analyzed. Results: Histology revealed 21 malignancies and 17 benign lesions. The mean MVD and VEGF expression for 21 malignant lesions were statistically higher than the mean MVD and VEGF expression for 17 benign lesions. High VEGF expression of benign and malignant breast lesions showed an association with increased MVD. Among all 38 lesions, greater (> 60%) MR early-phase enhancement rate and time-SI curve type II and III showed an association with increased MVD and higher VEGF expression level. All the differences mentioned above showed statistical significance except that the difference between VEGF expression and the distribution of curve types had no statistical significance. No significant relationships were observed between the mean of enhancement

  12. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size.

    Science.gov (United States)

    Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.

  13. Breast density pattern characterization by histogram features and texture descriptors

    OpenAIRE

    Carneiro,Pedro Cunha; Franco,Marcelo Lemos Nunes; Thomaz,Ricardo de Lima; Patrocinio,Ana Claudia

    2017-01-01

    Abstract Introduction Breast cancer is the first leading cause of death for women in Brazil as well as in most countries in the world. Due to the relation between the breast density and the risk of breast cancer, in medical practice, the breast density classification is merely visual and dependent on professional experience, making this task very subjective. The purpose of this paper is to investigate image features based on histograms and Haralick texture descriptors so as to separate mammo...

  14. Hybrid 18F-FDG PET/MRI might improve locoregional staging of breast cancer patients prior to neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Goorts, Briete; Nijnatten, Thiemo J.A. van; Voeoe, Stefan; Wildberger, Joachim E.; Lobbes, Marc B.I.; Kooreman, Loes F.S.; Boer, Maaike de; Keymeulen, Kristien B.M.I.; Aarnoutse, Romy; Smidt, Marjolein L.; Mottaghy, Felix M.

    2017-01-01

    Our purpose in this study was to assess the added clinical value of hybrid 18 F-FDG-PET/MRI compared to conventional imaging for locoregional staging in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). In this prospective study, primary invasive cT2-4 N0 or cT1-4 N+ breast cancer patients undergoing NAC were included. A PET/MRI breast protocol was performed before treatment. MR images were evaluated by a breast radiologist, blinded for PET images. PET images were evaluated by a nuclear physician. Afterwards, a combined PET/MRI report was written. PET/MRI staging was compared to conventional imaging, i.e., mammography, ultrasound and MRI. The proportion of patients with a modified treatment plan based on PET/MRI findings was analyzed. A total of 40 patients was included. PET/MRI was of added clinical value in 20.0% (8/40) of patients, changing the treatment plan in 10% and confirming the malignancy of suspicious lesions on MRI in another 10%. In seven (17.5%) patients radiotherapy fields were extended because of additional or affirmative PET/MRI findings being lymph node metastases (n = 5) and sternal bone metastases (n = 2). In one (2.5%) patient radiotherapy fields were reduced because of fewer lymph node metastases on PET/MRI compared to conventional imaging. Interestingly, all treatment changes were based on differences in number of lymph nodes suspicious for metastasis or number of distant metastasis, whereas differences in intramammary tumor extent were not observed. Prior to NAC, PET/MRI shows promising results for locoregional staging compared to conventional imaging, changing the treatment plan in 10% of patients and potentially replacing PET/CT or tissue sampling in another 10% of patients. (orig.)

  15. Breast cancer screening effect across breast density strata: A case-control study.

    Science.gov (United States)

    van der Waal, Daniëlle; Ripping, Theodora M; Verbeek, André L M; Broeders, Mireille J M

    2017-01-01

    Breast cancer screening is known to reduce breast cancer mortality. A high breast density may affect this reduction. We assessed the effect of screening on breast cancer mortality in women with dense and fatty breasts separately. Analyses were performed within the Nijmegen (Dutch) screening programme (1975-2008), which invites women (aged 50-74 years) biennially. Performance measures were determined. Furthermore, a case-control study was performed for women having dense and women having fatty breasts. Breast density was assessed visually with a dichotomized Wolfe scale. Breast density data were available for cases. The prevalence of dense breasts among controls was estimated with age-specific rates from the general population. Sensitivity analyses were performed on these estimates. Screening performance was better in the fatty than in the dense group (sensitivity 75.7% vs 57.8%). The mortality reduction appeared to be smaller for women with dense breasts, with an odds ratio (OR) of 0.87 (95% CI 0.52-1.45) in the dense and 0.59 (95% CI 0.44-0.79) in the fatty group. We can conclude that high density results in lower screening performance and appears to be associated with a smaller mortality reduction. Breast density is thus a likely candidate for risk-stratified screening. More research is needed on the association between density and screening harms. © 2016 UICC.

  16. MRI of the breast: does the internet accurately report its beneficial uses and limitations?

    Science.gov (United States)

    Nekhlyudov, Larissa; Kiarsis, Keith; Elmore, Joann G

    2009-01-01

    As consumer use of the Internet for medical information grows, continuing evaluation of the medical content on the Internet is needed. We evaluated Internet sites describing breast magnetic resonance imaging (MRI), an emerging technology tool in breast cancer diagnosis and screening. We searched Google for sites describing breast MRI and abstracted the affiliation, content, media type, readability, and quality of 90 most popular unique sites. Over half (56%) of the sites were commercially sponsored. The content varied by site and included medical and procedural facts, information about clinical trials, grants and journal articles, as well as human interest stories. Most (82%) sites described potentially beneficial uses of breast MRI, such as further evaluation of newly diagnosed breast cancers (58%); screening women at high risk for breast cancer (54%); evaluation of abnormal breast findings (48%); screening women with dense breasts (48%) or implants (27%); and surveillance for breast cancer recurrences (24%). Approximately half (56%) of the sites described the limitations of breast MRI, most commonly false positive findings (44%) and costs (24%). Website quality, including the display of contact information, sponsorship, currency of information, authorship, and references varied. The reading level was close to high school graduate. Internet sites describing breast MRI were mostly commercially sponsored, more often described the potential beneficial uses of the procedure than its limitations, and were of variable quality and high reading level. With the lack of enforceable standards for display of medical information on the Internet, providers should encourage patients to direct their searches to the most credible sites.

  17. Breast MRI at 3.0 T in a high-risk familial breast cancer screening cohort: comparison with 1.5 T screening studies.

    Science.gov (United States)

    Pickles, M D; Turnbull, L W

    2012-07-01

    The sensitivity of X-ray mammography for the detection of breast malignancy in younger females is lower than that of breast MRI; consequently, guidelines recommend annual MRI for patients with a significantly elevated lifetime risk. The improved signal-to-noise ratio obtainable at 3.0 T should result in data superior to those obtainable at 1.5 T. However, breast imaging on higher field strength systems poses specific problems. As a result, caution has been urged in the implementation of breast MRI at 3.0 T. The aim of this study was to determine if it is appropriate to use 3.0 T MRI in the screening of patients by comparing the summary statistics achieved by this 3.0 T MRI programme against the published results of 1.5 T screening studies. Over a 20-month period, 291 patients referred with an elevated familial risk of breast cancer were examined at 3.0 T. Resulting images were scored based on the Royal College of Radiologists Breast Group imaging classification. The reference standard was a combination of histology and follow-up imaging. Follow-up data were available in 267 patients. Analysis revealed positive and negative post-test probabilities of 28% [95% confidence intervals (CI); range, 10-60%] and 1% (95% CI; range, 0-2%), respectively. These results compared favourably against those of a recent meta-analysis [25.3% (95% CI; range, 18.4-33.8%) and 0.4% (95% CI; range, 0.2-0.9%), respectively]. Given the similar summary statistics between this work and the 1.5 T results, it would appear that screening of high-risk patients at 3.0 T has potential. Further studies should be undertaken to verify this result.

  18. Statistical analysis of MRI-only based dose planning

    DEFF Research Database (Denmark)

    Korsholm, M. E.; Waring, L. W.; Paulsen, Rasmus Reinhold

    2012-01-01

    . MRIonly based RT eliminates these errors and reduce the time and costs of a CT scan. The aim of this study is to investigate the dosimetric differences of a treatment plan when the dose calculation is based on MRI as compared to CT. Materials and Methods: Four diagnostic groups are investigated; 12...... as a clinically approved treatment plan. The treatment planning software is Eclipse v.10.0 (Varian Medical Systems). The dose calculation based on MRI data is evaluated in two different ways; a homogeneous density assigned MRI (MRI unit), where the entire body is assigned an HU equal to water and a heterogeneous...... density assigned MRI (MRI bulk) where in addition the CT segmented bone is transferred to the MRI and assigned an age dependent HU based on ICRU report 46. The CT based clinical treatment plan and structure set are registered to the corresponding MRI unit and MRI bulk. The body is outlined on both the MRI...

  19. Image to physical space registration of supine breast MRI for image guided breast surgery

    Science.gov (United States)

    Conley, Rebekah H.; Meszoely, Ingrid M.; Pheiffer, Thomas S.; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    Breast conservation therapy (BCT) is a desirable option for many women diagnosed with early stage breast cancer and involves a lumpectomy followed by radiotherapy. However, approximately 50% of eligible women will elect for mastectomy over BCT despite equal survival benefit (provided margins of excised tissue are cancer free) due to uncertainty in outcome with regards to complete excision of cancerous cells, risk of local recurrence, and cosmesis. Determining surgical margins intraoperatively is difficult and achieving negative margins is not as robust as it needs to be, resulting in high re-operation rates and often mastectomy. Magnetic resonance images (MRI) can provide detailed information about tumor margin extents, however diagnostic images are acquired in a fundamentally different patient presentation than that used in surgery. Therefore, the high quality diagnostic MRIs taken in the prone position with pendant breast are not optimal for use in surgical planning/guidance due to the drastic shape change between preoperative images and the common supine surgical position. This work proposes to investigate the value of supine MRI in an effort to localize tumors intraoperatively using image-guidance. Mock intraoperative setups (realistic patient positioning in non-sterile environment) and preoperative imaging data were collected from a patient scheduled for a lumpectomy. The mock intraoperative data included a tracked laser range scan of the patient's breast surface, tracked center points of MR visible fiducials on the patient's breast, and tracked B-mode ultrasound and strain images. The preoperative data included a supine MRI with visible fiducial markers. Fiducial markers localized in the MRI were rigidly registered to their mock intraoperative counterparts using an optically tracked stylus. The root mean square (RMS) fiducial registration error using the tracked markers was 3.4mm. Following registration, the average closest point distance between the MR

  20. Reporting and management of breast lesions detected using MRI

    International Nuclear Information System (INIS)

    Dall, B.J.G.; Vinnicombe, S.; Gilbert, F.J.

    2011-01-01

    Magnetic resonance imaging (MRI) is the most accurate technique for diagnosing and delineating the extent of both invasive and in-situ breast cancer and is increasingly being used as part of the preoperative work-up to assess the local extent of disease. It is proving invaluable in providing information that allows successful single-stage surgery. An inevitable consequence of the high sensitivity of MRI is that it will identify additional lesions that may or may not represent significant extra disease. This may complicate and delay the preoperative process. This paper outlines a strategy for managing MRI-detected lesions to optimize the benefits of breast MRI as a local staging tool while minimizing the false-positive diagnoses. It discusses the importance of good technique to reduce the number of indeterminate lesions. Methods to refine the patient pathway to minimize delays are discussed. The format of MRI reporting is discussed in detail as is the usefulness of discussion of cases at multidisciplinary meetings. Illustrative cases are used to clarify the points made.

  1. MRI and PET/CT of patients with bone metastases from breast carcinoma

    International Nuclear Information System (INIS)

    Grankvist, J.; Fisker, R.; Iyer, V.; Fründ, E.T.; Simonsen, C.; Christensen, T.; Stenbygaard, L.; Ewertz, M.; Larsson, E.-M.

    2012-01-01

    3.0 Tesla magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) was compared with combined 18F-fluorodeoxyglucose positron emission tomography and computed tomography (PET/CT) in patients with suspected bone metastases from breast cancer. A prospective clinical study was performed in 13 female breast cancer patients (mean age 61years; range 45–85 years). The spine was imaged in the sagittal plane with T1-weighted (T1), short tau inversion recovery (STIR), and T2-weighted fat-saturated (T2) sequences. The pelvis was imaged similarly in the coronal plane. Axial DWI was performed from the skull base to the mid-thigh. MRI and PET/CT were performed in all patients at a maximum interval of 10 working days and at least 14 days after chemotherapy. MRI was reviewed by two radiologists, and their consensus on potential metastases in 27 predefined locations was recorded. The predefined locations were the vertebral bodies (24), the left (1) and right (1) pelvic bones, and the sacral bone (1). The PET/CT was reviewed by a radiologists and a nuclear medicine physician. MRI detected 59 of the 60 active metastases found with our gold standard modality PET/CT. T1 had the highest sensitivity (98%) but rather low specificity (77%), but with the addition of STIR and DWI, the specificity increased to 95%. The additional metastases detected with MRI most likely represented postherapeutic residual scars without active tumour. In conclusion, 3.0 Tesla MRI with T1, STIR, and DWI is useful for the clinical evaluation of bone metastases from breast cancer and compares well to PET/CT.

  2. Breast MRI increases the number of mastectomies for ductal cancers, but decreases them for lobular cancers

    NARCIS (Netherlands)

    Lobbes, Marc B.I.; Vriens, Ingeborg J.H.; van Bommel, Annelotte C.M.; Nieuwenhuijzen, Grard A.P.; Smidt, Marjolein L.; Boersma, Liesbeth J.; van Dalen, Thijs; Smorenburg, Carolien; Struikmans, Henk; Siesling, Sabine; Voogd, Adri C.; Tjan-Heijnen, Vivianne C.G.

    2017-01-01

    Purpose In this retrospective population-based cohort study, we analyzed breast MRI use and its impact on type of surgery, surgical margin involvement, and the diagnosis of contralateral breast cancer. Methods All Dutch patients with cT1–4N0–3M0 breast cancer diagnosed in 2011–2013 and treated with

  3. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, C.W. [Department of Radiology, Jefferson Medical College, Thomas Jefferson University Hospital, 132 South 10th Street, 7th floor, Philadelphia, PA 19107-5244 (United States)

    1997-12-31

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.) With 3 figs., 70 refs.

  4. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    International Nuclear Information System (INIS)

    Piccoli, C.W.

    1997-01-01

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.)

  5. Evaluation of breast parenchymal density with QUANTRA software

    International Nuclear Information System (INIS)

    Pahwa, Shivani; Hari, Smriti; Thulkar, Sanjay; Angraal, Suveen

    2015-01-01

    To evaluate breast parenchymal density using QUANTRA software and to correlate numerical breast density values obtained from QUANTRA with ACR BI-RADS breast density categories. Two-view digital mammograms of 545 consecutive women (mean age - 47.7 years) were categorized visually by three independent radiologists into one of the four ACR BI-RADS categories (D1-D4). Numerical breast density values as obtained by QUANTRA software were then used to establish the cutoff values for each category using receiver operator characteristic (ROC) analysis. Numerical breast density values obtained by QUANTRA (range - 7-42%) were systematically lower than visual estimates. QUANTRA breast density value of less than 14.5% could accurately differentiate category D1 from the categories D2, D3, and D4 [area under curve (AUC) on ROC analysis - 94.09%, sensitivity - 85.71%, specificity - 84.21%]. QUANTRA density values of <19.5% accurately differentiated categories D1 and D2 from D3 and D4 (AUC - 94.4%, sensitivity - 87.50%, specificity - 84.60%); QUANTRA density values of <26.5% accurately differentiated categories D1, D2, and D3 from category D4 (AUC - 90.75%, sensitivity - 88.89%, specificity - 88.621%). Breast density values obtained by QUANTRA software can be used to obtain objective cutoff values for each ACR BI-RADS breast density category. Although the numerical density values obtained by QUANTRA are lower than visual estimates, they correlate well with the BI-RADS breast density categories assigned visually to the mammograms

  6. Correlation between MRI results and intraoperative findings in patients with silicone breast implants

    NARCIS (Netherlands)

    N. Lindenblatt (Nicole); K. El-Rabadi (Karem); T. Helbich (Thomas); H. Czembirek (Heinrich); M. Deutinger (Maria); H. Benditte-Klepetko (Heike)

    2014-01-01

    textabstractBackground:Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture.

  7. Real-time 3-dimensional virtual reality navigation system with open MRI for breast-conserving surgery

    International Nuclear Information System (INIS)

    Tomikawa, Morimasa; Konishi, Kozo; Ieiri, Satoshi; Hong, Jaesung; Uemura, Munenori; Hashizume, Makoto; Shiotani, Satoko; Tokunaga, Eriko; Maehara, Yoshihiko

    2011-01-01

    We report here the early experiences using a real-time three-dimensional (3D) virtual reality navigation system with open magnetic resonance imaging (MRI) for breast-conserving surgery (BCS). Two patients with a non-palpable MRI-detected breast tumor underwent BCS under the guidance of the navigation system. An initial MRI for the breast tumor using skin-affixed markers was performed immediately prior to excision. A percutaneous intramammary dye marker was applied to delineate an excision line, and the computer software '3D Slicer' generated a real-time 3D virtual reality model of the tumor and the puncture needle in the breast. Under guidance by the navigation system, marking procedures were performed without any difficulties. Fiducial registration errors were 3.00 mm for patient no.1, and 4.07 mm for patient no.2. The real-time 3D virtual reality navigation system with open MRI is feasible for safe and accurate excision of non-palpable MRI-detected breast tumors. (author)

  8. Feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory.

    Science.gov (United States)

    Wang, Haoyu; Miao, Yanwei; Zhou, Kun; Yu, Yanming; Bao, Shanglian; He, Qiang; Dai, Yongming; Xuan, Stephanie Y; Tarabishy, Bisher; Ye, Yongquan; Hu, Jiani

    2010-09-01

    To investigate the feasibility of high temporal resolution breast DCE-MRI using compressed sensing theory. Two experiments were designed to investigate the feasibility of using reference image based compressed sensing (RICS) technique in DCE-MRI of the breast. The first experiment examined the capability of RICS to faithfully reconstruct uptake curves using undersampled data sets extracted from fully sampled clinical breast DCE-MRI data. An average approach and an approach using motion estimation and motion compensation (ME/MC) were implemented to obtain reference images and to evaluate their efficacy in reducing motion related effects. The second experiment, an in vitro phantom study, tested the feasibility of RICS for improving temporal resolution without degrading the spatial resolution. For the uptake-curve reconstruction experiment, there was a high correlation between uptake curves reconstructed from fully sampled data by Fourier transform and from undersampled data by RICS, indicating high similarity between them. The mean Pearson correlation coefficients for RICS with the ME/MC approach and RICS with the average approach were 0.977 +/- 0.023 and 0.953 +/- 0.031, respectively. The comparisons of final reconstruction results between RICS with the average approach and RICS with the ME/MC approach suggested that the latter was superior to the former in reducing motion related effects. For the in vitro experiment, compared to the fully sampled method, RICS improved the temporal resolution by an acceleration factor of 10 without degrading the spatial resolution. The preliminary study demonstrates the feasibility of RICS for faithfully reconstructing uptake curves and improving temporal resolution of breast DCE-MRI without degrading the spatial resolution.

  9. Automated mammographic breast density estimation using a fully convolutional network.

    Science.gov (United States)

    Lee, Juhun; Nishikawa, Robert M

    2018-03-01

    The purpose of this study was to develop a fully automated algorithm for mammographic breast density estimation using deep learning. Our algorithm used a fully convolutional network, which is a deep learning framework for image segmentation, to segment both the breast and the dense fibroglandular areas on mammographic images. Using the segmented breast and dense areas, our algorithm computed the breast percent density (PD), which is the faction of dense area in a breast. Our dataset included full-field digital screening mammograms of 604 women, which included 1208 mediolateral oblique (MLO) and 1208 craniocaudal (CC) views. We allocated 455, 58, and 91 of 604 women and their exams into training, testing, and validation datasets, respectively. We established ground truth for the breast and the dense fibroglandular areas via manual segmentation and segmentation using a simple thresholding based on BI-RADS density assessments by radiologists, respectively. Using the mammograms and ground truth, we fine-tuned a pretrained deep learning network to train the network to segment both the breast and the fibroglandular areas. Using the validation dataset, we evaluated the performance of the proposed algorithm against radiologists' BI-RADS density assessments. Specifically, we conducted a correlation analysis between a BI-RADS density assessment of a given breast and its corresponding PD estimate by the proposed algorithm. In addition, we evaluated our algorithm in terms of its ability to classify the BI-RADS density using PD estimates, and its ability to provide consistent PD estimates for the left and the right breast and the MLO and CC views of the same women. To show the effectiveness of our algorithm, we compared the performance of our algorithm against a state of the art algorithm, laboratory for individualized breast radiodensity assessment (LIBRA). The PD estimated by our algorithm correlated well with BI-RADS density ratings by radiologists. Pearson's rho values of

  10. Hybrid {sup 18}F-FDG PET/MRI might improve locoregional staging of breast cancer patients prior to neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Goorts, Briete; Nijnatten, Thiemo J.A. van [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); Voeoe, Stefan; Wildberger, Joachim E.; Lobbes, Marc B.I. [Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); Kooreman, Loes F.S. [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Pathology, Maastricht (Netherlands); Boer, Maaike de [Maastricht University Medical Center, Department of Medical Oncology, Maastricht (Netherlands); Keymeulen, Kristien B.M.I. [Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Aarnoutse, Romy; Smidt, Marjolein L. [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Mottaghy, Felix M. [Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany)

    2017-10-15

    Our purpose in this study was to assess the added clinical value of hybrid {sup 18}F-FDG-PET/MRI compared to conventional imaging for locoregional staging in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). In this prospective study, primary invasive cT2-4 N0 or cT1-4 N+ breast cancer patients undergoing NAC were included. A PET/MRI breast protocol was performed before treatment. MR images were evaluated by a breast radiologist, blinded for PET images. PET images were evaluated by a nuclear physician. Afterwards, a combined PET/MRI report was written. PET/MRI staging was compared to conventional imaging, i.e., mammography, ultrasound and MRI. The proportion of patients with a modified treatment plan based on PET/MRI findings was analyzed. A total of 40 patients was included. PET/MRI was of added clinical value in 20.0% (8/40) of patients, changing the treatment plan in 10% and confirming the malignancy of suspicious lesions on MRI in another 10%. In seven (17.5%) patients radiotherapy fields were extended because of additional or affirmative PET/MRI findings being lymph node metastases (n = 5) and sternal bone metastases (n = 2). In one (2.5%) patient radiotherapy fields were reduced because of fewer lymph node metastases on PET/MRI compared to conventional imaging. Interestingly, all treatment changes were based on differences in number of lymph nodes suspicious for metastasis or number of distant metastasis, whereas differences in intramammary tumor extent were not observed. Prior to NAC, PET/MRI shows promising results for locoregional staging compared to conventional imaging, changing the treatment plan in 10% of patients and potentially replacing PET/CT or tissue sampling in another 10% of patients. (orig.)

  11. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2011-01-01

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  12. Supine MRI for regional breast radiotherapy: imaging axillary lymph nodes before and after sentinel-node biopsy

    Science.gov (United States)

    van Heijst, Tristan C. F.; Eschbach-Zandbergen, Debora; Hoekstra, Nienke; van Asselen, Bram; Lagendijk, Jan J. W.; Verkooijen, Helena M.; Pijnappel, Ruud M.; de Waard, Stephanie N.; Witkamp, Arjen J.; van Dalen, Thijs; Desirée van den Bongard, H. J. G.; Philippens, Marielle E. P.

    2017-08-01

    Regional radiotherapy (RT) is increasingly used in breast cancer treatment. Conventionally, computed tomography (CT) is performed for RT planning. Lymph node (LN) target levels are delineated according to anatomical boundaries. Magnetic resonance imaging (MRI) could enable individual LN delineation. The purpose was to evaluate the applicability of MRI for LN detection in supine treatment position, before and after sentinel-node biopsy (SNB). Twenty-three female breast cancer patients (cTis-3N0M0) underwent 1.5 T MRI, before and after SNB, in addition to CT. Endurance for MRI was monitored. Axillary levels were delineated. LNs were identified and delineated on MRI from before and after SNB, and on CT, and compared by Wilcoxon signed-rank tests. LN locations and LN-based volumes were related to axillary delineations and associated volumes. Although postoperative effects were visible, LN numbers on postoperative MRI (median 26 LNs) were highly reproducible compared to preoperative MRI when adding excised sentinel nodes, and higher than on CT (median 11, p  <  0.001). LN-based volumes were considerably smaller than respective axillary levels. Supine MRI of LNs is feasible and reproducible before and after SNB. This may lead to more accurate RT target definition compared to CT, with potentially lower toxicity. With the MRI techniques described here, initiation of novel MRI-guided RT strategies aiming at individual LNs could be possible.

  13. Deformable Registration for Longitudinal Breast MRI Screening.

    Science.gov (United States)

    Mehrabian, Hatef; Richmond, Lara; Lu, Yingli; Martel, Anne L

    2018-04-13

    MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T 1 -weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that

  14. Breast density in multiethnic women presenting for screening mammography.

    Science.gov (United States)

    Oppong, Bridget A; Dash, Chiranjeev; O'Neill, Suzanne; Li, Yinan; Makambi, Kepher; Pien, Edward; Makariou, Erini; Coleman, Tesha; Adams-Campbell, Lucile L

    2018-05-01

    Data on ethnic variations in breast density are limited and often not inclusive of underrepresented minorities. As breast density is associated with elevated breast cancer risk, investigating racial and ethnic difference may elucidate the observed differences in breast cancer risk among different populations. We reviewed breast density from initial screening of women from the Capital Breast Care Center and Georgetown University Hospital from 2010 to 2014. Patient demographics including race, age at screening, education, menopausal status, and body mass index were abstracted. We recorded the BI-RADS density categories: (1) "fatty," (2) "scattered fibroglandular densities," (3) "heterogeneously dense," and (4) "extremely dense." Multivariable unconditional logistic regression was used to identify predictors of breast density. Density categorization was recorded for 2146 women over the 5-year period, comprising Blacks (n = 940), Hispanics (n = 893), and Whites (n = 314). Analysis of subject characteristics by breast density showed that high category is observed in younger, Hispanic, nulliparous, premenopausal, and nonobese women (t-test or chi-square test, P-values density. Being Hispanic, premenopausal, and nonobese were predictive of high density on logistic regression. In this analysis of density distribution in a diverse sample, Hispanic women have the highest breast density, followed by Blacks and Whites. Unique in our findings is women who identify as Hispanic have the highest breast density and lower rates of obesity. Further investigation of the impact of obesity on breast density, especially in the understudied Hispanic group is needed. © 2017 Wiley Periodicals, Inc.

  15. A novel deep learning-based approach to high accuracy breast density estimation in digital mammography

    Science.gov (United States)

    Ahn, Chul Kyun; Heo, Changyong; Jin, Heongmin; Kim, Jong Hyo

    2017-03-01

    Mammographic breast density is a well-established marker for breast cancer risk. However, accurate measurement of dense tissue is a difficult task due to faint contrast and significant variations in background fatty tissue. This study presents a novel method for automated mammographic density estimation based on Convolutional Neural Network (CNN). A total of 397 full-field digital mammograms were selected from Seoul National University Hospital. Among them, 297 mammograms were randomly selected as a training set and the rest 100 mammograms were used for a test set. We designed a CNN architecture suitable to learn the imaging characteristic from a multitudes of sub-images and classify them into dense and fatty tissues. To train the CNN, not only local statistics but also global statistics extracted from an image set were used. The image set was composed of original mammogram and eigen-image which was able to capture the X-ray characteristics in despite of the fact that CNN is well known to effectively extract features on original image. The 100 test images which was not used in training the CNN was used to validate the performance. The correlation coefficient between the breast estimates by the CNN and those by the expert's manual measurement was 0.96. Our study demonstrated the feasibility of incorporating the deep learning technology into radiology practice, especially for breast density estimation. The proposed method has a potential to be used as an automated and quantitative assessment tool for mammographic breast density in routine practice.

  16. MRI fused with prone FDG PET/CT improves the primary tumour staging of patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Velloso, Maria J.; Ribelles, Maria J.; Rodriguez, Macarena; Sancho, Lidia; Prieto, Elena [Clinica Universidad de Navarra, Department of Nuclear Medicine, Pamplona (Spain); Fernandez-Montero, Alejandro [Clinica Universidad de Navarra, Department of Occupational Medicine, Pamplona (Spain); Santisteban, Marta [Clinica Universidad de Navarra, Department of Oncology, Pamplona (Spain); Rodriguez-Spiteri, Natalia; Martinez-Regueira, Fernando [Clinica Universidad de Navarra, Department of Surgery, Pamplona (Spain); Idoate, Miguel A. [Clinica Universidad de Navarra, Department of Pathology, Pamplona (Spain); Elizalde, Arlette; Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona (Spain)

    2017-08-15

    Our aim was to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in primary tumour staging of patients with breast cancer. This retrospective study evaluated 45 women with 49 pathologically proven breast carcinomas. MRI and prone PET-CT scans with time-of-flight and point-spread-function reconstruction were performed with the same dedicated breast coil. The studies were assessed by a radiologist and a nuclear medicine physician, and evaluation of fused images was made by consensus. The final diagnosis was based on pathology (90 lesions) or follow-up ≥ 24 months (17 lesions). The study assessed 72 malignant and 35 benign lesions with a median size of 1.8 cm (range 0.3-8.4 cm): 31 focal, nine multifocal and nine multicentric cases. In lesion-by-lesion analysis, sensitivity, specificity, positive and negative predictive values were 97%, 80%, 91% and 93% for MRI, 96%, 71%, 87%, and 89% for prone PET, and 97%. 94%, 97% and 94% for MRI fused with PET. Areas under the curve (AUC) were 0.953, 0.850, and 0.983, respectively (p < 0.01). MRI fused with FDG-PET is more accurate than FDG-PET in primary tumour staging of breast cancer patients and increases the specificity of MRI. (orig.)

  17. Combining quantitative and qualitative breast density measures to assess breast cancer risk.

    Science.gov (United States)

    Kerlikowske, Karla; Ma, Lin; Scott, Christopher G; Mahmoudzadeh, Amir P; Jensen, Matthew R; Sprague, Brian L; Henderson, Louise M; Pankratz, V Shane; Cummings, Steven R; Miglioretti, Diana L; Vachon, Celine M; Shepherd, John A

    2017-08-22

    Accurately identifying women with dense breasts (Breast Imaging Reporting and Data System [BI-RADS] heterogeneously or extremely dense) who are at high breast cancer risk will facilitate discussions of supplemental imaging and primary prevention. We examined the independent contribution of dense breast volume and BI-RADS breast density to predict invasive breast cancer and whether dense breast volume combined with Breast Cancer Surveillance Consortium (BCSC) risk model factors (age, race/ethnicity, family history of breast cancer, history of breast biopsy, and BI-RADS breast density) improves identifying women with dense breasts at high breast cancer risk. We conducted a case-control study of 1720 women with invasive cancer and 3686 control subjects. We calculated ORs and 95% CIs for the effect of BI-RADS breast density and Volpara™ automated dense breast volume on invasive cancer risk, adjusting for other BCSC risk model factors plus body mass index (BMI), and we compared C-statistics between models. We calculated BCSC 5-year breast cancer risk, incorporating the adjusted ORs associated with dense breast volume. Compared with women with BI-RADS scattered fibroglandular densities and second-quartile dense breast volume, women with BI-RADS extremely dense breasts and third- or fourth-quartile dense breast volume (75% of women with extremely dense breasts) had high breast cancer risk (OR 2.87, 95% CI 1.84-4.47, and OR 2.56, 95% CI 1.87-3.52, respectively), whereas women with extremely dense breasts and first- or second-quartile dense breast volume were not at significantly increased breast cancer risk (OR 1.53, 95% CI 0.75-3.09, and OR 1.50, 95% CI 0.82-2.73, respectively). Adding continuous dense breast volume to a model with BCSC risk model factors and BMI increased discriminatory accuracy compared with a model with only BCSC risk model factors (C-statistic 0.639, 95% CI 0.623-0.654, vs. C-statistic 0.614, 95% CI 0.598-0.630, respectively; P breasts and fourth

  18. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.

    Science.gov (United States)

    Castillo-García, Maria; Chevalier, Margarita; Garayoa, Julia; Rodriguez-Ruiz, Alejandro; García-Pinto, Diego; Valverde, Julio

    2017-07-01

    The study aimed to compare the breast density estimates from two algorithms on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and to analyze the clinical implications. We selected 561 FFDM and DBT examinations from patients without breast pathologies. Two versions of a commercial software (Quantra 2D and Quantra 3D) calculated the volumetric breast density automatically in FFDM and DBT, respectively. Other parameters such as area breast density and total breast volume were evaluated. We compared the results from both algorithms using the Mann-Whitney U non-parametric test and the Spearman's rank coefficient for data correlation analysis. Mean glandular dose (MGD) was calculated following the methodology proposed by Dance et al. Measurements with both algorithms are well correlated (r ≥ 0.77). However, there are statistically significant differences between the medians (P density median values from FFDM are, respectively, 8% and 77% higher than DBT estimations. Both algorithms classify 35% and 55% of breasts into BIRADS (Breast Imaging-Reporting and Data System) b and c categories, respectively. There are no significant differences between the MGD calculated using the breast density from each algorithm. DBT delivers higher MGD than FFDM, with a lower difference (5%) for breasts in the BIRADS d category. MGD is, on average, 6% higher than values obtained with the breast glandularity proposed by Dance et al. Breast density measurements from both algorithms lead to equivalent BIRADS classification and MGD values, hence showing no difference in clinical outcomes. The median MGD values of FFDM and DBT examinations are similar for dense breasts (BIRADS d category). Published by Elsevier Inc.

  19. Breast MRI: EUSOBI recommendations for women's information

    NARCIS (Netherlands)

    Mann, R.M.; Balleyguier, C.; Baltzer, P.A.; Bick, U.; Colin, C.; Cornford, E.; Evans, A.; Fallenberg, E.; Forrai, G.; Fuchsjager, M.H.; Gilbert, F.J.; Helbich, T.H.; Heywang-Kobrunner, S.H.; Camps-Herrero, J.; Kuhl, C.K.; Martincich, L.; Pediconi, F.; Panizza, P.; Pina, L.J.; Pijnappel, R.M.; Pinker-Domenig, K.; Skaane, P.; Sardanelli, F.; Imaging, w.l.r.b.E.D.-T.E.B.C.C. European Societ

    2015-01-01

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS(R)

  20. Breast MRI : EUSOBI recommendations for women's information

    NARCIS (Netherlands)

    Mann, Ritse M.; Balleyguier, Corinne; Baltzer, Pascal A.; Bick, Ulrich; Colin, Catherine; Cornford, Eleanor; Evans, Andrew; Fallenberg, Eva; Forrai, Gabor; Fuchsjaeger, Michael H.; Gilbert, Fiona J.; Helbich, Thomas H.; Heywang-Koebrunner, Sylvia H.; Camps-Herrero, Julia; Kuhl, Christiane K.; Martincich, Laura; Pediconi, Federica; Panizza, Pietro; Pina, Luis J.; Pijnappel, Ruud M.; Pinker-Domenig, Katja; Skaane, Per; Sardanelli, Francesco

    2015-01-01

    This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADSA (R)

  1. Role of pharmacokinetic parameters derived with high temporal resolution DCE MRI using simultaneous PET/MRI system in breast cancer: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Jena, Amarnath, E-mail: drjena2002@gmail.com [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Taneja, Sangeeta; Singh, Aru; Negi, Pradeep; Mehta, Shashi Bhushan [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Sarin, Ramesh [Department of Surgical Oncology, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India)

    2017-01-15

    Highlights: • Simultaneous PET/MRI (with 3T MRI in the core) for quantitative pharmacokinetics. • Diagnostic accuracy of pharmacokinetic parameters like K{sup trans}, K{sub ep} and v{sub e} acquired through this system. • Incorporating high temporal resolution sequence with short acquisition time of 60 s within the routine DCE MRI in a simultaneous PET/MRI system. - Abstract: Purpose: To evaluate the reliability of pharmacokinetic parameters like K{sup trans}, Kep and v{sub e} derived through DCE MRI breast protocol using 3 T Simultaneous PET/MRI (3 Tesla Positron Emission Tomography/Magnetic Resonance Imaging) system in distinguishing benign and malignant lesions. Materials and methods: High temporal resolution DCE (Dynamic Contrast Enhancement) MRI performed as routine breast MRI for diagnosis or as a part of PET/MRI for cancer staging using a 3 T simultaneous PET/MRI system in 98 women having 109 breast lesions were analyzed for calculation of pharmacokinetic parameters (K{sup trans}, v{sub e}, and Kep) at 60 s time point using an in-house developed computation scheme. Results: Receiver operating characteristic (ROC) curve analysis revealed a cut off value for K{sup trans}, Kep, v{sub e} as 0.50, 2.59, 0.15 respectively which reliably distinguished benign and malignant breast lesions. Data analysis revealed an overall accuracy of 94.50%, 79.82% and 87.16% for K{sup trans}, Kep, v{sub e} respectively. Introduction of native T1 normalization with an externally placed phantom showed a higher accuracy (94.50%) than without native T1 normalization (93.50%) with an increase in specificity of 87% vs 84%. Conclusion: Overall the results indicate that reliable measurement of pharmacokinetic parameters with reduced acquisition time is feasible in a 3TMRI embedded PET/MRI system with reasonable accuracy and application may be extended to exploit the potential of simultaneous PET/MRI in further work on breast cancer.

  2. Time to enhancement derived from ultrafast breast MRI as a novel parameter to discriminate benign from malignant breast lesions

    International Nuclear Information System (INIS)

    Mus, Roel D.; Borelli, Cristina; Bult, Peter; Weiland, Elisabeth; Karssemeijer, Nico; Barentsz, Jelle O.; Gubern-Mérida, Albert; Platel, Bram; Mann, Ritse M.

    2017-01-01

    Highlights: • New view-sharing sequences (e.g. TWIST) enable ultrafast dynamic breast MRI. • TWIST sequences accurately characterize the inflow of contrast in breast lesions. • TTE evaluation allows breast lesion classification with very high accuracy. • The use of TTE significantly increases the specificity of breast MRI. • TWIST imaging may increase the potential of breast MRI as screening tool. - Abstract: Objectives: To investigate time to enhancement (TTE) as novel dynamic parameter for lesion classification in breast magnetic resonance imaging (MRI). Methods: In this retrospective study, 157 women with 195 enhancing abnormalities (99 malignant and 96 benign) were included. All patients underwent a bi-temporal MRI protocol that included ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (1.0 × 0.9 × 2.5 mm, temporal resolution 4.32 s), during the inflow of contrast agent. TTE derived from TWIST series and relative enhancement versus time curve type derived from volumetric interpolated breath-hold examination (VIBE) series were assessed and combined with basic morphological information to differentiate benign from malignant lesions. Receiver operating characteristic analysis and kappa statistics were applied. Results: TTE had a significantly better discriminative ability than curve type (p < 0.001 and p = 0.026 for reader 1 and 2, respectively). Including morphology, sensitivity of TWIST and VIBE assessment was equivalent (p = 0.549 and p = 0.344, respectively). Specificity and diagnostic accuracy were significantly higher for TWIST than for VIBE assessment (p < 0.001). Inter-reader agreement in differentiating malignant from benign lesions was almost perfect for TWIST evaluation (κ = 0.86) and substantial for conventional assessment (κ = 0.75). Conclusions: TTE derived from ultrafast TWIST acquisitions is a valuable parameter that allows robust differentiation between malignant and benign breast lesions with high

  3. Time to enhancement derived from ultrafast breast MRI as a novel parameter to discriminate benign from malignant breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Mus, Roel D., E-mail: aroel.mus@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Borelli, Cristina, E-mail: cristinaborelli@hotmail.it [Department of Radiology, Scientific Institute “Casa Sollievo della Sofferenza” Hospital, Viale Cappuccini 1, 71013, San Giovanni Rotondo, Foggia (Italy); Department of Radiology, Radboud University Medical Center (internal address 766), Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Bult, Peter, E-mail: peter.bult@radboudumc.nl [Department of Pathology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Weiland, Elisabeth, E-mail: elisabeth.weiland@siemens.com [Siemens Healthcare, Erlangen (Germany); Karssemeijer, Nico, E-mail: nico.karssemeijer@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Barentsz, Jelle O., E-mail: jelle.barentsz@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Gubern-Mérida, Albert, E-mail: albert.gubernmerida@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Platel, Bram, E-mail: bram.platel@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands); Mann, Ritse M., E-mail: ritse.mann@radboudumc.nl [Department of Radiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA Nijmegen (Netherlands)

    2017-04-15

    Highlights: • New view-sharing sequences (e.g. TWIST) enable ultrafast dynamic breast MRI. • TWIST sequences accurately characterize the inflow of contrast in breast lesions. • TTE evaluation allows breast lesion classification with very high accuracy. • The use of TTE significantly increases the specificity of breast MRI. • TWIST imaging may increase the potential of breast MRI as screening tool. - Abstract: Objectives: To investigate time to enhancement (TTE) as novel dynamic parameter for lesion classification in breast magnetic resonance imaging (MRI). Methods: In this retrospective study, 157 women with 195 enhancing abnormalities (99 malignant and 96 benign) were included. All patients underwent a bi-temporal MRI protocol that included ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (1.0 × 0.9 × 2.5 mm, temporal resolution 4.32 s), during the inflow of contrast agent. TTE derived from TWIST series and relative enhancement versus time curve type derived from volumetric interpolated breath-hold examination (VIBE) series were assessed and combined with basic morphological information to differentiate benign from malignant lesions. Receiver operating characteristic analysis and kappa statistics were applied. Results: TTE had a significantly better discriminative ability than curve type (p < 0.001 and p = 0.026 for reader 1 and 2, respectively). Including morphology, sensitivity of TWIST and VIBE assessment was equivalent (p = 0.549 and p = 0.344, respectively). Specificity and diagnostic accuracy were significantly higher for TWIST than for VIBE assessment (p < 0.001). Inter-reader agreement in differentiating malignant from benign lesions was almost perfect for TWIST evaluation (κ = 0.86) and substantial for conventional assessment (κ = 0.75). Conclusions: TTE derived from ultrafast TWIST acquisitions is a valuable parameter that allows robust differentiation between malignant and benign breast lesions with high

  4. Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast.

    Science.gov (United States)

    Iima, Mami; Kataoka, Masako; Kanao, Shotaro; Kawai, Makiko; Onishi, Natsuko; Koyasu, Sho; Murata, Katsutoshi; Ohashi, Akane; Sakaguchi, Rena; Togashi, Kaori

    2018-01-01

    We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0-2500 s/mm2 with one number of excitations [NEX]) and five b-values (0-2500 s/mm2, 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC0, K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions.

  5. The quality of tumor size assessment by contrast-enhanced spectral mammography and the benefit of additional breast MRI.

    Science.gov (United States)

    Lobbes, Marc B I; Lalji, Ulrich C; Nelemans, Patty J; Houben, Ivo; Smidt, Marjolein L; Heuts, Esther; de Vries, Bart; Wildberger, Joachim E; Beets-Tan, Regina G

    2015-01-01

    Background - Contrast-enhanced spectral mammography (CESM) is a promising new breast imaging modality that is superior to conventional mammography for breast cancer detection. We aimed to evaluate correlation and agreement of tumor size measurements using CESM. As additional analysis, we evaluated whether measurements using an additional breast MRI exam would yield more accurate results. Methods - Between January 1(st) 2013 and April 1(st) 2014, 87 consecutive breast cancer cases that underwent CESM were collected and data on maximum tumor size measurements were gathered. In 57 cases, tumor size measurements were also available for breast MRI. Histopathological results of the surgical specimen served as gold standard in all cases. Results - The Pearson's correlation coefficients (PCC) of CESM versus histopathology and breast MRI versus histopathology were all >0.9, p1 cm between the two imaging modalities and histopathological results, we did not observe any advantage of performing an additional breast MRI after CESM in any of the cases. Conclusion - Quality of tumor size measurement using CESM is good and matches the quality of these measurement assessed by breast MRI. Additional measurements using breast MRI did not improve the quality of tumor size measurements.

  6. Significance of Additional Non-Mass Enhancement in Patients with Breast Cancer on Preoperative 3T Dynamic Contrast Enhanced MRI of the Breast

    International Nuclear Information System (INIS)

    Cho, Yun Hee; Cho, Kyu Ran; Park, Eun Kyung; Seo, Bo Kyoung; Woo, Ok Hee; Cho, Sung Bum; Bae, Jeoung Won

    2016-01-01

    In preoperative assessment of breast cancer, MRI has been shown to identify more additional breast lesions than are detectable using conventional imaging techniques. The characterization of additional lesions is more important than detection for optimal surgical treatment. Additional breast lesions can be included in focus, mass, and non-mass enhancement (NME) on MRI. According to the fifth edition of the breast imaging reporting and data system (BI-RADS®), which includes several changes in the NME descriptors, few studies to date have evaluated NME in preoperative assessment of breast cancer. We investigated the diagnostic accuracy of BI-RADS descriptors in predicting malignancy for additional NME lesions detected on preoperative 3T dynamic contrast enhanced MRI (DCE-MRI) in patients with newly diagnosed breast cancer. Between January 2008 and December 2012, 88 patients were enrolled in our study, all with NME lesions other than the index cancer on preoperative 3T DCE-MRI and all with accompanying histopathologic examination. The MRI findings were analyzed according to the BI-RADS MRI lexicon. We evaluated the size, distribution, internal enhancement pattern, and location of NME lesions relative to the index cancer (i.e., same quadrant, different quadrant, or contralateral breast). On histopathologic analysis of the 88 NME lesions, 73 (83%) were malignant and 15 (17%) were benign. Lesion size did not differ significantly between malignant and benign lesions (P = 0.410). Malignancy was more frequent in linear (P = 0.005) and segmental (P = 0.011) distributions, and benignancy was more frequent in focal (P = 0.004) and regional (P < 0.001) NME lesions. The highest positive predictive value (PPV) for malignancy occurred in segmental (96.8%), linear (95.1%), clustered ring (100%), and clumped (92.0%) enhancement. Asymmetry demonstrated a high positive predictive value of 85.9%. The frequency of malignancy was higher for NME lesions located in the same quadrant with

  7. Role of MRI in differentiating benign from malignant breast lesions ...

    African Journals Online (AJOL)

    Mohamed Ahmed Youssef

    2017-02-15

    Feb 15, 2017 ... detecting breast lesions than either T1- or T2-weighted imaging, but it is better to be performed in con- junction with contrast ... of MRI in several aspects of breast cancer diagnosis and management.2 ..... Hayes DF.: Normal ...

  8. Preoperative prediction of sentinel lymph node metastasis in breast cancer based on radiomics of T2-weighted fat-suppression and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yuhao; Mo, Xiaokai [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Shantou University Medical College, Graduate College, Shantou, Guangdong (China); Feng, Qianjin; Yang, Wei; Lu, Zixiao; Deng, Chunyan [Southern Medical University, The Guangdong Provincial Key Laboratory of Medical Image Processing, School of Biomedical Engineering, Guangzhou, Guangdong (China); Zhang, Lu; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Pei, Shufang; Huang, Wenhui; Liang, Changhong; Zhang, Bin; Zhang, Shuixing [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China)

    2018-02-15

    To predict sentinel lymph node (SLN) metastasis in breast cancer patients using radiomics based on T{sub 2}-weighted fat suppression (T{sub 2}-FS) and diffusion-weighted MRI (DWI). We enrolled 146 patients with histologically proven breast cancer. All underwent pretreatment T{sub 2}-FS and DWI MRI scan. In all, 10,962 texture and four non-texture features were extracted for each patient. The 0.623 + bootstrap method and the area under the curve (AUC) were used to select the features. We constructed ten logistic regression models (orders of 1-10) based on different combination of image features using stepwise forward method. For T{sub 2}-FS, model 10 with ten features yielded the highest AUC of 0.847 in the training set and 0.770 in the validation set. For DWI, model 8 with eight features reached the highest AUC of 0.847 in the training set and 0.787 in the validation set. For joint T{sub 2}-FS and DWI, model 10 with ten features yielded an AUC of 0.863 in the training set and 0.805 in the validation set. Full utilisation of breast cancer-specific textural features extracted from anatomical and functional MRI images improves the performance of radiomics in predicting SLN metastasis, providing a non-invasive approach in clinical practice. (orig.)

  9. A new look at breast density and breast cancer risk

    NARCIS (Netherlands)

    Haars, G.

    2008-01-01

    Breast density, as visible on mammograms, comprises connective and epithelial tissue and can be seen to represent the glandular target tissue for breast cancer, whereas the non-dense tissue mainly comprises fat. High percentages of density are established to be one of the strongest risk factors of

  10. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, Takayoshi [Shizuoka Cancer Center Hospital, Breast Imaging and Breast Intervention Section, Shizuoka (Japan); Kasami, Masako [Shizuoka Cancer Center Hospital, Department of Pathology, Naga-izumi, Shizuoka (Japan); Watanabe, Junichiro [Shizuoka Cancer Center Hospital, Division of Medical Oncology, Naga-izumi, Shizuoka (Japan)

    2011-11-15

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  11. Quantitative assessment of breast density from digitized mammograms into Tabar's patterns

    International Nuclear Information System (INIS)

    Jamal, N; Ng, K-H; Looi, L-M; McLean, D; Zulfiqar, A; Tan, S-P; Liew, W-F; Shantini, A; Ranganathan, S

    2006-01-01

    We describe a semi-automated technique for the quantitative assessment of breast density from digitized mammograms in comparison with patterns suggested by Tabar. It was developed using the MATLAB-based graphical user interface applications. It is based on an interactive thresholding method, after a short automated method that shows the fibroglandular tissue area, breast area and breast density each time new thresholds are placed on the image. The breast density is taken as a percentage of the fibroglandular tissue to the breast tissue areas. It was tested in four different ways, namely by examining: (i) correlation of the quantitative assessment results with subjective classification, (ii) classification performance using the quantitative assessment technique, (iii) interobserver agreement and (iv) intraobserver agreement. The results of the quantitative assessment correlated well (r 2 = 0.92) with the subjective Tabar patterns classified by the radiologist (correctly classified 83% of digitized mammograms). The average kappa coefficient for the agreement between the readers was 0.63. This indicated moderate agreement between the three observers in classifying breast density using the quantitative assessment technique. The kappa coefficient of 0.75 for intraobserver agreement reflected good agreement between two sets of readings. The technique may be useful as a supplement to the radiologist's assessment in classifying mammograms into Tabar's pattern associated with breast cancer risk

  12. MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), General Hospital Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2014-06-15

    To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI). This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis. Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 x 10{sup -3} mm{sup 2}/s in benign lesions and 1.06 ± 0.27 x 10{sup -3} mm{sup 2}/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 x 10{sup -3} mm{sup 2}/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis. Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols. (orig.)

  13. Postmortem validation of breast density using dual-energy mammography

    Energy Technology Data Exchange (ETDEWEB)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A. [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

  14. Postmortem validation of breast density using dual-energy mammography

    International Nuclear Information System (INIS)

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer

  15. Model–Free Visualization of Suspicious Lesions in Breast MRI Based on Supervised and Unsupervised Learning

    NARCIS (Netherlands)

    Twellmann, T.; Meyer-Bäse, A.; Lange, O.; Foo, S.; Nattkemper, T.W.

    2008-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important tool in breast cancer diagnosis, but evaluation of multitemporal 3D image data holds new challenges for human observers. To aid the image analysis process, we apply supervised and unsupervised pattern recognition

  16. Implementation of several mathematical algorithms to breast tissue density classification

    International Nuclear Information System (INIS)

    Quintana, C.; Redondo, M.; Tirao, G.

    2014-01-01

    The accuracy of mammographic abnormality detection methods is strongly dependent on breast tissue characteristics, where a dense breast tissue can hide lesions causing cancer to be detected at later stages. In addition, breast tissue density is widely accepted to be an important risk indicator for the development of breast cancer. This paper presents the implementation and the performance of different mathematical algorithms designed to standardize the categorization of mammographic images, according to the American College of Radiology classifications. These mathematical techniques are based on intrinsic properties calculations and on comparison with an ideal homogeneous image (joint entropy, mutual information, normalized cross correlation and index Q) as categorization parameters. The algorithms evaluation was performed on 100 cases of the mammographic data sets provided by the Ministerio de Salud de la Provincia de Córdoba, Argentina—Programa de Prevención del Cáncer de Mama (Department of Public Health, Córdoba, Argentina, Breast Cancer Prevention Program). The obtained breast classifications were compared with the expert medical diagnostics, showing a good performance. The implemented algorithms revealed a high potentiality to classify breasts into tissue density categories. - Highlights: • Breast density classification can be obtained by suitable mathematical algorithms. • Mathematical processing help radiologists to obtain the BI-RADS classification. • The entropy and joint entropy show high performance for density classification

  17. Breast density pattern characterization by histogram features and texture descriptors

    Directory of Open Access Journals (Sweden)

    Pedro Cunha Carneiro

    2017-04-01

    Full Text Available Abstract Introduction Breast cancer is the first leading cause of death for women in Brazil as well as in most countries in the world. Due to the relation between the breast density and the risk of breast cancer, in medical practice, the breast density classification is merely visual and dependent on professional experience, making this task very subjective. The purpose of this paper is to investigate image features based on histograms and Haralick texture descriptors so as to separate mammographic images into categories of breast density using an Artificial Neural Network. Methods We used 307 mammographic images from the INbreast digital database, extracting histogram features and texture descriptors of all mammograms and selecting them with the K-means technique. Then, these groups of selected features were used as inputs of an Artificial Neural Network to classify the images automatically into the four categories reported by radiologists. Results An average accuracy of 92.9% was obtained in a few tests using only some of the Haralick texture descriptors. Also, the accuracy rate increased to 98.95% when texture descriptors were mixed with some features based on a histogram. Conclusion Texture descriptors have proven to be better than gray levels features at differentiating the breast densities in mammographic images. From this paper, it was possible to automate the feature selection and the classification with acceptable error rates since the extraction of the features is suitable to the characteristics of the images involving the problem.

  18. Background enhancement in breast MR: Correlation with breast density in mammography and background echotexture in ultrasound

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Lee, Byung Hee; Choi, Hye Young; Kim, Rock Bum; Noh, Woo-Chul

    2011-01-01

    Objective: This study aimed to determine whether background enhancement on MR was related to mammographic breast density or ultrasonographic background echotexture in premenopausal and postmenopausal women. Materials and methods: We studied 142 patients (79 premenopausal, 63 postmenopausal) who underwent mammography, ultrasonography, and breast MR. We reviewed the mammography for overall breast density of the contralateral normal breast according to the four-point scale of the BI-RADS classification. Ultrasound findings were classified as homogeneous or heterogeneous background echotexture according to the BI-RADS lexicon. We rated background enhancement on a contralateral breast MR into four categories based on subtraction images: absent, mild, moderate, and marked. All imaging findings were interpreted independently by two readers without knowledge of menstrual status, imaging findings of other modalities. Results: There were significant differences between the premenopausal and postmenopausal group in distribution of mammographic breast density, ultrasonographic background echotexture, and degree of background enhancement. Regarding the relationship between mammographic density and background enhancement, there was no significant correlation. There was significant relationship between ultrasonographic background echotexture and background enhancement in both premenopausal and postmenopausal groups. Conclusion: There is a significant correlation between ultrasonographic background echotexture and background enhancement in MR regardless of menopausal status. Interpreting breast MR, or scheduling for breast MR of women showing heterogeneous background echotexture needs more caution.

  19. High field MRI of axillary lymph nodes and breast cancer

    NARCIS (Netherlands)

    Korteweg, M.A.

    2011-01-01

    In this thesis nodal characteristics have been assessed with high field Magnetic Resonance Imaging (MRI) using a clinical scanner in order to discriminate non-metastatic from metastatic nodes of breast cancer patients. The final goal is to non-invasively determine nodal and tumor stage of breast

  20. MRI monitoring of tumor response following angiogenesis inhibition in an experimental human breast cancer model

    International Nuclear Information System (INIS)

    Turetschek, Karl; Preda, Anda; Shames, David M.; Novikov, Viktor; Roberts, Timothy P.L.; Fu, Yanjun; Brasch, Robert C.; Floyd, Eugenia; Carter, Wayne O.; Wood, Jeanette M.

    2003-01-01

    The aim of this study was to evaluate the potential of dynamic magnetic resonance imaging (MRI) enhanced by macromolecular contrast agents to monitor noninvasively the therapeutic effect of an anti-angiogenesis VEGF receptor kinase inhibitor in an experimental cancer model. MDA-MB-435, a poorly differentiated human breast cancer cell line, was implanted into the mammary fat pad in 20 female homozygous athymic rats. Animals were assigned randomly to a control (n=10) or drug treatment group (n=10). Baseline dynamic MRI was performed on sequential days using albumin-(GdDTPA) 30 (6.0 nm diameter) and ultrasmall superparamagnetic iron oxide (USPIO) particles (30 nm diameter). Subjects were treated either with PTK787/ZK 222584, a VEGF receptor tyrosine kinase inhibitor, or saline given orally twice daily for 1 week followed by repeat MRI examinations serially using each contrast agent. Employing a unidirectional kinetic model comprising the plasma and interstitial water compartments, tumor microvessel characteristics including fractional plasma volume and transendothelial permeability (K PS ) were estimated for each contrast medium. Tumor growth and the microvascular density, a histologic surrogate of angiogenesis, were also measured. Control tumors significantly increased (P PS ) based on MRI assays using both macromolecular contrast media. In contrast, tumor growth was significantly reduced (P PS values declined slightly. Estimated values for the fractional plasma volume did not differ significantly between treatment groups or contrast agents. Microvascular density counts correlated fairly with the tumor growth rate (r=0.64) and were statistically significant higher (P PS ), using either of two macromolecular contrast media, were able to detect effects of treatment with a VEGF receptor tyrosine kinase inhibitor on tumor vascular permeability. In a clinical setting such quantitative MRI measurements could be used to monitor tumor anti-angiogenesis therapy. (orig.)

  1. Overview of the role of pre-operative breast MRI in the absence of evidence on patient outcomes.

    Science.gov (United States)

    Sardanelli, Francesco

    2010-02-01

    The role of pre-operative breast MRI is outlined on the basis of the existing evidence in favor of a superior capability in comparison with mammography and sonography to detect ipsilateral and contralateral malignant lesions and to evaluate the disease extent, including the extensive intraductal component associated with invasive cancers. Patients with a potential higher anticipated benefit from pre-operative MRI can be identified as those: with mammographically dense breasts; with a unilateral multifocal/multicentric cancer or a synchronous bilateral cancer already diagnosed at mammography and sonography; with a lobular invasive cancer; at high-risk for breast cancer; with a cancer which shows a discrepancy in size of >1 cm between mammography and sonography; or under consideration for partial breast irradiation. More limited evidence exists in favor of MRI for evaluating candidates for total skin sparing mastectomy or for patients with Paget's disease. Irrespective of whether the clinical team routinely uses preoperative MRI or not: women newly diagnosed with breast cancer should always be informed of the potential risks and benefits of pre-operative MRI; results of pre-operative MRI should be interpreted taking into account clinical breast examination, mammography, sonography and verified by percutaneous biopsy; MRI-only detected lesions require MR-guidance for needle biopsy and pre-surgical localization, and these should be available or potentially accessible if pre-operative MRI is to be implemented; total therapy delay due to pre-operative MRI (including MRI-induced work-up) should not exceed one month; changes in therapy planning resulting from pre-operative MRI should be decided by a multidisciplinary team. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  2. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  3. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  4. Relationship between DCE-MRI morphological and functional features and histopathological characteristics of breast cancer

    International Nuclear Information System (INIS)

    Montemurro, Filippo; Redana, Stefania; Aglietta, Massimo; Martincich, Laura; Bertotto, Ilaria; Cellini, Lisa; Sarotto, Ivana; Ponzone, Riccardo; Sismondi, Piero; Regge, Daniele

    2007-01-01

    We studied whether dynamic contrast-enhanced MRI (DCE-MRI) could identify histopathological characteristics of breast cancer. Seventy-five patients with breast cancer underwent DCE-MRI followed by core biopsy. DCE-MRI findings were evaluated following the scoring system published by Fischer in 1999. In this scoring system, five DCE-MRI features, three morphological (shape, margins, enhancement kinetic) and two functional (initial peak of signal intensity (SI) increase and behavior of signal intensity curve), are defined by 14 parameters. Each parameter is assigned points ranging from 0 to 1 or 0 to 2, with higher points for those that are more likely to be associated with malignancy. The sum of all the points defines the degree of suspicion of malignancy, with a score 0 representing the lowest and 8 the highest degree of suspicion. Associations between DCE-MRI features and tumor histopathological characteristics assessed on core biopsies (histological type, grading, estrogen and progesterone receptor status, Ki67 and HER2 status) were studied by contingency tables and logistic regression analysis. We found a significant inverse association between the Fischer's score and HER2-overexpression (odds ratio-OR 0.608, p = 0.02). Based on our results, we suggest that lesions with intermediate-low suspicious DCE-MRI parameters may represent a subset of tumor with poor histopathological characteristics. (orig.)

  5. Using Clinical Factors and Mammographic Breast Density to Estimate Breast Cancer Risk: Development and Validation of a New Predictive Model

    Science.gov (United States)

    Tice, Jeffrey A.; Cummings, Steven R.; Smith-Bindman, Rebecca; Ichikawa, Laura; Barlow, William E.; Kerlikowske, Karla

    2009-01-01

    Background Current models for assessing breast cancer risk are complex and do not include breast density, a strong risk factor for breast cancer that is routinely reported with mammography. Objective To develop and validate an easy-to-use breast cancer risk prediction model that includes breast density. Design Empirical model based on Surveillance, Epidemiology, and End Results incidence, and relative hazards from a prospective cohort. Setting Screening mammography sites participating in the Breast Cancer Surveillance Consortium. Patients 1 095 484 women undergoing mammography who had no previous diagnosis of breast cancer. Measurements Self-reported age, race or ethnicity, family history of breast cancer, and history of breast biopsy. Community radiologists rated breast density by using 4 Breast Imaging Reporting and Data System categories. Results During 5.3 years of follow-up, invasive breast cancer was diagnosed in 14 766 women. The breast density model was well calibrated overall (expected–observed ratio, 1.03 [95% CI, 0.99 to 1.06]) and in racial and ethnic subgroups. It had modest discriminatory accuracy (concordance index, 0.66 [CI, 0.65 to 0.67]). Women with low-density mammograms had 5-year risks less than 1.67% unless they had a family history of breast cancer and were older than age 65 years. Limitation The model has only modest ability to discriminate between women who will develop breast cancer and those who will not. Conclusion A breast cancer prediction model that incorporates routinely reported measures of breast density can estimate 5-year risk for invasive breast cancer. Its accuracy needs to be further evaluated in independent populations before it can be recommended for clinical use. PMID:18316752

  6. Routine use of standard breast MRI compared to axillary ultrasound for differentiating between no, limited and advanced axillary nodal disease in newly diagnosed breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, T.J.A. van, E-mail: Thiemovn@gmail.com [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Ploumen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Schipper, RJ. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Catharina Hospital, Eindhoven (Netherlands); Goorts, B. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Andriessen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Vanwetswinkel, S.; Schavemaker, M. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Nelemans, P. [Department of Epidemiology, Maastricht University Medical Center+, Maastricht (Netherlands); Vries, B. de [Department of Pathology, Zuyderland Hospital, Heerlen (Netherlands); and others

    2016-12-15

    Objectives: To compare standard breast MRI to dedicated axillary ultrasound (with or without tissue sampling) for differentiating between no, limited and advanced axillary nodal disease in breast cancer patients. Methods: All patients who underwent breast MRI and dedicated axillary ultrasound between 2009 and 2014 were eligible. Exclusion criteria were recurrent disease, neoadjuvant systemic therapy and not receiving completion axillary lymph node dissection after positive sentinel lymph node biopsy (SLNB). Two radiologists independently reassessed all MRI exams. Axillary ultrasound findings were retrospectively collected. Probability of advanced axillary nodal disease (pN2-3) given clinically node negative (cN0) or limited (cN1) findings was calculated, with corresponding negative predictive value (NPV) to exclude pN2-3 and positive predictive value (PPV) to identify axillary nodal disease. Histopathology served as gold standard. Results: A total of 377 cases resulted in 81.4% no, 14.4% limited and 4.2% advanced axillary nodal disease at final histopathology. Probability of pN2-3 given cN0 for breast MRI and axillary ultrasound was 0.7–0.9% versus 1.5% and probability of pN2-3 given cN1 was 11.6–15.4% versus 29.0%. When cN1 on breast MRI was observed, PPV to identify positive axillary nodal disease was 50.7% and 59.0%. Conclusions: Evaluation of axillary nodal status on standard breast MRI is comparable to dedicated axillary ultrasound in breast cancer patients. In patients who underwent preoperative standard breast MRI, axillary ultrasound is only required in case of suspicious nodal findings on MRI.

  7. Multicenter prospective study of magnetic resonance imaging prior to breast-conserving surgery for breast cancer.

    Science.gov (United States)

    Liu, Qian; Liu, Yinhua; Xu, Ling; Duan, Xuening; Li, Ting; Qin, Naishan; Kang, Hua; Jiang, Hongchuan; Yang, Deqi; Qu, Xiang; Jiang, Zefei; Yu, Chengze

    2014-01-01

    This multicenter prospective study aimed to assess the utility of dynamic enhanced magnetic resonance imaging (MRI) prior to breast-conserving surgery for breast cancer. The research subjects were drawn from patients with primary early resectable breast cancer treated in the breast disease centers of six three-level hospitals in Beijing from 1 January 2010 to 31 December 2012. The participants were allocated to a breast-conserving surgery group (breast-conserving group) or a total mastectomy group (total mastectomy group). Enhanced MRI was used to measure breast volume, longest diameter of tumor and tumor volume. The correlations between these measurements and those derived from histopathologic findings were assessed. The relationships between the success rate of breast-conserving surgery and MRI- and pathology-based measurement results were statistically analyzed in the breast-conserving group. The study included 461 cases in the total mastectomy group and 195 in the breast-conserving group. Allocation to these groups was based on clinical indications and patient preferences. The cut-off for concurrence between MRI- and pathology-based measurements of the longest diameter of tumor was set at 0.3 cm. In the total mastectomy group, the confidence interval for 95% concurrence of these measurements was 35.41%-44.63%. Correlation coefficients for MRI and histopathology-based measurements of breast volume, tumor volume and tumor volume/breast volume ratio were r = 0.861, 0.569, and 0.600, respectively (all P surgery were 100% and 88.54%, respectively. There were significant correlations between dynamic enhanced MRI- and histopathology-based measurements of the longest diameter of breast lesions, breast and tumor volumes, and breast volume/tumor volume ratios. Preoperative MRI examination improves the success rate of breast-conserving surgery.

  8. Full automatic fiducial marker detection on coil arrays for accurate instrumentation placement during MRI guided breast interventions

    Science.gov (United States)

    Filippatos, Konstantinos; Boehler, Tobias; Geisler, Benjamin; Zachmann, Harald; Twellmann, Thorsten

    2010-02-01

    With its high sensitivity, dynamic contrast-enhanced MR imaging (DCE-MRI) of the breast is today one of the first-line tools for early detection and diagnosis of breast cancer, particularly in the dense breast of young women. However, many relevant findings are very small or occult on targeted ultrasound images or mammography, so that MRI guided biopsy is the only option for a precise histological work-up [1]. State-of-the-art software tools for computer-aided diagnosis of breast cancer in DCE-MRI data offer also means for image-based planning of biopsy interventions. One step in the MRI guided biopsy workflow is the alignment of the patient position with the preoperative MR images. In these images, the location and orientation of the coil localization unit can be inferred from a number of fiducial markers, which for this purpose have to be manually or semi-automatically detected by the user. In this study, we propose a method for precise, full-automatic localization of fiducial markers, on which basis a virtual localization unit can be subsequently placed in the image volume for the purpose of determining the parameters for needle navigation. The method is based on adaptive thresholding for separating breast tissue from background followed by rigid registration of marker templates. In an evaluation of 25 clinical cases comprising 4 different commercial coil array models and 3 different MR imaging protocols, the method yielded a sensitivity of 0.96 at a false positive rate of 0.44 markers per case. The mean distance deviation between detected fiducial centers and ground truth information that was appointed from a radiologist was 0.94mm.

  9. MRI and pathological features of different molecular subtypes of breast cancers

    International Nuclear Information System (INIS)

    Yu Yang; Huo Tianlong; Lai Yunyao; Hong Nan

    2014-01-01

    Objective: To investigate the MRI and pathological features of different molecular subtypes of breast cancer. Methods: The data of 202 patients who underwent primary breast cancer resection were retrospectively reviewed. All of the patients had MRI preoperatively. The molecular subtypes of breast cancer defined by immunohistochemistry were classified as basal-like, luminal and HER-2 overexpression. Morphology (including mass or non-mass like enhancement, shape and margin of masses, unifocal or multifocal masses) and enhancement characteristics on MRI, histologic types and grades of tumors were analyzed with Chi-square test, exact test, Fisher exact test, Kruskal-Wallis H test, and Wilcoxon test. Results: Among the 202 patients, 34 were basal-like, 144 were luminal and 24 were HER-2 overexpression. The number of mass cases in each subtype was 29, 133 and 19 respectively,making no significant difference (χ 2 =4.136, P=0.126). As for the shape of basal-like lesions,8 were round,19 were lobular and 2 were irregular, while this distribution was 23, 58, 52 in luminal subtype and 1, 11, 7 in HER-2 overexpression subtype (χ 2 =13.391, P<0.05). The margin was also strikingly different among three groups (smooth, spiculate, irregular): 20, 5, 4 respectively in basal-like, 27, 53, 53 respectively in luminal, and 4, 7, 8 respectively in HER-2 overexpression (χ 2 =28.515, P<0.01). 52.6% (10/19) of HER-2 overexpression cases were multifocal, while only 6.9% (2/29) of luminal and 8.0% (24/133) of basal-like ones were multifocal (χ 2 =16.140, P<0.01). Characteristics in dynamic contrast-enhanced MRI were statistically different, with homogeneous, heterogeneous, and rim enhancement 0, 13, 16 respectively in basal-like cases, 28, 93, 11 respectively in luminal cases and 2, 11, 6 respectively in HER-2 overexpression cases (P<0.01). However, the difference for enhancement curve did not reach significance (P =0.457). Histologic types were significantly different among molecular

  10. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting

    NARCIS (Netherlands)

    van der Waal, Daniëlle; den Heeten, Gerard J.; Pijnappel, Ruud M.; Schuur, Klaas H.; Timmers, Johanna M. H.; Verbeek, André L. M.; Broeders, Mireille J. M.

    2015-01-01

    The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of personalised

  11. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening Setting

    NARCIS (Netherlands)

    Waal, D. van der; Heeten, GJ. den; Pijnappel, R.M.; Schuur, K.H.; Timmers, J.M.; Verbeek, A.L.; Broeders, M.J.

    2015-01-01

    INTRODUCTION: The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of

  12. Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software : A Cross-Sectional Study in a Breast Cancer Screening Setting

    NARCIS (Netherlands)

    van der Waal, Danielle; den Heeten, Gerard J.; Pijnappel, Ruud M.; Schuur, Klaas H.; Timmers, Johanna M. H.; Verbeek, Andre L. M.; Broeders, Mireille J. M.

    2015-01-01

    Introduction The objective of this study is to compare different methods for measuring breast density, both visual assessments and automated volumetric density, in a breast cancer screening setting. These measures could potentially be implemented in future screening programmes, in the context of

  13. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  14. Role of MRI in differentiating benign from malignant breast lesions ...

    African Journals Online (AJOL)

    Mohamed Ahmed Youssef

    2017-02-15

    Feb 15, 2017 ... renal dysfunction or previous reactions to contrast agents and will relieve the cost of examination.4,5. The aim of the study was to evaluate the role of the magnetic resonance imaging in differentiation of benign from malignant breast lesions using dynamic contrast enhanced MRI (DCE-MRI) and diffusion ...

  15. Extra-mammary findings in breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Pierluigi; Costantini, M.; Belli, P.; Giuliani, M.; Bufi, E.; Fubelli, R.; Distefano, D.; Romani, M.; Bonomo, L. [Catholic University - Policlinic A. Gemelli, Department of Bio-Imaging and Radiological Sciences, Rome (Italy)

    2011-11-15

    Incidental extra-mammary findings in breast Magnetic Resonance Imaging (MRI) may be benign in nature, but may also represent a metastasis or another important lesion. We aimed to analyse the prevalence and clinical relevance of these unexpected findings. A retrospective review of 1535 breast MRIs was conducted. Only axial sequences were reassessed. Confirmation examinations were obtained in all cases. 285 patients had a confirmed incidental finding, which were located in the liver (51.9%), lung (11.2%), bone (7%), mediastinal lymph nodes (4.2%) or consisted of pleural/pericardial effusion (15.4%). 20.4% of incidental findings were confirmed to be malignant. Positive predictive value for MRI to detect a metastatic lesion was high if located within the bone (89%), lymph nodes (83%) and lung (59%), while it was low if located within the liver (9%) or if it consisted of pleural/pericardial effusion (6%). The axial enhanced sequence showed superior sensitivity to unenhanced images in detecting metastatic lesions, especially if only smaller ({<=}10 mm.) lesions were considered. The prevalence of metastatic incidental extra-mammary findings is not negligible. Particular attention should be to incidental findings located within the lung, bone and mediastinal lymph nodes. (orig.)

  16. Breast Density and Breast Cancer Incidence in the Lebanese Population: Results from a Retrospective Multicenter Study

    Directory of Open Access Journals (Sweden)

    Christine Salem

    2017-01-01

    Full Text Available Purpose. To study the distribution of breast mammogram density in Lebanese women and correlate it with breast cancer (BC incidence. Methods. Data from 1,049 women who had screening or diagnostic mammography were retrospectively reviewed. Age, menopausal status, contraceptives or hormonal replacement therapy (HRT, parity, breastfeeding, history of BC, breast mammogram density, and final BI-RADS assessment were collected. Breast density was analyzed in each age category and compared according to factors that could influence breast density and BC incidence. Results. 120 (11.4% patients had BC personal history with radiation and/or chemotherapy; 66 patients were postmenopausal under HRT. Mean age was 52.58±11.90 years. 76.4% of the patients (30–39 years had dense breasts. Parity, age, and menopausal status were correlated to breast density whereas breastfeeding and personal/family history of BC and HRT were not. In multivariate analysis, it was shown that the risk of breast cancer significantly increases 3.3% with age (P=0.005, 2.5 times in case of menopause (P=0.004, and 1.4 times when breast density increases (P=0.014. Conclusion. Breast density distribution in Lebanon is similar to the western society. Similarly to other studies, it was shown that high breast density was statistically related to breast cancer, especially in older and menopausal women.

  17. Postmortem validation of breast density using dual-energy mammography

    OpenAIRE

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dua...

  18. Changes in mammographic density and breast cancer risk

    NARCIS (Netherlands)

    Lokate, A.J.M.

    2012-01-01

    Breast cancer is the most frequently occurring cancer among women worldwide. One of the most important risk factors for breast cancer is high mammographic density. Mammographic density represents the amount of fibroglandular tissue relative to the fat tissue in the breast. Women with >75% of their

  19. A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui; Liu, Yiping; Qiu, Tianshuang [Department of Biomedical Engineering, Dalian University of Technology, Dalian 116024 (China); Zhao, Zuowei, E-mail: liuhui@dlut.edu.cn [Second Affiliated Hospital, Dalian Medical University, Dalian 116027 (China); Zhang, Lina [Department of Radiology, First Affiliated Hospital, Dalian Medical University, Dalian 116027 (China)

    2014-08-15

    Purpose: To develop and evaluate a computerized semiautomatic segmentation method for accurate extraction of three-dimensional lesions from dynamic contrast-enhanced magnetic resonance images (DCE-MRIs) of the breast. Methods: The authors propose a new background distribution-based active contour model using level set (BDACMLS) to segment lesions in breast DCE-MRIs. The method starts with manual selection of a region of interest (ROI) that contains the entire lesion in a single slice where the lesion is enhanced. Then the lesion volume from the volume data of interest, which is captured automatically, is separated. The core idea of BDACMLS is a new signed pressure function which is based solely on the intensity distribution combined with pathophysiological basis. To compare the algorithm results, two experienced radiologists delineated all lesions jointly to obtain the ground truth. In addition, results generated by other different methods based on level set (LS) are also compared with the authors’ method. Finally, the performance of the proposed method is evaluated by several region-based metrics such as the overlap ratio. Results: Forty-two studies with 46 lesions that contain 29 benign and 17 malignant lesions are evaluated. The dataset includes various typical pathologies of the breast such as invasive ductal carcinoma, ductal carcinomain situ, scar carcinoma, phyllodes tumor, breast cysts, fibroadenoma, etc. The overlap ratio for BDACMLS with respect to manual segmentation is 79.55% ± 12.60% (mean ± s.d.). Conclusions: A new active contour model method has been developed and shown to successfully segment breast DCE-MRI three-dimensional lesions. The results from this model correspond more closely to manual segmentation, solve the weak-edge-passed problem, and improve the robustness in segmenting different lesions.

  20. Real-time MRI navigated US: Role in diagnosis and guided biopsy of incidental breast lesions and axillary lymph nodes detected on breast MRI but not on second look US

    Energy Technology Data Exchange (ETDEWEB)

    Pons, Elena Pastor, E-mail: elenapastorpons@gmail.com; Azcón, Francisco Miras, E-mail: frmiaz00@gmail.com; Casas, María Culiañez, E-mail: mariacc1980@gmail.com; Meca, Salvador Martínez, E-mail: isalvaa@hotmail.com; Espona, José Luis García, E-mail: gespona@hotmail.com

    2014-06-15

    Objectives: To prospectively evaluate the accuracy of real-time ultrasound combined with supine-MRI using volume navigation technique (RtMR-US) in diagnosis and biopsy of incidental breast lesions (ILSM) and axillary lymph nodes (LNSM) suspicious of malignancy on contrast enhanced magnetic resonance imaging (CE-MRI). Materials and methods: Five hundred and seventy-seven women were examined using breast CE-MRI. Those with incidental breast lesions not identified after second-look ultrasound (US) were recruited for RtMR-US. Biopsy was performed in ILSM. Breast lesions were categorized with BI-RADS system and Fisher’ exact test. Axillary lymph nodes morphology was described. To assess efficacy of RtMR-US, diagnostic accuracy, sensitivity, specificity, detection rate and Kappa index of conventional-US and RtMR-US were calculated. Results: Forty-three lesions were detected on CE-MRI before navigation. Eighteen were carcinomas and 25 ILSM. Of these, 21 underwent a RtMR-US. Detection rate on RtMR-US (90.7%) was higher than on conventional-US (43%) (p < 0.001). Agreement between both techniques was low (k = 0.138). Twenty ILSM and 2 LNSM were biopsied. Sixty-five percent were benign (100% of BI-RADS3 and 56% of BI-RADS4-5). Diagnostic performance of RtMR-US identifying malignant nodules for overall lesions and for the subgroup of ILSM was respectively: sensitivity 96.3% and 100%, specificity 18.8% and 30.7%, positive predictive value 66.7% and 43.7%, negative predictive value 75% and 100%. In addition RtMR-US enabled biopsy of 2 metastatic lymph nodes. Conclusions: Real time-US with supine-MRI using a volume navigation technique increases the detection of ILSM. RtMR-US may be used to detect occult breast carcinomas and to assess cancer extension, preventing unnecessary MRI-guided biopsies and sentinel lymph node biopsies. Incidental lesions BI-RADS 3 non-detected on conventional-US are probably benign.

  1. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    Science.gov (United States)

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. MRI features of intraductal papilloma of the breast: sheep in wolf's clothing?

    International Nuclear Information System (INIS)

    Kurz, Kathinka D; Roy, Sumit; Saleh, Andreas; Diallo-Danebrock, Raihana; Skaane, Per

    2011-01-01

    Background: Intraductal papillomas often present as small, smooth masses, dilated ducts or microcalcifications at mammography and as smooth, hypoechoic masses at sonography. At magnetic resonance imaging (MRI), intraductal papillomas often present as small smooth masses, however, often with strong enhancement with type 2 or 3 time intensity curves. The result of the MR analysis is therefore not infrequently inconclusive in order to characterize the mass as benign or malignant. Purpose: To characterize the appearance of intraductal papillomas of the breast at MRI, and determine whether the application of diagnostic rules described in literature could contribute to correctly classifying the lesions as benign. Material and Methods: Twenty patients with histologically proven intraductal papillomas were included. Two radiologists independently reviewed the MR images of the breast. The BI-RADS nomenclature was used to describe morphology and contrast-enhancement kinetics. Interobserver agreement in the interpretation of the MR images by the two investigators was performed. Kappa coefficient was calculated as index for the level of agreement. Subsequently, three sets of diagnostic rules, including the Goettinger score described by Fischer and the interpretation flowcharts according to Kinkel and to Tozaki were applied to characterize whether a biopsy should be recommended or not. Results: All papillomas presented as masses on dynamic contrast-enhanced MRI. Only five papillomas showed a round, oval, or lobulated shape combined with smooth margins and continuous rise of the time intensity curve. Using the Goettinger score, biopsy would be recommended in 16 patients. Based on the interpretation flowcharts of Kinkel and of Tozaki, an additional 13 and 10 papillomas, respectively, were correctly classified as benign. Dilated ducts were visible in 10 patients. The interobserver agreement was good or excellent for all included variables. Conclusion: Including systematic analysis

  3. Dynamic MRI study for breast tumors

    International Nuclear Information System (INIS)

    Seki, Tsuneaki

    1990-01-01

    Application of MRI for diagnosis of breast tumors was retrospectively examined in 103 consecutive cases. Contrast enhancement, mostly by dynamic study, was performed in 83 cases using Gd-DTPA and 0.5 T superconductive apparatus. Results were compared to those of mammography and sonography. On dynamic study, carcinoma showed abrupt rise of signal intensity with clear-cut peak formation in early phase, while benign fibroadenoma showed slow rise of signal intensity and prolonged enhancement without peak formation. In 12 of 33 carcinomas (33%), peripheral ring enhancement was noted reflecting vascular stroma of histologic sections. All fibroadenomas showed homogenous enhancement without peripheral ring. In MRI, sensitivity, specificity, and accuracy were 86%, 96%, 91%. In mammography 82%, 95%, 87% and in ultrasonography 91%, 95%, 93%. Although MRI should not be regarded as routine diagnostic procedure because of expense and limited availability, it may afford useful additional information when standard mammographic findings are not conclusive. (author)

  4. Impact of menopausal status on background parenchymal enhancement and fibroglandular tissue on breast MRI

    International Nuclear Information System (INIS)

    King, Valencia; Gu, Yajia; Kaplan, Jennifer B.; Morris, Elizabeth A.; Brooks, Jennifer D.; Pike, Malcolm C.

    2012-01-01

    To evaluate the effect of menopausal status on the background parenchymal enhancement (BPE) and amount of fibroglandular tissue (FGT) on breast MRI. Retrospective review identified 1,130 women who underwent screening breast MRI between July and November 2010. In 28 of these women, breast MRI was performed both at one time point while pre- and one time point while post-menopausal (median interval 49 months). Two independent readers blinded to menopausal status used categorical scales to rate BPE (minimal/mild/moderate/marked) and FGT (fatty/scattered/heterogeneously dense/dense). Consensus was reached when there was disagreement. The sign test was used to assess changes in rating categories, and the Spearman rank and Fisher's exact tests were used to measure correlations and associations between variables. Significant proportions of women demonstrated decreases in BPE and FGT on post-menopausal breast MRI (P = 0.0001 and P = 0.0009). BPE category was unchanged in 39 % (11/28) and decreased in 61 % (17/28) of women. FGT category was unchanged in 61 % (17/28) and decreased in 39 % (11/28) of women. Age, reason for menopause, or interval between MRIs had no significant impact on changes in BPE and FGT. On MRI, BPE, and FGT decrease after menopause in significant proportions of women; BPE decreases more than FGT. (orig.)

  5. Integrated radiomic framework for breast cancer and tumor biology using advanced machine learning and multiparametric MRI.

    Science.gov (United States)

    Parekh, Vishwa S; Jacobs, Michael A

    2017-01-01

    Radiomics deals with the high throughput extraction of quantitative textural information from radiological images that not visually perceivable by radiologists. However, the biological correlation between radiomic features and different tissues of interest has not been established. To that end, we present the radiomic feature mapping framework to generate radiomic MRI texture image representations called the radiomic feature maps (RFM) and correlate the RFMs with quantitative texture values, breast tissue biology using quantitative MRI and classify benign from malignant tumors. We tested our radiomic feature mapping framework on a retrospective cohort of 124 patients (26 benign and 98 malignant) who underwent multiparametric breast MR imaging at 3 T. The MRI parameters used were T1-weighted imaging, T2-weighted imaging, dynamic contrast enhanced MRI (DCE-MRI) and diffusion weighted imaging (DWI). The RFMs were computed by convolving MRI images with statistical filters based on first order statistics and gray level co-occurrence matrix features. Malignant lesions demonstrated significantly higher entropy on both post contrast DCE-MRI (Benign-DCE entropy: 5.72 ± 0.12, Malignant-DCE entropy: 6.29 ± 0.06, p  = 0.0002) and apparent diffusion coefficient (ADC) maps as compared to benign lesions (Benign-ADC entropy: 5.65 ± 0.15, Malignant ADC entropy: 6.20 ± 0.07, p  = 0.002). There was no significant difference between glandular tissue entropy values in the two groups. Furthermore, the RFMs from DCE-MRI and DWI demonstrated significantly different RFM curves for benign and malignant lesions indicating their correlation to tumor vascular and cellular heterogeneity respectively. There were significant differences in the quantitative MRI metrics of ADC and perfusion. The multiview IsoSVM model classified benign and malignant breast tumors with sensitivity and specificity of 93 and 85%, respectively, with an AUC of 0.91.

  6. The role of cone-beam breast-CT for breast cancer detection relative to breast density

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne; Uhlig, Johannes; Fintel, Eva von; Stahnke, Vera; Lotz, Joachim [University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany); Luftner-Nagel, Susanne; Fischer, Uwe [Diagnostic Breast Center Goettingen, Goettingen (Germany); Zapf, Antonia [University Medical Center Goettingen, Department of Medical Statistics, Goettingen (Germany); Surov, Alexey [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2017-12-15

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. (orig.)

  7. The correlation of background parenchymal enhancement in the contralateral breast with patient and tumor characteristics of MRI-screen detected breast cancers.

    Science.gov (United States)

    Vreemann, Suzan; Gubern-Mérida, Albert; Borelli, Cristina; Bult, Peter; Karssemeijer, Nico; Mann, Ritse M

    2018-01-01

    Higher background parenchymal enhancement (BPE) could be used for stratification of MRI screening programs since it might be related to a higher breast cancer risk. Therefore, the purpose of this study is to correlate BPE to patient and tumor characteristics in women with unilateral MRI-screen detected breast cancer who participated in an intermediate and high risk screening program. As BPE in the affected breast may be difficult to discern from enhancing cancer, we assumed that BPE in the contralateral breast is a representative measure for BPE in women with unilateral breast cancer. This retrospective study was approved by our local institutional board and a waiver for consent was granted. MR-examinations of women with unilateral breast cancers screen-detected on breast MRI were evaluated by two readers. BPE in the contralateral breast was rated according to BI-RADS. Univariate analyses were performed to study associations. Observer variability was computed. Analysis included 77 breast cancers in 76 patients (age: 48±9.8 years), including 62 invasive and 15 pure ductal carcinoma in-situ cases. A negative association between BPE and tumor grade (p≤0.016) and a positive association with progesterone status (p≤0.021) was found. The correlation was stronger when only considering invasive disease. Inter-reader agreement was substantial. Lower BPE in the contralateral breast in women with unilateral breast cancer might be associated to higher tumor grade and progesterone receptor negativity. Great care should be taken using BPE for stratification of patients to tailored screening programs.

  8. Arterial spin labelling perfusion MRI of breast cancer using FAIR TrueFISP: Initial results

    International Nuclear Information System (INIS)

    Buchbender, S.; Obenauer, S.; Mohrmann, S.; Martirosian, P.; Buchbender, C.; Miese, F.R.; Wittsack, H.J.; Miekley, M.; Antoch, G.; Lanzman, R.S.

    2013-01-01

    Aim: To assess the feasibility of an unenhanced, flow-sensitive, alternating inversion recovery-balanced steady-state free precession (FAIR TrueFISP) arterial spin labelling (ASL) magnetic resonance imaging (MRI) technique for quantification of breast cancer perfusion. Materials and methods: Eighteen untreated breast tumour patients (mean age 53 ± 17 years, range 30–68 years) and four healthy controls (mean age 51 ± 14 years, range 33–68 years) were enrolled in this study and were imaged using a clinical 1.5 T MRI machine. Perfusion measurements were performed using a coronal single-section ASL FAIR TrueFISP technique in addition to a routine breast MRI examination. T1 relaxation time of normal breast parenchyma was determined in four healthy volunteers using the variable flip angle approach. The definitive diagnosis was obtained at histology after biopsy or surgery and was available for all patients. Results: ASL perfusion was successfully acquired in 13 of 18 tumour patients and in all healthy controls. The mean ASL perfusion of invasive ductal carcinoma tissue was significantly higher (88.2 ± 39.5 ml/100 g/min) compared to ASL perfusion of normal breast parenchyma (24.9 ± 12.7 ml/100 g/min; p < 0.05) and invasive lobular carcinoma (30.5 ± 4.3 ml/100 g/min; p < 0.05). No significant difference was found between the mean ASL perfusion of normal breast parenchyma and invasive lobular carcinoma tissue (p = 0.97). Conclusion: ASL MRI enables quantification of breast cancer perfusion without the use of contrast material. However, its impact on diagnosis and therapy management of breast tumours has to be evaluated in larger patient studies

  9. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    Science.gov (United States)

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  10. Breast Density Legislation in New England: A Survey Study of Practicing Radiologists.

    Science.gov (United States)

    Lourenco, Ana P; DiFlorio-Alexander, Roberta M; Slanetz, Priscilla J

    2017-10-01

    This study aimed to assess radiologists' knowledge about breast density legislation as well as perceived practice changes resulting from the enactment of breast density legislation. This is an institutional review board-exempt anonymous email survey of 523 members of the New England Roentgen Ray Society. In addition to radiologist demographics, survey questions addressed radiologist knowledge of breast density legislation, knowledge of breast density as a risk factor for breast cancer, recommendations for supplemental screening, and perceived practice changes resulting from density notification legislation. Of the 523 members, 96 responded, yielding an 18% response rate. Seventy-three percent of respondents practiced in a state with breast density legislation. Sixty-nine percent felt that breast density notification increased patient anxiety about breast cancer, but also increased patient (74%) and provider (66%) understanding of the effect of breast density on mammographic sensitivity. Radiologist knowledge of the relative risk of breast cancer when comparing breasts of different density was variable. Considerable confusion and controversy regarding breast density persists, even among practicing radiologists. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Mammographic breast density patterns among a group of women in ...

    African Journals Online (AJOL)

    Introduction: Mammographic breast density is a measure of parenchymal breast patterns on film and in part a marker of cumulative exposure to oestrogen. The risk of breast cancer for women with increased density is up to six fold more than in women with less dense tissues. The pattern of mammographic breast density ...

  12. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI; Multiparametrische und molekulare Bildgebung von Brusttumoren mit MRT und PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Memorial Sloan-Kettering Cancer Center, Department of Radiology, Molecular Imaging and Therapy Service, New York (United States); State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Marino, M.A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Policlinico Universitario G. Martino, University of Messina, Department of Biomedical Sciences and Morphologic and Functional Imaging, Messina (Italy); Meyer-Baese, A. [State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Helbich, T.H. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria)

    2016-07-15

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ({sup 1}H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ({sup 23}Na MRI), phosphorus spectroscopy ({sup 31}P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [German] Die Magnetresonanztomographie (MRT) der Brust ist ein etabliertes nichtinvasives bildgebendes Verfahren mit vielfaeltigen Indikationen. In den letzten Jahren wurden zahlreiche funktionelle MRT- und Positronenemissionstomographie(PET)-Parameter in der Brustbildgebung evaluiert, und ihre kombinierte Anwendung ist als multiparametrische Bildgebung definiert. Bisherige Daten legen nahe, dass die multiparametrische Bildgebung mit MRT und PET

  13. Correlation between MRI results and intraoperative findings in patients with silicone breast implants.

    Science.gov (United States)

    Lindenblatt, Nicole; El-Rabadi, Karem; Helbich, Thomas H; Czembirek, Heinrich; Deutinger, Maria; Benditte-Klepetko, Heike

    2014-01-01

    Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21-72) years, with a mean duration of implantation of 3.8 (range 1-28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal.

  14. Automatic atlas based electron density and structure contouring for MRI-based prostate radiation therapy on the cloud

    International Nuclear Information System (INIS)

    Dowling, J A; Burdett, N; Chandra, S; Rivest-Hénault, D; Ghose, S; Salvado, O; Fripp, J; Greer, P B; Sun, J; Parker, J; Pichler, P; Stanwell, P

    2014-01-01

    Our group have been developing methods for MRI-alone prostate cancer radiation therapy treatment planning. To assist with clinical validation of the workflow we are investigating a cloud platform solution for research purposes. Benefits of cloud computing can include increased scalability, performance and extensibility while reducing total cost of ownership. In this paper we demonstrate the generation of DICOM-RT directories containing an automatic average atlas based electron density image and fast pelvic organ contouring from whole pelvis MR scans.

  15. Automatic Atlas Based Electron Density and Structure Contouring for MRI-based Prostate Radiation Therapy on the Cloud

    Science.gov (United States)

    Dowling, J. A.; Burdett, N.; Greer, P. B.; Sun, J.; Parker, J.; Pichler, P.; Stanwell, P.; Chandra, S.; Rivest-Hénault, D.; Ghose, S.; Salvado, O.; Fripp, J.

    2014-03-01

    Our group have been developing methods for MRI-alone prostate cancer radiation therapy treatment planning. To assist with clinical validation of the workflow we are investigating a cloud platform solution for research purposes. Benefits of cloud computing can include increased scalability, performance and extensibility while reducing total cost of ownership. In this paper we demonstrate the generation of DICOM-RT directories containing an automatic average atlas based electron density image and fast pelvic organ contouring from whole pelvis MR scans.

  16. Breast density and mode of detection in relation to breast cancer specific survival: a cohort study

    International Nuclear Information System (INIS)

    Olsson, Åsa; Sartor, Hanna; Borgquist, Signe; Zackrisson, Sophia; Manjer, Jonas

    2014-01-01

    The aim of this study was to examine breast density in relation to breast cancer specific survival and to assess if this potential association was modified by mode of detection. An additional aim was to study whether the established association between mode of detection and survival is modified by breast density. The study included 619 cases from a prospective cohort, The Malmö Diet and Cancer Study. Breast density estimated qualitatively, was analyzed in relation to breast cancer death, in non-symptomatic and symptomatic women, using Cox regression calculating hazard ratios (HR) with 95% confidence intervals. Adjustments were made in several steps for; diagnostic age, tumour size, axillary lymph node involvement, grade, hormone receptor status, body mass index (baseline), diagnostic period, use of hormone replacement therapy at diagnosis and mode of detection. Detection mode in relation to survival was analyzed stratified for breast density. Differences in HR following different adjustments were analyzed by Freedmans%. After adjustment for age and other prognostic factors, women with dense, as compared to fatty breasts, had an increased risk of breast cancer death, HR 2.56:1.07-6.11, with a statistically significant trend over density categories, p = 0.04. In the stratified analysis, the effect was less pronounced in non-symptomatic women, HR 2.04:0.49-8.49 as compared to symptomatic, HR 3.40:1.06-10.90. In the unadjusted model, symptomatic women had a higher risk of breast cancer death, regardless of breast density. Analyzed by Freedmans%, age, tumour size, lymph nodes, grade, diagnostic period, ER and PgR explained 55.5% of the observed differences in mortality between non-symptomatic and symptomatic cases. Additional adjustment for breast density caused only a minor change. High breast density at diagnosis may be associated with decreased breast cancer survival. This association appears to be stronger in women with symptomatic cancers but breast density could

  17. Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ruschin, Mark, E-mail: Mark.Ruschin@sunnybrook.ca; Chin, Lee; Ravi, Ananth; McCann, Claire [Department of Medical Physics, Sunnybrook Odette Cancer Centre, Toronto, Ontario M4N 3M5, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Davidson, Sean R. H. [Techna Institute, University Health Network, Toronto, Ontario M5G 1P5 (Canada); Phounsy, William [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Yoo, Tae Sun [Institute of Health Policy, University of Toronto, Toronto, Ontario M5T 3M6 (Canada); Pignol, Jean-Philippe [Department of Radiation Oncology, Erasmus MC Cancer Institute, 3075 EA Rotterdam (Netherlands)

    2016-05-15

    Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM) dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD

  18. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  19. Impact of menopausal status on background parenchymal enhancement and fibroglandular tissue on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    King, Valencia [Memorial Sloan-Kettering Cancer Center, Department of Radiology, Breast Imaging Section, New York, NY (United States); Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Gu, Yajia [Fudan University Shanghai Cancer Center, Department of Radiology, Shanghai (China); Fudan University, Department of Oncology, Shanghai Medical College, Shanghai (China); Kaplan, Jennifer B.; Morris, Elizabeth A. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, Breast Imaging Section, New York, NY (United States); Brooks, Jennifer D.; Pike, Malcolm C. [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States)

    2012-12-15

    To evaluate the effect of menopausal status on the background parenchymal enhancement (BPE) and amount of fibroglandular tissue (FGT) on breast MRI. Retrospective review identified 1,130 women who underwent screening breast MRI between July and November 2010. In 28 of these women, breast MRI was performed both at one time point while pre- and one time point while post-menopausal (median interval 49 months). Two independent readers blinded to menopausal status used categorical scales to rate BPE (minimal/mild/moderate/marked) and FGT (fatty/scattered/heterogeneously dense/dense). Consensus was reached when there was disagreement. The sign test was used to assess changes in rating categories, and the Spearman rank and Fisher's exact tests were used to measure correlations and associations between variables. Significant proportions of women demonstrated decreases in BPE and FGT on post-menopausal breast MRI (P = 0.0001 and P = 0.0009). BPE category was unchanged in 39 % (11/28) and decreased in 61 % (17/28) of women. FGT category was unchanged in 61 % (17/28) and decreased in 39 % (11/28) of women. Age, reason for menopause, or interval between MRIs had no significant impact on changes in BPE and FGT. On MRI, BPE, and FGT decrease after menopause in significant proportions of women; BPE decreases more than FGT. (orig.)

  20. DCIS of the breast: the value of preoperative MRI

    International Nuclear Information System (INIS)

    Doyle, Anthony J.; Prakash, Sharath; Wang, Kaye; Cranshaw, Isaac; Taylor, Eletha; Oldfield, Robin

    2016-01-01

    Ductal carcinoma in situ (DCIS) of the breast is commonly treated surgically. The intent of this study was to evaluate whether preoperative MRI could add to mammography in predicting the extent of the disease. A series of patients with DCIS attending our surgical clinic for preoperative assessment were offered MRI as part of a prospective study. The extent of the disease indicated by mammography and MRI was compared with histopathology after definitive treatment. The null hypothesis was that MRI does not add to mammography in accurately predicting disease extent. Fifty patients make up the basis of this report. Mammography was concordant with the pathology in 31/50. MRI and mammography combined were concordant in 43/50. This is a statistically significant difference (P = 0.01, Fisher's exact test). Upstaging to mastectomy by MRI was correct in 7/8 patients, but downstaging was correct in only 2/4. The null hypothesis is rejected. MRI does add to mammography in accurately predicting the extent of DCIS. Upstaging by MRI is usually reliable.

  1. Comparison of neurite density measured by MRI and histology after TBI.

    Directory of Open Access Journals (Sweden)

    Shiyang Wang

    Full Text Available Functional recovery after brain injury in animals is improved by marrow stromal cells (MSC which stimulate neurite reorganization. However, MRI measurement of neurite density changes after injury has not been performed. In this study, we investigate the feasibility of MRI measurement of neurite density in an animal model of traumatic brain injury (TBI with and without MSC treatment.Fifteen male Wistar rats, were treated with saline (n = 6 or MSCs (n = 9 and were sacrificed at 6 weeks after controlled cortical impact (CCI. Healthy non-CCI rats (n = 5, were also employed. Ex-vivo MRI scans were performed two days after the rats were sacrificed. Multiple-shell hybrid diffusion imaging encoding scheme and spherical harmonic expansion of a two-compartment water diffusion displacement model were used to extract neurite related parameters. Bielshowski and Luxol Fast blue was used for staining axons and myelin, respectively. Modified Morris water maze and neurological severity score (mNSS test were performed for functional evaluation. The treatment effects, the correlations between neurite densities measured by MRI and histology, and the correlations between MRI and functional variables were calculated by repeated measures analysis of variance, the regression correlation analysis tests, and spearman correlation coefficients.Neurite densities exhibited a significant correlation (R(2>0.80, p<1E-20 between MRI and immuno-histochemistry measurements with 95% lower bound of the intra-correlation coefficient (ICC as 0.86. The conventional fractional anisotropy (FA correlated moderately with histological neurite density (R(2 = 0.59, P<1E-5 with 95% lower bound of ICC as 0.76. MRI data revealed increased neurite reorganization with MSC treatment compared with saline treatment, confirmed by histological data from the same animals. mNSS were significantly correlated with MRI neurite density in the hippocampus region.The present studies

  2. Quantitative assessment of breast density from digitized mammograms into Tabar's patterns

    Energy Technology Data Exchange (ETDEWEB)

    Jamal, N [Medical Technology Division, Malaysian Institute for Nuclear Technology Research (MINT) 43000 Kajang (Malaysia); Ng, K-H [Department of Radiology, University of Malaya, 50603 Kuala Lumpur (Malaysia); Looi, L-M [Department of Pathology, University of Malaya, 50603 Kuala Lumpur (Malaysia); McLean, D [Medical Physics Department, Westmead Hospital, Sydney, NSW 2145 (Australia); Zulfiqar, A [Department of Radiology, Hospital Universiti Kebangsaan Malaysia, 56000 Malaysia, Kuala Lumpur, Malaysia (Malaysia); Tan, S-P [Department of Radiology, Hospital Universiti Kebangsaan Malaysia, 56000 Malaysia, Kuala Lumpur, Malaysia (Malaysia); Liew, W-F [Department of Radiology, Hospital Universiti Kebangsaan Malaysia, 56000 Malaysia, Kuala Lumpur, Malaysia (Malaysia); Shantini, A [Department of Radiology, Kuala Lumpur Hospital, 50586 Kuala Lumpur (Malaysia); Ranganathan, S [Department of Radiology, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2006-11-21

    We describe a semi-automated technique for the quantitative assessment of breast density from digitized mammograms in comparison with patterns suggested by Tabar. It was developed using the MATLAB-based graphical user interface applications. It is based on an interactive thresholding method, after a short automated method that shows the fibroglandular tissue area, breast area and breast density each time new thresholds are placed on the image. The breast density is taken as a percentage of the fibroglandular tissue to the breast tissue areas. It was tested in four different ways, namely by examining: (i) correlation of the quantitative assessment results with subjective classification, (ii) classification performance using the quantitative assessment technique, (iii) interobserver agreement and (iv) intraobserver agreement. The results of the quantitative assessment correlated well (r{sup 2} = 0.92) with the subjective Tabar patterns classified by the radiologist (correctly classified 83% of digitized mammograms). The average kappa coefficient for the agreement between the readers was 0.63. This indicated moderate agreement between the three observers in classifying breast density using the quantitative assessment technique. The kappa coefficient of 0.75 for intraobserver agreement reflected good agreement between two sets of readings. The technique may be useful as a supplement to the radiologist's assessment in classifying mammograms into Tabar's pattern associated with breast cancer risk.

  3. Computer-aided detection in breast MRI : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Dorrius, Monique D.; Jansen-van der Weide, Marijke C.; van Ooijen, Peter M. A.; Pijnappel, Ruud M.; Oudkerk, Matthijs

    To evaluate the additional value of computer-aided detection (CAD) in breast MRI by assessing radiologists' accuracy in discriminating benign from malignant breast lesions. A literature search was performed with inclusion of relevant studies using a commercially available CAD system with automatic

  4. Using deep learning to segment breast and fibroglandular tissue in MRI volumes

    NARCIS (Netherlands)

    Dalmis, M.U.; Litjens, G.J.; Holland, K.; Setio, A.A.A.; Mann, R.M.; Karssemeijer, N.; Gubern Merida, A.

    2017-01-01

    PURPOSE: Automated segmentation of breast and fibroglandular tissue (FGT) is required for various computer-aided applications of breast MRI. Traditional image analysis and computer vision techniques, such atlas, template matching, or, edge and surface detection, have been applied to solve this task.

  5. The diagnosis of breast implant rupture: MRI findings compared with findings at explantation

    International Nuclear Information System (INIS)

    Hoelmich, Lisbet R.; Vejborg, Ilse; Conrad, Carsten; Sletting, Susanne; McLaughlin, Joseph K.

    2005-01-01

    Study objective: The aim of this study was to evaluate the accuracy of Magnetic Resonance Imaging (MRI) as performed according to a strict study protocol in diagnosing rupture of silicone breast implants. Material and methods: The study population consisted of 64 women with 118 implants, who had participated in either one or two study MRI examinations, aiming at determining the prevalence and incidence of silent implant rupture, respectively, and who subsequently underwent explantation. Implant rupture status was determined by four independent readers and a consensus diagnosis of either rupture (intracapsular or extracapsular), possible rupture or intact implant was then obtained. Strict predetermined rupture criteria were applied as described in this report and findings at surgery were abstracted in a standardised manner and results compared. Results: At MRI, 66 implants were diagnosed as ruptured, nine as possibly ruptured and 43 as intact. Among the ruptured implants, 27 were categorized as extracapsular. At surgery, on average 297 days after the MRI, 65 of the 66 rupture diagnoses were confirmed, as were 20 of the cases with extracapsular silicone. Eight of the nine possibly ruptured implants were in fact ruptured at surgery. Thirty-four of the 43 intact implants were described as intact at surgery. When categorising possible ruptures as ruptures, there were one false positive and nine false negative rupture diagnoses at MRI yielding an accuracy of 92%, a sensitivity of 89%, and a specificity of 97%. Correspondingly, the predictive value of a positive MRI examination was 99% and the predictive value of a negative MRI examination was 79%. Conclusions: We conclude that MRI is highly accurate for identification of silicone breast implant rupture, with a high sensitivity and specificity when evaluation of images are based on presence of well-defined rupture criteria

  6. Breast Density Estimation with Fully Automated Volumetric Method: Comparison to Radiologists' Assessment by BI-RADS Categories.

    Science.gov (United States)

    Singh, Tulika; Sharma, Madhurima; Singla, Veenu; Khandelwal, Niranjan

    2016-01-01

    The objective of our study was to calculate mammographic breast density with a fully automated volumetric breast density measurement method and to compare it to breast imaging reporting and data system (BI-RADS) breast density categories assigned by two radiologists. A total of 476 full-field digital mammography examinations with standard mediolateral oblique and craniocaudal views were evaluated by two blinded radiologists and BI-RADS density categories were assigned. Using a fully automated software, mean fibroglandular tissue volume, mean breast volume, and mean volumetric breast density were calculated. Based on percentage volumetric breast density, a volumetric density grade was assigned from 1 to 4. The weighted overall kappa was 0.895 (almost perfect agreement) for the two radiologists' BI-RADS density estimates. A statistically significant difference was seen in mean volumetric breast density among the BI-RADS density categories. With increased BI-RADS density category, increase in mean volumetric breast density was also seen (P BI-RADS categories and volumetric density grading by fully automated software (ρ = 0.728, P BI-RADS density category by two observers showed fair agreement (κ = 0.398 and 0.388, respectively). In our study, a good correlation was seen between density grading using fully automated volumetric method and density grading using BI-RADS density categories assigned by the two radiologists. Thus, the fully automated volumetric method may be used to quantify breast density on routine mammography. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  7. The role of cone-beam breast-CT for breast cancer detection relative to breast density.

    Science.gov (United States)

    Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe

    2017-12-01

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, pdensity group (pdensity breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (pdensity types (pdensity types (p<0.001).

  8. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  9. Predicting axillary lymph node metastasis from kinetic statistics of DCE-MRI breast images

    Science.gov (United States)

    Ashraf, Ahmed B.; Lin, Lilie; Gavenonis, Sara C.; Mies, Carolyn; Xanthopoulos, Eric; Kontos, Despina

    2012-03-01

    The presence of axillary lymph node metastases is the most important prognostic factor in breast cancer and can influence the selection of adjuvant therapy, both chemotherapy and radiotherapy. In this work we present a set of kinetic statistics derived from DCE-MRI for predicting axillary node status. Breast DCE-MRI images from 69 women with known nodal status were analyzed retrospectively under HIPAA and IRB approval. Axillary lymph nodes were positive in 12 patients while 57 patients had no axillary lymph node involvement. Kinetic curves for each pixel were computed and a pixel-wise map of time-to-peak (TTP) was obtained. Pixels were first partitioned according to the similarity of their kinetic behavior, based on TTP values. For every kinetic curve, the following pixel-wise features were computed: peak enhancement (PE), wash-in-slope (WIS), wash-out-slope (WOS). Partition-wise statistics for every feature map were calculated, resulting in a total of 21 kinetic statistic features. ANOVA analysis was done to select features that differ significantly between node positive and node negative women. Using the computed kinetic statistic features a leave-one-out SVM classifier was learned that performs with AUC=0.77 under the ROC curve, outperforming the conventional kinetic measures, including maximum peak enhancement (MPE) and signal enhancement ratio (SER), (AUCs of 0.61 and 0.57 respectively). These findings suggest that our DCE-MRI kinetic statistic features can be used to improve the prediction of axillary node status in breast cancer patients. Such features could ultimately be used as imaging biomarkers to guide personalized treatment choices for women diagnosed with breast cancer.

  10. Annual Screening Mammogram and its Relation to Breast Density

    Directory of Open Access Journals (Sweden)

    Sabek EAS

    2017-11-01

    Full Text Available Background: Current national screening programs totally depend on mammographic evaluation. After increased incidence of breast cancer in women under the age of 35, mammography sensitivity in now a question. Several factors added to decrease sensitivity of mammography, such as increased density in older age groups and increased aggressiveness of tumour biology. All these factors will change the reliability of the screening program. The study is a retrospective study conducted at Ain Shams University. Method: 138 patients diagnosed with cancer breast underwent both mammography and sonography to determine percentage of patient with more than one focus, age and density distribution breast cancer in the affected patient and accuracy of both mammography and US. Results: By studying this population, we found that around 61,44% have areas of density ranging from dense breast, heterogenous density or scattered density. These areas of density render the mammography a less sensitive tool as its sensitivity fall to 34.09%, while that of US was 77.27%. Conclusion: As breast cancer is prevalent in younger population, also with increased density in older population who are relatively insensitive to mammography, we recommended the use of Automated Breast Ultrasound (ABUS in the national screening program.

  11. Tumor phenotype and breast density in distinct categories of interval cancer: results of population-based mammography screening in Spain.

    Science.gov (United States)

    Domingo, Laia; Salas, Dolores; Zubizarreta, Raquel; Baré, Marisa; Sarriugarte, Garbiñe; Barata, Teresa; Ibáñez, Josefa; Blanch, Jordi; Puig-Vives, Montserrat; Fernández, Ana; Castells, Xavier; Sala, Maria

    2014-01-10

    Interval cancers are tumors arising after a negative screening episode and before the next screening invitation. They can be classified into true interval cancers, false-negatives, minimal-sign cancers, and occult tumors based on mammographic findings in screening and diagnostic mammograms. This study aimed to describe tumor-related characteristics and the association of breast density and tumor phenotype within four interval cancer categories. We included 2,245 invasive tumors (1,297 screening-detected and 948 interval cancers) diagnosed from 2000 to 2009 among 645,764 women aged 45 to 69 who underwent biennial screening in Spain. Interval cancers were classified by a semi-informed retrospective review into true interval cancers (n = 455), false-negatives (n = 224), minimal-sign (n = 166), and occult tumors (n = 103). Breast density was evaluated using Boyd's scale and was conflated into: 75%. Tumor-related information was obtained from cancer registries and clinical records. Tumor phenotype was defined as follows: luminal A: ER+/HER2- or PR+/HER2-; luminal B: ER+/HER2+ or PR+/HER2+; HER2: ER-/PR-/HER2+; triple-negative: ER-/PR-/HER2-. The association of tumor phenotype and breast density was assessed using a multinomial logistic regression model. Adjusted odds ratios (OR) and 95% confidence intervals (95% CI) were calculated. All statistical tests were two-sided. Forty-eight percent of interval cancers were true interval cancers and 23.6% false-negatives. True interval cancers were associated with HER2 and triple-negative phenotypes (OR = 1.91 (95% CI:1.22-2.96), OR = 2.07 (95% CI:1.42-3.01), respectively) and extremely dense breasts (>75%) (OR = 1.67 (95% CI:1.08-2.56)). However, among true interval cancers a higher proportion of triple-negative tumors was observed in predominantly fatty breasts (breasts (28.7%, 21.4%, 11.3% and 14.3%, respectively; cancers, extreme breast density being strongly associated with occult tumors (OR

  12. Quantifying heterogeneity of lesion uptake in dynamic contrast enhanced MRI for breast cancer diagnosis

    International Nuclear Information System (INIS)

    Karahaliou, A; Skiadopoulos, S; Yiakoumelos, A; Costaridou, L; Vassiou, K; Kanavou, T

    2009-01-01

    The current study investigates whether texture features extracted from lesion kinetics feature maps can be used for breast cancer diagnosis. Fifty five women with 57 breast lesions (27 benign, 30 malignant) were subjected to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on 1.5T system. A linear-slope model was fitted pixel-wise to a representative lesion slice time series and fitted parameters were used to create three kinetic maps (wash out, time to peak enhancement and peak enhancement). 28 grey level co-occurrence matrices features were extracted from each lesion kinetic map. The ability of texture features per map in discriminating malignant from benign lesions was investigated using a Probabilistic Neural Network classifier. Additional classification was performed by combining classification outputs of most discriminating feature subsets from the three maps, via majority voting. The combined scheme outperformed classification based on individual maps achieving area under Receiver Operating Characteristics curve 0.960±0.029. Results suggest that heterogeneity of breast lesion kinetics, as quantified by texture analysis, may contribute to computer assisted tissue characterization in DCE-MRI.

  13. A study of usefulness for the plan based on only MRI using ViewRay MRIdian system

    International Nuclear Information System (INIS)

    Jeon, Chang Woo; Lee, Ho Jin; An, Beom Seok; Kim, Chan Young; Lee, Je Hee

    2015-01-01

    By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT and MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head and Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head and Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head and Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head and Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head and Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head and Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head and Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head and Neck

  14. A web-based personalized risk communication and decision-making tool for women with dense breasts: Design and methods of a randomized controlled trial within an integrated health care system.

    Science.gov (United States)

    Knerr, Sarah; Wernli, Karen J; Leppig, Kathleen; Ehrlich, Kelly; Graham, Amanda L; Farrell, David; Evans, Chalanda; Luta, George; Schwartz, Marc D; O'Neill, Suzanne C

    2017-05-01

    Mammographic breast density is one of the strongest risk factors for breast cancer after age and family history. Mandatory breast density disclosure policies are increasing nationally without clear guidance on how to communicate density status to women. Coupling density disclosure with personalized risk counseling and decision support through a web-based tool may be an effective way to allow women to make informed, values-consistent risk management decisions without increasing distress. This paper describes the design and methods of Engaged, a prospective, randomized controlled trial examining the effect of online personalized risk counseling and decision support on risk management decisions in women with dense breasts and increased breast cancer risk. The trial is embedded in a large integrated health care system in the Pacific Northwest. A total of 1250 female health plan members aged 40-69 with a recent negative screening mammogram who are at increased risk for interval cancer based on their 5-year breast cancer risk and BI-RADS® breast density will be randomly assigned to access either a personalized web-based counseling and decision support tool or standard educational content. Primary outcomes will be assessed using electronic health record data (i.e., chemoprevention and breast MRI utilization) and telephone surveys (i.e., distress) at baseline, six weeks, and twelve months. Engaged will provide evidence about whether a web-based personalized risk counseling and decision support tool is an effective method for communicating with women about breast density and risk management. An effective intervention could be disseminated with minimal clinical burden to align with density disclosure mandates. Clinical Trials Registration Number:NCT03029286. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Mammographic Breast Density and Breast Cancer Molecular Subtypes: The Kenyan-African Aspect

    Directory of Open Access Journals (Sweden)

    Asim Jamal Shaikh

    2018-01-01

    Full Text Available Introduction. Data examining mammographic breast density (MBD among patients in Sub-Saharan Africa are sparse. We evaluated how MBD relates to breast cancer characteristics in Kenyan women undergoing diagnostic mammography. Methods. This cross-sectional study included women with pathologically confirmed breast cancers (n=123. Pretreatment mammograms of the unaffected breast were assessed to estimate absolute dense area (cm2, nondense area (cm2, and percent density (PD. Relationships between density measurements and clinical characteristics were evaluated using analysis of covariance. Results. Median PD and dense area were 24.9% and 85.3 cm2. Higher PD and dense area were observed in younger women (P<0.01. Higher dense and nondense areas were observed in obese women (P-trend < 0.01. Estrogen receptor (ER positive patients (73% had higher PD and dense area than ER-negative patients (P≤0.02. Triple negative breast cancer (TNBC patients (17% had lower PD and dense area (P≤0.01 compared with non-TNBCs. No associations were observed between MBD and tumor size and grade. Conclusions. Our findings show discordant relationships between MBD and molecular tumor subtypes to those previously observed in Western populations. The relatively low breast density observed at diagnosis may have important implications for cancer prevention initiatives in Kenya. Subsequent larger studies are needed to confirm these findings.

  16. Values of kinetic features measured by computer-aided for breast MRI

    International Nuclear Information System (INIS)

    Zhang Lina; Zhao Zuowei; Song Qingwei; Wang Shaowu; Miao Yanwei

    2012-01-01

    Objective: To investigate the value of kinetic features measured by computer-aided diagnosis (CAD) for breast MRI. Methods: One hundred and sixty four lesions diagnosed pathologically by operation or biopsy comprised the analysis set. Automated lesion kinetic information from CADStream programs for breast MRI was identified. Three CAD variables were compared for benign and malignant lesions: initial phase peak enhancement (greatest percentage of signal intensity increase on first contrast enhanced sequence), delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement (washout, plateau, or persistent), and delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent). Morphological characteristics of breast lesions were described according to breast imaging and reporting data system (BI-RADS). Initial phase peak enhancement mean values between benign and malignant breast lesions were compared by using Wilcoxon rank-sum test, delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement or by single most suspicious type of kinetics between benign and malignant breast lesions were compared by using Chi-square test. Results: There were 72 benign and 92 malignant breast lesions. A total of 123 (75.0%) mass lesions were identified,and the other 41 (25.0%) lesions showed no mass. Thirty lesions were BI-RADS-MRI 2, 68 lesions were BI-RADS-MRI 3, 43 lesions were BI-RADS-MRI 4, 23 lesions were BI-RADS-MRI 5. Initial phase peak enhancement mean values of benign and malignant lesions were 237% (69% to 629%) and 336% (86% to 793%), respectively. There was no significant difference between benign and malignant lesions in initial peak enhancement mean value (Z=-1.626, P=0.104). Delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent) for

  17. Intratumor heterogeneity of DCE-MRI reveals Ki-67 proliferation status in breast cancer

    Science.gov (United States)

    Cheng, Hu; Fan, Ming; Zhang, Peng; Liu, Bin; Shao, Guoliang; Li, Lihua

    2018-03-01

    Breast cancer is a highly heterogeneous disease both biologically and clinically, and certain pathologic parameters, i.e., Ki67 expression, are useful in predicting the prognosis of patients. The aim of the study is to identify intratumor heterogeneity of breast cancer for predicting Ki-67 proliferation status in estrogen receptor (ER)-positive breast cancer patients. A dataset of 77 patients was collected who underwent dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) examination. Of these patients, 51 were high-Ki-67 expression and 26 were low-Ki-67 expression. We partitioned the breast tumor into subregions using two methods based on the values of time to peak (TTP) and peak enhancement rate (PER). Within each tumor subregion, image features were extracted including statistical and morphological features from DCE-MRI. The classification models were applied on each region separately to assess whether the classifiers based on features extracted from various subregions features could have different performance for prediction. An area under a receiver operating characteristic curve (AUC) was computed using leave-one-out cross-validation (LOOCV) method. The classifier using features related with moderate time to peak achieved best performance with AUC of 0.826 than that based on the other regions. While using multi-classifier fusion method, the AUC value was significantly (P=0.03) increased to 0.858+/-0.032 compare to classifier with AUC of 0.778 using features from the entire tumor. The results demonstrated that features reflect heterogeneity in intratumoral subregions can improve the classifier performance to predict the Ki-67 proliferation status than the classifier using features from entire tumor alone.

  18. Implementation of several mathematical algorithms to breast tissue density classification

    Science.gov (United States)

    Quintana, C.; Redondo, M.; Tirao, G.

    2014-02-01

    The accuracy of mammographic abnormality detection methods is strongly dependent on breast tissue characteristics, where a dense breast tissue can hide lesions causing cancer to be detected at later stages. In addition, breast tissue density is widely accepted to be an important risk indicator for the development of breast cancer. This paper presents the implementation and the performance of different mathematical algorithms designed to standardize the categorization of mammographic images, according to the American College of Radiology classifications. These mathematical techniques are based on intrinsic properties calculations and on comparison with an ideal homogeneous image (joint entropy, mutual information, normalized cross correlation and index Q) as categorization parameters. The algorithms evaluation was performed on 100 cases of the mammographic data sets provided by the Ministerio de Salud de la Provincia de Córdoba, Argentina—Programa de Prevención del Cáncer de Mama (Department of Public Health, Córdoba, Argentina, Breast Cancer Prevention Program). The obtained breast classifications were compared with the expert medical diagnostics, showing a good performance. The implemented algorithms revealed a high potentiality to classify breasts into tissue density categories.

  19. Computer-aided assessment of breast density: comparison of supervised deep learning and feature-based statistical learning.

    Science.gov (United States)

    Li, Songfeng; Wei, Jun; Chan, Heang-Ping; Helvie, Mark A; Roubidoux, Marilyn A; Lu, Yao; Zhou, Chuan; Hadjiiski, Lubomir M; Samala, Ravi K

    2018-01-09

    Breast density is one of the most significant factors that is associated with cancer risk. In this study, our purpose was to develop a supervised deep learning approach for automated estimation of percentage density (PD) on digital mammograms (DMs). The input 'for processing' DMs was first log-transformed, enhanced by a multi-resolution preprocessing scheme, and subsampled to a pixel size of 800 µm  ×  800 µm from 100 µm  ×  100 µm. A deep convolutional neural network (DCNN) was trained to estimate a probability map of breast density (PMD) by using a domain adaptation resampling method. The PD was estimated as the ratio of the dense area to the breast area based on the PMD. The DCNN approach was compared to a feature-based statistical learning approach. Gray level, texture and morphological features were extracted and a least absolute shrinkage and selection operator was used to combine the features into a feature-based PMD. With approval of the Institutional Review Board, we retrospectively collected a training set of 478 DMs and an independent test set of 183 DMs from patient files in our institution. Two experienced mammography quality standards act radiologists interactively segmented PD as the reference standard. Ten-fold cross-validation was used for model selection and evaluation with the training set. With cross-validation, DCNN obtained a Dice's coefficient (DC) of 0.79  ±  0.13 and Pearson's correlation (r) of 0.97, whereas feature-based learning obtained DC  =  0.72  ±  0.18 and r  =  0.85. For the independent test set, DCNN achieved DC  =  0.76  ±  0.09 and r  =  0.94, while feature-based learning achieved DC  =  0.62  ±  0.21 and r  =  0.75. Our DCNN approach was significantly better and more robust than the feature-based learning approach for automated PD estimation on DMs, demonstrating its potential use for automated density reporting as well as

  20. Computer-aided assessment of breast density: comparison of supervised deep learning and feature-based statistical learning

    Science.gov (United States)

    Li, Songfeng; Wei, Jun; Chan, Heang-Ping; Helvie, Mark A.; Roubidoux, Marilyn A.; Lu, Yao; Zhou, Chuan; Hadjiiski, Lubomir M.; Samala, Ravi K.

    2018-01-01

    Breast density is one of the most significant factors that is associated with cancer risk. In this study, our purpose was to develop a supervised deep learning approach for automated estimation of percentage density (PD) on digital mammograms (DMs). The input ‘for processing’ DMs was first log-transformed, enhanced by a multi-resolution preprocessing scheme, and subsampled to a pixel size of 800 µm  ×  800 µm from 100 µm  ×  100 µm. A deep convolutional neural network (DCNN) was trained to estimate a probability map of breast density (PMD) by using a domain adaptation resampling method. The PD was estimated as the ratio of the dense area to the breast area based on the PMD. The DCNN approach was compared to a feature-based statistical learning approach. Gray level, texture and morphological features were extracted and a least absolute shrinkage and selection operator was used to combine the features into a feature-based PMD. With approval of the Institutional Review Board, we retrospectively collected a training set of 478 DMs and an independent test set of 183 DMs from patient files in our institution. Two experienced mammography quality standards act radiologists interactively segmented PD as the reference standard. Ten-fold cross-validation was used for model selection and evaluation with the training set. With cross-validation, DCNN obtained a Dice’s coefficient (DC) of 0.79  ±  0.13 and Pearson’s correlation (r) of 0.97, whereas feature-based learning obtained DC  =  0.72  ±  0.18 and r  =  0.85. For the independent test set, DCNN achieved DC  =  0.76  ±  0.09 and r  =  0.94, while feature-based learning achieved DC  =  0.62  ±  0.21 and r  =  0.75. Our DCNN approach was significantly better and more robust than the feature-based learning approach for automated PD estimation on DMs, demonstrating its potential use for automated density reporting as

  1. Textural kinetics: a novel dynamic contrast-enhanced (DCE)-MRI feature for breast lesion classification.

    Science.gov (United States)

    Agner, Shannon C; Soman, Salil; Libfeld, Edward; McDonald, Margie; Thomas, Kathleen; Englander, Sarah; Rosen, Mark A; Chin, Deanna; Nosher, John; Madabhushi, Anant

    2011-06-01

    Dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) of the breast has emerged as an adjunct imaging tool to conventional X-ray mammography due to its high detection sensitivity. Despite the increasing use of breast DCE-MRI, specificity in distinguishing malignant from benign breast lesions is low, and interobserver variability in lesion classification is high. The novel contribution of this paper is in the definition of a new DCE-MRI descriptor that we call textural kinetics, which attempts to capture spatiotemporal changes in breast lesion texture in order to distinguish malignant from benign lesions. We qualitatively and quantitatively demonstrated on 41 breast DCE-MRI studies that textural kinetic features outperform signal intensity kinetics and lesion morphology features in distinguishing benign from malignant lesions. A probabilistic boosting tree (PBT) classifier in conjunction with textural kinetic descriptors yielded an accuracy of 90%, sensitivity of 95%, specificity of 82%, and an area under the curve (AUC) of 0.92. Graph embedding, used for qualitative visualization of a low-dimensional representation of the data, showed the best separation between benign and malignant lesions when using textural kinetic features. The PBT classifier results and trends were also corroborated via a support vector machine classifier which showed that textural kinetic features outperformed the morphological, static texture, and signal intensity kinetics descriptors. When textural kinetic attributes were combined with morphologic descriptors, the resulting PBT classifier yielded 89% accuracy, 99% sensitivity, 76% specificity, and an AUC of 0.91.

  2. Radiographic evaluation of vessel count and density with quantitative magnetic resonance imaging during external breast expansion in Asian women: A prospective clinical trial.

    Science.gov (United States)

    Myung, Yujin; Kwon, Heeyeon; Pak, Changsik; Lee, Hobin; Jeong, Jae Hoon; Heo, Chan Yeong

    2016-12-01

    Breast augmentation with fat transfer does not bear the risks associated with silicone implantation. The method can potentially be especially useful in Asian women, who often reject augmentation mammoplasty with implants. This prospective clinical trial evaluated the effects of external breast expansion on breast density and vessel count using magnetic resonance imaging. Thirty-four enrolled patients were instructed to apply one of two devices, the conventional BRAVA device (used in the AESTES trial) or a novel external expansion device (EVERA) designed for Asian women, continuously for 8 h per day for 12 weeks. For external expansion, the pressure was set to 25 mmHg. Follow-up examinations were performed for 4 weeks after completion of the expansion. The ratio between the fibroglandular and adipose tissues of the breast was measured using T1-weighted MRI, and the number of vessels in the breast tissue was determined before and after the treatment by contrast MRI. Additionally, the volume of the breast was measured by laser scanning before, during, and after the device application. The obtained measurements were compared within and between the groups at different time points. Six patients dropped out, while 28 completed the trial without major side effects or adverse events. External expansion significantly increased breast vessel count in both the EVERA and AESTES groups (p = 0.019, p = 0.022). However, it did not significantly change breast density in either group (p = 0.186, p = 0.638). No significant intergroup differences were noted in vessel count (p = 0.874) or density (p = 0.482). Breast volume increases after 12 weeks of application were statistically significant in both groups, with mean changes of 81 ± 22 cc (AESTES) and 98 ± 30 cc (EVERA) (p Asian women. Level II, therapeutic study. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  4. Software Toolbox for Low-Frequency Conductivity and Current Density Imaging Using MRI.

    Science.gov (United States)

    Sajib, Saurav Z K; Katoch, Nitish; Kim, Hyung Joong; Kwon, Oh In; Woo, Eung Je

    2017-11-01

    Low-frequency conductivity and current density imaging using MRI includes magnetic resonance electrical impedance tomography (MREIT), diffusion tensor MREIT (DT-MREIT), conductivity tensor imaging (CTI), and magnetic resonance current density imaging (MRCDI). MRCDI and MREIT provide current density and isotropic conductivity images, respectively, using current-injection phase MRI techniques. DT-MREIT produces anisotropic conductivity tensor images by incorporating diffusion weighted MRI into MREIT. These current-injection techniques are finding clinical applications in diagnostic imaging and also in transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), and electroporation where treatment currents can function as imaging currents. To avoid adverse effects of nerve and muscle stimulations due to injected currents, conductivity tensor imaging (CTI) utilizes B1 mapping and multi-b diffusion weighted MRI to produce low-frequency anisotropic conductivity tensor images without injecting current. This paper describes numerical implementations of several key mathematical functions for conductivity and current density image reconstructions in MRCDI, MREIT, DT-MREIT, and CTI. To facilitate experimental studies of clinical applications, we developed a software toolbox for these low-frequency conductivity and current density imaging methods. This MR-based conductivity imaging (MRCI) toolbox includes 11 toolbox functions which can be used in the MATLAB environment. The MRCI toolbox is available at http://iirc.khu.ac.kr/software.html . Its functions were tested by using several experimental datasets, which are provided together with the toolbox. Users of the toolbox can focus on experimental designs and interpretations of reconstructed images instead of developing their own image reconstruction softwares. We expect more toolbox functions to be added from future research outcomes. Low-frequency conductivity and current density imaging using MRI includes

  5. Breast Density and Benign Breast Disease: Risk Assessment to Identify Women at High Risk of Breast Cancer.

    Science.gov (United States)

    Tice, Jeffrey A; Miglioretti, Diana L; Li, Chin-Shang; Vachon, Celine M; Gard, Charlotte C; Kerlikowske, Karla

    2015-10-01

    Women with proliferative breast lesions are candidates for primary prevention, but few risk models incorporate benign findings to assess breast cancer risk. We incorporated benign breast disease (BBD) diagnoses into the Breast Cancer Surveillance Consortium (BCSC) risk model, the only breast cancer risk assessment tool that uses breast density. We developed and validated a competing-risk model using 2000 to 2010 SEER data for breast cancer incidence and 2010 vital statistics to adjust for the competing risk of death. We used Cox proportional hazards regression to estimate the relative hazards for age, race/ethnicity, family history of breast cancer, history of breast biopsy, BBD diagnoses, and breast density in the BCSC. We included 1,135,977 women age 35 to 74 years undergoing mammography with no history of breast cancer; 17% of the women had a prior breast biopsy. During a mean follow-up of 6.9 years, 17,908 women were diagnosed with invasive breast cancer. The BCSC BBD model slightly overpredicted risk (expected-to-observed ratio, 1.04; 95% CI, 1.03 to 1.06) and had modest discriminatory accuracy (area under the receiver operator characteristic curve, 0.665). Among women with proliferative findings, adding BBD to the model increased the proportion of women with an estimated 5-year risk of 3% or higher from 9.3% to 27.8% (P<.001). The BCSC BBD model accurately estimates women's risk for breast cancer using breast density and BBD diagnoses. Greater numbers of high-risk women eligible for primary prevention after BBD diagnosis are identified using the BCSC BBD model. © 2015 by American Society of Clinical Oncology.

  6. Imaging diagnosis of breast tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyeong Cheol; Oh, Ki Keun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To evaluate the radiologic findings of breast tuberculosis. The authors evaluated the radiologic findings of five cases of surgically confirmed tuberculosis of the breast. Patients were examined with mammography (n=5), ultrasonography (n=3), and MRI (n=2). All patients were female. Four patients had unilateral lesion and the remaining one patient had bilateral breast tuberculosis. Mammographic findings were mainly radiopaque mass density without secondary signs. Two patients showed secondary signs such as skin thickening, parenchymal distortion, and nipple retraction. Ultrasonographic findings were variable but helpful in differentiating benign from malignant breast lesion, MRI findings were more helpful in differentiating abscess from malignant lesions. Radiologic findings were useful to diagnose tuberculosis of the breast, but fine needle aspiration biopsy and culture were needed for suspicious radiologic findings.

  7. Imaging diagnosis of breast tuberculosis

    International Nuclear Information System (INIS)

    Shin, Hyeong Cheol; Oh, Ki Keun

    1994-01-01

    To evaluate the radiologic findings of breast tuberculosis. The authors evaluated the radiologic findings of five cases of surgically confirmed tuberculosis of the breast. Patients were examined with mammography (n=5), ultrasonography (n=3), and MRI (n=2). All patients were female. Four patients had unilateral lesion and the remaining one patient had bilateral breast tuberculosis. Mammographic findings were mainly radiopaque mass density without secondary signs. Two patients showed secondary signs such as skin thickening, parenchymal distortion, and nipple retraction. Ultrasonographic findings were variable but helpful in differentiating benign from malignant breast lesion, MRI findings were more helpful in differentiating abscess from malignant lesions. Radiologic findings were useful to diagnose tuberculosis of the breast, but fine needle aspiration biopsy and culture were needed for suspicious radiologic findings

  8. Mammographic breast density as a risk factor for breast cancer: awareness in a recently screened clinical sample.

    Science.gov (United States)

    O'Neill, Suzanne C; Leventhal, Kara Grace; Scarles, Marie; Evans, Chalanda N; Makariou, Erini; Pien, Edward; Willey, Shawna

    2014-01-01

    Breast density is an established, independent risk factor for breast cancer. Despite this, density has not been included in standard risk models or routinely disclosed to patients. However, this is changing in the face of legal mandates and advocacy efforts. Little information exists regarding women's awareness of density as a risk factor, their personal risk, and risk management options. We assessed awareness of density as a risk factor and whether sociodemographic variables, breast cancer risk factors. and perceived breast cancer risk were associated with awareness in 344 women with a recent screening mammogram at a tertiary care center. Overall, 62% of women had heard about density as a risk factor and 33% had spoken to a provider about breast density. Of the sample, 18% reported that their provider indicated that they had high breast density. Awareness of density as a risk factor was greater among White women and those with other breast cancer risk factors. Our results suggest that although a growing number of women are aware of breast density as a risk factor, this awareness varies. Growing mandates for disclosure suggest the need for patient education interventions for women at increased risk for the disease and to ensure all women are equally aware of their risks. Copyright © 2014 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  9. Local breast density assessment using reacquired mammographic images.

    Science.gov (United States)

    García, Eloy; Diaz, Oliver; Martí, Robert; Diez, Yago; Gubern-Mérida, Albert; Sentís, Melcior; Martí, Joan; Oliver, Arnau

    2017-08-01

    The aim of this paper is to evaluate the spatial glandular volumetric tissue distribution as well as the density measures provided by Volpara™ using a dataset composed of repeated pairs of mammograms, where each pair was acquired in a short time frame and in a slightly changed position of the breast. We conducted a retrospective analysis of 99 pairs of repeatedly acquired full-field digital mammograms from 99 different patients. The commercial software Volpara™ Density Maps (Volpara Solutions, Wellington, New Zealand) is used to estimate both the global and the local glandular tissue distribution in each image. The global measures provided by Volpara™, such as breast volume, volume of glandular tissue, and volumetric breast density are compared between the two acquisitions. The evaluation of the local glandular information is performed using histogram similarity metrics, such as intersection and correlation, and local measures, such as statistics from the difference image and local gradient correlation measures. Global measures showed a high correlation (breast volume R=0.99, volume of glandular tissue R=0.94, and volumetric breast density R=0.96) regardless the anode/filter material. Similarly, histogram intersection and correlation metric showed that, for each pair, the images share a high degree of information. Regarding the local distribution of glandular tissue, small changes in the angle of view do not yield significant differences in the glandular pattern, whilst changes in the breast thickness between both acquisition affect the spatial parenchymal distribution. This study indicates that Volpara™ Density Maps is reliable in estimating the local glandular tissue distribution and can be used for its assessment and follow-up. Volpara™ Density Maps is robust to small variations of the acquisition angle and to the beam energy, although divergences arise due to different breast compression conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Breast Dynamic Contrast Enhanced MRI: Fibrocystic Changes Presenting as a Non-mass Enhancement Mimicking Malignancy.

    Science.gov (United States)

    Milosevic, Zorica C; Nadrljanski, Mirjan M; Milovanovic, Zorka M; Gusic, Nina Z; Vucicevic, Slavko S; Radulovic, Olga S

    2017-06-01

    We aimed to analyse the morphokinetic features of breast fibrocystic changes (nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia) presenting as a non-mass enhancement (NME)in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) examination. Forty-six patients with histologically proven fibrocystic changes (FCCs) were retrospectively reviewed, according to Breast Imaging Reporting and Data System (BI-RADS) lexicon. Prior to DCE-MRI examination, a unilateral breast lesion suspicious of malignancy was detected clinically, on mammography or breast ultrasonography. The predominant features of FCCs presenting as NME in DCE-MRI examination were: unilateral regional or diffuse distribution (in 35 patients or 76.1%), heterogeneous or clumped internal pattern of enhancement (in 36 patients or 78.3%), plateau time-intensity curve (in 25 patients or 54.3%), moderate or fast wash-in (in 31 patients or 67.4%).Nonproliferative lesions were found in 11 patients (24%), proliferative lesions without atypia in 29 patients (63%) and lesions with atypia in six patients (13%), without statistically significant difference of morphokinetic features, except of the association of clustered microcysts with proliferative dysplasia without atypia. FCCs presenting as NME in DCE-MRI examination have several morphokinetic features suspicious of malignancy, therefore requiring biopsy (BI-RADS 4). Nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia predominantly share the same predefined DCE-MRI morphokinetic features.

  11. Tumor phenotype and breast density in distinct categories of interval cancer: results of population-based mammography screening in Spain

    Science.gov (United States)

    2014-01-01

    Introduction Interval cancers are tumors arising after a negative screening episode and before the next screening invitation. They can be classified into true interval cancers, false-negatives, minimal-sign cancers, and occult tumors based on mammographic findings in screening and diagnostic mammograms. This study aimed to describe tumor-related characteristics and the association of breast density and tumor phenotype within four interval cancer categories. Methods We included 2,245 invasive tumors (1,297 screening-detected and 948 interval cancers) diagnosed from 2000 to 2009 among 645,764 women aged 45 to 69 who underwent biennial screening in Spain. Interval cancers were classified by a semi-informed retrospective review into true interval cancers (n = 455), false-negatives (n = 224), minimal-sign (n = 166), and occult tumors (n = 103). Breast density was evaluated using Boyd’s scale and was conflated into: 75%. Tumor-related information was obtained from cancer registries and clinical records. Tumor phenotype was defined as follows: luminal A: ER+/HER2- or PR+/HER2-; luminal B: ER+/HER2+ or PR+/HER2+; HER2: ER-/PR-/HER2+; triple-negative: ER-/PR-/HER2-. The association of tumor phenotype and breast density was assessed using a multinomial logistic regression model. Adjusted odds ratios (OR) and 95% confidence intervals (95% CI) were calculated. All statistical tests were two-sided. Results Forty-eight percent of interval cancers were true interval cancers and 23.6% false-negatives. True interval cancers were associated with HER2 and triple-negative phenotypes (OR = 1.91 (95% CI:1.22-2.96), OR = 2.07 (95% CI:1.42-3.01), respectively) and extremely dense breasts (>75%) (OR = 1.67 (95% CI:1.08-2.56)). However, among true interval cancers a higher proportion of triple-negative tumors was observed in predominantly fatty breasts (breasts (28.7%, 21.4%, 11.3% and 14.3%, respectively; screening-detected cancers, extreme breast density

  12. Comparison of Breast Density Between Synthesized Versus Standard Digital Mammography.

    Science.gov (United States)

    Haider, Irfanullah; Morgan, Matthew; McGow, Anna; Stein, Matthew; Rezvani, Maryam; Freer, Phoebe; Hu, Nan; Fajardo, Laurie; Winkler, Nicole

    2018-06-12

    To evaluate perceptual difference in breast density classification using synthesized mammography (SM) compared with standard or full-field digital mammography (FFDM) for screening. This institutional review board-approved, retrospective, multireader study evaluated breast density on 200 patients who underwent baseline screening mammogram during which both SM and FFDM were obtained contemporaneously from June 1, 2016, through November 30, 2016. Qualitative breast density was independently assigned by seven readers initially evaluating FFDM alone. Then, in a separate session, these same readers assigned breast density using synthetic views alone on the same 200 patients. The readers were again blinded to each other's assignment. Qualitative density assessment was based on BI-RADS fifth edition. Interreader agreement was evaluated with κ statistic using 95% confidence intervals. Testing for homogeneity in paired proportions was performed using McNemar's test with a level of significance of .05. For patients across the SM and standard 2-D data set, diagnostic testing with McNemar's test with P = 0.32 demonstrates that the minimal density transitions across FFDM and SM are not statistically significant density shifts. Taking clinical significance into account, only 8 of 200 (4%) patients had clinically significant transition (dense versus not dense). There was substantial interreader agreement with overall κ in FFDM of 0.71 (minimum 0.53, maximum 0.81) and overall SM κ average of 0.63 (minimum 0.56, maximum 0.87). Overall subjective breast density assignment by radiologists on SM is similar to density assignment on standard 2-D mammogram. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  14. The association of breast density with breast cancer mortality in African American and white women screened in community practice.

    Science.gov (United States)

    Zhang, Shengfan; Ivy, Julie S; Diehl, Kathleen M; Yankaskas, Bonnie C

    2013-01-01

    The effect of breast density on survival outcomes for American women who participate in screening remains unknown. We studied the role of breast density on both breast cancer and other cause of mortality in screened women. Data for women with breast cancer, identified from the community-based Carolina Mammography Registry, were linked with the North Carolina cancer registry and NC death tapes for this study. Cause-specific Cox proportional hazards models were developed to analyze the effect of several covariates on breast cancer mortality-namely, age, race (African American/White), cancer stage at diagnosis (in situ, local, regional, and distant), and breast density (BI-RADS( ® ) 1-4). Two stratified Cox models were considered controlling for (1) age and race, and (2) age and cancer stage, respectively, to further study the effect of density. The cumulative incidence function with confidence interval approximation was used to quantify mortality probabilities over time. For this study, 22,597 screened women were identified as having breast cancer. The non-stratified and stratified Cox models showed no significant statistical difference in mortality between dense tissue and fatty tissue, while controlling for other covariate effects (p value = 0.1242, 0.0717, and 0.0619 for the non-stratified, race-stratified, and cancer stage-stratified models, respectively). The cumulative mortality probability estimates showed that women with dense breast tissues did not have significantly different breast cancer mortality than women with fatty breast tissue, regardless of age (e.g., 10-year confidence interval of mortality probabilities for whites aged 60-69 white: 0.056-0.090 vs. 0.054-0.083). Aging, African American race, and advanced cancer stage were found to be significant risk factors for breast cancer mortality (hazard ratio >1.0). After controlling for cancer incidence, there was not a significant association between mammographic breast density and mortality, adjusting

  15. Comparative study of diffusion weighted imaging and dynamic contrast enhanced MRI for the detection of small breast cancers

    International Nuclear Information System (INIS)

    Tang Jianhua; Yan Fuhua; Zhou Meiling; Ye Fang; Xu Pengju

    2008-01-01

    Objective: To compare the sensitivity of diffusion weighted imaging (DWI) with dynamic contrast enhanced (DCE) MRI for the detection of small breast cancers and to evaluate the clinical value of DWI. Methods: Forty-eight patients with benign (n=25) and malignant (n=45) small breast lesions (≤2 cm) proved by pathology underwent DWI and DCE MRI. The DCE MRI was performed using FLASH sequence and the time-signal intensity curve was drawn. The DWI was performed using GRAPPA- EPI sequence with different b values (800, 1000 s/mm 2 ) and the ADC values of lesions were measured. The sensitivity and specificity of DWI for the detection of small breast cancers were compared with DCE MRI. Results: Forty of 45 small breast cancers and 19 of 25 small benign breast lesions were correctly diagnosed using DCE MRI. The sensitivity and positive predictive value of TIC were 88.9% (40/45) and 87.0% (40/46). With b values of 800 s/mm 2 and 1000 s/mm 2 , the average ADC values of small breast cancers were (1.153±0.192) x 10 -3 and (1.079±0.186) x 10 -3 mm 2 /s, while those of benign ones were (1.473±0.252) x 10 -3 and (1.419 ± 0.255) x 10 -3 mm 2 /s, respectively. There was no significant difference for the ADC values with different b values in the same group (P>0.05), while there was a significant difference between the malignant and the benign lesions (P 2 . Both the sensitivity and positive predictive value of diagnosis were 86.7% (39/45). The abilities of DWI and DCE MRI for the diagnosis of small breast cancers were the same. The sensitivity (93.3%) and positive predictive value (91.3%) were improved with the combination of DCE MRI and DWI. Conclusion: DWI has a high sensitivity for the detection of small breast cancers, the ADC value can provide valuable information in the differential diagnosis. (authors)

  16. SU-F-J-162: Is Bulky Electron Density Assignment Appropriatefor MRI-Only Based Treatment Planning for Lung Cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Prior, P; Chen, X; Johnstone, C; Gore, E; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: To assess the appropriateness of bulky electron density assisment for MRI-only treatment planning for lung cancer via comparing dosimetric difference between MRI- and CT-based plans. Methods: Planning 4DCTs acquired for six representative lung cancer patients were used to generate CT-based IMRT plans. To avoid the effect of anatomic difference between CT and MRI, MRI-based plans were generated using CTs by forcing the relative electron density (rED) of organ specific values from ICRU report 46 and using the mean rED value of the internal target volume (ITV) of the patient for the ITV. Both CT and “MRI” plans were generated using a research planning system (Monaco, Elekta) employing Monte Carlo dose calculation the following dose-volume-parameters (DVPs): D99 – dose delivered to 99% of the ITV/PTV volume; D95; D5; D1; Vpd –volume receiving the prescription dose; V5 – volume of normal lung irradiated > 5 Gy; and V20. The percent point difference and dose difference was used for comparison for Vpd-V5-V20 and D99-D1, respectively. Four additional plans per patient were calculated with rEDITV = 0.6 and 1.0 and rEDlung = 0.1 and 0.5. Results: Noticeable differences in the ITV and PTV point doses and DVPs were observed. Variations in Vpd ranged from 0.0–6.4% and 0.32–18.3% for the ITV and PTV, respectively. The ITV and PTV variations in D99, D95, D5 and D1 were 0.15–3.2 Gy. The normal lung V5 & V20 variations were no larger than 1.9%. In some instances, varying the rEDITV between rEDmean, 0.6 and 1.0 resulted in D95 increases ranging from 3.9–6.3%. Uniform rED assignment on normal lung affected DVPs of ITV and PTV by 4.0–9.8% and 0.3–19.6%, respectively. Conclusion: The commonly-used uniform rED assignment in MRI-only based planning may not be appropriate for lung-cancer. A voxel based method, e.g. synthetic CT generated from MRI data, is required. This work was partially funded by Elekta, Inc.

  17. Evaluation of Quantra Hologic Volumetric Computerized Breast Density Software in Comparison With Manual Interpretation in a Diverse Population.

    Science.gov (United States)

    Richard-Davis, Gloria; Whittemore, Brianna; Disher, Anthony; Rice, Valerie Montgomery; Lenin, Rathinasamy B; Dollins, Camille; Siegel, Eric R; Eswaran, Hari

    2018-01-01

    Increased mammographic breast density is a well-established risk factor for breast cancer development, regardless of age or ethnic background. The current gold standard for categorizing breast density consists of a radiologist estimation of percent density according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) criteria. This study compares paired qualitative interpretations of breast density on digital mammograms with quantitative measurement of density using Hologic's Food and Drug Administration-approved R2 Quantra volumetric breast density assessment tool. Our goal was to find the best cutoff value of Quantra-calculated breast density for stratifying patients accurately into high-risk and low-risk breast density categories. Screening digital mammograms from 385 subjects, aged 18 to 64 years, were evaluated. These mammograms were interpreted by a radiologist using the ACR's BI-RADS density method, and had quantitative density measured using the R2 Quantra breast density assessment tool. The appropriate cutoff for breast density-based risk stratification using Quantra software was calculated using manually determined BI-RADS scores as a gold standard, in which scores of D3/D4 denoted high-risk densities and D1/D2 denoted low-risk densities. The best cutoff value for risk stratification using Quantra-calculated breast density was found to be 14.0%, yielding a sensitivity of 65%, specificity of 77%, and positive and negative predictive values of 75% and 69%, respectively. Under bootstrap analysis, the best cutoff value had a mean ± SD of 13.70% ± 0.89%. Our study is the first to publish on a North American population that assesses the accuracy of the R2 Quantra system at breast density stratification. Quantitative breast density measures will improve accuracy and reliability of density determination, assisting future researchers to accurately calculate breast cancer risks associated with density increase.

  18. MRI-based volumetric assessment of cardiac anatomy and dose reduction via active breathing control during irradiation for left-sided breast cancer

    International Nuclear Information System (INIS)

    Krauss, Daniel J.; Kestin, Larry L.; Raff, Gilbert; Yan Di; Wong, John; Gentry, Ralph; Letts, Nicola; Vargas, Carlos E.; Martinez, Alvaro A.; Vicini, Frank A.

    2005-01-01

    Purpose: Heart dose-volume analysis using computed tomography (CT) is limited because of motion artifact and poor delineation between myocardium and ventricular space. We used dedicated cardiac magnetic resonance imaging (MRI) to quantify exclusion of left ventricular (LV) myocardium via active breathing control (ABC) during left breast irradiation and to determine the correlation between irradiated whole heart and LV volumes. Methods and materials: Fifteen patients who completed adjuvant irradiation for early-stage left breast cancer participated. Treatment consisted of 45 Gy to the entire breast using ABC followed by a 16-Gy electron boost to the lumpectomy cavity. Patients underwent planning CT scans in free breathing (FB) and moderate deep inspiration breath hold (mDIBH). Electrocardiogram-gated cardiac MRI was performed in the treatment position using α-cradle immobilization. MRI scans were acquired in late diastole (LD), mid-diastole (MD), and systole (S) for both FB and mDIBH. After image fusion with the patients' radiation therapy planning CT scan, MRI LV volumes were defined for the three examined phases of the cardiac cycle, and comparative dose-volume analysis was performed. Results: Cardiac volume definition was found to differ significantly because of combinations of respiratory and intrinsic heart motion. The fraction of LV myocardium receiving 50% (22.5 Gy) of the prescribed whole breast dose (V 22.5 ) was reduced by 85.3%, 91.8%, and 94.6% via ABC for LD, MD, and S, respectively. Linear regression revealed strong correlation between MRI-defined whole heart and LV V 22.5 reduction via ABC, suggesting that LV myocardium accounts for up to approximately 50% of the excluded heart volume through this technique. Significant but weaker correlations were noted between CT-defined whole heart and LV V 22.5 reductions with marked variability in the measurements of patients with larger amounts of heart in the treatment field. Conclusions: Cardiac MRI

  19. SU-D-207B-04: Morphological Features of MRI as a Correlate of Capsular Contracture in Breast Cancer Patients with Implant-Based Reconstructions

    International Nuclear Information System (INIS)

    Tyagi, N; Sutton, E; Hunt, M; Apte, A; Zhang, J; Oh, J; Mechalakos, J; Mehrara, B; Matros, E; Ho, A

    2016-01-01

    Purpose: Capsular contracture (CC) is a serious complication in patients receiving implant-based reconstruction for breast cancer. The goal of this study was to identify image-based correlates of CC using MRI imaging in breast cancer patients who received both MRI and clinical evaluation following reconstructive surgery. Methods: We analyzed a retrospective dataset of 50 patients who had both a diagnostic MR and a plastic surgeon’s evaluations of CC score (Baker’s score) within a six month period following mastectomy and reconstructive surgery. T2w sagittal MRIs (TR/TE = 3500/102 ms, slice thickness = 4 mm) were used for morphological shape features (roundness, eccentricity, solidity, extent and ratio-length) and histogram features (median, skewness and kurtosis) of the implant and the pectoralis muscle overlying the implant. Implant and pectoralis muscles were segmented in 3D using Computation Environment for Radiological Research (CERR) and shape and histogram features were calculated as a function of Baker’s score. Results: Shape features such as roundness and eccentricity were statistically significant in differentiating grade 1 and grade 2 (p = 0.009; p = 0.06) as well as grade 1 and grade 3 CC (p = 0.001; p = 0.006). Solidity and extent were statistically significant in differentiating grade 1 and grade 3 CC (p = 0.04; p = 0.04). Ratio-length was statistically significant in differentiating all grades of CC except grade 2 and grade 3 that showed borderline significance (p = 0.06). The muscle thickness, median intensity and kurtosis were significant in differentiating between grade 1 and grade 3 (p = 0.02), grade 1 and grade 2 (p = 0.03) and grade 1 and grade 3 (p = 0.01) respectively. Conclusion: Morphological shape features described on MR images were associated with the severity of CC. MRI may be important in objectively evaluating outcomes in breast cancer patients who undergo implant reconstruction.

  20. MRI features of intraductal papilloma of the breast: sheep in wolf's clothing?

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, Kathinka D; Roy, Sumit (Dept. of Radiology, Stavanger Univ. Hospital, Stavanger (Norway)), e-mail: kurk@sus.no; Saleh, Andreas (Inst. of Diagnostic Radiology, Duesseldorf Univ. Hospital, Duesseldorf (Germany)); Diallo-Danebrock, Raihana (Inst. of Pathology, Duesseldorf Univ. Hospital, Duesseldorf (Germany)); Skaane, Per (Dept. of Radiology, Ullevaal Univ. Hospital, Univ. of Oslo, Oslo (Norway))

    2011-04-15

    Background: Intraductal papillomas often present as small, smooth masses, dilated ducts or microcalcifications at mammography and as smooth, hypoechoic masses at sonography. At magnetic resonance imaging (MRI), intraductal papillomas often present as small smooth masses, however, often with strong enhancement with type 2 or 3 time intensity curves. The result of the MR analysis is therefore not infrequently inconclusive in order to characterize the mass as benign or malignant. Purpose: To characterize the appearance of intraductal papillomas of the breast at MRI, and determine whether the application of diagnostic rules described in literature could contribute to correctly classifying the lesions as benign. Material and Methods: Twenty patients with histologically proven intraductal papillomas were included. Two radiologists independently reviewed the MR images of the breast. The BI-RADS nomenclature was used to describe morphology and contrast-enhancement kinetics. Interobserver agreement in the interpretation of the MR images by the two investigators was performed. Kappa coefficient was calculated as index for the level of agreement. Subsequently, three sets of diagnostic rules, including the Goettinger score described by Fischer and the interpretation flowcharts according to Kinkel and to Tozaki were applied to characterize whether a biopsy should be recommended or not. Results: All papillomas presented as masses on dynamic contrast-enhanced MRI. Only five papillomas showed a round, oval, or lobulated shape combined with smooth margins and continuous rise of the time intensity curve. Using the Goettinger score, biopsy would be recommended in 16 patients. Based on the interpretation flowcharts of Kinkel and of Tozaki, an additional 13 and 10 papillomas, respectively, were correctly classified as benign. Dilated ducts were visible in 10 patients. The interobserver agreement was good or excellent for all included variables. Conclusion: Including systematic analysis

  1. Automatic breast tissue density estimation scheme in digital mammography images

    Science.gov (United States)

    Menechelli, Renan C.; Pacheco, Ana Luisa V.; Schiabel, Homero

    2017-03-01

    Cases of breast cancer have increased substantially each year. However, radiologists are subject to subjectivity and failures of interpretation which may affect the final diagnosis in this examination. The high density features in breast tissue are important factors related to these failures. Thus, among many functions some CADx (Computer-Aided Diagnosis) schemes are classifying breasts according to the predominant density. In order to aid in such a procedure, this work attempts to describe automated software for classification and statistical information on the percentage change in breast tissue density, through analysis of sub regions (ROIs) from the whole mammography image. Once the breast is segmented, the image is divided into regions from which texture features are extracted. Then an artificial neural network MLP was used to categorize ROIs. Experienced radiologists have previously determined the ROIs density classification, which was the reference to the software evaluation. From tests results its average accuracy was 88.7% in ROIs classification, and 83.25% in the classification of the whole breast density in the 4 BI-RADS density classes - taking into account a set of 400 images. Furthermore, when considering only a simplified two classes division (high and low densities) the classifier accuracy reached 93.5%, with AUC = 0.95.

  2. High resolution MRI of the breast at 3 T: which BI-RADS registered descriptors are most strongly associated with the diagnosis of breast cancer?

    International Nuclear Information System (INIS)

    Pinker-Domenig, K.; Helbich, T.H.; Bogner, W.; Gruber, S.; Bickel, H.; Duffy, S.; Schernthaner, M.; Dubsky, P.; Pluschnig, U.; Rudas, M.; Trattnig, S.

    2012-01-01

    To identify which breast lesion descriptors in the ACR BI-RADS registered MRI lexicon are most strongly associated with the diagnosis of breast cancer when performing breast MR imaging at 3 T. 150 patients underwent breast MR imaging at 3 T. Lesion size, morphology and enhancement kinetics were assessed according to the BI-RADS registered classification. Sensitivity, specificity and diagnostic accuracy were assessed. The effects of the BI-RADS registered descriptors on sensitivity and specificity were evaluated. Data were analysed using logistic regression. Histopathological diagnoses were used as the standard of reference. The sensitivity, specificity and diagnostic accuracy of breast MRI at 3 T was 99%, 81% and 93%, respectively. In univariate analysis, the final diagnosis of malignancy was positively associated with irregular shape (p registered breast lesion descriptors that are mostly strongly associated with breast cancer in breast MR imaging at 3 T are lesion shape, lesion margin, internal enhancement pattern and Type 3 enhancement kinetics. (orig.)

  3. Identifying key radiogenomic associations between DCE-MRI and micro-RNA expressions for breast cancer

    Science.gov (United States)

    Samala, Ravi K.; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A.; Kim, Renaid

    2017-03-01

    Understanding the key radiogenomic associations for breast cancer between DCE-MRI and micro-RNA expressions is the foundation for the discovery of radiomic features as biomarkers for assessing tumor progression and prognosis. We conducted a study to analyze the radiogenomic associations for breast cancer using the TCGA-TCIA data set. The core idea that tumor etiology is a function of the behavior of miRNAs is used to build the regression models. The associations based on regression are analyzed for three study outcomes: diagnosis, prognosis, and treatment. The diagnosis group consists of miRNAs associated with clinicopathologic features of breast cancer and significant aberration of expression in breast cancer patients. The prognosis group consists of miRNAs which are closely associated with tumor suppression and regulation of cell proliferation and differentiation. The treatment group consists of miRNAs that contribute significantly to the regulation of metastasis thereby having the potential to be part of therapeutic mechanisms. As a first step, important miRNA expressions were identified and their ability to classify the clinical phenotypes based on the study outcomes was evaluated using the area under the ROC curve (AUC) as a figure-of-merit. The key mapping between the selected miRNAs and radiomic features were determined using least absolute shrinkage and selection operator (LASSO) regression analysis within a two-loop leave-one-out cross-validation strategy. These key associations indicated a number of radiomic features from DCE-MRI to be potential biomarkers for the three study outcomes.

  4. Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme.

    Science.gov (United States)

    Timmermans, Lore; Bleyen, Luc; Bacher, Klaus; Van Herck, Koen; Lemmens, Kim; Van Ongeval, Chantal; Van Steen, Andre; Martens, Patrick; De Brabander, Isabel; Goossens, Mathieu; Thierens, Hubert

    2017-09-01

    To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. • Interval cancer rate increases gradually with breast density, regardless of modality. • Cancer detection rate in high-density breasts is superior in DR. • IC rate exceeds CDR for SF and CR in high-density breasts. • DR performs better in high-density breasts for third readings and false-positives.

  5. Distinguishing benign and malignant breast tumors: preliminary comparison of kinetic modeling approaches using multi-institutional dynamic contrast-enhanced MRI data from the International Breast MR Consortium 6883 trial.

    Science.gov (United States)

    Sorace, Anna G; Partridge, Savannah C; Li, Xia; Virostko, Jack; Barnes, Stephanie L; Hippe, Daniel S; Huang, Wei; Yankeelov, Thomas E

    2018-01-01

    Comparative preliminary analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data collected in the International Breast MR Consortium 6883 multicenter trial was performed to distinguish benign and malignant breast tumors. Prebiopsy DCE-MRI data from 45 patients with suspicious breast lesions were obtained. Semiquantitative mean signal-enhancement ratio ([Formula: see text]) was calculated for all lesions, and quantitative pharmacokinetic, parameters [Formula: see text], [Formula: see text], and [Formula: see text], were calculated for the subset with available [Formula: see text] maps ([Formula: see text]). Diagnostic performance was estimated for DCE-MRI parameters and compared to standard clinical MRI assessment. Quantitative and semiquantitative metrics discriminated benign and malignant lesions, with receiver operating characteristic area under the curve (AUC) values of 0.71, 0.70, and 0.82 for [Formula: see text], [Formula: see text], and [Formula: see text], respectively ([Formula: see text]). At equal 94% sensitivity, the specificity and positive predictive value of [Formula: see text] (53% and 63%, respectively) and K trans (42% and 58%) were higher than clinical MRI assessment (32% and 54%). A multivariable model combining [Formula: see text] and clinical MRI assessment had an AUC value of 0.87. Quantitative pharmacokinetic and semiquantitative analyses of DCE-MRI improves discrimination of benign and malignant breast tumors, with our findings suggesting higher diagnostic accuracy using [Formula: see text]. [Formula: see text] has potential to help reduce unnecessary biopsies resulting from routine breast imaging.

  6. Breast Density Awareness and Knowledge, and Intentions for Breast Cancer Screening in a Diverse Sample of Women Age Eligible for Mammography.

    Science.gov (United States)

    Santiago-Rivas, Marimer; Benjamin, Shayna; Andrews, Janna Z; Jandorf, Lina

    2017-08-14

    The objectives of this study were to assess breast density knowledge and breast density awareness, and to identify information associated with intention to complete routine and supplemental screening for breast cancer in a diverse sample of women age eligible for mammography. We quantitatively (self-report) assessed breast density awareness and knowledge (N = 264) in black (47.7%), Latina (35.2%), and white (17%) women recruited online and in the community. Most participants reported having heard about breast density (69.2%); less than one third knew their own breast density status (30.4%). Knowing their own breast density, believing that women should be notified of their breast density in their mammogram report, and feeling informed if being provided this information are associated with likelihood of completing mammogram. Intending mammogram completion and knowledge regarding the impact of breast density on mammogram accuracy are associated with likelihood of completing supplemental ultrasound tests of the breast. These findings help inform practitioners and policy makers about information and communication factors that influence breast cancer screening concerns and decisions. Knowing this information should prepare practitioners to better identify women who may have not been exposed to breast density messages.

  7. Breast cancer MRI radiomics: An overview of algorithmic features and impact of inter-reader variability in annotating tumors.

    Science.gov (United States)

    Saha, Ashirbani; Harowicz, Michael R; Mazurowski, Maciej A

    2018-04-16

    To review features used in MRI radiomics of breast cancer and study the inter-reader stability of the features METHODS: We implemented 529 algorithmic features that can be extracted from tumor and fibroglandular tissue (FGT) in breast MRIs. The features were identified based on a review of the existing literature with consideration of their usage, prognostic ability, and uniqueness. The set was then extended so that it comprehensively describes breast cancer imaging characteristics. The features were classified into 10 groups based on the type of data used to extract them and the type of calculation being performed. For the assessment of inter-reader variability, 4 fellowship-trained readers annotated tumors on pre-operative dynamic contrast enhanced MRIs for 50 breast cancer patients. Based on the annotations, an algorithm automatically segmented the image and extracted all features resulting in one set of features for each reader. For a given feature, the inter-reader stability was defined as the intra-class correlation coefficient (ICC) computed using the feature values obtained through all readers for all cases. The average inter-reader stability for all features was 0.8474 (95% CI: 0.8068-0.8858). The mean inter-reader stability was lower for tumor-based features (0.6348, 95% CI: 0.5391-0.7257) than FGT-based features (0.9984, 95% CI: 0.9970-0.9992). The feature group with the highest inter-reader stability quantifies breast and FGT volume. The feature group with the lowest inter-reader stability quantifies variations in tumor enhancement. Breast MRI radiomics features widely vary in terms of their stability in the presence of inter-reader variability. Appropriate measures need to be taken for reducing this variability in tumor-based radiomics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Accuracy of multiecho magnitude-based MRI (M-MRI) for estimation of hepatic proton density fat fraction (PDFF) in children.

    Science.gov (United States)

    Zand, Kevin A; Shah, Amol; Heba, Elhamy; Wolfson, Tanya; Hamilton, Gavin; Lam, Jessica; Chen, Joshua; Hooker, Jonathan C; Gamst, Anthony C; Middleton, Michael S; Schwimmer, Jeffrey B; Sirlin, Claude B

    2015-11-01

    To assess accuracy of magnitude-based magnetic resonance imaging (M-MRI) in children to estimate hepatic proton density fat fraction (PDFF) using two to six echoes, with magnetic resonance spectroscopy (MRS) -measured PDFF as a reference standard. This was an IRB-approved, HIPAA-compliant, single-center, cross-sectional, retrospective analysis of data collected prospectively between 2008 and 2013 in children with known or suspected nonalcoholic fatty liver disease (NAFLD). Two hundred eighty-six children (8-20 [mean 14.2 ± 2.5] years; 182 boys) underwent same-day MRS and M-MRI. Unenhanced two-dimensional axial spoiled gradient-recalled-echo images at six echo times were obtained at 3T after a single low-flip-angle (10°) excitation with ≥ 120-ms recovery time. Hepatic PDFF was estimated using the first two, three, four, five, and all six echoes. For each number of echoes, accuracy of M-MRI to estimate PDFF was assessed by linear regression with MRS-PDFF as reference standard. Accuracy metrics were regression intercept, slope, average bias, and R(2) . MRS-PDFF ranged from 0.2-40.4% (mean 13.1 ± 9.8%). Using three to six echoes, regression intercept, slope, and average bias were 0.46-0.96%, 0.99-1.01, and 0.57-0.89%, respectively. Using two echoes, these values were 2.98%, 0.97, and 2.72%, respectively. R(2) ranged 0.98-0.99 for all methods. Using three to six echoes, M-MRI has high accuracy for hepatic PDFF estimation in children. © 2015 Wiley Periodicals, Inc.

  9. Correlation between MRI results and intraoperative findings in patients with silicone breast implants

    Directory of Open Access Journals (Sweden)

    Lindenblatt N

    2014-07-01

    Full Text Available Nicole Lindenblatt,1 Karem El-Rabadi,2 Thomas H Helbich,2 Heinrich Czembirek,3 Maria Deutinger,4 Heike Benditte-Klepetko5 1Division of Plastic and Hand Surgery, Department of Surgery, University Hospital Zurich, Zurich, Switzerland; 2Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna - General Hospital Vienna, 3Department of Radiology, Hospital Wiener Privatklinik, 4Department of Plastic and Reconstructive Surgery, Hospital Rudolfstiftung, Vienna, Austria; 5Department of Plastic and Reconstructive Surgery, Erasmus Medical Center, Rotterdam, the Netherlands Background: Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Methods: Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21–72 years, with a mean duration of implantation of 3.8 (range 1–28 years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Results: Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%. In seven of 17 removed implants (41%, the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Conclusion: Our results show that rupture of only the inner layers of the implant shell with integrity of

  10. Which factors influence MRI-pathology concordance of tumour size measurements in breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Rominger, M.; Frauenfelder, T. [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Berg, D. [Urbankrankenhaus Berlin, Anesthesiology, Berlin (Germany); Ramaswamy, A. [University Hospital Marburg, Pathology, Marburg (Germany); Timmesfeld, N. [Philipps University Marburg, Institute for Medical Biometry and Epidemiology, Marburg (Germany)

    2016-05-15

    To assess MRI-pathology concordance and factors influencing tumour size measurement in breast cancer. MRI tumour size (greatest diameter in anatomical planes (MRI-In-Plane) and greatest diameter along main tumour axis (MRI-MPR)) of 115 consecutive breast lesions (59 invasive lobular carcinoma, 46 invasive ductal carcinoma, and 10 ductal carcinoma in situ) was retrospectively compared to size measured at histopathology (pT size (Path-TNM) and greatest tumour diameter as relevant for excision (Path-Diameter; reference standard)). Histopathological tumour types, preoperative palpability, surgical management, additional high-risk lesions, and BI-RADS lesion type (mass versus non-mass enhancements) were assessed as possible influencing factors. Systematic errors were most pronounced between MRI-MPR and Path-TNM (7.1 mm, limits of agreement (LoA) [-21.7; 35.9]), and were lowest between MRI-In-Plane and Path-Diameter (0.2 mm, LoA [-19.7; 20.1]). Concordance rate of MRI-In-Plane with Path-Diameter was 86 % (97/113), overestimation 9 % (10/113) and underestimation 5 % (6/113); BI-RADS mass lesions were overestimated in 7 % (6/81) versus 41 % (13/32) for non-mass enhancements. On multivariate analysis only BI-RADS lesion type significantly influenced MRI-pathology concordance (p < 0.001). 2/59 (3 %) ILC did not enhance. Concordance rate varies according to the execution of MRI and histopathological measurements. Beyond this only non-mass enhancement significantly predicted discordance. (orig.)

  11. Monitoring tumor response to neoadjuvant chemotherapy using MRI and 18F-FDG PET/CT in breast cancer subtypes

    NARCIS (Netherlands)

    Schmitz, Alexander M Th; Teixeira, Suzana C; Pengel, Kenneth E; Loo, Claudette E; Vogel, Wouter V; Wesseling, Jelle; Rutgers, Emiel J Th; Valdés Olmos, Renato A; Sonke, Gabe S; Rodenhuis, Sjoerd; Vrancken Peeters, Marie Jeanne T F D; Gilhuijs, Kenneth G A

    2017-01-01

    PURPOSE: To explore guidelines on the use of MRI and PET/CT monitoring primary tumor response to neoadjuvant chemotherapy (NAC), taking breast cancer subtype into account. MATERIALS AND METHODS: In this prospective cohort study, 188 women were included with stages II and III breast cancer. MRI and

  12. Correlation between enhancement characteristics of MR mammography and capillary density of breast lesions

    International Nuclear Information System (INIS)

    Poellinger, Alexander; El-Ghannam, Sahra; Diekmann, Susanne; Fischer, Thomas; Kristiansen, Glen; Fritzsche, Florian; Fallenberg, Eva; Morawietz, Lars; Diekmann, Felix

    2014-01-01

    Highlights: • We correlate capillary density of breast lesions with MRM. • Capillary density correlates with tumor enhancement for all lesions. • However no such correlation exists for the malignant or benign groups separately. • Mean vessel number of lymphatic vessels do not correlate with tumor enhancement.These results might be of help in the workup of MR-guided breast biopsies. • These results might be of help in the workup of MR-guided breast biopsies. - Abstract: Objective: To correlate capillary density of breast lesions using the markers D2-40, CD31, and CD34 with early and late enhancement of magnetic resonance mammography (MRM). Materials and methods: The local ethics committee approved this study, and informed consent was available from all patients. The study included 64 women with 66 histologically proven breast lesions (41 malignant, 25 benign). MR-enhancement 1 min after contrast medium administration was determined in the tumor (I t1 /I t0 ratio) and in comparison to the surrounding tissue (I t1 /I t1-fat ratio). Capillary density was quantified based on immunohistological staining with D2-40, CD31, and CD34 in breast tumors and surrounding breast tissue. Mean capillary densities were correlated with contrast enhancement in the tumor and surrounding breast tissue. The Kruskal–Wallis test was used to test whether lesions with different MR enhancement patterns differed in terms of capillary density. Results: For CD34, there was statistically significant correlation between capillary density and tumor enhancement (r = 0.329, p = 0.012), however not for the malignant or benign groups separately. Mean vessel number identified by staining with D2-40 and CD31 did not correlate significantly with tumor enhancement (D2-40: r = −0.188, p = 0.130; CD31: r = 0.095, p = 0.448). There were no statistically significant differences in capillary density between breast lesions with delayed enhancement or a plateau and lesions showing washout (Kruskal

  13. Correlation between enhancement characteristics of MR mammography and capillary density of breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Poellinger, Alexander, E-mail: alexander.poellinger@charite.de [Charité, Universitätsmedizin Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin (Germany); El-Ghannam, Sahra; Diekmann, Susanne; Fischer, Thomas [Charité, Universitätsmedizin Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin (Germany); Kristiansen, Glen [Universitätsklinikum Bonn, Department of Pathology, Sigmund-Freud-Str. 25, D-53127 Bonn (Germany); Fritzsche, Florian [Institut für Histologie und Zytologie, Bahnhofplatz 11, Postfach, 9101 Herisau (Switzerland); Fallenberg, Eva [Charité, Universitätsmedizin Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin (Germany); Morawietz, Lars [Diagnostik Ernst von Bergmann GmbH, Charlottenstr. 72, 14467 Potsdam (Germany); Diekmann, Felix [Charité, Universitätsmedizin Berlin, Department of Radiology, Augustenburger Platz 1, 13353 Berlin (Germany)

    2014-12-15

    Highlights: • We correlate capillary density of breast lesions with MRM. • Capillary density correlates with tumor enhancement for all lesions. • However no such correlation exists for the malignant or benign groups separately. • Mean vessel number of lymphatic vessels do not correlate with tumor enhancement.These results might be of help in the workup of MR-guided breast biopsies. • These results might be of help in the workup of MR-guided breast biopsies. - Abstract: Objective: To correlate capillary density of breast lesions using the markers D2-40, CD31, and CD34 with early and late enhancement of magnetic resonance mammography (MRM). Materials and methods: The local ethics committee approved this study, and informed consent was available from all patients. The study included 64 women with 66 histologically proven breast lesions (41 malignant, 25 benign). MR-enhancement 1 min after contrast medium administration was determined in the tumor (I{sub t1}/I{sub t0} ratio) and in comparison to the surrounding tissue (I{sub t1}/I{sub t1-fat} ratio). Capillary density was quantified based on immunohistological staining with D2-40, CD31, and CD34 in breast tumors and surrounding breast tissue. Mean capillary densities were correlated with contrast enhancement in the tumor and surrounding breast tissue. The Kruskal–Wallis test was used to test whether lesions with different MR enhancement patterns differed in terms of capillary density. Results: For CD34, there was statistically significant correlation between capillary density and tumor enhancement (r = 0.329, p = 0.012), however not for the malignant or benign groups separately. Mean vessel number identified by staining with D2-40 and CD31 did not correlate significantly with tumor enhancement (D2-40: r = −0.188, p = 0.130; CD31: r = 0.095, p = 0.448). There were no statistically significant differences in capillary density between breast lesions with delayed enhancement or a plateau and lesions showing

  14. Combined use of 18F-FDG PET/CT and MRI for response monitoring of breast cancer during neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Koolen, Bas B.; Vogel, Wouter V.; Valdes Olmos, Renato A.; Wesseling, Jelle; Lips, Esther H.; Rutgers, Emiel J.T.; Vrancken Peeters, Marie Jeanne T.F.D.; Rodenhuis, Sjoerd; Gilhuijs, Kenneth G.A.

    2014-01-01

    To explore the potential complementary value of PET/CT and dynamic contrast-enhanced MRI in predicting pathological response to neoadjuvant chemotherapy (NAC) of breast cancer and the dependency on breast cancer subtype. We performed 18 F-FDG PET/CT and MRI examinations before and during NAC. The imaging features evaluated on both examinations included baseline and changes in 18 F-FDG maximum standardized uptake value (SUVmax) on PET/CT, and tumour morphology and contrast uptake kinetics on MRI. The outcome measure was a (near) pathological complete response ((near-)pCR) after surgery. Receiver operating characteristic curves with area under the curve (AUC) were used to evaluate the relationships between patient, tumour and imaging characteristics and tumour responses. Of 93 patients, 43 achieved a (near-)pCR. The responses varied among the different breast cancer subtypes. On univariate analysis the following variables were significantly associated with (near-)pCR: age (p = 0.033), breast cancer subtype (p < 0.001), relative change in SUVmax on PET/CT (p < 0.001) and relative change in largest tumour diameter on MRI (p < 0.001). The AUC for the relative reduction in SUVmax on PET/CT was 0.78 (95 % CI 0.68-0.88), and for the relative reduction in tumour diameter at late enhancement on MRI was 0.79 (95 % CI 0.70-0.89). The AUC increased to 0.90 (95 % CI 0.83-0.96) in the final multivariate model with PET/CT, MRI and breast cancer subtype combined (p = 0.012). PET/CT and MRI showed comparable value for monitoring response during NAC. Combined use of PET/CT and MRI had complementary potential. Research with more patients is required to further elucidate the dependency on breast cancer subtype. (orig.)

  15. A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Gudur, Madhu Sudhan Reddy; Hara, Wendy; Le, Quynh-Thu; Wang, Lei; Xing, Lei; Li, Ruijiang

    2014-01-01

    MRI significantly improves the accuracy and reliability of target delineation in radiation therapy for certain tumors due to its superior soft tissue contrast compared to CT. A treatment planning process with MRI as the sole imaging modality will eliminate systematic CT/MRI co-registration errors, reduce cost and radiation exposure, and simplify clinical workflow. However, MRI lacks the key electron density information necessary for accurate dose calculation and generating reference images for patient setup. The purpose of this work is to develop a unifying method to derive electron density from standard T1-weighted MRI. We propose to combine both intensity and geometry information into a unifying probabilistic Bayesian framework for electron density mapping. For each voxel, we compute two conditional probability density functions (PDFs) of electron density given its: (1) T1-weighted MRI intensity, and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of the atlas and test patient. The two conditional PDFs containing intensity and geometry information are combined into a unifying posterior PDF, whose mean value corresponds to the optimal electron density value under the mean-square error criterion. We evaluated the algorithm’s accuracy of electron density mapping and its ability to detect bone in the head for eight patients, using an additional patient as the atlas or template. Mean absolute HU error between the estimated and true CT, as well as receiver operating characteristics for bone detection (HU > 200) were calculated. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 126, compared with 139 for deformable registration (p = 2  ×  10 −4 ), 283 for the intensity approach (p = 2  ×  10 −6 ) and 282

  16. MRI findings and correlation with pathological features in breast phyllodes tumor

    International Nuclear Information System (INIS)

    Shen Xigang; Tan Hongna; Peng Weijun; Li Ruimin; Gu Yajia; Huang Dan; Mao Jian; Zhou Liangping

    2011-01-01

    Objective: To study the MR Imaging features of breast phyllodes tumor (PT), and to correlate it with pathological results. Method: Clinical and MRI findings were retrospectively reviewed in twenty-seven women with 28 PTs lesions confirmed by surgical pathology. Statistical analyses were one-way ANOVA for size analysis, Fisher exact test for analysis of MR appearances and Spearman correlation to study the relationship between MRI findings and BI-RADS categories. Results: (1) The histologic findings were benign, borderline and malignant PTs in 14.3% (4/28), 53.6% (15/28) and 32.1% (9/28) of lesions, respectively. (2) The mean maximum-diameter were (6.4±3.9) cm, (5.7±2.2) cm in borderline type and (4.8±1.8) cm in benign type respectively. The results showed differences in lesion's size among the three type (F= 287.541, P=0.000), especially between malignant and benign type (P=0.033). (3) Internal non-enhanced septation and silt-like changes on enhanced images, as well as time-signal curve on MRI correlated significantly with the histological grade (P<0.05). (4) If the category BI-RADS ≥ 4a was considered to be a suspicious sign for malignant lesion, the diagnostic accuracy of MRI would be 96.4% (27/28), and the BI-RADS category of the MRI could reflect the PT's histological grade with a low correlation coefficient (r=0.382, P=0.045). Conclusion: The findings of PT on MRI have some characteristics, with tumor size and several MRI features correlating with the histological grade of breast PT. (authors)

  17. Added Value of Breast MRI for Preoperative Diagnosis of Ductal Carcinoma In Situ: Diagnostic Performance on 362 Patients.

    Science.gov (United States)

    Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Triunfo, Flavia; Filice, Salvatore; Vallone, Paolo; Setola, Sergio Venanzio; Rubulotta, Mariarosaria; Di Bonito, Maurizio; Rinaldo, Massimo; D'Aiuto, Massimiliano; Brunetti, Arturo

    2017-06-01

    The purpose of this study was to evaluate the added value of breast magnetic resonance imaging (MRI) in preoperative diagnosis of ductal carcinoma in situ (DCIS). We reviewed our institution database of 3499 consecutive patients treated for breast cancer. A total of 362 patients with histologically proven DCIS were selected from the institutional database. Of these, 245 (67.7%) preoperatively underwent conventional imaging (CI) (mammography/ultrasonography) (CI group), and 117 (32.3%) underwent CI and dynamic MRI (CI + MRI group). The pathology of surgical specimens served as a reference standard. The Mann-Whitney U, χ 2 test, and Spearman correlation coefficient were performed. The CI + MRI group showed a sensitivity of 98.5% with an increase of 10.1% compared with the CI group to detect pure DCIS. Dynamic MRI identified 19.7% (n = 13) additional pure DCIS compared with CI. In the CI + MRI group, a single (1.5%) false negative was reported, whereas in the CI group, 11 (11.6%) false negatives were reported. Moreover, the CI + MRI group showed a sensitivity of 98.0% to detect DCIS + small invasive component. In this group, dynamic MRI identified 21.6% (n = 11) additional DCIS and a single (2.0%) false negative compared with the CI group, whereas in the CI group, 7 (4.7%) false negatives were reported. MRI and histopathologically measured lesion sizes, Breast Imaging Reporting and Data System MRI assessment categories, and enhancement signal intensity curve types showed a significant correlation. The MRI detection rate of DCIS increased significantly with increasing nuclear grade. Preoperative breast MRI showed a better accuracy then CI in preoperative diagnosis for both pure DCIS and DCIS + small invasive component with a precise assessment of lesion size. This can provide a more appropriate management of DCIS patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Lesion type and reader experience affect the diagnostic accuracy of breast MRI: A multiple reader ROC study

    Energy Technology Data Exchange (ETDEWEB)

    Baltzer, Pascal A.T., E-mail: patbaltzer@gmail.com [Department of Biomedical Imaging and Imge-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Kaiser, Werner Alois [Department of Diagnostic and Interventional Radiology, University Hospital Jena, Erlanger Allee 101, 07740 Jena (Germany); Dietzel, Matthias, E-mail: dietzelmatthias2@hotmail.com [Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054 Erlangen (Germany)

    2015-01-15

    Highlights: • The main findings of our study are, that reader experience and lesion type (i.e., mass versus non-mass enhancement) are independent predictors of the diagnostic accuracy of breast MRI. • Specifically, benign and malignant non-mass lesions cannot be differentiated with sufficient accuracy, especially if readers are not experienced. • We conclude that future research in breast MRI should focus on non-mass lesions, as these are the problem makers in modern breast MRI. - Abstract: Purpose: To evaluate the influence of lesion type (mass versus non-mass) and reader experience on the diagnostic performance of breast MRI (BMRI) in a non-screening setting. Materials and methods: Consecutive patients (mean age, 55 ± 12 years) with breast lesions that were verified by biopsy or surgery, and who had had BMRI as part of their diagnostic workup, were eligible for this retrospective single-center study. Cancers diagnosed by biopsy before BMRI were excluded to eliminate biological and interpretation bias due to biopsy or chemotherapy effects (n = 103). Six blinded readers (experience level, high (HE, n = 2); intermediate (IE, n = 2); and low (LE, n = 2)) evaluated all examinations and assigned independent MRI BI-RADS ratings. Lesion type (mass, non-mass, focal) was noted. Receiver operating characteristics (ROC) and logistic regression analysis was performed to compare diagnostic accuracies. Results: There were 259 histologically verified lesions (123 malignant, 136 benign) investigated. There were 169 mass (103 malignant, 66 benign) and 48 non-mass lesions (19 malignant, 29 benign). Another 42 lesions that met the inclusion criteria were biopsied due to conventional findings (i.e., microcalcifications, architectural distortions), but did not enhance on MRI (41 benign, one DCIS). ROC analysis revealed a total area under the curve (AUC) between 0.834 (LE) and 0.935 (HI). Logistic regression identified a significant effect of non-mass lesions (P < 0.0001) and

  19. Using surface markers for MRI guided breast conserving surgery: a feasibility survey

    Science.gov (United States)

    Ebrahimi, Mehran; Siegler, Peter; Modhafar, Amen; Holloway, Claire M. B.; Plewes, Donald B.; Martel, Anne L.

    2014-04-01

    Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient’s position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient’s arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient’s arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient’s arm is above the patient’s head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm3 in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion COM

  20. Using surface markers for MRI guided breast conserving surgery: a feasibility survey

    International Nuclear Information System (INIS)

    Ebrahimi, Mehran; Siegler, Peter; Modhafar, Amen; Martel, Anne L; Holloway, Claire M B; Plewes, Donald B

    2014-01-01

    Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient’s position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient’s arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient’s arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient’s arm is above the patient’s head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm 3 in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion

  1. [MRI findings and pathological features of occult breast cancer].

    Science.gov (United States)

    Zhang, J J; Yang, X T; Du, X S; Zhang, J X; Hou, L N; Niu, J L

    2018-01-23

    Objective: To investigate the magnetic resonance imaging (MRI) findings and clinicopathological features of primary lesions in patients with occult breast cancer (OBC). Methods: The imaging reports from the Breast Imaging Reporting and Data System in 2013 were retrospectively analyzed to investigate the morphology and the time signal intensity curve (TIC) of breast lesions in patients with OBC. The clinical and pathological characteristics of these patients were also included. Results: A total of 34 patients were enrolled. Among these patients, 24 patients underwent modified radical mastectomy and 18 of them had primary breast carcinoma in pathological sections. MRI detected 17 cases of primary lesions, including six masse lesions with a diameter of 0.6-1.2 cm (average 0.9 cm), and 11 non-mass lesions with four linear distributions, three segmental distributions, three focal distributions, and one regions distribution. Five patients had TIC typeⅠprimary lesions, ten had TIC type Ⅱ primary lesions, and two had TIC type Ⅲ primary lesions. Among all 34 cases, 23 of them had complete results of immunohistochemistry: 11 estrogen receptor (ER) positive lesions (47.8%), tenprogesterone receptor (PR) positive lesions (43.5%), seven human epidermal growth factor receptor 2 (HER-2) positive lesions (30.4%), and 20high expression(>14%) of Ki-67 (87.0%). The proportion of type luminal A was 4.3%, type luminal B was 43.5%, triple negative breast cancer (TNBC) was 30.4%, and HER-2 over expression accounted for 21.7%. Conclusions: The primary lesions of OBC usually manifested as small mass lesions, or focal, linear or segmental distribution of non-mass lesions. The positive rate of ER and PR was low, but the positive rate of HER-2 and the proliferation index of Ki-67 was high. Type luminal B is the most common molecular subtype.

  2. Background risk of breast cancer and the association between physical activity and mammographic density.

    Science.gov (United States)

    Trinh, Thang; Eriksson, Mikael; Darabi, Hatef; Bonn, Stephanie E; Brand, Judith S; Cuzick, Jack; Czene, Kamila; Sjölander, Arvid; Bälter, Katarina; Hall, Per

    2015-04-02

    High physical activity has been shown to decrease the risk of breast cancer, potentially by a mechanism that also reduces mammographic density. We tested the hypothesis that the risk of developing breast cancer in the next 10 years according to the Tyrer-Cuzick prediction model influences the association between physical activity and mammographic density. We conducted a population-based cross-sectional study of 38,913 Swedish women aged 40-74 years. Physical activity was assessed using the validated web-questionnaire Active-Q and mammographic density was measured by the fully automated volumetric Volpara method. The 10-year risk of breast cancer was estimated using the Tyrer-Cuzick (TC) prediction model. Linear regression analyses were performed to assess the association between physical activity and volumetric mammographic density and the potential interaction with the TC breast cancer risk. Overall, high physical activity was associated with lower absolute dense volume. As compared to women with the lowest total activity level (association was seen for any type of physical activity among women with association between total activity and absolute dense volume was modified by the TC breast cancer risk (P interaction = 0.05). As anticipated, high physical activity was also associated with lower non-dense volume. No consistent association was found between physical activity and percent dense volume. Our results suggest that physical activity may decrease breast cancer risk through reducing mammographic density, and that the physical activity needed to reduce mammographic density may depend on background risk of breast cancer.

  3. Area and volumetric density estimation in processed full-field digital mammograms for risk assessment of breast cancer.

    Directory of Open Access Journals (Sweden)

    Abbas Cheddad

    Full Text Available INTRODUCTION: Mammographic density, the white radiolucent part of a mammogram, is a marker of breast cancer risk and mammographic sensitivity. There are several means of measuring mammographic density, among which are area-based and volumetric-based approaches. Current volumetric methods use only unprocessed, raw mammograms, which is a problematic restriction since such raw mammograms are normally not stored. We describe fully automated methods for measuring both area and volumetric mammographic density from processed images. METHODS: The data set used in this study comprises raw and processed images of the same view from 1462 women. We developed two algorithms for processed images, an automated area-based approach (CASAM-Area and a volumetric-based approach (CASAM-Vol. The latter method was based on training a random forest prediction model with image statistical features as predictors, against a volumetric measure, Volpara, for corresponding raw images. We contrast the three methods, CASAM-Area, CASAM-Vol and Volpara directly and in terms of association with breast cancer risk and a known genetic variant for mammographic density and breast cancer, rs10995190 in the gene ZNF365. Associations with breast cancer risk were evaluated using images from 47 breast cancer cases and 1011 control subjects. The genetic association analysis was based on 1011 control subjects. RESULTS: All three measures of mammographic density were associated with breast cancer risk and rs10995190 (p0.10 for risk, p>0.03 for rs10995190. CONCLUSIONS: Our results show that it is possible to obtain reliable automated measures of volumetric and area mammographic density from processed digital images. Area and volumetric measures of density on processed digital images performed similar in terms of risk and genetic association.

  4. A novel method based on learning automata for automatic lesion detection in breast magnetic resonance imaging.

    Science.gov (United States)

    Salehi, Leila; Azmi, Reza

    2014-07-01

    Breast cancer continues to be a significant public health problem in the world. Early detection is the key for improving breast cancer prognosis. In this way, magnetic resonance imaging (MRI) is emerging as a powerful tool for the detection of breast cancer. Breast MRI presently has two major challenges. First, its specificity is relatively poor, and it detects many false positives (FPs). Second, the method involves acquiring several high-resolution image volumes before, during, and after the injection of a contrast agent. The large volume of data makes the task of interpretation by the radiologist both complex and time-consuming. These challenges have led to the development of the computer-aided detection systems to improve the efficiency and accuracy of the interpretation process. Detection of suspicious regions of interests (ROIs) is a critical preprocessing step in dynamic contrast-enhanced (DCE)-MRI data evaluation. In this regard, this paper introduces a new automatic method to detect the suspicious ROIs for breast DCE-MRI based on region growing. The results indicate that the proposed method is thoroughly able to identify suspicious regions (accuracy of 75.39 ± 3.37 on PIDER breast MRI dataset). Furthermore, the FP per image in this method is averagely 7.92, which shows considerable improvement comparing to other methods like ROI hunter.

  5. Mammographic breast density in recent and longer-standing ethiopian immigrants to israel.

    Science.gov (United States)

    Sklair-Levy, Miri; Segev, Anat; Sella, Tamar; Calderon-Margalit, Ronit; Zippel, Douglas

    2018-04-23

    High breast density is associated with an increased risk of breast cancer development. Little is known concerning ethnic variations in breast density and its relevant contributing factors. We aimed to study breast density among Ethiopian immigrants to Israel in comparison with Israeli-born women and to determine any effect on breast density of the length of residency in the immigrant population. Mammographic breast density using the BI-RADS system was estimated and compared between 77 women of Ethiopian origin who live in Israel and 177 Israeli-born controls. Logistic regression analysis was performed to estimate the odds ratios (OR) for high density (BI-RADS score ≥ 3) vs low density (BI-RADS score density compared with Israeli-born women. Adjustments for various cofounders did not affect the results. Time since immigration to Israel seemed to modify the relationship, with a stronger association for women who immigrated within 2 years prior to mammography (OR:0.07, 95% CI: 0.03-0.17) as opposed to women with a longer residency stay in Israel (OR:0.23, 95% CI:0.10-0.50). Adjustments of various confounders did not alter these findings. Breast density in Ethiopian immigrants to Israel is significantly lower than that of Israeli-born controls. Our study suggests a positive association between time since immigration and breast density. Future studies are required to define the possible effects of dietary change on mammographic density following immigration. © 2018 Wiley Periodicals, Inc.

  6. MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions

    Directory of Open Access Journals (Sweden)

    Vasilis Ntziachristos

    2002-01-01

    Full Text Available We present the clinical implementation of a novel hybrid system that combines magnetic resonance imaging (MRI and near-infrared (NIR optical measurements for the noninvasive study of breast cancer in vivo. Fourteen patients were studied with a MR-NIR prototype imager and spectrometer. A diffuse optical tomographic scheme employed the MR images as a priori information to implement an image-guided NIR localized spectroscopic scheme. All patients who entered the study also underwent gadolinium-enhanced MRI and biopsy so that the optical findings were crossvalidated with MR readings and histopathology. The technique quantified the oxy-and deoxyhemoglobin of five malignant and nine benign breast lesions in vivo. Breast cancers were found with decreased oxygen saturation and higher blood concentration than most benign lesions. The average hemoglobin concentration ([H] of cancers was 0.130±0.100 mM, and the average hemoglobin saturation (Y was 60±9% compared to [H]=0.018±0.005 mM and Y=69±6% of background tissue. Fibroadenomas exhibited high hemoglobin concentration [H]=0.060±0.010 mM and mild decrease in oxygen saturation Y=67±2%. Cysts and other normal lesions were easily differentiated based on intrinsic contrast information. This novel optical technology can be a significant add-on in MR examinations and can be used to characterize functional parameters of cancers with diagnostic and treatment prognosis potential. It is foreseen that the technique can play a major role in functional activation studies of brain and muscle as well.

  7. Monitoring tumor response to neoadjuvant chemotherapy using MRI and 18F-FDG PET/CT in breast cancer subtypes

    NARCIS (Netherlands)

    Schmitz, Alexander M. Th; Teixeira, Suzana C.; Pengel, Kenneth E.; Loo, Claudette E.; Vogel, Wouter V.; Wesseling, Jelle; Rutgers, Emiel J. Th; Valdés Olmos, Renato A.; Sonke, Gabe S.; Rodenhuis, Sjoerd; Vrancken Peeters, Marie Jeanne T. F. D.; Gilhuijs, Kenneth G. A.

    2017-01-01

    To explore guidelines on the use of MRI and PET/CT monitoring primary tumor response to neoadjuvant chemotherapy (NAC), taking breast cancer subtype into account. In this prospective cohort study, 188 women were included with stages II and III breast cancer. MRI and 18F-FDG-PET/CT were acquired

  8. Predicting Long-Term Cognitive Outcome Following Breast Cancer with Pre-Treatment Resting State fMRI and Random Forest Machine Learning.

    Science.gov (United States)

    Kesler, Shelli R; Rao, Arvind; Blayney, Douglas W; Oakley-Girvan, Ingrid A; Karuturi, Meghan; Palesh, Oxana

    2017-01-01

    We aimed to determine if resting state functional magnetic resonance imaging (fMRI) acquired at pre-treatment baseline could accurately predict breast cancer-related cognitive impairment at long-term follow-up. We evaluated 31 patients with breast cancer (age 34-65) prior to any treatment, post-chemotherapy and 1 year later. Cognitive testing scores were normalized based on data obtained from 43 healthy female controls and then used to categorize patients as impaired or not based on longitudinal changes. We measured clustering coefficient, a measure of local connectivity, by applying graph theory to baseline resting state fMRI and entered these metrics along with relevant patient-related and medical variables into random forest classification. Incidence of cognitive impairment at 1 year follow-up was 55% and was predicted by classification algorithms with up to 100% accuracy ( p breast cancer. This information could inform treatment decision making by identifying patients at highest risk for long-term cognitive impairment.

  9. In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port.

    Science.gov (United States)

    Linnemeyer, Hannah; Shellock, Frank G; Ahn, Christina Y

    2014-04-01

    A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port. A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences. Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7°C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located. A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Bone Mineral 31P and Matrix-Bound Water Densities Measured by Solid-State 1H and 31P MRI

    Science.gov (United States)

    Seifert, Alan C.; Li, Cheng; Rajapakse, Chamith S.; Bashoor- Zadeh, Mahdieh; Bhagat, Yusuf A.; Wright, Alexander C.; Zemel, Babette S.; Zavaliangos, Antonios; Wehrli, Felix W.

    2014-01-01

    Bone is a composite material consisting of mineral and hydrated collagen fractions. MRI of bone is challenging due to extremely short transverse relaxation times, but solid-state imaging sequences exist that can acquire the short-lived signal from bone tissue. Previous work to quantify bone density via MRI used powerful experimental scanners. This work seeks to establish the feasibility of MRI-based measurement on clinical scanners of bone mineral and collagen-bound water densities, the latter as a surrogate of matrix density, and to examine the associations of these parameters with porosity and donors’ age. Mineral and matrix-bound water images of reference phantoms and cortical bone from 16 human donors, ages 27-97 years, were acquired by zero-echo-time 31P and 1H MRI on whole body 7T and 3T scanners, respectively. Images were corrected for relaxation and RF inhomogeneity to obtain density maps. Cortical porosity was measured by micro-CT, and apparent mineral density by pQCT. MRI-derived densities were compared to x-ray-based measurements by least-squares regression. Mean bone mineral 31P density was 6.74±1.22 mol/L (corresponding to 1129±204 mg/cc mineral), and mean bound water 1H density was 31.3±4.2 mol/L (corresponding to 28.3±3.7 %v/v). Both 31P and bound water (BW) densities were correlated negatively with porosity (31P: R2 = 0.32, p bone mineralization ratio (expressed here as the ratio of 31P density to bound water density), which is proportional to true bone mineralization, was found to be uncorrelated with porosity, age, or pQCT density. This work establishes the feasibility of image-based quantification of bone mineral and bound water densities using clinical hardware. PMID:24846186

  11. Model-based estimation of breast percent density in raw and processed full-field digital mammography images from image-acquisition physics and patient-image characteristics

    Science.gov (United States)

    Keller, Brad M.; Nathan, Diane L.; Conant, Emily F.; Kontos, Despina

    2012-03-01

    Breast percent density (PD%), as measured mammographically, is one of the strongest known risk factors for breast cancer. While the majority of studies to date have focused on PD% assessment from digitized film mammograms, digital mammography (DM) is becoming increasingly common, and allows for direct PD% assessment at the time of imaging. This work investigates the accuracy of a generalized linear model-based (GLM) estimation of PD% from raw and postprocessed digital mammograms, utilizing image acquisition physics, patient characteristics and gray-level intensity features of the specific image. The model is trained in a leave-one-woman-out fashion on a series of 81 cases for which bilateral, mediolateral-oblique DM images were available in both raw and post-processed format. Baseline continuous and categorical density estimates were provided by a trained breast-imaging radiologist. Regression analysis is performed and Pearson's correlation, r, and Cohen's kappa, κ, are computed. The GLM PD% estimation model performed well on both processed (r=0.89, p<0.001) and raw (r=0.75, p<0.001) images. Model agreement with radiologist assigned density categories was also high for processed (κ=0.79, p<0.001) and raw (κ=0.76, p<0.001) images. Model-based prediction of breast PD% could allow for a reproducible estimation of breast density, providing a rapid risk assessment tool for clinical practice.

  12. Breast density does not impact the ability of Videssa® Breast to detect breast cancer in women under age 50.

    Directory of Open Access Journals (Sweden)

    David E Reese

    Full Text Available Breast density is associated with reduced imaging resolution in the detection of breast cancer. A biochemical approach that is not affected by density would provide an important tool to healthcare professionals who are managing women with dense breasts and suspicious imaging findings. Videssa® Breast is a combinatorial proteomic biomarker assay (CPBA, comprised of Serum Protein Biomarkers (SPB and Tumor Associated Autoantibodies (TAAb integrated with patient-specific clinical data to produce a diagnostic score that reliably detects breast cancer (BC as an adjunctive tool to imaging. The performance of Videssa® Breast was evaluated in the dense (a and b and non-dense (c and d groups in a population of n = 545 women under age 50. The sensitivity and specificity in the dense breast group were calculated to be 88.9% and 81.2%, respectively, and 92.3% and 86.6%, respectively, for the non-dense group. No significant differences were observed in the sensitivity (p = 1.0 or specificity (p = 0.18 between these groups. The NPV was 99.3% and 99.1% in non-dense and dense groups, respectively. Unlike imaging, Videssa® Breast does not appear to be impacted by breast density; it can effectively detect breast cancer in women with dense and non-dense breasts alike. Thus, Videssa® Breast provides a powerful tool for healthcare providers when women with dense breasts present with challenging imaging findings. In addition, Videssa® Breast provides assurance to women with dense breasts that they do not have breast cancer, reducing further anxiety in this higher risk patient population.

  13. Tailoring Breast Cancer Screening Intervals by Breast Density and Risk for Women Aged 50 Years or Older: Collaborative Modeling of Screening Outcomes.

    Science.gov (United States)

    Trentham-Dietz, Amy; Kerlikowske, Karla; Stout, Natasha K; Miglioretti, Diana L; Schechter, Clyde B; Ergun, Mehmet Ali; van den Broek, Jeroen J; Alagoz, Oguzhan; Sprague, Brian L; van Ravesteyn, Nicolien T; Near, Aimee M; Gangnon, Ronald E; Hampton, John M; Chandler, Young; de Koning, Harry J; Mandelblatt, Jeanne S; Tosteson, Anna N A

    2016-11-15

    Biennial screening is generally recommended for average-risk women aged 50 to 74 years, but tailored screening may provide greater benefits. To estimate outcomes for various screening intervals after age 50 years based on breast density and risk for breast cancer. Collaborative simulation modeling using national incidence, breast density, and screening performance data. United States. Women aged 50 years or older with various combinations of breast density and relative risk (RR) of 1.0, 1.3, 2.0, or 4.0. Annual, biennial, or triennial digital mammography screening from ages 50 to 74 years (vs. no screening) and ages 65 to 74 years (vs. biennial digital mammography from ages 50 to 64 years). Lifetime breast cancer deaths, life expectancy and quality-adjusted life-years (QALYs), false-positive mammograms, benign biopsy results, overdiagnosis, cost-effectiveness, and ratio of false-positive results to breast cancer deaths averted. Screening benefits and overdiagnosis increase with breast density and RR. False-positive mammograms and benign results on biopsy decrease with increasing risk. Among women with fatty breasts or scattered fibroglandular density and an RR of 1.0 or 1.3, breast cancer deaths averted were similar for triennial versus biennial screening for both age groups (50 to 74 years, median of 3.4 to 5.1 vs. 4.1 to 6.5 deaths averted; 65 to 74 years, median of 1.5 to 2.1 vs. 1.8 to 2.6 deaths averted). Breast cancer deaths averted increased with annual versus biennial screening for women aged 50 to 74 years at all levels of breast density and an RR of 4.0, and those aged 65 to 74 years with heterogeneously or extremely dense breasts and an RR of 4.0. However, harms were almost 2-fold higher. Triennial screening for the average-risk subgroup and annual screening for the highest-risk subgroup cost less than $100 000 per QALY gained. Models did not consider women younger than 50 years, those with an RR less than 1, or other imaging methods. Average-risk women

  14. Simultaneous whole-body 18F-FDG PET-MRI in primary staging of breast cancer: A pilot study

    International Nuclear Information System (INIS)

    Taneja, Sangeeta; Jena, Amarnath; Goel, Reema; Sarin, Ramesh; Kaul, Sumaid

    2014-01-01

    Highlights: • Initial staging of breast cancer important in treatment planning and prognostication. • We assessed role of simultaneous 18 F-FDG PET-MRI in initial staging of breast cancer. • Primary, nodes and metastases on PET, MRI and PET-MRI for count and diagnostic confidence. • High diagnostic accuracy and confidence in detecting index and satellite lesions. • Comprehensive nodal and distant metastases staging with altered management (12 cases). - Abstract: Purpose: Accurate initial staging in breast carcinoma is important for treatment planning and for establishing the likely prognosis. The purpose of this study was to assess the utility of whole body simultaneous 18 F-FDG PET-MRI in initial staging of breast carcinoma. Methods: 36 patients with histologically confirmed invasive ductal carcinoma underwent simultaneous whole body 18 F-FDG PET-MRI on integrated 3 T PET-MR scanner (Siemens Biograph mMR) for primary staging. Primary lesion, nodes and metastases were evaluated on PET, MRI and PET-MRI for lesion count and diagnostic confidence (DC). Kappa co relation analysis was done to assess agreement between the satellite, nodal and metastatic lesions detected by PET and MRI. Histopathology, clinical/imaging follow-up served as the reference standard. Results: 36 patients with 37 histopathologically proven index breast cancer were retrospectively studied. Of 36 patients, 25 patients underwent surgery and 11 patients received systemic therapy. All index cancers were seen on PET and MR. Fused PET-MRI showed highest diagnostic confidence score of 5 as compared to PET (median 4; range 3–5) and MRI (median 4; range 4–5) alone. 2/36 (5.5%) patients were detected to have unsuspected contralateral synchronous cancer. 47 satellite lesions were detected on DCE MRI of which 23 were FDG avid with multifocality and multicentricity in 21 (58%) patients. Kappa co relation analysis revealed fair agreement for satellite lesion detection by the two modalities (κ

  15. Real-Time MRI Navigated Ultrasound for Preoperative Tumor Evaluation in Breast Cancer Patients: Technique and Clinical Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355 (Korea, Republic of)

    2016-11-01

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  16. Real-time MRI navigated ultrasound for preoperative tumor evaluation in breast cancer patients: Technique and clinical implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2016-09-15

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  17. Breast MRI of ductal carcinoma in situ. Is there MRI role?

    International Nuclear Information System (INIS)

    Francescutti, G.E.; Londero, V.; Berra, I.; Del Frate, C.; Zuiani, C.; Bazzocchi, M.

    2002-01-01

    Background. The purpose of this study is to report our personal experience of 22 cases of ductal carcinoma in situ (DCIS) studied with magnetic resonance imaging (MRI). Patients and methods. From September 1995 to December 2001, 22 women diagnosed with DCIS lesions underwent contrast enhanced MRI within 7 days after mammographic examination. Dynamic MRI was performed with a 1 T system, using a three dimensional fast low angle shot (FLASH) pulse sequence before and after contrast media administration. We evaluated the morphologic features of the enhancement, the enhancement rate and the signal time intensity curve. Pathology was obtained in all cases. Results. The results of histopatological examination included: 15 DCIS and 7 DCIS with associated microinvasive component or microfoci of invasive ductal carcinoma (IDC). On MRI, 21 of 22 (95%) DCIS lesions showed contrast enhancement. Fourteen out of 15 pure DCIS lesions demonstrated respectively a low (3), undeterminate (5), and strong (6) enhancement. Morphologically, the enhancing lesion was focal in 7, segmental in 4, and with linear branching in 3 cases. Wash out was found in 4 cases, plateau curve in 8 and Type I curve in 2 cases. Multifocality was present in 5 cases. All DCIS with associated microinvasion demonstrated contrast enhancement: 1/7 cases showed a low enhancement, 2/7 showed an indeterminate enhancement and 4/7 showed a strong enhancement. Morphologically, the enhancing lesion was focal in 3/9, segmental in 5 and with linear branching in 1 case. The wash out was demonstrated in 3/7 cases, plateau curve in 3 and Type 1 curve in 1 case. Multifocality was present in 3 cases. Conclusions. In conclusion, the sensitivity of MRI for DCIS detection is lower than that achieved for invasive breast cancer; however, contrast-enhanced MRI can depict foci of DCIS that are mammographically occult. The MRI technique is of complementary value for a better description of tumor size and detection of additional

  18. Intra-observer agreement in single and joint double readings of contrast-enhanced breast MRI screening for women with high genetic breast cancer risks

    Directory of Open Access Journals (Sweden)

    Hugo C

    2013-04-01

    Full Text Available Objectives: To examine intra-observer reliability (IR for lesion detection on contrast-enhanced breast magnetic resonance images (MRI for screening women at high risk of breast cancer in single and joint double readings, without case selection. Methods: Contrast-enhanced breast MRIs were interpreted twice by the same independent reader and twice in joint readings. IR was assessed for lesion detection, normal MRI identification, mass, non-mass like enhancements (NMLE and focus characterisation, and BI-RADS assessment. Results: MRI examinations for 124 breasts, 65 women (mean age 43.4y were retrospectively reviewed with 110 lesions identified. Abnormal BIRADS (3-5 classifications were found for 52.3% in single readings and 58.5% in joint readings. Seven biopsies were performed for 4 histologically confirmed cancers. IR for BI-RADS classifications was good for single (0.63, 95% CI: 0.49-0.77, and joint readings (0.77, 95% CI: 0.61-0.93. IR for background parenchymal enhancement (BPE was moderate across single (0.53, 95% CI: 0.40-0.65 and joint readings (0.44, 95% CI: 0.33-0.56. IR for BI-RADS category according to each enhancement was poor for single (0.27, 95% CI: 0.10-0.44, and higher for joint readings, (0.58, 95% CI: 0.43-0.72. Conclusions: IR in BI-RADS breast assessments or BI-RADS lesion assessments are better with joint reading in screening for women with high genetic risks, in particular for abnormal MRI (BI-RADS 3, 4 and 5.

  19. Technical Note: Is bulk electron density assignment appropriate for MRI-only based treatment planning for lung cancer?

    Science.gov (United States)

    Prior, Phil; Chen, Xinfeng; Gore, Elizabeth; Johnstone, Candice; Li, X Allen

    2017-07-01

    MRI-based treatment planning in radiation therapy (RT) is prohibitive, in part, due to the lack of electron density (ED) information within the image. The dosimetric differences between MRI- and CT-based planning for intensity modulated RT (IMRT) of lung cancer were investigated to assess the appropriateness of bulk ED assignment. Planning CTs acquired for six representative lung cancer patients were used to generate bulk ED IMRT plans. To avoid the effect of anatomic differences between CT and MRI, "simulated MRI-based plans" were generated by forcing the relative ED (rED) to water on CT-delineated structures using organ specific values from the ICRU Report 46 and using the mean rED value of the internal target volume (ITV) from the planning CT. The "simulated MRI-based plans" were generated using a research planning system (Monaco v5.09.07a, Elekta, AB) and employing Monte Carlo dose calculation. The following dose-volume-parameters (DVPs) were collected from both the "simulated MRI-based plans" and the original planning CT: D 95 , the dose delivered to 95% of the ITV & planning target volume (PTV), D 5 and V 5 , the volume of normal lung irradiated ≥5 Gy. The percent point difference and relative dose difference were used for comparison with the CT based plan for V 5 and D 95 respectively. A total of five plans per patient were generated; three with the ITV rED (rED ITV ) = 1.06, 1.0 and the mean value from the planning CT while the lung rED (rED lung ) was fixed at the ICRU value of 0.26 and two with rED lung = 0.1 and 0.5 while the rED ITV was fixed to the mean value from the planning CT. Noticeable differences in the ITV and PTV DVPs were observed. Variations of the normal lung V 5 can be as large as 9.6%. In some instances, varying the rED ITV between rED mean and 1.06 resulted in D 95 increases ranging from 3.9% to 6.3%. Bulk rED assignment on normal lung affected the DVPs of the ITV and PTV by 4.0-9.8% and 0.3-19.6% respectively. Dose volume histograms

  20. Differentiation between benign and malignant breast lesions using quantitative diffusion-weighted sequence on 3 T MRI

    International Nuclear Information System (INIS)

    Tan, S.L.L.; Rahmat, K.; Rozalli, F.I.; Mohd-Shah, M.N.; Aziz, Y.F.A.; Yip, C.H.; Vijayananthan, A.; Ng, K.H.

    2014-01-01

    Aim: To investigate the capability and diagnostic accuracy of diffusion-weighted imaging (DWI) in differentiating benign from malignant breast lesions using 3 T magnetic resonance imaging (MRI). Materials and methods: Women with suspicious or indeterminate breast lesions detected at MRI, mammogram and/or ultrasound were recruited for dynamic contrast-enhanced (DCE)-MRI and DWI prior to their biopsy. Image fusion of DCE-MRI with apparent diffusion coefficient (ADC) map was utilized to select the region of interest (ROI) for ADC calculation in the area that showed the most avid enhancement. DWI was performed using two sets of b-values at 500 and 1000 s/mm 2 , respectively. Results: Fifty women were recruited and the final analysis comprised 44 breast lesions, 31 of which were malignant and 13 were benign. Significant results were obtained between ADC values of benign and malignant lesions (p −3 mm 2 /s for b = 500 s/mm 2 and 1.22 × 10 −3 mm 2 /s for b = 1000 s/mm 2 , respectively. The sensitivity of DCE-MRI alone was 100% with a specificity of 66.7%. When DCE-MRI was combined with b = 1000 s/mm 2 , the specificity rose to 100%, while only mildly affecting sensitivity (90.6%). No significant correlation was found between ADC values and prognostic factors, such as lymph node metastasis, tumour size, oestrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) status, and tumour grades. Conclusion: The present study provides consistent evidence to support DWI as a diagnostic tool for breast lesion characterization. A combination of DCE-MRI with DWI is suggested to improve the sensitivity and specificity of lesion characterization

  1. The contributions of breast density and common genetic variation to breast cancer risk.

    Science.gov (United States)

    Vachon, Celine M; Pankratz, V Shane; Scott, Christopher G; Haeberle, Lothar; Ziv, Elad; Jensen, Matthew R; Brandt, Kathleen R; Whaley, Dana H; Olson, Janet E; Heusinger, Katharina; Hack, Carolin C; Jud, Sebastian M; Beckmann, Matthias W; Schulz-Wendtland, Ruediger; Tice, Jeffrey A; Norman, Aaron D; Cunningham, Julie M; Purrington, Kristen S; Easton, Douglas F; Sellers, Thomas A; Kerlikowske, Karla; Fasching, Peter A; Couch, Fergus J

    2015-05-01

    We evaluated whether a 76-locus polygenic risk score (PRS) and Breast Imaging Reporting and Data System (BI-RADS) breast density were independent risk factors within three studies (1643 case patients, 2397 control patients) using logistic regression models. We incorporated the PRS odds ratio (OR) into the Breast Cancer Surveillance Consortium (BCSC) risk-prediction model while accounting for its attributable risk and compared five-year absolute risk predictions between models using area under the curve (AUC) statistics. All statistical tests were two-sided. BI-RADS density and PRS were independent risk factors across all three studies (P interaction = .23). Relative to those with scattered fibroglandular densities and average PRS (2(nd) quartile), women with extreme density and highest quartile PRS had 2.7-fold (95% confidence interval [CI] = 1.74 to 4.12) increased risk, while those with low density and PRS had reduced risk (OR = 0.30, 95% CI = 0.18 to 0.51). PRS added independent information (P Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  3. Design and characterization of Stormram 4 : an MRI-compatible robotic system for breast biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Veltman, Jeroen; Stramigioli, Stefano

    2017-01-01

    Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able

  4. A fully automated system for quantification of background parenchymal enhancement in breast DCE-MRI

    Science.gov (United States)

    Ufuk Dalmiş, Mehmet; Gubern-Mérida, Albert; Borelli, Cristina; Vreemann, Suzan; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    Background parenchymal enhancement (BPE) observed in breast dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been identified as an important biomarker associated with risk for developing breast cancer. In this study, we present a fully automated framework for quantification of BPE. We initially segmented fibroglandular tissue (FGT) of the breasts using an improved version of an existing method. Subsequently, we computed BPEabs (volume of the enhancing tissue), BPErf (BPEabs divided by FGT volume) and BPErb (BPEabs divided by breast volume), using different relative enhancement threshold values between 1% and 100%. To evaluate and compare the previous and improved FGT segmentation methods, we used 20 breast DCE-MRI scans and we computed Dice similarity coefficient (DSC) values with respect to manual segmentations. For evaluation of the BPE quantification, we used a dataset of 95 breast DCE-MRI scans. Two radiologists, in individual reading sessions, visually analyzed the dataset and categorized each breast into minimal, mild, moderate and marked BPE. To measure the correlation between automated BPE values to the radiologists' assessments, we converted these values into ordinal categories and we used Spearman's rho as a measure of correlation. According to our results, the new segmentation method obtained an average DSC of 0.81 0.09, which was significantly higher (p<0.001) compared to the previous method (0.76 0.10). The highest correlation values between automated BPE categories and radiologists' assessments were obtained with the BPErf measurement (r=0.55, r=0.49, p<0.001 for both), while the correlation between the scores given by the two radiologists was 0.82 (p<0.001). The presented framework can be used to systematically investigate the correlation between BPE and risk in large screening cohorts.

  5. Automated volumetric breast density estimation: A comparison with visual assessment

    International Nuclear Information System (INIS)

    Seo, J.M.; Ko, E.S.; Han, B.-K.; Ko, E.Y.; Shin, J.H.; Hahn, S.Y.

    2013-01-01

    Aim: To compare automated volumetric breast density (VBD) measurement with visual assessment according to Breast Imaging Reporting and Data System (BI-RADS), and to determine the factors influencing the agreement between them. Materials and methods: One hundred and ninety-three consecutive screening mammograms reported as negative were included in the study. Three radiologists assigned qualitative BI-RADS density categories to the mammograms. An automated volumetric breast-density method was used to measure VBD (% breast density) and density grade (VDG). Each case was classified into an agreement or disagreement group according to the comparison between visual assessment and VDG. The correlation between visual assessment and VDG was obtained. Various physical factors were compared between the two groups. Results: Agreement between visual assessment by the radiologists and VDG was good (ICC value = 0.757). VBD showed a highly significant positive correlation with visual assessment (Spearman's ρ = 0.754, p < 0.001). VBD and the x-ray tube target was significantly different between the agreement group and the disagreement groups (p = 0.02 and 0.04, respectively). Conclusion: Automated VBD is a reliable objective method to measure breast density. The agreement between VDG and visual assessment by radiologist might be influenced by physical factors

  6. Additional findings at preoperative breast MRI: the value of second-look digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola; Pancot, Martina; Girometti, Rossano; Bazzocchi, Massimo; Zuiani, Chiara [University of Udine, Azienda Ospedaliero-Universitaria, ' ' S.Maria della Misericordia' ' , Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, Udine (Italy); Carbonaro, Luca A. [IRCCS Policlinico San Donato, Unit of Radiology, Milan (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Unit of Radiology, Milan (Italy); Universita degli Studi di Milano, Department of Biomedical Sciences of Health, Milan (Italy)

    2015-10-15

    To evaluate second-look digital breast tomosynthesis (SL-DBT) for additional findings (AFs) at preoperative MRI compared with second-look ultrasound (SL-US). We included 135 patients with breast cancer who underwent digital mammography (DM), DBT, US, and MRI at two centres. MR images were retrospectively evaluated to find AFs, described as focus, mass, or non-mass; ≤10 mm or >10 mm in size; BI-RADS 3, 4, or 5. DM and DBT exams were reviewed looking for MRI AFs; data on SL-US were collected. Reference standard was histopathology or ≥12-month negative follow-up. Fisher exact test and McNemar test were used. Eighty-four AFs were detected in 53/135 patients (39 %, 95 %CI 31-48 %). A correlate was found for 44/84 (52 %, 95 %CI 41-63 %) at SL-US, for 20/84 (24 %, 95 %CI 11-28 %) at SL-DM, for 42/84 (50 %, 95 %CI 39-61 %) at SL-DBT, for 63/84 (75 %, 95 %CI 64-84 %) at SL-DBT, and/or SL-US, the last rate being higher than for SL-US only, overall (p < 0.001), for mass or non-mass, ≤ or >10 mm, BI-RADS 4 or 5, or malignant lesions (p < 0.031). Of 21 AFs occult at both SLs, 17 were malignant (81 %, 95 %CI 58-94 %). When adding SL-DBT to SL-US, AFs detection increased from 52 % to 75 %. MR-guided biopsy is needed for the remaining 25 %. (orig.)

  7. Quantification of breast density using dual-energy mammography with liquid phantom calibration

    International Nuclear Information System (INIS)

    Lam, Alfonso R; Ding, Huanjun; Molloi, Sabee

    2014-01-01

    Breast density is a widely recognized potential risk factor for breast cancer. However, accurate quantification of breast density is a challenging task in mammography. The current use of plastic breast-equivalent phantoms for calibration provides limited accuracy in dual-energy mammography due to the chemical composition of the phantom. We implemented a breast-equivalent liquid phantom for dual-energy calibration in order to improve the accuracy of breast density measurement. To design these phantoms, three liquid compounds were chosen: water, isopropyl alcohol, and glycerol. Chemical compositions of glandular and adipose tissues, obtained from NIST database, were used as reference materials. Dual-energy signal of the liquid phantom at different breast densities (0% to 100%) and thicknesses (1 to 8 cm) were simulated. Glandular and adipose tissue thicknesses were estimated from a higher order polynomial of the signals. Our results indicated that the linear attenuation coefficients of the breast-equivalent liquid phantoms match those of the target material. Comparison between measured and known breast density data shows a linear correlation with a slope close to 1 and a non-zero intercept of 7%, while plastic phantoms showed a slope of 0.6 and a non-zero intercept of 8%. Breast density results derived from the liquid calibration phantoms showed higher accuracy than those derived from the plastic phantoms for different breast thicknesses and various tube voltages. We performed experimental phantom studies using liquid phantoms and then compared the computed breast density with those obtained using a bovine tissue model. The experimental data and the known values were in good correlation with a slope close to 1 (∼1.1). In conclusion, our results indicate that liquid phantoms are a reliable alternative for calibration in dual-energy mammography and better reproduce the chemical properties of the target material. (paper)

  8. 3T MRI of the breast with computer aided diagnosis, can it help to ...

    African Journals Online (AJOL)

    Objective: This study aimed to check the sensitivity of multiple newly developed 3T MRI breast sequences using CAD software, in pre sampling diagnosis of breast cancer, in an attempt to minimize unnecessary invasive sampling or surgical procedures. Patients and methods: This was a prospective study, included 120 ...

  9. Semiautomatic estimation of breast density with DM-Scan software.

    Science.gov (United States)

    Martínez Gómez, I; Casals El Busto, M; Antón Guirao, J; Ruiz Perales, F; Llobet Azpitarte, R

    2014-01-01

    To evaluate the reproducibility of the calculation of breast density with DM-Scan software, which is based on the semiautomatic segmentation of fibroglandular tissue, and to compare it with the reproducibility of estimation by visual inspection. The study included 655 direct digital mammograms acquired using craniocaudal projections. Three experienced radiologists analyzed the density of the mammograms using DM-Scan, and the inter- and intra-observer agreement between pairs of radiologists for the Boyd and BI-RADS® scales were calculated using the intraclass correlation coefficient. The Kappa index was used to compare the inter- and intra-observer agreements with those obtained previously for visual inspection in the same set of images. For visual inspection, the mean interobserver agreement was 0,876 (95% CI: 0,873-0,879) on the Boyd scale and 0,823 (95% CI: 0,818-0,829) on the BI-RADS® scale. The mean intraobserver agreement was 0,813 (95% CI: 0,796-0,829) on the Boyd scale and 0,770 (95% CI: 0,742-0,797) on the BI-RADS® scale. For DM-Scan, the mean inter- and intra-observer agreement was 0,92, considerably higher than the agreement for visual inspection. The semiautomatic calculation of breast density using DM-Scan software is more reliable and reproducible than visual estimation and reduces the subjectivity and variability in determining breast density. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  10. Breast Density Notification Legislation and Breast Cancer Stage at Diagnosis: Early Evidence from the SEER Registry.

    Science.gov (United States)

    Richman, Ilana; Asch, Steven M; Bendavid, Eran; Bhattacharya, Jay; Owens, Douglas K

    2017-06-01

    Twenty-eight states have passed breast density notification laws, which require physicians to inform women of a finding of dense breasts on mammography. To evaluate changes in breast cancer stage at diagnosis after enactment of breast density notification legislation. Using a difference-in-differences analysis, we examined changes in stage at diagnosis among women with breast cancer in Connecticut, the first state to enact legislation, compared to changes among women in control states. We used data from the Surveillance, Epidemiology, and End Results Program (SEER) registry, 2005-2013. Women ages 40-74 with breast cancer. Breast density notification legislation, enacted in Connecticut in October of 2009. Breast cancer stage at diagnosis. Our study included 466,930 women, 25,592 of whom lived in Connecticut. Legislation was associated with a 1.38-percentage-point (95 % CI 0.12 to 2.63) increase in the proportion of women in Connecticut versus control states who had localized invasive cancer at the time of diagnosis, and a 1.12-percentage-point (95 % CI -2.21 to -0.08) decline in the proportion of women with ductal carcinoma in situ at diagnosis. Breast density notification legislation was not associated with a change in the proportion of women in Connecticut versus control states with regional-stage (-0.09 percentage points, 95 % CI -1.01 to 1.02) or metastatic disease (-0.24, 95 % CI -0.75 to 0.28). County-level analyses and analyses limited to women younger than 50 found no statistically significant associations. Single intervention state, limited follow-up, potential confounding from unobserved trends. Breast density notification legislation in Connecticut was associated with a small increase in the proportion of women diagnosed with localized invasive breast cancer in individual-level but not county-level analyses. Whether this finding reflects potentially beneficial early detection or potentially harmful overdiagnosis is not known. Legislation was not

  11. Assessment of three different software systems in the evaluation of dynamic MRI of the breast

    International Nuclear Information System (INIS)

    Kurz, K.D.; Steinhaus, D.; Klar, V.; Cohnen, M.; Wittsack, H.J.; Saleh, A.; Moedder, U.; Blondin, D.

    2009-01-01

    Objective: The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ('CADstream' and '3TP') and one self-developed software system ('Mammatool'). Materials and methods: Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. Results: There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. 'CADstream' showed the best score on subjective quality criteria. '3TP' showed the lowest number of false-positive results. 'Mammatool' produced the lowest number of benign tissues indicated with parametric overlay. Conclusion: All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable

  12. Assessment of three different software systems in the evaluation of dynamic MRI of the breast.

    Science.gov (United States)

    Kurz, K D; Steinhaus, D; Klar, V; Cohnen, M; Wittsack, H J; Saleh, A; Mödder, U; Blondin, D

    2009-02-01

    The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ("CADstream" and "3TP") and one self-developed software system ("Mammatool"). Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. "CADstream" showed the best score on subjective quality criteria. "3TP" showed the lowest number of false-positive results. "Mammatool" produced the lowest number of benign tissues indicated with parametric overlay. All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable.

  13. InforMD: a new initiative to raise public awareness about breast density.

    Science.gov (United States)

    Hugo, Honor J; Zysk, Aneta; Dasari, Pallave; Britt, Kara; Hopper, John L; Stone, Jennifer; Thompson, Erik W; Ingman, Wendy V

    2018-01-01

    On a mammogram, breast density (also known as mammographic density) is shown as white and bright regions and is associated with reduced sensitivity in cancer detection and increased breast cancer risk. However, many Australian women are unaware of the significance of breast density as it is not routinely reported or discussed. In order to address this lack of knowledge, Australian breast cancer researchers with expertise in mammographic density formed the InforMD alliance (INformation FORum on Mammographic Density) in 2016. The alliance is working to raise awareness of breast density with the goal of improving breast cancer diagnosis and health outcomes for women. The InforMD website (www.InforMD.org.au) was launched in October 2016, coinciding with a major nationwide public awareness campaign by the alliance during breast cancer awareness month. The website contains unbiased, accurate, updated information on breast density. The website also provides summaries of major research articles in layperson language, recent news items related to breast density, links to relevant information for health professionals, events, and feature articles. Members of the public and health professionals can also subscribe for news updates. The interactive online Forum section facilitates discussion between health professionals, scientists and members of the public. To increase online traffic to the website, Facebook (www.facebook.com/BeInforMD) and Twitter (https://twitter.com/BeInforMD_) pages were launched in December 2016. Since its launch, InforMD has generated considerable interest. The public awareness campaign reached over 7 million Australians through a combination of newspaper, TV, radio, and online news. The website has attracted 13,058 unique visitors and 30,353 page views (data as of 19/12/2017). Breast cancer researchers have a significant role to play in disseminating information to the public on breast density. A combination of mainstream and social media, together with

  14. Variability of breast density assessment in short-term reimaging with digital mammography

    International Nuclear Information System (INIS)

    Kim, Won Hwa; Moon, Woo Kyung; Kim, Sun Mi; Yi, Ann; Chang, Jung Min; Koo, Hye Ryoung; Lee, Su Hyun; Cho, Nariya

    2013-01-01

    Objective: To evaluate the variability of breast density assessments in short-term reimaging with digital mammography. Materials and methods: In 186 women, short term (mean interval, 27.6 days) serial digital mammograms including CC and MLO views were obtained without any treatment. Mammographic density assessments were performed by three blinded radiologists for Breast Imaging Report and Data System (BI-RADS, grades 1–4) and visual percentage density (PD) estimation, and by one radiologist for computer-aided PD estimation. The variability of assessments was analyzed according to the age, breast density, and mammography types by multivariate logistic regression. Results: In BI-RADS assessments, 29% (161 of 558) of breast density categories were assessed differently after short-term reimaging and the mean absolute difference in PD for CC and MLO view was 7.6% and 8.1% for visual assessments, and 7.4% and 6.4% for computer-aided assessments, respectively. Among all computer-aided assessments, 29% (54 of 186) of CC view and 22% (41 of 186) of MLO view assessments had discrepancy over 10% in PD. Younger age (<50), greater breast density (grades 3 and 4), and different mammography types were significantly associated with the variability. Conclusion: Considerable variability in breast density assessments occurred in short-term reimaging with digital mammography, particularly in women with younger age and greater breast density and when examined using different types of mammography

  15. Variability of breast density assessment in short-term reimaging with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Moon, Woo Kyung, E-mail: moonwk@snu.ac.kr [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Sun Mi [Department of Radiology, Seoul National University Bundang Hospital, Gyeonggi-do (Korea, Republic of); Yi, Ann [Department of Radiology, Seoul Metropolitan Government Seoul National University, Boramae Medical Center, Seoul (Korea, Republic of); Chang, Jung Min; Koo, Hye Ryoung; Lee, Su Hyun; Cho, Nariya [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-10-01

    Objective: To evaluate the variability of breast density assessments in short-term reimaging with digital mammography. Materials and methods: In 186 women, short term (mean interval, 27.6 days) serial digital mammograms including CC and MLO views were obtained without any treatment. Mammographic density assessments were performed by three blinded radiologists for Breast Imaging Report and Data System (BI-RADS, grades 1–4) and visual percentage density (PD) estimation, and by one radiologist for computer-aided PD estimation. The variability of assessments was analyzed according to the age, breast density, and mammography types by multivariate logistic regression. Results: In BI-RADS assessments, 29% (161 of 558) of breast density categories were assessed differently after short-term reimaging and the mean absolute difference in PD for CC and MLO view was 7.6% and 8.1% for visual assessments, and 7.4% and 6.4% for computer-aided assessments, respectively. Among all computer-aided assessments, 29% (54 of 186) of CC view and 22% (41 of 186) of MLO view assessments had discrepancy over 10% in PD. Younger age (<50), greater breast density (grades 3 and 4), and different mammography types were significantly associated with the variability. Conclusion: Considerable variability in breast density assessments occurred in short-term reimaging with digital mammography, particularly in women with younger age and greater breast density and when examined using different types of mammography.

  16. Predicting local recurrence following breast-conserving treatment: parenchymal signal enhancement ratio (SER) around the tumor on preoperative MRI

    International Nuclear Information System (INIS)

    Kim, Mi Young; Cho, Nariya; Koo, Hye Ryoung; Yun, Bo La; Bae, Min Sun; Moon, Woo Kyung; Chie, Eui Kyu

    2013-01-01

    Background: The level of background parenchymal enhancement around tumor is known to be associated with breast cancer risk. However, there is no study investigating predictive power of parenchymal signal enhancement ratio (SER) around tumor for ipsilateral breast tumor recurrence (IBTR). Purpose: To investigate whether the breast parenchymal SER around the tumor on preoperative dynamic contrast-enhanced magnetic resonance imaging (MRI) is associated with subsequent IBTR in breast cancer patients who had undergone breast-conserving treatment. Material and Methods: Nineteen consecutive women (mean age, 44 years; range, 34-63 years) with breast cancer who developed IBTR following breast-conserving treatment and 114 control women matched for age, as well as T and N stages were included. We compared the clinicopathologic features of the two groups including nuclear grade, histologic grade, hormonal receptor status, human epidermal growth factor receptor-2 (HER-2) status, lymphovascular invasion, negative margin width, use of adjuvant therapy, and parenchymal SER around the tumor on preoperative DCE-MRI. The SER was measured on a slice showing the largest dimension of the tumor. Multivariate conditional logistic regression analysis was used to identify independent factors associated with IBTR. Results: In univariate analysis, ER negativity (odds ratio [OR] = 4.7; P = 0.040), PR negativity (OR = 4.0; P = 0.013), HER-2 positivity (OR = 3.6; P = 0.026), and a parenchymal SER greater than 0.53 (OR = 23.3; P = 0.011) were associated with IBTR. In multivariate analysis, ER negativity (OR = 3.8; P = 0.015) and a parenchymal SER greater than 0.53 (OR = 13.2; P = 0.040) on preoperative MRI were independent factors associated with IBTR. Conclusion: In addition to ER negativity, a higher parenchymal SER on preoperative MRI was an independent factor associated with subsequent IBTR in patients with breast cancer who had undergone breast-conserving treatment

  17. Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?

    Science.gov (United States)

    Sanabria, Sergio J; Goksel, Orcun; Martini, Katharina; Forte, Serafino; Frauenfelder, Thomas; Kubik-Huch, Rahel A; Rominger, Marga B

    2018-03-19

    To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories. ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US. A reflector served as timing reference for US signals transmitted through the breasts. Four blinded readers assessed average SoS (m/s), ΔSoS (segment-variation SoS; m/s) and the ACR-MG density. The highest SoS and ΔSoS values of the three segments were used for MG-ACR whole breast comparison. SoS-US breasts were examined in densities a-d were 1,421 m/s (SD 14), 1,432 m/s (SD 17), 1,448 m/s (SD 20) and 1,500 m/s (SD 31), with significant differences between all groups (pdensity was evident (r s =0.622, p=density without discomfort, readers evaluated measurements with high inter-reader agreement, and SoS-US correlated significantly with ACR-MG breast-density categories. • The novel speed-of-sound ultrasound correlated significantly with mammographic ACR breast density categories. • Radiographers measured breast density without women discomfort or radiation. • SoS-US can be implemented on a standard US machine. • SoS-US shows potential for a quantifiable, cost-effective assessment of breast density.

  18. Evaluating Surveillance Breast Imaging and Biopsy in Older Breast Cancer Survivors

    Directory of Open Access Journals (Sweden)

    Tracy Onega

    2012-01-01

    Full Text Available Background. Patterns of surveillance among breast cancer survivors are not well characterized and lack evidence-based practice guidelines, particularly for imaging modalities other than mammography. We characterized breast imaging and related biopsy longitudinally among breast cancer survivors in relation to women’s characteristics. Methods. Using data from a state-wide (New Hampshire breast cancer screening registry linked to Medicare claims, we examined use of mammography, ultrasound (US, magnetic resonance imaging (MRI, and biopsy among breast cancer survivors. We used generalized estimating equations (GEE to model associations of breast surveillance with women’s characteristics. Results. The proportion of women with mammography was high over the follow-up period (81.5% at 78 months, but use of US or MRI was much lower (8.0%—first follow-up window, 4.7% by 78 months. Biopsy use was consistent throughout surveillance periods (7.4%–9.4%. Surveillance was lower among older women and for those with a higher stage of diagnosis. Primary therapy was significantly associated with greater likelihood of breast surveillance. Conclusions. Breast cancer surveillance patterns for mammography, US, MRI, and related biopsy seem to be associated with age, stage, and treatment, but need a larger evidence-base for clinical recommendations.

  19. Breast Tissue Composition and Immunophenotype and Its Relationship with Mammographic Density in Women at High Risk of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Jia-Min B Pang

    Full Text Available To investigate the cellular and immunophenotypic basis of mammographic density in women at high risk of breast cancer.Mammograms and targeted breast biopsies were accrued from 24 women at high risk of breast cancer. Mammographic density was classified into Wolfe categories and ranked by increasing density. The histological composition and immunophenotypic profile were quantified from digitized haematoxylin and eosin-stained and immunohistochemically-stained (ERα, ERβ, PgR, HER2, Ki-67, and CD31 slides and correlated to mammographic density.Increasing mammographic density was significantly correlated with increased fibrous stroma proportion (rs (22 = 0.5226, p = 0.0088 and significantly inversely associated with adipose tissue proportion (rs (22 = -0.5409, p = 0.0064. Contrary to previous reports, stromal expression of ERα was common (19/20 cases, 95%. There was significantly higher stromal PgR expression in mammographically-dense breasts (p=0.026.The proportion of stroma and fat underlies mammographic density in women at high risk of breast cancer. Increased expression of PgR in the stroma of mammographically dense breasts and frequent and unexpected presence of stromal ERα expression raises the possibility that hormone receptor expression in breast stroma may have a role in mediating the effects of exogenous hormonal therapy on mammographic density.

  20. Supplemental Screening for Breast Cancer in Women With Dense Breasts: A Systematic Review for the U.S. Preventive Services Task Force.

    Science.gov (United States)

    Melnikow, Joy; Fenton, Joshua J; Whitlock, Evelyn P; Miglioretti, Diana L; Weyrich, Meghan S; Thompson, Jamie H; Shah, Kunal

    2016-02-16

    Screening mammography has lower sensitivity and specificity in women with dense breasts, who experience higher breast cancer risk. To perform a systematic review of reproducibility of Breast Imaging Reporting and Data System (BI-RADS) density categorization and test performance and clinical outcomes of supplemental screening with breast ultrasonography, magnetic resonance imaging (MRI), and digital breast tomosynthesis (DBT) in women with dense breasts and negative mammography results. MEDLINE, PubMed, EMBASE, and Cochrane database from January 2000 to July 2015. Studies reporting BI-RADS density reproducibility or supplemental screening results for women with dense breasts. Quality assessment and abstraction of 24 studies from 7 countries; 6 studies were good-quality. Three good-quality studies reported reproducibility of BI-RADS density; 13% to 19% of women were recategorized between "dense" and "nondense" at subsequent screening. Two good-quality studies reported that sensitivity of ultrasonography for women with negative mammography results ranged from 80% to 83%; specificity, from 86% to 94%; and positive predictive value (PPV), from 3% to 8%. The sensitivity of MRI ranged from 75% to 100%; specificity, from 78% to 94%; and PPV, from 3% to 33% (3 studies). Rates of additional cancer detection with ultrasonography were 4.4 per 1000 examinations (89% to 93% invasive); recall rates were 14%. Use of MRI detected 3.5 to 28.6 additional cancer cases per 1000 examinations (34% to 86% invasive); recall rates were 12% to 24%. Rates of cancer detection with DBT increased by 1.4 to 2.5 per 1000 examinations compared with mammography alone (3 studies). Recall rates ranged from 7% to 11%, compared with 7% to 17% with mammography alone. No studies examined breast cancer outcomes. Good-quality evidence was sparse. Studies were small and CIs were wide. Definitions of recall were absent or inconsistent. Density ratings may be recategorized on serial screening mammography

  1. Age as a predictive factor of mammographic breast density in Jamaican women

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-06-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P < 0.001). Women with low breast density were heavier (81.3 {+-} 15.5 kg vs 68.4 {+-} 14.3 kg,P < 0.0001, mean {+-} standard deviation (SD)) and more obese (body mass index (BMI), 30.3 {+-} 5.8 kg m{sup -2} vs 26.0 {+-} 5.2 kg m{sup -2}, P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  2. Effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy

    International Nuclear Information System (INIS)

    Kawashima, Hiroko; Tawara, Mari; Suzuki, Masayuki; Matsui, Osamu; Kadoya, Masumi

    2001-01-01

    The purpose of this study was to investigate the effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy. Twenty-six patients who underwent excisional biopsy of a tumor or calcified lesion of the breast underwent gadolinium-enhanced dynamic MRI by the fat-saturated 2D fast spoiled gradient echo (SPGR) sequence (group 1), 24 patients by the spectral IR enhanced 3D fast gradient echo (Efgre3d) sequence (group 2). Pericicatricial residual cancer was confirmed histologically in 29 of the 50 patients. The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRI for residual cancer diagnosis was 66, 81, 72, 83 and 63%. A nodular, thick and discontinuous enhanced rim around the scar is indicative of a residual tumor. However, false-positive findings due to granulation or proliferative fibrocystic change remain limitations

  3. Effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, Hiroko E-mail: hirokok@med.kanazawa-u.ac.jp; Tawara, Mari; Suzuki, Masayuki; Matsui, Osamu; Kadoya, Masumi

    2001-10-01

    The purpose of this study was to investigate the effectiveness of dynamic MRI for diagnosing pericicatricial minimal residual breast cancer following excisional biopsy. Twenty-six patients who underwent excisional biopsy of a tumor or calcified lesion of the breast underwent gadolinium-enhanced dynamic MRI by the fat-saturated 2D fast spoiled gradient echo (SPGR) sequence (group 1), 24 patients by the spectral IR enhanced 3D fast gradient echo (Efgre3d) sequence (group 2). Pericicatricial residual cancer was confirmed histologically in 29 of the 50 patients. The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MRI for residual cancer diagnosis was 66, 81, 72, 83 and 63%. A nodular, thick and discontinuous enhanced rim around the scar is indicative of a residual tumor. However, false-positive findings due to granulation or proliferative fibrocystic change remain limitations.

  4. Awareness of breast density and its impact on breast cancer detection and risk.

    Science.gov (United States)

    Rhodes, Deborah J; Radecki Breitkopf, Carmen; Ziegenfuss, Jeanette Y; Jenkins, Sarah M; Vachon, Celine M

    2015-04-01

    Legislation mandating disclosure of breast density (BD) information has passed in 21 states; however, actual awareness of BD and knowledge of its impact on breast cancer detection and risk are unknown. We conducted a national cross-sectional survey administered in English and Spanish using a probability-based sample of screening-age women, with oversampling of Connecticut, the only state with BD legislation in effect for > 1 year before the survey. Of 2,311 women surveyed, 65% responded. Overall, 58% of women had heard of BD, 49% knew that BD affects breast cancer detection, and 53% knew that BD affects cancer risk. After multivariable adjustment, increased BD awareness was associated with white non-Hispanic race/ethnicity (Hispanic v white non-Hispanic: odds ratio [OR], 0.23; P awareness and knowledge exist by race/ethnicity, education, and income. BD legislation seems to be effective in increasing knowledge of BD impact on breast cancer detection. These findings support continued and targeted efforts to improve BD awareness and knowledge among women eligible for screening mammography. © 2015 by American Society of Clinical Oncology.

  5. Comparison of pharmacokinetic MRI and [18F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    International Nuclear Information System (INIS)

    Brix, G.; Henze, M.; Knopp, M.V.; Doll, J.; Hawighorst, H.; Lucht, R.; Junkermann, H.; Haberkorn, U.

    2001-01-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  6. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  7. Age as a predictive factor of mammographic breast density in Jamaican women

    International Nuclear Information System (INIS)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-01-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P -2 vs 26.0 ± 5.2 kg m -2 , P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  8. The relationships between breast volume, breast dense volume and volumetric breast density with body mass index, body fat mass and ethnicity

    Science.gov (United States)

    Zakariyah, N.; Pathy, N. B.; Taib, N. A. M.; Rahmat, K.; Judy, C. W.; Fadzil, F.; Lau, S.; Ng, K. H.

    2016-03-01

    It has been shown that breast density and obesity are related to breast cancer risk. The aim of this study is to investigate the relationships of breast volume, breast dense volume and volumetric breast density (VBD) with body mass index (BMI) and body fat mass (BFM) for the three ethnic groups (Chinese, Malay and Indian) in Malaysia. We collected raw digital mammograms from 2450 women acquired on three digital mammography systems. The mammograms were analysed using Volpara software to obtain breast volume, breast dense volume and VBD. Body weight, BMI and BFM of the women were measured using a body composition analyser. Multivariable logistic regression was used to determine the independent predictors of increased overall breast volume, breast dense volume and VBD. Indians have highest breast volume and breast dense volume followed by Malays and Chinese. While Chinese are highest in VBD, followed by Malay and Indian. Multivariable analysis showed that increasing BMI and BFM were independent predictors of increased overall breast volume and dense volume. Moreover, BMI and BFM were independently and inversely related to VBD.

  9. Breast density in screening mammography in Indian population - Is it different from western population?

    Science.gov (United States)

    Singh, Tulika; Khandelwal, Niranjan; Singla, Veenu; Kumar, Dileep; Gupta, Madhu; Singh, Gurpreet; Bal, Amanjit

    2018-05-01

    Mammography is the only method presently considered appropriate for mass screening of breast cancer. However, higher breast density was strongly associated with lower mammographic sensitivity. Breast density is also identified as independent and strongest risk factors for breast cancer. Studies have shown women with high breast density have four to six times increased risk of breast cancer as compare to women with fatty breast. It varies between different age group it generally decreases with increasing age in postmenopausal women and it can be different in different ethnic groups and people from different geographical areas. This study evaluates the breast density in Indian population and its relationship with the age. We reviewed of all screening mammography examinations performed from May 2012 to January 2015 at our institute PGIMER, Chandigarh, INDIA. Descriptive analyses were used to examine the association between age and breast density. A total of 6132 screening mammograms were performed. Each subgroup categorized by decade of age. There was a significant inverse relationship between age and breast density (P density in Indian and Western population with more Indians having ACR Grade 1 and 2 and Western population having 2 and 3. We found an inverse relationship between patient age and mammographic breast density. However, there were a large proportion of young women who had lower grades of mammographic density which could potentially benefit from the use of routine screening mammography in this subgroup of patients. Moreover, the breast density of Indian population is less when compared to the Western population. This might suggest that mammography is a good modality of choice for screening Indian population. © 2017 Wiley Periodicals, Inc.

  10. Role of quantitative pharmacokinetic parameter (transfer constant: Ktrans in the characterization of breast lesions on MRI

    Directory of Open Access Journals (Sweden)

    Jena Amarnath

    2013-01-01

    Full Text Available Background: The semi-quantitative analysis of the time-intensity curves in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI has a limited specificity due to overlapping enhancement patterns after gadolinium administration. With the advances in technology and faster sequences, imaging of the entire breast can be done in a few seconds, which allows measuring the transit of contrast (transfer constant: K trans through the vascular bed at capillary level that reflects quantitative measure of porosity/permeability of tumor vessels. Aim: Our study aims to evaluate the pharmacokinetic parameter K trans for enhancing breast lesions and correlate it with histopathology, and assess accuracy, sensitivity, and specificity of this parameter in discriminating benign and malignant breast lesions. Materials and Methods: One hundred and fifty-one women with 216 histologically proved enhancing breast lesions underwent high temporal resolution DCE-MRI for the early dynamic analysis for calculation of pharmacokinetic parameters (K trans using standard two compartment model. The calculated values of K trans were correlated with histopathology to calculate the sensitivity, specificity, and accuracy. Results: Receiver operating characteristic (ROC curve analysis revealed a mean K trans value of 0.56, which reliably distinguished benign and malignant breast lesions with a sensitivity of 91.1% and specificity of 90.3% with an overall accuracy of 89.3%. The area under curve (AUC was 0.907. Conclusion: K trans is a reliable quantitative parameter for characterizing benign and malignant lesions in routine DCE-MRI of breasts.

  11. Comparative utility of MRI perfusion with MSIDR and DWIBS for the characterization of breast tumors

    International Nuclear Information System (INIS)

    Zhang, Bing; Zhu, Bin; Li, Ming

    2012-01-01

    Background. In recent years, breast magnetic resonance imaging (MRI) has been used to evaluate the morphology and functional markers of breast lesions, which might influence local staging and surgical planning. Purpose. To evaluate the feasibility of a one stop MRI protocol combined with diffusion-weighted imaging with background body signal suppression (DWIBS), T2*-weighted perfusion imaging (T2*-PWI) and delayed contrast-enhanced T1-weighted MRI (T1W-C+). Material and Methods. All experiments were conducted with a 3-T clinical MRI scanner. The apparent diffusion coefficient (ADC) and detectability of lesions in DWIBS, the maximal signal intensity drop rate (MSIDR) in T2*-PWI and the intensity increasing rate (IIR) on T1W-C+ were compared between breast malignancies (n = 29) and benign lesions (n = 31). The time-signal curves in the T2*-PWI sequences were classified into two subtypes (a and b) according to the end of the curve. The ADC, MSIDR, the first maximal signal intensity decrease time (MSIDT), and IIR between the malignant and benign lesions were statistically analyzed by unpaired t-tests. Results. Overall, 90% of the lesions were detected by DWIBS. There were significant differences in ADC, MSIDR, and IIR between the carcinomas and benign lesions. The Ib subtype in T2*-PWI demonstrated a specificity of 66.7% in differentiating between carcinomas and benign lesions. At a fixed specificity of 93.5%, the MSIDR, IIR, and ADC differentiated breast carcinomas from benign lesions with sensitivities of 82.8%, 44.8%, and 86.2%, respectively. Conclusion. DWIBS might be a compensation sequence for detecting breast lesions in pre-contrast sequences. MSIDR from T2*-PWI had the best specificity index, and the two subtypes in the T2*-PWI curve were helpful in the differential diagnosis of carcinomas from benign lesions

  12. Value of contrast-enhanced MRI of breast after silicone implant

    International Nuclear Information System (INIS)

    Heinig, A.; Heywang-Koebrunner, S.H.; Viehweg, P.; Spielmann, R.P.; Lampe, D.; Buchmann, J.

    1997-01-01

    Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive calls caused by enhancing granulomas specificity could not be improved. Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI is recommended in patients with diagnostic problems or high risk of recurrence after silicone implants. (orig.) [de

  13. Breast MRI in the Evaluation of Locally Recurrent or New Breast Cancer in the Postoperative Patient: Correlation of Morphology and Enhancement Features with the BI-RADS Category

    International Nuclear Information System (INIS)

    Seely, J.M.; Nguyen, E.T.; Jaffey, J.

    2007-01-01

    Background: While breast magnetic resonance imaging (MRI) is a highly sensitive test for detecting breast carcinoma, its specificity is lower, and several methods have been described on how to optimize specificity. Purpose: To compare the specificity and sensitivity of the BI-RADS category with the Fischer score in breast MRI for diagnosing cancer in women previously treated for breast cancer. Material and Methods: Women referred for evaluation of possible local recurrence or new breast cancer underwent breast MRI examination. Morphologic and kinetic enhancement characteristics were evaluated. BI-RADS category and Fischer score were assigned for each enhancing lesion and compared using a chi-square test. Sensitivity, specificity, and positive predictive values for 27 morphologic and enhancement characteristics were calculated. Pathologic diagnosis was obtained in all patients with enhancing lesions who had ultrasound or mammographic correlation. In those without correlate, 6-, 12-, and 24-month follow-up breast MRIs were obtained. Interobserver kappa correlation was determined for each variable studied. Results: 34 benign and 32 malignant lesions were identified in 26 of 30 patients. BI-RADS category yielded a specificity of 77.1% and a sensitivity of 81.8%. Fischer score had a lower specificity and sensitivity (62.9% and 72.7%, respectively) (P 100% enhancement was more sensitive than BI-RADS for malignant lesions. Specificity was highest for rim enhancement (97.1%), but sensitivity was low (24.2%). Interobserver kappa correlation was good for all 27 characteristics ( = 0.84), and highest for BI-RADS assessment ( 0.91). Conclusion: BI-RADS category in breast MRI had the highest combination of specificity and sensitivity, and the highest interobserver correlation. Fischer score and other morphologic and enhancement features lack sensitivity or specificity and do not have high positive predictive values when analyzed as single independent variables

  14. A fast alignment method for breast MRI follow-up studies using automated breast segmentation and current-prior registration

    Science.gov (United States)

    Wang, Lei; Strehlow, Jan; Rühaak, Jan; Weiler, Florian; Diez, Yago; Gubern-Merida, Albert; Diekmann, Susanne; Laue, Hendrik; Hahn, Horst K.

    2015-03-01

    In breast cancer screening for high-risk women, follow-up magnetic resonance images (MRI) are acquired with a time interval ranging from several months up to a few years. Prior MRI studies may provide additional clinical value when examining the current one and thus have the potential to increase sensitivity and specificity of screening. To build a spatial correlation between suspicious findings in both current and prior studies, a reliable alignment method between follow-up studies is desirable. However, long time interval, different scanners and imaging protocols, and varying breast compression can result in a large deformation, which challenges the registration process. In this work, we present a fast and robust spatial alignment framework, which combines automated breast segmentation and current-prior registration techniques in a multi-level fashion. First, fully automatic breast segmentation is applied to extract the breast masks that are used to obtain an initial affine transform. Then, a non-rigid registration algorithm using normalized gradient fields as similarity measure together with curvature regularization is applied. A total of 29 subjects and 58 breast MR images were collected for performance assessment. To evaluate the global registration accuracy, the volume overlap and boundary surface distance metrics are calculated, resulting in an average Dice Similarity Coefficient (DSC) of 0.96 and root mean square distance (RMSD) of 1.64 mm. In addition, to measure local registration accuracy, for each subject a radiologist annotated 10 pairs of markers in the current and prior studies representing corresponding anatomical locations. The average distance error of marker pairs dropped from 67.37 mm to 10.86 mm after applying registration.

  15. Assessment of three different software systems in the evaluation of dynamic MRI of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, K.D. [Department of Radiology, Stavanger University Hospital, Postbox 8100, Stavanger (Norway)], E-mail: kurk@sus.no; Steinhaus, D. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: Daniele.Steinhaus@med.uni-duesseldorf.de; Klar, V. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: verena.klar@uni-duesseldorf.de; Cohnen, M. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: cohnen@med.uni-duesseldorf.de; Wittsack, H.J. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: wittsack@uni-duesseldorf.de; Saleh, A. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: saleh@uni-duesseldorf.de; Moedder, U. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: moedder@med.uni-duesseldorf.de; Blondin, D. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de

    2009-02-15

    Objective: The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ('CADstream' and '3TP') and one self-developed software system ('Mammatool'). Materials and methods: Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. Results: There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. 'CADstream' showed the best score on subjective quality criteria. '3TP' showed the lowest number of false-positive results. 'Mammatool' produced the lowest number of benign tissues indicated with parametric overlay. Conclusion: All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable.

  16. Ontology based decision system for breast cancer diagnosis

    Science.gov (United States)

    Trabelsi Ben Ameur, Soumaya; Cloppet, Florence; Wendling, Laurent; Sellami, Dorra

    2018-04-01

    In this paper, we focus on analysis and diagnosis of breast masses inspired by expert concepts and rules. Accordingly, a Bag of Words is built based on the ontology of breast cancer diagnosis, accurately described in the Breast Imaging Reporting and Data System. To fill the gap between low level knowledge and expert concepts, a semantic annotation is developed using a machine learning tool. Then, breast masses are classified into benign or malignant according to expert rules implicitly modeled with a set of classifiers (KNN, ANN, SVM and Decision Tree). This semantic context of analysis offers a frame where we can include external factors and other meta-knowledge such as patient risk factors as well as exploiting more than one modality. Based on MRI and DECEDM modalities, our developed system leads a recognition rate of 99.7% with Decision Tree where an improvement of 24.7 % is obtained owing to semantic analysis.

  17. New Embedded Denotes Fuzzy C-Mean Application for Breast Cancer Density Segmentation in Digital Mammograms

    Science.gov (United States)

    Othman, Khairulnizam; Ahmad, Afandi

    2016-11-01

    In this research we explore the application of normalize denoted new techniques in advance fast c-mean in to the problem of finding the segment of different breast tissue regions in mammograms. The goal of the segmentation algorithm is to see if new denotes fuzzy c- mean algorithm could separate different densities for the different breast patterns. The new density segmentation is applied with multi-selection of seeds label to provide the hard constraint, whereas the seeds labels are selected based on user defined. New denotes fuzzy c- mean have been explored on images of various imaging modalities but not on huge format digital mammograms just yet. Therefore, this project is mainly focused on using normalize denoted new techniques employed in fuzzy c-mean to perform segmentation to increase visibility of different breast densities in mammography images. Segmentation of the mammogram into different mammographic densities is useful for risk assessment and quantitative evaluation of density changes. Our proposed methodology for the segmentation of mammograms on the basis of their region into different densities based categories has been tested on MIAS database and Trueta Database.

  18. Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Schilling, Kathy; The, Juliette; Velasquez, Maria Victoria; Kahn, Simone; Saady, Matthew; Mahal, Ravinder; Chrystal, Larraine; Narayanan, Deepa; Kalinyak, Judith E.

    2011-01-01

    The objective of this study was to compare the performance characteristics of 18 F-fluorodeoxyglucose (FDG) positron emission mammography (PEM) with breast magnetic resonance imaging (MRI) as a presurgical imaging and planning option for index and ipsilateral lesions in patients with newly diagnosed, biopsy-proven breast cancer. Two hundred and eight women >25 years of age (median age = 59.7 ± 14.1 years) with biopsy-proven primary breast cancer enrolled in this prospective, single-site study. MRI, PEM, and whole-body positron emission tomography (WBPET) were conducted on each patient within 7 business days. PEM and WBPET images were acquired on the same day after intravenous administration of 370 MBq of FDG (median = 432.9 MBq). PEM and MRI images were blindly evaluated, compared with final surgical histopathology, and the sensitivity determined. Substudy analysis compared the sensitivity of PEM versus MRI in patients with different menopausal status, breast density, and use of hormone replacement therapy (HRT) as well as determination of performance characteristics for additional ipsilateral lesion detection. Two hundred and eight patients enrolled in the study of which 87% (182/208) were analyzable. Of these analyzable patients, 26.4% (48/182), 7.1% (13/182), and 64.2% (120/182) were pre-, peri-, and postmenopausal, respectively, and 48.4% (88/182) had extremely or heterogeneously dense breast tissue, while 33.5% (61/182) had a history of HRT use. Ninety-two percent (167/182) underwent core biopsy for index lesion diagnosis. Invasive cancer was found in 77.5% (141/182), while ductal carcinoma in situ (DCIS) and/or Paget's disease were found in 22.5% (41/182) of patients. Both PEM and MRI had index lesion depiction sensitivity of 92.8% and both were significantly better than WBPET (67.9%, p < 0.001, McNemar's test). For index lesions, PEM and MRI had equivalent sensitivity of various tumors, categorized by tumor stage as well as similar invasive tumor size

  19. Proposed biopsy performance benchmarks for MRI based on an audit of a large academic center.

    Science.gov (United States)

    Sedora Román, Neda I; Mehta, Tejas S; Sharpe, Richard E; Slanetz, Priscilla J; Venkataraman, Shambhavi; Fein-Zachary, Valerie; Dialani, Vandana

    2018-05-01

    Performance benchmarks exist for mammography (MG); however, performance benchmarks for magnetic resonance imaging (MRI) are not yet fully developed. The purpose of our study was to perform an MRI audit based on established MG and screening MRI benchmarks and to review whether these benchmarks can be applied to an MRI practice. An IRB approved retrospective review of breast MRIs was performed at our center from 1/1/2011 through 12/31/13. For patients with biopsy recommendation, core biopsy and surgical pathology results were reviewed. The data were used to derive mean performance parameter values, including abnormal interpretation rate (AIR), positive predictive value (PPV), cancer detection rate (CDR), percentage of minimal cancers and axillary node negative cancers and compared with MG and screening MRI benchmarks. MRIs were also divided by screening and diagnostic indications to assess for differences in performance benchmarks amongst these two groups. Of the 2455 MRIs performed over 3-years, 1563 were performed for screening indications and 892 for diagnostic indications. With the exception of PPV2 for screening breast MRIs from 2011 to 2013, PPVs were met for our screening and diagnostic populations when compared to the MRI screening benchmarks established by the Breast Imaging Reporting and Data System (BI-RADS) 5 Atlas ® . AIR and CDR were lower for screening indications as compared to diagnostic indications. New MRI screening benchmarks can be used for screening MRI audits while the American College of Radiology (ACR) desirable goals for diagnostic MG can be used for diagnostic MRI audits. Our study corroborates established findings regarding differences in AIR and CDR amongst screening versus diagnostic indications. © 2017 Wiley Periodicals, Inc.

  20. Performance comparison of deep learning and segmentation-based radiomic methods in the task of distinguishing benign and malignant breast lesions on DCE-MRI

    Science.gov (United States)

    Antropova, Natasha; Huynh, Benjamin; Giger, Maryellen

    2017-03-01

    Intuitive segmentation-based CADx/radiomic features, calculated from the lesion segmentations of dynamic contrast-enhanced magnetic resonance images (DCE-MRIs) have been utilized in the task of distinguishing between malignant and benign lesions. Additionally, transfer learning with pre-trained deep convolutional neural networks (CNNs) allows for an alternative method of radiomics extraction, where the features are derived directly from the image data. However, the comparison of computer-extracted segmentation-based and CNN features in MRI breast lesion characterization has not yet been conducted. In our study, we used a DCE-MRI database of 640 breast cases - 191 benign and 449 malignant. Thirty-eight segmentation-based features were extracted automatically using our quantitative radiomics workstation. Also, 2D ROIs were selected around each lesion on the DCE-MRIs and directly input into a pre-trained CNN AlexNet, yielding CNN features. Each method was investigated separately and in combination in terms of performance in the task of distinguishing between benign and malignant lesions. Area under the ROC curve (AUC) served as the figure of merit. Both methods yielded promising classification performance with round-robin cross-validated AUC values of 0.88 (se =0.01) and 0.76 (se=0.02) for segmentationbased and deep learning methods, respectively. Combination of the two methods enhanced the performance in malignancy assessment resulting in an AUC value of 0.91 (se=0.01), a statistically significant improvement over the performance of the CNN method alone.

  1. Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme

    Energy Technology Data Exchange (ETDEWEB)

    Timmermans, Lore; Bacher, Klaus; Thierens, Hubert [Ghent University, Department of Basic Medical Sciences, QCC-Gent, Ghent (Belgium); Bleyen, Luc; Herck, Koen van [Ghent University, Centrum voor Preventie en Vroegtijdige Opsporing van Kanker, Ghent (Belgium); Lemmens, Kim; Ongeval, Chantal van; Steen, Andre van [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Martens, Patrick [Centrum voor Kankeropsporing, Bruges (Belgium); Brabander, Isabel de [Belgian Cancer Registry, Brussels (Belgium); Goossens, Mathieu [UZ Brussel, Dienst Kankerpreventie, Brussels (Belgium)

    2017-09-15

    To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. (orig.)

  2. Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme

    International Nuclear Information System (INIS)

    Timmermans, Lore; Bacher, Klaus; Thierens, Hubert; Bleyen, Luc; Herck, Koen van; Lemmens, Kim; Ongeval, Chantal van; Steen, Andre van; Martens, Patrick; Brabander, Isabel de; Goossens, Mathieu

    2017-01-01

    To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. (orig.)

  3. Postoperative enhancement on breast MRI: Time course and pattern of changes.

    Science.gov (United States)

    Mahoney, Mary C; Sharda, Radhika G

    2018-04-23

    Expected postoperative enhancement on breast MRI can appear similar to enhancement seen in recurrent or residual malignancy. Our aim was to assess the time course and patterns of enhancement at the surgical site, thereby helping to distinguish between benign and malignant postoperative enhancement. In 200 MRI scans performed in 153 patients after breast conservation treatment, 43 after surgical excision of atypia, and 4 patients after benign excisional biopsy were categorized by postoperative time interval. We defined 4 patterns of morphologic enhancement on MRI: cavity wall/seroma (Pattern I); thin linear (Pattern II); mass (Pattern III); and fat necrosis (Pattern IV). Of 200 MRI scans, 66 (33%) demonstrated enhancement at the surgical site. Enhancement typically decreased through the postoperative follow-up period. Enhancement was observed in 41% (28/68) of cases beyond the 18-month interval but was uncommon after 5 years. Pattern III enhancement was the morphologic pattern seen most commonly with malignancy (5/19 cases, 26%). When associated with delayed washout kinetics, it was even more strongly predictive of malignancy (4/5 cases, 80%). In patients with a history of excisional biopsy and no prior radiation treatment, the percentage of MRI scans showing enhancement was significantly lower than (21% vs 49% with P-value .0027) in patients who had undergone radiation. Enhancement at the surgical site occurred in one-third of cases up to 5 years after surgery, particularly in patients who underwent both radiation and surgery. Mass enhancement, particularly in conjunction with delayed washout kinetics, is most predictive of malignancy and should prompt biopsy or re-excision. © 2018 Wiley Periodicals, Inc.

  4. Comparison of breast percent density estimation from raw versus processed digital mammograms

    Science.gov (United States)

    Li, Diane; Gavenonis, Sara; Conant, Emily; Kontos, Despina

    2011-03-01

    We compared breast percent density (PD%) measures obtained from raw and post-processed digital mammographic (DM) images. Bilateral raw and post-processed medio-lateral oblique (MLO) images from 81 screening studies were retrospectively analyzed. Image acquisition was performed with a GE Healthcare DS full-field DM system. Image post-processing was performed using the PremiumViewTM algorithm (GE Healthcare). Area-based breast PD% was estimated by a radiologist using a semi-automated image thresholding technique (Cumulus, Univ. Toronto). Comparison of breast PD% between raw and post-processed DM images was performed using the Pearson correlation (r), linear regression, and Student's t-test. Intra-reader variability was assessed with a repeat read on the same data-set. Our results show that breast PD% measurements from raw and post-processed DM images have a high correlation (r=0.98, R2=0.95, p<0.001). Paired t-test comparison of breast PD% between the raw and the post-processed images showed a statistically significant difference equal to 1.2% (p = 0.006). Our results suggest that the relatively small magnitude of the absolute difference in PD% between raw and post-processed DM images is unlikely to be clinically significant in breast cancer risk stratification. Therefore, it may be feasible to use post-processed DM images for breast PD% estimation in clinical settings. Since most breast imaging clinics routinely use and store only the post-processed DM images, breast PD% estimation from post-processed data may accelerate the integration of breast density in breast cancer risk assessment models used in clinical practice.

  5. Surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Clare; Boachie, Charles; Fraser, Cynthia; MacLennan, Graeme; Mowatt, Graham; Thomas, Ruth E. [University of Aberdeen, Health Services Research Unit, Aberdeen (United Kingdom); Ragupathy, Senthil Kumar Arcot [NHS Grampian, Radiology Department, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Heys, Steve D. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Division of Applied Medicine, School of Medicine and Dentistry, Aberdeen (United Kingdom); Gilbert, Fiona J. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Aberdeen Biomedical Imaging Centre, Aberdeen (United Kingdom)

    2011-12-15

    To determine the diagnostic accuracy of surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. A systematic review of surveillance mammography compared with ultrasound, magnetic resonance imaging (MRI), specialist-led clinical examination or unstructured primary care follow-up, using histopathological assessment for test positives and follow-up for test negatives as the reference standard. Nine studies met our inclusion criteria. Variations in study comparisons precluded meta-analysis. For routine ipsilateral breast tumour detection, surveillance mammography sensitivity ranged from 64-67% and specificity ranged from 85-97%. For MRI, sensitivity ranged from 86-100% and specificity was 93%. For non-routine ipsilateral breast tumour detection, sensitivity and specificity for surveillance mammography ranged from 50-83% and 57-75% and for MRI 93-100% and 88-96%. For routine metachronous contralateral breast cancer detection, one study reported sensitivity of 67% and specificity of 50% for both surveillance mammography and MRI. Although mammography is associated with high sensitivity and specificity, MRI is the most accurate test for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. Results should be interpreted with caution because of the limited evidence base. (orig.)

  6. Diffusion magnetic resonance imaging of breast lesions: Initial ...

    African Journals Online (AJOL)

    Hebatallah Hassan Mamdouh Hassan

    2013-03-31

    Mar 31, 2013 ... breast cancer.2 Additional lesions seen by MRI that are not visible on ... characterization of lesions as benign or malignant on the basis ... lular density associated with numerous intact cell ..... ence for ADC values between the two MRI devices, the lesions .... Magnetic resonance imaging of brain and spine.

  7. Computerized three-class classification of MRI-based prognostic markers for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bhooshan, Neha; Giger, Maryellen; Edwards, Darrin; Yuan Yading; Jansen, Sanaz; Li Hui; Lan Li; Newstead, Gillian [Department of Radiology, University of Chicago, Chicago, IL 60637 (United States); Sattar, Husain, E-mail: bhooshan@uchicago.edu [Department of Pathology, University of Chicago, Chicago, IL 60637 (United States)

    2011-09-21

    The purpose of this study is to investigate whether computerized analysis using three-class Bayesian artificial neural network (BANN) feature selection and classification can characterize tumor grades (grade 1, grade 2 and grade 3) of breast lesions for prognostic classification on DCE-MRI. A database of 26 IDC grade 1 lesions, 86 IDC grade 2 lesions and 58 IDC grade 3 lesions was collected. The computer automatically segmented the lesions, and kinetic and morphological lesion features were automatically extracted. The discrimination tasks-grade 1 versus grade 3, grade 2 versus grade 3, and grade 1 versus grade 2 lesions-were investigated. Step-wise feature selection was conducted by three-class BANNs. Classification was performed with three-class BANNs using leave-one-lesion-out cross-validation to yield computer-estimated probabilities of being grade 3 lesion, grade 2 lesion and grade 1 lesion. Two-class ROC analysis was used to evaluate the performances. We achieved AUC values of 0.80 {+-} 0.05, 0.78 {+-} 0.05 and 0.62 {+-} 0.05 for grade 1 versus grade 3, grade 1 versus grade 2, and grade 2 versus grade 3, respectively. This study shows the potential for (1) applying three-class BANN feature selection and classification to CADx and (2) expanding the role of DCE-MRI CADx from diagnostic to prognostic classification in distinguishing tumor grades.

  8. Longitudinal MRI evaluation of intracranial development and vascular characteristics of breast cancer brain metastases in a mouse model.

    Directory of Open Access Journals (Sweden)

    Heling Zhou

    Full Text Available Longitudinal MRI was applied to monitor intracranial initiation and development of brain metastases and assess tumor vascular volume and permeability in a mouse model of breast cancer brain metastases. Using a 9.4T system, high resolution anatomic MRI and dynamic susceptibility contrast (DSC perfusion MRI were acquired at different time points after an intracardiac injection of brain-tropic breast cancer MDA-MB231BR-EGFP cells. Three weeks post injection, multifocal brain metastases were first observed with hyperintensity on T2-weighted images, but isointensity on T1-weighted post contrast images, indicating that blood-tumor-barrier (BTB at early stage of brain metastases was impermeable. Follow-up MRI revealed intracranial tumor growth and increased number of metastases that distributed throughout the whole brain. At the last scan on week 5, T1-weighted post contrast images detected BTB disruption in 160 (34% of a total of 464 brain metastases. Enhancement in some of the metastases was only seen in partial regions of the tumor, suggesting intratumoral heterogeneity of BTB disruption. DSC MRI measurements of relative cerebral blood volume (rCBV showed that rCBV of brain metastases was significantly lower (mean= 0.89±0.03 than that of contralateral normal brain (mean= 1.00±0.03; p<0.005. Intriguingly, longitudinal measurements revealed that rCBV of individual metastases at early stage was similar to, but became significantly lower than that of contralateral normal brain with tumor growth (p<0.05. The rCBV data were concordant with histological analysis of microvascular density (MVD. Moreover, comprehensive analysis suggested no significant correlation among tumor size, rCBV and BTB permeability. In conclusion, longitudinal MRI provides non-invasive in vivo assessments of spatial and temporal development of brain metastases and their vascular volume and permeability. The characteristic rCBV of brain metastases may have a diagnostic value.

  9. Breast MRI background parenchymal enhancement (BPE) correlates with the risk of breast cancer.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2016-02-01

    To investigate whether background parenchymal enhancement (BPE) and breast cancer would correlate searching for any significant difference of BPE pattern distribution in case of benign or malignant lesions. 386 patients, including 180 pre-menopausal (group 1) and 206 post-menopausal (group 2), underwent MR examination. Two radiologists evaluated MR images classifying normal BPE as minimal, mild, moderate or marked. The two groups of patients were subdivided into 3 categories based on MRI findings (negative, benign and malignant lesions). The distribution of BPE patterns within the two groups and within the three MR categories was calculated. The χ2 test was used to evaluate BPE type distribution in the three patient categories and any statistically significant correlation of BPE with lesion type was calculated. The Student t test was applied to search for any statistically significant difference between BPE type rates in group 1 and 2. The χ2 test demonstrated a statistically significant difference in the distribution of BPE types in negative patients and benign lesions as compared with malignant ones (p0.05). Normal BPE could correlate with the risk of breast cancer being such BPE patterns as moderate and marked associated with patients with malignant lesions in both pre and post-menopausal women. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The combined effect of mammographic texture and density on breast cancer risk: a cohort study.

    Science.gov (United States)

    Wanders, Johanna O P; van Gils, Carla H; Karssemeijer, Nico; Holland, Katharina; Kallenberg, Michiel; Peeters, Petra H M; Nielsen, Mads; Lillholm, Martin

    2018-05-02

    Texture patterns have been shown to improve breast cancer risk segregation in addition to area-based mammographic density. The additional value of texture pattern scores on top of volumetric mammographic density measures in a large screening cohort has never been studied. Volumetric mammographic density and texture pattern scores were assessed automatically for the first available digital mammography (DM) screening examination of 51,400 women (50-75 years of age) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. The texture assessment method was developed in a previous study and validated in the current study. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. All screen-detected breast cancers diagnosed at the first available digital screening examination were excluded. During a median follow-up period of 4.2 (interquartile range (IQR) 2.0-6.2) years, 301 women were diagnosed with breast cancer. The associations between texture pattern scores, volumetric breast density measures and breast cancer risk were determined using Cox proportional hazard analyses. Discriminatory performance was assessed using c-indices. The median age of the women at the time of the first available digital mammography examination was 56 years (IQR 51-63). Texture pattern scores were positively associated with breast cancer risk (hazard ratio (HR) 3.16 (95% CI 2.16-4.62) (p value for trend <0.001), for quartile (Q) 4 compared to Q1). The c-index of texture was 0.61 (95% CI 0.57-0.64). Dense volume and percentage dense volume showed positive associations with breast cancer risk (HR 1.85 (95% CI 1.32-2.59) (p value for trend <0.001) and HR 2.17 (95% CI 1.51-3.12) (p value for trend <0.001), respectively, for Q4 compared to Q1). When adding texture measures to models with dense volume or percentage dense volume, c-indices increased from 0.56 (95% CI 0.53-0.59) to 0

  11. TU-AB-201-11: A Novel Theoretical Framework for MRI-Only Image Guided LDR Prostate and Breast Brachytherapy Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, A; Elzibak, A; Fatemi, A; Safigholi, H; Ravi, A; Morton, G; Song, W [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Han, D [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: To propose a novel framework for accurate model-based dose calculations using only MR images for LDR prostate and breast seed implant brachytherapy. Methods: Model-based dose calculation methodologies recommended by TG-186 require further knowledge about specific tissue composition, which is challenging with MRI. However, relying on MRI-only for implant dosimetry would reduce the soft tissue delineation uncertainty, costs, and uncertainties associated with multi-modality registration and fusion processes. We propose a novel framework to address this problem using quantitative MRI acquisitions and reconstruction techniques. The framework includes three steps: (1) Identify the locations of seeds(2) Identify the presence (or absence) of calcification(s)(3) Quantify the water and fat content in the underlying tissueSteps (1) and (2) consider the sources that limit patient dosimetry, particularly the inter-seed attenuation and the calcified regions; while step (3) targets the quantification of the tissue composition to consider the heterogeneities in the medium. Our preliminary work has shown that the seeds and the calcifications can be identified with MRI using both the magnitude and the phase images. By employing susceptibility-weighted imaging with specific post-processing techniques, the phase images can be further explored to distinguish the seeds from the calcifications. Absolute quantification of tissue, water, and fat content is feasible and was previously demonstrated in phantoms and in-vivo applications, particularly for brain diseases. The approach relies on the proportionality of the MR signal to the number of protons in an image volume. By employing appropriate correction algorithms for T1 - and T2*-related biases, B1 transmit and receive field inhomogeneities, absolute water/fat content can be determined. Results: By considering calcification and interseed attenuation, and through the knowledge of water and fat mass density, accurate patient

  12. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  13. Classification System for Identifying Women at Risk for Altered Partial Breast Irradiation Recommendations After Breast Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Kowalchik, Kristin V.; Vallow, Laura A.; McDonough, Michelle; Thomas, Colleen S.; Heckman, Michael G.; Peterson, Jennifer L.; Adkisson, Cameron D.; Serago, Christopher; McLaughlin, Sarah A.

    2013-01-01

    Purpose: To study the utility of preoperative breast MRI for partial breast irradiation (PBI) patient selection, using multivariable analysis of significant risk factors to create a classification rule. Methods and Materials: Between 2002 and 2009, 712 women with newly diagnosed breast cancer underwent preoperative bilateral breast MRI at Mayo Clinic Florida. Of this cohort, 566 were retrospectively deemed eligible for PBI according to the National Surgical Adjuvant Breast and Bowel Project Protocol B-39 inclusion criteria using physical examination, mammogram, and/or ultrasound. Magnetic resonance images were then reviewed to determine their impact on patient eligibility. The patient and tumor characteristics were evaluated to determine risk factors for altered PBI eligibility after MRI and to create a classification rule. Results: Of the 566 patients initially eligible for PBI, 141 (25%) were found ineligible because of pathologically proven MRI findings. Magnetic resonance imaging detected additional ipsilateral breast cancer in 118 (21%). Of these, 62 (11%) had more extensive disease than originally noted before MRI, and 64 (11%) had multicentric disease. Contralateral breast cancer was detected in 28 (5%). Four characteristics were found to be significantly associated with PBI ineligibility after MRI on multivariable analysis: premenopausal status (P=.021), detection by palpation (P<.001), first-degree relative with a history of breast cancer (P=.033), and lobular histology (P=.002). Risk factors were assigned a score of 0-2. The risk of altered PBI eligibility from MRI based on number of risk factors was 0:18%; 1:22%; 2:42%; 3:65%. Conclusions: Preoperative bilateral breast MRI altered the PBI recommendations for 25% of women. Women who may undergo PBI should be considered for breast MRI, especially those with lobular histology or with 2 or more of the following risk factors: premenopausal, detection by palpation, and first-degree relative with a history of

  14. Dense breasts: a review of reporting legislation and available supplemental screening options.

    Science.gov (United States)

    Ho, Jessica M; Jafferjee, Nasima; Covarrubias, Gabriel M; Ghesani, Munir; Handler, Bradley

    2014-08-01

    The objectives of this article are to discuss the Mammography Quality Standards Act (MQSA) and what it means for patients, define breast density and explain how it is measured, review the new state-based legislation regarding the reporting of dense breast tissue directly to patients and the possibility of an adjunct screening examination, describe possible supplemental screening options and the advantages and disadvantages of each, and outline the current shortcomings and unanswered questions regarding new legislation. Breast density is now established as an independent risk factor for developing breast cancer irrespective of other known risk factors. Women with breast density in the upper quartile have an associated four to five times greater risk of developing breast cancer relative to women with breast density in the lower quartile. Many states have enacted or proposed legislation requiring mammographers to report to patients directly if they have dense breast tissue and recommend discussing the possibility of a supplemental screening examination with their physicians. However, there is currently no consensus as to whether a supplemental screening examination should be pursued or which modality to use. Possible supplemental screening modalities include ultrasound, MRI, digital breast tomosynthesis, and molecular breast imaging. The U.S. Food and Drug Administration recently approved an automated breast ultrasound system for screening whole-breast ultrasound in patients with dense breasts. However, many questions are still unanswered including the impact on morbidity and mortality, cost-effectiveness, and insurance coverage.

  15. Investigation of mammographic breast density as a risk factor for ovarian cancer.

    Science.gov (United States)

    Wernli, Karen J; O'Meara, Ellen S; Kerlikowske, Karla; Miglioretti, Diana L; Muller, Carolyn Y; Onega, Tracy; Sprague, Brian L; Henderson, Louise M; Buist, Diana S M

    2014-01-01

    Endogenous hormones and growth factors that increase mammographic breast density could increase ovarian cancer risk. We examined whether high breast density is associated with ovarian cancer risk. We conducted a cohort study of 724,603 women aged 40 to 79 years with 2,506,732 mammograms participating in the Breast Cancer Surveillance Consortium from 1995 to 2009. Incident epithelial ovarian cancer was diagnosed in 1373 women. We used partly conditional Cox regression to estimate the association between breast density and 5-year risk of incident epithelial ovarian cancer overall and stratified by 10-year age group. All statistical tests were two-sided. Compared with women with scattered fibroglandular densities, women with heterogeneously dense and extremely dense breast tissue had 20% and 18% increased 5-year risk of incident epithelial ovarian cancer (hazard ratio [HR] = 1.20, 95% confidence interval [CI] = 1.06 to 1.36; HR = 1.18, 95% CI = 0.93 to 1.50, respectively; P(trend) = .01). Among women aged 50 to 59 years, we observed a trend in elevated risk associated with increased breast density (P(trend) = .02); women with heterogeneously and extremely dense breast tissue had 30% (HR = 1.30; 95% CI = 1.03 to 1.64) and 65% (HR = 1.65; 95% CI = 1.12 to 2.44) increased risk, respectively, compared with women with scattered fibroglandular densities. The pattern was similar but not statistically significant at age 40 to 49 years. There were no consistent patterns of breast density and ovarian cancer risk at age 60 to 79 years. Dense breast tissue was associated with a modest increase in 5-year ovarian cancer risk in women aged 50 to 59 years but was not associated with ovarian cancer at ages 40 to 49 or 60 to 79 years.

  16. Usefulness of preoperative chest multidetector CT for evaluation of breast cancer: comparison with breast MRI

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Kim, Dong Hun; Lee, Min Hyuk

    2005-01-01

    To evaluate the efficacy of chest multidetector-row helical computed tomography (MDCT) in detecting breast cancer in preoperative metastasis work-ups and to assess the accuracy of MDCT compared with magnetic resonance imaging (MRI). MDCT were performed on 69 consecutive patients with 94 lesions of histologically proven breast cancer. Retrospectively, two radiologists performed a blind review of the MDCT images for margin, shape, mass enhancement pattern and the enhancing distribution of non-mass lesions with consensus. CT attenuation values were measured in the average HU on pre-enhancing and enhanced CT in gland, fat, muscle, and in masses with the largest region of interest (ROI). MDCT finding were analyzed and compared with breast MRI. Of the 91 breast lesions detected on MDCT, 64 were mass lesions and 24 were non-mass lesions on enhancement, 86 lesions were malignant and 5 were benign. Three pathologically proven malignant masses were not detected on MDCT. Positive predictive value, false positive rate and false negative rate were 94.5%, 5.3%, 3.2% respectively. The highly predictive features for malignancy were a spiculated or irregular margin, an irregular of round shape, and a heterogeneously or rim enhanced mass. Another highly predictive feature for malignancy was linear or segmentally distributed enhancing non-mass lesions. The CT values of masses in pre-enhanced scans were 38.6 ± 7.9 HU; these values increased to 110.9 ± 26.6 HU after contrast injection (90 sec). The attenuation values from enhancing CT of malignant lesions were significantly higher than those of non-enhancing lesions. The depiction of enhancing masses on MDCT compared with MR imaging were 88.6%. The extension of malignancy were equally well correlated MDCT with MR imaging. The diagnostic value of chest MDCT for preoperative staging is comparable with MR imaging for the detection and extension of lesions. Therefore, chest MDCT of breast cancer can add to the information obtained from

  17. Quantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2017-01-01

    Full Text Available Purpose. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI of the breast. Methods. We considered five ubiquitous temporal regularizers on 4.5x retrospectively undersampled Cartesian in vivo breast DCE-MRI data: Fourier transform (FT, Haar wavelet transform (WT, total variation (TV, second-order total generalized variation (TGVα2, and nuclear norm (NN. We measured the signal-to-error ratio (SER of the reconstructed images, the error in tumor mean, and concordance correlation coefficients (CCCs of the derived pharmacokinetic parameters Ktrans (volume transfer constant and ve (extravascular-extracellular volume fraction across a population of random sampling schemes. Results. NN produced the lowest image error (SER: 29.1, while TV/TGVα2 produced the most accurate Ktrans (CCC: 0.974/0.974 and ve (CCC: 0.916/0.917. WT produced the highest image error (SER: 21.8, while FT produced the least accurate Ktrans (CCC: 0.842 and ve (CCC: 0.799. Conclusion. TV/TGVα2 should be used as temporal constraints for CS DCE-MRI of the breast.

  18. Comparison of pharmacokinetic MRI and [{sup 18}F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Henze, M. [Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany); Knopp, M.V.; Doll, J.; Hawighorst, H. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Lucht, R. [Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Junkermann, H. [Dept. of Gynaecological Radiology, Univ. of Heidelberg (Germany); Haberkorn, U. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany)

    2001-10-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  19. Cumulative sum quality control for calibrated breast density measurements

    International Nuclear Information System (INIS)

    Heine, John J.; Cao Ke; Beam, Craig

    2009-01-01

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  20. Cumulative sum quality control for calibrated breast density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

    2009-12-15

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  1. Effect of Imaging Parameter Thresholds on MRI Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer Subtypes.

    Directory of Open Access Journals (Sweden)

    Wei-Ching Lo

    Full Text Available The purpose of this study is to evaluate the predictive performance of magnetic resonance imaging (MRI markers in breast cancer patients by subtype. Sixty-four patients with locally advanced breast cancer undergoing neoadjuvant chemotherapy were enrolled in this study. Each patient received a dynamic contrast-enhanced (DCE-MRI at baseline, after 1 cycle of chemotherapy and before surgery. Functional tumor volume (FTV, the imaging marker measured by DCE-MRI, was computed at various thresholds of percent enhancement (PEt and signal-enhancement ratio (SERt. Final FTV before surgery and percent changes of FTVs at the early and final treatment time points were used to predict patients' recurrence-free survival. The full cohort and each subtype defined by the status of hormone receptor and human epidermal growth factor receptor 2 (HR+/HER2-, HER2+, triple negative were analyzed. Predictions were evaluated using the Cox proportional hazard model when PEt changed from 30% to 200% in steps of 10% and SERt changed from 0 to 2 in steps of 0.2. Predictions with high hazard ratios and low p-values were considered as strong. Different profiles of FTV as predictors for recurrence-free survival were observed in each breast cancer subtype and strong associations with survival were observed at different PEt/SERt combinations that resulted in different FTVs. Findings from this retrospective study suggest that the predictive performance of imaging markers based on FTV may be improved with enhancement thresholds being optimized separately for clinically-relevant subtypes defined by HR and HER2 receptor expression.

  2. Development of a sampling strategy and sample size calculation to estimate the distribution of mammographic breast density in Korean women.

    Science.gov (United States)

    Jun, Jae Kwan; Kim, Mi Jin; Choi, Kui Son; Suh, Mina; Jung, Kyu-Won

    2012-01-01

    Mammographic breast density is a known risk factor for breast cancer. To conduct a survey to estimate the distribution of mammographic breast density in Korean women, appropriate sampling strategies for representative and efficient sampling design were evaluated through simulation. Using the target population from the National Cancer Screening Programme (NCSP) for breast cancer in 2009, we verified the distribution estimate by repeating the simulation 1,000 times using stratified random sampling to investigate the distribution of breast density of 1,340,362 women. According to the simulation results, using a sampling design stratifying the nation into three groups (metropolitan, urban, and rural), with a total sample size of 4,000, we estimated the distribution of breast density in Korean women at a level of 0.01% tolerance. Based on the results of our study, a nationwide survey for estimating the distribution of mammographic breast density among Korean women can be conducted efficiently.

  3. SU-G-JeP2-02: A Unifying Multi-Atlas Approach to Electron Density Mapping Using Multi-Parametric MRI for Radiation Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Ren, S [Stanford University, Stanford, CA (United States); Tianjin University, Tianjin (China); Hara, W; Le, Q; Wang, L; Xing, L; Li, R [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: MRI has a number of advantages over CT as a primary modality for radiation treatment planning (RTP). However, one key bottleneck problem still remains, which is the lack of electron density information in MRI. In the work, a reliable method to map electron density is developed by leveraging the differential contrast of multi-parametric MRI. Methods: We propose a probabilistic Bayesian approach for electron density mapping based on T1 and T2-weighted MRI, using multiple patients as atlases. For each voxel, we compute two conditional probabilities: (1) electron density given its image intensity on T1 and T2-weighted MR images, and (2) electron density given its geometric location in a reference anatomy. The two sources of information (image intensity and spatial location) are combined into a unifying posterior probability density function using the Bayesian formalism. The mean value of the posterior probability density function provides the estimated electron density. Results: We evaluated the method on 10 head and neck patients and performed leave-one-out cross validation (9 patients as atlases and remaining 1 as test). The proposed method significantly reduced the errors in electron density estimation, with a mean absolute HU error of 138, compared with 193 for the T1-weighted intensity approach and 261 without density correction. For bone detection (HU>200), the proposed method had an accuracy of 84% and a sensitivity of 73% at specificity of 90% (AUC = 87%). In comparison, the AUC for bone detection is 73% and 50% using the intensity approach and without density correction, respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection based on multi-parametric MRI of the head with highly heterogeneous anatomy. This could allow for accurate dose calculation and reference image generation for patient setup in MRI-based radiation treatment planning.

  4. SU-G-JeP2-02: A Unifying Multi-Atlas Approach to Electron Density Mapping Using Multi-Parametric MRI for Radiation Treatment Planning

    International Nuclear Information System (INIS)

    Ren, S; Hara, W; Le, Q; Wang, L; Xing, L; Li, R

    2016-01-01

    Purpose: MRI has a number of advantages over CT as a primary modality for radiation treatment planning (RTP). However, one key bottleneck problem still remains, which is the lack of electron density information in MRI. In the work, a reliable method to map electron density is developed by leveraging the differential contrast of multi-parametric MRI. Methods: We propose a probabilistic Bayesian approach for electron density mapping based on T1 and T2-weighted MRI, using multiple patients as atlases. For each voxel, we compute two conditional probabilities: (1) electron density given its image intensity on T1 and T2-weighted MR images, and (2) electron density given its geometric location in a reference anatomy. The two sources of information (image intensity and spatial location) are combined into a unifying posterior probability density function using the Bayesian formalism. The mean value of the posterior probability density function provides the estimated electron density. Results: We evaluated the method on 10 head and neck patients and performed leave-one-out cross validation (9 patients as atlases and remaining 1 as test). The proposed method significantly reduced the errors in electron density estimation, with a mean absolute HU error of 138, compared with 193 for the T1-weighted intensity approach and 261 without density correction. For bone detection (HU>200), the proposed method had an accuracy of 84% and a sensitivity of 73% at specificity of 90% (AUC = 87%). In comparison, the AUC for bone detection is 73% and 50% using the intensity approach and without density correction, respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection based on multi-parametric MRI of the head with highly heterogeneous anatomy. This could allow for accurate dose calculation and reference image generation for patient setup in MRI-based radiation treatment planning.

  5. Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI.

    Science.gov (United States)

    Ferradal, Silvina L; Eggebrecht, Adam T; Hassanpour, Mahlega; Snyder, Abraham Z; Culver, Joseph P

    2014-01-15

    Diffuse optical imaging (DOI) is increasingly becoming a valuable neuroimaging tool when fMRI is precluded. Recent developments in high-density diffuse optical tomography (HD-DOT) overcome previous limitations of sparse DOI systems, providing improved image quality and brain specificity. These improvements in instrumentation prompt the need for advancements in both i) realistic forward light modeling for accurate HD-DOT image reconstruction, and ii) spatial normalization for voxel-wise comparisons across subjects. Individualized forward light models derived from subject-specific anatomical images provide the optimal inverse solutions, but such modeling may not be feasible in all situations. In the absence of subject-specific anatomical images, atlas-based head models registered to the subject's head using cranial fiducials provide an alternative solution. In addition, a standard atlas is attractive because it defines a common coordinate space in which to compare results across subjects. The question therefore arises as to whether atlas-based forward light modeling ensures adequate HD-DOT image quality at the individual and group level. Herein, we demonstrate the feasibility of using atlas-based forward light modeling and spatial normalization methods. Both techniques are validated using subject-matched HD-DOT and fMRI data sets for visual evoked responses measured in five healthy adult subjects. HD-DOT reconstructions obtained with the registered atlas anatomy (i.e. atlas DOT) had an average localization error of 2.7mm relative to reconstructions obtained with the subject-specific anatomical images (i.e. subject-MRI DOT), and 6.6mm relative to fMRI data. At the group level, the localization error of atlas DOT reconstruction was 4.2mm relative to subject-MRI DOT reconstruction, and 6.1mm relative to fMRI. These results show that atlas-based image reconstruction provides a viable approach to individual head modeling for HD-DOT when anatomical imaging is not available

  6. Application of whole-lesion histogram analysis of pharmacokinetic parameters in dynamic contrast-enhanced MRI of breast lesions with the CAIPIRINHA-Dixon-TWIST-VIBE technique.

    Science.gov (United States)

    Li, Zhiwei; Ai, Tao; Hu, Yiqi; Yan, Xu; Nickel, Marcel Dominik; Xu, Xiao; Xia, Liming

    2018-01-01

    To investigate the application of whole-lesion histogram analysis of pharmacokinetic parameters for differentiating malignant from benign breast lesions on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In all, 92 women with 97 breast lesions (26 benign and 71 malignant lesions) were enrolled in this study. Patients underwent dynamic breast MRI at 3T using a prototypical CAIPIRINHA-Dixon-TWIST-VIBE (CDT-VIBE) sequence and a subsequent surgery or biopsy. Inflow rate of the agent between plasma and interstitium (K trans ), outflow rate of agent between interstitium and plasma (K ep ), extravascular space volume per unit volume of tissue (v e ) including mean value, 25th/50th/75th/90th percentiles, skewness, and kurtosis were then calculated based on the whole lesion. A single-sample Kolmogorov-Smirnov test, paired t-test, and receiver operating characteristic curve (ROC) analysis were used for statistical analysis. Malignant breast lesions had significantly higher K trans , K ep , and lower v e in mean values, 25th/50th/75th/90th percentiles, and significantly higher skewness of v e than benign breast lesions (all P 0.05). The 90th percentile of K trans , the 90th percentile of K ep , and the 50th percentile of v e showed the greatest areas under the ROC curve (AUC) for each pharmacokinetic parameter derived from DCE-MRI. The 90th percentile of K ep achieved the highest AUC value (0.927) among all histogram-derived values. The whole-lesion histogram analysis of pharmacokinetic parameters can improve the diagnostic accuracy of breast DCE-MRI with the CDT-VIBE technique. The 90th percentile of K ep may be the best indicator in differentiation between malignant and benign breast lesions. 4 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2018;47:91-96. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Role of magnetic resonance imaging (MRI), MR spectroscopy (MRS) and other imaging modalities in breast cancer

    International Nuclear Information System (INIS)

    Sharma, Uma; Virendra Kumar; Jagannathan, N.R.

    2004-01-01

    Breast cancer is the commonest cancer among women world over and the diagnosis continues to generate fear and turmoil in the life of patients and their families. This article describes the currently available techniques used for screening primary and recurrent breast cancers and the evaluation of therapeutic response of breast cancer with special emphasis on MRI and MRS techniques. MRI, a noninvasive technique, provides anatomic images in multiple planes enabling tissue characterization. Contrast enhanced MR studies have been found to be useful in the diagnosis of small tumors in dense breast benign diseases from malignant ones. In vivo magnetic resonance spectroscopy (MRS) is another useful technique for diagnosis and for assessing the biochemical status of normal and diseased tissues. Being noninvasive, MR techniques can be used repetitively for assessment of response of the tumor to various therapeutic regimens and for evaluating the efficacy of drugs at both the structural and molecular level. An overview of the various aspects of different imaging modalities used in breast cancer research including various in vivo MR methodologies with clinical examples is presented in this review. (author)

  8. MRI of the breast with 2D spin-echo and gradient echo sequences in diagnostically difficult cases

    International Nuclear Information System (INIS)

    Allgayer, B.; Lukas, P.; Loos, W.; Kersting-Sommerhoff, B.

    1993-01-01

    One or both breasts of 296 patients with equivocal clinical or mammographical findings were examined with MRI. T 1 weighted spinecho (SE) and gradient echo (FFE) sequences were acquired before and after i.v. application of Gadolinium DTPA. 50 lesions with enhancement after Gd-DTPA were biopsied -26 carcinomas, 17 proliferating mastopathic tissues, 5 fibroadenomas and 1 abscess were found. Contrast enhanced MRI with 2D-SE and FFE sequences is an effective technqiue for evaluating suspicious breast lesions with high diagnostic acurracy. (orig.) [de

  9. Indications for MRI of the breast - current status. Pt. 1

    International Nuclear Information System (INIS)

    Rieber, A.; Tomczak, R.; Nuessle, K.; Brambs, H.J.

    1997-01-01

    Since MRI is being applied as a diagnostic imaging method, there is no other field of application of MRI that has been causing debates and emotions of such controversial nature as has MRI of the breast. Advocates of the method emphasize the fact that MR mammography is capable of detecting carcinomas not shown by all other available methods, and diagnostic findings even permit identification of malignomas with a high accuracy. As a concluding statement of the analysis of the pros and cons it can be said that establishment of a routine diagnostic method offering higher sensitivity and specificity than other available methods, free of radiological risks at that, certainly would be appropriate. Those supporting MR mammography believe that this method is up to all requirements stated. However, financial constraints in the public health sector demand that the range of indications be well defined. (orig./AJ) [de

  10. First pregnancy characteristics, postmenopausal breast density, and salivary sex hormone levels in a population at high risk for breast cancer

    Directory of Open Access Journals (Sweden)

    Mary Mockus

    2015-06-01

    Conclusions and general significance: While reproductive characteristics, in particular parity, generally demonstrated independent associations with postmenopausal breast density and E, P and DHEA levels, T levels showed concordant inverse associations with age-at-first birth and breast density. These findings suggest that reproductive effects and later life salivary sex steroid hormone levels may have independent effects on later life breast density and cancer risk.

  11. Minimal impact of adjuvant exemestane or tamoxifen treatment on mammographic breast density in postmenopausal breast cancer patients: A Dutch TEAM trial analysis

    NARCIS (Netherlands)

    J.G.H. van Nes; L.V. Beex (Louk); C.M. Seynaeve (Caroline); H. Putter (Hein); A. Sramek (Alexandr); S. Lardenoije (Susanne); M.D.-D.E. Carpentier (Marjolijn Duijm-D.E.); I. Van Rongen (Inge); J.W.R. Nortier (Johan W. R.); H.M. Zonderland (Harmine); C.J.H. van de Velde (Cornelis)

    2015-01-01

    textabstractBackground. Mammographic breast density is one of the strongest independent risk factors for developing breast cancer. We examined the effect of exemestane and tamoxifen on breast density in Dutch postmenopausal early breast cancer patients participating in the Tamoxifen Exemestane

  12. A modified Seeded Region Growing algorithm for vessel segmentation in breast MRI images for investigating the nature of potential lesions

    Science.gov (United States)

    Glotsos, D.; Vassiou, K.; Kostopoulos, S.; Lavdas, El; Kalatzis, I.; Asvestas, P.; Arvanitis, D. L.; Fezoulidis, I. V.; Cavouras, D.

    2014-03-01

    The role of Magnetic Resonance Imaging (MRI) as an alternative protocol for screening of breast cancer has been intensively investigated during the past decade. Preliminary research results have indicated that gadolinium-agent administrative MRI scans may reveal the nature of breast lesions by analyzing the contrast-agent's uptake time. In this study, we attempt to deduce the same conclusion, however, from a different perspective by investigating, using image processing, the vascular network of the breast at two different time intervals following the administration of gadolinium. Twenty cases obtained from a 3.0-T MRI system (SIGNA HDx; GE Healthcare) were included in the study. A new modification of the Seeded Region Growing (SRG) algorithm was used to segment vessels from surrounding background. Delineated vessels were investigated by means of their topology, morphology and texture. Results have shown that it is possible to estimate the nature of the lesions with approximately 94.4% accuracy, thus, it may be claimed that the breast vascular network does encodes useful, patterned, information, which can be used for characterizing breast lesions.

  13. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Centre, Institute of Radiation Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of)

    2017-12-15

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  14. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI

    International Nuclear Information System (INIS)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-01-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. (orig.)

  15. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  16. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  17. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Breast cancer Ki67 expression preoperative discrimination by DCE-MRI radiomics features

    Science.gov (United States)

    Ma, Wenjuan; Ji, Yu; Qin, Zhuanping; Guo, Xinpeng; Jian, Xiqi; Liu, Peifang

    2018-02-01

    To investigate whether quantitative radiomics features extracted from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) are associated with Ki67 expression of breast cancer. In this institutional review board approved retrospective study, we collected 377 cases Chinese women who were diagnosed with invasive breast cancer in 2015. This cohort included 53 low-Ki67 expression (Ki67 proliferation index less than 14%) and 324 cases with high-Ki67 expression (Ki67 proliferation index more than 14%). A binary-classification of low- vs. high- Ki67 expression was performed. A set of 52 quantitative radiomics features, including morphological, gray scale statistic, and texture features, were extracted from the segmented lesion area. Three most common machine learning classification methods, including Naive Bayes, k-Nearest Neighbor and support vector machine with Gaussian kernel, were employed for the classification and the least absolute shrink age and selection operator (LASSO) method was used to select most predictive features set for the classifiers. Classification performance was evaluated by the area under receiver operating characteristic curve (AUC), accuracy, sensitivity and specificity. The model that used Naive Bayes classification method achieved the best performance than the other two methods, yielding 0.773 AUC value, 0.757 accuracy, 0.777 sensitivity and 0.769 specificity. Our study showed that quantitative radiomics imaging features of breast tumor extracted from DCE-MRI are associated with breast cancer Ki67 expression. Future larger studies are needed in order to further evaluate the findings.

  19. Controlling the Stormram 2: An MRI-compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Abdelaziz, Mohamed E.M.K.; Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Breast cancer is the most frequently life-threatening diagnosed type of cancer among women. Early and accurate diagnosis by acquiring a tissue sample using biopsy techniques is essential. However, small lesions only visible by MRI are often missed in standard methods, indicating the need for a

  20. Background parenchymal enhancement in breast MRI before and after neoadjuvant chemotherapy: correlation with tumour response

    Energy Technology Data Exchange (ETDEWEB)

    Preibsch, H.; Wanner, L.; Bahrs, S.D.; Wietek, B.M.; Nikolaou, K.; Wiesinger, B. [University Hospital Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany); Siegmann-Luz, K.C. [Diagnostic Center for Breast Cancer and Screening Mammography Brandenburg Ost, Koenigs Wusterhausen (Germany); Oberlecher, E.; Hahn, M. [University Hospital Tuebingen, Department of Gynecology and Obstetrics, Tuebingen (Germany); Staebler, A. [University Hospital Tuebingen, Institute of Pathology and Neuropathology, Tuebingen (Germany)

    2016-06-15

    To correlate the decrease in background parenchymal enhancement (BPE) and tumour response measured with MRI in breast cancer patients treated with neoadjuvant chemotherapy (NAC). One hundred and forty-six MRI examinations of 73 patients with 80 biopsy-proven breast cancers who underwent breast MRI before and after NAC were retrospectively analysed. All images were reviewed by two blinded readers, who classified BPE into categories (BEC; 1 = minimal, 2 = mild, 3 = moderate, 4 = marked) before and after NAC. Histopathological and morphological tumour responses were analysed and compared. The distribution of BEC 1/2/3/4 was 25/46/18/11 % before and 78/20/2/0 % after NAC. On average, BPE decreased by 0.87 BEC. Cohen's kappa showed substantial agreement (k = 0.73-0.77) before and moderate agreement (k = 0.43-0.60) after NAC and moderate agreement (k = 0.62-0.60) concerning the change in BEC. Correlating the change in BPE with tumour response, the average decrease in BEC was 1.3 in cases of complete remission, 0.83 in cases with partial response, 0.85 in cases with stable disease and 0.40 in cases with progressive disease. Correlation analysis showed a significant correlation between the decrease in BEC and tumour response (r = -0.24, p = 0.03). BPE decreased by, on average, 0.87 BEC following NAC for breast cancer. The degree of BPE reduction seemed to correlate with tumour response. (orig.)

  1. Mammographic Breast Density in a Cohort of Medically Underserved Women

    Science.gov (United States)

    2015-12-01

    was a training year and during Years 2 through 4 a case-control study of obesity , insulin resistance and mammographic breast density was conducted. A...factors including health literacy, and to collect anthropometric measurements and fasting blood, 3) to assay blood for select hormones and growth...factors, 4) to perform statistical analyses to determine the associations between obesity and insulin resistance and mammographic breast density, and 5

  2. High resolution MRI of the breast at 3 T: which BI-RADS {sup registered} descriptors are most strongly associated with the diagnosis of breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Pinker-Domenig, K.; Helbich, T.H. [Medical University Vienna, Dept. of Radiology, Division of Molecular and Gender Imaging, Vienna (Austria); Bogner, W.; Gruber, S. [Medical University Vienna, Dept. of Radiology, MR Centre of Excellence, Vienna (Austria); Medical University Vienna, Dept. of Radiology, Vienna (Austria); Bickel, H. [Medical University Vienna, Dept. of Radiology, Division of Molecular and Gender Imaging, Vienna (Austria); Medical University Vienna, Dept. of Radiology, Vienna (Austria); Duffy, S. [Queen Mary University of London, Cancer Research UK Centre for Epidemiology, Mathematics and Statistics, Wolfson Institute of Preventive Medicine, Barts and The London School of Medicine and Dentistry, London (United Kingdom); Schernthaner, M. [Medical University Vienna, Dept. of Radiology, Vienna (Austria); Dubsky, P. [Medical University Vienna, Dept. of Surgery, Vienna (Austria); Pluschnig, U. [Medical University Vienna, Dept. of Internal Medicine, Division of Oncology, Vienna (Austria); Rudas, M. [Medical University Vienna, Clinical Institute of Pathology, Vienna (Austria); Trattnig, S. [Medical University Vienna, Dept. of Radiology, MR Centre of Excellence, Vienna (Austria)

    2012-02-15

    To identify which breast lesion descriptors in the ACR BI-RADS registered MRI lexicon are most strongly associated with the diagnosis of breast cancer when performing breast MR imaging at 3 T. 150 patients underwent breast MR imaging at 3 T. Lesion size, morphology and enhancement kinetics were assessed according to the BI-RADS {sup registered} classification. Sensitivity, specificity and diagnostic accuracy were assessed. The effects of the BI-RADS {sup registered} descriptors on sensitivity and specificity were evaluated. Data were analysed using logistic regression. Histopathological diagnoses were used as the standard of reference. The sensitivity, specificity and diagnostic accuracy of breast MRI at 3 T was 99%, 81% and 93%, respectively. In univariate analysis, the final diagnosis of malignancy was positively associated with irregular shape (p < 0.001), irregular margin (p < 0.001), heterogeneous enhancement (p < 0.001), Type 3 enhancement kinetics (p = 0.02), increasing patient age (p = 0.02) and larger lesion size (p < 0.001). In multivariate analysis, significant associations with malignancy remained for mass shape (p = 0.06), mass margin (p < 0.001), internal enhancement pattern (p = 0.03) and Type 3 enhancement kinetics (p = 0.06). The ACR BI-RADS {sup registered} breast lesion descriptors that are mostly strongly associated with breast cancer in breast MR imaging at 3 T are lesion shape, lesion margin, internal enhancement pattern and Type 3 enhancement kinetics. (orig.)

  3. Population of 224 realistic human subject-based computational breast phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, David W. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Wells, Jered R., E-mail: jered.wells@duke.edu [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Sturgeon, Gregory M. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Dobbins, James T. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Segars, W. Paul [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Lo, Joseph Y. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Electrical and Computer Engineering and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2016-01-15

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range

  4. Birth weight, childhood body mass index, and height in relation to mammographic density and breast cancer

    DEFF Research Database (Denmark)

    Andersen, Zorana Jovanovic; Baker, Jennifer Lyn; Bihrmann, Kristine

    2014-01-01

    High breast density, a strong predictor of breast cancer may be determined early in life. Childhood anthropometric factors have been related to breast cancer and breast density, but rarely simultaneously. We examined whether mammographic density (MD) mediates an association of birth weight, child...

  5. Gadolinium-Hematoporphyrin: new potential MRI contrast agent for detection of breast cancer cell line (MCF-7

    Directory of Open Access Journals (Sweden)

    D Shahbazi Gahrouei

    2005-09-01

    Full Text Available Background: Gadolinium-porphyrins have been synthesized and are currently being investigated as magnetic resonance imaging (MRI contrast agents. This study aimed to synthesize Gd-hematoporphyrin and applicate it for in vitro detection of breast cancer cell line (MCF-7. Methods: The naturally occurring porphyrin (hematoporphyrin was inserted with gadolinium (III nitrate hexahydrate to yield Gd-H. T1 relaxation times and signal enhancement of the contrast agents were presented, and the results were compared. UV spectrophotometer measured the attachment of Gd to the cell membrane of MCF-7. Results: Most of gadolinium chloride (GdCl3 was found in the washing solution, indicate that it didn`t fixed to the breast cell membranes during incubation. Gd-DTPA showed some uptake into the MCF-7 cell membranes with incubation, however, its uptake was significantly lower than Gd-H. Conclusion: Good cell memberan uptake of Gd-porphyrin is comparable to controls, indicating selective delivery it to the breast cell line and considerable potency in diagnostic MR imaging for detection of breast cancer. Key Words: Porphyrin, Contrast agent, MRI, Hematoporphyrin, Breast cancer cell (MCF-7

  6. Breast MRI: Are T2 IR sequences useful in the evaluation of breast lesions?

    Energy Technology Data Exchange (ETDEWEB)

    Ballesio, Laura [Department of Radiological Sciences, Umberto I Hospital, ' Sapienza' University of Rome, Viale Del Policlinico 155, 00161 Rome (Italy); Savelli, Sara [Department of Radiological Sciences, Umberto I Hospital, ' Sapienza' University of Rome, Viale Del Policlinico 155, 00161 Rome (Italy)], E-mail: sarasavelli@hotmail.it; Angeletti, Marco; Porfiri, Lucio Maria; D' Ambrosio, Ilaria; Maggi, Claudia; Castro, Elisabetta Di; Bennati, Paolo; Fanelli, Gloria Pasqua [Department of Radiological Sciences, Umberto I Hospital, ' Sapienza' University of Rome, Viale Del Policlinico 155, 00161 Rome (Italy); Vestri, Anna Rita [Department of Experimental Medicine, Umberto I Hospital, ' Sapienza' University of Rome, Viale Del Policlinico 155, 00161 Rome (Italy); Manganaro, Lucia [Department of Radiological Sciences, Umberto I Hospital, ' Sapienza' University of Rome, Viale Del Policlinico 155, 00161 Rome (Italy)

    2009-07-15

    Aim: To evaluate the potential role of signal intensities calculated in T2 images as an adjunctive parameter in the analysis of mass-like enhancements classified as BIRADS (Breast Imaging Reporting and Data System) assessment categories 2, 3, 4 or 5 with the standard T1 criteria. Materials and methods: After a retrospective review of 338-breast Magnetic Resonance Imaging (MRI) performed for the evaluation of a suspicious lesion we selected a group of 65 mass-like enhancements ranging from 5 to 20 mm, classified as BIRADS assessment categories 2, 3, 4 or 5, histologically proved. In all cases we calculated the ratio between the signal intensity (SI) of the nodule and the pectoralis major muscle (LMSIR, lesion to muscle signal intensity ratio) with a multiROIs (region of interest) analysis on T2 images. A ROC analysis was performed to test the ability of the two diagnostic parameters separately considered (BIRADS and LMSIR) and combined in a new mono-dimensional variable obtained by a computerized discriminant function. Results: Histological examination assessed 34 malignant lesions (52.3%) and 31 benign lesions (47.7%). The evaluation of ROC curves gave the following results: BIRADS area under the curve (AUC) 0.913, S.E. 0.0368, LMSIR AUC 0.854, S.E. 0.0487, combined BIRADS-LMSIR AUC 0.965, S.E. 0.0191 with a definitive increase in the AUC between the overall ROC area and those of the two diagnostic modalities separately considered. Discussion: T2-weighted SI assessment with LMSIR measurement improves the diagnostic information content of standard breast MRI and can be considered a promising potential tool in the differential diagnosis of mass-like enhancements judged as borderline lesions (BIRADS 3 and 4)

  7. Additional value of diffusion-weighted imaging to evaluate multifocal and multicentric breast cancer detected using pre-operative breast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Eun; Park, Eun Kyung; Cho, Kyu Ran; Cho, Sung Bum [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seo, Bo Kyoung [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of); Woo, Ok Hee [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Jung, Seung Pil [Korea University Anam Hospital, Korea University College of Medicine, Department of Surgery, Seoul (Korea, Republic of)

    2017-11-15

    To investigate whether diffusion-weighted imaging (DWI) aids pre-operative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to evaluate additional lesions in breast cancer patients. DCE-MRI and DWI were performed on 131 lesions, with available histopathological results. The apparent diffusion coefficient (ADC) of each lesion was measured, and the cut-off value for differentiation between malignant and benign lesions was calculated. A protocol combining the ADC cut-off value with DCE-MRI was validated in a cohort of 107 lesions in 77 patients. When an ADC cut-off value of 1.11 x 10{sup -3} mm{sup 2}/s from the development cohort was applied to the additional lesions in the validation cohort, the specificity increased from 18.9% to 67.6% (P < 0.001), and the diagnostic accuracy increased from 61.7% to 82.2% (P = 0.05), without significant loss of sensitivity (98.6% vs. 90.0%, P = 0.07). The negative predictive values of lesions in the same quadrant had decreased, as had those of lesions ≥1 cm in diameter. The ADC cut-off value in the validation cohort was 1.05 x 10{sup -3} mm{sup 2}/s. Additional implementation of DWI for breast lesions in pre-operative MRI can help to obviate unnecessary biopsies by increasing specificity. However, to avoid missing cancers, clinicians should closely monitor lesions located in the same quadrant or lesions ≥1 cm. (orig.)

  8. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    International Nuclear Information System (INIS)

    Yoshino, Ayako

    1998-01-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds (ΔRT2) was calculated by the following equation: ΔRT2 = (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  9. Efficacy of dynamic susceptibility contrast MRI using echo-planar imaging in differential diagnosis of breast tumors

    Energy Technology Data Exchange (ETDEWEB)

    Yoshino, Ayako [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-07-01

    It has been shown that T1-weighted dynamic MR imaging is a useful method in differentiating malignant breast tumors from benign lesions. Invasive breast carcinomas enhance more rapidly than benign lesions such as fibroadenomas, papillomas, and proliferative fibrocystic diseases. However, significant overlap in the dynamic profile of benign and malignant lesions may occur, resulting in relatively low specificity, which is an inherent limitation of this technique. The author attempted to improve diagnostic accuracy by utilizing dynamic susceptibility contrast MR imaging (DSC-MRI) with a single-shot echo-planar imaging sequence. Twenty-two patients underwent DSC-MRI using a 1.5-T unit (Magnetom Vision, Siemens). Images were obtained before, during and after the bolus injection of 20 mL of gadopentetate dimeglumine. The signal reduction rate within the first 30 seconds ({Delta}RT2) was calculated by the following equation: {Delta}RT2 (postcontrast signal intensity-precontrast signal intensity) /precontrast signal intensity. A rapid, strong decrease in signal intensity was observed on the first pass of the contrast material in all cases of carcinoma, whereas no or only a minimal decrease in signal intensity was observed in all but one of the benign lesions. This method seems to be more accurate than T1-weighted dynamic MR imaging in the differentiation benign and malignant breast lesions. Since DSC-MRI can be performed quickly, subsequent conventional T1-weighted imaging can provide additional information about the morphologic features of lesions, to further support the diagnosis. In conclusion, DSC-MRI seems to be a promising method for the accurate preoperative assessment of breast lesions. (author)

  10. Breast Cancer Redox Heterogeneity Detectable with Chemical Exchange Satruation Transfer (CEST) MRI

    Science.gov (United States)

    Cai, Kejia; Xu, He N.; Singh, Anup; Moon, Lily; Haris, Mohammad; Reddy, Ravinder; Li, Lin

    2014-01-01

    Purpose Tissue redox state is an important mediator of various biological processes in health and diseases such as cancer. Previously, we discovered that the mitochondrial redox state of ex vivo tissues detected by redox scanning (an optical imaging method) revealed interesting tumor redox state heterogeneity that could differentiate tumor aggressiveness. Because the noninvasive chemical exchange saturation transfer (CEST) MRI can probe the proton transfer and generate contrasts from endogenous metabolites, we aim to investigate if the in vivo CEST contrast is sensitive to proton transfer of the redox reactions so as to reveal the tissue redox states in breast cancer animal models. Procedures CEST MRI has been employed to characterize tumor metabolic heterogeneity and correlated with the redox states measured by the redox scanning in two human breast cancer mouse xenograft models, MDA-MB-231 and MCF-7. The possible biological mechanism on the correlation between the two imaging modalities was further investigated by phantom studies where the reductants and the oxidants of the representative redox reactions were measured. Results The CEST contrast is found linearly correlated with NADH concentration and the NADH redox ratio with high statistical significance, where NADH is the reduced form of nicotinamide adenine dinucleotide. The phantom studies showed that the reductants of the redox reactions have more CEST contrast than the corresponding oxidants, indicating that higher CEST effect corresponds to the more reduced redox state. Conclusions This preliminary study suggests that CEST MRI, once calibrated, might provide a novel noninvasive imaging surrogate for the tissue redox state and a possible diagnostic biomarker for breast cancer in the clinic. PMID:24811957

  11. Feature extraction using convolutional neural network for classifying breast density in mammographic images

    Science.gov (United States)

    Thomaz, Ricardo L.; Carneiro, Pedro C.; Patrocinio, Ana C.

    2017-03-01

    Breast cancer is the leading cause of death for women in most countries. The high levels of mortality relate mostly to late diagnosis and to the direct proportionally relationship between breast density and breast cancer development. Therefore, the correct assessment of breast density is important to provide better screening for higher risk patients. However, in modern digital mammography the discrimination among breast densities is highly complex due to increased contrast and visual information for all densities. Thus, a computational system for classifying breast density might be a useful tool for aiding medical staff. Several machine-learning algorithms are already capable of classifying small number of classes with good accuracy. However, machinelearning algorithms main constraint relates to the set of features extracted and used for classification. Although well-known feature extraction techniques might provide a good set of features, it is a complex task to select an initial set during design of a classifier. Thus, we propose feature extraction using a Convolutional Neural Network (CNN) for classifying breast density by a usual machine-learning classifier. We used 307 mammographic images downsampled to 260x200 pixels to train a CNN and extract features from a deep layer. After training, the activation of 8 neurons from a deep fully connected layer are extracted and used as features. Then, these features are feedforward to a single hidden layer neural network that is cross-validated using 10-folds to classify among four classes of breast density. The global accuracy of this method is 98.4%, presenting only 1.6% of misclassification. However, the small set of samples and memory constraints required the reuse of data in both CNN and MLP-NN, therefore overfitting might have influenced the results even though we cross-validated the network. Thus, although we presented a promising method for extracting features and classifying breast density, a greater database is

  12. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  13. Development of a phantom to test fully automated breast density software – A work in progress

    International Nuclear Information System (INIS)

    Waade, G.G.; Hofvind, S.; Thompson, J.D.; Highnam, R.; Hogg, P.

    2017-01-01

    Objectives: Mammographic density (MD) is an independent risk factor for breast cancer and may have a future role for stratified screening. Automated software can estimate MD but the relationship between breast thickness reduction and MD is not fully understood. Our aim is to develop a deformable breast phantom to assess automated density software and the impact of breast thickness reduction on MD. Methods: Several different configurations of poly vinyl alcohol (PVAL) phantoms were created. Three methods were used to estimate their density. Raw image data of mammographic images were processed using Volpara to estimate volumetric breast density (VBD%); Hounsfield units (HU) were measured on CT images; and physical density (g/cm 3 ) was calculated using a formula involving mass and volume. Phantom volume versus contact area and phantom volume versus phantom thickness was compared to values of real breasts. Results: Volpara recognized all deformable phantoms as female breasts. However, reducing the phantom thickness caused a change in phantom density and the phantoms were not able to tolerate same level of compression and thickness reduction experienced by female breasts during mammography. Conclusion: Our results are promising as all phantoms resulted in valid data for automated breast density measurement. Further work should be conducted on PVAL and other materials to produce deformable phantoms that mimic female breast structure and density with the ability of being compressed to the same level as female breasts. Advances in knowledge: We are the first group to have produced deformable phantoms that are recognized as breasts by Volpara software. - Highlights: • Several phantoms of different configurations were created. • Three methods to assess phantom density were implemented. • All phantoms were identified as breasts by the Volpara software. • Reducing phantom thickness caused a change in phantom density.

  14. The relationship between anatomic noise and volumetric breast density for digital mammography

    International Nuclear Information System (INIS)

    Mainprize, James G.; Tyson, Albert H.; Yaffe, Martin J.

    2012-01-01

    Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in β in a clinical population and to indicate the relationship between β and breast density. Methods: From a set of 2686 cranio-caudal normal screening mammograms, the parameter β was extracted from log-log fits to the Wiener spectrum over the range 0.15–1 mm −1 . The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in-house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise. Results: The mean volumetric breast density was 25.5% (±12.6%) over all images. The mean β following a MTF correction which decreased the β slightly (≈−0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm −1 showing small decreases in the result, although the effect of the quantum noise power component on reducing β was clearly observed at 1.5 mm −1 . Conclusions: The texture parameter, β, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between β and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between β and VBD suggests that

  15. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  16. Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

    DEFF Research Database (Denmark)

    Andreasen, Daniel; Van Leemput, Koen; Hansen, Rasmus H.

    2015-01-01

    scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T1-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods...... based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results:The pCTs produced with the patch-based method had the best voxel-wise, geometric......Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan...

  17. Normal parenchymal enhancement patterns in women undergoing MR screening of the breast

    International Nuclear Information System (INIS)

    Jansen, Sanaz A.; Lin, Vicky C.; Giger, Maryellen L.; Li, Hui; Karczmar, Gregory S.; Newstead, Gillian M.

    2011-01-01

    To characterize the kinetic and morphological presentation of normal breast tissue on DCE-MRI in a large cohort of asymptomatic women, and to relate these characteristics to breast tissue density. 335 consecutive breast MR examinations in 229 asymptomatic women undergoing high-risk screening evaluations based on recommendations from the American Cancer Society including strong family history and genetic predisposition were selected for IRB-approved review (average age 49.2 ± 10.5 years). Breast tissue density was assessed on precontrast T 2 -weighted images. Parenchymal enhancement pattern (PEP) was qualitatively classified as minimal, homogeneous, heterogeneous or nodular. Quantitative analysis of parenchymal enhancement kinetics (PEK) was performed, including calculation of initial and peak enhancement percentages (E 1 , E peak ), the time to peak enhancement (T peak ) and the signal enhancement ratio (SER). 41.8% of examinations were classified as minimal, 13.7% homogeneous, 23.9% heterogeneous and 21.2% nodular PEP. Women with heterogeneously or extremely dense breasts exhibited a higher proportion of nodular PEP (44.2% (27/61)) and significantly higher E 1 , and E peak (p < 0.003) compared with those with less dense breasts. Qualitative and quantitative parenchymal enhancement characteristics vary by breast tissue density. In future work, the association between image-derived MR features of the normal breast and breast cancer risk should be explored. (orig.)

  18. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Maijers, M.C.; Ritt, M.J.P.F. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Niessen, F.B. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Jan van Goyen Clinic, Department of Plastic Surgery, Amsterdam (Netherlands); Veldhuizen, J.F.H. [MRI Centre, Amsterdam (Netherlands); Manoliu, R.A. [MRI Centre, Amsterdam (Netherlands); VU University Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2014-06-15

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  19. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    International Nuclear Information System (INIS)

    Maijers, M.C.; Ritt, M.J.P.F.; Niessen, F.B.; Veldhuizen, J.F.H.; Manoliu, R.A.

    2014-01-01

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  20. Background parenchymal enhancement on baseline screening breast MRI: impact on biopsy rate and short-interval follow-up.

    LENUS (Irish Health Repository)

    Hambly, Niamh M

    2011-01-01

    Background parenchymal enhancement on breast MRI refers to normal enhancement of the patient\\'s fibroglandular tissue. The aim of this study was to determine the effect of background parenchymal enhancement on short-interval follow-up, biopsy, and cancer detection rate on baseline screening MRI in a high-risk group.

  1. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    International Nuclear Information System (INIS)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-01-01

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  2. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, Johannes, E-mail: Johannes.grueneisen@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Sawicki, Lino Morris [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Wetter, Axel [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Kirchner, Julian [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Kinner, Sonja [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Aktas, Bahriye [Department of Obstetrics and Gynecology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Ruhlmann, Verena [Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Umutlu, Lale [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany)

    2017-04-15

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  3. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    Science.gov (United States)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-04-01

    To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (psequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the

  4. Digital Breast Tomosynthesis guided Near Infrared Spectroscopy: Volumetric estimates of fibroglandular fraction and breast density from tomosynthesis reconstructions.

    Science.gov (United States)

    Vedantham, Srinivasan; Shi, Linxi; Michaelsen, Kelly E; Krishnaswamy, Venkataramanan; Pogue, Brian W; Poplack, Steven P; Karellas, Andrew; Paulsen, Keith D

    A multimodality system combining a clinical prototype digital breast tomosynthesis with its imaging geometry modified to facilitate near-infrared spectroscopic imaging has been developed. The accuracy of parameters recovered from near-infrared spectroscopy is dependent on fibroglandular tissue content. Hence, in this study, volumetric estimates of fibroglandular tissue from tomosynthesis reconstructions were determined. A kernel-based fuzzy c-means algorithm was implemented to segment tomosynthesis reconstructed slices in order to estimate fibroglandular content and to provide anatomic priors for near-infrared spectroscopy. This algorithm was used to determine volumetric breast density (VBD), defined as the ratio of fibroglandular tissue volume to the total breast volume, expressed as percentage, from 62 tomosynthesis reconstructions of 34 study participants. For a subset of study participants who subsequently underwent mammography, VBD from mammography matched for subject, breast laterality and mammographic view was quantified using commercial software and statistically analyzed to determine if it differed from tomosynthesis. Summary statistics of the VBD from all study participants were compared with prior independent studies. The fibroglandular volume from tomosynthesis and mammography were not statistically different ( p =0.211, paired t-test). After accounting for the compressed breast thickness, which were different between tomosynthesis and mammography, the VBD from tomosynthesis was correlated with ( r =0.809, p 0.99, paired t-test), and was linearly related to, the VBD from mammography. Summary statistics of the VBD from tomosynthesis were not statistically different from prior studies using high-resolution dedicated breast computed tomography. The observation of correlation and linear association in VBD between mammography and tomosynthesis suggests that breast density associated risk measures determined for mammography are translatable to tomosynthesis

  5. Relationship between Background Parenchymal Enhancement on High-risk Screening MRI and Future Breast Cancer Risk.

    Science.gov (United States)

    Grimm, Lars J; Saha, Ashirbani; Ghate, Sujata V; Kim, Connie; Soo, Mary Scott; Yoon, Sora C; Mazurowski, Maciej A

    2018-03-27

    To determine if background parenchymal enhancement (BPE) on screening breast magnetic resonance imaging (MRI) in high-risk women correlates with future cancer. All screening breast MRIs (n = 1039) in high-risk women at our institution from August 1, 2004, to July 30, 2013, were identified. Sixty-one patients who subsequently developed breast cancer were matched 1:2 by age and high-risk indication with patients who did not develop breast cancer (n = 122). Five fellowship-trained breast radiologists independently recorded the BPE. The median reader BPE for each case was calculated and compared between the cancer and control cohorts. Cancer cohort patients were high-risk because of a history of radiation therapy (10%, 6 of 61), high-risk lesion (18%, 11 of 61), or breast cancer (30%, 18 of 61); BRCA mutation (18%, 11 of 61); or family history (25%, 15 of 61). Subsequent malignancies were invasive ductal carcinoma (64%, 39 of 61), ductal carcinoma in situ (30%, 18 of 61) and invasive lobular carcinoma (7%, 4of 61). BPE was significantly higher in the cancer cohort than in the control cohort (P = 0.01). Women with mild, moderate, or marked BPE were 2.5 times more likely to develop breast cancer than women with minimal BPE (odds ratio = 2.5, 95% confidence interval: 1.3-4.8, P = .005). There was fair interreader agreement (κ = 0.39). High-risk women with greater than minimal BPE at screening MRI have increased risk of future breast cancer. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients; Wertigkeit der Mamma-MRT als Ergaenzung zu Mammographie und Sonographie bei Patientinnen mit erhoehtem Mammakarzinomrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2008-04-15

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [German] Ziele der Arbeit sind die inhaltliche Einfuehrung in das Thema Frueherkennung des Mammakarzinoms bei Patientinnen mit erhoehtem Risiko und eine systematische Analyse der Wertigkeit von MRT und anderen bildgebenden Verfahren in diesem Zusammenhang. Es wurde eine systematische Literaturrecherche ueber die letzten 3 Jahre durchgefuehrt. Dabei wurden Vergleichsstudien der verschiedenen bildgebenden Verfahren in der Mammadiagnostik beruecksichtigt, bei denen die bildgesteuerte Biopsie als Goldstandard angegeben wurde. Von allen bildgebenden Verfahren zeigt die Mamma-MRT bei Patientinnen mit familiaerem Risiko die hoechste Sensitivitaet und diagnostische Genauigkeit bei der Detektion des Mammakarzinoms. Fuer MRT, Mammographie und Sonographie werden Sensitivitaeten zwischen 71 und 100%, 0 und 78% sowie 13 und 65% angegeben. Die Mamma-MRT ist ein etabliertes Verfahren zum Screening von Risikopatientinnen. Uebereinstimmend wird der diagnostische Nutzen der Mamma-MRT als ergaenzendes Verfahren zu Mammographie

  7. Photoacoustic imaging of breast tumor vascularization: a comparison with MRI and histopathology

    Science.gov (United States)

    Heijblom, Michelle; Piras, Daniele; van den Engh, Frank M.; Klaase, Joost M.; Brinkhuis, Mariël.; Steenbergen, Wiendelt; Manohar, Srirang

    2013-06-01

    Breast cancer is the most common form of cancer and the leading cause of cancer death among females. Early diagnosis improves the survival chances for the disease and that is why there is an ongoing search for improved methods for visualizing breast cancer. One of the hallmarks of breast cancer is the increase in tumor vascularization that is associated with angiogenesis: a crucial factor for survival of malignancies. Photoacoustic imaging can visualize the malignancyassociated increased hemoglobin concentration with optical contrast and ultrasound resolution, without the use of ionizing radiation or contrast agents and is therefore theoretically an ideal method for breast imaging. Previous clinical studies using the Twente Photoacoustic Mammoscope (PAM), which works in forward mode using a single wavelength (1064 nm), showed that malignancies can indeed be identified in the photoacoustic imaging volume as high contrast areas. However, the specific appearance of the malignancies led to questions about the contrast mechanism in relation to tumor vascularization. In this study, the photoacoustic lesion appearance obtained with an updated version of PAM is compared with the lesion appearance on Magnetic Resonance Imaging (MRI), both in general (19 patients) and on an individual basis (7 patients). Further, in 3 patients an extended histopathology protocol is being performed in which malignancies are stained for vascularity using an endothelial antibody: CD31. The correspondence between PAM and MRI and between PAM and histopathology makes it likely that the high photoacoustic contrast at 1064 nm is indeed largely the consequence of the increased tumor vascularization.

  8. Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Sakurai, Kota; Nakano, Masahiro; Maeda, Sunaho; Kajita, Kimihiro R.T.; Deguchi, Takashi; Hoshi, Hiroaki

    2006-01-01

    Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 ± 6.17 cc (mean ± SD) in MRI-based dosimetry, and 15.97 ± 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported

  9. Volumetric mammographic density: heritability and association with breast cancer susceptibility loci.

    Science.gov (United States)

    Brand, Judith S; Humphreys, Keith; Thompson, Deborah J; Li, Jingmei; Eriksson, Mikael; Hall, Per; Czene, Kamila

    2014-12-01

    Mammographic density is a strong heritable trait, but data on its genetic component are limited to area-based and qualitative measures. We studied the heritability of volumetric mammographic density ascertained by a fully-automated method and the association with breast cancer susceptibility loci. Heritability of volumetric mammographic density was estimated with a variance component model in a sib-pair sample (N pairs = 955) of a Swedish screening based cohort. Associations with 82 established breast cancer loci were assessed in an independent sample of the same cohort (N = 4025 unrelated women) using linear models, adjusting for age, body mass index, and menopausal status. All tests were two-sided, except for heritability analyses where one-sided tests were used. After multivariable adjustment, heritability estimates (standard error) for percent dense volume, absolute dense volume, and absolute nondense volume were 0.63 (0.06) and 0.43 (0.06) and 0.61 (0.06), respectively (all P associated with rs10995190 (ZNF365; P = 9.0 × 10(-6) and 8.9 × 10(-7), respectively) and rs9485372 (TAB2; P = 1.8 × 10(-5) and 1.8 × 10(-3), respectively). We also observed associations of rs9383938 (ESR1) and rs2046210 (ESR1) with the absolute dense volume (P = 2.6 × 10(-4) and 4.6 × 10(-4), respectively), and rs6001930 (MLK1) and rs17356907 (NTN4) with the absolute nondense volume (P = 6.7 × 10(-6) and 8.4 × 10(-5), respectively). Our results support the high heritability of mammographic density, though estimates are weaker for absolute than percent dense volume. We also demonstrate that the shared genetic component with breast cancer is not restricted to dense tissues only. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  10. MR imaging of the augmented and reconstructed breast

    International Nuclear Information System (INIS)

    Ivanov, V.; Kirova, G.

    2013-01-01

    Full text: Introduction: Various diagnostic methods are used to assess the changes in both the integrity of the implant, and the fibrous capsule of breast parenchyma. MRI has advantages over other diagnostic methods providing high tissue contrast, multi-faceted imaging and lack of ionizing radiation. What you will learn: MRI evaluation of breast augmentation approaches and their complications, MRI assessment of disease with malignant and benign characteristics in patients with breast implants, MRI assessment of breast reconstruction with autologous tissue. Discussion: Mammography after augmentation and reconstructive mammoplasty is hampered by the deformation of the breast parenchyma of the implant and the reduced compression. Postoperative scarring is also difficult to assess. MRI evaluation of implant rupture is accurate using the findings specific to it - linguine sign, teardrop sign or siliconomas. According to Gorczyca et al. MRI has a sensitivity 94% and specificity 97% in the evaluation of rupture. MRI mammography is highly sensitive - between 90 and 95%, in the detection of malignant, but it has limited specificity, which is its disadvantage. Malignant lesions can be represented as fibroadenomas, postoperative and inflammatory changes. Conclusion: Difficulties in the diagnosis of rupture of the implant, the primary and recurrent carcinoma based on clinical examination and inconclusive data from mammography and ultrasound imaging make MRI the method of choice in the evaluation of patients with breast implants

  11. Pilot study of quantitative analysis of background enhancement on breast MR images: association with menstrual cycle and mammographic breast density.

    Science.gov (United States)

    Scaranelo, Anabel M; Carrillo, Maria Claudia; Fleming, Rachel; Jacks, Lindsay M; Kulkarni, Supriya R; Crystal, Pavel

    2013-06-01

    To perform semiautomated quantitative analysis of the background enhancement (BE) in a cohort of patients with newly diagnosed breast cancer and to correlate it with mammographic breast density and menstrual cycle. Informed consent was waived after the research ethics board approved this study. Results of 177 consecutive preoperative breast magnetic resonance (MR) examinations performed from February to December 2009 were reviewed; 147 female patients (median age, 48 years; range, 26-86 years) were included. Ordinal values of BE and breast density were described by two independent readers by using the Breast Imaging Reporting and Data System lexicon. The BE coefficient (BEC) was calculated thus: (SI2 · 100/SI1) - 100, where SI is signal intensity, SI2 is the SI enhancement measured in the largest anteroposterior dimension in the axial plane 1 minute after the contrast agent injection, and SI1is the SI before contrast agent injection. BEC was used for the quantitative analysis of BE. Menstrual cycle status was based on the last menstrual period. The Wilcoxon rank-sum or Kruskal-Wallis test was used to compare quantitative assessment groups. Cohen weighted κ was used to evaluate agreement. Of 147 patients, 68 (46%) were premenopausal and 79 (54%) were postmenopausal. The quantitative BEC was associated with the menstrual status (BEC in premenopausal women, 31.48 ± 20.68 [standard deviation]; BEC in postmenopausal women, 25.65 ± 16.74; P = .02). The percentage of overall BE was higher when the MR imaging was performed in women in the inadequate phase of the cycle (quantitative BE than postmenopausal women. No association was found between BE and breast density.

  12. Dynamic contrast-enhanced MRI and sonography in patients receiving primary chemotherapy for breast cancer

    International Nuclear Information System (INIS)

    Montemurro, Filippo; Aglietta, Massimo; Martincich, Laura; Rosa, Giovanni De; Cirillo, Stefano; Marra, Vincenzo; Regge, Daniele; Biglia, Nicoletta; Sismondi, Piero; Gatti, Marco

    2005-01-01

    We compared dynamic contrast-enhanced MRI (DCE-MRI) and sonography (US) for monitoring tumour size in 21 patients with breast cancer undergoing primary chemotherapy (PCT) followed by surgery. The correlation between DCE-MRI and US measurements of tumour size, defined as the product of the two major diameters, was 0.555 (P=0.009), 0.782 (P 2 , P 2 , P=0.009). After PCT, the median tumour size measured by the two techniques was similar (256 vs 289 mm 2 for DCE-MRI and US, respectively, P=0.859). The correlation with the histopathological major tumour diameter was 0.824 (P<0.001) and 0.705 (P<0.001) for post-treatment DCE-MRI and US, respectively. Measurements of the final major tumour diameter by DCE-MRI tended to be more precise, including cases achieving a pathological complete response. Randomized trials are warranted to establish the clinical impact of the initial discrepancy in tumour size estimates between DCE-MRI and US, and the trend towards a better definition of the final tumour size provided by DCE-MRI in this clinical setting. (orig.)

  13. Magnetic resonance imaging features of fibrocystic change of the breast.

    Science.gov (United States)

    Chen, Jeon-Hor; Liu, Hui; Baek, Hyeon-Man; Nalcioglu, Orhan; Su, Min-Ying

    2008-11-01

    Studies specifically reporting MRI of fibrocystic change (FCC) of the breast are very few and its MRI features are not clearly known. The purpose of this study was to analyze the MRI features of FCC of the breast. Thirty-one patients with pathologically proven FCC of the breast were retrospectively reviewed. The MRI study was performed using a 1.5-T MR scanner with standard bilateral breast coil. The imaging protocol consisted of pre-contrast T1-weighed imaging and dynamic contrast-enhanced axial T1-weighed imaging. The MRI features were interpreted based on the morphologic and enhancement kinetic descriptors defined on ACR BIRADS-MRI lexicon. FCC of the breast had a wide spectrum of morphologic and kinetic features on MRI. Two types of FCC were found, including a more diffuse type of nonmass lesion (12/31, 39%) showing benign enhancement kinetic pattern with medium wash-in in early phase (9/10, 90%) and a focal mass-type lesion (11/31, 35%) with enhancement kinetic usually showing rapid up-slope mimicking a breast cancer (8/11, 73%). MRI is able to elaborate the diverse imaging features of FCC of the breast. Our result showed that FCC presenting as a focal mass-type lesion was usually overdiagnosed as malignancy. Understanding MRI of FCC is important to determine which cohort of patients should be followed up alone or receive aggressive management.

  14. Prospective MRI assessment for invasive lobular breast cancer. Correlation with tumour size at histopathology and influence on surgical management

    International Nuclear Information System (INIS)

    Muttalib, M.; Ibrahem, R.; Khashan, A.S.; Hajaj, M.

    2014-01-01

    Aim: To evaluate the performance of breast magnetic resonance imaging (MRI) in determining the size of invasive lobular carcinoma (ILC) compared to histopathology, and its influence on breast surgical management. Materials and methods: Prospective evaluation was undertaken of standardized contrast-enhanced MRI images of 51 consecutive women over an 18 month period with pure ILC or with lobular features as the dominant subtype on breast core biopsy. Image interpretation was performed by one consultant radiologist (M.H.). The lesion size at MRI was compared with the size at final histopathology after surgical excision using a Bland–Altman agreement plot. Results: Of the 51 prospectively imaged consecutive women, seven were excluded as they had diffuse ILC. The remaining 44 patients had a mean histological tumour size of 34.9 mm (range 4–77 mm). MRI underestimated tumour size in 26 (59.1%) cases. In 21 (47.7%) patients, this discrepancy was small, ranging up to 16 mm. The largest underestimation occurred in five (11.4%) cases with a difference ranging between 31 and 48 mm. Fifteen (34.1%) tumours were overestimated by MRI where the discrepancy ranged up to 22 mm. In three (6.8%) patients MRI and histological size matched. The Bland–Altman agreement plot demonstrated that in 95% of cases the size at histopathology will be between 0.36 and 2.31 times the MRI size at extremes. MRI correlated better with histopathology in tumours up to T2 (<5 cm) size leading to a change in surgical management for nine of the 44 (20.5%) patients. Conclusion: MRI enables surgical management decisions to be made with increased confidence in patients with ILC up to T2 size

  15. A deep learning classifier for prediction of pathological complete response to neoadjuvant chemotherapy from baseline breast DCE-MRI

    Science.gov (United States)

    Ravichandran, Kavya; Braman, Nathaniel; Janowczyk, Andrew; Madabhushi, Anant

    2018-02-01

    Neoadjuvant chemotherapy (NAC) is routinely used to treat breast tumors before surgery to reduce tumor size and improve outcome. However, no current clinical or imaging metrics can effectively predict before treatment which NAC recipients will achieve pathological complete response (pCR), the absence of residual invasive disease in the breast or lymph nodes following surgical resection. In this work, we developed and applied a convolu- tional neural network (CNN) to predict pCR from pre-treatment dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) scans on a per-voxel basis. In this study, DCE-MRI data for a total of 166 breast cancer pa- tients from the ISPY1 Clinical Trial were split into a training set of 133 patients and a testing set of 33 patients. A CNN consisting of 6 convolutional blocks was trained over 30 epochs. The pre-contrast and post-contrast DCE-MRI phases were considered in isolation and conjunction. A CNN utilizing a combination of both pre- and post-contrast images best distinguished responders, with an AUC of 0.77; 82% of the patients in the testing set were correctly classified based on their treatment response. Within the testing set, the CNN was able to produce probability heatmaps that visualized tumor regions that most strongly predicted therapeutic response. Multi- variate analysis with prognostic clinical variables (age, largest diameter, hormone receptor and HER2 status), revealed that the network was an independent predictor of response (p=0.05), and that the inclusion of HER2 status could further improve capability to predict response (AUC = 0.85, accuracy = 85%).

  16. Support vector machine for breast cancer classification using diffusion-weighted MRI histogram features: Preliminary study.

    Science.gov (United States)

    Vidić, Igor; Egnell, Liv; Jerome, Neil P; Teruel, Jose R; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F; Goa, Pål Erik

    2018-05-01

    Diffusion-weighted MRI (DWI) is currently one of the fastest developing MRI-based techniques in oncology. Histogram properties from model fitting of DWI are useful features for differentiation of lesions, and classification can potentially be improved by machine learning. To evaluate classification of malignant and benign tumors and breast cancer subtypes using support vector machine (SVM). Prospective. Fifty-one patients with benign (n = 23) and malignant (n = 28) breast tumors (26 ER+, whereof six were HER2+). Patients were imaged with DW-MRI (3T) using twice refocused spin-echo echo-planar imaging with echo time / repetition time (TR/TE) = 9000/86 msec, 90 × 90 matrix size, 2 × 2 mm in-plane resolution, 2.5 mm slice thickness, and 13 b-values. Apparent diffusion coefficient (ADC), relative enhanced diffusivity (RED), and the intravoxel incoherent motion (IVIM) parameters diffusivity (D), pseudo-diffusivity (D*), and perfusion fraction (f) were calculated. The histogram properties (median, mean, standard deviation, skewness, kurtosis) were used as features in SVM (10-fold cross-validation) for differentiation of lesions and subtyping. Accuracies of the SVM classifications were calculated to find the combination of features with highest prediction accuracy. Mann-Whitney tests were performed for univariate comparisons. For benign versus malignant tumors, univariate analysis found 11 histogram properties to be significant differentiators. Using SVM, the highest accuracy (0.96) was achieved from a single feature (mean of RED), or from three feature combinations of IVIM or ADC. Combining features from all models gave perfect classification. No single feature predicted HER2 status of ER + tumors (univariate or SVM), although high accuracy (0.90) was achieved with SVM combining several features. Importantly, these features had to include higher-order statistics (kurtosis and skewness), indicating the importance to account for heterogeneity. Our

  17. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    Science.gov (United States)

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  18. Atlas-based deformable image registration for MRI-guided prostate radiation therapy

    International Nuclear Information System (INIS)

    Dowling, J.; Fripp, J.; Salvado, O.; Lambert, J.; Denham, J.W.; Capp, A.; Grer, P.B.; Parker, J.

    2010-01-01

    Full text: To develop atlas-based deformable image registration methods to automatically segment organs and map electron densities to pelvic MRI scans for MRI-guided radiation therapy. Methods An MRT pelvic atlas and corresponding CT atlas were developed based on whole pelvic T 2 MRI scans and CT scans for 39 patients. Expert manual segmentations on both MRI and CT scans were obtained. The atlas was deformably registered to the individual patient MRI scans for automatic prostate, rectum, bladder and bone segmentation. These were compared to the manual segmentations using the Dice overlap coefficient. The same deformation vectors were then applied to the CT-atlas to produce pseudo-CT scans that correspond to the patient MRI scan anatomy but are populated with Hounsfield units. The original patient plan was recalculated on the pseudo-CT and compared to the original CT plan and bulk density plans on the MRI scans. Results Dice coefficient results were high (>0.8) for bone and prostate but lower (<0.7) for bladder and rectum which exhibit greater changes in shape and volume. Doses calculated on pseudo-CT scans were within 3% of original patient plans. Two sources of discrepancy were found; MR anatomy differences from CT due to patient setup differences at the MR scanner. and Hounsfield unit differences for bone in the pseudo-CT from original CT. Patient setup will be adressed with a

  19. Visually assessed breast density, breast cancer risk and the importance of the craniocaudal view.

    NARCIS (Netherlands)

    Duffy, S.W.; Nagtegaal, I.D.; Astley, S.M.; Gillan, M.G.; McGee, M.A.; Boggis, C.R.; Wilson, M.; Beetles, U.M.; Griffiths, M.A.; Jain, A.K.; Johnson, J.; Roberts, R.; Deans, H.; Duncan, K.A.; Iyengar, G.; Griffiths, P.M.; Warwick, J.; Cuzick, J.; Gilbert, F.J.

    2008-01-01

    INTRODUCTION: Mammographic density is known to be a strong risk factor for breast cancer. A particularly strong association with risk has been observed when density is measured using interactive threshold software. This, however, is a labour-intensive process for large-scale studies. METHODS: Our

  20. Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imaging.

    Science.gov (United States)

    Schilling, Kathy; Narayanan, Deepa; Kalinyak, Judith E; The, Juliette; Velasquez, Maria Victoria; Kahn, Simone; Saady, Matthew; Mahal, Ravinder; Chrystal, Larraine

    2011-01-01

    The objective of this study was to compare the performance characteristics of (18)F-fluorodeoxyglucose (FDG) positron emission mammography (PEM) with breast magnetic resonance imaging (MRI) as a presurgical imaging and planning option for index and ipsilateral lesions in patients with newly diagnosed, biopsy-proven breast cancer. Two hundred and eight women >25 years of age (median age = 59.7 ± 14.1 years) with biopsy-proven primary breast cancer enrolled in this prospective, single-site study. MRI, PEM, and whole-body positron emission tomography (WBPET) were conducted on each patient within 7 business days. PEM and WBPET images were acquired on the same day after intravenous administration of 370 MBq of FDG (median = 432.9 MBq). PEM and MRI images were blindly evaluated, compared with final surgical histopathology, and the sensitivity determined. Substudy analysis compared the sensitivity of PEM versus MRI in patients with different menopausal status, breast density, and use of hormone replacement therapy (HRT) as well as determination of performance characteristics for additional ipsilateral lesion detection. Two hundred and eight patients enrolled in the study of which 87% (182/208) were analyzable. Of these analyzable patients, 26.4% (48/182), 7.1% (13/182), and 64.2% (120/182) were pre-, peri-, and postmenopausal, respectively, and 48.4% (88/182) had extremely or heterogeneously dense breast tissue, while 33.5% (61/182) had a history of HRT use. Ninety-two percent (167/182) underwent core biopsy for index lesion diagnosis. Invasive cancer was found in 77.5% (141/182), while ductal carcinoma in situ (DCIS) and/or Paget's disease were found in 22.5% (41/182) of patients. Both PEM and MRI had index lesion depiction sensitivity of 92.8% and both were significantly better than WBPET (67.9%, p performance characteristics are not affected by patient menopausal/hormonal status or breast density.

  1. Comprehensive imaging of tumor recurrence in breast cancer patients using whole-body MRI at 1.5 and 3 T compared to FDG-PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany)], E-mail: gerwin.schmidt@med.uni-muenchen.de; Baur-Melnyk, Andrea [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Haug, Alexander [Department of Nuclear Medicine, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Heinemann, Volker [Department of Internal Medicine III, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Bauerfeind, Ingo [Department of Obstetrics and Gynecology, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Reiser, Maximilian F. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Schoenberg, Stefan O. [Institute of Clinical Radiology University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg (Germany)

    2008-01-15

    Purpose: To compare the diagnostic accuracy for the detection of tumor recurrence in breast cancer patients using whole-body-MRI (WB-MRI) at 1.5 or 3 T compared to FDG-PET-CT. Materials and methods: Thirty-three female patients with breast cancer and suspicion of recurrence underwent FDG-PET-CT and WB-MRI. Coronal T1w-TSE- and STIR-sequences, HASTE-imaging of the lungs, contrast-enhanced T1w- and T2w-TSE-sequences of the liver, brain and abdomen were performed, using a WB-MRI-scanner at 1.5 (n = 23) or 3 T (n = 10). Presence of local recurrence, lymph node involvement and distant metastatic disease was assessed using clinical and radiological follow-up as a standard of reference. Results: Tumor recurrence was found in 20 of 33 patients. Overall 186 malignant foci were detected with WB-MRI and PET-CT. Both modalities revealed two recurrent tumors of the breast. PET-CT detected more lymph node metastases (n = 21) than WB-MRI (n = 16). WB-MRI was more precise in the detection of distant metastases (n = 154 versus n = 147). Sensitivity was 93% (172/186) and 91% (170/186) for WB-MRI and PET-CT, specificity was 86% (66/77) and 90% (69/77), respectively. Examination times for WB-MRI at 1.5 and 3 T were 51 and 43 min, respectively, examination time for PET-CT was 103 min. Conclusion: WB-MRI and PET-CT are useful for the detection of tumor recurrence in the follow-up of breast cancer. WB-MRI is highly sensitive to distant metastatic disease. PET-CT is more sensitive in detecting lymph node involvement. Tumor screening with WB-MRI is feasible at 1.5 and 3 T, scan time is further reduced at 3 T with identical resolution.

  2. SU-E-J-239: IMRT Planning of Prostate Cancer for a MRI-Linac Based On MRI Only

    Energy Technology Data Exchange (ETDEWEB)

    Chen, X; Prior, P; Paulson, E; Lawton, C; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2014-06-01

    Purpose: : To investigate dosimetric differences between MRI- and CT-based IMRT planning for prostate cancer, the impact of a magnetic field in a MRI-Linac, and to explore the feasibility of IMRT planning based on MRI alone. Methods: IMRT plans were generated based on CT and MRI images acquired on two representative prostate-cancer patients using clinical dose volume constraints. A research planning system (Monaco, Elekta), which employs a Monte Carlo dose engine and includes a perpendicular magnetic field of 1.5T from an MRI-Linac, was used. Bulk electron density assignments based on organ-specific values from ICRU 46 were used to convert MRI (T2) to pseudo CT. With the same beam configuration as in the original CT plan, 5 additional plans were generated based on CT or MRI, with or without optimization (i.e., just recalculation) and with or without the magnetic field. The plan quality in terms of commonly used dose volume (DV) parameters for all plans was compared. The statistical uncertainty on dose was < 1%. Results: For plans with the same contour set but without re-optimization, the DV parameters were different from those for the original CT plan, mostly less than 5% with a few exceptions. These differences were reduced to mostly less than 3% when the plans were re-optimized. For plans with contours from MRI, the differences in the DV parameters varied depending on the difference in the contours as compared to CT. For the optimized plans with contours from MR, the differences for PTV were less than 3%. Conclusion: The prostate IMRT plans based on MRI-only for a MR-Linac were practically similar as compared to the CT plan under the same beam and optimization configuration if the difference on the structure delineation is excluded, indicating the feasibility of using MRI-only for prostate IMRT.

  3. Comparative analysis of methods for extracting vessel network on breast MRI images

    Science.gov (United States)

    Gaizer, Bence T.; Vassiou, Katerina G.; Lavdas, Eleftherios; Arvanitis, Dimitrios L.; Fezoulidis, Ioannis V.; Glotsos, Dimitris T.

    2017-11-01

    Digital processing of MRI images aims to provide an automatized diagnostic evaluation of regular health screenings. Cancerous lesions are proven to cause an alteration in the vessel structure of the diseased organ. Currently there are several methods used for extraction of the vessel network in order to quantify its properties. In this work MRI images (Signa HDx 3.0T, GE Healthcare, courtesy of University Hospital of Larissa) of 30 female breasts were subjected to three different vessel extraction algorithms to determine the location of their vascular network. The first method is an experiment to build a graph over known points of the vessel network; the second algorithm aims to determine the direction and diameter of vessels at these points; the third approach is a seed growing algorithm, spreading selection to neighbors of the known vessel pixels. The possibilities shown by the different methods were analyzed, and quantitative measurements were performed. The data provided by these measurements showed no clear correlation with the presence or malignancy of tumors, based on the radiological diagnosis of skilled physicians.

  4. Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

    Science.gov (United States)

    Song, Sung Eun; Cho, Nariya; Han, Wonshik

    2017-12-01

    To evaluate whether the post-clip placement MRI following second-look ultrasound (US)-guided core biopsy is useful to confirm the adequate sampling of suspicious lesions identified on breast MRI. Between 2014 and 2016, 31 consecutive women with 34 suspicious lesions that had not been identified on previous mammography or US were detected using MRI. Among them, 26 women with 29 lesions (mean size 1.5 cm, range 0.5-5.8 cm) found by second-look US underwent US-guided biopsy, subsequent clip insertion and post-clip placement MRI. Five women with five lesions that were not found by second-look US underwent MRI-guided biopsy. The technical success rate and lesion characteristics were described. The technical success rate was 96.6% (28/29). One failure case was a benign, 1.1-cm non-mass enhancement. Of the 28 success cases, 23 (82.1%) were masses and 5 (17.9%) were non-mass enhancements; 17 (60.7%) were benign, 4 (14.3%) were high-risk and 7 (25.0%) were malignant lesions. The technical success rate was 100% (28/28) for masses and 83.3% (5/6) for non-mass enhancements. Post-clip placement MRI following US-guided biopsy is useful in confirming the adequate sampling of lesions identified on MRI. This method could be an alternative to MRI-guided biopsy for lesions visible on US. • Post-clip MRI is useful for confirming adequate sampling of US-guided biopsy. • Post-clip MRI following US-guided biopsy revealed a 96.6 % technical success rate. • One technical failure case was a benign, 1.1-cm non-mass enhancement. • The technical success rate of US-guided biopsy for non-mass enhancements was 83.3 %.

  5. Ultra high spatial and temporal resolution breast imaging at 7T.

    Science.gov (United States)

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  6. Whole-body MRI in preoperative diagnostics of breast cancer. A comparison with staging methods according to the S 3 guidelines

    International Nuclear Information System (INIS)

    Hausmann, D.; Schoenberg, S.O.; Neff, K.W.; Dinter, D.J.; Kern, C.; Schroeder, M.T.; Suetterlin, M.

    2011-01-01

    Purpose: The German Society of Senology (step-3 guidelines for the early recognition of breast cancer in Germany) recommends whole-body staging including chest X-ray, ultrasound of the liver and bone scintigraphy before systemic therapy in patients with breast cancer. The performance of these three examinations is time-consuming and involves radiation exposure. Whole-body MR imaging (WB-MRI) allows staging in a single examination without radiation exposure. The purpose of this study was to compare the diagnostic accuracy of WB-MRI with staging according to the guidelines. Materials and Methods: During 04/07 and 06/09, the initial staging in 51 patients (56 ± 12 yrs) with breast cancer (24 patients with lymph node metastases) was performed according to the S 3-guidelines. Additionally, all patients underwent contrast-enhanced WB-MRI (1.5-Tesla-Magnetom Avanto, Siemens, Erlangen). The findings of the different modalities were compared after correlation of the lesions by follow-up. The detection of suspicious findings and the accuracy of prediction of malignancy of the detected lesions were evaluated. Results: Overall, 14 metastases were detected in 4 of 51 patients after completion of the follow-up. By means of WB-MRI, all 14 metastases could be detected, while just 4 of these metastases were identified by the conventional methods. Conclusion: The detection of distant metastases has an important impact on patient management. In this study WB-MRI in breast cancer staging has shown promising results in regard to possible clinical implementation as a matter of routine staging. (orig.)

  7. Breast imaging reporting and data system (BI-RADS) lexicon for breast MRI: Interobserver variability in the description and assignment of BI-RADS category

    International Nuclear Information System (INIS)

    El Khoury, Mona; Lalonde, Lucie; David, Julie; Labelle, Maude; Mesurolle, Benoit; Trop, Isabelle

    2015-01-01

    Highlights: • The use of BI-RADS lexicon in interpreting breast MRI examinations is beneficial. • Our study shows: (a) moderate to substantial agreement between observers and (b) better agreement in interpreting mass than non-mass enhancement (NME). • Careful analysis of the NME should be done to help detect cancer as early as possible. - Abstract: Purpose: To retrospectively evaluate interobserver variability between breast radiologists when describing abnormal enhancement on breast MR examinations and assigning a BI-RADS category using the Breast Imaging Reporting and Data System (BI-RADS) terminology. Materials and methods: Five breast radiologists blinded to patients’ medical history and pathologic results retrospectively and independently reviewed 257 abnormal areas of enhancement on breast MRI performed in 173 women. Each radiologist described the focal enhancement using BI-RADS terminology and assigned a final BI-RADS category. Krippendorff's α coefficient of agreement was used to asses interobserver variability. Results: All radiologists agreed on the morphology of enhancement in 183/257 (71%) lesions, yielding a substantial agreement (Krippendorff's α = 0.71). Moderate agreement was obtained for mass descriptors – shape, margins and internal enhancement – (α = 0.55, 0.51 and 0.45 respectively) and NME (non-mass enhancement) descriptors – distribution and internal enhancement – (α = 0.54 and 0.43). Overall substantial agreement was obtained for BI-RADS category assignment (α = 0.71). It was however only moderate (α = 0.38) for NME compared to mass (α = 0.80). Conclusion: Our study shows good agreement in describing mass and NME on a breast MR examination but a better agreement in predicting malignancy for mass than NME

  8. Breast imaging reporting and data system (BI-RADS) lexicon for breast MRI: Interobserver variability in the description and assignment of BI-RADS category

    Energy Technology Data Exchange (ETDEWEB)

    El Khoury, Mona, E-mail: monelkhoury@gmail.com [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada); Lalonde, Lucie; David, Julie; Labelle, Maude [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada); Mesurolle, Benoit [Centre Hospitalier Universitaire de McGill, Cedar Breast Centre, Radiology Department, 687 Pine Avenue West, Montreal, QC H3A1A1 (Canada); Trop, Isabelle [Centre Hospitalier Universitaire de Montréal, Breast Centre, Radiology Department, 3840 Rue Saint Urbain, Montréal, QC H2W1T8 (Canada)

    2015-01-15

    Highlights: • The use of BI-RADS lexicon in interpreting breast MRI examinations is beneficial. • Our study shows: (a) moderate to substantial agreement between observers and (b) better agreement in interpreting mass than non-mass enhancement (NME). • Careful analysis of the NME should be done to help detect cancer as early as possible. - Abstract: Purpose: To retrospectively evaluate interobserver variability between breast radiologists when describing abnormal enhancement on breast MR examinations and assigning a BI-RADS category using the Breast Imaging Reporting and Data System (BI-RADS) terminology. Materials and methods: Five breast radiologists blinded to patients’ medical history and pathologic results retrospectively and independently reviewed 257 abnormal areas of enhancement on breast MRI performed in 173 women. Each radiologist described the focal enhancement using BI-RADS terminology and assigned a final BI-RADS category. Krippendorff's α coefficient of agreement was used to asses interobserver variability. Results: All radiologists agreed on the morphology of enhancement in 183/257 (71%) lesions, yielding a substantial agreement (Krippendorff's α = 0.71). Moderate agreement was obtained for mass descriptors – shape, margins and internal enhancement – (α = 0.55, 0.51 and 0.45 respectively) and NME (non-mass enhancement) descriptors – distribution and internal enhancement – (α = 0.54 and 0.43). Overall substantial agreement was obtained for BI-RADS category assignment (α = 0.71). It was however only moderate (α = 0.38) for NME compared to mass (α = 0.80). Conclusion: Our study shows good agreement in describing mass and NME on a breast MR examination but a better agreement in predicting malignancy for mass than NME.

  9. Longitudinal, intermodality registration of quantitative breast PET and MRI data acquired before and during neoadjuvant chemotherapy: Preliminary results

    International Nuclear Information System (INIS)

    Atuegwu, Nkiruka C.; Williams, Jason M.; Li, Xia; Arlinghaus, Lori R.; Abramson, Richard G.; Chakravarthy, A. Bapsi; Abramson, Vandana G.; Yankeelov, Thomas E.

    2014-01-01

    Purpose: The authors propose a method whereby serially acquired DCE-MRI, DW-MRI, and FDG-PET breast data sets can be spatially and temporally coregistered to enable the comparison of changes in parameter maps at the voxel level. Methods: First, the authors aligned the PET and MR images at each time point rigidly and nonrigidly. To register the MR images longitudinally, the authors extended a nonrigid registration algorithm by including a tumor volume-preserving constraint in the cost function. After the PET images were aligned to the MR images at each time point, the authors then used the transformation obtained from the longitudinal registration of the MRI volumes to register the PET images longitudinally. The authors tested this approach on ten breast cancer patients by calculating a modified Dice similarity of tumor size between the PET and MR images as well as the bending energy and changes in the tumor volume after the application of the registration algorithm. Results: The median of the modified Dice in the registered PET and DCE-MRI data was 0.92. For the longitudinal registration, the median tumor volume change was −0.03% for the constrained algorithm, compared to −32.16% for the unconstrained registration algorithms (p = 8 × 10 −6 ). The medians of the bending energy were 0.0092 and 0.0001 for the unconstrained and constrained algorithms, respectively (p = 2.84 × 10 −7 ). Conclusions: The results indicate that the proposed method can accurately spatially align DCE-MRI, DW-MRI, and FDG-PET breast images acquired at different time points during therapy while preventing the tumor from being substantially distorted or compressed

  10. Interobserver variability in identification of breast tumors in MRI and its implications for prognostic biomarkers and radiogenomics

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Ashirbani, E-mail: as698@duke.edu; Grimm, Lars J., E-mail: lars.grimm@duke.edu; Harowicz, Michael, E-mail: michael.harowicz@duke.edu; Ghate, Sujata V., E-mail: sujata.ghate@duke.edu; Kim, Connie, E-mail: connie.kim@duke.edu; Walsh, Ruth, E-mail: ruth.walsh@duke.edu; Mazurowski, Maciej A., E-mail: maciej.mazurowski@duke.edu [Department of Radiology, Duke University Medical Center, 2424 Erwin Road, Suite 302, Durham, North Carolina 27705 (United States)

    2016-08-15

    Purpose: To assess the interobserver variability of readers when outlining breast tumors in MRI, study the reasons behind the variability, and quantify the effect of the variability on algorithmic imaging features extracted from breast MRI. Methods: Four readers annotated breast tumors from the MRI examinations of 50 patients from one institution using a bounding box to indicate a tumor. All of the annotated tumors were biopsy proven cancers. The similarity of bounding boxes was analyzed using Dice coefficients. An automatic tumor segmentation algorithm was used to segment tumors from the readers’ annotations. The segmented tumors were then compared between readers using Dice coefficients as the similarity metric. Cases showing high interobserver variability (average Dice coefficient <0.8) after segmentation were analyzed by a panel of radiologists to identify the reasons causing the low level of agreement. Furthermore, an imaging feature, quantifying tumor and breast tissue enhancement dynamics, was extracted from each segmented tumor for a patient. Pearson’s correlation coefficients were computed between the features for each pair of readers to assess the effect of the annotation on the feature values. Finally, the authors quantified the extent of variation in feature values caused by each of the individual reasons for low agreement. Results: The average agreement between readers in terms of the overlap (Dice coefficient) of the bounding box was 0.60. Automatic segmentation of tumor improved the average Dice coefficient for 92% of the cases to the average value of 0.77. The mean agreement between readers expressed by the correlation coefficient for the imaging feature was 0.96. Conclusions: There is a moderate variability between readers when identifying the rectangular outline of breast tumors on MRI. This variability is alleviated by the automatic segmentation of the tumors. Furthermore, the moderate interobserver variability in terms of the bounding box

  11. Mammographic density and structural features can individually and jointly contribute to breast cancer risk assessment in mammography screening

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Nielsen, Mads

    2016-01-01

    and jointly with density can improve the ability to identify screening women at increased risk of breast cancer. METHODS: The study included 121 cases and 259 age- and time matched controls based on a cohort of 14,736 women with negative screening mammograms from a population-based screening programme...... in Denmark in 2007 (followed until 31 December 2010). Mammograms were assessed using the Breast Imaging-Reporting and Data System (BI-RADS) density classification, Tabár's classification on parenchymal patterns and a fully automated texture quantification technique. The individual and combined association...

  12. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  13. Validation of a method for measuring the volumetric breast density from digital mammograms

    International Nuclear Information System (INIS)

    Alonzo-Proulx, O; Shen, S Z; Yaffe, M J; Packard, N; Boone, J M; Al-Mayah, A; Brock, K K

    2010-01-01

    The purpose of this study was to evaluate the performance of an algorithm used to measure the volumetric breast density (VBD) from digital mammograms. The algorithm is based on the calibration of the detector signal versus the thickness and composition of breast-equivalent phantoms. The baseline error in the density from the algorithm was found to be 1.25 ± 2.3% VBD units (PVBD) when tested against a set of calibration phantoms, of thicknesses 3-8 cm, with compositions equivalent to fibroglandular content (breast density) between 0% and 100% and under x-ray beams between 26 kVp and 32 kVp with a Rh/Rh anode/filter. The algorithm was also tested against images from a dedicated breast computed tomography (CT) scanner acquired on 26 volunteers. The CT images were segmented into regions representing adipose, fibroglandular and skin tissues, and then deformed using a finite-element algorithm to simulate the effects of compression in mammography. The mean volume, VBD and thickness of the compressed breast for these deformed images were respectively 558 cm 3 , 23.6% and 62 mm. The displaced CT images were then used to generate simulated digital mammograms, considering the effects of the polychromatic x-ray spectrum, the primary and scattered energy transmitted through the breast, the anti-scatter grid and the detector efficiency. The simulated mammograms were analyzed with the VBD algorithm and compared with the deformed CT volumes. With the Rh/Rh anode filter, the root mean square difference between the VBD from CT and from the algorithm was 2.6 PVBD, and a linear regression between the two gave a slope of 0.992 with an intercept of -1.4 PVBD and a correlation with R 2 = 0.963. The results with the Mo/Mo and Mo/Rh anode/filter were similar.

  14. Validation of a method for measuring the volumetric breast density from digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Alonzo-Proulx, O; Shen, S Z; Yaffe, M J [Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Packard, N; Boone, J M [UC Davis Medical Center, University of California-Davis, Sacramento, CA 95817 (United States); Al-Mayah, A; Brock, K K, E-mail: oliviera@sri.utoronto.c [University Health Network, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2010-06-07

    The purpose of this study was to evaluate the performance of an algorithm used to measure the volumetric breast density (VBD) from digital mammograms. The algorithm is based on the calibration of the detector signal versus the thickness and composition of breast-equivalent phantoms. The baseline error in the density from the algorithm was found to be 1.25 {+-} 2.3% VBD units (PVBD) when tested against a set of calibration phantoms, of thicknesses 3-8 cm, with compositions equivalent to fibroglandular content (breast density) between 0% and 100% and under x-ray beams between 26 kVp and 32 kVp with a Rh/Rh anode/filter. The algorithm was also tested against images from a dedicated breast computed tomography (CT) scanner acquired on 26 volunteers. The CT images were segmented into regions representing adipose, fibroglandular and skin tissues, and then deformed using a finite-element algorithm to simulate the effects of compression in mammography. The mean volume, VBD and thickness of the compressed breast for these deformed images were respectively 558 cm{sup 3}, 23.6% and 62 mm. The displaced CT images were then used to generate simulated digital mammograms, considering the effects of the polychromatic x-ray spectrum, the primary and scattered energy transmitted through the breast, the anti-scatter grid and the detector efficiency. The simulated mammograms were analyzed with the VBD algorithm and compared with the deformed CT volumes. With the Rh/Rh anode filter, the root mean square difference between the VBD from CT and from the algorithm was 2.6 PVBD, and a linear regression between the two gave a slope of 0.992 with an intercept of -1.4 PVBD and a correlation with R{sup 2} = 0.963. The results with the Mo/Mo and Mo/Rh anode/filter were similar.

  15. The Role of MR Imaging for the Surgical Treatment Planning of Breast Cancer: Comparison with US and the Whole-Excised Breast Histopathologic Correlation

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Choi, Hye Young; Lee, Jee Eun; Baek, Seung Yon; Sung, Sun Hee

    2009-01-01

    We wanted to evaluate the effectiveness of breast magnetic resonance (MR) imaging as a preoperative evaluation modality, as compared with ultrasonography (US) imaging, and we wanted to determine the correlation of MRI and US with using the whole-excised breast histopathology as the standard reference. (Check this and adjust it as needed.) From October 2004 to March 2008, among the 245 patients with breast cancer, 82 patients underwent modified radical mastectomy (MRM). Seven patients were excluded due to receiving neoadjuvant chemotherapy before MRI (n=4) or mammotome excision (n=2) or non-visualization of the mass on US and MR imaging (n=1). The remaining 76 breasts in 75 women (one bilateral) were examined preoperatively with MR imaging and US. On US, 42 cases showed unifocal cancer, 16 showed multifocal cancer and 18 showed multicentric breast cancers. On MRI, 39 cases showed unifocal cancer, 11 showed multifocal cancer and 26 showed multicentric breast cancers. We assessed the US findings to identify the patients who were eligible for breast conservative surgery, and then we evaluated the cancers that were treated with conversion to MRM based on the MR imaging. Histopathologic analysis revealed 45 unifocal, 10 multifocal and 22 multicentric breast cancers. Fifty five of the 76 breasts were indicated for MRM based on the US findings due to multicentric cancers (n=18), unifocal or multifocal lesions near the nipple (n=31), or unifocal or multifocal lesions showing extension towards the nipple (n=6). The remaining 21 breasts were classified as suitable for BCS on US, but 5 patients who desired MRM were excluded. Sixteen breasts were altered to MRM based on the additional findings that were suspicious for malignancy on the MR imaging. Among them, 14 (88%) breasts were adequately converted on the surgical plan to MRM based on the histopathologic verification. The remaining 2 breasts had been overestimated. Breast MRI has a significant effect for the preoperative

  16. Usefulness of 3D-VIBE method in breast dynamic MRI. Imaging parameters and contrasting effects

    International Nuclear Information System (INIS)

    Uchikoshi, Masato; Ueda, Takashi; Nishiki, Shigeo; Satou, Kouichi; Wada, Akihiko; Imaoka, Izumi; Matsuo, Michimasa

    2003-01-01

    MR imaging (MRI) has been reported to be a useful modality to characterize breast tumors and to evaluate disease extent. Contrast-enhanced dynamic MRI, in particular, allows breast lesions to be characterized with high sensitivity and specificity. Our study was designed to develop three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) techniques for the evaluation of breast tumors. First, agarose/Gd-DTPA phantoms with various concentrations of Gd-DTPA were imaged using 3D-VIBE and turbo spin echo (TSE). Second, one of the phantoms was imaged with 3D-VIBE using different flip angles. Finally, water excitation (WE) and a chemical shift-selective (CHESS) pulse were applied to the images. Each image was analyzed for signal intensity, signal-to-noise ratio (1.25*Ms/Mb) (SNR), and contrast ratio [(Ms1-Ms2)/{(Ms1+Ms2)/2}]. The results showed that 3D-VIBE provided better contrast ratios with a linear fit than TSE, although 3D-VIBE showed a lower SNR. To reach the best contrast ratio, the optimized flip angle was found to be 30 deg for contrast-enhanced dynamic study. Both WE and CHESS pulses were reliable for obtaining fat- suppressed images. In conclusion, the 3D-VIBE technique can image the entire breast area with high resolution and provide better contrast than TSE. Our phantom study suggests that optimized 3D-VIBE may be useful for the assessment of breast tumors. (author)

  17. Correlation between E-cadherin and p120 expression in invasive ductal breast cancer with a lobular component and MRI findings.

    Science.gov (United States)

    El Sharouni, Mary-Ann; Postma, Emily L; van Diest, Paul J

    2017-12-01

    Invasive breast cancer comprises a spectrum of histological changes with purely lobular cancer on one side and purely ductal cancer on the other, with many mixed lesions in between. In a previous study, we showed that in patients with any percentage lobular component at core needle biopsy, preoperative MRI leads to the detection of clinically relevant additional findings in a substantial percentage of patients, irrespective of the percentage of the lobular component. Detection of a small lobular component may however not be reproducible among pathologists. Loss of membrane expression of E-cadherin or p120 is useful biomarkers of ILC and may therefore support a more objective diagnosis. All patients diagnosed with breast cancer containing a lobular component of any percentage between January 2008 and October 2012 were prospectively offered preoperative MRI. Clinically relevant additional findings on MRI were verified by pathology evaluation. Expression patterns of E-cadherin and p120 were evaluated by immunohistochemistry on the core needle biopsy. MRI was performed in 109 patients. The percentage of lobular component was significantly increased in cases with aberrant E-cadherin or p120 expression (both p = lobular component in the core needle of their breast cancer.

  18. Mammographic breast density patterns in asymptomatic mexican women.

    Science.gov (United States)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ(2)) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns.

  19. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Garciduenas, A.L.C.; Amador, N.; Mondragon, M.S.; Hernaan, L.; Cerda-Flores, R.M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (X 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  20. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  1. Quantitative DCE-MRI for prediction of pathological complete response following neoadjuvant treatment for locally advanced breast cancer: the impact of breast cancer subtypes on the diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Drisis, Stylianos; Stathopoulos, Konstantinos; Chao, Shih-Li; Lemort, Marc [Institute Jules Bordet, Radiology Department, Brussels (Belgium); Metens, Thierry [Erasme University Hospital, Radiology Department, Brussels (Belgium); Ignatiadis, Michael [Institute Jules Bordet, Oncology Department, Brussels (Belgium)

    2016-05-15

    To assess whether DCE-MRI pharmacokinetic (PK) parameters obtained before and during chemotherapy can predict pathological complete response (pCR) differently for different breast cancer groups. Eighty-four patients who received neoadjuvant chemotherapy for locally advanced breast cancer were retrospectively included. All patients underwent two DCE-MRI examinations, one before (EX1) and one during treatment (EX2). Tumours were classified into different breast cancer groups, namely triple negative (TNBC), HER2+ and ER+/HER2-, and compared with the whole population (WP). PK parameters Ktrans and Ve were extracted using a two-compartment Tofts model. At EX1, Ktrans predicted pCR for WP and TNBC. At EX2, maximum diameter (Dmax) predicted pCR for WP and ER+/HER2-. Both PK parameters predicted pCR in WP and TNBC and only Ktrans for the HER2+. pCR was predicted from relative difference (EX1 - EX2)/EX1 of Dmax and both PK parameters in the WP group and only for Ve in the TNBC group. No PK parameter could predict response for ER+/HER-. ROC comparison between WP and breast cancer groups showed higher but not statistically significant values for TNBC for the prediction of pCR Quantitative DCE-MRI can better predict pCR after neoadjuvant treatment for TNBC but not for the ER+/HER2- group. (orig.)

  2. Occupation and mammographic density: A population-based study (DDM-Occup).

    Science.gov (United States)

    García-Pérez, Javier; Pollán, Marina; Pérez-Gómez, Beatriz; González-Sánchez, Mario; Cortés Barragán, Rosa Ana; Maqueda Blasco, Jerónimo; González-Galarzo, María Carmen; Alba, Miguel Ángel; van der Haar, Rudolf; Casas, Silvia; Vicente, Cándida; Medina, Pilar; Ederra, María; Santamariña, Carmen; Moreno, María Pilar; Casanova, Francisco; Pedraz-Pingarrón, Carmen; Moreo, Pilar; Ascunce, Nieves; García, Montse; Salas-Trejo, Dolores; Sánchez-Contador, Carmen; Llobet, Rafael; Lope, Virginia

    2017-11-01

    High mammographic density is one of the main risk factors for breast cancer. Although several occupations have been associated with breast cancer, there are no previous occupational studies exploring the association with mammographic density. Our objective was to identify occupations associated with high mammographic density in Spanish female workers. We conducted a population-based cross-sectional study of occupational determinants of high mammographic density in Spain, based on 1476 women, aged 45-68 years, recruited from seven screening centers within the Spanish Breast Cancer Screening Program network. Reproductive, family, personal, and occupational history data were collected. The latest occupation of each woman was collected and coded according to the 1994 National Classification of Occupations. Mammographic density was assessed from the cranio-caudal mammogram of the left breast using a semi-automated computer-assisted tool. Association between mammographic density and occupation was evaluated by using mixed linear regression models, using log-transformed percentage of mammographic density as dependent variable. Models were adjusted for age, body mass index, menopausal status, parity, smoking, alcohol intake, educational level, type of mammography, first-degree relative with breast cancer, and hormonal replacement therapy use. Screening center and professional reader were included as random effects terms. Mammographic density was higher, although non-statistically significant, among secondary school teachers (e β = 1.41; 95%CI = 0.98-2.03) and nurses (e β = 1.23; 95%CI = 0.96-1.59), whereas workers engaged in the care of people (e β = 0.81; 95%CI = 0.66-1.00) and housewives (e β = 0.87; 95%CI = 0.79-0.95) showed an inverse association with mammographic density. A positive trend for every 5 years working as secondary school teachers was also detected (p-value = 0.035). Nurses and secondary school teachers were the occupations with the highest

  3. Retrospective and comparative analysis of 99mTc-Sestamibi breast specific gamma imaging versus mammography, ultrasound, and magnetic resonance imaging for the detection of breast cancer in Chinese women

    International Nuclear Information System (INIS)

    Yu, Xiuyan; Hu, Guoming; Zhang, Zhigang; Qiu, Fuming; Shao, Xuan; Wang, Xiaochen; Zhan, Hongwei; Chen, Yiding; Deng, Yongchuan; Huang, Jian

    2016-01-01

    Diagnosing breast cancer during the early stage may be helpful for decreasing cancer-related mortality. In Western developed countries, mammographies have been the gold standard for breast cancer detection. However, Chinese women usually have denser and smaller-sized breasts compared to Caucasian women, which decreases the diagnostic accuracy of mammography. However, breast specific gamma imaging, a type of molecular functional breast imaging, has been used for the accurate diagnosis of breast cancer and is not influenced by breast density. Our objective was to analyze the breast specific gamma imaging (BSGI) diagnostic value for Chinese women. During a 2-year period, 357 women were diagnosed and treated at our oncology department and received BSGI in addition to mammography (MMG), ultrasound (US) and magnetic resonance imaging (MRI) for diagnostic assessment. We investigated the sensitivity and specificity of each method of detection and compared the biological profiles of the four imaging methods. A total of 357 women received a final surgical pathology diagnosis, with 168 malignant diseases (58.5 %) and 119 benign diseases (41.5 %). Of these, 166 underwent the four imaging tests preoperatively. The sensitivity of BSGI was 80.35 and 82.14 % by US, 75.6 % by MMG, and 94.06 % by MRI. Furthermore, the breast cancer diagnosis specificity of BSGI was high (83.19 % vs. 77.31 % vs. 66.39 % vs. 67.69 %, respectively). The BSGI diagnostic sensitivity for mammographic breast density in women was superior to mammography and more sensitive for non-luminal A subtypes (luminal A vs. non-luminal A, 68.63 % vs. 88.30 %). BSGI may help improve the ability to diagnose early stage breast cancer for Chinese women, particularly for ductal carcinoma in situ (DCIS), mammographic breast density and non-luminal A breast cancer

  4. Retrospective and comparative analysis of (99m)Tc-Sestamibi breast specific gamma imaging versus mammography, ultrasound, and magnetic resonance imaging for the detection of breast cancer in Chinese women.

    Science.gov (United States)

    Yu, Xiuyan; Hu, Guoming; Zhang, Zhigang; Qiu, Fuming; Shao, Xuan; Wang, Xiaochen; Zhan, Hongwei; Chen, Yiding; Deng, Yongchuan; Huang, Jian

    2016-07-11

    Diagnosing breast cancer during the early stage may be helpful for decreasing cancer-related mortality. In Western developed countries, mammographies have been the gold standard for breast cancer detection. However, Chinese women usually have denser and smaller-sized breasts compared to Caucasian women, which decreases the diagnostic accuracy of mammography. However, breast specific gamma imaging, a type of molecular functional breast imaging, has been used for the accurate diagnosis of breast cancer and is not influenced by breast density. Our objective was to analyze the breast specific gamma imaging (BSGI) diagnostic value for Chinese women. During a 2-year period, 357 women were diagnosed and treated at our oncology department and received BSGI in addition to mammography (MMG), ultrasound (US) and magnetic resonance imaging (MRI) for diagnostic assessment. We investigated the sensitivity and specificity of each method of detection and compared the biological profiles of the four imaging methods. A total of 357 women received a final surgical pathology diagnosis, with 168 malignant diseases (58.5 %) and 119 benign diseases (41.5 %). Of these, 166 underwent the four imaging tests preoperatively. The sensitivity of BSGI was 80.35 and 82.14 % by US, 75.6 % by MMG, and 94.06 % by MRI. Furthermore, the breast cancer diagnosis specificity of BSGI was high (83.19 % vs. 77.31 % vs. 66.39 % vs. 67.69 %, respectively). The BSGI diagnostic sensitivity for mammographic breast density in women was superior to mammography and more sensitive for non-luminal A subtypes (luminal A vs. non-luminal A, 68.63 % vs. 88.30 %). BSGI may help improve the ability to diagnose early stage breast cancer for Chinese women, particularly for ductal carcinoma in situ (DCIS), mammographic breast density and non-luminal A breast cancer.

  5. Diagnostic accuracy of {sup 18}F-FDG PET/CT compared with that of contrast-enhanced MRI of the breast at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Magometschnigg, Heinrich F.; Baltzer, Pascal A.; Fueger, Barbara; Helbich, Thomas H.; Weber, Michael [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Karanikas, Georgios [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna (Austria); Dubsky, Peter [Medical University of Vienna, Department of Surgery, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Department of Pathology, Vienna (Austria); Pinker, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Molecular Imaging and Therapy Service, Memorial Sloan Kettering Cancer Center, New York (United States)

    2015-10-15

    To compare the diagnostic accuracy of prone {sup 18}F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUV{sub MAX}) thresholds to differentiate malignant from benign breast lesions. A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent {sup 18}F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by {sup 18}F-FDG PET/CT and CE-MRI independently. {sup 18}F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUV{sub MAX}. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference. There were 132 malignant and 40 benign lesions; 23 lesions (13.4 %) were <10 mm. Both {sup 18}F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93 %. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91 % with both {sup 18}F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than {sup 18}F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUV{sub MAX} threshold was not helpful in differentiating benign from malignant lesions. {sup 18}F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for {sup 18}F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed

  6. Multiparametric MR imaging of the breast after augmentation and oncoplastic surgery

    International Nuclear Information System (INIS)

    Ivanov, V.; Kirova, G.

    2015-01-01

    Full text: Evaluation of breast lesions in patients after augmentation and oncoplastic surgery are difficult and uncertain with ultrasound and mammography. These two methods give us information of the lesions nature, but this information has low specificity. Morphologic MRI sequences enable to an exact assessment the nature of the lesions high sensitivity, but with low specificity. To enhance security in the evaluation of the lesions new series as DCE MRI, DWI and MRI proton spectroscopy have to be added. Teaching points: to learn how and when to use multiparametric MRI for evaluation of breast lesion after augmentation and oncoplastic surgery; to present the multiparametric MRI protocol for evaluation of malignant breast lesion after augmentation and oncoplastic surgery; to discuss the main signs differentiating benign from malignant breast lesions based on the features on multiparametric MR Inconclusive data from mammography, ultrasound and standard morphological MR series (T1,T2, FAT SAT) in the estimation of changes after augmentation and oncoplastic surgery require the use of multiparametric MRI analysis as a supplementary method for increasing sensitivity and specificity of breast MRI

  7. Epithelioid Myofibroblastoma in an Old-Male Breast: A Case Report with MRI Findings

    Directory of Open Access Journals (Sweden)

    Seyma Yildiz

    2015-01-01

    Full Text Available Myofibroblastoma of the breast (MFB is a very rare benign stromal tumor. In recent years, increase in mammographic screenings has resulted in increased diagnosis of MFB. Most cases are old males and postmenopausal women. MFB may be confused as malignant, clinically, morphologically, or by imaging. Immunohistochemistry is essential for final diagnosis in these cases. We report a case of a pathologically diagnosed MFB in an 80-year-old male patient who had coexisting prostate cancer and describe its imaging characteristics, especially magnetic resonance imaging (MRI. In this paper, histopathological and MRI findings of the MFB were discussed.

  8. AUTOMATED ANALYSIS OF CELL DENSITY IN BREAST CANCER AS AN ADDITIONAL METHOD OF INCREASING OBJECTIVITY AND ACCURACY OF BREAST CANCER PROGNOSIS

    Directory of Open Access Journals (Sweden)

    R. M. Paltuev

    2017-01-01

    Full Text Available Introduction. In the last ten years, it became obvious that on the molecular level breast cancer is a group of heterogenous tumors. The current objective of routine clinical practice of treatment prescription includes accurate disease prognosis for every individual patient and conviction that the risk of breast cancer recurrence after adjuvant hormone therapy without adjuvant chemotherapy doesn’t increase.The study objective is to evaluate how clinical use of risk associated with cell density can in practice improve prognosis of recurrence risk in patients with breast cancer after standard clinical and pathomorphological examinations.Materials and methods. The article analyzes therapy results using data from the cumulative cancer registry of breast cancer diagnosis and treatment of the N.N. Petrov National Medical Research Oncology Center in 2000–2009. The database includes information on diagnosis, treatment, and survival of 5106 patients with breast cancer. Archived material (from 2000 to 2009 from paraffin blocks of the “targeted group” for methods of molecular and genetic profiling was poured into recipient blocks, stained with corresponding antibodies such as widely used ER, PR, HER2/neu, Ki-67 markers as well as poorly studied markers: cell density, р53, CK5/6, CK14, CD4/CD8, p63, EGFR, FOXP3, AR, FOX1.Results. The study of 1118 patients with stage T1–2N0M0 breast cancer has shown that analysis of risk associated with cell density allows to predict disease outcome. Correlation between the marker and the grade of histological malignancy is more rare than for Ki-67 determined in this patient group. As a result, determination of cell density is an additional method to increase objectivity and accuracy of breast cancer prognosis.Conclusions. Automated cell density analysis for breast cancer is almost fully operator-independent which increases accuracy and objectivity of the results. Cell density in breast cancer lower than 3000

  9. PIP breast implants: rupture rate and correlation with breast cancer.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  10. Preliminary evaluation of data mining on non-masslike enhancement of breast lesions on MRI

    International Nuclear Information System (INIS)

    Tan Hongna; Li Ruimin; Wang Peihua; Tang Feng; Mao Jian; Shen Xigang; Qian Min; Gu Yajia; Su Yi; Chen Ying

    2009-01-01

    Objective: To evaluate the diagnostic values of the breast imaging reporting and data system-MRI (BI-RADS-MRI)description about non-masslike enhancement by data mining. Methods: Fifty- five patients with non-masslike enhancement lesions showed on breast contrast-enhanced MRI were evaluated using two data mining algorithms (Logistic regression and decision tree) and 10-fold cross-validation methods. Results: There were 28 malignant and 27 benign lesions. The most frequent findings of the malignant lesions were clustered ring enhancement and clumped enhancement [12 and 4 lesions, respectively; 84.2% (16/19) in decision trees, partial regression coefficients in Logistic model were 2.128 and 1.723, respectively], whereas homogenous, stippled, reticular internal and linear ductal enhancement were the most frequent findings in benign lesions [4,9,1 and 7 lesions, respectively; 72.4% (21/29) in decision tree, partial regression coefficients in Logistic model were 0.357 (homogenous), 1.861 (stippled) and 18.870(reticular), respectively]. 10-fold cross-validation indicated that decision tree (C5.0) achieved an accuracy of 69.3% with a sensitivity of 66.7% and a specificity of 71.7% in comparison to the Logistic regression model with an accuracy of 57.0%, a sensitivity of 43.3% and a specificity of 71.7%. Conclusions: The diagnosis efficacy of non-masslike enhancement interpretation according to BI-RADS-MRI is not high. It is very important to find more potential features of non-masslike enhancement to improve the diagnosis accuracy. (authors)

  11. Magnetic resonance imaging of the breast: current indications

    International Nuclear Information System (INIS)

    Lalonde, L.; David, J.; Trop, I.

    2005-01-01

    Breast magnetic resonance imaging (MRI) plays an increasing role in the management of selecting breast cancer patients. MRI is recognized as the most sensitive modality for the detection of invasive breast cancer. Several valuable clinical applications of MRI have emerged for breast cancer detection and diagnosis from clinical investigations. Breast MRI is helpful for women diagnosed with breast cancer who contemplate breast conserving surgery; it provides valuable information on the extent of the disease. MRI can also help assess for residual invasive cancer in patients who have undergone lumpectomy with positive margins at pathology. It is very reliable in differentiating scar tissue from recurrence at the lumpectomy site. MRI is also reliable in finding a breast cancer in women with axillary nodal metastases and unknown primary tumour. MRI can help to monitor the response to chemotherapy. Breast MRI could be a better screening tool than mammography in women with very high risks of developing breast cancer, such as breast cancer gene carriers and patients treated with chest radiation. Other potential uses of MRI include evaluation of the integrity of silicone breast implants and evaluation of the parenchyma in women with silicone gel implants or free injection of silicone gel. However, like any other technique, breast MRI has some drawbacks, including low-to-moderate specificity, high costs, and variability in technique and interpretation. Radiologists must have a clear understanding of valid indications and selection criteria to use this technique appropriately. (author)

  12. Integrated 18F-FDG PET/MRI in breast cancer. Early prediction of response to neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Cho, Nariya; Im, Seock-Ah; Lee, Kyung-Hun; Kim, Tae-Yong; Cheon, Gi Jeong; Park, In-Ae; Kim, Young Seon; Kwon, Bo Ra; Lee, Jung Min; Suh, Hoon Young; Suh, Koung Jin

    2018-01-01

    To explore whether integrated 18 F-FDG PET/MRI can be used to predict pathological response to neoadjuvant chemotherapy (NAC) in patients with breast cancer. Between November 2014 and April 2016, 26 patients with breast cancer who had received NAC and subsequent surgery were prospectively enrolled. Each patient underwent 18 F-FDG PET/MRI examination before and after the first cycle of NAC. Qualitative MRI parameters, including morphological descriptors and the presence of peritumoral oedema were assessed. Quantitatively, PET parameters, including maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis (TLG), and MRI parameters, including washout proportion and signal enhancement ratio (SER), were measured. The performance of the imaging parameters singly and in combination in predicting a pathological incomplete response (non-pCR) was assessed. Of the 26 patients, 7 (26.9%) exhibited a pathological complete response (pCR), and 19 (73.1%) exhibited a non-pCR. No significant differences were found between the pCR and non-pCR groups in the qualitative MRI parameters. The mean percentage reductions in TLG 30% on PET and SER on MRI were significantly greater in the pCR group than in the non-pCR group (TLG 30% -64.8 ± 15.5% vs. -25.4 ± 48.7%, P = 0.005; SER -34.6 ± 19.7% vs. -8.7 ± 29.0%, P = 0.040). The area under the receiver operating characteristic curve for the percentage change in TLG 30% (0.789, 95% CI 0.614 to 0.965) was similar to that for the percentage change in SER (0.789, 95% CI 0.552 to 1.000; P = 1.000). The specificity of TLG 30% in predicting pCR was 100% (7/7) and that of SER was 71.4% (5/7). The sensitivity of TLG 30% in predicting non-pCR was 63.2% (12/19) and that of SER was 84.2% (16/19). When the combined TLG 30% and SER criterion was applied, sensitivity was 100% (19/19), and specificity was 71.4% (5/7). 18 F-FDG PET/MRI can be used to predict non-pCR after the first cycle of NAC in patients with breast cancer

  13. High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: can underestimation be predicted?

    Energy Technology Data Exchange (ETDEWEB)

    Crystal, Pavel [Mount Sinai Hospital, University Health Network, Division of Breast Imaging, Toronto, ON (Canada); Mount Sinai Hospital, Toronto, ON (Canada); Sadaf, Arifa; Bukhanov, Karina; Helbich, Thomas H. [Mount Sinai Hospital, University Health Network, Division of Breast Imaging, Toronto, ON (Canada); McCready, David [Princess Margaret Hospital, Department of Surgical Oncology, Toronto, ON (Canada); O' Malley, Frances [Mount Sinai Hospital, Department of Pathology, Laboratory Medicine, Toronto, ON (Canada)

    2011-03-15

    To evaluate the frequency of diagnosis of high-risk lesions at MRI-guided vacuum-assisted breast biopsy (MRgVABB) and to determine whether underestimation may be predicted. Retrospective review of the medical records of 161 patients who underwent MRgVABB was performed. The underestimation rate was defined as an upgrade of a high-risk lesion at MRgVABB to malignancy at surgery. Clinical data, MRI features of the biopsied lesions, and histological diagnosis of cases with and those without underestimation were compared. Of 161 MRgVABB, histology revealed 31 (19%) high-risk lesions. Of 26 excised high-risk lesions, 13 (50%) were upgraded to malignancy. The underestimation rates of lobular neoplasia, atypical apocrine metaplasia, atypical ductal hyperplasia, and flat epithelial atypia were 50% (4/8), 100% (5/5), 50% (3/6) and 50% (1/2) respectively. There was no underestimation in the cases of benign papilloma without atypia (0/3), and radial scar (0/2). No statistically significant differences (p > 0.1) between the cases with and those without underestimation were seen in patient age, indications for breast MRI, size of lesion on MRI, morphological and kinetic features of biopsied lesions. Imaging and clinical features cannot be used reliably to predict underestimation at MRgVABB. All high-risk lesions diagnosed at MRgVABB require surgical excision. (orig.)

  14. Breast Cancer Screening (PDQ®)—Patient Version

    Science.gov (United States)

    Breast cancer screening is performed using mammogram, clinical breast exam (CBE), and MRI (magnetic resonance imaging) tests. Learn about these and other tests that have been studied to detect or screen for breast cancer in this expert-reviewed and evidence-based summary.

  15. Breast dynamic contrast enhanced MRI: fibrocystic changes presenting as a non-mass enhancement mimicking malignancy

    Directory of Open Access Journals (Sweden)

    Milosevic Zorica C.

    2017-06-01

    Full Text Available We aimed to analyse the morphokinetic features of breast fibrocystic changes (nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia presenting as a non-mass enhancement (NMEin dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI examination.

  16. Late regional density changes of the lung after radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Vagane, Randi; Danielsen, Turi; Fossa, Sophie Dorothea; Lokkevik, Erik; Olsen, Dag Rune

    2009-01-01

    Background and purpose: To investigate density changes in lung tissue, 3-4 years after postoperative adjuvant radiotherapy for breast cancer, based on dose dependence and regional differences. Material and methods: Sixty-one breast cancer patients, who had received computed tomography (CT) based postoperative radiotherapy, were included. CT scans were performed 35-51 months after start of radiotherapy. Dose information and CT scans from before and after radiotherapy were geometrically aligned in order to analyse changes in air-filled fraction (derived from CT density) as a function of dose for different regions of the lung. Results: Dose-dependent reduction of the air-filled fraction was shown to vary between the different regions of the lung. For lung tissue receiving about 50 Gy, the largest reduction in air-filled fraction was found in the cranial part of the lung. An increased air-filled fraction was observed for lung tissue irradiated to doses below 20 Gy, indicating compensatory response. Conclusions: The treatment-induced change in whole-lung density is a weighted response, involving the different regions, the irradiated volumes, and dose levels to these volumes. Simplistic models may therefore not be appropriate for describing the whole-lung dose-volume-response relationship following inhomogeneous irradiation

  17. Recurrent neural networks for breast lesion classification based on DCE-MRIs

    Science.gov (United States)

    Antropova, Natasha; Huynh, Benjamin; Giger, Maryellen

    2018-02-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) plays a significant role in breast cancer screening, cancer staging, and monitoring response to therapy. Recently, deep learning methods are being rapidly incorporated in image-based breast cancer diagnosis and prognosis. However, most of the current deep learning methods make clinical decisions based on 2-dimentional (2D) or 3D images and are not well suited for temporal image data. In this study, we develop a deep learning methodology that enables integration of clinically valuable temporal components of DCE-MRIs into deep learning-based lesion classification. Our work is performed on a database of 703 DCE-MRI cases for the task of distinguishing benign and malignant lesions, and uses the area under the ROC curve (AUC) as the performance metric in conducting that task. We train a recurrent neural network, specifically a long short-term memory network (LSTM), on sequences of image features extracted from the dynamic MRI sequences. These features are extracted with VGGNet, a convolutional neural network pre-trained on a large dataset of natural images ImageNet. The features are obtained from various levels of the network, to capture low-, mid-, and high-level information about the lesion. Compared to a classification method that takes as input only images at a single time-point (yielding an AUC = 0.81 (se = 0.04)), our LSTM method improves lesion classification with an AUC of 0.85 (se = 0.03).

  18. Background parenchymal enhancement in breast MRIs of breast cancer patients: Impact on tumor size estimation

    International Nuclear Information System (INIS)

    Baek, Ji Eun; Kim, Sung Hun; Lee, Ah Won

    2014-01-01

    Objective: To evaluate whether the degree of background parenchymal enhancement affects the accuracy of tumor size estimation based on breast MRI. Methods: Three hundred and twenty-two patients who had known breast cancer and underwent breast MRIs were recruited in our study. The total number of breast cancer cases was 339. All images were assessed retrospectively for the level of background parenchymal enhancement based on the BI-RADS criteria. Maximal lesion diameters were measured on the MRIs, and tumor types (mass vs. non-mass) were assessed. Tumor size differences between the MRI-based estimates and estimates based on pathological examinations were analyzed. The relationship between accuracy and tumor types and clinicopathologic features were also evaluated. Results: The cases included minimal (47.5%), mild (28.9%), moderate (12.4%) and marked background parenchymal enhancement (11.2%). The tumors of patients with minimal or mild background parenchymal enhancement were more accurately estimated than those of patients with moderate or marked enhancement (72.1% vs. 56.8%; p = 0.003). The tumors of women with mass type lesions were significantly more accurately estimated than those of the women with non-mass type lesions (81.6% vs. 28.6%; p < 0.001). The tumor of women negative for HER2 was more accurately estimated than those of women positive for HER2 (72.2% vs. 51.6%; p = 0.047). Conclusion: Moderate and marked background parenchymal enhancement is related to the inaccurate estimation of tumor size based on MRI. Non-mass type breast cancer and HER2-positive breast cancer are other factors that may cause inaccurate assessment of tumor size

  19. Breast MRI in pregnancy-associated breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Shin Jung; Shin, Sang Soo [Dept. of of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho [Chonnam National University Medical School, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2017-03-15

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer.

  20. Breast MRI in pregnancy-associated breast cancer

    International Nuclear Information System (INIS)

    Kim, Shin Jung; Shin, Sang Soo; Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho

    2017-01-01

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer

  1. Intratumoral and peritumoral radiomics for the pretreatment prediction of pathological complete response to neoadjuvant chemotherapy based on breast DCE-MRI.

    Science.gov (United States)

    Braman, Nathaniel M; Etesami, Maryam; Prasanna, Prateek; Dubchuk, Christina; Gilmore, Hannah; Tiwari, Pallavi; Plecha, Donna; Madabhushi, Anant

    2017-05-18

    In this study, we evaluated the ability of radiomic textural analysis of intratumoral and peritumoral regions on pretreatment breast cancer dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to predict pathological complete response (pCR) to neoadjuvant chemotherapy (NAC). A total of 117 patients who had received NAC were retrospectively analyzed. Within the intratumoral and peritumoral regions of T1-weighted contrast-enhanced MRI scans, a total of 99 radiomic textural features were computed at multiple phases. Feature selection was used to identify a set of top pCR-associated features from within a training set (n = 78), which were then used to train multiple machine learning classifiers to predict the likelihood of pCR for a given patient. Classifiers were then independently tested on 39 patients. Experiments were repeated separately among hormone receptor-positive and human epidermal growth factor receptor 2-negative (HR + , HER2 - ) and triple-negative or HER2 + (TN/HER2 + ) tumors via threefold cross-validation to determine whether receptor status-specific analysis could improve classification performance. Among all patients, a combined intratumoral and peritumoral radiomic feature set yielded a maximum AUC of 0.78 ± 0.030 within the training set and 0.74 within the independent testing set using a diagonal linear discriminant analysis (DLDA) classifier. Receptor status-specific feature discovery and classification enabled improved prediction of pCR, yielding maximum AUCs of 0.83 ± 0.025 within the HR + , HER2 - group using DLDA and 0.93 ± 0.018 within the TN/HER2 + group using a naive Bayes classifier. In HR + , HER2 - breast cancers, non-pCR was characterized by elevated peritumoral heterogeneity during initial contrast enhancement. However, TN/HER2 + tumors were best characterized by a speckled enhancement pattern within the peritumoral region of nonresponders. Radiomic features were found to strongly predict pCR independent of

  2. Effective radiation attenuation calibration for breast density: compression thickness influences and correction

    OpenAIRE

    Thomas Jerry A; Cao Ke; Heine John J

    2010-01-01

    Abstract Background Calibrating mammograms to produce a standardized breast density measurement for breast cancer risk analysis requires an accurate spatial measure of the compressed breast thickness. Thickness inaccuracies due to the nominal system readout value and compression paddle orientation induce unacceptable errors in the calibration. Method A thickness correction was developed and evaluated using a fully specified two-component surrogate breast model. A previously developed calibrat...

  3. Automated breast tissue density assessment using high order regional texture descriptors in mammography

    Science.gov (United States)

    Law, Yan Nei; Lieng, Monica Keiko; Li, Jingmei; Khoo, David Aik-Aun

    2014-03-01

    Breast cancer is the most common cancer and second leading cause of cancer death among women in the US. The relative survival rate is lower among women with a more advanced stage at diagnosis. Early detection through screening is vital. Mammography is the most widely used and only proven screening method for reliably and effectively detecting abnormal breast tissues. In particular, mammographic density is one of the strongest breast cancer risk factors, after age and gender, and can be used to assess the future risk of disease before individuals become symptomatic. A reliable method for automatic density assessment would be beneficial and could assist radiologists in the evaluation of mammograms. To address this problem, we propose a density classification method which uses statistical features from different parts of the breast. Our method is composed of three parts: breast region identification, feature extraction and building ensemble classifiers for density assessment. It explores the potential of the features extracted from second and higher order statistical information for mammographic density classification. We further investigate the registration of bilateral pairs and time-series of mammograms. The experimental results on 322 mammograms demonstrate that (1) a classifier using features from dense regions has higher discriminative power than a classifier using only features from the whole breast region; (2) these high-order features can be effectively combined to boost the classification accuracy; (3) a classifier using these statistical features from dense regions achieves 75% accuracy, which is a significant improvement from 70% accuracy obtained by the existing approaches.

  4. The Positive Outcome of MRI-Guided Vacuum Assisted Core Needle Breast Biopsies Is Not Influenced by a Prior Negative Targeted Second-Look Ultrasound.

    Science.gov (United States)

    Ferré, Romuald; AlSharif, Shaza; Aldis, Ann; Mesurolle, Benoît

    2017-11-01

    The study sought to investigate the outcome of breast magnetic resonance-guided biopsies as a function of the indication for magnetic resonance imaging (MRI), the MRI features of the lesions, and the performance or not of a targeted second-look ultrasound (SLUS) prior breast MRI-guided biopsy. We identified 158 women with MRI-detected breast lesions scheduled for MRI-guided biopsy (2007-2013). Patient demographics, performance of targeted SLUS, imaging characteristics, and subsequent pathology results were reviewed. Three biopsies were deferred, and 155 lesions were biopsied under MRI guidance (155 women; median age 55.14 years; range 27-80 years). Ninety-eight women underwent a SLUS prior to the MRI-guided biopsy (63%). Of the 155 biopsied lesions, 23 (15%) were malignant, 106 (68%) were benign, and 26 (17%) were high risk. Four of 15 surgically excised high-risk lesions were upgraded to malignancy (27%). Most of the biopsied lesions corresponded to non-mass-like enhancement (81%, 126 of 155) and most of the biopsies (52%, 81 of 155) were performed in a screening context. No demographic or MRI features were associated with malignancy. No differences were noted between the 2 subgroups (prior SLUS vs no prior SLUS) except for the presence of a synchronous carcinoma associated with a likelihood of targeted SLUS before MRI-guided biopsy (P = .001). A negative SLUS does not influence the pathology outcome of a suspicious lesion biopsied under MR guidance. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  5. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O. [University Medical Centre Mannheim, Medical Faculty Mannheim-University of Heidelberg, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Reich, C.; Kaiser, W.A. [Friedrich-Schiller-University Hospital Jena, Institute of Diagnostic and Interventional Radiology I, Jena (Germany); Dietzel, M. [Friedrich-Alexander-University Hospital Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Baltzer, P.A.T. [Medical University Vienna, Institute of Radiology and Nuclear Medicine, Vienna (Austria)

    2015-06-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  6. Predictive values of BI-RADS® magnetic resonance imaging (MRI) in the detection of breast ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Badan, Gustavo Machado; Piato, Sebastião; Roveda, Décio; Faria Castro Fleury, Eduardo de

    2016-01-01

    Purpose: The purpose of this study was to evaluate BI-RADS indicators in the detection of DCIS by MRI. Materials and methods: Prospective observational study that started in 2014 and lasted 24 months. A total of 110 consecutive patients were evaluated, who presented with suspicious or highly suspicious microcalcifications on screening mammography (BI-RADS categories 4 and 5) and underwent stereotactic-guided breast biopsy, having had an MRI scan performed prior to biopsy. Results: Altogether, 38 cases were characterized as positive for malignancy, of which 25 were DCIS and 13 were invasive ductal carcinoma cases. MRI had a sensitivity of 96%; specificity of 75.67%; positive predictive value (PPV) for DCIS detection of 57.14%; negative predictive value (NPV) in the detection of DCIS of 98.24%; and an accuracy of 80.80%. Conclusion: BI-RADS as a tool for the detection of DCIS by MRI is a powerful instrument whose sensitivity was higher when compared to that observed for mammography in the literature. Likewise, the PPV obtained by MRI was higher than that observed in the present study for mammography, and the high NPV obtained on MRI scans can provide early evidence to discourage breast biopsy in selected cases.

  7. DCE-MRI of the breast in a stand-alone setting outside a complementary strategy - results of the TK-study

    International Nuclear Information System (INIS)

    Kaiser, Clemens G.; Krammer, J.; Wasser, K.; Schoenberg, S.O.; Reich, C.; Kaiser, W.A.; Dietzel, M.; Baltzer, P.A.T.

    2015-01-01

    To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications. According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined. Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %). The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses. (orig.)

  8. Identifying Triple-Negative Breast Cancer Using Background Parenchymal Enhancement Heterogeneity on Dynamic Contrast-Enhanced MRI: A Pilot Radiomics Study.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available To determine the added discriminative value of detailed quantitative characterization of background parenchymal enhancement in addition to the tumor itself on dynamic contrast-enhanced (DCE MRI at 3.0 Tesla in identifying "triple-negative" breast cancers.In this Institutional Review Board-approved retrospective study, DCE-MRI of 84 women presenting 88 invasive carcinomas were evaluated by a radiologist and analyzed using quantitative computer-aided techniques. Each tumor and its surrounding parenchyma were segmented semi-automatically in 3-D. A total of 85 imaging features were extracted from the two regions, including morphologic, densitometric, and statistical texture measures of enhancement. A small subset of optimal features was selected using an efficient sequential forward floating search algorithm. To distinguish triple-negative cancers from other subtypes, we built predictive models based on support vector machines. Their classification performance was assessed with the area under receiver operating characteristic curve (AUC using cross-validation.Imaging features based on the tumor region achieved an AUC of 0.782 in differentiating triple-negative cancers from others, in line with the current state of the art. When background parenchymal enhancement features were included, the AUC increased significantly to 0.878 (p<0.01. Similar improvements were seen in nearly all subtype classification tasks undertaken. Notably, amongst the most discriminating features for predicting triple-negative cancers were textures of background parenchymal enhancement.Considering the tumor as well as its surrounding parenchyma on DCE-MRI for radiomic image phenotyping provides useful information for identifying triple-negative breast cancers. Heterogeneity of background parenchymal enhancement, characterized by quantitative texture features on DCE-MRI, adds value to such differentiation models as they are strongly associated with the triple-negative subtype

  9. Initial study on in vivo conductivity mapping of breast cancer using MRI.

    Science.gov (United States)

    Shin, Jaewook; Kim, Min Jung; Lee, Joonsung; Nam, Yoonho; Kim, Min-Oh; Choi, Narae; Kim, Sooyeon; Kim, Dong-Hyun

    2015-08-01

    To develop and apply a method to measure in vivo electrical conductivity values using magnetic resonance imaging (MRI) in subjects with breast cancer. A recently developed technique named MREPT (MR electrical properties tomography) together with a novel coil combination process was used to quantify the conductivity values. The overall technique was validated using a phantom study. In addition, 90 subjects were imaged (50 subjects with previously biopsy-confirmed breast tumor and 40 normal subjects), which was approved by our institutional review board (IRB). A routine clinical protocol, specifically a T2 -weighted FSE (fast spin echo) imaging data, was used for reconstruction of conductivity. By employing the coil combination, the relative error in the conductivity map was reduced from ~70% to 10%. The average conductivity values in breast cancers regions (0.89 ± 0.33S/m) was higher compared to parenchymal tissue (0.43 S/m, P conductivity compared to benign cases (0.56 S/m, n = 5) (P conductivity compared to in situ cancers (0.57 S/m) (P conductivity mapping of breast cancers is feasible using a noninvasive in vivo MREPT technique combined with a coil combination process. The method may provide a tool in the MR diagnosis of breast cancer. © 2014 Wiley Periodicals, Inc.

  10. Early Prediction and Evaluation of Breast Cancer Response to Neoadjuvant Chemotherapy Using Quantitative DCE-MRI

    Directory of Open Access Journals (Sweden)

    Alina Tudorica

    2016-02-01

    Full Text Available The purpose is to compare quantitative dynamic contrast-enhanced (DCE magnetic resonance imaging (MRI metrics with imaging tumor size for early prediction of breast cancer response to neoadjuvant chemotherapy (NACT and evaluation of residual cancer burden (RCB. Twenty-eight patients with 29 primary breast tumors underwent DCE-MRI exams before, after one cycle of, at midpoint of, and after NACT. MRI tumor size in the longest diameter (LD was measured according to the RECIST (Response Evaluation Criteria In Solid Tumors guidelines. Pharmacokinetic analyses of DCE-MRI data were performed with the standard Tofts and Shutter-Speed models (TM and SSM. After one NACT cycle the percent changes of DCE-MRI parameters Ktrans (contrast agent plasma/interstitium transfer rate constant, ve (extravascular and extracellular volume fraction, kep (intravasation rate constant, and SSM-unique τi (mean intracellular water lifetime are good to excellent early predictors of pathologic complete response (pCR vs. non-pCR, with univariate logistic regression C statistics value in the range of 0.804 to 0.967. ve values after one cycle and at NACT midpoint are also good predictors of response, with C ranging 0.845 to 0.897. However, RECIST LD changes are poor predictors with C = 0.609 and 0.673, respectively. Post-NACT Ktrans, τi, and RECIST LD show statistically significant (P < .05 correlations with RCB. The performances of TM and SSM analyses for early prediction of response and RCB evaluation are comparable. In conclusion, quantitative DCE-MRI parameters are superior to imaging tumor size for early prediction of therapy response. Both TM and SSM analyses are effective for therapy response evaluation. However, the τi parameter derived only with SSM analysis allows the unique opportunity to potentially quantify therapy-induced changes in tumor energetic metabolism.

  11. Mammographic density and histopathologic characteristics of screen-detected tumors in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Moshina, Nataliia; Ursin, Giske; Hoff, Solveig Roth; Akslen, Lars A; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2015-01-01

    High mammographic density might mask breast tumors, resulting in delayed diagnosis or missed cancers. To investigate the association between mammographic density and histopathologic tumor characteristics (histologic type, size, grade, and lymph node status) among women screened in the Norwegian Breast Cancer Screening Program. Information about 1760 screen-detected ductal carcinoma in situ (DCIS) and 7366 invasive breast cancers diagnosed among women aged 50–69 years, 1996–2010, was analyzed. The screening mammograms were classified subjectively according to the amount of fibroglandular tissue into fatty, medium dense, and dense by breast radiologists. Chi-square test was used to compare the distribution of tumor characteristics by mammographic density. Odds ratio (OR) of tumor characteristics by density was estimated by means of logistic regression, adjusting for screening mode (screen-film and full-field digital mammography), and age. Mean and median tumor size of invasive breast cancers was 13.8 and 12 mm, respectively, for women with fatty breasts, and 16.2 and 14 mm for those with dense breasts. Lymph node positive tumors were identified among 20.6% of women with fatty breasts compared with 27.2% of those with dense breasts (P < 0.001). The proportion of DCIS was significantly lower for women with fatty (15.8%) compared with dense breasts (22.0%). Women with dense breasts had an increased risk of large (OR, 1.44; 95% CI, 1.18–1.73) and lymph node positive tumors (OR, 1.26; 95% CI, 1.05–1.51) compared with women with fatty and medium dense breasts. High mammographic density was positively associated with tumor size and lymph node positive tumors

  12. Measuring the mutual effects between a CZT detector and MRI for the development of a simultaneous MBI/MRI insert

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Ashley [McMaster University (Canada); Farncombe, Troy [Hamilton Health Sciences (Canada); Noseworthy, Michael [McMaster University (Canada)

    2015-05-18

    While mammography is the gold standard for breast cancer screening, it suffers from poor sensitivity in women with dense breast tissue. Both breast MRI and molecular breast imaging (MBI) have been used as secondary imaging techniques. However, breast MRI suffers from low specificity and low sensitivity in MBI. A CZT based detector system has been developed with the goal of simultaneous MBI/MRI imaging to address the shortcomings of each modality. The performance of each modality needs to be addressed separately and together. The CZT system is comprised of four Redlen CZT modules tiled in a 2x2 array. Each module consists of 256 pixels and feature a builtin on-board ASIC and FPGA. A custom digital readout circuit board was designed to interface the four modules with a microcontroller to a PC. MR images were acquired with a 3T GE Discovery MR750 and Hologic breast coils. A gradient echo imaging sequence was used for all image acquisitions. A tissue mimicking phantom with a plastic grid insert (1 cm spacing) was used to evaluate geometric accuracy with the CZT detectors in the MRI bore. The average distance between the grid markers was 1Å 0.2cm indicating negligible geometric distortion. Field maps were generated with a uniform phantom to quantify the effect on magnetic field homogeneity. Early results indicate a significant distortion (~10ppm) in the magnetic field closest to the coil. Further analysis of the MR images will determine the extent of image quality degradation. A flood map of Tc-99m was acquired to evaluate and implement an energy correction map and a uniformity map. In the absence of a magnetic field, the mean energy resolution at 140keV was 6.3%. After fully characterizing the uniformity, geometric accuracy and sensitivity, the same metrics will be evaluated in the MRI bore.

  13. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Pierluigi, E-mail: pierluigi.rinaldi@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Giuliani, Michela, E-mail: micgiuli@yahoo.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Belli, Paolo, E-mail: pbelli@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Costantini, Melania, E-mail: mcostantini@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Romani, Maurizio, E-mail: mromani@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Distefano, Daniela, E-mail: daniela_distefano@hotmail.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bufi, Enida, E-mail: reagandus@alice.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Mule, Antonino, E-mail: amule@rm.unicatt.i [Division of Pathology and Histology, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Magno, Stefano, E-mail: smagno@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Masetti, Riccardo, E-mail: riccardo.masetti@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bonomo, Lorenzo, E-mail: lbonomo@rm.unicatt.i [Dept. of Bio-Imaging and Radiological Sciences, Catholic Univ. - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy)

    2010-08-15

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  14. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    International Nuclear Information System (INIS)

    Rinaldi, Pierluigi; Giuliani, Michela; Belli, Paolo; Costantini, Melania; Romani, Maurizio; Distefano, Daniela; Bufi, Enida; Mule, Antonino; Magno, Stefano; Masetti, Riccardo; Bonomo, Lorenzo

    2010-01-01

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  15. Role of magnetic resonance imaging in breast cancer management

    Directory of Open Access Journals (Sweden)

    Selvi Radhakrishna

    2018-01-01

    Full Text Available Magnetic resonance imaging (MRI of the breast is primarily used as a supplemental tool to breast screening with mammography or ultrasound. A breast MRI is mainly used for women who have been diagnosed with breast cancer, to help measure the size of the cancer, look for other tumors in the breast, and to check for tumors in the opposite breast. For certain women at high risk for breast cancer, a screening MRI is recommended along with a yearly mammogram. MRI is known to give some false positive results which mean more test and/or biopsies for the patient. Thus, although breast MRI is useful for women at high risk, it is rarely recommended as a screening test for women at average risk of breast cancer. Also, breast MRI does not show calcium deposits, known as micro-calcifications which can be a sign of breast cancer.

  16. Quantitative dynamic MR-mammography for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Klengel, S.; Hietschold, V.; Koehler, K.

    1997-01-01

    Problems of screening X-mammography are mainly the so-called 'dense breast', the postoperative status and suspect focal densities. Contrast enhanced MRI was hoped to further improve diagnostic specificity. Unfortunately, contrast enhancement appears in an overlapping manner in both malignant and benign lesions. A restrospective parameter analysis of dynamic early and late phase contrast enhancement showed a threshold based on a linear combination of early and late phase parameters best suited for lesion characterisation. In a prospective study this threshold offered a high specificity without loss of sensitivity in classification of suspect densities. A reduction of unnecessary operations should be possible in future relevant exclusion criteria. (orig.)

  17. Mammography combined with breast dynamic contrast-enhanced-magnetic resonance imaging for the diagnosis of early breast cancer

    Institute of Scientific and Technical Information of China (English)

    Yakun He; Guohui Xu; Jin Ren; Bin Feng; Xiaolei Dong; Hao Lu; Changjiu He

    2016-01-01

    Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the diagnosis of early breast cancer. Methods Mammography and DCE-MRI were performed for 120 patients with breast cancer (malignant, 102; benign; 18). Results The sensitivity of mammography for early diagnosis of breast cancer was 66.67%, specificity was 77.78%, and accuracy was 68.33%. The sensitivity of MRI for early diagnosis of breast cancer was 94.12%, specificity was 88.89%, and accuracy was 93.33%. However, the sensitivity of mammography combined with DCE-MRI volume imaging with enhanced water signal (VIEWS) scanning for early diagnosis of breast cancer was 97.06%, specificity was 94.44%, and accuracy was 96.67%. Conclusion Mammography combined with DCE-MRI increased the sensitivity, specificity, and accuracy of diagnosing early breast cancer.

  18. Sparse representation of multi parametric DCE-MRI features using K-SVD for classifying gene expression based breast cancer recurrence risk

    Science.gov (United States)

    Mahrooghy, Majid; Ashraf, Ahmed B.; Daye, Dania; Mies, Carolyn; Rosen, Mark; Feldman, Michael; Kontos, Despina

    2014-03-01

    We evaluate the prognostic value of sparse representation-based features by applying the K-SVD algorithm on multiparametric kinetic, textural, and morphologic features in breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). K-SVD is an iterative dimensionality reduction method that optimally reduces the initial feature space by updating the dictionary columns jointly with the sparse representation coefficients. Therefore, by using K-SVD, we not only provide sparse representation of the features and condense the information in a few coefficients but also we reduce the dimensionality. The extracted K-SVD features are evaluated by a machine learning algorithm including a logistic regression classifier for the task of classifying high versus low breast cancer recurrence risk as determined by a validated gene expression assay. The features are evaluated using ROC curve analysis and leave one-out cross validation for different sparse representation and dimensionality reduction numbers. Optimal sparse representation is obtained when the number of dictionary elements is 4 (K=4) and maximum non-zero coefficients is 2 (L=2). We compare K-SVD with ANOVA based feature selection for the same prognostic features. The ROC results show that the AUC of the K-SVD based (K=4, L=2), the ANOVA based, and the original features (i.e., no dimensionality reduction) are 0.78, 0.71. and 0.68, respectively. From the results, it can be inferred that by using sparse representation of the originally extracted multi-parametric, high-dimensional data, we can condense the information on a few coefficients with the highest predictive value. In addition, the dimensionality reduction introduced by K-SVD can prevent models from over-fitting.

  19. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Andreasen, Daniel, E-mail: dana@dtu.dk [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark); Van Leemput, Koen [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts 02129 (United States); Edmund, Jens M. [Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark)

    2016-08-15

    Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better

  20. Magnetic resonance imaging characteristics of fibrocystic change of the breast.

    Science.gov (United States)

    van den Bosch, Maurice A A J; Daniel, Bruce L; Mariano, Michelle N; Nowels, Kent N; Birdwell, Robyn L; Fong, Kathy J; Desmond, Pam S; Plevritis, Sylvia; Stables, Lara A; Zakhour, Marowan; Herfkens, Robert J; Ikeda, Debra M

    2005-07-01

    The objective of this study was to identify magnetic resonance imaging (MRI) characteristics of fibrocystic change (FCC) of the breast. Fourteen patients with a histopathologic diagnosis of solitary FCC of the breast underwent x-ray mammography and MRI of the breast. Three experienced breast imaging radiologists retrospectively reviewed the MRI findings and categorized the lesions on morphologic and kinetic criteria according to the ACR BI-RADS-MRI Lexicon. The most striking morphologic feature of fibrocystic change was nonmass-like regional enhancement found in 6 of 14 (43%) FCC lesions. Based on morphologic criteria alone, 12 of 14 (86%) lesions were correctly classified as benign. According to analysis of the time-intensity curves, 10 of 14 (71%) FCC lesions were correctly classified as benign. Although FCC has a wide spectrum of morphologic and kinetic features on MRI, it most often presents as a mass or a nonmass-like regional enhancing lesion with benign enhancement kinetics.