WorldWideScience

Sample records for mri tracer study

  1. Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data.

    Science.gov (United States)

    Buonaccorsi, Giovanni A; O'Connor, James P B; Caunce, Angela; Roberts, Caleb; Cheung, Sue; Watson, Yvonne; Davies, Karen; Hope, Lynn; Jackson, Alan; Jayson, Gordon C; Parker, Geoffrey J M

    2007-11-01

    Dynamic contrast-enhanced MRI (DCE-MRI) time series data are subject to unavoidable physiological motion during acquisition (e.g., due to breathing) and this motion causes significant errors when fitting tracer kinetic models to the data, particularly with voxel-by-voxel fitting approaches. Motion correction is problematic, as contrast enhancement introduces new features into postcontrast images and conventional registration similarity measures cannot fully account for the increased image information content. A methodology is presented for tracer kinetic model-driven registration that addresses these problems by explicitly including a model of contrast enhancement in the registration process. The iterative registration procedure is focused on a tumor volume of interest (VOI), employing a three-dimensional (3D) translational transformation that follows only tumor motion. The implementation accurately removes motion corruption in a DCE-MRI software phantom and it is able to reduce model fitting errors and improve localization in 3D parameter maps in patient data sets that were selected for significant motion problems. Sufficient improvement was observed in the modeling results to salvage clinical trial DCE-MRI data sets that would otherwise have to be rejected due to motion corruption. Copyright 2007 Wiley-Liss, Inc.

  2. Defining optimal tracer activities in pediatric oncologic whole-body {sup 18}F-FDG-PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gatidis, Sergios; Schmidt, Holger; Nikolaou, Konstantin; Schwenzer, Nina F.; Schaefer, Juergen F. [University of Tuebingen, Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen (Germany); La Fougere, Christian [University of Tuebingen, Department of Radiology, Nuclear Medicine, Tuebingen (Germany)

    2016-12-15

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined {sup 18}F-FDG-PET/MRI in pediatric oncology. 30 {sup 18}F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV{sub mean} and SUV{sub max}) as well as SUV variation (SUV{sub var}) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal {sup 18}F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV{sub mean} and SUV{sub max} were below 5 % at {sup 18}F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg {sup 18}F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg {sup 18}F-FDG or higher. Administration of {sup 18}F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered {sup 18}F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of {sup 18}F-FDG or other tracers for specific clinical

  3. Defining optimal tracer activities in pediatric oncologic whole-body "1"8F-FDG-PET/MRI

    International Nuclear Information System (INIS)

    Gatidis, Sergios; Schmidt, Holger; Nikolaou, Konstantin; Schwenzer, Nina F.; Schaefer, Juergen F.; La Fougere, Christian

    2016-01-01

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined "1"8F-FDG-PET/MRI in pediatric oncology. 30 "1"8F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV_m_e_a_n and SUV_m_a_x) as well as SUV variation (SUV_v_a_r) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal "1"8F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV_m_e_a_n and SUV_m_a_x were below 5 % at "1"8F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg "1"8F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg "1"8F-FDG or higher. Administration of "1"8F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered "1"8F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of "1"8F-FDG or other tracers for specific clinical questions have to be further established in selected

  4. Biocompatible branched copolymer nanoparticles prepared by RAFT polymerization as MRI/PET bimodal tracers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chang-Tong [Lee Kong Chian School of Medicine, Nanyang Technological University (Singapore); Tao, He; Jackson, Alexander W [Institute of Chemical and Engineering Sciences, Agency for Science Technology and Research (Singapore); Chandrasekharan, Prashant [Laboratory of Molecular Imaging, Singapore Bioimaging Consortium, Agency for Science Technology and Research (Singapore); Padmanabhan, Parasuraman [Lee Kong Chian School of Medicine, Nanyang Technological University (Singapore); Gulyás, Balázs; Halldin, Christer [Lee Kong Chian School of Medicine, Nanyang Technological University (Singapore); Karolinska Institutet, Department of Clinical Neuroscience, Stockholm (Sweden)

    2015-05-18

    Stable branched copolymer nanoparticles of varying size (Dh = 20 – 35 nm) have been developed and employed as MRI nano-sized contrast agents. RAFT polymerization has been employed to prepare these novel nanoparticles possessing DO3A macrocycles within their cores and succinimidyl ester benzoate functionalities within their coronas. It has been demonstrated that these nanoparticles can chelate gadolinium and in vitro cytotoxicity studies using HK-2 cells established their negligible toxicity profile. In vivo MRI experiments showed that these nanoparticles have a high relaxivity and a long blood retention time. Xenograft experiments further illustrated the ability of these nanoparticles to perfuse and passively accumulate in tumor cells, presumably through the enhanced EPR effect. The presence of the succinimidyl ester benzoate functionalities within the nanoparticle coronas will permit future surface modification with fluorophores or targeting moieties to generate nanoparticles to study opportunities for bimodal imaging nano-probes or active cell targeting contrast agents. The chelation with PET radioisotopes (68Ga(III) or 64Cu(II)) can afford various PET tracers.

  5. Biocompatible branched copolymer nanoparticles prepared by RAFT polymerization as MRI/PET bimodal tracers

    International Nuclear Information System (INIS)

    Yang, Chang-Tong; Tao, He; Jackson, Alexander W; Chandrasekharan, Prashant; Padmanabhan, Parasuraman; Gulyás, Balázs; Halldin, Christer

    2015-01-01

    Stable branched copolymer nanoparticles of varying size (Dh = 20 – 35 nm) have been developed and employed as MRI nano-sized contrast agents. RAFT polymerization has been employed to prepare these novel nanoparticles possessing DO3A macrocycles within their cores and succinimidyl ester benzoate functionalities within their coronas. It has been demonstrated that these nanoparticles can chelate gadolinium and in vitro cytotoxicity studies using HK-2 cells established their negligible toxicity profile. In vivo MRI experiments showed that these nanoparticles have a high relaxivity and a long blood retention time. Xenograft experiments further illustrated the ability of these nanoparticles to perfuse and passively accumulate in tumor cells, presumably through the enhanced EPR effect. The presence of the succinimidyl ester benzoate functionalities within the nanoparticle coronas will permit future surface modification with fluorophores or targeting moieties to generate nanoparticles to study opportunities for bimodal imaging nano-probes or active cell targeting contrast agents. The chelation with PET radioisotopes (68Ga(III) or 64Cu(II)) can afford various PET tracers.

  6. Delayed clearance of cerebrospinal fluid tracer from entorhinal cortex in idiopathic normal pressure hydrocephalus: A glymphatic magnetic resonance imaging study.

    Science.gov (United States)

    Eide, Per K; Ringstad, Geir

    2018-01-01

    The glymphatic system plays a key role for clearance of waste solutes from the rodent brain. We recently found evidence of glymphatic circulation in the human brain when using magnetic resonance imaging (MRI) contrast agent as cerebrospinal fluid (CSF) tracer in conjunction with multiple MRI acquisitions (gMRI). The present study explored the hypothesis that reduced glymphatic clearance in entorhinal cortex (ERC) may be instrumental in idiopathic normal pressure hydrocephalus (iNPH) dementia. gMRI acquisitions were obtained over a 24-48 h time span in cognitively affected iNPH patients and non-cognitively affected patients with suspected CSF leaks. The CSF tracer enrichment was determined as changes in normalized MRI T1 signal units. The study included 30 patients with iNPH and 8 individuals with suspected CSF leaks (i.e. reference individuals). Compared to reference individuals, iNPH patients presented with higher medial temporal lobe atrophy score and Evan's index and inferior ERC thickness. We found delayed clearance of the intrathecal CSF tracer gadobutrol from CSF, the ERC and adjacent white matter, suggesting impaired glymphatic circulation. Reduced clearance and accumulation of toxic waste product such as amyloid-β may be a mechanism behind dementia in iNPH. Glymphatic MRI (gMRI) may become a tool for assessment of early dementia.

  7. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  8. Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Bundesamt fuer Strahlenschutz (BfS), Abteilung fuer medizinischen und beruflichen Strahlenschutz, Oberschleissheim (Germany); Griebel, Juergen [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Kiessling, Fabian [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); Wenz, Frederik [University Medical Center Mannheim, University of Heidelberg, Department of Radiation Oncology, Mannheim (Germany)

    2010-08-15

    Technical developments in both magnetic resonance imaging (MRI) and computed tomography (CT) have helped to reduce scan times and expedited the development of dynamic contrast-enhanced (DCE) imaging techniques. Since the temporal change of the image signal following the administration of a diffusible, extracellular contrast agent (CA) is related to the local blood supply and the extravasation of the CA into the interstitial space, DCE imaging can be used to assess tissue microvasculature and microcirculation. It is the aim of this review to summarize the biophysical and tracer kinetic principles underlying this emerging imaging technique offering great potential for non-invasive characterization of tumour angiogenesis. In the first part, the relevant contrast mechanisms are presented that form the basis to relate signal variations measured by serial CT and MRI to local tissue concentrations of the administered CA. In the second part, the concepts most widely used for tracer kinetic modelling of concentration-time courses derived from measured DCE image data sets are described in a consistent and unified manner to highlight their particular structure and assumptions as well as the relationships among them. Finally, the concepts presented are exemplified by the analysis of representative DCE data as well as discussed with respect to present and future applications in cancer diagnosis and therapy. Depending on the specific protocol used for the acquisition of DCE image data and the particular model applied for tracer kinetic analysis of the derived concentration-time courses, different aspects of tumour angiogenesis can be quantified in terms of well-defined physiological tissue parameters. DCE imaging offers promising prospects for improved tumour diagnosis, individualization of cancer treatment as well as the evaluation of novel therapeutic concepts in preclinical and early-stage clinical trials. (orig.)

  9. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Han, Hongbin; Chen, Deji

    2017-01-01

    Background This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. Material/Methods Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. Results Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. Conclusions Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future. PMID:28866708

  10. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging.

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Chen, Deji; Han, Hongbin

    2017-09-03

    BACKGROUND This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. MATERIAL AND METHODS Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. RESULTS Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. CONCLUSIONS Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future.

  11. Novel tracer for radiation treatment planning; Welche neuen PET-Tracer braucht die Strahlentherapie?

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzenboeck, S.; Krause, B.J. [Rostock Univ. (Germany). Klinik fuer Nuklearmedizin; Herrmann, K.; Gaertner, F.; Souvatzoglou, M. [Technische Univ. Muenchen (Germany). Klinik fuer Nuklearmedizin; Klaesner, B. [Klinikum Bogenhausen, Muenchen (Germany). Inst. fuer Radiologie und Nuklearmedizin

    2011-07-15

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [{sup 18}F]Fluorothymidine ([{sup 18}F]FLT) as marker of proliferation, [{sup 18}F]Fluoromisonidazole ([{sup 18}F]FMISO) and [{sup 18}F]Fluoroazomycin-Arabinoside ([{sup 18}F]FAZA) as tracer of hypoxia, [{sup 18}F]Fluoroethyltyrosine ([{sup 18}F]FET) and [{sup 11}C]Methionine for brain tumour imaging, [{sup 68}Ga]DOTATOC for somatostatin receptor imaging, [{sup 18}F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  12. Low dose caffeine as a salivary tracer for the determination of gastric water emptying in fed and fasted state: A MRI validation study.

    Science.gov (United States)

    Sager, Maximilian; Jedamzik, Philipp; Merdivan, Simon; Grimm, Michael; Schneider, Felix; Kromrey, Marie-Luise; Hasan, Mahmoud; Oswald, Stefan; Kühn, Jens; Koziolek, Mirko; Weitschies, Werner

    2018-06-01

    Improving our knowledge about human gastrointestinal physiology and its impact on oral drug delivery is crucial for the development of new therapies and effective drug delivery systems. The aim of this study was to develop an in vivo tool to determine gastric emptying of water by administration of a caffeine as a tracer substance followed by subsequent saliva caffeine analysis. For this purpose, 35 mg of caffeine were given to six healthy volunteers after a 10 h overnight together with 240 mL of tap water either on a fasted stomach or 30 min after the high-caloric, high-fat breakfast recommended for bioavailability/bioequivalence (BA/BE) studies. Caffeine was administered in form of an ice capsule in order to omit the contamination of the oral cavity with caffeine. Parallel to saliva sampling, magnetic resonance imaging (MRI) was applied in order to validate this novel approach. After administration of the ice capsule, MRI measurements were performed every 2 min for the first 20 min followed by further measurements after 25, 30, 35, 40, 50 and 60 min. Saliva samples were collected always 1 min after the MRI measurement in supine position in the MRI scanner and continued for further 240 min. The caffeine concentration in saliva was quantified after liquid-liquid extraction by a validated HPLC/MS-MS method. The obtained MRI data revealed a fast emptying of the co-administered water within 10 to 50 min in the fasted state and likewise in the fed state. Salivary caffeine kinetics showed a C max from 150 to 400 ng/mL with a t max from 20 to 90 min. MRI data were normalized by setting the maximum emptied volume to 100% and the salivary caffeine kinetics were normalized by setting C max to 100%. In order to compare the results obtained by the MRI and the saliva method, the normalized data for each volunteer was correlated based on a linear regression. In the fasted state the mean slope for six comparisons was 0.9114 ± 0.1500 and the mean

  13. SPECT/CT versus MRI in patients with nonspecific pain of the hand and wrist - a pilot study

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Buerkert, Alexander; Schleich, Florian S.; Strobel, Klaus; Veit-Haibach, Patrick; Schuerch, Maja; Hug, Urs; Wartburg, Urs von

    2012-01-01

    Hand and wrist pain is a diagnostic challenge for hand surgeons and radiologists due to the complex anatomy of the involved small structures. The American College of Radiology recommends MRI as the study of choice in patients with chronic wrist pain if radiographs are negative. Lately, state-of-the-art SPECT/CT systems have been introduced and may help in the diagnosis of this selected indication. This retrospective study included 21 patients with nonspecific pain of the hand/wrist. The diagnosis of nonspecific wrist pain was made by the referring hand surgeon based on patient history, clinical examination, plain radiography and clinical guidelines. All patients received planar early-phase imaging and late-phase SPECT/CT imaging as well as MRI. Lesions were divided into major (causative) and minor (not causative) pathologies according to clinical follow-up. Furthermore, oedema-like bone marrow changes seen on MRI were compared with focally increased tracer uptake seen on SPECT/CT images. MRI yielded a quite high sensitivity (0.86), but a low specificity (0.20). In contrast, SPECT/CT yielded a high specificity (1.00) and a low sensitivity (0.71). Oedema-like bone marrow changes were detected in 15 lesions in 11 patients. In ten lesions with bone marrow oedema on MRI, foci of elevated tracer uptake were detected on SPECT/CT. Overall, MRI was more sensitive, but SPECT/CT was more specific in the evaluation of causative pathologies. In this initial comparison, SPECT/CT showed higher specificity than MRI in the evaluation of causative pathologies in patients with nonspecific wrist pain. However, MRI was more sensitive. Thus, SPECT/CT was shown to be a useful problem-solving tool in the diagnostic work-up of these patients. (orig.)

  14. Tracer a application in marine outfall studies

    International Nuclear Information System (INIS)

    Genders, S.

    1979-01-01

    The applicability of radioactive and fluorescent tracers for field studies to predict or investigate waste water transport and dispersion from marine outfalls is evaluated. The application of either instantaneous or continuous tracer release, 'in situ' detection of tracers and data processing are considered. The necessity of a combined use of tracer techniques and conventional hydrographic methods for a statistical prediction of transport and dillution of waste water are pointed out. A procedure to determine an outlet distance from the coast, which satisfy bathing water criteria is outlined. (M.A.) [pt

  15. Measuring and modeling of a three-dimensional tracer transport in a planted soil column

    Science.gov (United States)

    Schroeder, N.; Javaux, M.; Haber-Pohlmeier, S.; Pohlmeier, A. J.; Huber, K.; Vereecken, H.; Vanderborght, J.

    2013-12-01

    Water flow from soil to root is driven by the plant transpiration and an important component of the hydrological cycle. The model R-SWMS combines three-dimensional (3D) water flow and solute transport in soil with a detailed description of root structure in three dimensions [1,2]. This model offers the possibility to calculate root water and solute uptake and flow within the roots, which enables explicit studies with respect to the distribution of water and solutes around the roots as well as local processes at the root-soil interface. In this study, we compared measured data from a tracer experiment using Magnetic Resonance Imaging (MRI) with simulations in order to assess the distribution and magnitude of the water uptake of a young lupine plant. An aqueous solution of the Gadolinium-complex (Gd-DTPA2-) was chosen as a tracer, as it behaves conservatively and is ideally suited for MRI. Water flow in the soil towards the roots can thus be visualized by following the change in tracer concentrations over time. The data were obtained by MRI, providing high resolution 3D images of the tracer distribution and root architecture structures by using a spin echo pulse sequence, which is strongly T1- weighted to be tracer sensitive [3], and T2 -weighted for root imaging [4]. This experimental setup was simulated using the 3D high-resolution numerical model R-SWMS. The comparison between MRI data and the simulations showed extensive effects of root architecture parameters on solute spreading. Although the results of our study showed the strength of combining non-invasive measurements and 3D modeling of solute and water flow in soil-root systems, where the derivation of plant hydraulic parameters such as axial and radial root conductivities is possible, current limitations were found with respect to MRI measurements and process description. [1] Javaux, M., T. Schröder, J. Vanderborght, and H. Vereecken (2008), Use of a Three-Dimensional Detailed Modeling Approach for

  16. Bromide as a tracer for studying water movement and nitrate displacement in soils: comparison with stable isotope tracers

    International Nuclear Information System (INIS)

    Russow, R.; Knappe, S.

    1999-01-01

    Tracers are an ideal means of studying water movement and associated nitrate displacement. Often bromide is preferred as a tracer because it is considered a representative tracer for water and because, being a conservative tracer (i.e. not involved in chemical and biological soil processes), it can be used for studying anion transport in soils. Moreover, it is less expensive and easier to measure than the stable isotopes deuterium and 15 N. Its great advantage over radioactive tracers (e.g. tritium), which outweighs their extreme sensitivity and ease of measurement and which it has in common with stable isotopes, is that it does not require radiation protection measures. However, there are also constraints on the use of bromide as a tracer in soil/water/plant systems. Our own studies on different soils using D 2 O, bromide and [ 15 N]-nitrate in lysimeters suggest that the above assumptions on bromide tracers need not always be valid under conditions as they prevail in biologically active soils. As the present paper shows, these studies permit a good assessment of the possibilities and limits to these tracers [de

  17. Novel tracer for radiation treatment planning

    International Nuclear Information System (INIS)

    Schwarzenboeck, S.; Krause, B.J.; Herrmann, K.; Gaertner, F.; Souvatzoglou, M.; Klaesner, B.

    2011-01-01

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [ 18 F]Fluorothymidine ([ 18 F]FLT) as marker of proliferation, [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) and [ 18 F]Fluoroazomycin-Arabinoside ([ 18 F]FAZA) as tracer of hypoxia, [ 18 F]Fluoroethyltyrosine ([ 18 F]FET) and [ 11 C]Methionine for brain tumour imaging, [ 68 Ga]DOTATOC for somatostatin receptor imaging, [ 18 F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  18. WE-FG-206-06: Dual-Input Tracer Kinetic Modeling and Its Analog Implementation for Dynamic Contrast-Enhanced (DCE-) MRI of Malignant Mesothelioma (MPM)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Rimner, A; Hayes, S; Hunt, M; Deasy, J; Zauderer, M; Rusch, V; Tyagi, N [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To use dual-input tracer kinetic modeling of the lung for mapping spatial heterogeneity of various kinetic parameters in malignant MPM Methods: Six MPM patients received DCE-MRI as part of their radiation therapy simulation scan. 5 patients had the epitheloid subtype of MPM, while one was biphasic. A 3D fast-field echo sequence with TR/TE/Flip angle of 3.62ms/1.69ms/15° was used for DCE-MRI acquisition. The scan was collected for 5 minutes with a temporal resolution of 5-9 seconds depending on the spatial extent of the tumor. A principal component analysis-based groupwise deformable registration was used to co-register all the DCE-MRI series for motion compensation. All the images were analyzed using five different dual-input tracer kinetic models implemented in analog continuous-time formalism: the Tofts-Kety (TK), extended TK (ETK), two compartment exchange (2CX), adiabatic approximation to the tissue homogeneity (AATH), and distributed parameter (DP) models. The following parameters were computed for each model: total blood flow (BF), pulmonary flow fraction (γ), pulmonary blood flow (BF-pa), systemic blood flow (BF-a), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), fractional interstitial volume (vi), extraction fraction (E), volume transfer constant (Ktrans) and efflux rate constant (kep). Results: Although the majority of patients had epitheloid histologies, kinetic parameter values varied across different models. One patient showed a higher total BF value in all models among the epitheloid histologies, although the γ value was varying among these different models. In one tumor with a large area of necrosis, the TK and ETK models showed higher E, Ktrans, and kep values and lower interstitial volume as compared to AATH and DP and 2CX models. Kinetic parameters such as BF-pa, BF-a, PS, Ktrans values were higher in surviving group compared to non-surviving group across most models. Conclusion: Dual-input tracer

  19. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  20. Sistem Pre Kompilasi Data Tracer Studi Online Ditjen Belmawa Ristekdikti (Studi Kasus: Politeknik Harapan Bersama

    Directory of Open Access Journals (Sweden)

    Very Kurnia Bakti

    2017-01-01

    Full Text Available Tracer studi merupakan salah satu upaya yang diharapkan dapat menyediakan informasi untuk mengevaluasi hasil pendidikan di Politeknik Harapan Bersama dari kuisioner yang diberikan kepada alumni. Kegiatan tracer studi ini sudah dilaksanakan secara online, namun masih terdapat kendala pada bagian sistem yang digunakan saat ini, hal tersebut menyebabkan Politeknik Harapan Bersama tidak dapat melaporkan / mengunggah hasil tracer studi kepada Ditjen Belmawa Ristekdikti, dimana form kuisioner dan data export tracer studi yang dihasilkan berbeda dengan kebutuhan seperti yang tercantum pada surat edaran No. 313/B/SE/2016 tentang pelaksanaan tracer studi di tingkat perguruan tinggi. Mengingat pentingnya tracer studi sebagai umpan balik bagi Politeknik Harapan Bersama, maka perlu solusi untuk mengatasi kekurangan sistem ini. Dengan merubah sistem yang ada dengan sistem tracer studi yang baru merupakan solusi yang tepat dalam permasalahan ini. Sistem tracer studi yang baru mampu menghasilkan data tracer studi alumni dan pengisian form kuisioner sesuai dengan standar Ditjen Belmawa Ristekdikti yang dapat diunggah sistem tracer studi ristekdikti.

  1. Radioisotope tracers in industrial flow studies

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    The scope of radioisotope tracer work carried out by ANSTO has involved most sectors of Australian industry including iron and steel coal, chemical, petrochemical, natural gas, metallurgical, mineral, power generation, liquified air plant, as well as port authorities, water and sewerage instrumentalities, and environmental agencies. A major class of such studies concerns itself with flow and wear studies involving industrial equipment. Some examples are discussed which illustrate the utility of radioisotope tracer techniques in these applications

  2. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  3. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    Science.gov (United States)

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose

  4. Conspicuity of FDG-aid osseous lesions on PET/MRI versus PET/CT: A quantitative and visual analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fraum, Tyler J.; Fowler, Kathryn J.; Mcconathy, Jonathan [Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis (United States)

    2016-09-15

    Because standard MRI-based attenuation correction (AC) does not account for the attenuation of photons by cortical bone, PET/MRI may have reduced sensitivity for FDG-avid focal bone lesions (FFBLs). This study evaluates whether MRI-based AC compromises detection of FFBLs, by comparing their conspicuity both quantitatively and qualitatively on PET/MRI versus PET/CT. One hundred ninety general oncology patients underwent whole-body PET/CT followed by whole-body PET/MRI, utilizing the same FDG dose. Thirteen patients with a total of 50 FFBLs were identified. Using automated contouring software, a volumetric contour was generated for each FFBL. Adjacent regions of normal background bone (BB) were selected manually. For each contour, SUV-max and SUV-mean were determined. Lesion-to-background SUV ratios served as quantitative metrics of conspicuity. Additionally, two blinded readers evaluated the relative conspicuity of FFBLs on PET images derived from MRI-based AC versus CT-based AC. Visibility of an anatomic correlate for FFBLs on the corresponding CT and MR images was also assessed. SUV-mean was lower on PET/MRI for both FFBLs (-6.5 %, p = 0.009) and BB (-20.5 %, p < 0.001). SUV-max was lower on PET/MRI for BB (-14.2 %, p = 0.002) but not for FFBLs (-6.2 %, p = 0.068). The ratio of FFBL SUV-mean to BB SUV-mean was higher for PET/MRI (+29.5 %, p < 0.001). Forty of 50 lesions (80 %) were visually deemed to be of equal or greater conspicuity on PET images derived from PET/MRI. Thirty-five of 50 FFBLs (70 %) had CT correlates, while 40/50 FFBLs (80 %) had a correlate on at least one MRI sequence. The mean interval from tracer administration to imaging was longer (p < 0.001) for PET/MRI (127 v. 62 min). Both FFBLs and BB had lower mean SUVs on PET/MRI than PET/CT. This finding was likely in part due to differences in the handling of cortical bone by MRI-based AC versus CT-based AC. Despite this systematic bias, FFBLs had greater conspicuity on PET/MRI

  5. Parameter Optimization for Quantitative Signal-Concentration Mapping Using Spoiled Gradient Echo MRI

    Directory of Open Access Journals (Sweden)

    Gasser Hathout

    2012-01-01

    Full Text Available Rationale and Objectives. Accurate signal to tracer concentration maps are critical to quantitative MRI. The purpose of this study was to evaluate and optimize spoiled gradient echo (SPGR MR sequences for the use of gadolinium (Gd-DTPA as a kinetic tracer. Methods. Water-gadolinium phantoms were constructed for a physiologic range of gadolinium concentrations. Observed and calculated SPGR signal to concentration curves were generated. Using a percentage error determination, optimal pulse parameters for signal to concentration mapping were obtained. Results. The accuracy of the SPGR equation is a function of the chosen MR pulse parameters, particularly the time to repetition (TR and the flip angle (FA. At all experimental values of TR, increasing FA decreases the ratio between observed and calculated signals. Conversely, for a constant FA, increasing TR increases this ratio. Using optimized pulse parameter sets, it is possible to achieve excellent accuracy (approximately 5% over a physiologic range of concentration tracer concentrations. Conclusion. Optimal pulse parameter sets exist and their use is essential for deriving accurate signal to concentration curves in quantitative MRI.

  6. Bromide as a tracer for studying water movement and nitrate displacement in soils: comparison with stable isotope tracers; Bromid als Tracer zur Untersuchung der Wasserbewegung und der Nitratverlagerung in Boeden: Vergleich mit stabilisotopen Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Russow, R.; Knappe, S. [UFZ - Umweltforschungszentrum Leipzig-Halle GmbH, Bad Lauchstaedt (Germany). Sektion Bodenforschung

    1999-02-01

    Tracers are an ideal means of studying water movement and associated nitrate displacement. Often bromide is preferred as a tracer because it is considered a representative tracer for water and because, being a conservative tracer (i.e. not involved in chemical and biological soil processes), it can be used for studying anion transport in soils. Moreover, it is less expensive and easier to measure than the stable isotopes deuterium and {sup 15}N. Its great advantage over radioactive tracers (e.g. tritium), which outweighs their extreme sensitivity and ease of measurement and which it has in common with stable isotopes, is that it does not require radiation protection measures. However, there are also constraints on the use of bromide as a tracer in soil/water/plant systems. Our own studies on different soils using D{sub 2}O, bromide and [{sup 15}N]-nitrate in lysimeters suggest that the above assumptions on bromide tracers need not always be valid under conditions as they prevail in biologically active soils. As the present paper shows, these studies permit a good assessment of the possibilities and limits to these tracers. [Deutsch] Fuer die Untersuchung der Wasserbewegung sowie der daran gekoppelten Nitrat-Verlagerung ist der Einsatz von Tracern das Mittel der Wahl. Dabei wird Bromid als Tracer haeufig bevorzugt, da es allgemein als ein repraesentativer Tracer fuer Wasser und als konservativer Tracer (nicht involviert in chemische und biologische Bodenprozesse) zur Untersuchung des Anionentransportes in Boeden angesehen wird und es gegenueber den stabilen Isotopen Deuterium und {sup 15}N billiger und einfacher zu bestimmen ist. Gegenueber den radioaktiven Tracern (z.B. Tritium), die zwar sehr empfindlich und einfach messbar sind, besteht der grosse Vorteil, dass, wie bei den stabilen Isotopen, keine Strahlenschutzmassnahmen ergriffen werden muessen. Es gibt jedoch auch einschraenkende Hinweise fuer die Verwendung von Bromid als Tracer im System Boden

  7. Tracer theory

    International Nuclear Information System (INIS)

    Margrita, R.

    1988-09-01

    Tracers are used in many fields of science to investigate mass transfer. The scope of tracers applications in Service of Applications Radioisotopes (S.A.R.-France) is large and concerns natural and industrial systems such as Sciences of earth: hydrology - civil engineering - Sedimentology - environmental studies. Industrial field: chemical engineering - mechanical engineering. A general tracer methodology has been developed in our laboratories from these different applications fields and this paper shows these different points of view in using tracers; our wish is that the methods used in an experimental field can be employed in an another one

  8. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  9. Rate equations for tracer studies in recirculating reactors

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J [Columbia Univ., New York (USA). Dept. of Chemical Engineering

    1974-10-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved.

  10. Rate equations for tracer studies in recirculatinng reactors

    International Nuclear Information System (INIS)

    Happel, J.

    1974-01-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved. (auth.)

  11. Circulation of cerebrospinal fluid. Comparative study of various tracers

    International Nuclear Information System (INIS)

    Bok, B.; Thebault, B.; Cavailloles, F.; Aboulker, J.

    1977-01-01

    The dynamics of cerebrospinal fluid in the spinal subarachnoid space is studied by gammamyelography. There are still controversies about the ideal properties of the tracer to be used. The influence of the tracer's molecular weight on the kinetic of ascent in the medullar cerebrospinal fluid with a view to rating the criterias for choice of an available radiopharmaceutical was evaluated. Three compounds injected simultaneously through a lombar puncture were compared: indium 111 labelled transferrin, iodine 131 labelled human serum albumin and technetium 99m labelled diethylenetriaminepentaacetic acid. The individual stability of the compounds and a possible interference between them was investigated especially by electrophoretic technics. A spectrometric study showed that it is possible to simultaneously identify and count each of the isotopes included in the mixture on the detector device: an hybrid scanner. The comparison of linear activity profils collected on phantoms and on ten patients showed a similar fate of the three compounds during the first hours of the investigation studying the ascent of tracers into basal cisterns either in normal or pathological patients. It is therefore concluded that molecular weight does not influence in a detectable manner the spinal C.S.F. kinetics of the radiopharmaceuticals. This allows the use of the most convenient and best tolerated tracer from the dosimetric and toxicological stand point [fr

  12. Modeling Dynamic Contrast-Enhanced MRI Data with a Constrained Local AIF

    DEFF Research Database (Denmark)

    Duan, Chong; Kallehauge, Jesper F.; Pérez-Torres, Carlos J

    2018-01-01

    PURPOSE: This study aims to develop a constrained local arterial input function (cL-AIF) to improve quantitative analysis of dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) data by accounting for the contrast-agent bolus amplitude error in the voxel-specific AIF. PROCEDURES....... RESULTS: When the data model included the cL-AIF, tracer kinetic parameters were correctly estimated from in silico data under contrast-to-noise conditions typical of clinical DCE-MRI experiments. Considering the clinical cervical cancer data, Bayesian model selection was performed for all tumor voxels...

  13. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    International Nuclear Information System (INIS)

    Anazodo, Udunna; Kewin, Matthew; Finger, Elizabeth; Thiessen, Jonathan; Hadway, Jennifer; Butler, John; Pavlosky, William; Prato, Frank; Thompson, Terry; St Lawrence, Keith

    2015-01-01

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  14. Preliminary evaluation of MRI-derived input function for quantitative measurement of glucose metabolism in an integrated PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Anazodo, Udunna; Kewin, Matthew [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Finger, Elizabeth [Department of Clinical Neurological Sciences, Western University, London, Ontario (Canada); Thiessen, Jonathan; Hadway, Jennifer; Butler, John [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada); Pavlosky, William [Diagnostic Imaging, St Joseph' s Health Care, London, Ontario (Canada); Prato, Frank; Thompson, Terry; St Lawrence, Keith [Lawson Health Research Institute, Department of Medical Biophysics, Western University, London, Ontario (Canada)

    2015-05-18

    PET semi-quantitative methods such as relative uptake value can be robust but offer no biological information and do not account for intra-subject variability in tracer administration or clearance. Simultaneous multimodal measurements that combine PET and MRI not only permit crucial multiparametric measurements, it provides means of applying tracer kinetic modelling without the need for serial arterial blood sampling. In this study we adapted an image-derived input function (IDIF) method to improve characterization of glucose metabolism in an ongoing dementia study. Here we present preliminary results in a small group of frontotemporal dementia patients and controls. IDIF was obtained directly from dynamic PET data guided by regions of interest drawn on carotid vessels on high resolution T1-weighted MR Images. IDIF was corrected for contamination of non-arterial voxels. A validation of the method was performed in a porcine model in a PET-CT scanner comparing IDIF to direct arterial blood samples. Metabolic rate of glucose (CMRglc) was measured voxel-by-voxel in gray matter producing maps that were compared between groups. Net influx rate (Ki) and global mean CMRglc are reported. A good correlation (r = 0.9 p<0.0001) was found between corrected IDIF and input function measured from direct arterial blood sampling in the validation study. In 3 FTD and 3 controls, a trend towards hypometabolism was found in frontal, temporal and parietal lobes similar to significant differences previously reported by other groups. The global mean CMRglc and Ki observed in control subjects are in line with previous reports. In general, kinetic modelling of PET-FDG using an MR-IDIF can improve characterization of glucose metabolism in dementia. This method is feasible in multimodal studies that aim to combine PET molecular imaging with MRI as dynamic PET can be acquired along with multiple MRI measurements.

  15. Deuterium used as artificial tracer in column studies under saturated water flow conditions

    Science.gov (United States)

    Koeniger, P.; Geiges, M.; Leibundgut, Ch.

    2003-04-01

    In contrast to numerous investigations using deuterium as an environmental tracer, hydrological investigations with deuterium-labelled water are rather rare. Currently applications in groundwater studies are restricted due to increasing costs of spiking large water quantities but an application as intelligent tracer might be of advantage especially in combination with other tracers and under distinct environmental conditions. Therefore deuterium was applied as artificial tracer in column experiments that are well proved as a tool to characterise tracer behaviour in recent studies. Deuterium was tested in comparison to the more familiar conservative tracer fluorescein. Varying experimental conditions, e.g. column length (0.5, 1.0, 1.5 m), initial tracer concentration (0.01, 0.02, 0.2 mg) and flow velocity (1.5 to 6.0 m/d) were used to investigate tracer behaviour under saturated water flow conditions. Deuterium was analysed using an H/Device with chrome reduction connected to an isotope ratio mass spectrometer and expressed in relative concentrations [per mill V-SMOW]. Theoretical tracer breakthrough curves were calculated using a one dimensional dispersion model. The results indicate higher mean transport velocities and smaller dispersion for deuterium in all experiments. Due to different molecule properties that also determine the interaction of soil substrate and tracer, deuterium indicates a more conservative transport behaviour. Deuterium is non-toxic, completely soluble, chemically and biologically stable and not subject to light-influenced decay. Furthermore, it shows promise for investigations of water flow in the unsaturated zone, and of interactions of water in soil-plant-atmosphere systems. A further discussion of problems, together with possibilities for applying deuterium as an artificial tracer, will be presented.

  16. An experimental study of tracers for labelling of injection gas in oil reservoirs

    International Nuclear Information System (INIS)

    Dugstad, Oe.

    1992-01-01

    This work demonstrates the feasibility of the PMCP and PMCH as tracers in field experiments. These compounds have properties which make them as well suited for well to well studies as the more common tracers CH 3 T and 85 Kr. In an injection project carried out at the Gullfaks field in the North Sea the two PFCs verified communication between wells. This implies communication between different geological layers in the reservoir and also communication across faults within the same layers. Laboratory studies carried out have focused on the retention of the tracers in dynamic flooding experiments under conditions comparable with those in the petroleum reservoirs. Simultaneous injection of a variety of tracers has shown individual variations in tracer retention which are caused by important reservoir parameters as fluid saturation and rock properties. By proper design of field injection programs the tracers response may therefore be used to estimate fluid saturation if actual rock properties are known. 45 refs., 20 figs., 13 tabs

  17. Current status and future role of brain PET/MRI in clinical and research settings

    Energy Technology Data Exchange (ETDEWEB)

    Werner, P.; Barthel, H.; Sabri, O. [University Hospital Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Drzezga, A. [University Hospital Cologne, Department of Nuclear Medicine, Koeln (Germany)

    2015-01-09

    Hybrid PET/MRI systematically offers a complementary combination of two modalities that has often proven itself superior to the single modality approach in the diagnostic work-up of many neurological and psychiatric diseases. Emerging PET tracers, technical advances in multiparametric MRI and obvious workflow advantages may lead to a significant improvement in the diagnosis of dementia disorders, neurooncological diseases, epilepsy and neurovascular diseases using PET/MRI. Moreover, simultaneous PET/MRI is well suited to complex studies of brain function in which fast fluctuations of brain signals (e.g. related to task processing or in response to pharmacological interventions) need to be monitored on multiple levels. Initial simultaneous studies have already demonstrated that these complementary measures of brain function can provide new insights into the functional and structural organization of the brain. (orig.)

  18. Current status and future role of brain PET/MRI in clinical and research settings

    International Nuclear Information System (INIS)

    Werner, P.; Barthel, H.; Sabri, O.; Drzezga, A.

    2015-01-01

    Hybrid PET/MRI systematically offers a complementary combination of two modalities that has often proven itself superior to the single modality approach in the diagnostic work-up of many neurological and psychiatric diseases. Emerging PET tracers, technical advances in multiparametric MRI and obvious workflow advantages may lead to a significant improvement in the diagnosis of dementia disorders, neurooncological diseases, epilepsy and neurovascular diseases using PET/MRI. Moreover, simultaneous PET/MRI is well suited to complex studies of brain function in which fast fluctuations of brain signals (e.g. related to task processing or in response to pharmacological interventions) need to be monitored on multiple levels. Initial simultaneous studies have already demonstrated that these complementary measures of brain function can provide new insights into the functional and structural organization of the brain. (orig.)

  19. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    Science.gov (United States)

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  20. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  1. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  2. Hanford facilities tracer study report (315 Water Treatment Facility)

    International Nuclear Information System (INIS)

    Ambalam, T.

    1995-01-01

    This report presents the results and findings of a tracer study to determine contact time for the disinfection process of 315 Water Treatment Facility that supplies sanitary water for the 300 Area. The study utilized fluoride as the tracer and contact times were determined for two flow rates. Interpolation of data and short circuiting effects are also discussed. The 315 Water Treatment Facility supplies sanitary water for the 300 Area to various process and domestic users. The Surface Water Treatment Rule (SWTR), outlined in the 1986 Safe Drinking Water Act Amendments enacted by the EPA in 1989 and regulated by the Washington State Department of Health (DOH) in Section 246-290-600 of the Washington Administrative Code (WAC), stipulates filtration and disinfection requirements for public water systems under the direct influence of surface water. The SWTR disinfection guidelines require that each treatment system achieves predetermined inactivation ratios. The inactivation by disinfection is approximated with a measure called CxT, where C is the disinfectant residual concentration and T is the effective contact time of the water with the disinfectant. The CxT calculations for the Hanford water treatment plants were derived from the total volume of the contact basin(s). In the absence of empirical data to support CxT calculations, the DOH determined that the CxT values used in the monthly reports for the water treatment plants on the Hanford site were invalid and required the performance of a tracer study at each plant. In response to that determination, a tracer study will be performed to determine the actual contact times of the facilities for the CxT calculations

  3. Tumoral tracers

    International Nuclear Information System (INIS)

    Camargo, E.E.

    1979-01-01

    Direct tumor tracers are subdivided in the following categories:metabolite tracers, antitumoral tracers, radioactive proteins and cations. Use of 67 Ga-citrate as a clinically important tumoral tracer is emphasized and gallium-67 whole-body scintigraphy is discussed in detail. (M.A.) [pt

  4. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach.

    Science.gov (United States)

    Salamon, Johannes; Hofmann, Martin; Jung, Caroline; Kaul, Michael Gerhard; Werner, Franziska; Them, Kolja; Reimer, Rudolph; Nielsen, Peter; Vom Scheidt, Annika; Adam, Gerhard; Knopp, Tobias; Ittrich, Harald

    2016-01-01

    In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI) / magnetic resonance imaging (MRI) road map approach and an MPI-guided approach using a blood pool tracer. A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4) was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography. Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide. 4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.

  5. Magnetic Particle / Magnetic Resonance Imaging: In-Vitro MPI-Guided Real Time Catheter Tracking and 4D Angioplasty Using a Road Map and Blood Pool Tracer Approach.

    Directory of Open Access Journals (Sweden)

    Johannes Salamon

    Full Text Available In-vitro evaluation of the feasibility of 4D real time tracking of endovascular devices and stenosis treatment with a magnetic particle imaging (MPI / magnetic resonance imaging (MRI road map approach and an MPI-guided approach using a blood pool tracer.A guide wire and angioplasty-catheter were labeled with a thin layer of magnetic lacquer. For real time MPI a custom made software framework was developed. A stenotic vessel phantom filled with saline or superparamagnetic iron oxide nanoparticles (MM4 was equipped with bimodal fiducial markers for co-registration in preclinical 7T MRI and MPI. In-vitro angioplasty was performed inflating the balloon with saline or MM4. MPI data were acquired using a field of view of 37.3×37.3×18.6 mm3 and a frame rate of 46 volumes/sec. Analysis of the magnetic lacquer-marks on the devices were performed with electron microscopy, atomic absorption spectrometry and micro-computed tomography.Magnetic marks allowed for MPI/MRI guidance of interventional devices. Bimodal fiducial markers enable MPI/MRI image fusion for MRI based roadmapping. MRI roadmapping and the blood pool tracer approach facilitate MPI real time monitoring of in-vitro angioplasty. Successful angioplasty was verified with MPI and MRI. Magnetic marks consist of micrometer sized ferromagnetic plates mainly composed of iron and iron oxide.4D real time MP imaging, tracking and guiding of endovascular instruments and in-vitro angioplasty is feasible. In addition to an approach that requires a blood pool tracer, MRI based roadmapping might emerge as a promising tool for radiation free 4D MPI-guided interventions.

  6. Environmental Tracers

    Directory of Open Access Journals (Sweden)

    Trevor Elliot

    2014-10-01

    Full Text Available Environmental tracers continue to provide an important tool for understanding the source, flow and mixing dynamics of water resource systems through their imprint on the system or their sensitivity to alteration within it. However, 60 years or so after the first isotopic tracer studies were applied to hydrology, the use of isotopes and other environmental tracers are still not routinely necessarily applied in hydrogeological and water resources investigations where appropriate. There is therefore a continuing need to promote their use for developing sustainable management policies for the protection of water resources and the aquatic environment. This Special Issue focuses on the robustness or fitness-for-purpose of the application and use of environmental tracers in addressing problems and opportunities scientifically, to promote their wider use and to address substantive issues of vulnerability, sustainability, and uncertainty in (groundwater resources systems and their management.

  7. General circulation and tracers: studies in the Western Indian Ocean

    International Nuclear Information System (INIS)

    Jamous, Daniel

    1991-01-01

    The main question addressed in this thesis is how to best use the information obtained from hydro-biogeochemical tracer data, to study the oceanic general circulation in the Western Indian Ocean. First, a principal component analysis is performed on a historical data set. The tracers considered are temperature, salinity, density, oxygen, phosphate and silica. The method reduces the amount of data to be considered by a factor of 5. It reproduces correctly and efficiently the large-scale distributions of these oceanic properties. The analysed data are then used in a finite-difference nonlinear inverse model. The grid has a resolution of 4 deg. by 4 deg.. Dynamical as well as tracer conservation constraints are used. These constraints are well satisfied by the obtained solutions but the associated errors remain large. Additional constraints would be required in order to discuss the different solutions in more detail. Finally, a qualitative study is done on the deep distribution of helium-3. The data show several important features linked to hydrothermal input in the Gulf of Aden and on the Central Indian Ridge, and to the origin of water masses and deep circulation characteristics. However additional data are required in order to clarify the distribution of this tracer in other key areas. (author) [fr

  8. Chemical Tracer Methods: Chapter 7

    Science.gov (United States)

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  9. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  10. 18F-FDOPA PET/MRI fusion in patients with primary/recurrent gliomas: Initial experience

    International Nuclear Information System (INIS)

    Ledezma, Carlos J.; Chen, Wei; Sai, Victor; Freitas, Bonnie; Cloughesy, Tim; Czernin, Johannes; Pope, Whitney

    2009-01-01

    Background and purpose: 18 F-FDOPA PET demonstrates higher sensitivity and specificity for gliomas than traditional [ 18 F] FDG PET imaging. However, PET provides limited anatomic localization. The purpose of this study was to determine whether 18 F-FDOPA PET/MRI fusion can provide precise anatomic localization of abnormal tracer uptake and how this activity corresponds to MR signal abnormality. Methods: Two groups of patients were analyzed. Group I consisted of 21 patients who underwent 18 F-FDOPA PET and MRI followed by craniotomy for tumor resection. Group II consisted of 70 patients with a pathological diagnosis of glioma that had 18 F-FDOPA PET and MRI but lacked additional pathologic follow-up. Fused 18 F-FDOPA PET and MRI images were analyzed for concordance and correlated with histopathologic data. Results: Fusion technology facilitated precise anatomical localization of 18 F-FDOPA activity. In group I, all 21 cases showed pathology-confirmed tumor. Of these, 18 F-FDOPA scans were positive in 9/10 (90%) previously unresected tumors, and 11/11 (100%) of recurrent tumors. Of the 70 patients in group II, concordance between MRI and 18 F-FDOPA was found in 49/54 (90.1%) of patients with sufficient follow-up; in the remaining 16 patients concordance could not be determined due to lack of follow-up. 18 F-FDOPA labeling was comparable in both high- and low-grade gliomas and identified both enhancing and non-enhancing tumor equally well. In some cases, 18 F-FDOPA activity preceded tumor detection on MRI. Conclusion: 18 F-FDOPA PET/MRI fusion provides precise anatomic localization of tracer uptake and labels enhancing and non-enhancing tumor well. In a small minority of cases, 18 F-FDOPA activity may identify tumor not visible on MRI.

  11. High sensitivity tracer imaging of iron oxides using magnetic particle imaging

    International Nuclear Information System (INIS)

    Goodwill, Patrick; Konkle, Justin; Lu, Kuan; Zheng, Bo; Conolly, Steven

    2014-01-01

    Full text: Magnetic Particle Imaging (MPI) is a new tracer imaging modality that is gaining significant interest from NMR and MRI researchers. While the physics of MPI differ substantially from MRI, it employs hardware and imaging concepts that are familiar to MRI researchers, such as magnetic excitation and detection, pulse sequences, and relaxation effects. Furthermore, MPI employs the same superparamagnetic iron oxide (SPIO) contrast agents that are sometimes used for MR angiography and are often used for MRI cell tracking studies. These SPIOs are much safer for humans than iodine or gadolinium, especially for Chronic Kidney Disease (CKD) patients. The weak kidneys of CKD patients cannot safely excrete iodine or gadolinium, leading to increased morbidity and mortality after iodinated X-ray or CT angiograms, or after gadolinium-MRA studies. Iron oxides, on the other hand, are processed in the liver, and have been shown to be safe even for CKD patients. Unlike the 'black blood' contrast generated by SPIOs in MRI due to increased T2 dephasing, SPIOs in MPI generate positive, 'bright blood' contrast. With this ideal contrast, even prototype MPI scanners can already achieve fast, high-sensitivity, and high-contrast angiograms with millimeter-scale resolutions in phantoms and in animals. Moreover, MPI shows great potential for an exciting array of applications, including stem cell tracking in vivo, first-pass contrast studies to diagnose or stage cancer, and inflammation imaging in vivo. So far, only a handful of prototype small-animal MPI scanners have been constructed worldwide. Hence, MPI is open to great advances, especially in hardware, pulse sequence, and nanoparticle improvements, with the potential to revolutionize the biomedical imaging field. (author)

  12. High sensitivity tracer imaging of iron oxides using magnetic particle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goodwill, Patrick [University of California, Dept. of Bioengineering, Berkeley, CA (United States); Konkle, Justin; Lu, Kuan; Zheng, Bo [UC Berkeley (UCSF), Joint Graduate Group in Bioengineering, CA (United States); Conolly, Steven [University of California, Berkeley Bioengineering, Electrical Engineering, and Computer Science, CA (United States)

    2014-07-01

    Full text: Magnetic Particle Imaging (MPI) is a new tracer imaging modality that is gaining significant interest from NMR and MRI researchers. While the physics of MPI differ substantially from MRI, it employs hardware and imaging concepts that are familiar to MRI researchers, such as magnetic excitation and detection, pulse sequences, and relaxation effects. Furthermore, MPI employs the same superparamagnetic iron oxide (SPIO) contrast agents that are sometimes used for MR angiography and are often used for MRI cell tracking studies. These SPIOs are much safer for humans than iodine or gadolinium, especially for Chronic Kidney Disease (CKD) patients. The weak kidneys of CKD patients cannot safely excrete iodine or gadolinium, leading to increased morbidity and mortality after iodinated X-ray or CT angiograms, or after gadolinium-MRA studies. Iron oxides, on the other hand, are processed in the liver, and have been shown to be safe even for CKD patients. Unlike the 'black blood' contrast generated by SPIOs in MRI due to increased T2 dephasing, SPIOs in MPI generate positive, 'bright blood' contrast. With this ideal contrast, even prototype MPI scanners can already achieve fast, high-sensitivity, and high-contrast angiograms with millimeter-scale resolutions in phantoms and in animals. Moreover, MPI shows great potential for an exciting array of applications, including stem cell tracking in vivo, first-pass contrast studies to diagnose or stage cancer, and inflammation imaging in vivo. So far, only a handful of prototype small-animal MPI scanners have been constructed worldwide. Hence, MPI is open to great advances, especially in hardware, pulse sequence, and nanoparticle improvements, with the potential to revolutionize the biomedical imaging field. (author)

  13. Concentration dynamics in lakes and reservoirs. Studies using radioactive tracers

    International Nuclear Information System (INIS)

    Gilath, Ch.

    1983-01-01

    The use of radioactive tracers for the investigation of concentration dynamics of inert soluble matter in lakes and reservoirs is reviewed. Shallow and deep stratified lakes are considered. The mechanism of mixing in lakes, flow pattern and input - output response are discussed. The methodology of the use of radioactive tracers for concentration dynamic studies is described. Examples of various investigations are reviewed. The dynamics of shallow lakes can be found and expressed in terms of transfer functions, axial dispersion models, residence time distributions and sometimes only semiquantitative information about the flow pattern. The dynamics of deep, stratified lakes is more complex and difficult to investigate with tracers. Flow pattern, horizontal and vertical eddy diffusivities, mass transfer between the hypolimnion and epilimnion are tools used for describing this dynamics. (author)

  14. Studying neuroanatomy using MRI.

    Science.gov (United States)

    Lerch, Jason P; van der Kouwe, André J W; Raznahan, Armin; Paus, Tomáš; Johansen-Berg, Heidi; Miller, Karla L; Smith, Stephen M; Fischl, Bruce; Sotiropoulos, Stamatios N

    2017-02-23

    The study of neuroanatomy using imaging enables key insights into how our brains function, are shaped by genes and environment, and change with development, aging and disease. Developments in MRI acquisition, image processing and data modeling have been key to these advances. However, MRI provides an indirect measurement of the biological signals we aim to investigate. Thus, artifacts and key questions of correct interpretation can confound the readouts provided by anatomical MRI. In this review we provide an overview of the methods for measuring macro- and mesoscopic structure and for inferring microstructural properties; we also describe key artifacts and confounds that can lead to incorrect conclusions. Ultimately, we believe that, although methods need to improve and caution is required in interpretation, structural MRI continues to have great promise in furthering our understanding of how the brain works.

  15. Methods for conduct of atmospheric tracer studies at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G H; Stone, D J.M.; Pascoe, J H [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). Environment Division

    2000-07-01

    A perfluorocarbon atmospheric tracer system has been developed to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. This report discusses the tracer release, sampling and analysis methods.

  16. A study plan for determining recharge rates at the Hanford Site using environmental tracers

    International Nuclear Information System (INIS)

    Murphy, E.M.; Szercsody, J.E.; Phillips, S.J.

    1991-02-01

    This report presents a study plan for estimating recharge at the Hanford Site using environmental tracers. Past operations at the Hanford Site have led to both soil and groundwater contamination, and recharge is one of the primary mechanisms for transporting contaminants through the vadose zone and into the groundwater. An alternative to using fixed lysimeters for determining recharge rates in the vadose zone is to use environmental tracers. Tracers that have been used to study water movement in the vadose zone include total chloride, 36 Cl, 3 H, and 2 H/ 18 O. Atmospheric levels of 36 Cl and 3 H increased during nuclear bomb testing in the Pacific, and the resulting ''bomb pulse'' or peak concentration can be measured in the soil profile. Locally, past operations at the Hanford Site have resulted in the atmospheric release of numerous chemical and isotopic tracers, including nitrate, 129 I, and 99 Tc. Seven study sites on the Hanford Site have been selected, in two primary soil types that are believed to represent the extremes in recharge, the Quincy sand and the Warden silt loam. An additional background study site upwind of the Hanford facilities has been chosen at the Yakima Firing Center. Six tracer techniques (total chloride, 36 Cl, 3 H, nitrate, 129 I, and 99 Tc) will be tested on at least one site in the Quincy sand, one site in the Warden silt loam, and the background site, to determine which combination of tracers works best for a given soil type. In subsequent years, additional sites will be investigated. The use of environmental tracers is perhaps the only cost-effective method for estimating the spatial variability of recharge at a site as large as Hanford. The tracer techniques used at Hanford have wide applicability at other arid sites. 166 refs., 41 figs., 16 tabs

  17. Tracer-tracer relations as a tool for research on polar ozone loss

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rolf

    2010-07-01

    The report includes the following chapters: (1) Introduction: ozone in the atmosphere, anthropogenic influence on the ozone layer, polar stratospheric ozone loss; (2) Tracer-tracer relations in the stratosphere: tracer-tracer relations as a tool in atmospheric research; impact of cosmic-ray-induced heterogeneous chemistry on polar ozone; (3) quantifying polar ozone loss from ozone-tracer relations: principles of tracer-tracer correlation techniques; reference ozone-tracer relations in the early polar vortex; impact of mixing on ozone-tracer relations in the polar vortex; impact of mesospheric intrusions on ozone-tracer relations in the stratospheric polar vortex calculation of chemical ozone loss in the arctic in March 2003 based on ILAS-II measurements; (4) epilogue.

  18. When tractography meets tracer injections: a systematic study of trends and variation sources of diffusion-based connectivity.

    Science.gov (United States)

    Aydogan, Dogu Baran; Jacobs, Russell; Dulawa, Stephanie; Thompson, Summer L; Francois, Maite Christi; Toga, Arthur W; Dong, Hongwei; Knowles, James A; Shi, Yonggang

    2018-04-16

    Tractography is a powerful technique capable of non-invasively reconstructing the structural connections in the brain using diffusion MRI images, but the validation of tractograms is challenging due to lack of ground truth. Owing to recent developments in mapping the mouse brain connectome, high-resolution tracer injection-based axonal projection maps have been created and quickly adopted for the validation of tractography. Previous studies using tracer injections mainly focused on investigating the match in projections and optimal tractography protocols. Being a complicated technique, however, tractography relies on multiple stages of operations and parameters. These factors introduce large variabilities in tractograms, hindering the optimization of protocols and making the interpretation of results difficult. Based on this observation, in contrast to previous studies, in this work we focused on quantifying and ranking the amount of performance variation introduced by these factors. For this purpose, we performed over a million tractography experiments and studied the variability across different subjects, injections, anatomical constraints and tractography parameters. By using N-way ANOVA analysis, we show that all tractography parameters are significant and importantly performance variations with respect to the differences in subjects are comparable to the variations due to tractography parameters, which strongly underlines the importance of fully documenting the tractography protocols in scientific experiments. We also quantitatively show that inclusion of anatomical constraints is the most significant factor for improving tractography performance. Although this critical factor helps reduce false positives, our analysis indicates that anatomy-informed tractography still fails to capture a large portion of axonal projections.

  19. Data volume of atmospheric tracer studies at Lucas Heights, NSW, Australia -1996-1997

    International Nuclear Information System (INIS)

    Clark, G.H.; Stone, D.J.M.; Pascoe, J.H.

    2000-01-01

    A perfluorocarbon atmospheric tracer system has been used to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. Tracers have been released from two locations: a laboratory vent near the ridge of the Woronora river valley and from the HIFAR research reactor ventilation system. Most studies have been conducted during the early to late morning periods when valley influences might be expected on dispersion of the tracer plume. This report summarises the meteorological and tracer air concentration data and makes comparisons with estimates from a simple gaussian dispersion model. It is intended that the data will also be used for evaluation of more elaborate wind field and atmospheric models

  20. Aluminum metabolism studied by [sup 26]Al tracer using AMS technique

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Koichi (Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology); Yumoto, Sakae; Nagai, Hisao; Hosoyama, Yoshiyuki; Imamura, Mineo; Hotta, Masayoshi; Ohashi, Hideo

    1992-01-01

    By accelerator mass spectrometry (AMS), we studied aluminum metabolism using [sup 26]Al as a tracer. To investigate the role of aluminum toxicity in the etiology of amyotrophic lateral sclerosis (ALS) and Alzheimer's disease, aluminum incorporation into the rat cerebrum was studied. When healthy rats were injected intraperitoneally with [sup 26]Al, a considerable amount of the tracer was incorporated into the brain within only 5 days after the injection. This [sup 26]Al accumulation was apparently irreversible, since it persisted even after 75 days. (author).

  1. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to provide the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.

  2. Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracers

    Energy Technology Data Exchange (ETDEWEB)

    Burgos, Ninon [University College London, Translational Imaging Group, Centre for Medical Image Computing, London (United Kingdom); Cardoso, M.J.; Modat, Marc; Ourselin, Sebastien [University College London, Translational Imaging Group, Centre for Medical Image Computing, London (United Kingdom); University College London, Dementia Research Centre, Institute of Neurology, London (United Kingdom); Thielemans, Kris; Dickson, John [University College London, Institute of Nuclear Medicine, London (United Kingdom); Schott, Jonathan M. [University College London, Dementia Research Centre, Institute of Neurology, London (United Kingdom); Atkinson, David [University College London, Centre for Medical Imaging, London (United Kingdom); Arridge, Simon R. [University College London, Centre for Medical Image Computing, London (United Kingdom); Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2015-08-15

    Positron Emission Tomography/Magnetic Resonance Imaging (PET/MR) scanners are expected to offer a new range of clinical applications. Attenuation correction is an essential requirement for quantification of PET data but MRI images do not directly provide a patient-specific attenuation map. Methods We further validate and extend a Computed Tomography (CT) and attenuation map (μ-map) synthesis method based on pre-acquired MRI-CT image pairs. The validation consists of comparing the CT images synthesised with the proposed method to the original CT images. PET images were acquired using two different tracers ({sup 18}F-FDG and {sup 18}F-florbetapir). They were then reconstructed and corrected for attenuation using the synthetic μ-maps and compared to the reference PET images corrected with the CT-based μ-maps. During the validation, we observed that the CT synthesis was inaccurate in areas such as the neck and the cerebellum, and propose a refinement to mitigate these problems, as well as an extension of the method to multi-contrast MRI data. Results With the improvements proposed, a significant enhancement in CT synthesis, which results in a reduced absolute error and a decrease in the bias when reconstructing PET images, was observed. For both tracers, on average, the absolute difference between the reference PET images and the PET images corrected with the proposed method was less than 2%, with a bias inferior to 1%. Conclusion With the proposed method, attenuation information can be accurately derived from MRI images by synthesising CT using routine anatomical sequences. MRI sequences, or combination of sequences, can be used to synthesise CT images, as long as they provide sufficient anatomical information. (orig.)

  3. Quadratic tracer dynamical models tobacco growth

    International Nuclear Information System (INIS)

    Qiang Jiyi; Hua Cuncai; Wang Shaohua

    2011-01-01

    In order to study the non-uniformly transferring process of some tracer dosages, we assume that the absorption of some tracer by tobacco is a quadratic function of the tracer quantity of the tracer in the case of fast absorption, whereas the exclusion of the tracer from tobacco is a linear function of the tracer quantity in the case of slow exclusion, after the tracer is introduced into tobacco once at zero time. A single-compartment quadratic dynamical model of Logistic type is established for the leaves of tobacco. Then, a two-compartment quadratic dynamical model is established for leaves and calms of the tobacco. Qualitative analysis of the models shows that the tracer applied to the leaves of the tobacco is excluded finally; however, the tracer stays at the tobacco for finite time. Two methods are also given for computing the parameters in the models. Finally, the results of the models are verified by the 32 P experiment for the absorption of tobacco. (authors)

  4. Studies on groundwater transport in fractured crystalline rock under controlled conditions using nonradioactive tracers

    International Nuclear Information System (INIS)

    Gustafsson, E.; Klockars, C.-E.

    1981-04-01

    The purpose of the investigation has been study the following parameters along existing fractures between two boreholes: hydraulic properties of rock mass and fractures; adsorptive properties of some selected tracers during transport along fractures; dispersivity and dilution of tracers during transport in fractures; kinematic porosity of fractured bedrock. The procedure has been to determine the hydraulic properties of a rock mass by means of conventional hydraulic testing methods in 100 m deep boreholes, and to study transport mechanisms and properties of selected tracers in a selected fracture zone between two boreholes. (Auth.)

  5. Tracer research in process engineering

    International Nuclear Information System (INIS)

    Iller, E.

    1992-01-01

    The book is a review of modern applications of tracer techniques in chemical and process engineering studies. The next topics have been extensively presented: 1) media flow through apparatus; 2) the tracers in the study of media flow dynamics through apparatus; 3) mathematical interpretation of experimental data from impulse-response method; 4) the models of media flow through chemical reactors and apparatus; 5) radiotracers in mass transport study; 6) examples of practical applications of tracer methods in industrial objects. 84 refs, 96 figs, 31 tabs

  6. IClinfMRI Software for Integrating Functional MRI Techniques in Presurgical Mapping and Clinical Studies.

    Science.gov (United States)

    Hsu, Ai-Ling; Hou, Ping; Johnson, Jason M; Wu, Changwei W; Noll, Kyle R; Prabhu, Sujit S; Ferguson, Sherise D; Kumar, Vinodh A; Schomer, Donald F; Hazle, John D; Chen, Jyh-Horng; Liu, Ho-Ling

    2018-01-01

    Task-evoked and resting-state (rs) functional magnetic resonance imaging (fMRI) techniques have been applied to the clinical management of neurological diseases, exemplified by presurgical localization of eloquent cortex, to assist neurosurgeons in maximizing resection while preserving brain functions. In addition, recent studies have recommended incorporating cerebrovascular reactivity (CVR) imaging into clinical fMRI to evaluate the risk of lesion-induced neurovascular uncoupling (NVU). Although each of these imaging techniques possesses its own advantage for presurgical mapping, a specialized clinical software that integrates the three complementary techniques and promptly outputs the analyzed results to radiology and surgical navigation systems in a clinical format is still lacking. We developed the Integrated fMRI for Clinical Research (IClinfMRI) software to facilitate these needs. Beyond the independent processing of task-fMRI, rs-fMRI, and CVR mapping, IClinfMRI encompasses three unique functions: (1) supporting the interactive rs-fMRI mapping while visualizing task-fMRI results (or results from published meta-analysis) as a guidance map, (2) indicating/visualizing the NVU potential on analyzed fMRI maps, and (3) exporting these advanced mapping results in a Digital Imaging and Communications in Medicine (DICOM) format that are ready to export to a picture archiving and communication system (PACS) and a surgical navigation system. In summary, IClinfMRI has the merits of efficiently translating and integrating state-of-the-art imaging techniques for presurgical functional mapping and clinical fMRI studies.

  7. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    International Nuclear Information System (INIS)

    2004-01-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland

  8. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland.

  9. Plan for radionuclide tracer studies of the residence time distribution in the Wilsonville dissolver and preheater

    International Nuclear Information System (INIS)

    Jolley, R.L.; Begovich, J.M.; Brashear, H.R.

    1983-12-01

    Stimulus-response measurements using radiotracers to measure residence time distribution (RTD) and hydrodynamic parameters for the preheaters and dissolvers at the Ft. Lewis Solvent Refined Coal (SRC) and the Exxon Donor Solvent (EDS) coal conversion pilot plants are reviewed. A plan is also presented for a series of radioactive tracer studies proposed for the Advanced Coal Liquefaction Facility at Wilsonville, Alabama, to measure the RTD for the preheater and dissolvers in the SRC-I mode. The tracer for the gas phase will be 133 Xe, and 198 Au (on carbonized resin or as an aqueous colloidal suspension) will be used as the slurry tracer. Four experimental phases are recommended for the RTD tracer studies: (1) preheater; (2) dissolver with 100% takeoff; (3) dissolver with 100% takeoff and solids withdrawal; and (4) dissolver with 50% takeoff. Eighteen gas-tracer and 22 liquid-tracer injections are projected to accomplish the four experimental phases. Two to four tracer injections are projected for preliminary tests to ensure the capability of safe injection of the radiotracers and the collection of statistically significant data. A complete projected cost and time schedule is provided, including procurement of necessary components, preparation of the radiotracers, assembly and testing of tracer injection apparatus and detection systems, onsite work and tracer injections, laboratory experimentation, data analysis, and report writing

  10. Tracer dating and ocean ventilation

    International Nuclear Information System (INIS)

    Thiele, G.; Sarmiento, J.L.

    1990-01-01

    The interpretation of transient tracer observations depends on difficult to obtain information on the evolution in time of the tracer boundary conditions and interior distributions. Recent studies have attempted to circumvent this problem by making use of a derived quantity, age, based on the simultaneous distribution of two complementary tracers, such as tritium and its daughter, helium 3. The age is defined with reference to the surface such that the boundary condition takes on a constant value of zero. The authors use a two-dimensional model to explore the circumstances under which such a combination of conservation equations for two complementary tracers can lead to a cancellation of the time derivative terms. An interesting aspect of this approach is that mixing can serve as a source or sink of tracer based age. The authors define an idealized ventilation age tracer that is conservative with respect to mixing, and they explore how its behavior compares with that of the tracer-based ages over a range of advective and diffusive parameters

  11. Radioactive tracers in the sea

    International Nuclear Information System (INIS)

    Jenkins, W.J.; Livingston, H.D.

    1980-01-01

    Artificial radionuclides introduced to the oceans during the last four decades have proved invaluable tools for study of many processes in marine water columns and sediments. Both global and close-in fallout of radioactivity from atmospheric nuclear weapons testing have distributed these radionuclides widely, and in amounts sufficient to be useful as tracers. An additional source of considerable significance and tracer potential comes from coastal discharges of European nuclear fuel reprocessing wastes. The nature of these sources, types and amounts of radionuclides introduced and the time histories of their introduction generate a variety of tracer distributions which illuminate a broad spectrum of physical and chemical processes active over a wide range of timescales. Depending on their respective chemistries, artificial radionuclides have been demonstrated to exhibit both conservative and non-conservative properties in the oceans. Some examples are given of the uses made of soluble, conservative tracers for the study of oceanic transport processes and of non-conservative tracers for studies of processes which move them to, and mix them within, marine sediments. Sampling and measurement techniques which have been used in these studies are described

  12. Development of radioisotope tracer technology

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee; Park, Soon Chul; Lim, Dong Soon; Kim, Jae Ho; Lee, Jae Choon; Lee, Doo Sung; Cho, Yong Suk; Shin, Sung Kuan

    2000-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss and the amount of wear was established. The equipment was developed to adjust the energy of proton which collides with the surface of tappet. The tracer project team has participated into the tracer test for estimating the efficiency of RFCC system in SK cooperation. From the experiment the tracer team has obtained the primary elements to be considered for judging the efficiency of RFCC unit. By developing the tracer techniques to test huge industrial units like RFCC, the tracer team will be able to support the local industries that require technical services to solve any urgent trouble. (author)

  13. Hanford 100-N Area Tracer Study Final Report

    International Nuclear Information System (INIS)

    Kretzschmar, S.P.; Bedi, G.S.; Martinez, P.; Ervin, K.

    1996-09-01

    This document provides an engineering tracer study final report for the determination of contact time for the disinfection process at Group A Nontransient Noncommunity water treatment plant for the 100- N Water Plant (located on the Hanford Site in Richland, Washington). The purpose of this study is to determine the actual detention time within the plant clearwell, and the disinfection contact time at several clearwell effluent flow rates

  14. Multimodal 18F-Fluciclovine PET/MRI and Ultrasound-Guided Neurosurgery of an Anaplastic Oligodendroglioma.

    Science.gov (United States)

    Karlberg, Anna; Berntsen, Erik Magnus; Johansen, Håkon; Myrthue, Mariane; Skjulsvik, Anne Jarstein; Reinertsen, Ingerid; Esmaeili, Morteza; Dai, Hong Yan; Xiao, Yiming; Rivaz, Hassan; Borghammer, Per; Solheim, Ole; Eikenes, Live

    2017-12-01

    Structural magnetic resonance imaging (MRI) and histopathologic tissue sampling are routinely performed as part of the diagnostic workup for patients with glioma. Because of the heterogeneous nature of gliomas, there is a risk of undergrading caused by histopathologic sampling errors. MRI has limitations in identifying tumor grade and type, detecting diffuse invasive growth, and separating recurrences from treatment induced changes. Positron emission tomography (PET) can provide quantitative information of cellular activity and metabolism, and may therefore complement MRI. In this report, we present the first patient with brain glioma examined with simultaneous PET/MRI using the amino acid tracer 18 F-fluciclovine ( 18 F-FACBC) for intraoperative image-guided surgery. A previously healthy 60-year old woman was admitted to the emergency care with speech difficulties and a mild left-sided hemiparesis. MRI revealed a tumor that was suggestive of glioma. Before surgery, the patient underwent a simultaneous PET/MRI examination. Fused PET/MRI, T1, FLAIR, and intraoperative three-dimensional ultrasound images were used to guide histopathologic tissue sampling and surgical resection. Navigated, image-guided histopathologic samples were compared with PET/MRI image data to assess the additional value of the PET acquisition. Histopathologic analysis showed anaplastic oligodendroglioma in the most malignant parts of the tumor, while several regions were World Health Organization (WHO) grade II. 18 F-Fluciclovine uptake was found in parts of the tumor where regional WHO grade, cell proliferation, and cell densities were highest. This finding suggests that PET/MRI with this tracer could be used to improve accuracy in histopathologic tissue sampling and grading, and possibly for guiding treatments targeting the most malignant part of extensive and eloquent gliomas. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  15. Molecular MRI based on hyper-polarized xenon

    International Nuclear Information System (INIS)

    Tassali, Nawal

    2012-01-01

    Magnetic Resonance Imaging (MRI) has a high importance in medicine as it enables the observation of the organs inside the body without the use of radiative or invasive techniques. However it is known to suffer from poor sensitivity. To circumvent this limitation, a key solution resides in the use of hyper-polarized species. Among the entities with which we can drastically increase nuclear polarization, xenon has very specific properties through its interactions with its close environment that lead to a wide chemical shift bandwidth. The goal is thus to use it as a tracer. This PhD thesis focuses on the concept of 129 Xe MRI-based sensors for the detection of biological events. In this approach, hyper-polarized xenon is vectorized to biological targets via functionalized host systems, and then localized thanks to fast dedicated MRI sequences. The conception and set-up of a spin-exchange optical pumping device is first described. Then studies about the interaction of the hyper-polarized noble gas with new cryptophanes susceptible to constitute powerful host molecules are detailed. Also the implementation of recent MRI sequences optimized for the transient character of the hyper-polarization and taking profit of the xenon in-out exchange is described. Applications of this approach for the detection of metallic ions and cellular receptors are studied. Finally, our first in vivo results on a small animal model are presented. (author) [fr

  16. Stable nuclide tracer studies and human amino acid requirements. A summary

    International Nuclear Information System (INIS)

    Young, V.R.

    1994-01-01

    The nutritional requirements for proteins have been estimated for various age groups. The current status of knowledge concerning the quantitative needs for specific indispensable amino acids was reviewed and it was concluded that, except for infants, current values for pre-school children, school age children and healthy adults are based on limited experimental data and/or on results from nitrogen balance determinations which are open to serious question regarding their nutritional significance. A review of 13 C-labelled tracer studies carried out in MIT laboratories was undertaken to demonstrate the applicability of stable nuclide tracer studies for purposes of determining the amino acid requirements of humans. 5 refs

  17. Studies of Tracer Dispersion and Fluid Flow in Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Rage, T.

    1996-12-31

    This doctoral thesis explores the connection between the topology of a porous medium and its macroscopic transport properties and is based on computerized simulation. In porous media, both diffusion and convection contribute to the dispersion of a tracer and their combined effect is emphasized. The governing equations are solved numerically, using finite differences and Monte Carlo technique. The influence of finite Reynolds number on the outcome of echo-experiments is discussed. Comparing experiments and simulations it is found that nonlinear inertial forces lead to a visible deformation of a returned tracer at surprisingly small Reynolds numbers. In a study of tracer dispersion and fluid flow in periodic arrays of discs it is demonstrated that the mechanisms of mechanical dispersion in periodic media and in natural (non-periodic) porous media are essentially different. Measurements of the percolation probability distribution of a sandstone sample is presented. Local porosity theory predicts that this simple geometric function of a porous medium is of dominant importance for its macroscopic transport properties. It is demonstrated that many aspects of transport through fractures can be studied by using simple but realistic models and readily available computer resources. An example may be the transport of hydrocarbon fluids from the source rock to a reservoir. 165 refs., 44 figs., 1 table

  18. Tracer studies of flotation in the laboratory and in mineral processing plant

    International Nuclear Information System (INIS)

    Niemi, A.J.; Thereska, J.; Plasari, E.; Kacaj, M.

    1993-01-01

    Radioisotope tracers have a proven application for the extraction of residence time distributions and the evaluation of flotation rates in industry. This paper shows how values of the rate factor k are scaled up on the basis of flotation in the laboratory and tracer tests in plant. The procedure is illustrated by a theoretical study and by experimental data. The information obtained can be introduced into models of larger flotation systems. (author)

  19. Regional distribution and kinetics of [18F]fluciclovine (anti-[18F]FACBC), a tracer of amino acid transport, in subjects with primary prostate cancer.

    Science.gov (United States)

    Sörensen, Jens; Owenius, Rikard; Lax, Michelle; Johansson, Silvia

    2013-02-01

    [(18)F]Fluciclovine (anti-[(18)F]FACBC) is a synthetic amino acid developed for PET assessment of the anabolic component of tumour metabolism in clinical routine. This phase 1 trial evaluated the safety, tracer stability and uptake kinetics of [(18)F]fluciclovine in patients. Six patients with biopsy-proven prostate cancer were investigated with 3-T MRI and PET/CT. All underwent dynamic [(18)F]fluciclovine PET/CT of the pelvic area for up to 120 min after injection of 418 ± 10 MBq of tracer with simultaneous blood sampling of radioactivity. The kinetics of uptake in tumours and normal tissues were evaluated using standardized uptake values (SUVs) and compartmental modelling. Tumour deposits as defined by MRI were clearly visualized by PET. Urine excretion was minimal and normal tissue background was low. Uptake of [(18)F]fluciclovine in tumour from the blood was rapid and the tumour-to-normal tissue contrast was highest between 1 and 15 min after injection with a 65 % reduction in mean tumour uptake at 90 min after injection. A one-compartment model fitted the tracer kinetics well. Early SUVs correlated well with both the influx rate constant (K (1)) and the volume of distribution of the tracer (V (T)). There were no signs of tracer metabolite formation. The product was well tolerated in all patients without significant adverse events. [(18)F]Fluciclovine shows high uptake in prostate cancer deposits and appears safe for use in humans. The production is robust and the formulation stable in vivo. An early imaging window seems to provide the best visual results. SUV measurements capture most of the kinetic information that can be obtained from more advanced models, potentially simplifying quantification in future studies.

  20. Isotopic marking and tracers

    International Nuclear Information System (INIS)

    Morel, F.

    1997-01-01

    The use of radioactive isotopes as tracers in biology has been developed thanks to the economic generation of the required isotopes in accelerators and nuclear reactors, and to the multiple applications of tracers in the life domain; the most usual isotopes employed in biology are carbon, hydrogen, phosphorus and sulfur isotopes, because these elements are present in most of organic molecules. Most of the life science knowledge appears to be dependent to the extensive use of nuclear tools and radioactive tracers; the example of the utilization of radioactive phosphorus marked ATP to study the multiple reactions with proteins, nucleic acids, etc., is given

  1. Measurement of open streams by using tracers

    International Nuclear Information System (INIS)

    Ramos, German F.; Tarquino, W.; Curcuy, H.; Orozco, C.

    1999-01-01

    This paper presents an intercomparison study to be carried out between flux measurements by using tracers and moulinet. This intercomparison is scheduled to be performed at the measurement station belonging to the National Service of Meteorology and Hydrology (SENAMHI). Two techniques of tracer dilution are outstanded: total evaluation with tracer punctual injection and punctual evaluation with tracer continuous injection. Total evaluation with tracer punctual injection has been used since this technique is considered to be more suitable for hydrology purposes

  2. Predictive value of tracer studies for 131I treatment in hyperthyroid cats

    International Nuclear Information System (INIS)

    Broome, M.R.; Turrel, J.M.; Hays, M.T.

    1988-01-01

    In 76 cats with hyperthyroidism, peak thyroidal radioiodine ( 131 I) uptakes and effective half-lives were determined after administration of tracer and therapeutic activities of 131 I. In 6 additional hyperthyroid cats, only peak thyroidal uptakes after administration of tracer and therapeutic activities of 131 I were determined. Good correlation was found between peak thyroidal uptakes of tracer and therapeutic 131 I; however, only fair correlation was observed between effective half-lives. In 79% of the cats, the effective half-life for therapeutic 131 I was longer than that for tracer 131 I. After administration of therapeutic activity of 131 I, monoexponential and biphasic decay curves were observed in 51 and 16 cats, respectively. Using therapeutic kinetic data, radiation doses to the thyroid gland were calculated retrospectively on the basis of 2 methods for determining the activity of 131 I administered: (1) actual administration of tracer-compensated activity and (2) hypothetic administration of uniform activity (3 mCi). Because of the good predictive ability of tracer kinetic data for the therapeutic kinetic data, the tracer-compensated radiation doses came significantly (P = 0.008) closer to the therapeutic goal than did the uniform-activity doses. In addition, the use of tracer kinetic information reduced the extent of the tendency for consistently high uniform-activity doses. A manual method for acquiring tracer kinetic data was developed and was an acceptable alternative to computerized techniques. Adoption of this method gives individuals and institutions with limited finances the opportunity to characterize the iodine kinetics in cats before proceeding with administration of therapeutic activities of 131 I

  3. Evaluation of B1 inhomogeneity effect on DCE-MRI data analysis of brain tumor patients at 3T.

    Science.gov (United States)

    Sengupta, Anirban; Gupta, Rakesh Kumar; Singh, Anup

    2017-12-02

    Dynamic-contrast-enhanced (DCE) MRI data acquired using gradient echo based sequences is affected by errors in flip angle (FA) due to transmit B 1 inhomogeneity (B 1 inh). The purpose of the study was to evaluate the effect of B 1 inh on quantitative analysis of DCE-MRI data of human brain tumor patients and to evaluate the clinical significance of B 1 inh correction of perfusion parameters (PPs) on tumor grading. An MRI study was conducted on 35 glioma patients at 3T. The patients had histologically confirmed glioma with 23 high-grade (HG) and 12 low-grade (LG). Data for B 1 -mapping, T 1 -mapping and DCE-MRI were acquired. Relative B 1 maps (B 1rel ) were generated using the saturated-double-angle method. T 1 -maps were computed using the variable flip-angle method. Post-processing was performed for conversion of signal-intensity time (S(t)) curve to concentration-time (C(t)) curve followed by tracer kinetic analysis (K trans , Ve, Vp, Kep) and first pass analysis (CBV, CBF) using the general tracer-kinetic model. DCE-MRI data was analyzed without and with B 1 inh correction and errors in PPs were computed. Receiver-operating-characteristic (ROC) analysis was performed on HG and LG patients. Simulations were carried out to understand the effect of B 1 inhomogeneity on DCE-MRI data analysis in a systematic way. S(t) curves mimicking those in tumor tissue, were generated and FA errors were introduced followed by error analysis of PPs. Dependence of FA-based errors on the concentration of contrast agent and on the duration of DCE-MRI data was also studied. Simulations were also done to obtain K trans of glioma patients at different B 1rel values and see whether grading is affected or not. Current study shows that B 1rel value higher than nominal results in an overestimation of C(t) curves as well as derived PPs and vice versa. Moreover, at same B 1rel values, errors were large for larger values of C(t). Simulation results showed that grade of patients can change

  4. Radioisotope tracer study in an aniline production reactor

    International Nuclear Information System (INIS)

    Pant, H.J.; Yelgoankar, V.N.; Mendhekar, G.N.

    1995-01-01

    A radioisotope tracer study was carried out in an aniline production reactor to investigate the cause of poor heat transfer from tube side to shell side in an aniline production (ANPO) reactor. The results of the study indicated that more than 50% of the shell volume was reduced due to deposition of the process material (i.e. fouling) on the shell walls and may be the cause of poor heat transfer in the reactor. (author). 2 refs., 2 figs

  5. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    Science.gov (United States)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against

  6. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain Site characterization study

    International Nuclear Information System (INIS)

    Dombrowski, T.; Stetzenbach, K.

    1993-01-01

    This report is in two parts one for the fluorinated benzoic acids and one for the fluorinated aliphatic acids. The assumptions made in the report regarding the amount of tracer that will be used, dilution of the tracer during the test and the length of exposure (if any) to individuals drinking the water were made by the authors. These assumptions must really come from the USGS hydrologists in charge of the c-well tracer testing program. Accurate estimates of dilution of the tracer during the test are also important because of solubility limitations of some of the tracers. Three of the difluorobenzoic acids have relatively low solubilities and may not be usable if the dilution estimates are large. The toxicologist that reviewed the document agreed with our conclusion that the fluorinated benzoic and toluic acids do not represent a health hazard if used under the conditions as outlined in the report. We are currently testing 15 of these compounds, and if even if three difluorobenzoic acids cannot be used because of solubility limitations we will still have 12 tracers. The toxicologist felt that the aliphatic fluorinated acids potentially present more of a health risk than the aromatic. This assessment was based on the fact of a known allergic response to halothane anesthetic. This risk, although minimal, is known and he felt that was enough reason to recommend against their use. The authors feel that the toxicologists interpretation of this risk was overly conservative, however, we will not go against his recommendation at this time for the following reasons. First, without the aliphatic compounds we still have 12 to 15 fluorinated aromatic acids which, should be enough for the c-well tests. Second, to get a permit to use aliphatic compounds would undoubtedly require a hearing which could be quite lengthy

  7. Potential study of bed filtration characteristics in impressed boreholes by radon tracer technique

    International Nuclear Information System (INIS)

    Litvinov, A.A.; Pinkenzon, D.B.; Makarov, M.S.; Vinarskij, M.S.

    1977-01-01

    Potential study of bed filtration characteristics in impressed boreholes by radon tracer method is shown. Effects recorded by radon tracer result from gamma radiation of short-living radon decay daughter products. During filtration of tracer through punched holes, cement stone, and rocks the products are deposited and cause a local effect for 2-3 hours. There is a shortage of short-living products in filtrated radon liquid and for some time (which is necessary for production of notable quantity of new decay products) it is practically not a gamma emitter. It is shown that the feature of effect formation governs the technique for well logging as well as interpretation of the results obtained

  8. Aligning Higher Education to Workforce Needs in Liberia: A Tracer Study of University Graduates in Liberia

    Science.gov (United States)

    Flomo, John S., Jr.

    2013-01-01

    This study investigated the congruence between higher education and the labor market from the perspectives of college graduates in Liberia. It specifically examined the alignment of the skills college students acquire in college to Liberia's labor market. The study employed a Tracer Study quantitative research methodology. Tracer study as a…

  9. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  10. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  11. Meteorological tracers in regional planning

    International Nuclear Information System (INIS)

    Mueller, K.H.

    1974-11-01

    Atmospheric tracers can be used as indicators to study both the ventilation of an urban region and its dispersion meteorology for air pollutants. A correlation analysis applied to the space-time dependent tracer concentrations is able to give transfer functions, the structure and characteristic parameters of which describe the meteorological and topographical situation of the urban region and its surroundings in an integral manner. To reduce the number of persons usually involved in a tracer experiment an automatic air sampling system had to be developed

  12. Laboratory studies into the use of the scandium-46-EDTA complex as a tracer for groundwater flow

    International Nuclear Information System (INIS)

    Cheng, H.; Nixon, S.C.

    1988-01-01

    Gamma ray emitting metal radionuclides, when complexed with an appropriate complexing agent, provide a wide choice of water tracers particularly for groundwater studies where a radionuclide of appropriate half-life suited to the particular study can be selected. Scandium-46 has easily detectable gamma emission and a suitable half-life (84 days) for medium term studies. It has been widely and successfully used as a tracer in studies of sediment movement but has not yet been introduced as a groundwater tracer. In our experiments the chemical aspects of the preparation of Sc-46-EDTA were studied in some detail and its behaviour in various mineralogical environments was evaluated with reference to the standard tracer, tritiated water. The experimental results have shown that the scandium cation can be easily complexed with EDTA to form soluble SC-EDTA. The complex is very stable in a wide range of pH; the adsorptive properties of Sc-EDTA in the batch studies and the retardation and recovery in the column tests in comparison with tritiated water are quite satisfactory. In general Sc-46-EDTA is a promising tracer for groundwater studies. In the report the appropriate conditions, procedures and some rational and efficient methods for testing the purity of Sc-46-EDTA in the preparation of the tracer solution of Sc-46-EDTA are described. In addition, it has been found that the formation of the metal hydroxide colloids is the major reason for the great loss in groundwater aquifers of most trivalent metal nuclide tracers in the cationic form including scandium-46. (author). 29 refs, 11 figs, 12 tabs

  13. 15N tracer kinetic studies on the validity of various 15N tracer substances for determining whole-body protein parameters in very small preterm infants

    International Nuclear Information System (INIS)

    Plath, C.; Heine, W.; Wutzke, K.D.; Krienke, L.; Toewe, J.M.; Massute, G.; Windischmann, C.

    1987-01-01

    Reliable 15 N tracer substances for tracer kinetic determination of whole-body protein parameters in very small preterm infants are still a matter of intensive research, especially after some doubts have been raised about the validity of [ 15 N]glycine, a commonly used 15 N tracer. Protein turnover, synthesis, breakdown, and further protein metabolism data were determined by a paired comparison in four preterm infants. Their post-conceptual age was 32.2 +/- 0.8 weeks, and their body weight was 1670 +/- 181 g. Tracer substances applied in this study were a [ 15 N]amino acid mixture (Ia) and [ 15 N]glycine (Ib). In a second group of three infants with a post conceptual age of 15 N-labeled 32.0 +/- 1.0 weeks and a body weight of 1,907 +/- 137 g, yeast protein hydrolysate (II) was used as a tracer substance. A three-pool model was employed for the analysis of the data. This model takes into account renal and fecal 15 N losses after a single 15 N pulse. Protein turnovers were as follows: 11.9 +/- 3.1 g kg-1 d-1 (Ia), 16.2 +/- 2.5 g kg-1 d-1 (Ib), and 10.8 +/- 3.0 g kg-1 d-1 (II). We were able to demonstrate an overestimation of the protein turnover when Ib was used. There was an expected correspondence in the results obtained from Ia and II. The 15 N-labeled yeast protein hydrolysate is a relatively cheap tracer that allows reliable determination of whole-body protein parameters in very small preterm infants

  14. An overview of application of bayesian classifier approach in radioactive tracer technology.case study

    International Nuclear Information System (INIS)

    El-Aseer, A.; Dawood, E.; Ben Ayad, S.; Alwerfalli, M.

    2015-01-01

    The usefulness of implementing a radioactive tracer techniques subjected to varied risk factors. Thus, the setup procedure for the application experimental techniques of radioactive tracer must be evaluated prior the decision action steps. One way of doing this, is to use Bay's theorem techniques. As there is a possibility of classifying the implemented parameters into certain catogries depending on their certainty to effect radioactive tracer technology. In this paper, the radioactive tracer experimental parameters classified accoring to Bayesian theory. Using this theory, one can study the proposed technical systems to determine the probabilities of the effectiveness of any selected parameter among the others. The classification of the applied experimental parameters into suitable or unsuitable in proposed theoretically. Ten parameters used in this experimental data were classified accordingly. The posterior is calculate from the prior and the likelihood previously determined by bayes rule.(author)

  15. Rate tracer studies of heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J; Kiang, S

    1977-10-01

    An analysis is presented of the extent to which parameters involved in transient tracing of isotopic species in heterogeneous catalysis can be determined by experiments in which tracer concentrations are measured as a function of time. Different treatments for open and closed systems with the over-all reaction at equilibrium or irreversible were developed.

  16. A Study Plan for Determining Recharge Rates at the Hanford Site Using Environmental Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, E. M.; Szecsody, J. E.; Phillips, S. J.

    1991-02-01

    This report presents a study plan tor estimating recharge at the Hanford Site using environmental tracers. Past operations at the Hanford Site have led to both soil and groundwater contamination, and recharge is one of the primary mechanisms for transporting contaminants through the vadose zone and into the groundwater. The prediction of contaminant movement or transport is one aspect of performance assessment and an important step in the remedial investigation/feasibility study (RI/FS) process. In the past, recharge has been characterized by collecting lysimeter data. Although lysimeters can generate important and reliable data, their limitations include 1) fixed location, 2) fixed sediment contents, 3) edge effects, 4) low rates, and 5) relatively short duration of measurement. These limitations impact the ability to characterize the spatial distribution of recharge at the Hanford Site, and thus the ability to predict contaminant movement in the vadose zone. An alternative to using fixed lysimeters for determining recharge rates in the vadose zone is to use environmental tracers. Tracers that have been used to study water movement in the vadose zone include total chloride, {sup 36}CI, {sup 3}H, and {sup 2}H/{sup 18}O. Atmospheric levels of {sup 36}CI and {sup 3}H increased during nuclear bomb testing in the Pacific, and the resulting "bomb pulse" or peak concentration can be measured in the soil profile. Locally, past operations at the Hanford Site have resu~ed in the atmospheric release of numerous chemical and isotopic tracers, including nitrate, {sup 129}I, and {sup 99}Tc. The radionuclides, in particular, reached a well-defined atmospheric peak in 1945. Atmospheric releases of {sup 129}I and {sup 99}Tc were greatly reduced by mid-1946, but nitrogen oxides continued to be released from the uranium separations facilities. As a result, the nitrate concentrations probably peaked in the mid-1950s, when the greatest number of separations facilities were operating

  17. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  18. Fluctuation theorem for an optically trapped tracer in dense colloids. A simulation study

    Directory of Open Access Journals (Sweden)

    Puertas Antonio M.

    2013-03-01

    Full Text Available The work supplied by an external parabolic potential that traps one tracer in a colloidal system is studied in this work by computer simulations. The density of the bath is changed from zero up to values close to the glass transition, and the velocity varies over several decades from the linear behaviour in the low Peclet limit to the high Peclet limit. The work distributions are analyzed using the model for the isolated Brownian partice, where the friction coefficient and temperature of the medium have been fitted to reproduce the position distribution of the tracer in the trap. The overall agreement is good but not perfect. The region of negative works is studied in more detail using the predictions of the fluctuation theorem, finding good qualitative agreement with the model of the isolated Brownian particle. The present results indicate that the fluctuation theorem is of application in cases where the tracer dynamics is complex, as predicted by theoretical works.

  19. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    International Nuclear Information System (INIS)

    Stetzenbach, K.; Farnham, I.

    1996-01-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability of these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test

  20. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stetzenbach, K.; Farnham, I.

    1996-06-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability of these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test.

  1. Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Afshar-Oromieh, A.; Haberkorn, U.; Schlemmer, H.P.; Fenchel, M.; Roethke, M.; Eder, M.; Eisenhut, M.; Hadaschik, B.A.; Kopp-Schneider, A.

    2014-01-01

    68 Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the 68 Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUV mean values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific 68 Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully. (orig.)

  2. Characterization of crushed tuff for the evaluation of the fate of tracers in transport studies in the unsaturated zone

    International Nuclear Information System (INIS)

    Polzer, W.L.; Fuentes, H.R.; Raymond, R.; Bish, D.L.; Gladney, E.S.; Lopez, E.A.

    1987-03-01

    Results of field-scale (caisson) transport studies under unsaturated moisture and steady and nonsteady flow conditions indicate variability and a lack of conservation of mass in solute transport. The tuff materials used in that study were analyzed for the presence of tracers and of freshly precipitated material to help explain the variability and lack of conservation of mass. Selected tuff samples were characterized by neutron activation analysis for tracer identification, by x-ray diffraction for mineral identification, by petrographic analysis for identification of freshly precipitated material, and by x-ray fluorescence analysis for identification of major and trace elements. The results of these analyses indicate no obvious presence of freshly precipitated material that would retard tracer movement. The presence of the nonsorbing tracers (bromide and iodide) suggest the retention of these tracers in immobile water. The presence of the nonsorbing tracers (bromide and iodide) suggest the retention of these tracers in immobile water. The presence of sorbing and nonsorbing tracers on the tuff at some locations (even cesium at the 415-cm depth) and not at others suggests variability in transport. 15 refs., 14 figs., 9 tabs

  3. The best of nuclear cardiology and MRI in 2003

    International Nuclear Information System (INIS)

    Daou, D.

    2005-01-01

    As in previous years, the year 2003 was notable for clinical studies confirming the position occupied by Nuclear Cardiology and MRI in patient management. This was confirmed in the different areas tackled this year. In myocardial ischaemia, 2 points attracted our attention. Firstly, there is the good prognostic value of a normal myocardial perfusion (stress) CT with tetrofosmin (Myoview), which makes the good prognostic value of a normal SPECT independent of the type of tracer used ( 201 Tl, 99m Tc - MIBI, 99m Tc - Tetrofosmine). Secondly, an elegant study performed in 10627 patients, once more confirming the significance of using stress SPECT in the therapeutic strategy (medical treatment versus revascularization). Furthermore, in the area of myocardial infarction (MI), 3 points attracted our attention : the use of Annexin A5 - 99m Tc was advantageous for visualizing apoptosis in the territory at risk, the limits of studying regional myocardial function versus contrast MRI in the diagnosis of MI, and the good sensitivity of contrast MRI in the detection of sub-endocardial MI. In the diagnosis of acute coronary syndrome, one study reported the sensitivity and specificity of emergency MRI (84 versus 85%). In the area of myocardial viability, one study reported the inferiority of electromechanical mapping compared to SPECT and positron emission tomography. In the area of post-infarct cardiac failure, studies have confirmed the place of LVEF in the evaluation of prognosis, and combining this with BNP and possibly the study of the angiotensin converting enzyme gene. Similarly another study reported the superiority of MIBG-1231 compared to cardiac frequency variability in the evaluation of prognosis. (author)

  4. Compilation and analyses of results from cross-hole tracer tests with conservative tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Nordqvist, Rune; Harrstroem, Johan (Geosigma AB (Sweden))

    2010-09-15

    Radionuclide transport in hydrogeological formations is one of the key factors for the safety analysis of a future repository of nuclear waste. Tracer tests have therefore been an important field method within the SKB investigation programmes at several sites since the late 1970's. This report presents a compilation and analyses of results from cross-hole tracer tests with conservative tracers performed within various SKB investigations. The objectives of the study are to facilitate, improve and reduce uncertainties in predictive tracer modelling and to provide supporting information for SKB's safety assessment of a final repository of nuclear waste. More specifically, the focus of the report is the relationship between the tracer mean residence time and fracture hydraulic parameters, i.e. the relationship between mass balance aperture and fracture transmissivity, hydraulic diffusivity and apparent storativity. For 74 different combinations of pumping and injection section at six different test sites (Studsvik, Stripa, Finnsjoen, Aespoe, Forsmark, Laxemar), estimates of mass balance aperture from cross-hole tracer tests as well as transmissivity were extracted from reports or in the SKB database Sicada. For 28 of these combinations of pumping and injection section, estimates of hydraulic diffusivity and apparent storativity from hydraulic interference tests were also found. An empirical relationship between mass balance aperture and transmissivity was estimated, although some uncertainties for individual data exist. The empirical relationship between mass balance aperture and transmissivity presented in this study deviates considerably from other previously suggested relationships, such as the cubic law and transport aperture as suggested by /Dershowitz and Klise 2002/, /Dershowitz et al. 2002/ and /Dershowitz et al. 2003/, which also is discussed in this report. No clear and direct empirical relationship between mass balance aperture and hydraulic

  5. Air pollution tracer studies in the lower atmosphere (citations from the NTIS data base). Report for 1964-Jan 80

    International Nuclear Information System (INIS)

    Cavagnaro, D.M.

    1980-02-01

    The cited reports cover research on the use of tracers to study lower atmospheric air pollution movements. The tracer used include sulfur hexafluoride, krypton 85, carbon 14, and other radioactive isotopes. The studies cite the results and techniques used, tracer movement from nuclear power plants, industrial stacks, urban areas, and the detectors used in their measurement

  6. Studies of 15N transamination following application of various tracer substances. 1

    International Nuclear Information System (INIS)

    Schadereit, R.; Krawielitzki, K.; Herrmann, U.

    1986-01-01

    4 groups of 3 growing Wistar rats each were orally given 15 N-labelled methionine, lysine, glycine and ammonia sulphate, resp., over 10 days. Measuring the 15 N accumulation in the amino acids (AA) of the body protein, the transamination of the individual 15 N substances and thus their suitability as tracer substances for studies of N metabolism was determined. None of the tested 15 N-AA achieved a proportionate labelling of all AA of the body protein. The AA used as tracer in each case showed the highest 15 N labelling. Of the amino- 15 N detected in the animal body, about 19% were found in Met after 15 N Met application, 88% in Lys after 15 N Lys application and 50% in Gly after 15 N Gly application. After the application of 15 N-ammonia sulphate about 42% of the body amino- 15 N are apportioned to the essential and 58% to the non-essential AA. Thus, this substance produces a more proportional labelling of the essential and non-essential AA of the body protein than 15 N-Gly. The following quotas of the 15 N amounts applied were found in the AA of the animal bodies: tracer substance lysine 52%, glycine 32%, ammonia sulphate 24%, methionine 21%. After summing up the amino acid 15 N amounts in the animal body, eliminating in each case the tracer AA and taking into account the molecular weight of the AA, there was a good agreement of the intensity of the accumulation of 15 N in the individual AA, irrespective of the applied tracer substance. (author)

  7. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  8. Field ionization mass spectrometry (FIMS) applied to tracer studies and isotope dilution analysis

    International Nuclear Information System (INIS)

    Anbar, M.; Heck, H.d'A.; McReynolds, J.H.; St John, G.A.

    1975-01-01

    The nonfragmenting nature of field ionization mass spectrometry makes it a preferred technique for the isotopic analysis of multilabeled organic compounds. The possibility of field ionization of nonvolatile thermolabile materials significantly extends the potential uses of this technique beyond those of conventional ionization methods. Multilabeled tracers may be studied in biological systems with a sensitivity comparable to that of radioactive tracers. Isotope dilution analysis may be performed reliably by this technique down to picogram levels. These techniques will be illustrated by a number of current studies using multilabeled metabolites and drugs. The scope and limitations of the methodology are discussed

  9. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J S; Johnson, S E; Horne, R N; Jackson, P B [Pet. Eng. Dept., Stanford University; Culver, G G [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0000-12-30

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  10. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J.S.; Johnson, S.E.; Horne, R.N.; Jackson, P. B. [Pet. Eng. Dept., Stanford University; Culver, G.G. [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0001-01-01

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  11. Atmospheric tracer experiments for regional dispersion studies

    International Nuclear Information System (INIS)

    Heffter, J.L.; Ferber, G.J.

    1980-01-01

    Tracer experiments are being conducted to verify atmospheric transport and dispersion calculations at distances from tens to hundreds of km from pollutant sources. In one study, a 2 1/2 year sampling program has been carried out at 13 sites located 30 to 140 km from a source of 85 Kr at the Savannah River Plant in South Carolina. Average weekly concentrations as well as twice-daily concentrations were obtained. Sampling data and meteorological data, including surface, tower, and rawinsonde observations are available on magnetic tape for model verification studies. Some verification results for the Air Resources Laboratories Atmospheric Transort and Dispersion Model (ARL-ATAD) are shown for averaging periods from one week to two years

  12. Comparison of PET/CT and PET/MRI hybrid systems using a {sup 68}Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, A. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Haberkorn, U. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Clinical Cooperation Unit of Nuclear Medicine, Heidelberg (Germany); Schlemmer, H.P.; Fenchel, M.; Roethke, M. [German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Eder, M.; Eisenhut, M. [German Cancer Research Center (DKFZ), Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Hadaschik, B.A. [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Kopp-Schneider, A. [German Cancer Research Center (DKFZ), Department of Biostatistics, Heidelberg (Germany)

    2014-05-15

    {sup 68}Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the {sup 68}Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUV{sub mean} values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific {sup 68}Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully. (orig.)

  13. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  14. Improved evaluation of antivascular cancer therapy using constrained tracer-kinetic modeling for multi-agent dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Hectors, Stefanie; Jacobs, Igor; Lok, Jasper; Peters, Johannes; Bussink, Johan; Hoeben, Freek J. M.; Keizer, Henk; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias; Strijkers, Gustav

    2018-01-01

    Dynamic contrast-enhanced MRI (DCE-MRI) is a promising technique for assessing the response of tumor vasculature to anti-vascular therapies. Multi-agent DCE-MRI employs a combination of low and high molecular weight contrast agents, which potentially improves the accuracy of estimation of tumor

  15. Study of the mineralization of coral implanted in vivo by radioactive tracers

    International Nuclear Information System (INIS)

    Irigaray, J.L.; Sauvage, T.; Oudadesse, H.; El Fadl, H.; Lefaivre, J.; Barlet, J.P.; Trevers, S.; Tixer, H.

    1993-01-01

    Coral has been used for the last ten years as bone substitution in the body because of its mechanical and osteoconductor properties. Primary studies have shown, for the first time, the quantitative behaviour of the atomic components. A biocoral implanted 'in vivo' was studied by some physical method of analysis. The natural biocorals used are the calcium carbonated exoskeletons built by Madrepian coral polyps. Neutron activation analysis showed that initial coral, essentially CaCO 3 , becomes a new material which has a mineral composition close to that of bone. The calcification mechanism of this implant was studied by using radioactive tracers. The tracer kinetics of calcium biomaterial have been established in the blood circuit and its use was shown by the organism for skeleton mineralization. (author) 8 refs.; 6 figs.; 4 tabs

  16. Radiochemical tracers in marine biology

    International Nuclear Information System (INIS)

    Petrocelli, S.R.; Anderson, J.W.; Neff, J.M.

    1977-01-01

    Tracers have been used in a great variety of experimentation. More recently, labeled materials have been applied in marine biological research. Some of the existing tracer techniques have been utilized directly, while others have been modified to suit the specific needs of marine biologists. This chapter describes some of the uses of tracers in marine biological research. It also mentions the problems encountered as well as offering possible solutions and discusses further applications of these techniques. Only pertinent references are cited and additional information may be obtained by consulting these references. Due to their relative ease of maintenance, freshwater species are also utilized in studies which involve radiotracer techniques. Since most of these techniques e directly applicable to marine species, some of these studies will also be included

  17. Modelling and tracer studies of atmospheric dispersion and deposition in regions of complex topography

    International Nuclear Information System (INIS)

    Norden, C.E.

    1981-11-01

    An indium tracer aerosol generating apparatus based on an alcohol/oxygen burner, and an analytical procedure by which filter samples containing tracer material could be analysed quantitatively by means of neutron activation analysis, were developed for use in atmospheric dispersion and deposition studies. A number of series of atmospheric dispersion experiments were conducted in the Richards Bay and Koeberg- Cape Town areas. The results are given, comparing the airbone tracer concentrations measured at ground level with values predicted by means of a numerical model, utilising two to three schemes, varying in sophistication, for calculating the dispersion coefficients. Recommendations are given regarding a dispersion model and dispersion coefficients for regular use in the Koeberg area, and ways for estimating plume trajectories

  18. Tracers of air-sea gas exchange

    International Nuclear Information System (INIS)

    Liss, P.S.

    1988-01-01

    The flux of gas across the air-sea interface is determined by the product of the interfacial concentration difference driving the exchange and a rate constant, often termed the transfer velocity. The concentration-difference term is generally obtained by direct measurement, whereas more indirect approaches are required to estimate the transfer velocity and its variation as a function of controlling parameters such as wind and sea state. Radioactive tracers have proved particularly useful in the estimation of air-sea transfer velocities and, recently, stable purposeful tracers have also started to be used. In this paper the use of the following tracers to determine transfer velocities at the sea surface is discussed: natural and bomb-produced 14 C, dissolved oxygen, 222 Rn and sulphur hexafluoride. Other topics covered include the relation between transfer velocity and wind speed as deduced from tracer and wind-tunnel studies, and the discrepancy between transfer velocities determined by using tracers and from eddy correlation measurements in the atmosphere. (author)

  19. Choice of infusion-sampling mode for tracer studies of free fatty acid metabolism

    International Nuclear Information System (INIS)

    Jensen, M.D.; Rogers, P.J.; Ellman, M.G.; Miles, J.M.

    1988-01-01

    To determine the preferred infusion-sampling mode for isotopic studies of free fatty acid (FFA) metabolism, tracer [( 14 C]palmitate) was infused into the left ventricle of five anesthetized dogs, and tracee ([ 3 H]palmitate) was infused into three separate peripheral veins of each dog. The [ 14 C]palmitate specific activity (SA) was lower in mixed venous than arterial blood, and [ 3 H]palmitate SA was equal in both sites. The actual infusion rate of [ 3 H]palmitate [2.15 +/- 0.31 X 10(5) disintegrations/min (dpm).kg-1.min-1] could be accurately predicted (2.14 +/- 0.32 X 10(5) dpm.kg-1.min-1) using the known [ 14 C]palmitate infusion rate and the arterial plasma [ 14 C]-to-[ 3 H]palmitate ratio. In contrast, the mixed venous [ 14 C]-to-[ 3 H]palmitate ratio resulted in overestimates (P less than 0.05) of the actual [ 3 H]palmitate infusion rate. In summary, venous tracer infusion with arterial blood sampling for FFA tracer studies provides the most accurate estimates of tracee rate of appearance

  20. Preparation of radioactive tracer for studying sediment movement

    International Nuclear Information System (INIS)

    Hussain, S.D.; Ghauri, G.A.; Qureshi, M.H.; Khan, N.A.

    1983-06-01

    In order to study the movement of sediment in harbours, estuaries and streams, artificial sediment in the form of glass is prepared. A preselected nuclide is added to the glass during its manufacture. The density and size distribution of the glass particles is method with that of the natural sediment. The activation of the artificial sediment in a reactor changes the nuclide into a radioactive isotope thereby tagging it and making it possible to trace its movement with suitable radiation detector. The method of tracer preparation is described with special reference to sadiment movement studies at Karachi harbour. (authors)

  1. Tracer filamentation at an unstable ocean front

    Science.gov (United States)

    Feng, Yen Chia; Mahadevan, Amala; Thiffeault, Jean-Luc; Yecko, Philip

    2017-11-01

    A front, where two bodies of ocean water with different physical properties meet, can become unstable and lead to a flow with high strain rate and vorticity. Phytoplankton and other oceanic tracers are stirred into filaments by such flow fields, as can often be seen in satellite imagery. The stretching and folding of a tracer by a two-dimensional flow field has been well studied. In the ocean, however, the vertical shear of horizontal velocity is typically two orders of magnitude larger than the horizontal velocity gradient. Theoretical calculations show that vertical shear alters the way in which horizontal strain affects the tracer, resulting in thin, sloping structures in the tracer field. Using a non-hydrostatic ocean model of an unstable ocean front, we simulate tracer filamentation to identify the effect of vertical shear on the deformation of the tracer. In a complementary laboratory experiment, we generate a simple, vertically sheared strain flow and use dye and particle image velocimetry to quantify the filamentary structures in terms of the strain and shear. We identify how vertical shear alters the tracer filaments and infer how the evolution of tracers in the ocean will differ from the idealized two-dimensional paradigm. Support of NSF DMS-1418956 is acknowledged.

  2. A new integrated dual time-point amyloid PET/MRI data analysis method

    International Nuclear Information System (INIS)

    Cecchin, Diego; Zucchetta, Pietro; Turco, Paolo; Bui, Franco; Barthel, Henryk; Tiepolt, Solveig; Sabri, Osama; Poggiali, Davide; Cagnin, Annachiara; Gallo, Paolo; Frigo, Anna Chiara

    2017-01-01

    In the initial evaluation of patients with suspected dementia and Alzheimer's disease, there is no consensus on how to perform semiquantification of amyloid in such a way that it: (1) facilitates visual qualitative interpretation, (2) takes the kinetic behaviour of the tracer into consideration particularly with regard to at least partially correcting for blood flow dependence, (3) analyses the amyloid load based on accurate parcellation of cortical and subcortical areas, (4) includes partial volume effect correction (PVEC), (5) includes MRI-derived topographical indexes, (6) enables application to PET/MRI images and PET/CT images with separately acquired MR images, and (7) allows automation. A method with all of these characteristics was retrospectively tested in 86 subjects who underwent amyloid ( 18 F-florbetaben) PET/MRI in a clinical setting (using images acquired 90-110 min after injection, 53 were classified visually as amyloid-negative and 33 as amyloid-positive). Early images after tracer administration were acquired between 0 and 10 min after injection, and later images were acquired between 90 and 110 min after injection. PVEC of the PET data was carried out using the geometric transfer matrix method. Parametric images and some regional output parameters, including two innovative ''dual time-point'' indexes, were obtained. Subjects classified visually as amyloid-positive showed a sparse tracer uptake in the primary sensory, motor and visual areas in accordance with the isocortical stage of the topographic distribution of the amyloid plaque (Braak stages V/VI). In patients classified visually as amyloid-negative, the method revealed detectable levels of tracer uptake in the basal portions of the frontal and temporal lobes, areas that are known to be sites of early deposition of amyloid plaques that probably represented early accumulation (Braak stage A) that is typical of normal ageing. There was a strong correlation between age

  3. A new integrated dual time-point amyloid PET/MRI data analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Cecchin, Diego; Zucchetta, Pietro; Turco, Paolo; Bui, Franco [University Hospital of Padua, Nuclear Medicine Unit, Department of Medicine - DIMED, Padua (Italy); Barthel, Henryk; Tiepolt, Solveig; Sabri, Osama [Leipzig University, Department of Nuclear Medicine, Leipzig (Germany); Poggiali, Davide; Cagnin, Annachiara; Gallo, Paolo [University Hospital of Padua, Neurology, Department of Neurosciences (DNS), Padua (Italy); Frigo, Anna Chiara [University Hospital of Padua, Biostatistics, Epidemiology and Public Health Unit, Department of Cardiac, Thoracic and Vascular Sciences, Padua (Italy)

    2017-11-15

    In the initial evaluation of patients with suspected dementia and Alzheimer's disease, there is no consensus on how to perform semiquantification of amyloid in such a way that it: (1) facilitates visual qualitative interpretation, (2) takes the kinetic behaviour of the tracer into consideration particularly with regard to at least partially correcting for blood flow dependence, (3) analyses the amyloid load based on accurate parcellation of cortical and subcortical areas, (4) includes partial volume effect correction (PVEC), (5) includes MRI-derived topographical indexes, (6) enables application to PET/MRI images and PET/CT images with separately acquired MR images, and (7) allows automation. A method with all of these characteristics was retrospectively tested in 86 subjects who underwent amyloid ({sup 18}F-florbetaben) PET/MRI in a clinical setting (using images acquired 90-110 min after injection, 53 were classified visually as amyloid-negative and 33 as amyloid-positive). Early images after tracer administration were acquired between 0 and 10 min after injection, and later images were acquired between 90 and 110 min after injection. PVEC of the PET data was carried out using the geometric transfer matrix method. Parametric images and some regional output parameters, including two innovative ''dual time-point'' indexes, were obtained. Subjects classified visually as amyloid-positive showed a sparse tracer uptake in the primary sensory, motor and visual areas in accordance with the isocortical stage of the topographic distribution of the amyloid plaque (Braak stages V/VI). In patients classified visually as amyloid-negative, the method revealed detectable levels of tracer uptake in the basal portions of the frontal and temporal lobes, areas that are known to be sites of early deposition of amyloid plaques that probably represented early accumulation (Braak stage A) that is typical of normal ageing. There was a strong correlation between

  4. A 82Br tracer study of coastal groundwater movement at Hat Head, NSW

    International Nuclear Information System (INIS)

    Hughes, C.; Stone, D.

    2003-01-01

    At Hat Head, NSW, on the eastern Australian coast, a radioisotope tracer study of groundwater flow in response to tidal forcing was conducted adjacent to a tidal creek. Using radiotracer, 82 Br, groundwater movement was tracked in-situ over 5 days on two occasions encompassing both neap and spring tide conditions. The tracer was injected into one borehole and gamma counts monitored from an adjacent borehole using NaI(Th) detectors. This technique maps the path of the slow moving tracer without sampling and allows the net groundwater movement to be distinguished from short term tidally driven fluxes. During the neap tide period net groundwater movement of 0.1 m/d was observed with horizontal tidal fluctuations in the order of 0.04 m. This contrasts with the tidally dominated spring tide period where net groundwater movement was negligible but tidally driven fluctuations of up to 0.13 m were observed

  5. Nuclear medicine and imaging research (quantitative studies in radiopharmaceutical science)

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, M.; Beck, R.N.

    1992-06-01

    This report describes three studies aimed at using radiolabeled pharmaceuticals to explore brain function and anatomy. The first section describes the chemical preparation of (F18)fluorinated benzamides (dopamine D-2 receptor tracers), (F18)fluorinated benzazepines (dopamine D-1 receptor tracers), and tissue distribution of (F18)-fluoxetine (serotonin reuptake site tracer). The second section relates pharmacological and behavioral studies of amphetamines. The third section reports on progress made with processing of brain images from CT, MRI and PET/SPECT with regards to brain metabolism of glucose during mental tasks.

  6. Nuclear medicine and imaging research (quantitative studies in radiopharmaceutical science)

    International Nuclear Information System (INIS)

    Cooper, M.; Beck, R.N.

    1992-06-01

    This report describes three studies aimed at using radiolabeled pharmaceuticals to explore brain function and anatomy. The first section describes the chemical preparation of [F18]fluorinated benzamides (dopamine D-2 receptor tracers), [F18]fluorinated benzazepines (dopamine D-1 receptor tracers), and tissue distribution of [F18]-fluoxetine (serotonin reuptake site tracer). The second section relates pharmacological and behavioral studies of amphetamines. The third section reports on progress made with processing of brain images from CT, MRI and PET/SPECT with regards to brain metabolism of glucose during mental tasks

  7. Simplification of complex kinetic models used for the quantitative analysis of nuclear magnetic resonance or radioactive tracer studies

    International Nuclear Information System (INIS)

    Schuster, R.; Schuster, S.; Holzhuetter, H.-G.

    1992-01-01

    A method for simplifying the mathematical models describing the dynamics of tracers (e.g. 13 C, 31 P, 14 C, as used in NMR studies or radioactive tracer experiments) in (bio-)chemical reaction systems is presented. This method is appropriate in the cases where the system includes reactions, the rates of which differ by several orders of magnitude. The basic idea is to adapt the rapid-equilibrium approximation to tracer systems. It is shown with the aid of the Perron-Frobenius theorem that for tracer systems, the conditions for applicability of this approximation are satisfied whenever some reactions are near equilibrium. It turns out that the specific enrichments of all of the labelled atoms that are connected by fast reversible reactions can be grouped together as 'pool variables'. The reduced system contains fewer parameters and can, thus, be fitted more easily to experimental data. Moreover, the method can be employed for identifying non-equilibrium and near-equilibrium reactions from experimentally measured specific enrichments of tracer. The reduction algorithm is illustrated by studying a model of the distribution of 13 C-tracers in the pentose phosphate pathway. (author)

  8. Imaging tools to study pharmacology: functional MRI on small rodents

    OpenAIRE

    Elisabeth eJonckers; Disha eShah; Julie eHamaide; Marleen eVerhoye; Annemie eVan Der Linden

    2015-01-01

    Functional Magnetic Resonance Imaging (fMRI) is an excellent tool to study the effect of pharmacological modulations on brain function in a non-invasive and longitudinal manner. We introduce several blood oxygenation level dependent (BOLD) fMRI techniques, including resting state (rsfMRI), stimulus-evoked (st-fMRI), and pharmacological MRI (phMRI). Respectively, these techniques permit the assessment of functional connectivity during rest as well as brain activation triggered by sensory stimu...

  9. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  10. Tracer monitoring of enhanced oil recovery projects

    Directory of Open Access Journals (Sweden)

    Kleven R.

    2013-05-01

    Full Text Available In enhanced oil recovery (EOR, chemicals are injected into the oil reservoir, either to increase macroscopic sweep efficiency, or to reduce remaining oil saturation in swept zones. Tracers can be used to identify reservoirs that are specifically suited for EOR operations. Injection of a selection of partitioning tracers, combined with frequent sample analysis of produced fluids, provides information suited for estimation of residual oil saturation. Tracers can also be used to evaluate and optimize the application of EOR chemicals in the reservoir. Suitable tracers will follow the EOR chemicals and assist in evaluation of retention, degradation or trapping. In addition to field applications, tracers also have a large potential as a tool to perform mechanistic studies of EOR chemicals in laboratory experiments. By labelling EOR chemicals with radioactive isotopes of elements such as H, C and S, detailed studies of transport mechanisms can be carried out. Co-injection of labelled compounds in dynamic flooding experiments in porous media will give information about retention or separation of the unique compounds constituting the chemical formulation. Separation of such compounds may be detrimental to obtaining the EOR effect expected. The paper gives new information of specific methods, and discusses current status for use of tracers in EOR operations.

  11. Assessment of apical periodontitis by MRI. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Geibel, M.A. [Ulm Univ. (Germany). Oral and Maxillofacial Surgery; Schreiber, E.S.; Bracher, A.K.; Rasche, V. [Ulm Univ. (Germany). Internal Medicine II; Hell, E.; Ulrici, J. [Sirona Dental Systems GmbH, Bensheim (Germany). Dental Imaging; Sailer, L.K. [DOC Praxisklinik im Wiley, Neu-Ulm (Germany). MKG; Ozpeynirci, Y. [Ulm Univ. (Germany). Diagnostic and Interventional Radiology

    2015-04-15

    The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). 19 consecutive patients (average age 43 ± 13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap. No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions.

  12. Assessment of apical periodontitis by MRI. A feasibility study

    International Nuclear Information System (INIS)

    Geibel, M.A.; Schreiber, E.S.; Bracher, A.K.; Rasche, V.; Hell, E.; Ulrici, J.; Sailer, L.K.; Ozpeynirci, Y.

    2015-01-01

    The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). 19 consecutive patients (average age 43 ± 13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap. No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions.

  13. Circulation of the medullary cerebrospinal fluid. Comparative study of various tracers

    International Nuclear Information System (INIS)

    Bok, B.; Thebault, B.; Cavailloles, F.; Aboulker, J.

    Gammamyelography is used to study the circulation of the cerebrospinal fluid in the perimedullary sub-arachoid spaces. Many radioactive preparations have been proposed for this examination which is designed to show up all dynamic perturbations of the CSF flux. Of the criteria governing the choice of tracer some importance given has been to the molecular diffusion constant of the preparation, iodinated albumine seeming the most suitable in this respect. An attempt was made to estimate the influence of molecular weight on the tracer kinetics by comparing three preparations injected simultaneously: indium 111-labelled siderophilline of M.W. above 100,000; iodine 131-labelled human serum albumine of MW around 70,000; sup(99m)Tc-labelled DTPA, a chelate of low molecular weight. The results showed no detectable influence of the molecular weight of these preparations on their intraspinal kinetics in the time taken for the examination. In practice this work justifies the use of the preparation most convenient and least harmful from the dosimetric viewpoint for the isotope and from the antigenic toxicological viewpoint for the tracer, which means that the replacement of iodinated albumine by indium-111 DTPA for example should be possible at least at the medullary level [fr

  14. Dynamic dual-tracer PET reconstruction.

    Science.gov (United States)

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  15. The use of tracer techniques in the study of soil water flows and contaminant transport

    International Nuclear Information System (INIS)

    Reeves, A.D.; Beven, K.J.

    1990-04-01

    This report reviews the use of different types of tracers in the characterisation of soil water flows and the implications of tracer studies for modelling contaminant transport. The tracers considered are a number of different anions, stable isotopes, radioactive tracers, organic dyes, fluorocarbons, gases, solid particles and water temperature. The theoretical basis for modelling the results of tracer experiments in terms of the traditional convective-dispersion equation (CDE) is outlined. A number of alternative modelling strategies are reviewed: the mobile/immobile water extension of the CDE; the Jury Transfer Function Model (TFM); the Aggregated Mixing Zone (AMZ) model and Random Particle Tracking models. The first will form the basis of the Systeme Hydrologique Europeen (SHE) contaminant transport component. The Jury and AMZ models are both linear models and are consequently limited to applications in which the flows may be considered to be quasi-steady or repeatable. Random particle tracking models have the advantage of both flexibility and applicability to transient and spatially variable flow domains. A random particle model is being implemented on a transputer workstation at Lancaster and will be used to explore the effect of sub-grid scale complexities on effective grid-scale parameter values for distributed models such as SHE. (author)

  16. Heat tracer methods

    Science.gov (United States)

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    The flow of heat in the subsurface is closely linked to the movement of water (Ingebritsen et al., 2006). As such, heat has been used as a tracer in groundwater studies for more than 100 years (Anderson, 2005). As with chemical and isotopic tracers (Chapter 7), spatial or temporal trends in surface and subsurface temperatures can be used to infer rates of water movement. Temperature can be measured accurately, economically, at high frequencies, and without the need to obtain water samples, facts that make heat an attractive tracer. Temperature measurements made over space and time can be used to infer rates of recharge from a stream or other surface water body (Lapham, 1989; Stonestrom and Constantz, 2003); measurements can also be used to estimate rates of steady drainage through depth intervals within thick unsaturated zones (Constantz et al., 2003; Shan and Bodvarsson, 2004). Several thorough reviews of heat as a tracer in hydrologic studies have recently been published (Constantz et al., 2003; Stonestrom and Constantz, 2003; Anderson, 2005; Blasch et al., 2007; Constantz et al., 2008). This chapter summarizes heat-tracer approaches that have been used to estimate recharge.Some clarification in terminology is presented here to avoid confusion in descriptions of the various approaches that follow. Diffuse recharge is that which occurs more or less uniformly across large areas in response to precipitation, infiltration, and drainage through the unsaturated zone. Estimates of diffuse recharge determined using measured temperatures in the unsaturated zone are referred to as potential recharge because it is possible that not all of the water moving through the unsaturated zone will recharge the aquifer; some may be lost to the atmosphere by evaporation or plant transpiration. Estimated fluxes across confining units in the saturated zone are referred to as interaquifer flow (Chapter 1). Focused recharge is that which occurs directly from a point or line source, such

  17. Imaging tools to study pharmacology: functional MRI on small rodents

    Directory of Open Access Journals (Sweden)

    Elisabeth eJonckers

    2015-10-01

    Full Text Available Functional Magnetic Resonance Imaging (fMRI is an excellent tool to study the effect of pharmacological modulations on brain function in a non-invasive and longitudinal manner. We introduce several blood oxygenation level dependent (BOLD fMRI techniques, including resting state (rsfMRI, stimulus-evoked (st-fMRI, and pharmacological MRI (phMRI. Respectively, these techniques permit the assessment of functional connectivity during rest as well as brain activation triggered by sensory stimulation and/or a pharmacological challenge. The first part of this review describes the physiological basis of BOLD fMRI and the hemodynamic response on which the MRI contrast is based. Specific emphasis goes to possible effects of anaesthesia and the animal’s physiological conditions on neural activity and the hemodynamic response. The second part of this review describes applications of the aforementioned techniques in pharmacologically-induced, as well as in traumatic and transgenic disease models and illustrates how multiple fMRI methods can be applied successfully to evaluate different aspects of a specific disorder. For example, fMRI techniques can be used to pinpoint the neural substrate of a disease beyond previously defined hypothesis-driven regions-of-interest (ROIs. In addition, fMRI techniques allow one to dissect how specific modifications (e.g. treatment, lesion etc. modulate the functioning of specific brain areas (st-fMRI, phMRI and how functional connectivity (rsfMRI between several brain regions is affected, both in acute and extended time frames. Furthermore, fMRI techniques can be used to assess/explore the efficacy of novel treatments in depth, both in fundamental research as well as in preclinical settings. In conclusion, by describing several exemplary studies, we aim to highlight the advantages of functional MRI in exploring the acute and long-term effects of pharmacological substances and/or pathology on brain functioning along with

  18. Tracer transport in fractured rocks

    International Nuclear Information System (INIS)

    Tsang, C.F.; Tsang, Y.W.; Hale, F.V.

    1988-07-01

    Recent interest in the safety of toxic waste underground disposal and nuclear waste geologic repositories has motivated many studies of tracer transport in fractured media. Fractures occur in most geologic formations and introduce a high degree of heterogeneity. Within each fracture, the aperture is not constant in value but strongly varying. Thus for such media, tracer tends to flow through preferred flowpaths or channels within the fractures. Along each of these channels, the aperture is also strongly varying. A detailed analysis is carried out on a 2D single fracture with variable apertures and the flow through channels is demonstrated. The channels defined this way are not rigidly set pathways for tracer transport, but are the preferred flow paths in the sense of stream-tubes in the potential theory. It is shown that such variable-aperture channels can be characterized by an aperture probability distribution function, and not by the exact deterministic geometric locations. We also demonstrate that the 2D tracer transport in a fracture can be calculated by a model of a system of 1D channels characterized by this distribution function only. Due to the channeling character of tracer transport in fractured rock, random point measurements of tracer breakthrough curves may give results with a wide spread in value due to statistical fluctuations. The present paper suggests that such a wide spread can probably be greatly reduced by making line/areal (or multiple) measurements covering a few spatial correlation lengths. 13 refs., 11 figs., 1 tab

  19. Dynamic MRI study for breast tumors

    International Nuclear Information System (INIS)

    Seki, Tsuneaki

    1990-01-01

    Application of MRI for diagnosis of breast tumors was retrospectively examined in 103 consecutive cases. Contrast enhancement, mostly by dynamic study, was performed in 83 cases using Gd-DTPA and 0.5 T superconductive apparatus. Results were compared to those of mammography and sonography. On dynamic study, carcinoma showed abrupt rise of signal intensity with clear-cut peak formation in early phase, while benign fibroadenoma showed slow rise of signal intensity and prolonged enhancement without peak formation. In 12 of 33 carcinomas (33%), peripheral ring enhancement was noted reflecting vascular stroma of histologic sections. All fibroadenomas showed homogenous enhancement without peripheral ring. In MRI, sensitivity, specificity, and accuracy were 86%, 96%, 91%. In mammography 82%, 95%, 87% and in ultrasonography 91%, 95%, 93%. Although MRI should not be regarded as routine diagnostic procedure because of expense and limited availability, it may afford useful additional information when standard mammographic findings are not conclusive. (author)

  20. Using radioactive tracer technique in municipal hygiene

    International Nuclear Information System (INIS)

    Yurasova, O.I.

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology

  1. Using radioactive tracer technique in municipal hygiene

    Energy Technology Data Exchange (ETDEWEB)

    Yurasova, O I [Institut Obshchej i Kommunal' noj Gigieny, Moscow (USSR)

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology.

  2. Tracers and tracing methods

    International Nuclear Information System (INIS)

    Leclerc, J.P.

    2001-01-01

    The first international congress on 'Tracers and tracing methods' took place in Nancy in May 2001. The objective of this second congress was to present the current status and trends on tracing methods and their applications. It has given the opportunity to people from different fields to exchange scientific information and knowledge about tracer methodologies and applications. The target participants were the researchers, engineers and technologists of various industrial and research sectors: chemical engineering, environment, food engineering, bio-engineering, geology, hydrology, civil engineering, iron and steel production... Two sessions have been planned to cover both fundamental and industrial aspects: 1)fundamental development (tomography, tracer camera visualization and particles tracking; validation of computational fluid dynamics simulations by tracer experiments and numerical residence time distribution; new tracers and detectors or improvement and development of existing tracing methods; data treatments and modeling; reactive tracer experiments and interpretation) 2)industrial applications (geology, hydrogeology and oil field applications; civil engineering, mineral engineering and metallurgy applications; chemical engineering; environment; food engineering and bio-engineering). The program included 5 plenary lectures, 23 oral communications and around 50 posters. Only 9 presentations are interested for the INIS database

  3. Radioisotope tracer applications in industry

    International Nuclear Information System (INIS)

    Rao, S.M.

    1987-01-01

    Radioisotope tracers have many advantages in industrial trouble-shooting and studies on process kinetics. The applications are mainly of two types: one leading to qualitative (Yes or No type) information and the other to quantitative characterisation of flow processes through mass balance considerations and flow models. ''Yes or No'' type methods are mainly used for leakage and blockage locations in pipelines and in other industrial systems and also for location of water seepage zones in oil wells. Flow measurements in pipelines and mercury inventory in electrolytic cells are good examples of tracer methods using the mass balance approach. Axial dispersion model and Tanks-in-Series model are the two basic flow models commonly used with tracer methods for the characterisation of kinetic processes. Examples include studies on flow processes in sugar crystallisers as well as in a precalcinator in a cement plant. (author). 18 figs

  4. Hydrodynamics of a commercial scale CFB boiler-study with radioactive tracer particles

    DEFF Research Database (Denmark)

    Lin, Weigang; Hansen, Peter F.B.; Dam-Johansen, Kim

    1999-01-01

    This paper presents the experimental results with radioactive tracer particles in an 80 MWth circulating fluidized-bed boiler. Batches of gamma-ray emitting tracer particles were injected into the standpipe. The response curves of the impulse injection were measured by a set of successive scintil...

  5. Tracer Testing for Estimating Heat Transfer Area in Fractured Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, Karsten; van Heel, Ton; Shan, Chao

    2004-05-12

    A key parameter governing the performance and life-time of a Hot Fractured Rock (HFR) reservoir is the effective heat transfer area between the fracture network and the matrix rock. We report on numerical modeling studies into the feasibility of using tracer tests for estimating heat transfer area. More specifically, we discuss simulation results of a new HFR characterization method which uses surface-sorbing tracers for which the adsorbed tracer mass is proportional to the fracture surface area per unit volume. Sorption in the rock matrix is treated with the conventional formulation in which tracer adsorption is volume-based. A slug of solute tracer migrating along a fracture is subject to diffusion across the fracture walls into the adjacent rock matrix. Such diffusion removes some of the tracer from the fluid in the fractures, reducing and retarding the peak in the breakthrough curve (BTC) of the tracer. After the slug has passed the concentration gradient reverses, causing back-diffusion from the rock matrix into the fracture, and giving rise to a long tail in the BTC of the solute. These effects become stronger for larger fracture-matrix interface area, potentially providing a means for estimating this area. Previous field tests and modeling studies have demonstrated characteristic tailing in BTCs for volatile tracers in vapor-dominated reservoirs. Simulated BTCs for solute tracers in single-phase liquid systems show much weaker tails, as would be expected because diffusivities are much smaller in the aqueous than in the gas phase, by a factor of order 1000. A much stronger signal of fracture-matrix interaction can be obtained when sorbing tracers are used. We have performed simulation studies of surface-sorbing tracers by implementing a model in which the adsorbed tracer mass is assumed proportional to the fracture-matrix surface area per unit volume. The results show that sorbing tracers generate stronger tails in BTCs, corresponding to an effective

  6. Application of tracer techniques in studies of sediment transport in Vietnam

    International Nuclear Information System (INIS)

    Hai, P.S.; Quang, N.H.; Xuan, N.M.; Chuong, P.N.; Hien, P.Z.

    1997-01-01

    As a consequence of intensive erosion processes typical of the humid tropical one, as well as of human activities destroying tropical forests, grasslands and protective mangrove swamps, etc, most navigable estuaries in Vietnam suffer seriously from sedimentation. In order to maintain the necessary depth for the 7.000 ton vessels entering and leaving ports, a large amount of money is spent annually on dredging operation. A lot of hydraulic and sedimentary surveys were carried out in the past by different groups of researchers. However, owing to the complexity of sediment processes in estuarine areas under the hydrometeorological conditions typical of the southwest Pacific, the use of just any modelling approach is not suitable. In many cases, the conclusions inferred from mathematical models have been the controversial matter. The tracer techniques, which have been employed in the country since 1991, have provided a very efficient tool to obtain a dynamic idea of sediment transport. Many investigations of bedload transport using Sc-46 labelled glass and Ir-192 glass as radioactive tracers were carried out from 1992 to 1996 at Haiphong harbour area. Bedload transport rates under effect of northeast monsoon and southeast monsoon at 5 zones located on both sides of the navigation channel were estimated. In bedload transport studies, apart from conventional methods for assessment of transport thickness, a new method using the ratio of photoelectric peak to Compton region of spectra acquired directly on the sea bed was put forward and applied. The influence of dredging materials at two dumping sites under different tidal phases on in fill rate in the access channel was assessed by radioactive tracers. The qualitative and quantitative information on sediment transport at some experimental sites given by tracers was used by modelling specialists who have undertaken hydraulic and sedimentary surveys in this region

  7. Brain activation studies with PET and functional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Yoshiharu [Fukui Medical Univ., Matsuoka (Japan). Biomedical Imaging Research Center; Sadato, Norihiro [Okazaki National Research Inst., Aichi (Japan). National Inst. for Physiological Sciences

    2002-01-01

    Application of PET and functional MRI in brain activation studies is reviewed. 3D-PET images obtained repeatedly after intravenous injection of about 370 MBq of H{sub 2}{sup 15}O can detect a faint blood flow change in the brain. Functional MRI can also detect the blood flow change in the brain due to blood oxygen level-dependent effect. Echo-planar imaging is popular in MRI with 1.5 or 3 T. Images are analyzed by statistical parametric mapping with correction of cerebral regions, anatomical normalization and statistics. PET data give the blood flow change by the H{sub 2}{sup 15}O incorporation into the brain and MRI data, by the scarce tissue oxygen consumption despite the change. Actual images during the cognition task-performance and of frequent artifacts are given. PET is suitable for studies of brain functions like sensibility and emotion and functional MRI, like cortex functions and clinical practices in identification of functional regions prior to surgery and evaluation of functional recovery of damaged brain. (K.H.)

  8. Brain activation studies with PET and functional MRI

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Sadato, Norihiro

    2002-01-01

    Application of PET and functional MRI in brain activation studies is reviewed. 3D-PET images obtained repeatedly after intravenous injection of about 370 MBq of H 2 15 O can detect a faint blood flow change in the brain. Functional MRI can also detect the blood flow change in the brain due to blood oxygen level-dependent effect. Echo-planar imaging is popular in MRI with 1.5 or 3 T. Images are analyzed by statistical parametric mapping with correction of cerebral regions, anatomical normalization and statistics. PET data give the blood flow change by the H 2 15 O incorporation into the brain and MRI data, by the scarce tissue oxygen consumption despite the change. Actual images during the cognition task-performance and of frequent artifacts are given. PET is suitable for studies of brain functions like sensibility and emotion and functional MRI, like cortex functions and clinical practices in identification of functional regions prior to surgery and evaluation of functional recovery of damaged brain. (K.H.)

  9. Underground flux studies in waste basin of CIPC using natural and artificial tracers - v.2

    International Nuclear Information System (INIS)

    Minardi, P.S.P.

    1982-10-01

    This report is a complement of the first volume and it has studies with natural tracers to be done on February and March/82, results and conclusions obtained with artificial tracers on March/82, every direction tests and flood course done up to october/82, besides mineralogical and complete qualitative analysis of soil obtained from sounding evidences done in mineral and industrial complex of Pocos de Caldas. (author)

  10. All-phase MR angiography using independent component analysis of dynamic contrast enhanced MRI time series. φ-MRA

    International Nuclear Information System (INIS)

    Suzuki, Kiyotaka; Matsuzawa, Hitoshi; Watanabe, Masaki; Nakada, Tsutomu; Nakayama, Naoki; Kwee, I.L.

    2003-01-01

    Dynamic contrast enhanced magnetic resonance imaging (dynamic MRI) represents a MRI version of non-diffusible tracer methods, the main clinical use of which is the physiological construction of what is conventionally referred to as perfusion images. The raw data utilized for constructing MRI perfusion images are time series of pixel signal alterations associated with the passage of a gadolinium containing contrast agent. Such time series are highly compatible with independent component analysis (ICA), a novel statistical signal processing technique capable of effectively separating a single mixture of multiple signals into their original independent source signals (blind separation). Accordingly, we applied ICA to dynamic MRI time series. The technique was found to be powerful, allowing for hitherto unobtainable assessment of regional cerebral hemodynamics in vivo. (author)

  11. Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

    International Nuclear Information System (INIS)

    Manber, Richard; Thielemans, Kris; Hutton, Brian; Barnes, Anna; Ourselin, Sebastien; Arridge, Simon; O’Meara, Celia; Atkinson, David

    2014-01-01

    Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution MRI to capture motion states during respiration [1, 2]. In this work, we use a respiratory signal derived from the PET list-mode data [3, ], with no requirement for an external device or MR sequence modifications.

  12. Using Diffusion Tractography to Predict Cortical Connection Strength and Distance: A Quantitative Comparison with Tracers in the Monkey

    DEFF Research Database (Denmark)

    Donahue, Chad J.; Sotiropoulos, Stamatios N.; Jbabdi, Saad

    2016-01-01

    of tractography for analyzing interareal corticocortical connectivity in nonhuman primates and a framework for assessing future tractography methodological refinements objectively. SIGNIFICANCE STATEMENT Tractography based on diffusion MRI has great potential for a variety of applications, including estimation......Tractography based on diffusion MRI offers the promise of characterizing many aspects of long-distance connectivity in the brain, but requires quantitative validation to assess its strengths and limitations. Here, we evaluate tractography's ability to estimate the presence and strength...... of connections between areas of macaque neocortex by comparing its results with published data from retrograde tracer injections. Probabilistic tractography was performed on high-quality postmortem diffusion imaging scans from two Old World monkey brains. Tractography connection weights were estimated using...

  13. The use of bromine as a tracer for studying infiltrations in mining processes

    International Nuclear Information System (INIS)

    Diaz, F; Andonie, O; Rojas, X

    2003-01-01

    The impact of mining activity on underground water is becoming increasingly important because of the scarcity of the resource and due to the different use if there is water under the mining. Once the resource is affected the source of infiltration should be identified in all the processes and systems that are involved in the production system in order to take the appropriate preventive or remedial measures, which should also be the most efficient ones. Tracers play an important role in studying infiltration from mining processes to underground bodies of water. Natural chemical and isotopic tracers can identify the hydrogeological setting and help to establish supported hypotheses about the possible origin of the infiltrations. After the different ideas about the processes or systems that could be infiltrated are presented, the application of additional artificial tracers can resolve any doubts This work presents the use of bromine as a tracer for such studies, because of its specific characteristics as a good tracer in water with low interaction in porous surroundings, generally, and its determination by Neutron Activation Analyzers (NAA) due to its low limits of detection and the technique's precision and accuracy for use at reasonable costs. Given that for this type of study a large number of samples are necessary and that it should be carried out in a time period that does not surpass the duration of the process (a few months), a change had to be made in the methodology usually used for the NAA, which included taking a fraction of significantly less sample while meeting the power requirements for differentiating small changes in concentrations between samples. With this modification a larger number of samples can be irradiated in available positions for these purposes in the RECH-1 and the requirements for the number of samples and response time can be met. After the practical performance of this modification, a comparison between both methodologies was carried

  14. Measurements of waste tank passive ventilation rates using tracer gases

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Olsen, K.B.; Sklarew, D.S.; Evans, J.C.; Remund, K.M.

    1997-09-01

    This report presents the results of ventilation rate studies of eight passively ventilated high-level radioactive waste tanks using tracer gases. Head space ventilation rates were determined for Tanks A-101, AX-102, AX-103, BY-105, C-107, S-102, U-103, and U-105 using sulfur hexafluoride (SF 6 ) and/or helium (He) as tracer gases. Passive ventilation rates are needed for the resolution of several key safety issues. These safety issues are associated with the rates of flammable gas production and ventilation, the rates at which organic salt-nitrate salt mixtures dry out, and the estimation of organic solvent waste surface areas. This tracer gas study involves injecting a tracer gas into the tank headspace and measuring its concentration at different times to establish the rate at which the tracer is removed by ventilation. Tracer gas injection and sample collection were performed by SGN Eurisys Service Corporation and/or Lockheed Martin Hanford Corporation, Characterization Project Operations. Headspace samples were analyzed for He and SF 6 by Pacific Northwest National Laboratory (PNNL). The tracer gas method was first demonstrated on Tank S-102. Tests were conducted on Tank S-102 to verify that the tracer gas was uniformly distributed throughout the tank headspace before baseline samples were collected, and that mixing was sufficiently vigorous to maintain an approximately uniform distribution of tracer gas in the headspace during the course of the study. Headspace samples, collected from a location about 4 in away from the injection point and 15, 30, and 60 minutes after the injection of He and SF 6 , indicated that both tracer gases were rapidly mixed. The samples were found to have the same concentration of tracer gases after 1 hour as after 24 hours, suggesting that mixing of the tracer gas was essentially complete within 1 hour

  15. Suitability of tracers

    International Nuclear Information System (INIS)

    Klotz, D.

    1999-01-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other [de

  16. Skeletal scintigraphy and quantitative tracer studies in metabolic bone disease

    Science.gov (United States)

    Fogelman, Ignac

    Bone scan imaging with the current bone seeking radiopharmaceuticals, the technetium-99m labelled diphosphonates, has dramatically improved our ability to evaluate skeletal pathology. In this thesis, chapter 1 presents a review of the history of bone scanning, summarises present concepts as to the mechanism of uptake of bone seeking agents and briefly illustrates the role of bone scanning in clinical practice. In chapter 2 the applications of bone scan imaging and quantitative tracer techniques derived from the bone scan in the detection of metabolic bone disease are discussed. Since skeletal uptake of Tc-99m diphosphonate depends upon skeletal metabolism one might expect that the bone scan would be of considerable value in the assessment of metabolic bone disease. However in these disorders the whole skeleton is often diffusely involved by the metabolic process and simple visual inspection of the scan image may not reveal the uniformly increased uptake of tracer. Certain patterns of bone scan abnormality have, however, been reported in patients with primary hyperparathyroidism and renal osteo-dystrophy; the present studies extend these observations and introduce the concept of "metabolic features" which are often recognisable in conditions with generalised increased bone turnover. As an aid to systematic recognition of these features on a given bone scan image a semi-quantitative scoring system, the metabolic index, was introduced. The metabolic index allowed differentiation between various groups of patients with metabolic disorders and a control population. In addition, in a bone scan study of patients with acromegaly, it was found that the metabolic index correlated well with disease activity as measured by serum growth hormone levels. The metabolic index was, however, found to be a relatively insensitive means of identifying disease in individual patients. Patients with increased bone turnover will have an absolute increase in skeletal uptake of tracer. As a

  17. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    International Nuclear Information System (INIS)

    El-Sherif, O; Xhaferllari, I; Gaede, S; Sykes, J; Butler, J; Wisenberg, G; Prato, F

    2015-01-01

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  18. TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherif, O; Xhaferllari, I; Gaede, S [Western Univeristy, London, ON (United Kingdom); London Regional Cancer Program, London, ON (United Kingdom); Sykes, J; Butler, J [Lawson Health Research Institute, London, ON (United Kingdom); Wisenberg, G; Prato, F [Western Univeristy, London, ON (United Kingdom); Lawson Health Research Institute, London, ON (United Kingdom)

    2015-06-15

    Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation

  19. Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study

    International Nuclear Information System (INIS)

    Rust, T C; Kadrmas, D J

    2006-01-01

    Blood flow and hypoxia are interrelated aspects of physiology that affect cancer treatment and response. Cu-PTSM and Cu-ATSM are related PET tracers for blood flow and hypoxia, and the ability to rapidly image both tracers in a single scan would bring several advantages over conventional single-tracer techniques. Using dynamic imaging with staggered injections, overlapping signals for multiple PET tracers may be recovered utilizing information from kinetics and radioactive decay. In this work, rapid dual-tracer PTSM+ATSM PET was simulated and tested as a function of injection delay, order and relative dose for several copper isotopes, and the results were compared relative to separate single-tracer data. Time-activity curves representing a broad range of tumour blood flow and hypoxia levels were simulated, and parallel dual-tracer compartment modelling was used to recover the signals for each tracer. The main results were tested further using a torso phantom simulation of PET tumour imaging. Using scans as short as 30 minutes, the dual-tracer method provided measures of blood flow and hypoxia similar to single-tracer imaging. The best performance was obtained by injecting PTSM first and using a somewhat higher dose for ATSM. Comparable results for different copper isotopes suggest that tracer kinetics with staggered injections play a more important role than radioactive decay in the signal separation process. Rapid PTSM+ATSM PET has excellent potential for characterizing both tumour blood flow and hypoxia in a single, fast scan, provided that technological hurdles related to algorithm development and routine use can be overcome

  20. Tracer Study Lulusan Program Studi Bimbingan dan Konseling Universitas Negeri Gorontalo

    Directory of Open Access Journals (Sweden)

    Maryam Rahim

    2018-01-01

    Full Text Available Penelitian ini diharapkan dapat memperbaiki dan meningkatkan kualitas pengelolaan program studi Bimbingan dan Konseling Universitas Negeri Gorontalo berdasarkan informasi yang diperoleh melalui tracer study. Secara khusus, penelitian ini dilakukan untuk memperoleh informasi tentang lulusan, yang meliputi (1 rata-rata masa tunggu lulusan, (2 jenis pekerjaan yang ditekuni, dan (3 tanggapan terhadap pengguna lulusan. Permasalahan penelitian ini adalah: (1 berapa rata-rata masa tunggu lulusan?, (2 jenis pekerjaan apa yang ditekuni lulusan?, dan (3 bagaimana tanggapan pengguna terhadap lulusan?. Anggota populasi dalam penelitian ini berjumlah 408 orang, dari jumlah tersebut 58% (238 orang dijadikan sebagai anggota sampel dengan menggunakan cluster sampling. Indikator penelitian meliputi: (1 rata-rata masa tunggu lulusan, (2 jenis pekerjaan yang ditekuni lulusan, dan (3 tanggapan pengguna terhadap lulusan. Pengumpulan data dilakukan dengan menggunakan instrumen tracer study. Data yang terkumpul dianalisis secara kuantitatif. Hasil penelitian menunjukkan: (1 rata-rata masa tunggu lulusan adalah 3 bulan; (2 jenis pekerjaan yang ditekuni lulusan terdiri dari 13 kategori yakni (a Guru BK (PNS sebanyak 27.31%; (b Guru BK (Non PNS sebanyak 50.00%; (c Guru PAUD sebanyak 0.84%; (d Guru TK sebanyak 5.04%; (e Guru SD sebanyak 4.20%; (f Guru SLB sebanyak 0.42%; (g Pegawai instansi pemerintah sebanyak 2.52%; (h Pegawai perusahaan sebanyak 0.84%; (i Dosen sebanyak 1.26%; (j Dosen luar biasa sebanyak 1.26%; (k Wirausaha sebanyak 3.78%; (l Anggota DPR sebanyak 0.42%; (m dan lain-lain sebanyak 2.10%; dan (3 tanggapan pengguna terhadap lulusan, yang menyangkut: (a  integritas (etika dan moral = 89.60 (sangat baik; (b keahlian berdasarkan bidang ilmu (profesionalisme = 82.92 (baik; (c bahasa Inggris = 67.89 (cukup; (d penggunaan teknologi informasi = 81.71 (baik; (e komunikasi = 84.06 (baik; (f kerjasama tim = 85.04 (sangat baik; dan (g pengembangan diri = 83.83 (baik

  1. Neurovascular coupling to D2/D3 dopamine receptor occupancy using simultaneous PET/functional MRI

    DEFF Research Database (Denmark)

    Sander, Christin Y; Hooker, Jacob M; Catana, Ciprian

    2013-01-01

    This study employed simultaneous neuroimaging with positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) to demonstrate the relationship between changes in receptor occupancy measured by PET and changes in brain activity inferred by fMRI. By administering the D2/D3...... dopamine receptor antagonist [(11)C]raclopride at varying specific activities to anesthetized nonhuman primates, we mapped associations between changes in receptor occupancy and hemodynamics [cerebral blood volume (CBV)] in the domains of space, time, and dose. Mass doses of raclopride above tracer levels...... caused increases in CBV and reductions in binding potential that were localized to the dopamine-rich striatum. Moreover, similar temporal profiles were observed for specific binding estimates and changes in CBV. Injection of graded raclopride mass doses revealed a monotonic coupling between neurovascular...

  2. New radioactive tracers can help find cause of jaundice

    International Nuclear Information System (INIS)

    Carrard, G.

    1987-01-01

    Radioactive tracers for the investigation of a condition known as persistent jaundice of the newborn, have been designed, prepared and tested at ANSTO. The tracers are chemical compounds of the radioactive elements gallium-67 and indium-111. They given lower radiation doses than the conventional radioactive tracer, iodine-131, used in these studies

  3. Packet Tracer network simulator

    CERN Document Server

    Jesin, A

    2014-01-01

    A practical, fast-paced guide that gives you all the information you need to successfully create networks and simulate them using Packet Tracer.Packet Tracer Network Simulator is aimed at students, instructors, and network administrators who wish to use this simulator to learn how to perform networking instead of investing in expensive, specialized hardware. This book assumes that you have a good amount of Cisco networking knowledge, and it will focus more on Packet Tracer rather than networking.

  4. Joint DOE/NRC field study of tracer migration in the unsaturated zone

    International Nuclear Information System (INIS)

    Nyhan, J.; Polzer, W.; Essington, E.; Cokal, E.; Lane, L.; Lopez, E.; Stallings, E.; Walker, R.

    1986-03-01

    The results of a joint DOE/NRC field experiment to evaluate leaching and transport of solutes in a sandy silt backfill used for shallow land burial operations at Los Alamos are presented for steady-state and unsteady-state flow conditions. The migration of iodide, bromide, and lithium through the backfill material is studied as functions of depth and time and they are compared with one another. The bromide and iodide tracer data are used to estimate the diffusion coefficient, the tortuosity factor, and dispersivity. These values are used to calculate effective dispersion coefficients for subsequent analyses of the retardation factor and the distribution coefficient for lithium using least squares procedures. The results of the tracer migration study are discussed relative to challenges facing the waste management community, and chemical transport modeling opportunities are presented for a modeling workshop to be held in FY86

  5. Close relationship between fMRI signals and transient heart rate changes accompanying K-complex. Simultaneous EEG/fMRI study

    International Nuclear Information System (INIS)

    Kan, Shigeyuki; Koike, Takahiko; Miyauchi, Satoru; Misaki, Masaya

    2009-01-01

    Combining functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) allows the investigation of spontaneous activities in the human brain. Recently, by using this technique, increases in fMRI signal accompanying transient EEG activities such as sleep spindles and slow waves were reported. Although these fMRI signal increases appear to arise as a result of the neural activities being reflected in the EEG, when the influence of physiological activities upon fMRI signals are taken into consideration, it is highly controversial that fMRI signal increases accompanying transient EEG activities reflect actual neural activities. In the present study, we conducted simultaneous fMRI and polysomnograph recording of 18 normal adults, to study the effect of transient heart rate changes after a K-complex on fMRI signals. Significant fMRI signal increase was observed in the cerebellum, the ventral thalamus, the dorsal part of the brainstem, the periventricular white matter and the ventricle (quadrigeminal cistern). On the other hand, significant fMRI signal decrease was observed only in the right insula. Moreover, intensities of fMRI signal increase that was accompanied by a K-complex correlated positively with the magnitude of heart rate changes after a K-complex. Previous studies have reported that K-complex is closely related with sympathetic nervous activity and that the attributes of perfusion regulation in the brain differ during wakefulness and sleep. By taking these findings into consideration, our present results indicate that a close relationship exists between a K-complex and the changes in cardio- and neurovascular regulations that are mediated by the autonomic nervous system during sleep; further, these results indicate that transient heart rate changes after a K-complex can affect the fMRI signal generated in certain brain regions. (author)

  6. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    Science.gov (United States)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    Groundwater dating tracers are an essential tool for analyzing hydrologic conditions in groundwater systems. Commonly used tracers for dating post-1940's groundwater include sulfur hexafluoride (SF6), chlorofluorocarbons (CFCs), 3H-3He, and other isotopic tracers (85Kr, δ2H and δ18O isotopes, etc.). Each tracer carries a corresponding set of advantages and limitations imposed by field, analytical, and interpretive methods. Increasing the number available tracers is appealing, particularly if they possess inert chemical properties and unique temporal emission histories from other tracers. Atmospherically derived halogenated trace gases continue to hold untapped potential for new tracers, as they are generally inert and their emission histories are well documented. SF5CF3, and CFC-13 were previously shown to have application as dating tracers, though their low mixing ratios and low solubility require large amounts of water to be degassed for their quantification. Two related groups of compounds, hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) are hypothesized to be potential age tracers, having similar mixing ratios to the CFCs and relatively high solubility. However, these compounds yield gas chromatography electron capture detector (GC-ECD) responses that are 10-2 -10-5 less than CFC-12, making purge and trap or field stripping GC-ECD approaches impractical. Therefore, in order to use dissolved HCFCs and HFCs as age tracers, different approaches are needed. To solve this problem, we developed an analytical method that uses an atomic emission detector (GC-AED) in place of an ECD to detect fluorinated compounds. In contrast to the ECD, the AED is a universally sensitive, highly linear, elementally specific detector. The new GC-AED system is being used to measure chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a), and other fluorinated compounds in one liter water samples to study their potential as age dating tracers. HCFC-22 is a

  7. Proceedings of the atmospheric tracers and tracer application workshop

    International Nuclear Information System (INIS)

    Barr, S.; Gedayloo, T.

    1979-12-01

    In addition to presentations by participating members a general discussion was held in order to summarize and outline the goals and objectives of the workshop. A number of new low level background tracers such as heavy methanes, perfluorocarbons, multiply labeled isotopes such as 13 C 18 O 2 , helium 3, in addition to sample collection techniques and analytical methods for various tracers were discussed. This report is a summary of discussions and papers presented at this workshop

  8. Tracer dispersion in planar multipole flows

    International Nuclear Information System (INIS)

    Koplik, J.; Redner, S.; Hinch, E.J.

    1994-01-01

    We study the motion of passive Brownian tracer particles in steady two-dimensional potential flows between sources and sinks. Our primary focus is understanding the long-time properties of the transit time probability distribution for the tracer to reach the sink p(t) and the influence of the flow geometry on this probability. A variety of illustrative case studies is considered. For radial potential flow in an annular region, competition between convection and diffusion leads to nonuniversal decay of the transit time probability. Dipolar and higher multipole flows are found to exhibit generic features, such as a power-law decay in p(t) with an exponent determined by the multipole moment, an exponential cutoff related to stagnation points, and a ''shoulder'' in p(t) that is related to reflection from the system boundaries. For spatially extended sinks, it is also shown that the spatial distribution of the collected tracer is independent of the overall magnitude of the flow field and that p(t) decays as a power law with a geometry-dependent exponent. Our results may offer the possibility of using tracer measurements to characterize the flow geometry of porous media

  9. Use of radioactive tracers in dynamic sedimentology

    International Nuclear Information System (INIS)

    Tola, Francois.

    1982-01-01

    In the first part, developments in the use of radioactive tracers in sedimentology are recalled together with the corresponding fields of application and the identities of the main users. The state-of-the-art in France is also discussed; The main characteristics of the method are then described and compared with those of more classical methods. The results that can be obtained with tracer methods are then outlined. The criteria employed to establish the granulometry characteristics of the tracer, the particular radioisotope to be used, and the masses and activities involved, are treated. A list is then given of the main isotopes available in France and their characteristics. The various different labelling techniques employed are studied together with their respective advantages and disadvantages. The special case of pelitic sediments is mentioned. The use of reduced model isotope generators, double labelling and applications to studies of the mud plug in the Gironde Estuary are also discussed. The methods and materials used for injecting and detecting tracers are described, emphasis being given to the economic factors associated with the use of radioactive tracers in sedimentology. The second part of the report contains two chapters: - studies of transport by driftage: presentation and analysis of results and the application of the Count Rate Balance method to obtain quantitative information on transport; - studies of in-suspension transport of fine sediments in the sea: the procedures adopted from the moment when the tracer is introduced up to the time when the results are analyzed and interpreted, enables the trajectories and mean velocities of the transported sediments to be determined together with their degree of dilution and their settling speeds and rates; it is also possible to investigate the evolution and horizontal dispersion of the sediments in this way. Results from recent experiments are presented in both parts of the report

  10. Use of artificial tracers in hydrology

    International Nuclear Information System (INIS)

    1991-05-01

    The IAEA has convened an Advisory Group Meeting with the following objectives: To define the role of artificial radioactive tracers for water tracing in comparison with other non-radioactive tracers. To evaluate the real needs of artificial radioactive tracers in hydrology. To identify the fields for which artificial radioactive tracers are useful as well as those in which they can be substituted by other tracers. To discuss the strategy to be adopted to overcome the difficulties derived from the restrictions on the use of radioactive tracers in hydrology. The meeting was held at IAEA Headquarters from 19 to 22 March 1990, and was attended by 30 participants from 15 Member States. The conclusions and recommendations are that the use of artificial radioactive tracers should be restricted to cases where other tracers cannot be used or do not provide the same quality of information. Tritium, iodine-131, bromine-82, chromium-51 in the form of Cr-EDTA, technetium-99m obtained from 99 Mo-generators and gold-198 as an adsorbable tracer are, practically, the only radionuclides used for water tracing. The use of other radionuclides for this purpose does not appear to be necessary, possible and/or convenient. Refs, figs and tabs

  11. A Comparative Uptake Study of Multiplexed PET Tracers in Mice with Turpentine-Induced Inflammation

    Directory of Open Access Journals (Sweden)

    Tingting Huang

    2012-11-01

    Full Text Available The potential value of multiplexed positron emission tomography (PET tracers in mice with turpentine-induced inflammation was evaluated and compared with 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG for glucose metabolism imaging. These PET tracers included [18F]fluoromethylcholine ([18F]FCH for choline metabolism imaging, (S-[11C]methyl-D-cysteine ([11C]DMCYS for amino acid metabolism imaging, [11C]bis(zinc(II-dipicolylamine ([11C]DPA-Zn2+ for apoptosis imaging, 2-(4-N-[11C]-methylaminophenyl-6-hydroxybenzothiazole ([11C]PIB for β amyloid binding imaging, and [18F]fluoride (18F− for bone metabolism imaging. In mice with turpentine-induced inflammation mice, the biodistribution of all the tracers mentioned above at 5, 15, 30, 45, and 60 min postinjection was determined. Also, the time-course curves of the tracer uptake ratios for inflammatory thigh muscle (IM to normal uninflammatory thigh muscle (NM, IM to blood (BL, IM to brain (BR, and IM to liver (LI were acquired, respectively. Moreover, PET imaging with the tracers within 60 min postinjection on a clinical PET/CT scanner was also conducted. [18F]FDG and 18F− showed relatively higher uptake ratios for IM to NM, IM to BL, IM to BR, and IM to LI than [18F]FCH, [11C]DPA-Zn2+, [11C]DMCYS and [11C]PIB, which were highly consistent with the results delineated in PET images. The results demonstrate that 18F− seems to be a potential PET tracer for inflammation imaging. [18F]FCH and [11C]DMCYS, with lower accumulation in inflammatory tissue than [18F]FDG, are not good PET tracers for inflammation imaging. As a promising inflammatory tracer, the chemical structure of [11C]DPA-Zn2+ needs to be further optimized.

  12. MRI case studies

    International Nuclear Information System (INIS)

    Huggett, S.; Barber, J.

    1989-01-01

    Three case studies are presented to show the value of magnetic resonance imaging used in conjunction with other imaging techniques. In each case MRI proved a vital diagnostic tool and superior to CT in showing firstly the haematoma in a patient with aphasia and right-sided weakness, secondly the size of the disc herniation in a patient with severe leg and ankle pains and thirdly the existence of a metastatic lesion in a patient with a previous history of breast cancer. 11 figs

  13. Tracer migration experiments in the Stripa mine 1980-1991

    International Nuclear Information System (INIS)

    Birgersson, L.; Widen, H.; Aagren, T.; Neretnieks, I.

    1992-05-01

    During more than 10 years, tracer experiments have been performed in the Stripa mine as part of the Stripa project to investigate the properties of both 'average' fractured rock and fracture zones. Experiments have been performed that have ranged from a few decimeters, to examine the diffusion into the rock matrix, up to tracer migration to a drift more than 50 meters from the injection point. This report compiles the results and experience that have been gained from all these tracer experiments. The experiments that are described in this report are: * The in-situ diffusion experiment where simultaneous flow and diffusion of tracers in undisturbed rock were studied over more than 3 years to validate diffusivities obtained under laboratory conditions. * Migration in a single fracture where water flow distribution and tracer transport were studied using both conservative and sorbing tracers over migration distances up to 10 meters. * The 3-D migration experiment where water inflow and tracer transport to a drift covered with 350 plastic sheet were investigated to get information on flow porosity, dispersion and channeling. The transport distances were between 10 and 56 meters from the injection points to the drift. * The channeling experiments in which the aim was to examine the channeling properties of single fractures in detail. Pressure pulse tests and tracer experiments were performed over a distances of 2 meters. * The tracer migration experiment in the validation drift where the tracer were injected mainly in a fracture zone and the collection was inside both a drift covered with plastic sheets similar to in the 3-D experiment as well as in a borehole. The distances between injection and sampling location were between 10 and 25 meters. (57 refs.) (au)

  14. A Preliminary Study on the Measurement of Sediment Concentration in Hill-Slope Runoff with an Electrolyte Tracer

    Directory of Open Access Journals (Sweden)

    Xiaonan Shi Fan Zhang

    2012-01-01

    Full Text Available Sediment concentration in hill-slope runoff is an important index for soil erosion. Developing a reliable and portable measuring system of sediment concentration is a core issue for soil and water conservation study, especially for the Tibetan Plateau under unfavorable climate and terrain conditions for field investigation. Challenges include uneven distribution of sediment across a runoff section as well as difficulty in detecting a wide range of particle sizes. An electrolyte tracer, with the advantage of uniform distribution and its widely used electric-conductivity sensor, can avoid the problems of direct measurement of sediment. A new measurement method of sediment concentration in runoff with an electrolyte tracer is proposed based on a premise that sediment concentration is closely correlated with hydrodynamic dispersion coefficient of solute in runoff. In this study, an experiment system of hill-slope runoff with an electrolyte tracer and sediments is first designed. Second, two model parameters in the advective-dispersive equation of solute transport, flow velocity and diffusion coefficient, are inversely estimated by calibrating the observed concentrations of an electrolyte tracer. And third, the relationship between sediment concentrations and hydrodynamic dispersion coefficients are defined through specified regression. As a result, a measurement system of sediment concentration in hill-slope runoff with an electrolyte tracer is primarily established by integrating the relationship of variables, experiment system, and model theory.

  15. Isotopic and geochemical tracers for fingerprinting process-affected waters in the oil sands industry: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, J.J.; Birks, S.J.; Moncur, M.; Yi, Y.; Tattrie, K.; Jasechko, S.; Richardson, K.; Eby, P. [Alberta Innovates - Technology Futures (Canada)

    2011-04-15

    During 2009 and 2010, Alberta Innovates - Technology Futures carried out a pilot study for Alberta Environment to examine the possibility of labeling process affected water from oil sands operations with isotropic and geochemical tracers. For the study, 3 oil sands operators furnished logistical support and personnel, 39 samples were gathered and several isotope tracers were measured. In addition, geotechnical analyses were performed and the presence of organic compounds in the samples was scanned using Fourier transform ion cyclotron resonance mass spectrometry. Results showed that the selected tracers were able to label water sources in some locations, however they cannot be used as a universal method and a case by case approach needs to be adopted. This study pointed out that Fourier transform ion cyclotron resonance mass spectrometry is the best way to construct a dataset for use in identification of process affected waters.

  16. Simulation and interpretation of inter-well tracer tests

    Directory of Open Access Journals (Sweden)

    Dugstad Øyvind

    2013-05-01

    Full Text Available In inter-well tracer tests (IWTT, chemical compounds or radioactive isotopes are used to label injection water and gas to establish well connections and fluid patterns in petroleum reservoirs. Tracer simulation is an invaluable tool to ease the interpretation of IWTT results and is also required for assisted history matching application of tracer data. In this paper we present a new simulation technique to analyse and interpret tracer results. Laboratory results are used to establish and test formulations of the tracer conservation equations, and the technique is used to provide simulated tracer responses that are compared with observed tracer data from an extensive tracer program. The implemented tracer simulation methodology use a fast post-processing of previously simulated reservoir simulation runs. This provides a fast, flexible and powerful method for analysing gas tracer behaviour in reservoirs. We show that simulation time for tracers can be reduced by factor 100 compared to solving the tracer flow equations simultaneously with the reservoir fluid flow equations. The post-processing technique, combined with a flexible built-in local tracer-grid refinement is exploited to reduce numerical smearing, particularly severe for narrow tracer pulses.

  17. Tracer Equivalent Latitude: A Diagnostic Tool for Isentropic Transport Studies.

    Science.gov (United States)

    Allen, Douglas R.; Nakamura, Noboru

    2003-01-01

    Area equivalent latitude based on potential vorticity (PV) is a widely used diagnostic for isentropic transport in the stratosphere and upper troposphere. Here, an alternate method for calculating equivalent latitude is explored, namely, a numerical synthesis of a PV-like tracer from a long-term integration of the advection-diffusion equation on isentropic surfaces. It is found that the tracer equivalent latitude (TrEL) behaves much like the traditional PV equivalent latitude (PVEL) despite the simplified governing physics; this is evidenced by examining the kinematics of the Arctic lower stratospheric vortex. Yet in some cases TrEL performs markedly better as a coordinate for long-lived trace species such as ozone. These instances include analysis of lower stratospheric ozone during the Stratospheric Aerosol and Gas Experiment (SAGE) III Ozone Loss and Validation Experiment (SOLVE) campaign and three-dimensional reconstruction of total column ozone during November-December 1999 from fitted ozone-equivalent latitude relationship. It is argued that the improvement is due to the tracer being free from the diagnostic errors and certain diabatic processes that affect PV. The sensitivity of TrEL to spatial and temporal resolution, advection scheme, and driving winds is also examined.

  18. 18F-DOPA PET/CT and MRI Findings in a Patient With Multiple Meningiomas.

    Science.gov (United States)

    Calabria, Ferdinando F; Chiaravalloti, Agostino; Calabria, Eros N; Grillea, Giovanni; Schillaci, Orazio

    2016-08-01

    A 56-year-old man was referred to our Department for a 2-year story of upper limb tremor, severe headache, and episodes of confusion. Brain F-DOPA PET/CT showed multiple areas of tracer uptake in the two hemispheres of the brain. Subsequent MRI displayed demyelinating foci with high contrast enhancement. Histological specimen confirmed the diagnosis of multiple meningiomas.

  19. Xanthine tracers and their preparation

    International Nuclear Information System (INIS)

    Groman, E.V.; Cabelli, M.D.

    1980-01-01

    Compounds useful as tracers in the radioimmunoassay of xanthine derivatives such as theophylline and pharmacologically related drugs are described. They are substituted xanthines in which at least one substituted radical contains radioiodine. The tracers are made by linking radioiodinatable or preradioiodinated radicals to the xanthine derivative which is to be assayed. The tracers may be employed in known radioimmunoassay techniques. (author)

  20. Demonstration of metabolic and cellular effects of portal vein ligation using multi-modal PET/MRI measurements in healthy rat liver.

    Directory of Open Access Journals (Sweden)

    András Fülöp

    Full Text Available OBJECTIVES: In the early recognition of portal vein ligation (PVL induced tumor progression, positron emission tomography and magnetic resonance imaging (PET/MRI could improve diagnostic accuracy of conventionally used methods. It is unknown how PVL affects metabolic patterns of tumor free hepatic tissues. The aim of this preliminary study is to evaluate the effect of PVL on glucose metabolism, using PET/MRI imaging in healthy rat liver. MATERIALS AND METHODS: Male Wistar rats (n=30 underwent PVL. 2-deoxy-2-(18Ffluoro-D-glucose (FDG PET/MRI imaging (nanoScan PET/MRI and morphological/histological examination were performed before (Day 0 and 1, 2, 3, and 7 days after PVL. Dynamic PET data were collected and the standardized uptake values (SUV for ligated and non-ligated liver lobes were calculated in relation to cardiac left ventricle (SUVVOI/SUVCLV and mean liver SUV (SUVVOI/SUVLiver. RESULTS: PVL induced atrophy of ligated lobes, while non-ligated liver tissue showed compensatory hypertrophy. Dynamic PET scan revealed altered FDG kinetics in both ligated and non-ligated liver lobes. SUVVOI/SUVCLV significantly increased in both groups of lobes, with a maximal value at the 2nd postoperative day and returned near to the baseline 7 days after the ligation. After PVL, ligated liver lobes showed significantly higher tracer uptake compared to the non-ligated lobes (significantly higher SUVVOI/SUVLiver values were observed at postoperative day 1, 2 and 3. The homogenous tracer biodistribution observed before PVL reappeared by 7th postoperative day. CONCLUSION: The observed alterations in FDG uptake dynamics should be taken into account during the assessment of PET data until the PVL induced atrophic and regenerative processes are completed.

  1. Radiological safety methodology in radioactive tracer applications for hydrodynamics and environmental studies

    International Nuclear Information System (INIS)

    Suarez, R.; Badano, A.; Dellepere, A.; Artucio, G.; Bertolotti, A.

    1995-01-01

    The use of radioactive tracer techniques as control sewage disposal contamination in Montevideo Estuarine and Carrasco beach has been studied for the Nuclear Technology National Direction. Hydrodynamic models simulation has been introduced as work methodology. As well as radiological safety and radioactive material applications in the environmental studies has been evaluated mainly in the conclusions and recommendations in this report. maps

  2. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  3. Experimental design for estimating parameters of rate-limited mass transfer: Analysis of stream tracer studies

    Science.gov (United States)

    Wagner, Brian J.; Harvey, Judson W.

    1997-01-01

    Tracer experiments are valuable tools for analyzing the transport characteristics of streams and their interactions with shallow groundwater. The focus of this work is the design of tracer studies in high-gradient stream systems subject to advection, dispersion, groundwater inflow, and exchange between the active channel and zones in surface or subsurface water where flow is stagnant or slow moving. We present a methodology for (1) evaluating and comparing alternative stream tracer experiment designs and (2) identifying those combinations of stream transport properties that pose limitations to parameter estimation and therefore a challenge to tracer test design. The methodology uses the concept of global parameter uncertainty analysis, which couples solute transport simulation with parameter uncertainty analysis in a Monte Carlo framework. Two general conclusions resulted from this work. First, the solute injection and sampling strategy has an important effect on the reliability of transport parameter estimates. We found that constant injection with sampling through concentration rise, plateau, and fall provided considerably more reliable parameter estimates than a pulse injection across the spectrum of transport scenarios likely encountered in high-gradient streams. Second, for a given tracer test design, the uncertainties in mass transfer and storage-zone parameter estimates are strongly dependent on the experimental Damkohler number, DaI, which is a dimensionless combination of the rates of exchange between the stream and storage zones, the stream-water velocity, and the stream reach length of the experiment. Parameter uncertainties are lowest at DaI values on the order of 1.0. When DaI values are much less than 1.0 (owing to high velocity, long exchange timescale, and/or short reach length), parameter uncertainties are high because only a small amount of tracer interacts with storage zones in the reach. For the opposite conditions (DaI ≫ 1.0), solute

  4. Early studies of instant-fMRI for routine examination

    International Nuclear Information System (INIS)

    Sakurai, Yuuki; Harada, Kuniaki; Nagahama, Hiroshi; Akatsuka, Yoshihiro; Shinozaki, Jun

    2010-01-01

    Authors are developing a low-burden, short-time acquisition method of functional magnetic resonance imaging (fMRI) with 3T machine, named ''Instant-fMRI'', aiming for its application to routine examinations, of which results of early studies on identification of the language hemisphere are reported. Subjects were 10 healthy volunteers (8 males, 2 females, mean age 34.2 y, 8 right-handers) and 5 right-hander patients with brain tumor (4 males, 1 female, mean age 50 y). The machine was GE Signa HDx 3.0T ver. 14, using 8 channel head coil. For Instant-fMRI, T1-weighted imaging sequence for mapping was in fast spoiled gradient recalled acquisition in the steady state (fSPGR) mode (scan time: 1 min 44 sec) and fMRI sequence, in GRE-EPI (scan time: 1 min), which thus required only about 3 min in total. Reference was defined to be the anterior-posterior commissure line, to which parallel sections involving centriciput and cerebellum were acquired. Rest (30 sec)-task (shiritori language game, 30 sec) cycle was to be one in instant-fMRI in contrast to three in the conventional fMRI. Volunteers received both instant-fMRI and conventional fMRI and patients, the former alone. Data were analyzed by GE Brain Wave PA. Right and left hemisphere of the left and right hander, respectively, was identified to be activated by instant-fMRI in 9 of 10 volunteers and in all patients, and by the conventional fMRI, in all volunteers. The instant-fMRI can be a useful examination of other brain functions as well as identifying the language field when acquisition parameters for desired diagnostic purpose are optimized. (T.T.)

  5. The use of Na-22 as a tracer for long-term bone mineral turnover studies

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Palmer, R.F.; Gillis, M.F.

    1979-01-01

    Sodium-22 has been studied as a tracer for bone mineral metabolism in rats and dogs. When incorporated into bone during growth from birth to adulthood, the bone becomes uniformly tagged with Na-22, which is released through the metabolic turnover of the bone. The Na-22 not incorporated in the bone matrix is rapidly excreted within a few days when animals are fed high, but nontoxic levels of NaCl. The Na-22 tracer can be used to measure bone mineral loss in animals during space flight and in research on bone disease

  6. Recent progress of {sup 10}Be tracer studies in Chinese loess

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Weijian, E-mail: weijian@loess.llqg.ac.cn [State Key Laboratory of Loess and Quaternary Geology, Institute of Earth Environment, Chinese Academy of Sciences, Xi’an 710061 (China); Shaanxi Provincial Key Laboratory of Accelerator Mass Spectrometry and Application, Xi’an AMS Center, Xi' an 710061 (China); Joint Center for Global Change Studies, Beijing 100875 (China); Xie, Xingjun [State Key Laboratory of Loess and Quaternary Geology, Institute of Earth Environment, Chinese Academy of Sciences, Xi’an 710061 (China); Shaanxi Provincial Key Laboratory of Accelerator Mass Spectrometry and Application, Xi’an AMS Center, Xi' an 710061 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Beck, Warren [NSF-Arizona AMS Facility, University of Arizona, Tucson, AZ 85721 (United States); Kong, Xianghui; Xian, Feng; Du, Yajuan; Wu, Zhenkun [State Key Laboratory of Loess and Quaternary Geology, Institute of Earth Environment, Chinese Academy of Sciences, Xi’an 710061 (China); Shaanxi Provincial Key Laboratory of Accelerator Mass Spectrometry and Application, Xi’an AMS Center, Xi' an 710061 (China)

    2015-10-15

    Studies of cosmogenic {sup 10}Be in Chinese loess began about twenty-five years ago and since then a number of research groups worldwide have contributed to a firm understanding of the production, transport, deposition and storage of {sup 10}Be in loess. The essential characteristics that make {sup 10}Be a useful isotopic tracer in loess, include: (1) dominant atmospheric production directly linked to the intensity of the Earth’s magnetic field; (2) climate-dependent deposition; and (3) subsequent immobility, so that as {sup 10}Be accumulates in a loess profile its stratigraphic integrity is preserved. This fact, combined with very high deposition rates in loess on the Chinese Loess Plateau, makes {sup 10}Be an especially valuable continental archive of paleoclimate and paleomagnetism, complementing marine and ice-core records. Here we provide in particular the most recent progress of {sup 10}Be tracer studies in Chinese loess, including the determination of the correct age of the Brunhes–Matuyama polarity reversal at 780 ± 3 ka B.P., in accord with marine and ice records, and quantitative reconstruction of 130-ka paleoprecipitation using {sup 10}Be from Chinese loess profiles.

  7. Tritium and deuterium as water tracers in hydrologic systems. Completion report

    International Nuclear Information System (INIS)

    Stewart, G.L.; Stetson, J.R.

    1975-05-01

    A study was conducted to evaluate the suitability of deuterium and tritium as tracers to depict water and pollutant movement in porous media. This involved studying the interaction of these tracers with soil materials and evaluating this interaction in terms of retardation in tracer flow velocity, compared to bulk water flow. Previous work had suggested that tritium and deuterium interact with soils and are removed from tracer solution during flow. The data presented clearly show that a tracing front becomes diluted in tracer during infiltration into oven-dried soil. There appears to be very little difference between the degree of tritium and deuterium interaction. The source of interaction is demonstrated to be primarily hydroxyl associated with the clay minerals. These exchange sites are destroyed by heating soil to 70C which eliminates tracer loss during infiltration

  8. Tracer techniques in food industry

    International Nuclear Information System (INIS)

    Pertsovskij, E.S.; Sakharov, Eh.V.; Dolinin, V.A.

    1980-01-01

    The appicability of radioactive tracer techniques to process control in food industry are considered. Investigations in the field of food industry carried out using the above method are classified. The 1 class included investigations with preliminary preparation of a radioactive indicator and its following introduction in the system studied. The 2 class includes investigations based on the introduction in the system studied of a non-active indicator which is activated in a neutron flux being in samples selected in or after the process investigated. The 3 class includes studies based on investigations of natural radioactivity of certain nuclides in food stuff. The application of tracer techniques to the above classes of investigations in various fields of food industry and the equipment applied are considered in detail [ru

  9. Application of isotope tracer technique on the study of the filling and release behavior of carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Shengwei; Guo Jinxue; Li Yan; Li Yulan; Li Wenxin; Liu Shiyuan

    2004-01-01

    The behaviors of washing and release of 110 Ag m -AgNO 3 from carbon nanotubes (CNTs), following soak of opened CNTs in 110 Ag m -AgNO 3 solutions are investigated with the isotope tracer technique. The filled CNTs samples are characterized by HREM, SEM, XRD and EDS. The amount of filled materials is also estimated by the isotope tracer technique. It shows that there are silver materials filled in the CNTs and would not release from the cavities. The results indicate that radioactive tracer is an effective and powerful technique to be applied into study of filling and release behaviors of CNTs as well as estimating the amount of filled materials. (authors)

  10. A polymer-based magnetic resonance tracer for visualization of solid tumors by 13C spectroscopic imaging.

    Directory of Open Access Journals (Sweden)

    Yoshikazu Suzuki

    Full Text Available Morphological imaging precedes lesion-specific visualization in magnetic resonance imaging (MRI because of the superior ability of this technique to depict tissue morphology with excellent spatial and temporal resolutions. To achieve lesion-specific visualization of tumors by MRI, we investigated the availability of a novel polymer-based tracer. Although the 13C nucleus is a candidate for a detection nucleus because of its low background signal in the body, the low magnetic resonance sensitivity of the nucleus needs to be resolved before developing a 13C-based tracer. In order to overcome this problem, we enriched polyethylene glycol (PEG, a biocompatible polymer, with 13C atoms. 13C-PEG40,000 (13C-PEG with an average molecular weight of 40 kDa emitted a single 13C signal with a high signal-to-noise ratio due to its ability to maintain signal sharpness, as was confirmed by in vivo investigation, and displayed a chemical shift sufficiently distinct from that of endogenous fat. 13C-PEG40,000 intravenously injected into mice showed long retention in circulation, leading to its effective accumulation in tumors reflecting the well-known phenomenon that macromolecules accumulate in tumors because of leaky tumor capillaries. These properties of 13C-PEG40,000 allowed visualization of tumors in mice by 13C spectroscopic imaging. These findings suggest that a technique based on 13C-PEG is a promising strategy for tumor detection.

  11. An fMRI study of Agency

    DEFF Research Database (Denmark)

    Charalampaki, Angeliki

    2017-01-01

    Motor area has a distinct directionality, depending on the stage of the volitional movement. In this study, we were interested in assessing the neuronal mechanism underlying this phenomenon. We therefore performed an fMRI study of Agency, to exploit the high spatial resolution this imaging technique...... displays. For the purposes of our study twenty participants were recruited. The experimental procedure we considered appropriate to study the Sense of Agency, involved participants laying inside the fMRI scanner and while they had no visual feedback of their hand, they were instructed to draw straight...... lines on a tablet with a digital pen. They could only see the consequences of their movement as a cursor’s movement on a screen. After finishing their movement, participants were requested to make a judgment over whether they felt they were the Agent of the observed movement or not. The analysis of our...

  12. Arterial Spin Labeling (ASL) fMRI: advantages, theoretical constrains, and experimental challenges in neurosciences.

    Science.gov (United States)

    Borogovac, Ajna; Asllani, Iris

    2012-01-01

    Cerebral blood flow (CBF) is a well-established correlate of brain function and therefore an essential parameter for studying the brain at both normal and diseased states. Arterial spin labeling (ASL) is a noninvasive fMRI technique that uses arterial water as an endogenous tracer to measure CBF. ASL provides reliable absolute quantification of CBF with higher spatial and temporal resolution than other techniques. And yet, the routine application of ASL has been somewhat limited. In this review, we start by highlighting theoretical complexities and technical challenges of ASL fMRI for basic and clinical research. While underscoring the main advantages of ASL versus other techniques such as BOLD, we also expound on inherent challenges and confounds in ASL perfusion imaging. In closing, we expound on several exciting developments in the field that we believe will make ASL reach its full potential in neuroscience research.

  13. Nuclear medicine and imaging research (quantitative studies in radiopharmaceutical science). Progress report, January 1, 1992--December 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, M.; Beck, R.N.

    1992-06-01

    This report describes three studies aimed at using radiolabeled pharmaceuticals to explore brain function and anatomy. The first section describes the chemical preparation of [F18]fluorinated benzamides (dopamine D-2 receptor tracers), [F18]fluorinated benzazepines (dopamine D-1 receptor tracers), and tissue distribution of [F18]-fluoxetine (serotonin reuptake site tracer). The second section relates pharmacological and behavioral studies of amphetamines. The third section reports on progress made with processing of brain images from CT, MRI and PET/SPECT with regards to brain metabolism of glucose during mental tasks.

  14. Oxygen tracer studies of ferroelectric fatigue in Pb(Zr,Ti)O3 thin films

    International Nuclear Information System (INIS)

    Schloss, Lawrence F.; McIntyre, Paul C.; Hendrix, Bryan C.; Bilodeau, Steven M.; Roeder, Jeffrey F.; Gilbert, Stephen R.

    2002-01-01

    Long-range oxygen motion has been observed in Pt/Pb(Zr,Ti)O 3 /Ir thin-film structures after electrical fatigue cycling at room temperature. Through an exchange anneal, isotopic 18 O was incorporated as a tracer into bare Pb(Zr,Ti)O 3 (PZT) films, allowing secondary ion mass spectrometry measurements of the tracer profile evolution as a function of the number of polarization reversals. Observation of 18 O tracer redistribution during voltage cycling, which is presumably mediated by oxygen vacancy motion, was found to be strongly dependent upon the thermal history of the film. However, there was no strong correlation between the extent of 18 O tracer redistribution and the extent of polarization suppression induced by voltage cycling. Our results suggest that oxygen vacancy motion plays, at most, a secondary role in ferroelectric fatigue of PZT thin films

  15. Study of MRI in stratified viscous plasma configuration

    Science.gov (United States)

    Carlevaro, Nakia; Montani, Giovanni; Renzi, Fabrizio

    2017-02-01

    We analyze the morphology of the magneto-rotational instability (MRI) for a stratified viscous plasma disk configuration in differential rotation, taking into account the so-called corotation theorem for the background profile. In order to select the intrinsic Alfvénic nature of MRI, we deal with an incompressible plasma and we adopt a formulation of the local perturbation analysis based on the use of the magnetic flux function as a dynamical variable. Our study outlines, as consequence of the corotation condition, a marked asymmetry of the MRI with respect to the equatorial plane, particularly evident in a complete damping of the instability over a positive critical height on the equatorial plane. We also emphasize how such a feature is already present (although less pronounced) even in the ideal case, restoring a dependence of the MRI on the stratified morphology of the gravitational field.

  16. Tracer attenuation in groundwater

    Science.gov (United States)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  17. The use of amino acid PET and conventional MRI for monitoring of brain tumor therapy

    DEFF Research Database (Denmark)

    Galldiks, Norbert; Law, Ian; Pope, Whitney B

    2017-01-01

    Routine diagnostics and treatment monitoring of brain tumors is usually based on contrast-enhanced MRI. However, the capacity of conventional MRI to differentiate tumor tissue from posttherapeutic effects following neurosurgical resection, chemoradiation, alkylating chemotherapy, radiosurgery, and......),O-(2-[18F]fluoroethyl)-l-tyrosine (FET) and 3,4-dihydroxy-6-[18F]-fluoro-l-phenylalanine (FDOPA) and summarizes investigations regarding monitoring of brain tumor therapy......./or immunotherapy may be limited. Metabolic imaging using PET can provide relevant additional information on tumor metabolism, which allows for more accurate diagnostics especially in clinically equivocal situations. This review article focuses predominantly on the amino acid PET tracers11C-methyl-l-methionine (MET...

  18. Feasibility of perfluorocarbon tracers (PFTs) in atmospheric source-receptor experiments

    International Nuclear Information System (INIS)

    Dietz, R.N.; Senum, G.I.

    1984-03-01

    A brief description of the perfluorocarbon tracer (PFT) system, which includes the tracers and the release equipment, the air samplers and the analyzers, is presented along with details on the research needs to provide a viable system for MATEX-scenario experiments. The present family of 2 viable PFTs needs to be increased to 5 to 6. Given the present precision of the analysis system, a one year long tracer experiment consisting of 4 hour releases every 60 hours from 5 different sites would require nearly 150 metric tons of PFTs at a cost of $15,000,000. Shortcomings in the programmable sampler include the pump, the sampling sequence control flexibility, data storage and retrieval, and the lack of remote communication capability; sampler adsorbent studies are also needed. The analytical system, including the catalyst processing bed, the chromatography column resolution, and the linearity of the detector, is in need of significant improvement. A higher resolution analysis system could significantly reduce analysis time but, more importantly, reduce tracer requirements more than 10-fold, for a cost savings potential of more than $13,000,000. A model is presented to demonstrate the feasibility of tracer material balances. Assessment of earlier long-range tracer experiments indicates the need for possibly 400 ground sampling sites requiring $8 to $14 million worth of samplers for a one-year tracer experiment. As many as six aircraft would be needed to conduct airborne model validation and material balance studies for each tracer plume

  19. Local recurrence of prostate cancer after radical prostatectomy is at risk to be missed in {sup 68}Ga-PSMA-11-PET of PET/CT and PET/MRI: comparison with mpMRI integrated in simultaneous PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, Martin T. [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg (Germany); Radtke, Jan P. [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Afshar-Oromieh, Ali; Flechsig, Paul; Giesel, Frederik; Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Roethke, Matthias C.; Bonekamp, David; Schlemmer, Heinz-Peter [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Hadaschik, Boris A.; Hohenfellner, Markus [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Gleave, Martin [University of British Columbia, The Vancouver Prostate Centre, Vancouver (Canada); Kopka, Klaus; Eder, Matthias [Division of Radiopharmaceutical Chemistry, German Cancer Research Center, Heidelberg (Germany); Heusser, Thorsten; Kachelriess, Marc [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Wieczorek, Kathrin [University Hospital Heidelberg, Institute of Pathology, Heidelberg (Germany); Sachpekidis, Christos; Dimitrakopoulou-Strauss, A. [Clinical Cooperation Unit Nuclear Medicine, German Cancer Research Center, Heidelberg (Germany)

    2017-05-15

    The positron emission tomography (PET) tracer {sup 68}Ga-PSMA-11, targeting the prostate-specific membrane antigen (PSMA), is rapidly excreted into the urinary tract. This leads to significant radioactivity in the bladder, which may limit the PET-detection of local recurrence (LR) of prostate cancer (PC) after radical prostatectomy (RP), developing in close proximity to the bladder. Here, we analyze if there is additional value of multi-parametric magnetic resonance imaging (mpMRI) compared to the {sup 68}Ga-PSMA-11-PET-component of PET/CT or PET/MRI to detect LR. One hundred and nineteen patients with biochemical recurrence after prior RP underwent both hybrid {sup 68}Ga-PSMA-11-PET/CT{sub low-dose} (1 h p.i.) and -PET/MRI (2-3 h p.i.) including a mpMRI protocol of the prostatic bed. The comparison of both methods was restricted to the abdomen with focus on LR (McNemar). Bladder-LR distance and recurrence size were measured in axial T2w-TSE. A logistic regression was performed to determine the influence of these variables on detectability in {sup 68}Ga-PSMA-11-PET. Standardized-uptake-value (SUV{sub mean}) quantification of LR was performed. There were 93/119 patients that had at least one pathologic finding. In addition, 18/119 Patients (15.1%) were diagnosed with a LR in mpMRI of PET/MRI but only nine were PET-positive in PET/CT and PET/MRI. This mismatch was statistically significant (p = 0.004). Detection of LR using the PET-component was significantly influenced by proximity to the bladder (p = 0.028). The PET-pattern of LR-uptake was classified into three types (1): separated from bladder; (2): fuses with bladder, and (3): obliterated by bladder. The size of LRs did not affect PET-detectability (p = 0.84), mean size was 1.7 ± 0.69 cm long axis, 1.2 ± 0.46 cm short-axis. SUV{sub mean} in nine men was 8.7 ± 3.7 (PET/CT) and 7.0 ± 4.2 (PET/MRI) but could not be quantified in the remaining nine cases (obliterated by bladder). The present study demonstrates

  20. Local study of pollutants dispersion by a real time tracer method

    International Nuclear Information System (INIS)

    Faivre-Pierret, R.X.; Sestier-Carlin, R.; Berne, P.

    1992-01-01

    It is possible to use a Gaussian mathematical model of atmospheric dispersion for calculating atmospheric transfer coefficient (ATC) in long range model, but for proximity models, an experimental model using a tracer technic has to take in account ground effects and natural or artificial obstacles. SF 6 tracer method gives the true plume ground trace in real time. The measured ATC shows a larger ground trace, lower concentration in the axis, and a displacement of the maximum concentration with regard to wind axis in comparison with the calculated ATC. (A.B.). 14 refs., 4 figs., 1 tab

  1. Coefficients of tracer transfer through membranes. Pt. 7

    Energy Technology Data Exchange (ETDEWEB)

    Dorabialska, A; Hawlicka, E; Plonka, A [Politechnika Lodzka (Poland)

    1974-01-01

    The doubled value of the tracer transfer coefficient in the self-diffusion process is equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The fundamental phenomenological relation can be deduced for the coefficients of tracer transfer between two phases of electrolyte solutions spearated by a virtual boundary. Indeed, the doubled value of the tracer mobility in the self-diffusion experiment (no concentration gradient of the traced substance) is equal to the sum of the tracer mobilities in the diffusion (tracer movement along with the concentration gradient of the traced substance) and interfusion experiments (tracer movement against the concentration gradient of the traced substance). Thus the doubled value of the tracer transfer coefficient in the self-diffusion process should be equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The experimental verification of that fundamental relation is presented.

  2. The G-spot: an observational MRI pilot study.

    Science.gov (United States)

    Maratos, Y K; Gombergh, R; Cornier, E; Minart, J P; Amoretti, N; Mpotsaris, A

    2016-08-01

    To identify a G-spot complex (GSC) in vivo in MRI examinations at 1.5 Tesla field strength. Observational study. Single centre. Twenty-one consecutive patients (January-March 2014). Imaging analysis of routine imaging protocols for usual medical indications with and without concomitant opacification of the vaginal cavity with inert ultrasound gel. The gel distends the otherwise collapsed vaginal walls, allowing for an improved discrimination of anatomic features. The macroscopic and histological results recently derived from the dissections of fresh cadavers by Ostrzenski et al. were translated into imaging characteristics to be expected in the respective MRI sequences (e.g. T1- and T2-weighted) in search of an in vivo correlate of the GSC. Age, menopause status, medical indication and diagnosis were co-variables. To analyse primarily whether MRI imaging is able to depict a distinct morphological entity in vivo matching the GSC, based on anatomical descriptions published recently. The elaboration of an appropriate MRI-imaging protocol was a secondary aim. A total of 21 studies were obtained. A GSC was identified within the anterior vaginal wall in 13/21 patients (62%). In all, 10/21 (48%) had vaginal gel opacification. We identified a GSC in 10/10 patients (100%) with opacification in all three planes of the T2 images. This was only true for 3/11 cases (27%) without opacification. There is evidence for an in vivo morphological correlate to the postmortem anatomical findings of a GSC described by Ostrzenski et al.; its visibility in MRI imaging can be significantly improved with vaginal opacification by ultrasound gel. Identification of G-spot by MRI with vaginal gel-opacification in 13/21 patients. © 2016 Royal College of Obstetricians and Gynaecologists.

  3. Our experience of blood flow measurements using radioactive tracers

    International Nuclear Information System (INIS)

    Danet, Bernard.

    1974-01-01

    A critical study of blood flow measuring methods is proposed. After a review of the various diffusible and non-diffusible radioactive tracers and the corresponding detector systems, the principles which allow to measure blood flow from the data so obtained, are studied. There is a different principle of flow measurement for each type of tracer. The theory of flow measurement using non-diffusible tracers (human serum albumin labelled with 131 I or sup(99m)Tc, 113 In-labelled siderophiline) and its application to cardiac flow measurement are described first. Then the theory of flow measurement using diffusible tracers ( 133 Xe, 85 Kr) and its application to measurement of blood flow through tissues (muscles and kidney particularly) are described. A personal experience of this various flow measurements is reported. The results obtained, the difficulties encountered and the improvments proposed are developed [fr

  4. Using tracers to understand the hydrology of an abandoned underground coal mine

    International Nuclear Information System (INIS)

    Canty, G.A.; Everett, J.W.

    1998-01-01

    Flooded underground mines pose a difficult problem for remediation efforts requiring hydrologic information. Mine environments are hydraulically complicated due to sinuous travel paths and variable hydraulic gradients. For an acidic mine remediation project, conducted by the University of Oklahoma in conjunction with the Oklahoma Conservation Commission, a tracer study was undertaken to identify basic hydrologic properties of a flooded coal mine. The study was conducted to investigate the possibility of in-situ remediation of acidic mine water with the use of alkaline coal combustion by-products. Information on the rate of flow and ''connectiveness'' of injection wells with the discharge point was needed to develop a treatment strategy. Fluorescent dyes are not typically used in mine tracer studies because of the low pH values associated with certain mines and a tendency to adsorb ferric iron precipitates. However, Rhodamine WT was used in one tracer test because it can be detected at low concentrations. Due to poor recovery, a second tracer test was undertaken using a more conservative tracer-chloride. Each tracer produced similar travel time results. Findings from this study suggest that Rhodamine WT can be used under slightly acidic conditions, with mixed results. The more conservative tracer provided somewhat better results, but recovery was still poor. Use of these tracers has provided some valuable information with regard to mine hydrology, but additional questions have been raised

  5. Assessment of atherosclerotic plaque activity in patients with sleep apnea using hybrid positron emission tomography/magnetic resonance imaging (PET/MRI): a feasibility study.

    Science.gov (United States)

    Kundel, Vaishnavi; Trivieri, Maria Giovanna; Karakatsanis, Nicolas A; Robson, Phillip M; Mani, Venkatesh; Kizer, Jorge R; Kaplan, Robert; Fayad, Zahi; Shah, Neomi

    2018-03-05

    Evidence suggests that the inflammatory state of an atherosclerotic plaque is important in predicting future risk of plaque rupture. This study aims to investigate the feasibility of measuring plaque inflammation in patients with obstructive sleep apnea (OSA) utilizing advanced vascular imaging - hybrid positron-emission tomography/magnetic resonance imaging (PET/MRI) with fluorodeoxyglucose (FDG) tracer-before and after continuous positive airway pressure (CPAP). Patients with newly diagnosed moderate to severe OSA underwent baseline PET/MRI for assessment of vascular inflammation of the carotid arteries and thoracic aorta prior to initiation of CPAP. Those adherent to CPAP returned for repeat imaging after 3-6 months of CPAP use. Atherosclerotic plaque activity, as measured by arterial wall FDG uptake, was calculated using target-to-background ratios (TBR) before and after CPAP. Five patients were recruited as part of a focused project. Mean age was 52 years (80% male), and mean apnea-hypopnea index (AHI) was 33. Three patients were objectively adherent with CPAP. In the pre-CPAP phase, all patients had focal FDG uptake in the carotid arteries and aorta. After CPAP, there was an average reduction in TBR of 5.5% (TBR mean ) and 6.2% (TBR max ) in carotid and aortic plaque inflammation, similar in magnitude to the reduction observed with statin therapy alone in non-OSA patients (previously reported by others). We demonstrate the feasibility of using hybrid PET/MRI to assess atherosclerotic plaque inflammation in patients with OSA before and after CPAP. Use of the vascular PET/MRI platform in patients with OSA may provide better insight into the role of OSA and its treatment in reducing atherosclerotic inflammation.

  6. Cluster analysis of DCE-MRI data identifies regional tracer-kinetic changes after tumor treatment with high intensity focused ultrasound

    NARCIS (Netherlands)

    Jacobs, Igor; Hectors, Stefanie J. C. G.; Schabel, Matthias C.; Grüll, Holger; Strijkers, Gustav J.; Nicolay, Klaas

    2015-01-01

    Evaluation of high intensity focused ultrasound (HIFU) treatment with MRI is generally based on assessment of the non-perfused volume from contrast-enhanced T1-weighted images. However, the vascular status of tissue surrounding the non-perfused volume has not been extensively investigated with MRI.

  7. Long residence times - bad tracer tests?

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2015-04-01

    Tracer tests conducted at geothermal well doublets or triplets in the Upper Rhine Rift Valley [1] all face, with very few exceptions so far, one common issue: lack of conclusive tracer test results, or tracer signals still undetectable for longer than one or two years after tracer injection. While the reasons for this surely differ from site to site (Riehen, Landau, Insheim, Bruchsal, ...), its effects on how the usefulness of tracer tests is perceived by the non-tracer community are pretty much the same. The 'poor-signal' frustration keeps nourishing two major 'alternative' endeavours : (I) design and execute tracer tests in single-well injection-withdrawal (push-pull), 'instead of' inter-well flow-path tracing configurations; (II) use 'novel' tracer substances instead of the 'old' ones which have 'obviously failed'. Frustration experienced with most inter-well tracer tests in the Upper Rhine Rift Valley has also made them be regarded as 'maybe useful for EGS' ('enhanced', or 'engineered' geothermal systems, whose fluid RTD typically include a major share of values below one year), but 'no longer worthwhile a follow-up sampling' in natural, large-scale hydrothermal reservoirs. We illustrate some of these arguments with the ongoing Bruchsal case [2]. The inter-well tracer test conducted at Bruchsal was (and still is!) aimed at assessing inter-well connectivity, fluid residence times, and characterizing the reservoir structure [3]. Fluid samples taken at the geothermal production well after reaching a fluid turnover of about 700,000 m3 showed tracer concentrations in the range of 10-8 Minj per m3, in the liquid phase of each sample (Minj being the total quantity of tracer injected as a short pulse at the geothermal re-injection well). Tracer signals might actually be higher, owing to tracer amounts co-precipitated and/or adsorbed onto the solid phase whose accumulation in the samples was unavoidable (due to pressure relief and degassing during the very sampling

  8. Flow-rate measurement using radioactive tracers and transit time method

    International Nuclear Information System (INIS)

    Turtiainen, Heikki

    1986-08-01

    The transit time method is a flow measurement method based on tracer techniques. Measurement is done by injecting to the flow a pulse of tracer and measuring its transit time between two detection positions. From the transit time the mean flow velosity and - using the pipe cross section area - the volume flow rate can be calculated. When a radioisotope tracer is used the measurement can be done from outside the pipe and without disturbing the process (excluding the tracer injection). The use of the transit time method has been limited because of difficulties associated with handling and availability of radioactive tracers and lack of equipment suitable for routine use in industrial environments. The purpose of this study was to find out if these difficulties may be overcome by using a portable isotope generator as a tracer source and automating the measurement. In the study a test rig and measuring equipment based on the use of a ''1''3''7Cs/''1''3''7''''mBa isotope generator were constructed. They were used to study the accuracy and error sources of the method and to compare different algorithms to calculate the transit time. The usability of the method and the equipment in industrial environments were studied by carrying out over 20 flow measurements in paper and pulp mills. On the basis of the results of the study, a project for constructing a compact radiatracer flowmeter for industrial use has been started. The application range of this kind of meter is very large. The most obvious applications are in situ calibration of flowmeters, material and energy balance studies, process equipment analyses (e.g. pump efficiency analyses). At the moment tracer techniques are the only methods applicable to these measurements on-line and with sufficient accuracy

  9. Wairakei tracer tests 1983

    International Nuclear Information System (INIS)

    McCabe, W.J.; Barry, B.J.

    1984-05-01

    Tracer tests, with and without, hot water reinjection into WK213 showed returns of tracer iodine-131; in wells in both the Waiora Valley and the eastern end of the field. The effect of reinjection at a rate of 200 cu. m/h was to reduce the arrived time from 15 to 7 days. Increasing the rate of reinjection into WK62 from 30 cu. m/h to 200 cu. m/h seemed to increase the initial velocity of the tracer wave and the distance it moved. However, returns were recorded only in the adjacent wells WK61 and WK63 with a very small, and three days delayed, response in WK43

  10. Predictions of tracer transport in interwell tracer tests at the C-Hole complex. Yucca Mountain site characterization project report milestone 4077

    International Nuclear Information System (INIS)

    Reimus, P.W.

    1996-09-01

    This report presents predictions of tracer transport in interwell tracer tests that are to be conducted at the C-Hole complex at the Nevada Test Site on behalf of the Yucca Mountain Site Characterization Project. The predictions are used to make specific recommendations about the manner in which the tracer test should be conducted to best satisfy the needs of the Project. The objective of he tracer tests is to study flow and species transport under saturated conditions in the fractured tuffs near Yucca Mountain, Nevada, the site of a potential high-level nuclear waste repository. The potential repository will be located in the unsaturated zone within Yucca Mountain. The saturated zone beneath and around the mountain represents the final barrier to transport to the accessible environment that radionuclides will encounter if they breach the engineered barriers within the repository and the barriers to flow and transport provided by the unsaturated zone. Background information on the C-Holes is provided in Section 1.1, and the planned tracer testing program is discussed in Section 1.2

  11. A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study

    International Nuclear Information System (INIS)

    Im, Chang-Hwan; Lee, Soo Yeol

    2006-01-01

    fMRI-constrained EEG/MEG source imaging can be a powerful tool in studying human brain functions with enhanced spatial and temporal resolutions. Recent studies on the combination of fMRI and EEG/MEG have suggested that fMRI prior information could be readily implemented by simply imposing different weighting factors to cortical sources overlapping with the fMRI activations. It has been also reported, however, that such a hard constraint may cause severe distortions or elimination of meaningful EEG/MEG sources when there are distinct mismatches between the fMRI activations and the EEG/MEG sources. If one wants to obtain the actual EEG/MEG source locations and uses the fMRI prior information as just an auxiliary tool to enhance focality of the distributed EEG/MEG sources, it is reasonable to weaken the strength of fMRI constraint when severe mismatches between fMRI and EEG/MEG sources are observed. The present study suggests an efficient technique to automatically adjust the strength of fMRI constraint according to the mismatch level. The use of the proposed technique rarely affects the results of conventional fMRI-constrained EEG/MEG source imaging if no major mismatch between the two modalities is detected; while the new results become similar to those of typical EEG/MEG source imaging without fMRI constraint if the mismatch level is significant. A preliminary simulation study using realistic EEG signals demonstrated that the proposed technique can be a promising tool to selectively apply fMRI prior information to EEG/MEG source imaging

  12. Tracer studies of flotation in laboratory and plant

    International Nuclear Information System (INIS)

    Niemi, A.J.; Thereska, J.; Plasari, E.; Kacaj, M.

    1992-01-01

    Froth flotation is used for the industrial extraction of valuable minerals from ores. Its progress depends on the properties of minerals being processed and on flotation practices. While flotation is basically a kinetic process, it functions industrially in continuous flow vessels whose flow patterns influence the separation effected. Radioisotope tracers have proven to be a necessary tool in the acquisition of both kinetic and flow pattern data

  13. Mixed-effects and fMRI studies

    DEFF Research Database (Denmark)

    Friston, K.J; Stephan, K.E; Ellegaard Lund, Torben

    2005-01-01

    This note concerns mixed-effect (MFX) analyses in multisession functional magnetic resonance imaging (fMRI) studies. It clarifies the relationship between mixed-effect analyses and the two-stage 'summary statistics' procedure (Holmes, A.P., Friston, K.J., 1998. Generalisability, random effects...

  14. New SPECT tracers: Example of tracers of proteoglycans and melanin

    International Nuclear Information System (INIS)

    Cachin, F.; Mestas, D.; Kelly, A.; Merlin, C.; Veyre, A.; Maublant, J.; Cachin, F.; Chezal, J.M.; Miot-Noirault, E.; Moins, N.; Auzeloux, P.; Vidal, A.; Bonnet-Duquennoy, M.; Boisgard, S.; D'Incan, M.; Madelmont, J.C.; Maublant, J.; Boisgard, S.; D'Incan, M.; Redini, F.; Filaire, M.

    2009-01-01

    The majority of research program on new radiopharmaceuticals turn to tracers used for positron emission tomography (PET). Only a few teams work on new non fluorine labeled tracers. However, the coming of SPECT/CT gamma cameras, the arrival of semi-conductors gamma cameras should boost the development of non-PET tracers. We exhibit in this article the experience acquired by our laboratory in the conception and design of two new non fluorine labelled compounds. The 99m Tc-N.T.P. 15-5 (N.T.P. 15-5 for N-[tri-ethyl-ammonium]-3-propyl-[15]ane-N5) which binds to proteoglycans could be used for the diagnosis and staging of osteoarthritis and chondrosarcoma. The iodo benzamides, specific to the melanin, are nowadays compared to 18 F-fluorodeoxyglucose in a phase III clinical trial for the diagnosis and detection of melanoma metastasis. Our last development focus on N-[2-(diethyl-amino)ethyl]-4 and 2-iodo benzamides respectively B.Z.A. and B.Z.A.2 hetero-aromatic analogues usable for melanoma treatment. (authors)

  15. Positron emitting tracers for studies of cocaine

    International Nuclear Information System (INIS)

    Fowler, J.S.; Gatley, S.J.; MacGregor, R.R.; Wolf, A.P.; Yu, D.W.; Dewey, S.L.; Schlyer, D.J.; Volkow, N.D.; Bendriem, B.; Logan, J.

    1990-01-01

    The use of PET to study the behavior and mechanism of action of therapeutic drugs and substances of abuse can be approached from a number of perspectives. The most common approach is to measure the effect of a drug on some aspect of metabolism and requires well characterized radiotracers whose behavior in vivo can be related to a discrete biochemical transformation. A second approach is to study the labeled drug itself. This provides information on the drug's regional distribution and kinetics as well as its pharmacological profile and metabolism. Cocaine has been labeled in different positions with carbon-11 and with fluorine-18 and the stereoisomers of cocaine have also been labeled to characterize its binding and metabolism in human and baboon brain. Regional cocaine binding as measured by PET is consistent with reversible binding to striatal dopamine reuptake sites and its time course parallels the behavioral activation of cocaine. The behaviorally inactive enantiomer (+)-cocaine is rapidly metabolized in serum preventing its entry into the brain. These PET tracers are useful in understanding the neurochemical basis of cocaine's action

  16. Contribution of radioactive tracers to sediment transport study in fluvial flows

    International Nuclear Information System (INIS)

    Wilson Junior, G.

    1995-01-01

    The uses of radioactive tracers in sediment transport studies are presented in this report to evidence the importance of: Open channel researches, to describe field applications in waterways; Simultaneous utilization of classical methods and radiotracer techniques, in fluvial and estuarine environments; Development of radiotracers techniques applied in dynamic sedimentology. The report illustrated with some experiments carried out in Brazil and France, in open channel and natural flows. (author). 5 refs, 4 figs

  17. STUDY OF POSTERIOR FOSSA TUMORS BY HIGH RESOLUTION MRI

    Directory of Open Access Journals (Sweden)

    Sree Hari

    2016-01-01

    Full Text Available INTRODUCTION Magnetic Resonance Imaging (MRI is the imaging modality used for the assessment of infratentorial neoplasms. Although Computed Tomography (CT provides better demonstration of small or subtle calcifications within tumors. OBJECTIVES Study is done to assess the potential of MRI in characterisation of different tumors in posterior fossa by evaluating various unenhanced and gadolinium enhanced sequences and to compare high resolution FSE MRI sequences with routine FSE MRI sequences in diagnosing posterior fossa brain tumors. Also correlate findings on Magnetic Resonance Imaging with Pathological diagnosis. MATERIALS AND METHODS A total of 52 patients were diagnosed by CT brain as having posterior fossa brain for a year of 2 years were included in the study. In all studies MR imaging was performed with a clinical 1.5 T system (General electrical medical systems. A dedicated phased-array coil was used. RESULTS The age group ranged from 1 year to 60 years, majority were between 1 to 20 years (39%. Slight male preponderance was seen (males 29, females 23. Commonest tumor encountered in our study was vestibular schwannoma. DWI alone can differentiate different pediatric posterior fossa brain tumors. One case of pilocytic astrocytoma showed solid lesion instead of typical cystic lesion with mural nodule. One case AT-RT showed 2 lesions one in cerebrum, one in CP angle. Common feature being intra-axial lesion involving cerebellum. MRI was able to predict diagnosis in 50 of the 52 tumors. CONCLUSION Magnetic Resonance Imaging was found to be a highly sensitive imaging procedure and method of choice for posterior fossa brain tumors.

  18. Disinfection Contact Time study plan (100-N Area tracer protocol). Revision 1

    International Nuclear Information System (INIS)

    Kretzschmar, S.P.; Bedi, G.S.; Martinez, P.; Ervin, K.

    1996-07-01

    Bechtel Hanford, Inc. will prepare an Engineering Tracer Study Protocol for the determination of contact time for the disinfection process at Group A Non-transient Non-community water treatment plant for the 100-N Water Plant at the Hanford Site in Richland, Washington. Included in this report are the results of a study that determine the actual detention time within the plant clearwell, and thus the disinfection contact time at several clearwell effluent flow rates

  19. Nested Tracer Studies In Catchment Hydrology: Towards A Multiscale Understanding of Runoff Generation and Catchment Funtioning

    Science.gov (United States)

    Soulsby, C.; Rodgers, P.; Malcolm, I. A.; Dunn, S.

    Geochemical and isotopic tracers have been shown to have widespread utility in catch- ment hydrology in terms of identifying hydrological source areas and characterising residence time distributions. In many cases application of tracer techniques has pro- vided insights into catchment functioning that could not be obtained from hydromet- ric and/or modelling studies alone. This paper will show how the use of tracers has contributed to an evolving perceptual model of hydrological pathways and runoff gen- eration processes in catchments in the Scottish highlands. In particular the paper will focus on the different insights that are gained at three different scales of analysis; (a) nested sub-catchments within a mesoscale (ca. 200 square kilometers) experimen- tal catchment; (b) hillslope-riparian interactions and (c) stream bed fluxes. Nested hydrometric and hydrochemical monitoring within the mesoscale Feugh catchment identified three main hydrological response units: (i) plateau peatlands which gener- ated saturation overland flow in the catchment headwaters, (ii) steep valley hillslopes which drain from the plateaux into (iii) alluvial and drift aquifers in the valley bottoms. End Member Mixing Analysis (EMMA) in 8 nested sub-catchments indicated that that stream water tracer concentrations can be modelled in terms of 2 dominant runoff pro- cesses; overland flow from the peat and groundwater from the drift aquifers. Ground- water contributions generally increased with catchment size, though this was moder- ated by the characteristics of individual sub-basins, with drift cover being particularly important. Hillslope riparian interactions were also examined using tracers, hydromet- ric data and a semi-distributed hydrological model. This revealed that in the glaciated, drift covered terrain of the Scottish highlands, extensive valley bottom aquifers effec- tively de-couple hillslope waters from the river channel. Thus, riparian groundwater appears to significantly

  20. Tracer-based quantification of individual frac discharge in single-well multiple-frac backflow: sensitivity study

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2014-05-01

    Within the deep-geothermal research project at GroßSchönebeck in the NE German Basin, targeting volcanic rocks (Lower Rotliegend) and siliciclastics (Upper Rotliegend) in the Lower Permian by means of a well doublet with several screening intervals between 3815 and 4247 m b.s.l., several artificial fractures with different geometric and hydraulic characteristics were created at each well, aiming to increase reservoir performance [1], [2]. It could not be told a priori which of the various fracturing treatments was to prove as most promising in terms of future reservoir productivity. At the intended-production well (GS-4), one large-area waterfrac was created in the low-permeability volcanic rocks, and two gel-proppant fractures in selected sandstone layers. Each fracturing treatment was accompanied by the injection of a water-dissolved tracer slug, followed by a defined volume of tracer-free ('chaser') fluid [3]. Each frac received a different species of a sulfonated aromatic acid salt, as a conservative water tracer. During subsequent backflow tests (either gas-based lifting, or production by means of a downhole submersible pump), each frac can contribute a certain (more or less constant) amount to the measured total discharge (also depending on whether and when each frac 'starts' contributing, and which effective aperture and area it actually 'manifests' during the process). Since these individual-frac discharge amounts cannot be measured directly, it was endeavoured to indirectly determine ('resolve') them from tracer signals as detectable in the overall backflow discharge. Therefore, we need to examine how these tracer signals depend on local discharge values and on local hydrogeologic parameters (matrix porosity, permeability distribution; frac transmissivity, thickness, effective area and aperture), and to what extent hydrogeological uncertainty will impede the inversion of local discharge values. To this end, a parameter sensitivity study was conducted on

  1. Laplace transform in tracer kinetic modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Eliete B., E-mail: eliete@pucrs.br [Instituto do Cerebro (InsCer/FAMAT/PUC-RS), Porto Alegre, RS, (Brazil). Faculdade de Matematica

    2013-07-01

    The main objective this paper is to quantify the pharmacokinetic processes: absorption, distribution and elimination of radiopharmaceutical(tracer), using Laplace transform method. When the drug is administered intravenously absorption is complete and is available in the bloodstream to be distributed throughout the whole body in all tissues and fluids, and to be eliminated. Mathematical modeling seeks to describe the processes of distribution and elimination through compartments, where distinct pools of tracer (spatial location or chemical state) are assigned to different compartments. A compartment model is described by a system of differential equations, where each equation represents the sum of all the transfer rates to and from a specific compartment. In this work a two-tissue irreversible compartment model is used for description of tracer, [{sup 18}F]2-fluor-2deoxy-D-glucose. In order to determine the parameters of the model, it is necessary to have information about the tracer delivery in the form of an input function representing the time-course of tracer concentration in arterial blood or plasma. We estimate the arterial input function in two stages and apply the Levenberg-Marquardt Method to solve nonlinear regressions. The transport of FDG across de arterial blood is very fast in the first ten minutes and then decreases slowly. We use de Heaviside function to represent this situation and this is the main contribution of this study. We apply the Laplace transform and the analytical solution for two-tissue irreversible compartment model is obtained. The only approach is to determinate de arterial input function. (author)

  2. Study of transport in unsaturated sands using radioactive tracers

    International Nuclear Information System (INIS)

    Merritt, W.F.; Pickens, J.F.; Allison, G.B.

    1979-01-01

    A laboratory experiment was conducted to investigate the mixing that occurs as a series of labelled pulses of water are transported by gravity drainage down through a sand filled column having a water table imposed at the bottom. It also demonstrated the utility of gamma-ray emitting radioactive tracers in studying transport in unsaturated or saturated porous media. The motivation for pursuing this topic was developed from observing that the content of oxygen-18, deuterium and tritium in rainwater shows marked temporal variations whereas their concentrations below the water table in shallow ground water flow systems are generally found to show much less variation. (auth)

  3. Experiences of simulated tracer dispersal studies using effluent discharges at Tarapur aquatic environment

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Sawane, Pratibha; Rao, D.D.; Hegde, A.G.

    2007-01-01

    The nuclear complex in Tarapur, Maharashtra is a multi facility nuclear site comprising of power reactors and research facilities. Each facility has independent liquid effluent discharge line to Arabian Sea. Experimental studies were conducted to evaluate dilution factors in the aquatic environment using liquid effluent releases as tracer from one of the facilities. 3 H and 137 Cs radioisotopes present in the routine releases were used as simulated tracer nuclides. The dilution factors(D.F) observed for tritium were in the range of 20-20000 in a distance range of 10 m to 1500 m respectively and for 137 Cs the D.F. were in the range of 50 to 900 over a distance range of 10-200 m. The paper describes the analytical methodology and sampling scenarios and the results of dilution factors obtained for Tarapur aquatic environment. (author)

  4. 3-D migration experiment - report 2: Instrumentation and tracers

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Gidlund, J.

    1987-11-01

    This report is one of the four reports describing the Stripa 3D experiment where water and tracer flow has been monitored in a specially excavated drift in the Stripa mine. The experiment was performed in a specially excavated drift at the 360 m level in granite. The whole ceiling and upper part of the walls were covered with more than 350 individual plastic sheets where the water flow into the drift could be collected. 11 different tracers were injected at distances between 11 and 50 m from the ceiling of the drift. The flow rate and tracer monitoring was kept up for more than two years. The tracer breakthrough curves and flow rate distributions were used to study the flow paths, velocities, hydraulic conductivities, dispersivities and channeling effects in the rock. The report describes the instrumentation developed and used as well as the tracers that were tested and used in the experiment. (orig.)

  5. Using neural networks to describe tracer correlations

    Directory of Open Access Journals (Sweden)

    D. J. Lary

    2004-01-01

    Full Text Available Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and methane volume mixing ratio (v.m.r.. In this study a neural network using Quickprop learning and one hidden layer with eight nodes was able to reproduce the CH4-N2O correlation with a correlation coefficient between simulated and training values of 0.9995. Such an accurate representation of tracer-tracer correlations allows more use to be made of long-term datasets to constrain chemical models. Such as the dataset from the Halogen Occultation Experiment (HALOE which has continuously observed CH4  (but not N2O from 1991 till the present. The neural network Fortran code used is available for download.

  6. Tracer dispersion - experiment and CFD

    International Nuclear Information System (INIS)

    Zitny, R.

    2004-01-01

    Description of tracer distribution by means of dispersion models is a method successfully used in process engineering for fifty years. Application of dispersion models in reactor engineering for characterization of flows in column apparatus, heat exchangers, etc. is summarized and experimental tracer techniques as well as CFD methods for dispersion coefficients evaluation are discussed. Possible extensions of thermal axial dispersion model (ADM) and a core-wall ADM model suitable for description of tracer dispersion in laminar flows are suggested as well as CFD implementation as 1D finite elements. (author)

  7. Selection of tracers for oil and gas evaluation

    International Nuclear Information System (INIS)

    Bjoernstad, T.

    1991-08-01

    The importance of tracer tests in reservoir descriptions is increasingly acknowledged by reservoir engineers as a method to obtain valuable dynamic information from the reservoir. The report describes the ''state-of-the art'' on tracer technology for interwell investigations. Experiences gained from a number of reported field tracer tests are reviewed, and results from detailed laboratory investigations on the static and dynamic behavior of various tracer molecules are discussed. A critical evaluation of the applicability of the various identified tracers is provided. Present and future trends in the development of tracer technology for reservoir description are sketched. 64 refs., 12 figs., 2 tabs

  8. Hydrophilic and lipophilic radiopharmaceuticals as tracers in pharmaceutical development: In vitro – In vivo studies

    International Nuclear Information System (INIS)

    Terán, Mariella; Savio, Eduardo; Paolino, Andrea; Frier, Malcolm

    2005-01-01

    Scintigraphic studies have been performed to assess the release, both in vitro and in vivo, of radiotracers from tablet formulations. Four different tracers with differing physicochemical characteristics have been evaluated to assess their suitability as models for drug delivery. In-vitro disintegration and dissolution studies have been performed at pH 1, 4 and 7. In-vivo studies have been performed by scintigraphic imaging in healthy volunteers. Two hydrophilic tracers, ( 99m Tc-DTPA) and ( 99m Tc-MDP), and two lipophilic tracers, ( 99m Tc-ECD) and ( 99m Tc-MIBI), were used as drug models. Dissolution and disintegration profiles, differed depending on the drug model chosen. In vitro dissolution velocity constants indicated a probable retention of the radiotracer in the formulation. In vivo disintegration velocity constants showed important variability for each radiopharmaceutical. Pearson statistical test showed no correlation between in vitro drug release, and in vivo behaviour, for 99m Tc-DTPA, 99m Tc-ECD and 99m Tc-MIBI. High correlation coefficients were found for 99m Tc-MDP not only for in vitro dissolution and disintegration studies but also for in vivo scintigraphic studies. Scintigraphic studies have made a significant contribution to the development of drug delivery systems. It is essential, however, to choose the appropriate radiotracers as models of drug behaviour. This study has demonstrated significant differences in release patterns, depending on the model chosen. It is likely that each formulation would require the development of a specific model, rather than being able to use a generic drug model on the basis of its physicochemical characteristics

  9. Halon-1301, a new Groundwater Age Tracer

    Science.gov (United States)

    Beyer, Monique; van der Raaij, Rob; Morgenstern, Uwe; Jackson, Bethanna

    2015-04-01

    Groundwater dating is an important tool to assess groundwater resources in regards to direction and time scale of groundwater flow and recharge and to assess contamination risks and manage remediation. To infer groundwater age information, a combination of different environmental tracers, such as tritium and SF6, are commonly used. However ambiguous age interpretations are often faced, due to a limited set of available tracers and limitations of each tracer method when applied alone. There is a need for additional, complementary groundwater age tracers. We recently discovered that Halon-1301, a water soluble and entirely anthropogenic gaseous substance, may be a promising candidate [Beyer et al, 2014]. Halon-1301 can be determined along with SF6, SF5CF3 and CFC-12 in groundwater using a gas chromatography setup with attached electron capture detector developed by Busenberg and Plummer [2008]. Halon-1301 has not been assessed in groundwater. This study assesses the behaviour of Halon-1301 in water and its suitability as a groundwater age tracer. We determined Halon-1301 in 17 groundwater and various modern (river) waters sites located in 3 different groundwater systems in the Wellington Region, New Zealand. These waters have been previously dated with tritium, CFC-12, CFC-11 and SF6 with mean residence times ranging from 0.5 to over 100 years. The waters range from oxic to anoxic and some show evidence of CFC contamination or degradation. This allows us to assess the different properties affecting the suitability of Halon-1301 as groundwater age tracer, such as its conservativeness in water and local contamination potential. The samples are analysed for Halon-1301 and SF6simultaneously, which allows identification of issues commonly faced when using gaseous tracers such as contamination with modern air during sampling. Overall we found in the assessed groundwater samples Halon-1301 is a feasible new groundwater tracer. No sample indicated significantly elevated

  10. Systems approach to tracer data in groundwater hydrology

    International Nuclear Information System (INIS)

    Saxena, R.K.

    1977-01-01

    A brief review of current mathematical methods for the analysis of tracer data in groundwater hydrology has been given. The description of the hydrological cycle as a whole or in part, by a system (compartment) or sub-system under linear and stationary conditions is discussed. Basic concepts of transit time, residence time, their distributions in time and response characteristics of a system are outlined. From the knowledge of tracer input, output and systems response function for a generalised system, reservoir capacity and storage for given period can be estimated. Use of a time series model for environmental tracer data in discreet time scale aimed at the solution of hydrological problems e.g. mean transit time and reservoir capacity is also explored. It is concluded that the combination of tracer data with systems approach can go a long way in the study of some complex hydrological problems. (author)

  11. Fluorinated tracers for imaging cancer with positron emission tomography

    International Nuclear Information System (INIS)

    Couturier, Olivier; Chatal, Jean-Francois; Luxen, Andre; Vuillez, Jean-Philippe; Rigo, Pierre; Hustinx, Roland

    2004-01-01

    2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is currently the only fluorinated tracer used in routine clinical positron emission tomography (PET). Fluorine-18 is considered the ideal radioisotope for PET imaging owing to the low positron energy (0.64 MeV), which not only limits the dose rate to the patient but also results in a relatively short range of emission in tissue, thereby providing high-resolution images. Further, the 110-min physical half-life allows for high-yield radiosynthesis, transport from the production site to the imaging site and imaging protocols that may span hours, which permits dynamic studies and assessment of potentially fairly slow metabolic processes. The synthesis of fluorinated tracers as an alternative to FDG was initially tested using nucleophilic fluorination of the molecule, as performed when radiolabelling with iodine-124 or bromide-76. However, in addition to being long, with multiple steps, this procedure is not recommended for bioactive molecules containing reactive groups such as amine or thiol groups. Radiochemical yields are also often low. More recently, radiosynthesis from prosthetic group precursors, which allows easier radiolabelling of biomolecules, has led to the development of numerous fluorinated tracers. Given the wide availability of 18 F, such tracers may well develop into important routine tracers. This article is a review of the literature concerning fluorinated radiotracers recently developed and under investigation for possible PET imaging in cancer patients. Two groups can be distinguished. The first includes ''generalist'' tracers, i.e. tracers amenable to use in a wide variety of tumours and indications, very similar in this respect to FDG. These are tracers for non-specific cell metabolism, such as protein synthesis, amino acid transport, nucleic acid synthesis or membrane component synthesis. The second group consists of ''specific'' tracers for receptor expression (i.e. oestrogens or somatostatin), cell

  12. Functional MRI in human motor control studies and clinical applications

    International Nuclear Information System (INIS)

    Toma, Keiichiro

    2002-01-01

    Functional magnetic resonance imaging (fMRI) has been a useful tool for the noninvasive mapping of brain function associated with various motor and cognitive tasks. Because fMRI is based on the blood oxygenation level dependent (BOLD) effect, it does not directly record neural activity. With the fMRI technique, distinguishing BOLD signals creased by cortical projection neurons from those created by intracortical neurons appears to be difficult. Two major experimental designs are used in fMRI studies: block designs and event-related designs. Block-designed fMRI presupposes the steady state of regional cerebral blood flow and has been applied to examinations of brain activation caused by tasks requiring sustained or repetitive movements. By contrast, the more recently developed event-related fMRI with time resolution of a few seconds allows the mapping of brain activation associated with a single movement according to the transient aspects of the hemodynamic response. Increasing evidence suggests that multiple motor areas are engaged in a networked manner to execute various motor acts. In order to understand functional brain maps, it is important that one understands sequential and parallel organizations of anatomical connections between multiple motor areas. In fMRI studies of complex motor tasks, elementary parameters such as movement length, force, velocity, acceleration and frequency should be controlled, because inconsistency in those parameters may alter the extent and intensity of motor cortical activation, confounding interpretation of the findings obtained. In addition to initiation of movements, termination of movements plays an important role in the successful achievement of complex movements. Brain areas exclusively related to the termination of movements have been, for the first time, uncovered with an event-related fMRI technique. We propose the application of fMRI to the elucidation of the pathophysiology of movement disorders, particularly dystonia

  13. Functional MRI in human motor control studies and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Toma, Keiichiro [Kyoto Univ. (Japan). Graduate School of Medicine; Nakai, Toshiharu [Inst. of Biomedical Research and Innovation, Kobe (Japan)

    2002-07-01

    Functional magnetic resonance imaging (fMRI) has been a useful tool for the noninvasive mapping of brain function associated with various motor and cognitive tasks. Because fMRI is based on the blood oxygenation level dependent (BOLD) effect, it does not directly record neural activity. With the fMRI technique, distinguishing BOLD signals creased by cortical projection neurons from those created by intracortical neurons appears to be difficult. Two major experimental designs are used in fMRI studies: block designs and event-related designs. Block-designed fMRI presupposes the steady state of regional cerebral blood flow and has been applied to examinations of brain activation caused by tasks requiring sustained or repetitive movements. By contrast, the more recently developed event-related fMRI with time resolution of a few seconds allows the mapping of brain activation associated with a single movement according to the transient aspects of the hemodynamic response. Increasing evidence suggests that multiple motor areas are engaged in a networked manner to execute various motor acts. In order to understand functional brain maps, it is important that one understands sequential and parallel organizations of anatomical connections between multiple motor areas. In fMRI studies of complex motor tasks, elementary parameters such as movement length, force, velocity, acceleration and frequency should be controlled, because inconsistency in those parameters may alter the extent and intensity of motor cortical activation, confounding interpretation of the findings obtained. In addition to initiation of movements, termination of movements plays an important role in the successful achievement of complex movements. Brain areas exclusively related to the termination of movements have been, for the first time, uncovered with an event-related fMRI technique. We propose the application of fMRI to the elucidation of the pathophysiology of movement disorders, particularly dystonia

  14. Tracer techniques in microelectronics

    International Nuclear Information System (INIS)

    Flachowsky, J.; Freyer, K.

    1981-01-01

    Tracer technique and neutron activation analysis are capable of measuring impurities in semiconductor material or on the semiconductor surface in a very low concentration range. The methods, combined with autoradiography, are also suitable to determine dopant distributions in silicon. However, both techniques suffer from certain inherent experimental difficulties and/or limitations which are discussed. Methods of tracer technique practicable in the semiconductor field are described. (author)

  15. Numerical Simulation of a Tracer Experiment at the Wolsong Nuclear Site

    International Nuclear Information System (INIS)

    Jeong, Hyojoon; Kim, Eunhan; Park, Misun; Jeong, Haesun; Hwang, Wontae; Han, Moonhee

    2014-01-01

    By comparing the concentration of a tracer measured under weather conditions that are disadvantageous to the dilution of radioactive materials released from the Wolsong Nuclear Power Plant, with the concentration of a tracer calculated using an air Dispersion model, it is possible to evaluate the characteristics of the air concentrations of radioactive materials estimated with an air Dispersion model, which can then be used in an environmental impact analysis of radioactive materials. Therefore, a field Dispersion experiment has been carried out to figure out the behavioral characteristics of the tracer under weather conditions that are disadvantageous to the dilution of radioactive materials released from the Wolsong Nuclear Power Plant site in Korea. In addition, through a comparison of the tracer concentrations estimated by the Gaussian plume model with measurements, this study checked the degree of conservative estimation for the Gaussian plume at the Wolsong nuclear site in Korea. A tracer Dispersion experiment using an SF 6 trace was implemented to determine the Dispersion characteristics of radioactive materials at the Wolsong Nuclear Power Plant site in Korea. Based on meteorological data and the emission rate of the tracers, this study estimated the tracer concentrations using a Gaussian plume model, and then compared it with the measurement to check the conservative estimation of the Gaussian plume model. The measured concentrations of the tracer tends to be lower than the concentrations estimated by the Gaussian plume model overall

  16. MRI Compatibility of Robot Actuation Techniques – A Comparative Study

    OpenAIRE

    Fischer, Gregory S.; Krieger, Axel; Iordachita, Iulian; Csoma, Csaba; Whitcomb, Louis L.; Fichtinger, Gabor

    2008-01-01

    This paper reports an experimental evaluation of the following three different MRI-compatible actuators: a Shinsei ultrasonic motor, a Nanomotion ultrasonic motor and a pneumatic cylinder actuator. We report the results of a study comparing the effect of these actuators on the signal to noise ratio (SNR) of MRI images under a variety of experimental conditions. Evaluation was performed with the controller inside and outside the scanner room and with both 1.5T and 3T MRI scanners. Pneumatic cy...

  17. Assessment of swallowing and its disorders—A dynamic MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Vijay Kumar, K.V., E-mail: vijaykumarkv@yahoo.in [Department of Speech, Language and Hearing Sciences, SRU (India); Shankar, V., E-mail: drshankarv@yahoo.co.in [Department of Neurology, SRU (India); Santosham, Roy, E-mail: santoshamroy@yahoo.com [Department of Radiology and Imaging Sciences, SRU (India)

    2013-02-15

    Magnetic resonance imaging overcomes the limitations of videofluoroscopy in assessing without radiation exposure. The clinical utility of dynamic MRI for swallowing disorders is not well documented. This study demonstrates the feasibility of using dynamic MRI in assessment of swallowing disorders. Ten normal and three brainstem lesion patients participated in this study. GE Signa HDxt 1.5 Tesla MRI scanner with head-and-neck coil as a receiver and fast imaging employing steady state acquisition sequence was used. The swallow was analyzed in terms of symmetry and amplitude of movements of velum, faucial pillars, tongue, epiglottis and cricopharyngeous and images from the sagittal, coronal and axial planes. In sagittal plane posterior movement of tongue and its compression on velum, elevation of hyoid bone, elevation of larynx and lid action of epiglottis, in the coronal view the symmetrical movements of the faucial pillars and pharyngeal constrictor muscles and in axial plane three anatomical landmarks were targeted based on their role in swallowing, viz. velum, epiglottis and cricopharyngeous were studied. In brainstem lesion individuals, posterior movement of tongue, and elevation of larynx were not seen. Asymmetrical movements of faucial pillars and cricopharyngeous muscle were appreciated in the dynamic MRI. This demonstrates that, dynamic MRI is an efficient tool to understand the swallowing physiology and helps the speech language pathologist in modifying the swallowing maneuvers. Dynamic MRI is an effective tool in assessing swallowing and its disorders. This muscle specific information is not appreciated in videofluoroscopy and this information is necessary to modify the therapy maneuvers.

  18. Assessment of swallowing and its disorders—A dynamic MRI study

    International Nuclear Information System (INIS)

    Vijay Kumar, K.V.; Shankar, V.; Santosham, Roy

    2013-01-01

    Magnetic resonance imaging overcomes the limitations of videofluoroscopy in assessing without radiation exposure. The clinical utility of dynamic MRI for swallowing disorders is not well documented. This study demonstrates the feasibility of using dynamic MRI in assessment of swallowing disorders. Ten normal and three brainstem lesion patients participated in this study. GE Signa HDxt 1.5 Tesla MRI scanner with head-and-neck coil as a receiver and fast imaging employing steady state acquisition sequence was used. The swallow was analyzed in terms of symmetry and amplitude of movements of velum, faucial pillars, tongue, epiglottis and cricopharyngeous and images from the sagittal, coronal and axial planes. In sagittal plane posterior movement of tongue and its compression on velum, elevation of hyoid bone, elevation of larynx and lid action of epiglottis, in the coronal view the symmetrical movements of the faucial pillars and pharyngeal constrictor muscles and in axial plane three anatomical landmarks were targeted based on their role in swallowing, viz. velum, epiglottis and cricopharyngeous were studied. In brainstem lesion individuals, posterior movement of tongue, and elevation of larynx were not seen. Asymmetrical movements of faucial pillars and cricopharyngeous muscle were appreciated in the dynamic MRI. This demonstrates that, dynamic MRI is an efficient tool to understand the swallowing physiology and helps the speech language pathologist in modifying the swallowing maneuvers. Dynamic MRI is an effective tool in assessing swallowing and its disorders. This muscle specific information is not appreciated in videofluoroscopy and this information is necessary to modify the therapy maneuvers

  19. Clinical significance of abnormal nonosseous soft tissue uptake of bone tracer

    International Nuclear Information System (INIS)

    Zhu Bao; Shang Yukun; Li Jiannan; Bai Jing; Cai Liang

    2006-01-01

    Objective: To evaluate the clinical significance of abnormal soft tissue uptake of bone tracer. Methods: Thirty patients with abnormal soft tissue uptake of bone tracer on 99 Tc m -methylene diphosphonic acid (MDP) skeletal imaging were analyzed. Radioactivity of soft tissue accumulated equal to or greater than the ribs were considered as abnormal. The result was compared with pathology, MRI, CT, X-ray, ultrasound, findings for evaluating its clinical significance. Results: In 7 patients with diffuse liver uptake of 99 Tc m -MDP, 6 were massive and 1 nodular liver cancer. In 2 patients with local liver uptake, one was metastatic and the other primary liver cancer. In 5 local lung uptake cases 4 were primary lung cancer and one metastatic. In 5 cases with colonic uptake 1 was schistosomiasis while the other 4 unexplainable. Subcutaneous tissue uptake was observed in 4 patients, symmetrical uptake in 2 patients with metastatic calcification microfoci in multiple myeloma, unsymmetrical uptake in 2 patients with hemangioma and abscess. Pleural uptake in 3 patients all was metastatic cancer. Abdominal uptake in 3 patients was omentum, paravertebral soft tissue metastasis and unknown cause. Breast uptake in one patient was due to breast cancer. Conclusions: There are many causes resulting in abnormal nonosseous soft tissue uptake of 99 Tc m -MDP. The final diagnosis should correlate with clinical data and other examinations. (authors)

  20. Signal to noise comparison of metabolic imaging methods on a clinical 3T MRI

    DEFF Research Database (Denmark)

    Müller, C. A.; Hansen, Rie Beck; Skinner, J. G.

    MRI with hyperpolarized tracers has enabled new diagnostic applications, e.g. metabolic imaging in cancer research. However, the acquisition of the transient, hyperpolarized signal with spatial and frequency resolution requires dedicated imaging methods. Here, we compare three promising candidate...... for 2D MR spectroscopic imaging (MRSI): (i) multi-echo balanced steady-state free precession (me-bSSFP), 1,2 (ii) echo planar spectroscopic imaging (EPSI) sequence and (iii) phase-encoded, pulseacquisition chemical-shift imaging (CSI)...

  1. Field studies of transport and dispersion of atmospheric tracers in nocturnal drainage flows

    Science.gov (United States)

    Paul H. Gudiksen; Gilbert J. Ferber; Malcolm M. Fowler; Wynn L. Eberhard; Michael A. Fosberg; William R. Knuth

    1984-01-01

    A series of tracer experiments were carried out as part of the Atmospheric Studies in Complex Terrain (ASCOT) program to evaluate pollutant transport and dispersion characteristics of nocturnal drainage flows within a valley in northern California. The results indicate that the degree of interaction of the drainage flows with the larger scale regional flows are...

  2. GTS-LCS, in-situ experiment 2. Modeling of tracer test 09-03

    International Nuclear Information System (INIS)

    Manette, M.; Saaltink, M.W.; Soler, J.M.

    2015-02-01

    Within the framework of the GTS-LCS project (Grimsel Test Site - Long-Term Cement Studies), an in-situ experiment lasting about 5 years was started in 2009 to study water-cement-rock interactions in a fractured granite. Prior to the experiment, a tracer test was performed to characterize the initial flow and transport properties of the rock around the experimental boreholes. This study reports on the model interpretation of tracer test 09-03. The calculations were performed by means of a two-dimensional model (homogeneous fracture plane including 3 boreholes) using the Retraso-CodeBright software package. In the tracer test, Grimsel groundwater containing the tracer (uranine) was circulated in the emplacement borehole during 43 days (zero injection flow rate). Circulation continued without tracer afterwards. Water was extracted at the observation and extraction boreholes. Results from a model sensitivity analysis comparing model results with measured tracer concentrations showed 3 cases where the evolution of tracer concentrations in the 3 different boreholes was satisfactory. In these cases a low-permeability skin affected the emplacement and observation boreholes. No skin appeared to affect the extraction borehole. The background hydraulic gradient seems to have no effect on the results of the tracer test. These results will be applied in the calculation of the initial flow field for the reactive transport phase of in-situ experiment 2 (interaction between pre-hardened cement and fractured granite at Grimsel). (orig.)

  3. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    Energy Technology Data Exchange (ETDEWEB)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasma measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.

  4. The diagnostic and therapeutic impact of MRI: an observational multi-centre study

    International Nuclear Information System (INIS)

    Hollingworth, William; Todd, Christopher J.; Bell, Matthew I.; Arafat, Qais; Girling, Simon; Karia, Kanti R.; Dixon, Adrian K.

    2000-01-01

    AIM: To provide information about the diagnostic and therapeutic impact of magnetic resonance imaging (MRI) and to compare the findings across diagnostic groups. MATERIALS AND METHODS: A prospective, observational study of 2017 consecutive referrals for MRI of the head, spine or knee at four imaging centres. Clinicians completed questionnaires before MRI stating initial diagnoses, diagnostic confidence and treatment plans. After imaging, a second questionnaire evaluated clinicians' revised diagnosis and treatment plans in the light of imaging findings. Patients were grouped into nine diagnostic categories for analysis. Comparison between pre- and post-imaging was used to assess the diagnostic and therapeutic impact of MRI. RESULTS: In seven of nine diagnostic groups MRI findings were associated with a diagnostic impact. Diagnoses were revised or discarded following normal MR findings and diagnostic confidence was increased by confirmative MR findings. There was no statistically significant diagnostic impact for suspected pituitary or cerebello-pontine angle lesions. In five of nine diagnostic groups (knee meniscus, knee ligament, multiple sclerosis, lumbar and cervical spine) MRI findings had a clear impact on treatment plans. CONCLUSION: This study demonstrates that in most diagnostic categories, MRI influences diagnosis and treatment. However, experimental studies are needed to prove that these diagnostic and therapeutic impacts lead to improved health. Hollingworth (2000)

  5. The diagnostic and therapeutic impact of MRI: an observational multi-centre study

    Energy Technology Data Exchange (ETDEWEB)

    Hollingworth, William; Todd, Christopher J.; Bell, Matthew I.; Arafat, Qais; Girling, Simon; Karia, Kanti R.; Dixon, Adrian K

    2000-11-01

    AIM: To provide information about the diagnostic and therapeutic impact of magnetic resonance imaging (MRI) and to compare the findings across diagnostic groups. MATERIALS AND METHODS: A prospective, observational study of 2017 consecutive referrals for MRI of the head, spine or knee at four imaging centres. Clinicians completed questionnaires before MRI stating initial diagnoses, diagnostic confidence and treatment plans. After imaging, a second questionnaire evaluated clinicians' revised diagnosis and treatment plans in the light of imaging findings. Patients were grouped into nine diagnostic categories for analysis. Comparison between pre- and post-imaging was used to assess the diagnostic and therapeutic impact of MRI. RESULTS: In seven of nine diagnostic groups MRI findings were associated with a diagnostic impact. Diagnoses were revised or discarded following normal MR findings and diagnostic confidence was increased by confirmative MR findings. There was no statistically significant diagnostic impact for suspected pituitary or cerebello-pontine angle lesions. In five of nine diagnostic groups (knee meniscus, knee ligament, multiple sclerosis, lumbar and cervical spine) MRI findings had a clear impact on treatment plans. CONCLUSION: This study demonstrates that in most diagnostic categories, MRI influences diagnosis and treatment. However, experimental studies are needed to prove that these diagnostic and therapeutic impacts lead to improved health. Hollingworth (2000)

  6. Studies on the electrochemical behaviour of iron by the use of radio-tracer technique, 1. Studies on the electrodeposition and dissolution of iron by the use of radio-tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Moritani, Kimikazu; Ito, Yasuhiko; Kamata, Masahiro; Oishi, Jun

    1984-12-01

    To investigate whether radio-tracer techniques can augment conventional electrochemical techniques, offering useful information about the electrochemical behaviour of iron, the current efficiency of the electrodeposition of iron and the corrosion rate of metallic iron were measured by the radio-tracer method and the results were compared with the results measured by gravimetry and absorption photometry. Major conclusions obtained by the experiments are summarized as: 1) Between ordinary Fe and /sup 59/Fe, no isotope effect was observed. 2) Radiation from /sup 59/Fe had no effect on the electrode reaction. 3) While the use of a Ge semiconductor detector is undoubtedly preferable, Geiger-Mueller counter or NaI(Tl) scintillation counter gave fully satisfactory results. 4) Electrodeposited iron corrodes several times more rapidly than the iron base metal. These results suggests many other interesting applications of the radio-tracer technique when it is desired to obtain more detailed information on the electrochemical behaviour of iron. (author).

  7. Root zone effects on tracer migration in arid zones

    International Nuclear Information System (INIS)

    Tyler, S.W.; Walker, G.R.

    1994-01-01

    The study of groundwater recharge and soil water movement in arid regions has received increased attention in the search for safe disposal sites for hazardous wastes. In passing through the upper 1 to 2 m of most soil profiles, tracers indicative of recharge such as Cl, 2 H, 18 O, Br, 3 H, and 56 Cl are subjected to a wide range of processes not encountered deeper in the profile. This transition zone, where water enters as precipitation and leaves as recharge, is often ignored when environmental tracers are used to estimate deep soil water flux and recharge, yet its effect may be profound. In this work, we reexamine the processes of root extraction and its effect on the velocity and distribution of tracers. Examples are presented for idealized conditions, which show clearly the relation between the root zone processes and the deep drainage or recharge. The results indicate that, when recharge is small and root zone processes are not accounted for, tracer techniques can significantly overestimate recharge until the tracer has moved well below the root zone. By incorporating simple models of root zone processes, a clearer understanding of tracer distributions and a more accurate estimate of recharge can then be made. 11 refs., 9 figs

  8. TracerLPM (Version 1): An Excel® workbook for interpreting groundwater age distributions from environmental tracer data

    Science.gov (United States)

    Jurgens, Bryant C.; Böhlke, J.K.; Eberts, Sandra M.

    2012-01-01

    TracerLPM is an interactive Excel® (2007 or later) workbook program for evaluating groundwater age distributions from environmental tracer data by using lumped parameter models (LPMs). Lumped parameter models are mathematical models of transport based on simplified aquifer geometry and flow configurations that account for effects of hydrodynamic dispersion or mixing within the aquifer, well bore, or discharge area. Five primary LPMs are included in the workbook: piston-flow model (PFM), exponential mixing model (EMM), exponential piston-flow model (EPM), partial exponential model (PEM), and dispersion model (DM). Binary mixing models (BMM) can be created by combining primary LPMs in various combinations. Travel time through the unsaturated zone can be included as an additional parameter. TracerLPM also allows users to enter age distributions determined from other methods, such as particle tracking results from numerical groundwater-flow models or from other LPMs not included in this program. Tracers of both young groundwater (anthropogenic atmospheric gases and isotopic substances indicating post-1940s recharge) and much older groundwater (carbon-14 and helium-4) can be interpreted simultaneously so that estimates of the groundwater age distribution for samples with a wide range of ages can be constrained. TracerLPM is organized to permit a comprehensive interpretive approach consisting of hydrogeologic conceptualization, visual examination of data and models, and best-fit parameter estimation. Groundwater age distributions can be evaluated by comparing measured and modeled tracer concentrations in two ways: (1) multiple tracers analyzed simultaneously can be evaluated against each other for concordance with modeled concentrations (tracer-tracer application) or (2) tracer time-series data can be evaluated for concordance with modeled trends (tracer-time application). Groundwater-age estimates can also be obtained for samples with a single tracer measurement at one

  9. The use of synthetic colloids in tracer transport experiments in saturated rock fractures

    International Nuclear Information System (INIS)

    Reimus, P.W.

    1995-08-01

    Studies of groundwater flow and contaminant transport in saturated, fractured geologic media are of great interest to researchers studying the potential long-term storage of hazardous wastes in or near such media. A popular technique for conducting such studies is to introduce tracers having different chemical and physical properties into a system and then observe the tracers at one or more downstream locations, inferring flow and transport mechanisms from the breakthrough characteristics of the different tracers. Many tracer studies have been conducted in saturated, fractured media to help develop and/or refine models capable of predicting contaminant transport over large scales in such media

  10. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    Science.gov (United States)

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  11. Underground flux studies in waste basin of CIPC using natural and artificial tracers - v.1

    International Nuclear Information System (INIS)

    Minardi, P.S.P.

    1982-10-01

    Underground flux studies in waste basin of CIPC is presented, with the description of the regions and the wells, the techniques with artificial tracers and the results and conclusion, based in field campaign realized till february/82. (author)

  12. The field tracer test study of atmospheric dispersion in Fujian Huian Nuclear Power Plant site

    International Nuclear Information System (INIS)

    Hu Erbang; Xin Cuntian; Yan Jiangyu; Ren Zhiqiang; Xuan Yiren; Jia Peirong

    2003-01-01

    The SF 6 tracer tests and its main results completed in site of Fujian Huian Nuclear Power Plant during summer, 2002, are described. A total of 15 times of SF 6 tracer tests were done in the July, in which the time of atmospheric stability B, C, D, E is respectively 3, 2, 9, 1 based on ΔT-U method and the time of B, D, E is respectively 1, 11, 3 based on ΔT method. About 50 samples were collected in each SF 6 tracer tests, the maximum of sample distance from the tower in which the SF 6 tracer was released is about 15 km. The values of p y , p z , q y , q z in the formula of diffusion parameters is determined. Finally the above diffusion parameters are compared with P-G curve, Briggs diffusion parameters and those obtained from turbulence observation and wind tunnel simulation test done in the past time. (authors)

  13. Tracer gas dispersion in ducts-study of a new compact device using arrays of sonic micro jets

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.R. [Instituto Nacional de Engenharia e Tecnologia Industrial (INETI), Lisboa (Portugal); Afonso, C.F. [Faculdade de Engenharia, Universidade do Porto Departmento de Mecanica e Gestao Industrial, Porto (Portugal)

    2004-07-01

    One of the most feasible ways to measure duct airflows is by tracer gas techniques, especially for complex situations when the duct lengths are short as well as their access, which makes extremely difficult or impossible other methods to be implemented. One problem associated with the implementation of tracer gas technique when the ducts lengths are short is due to the impossibility of achieving complete mixing of the tracer with airflow and its sampling. In this work, the development of a new device for the injection of tracer gas in ducts is discussed as well as a new tracer-sampling device. The developed injection device has a compact tubular shape, with magnetic fixation to be easy to apply in duct walls. An array of sonic micro jets in counter current direction, with the possibility of angular movement according to its main axle ensures a complete mixing of the tracer in very short distances. The tracer-sampling device, with a very effective integration function, feeds the sampling system for analysis. Both devices were tested in a wind tunnel of approximately 21 m total length. The tests distances between injection and integration device considered were: X/Dh = 22; X/Dh = 4; X/Dh 2; and X/Dh = 1. For very short distances of X/Dh = 2 and X/Dh = 1, semi-empirical expressions were needed. A good reproducibility of airflow rate values was obtained. These preliminary tests showed that the practical implementation of tracer gas techniques in HVAC systems for measuring airflow rates with a very short mixing distance is possible with the devices developed. (author)

  14. Atmospheric Gas Tracers in Groundwater: Theory, Sampling. Measurement and Interpretation

    International Nuclear Information System (INIS)

    Bayari, C.S.

    2002-01-01

    Some of the atmospheric gasses posses features that are sought in an environmental tracer of hydrogeologic interest. Among these, chlorofluorocarbons, sulfur hegzafluoride, carbon tetrachloride, methyl chloroform, krypton-85 etc. have found increasing use in groundwater age dating studies during the last ten years. This paper explains the theory of their use as tracer and discusses the major concerns as related to their sampling and analyses. Factors affecting their applicability and the approach to interpret tracer gas data is briefly outlined

  15. MRI findings and correlative study of MRI and visual evoked potentials in optic neuritis

    International Nuclear Information System (INIS)

    Yan Fei; Li Jing; Wang Zhenchang; Liu Shoubin; Zhang Xiaojun

    2008-01-01

    Objective: To investigate the effective MRI sequences and describe the correlation between MRI and visual evoked potential (VEP) in diagnosing optic neuritis. Methods: One hundred and fifty-four eyes with visual impairment of 98 patients with diagnoses of optic neuritis, papillitis, multiple sclerosis and Devic's disease underwent MRI and VEP examination. The MRI findings were analyzed and correlated with VEP results and clinical presentation by using X 2 test, wilco xon test and Kappa test. Results Out of the 154 sick eyes, 56 eyes presented thickened optic nerves, 76 eyes had normal diameter of the optic nerve, and 22 eyes had thin optic nerves. A total of 132 optic nerves showed abnormally high signal in STIR sequences, including involvement of intraocular segment in 7, intraorbital segment in 1.35, intracanalicular segment in 109, intracranial segment in 97, optic chiasm in 56, and optic tract in 23. A total of 54 patients underwent postcontrast MRI. Seventy-four optic nerves of 87 eyes showed enhancement. Among the 196 eyes of 98 patients, 132 eyes presented visual impairment and simultaneous abnormal MR signal of the optic nerve, and 26 eyes had both normal vision and normal MR signal of optic nerve. The consistency of MRI findings and vision status was 80. 61% (Kappa 0.453,P 1 -weighted MR sequence combined with fat- suppression are helpful in diagnosis of optic neuritis. VEP is helpful in diagnosing optic neuritis and in finding subclinical visual problem. The MRI combined with VEP could improve the diagnostic accuracy of optic neuritis. (authors)

  16. Tracers vs. trajectories in a coastal region

    Science.gov (United States)

    Engqvist, A.; Döös, K.

    2008-12-01

    Two different methods of estimating the water exchange through a Baltic coastal region have been used, consisting of particle trajectories and passive tracers. Water is traced from and to a small discharge region near the coast. The discharge material in this region is treated as zero dimensional particles or tracers with neutral buoyancy. The real discharge material could be a leakage of radio-nuclides through the sea floor from an underground repository of nuclear waste. Water exchange rates between the discharge region and the model domain are estimated using both forward and backward trajectories as well as passive tracers. The Lagrangian trajectories can account for the time evolution of the water exchange while the tracers give one average age per model grid box. Water exchange times such as residence time, age and transient times have been calculated with trajectories but only the average age (AvA) for tracers. The trajectory calculations provide a more detailed time evolution than the tracers. On the other hand the tracers are integrated "on-line" simultaneously in the sea circulation model with the same time step while the Lagrangian trajectories are integrated "off-line" from the stored model velocities with its inherent temporal resolution, presently one hour. The sub-grid turbulence is parameterised as a Laplacian diffusion for the passive tracers and with an extra stochastic velocity for trajectories. The importance of the parameterised sub-grid turbulence for the trajectories is estimated to give an extra diffusion of the same order as the Laplacian diffusion by comparing the Lagrangian dispersions with and without parameterisation. The results of the different methods are similar but depend on the chosen diffusivity coefficient with a slightly higher correlation between trajectories and tracers when integrated with a lower diffusivity coefficient.

  17. Application of tracer gas studies in the optimal design of soil vapor extraction systems

    International Nuclear Information System (INIS)

    Marley, M.C.; Cody, R.J.; Polonsky, J.D.; Woodward, D.D.; Buterbaugh, G.J.

    1992-01-01

    In the design of an optimal, cost effective vapor extraction system (VE) for the remediation of volatile organic compounds (VOCs), it is necessary to account for heterogeneities in the vadose zone. In some cases, such as those found in relatively homogeneous sands, heterogeneities can be neglected as induced air flow through the subsurface can be considered uniform. The subsurface conditions encountered at many sites (soil/bedrock interfaces, fractured bedrock) will result in preferential subsurface-air flow pathways during the operation of the VES. The use of analytical and numerical compressible fluid flow models calibrated and verified from parameter evaluation tests can be utilized to determine vadose zone permeability tensors in heterogeneous stratifications and can be used to project optimal, full scale VES performance. Model-derived estimations of the effect of uniform and/or preferential air flow pathways on subsurface induced air flow velocities can be enhanced, confirmed utilizing tracer gas studies. A vadose zone tracer gas study entails the injection of an easily detected, preferably inert gas into differing locations within the vadose zone at distances away from the VES extraction well. The VES extraction well is monitored for the detection of the gas. This is an effective field methodology to qualify and quantify the subsurface air flow pathways. It is imperative to gain an understanding of the dynamics of the air flow in the soils and lithologies of each individual site, and design quick and effective methodologies for the characterization of the subsurface to streamline remediation costs and system operations. This paper focuses on the use of compressible fluid flow models and tracer gas studies in the enhancement of the design of vapor extraction systems

  18. Dynamic study of an anaerobic reactor in pilot plant scale using radioactive tracer

    International Nuclear Information System (INIS)

    Pinto, A.M.F.; Moreira, R.M.; Chernicharo, C.A.L.

    1995-01-01

    The use of flow traces is a common practice in hydrodynamic studies. However chemical tracers have some shortcomings, such as the need of sampling, analysis and possible interferences with the delicate biological processes taking place within the reactor. Thus a radiotracer, Br 82 has been chosen for this purpose. The advantages of this radioisotope are its energetic gamma emission which can be easily detected outside the reactor walls, its solubility and lack of adsorption, besides having a convenient half-life and being easily produced is small nuclear reactors. The tracer responses to instantaneous injections at the reactor entrance were used to determine the resistance time and the mixing patterns of the reactors. The normalized residence time distributions were fitted to mathematical models by a least-squares subroutine. The axial dispersion model and the tanks-in-series model have been used, thus allowing the determination of the dispersion coefficient and the Peclet Number. (author). 5 refs, 4 figs, 1 tab

  19. Using biofuel tracers to study alternative combustion regimes

    International Nuclear Information System (INIS)

    Mack, J.H.; Flowers, D.L.; Buchholz, B.A.; Dibble, R.W.

    2007-01-01

    Interest in the use of alternative fuels and engines is increasing as the price of petroleum climbs. The inherently higher efficiency of Diesel engines has led to increased adoption of Diesels in Europe, capturing approximately 40% of the new passenger car market. Unfortunately, lower CO 2 emissions are countered with higher nitrogen oxides (NO x ) and particulate matter (PM) emissions and higher noise. Adding oxygenated compounds to the fuel helps reduce PM emissions. However, relying on fuel alone to reduce PM is unrealistic due to economic constraints and difficult due to the emerging PM standards. Keeping peak combustion temperature below 1700 K inhibits NO x formation. Altering the combustion regime to burn at temperatures below the NO x threshold and accept a wide variety of fuels seems like a promising alternative for future engines. Homogeneous charge compression ignition (HCCI) is a possible solution. Fuel and air are well mixed prior to intake into a cylinder (homogeneous charge) and ignition occurs by compression of the fuel-air mixture by the piston. HCCI is rapid and relatively cool, producing little NO x and PM. Unfortunately, it is hard to control since HCCI is initiated by temperature and pressure instead of a spark or direct fuel injection. We investigate biofuel HCCI combustion, and use intrinsically labeled biofuels as tracers of HCCI combustion. Data from tracer experiments are used to improve our combustion modeling

  20. Cortical control of gait in healthy humans: an fMRI study

    International Nuclear Information System (INIS)

    ChiHong, Wang; YauYau, Wai; BoCheng, Kuo; Yei-Yu, Yeh; JiunJie Wang

    2008-01-01

    This study examined the cortical control of gait in healthy humans using functional magnetic resonance imaging (fMRI). Two block-designed fMRI sessions were conducted during motor imagery of a locomotor-related task. Subjects watched a video clip that showed an actor standing and walking in an egocentric perspective. In a control session, additional fMRI images were collected when participants observed a video clip of the clutch movement of a right hand. In keeping with previous studies using SPECT and NIRS, we detected activation in many motor-related areas including supplementary motor area, bilateral precentral gyrus, left dorsal premotor cortex, and cingulate motor area. Smaller additional activations were observed in the bilateral precuneus, left thalamus, and part of right putamen. Based on these findings, we propose a novel paradigm to study the cortical control of gait in healthy humans using fMRI. Specifically, the task used in this study - involving both mirror neurons and mental imagery - provides a new feasible model to be used in functional neuroimaging studies in this area of research. (author)

  1. An fMRI study

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Biosciences; Volume 38; Issue 5 ... Alcoholism; brain; fMRI; language processing; lexical; semantic judgment ... alcohol dependence is associated with neurocognitive deficits in tasks requiring memory, perceptual ...

  2. Quantifying solute transport processes: are chemically "conservative" tracers electrically conservative?

    Science.gov (United States)

    Singha, Kamini; Li, Li; Day-Lewis, Frederick D.; Regberg, Aaron B.

    2012-01-01

    The concept of a nonreactive or conservative tracer, commonly invoked in investigations of solute transport, requires additional study in the context of electrical geophysical monitoring. Tracers that are commonly considered conservative may undergo reactive processes, such as ion exchange, thus changing the aqueous composition of the system. As a result, the measured electrical conductivity may reflect not only solute transport but also reactive processes. We have evaluated the impacts of ion exchange reactions, rate-limited mass transfer, and surface conduction on quantifying tracer mass, mean arrival time, and temporal variance in laboratory-scale column experiments. Numerical examples showed that (1) ion exchange can lead to resistivity-estimated tracer mass, velocity, and dispersivity that may be inaccurate; (2) mass transfer leads to an overestimate in the mobile tracer mass and an underestimate in velocity when using electrical methods; and (3) surface conductance does not notably affect estimated moments when high-concentration tracers are used, although this phenomenon may be important at low concentrations or in sediments with high and/or spatially variable cation-exchange capacity. In all cases, colocated groundwater concentration measurements are of high importance for interpreting geophysical data with respect to the controlling transport processes of interest.

  3. Comparative studies of MRI and operative findings in rotator cuff tear

    International Nuclear Information System (INIS)

    Yamakawa, Seigo; Ichikawa, Norikazu; Itadera, Eichi; Hashizume, Hiroyuki; Inoue, Hajime

    2001-01-01

    A prospective study was performed to determine the accuracy of magnetic resonance imaging (MRI) compared with operative findings in the evaluation of patients associated with rotator cuff tears. Fifty-four of 60 shoulders (58 patients) examined by MRI were confirmed as full-thickness tears and 6 as partial-thickness tears at the time of surgery. The oblique coronal, oblique sagittal, and axial planes of T2-weighted images with the 0.5 tesla MRI system were obtained preoperatively and compared with operative findings. MRI correctly identified 46 of 54 full-thickness rotator cuff tears and 5 of 6 partial-thickness tears. A comparison of MRI and operative findings in full-thickness cuff tears showed a sensitivity of 85%, a specificity of 83%, and a positive prospective value (PPV) of 99%. A comparison of partial-thickness tears showed a sensitivity of 83%, a specificity of 85%, and PPV of 39%. Linear regression analysis showed an excellent correlation between the MRI assessment and measurement at the time of surgery (r=0.90, P<0.01). MRI was useful in evaluating large and medium-sized rotator cuff tears, but less useful in distinguishing small full-thickness tears from partial-thickness tears. (author)

  4. The comparative study of CT and MRI on femoral head necrosis

    International Nuclear Information System (INIS)

    Lin Yunliang; Liu Xianghua; Wu Shiqiang; Zeng Kangnian

    2008-01-01

    Objective: To compare the imaging features of CT and MRI in the femoral head necrosis as well as their pathological basis. Methods: 18 cases (30 hips) with femoral head necrosis proved by follow-up studies or pathology were analyzed, including 3 cases of pathological data. Results: The blurred high-density sclerotic line on CT in 28 hips were corresponded to 'line-like signs' on MRI, whereas, the other two hips without blurred high-density sclerosis line appeared 'line-like signs' on MRI. The normal area surrounded by the high-density line on CT in 26 hips were corresponded to fat-like signal area in 12 hips and mixed signal area in 14 hips on MRI. The other 4 hips with blurred bony trabeculum surrounded by the high-density line on CT showed mixed signal intensity on MRI. Conclusion: The high-density sclerotic line on CT corresponds to 'line-like sign' on MRI, which was considered as reactive interface between necrotic and viable region, was a specific signs to diagnose FHN. Compared with CT, MRI can accurately reflect pathological process during different repaired stages. (authors)

  5. Diffusing passive tracers in random incompressible flows: Statistical topography aspects

    International Nuclear Information System (INIS)

    Klyatskin, V.I.; Woyczynski, W.A.; Gurarie, D.

    1996-01-01

    The paper studies statistical characteristics of the passive tracer concentrations and of its spatial gradient, in random incompressible velocity fields from the viewpoint of statistical topography. The statistics of interest include mean values, probability distributions, as well as various functionals characterizing topographic features of tracers. The functional approach is used. We consider the influence of the mean flow (the linear shear flow) and the molecular diffusion coefficient on the statistics of the tracer. Most of our analysis is carried out in the framework of the delta-correlated (in time) approximation and conditions for its applicability are established. But we also consider the diffusion approximation scheme for finite correlation radius. The latter is applied to a diffusing passive tracer that undergoes sedimentation in a random velocity field

  6. Stable isotope tracers and exercise physiology: past, present and future.

    Science.gov (United States)

    Wilkinson, Daniel J; Brook, Matthew S; Smith, Kenneth; Atherton, Philip J

    2017-05-01

    Stable isotope tracers have been invaluable assets in physiological research for over 80 years. The application of substrate-specific stable isotope tracers has permitted exquisite insight into amino acid, fatty-acid and carbohydrate metabolic regulation (i.e. incorporation, flux, and oxidation, in a tissue-specific and whole-body fashion) in health, disease and response to acute and chronic exercise. Yet, despite many breakthroughs, there are limitations to 'substrate-specific' stable isotope tracers, which limit physiological insight, e.g. the need for intravenous infusions and restriction to short-term studies (hours) in controlled laboratory settings. In recent years significant interest has developed in alternative stable isotope tracer techniques that overcome these limitations, in particular deuterium oxide (D 2 O or heavy water). The unique properties of this tracer mean that through oral administration, the turnover and flux through a number of different substrates (muscle proteins, lipids, glucose, DNA (satellite cells)) can be monitored simultaneously and flexibly (hours/weeks/months) without the need for restrictive experimental control. This makes it uniquely suited for the study of 'real world' human exercise physiology (amongst many other applications). Moreover, using D 2 O permits evaluation of turnover of plasma and muscle proteins (e.g. dynamic proteomics) in addition to metabolomics (e.g. fluxomics) to seek molecular underpinnings, e.g. of exercise adaptation. Here, we provide insight into the role of stable isotope tracers, from substrate-specific to novel D 2 O approaches, in facilitating our understanding of metabolism. Further novel potential applications of stable isotope tracers are also discussed in the context of integration with the snowballing field of 'omic' technologies. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  7. Evaluating glymphatic pathway function utilizing clinically relevant intrathecal infusion of CSF tracer.

    Science.gov (United States)

    Yang, Lijun; Kress, Benjamin T; Weber, Harris J; Thiyagarajan, Meenakshisundaram; Wang, Baozhi; Deane, Rashid; Benveniste, Helene; Iliff, Jeffrey J; Nedergaard, Maiken

    2013-05-01

    Neurodegenerative diseases such as Alzheimer's are associated with the aggregation of endogenous peptides and proteins that contribute to neuronal dysfunction and loss. The glymphatic system, a brain-wide perivascular pathway along which cerebrospinal fluid (CSF) and interstitial fluid (ISF) rapidly exchange, has recently been identified as a key contributor to the clearance of interstitial solutes from the brain, including amyloid β. These findings suggest that measuring changes in glymphatic pathway function may be an important prognostic for evaluating neurodegenerative disease susceptibility or progression. However, no clinically acceptable approach to evaluate glymphatic pathway function in humans has yet been developed. Time-sequenced ex vivo fluorescence imaging of coronal rat and mouse brain slices was performed at 30-180 min following intrathecal infusion of CSF tracer (Texas Red- dextran-3, MW 3 kD; FITC- dextran-500, MW 500 kD) into the cisterna magna or lumbar spine. Tracer influx into different brain regions (cortex, white matter, subcortical structures, and hippocampus) in rat was quantified to map the movement of CSF tracer following infusion along both routes, and to determine whether glymphatic pathway function could be evaluated after lumbar intrathecal infusion. Following lumbar intrathecal infusions, small molecular weight TR-d3 entered the brain along perivascular pathways and exchanged broadly with the brain ISF, consistent with the initial characterization of the glymphatic pathway in mice. Large molecular weight FITC-d500 remained confined to the perivascular spaces. Lumbar intrathecal infusions exhibited a reduced and delayed peak parenchymal fluorescence intensity compared to intracisternal infusions. Lumbar intrathecal contrast delivery is a clinically useful approach that could be used in conjunction with dynamic contrast enhanced MRI nuclear imaging to assess glymphatic pathway function in humans.

  8. Radiography students' clinical placement experiences in MRI: A phenomenological study

    International Nuclear Information System (INIS)

    Portanier Mifsud, Claude; Castillo, Joseph; Portelli, Jonathan Loui

    2015-01-01

    Purpose: The purpose of this study was to gain an insight into radiography students' clinical practice experiences within an MRI unit of a large teaching hospital in Malta. The underlying objectives of the study were to identify and explore the descriptions and meanings of the MRI clinical experiences of students. Methods: Five students, independently undergoing their clinical placements in MRI were asked to write a diary about their daily experiences. Each student then participated in a follow up interview. Data analysis was based on Husserls' phenomenological approach. Results: Eight themes emerged from the data analysed. Students described their experience as one mainly based on observation, where, during their placements, they observed radiographers at work. In this respect, students described their experience as lacking ‘hands on practice’. Students indicated that they felt uncomfortable, unsupervised and unwelcome most of the time. They also expressed the need to feel useful and part of the MRI team during their placement and so they tried to help the team in areas such as patient screening. This helped them build confidence. Learning in MRI was specifically based on the university tasks prescribed and possibly there was no motivation to learn more. The students also described their experience as varied and different when compared to other placements. Conclusion: This study provides a rare insight into radiography students' placement experiences in MRI and should enable the supervising radiographer and educator to obtain a deeper appreciation of the clinical placement experience

  9. Key aspects of stratospheric tracer modeling using assimilated winds

    Directory of Open Access Journals (Sweden)

    B. Bregman

    2006-01-01

    Full Text Available This study describes key aspects of global chemistry-transport models and their impact on stratospheric tracer transport. We concentrate on global models that use assimilated winds from numerical weather predictions, but the results also apply to tracer transport in general circulation models. We examined grid resolution, numerical diffusion, air parcel dispersion, the wind or mass flux update frequency, and time interpolation. The evaluation is performed with assimilated meteorology from the "operational analyses or operational data" (OD from the European Centre for Medium-Range Weather Forecasts (ECMWF. We also show the effect of the mass flux update frequency using the ECMWF 40-year re-analyses (ERA40. We applied the three-dimensional chemistry-transport Tracer Model version 5 (TM5 and a trajectory model and performed several diagnoses focusing on different transport regimes. Covering different time and spatial scales, we examined (1 polar vortex dynamics during the Arctic winter, (2 the large-scale stratospheric meridional circulation, and (3 air parcel dispersion in the tropical lower stratosphere. Tracer distributions inside the Arctic polar vortex show considerably worse agreement with observations when the model grid resolution in the polar region is reduced to avoid numerical instability. The results are sensitive to the diffusivity of the advection. Nevertheless, the use of a computational cheaper but diffusive advection scheme is feasible for tracer transport when the horizontal grid resolution is equal or smaller than 1 degree. The use of time interpolated winds improves the tracer distributions, particularly in the middle and upper stratosphere. Considerable improvement is found both in the large-scale tracer distribution and in the polar regions when the update frequency of the assimilated winds is increased from 6 to 3 h. It considerably reduces the vertical dispersion of air parcels in the tropical lower stratosphere. Strong

  10. Using Tracer Technology to Characterize Contaminated Pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Maresca, Joseph, W., Jr., Ph.D.; Bratton, Wesley, L., Ph.D., P.E.; Dickerson, Wilhelmina; Hales, Rochelle

    2005-12-30

    The Pipeline Characterization Using Tracers (PCUT) technique uses conservative and partitioning, reactive or other interactive tracers to remotely determine the amount of contaminant within a run of piping or ductwork. The PCUT system was motivated by a method that has been successfully used to characterize subsurface soil contaminants and is similar in operation to that of a gas chromatography column. By injecting a ?slug? of both conservative and partitioning tracers at one end (or section) of the piping and measuring the time history of the concentration of the tracers at the other end (or another section) of the pipe, the presence, location, and amount of contaminant within the pipe or duct can be determined. The tracers are transported along the pipe or duct by a gas flow field, typically air or nitrogen, which has a velocity that is slow enough so that the partitioning tracer has time to interact with the contaminant before the tracer slug completely passes over the contaminate region. PCUT not only identifies the presence of contamination, it also can locate the contamination along the pipeline and quantify the amount of residual. PCUT can be used in support of deactivation and decommissioning (D&D) of piping and ducts that may have been contaminated with hazardous chemicals such as chlorinated solvents, petroleum products, radioactive materials, or heavy metals, such as mercury.

  11. Case study: evaluation of the performance of water treatment units by the use of tracer techniques

    International Nuclear Information System (INIS)

    Sebastian, C.; Maghella, G.; Mamani, E.

    2000-12-01

    Very often, water treatment systems do not reach the expected performance due to disturbances of hydraulic order, which cause malfunctioning in the flow through such systems. Tracer techniques have proved to be very useful to obtain information on the system or a part of it, by means of observation of the released tracer or observation of the released tracer during its progress into the system or at the output of the same. This paper is a report of the behavior of a set of both sand settlement unit and hydraulic flocculators in a potable water plant, through the analysis of radiotracers response curves or residence time distribution curves. The tracers released into the system consists in an aqueous solution of Iodine-131 with very low activity, in order to get a dynamic behave similar to the one of the fluid under investigation

  12. New developments in the use of stable activable tracers in environmental science

    International Nuclear Information System (INIS)

    Loveland, W.; Keasler, K.; Ghannam, L.; Borovik, A.

    1980-01-01

    Recent developments in the use of stable activable tracers (SATs) in environmental science are reported. (A stable activable tracer is a stable material injected into a system under study and whose concentration is measured by post-sampling activation analysis.) The activable nuclear parts of the tracers studied have been rare earth nuclides with short-lived activation products or Cu. To trace the fate of fluid-bound pollutants (and/or water masses) in marine waters, we have used anionic DTPA complexes of the rare earths. These tracers were shown to be stable (80 to 90% nondissociated) in extensive laboratory tests involving solutions of the tracer in estuarine water including large amounts of marine sediments. Results of a field study in which the flushing time and other hydrological characteristics of an estuarine marina were measured by simultaneously using a fluorescent dye and a SAT are presented. To trace the path of potentially toxic organic molecules, three stable activable tracers, dysprosium(III)-trisacetylacetonate DY(acac) 3 3H 2 O), dysprosium(III)-trisdibenzoylmethane (DY(dbm) 3 H 2 O and copper oxinate Cu (C 9 H 6 ON) 2 were synthesized. Their octanol/water partition coefficients and their solubility in water were measured and used to correlate the tracer species and its biological activity with that of known toxic materials. In a project to demonstrate the simple use of SATs to trace the origin of common insecticides and herbicides, seven common insecticides and herbicides were marked with anionic rare earth DTPA complexes and shown to be detectable at dilutions of 1 part in 10 12 . Two arsenical herbicides were chosen for further study and the tracer/herbicide ratio was shown to remain constant in samples of herbicide material collected on plant surfaces and runoff waters in the environment for long periods

  13. MRI study in spondyloepiphyseal dysplasia tarda with progressive arthropathy

    International Nuclear Information System (INIS)

    Tan Lihua; Liao Eryuan; Xiao Enhua; Ma Cong; Du Wanping; Li Jian

    2005-01-01

    Objective: To study the MRI features and the cartilaginous pathology of the spondyloepiphyseal dysplasia tarda with progressive arthropathy (SEDT-PA). Methods: MRI of spine, bilateral hips, and knees was taken in 2 cases with clinically and radiographically proven SEDT-PA, who were sister and brother and whose parents were healthy and not inbreeding. The sister's femoral heads were resected bilaterally and the tissues were used for pathological study. Results: MRI showed that the kyphosis and lateroflexion of the spine, and the degenerative signs of the intervertebral discs became more evident along with the growth of the patients. The anterior annular secondary ossification centers of cartilaginous epiphyses of some vertebral bodies didn't appear. So the affected vertebral bodies were like 'inverted vase' or the end p late like 'steps'. Bilateral acetabular cartilage and medial epicondylian cartilaginous epiphyses of the femurs in the young brother showed regional high signal intensity on coronal fat-saturated proton density weighted MR images and degenerative signs on the elder sister. The regional hyperplasia and hypogenesis of the femoral head cartilage could be seen by microscope. Conclusion: There are characteristic features on MRI in SEDT-PA and this is due to the regional hyperplasia and hypogenesis of the cartilage pathologically. (authors)

  14. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo (Tokyo Medical Coll. (Japan))

    1990-06-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: (1) easy detection of lesions with undetectable damages on CT, (2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and (3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author).

  15. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo

    1990-01-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: 1) easy detection of lesions with undetectable damages on CT, 2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and 3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author)

  16. Development and evaluation of a tracer-injection hydrothermal technique for studies of waste package interactions

    International Nuclear Information System (INIS)

    Jones, T.E.; Coles, D.G.; Britton, R.C.; Burnell, J.R.

    1986-11-01

    A tracer-injection system has been developed for use in characterizing reactions of waste package materials under hydrothermal conditions. High-pressure liquid chromatographic instrumentation has been coupled with Dickson-type rocking autoclaves to allow injection of selected components into the hydrothermal fluid while maintaining run temperature and pressure. Hydrothermal experiments conducted using this system included the interactions of depleted uranium oxide and Zircaloy-4 metal alloy discs with trace levels of 99 Tc and non-radioactive Cs and I in a simulated groundwater matrix. After waste-package components and simulated waste forms were pre-conditioned in the autoclave systems (usually 4 to 6 weeks), known quantities of tracer-doped fluids were injected into the autoclaves' gold reaction bag at run conditions. Time-sequenced sampling of the hydrothermal fluid providing kinetic data on the reactions of tracers with waste package materials. The injection system facilitates the design of experiments that will better define ''steady-state'' fluid compositions in hydrothermal reactions. The injection system will also allow for the formation of tracer-bearing solid phases in detectable quantities

  17. Development and Validation of Water Vapor Tracers as Diagnostics for the Atmospheric Hydrologic Cycle

    Science.gov (United States)

    Bosilovich, Michael G.; Schubert, Siegfried D.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    Understanding of the local and remote sources of water vapor can be a valuable diagnostic in understanding the regional atmospheric hydrologic cycle. In the present study, we have implemented passive tracers as prognostic variables to follow water vapor evaporated in predetermined regions until the water tracer precipitates. The formulation of the sources and sinks of tracer water is generally proportional to the prognostic water vapor variable. Because all water has been accounted for in tracers, the water vapor variable provides the validation of the tracer water and the formulation of the sources and sinks. The tracers have been implemented in a GEOS General Circulation Model (GCM) simulation consisting of several summer periods to determine the source regions of precipitation for the United States and India. The recycling of water and interannual variability of the sources of water will be examined. Potential uses in GCM sensitivity studies, predictability studies and data assimilation will be discussed.

  18. A study comparing MRI with clinical examinations on wrists with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Wang Jun; Niu Jinliang; Xie Weina; Song Zhizhen; Zheng Jie; Ma Qiang

    2004-01-01

    Objective: To study the appearances of rheumatoid arthritis (RA) on MRI, and compare MRI with clinical examinations on wrists with RA. Methods: Fifty patients, fulfilled 1987 American Rheumatism Association (ARA) revised criteria, and 10 age-matched healthy controls entered the study. T 1 -weighted spin echo, short time inversion recovery (STIR) of both wrists, gadolinium contrast material-enhanced sequences of dominant wrists were performed in the coronal planes. MRl, plain wrist radiographs, clinical date, including swollen joint, patient global assessment (AIMS), and laboratory examinations including ESR, RF, APF, and AKA were obtained at the same time. Functional disability was assessed using the Health Assessment Questionnaire Disability Score. Results: In 50 patients, all had pannus on MRI of wrists, 38 patients had enhanced signal intensity for pannus, 21 patients had bone marrow edema, 37 patients had joint effusion, and 37 patients had bone erosions. There were significant difference in the ESR, HAQ, AIMS as well as swollen joint count between patients with bone marrow edema and patients without bone marrow edema (P 2 =5.06, P=0.025; χ 2 =5.59, P=0.018). Number of patients with MRI erosion of wrists was associated with the number of patients without MRI bone marrow edema of wrists (χ 2 =5.11, P=0.024). Conclusion: MRI can find the appearances of wrists with RA. Comparing MRI with clinical examinations on wrists with RA, authors can assess and evaluate the role of MRI on RA

  19. Development of activable tracers for application in secondary recovering in petroleum reservoirs

    International Nuclear Information System (INIS)

    Martins, Polyana Fabricia Fernandes; Moreira, Rubens Martins . Servico de Meio Ambiente e Tecnicas Nucleares.

    2007-01-01

    Nuclear methods are instrumental in describing detailed flow patterns and other features of oil reservoirs that are unattainable to other methods. Tracer studies in oil fields are performed in a net of injection and producing wells. Thus, the use of only one tracer species would not discriminate the contributions of distinct injection wells to the output of a given production well. Hence, a multi-tracer experiment is required, and the use of activable tracers, capable of being measured by neutron activation analysis (NAA) is here proposed. As additional tracer choices lanthanum (La) and europium (Eu) were chosen from the rare earth series due to their large neutron cross sections and general availability. In order to decrease losses to the oil phase and the retardation of the tracer relatively to the aqueous phase, these elements were complexed with organic chelating ligands: the polyaminocarboxylic acids EDTA, DTPA and DOTA. Infrared spectrometry was used to check complexation. In order to check the partition of the tracer between the aqueous and organic phases, tests were carried stirring the two phases together and measuring the tracer concentrations in the aqueous phase; the partition coefficient (Kao) was then calculated for all the combinations of the two lanthanides and the three ligands. Tests in which the tracer was continuously pumped through reservoir rock samples were also carried out using tritiated water as a reference tracer and the complexed lanthanides. (author)

  20. Mineral imbalances in farm animals and their study and diagnosis with isotopic tracers

    International Nuclear Information System (INIS)

    Underwood, E.J.

    1976-01-01

    Twenty-two mineral elements are known to be essential for animal life. These are calcium, phosphorus, sulphur, potassium, sodium, chlorine, magnesium, iron, iodine, copper, manganese, zinc, cobalt, molybdenum, selenium, chromium, tin, vanadium, fluorine, silicon, nickel and arsenic. Naturally occurring and man-made dietary imbalances of many of these elements and their interactions with other minerals are described and their functions and requirements by farm animals are outlined. The nature and importance of metabolic interactions among the mineral elements are discussed and the important concept stressed that there is no single minimum requirement or safe tolerance of a particular mineral, but a series of such minimum requirements and safe tolerances depending on the extent to which other minerals with which it interacts is present or absent from the diet. Radioactive tracer elements are shown to be of great value in the determination of mineral nutrient availability to the animal and for following mineral metabolic movements in the body. They are also shown to have considerable potential for the diagnosis of mineral imbalances. Various in vivo and in vitro techniques involving both radioactive and stable tracers developed for the early diagnosis of mineral deficiencies are described and the strengths and weaknesses of such techniques, in comparison with standard biochemical tests, are discussed. The need for further critical studies with isotopic tracers in the detection and diagnosis of mineral imbalances is emphasized. The main types of biochemical criteria used in the diagnosis of mineral deficiencies and excesses are given, with appropriate examples of their use. (author)

  1. Biodistribution of [11C] methylaminoisobutyric acid, a tracer for PET studies on system A amino acid transport in vivo

    International Nuclear Information System (INIS)

    Sutinen, E.; Jyrkkioe, S.; Groenroos, T.; Haaparanta, M.; Lehikoinen, P.; Naagren, K.

    2001-01-01

    [N-methyl- 11 C]α-Methylaminoisobutyric acid ( 11 C-MeAIB) is a potentially useful tracer for positron emission tomography (PET) studies on hormonally regulated system A amino acid transport. 11 C-MeAIB is a metabolically stable amino acid analogue specific for system A amino acid transport. We evaluated the biodistribution of 11 C-MeAIB in rats and humans to estimate the usefulness of the tracer for in vivo human PET studies, for example, on regulation of system A amino acid transport and on tumour imaging. Healthy Sprague-Dawley rats (n=14) were killed 5, 20, 40 or 60 min after the injection of 11 C-MeAIB, and the tissue samples were weighed and counted for 11 C radioactivity. Ten lymphoma patients with relatively limited tumour burden underwent whole-body (WB) PET imaging with 11 C-MeAIB. In addition, three other patients had dynamic PET scanning of the head and neck area, and the tracer uptake was quantitated by calculating the kinetic influx constants (K i values) for the tracer. In animal studies, the highest activity was detected in the kidney, pancreas, adrenal gland and intestines. In humans, the highest activity was found in the salivary glands, and after that in the kidney and pancreas, similar to the results in animal studies. Rapid uptake was also detected in the skeletal muscle. In the graphical analysis, linear plots were obtained, and the mean fractional tracer uptake values (K i ) of the parotid glands (n=3) and cervical muscles (n=3) were 0.039±0.008 min -1 and 0.013±0.006 min -1 , respectively. The K i value of the tumour (n=1) was 0.064 min -1 . Higher uptake of 11 C-MeAIB into the tumour tissue was encountered. These results encourage further 11 C-MeAIB PET studies in humans on the physiology and pathology of system A amino acid transport and on tumour detection. (orig.)

  2. Analysis of tracer transit in rat brain after carotid artery and femoral vein administrations using linear system theory.

    Science.gov (United States)

    Rudin, M; Beckmann, N; Sauter, A

    1997-01-01

    Determination of tissue perfusion rates by MRI bolus tracking methods relies on the central volume principle which states that tissue blood flow is given by the tissue blood volume divided by the mean tracer transit time (MTT). Accurate determination of the MTT requires knowledge of the arterial input function which in MRI experiments is usually not known, especially when using small animals. The problem of unknown arterial input can be circumvented in animal experiments by directly injecting the contrast agent into a feeding artery of the tissue of interest. In the present article the passage of magnetite nanoparticles through the rat cerebral cortex is analyzed after injection into the internal carotid artery. The results are discussed in the framework of linear system theory using a one-compartment model for brain tissue and by using the well characterized gamma-variate function to describe the tissue concentration profile of the contrast agent. The results obtained from the intra-arterial tracer administration experiments are then compared with the commonly used intra-venous injection of the contrast agent in order to estimate the contribution of the peripheral circulation to the MTT values in the latter case. The experiments were analyzed using a two-compartment model and the gamma-variate function. As an application perfusion rates in normal and ischemic cerebral cortex of hypertensive rats were estimated in a model of focal cerebral ischemia. The results indicate that peripheral circulation has a significant influence on the MTT values and thus on the perfusion rates, which cannot be neglected.

  3. Renal and perirenal space involvement in acute pancreatitis: An MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xing Hui, E-mail: lixinghui1005@126.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Zhang, Xiao Ming, E-mail: cjr.zhxm@vip.163.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Ji, Yi Fan, E-mail: 526504036@qq.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Jing, Zong Lin, E-mail: jzl325@163.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Huang, Xiao Hua, E-mail: nc_hxh1966@yahoo.com.cn [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Yang, Lin, E-mail: linyangmd@163.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China); Zhai, Zhao Hua, E-mail: zhaizhaohuada@163.com [Sichuan Key Laboratory of Medical Imaging, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000 (China)

    2012-08-15

    Objectives: To study the prevalence and characteristics of renal and perirenal space involvement and its relation to the severity of acute pancreatitis (AP) using MRI. Methods: 115 patients with AP who underwent MRI with the clinical kidney function test were retrospectively analyzed in this study. MRI sequences included conventional and diffusion weighted imaging (DWI) sequences. The renal and perirenal space involvement in AP was noted on MRI. The renal apparent diffusion coefficient (ADC) on DWI was measured for each kidney. The severity of AP on MRI was graded using MR severity index (MRSI). The relationships among the renal and perirenal space involvement on MRI, the renal ADC, MRSI and the results of the kidney function test were analyzed. Results: In the 115 patients with AP, the renal and perirenal space abnormalities detected included renal parenchymal abnormalities (0.8%), abnormalities of the renal collecting system (2.6%), renal vascular abnormalities (1.7%), thickened renal fascia (99%), perirenal stranding (62%) and perirenal fluid collection (40%). The prevalence of perirenal space abnormalities was correlated with the severity of AP based on MRSI (P < 0.05). The renal ADC values were lower in patients with abnormal kidney function than in those without kidney injury (P < 0.05). The prevalence of kidney function abnormalities was 9.4%, 32% and 100% in mild, moderate, and severe AP cases, respectively (P = 0.00). Conclusion: Perirenal space involvement is much more than renal parenchymal involvement in AP. The prevalence of perirenal space involvement in AP on MRI has a positive correlation with the severity of AP according to MRSI.

  4. Renal and perirenal space involvement in acute pancreatitis: An MRI study

    International Nuclear Information System (INIS)

    Li, Xing Hui; Zhang, Xiao Ming; Ji, Yi Fan; Jing, Zong Lin; Huang, Xiao Hua; Yang, Lin; Zhai, Zhao Hua

    2012-01-01

    Objectives: To study the prevalence and characteristics of renal and perirenal space involvement and its relation to the severity of acute pancreatitis (AP) using MRI. Methods: 115 patients with AP who underwent MRI with the clinical kidney function test were retrospectively analyzed in this study. MRI sequences included conventional and diffusion weighted imaging (DWI) sequences. The renal and perirenal space involvement in AP was noted on MRI. The renal apparent diffusion coefficient (ADC) on DWI was measured for each kidney. The severity of AP on MRI was graded using MR severity index (MRSI). The relationships among the renal and perirenal space involvement on MRI, the renal ADC, MRSI and the results of the kidney function test were analyzed. Results: In the 115 patients with AP, the renal and perirenal space abnormalities detected included renal parenchymal abnormalities (0.8%), abnormalities of the renal collecting system (2.6%), renal vascular abnormalities (1.7%), thickened renal fascia (99%), perirenal stranding (62%) and perirenal fluid collection (40%). The prevalence of perirenal space abnormalities was correlated with the severity of AP based on MRSI (P < 0.05). The renal ADC values were lower in patients with abnormal kidney function than in those without kidney injury (P < 0.05). The prevalence of kidney function abnormalities was 9.4%, 32% and 100% in mild, moderate, and severe AP cases, respectively (P = 0.00). Conclusion: Perirenal space involvement is much more than renal parenchymal involvement in AP. The prevalence of perirenal space involvement in AP on MRI has a positive correlation with the severity of AP according to MRSI.

  5. Toxicity of fluorescent tracers and their degradation byproducts

    Directory of Open Access Journals (Sweden)

    Philippe Gombert

    2017-01-01

    Full Text Available Tracer tests are frequently used to delineate catchment area of water supply springs in karstic zones. In the karstic chalk of Normandy, the main tracers used are fluorescent: uranine, sulforhodamine B, naphtionate, and Tinopal®. In this area, a statistical analysis shows that less than half of the injected tracers joins the monitored restitution points and enters the drinking water system where they undergo chlorination. Most of the injected tracers is absorbed in the rock matrix or is thrown out of the aquifer via karstic springs: then it can join superficial waters where it is degraded due to the sun and air action. The paper presents firstly the laboratory degradation of a first batch of fluorescent tracers in contact with chlorine, in order to simulate their passage through a water treatment system for human consumption. A second batch of the same tracers is subjected to agents of natural degradation: ultraviolet illumination, sunlight and air sparging. Most tracers is degraded, and toxicity and ecotoxicity tests (on rats, daphniae and algae are performed on degradation byproducts. These tests do not show any acute toxicity but a low to moderate ecotoxicity. In conclusion, the most used fluorescent tracers of the Normandy karstic chalk and their artificial and natural degradation byproducts do not exhibit significant toxicity to humans and the aquatic environment, at the concentrations generally noted at the restitution points.

  6. The European Tracer Experiment - experimental results and database

    International Nuclear Information System (INIS)

    Nodop, K.; Connolly, R.; Girardi, F.

    1997-01-01

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 hours after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. Typical background concentrations of the tracer used are around 5 to 7 fl/l in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/l. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport (LRT) models are assembled in the ETEX database. The ETEX database is accessible via the Internet

  7. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) PET/MRI in patients with head and neck cancer. This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4±13.4 years) with histologically proven head and neck tumors were enrolled.Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared. Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron

  8. Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study

    Science.gov (United States)

    Harris, Wendy; Yin, Fang-Fang; Wang, Chunhao; Zhang, You; Cai, Jing; Ren, Lei

    2018-01-01

    Purpose. To accelerate volumetric cine MRI (VC-MRI) using undersampled 2D-cine MRI to provide real-time 3D guidance for gating/target tracking in radiotherapy. Methods. 4D-MRI is acquired during patient simulation. One phase of the prior 4D-MRI is selected as the prior images, designated as MRIprior. The on-board VC-MRI at each time-step is considered a deformation of the MRIprior. The deformation field map is represented as a linear combination of the motion components extracted by principal component analysis from the prior 4D-MRI. The weighting coefficients of the motion components are solved by matching the corresponding 2D-slice of the VC-MRI with the on-board undersampled 2D-cine MRI acquired. Undersampled Cartesian and radial k-space acquisition strategies were investigated. The effects of k-space sampling percentage (SP) and distribution, tumor sizes and noise on the VC-MRI estimation were studied. The VC-MRI estimation was evaluated using XCAT simulation of lung cancer patients and data from liver cancer patients. Volume percent difference (VPD) and Center of Mass Shift (COMS) of the tumor volumes and tumor tracking errors were calculated. Results. For XCAT, VPD/COMS were 11.93  ±  2.37%/0.90  ±  0.27 mm and 11.53  ±  1.47%/0.85  ±  0.20 mm among all scenarios with Cartesian sampling (SP  =  10%) and radial sampling (21 spokes, SP  =  5.2%), respectively. When tumor size decreased, higher sampling rate achieved more accurate VC-MRI than lower sampling rate. VC-MRI was robust against noise levels up to SNR  =  20. For patient data, the tumor tracking errors in superior-inferior, anterior-posterior and lateral (LAT) directions were 0.46  ±  0.20 mm, 0.56  ±  0.17 mm and 0.23  ±  0.16 mm, respectively, for Cartesian-based sampling with SP  =  20% and 0.60  ±  0.19 mm, 0.56  ±  0.22 mm and 0.42  ±  0.15 mm, respectively, for

  9. Studies of radioisotope tracer technique and its applications to pesticide sciences in China

    International Nuclear Information System (INIS)

    Jia Minghong; Chen Qing; Zheng Ran

    1996-05-01

    The improper use of chemical pesticides has resulted in serious environmental problems and food pollutions, affecting the ecosystem balance and human being health. There are more and more scientists and research institutions being engaged in the area of radioisotope tracer techniques for pesticide sciences in China. So far, more than 80 labeled compounds, including insecticides, fungicides, acaricides, herbicides, metabolic intermediates, fertilizer and biological agents, etc. have been synthesized at the laboratory for application of isotopes in Institute for Application of Atomic Energy, Chinese Academy of Agricultural Sciences. Over past several years, the great achievements have been made in the researches of radioisotope tracer techniques and their applications to pesticide sciences in China, especially in the researches for isotopic labeling, residues, degradation and metabolism of pesticides in plant and animal, behavior and fate of pesticides in environment, and techniques for safe application of pesticide, and so on. The researches of radioisotope tracer techniques and their applications to pesticide sciences in China in the past years are briefly introduced. Some problems are put forward and the development in future is predicted. (1 tab.)

  10. [Drainage characteristic of the brain interstitial fluid detected by using fluorescence and magnetic tracer method].

    Science.gov (United States)

    Zhao, Y; Li, Y Q; Li, H Y; Li, Y L; Liu, L X; Yuan, L; Zhang, S J; Han, H B

    2017-04-18

    Compare the results of molecular diffusion and mass flow in the interstitial space(ISS) displayed by using optical and magnetic probes and study partitioned drainage of the brain interstitial fluid (ISF). In the study, 36 male SD rats were randomly divided into fluorescent inspection group (18), magnetic tracer group (18). Then they were divided equally into caudate nucleus (Cn), thalamus (T) and substantia nigra (Sn) subgroup, 6 rats in each subgroup. Referencing the brain stereotaxic atlas, the coronal globus pallidus as center level, Cn, T or Sn were acted as puncture positioning target. A 10 μL microsyringe was stereotaxically positioned and the lucifer yellow (LY) solution of 2 μL 10 mmol/L was infused into centric position. The coronary slices undergo cardiac perfusion and fix respectively in time point Cn 3 h, T 2 h and Sn 1 h. The rat brain was placed in rat stainless steel brain matrices and cut backward along visual intersection. The injection point of coronal slice as the center level, take 3 slices in front of the center level and 2 slices behind of it. 1 mm for each slice and 6 slices in total. Then slices were detected by laser scanning confocal microscope (LSCM). Simultaneous, in the same coordinate brain regions of another three groups, a gadolinium-diethylene triamine pentaacetic acidm (Gd-DTPA) solution of 2 μL 10 mmol/L was infused into different injection and detected by MRI tracer-based method. Then the Radiant can be used to measure distribution area of Gd-DTPA. LY and Gd-DTPA have different distribution regions in Cn, T and Sn. After LY and Gd-DTPA were introduced into the Cn subgroup 3 h, compare the 1 to 6 levels distribution area of LY and Gd-DTPA as follows: (10.95±4.27) mm 2 vs. (8.33±2.25) mm 2 , (18.16±4.74) mm 2 vs. (16.42±2.88) mm 2 , (24.57±3.65) mm 2 vs. (20.75±2.29) mm 2 , (34.81±3.32) mm 2 vs. (28.88±1.51) mm 2 , (30.53±3.12) mm 2 vs. (20.92±2.75) mm 2 , (12.15±4.92) mm 2 vs. (10.00±1.89) mm 2 . The statistical

  11. Slew-rate dependence of tracer magnetization response in magnetic particle imaging

    Science.gov (United States)

    Shah, Saqlain A.; Ferguson, R. M.; Krishnan, K. M.

    2014-10-01

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ0 excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude (Ho) and frequency (ω). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particle Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ0. For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate (ωHo) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.

  12. Anatomic MRI study of a small muscle: the masseter

    International Nuclear Information System (INIS)

    Dheyriat, A.; Lissac, M.; Sappey-Marinier, D.; Bonmartin, A.

    1997-01-01

    Magnetic resonance imaging (MRI) provides functional information in an anatomic presentation allowing to distinguish soft tissues with high sensitivity. The goal of this study was to investigate the normal anatomy of the major masticatory muscle, the masseter, both at rest or during contraction by using three dimensional (3D) MRI. Eighteen subjects aged from 19 to 28 years, all in good health, were studied. Several experiments were first realized on phantoms to test the 3D-MRI technique. After reconstruction and segmentation processing, 3D acquisition, enabled obtaining data on the masseter anatomy. The normal anatomical position of the masseter was reported to the skin plan as the mean internal distance (7.9±0.42 mm) and external distance (15.2±0.41 mm). While there was no difference between internal distance, for sex or side, the external distance was significantly (p = 0.02) shorter in male (7.7±0.5 mm) than in female (8.8±0.4 mm) for both sides. The mean volume for all subjects and both sides (20.3±1.1 cm 3 ) did not change significantly between rest and exercise. The masseter volume was significantly (p 3 ) than in female (16.4±3.6 cm 3 ) groups. These physiological references may be useful for further MRI investigations of masticatory system pathologies. (authors)

  13. Improving Marine Ecosystem Models with Biochemical Tracers

    Science.gov (United States)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  14. Study of movement of fly ash by radioactive tracer studies at Ennore Thermal Power Station (Tamil Nadu)

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, L K; Dange, A P

    1982-01-01

    This paper presents a study of the movement of fly ash from the Thermal Power Station at Ennore dumped in the ocean. The purpose of the study was to ensure that the ash dumped in the sea does not find its way to intake of the power station through the mouth of the river situated at a distance of 2 kms north. In such situations the use of radioactive tracer studies is found to be very effective and these studies indicated the necessity of dumping the fly ash beyond 6 m depth in the sea.

  15. Study of movement of fly ash by radioactive tracer studies at Ennore Thermal Power Station (Tamil Nadu)

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, L K; Dange, A P [Central Water and Power Research Station, Pune (India)

    1982-01-01

    This paper presents a study of the movement of fly ash from the Thermal Power Station at Ennore dumped in the ocean. The purpose of the study was to ensure that the ash dumped in the sea does not find its way to intake of the power station through the mouth of the river situated at a distance of 2 kms north. In such situations the use of radioactive tracer studies is found to be very effective and these studies indicated the necessity of dumping the fly ash beyond 6m depth in the sea.

  16. Study on Radioecology and Tracer of Iodine-129

    International Nuclear Information System (INIS)

    Xiaolin, Hou

    2004-01-01

    Iodine-129 (15.7 Ma) is a naturally occurring radioisotope of iodine. The ratio of 129 I/ 127 I was estimated to be ∼ 10 -12 in the ocean and 10 -11 in the territorial environment in pre-nuclear era, releases from nuclear weapon tests have increased this ratio to ∼ 10 -10 . However, a large amount of iodine-129 was released from various nuclear facilities, and the greatest releases of 129 I are from two European reprocessing plants, especially in recent years. By 1998, 2600 Kg and 220 Kg 129 I have been discharged to the marine environment and atmosphere from La Hague (France) and Sellafield reprocessing plants, respectively. This amount is tens times larger than the total 129 I inventory in the pre-nuclear ocean and weapon test releases. Although there is no significant radiation risk for the human health at present level of 129 I, the continuously increasing production and release of 129 I make the accumulation of 129 I in the environment, immigration, cycle and long term radioecological risk should be give more attention due to its long half-life, high accumulation in human thyroid and high mobility. Iodine is a conservative element in the ocean, the large amount of iodine-129 discharged to the marine system can therefore be used as a oceanographic tracer to study the physical dispersion, mixing and circulative processes of water mass in the ocean. In Riso national laboratory, a radiochemical neutron activation analysis method was developed, using this method the radioecology and tracer of iodine-129 was studied. Some representative works are presented below. (1) Evaluation of radiation exposure of humans to iodine-129. The human and animal thyroids collected from different places, such as Tianjin in China, Gemol in Belarus, Ribe in Denmark, human urine in Denmark, seafood in China were analysed for iodine-129 concentration and 129 I/ 127 I ratio, the exposure level were compared with other places. (2) Reconstruction of radiation dose from I-131 in the

  17. Acupuncture meridians demythified. A study using the radioactive tracer method

    International Nuclear Information System (INIS)

    Simon, J.; Esquerre, J.P.; Guiraud, R.; Guiraud, G.; Lazorthes, Y.

    1988-01-01

    Radioactive trajectories can be visualized by injecting a radioactive tracer, technetium 99 m, at the site of acupuncture points. To determine the exact nature of these trajectories we performed several experiments on healthy volunteers, and our results may be summarized as follows. The target organs of technetium 99 m, and notably the thyroid gland, were always visualized. The circulating radioactivity, visible on scintiscans and confirmed by venous blood counts, was not negligible. The radioactive trajectories we observed were often divided at their starting point and did not extend along the whole length of the acupuncture meridians they might have made visible. The radioactive trajectories disappeared after venous blockade to reappear when the blockade was lifted. Finally, the radioactive trajectories obtained were very similar after injection at the acupuncture point and at a control point. These findings indicate a lymphatic and venous drainage of the radioactive tracer at the site of injection followed by transportation through the veins, rather than visualization of acupuncture meridians as suggested by some authors [fr

  18. Acupuncture meridians demythified. A study using the radioactive tracer method

    Energy Technology Data Exchange (ETDEWEB)

    Simon, J.; Esquerre, J.P.; Guiraud, R.; Guiraud, G.; Lazorthes, Y.

    1988-07-01

    Radioactive trajectories can be visualized by injecting a radioactive tracer, technetium 99 m, at the site of acupuncture points. To determine the exact nature of these trajectories we performed several experiments on healthy volunteers, and our results may be summarized as follows. The target organs of technetium 99 m, and notably the thyroid gland, were always visualized. The circulating radioactivity, visible on scintiscans and confirmed by venous blood counts, was not negligible. The radioactive trajectories we observed were often divided at their starting point and did not extend along the whole length of the acupuncture meridians they might have made visible. The radioactive trajectories disappeared after venous blockade to reappear when the blockade was lifted. Finally, the radioactive trajectories obtained were very similar after injection at the acupuncture point and at a control point. These findings indicate a lymphatic and venous drainage of the radioactive tracer at the site of injection followed by transportation through the veins, rather than visualization of acupuncture meridians as suggested by some authors.

  19. Development of radioisotope tracer technology and nucleonic control system

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee and others

    1999-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and basic technology of nuclear control systems that are widely used for automation of industrial plants, and to build a strong tracer group to support the local industries. In relation to the tracer technology, the data acquisition system, the column scanning equipment and the detection pig for a leakage test have been developed. In order to use in analyzing data of tracer experiments, a computer program for the analysis of residence time distribution has been created as well. These results were utilized in developing the tracer technologies, such as the column scanning, the flow measurement using the dilution method, the simultaneous monitoring rotational movement of piston rings and the optimization of a waste water treatment facility, and the technologies were successfully demonstrated in the local industrial. The stripper of RFCC reactor has been examined to find an unwanted structure in it by imminent request from the industry. Related to the development of nucleonic control system, the state of art report on the technology has been written and an equipment for the analysis of asphalt content has been developed. (author)

  20. Sonographic and MRI evaluation of the plantar plate: a prospective study

    International Nuclear Information System (INIS)

    Gregg, Julie; Silberstein, Morry; Schneider, Timothy; Marks, Paul

    2006-01-01

    The purpose of this study was to establish the accuracy of ultrasound in the examination of the plantar plate by comparing it with MRI, or if available, surgical findings. The lesser metatarsophalangeal joint plantar plates of 40 symptomatic and 40 asymptomatic feet (160 asymptomatic and 160 symptomatic plantar plates) were examined with ultrasound and MRI. Patients treated with surgery were chosen on a clinical basis and provided surgical correlation for the imaging techniques. Symptomatic patients with metatatarsalgia and suspected metatarsophalangeal joint instability were referred by an orthopedic foot specialist; asymptomatic feet were obtained either through examination of the contralateral foot of the symptomatic patients or volunteers. Ultrasound detected 75/160 and 139/160 plantar plates torn in the asymptomatic and symptomatic groups, respectively. MRI detected 56/160 and 142/160 tears in the symptomatic and asymptomatic groups, respectively. The sensitivity of MRI and ultrasound with surgical correlation was calculated to be 87 and 96%, respectively, with poor specificity. Ultrasound correlates moderately with MRI in the evaluation of the plantar plate. Surgical correlations, although limited (n=10), indicate ultrasound is superior to MRI with more accurate detection of tears. (orig.)

  1. Statistical dynamic imaging of RI-labeled tracer from list-mode PET data

    International Nuclear Information System (INIS)

    Tanimoto, Michiaki; Kuroda, Yoshihiro; Oshiro, Osamu; Watabe, Hiroshi; Kuroda, Tomohiro

    2009-01-01

    Positron emission tomography (PET) can be used in physiological analysis to illustrate physiological states by visualizing the accumulation of radioisotope (RI)-labeled tracer in specific organs or tissues. PET obtains spatio-temporal statistics in the form of list-mode data. However, conventional imaging techniques, which sum up list-mode data over a given time period, cannot depict detailed temporal dynamics of the RI-labeled tracer. In this study, a spatio-temporal analysis approach was employed to visualize the temporal flow dynamics of RI-labeled tracer from the obtained list-mode data. Experiments to assess the visualization of simulated RI-labeled tracer dynamics as well as RI-labeled tracer dynamics in a vascular phantom showed that the proposed method successfully depicted detailed temporal flow dynamics that could not be visualized using conventional methods. (author)

  2. Results of repeat tracer tests at Ohaaki, NZ

    International Nuclear Information System (INIS)

    McCabe, W.J.; Morris, C.

    1995-01-01

    During 20 years of tracer testing at Ohaaki a number of wells have been used more than once as tracer injection sites. In studying the various responses obtained it has been necessary to consider variations in the experimental test conditions before making comparisons which relate to field conditions. Some very significant changes have occurred in the field hydrology in recent years and water flow speeds as high as those encountered at Wairakei have been demonstrated. (author). 4 refs., 2 tabs., 10 figs

  3. MRI outcomes with cladribine tablets for multiple sclerosis in the CLARITY study

    DEFF Research Database (Denmark)

    Comi, Giancarlo; Cook, Stuart D; Giovannoni, Gavin

    2013-01-01

    We herein provide a comprehensive assessment of magnetic resonance imaging (MRI) outcomes from CLARITY, a 96-week, double-blind study demonstrating significant clinical and MRI improvements in patients with relapsing-remitting multiple sclerosis (RRMS) treated with cladribine tablets. Patients...... with RRMS were randomized 1:1:1 to annual short-course therapy with cladribine tablets cumulative dose 3.5 or 5.25 mg/kg or placebo. MRI endpoints included mean number of T1 gadolinium-enhancing (Gd+), active T2 and combined unique (CU) lesions/patient/scan. MRI-measured disease activity was significantly...... reduced in both cladribine tablets groups versus placebo. The proportion of patients with no active lesions at study end was: T1 Gd+ lesions: 86.8 and 91.0 versus 48.3 % (p ...

  4. Fifty years of radiochemical tracers

    International Nuclear Information System (INIS)

    Evans, E.A.

    1992-01-01

    During the past 50 years radiochemical tracers, usually in the form of isotopically labelled organic compounds, have been essential tools to further advance our knowledge at the frontiers of a great variety of scientific developments in the life sciences. This plenary lecture reviews necessarily selected highlights in the synthesis and applications of such radiochemical tracers. Included are examples where important advances, made possible by using radiochemicals, have contributed to improving the quality of life on this planet. The principal radioisotopes involved, 14 C, 3 H, 35 S, 32 P, 125 I, are all relatively safe to handle and are commercially available at maximum theoretical specific activity (carrier free). The compounds labeled with these radioisotopes are used in many fields of research which include biosynthesis and biotechnology studies, cell biology, drug metabolism, clinical research and environmental applications, and are briefly reviewed. (author). 55 refs

  5. Guidebook on radioisotope tracers in industry

    International Nuclear Information System (INIS)

    1990-01-01

    The idea of using tracers (chemical, dyes, etc.) in the investigation of complex physical phenomena has always attracted the attention of scientists and engineers. When radioactive isotopes became available it was immediately recognized that they offered an almost ideal solution to tracer selection. This book is devoted to reviewing the present status of the tracer method as such and to its applications to those branches of industry which have derived large benefits from the use of this modern technology. The main objectives of the IAEA's Industrial Applications and Chemistry Section is to help Member States in introducing to their own industries the different isotope and radiation techniques which have become available as a result of developments in the nuclear sciences. This section proposed the preparation of this guidebook, putting together various radiotracer methods and the experience obtained so far in their industrial use. Chapters 2 to 4 cover the general concept of tracers, technology and safety aspects, as well as data evaluation and interpretation. In chapter 5, therefore, general applications are discussed. In chapter 6, specialists in selected fields discuss their experience in radiotracer applications in various types of industrial activity. Most case studies are illustrated by at least one detailed example of an experiment carried out at an industrial installation. Current trends in the development of radiotracer methods are discussed in chapter 7, from both a theoretical and a practical viewpoint. Some possible new RTT applications in the future are also discussed here. Sealed radioactive sources are used almost as often as radioisotope tracers in industrial measurements. Annex I gives a short review of these techniques. Readers who are interested in the basic principles of radioisotope production will find the necessary information in Annex II. Annexes III, V and VI provide a demonstration of fundamental relations and properties; useful

  6. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  7. The use of tracer techniques in pesticide balance and metabolism studies

    International Nuclear Information System (INIS)

    Fuehr, F.

    1977-01-01

    The radioisotope tracing technique has been a useful tool in obtaining extensive information on the fate of pesticides in the soil-plant systems, including their uptake, transport and metabolism by plants; their photochemical, chemical and microbial degradation; their adsorption, desorption and translocation in soil; and their bioavailability to untreated crops. A pesticide balance study under practical field conditions using radio labelling can examine a number of factors affecting the fate of a compound at the same time and assess the magnitude of the major processes involved. On the basis of these results, more detailed studies are then formulated to be conducted under an exactly defined environment of a growth chamber or a laboratory. The use of tracer techniques in such studies is reported. (author)

  8. Transport of Perfluorocarbon Tracers in the Cranfield Geological Carbon Sequestration Project

    Science.gov (United States)

    Moortgat, J.; Soltanian, M. R.; Amooie, M. A.; Cole, D. R.; Graham, D. E.; Pfiffner, S. M.; Phelps, T.

    2017-12-01

    A field-scale carbon dioxide (CO2) injection pilot project was conducted by the Southeast Regional Sequestration Partnership (SECARB) at Cranfield, Mississippi. Two associated campaigns in 2009 and 2010 were carried out to co-inject perfluorocarbon tracers (PFTs) and sulfur hexafluoride (SF6) with CO2. Tracers in gas samples from two observation wells were analyzed to construct breakthrough curves. We present the compiled field data as well as detailed numerical modeling of the flow and transport of CO2, brine, and introduced tracers. A high-resolution static model of the formation geology in the Detailed Area Study (DAS) was used in order to capture the impact of connected flow pathways created by fluvial channels on breakthrough curves and breakthrough times of PFTs and SF6 tracers. We use the cubic-plus-association (CPA) equation of state, which takes into account the polar nature of water molecules, to describe the phase behavior of CO2-brine-tracer mixtures. We show how the combination of multiple tracer injection pulses with detailed numerical simulations provide a powerful tool in constraining both formation properties and how complex flow pathways develop over time.

  9. Bottom sediment transport study at Haiphong port using radioactive scandium as tracer

    International Nuclear Information System (INIS)

    Pham Ngoc Chuong; Phan Son Hai; Pham Duy Hien

    1993-01-01

    A radioisotope tracer experiment was performed for investigating the bedload movement at the site near the access channel to Haiphong port, North Vietnam. The scandium glass and a number of mechanical devices were manufactured locally for the experiment. Simple and safe procedures were adopted for the production, transportation and injection of radioactive tracer materials. Five tracking experiments were carried out covering the period of 84 days in winter 1992-1993. The experimental results provide a firm basis for elaborating appropriate measures against the siltation problem at Haiphong port, especially for the design of a new access channel with a better orientation with respect to the directions of the water flow and bedload transport, as proposed recently by the Port Authority. (Author). 2 refs, 4 figs

  10. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  11. Considerations on the assessment of economic benefits of industrial tracer application

    International Nuclear Information System (INIS)

    Guizerix, J.; Margrita, R.

    1990-01-01

    The benefit of a particular tracer study which can always theoretically be derived is practically very difficult to assess for decision-making which is more often based on rough estimates of it. Other criteria, as safety, environmental protection, 'social benefit', may replace the purely economic considerations. The economic benefits of industrial tracer applications can clearly be perceived through the commercial success of businesses offering tracer services, which implies that all factors involved in the law of supply and demand have (tacitly or explictly) been accounted. (orig.) [de

  12. Flow visualization in superfluid helium-4 using He2 molecular tracers

    Science.gov (United States)

    Guo, Wei

    Flow visualization in superfluid helium is challenging, yet crucial for attaining a detailed understanding of quantum turbulence. Two problems have impeded progress: finding and introducing suitable tracers that are small yet visible; and unambiguous interpretation of the tracer motion. We show that metastable He2 triplet molecules are outstanding tracers compared with other particles used in helium. These molecular tracers have small size and relatively simple behavior in superfluid helium: they follow the normal fluid motion at above 1 K and will bind to quantized vortex lines below about 0.6 K. A laser-induced fluorescence technique has been developed for imaging the He2 tracers. We will present our recent experimental work on studying the normal-fluid motion by tracking thin lines of He2 tracers created via femtosecond laser-field ionization in helium. We will also discuss a newly launched experiment on visualizing vortex lines in a magnetically levitated superfluid helium drop by imaging the He2 tracers trapped on the vortex cores. This experiment will enable unprecedented insight into the behavior of a rotating superfluid drop and will untangle several key issues in quantum turbulence research. We acknowledge the support from the National Science Foundation under Grant No. DMR-1507386 and the US Department of Energy under Grant No. DE-FG02 96ER40952.

  13. Bone formation rather than inflammation reflects ankylosing spondylitis activity on PET-CT: a pilot study.

    Science.gov (United States)

    Bruijnen, Stefan T G; van der Weijden, Mignon A C; Klein, Joannes P; Hoekstra, Otto S; Boellaard, Ronald; van Denderen, J Christiaan; Dijkmans, Ben A C; Voskuyl, Alexandre E; van der Horst-Bruinsma, Irene E; van der Laken, Conny J

    2012-04-02

    Positron Emission Tomography - Computer Tomography (PET-CT) is an interesting imaging technique to visualize Ankylosing Spondylitis (AS) activity using specific PET tracers. Previous studies have shown that the PET tracers [18F]FDG and [11C](R)PK11195 can target inflammation (synovitis) in rheumatoid arthritis (RA) and may therefore be useful in AS. Another interesting tracer for AS is [18F]Fluoride, which targets bone formation. In a pilot setting, the potential of PET-CT in imaging AS activity was tested using different tracers, with Magnetic Resonance Imaging (MRI) and conventional radiographs as reference. In a stepwise approach different PET tracers were investigated. First, whole body [18F]FDG and [11C](R)PK11195 PET-CT scans were obtained of ten AS patients fulfilling the modified New York criteria. According to the BASDAI five of these patients had low and five had high disease activity. Secondly, an extra PET-CT scan using [18F]Fluoride was made of two additional AS patients with high disease activity. MRI scans of the total spine and sacroiliac joints were performed, and conventional radiographs of the total spine and sacroiliac joints were available for all patients. Scans and radiographs were visually scored by two observers blinded for clinical data. No increased [18F]FDG and [11C](R)PK11195 uptake was noticed on PET-CT scans of the first 10 patients. In contrast, MRI demonstrated a total of five bone edema lesions in three out of 10 patients. In the two additional AS patients scanned with [18F]Fluoride PET-CT, [18F]Fluoride depicted 17 regions with increased uptake in both vertebral column and sacroiliac joints. In contrast, [18F]FDG depicted only three lesions, with an uptake of five times lower compared to [18F]Fluoride, and again no [11C](R)PK11195 positive lesions were found. In these two patients, MRI detected nine lesions and six out of nine matched with the anatomical position of [18F]Fluoride uptake. Conventional radiographs showed structural

  14. Studies on hippocampal sclerosis by 1H MRS and MRI

    International Nuclear Information System (INIS)

    Qi Jing; Du Xiangke; Luan Guoming; Wang Dehang

    2000-01-01

    Objective: To determine the relative utility of 1 H MRS and MRI for pre-surgical diagnosis of hippocampal sclerosis by the study on metabolic abnormalities and anatomical alterations in the brain of patients with temporal lobe epilepsy (TLE). Methods: 1 H MRS and MRI were performed on 8 patients with pathologically confirmed hippocampal sclerosis and 8 healthy volunteers on 2.0 T 1 H MRS/MRI system. The values of NAA, Cr and Cho were calculated by integration of their peaks and the ratios of NAA/Cr, NAA/(Cr + Cho), and Cho/Cr were measured. The volumes of both hippocampal formations in every case were observed and the differences of hippocampal formation (DHF) were analyzed. Results: The ratios of NAA/Cr, NAA/(Cr + Cho), and Cho/Cr in ipsilateral side were 0.55, 1.77 and 1.38, and in control subjects were 0.77, 1.38 and 1.06 separately. The ratios of NAA/Cr and NAA/(Cr + Cho) were decreased on ipsilateral side (t = 2.15, 4.83 separately, P 1 H MRS and MRI, seven of eight cases could be lateralized. Conclusion: 1 H MRS is sensitive to the diagnosis of neuron abnormality and coincident well with the pathological results 1 H MRS and MRI correctly lateralize most patients with hippocampal sclerosis and complement each other in final lateralization. The combination of 1 H MRS and MRI can provide useful information for pre-surgical diagnosis of hippocampal sclerosis

  15. National Biomedical Tracer Facility: Project definition study

    International Nuclear Information System (INIS)

    Heaton, R.; Peterson, E.; Smith, P.

    1995-01-01

    The Los Alamos National Laboratory is an ideal institution and New Mexico is an ideal location for siting the National Biomedical Tracer Facility (NBTF). The essence of the Los Alamos proposal is the development of two complementary irradiation facilities that combined with our existing radiochemical processing hot cell facilities and waste handling and disposal facilities provide a low cost alternative to other proposals that seek to satisfy the objectives of the NBTF. We propose the construction of a 30 MeV cyclotron facility at the site of the radiochemical facilities, and the construction of a 100 MeV target station at LAMPF to satisfy the requirements and objectives of the NBTF. We do not require any modifications to our existing radiochemical processing hot cell facilities or our waste treatment and disposal facilities to accomplish the objectives of the NBTF. The total capital cost for the facility defined by the project definition study is $15.2 M. This cost estimate includes $9.9 M for the cyclotron and associated facility, $2.0 M for the 100 MeV target station at LAMPF, and $3.3 M for design

  16. National Biomedical Tracer Facility: Project definition study

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, R.; Peterson, E. [Los Alamos National Lab., NM (United States); Smith, P. [Smith (P.A.) Concepts and Designs (United States)

    1995-05-31

    The Los Alamos National Laboratory is an ideal institution and New Mexico is an ideal location for siting the National Biomedical Tracer Facility (NBTF). The essence of the Los Alamos proposal is the development of two complementary irradiation facilities that combined with our existing radiochemical processing hot cell facilities and waste handling and disposal facilities provide a low cost alternative to other proposals that seek to satisfy the objectives of the NBTF. We propose the construction of a 30 MeV cyclotron facility at the site of the radiochemical facilities, and the construction of a 100 MeV target station at LAMPF to satisfy the requirements and objectives of the NBTF. We do not require any modifications to our existing radiochemical processing hot cell facilities or our waste treatment and disposal facilities to accomplish the objectives of the NBTF. The total capital cost for the facility defined by the project definition study is $15.2 M. This cost estimate includes $9.9 M for the cyclotron and associated facility, $2.0 M for the 100 MeV target station at LAMPF, and $3.3 M for design.

  17. Lanthanide-based fluorescent tracers in complex media

    International Nuclear Information System (INIS)

    Brichart, Thomas

    2014-01-01

    Tracers are objects allowing the determination of the position or the distribution of a product; tracers are currently used in a great variety of domains. Despite the fact that each field has it's own specifications, it is possible to find tracers in medicine (contrast agents), anti-counterfeiting or geological exploration. We have developed lanthanide complex tracers for oil field injection waters. Those tracers, derived from the DOTA, have been detected at concentration lower than 1 ppb, thanks to a simple and compact apparatus. This detection has been made possible by the use of time-resolved fluorescence spectroscopy, this technique allows us to get rid of the background noise created by the intrinsic fluorescence of oil residues that are present in production waters. We also demonstrated how we can, through a reverse microemulsion synthesis, encapsulate several different dyes inside a single nanoparticle composed of a gold core and a silica shell. We showed as well, how those particles can be used as smart tracers to gather data, such as temperature, pH, solvents, etc. inside the well. Finally the use of lanthanides and scale inhibitors properties allowed us to create a simple and fast dosing protocol of such scale inhibitors in injection waters. This dosage will then allow the quick adjustment of their concentration inside each well. (author) [fr

  18. UKAEA code of practice for tracer and irradiation studies involving the use of volunteers

    International Nuclear Information System (INIS)

    Pritchard, J.N.; Morgan, A.

    1987-06-01

    The subject is discussed under the following headings: 1) General considerations in volunteer studies (informed consent, beneficial objectives, recruitment from within or without the workforce, records, compensation, codes of practice, confidentiality etc.) 2) Tracer and irradiation studies approval committee, (terms of reference, membership, dose limitations, assessment of chemical toxicity, procedure for submitting proposals) 3) Obtaining a project licence 4) Conduct of volunteer experiments 5) The use of non-authority volunteers. (U.K.)

  19. Proton nuclear magnetic resonance study on the barrier function of pig corneal epithelium and endothelium

    International Nuclear Information System (INIS)

    Yokoi, Norihiko; Kinoshita, Shigeru; Morimoto, Taketoshi; Yoshizaki, Kazuo.

    1995-01-01

    Using gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) as a tracer, the barrier function of the corneal epithelium and endothelium was evaluated by proton nuclear magnetic resonance. Whole pig eyes and cornea excised with scleral rim, which had been incubated in dextran-added Gd-DTPA solution, were subjected to T 1 relaxation measurement and magnetic resonance imaging (MRI). After incubation, the T 1 relaxation rate (1/T 1 ) of the excised cornea increased to a steady value, whereas that of the cornea from the whole eye increased only slightly. These results indicated that the increase in the T 1 relaxation rate of the excised cornea was attributable to Gd-DTPA penetration from the corneal endothelium and that the corneal epithelium exhibited a strong barrier function against Gd-DTPA entry. The MRI study also confirmed the strong barrier, enhanced signals being detected within the aqueous fluid in the T 1 -weighted image only when the corneal epithelium was abraded. Since Gd-DTPA scarcely penetrates the intact corneal epithelium, Gd-DTPA-enhanced MRI shows potential as a quantitative tracer in evaluating epithelial barrier disruption. (author)

  20. Study of leak detection using tracers in a bottling plant in Mexico

    International Nuclear Information System (INIS)

    Vizuet Gonzalez, Jorge; Reyes Jimenez, Jose Luis; Molina, Gustavo

    2005-01-01

    The Instituto Nacional de Investigaciones Nucleares (ININ), Mexico, promoted the application of different techniques, involving the use of radioactive materials. Among them is the use of radioactive material as a medium tracer in the industry. Below is a study of locating leaks in ducts collectors of process water of a bottling plant which had several problems, one was not able to stop production, and most important, having to disassemble a large amount of machinery and equipment, in order to open the floor and locate the leak

  1. Imaging large vessel vasculitis with fully integrated PET/MRI: a pilot study

    International Nuclear Information System (INIS)

    Einspieler, Ingo; Pyka, Thomas; Eiber, Matthias; Thuermel, Klaus; Wolfram, Sabine; Moog, Philipp; Reeps, Christian; Essler, Markus

    2015-01-01

    The aim of this study was to evaluate the feasibility of hybrid [ 18 F]fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI in patients with large vessel vasculitis (LVV) by comparing visual and quantitative parameters to that of PET/CT. Furthermore, the value of PET/MRI in disease activity and extent of LVV was assessed. A total of 16 [ 18 F]FDG PET/MRI and 12 [ 18 F]-FDG PET/CT examinations were performed in 12 patients with LVV. MRI of the vessel wall by T1-weighted and T2-weighted sequences was used for anatomical localization of FDG uptake and identification of morphological changes associated with LVV. In addition, contrast-enhanced (CE) magnetic resonance angiography (MRA) was performed. The vascular FDG uptake in the vasculitis group was compared to a reference group of 16 patients using a four-point visual score. Visual scores and quantitative parameters [maximum standardized uptake value (SUV max ) and target to background ratio (TBR)] were compared between PET/MRI and PET/CT. Furthermore, correlations between C-reactive protein (CRP) and quantitative PET results, as well the extent of vasculitis in PET, MRI/CE-MRA and combined PET/MRI, were analysed. TBRs, SUV max values and visual scores correlated well between PET/MRI and PET/CT (r = 0.92, r = 0.91; r = 0.84, p < 0.05). There was no significant difference between both modalities concerning SUV max measurements and visual scores. In PET/MRI, PET alone revealed abnormal FDG uptake in 86 vascular regions. MRI/CE-MRA indicated 49 vessel segments with morphological changes related to vasculitis, leading to a total number of 95 vasculitis regions in combination with PET. Strong and significant correlations between CRP and disease extent in PET alone (r = 0.75, p = 0.0067) and PET/MRI (r = 0.92, p < 0.0001) in contrast to MRI/CE-MRA only were observed. Regarding disease activity, no significant correlations were seen between quantitative PET results and CRP, although there was a trend towards

  2. Imaging large vessel vasculitis with fully integrated PET/MRI: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Einspieler, Ingo; Pyka, Thomas; Eiber, Matthias [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany); Thuermel, Klaus; Wolfram, Sabine; Moog, Philipp [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Nephrology, Munich (Germany); Reeps, Christian [Technische Universitaet Muenchen, Department of Vascular Surgery, Klinikum rechts der Isar, Munich (Germany); Essler, Markus [Rheinische Friedrich-Wilhelms-Universitaet, Department of Nuclear Medicine, Universitaetsklinikum Bonn, Bonn (Germany)

    2015-04-16

    The aim of this study was to evaluate the feasibility of hybrid [{sup 18}F]fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI in patients with large vessel vasculitis (LVV) by comparing visual and quantitative parameters to that of PET/CT. Furthermore, the value of PET/MRI in disease activity and extent of LVV was assessed. A total of 16 [{sup 18}F]FDG PET/MRI and 12 [{sup 18}F]-FDG PET/CT examinations were performed in 12 patients with LVV. MRI of the vessel wall by T1-weighted and T2-weighted sequences was used for anatomical localization of FDG uptake and identification of morphological changes associated with LVV. In addition, contrast-enhanced (CE) magnetic resonance angiography (MRA) was performed. The vascular FDG uptake in the vasculitis group was compared to a reference group of 16 patients using a four-point visual score. Visual scores and quantitative parameters [maximum standardized uptake value (SUV{sub max}) and target to background ratio (TBR)] were compared between PET/MRI and PET/CT. Furthermore, correlations between C-reactive protein (CRP) and quantitative PET results, as well the extent of vasculitis in PET, MRI/CE-MRA and combined PET/MRI, were analysed. TBRs, SUV{sub max} values and visual scores correlated well between PET/MRI and PET/CT (r = 0.92, r = 0.91; r = 0.84, p < 0.05). There was no significant difference between both modalities concerning SUV{sub max} measurements and visual scores. In PET/MRI, PET alone revealed abnormal FDG uptake in 86 vascular regions. MRI/CE-MRA indicated 49 vessel segments with morphological changes related to vasculitis, leading to a total number of 95 vasculitis regions in combination with PET. Strong and significant correlations between CRP and disease extent in PET alone (r = 0.75, p = 0.0067) and PET/MRI (r = 0.92, p < 0.0001) in contrast to MRI/CE-MRA only were observed. Regarding disease activity, no significant correlations were seen between quantitative PET results and CRP, although there

  3. White matter lesions in watershed territories studied with MRI and parenchymography: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Minkner, K; Lovblad, K.O.; Yilmaz, H; Alimenti, A.; Delavelle, J; Ruefenacht, D.A. [University Hospital of Geneva, Department of Radiology, Geneva 14 (Switzerland); Sekoranja, L; Sztajzel, R [University Hospital of Geneva, Clinic of Neurology, Geneva 14 (Switzerland)

    2005-06-01

    Brain aging affects an increasing segment of the population and the role of chronic cerebrovascular disease is considered to be one of the main parameters involved. For this purpose we compared retrospectively MRI data with digitized subtraction angiography (DSA) data in a group of 50 patients focusing onto the watershed area of the carotid artery vascular territories. In order to evaluate the presence of white matter lesions (WML) in the hemispheric watershed areas, coronal fluid-attenuated inversion-recovery or axial T2 weighted MRI images of patients with symptomatic cerebrovascular insufficiency areas were compared with the capillary phase of DSA studies in anterior-posterior projection. Presence of cerebrovascular occlusive disease was evaluated on DSA using North American symptomatic carotid endarterectomy trial criteria and including evaluation of collateral vascular supply. Pathological MRI findings in the region of the watershed territories correlated overall in 66% of cases with a defect or delayed filling on DSA. In the case of asymmetrical MRI findings, there was a pathological finding of the capillary phase in the watershed area in 92% of DSA studies. Hypoperfusion in the capillary phase of the watershed area as seen on DSA correlated with the stenosis degree of the concerned carotid artery. Our findings suggest that asymmetrical findings of WML in the watershed areas as seen on MRI are caused by hemodynamic effect and a differentiation between small vessel disease and a consequence of distant stenosis may be possible under such conditions. (orig.)

  4. Effects of MRI on the electrophysiology of the motor cortex: a TMS study

    International Nuclear Information System (INIS)

    Schlamann, Marc; Pietrzyk, T.; Yoon, M.S.; Gerwig, M.; Kastrup, O.; Maderwald, S.; Forsting, M.; Ladd, S.C.; Duisburg-Essen Univ.; Bitz, A.; Ladd, M.E.

    2009-01-01

    The increasing spread of high-field and ultra-high-field MRI scanners encouraged a new discussion on safety aspects of MRI examinations. Earlier studies report altered acoustically evoked potentials. This finding was not able to be confirmed in later studies. In the present study transcranial magnetic stimulation (TMS) was used to evaluate whether motor cortical excitability may be altered following MRI examination even at field strength of 1.5 T. In 12 right-handed male volunteers individual thresholds for motor responses and then the length of the post-excitatory inhibition (silent period) were determined. Subsequently the volunteers were examined in the MRI scanner (Siemens Avanto, 1.5 T) for 63 minutes using gradient and spin echo sequences. MRI examination was immediately followed by another TMS session and a third 10 minutes later. As a control condition, the 12 subjects spent one hour in the scanner without examination and one hour on a couch without the presence of a scanner. After MRI examination, the silent period was significantly lengthened in all 12 subjects and then tended to the initial value after 10 min. Motor thresholds were significantly elevated and then normalized after 10 minutes. No significant effects were found in the control conditions. (orig.)

  5. [Use of MRI before biopsy in diagnosis of prostate cancer: Single-operator study].

    Science.gov (United States)

    Bassard, S; Mege, J-L

    2015-12-01

    The diagnostic for prostate cancer is changing. To improve the detection of this cancer, urologists expect a lot from the contribution of magnetic resonance imaging (MRI). What is the role of this imaging in prostate cancer detection? This is a retrospective study, from 2011 to 2013, mono-centric and single-operator. Of the 464 needle biopsy of the prostate (BP), we excluded those with PSA>20 ng/mL or digital rectal examination (DRE)>T3. The remaining 430 BP were submitted or not to a 1.5 tesla MRI with pelvic antenna. The primary aim is the overall detection of prostate cancer. Secondary aim was the detection rate during the first series of BP and repeat BP, between the two groups in the MRI group. MRI and MRI without populations are comparable for age (63.3 vs 64.6), PSA (6.10 vs 6.13), DRE>T1c, prostate volume (55.4 cm(3) vs 51.7 cm(3)). There is no significant difference in overall detection between the two groups (P=0.12). There is no significant difference in cancer detection between the first BP (P=0.13) and the repeat BP (P=0.07). There is a significant difference in the early detection of BP MRI group (P=0.03) but not for the BP repeat MRI group (P=0.07). For 108 BP iterative MRI group, there were 67 BP targeted "mentally" with MRI: 18 cancers were detected, making a 25% detection rate. This study helps to highlight the value of MRI in the early rounds of BP but we can ask the value of this imaging during repeat biopsies. Targeted biopsies "mentally" do not have the expected detection sensitivity and seems to require a three-dimensional reconstruction to be more effective. 5. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Dynamic gadolinium-enhanced MRI evaluation of porcine femoral head ischemia and reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [Clinic for Orthopaedics and Sports Traumatology, Dreifaltigkeits-Krankenhaus GmbH, Aachener Str. 445-449, 50933 Koeln (Germany); Drescher, W. [Department of Orthopaedics, Christian Albrechts University, Kiel (Germany); Becker, C. [Department of Orthopaedics, Heinrich Heine University, Duesseldorf (Germany); Sangill, R.; Stoedkilde-Joergensen, H. [Institute for Magnetic Resonance Imaging Tomography, University of Aarhus, Skejby Hospital, Aarhus (Denmark); Heydthausen, M. [Computing Center, Heinrich Heine University, Duesseldorf (Germany); Hansen, E.S.; Buenger, C. [Spine Section, Department of Orthopaedics, University of Aarhus (Denmark)

    2003-02-01

    To examine the potential of gadolinium (Gd)-enhanced dynamic MRI in the detection of early femoral head ischemia. Furthermore, to apply a three-compartment model to achieve a clinically applicable MR index for femoral head perfusion during the steady state and arterial hip joint tamponade.Design and materials In a porcine model femoral head perfusion was measured by radioactive tracer microspheres and by using a dynamic Gd-enhanced MRI protocol. Femoral head perfusion measurements and MRI tests were performed unilaterally before, during and after the experimentally induced ischemia of one of the hip joints. Ischemia was induced by increasing intra-articular pressure to 250 mmHg. All pigs showed ischemia of the femoral head epiphysis under hip joint tamponade followed by reperfusion to the same level as before joint tamponade. In two cases perfusion after removal of tamponade continued to be low. In dynamic MRI measurements increases in signal intensity were seen after intravenous infusion of Gd-DTPA, followed by a slow decrease in signal intensity. The signal-intensity curve during femoral head ischemia had a minor increase. Also the coefficient determined was a helpful indicator of femoral head ischemia. Femoral head blood flow as measured by microspheres fell significantly under joint tamponade. Early detection of this disturbed regional blood flow was possible using a dynamic MRI procedure. A biomathematical model resulted from the evaluation of the intervals of signal intensity over time which allows detection of bone blood flow changes at a very early stage. Using this new method earlier detection of femoral head necrosis may be possible. (orig.)

  7. MRI Primer

    International Nuclear Information System (INIS)

    Oldendorf, W.; Oldendorf, W. Jr.

    1991-01-01

    Designed for studies, radiologists, and clinicians at all levels of training, this book provides a basic introduction to the principles, physics, and instrumentation of magnetic resonance imaging. The fundamental concepts that are essential for the optimal clinical use of MRI are thoroughly explained in easily accessible terms. To facilitate the reader's comprehension, the material is presented nonmathematically, using no equations and a minimum of symbols and abbreviations. MRI Primer presents a clear account of the phenomenon of nuclear magnetic resonance and the use of gradient magnetic fields to create clinically useful images of cross-sectional slices. Close attention is given to the magnetization vector as a means of expressing nuclear behavior, the role of T 1 and T 2 weighing in imaging, the use of contrast agents, and the pulse sequences most often used in clinical practice, as well as to the relative capabilities and limitations of MRI and CT. The basic hardware components of an MRI scanner are described in detail. Sample MRI scans illustrate how MRI characterizes tissue. An appendix provides a brief introduction to quantum processes in MRI

  8. Characterization of a managed aquifer recharge system using multiple tracers.

    Science.gov (United States)

    Moeck, Christian; Radny, Dirk; Popp, Andrea; Brennwald, Matthias; Stoll, Sebastian; Auckenthaler, Adrian; Berg, Michael; Schirmer, Mario

    2017-12-31

    Knowledge about the residence times of artificially infiltrated water into an aquifer and the resulting flow paths is essential to developing groundwater-management schemes. To obtain this knowledge, a variety of tracers can be used to study residence times and gain information about subsurface processes. Although a variety of tracers exists, their interpretation can differ considerably due to subsurface heterogeneity, underlying assumptions, and sampling and analysis limitations. The current study systematically assesses information gained from seven different tracers during a pumping experiment at a site where drinking water is extracted from an aquifer close to contaminated areas and where groundwater is artificially recharged by infiltrating surface water. We demonstrate that the groundwater residence times estimated using dye and heat tracers are comparable when the thermal retardation for the heat tracer is considered. Furthermore, major ions, acesulfame, and stable isotopes (δ 2 H and δ 18 O) show that mixing of infiltrated water and groundwater coming from the regional flow path occurred and a vertical stratification of the flow system exist. Based on the concentration patterns of dissolved gases (He, Ar, Kr, N 2 , and O 2 ) and chlorinated solvents (e.g., tetrachloroethene), three temporal phases are observed in the ratio between infiltrated water and regional groundwater during the pumping experiment. Variability in this ratio is significantly related to changes in the pumping and infiltration rates. During constant pumping rates, more infiltrated water was extracted, which led to a higher dilution of the regional groundwater. An infiltration interruption caused however, the ratio to change and more regional groundwater is extracted, which led to an increase in all concentrations. The obtained results are discussed for each tracer considered and its strengths and limitations are illustrated. Overall, it is demonstrated that aquifer heterogeneity and

  9. Diagnostic Implications of the Reactivity of Fluorescence Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Sick, V; Westbrook, C

    2008-07-14

    Measurements of fuel concentration distributions with planar laser induced fluorescence of tracer molecules that are added to a base fuel are commonly used in combustion research and development. It usually is assumed that the tracer concentration follows the parent fuel concentration if physical properties such as those determining evaporation are matched. As an example to address this general issue a computational study of combustion of biacetyl/iso-octane mixtures was performed to investigate how well the concentration of biacetyl represents the concentration of iso-octane. For premixed mixture conditions with flame propagation the spatial concentration profiles of the two species in the flame front are separated by 110 {micro}m at 1 bar and by 11 {micro}m at 10 bar. For practical applications this spatial separation is insignificantly small. However, for conditions that mimic ignition and combustion in diesel and HCCI-like operation the differences in tracer and fuel concentration can be significant, exceeding hundreds of percent. At low initial temperature biacetyl was found to be more stable whereas at higher temperature (>1000K) iso-octane is more stable. Similar findings were obtained for a multi-component fuel comprised of iso-octane, n-heptane, methylcyclohexane, and toluene. It may be assumed that similar differences can exist for other tracer/fuel combinations. Caution has therefore to be applied when interpreting PLIF measurements in homogeneous reaction conditions such as in HCCI engine studies.

  10. Industrial tracer application in people's republic of china

    International Nuclear Information System (INIS)

    Sun Maoyi

    1987-01-01

    A number of important applications of radioisotopes and their compounds used as tracers in petroleum industry, metallurgical industry, mechanical industry, chemical industry, electronic industry, hydrology and water conservancy in China are introduced in this paper. And the tracer technique applied to entomology is also mentioned. The industrial tracer applications are successful and beneficial in People's Republic of China from the examples given. (author)

  11. MRI outcomes with cladribine tablets for multiple sclerosis in the CLARITY study.

    Science.gov (United States)

    Comi, Giancarlo; Cook, Stuart D; Giovannoni, Gavin; Rammohan, Kottil; Rieckmann, Peter; Sørensen, Per Soelberg; Vermersch, Patrick; Hamlett, Anthony C; Viglietta, Vissia; Greenberg, Steven J

    2013-04-01

    We herein provide a comprehensive assessment of magnetic resonance imaging (MRI) outcomes from CLARITY, a 96-week, double-blind study demonstrating significant clinical and MRI improvements in patients with relapsing-remitting multiple sclerosis (RRMS) treated with cladribine tablets. Patients with RRMS were randomized 1:1:1 to annual short-course therapy with cladribine tablets cumulative dose 3.5 or 5.25 mg/kg or placebo. MRI endpoints included mean number of T1 gadolinium-enhancing (Gd+), active T2 and combined unique (CU) lesions/patient/scan. MRI-measured disease activity was significantly reduced in both cladribine tablets groups versus placebo. The proportion of patients with no active lesions at study end was: T1 Gd+ lesions: 86.8 and 91.0 versus 48.3 % (p tablet groups when data were stratified by baseline disease characteristics. For example, the percentage of patients who remained lesion-free over the study was significantly greater in cladribine tablet groups than in the placebo group for all lesion types regardless of relapse category at baseline (p MRI-measured disease activity was greatly reduced by both doses of cladribine tablets, with consistent effect across clinically relevant patient populations. These findings add to our scientific understanding of the neurological impact of this therapeutic modality in patients with RRMS.

  12. The Problem of Metal Needles in Acupuncture-fMRI Studies

    Directory of Open Access Journals (Sweden)

    Florian Beissner

    2011-01-01

    Full Text Available Acupuncture is a therapy based on sensory stimulation of the human body by means of metal needles. The exact underlying mechanisms of acupuncture have not been clarified so far. Functional magnetic resonance imaging (fMRI has become an important tool in acupuncture research. Standard acupuncture needles, which are made of ferromagnetic steel, however, are problematic in acupuncture-fMRI studies for several reasons, such as attraction by the scanner's magnetic field, significant image distortions and signal-dropouts, when positioned close to the head or even heating due to absorption of radio frequency (RF. The aim of this study was to compare two novel types of acupuncture needles with a standard needle for their effect on MRI image quality. The standard needle severely reduced image quality, when located inside the RF coil. The nonferromagnetic metal needle may pose a risk due to RF heating, while the plastic needle has a significantly larger diameter. In conclusion, our recommendations are: (1 standard needles should not be used in MRI; (2 Nonferromagnetic metal needles seem to be the best choice for acupoints outside of the transmitter coil; and (3 only plastic needles are suited for points inside the coil. Laser acupuncture may be a safe alternative, too.

  13. Tracer technology modeling the flow of fluids

    CERN Document Server

    Levenspiel, Octave

    2012-01-01

    A vessel’s behavior as a heat exchanger, absorber, reactor, or other process unit is dependent upon how fluid flows through the vessel.  In early engineering, the designer would assume either plug flow or mixed flow of the fluid through the vessel.  However, these assumptions were oftentimes inaccurate, sometimes being off by a volume factor of 100 or more.  The result of this unreliable figure produced ineffective products in multiple reaction systems.   Written by a pioneering researcher in the field of chemical engineering, the tracer method was introduced to provide more accurate flow data.  First, the tracer method measured the actual flow of fluid through a vessel.  Second, it developed a suitable model to represent the flow in question.  Such models are used to follow the flow of fluid in chemical reactors and other process units, like in rivers and streams, or solid and porous structures.  In medicine, the tracer method is used to study the flow of chemicals—harmful  and harmless—in the...

  14. Commercial applications of perfluorocarbon tracer (PFT) technology

    International Nuclear Information System (INIS)

    Dietz, R.N.

    1991-06-01

    Tracer technology can be successfully applied to many leak-checking and monitoring evaluations of operating systems (e.g., building HVACs), manufacturing processes and products (e.g., air conditioners), and subsurface components and systems (e.g., underground storage tanks). Perfluorocarbon tracer (PFT) technology is the most sensitive of all tracer technologies because the ambient background levels of the five (5) routinely-used PFTs are in the range of parts per 10 15 parts of air (i.e., parts per quadrillion-ppq) and this technology's instrumentation can measure down to those levels. The effectiveness of this technology is achieved both in terms of cost (very little PFT need to be used) and detectability; for example, very small leaks can be rapidly detected. The PFT compounds, which are environmentally and biologically safe to use, are commercially available as are the sampling and analysis instrumentation. This presentation concerns (1) the steps being taken to commercialize this technology, (2) new applications of processes currently under study, and (3) applications in areas of use that will be particularly beneficial to the environment. 21 refs., 2 figs., 2 tabs

  15. Comparison of static MRI and pseudo-dynamic MRI in temporomandibular joint disorder patients

    International Nuclear Information System (INIS)

    Lee, Jin Ho; Yun, Kyoung In; Park, In Woo; Choi, Hang Moon; Park, Moon Soo

    2006-01-01

    The purpose of this study was to elevate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P>0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change

  16. Comparison of static MRI and pseudo-dynamic MRI in temporomandibular joint disorder patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Ho; Yun, Kyoung In [Eulji Univ. School of Medicine, Seoul (Korea, Republic of); Park, In Woo; Choi, Hang Moon; Park, Moon Soo [Kangnung National Univ. College of Dentistry, Kangnung (Korea, Republic of)

    2006-12-15

    The purpose of this study was to elevate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P>0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  17. Journal: A Review of Some Tracer-Test Design Equations for ...

    Science.gov (United States)

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estimation equations are reviewed here, 32 of which were evaluated using previously published tracer-test design examination parameters. Comparison of the results produced a wide range of estimated tracer mass, but no means is available by which one equation may be reasonably selected over the others. Each equation produces a simple approximation for tracer mass. Most of the equations are based primarily on estimates or measurements of discharge, transport distance, and suspected transport times. Although the basic field parameters commonly employed are appropriate for estimating tracer mass, the 33 equations are problematic in that they were all probably based on the original developers' experience in a particular field area and not necessarily on measured hydraulic parameters or solute-transport theory. Suggested sampling frequencies are typically based primarily on probable transport distance, but with little regard to expected travel times. This too is problematic in that tends to result in false negatives or data aliasing. Simulations from the recently developed efficient hydrologic tracer-test design methodology (EHTD) were compared with those obtained from 32 of the 33 published tracer-

  18. Tracer tests Wairakei

    International Nuclear Information System (INIS)

    McCabe, W.J.; Manning, M.R.; Barry, B.J.

    1980-07-01

    The report summarises the radioactive tracer tests, using iodine-131 and bromine-82, made in the Wairakei geothermal field over the period 1978-80. Injection of tracer into three wells with strong cool water downflows at about 300-400m below ground level, produced strong rapid responses from the only deep wells feeding from about 800-1000m and lying in the south-westerly direction from the injection wells, i.e. parallel to the fault planes. Shallower wells, even though in some cases much closer to the injection well, reacted much more slowly. Velocities, as measured by peak arrival times, as high as 22m/h over 200m and 11m/h over 650m, were found. The flow patterns for the cool water feeds to the production area are discussed

  19. Use of activable cations as tracers in groundwater hydrology. The case of DTPA-Indium

    International Nuclear Information System (INIS)

    Lumu, Badimbayi Matu.

    1978-01-01

    The possibilities of EDTA, CDTA and DTPA metallic complexes use as activable groundwater, tracers are discussed. Indium, which has good nuclear caracteristics for activation analysis and forms complexes of great stability with polyamino carboxylic acid has been for Laboratory and field studies. For corporative studies, Rhodomine B, a fluorescent tracer have been studied together with Indium complexes. In laboratory retention studies have been carried with In-EDTA, Iodine 131 and Rhodomine B, as tracers and bentonite, zeolite 13X and Dowex-1 and Dowex-50 as sorbents. As field studies, drainage evolution flow and resident time distribution of tracers substances in water, have been carried, under artificial rain conditions realized by aspersion. Results from field studies showed good characteristics of Indium Complexes especially in very absorbent medium (argilaceous limon) where their restitution balance were superior to that of Rhodomine B

  20. Live controls for radioisotope tracer food chain experiments using meiofauna

    International Nuclear Information System (INIS)

    Montagna, P.A.

    1983-01-01

    Formalin poisoned samples are inadequate for measuring the amount of label to be subtracted as control values for certain food chain studies that employ radioactive tracers. In some studies, tracer is added just before incubation to label ''food'' during the feeding study. Commonly, parallel, poisoned incubations are used to distinguish between biotic and abiotic label incorporation. But, a poisoned control does not account for label that could enter a consumer via active transport, epicuticular microfloral uptake, or grazing on labeled, non-food particles. Experiments were performed to test if label uptake is greater in live non-grazing than dead organisms. Marine benthic meiofauna incoporate from 3 to 133 times more tracer when they are alive and not grazing than when they are formalin killed. These results suggest that control experiments with live animals be performed to measure all processes by which label can enter consumers in food chain experiments. (orig.)

  1. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  2. Effect of patient age on accuracy of primary MRI signs of long head of biceps tearing and instability in the shoulder. An MRI-arthroscopy correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Borrero, Camilo G.; Costello, Joanna; Vyas, Dharmesh [University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Bertolet, Marnie [University of Pittsburgh School of Medicine, Pittsburgh, PA (United States)

    2018-02-15

    To determine the effect of patient age on the accuracy of primary MRI signs of long head of biceps (LHB) tendon tearing and instability in the shoulder using arthroscopy as a reference standard. Subjects with MRI studies and subsequent arthroscopy documenting LHB tendon pathology were identified and organized into three age groups (18-40, 41-60, 61-87). Normal and tendinopathic tendons were labeled grade 0, partial tears grade 1 and full tears grade 2. Two radiologists blinded to arthroscopic data graded MRI studies independently. Prevalence of disease, MRI accuracy for outcomes of interest, and inter-reader agreement were calculated. Eighty-nine subjects fulfilled inclusion criteria with 36 grade 0, 36 grade 1 and 17 grade 2 tendons found at arthroscopy. MRI sensitivity, regardless of age, ranged between 67-86% for grade 0, 72-94% for grade 1 and 82-94% for grade 2 tendons. Specificity ranged between 83-96% for grade 0, 75-85% for grade 1 and 99-100% for grade 2 tendons. MRI accuracy for detection of each LHB category was calculated for each age group. MRI was found to be least sensitive for grade 0 and 1 LHB tendons in the middle-aged group with sensitivity between 55-85% for grade 0 and 53-88% for grade 1 tendons. Agreement between MRI readers was moderate with an unweighted kappa statistic of 62%. MRI accuracy was moderate to excellent and agreement between MRI readers was moderate. MRI appears to be less accurate in characterizing lower grades of LHB tendon disease in middle-aged subjects. (orig.)

  3. TRACER - TRACING AND CONTROL OF ENGINEERING REQUIREMENTS

    Science.gov (United States)

    Turner, P. R.

    1994-01-01

    TRACER (Tracing and Control of Engineering Requirements) is a database/word processing system created to document and maintain the order of both requirements and descriptive material associated with an engineering project. A set of hierarchical documents are normally generated for a project whereby the requirements of the higher level documents levy requirements on the same level or lower level documents. Traditionally, the requirements are handled almost entirely by manual paper methods. The problem with a typical paper system, however, is that requirements written and changed continuously in different areas lead to misunderstandings and noncompliance. The purpose of TRACER is to automate the capture, tracing, reviewing, and managing of requirements for an engineering project. The engineering project still requires communications, negotiations, interactions, and iterations among people and organizations, but TRACER promotes succinct and precise identification and treatment of real requirements separate from the descriptive prose in a document. TRACER permits the documentation of an engineering project's requirements and progress in a logical, controllable, traceable manner. TRACER's attributes include the presentation of current requirements and status from any linked computer terminal and the ability to differentiate headers and descriptive material from the requirements. Related requirements can be linked and traced. The program also enables portions of documents to be printed, individual approval and release of requirements, and the tracing of requirements down into the equipment specification. Requirement "links" can be made "pending" and invisible to others until the pending link is made "binding". Individuals affected by linked requirements can be notified of significant changes with acknowledgement of the changes required. An unlimited number of documents can be created for a project and an ASCII import feature permits existing documents to be incorporated

  4. Characterization of eco-friendly fluorescent nanoparticle-doped tracers for environmental sensing

    International Nuclear Information System (INIS)

    Tauro, Flavia; Rapiti, Emiliano; Al-Sharab, Jafar F.; Ubertini, Lucio; Grimaldi, Salvatore; Porfiri, Maurizio

    2013-01-01

    Particle tracers are extensively used in quantitative flow visualization and environmental sensing. In this paper, we provide a thorough characterization of the novel eco-friendly fluorescent particle tracers formulated in Tauro et al. (AIP Adv 3(3): 032108, 2013). The tracers are synthesized from natural beeswax and are functionalized by encapsulating nontoxic fluorophore nanoparticles in the beads’ matrix through an inexpensive thermal procedure. Visibility and durability studies are conducted through a wide array of techniques to investigate the tracers’ surface morphological microfeatures, crystal nature and size, chemical composition, fluorophore incorporation into the beeswax matrix, and fluorescence response under severe settings resembling exposure to natural environments. Our findings demonstrate that fluorescent nanoparticles ranging from 1.51 to 3.73 nm are homogeneously distributed in the superficial layer (12 nm) of the tracers. In addition, fluorescence emissions are observed up to 26 days of continuous exposure of the tracers to high energy radiation. To demonstrate the particles’ use in environmental flow sensing, a set of proof of concept outdoor tests are conducted, in which image analysis tools are utilized for detecting the fluorescent tracers. Experimental results suggest that fluorescent microparticles deployed in high flow-rate flows (2 m/s) and under direct sunlight can be sensed through commercially available cameras (frame rate set to 30 Hz)

  5. Cortical language activation in aphasia: a functional MRI study

    International Nuclear Information System (INIS)

    Xu Xiaojun; Zhang Minming; Shang Desheng; Wang Qidong; Luo Benyan

    2004-01-01

    Objective: To investigate the differences of the underlying neural basis of language processing between normal subjects and aphasics, and to study the feasibility for functional magnetic resonance imaging (fMRI) in examining the cortical language activation in clinical aphasics. Methods: fMRI was used to map language network in 6 normal subjects and 3 patients with aphasia who were in the stage of recovery from acute stroke. The participants performed word generation task during fMRI scanning, which measured the signal changes associated with regional neural activity induced by the task. These signal changes were processed to statistically generate the activation map that represented the language area. Results: In normal subjects, a distributed language network was activated. Activations were present in the frontal, temporal, parietal and occipital regions in normal group. In the patient group, however, no activation was showed in the left inferior frontal gyrus whether or not the patient had lesion in the left frontal lobe. Two patients showed activations in some right hemisphere regions where no activation appeared in normal subjects. Conclusion: The remote effect of focal lesion and functional redistribution or reorganization was found in aphasic patients. fMRI was useful in evaluating the language function in aphasic patients. (authors)

  6. Comparison of human septal nuclei MRI measurements using automated segmentation and a new manual protocol based on histology

    Science.gov (United States)

    Butler, Tracy; Zaborszky, Laszlo; Pirraglia, Elizabeth; Li, Jinyu; Wang, Xiuyuan Hugh; Li, Yi; Tsui, Wai; Talos, Delia; Devinsky, Orrin; Kuchna, Izabela; Nowicki, Krzysztof; French, Jacqueline; Kuzniecky, Rubin; Wegiel, Jerzy; Glodzik, Lidia; Rusinek, Henry; DeLeon, Mony J.; Thesen, Thomas

    2014-01-01

    Septal nuclei, located in basal forebrain, are strongly connected with hippocampi and important in learning and memory, but have received limited research attention in human MRI studies. While probabilistic maps for estimating septal volume on MRI are now available, they have not been independently validated against manual tracing of MRI, typically considered the gold standard for delineating brain structures. We developed a protocol for manual tracing of the human septal region on MRI based on examination of neuroanatomical specimens. We applied this tracing protocol to T1 MRI scans (n=86) from subjects with temporal epilepsy and healthy controls to measure septal volume. To assess the inter-rater reliability of the protocol, a second tracer used the same protocol on 20 scans that were randomly selected from the 72 healthy controls. In addition to measuring septal volume, maximum septal thickness between the ventricles was measured and recorded. The same scans (n=86) were also analysed using septal probabilistic maps and Dartel toolbox in SPM. Results show that our manual tracing algorithm is reliable, and that septal volume measurements obtained via manual and automated methods correlate significantly with each other (pautomated methods detected significantly enlarged septal nuclei in patients with temporal lobe epilepsy in accord with a proposed compensatory neuroplastic process related to the strong connections between septal nuclei and hippocampi. Septal thickness, which was simple to measure with excellent inter-rater reliability, correlated well with both manual and automated septal volume, suggesting it could serve as an easy-to-measure surrogate for septal volume in future studies. Our results call attention to the important though understudied human septal region, confirm its enlargement in temporal lobe epilepsy, and provide a reliable new manual delineation protocol that will facilitate continued study of this critical region. PMID:24736183

  7. Study of the mineralization of coral implanted in vivo by radioactive tracers

    International Nuclear Information System (INIS)

    Irigaray, J.L.; Sauvage, T.; Oudadesse, H.; El Fadl, H.

    1993-01-01

    Coral may be used as a substitution biomaterial to the bone graft, due to its physico-chemical and architectural properties. The coral, after its implantation 'in vivo' reaches a mineral composition and crystalline structure comparable to those of a bone. The calcification mechanism of this implant is studied using 45 Ca as radioactive tracer. The atomic elements contained in the initial coral were analysed in function of the time spent in the body, by marking the calcium and the strontium contained in its structure. (K.A.) 8 refs.; 6 figs.; 4 tabs

  8. 26Al tracer experiment by accelerator mass spectrometry and its application to the studies for amyotrophic lateral sclerosis and Alzheimer's disease, 1

    International Nuclear Information System (INIS)

    Kobayashi, Koichi; Yumoto, Sakae; Nagai, Hisao; Hosoyama, Yoshiyuki; Imamura, Mineo; Masuzawa, Shin-ichirou; Koizumi, Yoshinobu; Yamashita, Hiroshi.

    1990-01-01

    Accelerator mass spectrometry (AMS) was applied for 26 Al tracer experiment to study the aluminum toxicity and metabolism in rats. To investigate the cause of amyotrophic lateral sclerosis (ALS) and Alzheimer's disease, the aluminum incorporation into the brain (cerebrum) was studied by AMS using 26 Al as a tracer. When 26 Al was intraperitoneally injected into rats, a considerable amount of 26 Al was incorporated into the cerebrum after 5-35 days of the injection. (author)

  9. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  10. Study of solid and liquid behavior in large copper flotation cells (130 m2) using radioactive tracers

    International Nuclear Information System (INIS)

    Diaz, F.; Jimenez, O.; Yianatos, J.; Contreras, F.

    2013-01-01

    The behavior of the solid and liquid phases, in large flotation cells, was characterized by means of the radioactive tracer technique. The use of radioactive tracers enabled the identification of the Residence Time Distribution, of floatable and non-floatable solid, from continuous (on-line) measuring at the output streams of the flotation cells. For this study, the proper radioactive tracers were selected and applied in order to characterize the different phases; i.e. for liquid phase Br-82 as Ammonium Bromide, for floatable solid recovered in the concentrate Cu-64, and for non-floatable solid in three particle size classes (coarse: >150 μm, intermediate: 45 μm, and fine: <45 μm), Na-24. The experimental results confirmed the strong effect of particle size on the Residence Time Distribution, and mean residence time of solids in larger flotation cells, and consequently in flotation hydrodynamics. From a hydrodynamic point of view, the experimental data confirmed that a single mechanical flotation cells, of large size, can deviate significantly from perfect mixing. The experimental work was developed in a 130 m3 industrial flotation cell of the rougher circuit at El Teniente Division, Codelco-Chile. (authors)

  11. Fluorescence guided surgery and tracer-dose, fact or fiction?

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Olmos, Renato A.V.; Bunschoten, Anton; Berg, Nynke S. van den; Klop, W.M.C.; Horenblas, Simon; Poel, Henk G. van der; Wester, Hans-Juergen; Leeuwen, Fijs W.B. van

    2016-01-01

    Fluorescence guidance is an upcoming methodology to improve surgical accuracy. Challenging herein is the identification of the minimum dose at which the tracer can be detected with a clinical-grade fluorescence camera. Using a hybrid tracer such as indocyanine green (ICG)- 99m Tc-nanocolloid, it has become possible to determine the accumulation of tracer and correlate this to intraoperative fluorescence-based identification rates. In the current study, we determined the lower detection limit of tracer at which intraoperative fluorescence guidance was still feasible. Size exclusion chromatography (SEC) provided a laboratory set-up to analyze the chemical content and to simulate the migratory behavior of ICG-nanocolloid in tissue. Tracer accumulation and intraoperative fluorescence detection findings were derived from a retrospective analysis of 20 head-and-neck melanoma patients, 40 penile and 20 prostate cancer patients scheduled for sentinel node (SN) biopsy using ICG- 99m Tc-nanocolloid. In these patients, following tracer injection, single photon emission computed tomography fused with computed tomography (SPECT/CT) was used to identify the SN(s). The percentage injected dose (% ID), the amount of ICG (in nmol), and the concentration of ICG in the SNs (in μM) was assessed for SNs detected on SPECT/CT and correlated with the intraoperative fluorescence imaging findings. SEC determined that in the hybrid tracer formulation, 41 % (standard deviation: 12 %) of ICG was present in nanocolloid-bound form. In the SNs detected using fluorescence guidance a median of 0.88 % ID was present, compared to a median of 0.25 % ID in the non-fluorescent SNs (p-value < 0.001). The % ID values could be correlated to the amount ICG in a SN (range: 0.003-10.8 nmol) and the concentration of ICG in a SN (range: 0.006-64.6 μM). The ability to provide intraoperative fluorescence guidance is dependent on the amount and concentration of the fluorescent dye accumulated in the lesion(s) of

  12. Extended application of radon as a natural tracer in oil reservoirs

    Directory of Open Access Journals (Sweden)

    Moreira R.M.

    2013-05-01

    Full Text Available In the 80's it was a common practice in the study of contamination by NAPL to incorporate a tracer to the medium to be studied. At that time the first applications focused on the use of 222Rn, a naturally occurring radioactive isotope as a natural tracer, appropriate for thermodynamics studies, geology and transport properties in thermal reservoirs. In 1993 the deficit of radon was used to spot and quantify the contamination by DNAPL under the surface. For the first time these studies showed that radon could be used as a partitioning tracer. A methodology that provides alternatives to quantify the oil volume stored in the porous space of oil reservoirs is under development at CDTN. The methodology here applied, widens up and adapts the knowledge acquired from the use of radon as a tracer to the studies aimed at assessing SOR. It is a postulation of this work that once the radon partition coefficient between oil and water is known, SOR will be determined considering the increased amount of radon in the water phase as compared to the amount initially existent as the reservoir is flooded with water. This paper will present a description of the apparatus used and some preliminary results of the experiments.

  13. The power of using functional fMRI on small rodents to study brain pharmacology and disease

    OpenAIRE

    Jonckers, Elisabeth; Shah, Disha; Hamaide, Julie; Verhoye, Marleen; Van der Linden, Annemie

    2015-01-01

    Abstract: Functional magnetic resonance imaging (fMRI) is an excellent tool to study the effect of pharmacological modulations on brain function in a non-invasive and longitudinal manner. We introduce several blood oxygenation level dependent (BOLD) fMRI techniques, including resting state (rsfMRI), stimulus-evoked (st-fMRI), and pharmacological MRI (phMRI). Respectively, these techniques permit the assessment of functional connectivity during rest as well as brain activation triggered by sen...

  14. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian; Cathles, Lawrence M.; Archer, Lynden A.

    2014-01-01

    the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles

  15. Tracers of cancer cells in nuclear oncology

    International Nuclear Information System (INIS)

    Tamgac, F.; Baillet, G.; Moretti, J.L.; Safi, N.; Weinmann, P.; Beco, V. de

    1997-01-01

    Evaluating the extent of disease is important in planning cancer treatment. Different types of tracers are used in vivo to diagnose tumors and these tracers can give supplementary information on the differentiation degree of tumors and response to therapy. (authors)

  16. 15N tracer techniques in pediatric research

    International Nuclear Information System (INIS)

    Heine, W.; Richter, I.; Plath, C.; Wutzke, K.; Stolpe, H.J.; Tiess, M.; Toewe, J.

    1983-01-01

    The main topics of the review comprise mathematical fundamentals of the determination of N metabolism parameters using the 3-pool method, the value of different 15 N tracer substances for the determination of whole-body protein parameters, the utilization of parenterally applied D-amino acids, studies on the influence of different diets on the N metabolism of premature infants with the 15 N tracer technique, the application of the 15 N-glycine-STH-test for the evaluation of the therapeutic effect of STH in children suffering from hypothalamico-hypophyseal dwarfism, in vivo studies on urea utilization by the infant intestinal flora under various dietary regimens as well as in vitro investigations on the utilization of 15 N-labelled urea and NH 4 Cl, resp., by the intestinal flora

  17. Functional Topography of Human Corpus Callosum: An fMRI Mapping Study

    OpenAIRE

    Fabri, Mara; Polonara, Gabriele

    2013-01-01

    The concept of a topographical map of the corpus callosum (CC) has emerged from human lesion studies and from electrophysiological and anatomical tracing investigations in other mammals. Over the last few years a rising number of researchers have been reporting functional magnetic resonance imaging (fMRI) activation in white matter, particularly the CC. In this study the scope for describing CC topography with fMRI was explored by evoking activation through simple sensory stimulation and moto...

  18. Design and rationale for examining neuroimaging genetics in ischemic stroke: The MRI-GENIE study.

    Science.gov (United States)

    Giese, Anne-Katrin; Schirmer, Markus D; Donahue, Kathleen L; Cloonan, Lisa; Irie, Robert; Winzeck, Stefan; Bouts, Mark J R J; McIntosh, Elissa C; Mocking, Steven J; Dalca, Adrian V; Sridharan, Ramesh; Xu, Huichun; Frid, Petrea; Giralt-Steinhauer, Eva; Holmegaard, Lukas; Roquer, Jaume; Wasselius, Johan; Cole, John W; McArdle, Patrick F; Broderick, Joseph P; Jimenez-Conde, Jordi; Jern, Christina; Kissela, Brett M; Kleindorfer, Dawn O; Lemmens, Robin; Lindgren, Arne; Meschia, James F; Rundek, Tatjana; Sacco, Ralph L; Schmidt, Reinhold; Sharma, Pankaj; Slowik, Agnieszka; Thijs, Vincent; Woo, Daniel; Worrall, Bradford B; Kittner, Steven J; Mitchell, Braxton D; Rosand, Jonathan; Golland, Polina; Wu, Ona; Rost, Natalia S

    2017-10-01

    To describe the design and rationale for the genetic analysis of acute and chronic cerebrovascular neuroimaging phenotypes detected on clinical MRI in patients with acute ischemic stroke (AIS) within the scope of the MRI-GENetics Interface Exploration (MRI-GENIE) study. MRI-GENIE capitalizes on the existing infrastructure of the Stroke Genetics Network (SiGN). In total, 12 international SiGN sites contributed MRIs of 3,301 patients with AIS. Detailed clinical phenotyping with the web-based Causative Classification of Stroke (CCS) system and genome-wide genotyping data were available for all participants. Neuroimaging analyses include the manual and automated assessments of established MRI markers. A high-throughput MRI analysis pipeline for the automated assessment of cerebrovascular lesions on clinical scans will be developed in a subset of scans for both acute and chronic lesions, validated against gold standard, and applied to all available scans. The extracted neuroimaging phenotypes will improve characterization of acute and chronic cerebrovascular lesions in ischemic stroke, including CCS subtypes, and their effect on functional outcomes after stroke. Moreover, genetic testing will uncover variants associated with acute and chronic MRI manifestations of cerebrovascular disease. The MRI-GENIE study aims to develop, validate, and distribute the MRI analysis platform for scans acquired as part of clinical care for patients with AIS, which will lead to (1) novel genetic discoveries in ischemic stroke, (2) strategies for personalized stroke risk assessment, and (3) personalized stroke outcome assessment.

  19. Chemotherapeutic agent and tracer composition and use thereof

    International Nuclear Information System (INIS)

    Babb, A. L.

    1985-01-01

    A therapeutic composition suitable for extracorporeal treatment of whole blood comprises a dialyzable chemotherapeutic agent and a dialyzable fluorescable tracer means. The removal rate of the fluorescable tracer compound from treated blood during hemodialysis is a function of the removal rate of unreacted chemotherapeutic agent present. The residual chemotherapeutic agent concentration after hemodialysis is ascertained by measuring the concentration of the fluorescable tracer compound in a dialysate using fluorometric techniques

  20. Synthesis of tracers using automated radiochemistry and robotics

    International Nuclear Information System (INIS)

    Dannals, R.F.

    1992-07-01

    Synthesis of high specific activity radiotracers labeled with short-lived positron-emitting radionuclides for positron emission tomography (PET) often requires handling large initial quantities of radioactivity. High specific activities are required when preparing tracers for use in PET studies of neuroreceptors. A fully automated approach for tracer synthesis is highly desirable. This proposal involves the development of a system for the Synthesis of Tracers using Automated Radiochemistry and Robotics (STARR) for this purpose. While the long range objective of the proposed research is the development of a totally automated radiochemistry system for the production of major high specific activity 11 C-radiotracers for use in PET, the specific short range objectives are the automation of 11 C-methyl iodide ( 11 CH 3 I) production via an integrated approach using both radiochemistry modular labstations and robotics, and the extension of this automated capability to the production of several radiotracers for PET (initially, 11 C-methionine, 3-N-[ 11 C-methyl]spiperone, and [ 11 C]-carfentanil)

  1. Use of a variable tracer infusion method to determine glucose turnover in humans

    International Nuclear Information System (INIS)

    Molina, J.M.; Baron, A.D.; Edelman, S.V.; Brechtel, G.; Wallace, P.; Olefsky, J.M.

    1990-01-01

    The single-compartment pool fraction model, when used with the hyperinsulinemic glucose clamp technique to measure rates of glucose turnover, sometimes underestimates true rates of glucose appearance (Ra) resulting in negative values for hepatic glucose output (HGO). We focused our attention on isotope discrimination and model error as possible explanations for this underestimation. We found no difference in [3-3H] glucose specific activity in samples obtained simultaneously from the femoral artery and vein (2,400 +/- 455 vs. 2,454 +/- 522 dpm/mg) in 6 men during a hyperinsulinemic euglycemic clamp study where insulin was infused at 40 mU.m-2.min-1 for 3 h; therefore, isotope discrimination did not occur. We compared the ability of a constant (0.6 microCi/min) vs. variable tracer infusion method (tracer added to the glucose infusate) to measure non-steady-state Ra during hyperinsulinemic clamp studies. Plasma specific activity fell during the constant tracer infusion studies but did not change from base line during the variable tracer infusion studies. By maintaining a constant plasma specific activity the variable tracer infusion method eliminates uncertainty about changes in glucose pool size. This overcame modeling error and more accurately measures non-steady-state Ra (P less than 0.001 by analysis of variance vs. constant infusion method). In conclusion, underestimation of Ra determined isotopically during hyperinsulinemic clamp studies is largely due to modeling error that can be overcome by use of the variable tracer infusion method. This method allows more accurate determination of Ra and HGO under non-steady-state conditions

  2. PET tracers for somatostatin receptor imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    Johnbeck, Camilla Bardram; Knigge, Ulrich; Kjær, Andreas

    2014-01-01

    Neuroendocrine tumors have shown rising incidence mainly due to higher clinical awareness and better diagnostic tools over the last 30 years. Functional imaging of neuroendocrine tumors with PET tracers is an evolving field that is continuously refining the affinity of new tracers in the search...... these PET tracers further....

  3. Biological tracer for waste site characterization

    International Nuclear Information System (INIS)

    Strong-Gunderson, J.

    1995-01-01

    Remediating hazardous waste sites requires detailed site characterization. In groundwater remediation, characterizing the flow paths and velocity is a major objective. Various tracers have been used for measuring groundwater velocity and transport of contaminants, colloidal particles, and bacteria and nutrients. The conventional techniques use dissolved solutes, dyes. and gases to estimate subsurface transport pathways. These tracers can provide information on transport and diffusion into the matrix, but their estimates for groundwater flow through fractured regions are very conservative. Also, they do not have the same transport characteristics as bacteria and suspended colloid tracers, both of which must be characterized for effective in-place remediation. Bioremediation requires understanding bacterial transport and nutrient distribution throughout the acquifer, knowledge of contaminants s mobile colloidal particles is just essential

  4. MRI Compatibility of Robot Actuation Techniques – A Comparative Study

    Science.gov (United States)

    Fischer, Gregory S.; Krieger, Axel; Iordachita, Iulian; Csoma, Csaba; Whitcomb, Louis L.; Fichtinger, Gabor

    2010-01-01

    This paper reports an experimental evaluation of the following three different MRI-compatible actuators: a Shinsei ultrasonic motor, a Nanomotion ultrasonic motor and a pneumatic cylinder actuator. We report the results of a study comparing the effect of these actuators on the signal to noise ratio (SNR) of MRI images under a variety of experimental conditions. Evaluation was performed with the controller inside and outside the scanner room and with both 1.5T and 3T MRI scanners. Pneumatic cylinders function with no loss of SNR with controller both inside and outside of the scanner room. The Nanomotion motor performs with moderate loss of SNR when moving during imaging. The Shinsei is unsuitable for motion during imaging. All may be used when motion is appropriately interleaved with imaging cycles. PMID:18982643

  5. Fluorescence tracers as a reference for pesticide transport in wetland systems

    Science.gov (United States)

    Lange, Jens; Passeport, Elodie; Tournebize, Julien

    2010-05-01

    Two different fluorescent tracers, Uranine (UR) and Sulforhodamine (SRB), were injected as a pulse into surface flow wetlands. Tracer breakthrough curves were used to document hydraulic efficiencies, peak attenuation and retention capacities of completely different wetland systems. The tracers were used as a reference to mimic photolytic decay (UR) and sorption (SRB) of contaminants, since a real herbicide (Isoproturon, IPU) was injected in parallel to UR and SRB. Analysis costs limited IPU sampling frequency and single samples deviated from the tracer breakthrough curves. Still, a parallel behavior of IPU and SRB could be observed in totally different wetland systems, including underground passage through drainage lines. Similar recovery rates for IPU and SRB confirmed this observation. Hence, SRB was found to be an appropriate reference tracer to mimic the behavior of mobile pesticides (low KOC, without degradation) in wetland systems and the obtained wetland characteristics for SRB may serve as an indication for contaminant retention. Owing to the properties of IPU, the obtained results should be treated as worst case scenarios for highly mobile pesticides. A comparison of six different wetland types suggested that non-steady wetland systems with large variation in water level may temporally store relatively large amounts of tracers (contaminants), partly in areas that are not continuously saturated. This may lead to an efficient attenuation of peak concentrations. However, when large parts of these systems are flushed by natural storm events, tracers (contaminants) may be re-mobilized. In steady systems vegetation density and water depth were found to be the most important factors for tracer/contaminant retention. Illustrated by SRB, sorption on sediments and vegetation was a quick, almost instantaneous process which lead to considerable tracer losses even at high flow velocities and short contact times. Shallow systems with dense vegetation appeared to be the

  6. An Australian population study of factors associated with MRI patterns in cerebral palsy.

    Science.gov (United States)

    Reid, Susan M; Dagia, Charuta D; Ditchfield, Michael R; Carlin, John B; Meehan, Elaine M; Reddihough, Dinah S

    2014-02-01

    The aim of this study was to describe the distribution of magnetic resonance imaging (MRI) patterns in a large population sample of children with cerebral palsy (CP) and to examine associations between MRI patterns, and antenatal and perinatal variables. Data were retrieved from the Victorian CP Register for 884 children (527 males, 357 females) born between 1999 and 2006. Postneonatal MRI was classified for 594 children. For 563 children (329 males, 234 females) for whom classification was to a single MRI pattern, the frequency of each variable was compared between patterns and with the population frequency. White matter injury was the most common MRI pattern (45%), followed by grey matter injury (14%), normal imaging (13%), malformations (10%), focal vascular insults (9%), and miscellaneous patterns (7%). Parity, birth gestation, level of neonatal care, Apgar score, and time to established respiration varied between MRI patterns (ppatterns, future exploration of causal pathways might be facilitated when performed in pathogenically defined groups. © 2013 Mac Keith Press.

  7. Tracer applications in oil reservoirs in Brazil

    International Nuclear Information System (INIS)

    Moreira, R.M.; Ferreira Pinto, A.M.

    2004-01-01

    Radiotracer applications in oil reservoirs in Brazil started in 1997 at the request of the State Oil Company (Petrobras) at the Carmoplois oilfield. 1 Ci of HTO was injected in a regular five-spot plot and the results obtained were quite satisfactory. Shortly after this test one other request asked for distinguishing the contribution of different injection wells to a production well. It was then realized that other tracers should be available. As a first choice 35 SCN - has been selected since it could be produced at CDTN. An alternative synthesis path was defined which shortened post-irradiation manipulations. The tracer was tested in core samples and a field injection, simultaneously with HTO, was carried out at the Buracica field; again the HTO performed well but 35 SCN - showed up well ahead. Presently the HTO applications are being done on a routine basis. All in all, four tests were performed (some are still ongoing), and the detection limits for both 3 H and 35 S were optimized by refining the sample preparation stage. Lanthanide complexes used as activable tracers are also an appealing option, however core tests performed so far with La-, Ce- and Eu-EDTA indicated some delay of the tracer, so other complexants such as DOTA are to be tried in further laboratory tests and in a field application. Thus, a deeper understanding of their complexation chemistry and carefully conducted tests must be performed before lanthanide complexes can be qualified as reliable oil reservoir tracers. More recently, Petrobras has been asking for partitioning tracers intended for SOR measurement

  8. Transient tracers in the ocean (TTO) program: the North Atlantic study, 1981: the Tropical Atlantic study, 1983

    International Nuclear Information System (INIS)

    Brewer, P.G.; Sarmiento, J.L.; Smethie, W.M. Jr.

    1985-01-01

    The two parts of this major geochemical and physical oceanographic expedition took place on the research vessel Knorr of the Woods Hole Oceanographic Institution. The expeditions were designed to observe the passage of man-made geochemical tracers into the interior of the ocean. A systematic survey revealed the penetration into the thermocline and deep ocean of the products of man's military/industrial activities, principally tritium and carbon-14 resulting from atmospheric testing of nuclear weapons. The passage of these tracers documents as nothing else can the manner and time scale of ocean mixing and provides a fundamental calibration for models of ocean circulation. Maps showing the cruise routes are presented. 1 figure, 1 table

  9. Imaging gait analysis: An fMRI dual task study.

    Science.gov (United States)

    Bürki, Céline N; Bridenbaugh, Stephanie A; Reinhardt, Julia; Stippich, Christoph; Kressig, Reto W; Blatow, Maria

    2017-08-01

    In geriatric clinical diagnostics, gait analysis with cognitive-motor dual tasking is used to predict fall risk and cognitive decline. To date, the neural correlates of cognitive-motor dual tasking processes are not fully understood. To investigate these underlying neural mechanisms, we designed an fMRI paradigm to reproduce the gait analysis. We tested the fMRI paradigm's feasibility in a substudy with fifteen young adults and assessed 31 healthy older adults in the main study. First, gait speed and variability were quantified using the GAITRite © electronic walkway. Then, participants lying in the MRI-scanner were stepping on pedals of an MRI-compatible stepping device used to imitate gait during functional imaging. In each session, participants performed cognitive and motor single tasks as well as cognitive-motor dual tasks. Behavioral results showed that the parameters of both gait analyses, GAITRite © and fMRI, were significantly positively correlated. FMRI results revealed significantly reduced brain activation during dual task compared to single task conditions. Functional ROI analysis showed that activation in the superior parietal lobe (SPL) decreased less from single to dual task condition than activation in primary motor cortex and in supplementary motor areas. Moreover, SPL activation was increased during dual tasks in subjects exhibiting lower stepping speed and lower executive control. We were able to simulate walking during functional imaging with valid results that reproduce those from the GAITRite © gait analysis. On the neural level, SPL seems to play a crucial role in cognitive-motor dual tasking and to be linked to divided attention processes, particularly when motor activity is involved.

  10. Isotopes as tracers of the oceanic circulation: Results from the World Ocean Circulation Experiment

    International Nuclear Information System (INIS)

    Schlosser, P.; Jenkins, W.J.; Key, R.; Lupton, J.

    2002-01-01

    During the past decades, natural and anthropogenic isotopes such as tritium ( 3 H), radiocarbon ( 14 C), 3 He, or the stable isotopes of water have been used in studies of the dynamics of natural systems. Early applications of tracers to studies of the ocean were directed at determination of circulation patterns and mean residence times of specific water masses, as well as estimates of mixing coefficients. These exploratory studies suggested that tracers can add significantly to our understanding of the oceanic circulation. In order to fully exploit this potential, the first global tracer study, the GEochemical Ocean SECtions Study (GEOSECS), was launched. From the GEOSECS results it was immediately apparent that very close coordination of tracer programs with physical oceanography studies is required for full utilization of tracer data. During the 1980s plans for the World OCean Experiment (WOCE) were developed. As part of its Hydrographic Program (WHP), especially during the one-time survey, a set of tracers were measured on a global scale with unprecedented spatial resolution (both lateral and vertical). The original plan included a larger number of tracers (CFCs, 3 H/ 3 He, 14 C, 39 Ar, stable isotopes of water, helium isotopes, 228 Ra, 90 Sr, 137 Cs, 85 Kr) than could actually be measured systematically (CFCs, 3 H/ 3 He, 14 C, H 2 18 O/H 2 16 O, helium isotopes). Nevertheless, the resulting data set, which presently is under evaluation, exceeds those obtained from pre-WOCE tracer studies by a wide margin. In this contribution, we describe the existing WOCE data set and demonstrate the type of results that can be expected from its interpretation on the basis of a few selected examples. These examples include: (1) the application of tritium and 3 He to studies of the ventilation of the upper waters in the Pacific Ocean, (2) the spreading of intermediate water in the Pacific and Indian oceans as derived from the distribution of 3 He, and (3) the evaluation of

  11. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    Science.gov (United States)

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period

  12. Chlorine isotopes potential as geo-chemical tracers

    Digital Repository Service at National Institute of Oceanography (India)

    Shirodkar, P.V.; Pradhan, U.K.; Banerjee, R.

    The potential of chlorine isotopes as tracers of geo-chemical processes of earth and the oceans is highlighted based on systematic studies carried out in understanding the chlorine isotope fractionation mechanism, its constancy in seawater and its...

  13. Development and application of a modified wireless tracer for disaster prevention

    Science.gov (United States)

    Chung Yang, Han; Su, Chih Chiang

    2016-04-01

    Typhoon-induced flooding causes water overflow in a river channel, which results in general and bridge scour and soil erosion, thus leading to bridge failure, debris flow and landslide collapse. Therefore, dynamic measurement technology should be developed to assess scour in channels and landslide as a disaster-prevention measure against bridge failure and debris flow. This paper presents a wireless tracer that enables monitoring general scour in river channels and soil erosion in hillsides. The wireless tracer comprises a wireless high-power radio modem, various electronic components, and a self-designed printed circuit board that are all combined with a 9-V battery pack and an auto switch. The entire device is sealed in a jar by silicon. After it was modified, the wireless tracer underwent the following tests for practical applications: power continuation and durability, water penetration, and signal transmission during floating. A regression correlation between the wireless tracer's transmission signal and distance was also established. This device can be embedded at any location where scouring is monitored, and, in contrast to its counterparts that detect scour depth by identifying and analyzing received signals, it enables real-time observation of the scouring process. In summary, the wireless tracer developed in this study provides a dynamic technology for real-time monitoring of scouring (or erosion) and forecasting of landslide hazards. Keywords: wireless tracer; scour; real-time monitoring; landslide hazard.

  14. An uncertainty inclusive un-mixing model to identify tracer non-conservativeness

    Science.gov (United States)

    Sherriff, Sophie; Rowan, John; Franks, Stewart; Fenton, Owen; Jordan, Phil; hUallacháin, Daire Ó.

    2015-04-01

    Sediment fingerprinting is being increasingly recognised as an essential tool for catchment soil and water management. Selected physico-chemical properties (tracers) of soils and river sediments are used in a statistically-based 'un-mixing' model to apportion sediment delivered to the catchment outlet (target) to its upstream sediment sources. Development of uncertainty-inclusive approaches, taking into account uncertainties in the sampling, measurement and statistical un-mixing, are improving the robustness of results. However, methodological challenges remain including issues of particle size and organic matter selectivity and non-conservative behaviour of tracers - relating to biogeochemical transformations along the transport pathway. This study builds on our earlier uncertainty-inclusive approach (FR2000) to detect and assess the impact of tracer non-conservativeness using synthetic data before applying these lessons to new field data from Ireland. Un-mixing was conducted on 'pristine' and 'corrupted' synthetic datasets containing three to fifty tracers (in the corrupted dataset one target tracer value was manually corrupted to replicate non-conservative behaviour). Additionally, a smaller corrupted dataset was un-mixed using a permutation version of the algorithm. Field data was collected in an 11 km2 river catchment in Ireland. Source samples were collected from topsoils, subsoils, channel banks, open field drains, damaged road verges and farm tracks. Target samples were collected using time integrated suspended sediment samplers at the catchment outlet at 6-12 week intervals from July 2012 to June 2013. Samples were dried (affected whereas uncertainty was only marginally impacted by the corrupted tracer. Improvement of uncertainty resulted from increasing the number of tracers in both the perfect and corrupted datasets. FR2000 was capable of detecting non-conservative tracer behaviour within the range of mean source values, therefore, it provided a more

  15. Cognitive dissonance induction in everyday life: An fMRI study.

    Science.gov (United States)

    de Vries, Jan; Byrne, Mark; Kehoe, Elizabeth

    2015-01-01

    This functional magnetic resonance imaging (fMRI) study explored the neural substrates of cognitive dissonance during dissonance "induction." A novel task was developed based on the results of a separate item selection study (n = 125). Items were designed to generate dissonance by prompting participants to reflect on everyday personal experiences that were inconsistent with values they had expressed support for. One experimental condition (dissonance) and three control conditions (justification, consonance, and non-self-related inconsistency) were used for comparison. Items of all four types were presented to each participant (n = 14) in a randomized design. The fMRI analysis used a whole-brain approach focusing on the moments dissonance was induced. Results showed that in comparison with the control conditions the dissonance experience led to higher levels of activation in several brain regions. Specifically dissonance was associated with increased neural activation in key brain regions including the anterior cingulate cortex (ACC), anterior insula, inferior frontal gyrus, and precuneus. This supports current perspectives that emphasize the role of anterior cingulate and insula in dissonance processing. Less extensive activation in the prefrontal cortex than in some previous studies is consistent with this study's emphasis on dissonance induction, rather than reduction. This article also contains a short review and comparison with other fMRI studies of cognitive dissonance.

  16. Benefits of important industrial tracer applications in the GDR

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Goeldner, R.; Koennecke, H.G.; Kupsch, H.; Luther, D.; Otto, R.; Reinhardt, R.; Ulrich, H.

    1990-01-01

    Tracers can be used to label substances or objects in order to discriminate between them, to follow their movement, to record changes of concentration and distribution between phases, etc. The main advantages of tracer investigations are the contactless recording of signals without influencing the observed process (also under rigorous operation conditions), the high detection sensitivity, the large number of available tracer nuclides (problems of all branches of industry can be solved) and the fact that tracer investigation can be carried out on operating production units, so that they provide valuable checks of the validity of design and process data. The cost-to-benefit ratio can be as low as 1:50. In the following some selected examples of tracer applications and their benefits will be presented. (orig./BBR) [de

  17. INTRAVAL Finnsjoen Test - modelling results for some tracer experiments

    International Nuclear Information System (INIS)

    Jakob, A.; Hadermann, J.

    1994-09-01

    This report presents the results within Phase II of the INTRAVAL study. Migration experiments performed at the Finnsjoen test site were investigated. The study was done to gain an improved understanding of not only the mechanisms of tracer transport, but also the accuracy and limitations of the model used. The model is based on the concept of a dual porosity medium, taking into account one dimensional advection, longitudinal dispersion, sorption onto the fracture surfaces, diffusion into connected pores of the matrix rock, and sorption onto matrix surfaces. The number of independent water carrying zones, represented either as planar fractures or tubelike veins, may be greater than one, and the sorption processes are described either by linear or non-linear Freundlich isotherms assuming instantaneous sorption equilibrium. The diffusion of the tracer out of the water-carrying zones into connected pore space of the adjacent rock is calculated perpendicular to the direction of the advective/dispersive flow. In the analysis, the fluid flow parameters are calibrated by the measured breakthrough curves for the conservative tracer (iodide). Subsequent fits to the experimental data for the two sorbing tracers strontium and cesium then involve element dependent parameters providing information on the sorption processes and on its representation in the model. The methodology of fixing all parameters except those for sorption with breakthrough curves for non-sorbing tracers generally worked well. The investigation clearly demonstrates the necessity of taking into account pump flow rate variations at both boundaries. If this is not done, reliable conclusions on transport mechanisms or geometrical factors can not be achieved. A two flow path model reproduces the measured data much better than a single flow path concept. (author) figs., tabs., 26 refs

  18. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B; Michel, Christian J; El Fakhri, Georges; Schmand, Matthias; Sorensen, A Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI

  19. MRI STUDY OF TYPES AND INCIDENCE OF INTERNAL DERANGEMENTS OF TRAUMATIC KNEE JOINT

    Directory of Open Access Journals (Sweden)

    Bomidi Sudha Rani

    2016-12-01

    Full Text Available BACKGROUND MRI has been accepted as the best imaging modality for noninvasive evaluation of knee injuries and it has proved reliable, safe and offers advantages over diagnostic arthroscopy, which is currently regarded as the reference standard for the diagnosis of internal derangements of the knee. 1 METHODS AND MATERIALS A prospective study of fifty patients who underwent MRI for the diagnosis of internal derangement of knee was conducted between the period of January 2015 to January 2016 in Government General Hospital, Kakinada. All the patients with history of knee joint pain following trauma and clinically suspected to have meniscal and ligament tears are included in the study. Patients were evaluated using GE 1.5 T MRI machine with pulsar gradient system using a sensor extremity coil. RESULTS Commonest lesion detected in our study was ACL tear followed by medial meniscal tear and medial collateral ligament injury. The most common sign of cruciate ligament injury was hyperintensity in the ligament. Grade 3 was the most common grade of meniscal tear. CONCLUSION MRI is an excellent, noninvasive, radiation free imaging modality and is unique in its ability to evaluate the internal structure as well as soft tissue delineation. Many anatomical variants can mimic a tear on MRI. MRI is an excellent noninvasive modality for imaging the knee and helps in arriving at a correct anatomical diagnosis there by guiding further management of the patient.

  20. Multi-Tracer Approach for Shelf Water Mixing Studies in Brazilian Regions under Different Climates

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, L. D.; Marins, R. V.; Dias, F. J.S. [Instituto de Ciencias do Mar, Universidate Federal do Ceara, Fortaleza, CE (Brazil); Godoy, M. L.D.P. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Rio de Janeiro, RJ (Brazil); Godoy, J. M.; Souza, T. A. [Departamento de Quimica, Pontificia Universidade Catolica, Rio de Janeiro, RJ (Brazil); Rezende, C. E. [Centro de Biociencias e Biotecnologia, Universidade Estadual do Norte Fluminense, Campos dos Goytacazes, RJ (Brazil)

    2013-07-15

    Fresh water and sediment supply at estuary and plume regions has dramatically changed due to land use changes, mostly damming, in river basins. The resulting impact, however, may vary significantly depending on climate and hydrology. The seasonal differences in shelf, plume, estuarine and river waters of two watersheds located under contrasting climates in the Brazilian coast are reported using a multi-tracer approach (salinity, barium, silica, uranium, deuterium and {sup 18}O) to characterize the mixing processes. At the Paraiba do Sul River, SE Brazil, in a wet tropical coast, all results showed similarity between dry and wet seasons; at the Jaguaribe river under semi arid climate in NE Brazil, the results showed a moving freshwater plume depending on season, with freshwater at the estuary in the rainy season and shelf water intrusion upstream in the estuary in the dry season. Most tracers used were able to consistently characterize water masses even in the wide range of latitudes studied, confirming their importance as a tool for modelling mixing processes at the continent-ocean boundary. Barium, however, still needs better studies on its seashore chemistry, since in the semi arid site, Ba distribution could not be directly related to conservative mixing behaviour, at least during the rainy season. (author)

  1. Comparison of thermal, salt and dye tracing to estimate shallow flow velocities: Novel triple-tracer approach

    Science.gov (United States)

    Abrantes, João R. C. B.; Moruzzi, Rodrigo B.; Silveira, Alexandre; de Lima, João L. M. P.

    2018-02-01

    The accurate measurement of shallow flow velocities is crucial to understand and model the dynamics of sediment and pollutant transport by overland flow. In this study, a novel triple-tracer approach was used to re-evaluate and compare the traditional and well established dye and salt tracer techniques with the more recent thermal tracer technique in estimating shallow flow velocities. For this purpose a triple tracer (i.e. dyed-salted-heated water) was used. Optical and infrared video cameras and an electrical conductivity sensor were used to detect the tracers in the flow. Leading edge and centroid velocities of the tracers were measured and the correction factors used to determine the actual mean flow velocities from tracer measured velocities were compared and investigated. Experiments were carried out for different flow discharges (32-1813 ml s-1) on smooth acrylic, sand, stones and synthetic grass bed surfaces with 0.8, 4.4 and 13.2% slopes. The results showed that thermal tracers can be used to estimate shallow flow velocities, since the three techniques yielded very similar results without significant differences between them. The main advantages of the thermal tracer were that the movement of the tracer along the measuring section was more easily visible than it was in the real image videos and that it was possible to measure space-averaged flow velocities instead of only one velocity value, with the salt tracer. The correction factors used to determine the actual mean velocity of overland flow varied directly with Reynolds and Froude numbers, flow velocity and slope and inversely with flow depth and bed roughness. In shallow flows, velocity estimation using tracers entails considerable uncertainty and caution must be taken with these measurements, especially in field studies where these variables vary appreciably in space and time.

  2. National Biomedical Tracer Facility. Project definition study

    International Nuclear Information System (INIS)

    Schafer, R.

    1995-01-01

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research: fast neutrons, thermal neutrons, and particle beams (H - , H + , and D + ). The proposed NBTF facility includes an 80 MeV, 1 mA H - cyclotron that will produce proton-induced (neutron deficient) research isotopes

  3. Integrating fMRI with psychophysiological measurements in the study of decision-making

    OpenAIRE

    Wong, Savio W.H.; Xue, Gui; Bechara, Antoine

    2011-01-01

    Neuroimaging techniques have recently been used to examine the neural mechanism of decision-making. Nevertheless, most of the neuroimaging studies overlook the importance of emotion and autonomic response in modulating the process of decision-making. In this paper, we discussed how to integrating fMRI with psychophysiological measurements in studying decision-making. We suggested that psychophysiological data would complement with fMRI findings in providing a more comprehensive understanding ...

  4. COMPARISON OF THREE TRACER TESTS AT THE RAFT RIVER GEOTHERMAL SITE

    Energy Technology Data Exchange (ETDEWEB)

    Earl D Mattson; Mitchell Plummer; Carl Palmer; Larry Hull; Samantha Miller; Randy Nye

    2011-02-01

    Three conservative tracer tests have been conducted through the Bridge Fault fracture zone at the Raft River Geothermal (RRG) site. All three tests were conducted between injection well RRG-5 and production wells RRG-1 (790 m distance) and RRG-4 (740 m distance). The injection well is used during the summer months to provide pressure support to the production wells. The first test was conducted in 2008 using 136 kg of fluorescein tracer. Two additional tracers were injected in 2010. The first 2010 tracer injected was 100 kg fluorescein disodium hydrate salt on June, 21. The second tracer (100 kg 2,6-naphthalene disulfonic acid sodium salt) was injected one month later on July 21. Sampling of the two productions wells is still being performed to obtain the tail end of the second 2010 tracer test. Tracer concentrations were measured using HPLC with a fluorescence detector. Results for the 2008 test, suggest 80% tracer recover at the two production wells. Of the tracer recovered, 85% of tracer mass was recovered in well RRG-4 indicating a greater flow pathway connection between injection well and RRG-4 than RRG-1. Fluorescein tracer results appear to be similar between the 2008 and 2010 tests for well RRG-4 with peak concentrations arriving approximately 20 days after injection despite the differences between the injection rates for the two tests (~950 gpm to 475 gpm) between the 2008 and 2010. The two 2010 tracer tests will be compared to determine if the results support the hypothesis that rock contraction along the flow pathway due to the 55 oC cooler water injection alters the flow through the ~140 oC reservoir.

  5. Tracer verification and monitoring of containment systems (II)

    International Nuclear Information System (INIS)

    Williams, C.V.; Dunn, S.D.; Lowry, W.E.

    1997-01-01

    A tracer verification and monitoring system, SEAtrace trademark, has been designed and field tested which uses gas tracers to evaluate, verify, and monitor the integrity of subsurface barriers. This is accomplished using an automatic, rugged, autonomous monitoring system combined with an inverse optimization code. A gaseous tracer is injected inside the barrier and an array of wells outside the barrier are monitored. When the tracer gas is detected, a global optimization code is used to calculate the leak parameters, including leak size, location, and when the leak began. The multipoint monitoring system operates in real-time, can be used to measure both the tracer gas and soil vapor contaminants, and is capable of unattended operation for long periods of time (months). The global optimization code searches multi-dimensional open-quotes spaceclose quotes to find the best fit for all of the input parameters. These parameters include tracer gas concentration histories from multiple monitoring points, medium properties, barrier location, and the source concentration. SEAtrace trademark does not attempt to model all of the nuances associated with multi-phase, multi-component flow, but rather, the inverse code uses a simplistic forward model which can provide results which are reasonably accurate. The system has calculated leak locations to within 0.5 meters and leak radii to within 0.12 meters

  6. In vivo longitudinal MRI and behavioral studies in experimental spinal cord injury.

    Science.gov (United States)

    Sundberg, Laura M; Herrera, Juan J; Narayana, Ponnada A

    2010-10-01

    Comprehensive in vivo longitudinal studies that include multi-modal magnetic resonance imaging (MRI) and a battery of behavioral assays to assess functional outcome were performed at multiple time points up to 56 days post-traumatic spinal cord injury (SCI) in rodents. The MRI studies included high-resolution structural imaging for lesion volumetry, and diffusion tensor imaging (DTI) for probing the white matter integrity. The behavioral assays included open-field locomotion, grid walking, inclined plane, computerized activity box performance, and von Frey filament tests. Additionally, end-point histology was assessed for correlation with both the MRI and behavioral data. The temporal patterns of the lesions were documented on structural MRI. DTI studies showed significant changes in white matter that is proximal to the injury epicenter and persisted to day 56. White matter in regions up to 1 cm away from the injury epicenter that appeared normal on conventional MRI also exhibited changes that were indicative of tissue damage, suggesting that DTI is a more sensitive measure of the evolving injury. Correlations between DTI and histology after SCI could not be firmly established, suggesting that injury causes complex pathological changes in multiple tissue components that affect the DTI measures. Histological evidence confirmed a significant decrease in myelin and oligodendrocyte presence 56 days post-SCI. Multiple assays to evaluate aspects of functional recovery correlated with histology and DTI measures, suggesting that damage to specific white matter tracts can be assessed and tracked longitudinally after SCI.

  7. In-situ testing methods using radioactive tracers

    International Nuclear Information System (INIS)

    Sauzay, G.

    1976-01-01

    Some typical applications of tracer techniques in hydrology are presented: study of the extraction of sands and gravels in a estuary; in-situ study of the transport of sediments by the swell at a depth ranging from 8 to 22m; study of the transport of sands on the site Bonne Anse - Saint Palais [fr

  8. An evaluation of an improved method for computing histograms in dynamic tracer studies using positron-emission tomography

    International Nuclear Information System (INIS)

    Ollinger, J.M.; Snyder, D.L.

    1986-01-01

    A method for computing approximate minimum-mean-square-error estimates of histograms from list-mode data for use in dynamic tracer studies is evaluated. Parameters estimated from these histograms are significantly more accurate than those estimated from histograms computed by a commonly used method

  9. Perfusion characteristics of late radiation injury of parotid glands: quantitative evaluation with dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Juan, Chun-Jung; Chen, Cheng-Yu.; Hsueh, Chun-Jen; Huang, Guo-Shu; Jen, Yee-Min; Liu, Hua-Shan; Wang, Chao-Ying; Chung, Hsiao-Wen; Liu, Yi-Jui; Chou, Yu-Ching; Chai, Yao-Te

    2009-01-01

    We aimed to quantitatively investigate the alteration of parotid perfusion after irradiation using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on a two-compartment tracer kinetic model. This study enrolled 19 patients (53.2±14.9 years) treated by head and neck radiotherapy and 19 age-relevant and sex-matched subjects as a control group. Perfusion parameters (K el , k 21 and A) of parotid glands were analyzed based on the Brix model from T1-weighted DCE-MRI. Suitability of the Brix model was evaluated via Monte Carlo simulation for the goodness-of-fit. Analysis of nonlinear goodness-of-fit showed that the Brix model is appropriate in evaluating the parotid perfusion (R 2 = 0.938±0.050). The irradiated parotid glands showed significantly lower K el (P 21 (P < 0.05) and consequently significantly higher value of peak enhancement (P<0.0005) and time-to-peak (P<0.0005) compared with non-irradiated ones, suggestive of gradual and prolonged accumulation and delayed wash-out of contrast agent due to increased extracellular extravascular space and decreased vascular permeability in the irradiated glands. Linear regression analysis showed dose-dependent perfusion changes of the irradiated parotid glands. We conclude that quantitative DCE-MRI is a potential tool in investigating parotid gland perfusion changes after radiotherapy. (orig.)

  10. You are not always what we think you eat. Selective assimilation across multiple whole-stream isotopic tracer studies

    International Nuclear Information System (INIS)

    Dodds, W. K.; Collins, S. M.; Hamilton, S. K.; Johnson, S.; Webster, J. R.; Simon, K. S.; Whiles, M. R.; Rantala, H. M.; McDowell, W. H.; Peterson, S. D.; Riis, T.; Crenshaw, C. L.; Thomas, S. A.; Kristensen, P. B.; Cheever, B. M.; Flecker, A. S.; Griffiths, N. A.; Crowl, T.; Rosi-Marshall, E. J.; El-Sabaawi, R.; Marti, E.

    2014-01-01

    Analyses of 21 15 N stable isotope tracer experiments, designed to examine food web dynamics in streams around the world, indicated that the isotopic composition of food resources assimilated by primary consumers (mostly invertebrates) poorly reflected the presumed food sources. Modeling indicated that consumers assimilated only 33-50% of the N available in sampled food sources such as decomposing leaves, epilithon, and fine particulate detritus over feeding periods of weeks or more. Thus, common methods of sampling food sources consumed by animals in streams do not sufficiently reflect the pool of N they assimilate. Lastly, Isotope tracer studies, combined with modeling and food separation techniques, can improve estimation of N pools in food sources that are assimilated by consumers

  11. Evaporation rate in containers used for storing radioactive tracer solutions

    International Nuclear Information System (INIS)

    Gascon, J.L.

    2002-01-01

    In radiochemical analysis, the storage of a tracer solution is an important issue to bear in mind. The evaporation of the tracer solution depends on the type of container used for storing. Evaporation rate in four kinds of containers, i.e., flame-sealed glass ampoule, sealed glass flask, flame-sealed polyethylene ampoule and screw glass vial was studied. It is concluded that the evaporation rate depends on the system of closing. (author)

  12. Suitable activated stable nuclide tracer technique and its applications in biology and medicine

    International Nuclear Information System (INIS)

    Zhang Weicheng

    1989-01-01

    Stable isotopes as tracers in biology and medicine have been more extensively used. Mass spectrometry has been a classic technique in the analysis of stable isotopes because it is very sensitive and precise. Activation analysis has recently been introduced as an analytical tool. Its fast speed and simplicity is a great advantage for handling large batches of samples in isotopic tracer experiments. The combination of enriched stable isotope tracer studies and activation analysis techniques has become an ideal and reliable technique, especially in the fields of biology and medicine. This paper presents a survey of the fundamental principle, the character and the applications in biology and medicine for the suitable activated stable isotope tracer techniques

  13. Tracer sorption and macroscopic transport in clay nano-pores: a lattice-Boltzmann study

    International Nuclear Information System (INIS)

    Levesque, Maximilien; Rotenberg, Benjamin; Duvail, Magali; Benichou, Olivier; Voituriez, Raphael; Pagonabarraga, Ignacio; Frenkel, Daan

    2012-01-01

    Document available in extended abstract form only. The Agence Nationale pour la gestion des Dechets Radioactifs (ANDRA) has been entrusted to find a safe solution for disposing of existing and future nuclear wastes. A prototype site has been considered for the waste disposal in a deep underground sedimentary geological formation. It is composed of clay minerals chosen, among other reasons, for their remarkable ability to limit radionuclide transport. Clay minerals are complex charged porous media characterized by heterogeneities at several length scales. They naturally occur as an assembly of few nano-meter-sized particles connected to form 10 to 100 nm interparticle pores containing water and ions. This intrinsically multi-scale structure, that gives the material its remarkable properties, makes the description of sorption and transport phenomena of transported ions particularly challenging. Experimental studies of water and ion transport through clays mostly consist in evaluating macroscopic effective transport coefficients like permeability or conductivity. They showed that the main transport mechanism is an effective diffusion that not only depends on particle charge but also on its chemical nature, or specificity. The goal of assessing the performance of clays as confinement barriers, particularly in the context of the geological disposal of nuclear waste, requires not only quantitative prediction of the retention and transport of species but also an understanding of the microscopic mechanisms underlying them. A successful approach has been to use numerical simulations via the Lattice-Boltzmann method (LB). It consists in making evolve populations describing the fluid at a level which is consistent with time and length-scales involved in transport properties, while still including a microscopic description of the phenomena. The transport of charged ions at the pore scale has recently been included in LB. In this method, the evolution of a tracer population is

  14. EEG-fMRI Bayesian framework for neural activity estimation: a simulation study

    Science.gov (United States)

    Croce, Pierpaolo; Basti, Alessio; Marzetti, Laura; Zappasodi, Filippo; Del Gratta, Cosimo

    2016-12-01

    Objective. Due to the complementary nature of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI), and given the possibility of simultaneous acquisition, the joint data analysis can afford a better understanding of the underlying neural activity estimation. In this simulation study we want to show the benefit of the joint EEG-fMRI neural activity estimation in a Bayesian framework. Approach. We built a dynamic Bayesian framework in order to perform joint EEG-fMRI neural activity time course estimation. The neural activity is originated by a given brain area and detected by means of both measurement techniques. We have chosen a resting state neural activity situation to address the worst case in terms of the signal-to-noise ratio. To infer information by EEG and fMRI concurrently we used a tool belonging to the sequential Monte Carlo (SMC) methods: the particle filter (PF). Main results. First, despite a high computational cost, we showed the feasibility of such an approach. Second, we obtained an improvement in neural activity reconstruction when using both EEG and fMRI measurements. Significance. The proposed simulation shows the improvements in neural activity reconstruction with EEG-fMRI simultaneous data. The application of such an approach to real data allows a better comprehension of the neural dynamics.

  15. Compartmental Modeling and Dosimetry of in Vivo Metabolic Studies of Leucine and Three Secretory Proteins in Humans Using Radioactive Tracers

    Science.gov (United States)

    Venkatakrishnan, Vaidehi

    1995-01-01

    Physical and mathematical models provide a systematic means of looking at biological systems. Radioactive tracer kinetic studies open a unique window to study complex tracee systems such as protein metabolism in humans. This research deals with compartmental modeling of tracer kinetic data on leucine and apolipoprotein metabolism obtained using an endogenous tritiated leucine tracer administered as a bolus, and application of compartmental modeling techniques for dosimetric evaluation of metabolic studies of radioiodinated apolipoproteins. Dr. Waldo R. Fisher, Department of Medicine, was the coordinating research supervisor and the work was carried out in his laboratory. A compartmental model for leucine kinetics in humans has been developed that emphasizes its recycling pathways which were examined over two weeks. This model builds on a previously published model of Cobelli et al, that analyzed leucine kinetic data up to only eight hours. The proposed model includes different routes for re-entry of leucine from protein breakdown into plasma accounting for proteins which turn over at different rates. This new model successfully incorporates published models of three secretory proteins: albumin, apoA-I, and VLDL apoB, in toto thus increasing its validity and utility. The published model of apoA-I, based on an exogenous radioiodinated tracer, was examined with data obtained using an endogenous leucine tracer using compartmental techniques. The analysis concludes that the major portion of apoA-I enters plasma by a fast pathway but the major fraction of apoA-I in plasma resides with a second slow pathway; further the study is suggestive of a precursor-product relationship between the two plasma apoA-I pools. The possible relevance of the latter suggestion to the aberrant kinetics of apoA-I in Tangier disease is discussed. The analysis of apoA-II data resulted in similar conclusions. A methodology for evaluating the dosimetry of radioiodinated apolipoproteins by

  16. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  17. Response assessment with the CXCR4-directed positron emission tomography tracer [68Ga]Pentixafor in a patient with extranodal marginal zone lymphoma of the orbital cavities.

    Science.gov (United States)

    Herhaus, Peter; Habringer, Stefan; Vag, Tibor; Steiger, Katja; Slotta-Huspenina, Julia; Gerngroß, Carlos; Wiestler, Benedikt; Wester, Hans-Jürgen; Schwaiger, Markus; Keller, Ulrich

    2017-12-01

    CXCR4 belongs to the family of chemokine receptors. Together with its sole known ligand CXCL12 (SDF-1alpha), it has a pivotal role during organogenesis and for homing of hematopoietic stem cells. CXCR4 is overexpressed in various malignancies, and this is often associated with poor prognosis. Therefore, molecular imaging of CXCR4 bears a great potential for diagnostics and selecting patients for CXCR4-directed therapies. The CXCR4-directed positron emission tomography (PET) tracer [ 68 Ga]Pentixafor has been shown to visualize CXCR4 expression in various malignancies in vivo. Whereas this tracer has limitations compared to 18 F-Fluorodeoxyglucose ([ 18 F]FDG) in diagnostic PET imaging in peripheral tumour lesions, it might add valuable information in routine diagnostics and response assessment of tumours in close proximity to the central nervous system (CNS) and malignancies within this organ. As a proof-of-concept, we performed [ 68 Ga]Pentixafor PET imaging in a patient with extranodal marginal zone lymphoma (MZL) of the orbital cavities at diagnosis and for post-therapy response assessment. Compared to routinely conducted [ 18 F]FDG PET, the lymphoma lesions determined by magnetic resonance imaging (MRI) showed high tracer accumulation at diagnosis, which decreased upon treatment. We therefore propose that imaging of CXCR4 with [ 68 Ga]Pentixafor is a potential diagnostic tool for tumours close to or within the CNS and suggest this being studied in clinical trials.

  18. Radiation dose estimates for carbon-11-labelled PET tracers

    International Nuclear Information System (INIS)

    Aart, Jasper van der; Hallett, William A.; Rabiner, Eugenii A.; Passchier, Jan; Comley, Robert A.

    2012-01-01

    Introduction: Carbon-11-labelled positron emission tomography (PET) tracers commonly used in biomedical research expose subjects to ionising radiation. Dosimetry is the measurement of radiation dose, but also commonly refers to the estimation of health risk associated with ionising radiation. This review describes radiation dosimetry of carbon-11-labelled molecules in the context of current PET research and the most widely used regulatory guidelines. Methods: A MEDLINE literature search returned 42 articles; 32 of these were based on human PET data dealing with radiation dosimetry of carbon-11 molecules. Radiation burden expressed as effective dose and maximum absorbed organ dose was compared between tracers. Results: All but one of the carbon-11-labelled PET tracers have an effective dose under 9 μSv/MBq, with a mean of 5.9 μSv/MBq. Data show that serial PET scans in a single subject are feasible for the majority of radiotracers. Conclusion: Although differing in approach, the two most widely used regulatory frameworks (those in the USA and the EU) do not differ substantially with regard to the maximum allowable injected activity per PET study. The predictive validity of animal dosimetry models is critically discussed in relation to human dosimetry. Finally, empirical PET data are related to human dose estimates based on homogenous distribution, generic models and maximum cumulated activities. Despite the contribution of these models to general risk estimation, human dosimetry studies are recommended where continued use of a new PET tracer is foreseen.

  19. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  20. Using rare earth element tracers and neutron activation analysis to study rill erosion process

    International Nuclear Information System (INIS)

    Li Mian; Li Zhanbin; Ding Wengfeng; Liu Puling; Yao Wenyi

    2006-01-01

    Spatially averaged soil erosion data provide little information on the process of rill erosion. The dynamically varied data on the temporal and spatial distributions in the rill erosion process are needed to better understand the erosion process and reveal its innate characteristics. The objectives of this study were to examine the feasibility and effectiveness of rare earth element (REE) tracers and the neutron activation analysis (NAA) method on the study of the rill erosion process and to reveal quantitatively the relationships and characteristics of temporal and spatial distributions of sediment yield in rill erosion. Four REEs were used to study the changeable process of rill erosion at 4 slope positions. Four water inflow rates were applied to a 0.3x5 m soil bed at 3 slopes of 10.5%, 15.8% and 21.2% in scouring experiments. All of the runoff was collected in the experiment. Each sample was air-dried and well mixed. Then 20 g of each sample was sieved through 100-mesh and about a 50 mg sample was weighed for analysis of the four elemental compositions by NAA. Results indicate that the REE tracers and NAA method can be used to not only quantitatively determine soil erosion amounts on different slope segments, but also to reveal the changeable process of rill erosion amount. All of the relative errors of the experimental results were less than 25%, which is considered satisfactory on the study of rill erosion process

  1. Using rare earth element tracers and neutron activation analysis to study rill erosion process

    Energy Technology Data Exchange (ETDEWEB)

    Li Mian [Yellow River Institute of Hydraulic Research, Yellow River Conservancy Commission, Key Laboratory of Yellow River Sediment Research of Ministry of Water Resources, Shunhelu 45, Zhengzhou, Henan 450003 (China)]. E-mail: hnli-mian@163.com; Li Zhanbin [Xi' an University of Technology, Xi' an, Shaanxi 710048 (China); Institute of Soil and Water Conservation, Chinese Academy of Sciences and Ministry of Water Resources, Yangling, Shaanxi 712100 (China); Ding Wengfeng [Institute of Soil and Water Conservation, Yangtse River' s Scientific Research Institute, Wuhan, Hubei 430010 (China); Liu Puling [Institute of Soil and Water Conservation, Chinese Academy of Sciences and Ministry of Water Resources, Yangling, Shaanxi 712100 (China); Yao Wenyi [Yellow River Institute of Hydraulic Research, Yellow River Conservancy Commission, Key Laboratory of Yellow River Sediment Research of Ministry of Water Resources, Shunhelu 45, Zhengzhou, Henan 450003 (China)

    2006-03-15

    Spatially averaged soil erosion data provide little information on the process of rill erosion. The dynamically varied data on the temporal and spatial distributions in the rill erosion process are needed to better understand the erosion process and reveal its innate characteristics. The objectives of this study were to examine the feasibility and effectiveness of rare earth element (REE) tracers and the neutron activation analysis (NAA) method on the study of the rill erosion process and to reveal quantitatively the relationships and characteristics of temporal and spatial distributions of sediment yield in rill erosion. Four REEs were used to study the changeable process of rill erosion at 4 slope positions. Four water inflow rates were applied to a 0.3x5 m soil bed at 3 slopes of 10.5%, 15.8% and 21.2% in scouring experiments. All of the runoff was collected in the experiment. Each sample was air-dried and well mixed. Then 20 g of each sample was sieved through 100-mesh and about a 50 mg sample was weighed for analysis of the four elemental compositions by NAA. Results indicate that the REE tracers and NAA method can be used to not only quantitatively determine soil erosion amounts on different slope segments, but also to reveal the changeable process of rill erosion amount. All of the relative errors of the experimental results were less than 25%, which is considered satisfactory on the study of rill erosion process.

  2. The Shoreline Environment Atmospheric Dispersion Experiment (SEADEX): Meteorological and gas tracer data

    International Nuclear Information System (INIS)

    Johnson, W.B.; Cantrell, B.K.; Morley, B.M.; Uthe, E.E.; Nitz, K.C.

    1987-10-01

    The SEADEX atmospheric dispersion field study was conducted during the period May 28 to June 8, 1982, in northeastern Wisconsin, the vicinity of the Kewaunee Power Plant on the western shore of Lake Michigan. The specific objectives of SEADEX were to characterize (1) the atmospheric dispersion and (2) the meteorological conditions influencing this dispersion as completely as possible during the test period. This field study included a series of controlled tracer tests utilizing state-of-the-art tracer measurement technology to determine horizontal and vertical dispersion over both land and water. Extensive meteorological measurements were obtained to thoroughly characterize the three-dimensional structure of the atmospheric boundary controlling the dispersion process. This volume presents the meteorological and gas tracer data collected during the field study. 391 figs., 32 tabs

  3. Studies of MRI relaxivities of gadolinium-labeled dendrons

    Science.gov (United States)

    Pan, Hongmu; Daniel, Marie-Christine

    2011-05-01

    In cancer detection, imaging techniques have a great importance in early diagnosis. The more sensitive the imaging technique and the earlier the tumor can be detected. Contrast agents have the capability to increase the sensitivity in imaging techniques such as magnetic resonance imaging (MRI). Until now, gadolinium-based contrast agents are mainly used for MRI, and show good enhancement. But improvement is needed for detection of smaller tumors at the earliest stage possible. The dendrons complexed with Gd(DOTA) were synthesized and evaluated as a new MRI contrast agent. The longitudinal and transverse relaxation effects were tested and compared with commercial drug Magnevist, Gd(DTPA).

  4. Suitability of tracers; Eignung von Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, D. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany). Inst. fuer Hydrologie

    1999-02-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other. [Deutsch] Mit Hilfe der hydrologischen Markierungstechniken koennen Aussagen ueber die Richtung und die Geschwindigkeit von Bewegungen des unterirdischen Wassers gemacht werden. Der einfachere Fall liegt vor, wenn festgestellt werden soll, ob zwischen zwei Punkten eine hydrologische Verbindung besteht. Bei dieser Fliessrichtungsbestimmung sind die Forderungen an die Eigenschaften der einzusetzenden Tracer geringer als bei der Bestimmung der Geschwindigkeit des unterirdischen Wassers. Von den Geschwindigkeiten des unterirdischen Wassers ist die Abstands-(Fliess)geschwindigkeit, die definiert ist durch das Verhaeltnis aus dem Abstand und der wahren Fliesszeit zwischen zwei in Bewegungsrichtung gelegenen Punkten, durch Tracermethoden zu bestimmen. (orig.)

  5. Pipeline leak detection using volatile tracers

    International Nuclear Information System (INIS)

    Thompson, G.M.; Golding, R.D.

    1993-01-01

    A method of leak detection for underground storage tanks and pipelines adds volatile tracers to the products in the tanks and analyzes the surrounding shallow soil gases for tracer vapors. This method has several advantages: the success of the test is not limited by the size and structural design of the vessels, tanks can be tested at any fill level without taking the tank out of service, the location of a leak along a pipeline is clearly marked by the location of the tracer, and liquid leaks as small as 0.2 liters per hour (lph) can be detected. A limitation is: the backfill material must have some degree of air permeability in the zone above the water table. Several field tests document the success achieved using this method. A tracer leak detection system was installed at Homestead AFB after several other testing methods failed to locate a leak at a valve pit location along approximately 4 kilometers of fuel transfer piping. The leak was detected to the side of the valve pit at a depth of approximately 2.5 meters below the ground surface. Another installation of Edwards AFB involved the collection of 415 soil gas samples along approximately 3,050 meters of 15.25-centimeter fiberglass pipeline. Fourteen separate leaks were detected

  6. Using predictive uncertainty analysis to optimise tracer test design and data acquisition

    Science.gov (United States)

    Wallis, Ilka; Moore, Catherine; Post, Vincent; Wolf, Leif; Martens, Evelien; Prommer, Henning

    2014-07-01

    Tracer injection tests are regularly-used tools to identify and characterise flow and transport mechanisms in aquifers. Examples of practical applications are manifold and include, among others, managed aquifer recharge schemes, aquifer thermal energy storage systems and, increasingly important, the disposal of produced water from oil and shale gas wells. The hydrogeological and geochemical data collected during the injection tests are often employed to assess the potential impacts of injection on receptors such as drinking water wells and regularly serve as a basis for the development of conceptual and numerical models that underpin the prediction of potential impacts. As all field tracer injection tests impose substantial logistical and financial efforts, it is crucial to develop a solid a-priori understanding of the value of the various monitoring data to select monitoring strategies which provide the greatest return on investment. In this study, we demonstrate the ability of linear predictive uncertainty analysis (i.e. “data worth analysis”) to quantify the usefulness of different tracer types (bromide, temperature, methane and chloride as examples) and head measurements in the context of a field-scale aquifer injection trial of coal seam gas (CSG) co-produced water. Data worth was evaluated in terms of tracer type, in terms of tracer test design (e.g., injection rate, duration of test and the applied measurement frequency) and monitoring disposition to increase the reliability of injection impact assessments. This was followed by an uncertainty targeted Pareto analysis, which allowed the interdependencies of cost and predictive reliability for alternative monitoring campaigns to be compared directly. For the evaluated injection test, the data worth analysis assessed bromide as superior to head data and all other tracers during early sampling times. However, with time, chloride became a more suitable tracer to constrain simulations of physical transport

  7. Tracing wastewater effluents in surface and groundwaters: a couple approach with organic/inorganic tracers and isotopes

    Science.gov (United States)

    Petelet-Giraud, Emmanuelle; Baran, Nicole; Soulier, Coralie

    2017-04-01

    In the context of land use change, the origins of contamination of water resources are often multiple, including for a single chemical element or molecule. For instance, excess of nitrates in both surface and groundwater can originate from agricultural practices and wastewater effluents. The discrimination of the origins and vectors of contamination in the environment is both an environmental and societal issue in order to define an integrated water resources management at the catchment or water body scale by implementing appropriate measures to effectively struggle against pollution. The objective of this study is to define a methodology for the identification of a "domestic wastewater" contamination within surface waters and groundwater. An ideal tracer should be conservative, persistent in the different water compartments, present in quantity above the detection limit and originate from a single type of pollution source. There is, however, no ideal tracer in the strict sense. Indeed, even chloride which is present in quantity in wastewater, and which behaves conservatively in the environment, is not an univocal tracer of wastewater, as it may come from atmospheric inputs, from the dissolution of evaporitic rocks, from the salting of roads or from fertilizers. To overcome this limitation, in this study, we propose a multi-tracer approach (chemical and isotopic) to identify and validate the relevance of foreseen tracers. Among the relevant tracers of wastewater, the following may be used for their intrinsic or combined discriminant power: 1) organic effluent tracers: nitrogen contents and isotopic ratios of nitrogen and oxygen of nitrates; 2) tracer of detergents: boron contents and boron isotopes; 3) pharmaceuticals tracers: e.g. carbamazepine, ibuprofen, paracetamol, gadolinium anomaly; 4) life-style tracers: e.g. caffeine. The originality of the study relies on small capacities wastewater treatment plants without tertiary treatment process. Results on a

  8. Application of fluorescent-and radioactive tracers in Sedimentalogy

    International Nuclear Information System (INIS)

    Alencar, L.M.L. de.

    1981-01-01

    The development of techniques of sediment labelling, creating the possibility of using fluorescent and radioactive tracers not yet applied in Brazil, in the area of sedimentology, is studied. (A.R.H.) [pt

  9. Determination of the self purification of streams using tracers

    International Nuclear Information System (INIS)

    Salviano, J.S.

    1982-04-01

    A methodology for the 'in situ' evaluation of the self purification of streams is discussed. It consists of the simultaneous injection of two tracers into the stream. One of the tracers is oxidized by biochemical processes. It can be either artificially supplied to the stream or a naturally present component can be used. This tracer is used for the determination of the self purification parameters. The other tracer is conservative and allows for the hydrodynamic effects. Tests have been carried out in two streams with quite different hydrodynamic and physicochemical conditions. In the first stream, with a flow-rate of about 0.9 m 3 /s, urea was used as the nonconservative tracer. In the other stream, which had a flow-rate of about 5 m 3 /s, only a radioactive tracer has been used, and the rate of biochemical oxidation has been determined from BOD measurements. Calculations have been implemented on a digital computer. In both cases it was found that the reoxygenation rate is more conveniently determined by empirical formulas. Results from both tests have been deemed realistic by comparison with similar experiments. (Author) [pt

  10. Health complaints among nurses working near MRI scanners-A descriptive pilot study

    International Nuclear Information System (INIS)

    Wilen, Jonna; Vocht, Frank de

    2011-01-01

    A questionnaire-based descriptive pilot study was conducted among all nurses routinely working with MRI in the Northern part of Sweden to provide an indication of the self-reported prevalence of health complaints related to working with MRI systems. Fifty-nine nurses (88% response rate), with on average 8 (±6) years experience with MRI scanning procedures, returned the questionnaire. In total, 9 nurses (15%) reported regularly experiencing at least one of the health complaints (1-5% for specific health complaints) attributed to arise or be aggravated by their presence in the MRI scanning room. Stratification of the results indicated that reporting of adverse symptoms was not related to the level of occupational workload/stress. However, reporting of health complaints was related to the strength of the magnet(s) the nurses worked with, with 57% of symptoms reported by those nurses working with the strongest systems (both 1.5 and 3 T scanners in this population). Although this descriptive study did not include a control population and was based on self-reporting of health complaints, these data indicate that the prevalence of reported health complaints is not related to perceived work load or occupational stress, but does confirm data from other occupational sectors and indicates that the prevalence of adverse health complaints increases with the strength of the MRI system for nurses as well.

  11. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    International Nuclear Information System (INIS)

    Duan, G; Zhao, X; Seren, H R; Chen, C; Zhang, X

    2015-01-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen. (paper)

  12. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    Energy Technology Data Exchange (ETDEWEB)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina [Geneva University Hospital, Department of Radiology and Medical Informatics, Geneva 14 (Switzerland); Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge [Geneva University Hospital, EEG and Epilepsy Unit, Department of Neurology, Geneva 14 (Switzerland); Heinzer, Susanne [Philips AG Healthcare, Zuerich (Switzerland); Iannotti, Giannina R. [Geneva University Hospital, Functional Brain Mapping Laboratory, Department of Fundamental Neurosciences, Geneva 14 (Switzerland)

    2015-04-17

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  13. All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI

    International Nuclear Information System (INIS)

    Grouiller, Frederic; Delattre, Benedicte M.A.; Lazeyras, Francois; Ratib, Osman; Vargas, Maria I.; Garibotto, Valentina; Pittau, Francesca; Spinelli, Laurent; Seeck, Margitta; Vulliemoz, Serge; Heinzer, Susanne; Iannotti, Giannina R.

    2015-01-01

    In patients with pharmacoresistant focal epilepsy, resection of the epileptic focus can lead to freedom from seizures or significant improvement in well-selected candidates. Localization of the epileptic focus with multimodal concordance is crucial for a good postoperative outcome. Beyond the detection of epileptogenic lesions on structural MRI and focal hypometabolism on FDG PET, EEG-based Electric Source Imaging (ESI) and simultaneous EEG and functional MRI (EEG-fMRI) are increasingly applied for mapping epileptic activity. We here report presurgical multimodal interictal imaging using a hybrid PET/MR scanner for single-session FDG PET, MRI, EEG-fMRI and ESI. This quadrimodal imaging procedure was performed in a single session in 12 patients using a high-density (256 electrodes) MR-compatible EEG system and a hybrid PET/MR scanner. EEG was used to exclude subclinical seizures during uptake of the PET tracer, to compute ESI on interictal epileptiform discharges and to guide fMRI analysis for mapping haemodynamic changes correlated with interictal epileptiform activity. The whole multimodal recording was performed in less than 2 hours with good patient comfort and data quality. Clinically contributory examinations with at least two modalities were obtained in nine patients and with all modalities in five patients. This single-session quadrimodal imaging procedure provided reliable and contributory interictal clinical data. This procedure avoids multiple scanning sessions and is associated with less radiation exposure than PET-CT. Moreover, it guarantees the same medication level and medical condition for all modalities. The procedure improves workflow and could reduce the duration and cost of presurgical epilepsy evaluations. (orig.)

  14. Collective and tracer diffusion kinetics in the ternary random alloy

    International Nuclear Information System (INIS)

    Belova, I.V.; Murch, G.E.; Allnatt, A.R.

    2002-01-01

    In this study, collective and tracer diffusion kinetics is addressed for the ternary random alloy. A formal solution from the self-consistent theory of Moleko et al (Moleko L K, Allnatt A R and Allnatt E L 1989 Phil. Mag. A 59 141) is derived for collective diffusion and compared with the corresponding solution for the binary random alloy. Tracer diffusion in the ternary alloy is treated from the perspective of a special case of the quaternary random alloy. Results from Monte Carlo calculations for tracer and collective correlation factors (for the bcc ternary random alloy) are found to be in excellent agreement with this self-consistent theory but in only semi-quantitative agreement with the earlier theory of Manning (Manning J R 1971 Phys. Rev. B 4 1111). (author)

  15. Leak detection and localization in natural and artificial dams using tracer techniques

    International Nuclear Information System (INIS)

    Molinari, J.

    1975-01-01

    Leak detection and localization procedures using often-unknown techniques of identification by natural or artificial tracers are reported. From the analysis of data supplied by natural tracers, or by artificial tracer methods which involve the direct observation of warning phenomena, it is possible to estimate the extent of the infiltrations, define their origin and under certain circumstances determine the main hydrodynamic flow parameters so that their development may be followed. The examples of application and interpretation were taken from the numerous studies carried out in this field by the CEA, where many original investigation methods have been employed [fr

  16. National Biomedical Tracer Facility. Project definition study

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, R.

    1995-02-14

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research: fast neutrons, thermal neutrons, and particle beams (H{sup -}, H{sup +}, and D{sup +}). The proposed NBTF facility includes an 80 MeV, 1 mA H{sup -} cyclotron that will produce proton-induced (neutron deficient) research isotopes.

  17. Application of tracer techniques to the study of trematode infections: Pathological and epidemiological aspects

    International Nuclear Information System (INIS)

    Nansen, P.

    1976-01-01

    Liver fluke and blood fluke infections cause heavy losses in animal production. The infections are characterized by a concomitant anaemia and dysproteinaemia. A review is made of radioisotopic tracer studies which have contributed to an understanding of the dynamic processes underlying the blood changes. Such studies have provided important information about the activity of the parasites, for example, how they cause disease and how they influence animal production. Radioisotopic techniques have also been utilized in the study of free-living fluke larvae. A brief outline of principles and fields if investigations within this area is given. (author)

  18. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI

    Science.gov (United States)

    Chun, Se Young; Reese, Timothy G.; Ouyang, Jinsong; Guerin, Bastien; Catana, Ciprian; Zhu, Xuping; Alpert, Nathaniel M.; El Fakhri, Georges

    2014-01-01

    Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. Methods Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. Results Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5–8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%–276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%–92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. Conclusion Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection

  19. Influence of nutrition on protein synthesis and 15N tracer data in man

    International Nuclear Information System (INIS)

    Faust, H.

    1984-01-01

    Quantitative studies and measurements of parameters of the protein metabolism in vivo require the isotope methodology. Different 15 N tracer methods with special modifications are available which can be used depending on clinical problems. The oral single pulse application of [ 15 N]glycine is equal to other isotope tracer techniques provided that the basic assumptions of the application are fullfilled. The protein metabolism is clearly influenced by the nutritional status whereby the protein synthesis is more sensitive than the breakdown to altered dietary intakes of protein and energy. The importance of standardized experimental conditions is emphasized for studies with 15 N and the interpretation of tracer data. (author)

  20. Natural tracer profiles across argillaceous formations

    International Nuclear Information System (INIS)

    Mazurek, Martin; Alt-Epping, Peter; Bath, Adrian; Gimmi, Thomas; Niklaus Waber, H.; Buschaert, Stephane; Canniere, Pierre De; Craen, Mieke De; Gautschi, Andreas; Savoye, Sebastien; Vinsot, Agnes; Wemaere, Isabelle; Wouters, Laurent

    2011-01-01

    Highlights: → Solute transport processes in clay and shale formations at nine sites are examined. → Conservative pore-water tracers (e.g. Cl - , δ 18 O, δ 2 H, He) show regular profiles. → These indicate the dominance of diffusive transport over times of 10 5 -10 6 years. → The contribution of vertical advection to transport is limited or negligible. → Modelled evolution times are in line with independent palaeo-hydrogeological data. - Abstract: Argillaceous formations generally act as aquitards because of their low hydraulic conductivities. This property, together with the large retention capacity of clays for cationic contaminants, has brought argillaceous formations into focus as potential host rocks for the geological disposal of radioactive and other waste. In several countries, programmes are under way to characterise the detailed transport properties of such formations at depth. In this context, the interpretation of profiles of natural tracers in pore waters across the formations can give valuable information about the large-scale and long-term transport behaviour of these formations. Here, tracer-profile data, obtained by various methods of pore-water extraction for nine sites in central Europe, are compiled. Data at each site comprise some or all of the conservative tracers: anions (Cl - , Br - ), water isotopes (δ 18 O, δ 2 H) and noble gases (mainly He). Based on a careful evaluation of the palaeo-hydrogeological evolution at each site, model scenarios are derived for initial and boundary pore-water compositions and an attempt is made to numerically reproduce the observed tracer distributions in a consistent way for all tracers and sites, using transport parameters derived from laboratory or in situ tests. The comprehensive results from this project have been reported in . Here the results for three sites are presented in detail, but the conclusions are based on model interpretations of the entire data set. In essentially all cases, the

  1. Comparative study on developmental stages of the clavicle by postmortem MRI and CT imaging

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels; Jensen, K.E.

    2013-01-01

    Objectives: The developmental stages of the clavicles are important for forensic age estimation purposes in adolescents. This study compares the 4-stage system to evaluate the ossification of the medial end of the clavicle as visualized by magnetic resonance imaging (MRI) and computed tomography...... (CT). As several forensic institutes routinely perform CT scans, the large amount of available data may serve as reference sample for MRI in specific cases. Material and methods: This prospective study included an MRI and CT scan of 47 autopsy cases performed prior to medico-legal autopsy (age range...

  2. Adherence to MRI protocol consensus guidelines in multiple sclerosis: an Australian multi-centre study

    International Nuclear Information System (INIS)

    Curley, Michael; Josey, Lawrence; Lucas, Robyn; Dear, Keith; Taylor, Bruce V.; Coulthard, Alan; Ausimmune Investigator Group

    2012-01-01

    Multiple sclerosis (MS) is a debilitating disease that causes significant morbidity within a young demographic. Diagnostic guidelines for MS have evolved, and imaging has played an increasingly important role in diagnosis over the last two decades. For imaging to contribute to diagnosis in a meaningful way, it must be reproducible. Consensus guidelines for MRI in MS exist to define correct sequence type and imaging technique, but it is not clear to what extent they are followed. This study reviewed MRI studies performed on Australian individuals presenting with a first clinical diagnosis of central nervous system demyelination (FCD) for adherence to published guidelines and discussed practical implementation of MS guidelines in light of recent updates. The Ausimmune study was a prospective case control study of Australian participants presenting with FCD from 2003 to 2006. Baseline cranial and spinal cord MRI studies of 226 case participants from four separate Australian regions were reviewed. MRI sequences were classified according to anatomical location, slice plane, tissue weighting and use of gadolinium-containing contrast media. Results were compared with the 2003 Consortium of Multiple Sclerosis Centres MRI protocol for the diagnosis of MS. The composition of core cranial MRI sequences performed varied across the 226 scans. Of the studies, 91% included sagittal fluid attenuated inversion recovery (FLAIR) sequences. Cranial axial T2-weighted, axial FLAIR and axial proton density-weighted sequences were performed in 88%, 60% and 16% (respectively) of scans. Only 25% of the studies included a T1-weighted contrast-enhanced sequence. Concordance with the guidelines in all sequences was very low (2). Only a small number of MRI investigations performed included all of the sequences stipulated by consensus guidelines. This is likely due to poor awareness in the imaging community of the guidelines and the rationale behind certain sequences. Radiologists with a sub

  3. Motor function deficits in schizophrenia: an fMRI and VBM study

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sadhana; Modi, Shilpi; Kumar, Pawan; Singh, Namita; Khushu, Subash [Institute of Nuclear Medicine and Allied Sciences (INMAS), NMR Research Center, Delhi (India); Goyal, Satnam; Bhatia, Triptish; Deshpande, Smita N. [RML Hospital, PGIMER, New Delhi (India)

    2014-05-15

    To investigate whether the motor functional alterations in schizophrenia (SZ) are also associated with structural changes in the related brain areas using functional magnetic resonance imaging (fMRI) and voxel-based morphometry (VBM). A sample of 14 right-handed SZ patients and 14 right-handed healthy control subjects matched for age, sex, and education were examined with structural high-resolution T1-weighted MRI; fMRI images were obtained during right index finger-tapping task in the same session. fMRI results showed reduced functional activation in the motor areas (contralateral precentral and postcentral gyrus) and ipsilateral cerebellum in SZ subjects as compared to healthy controls (n = 14). VBM analysis also revealed reduced grey matter in motor areas and white matter reduction in cerebellum of SZ subjects as compared to controls. The present study provides an evidence for a possible association between structural alterations in the motor cortex and disturbed functional activation in the motor areas in persons affected with SZ during a simple finger-tapping task. (orig.)

  4. Motor function deficits in schizophrenia: an fMRI and VBM study

    International Nuclear Information System (INIS)

    Singh, Sadhana; Modi, Shilpi; Kumar, Pawan; Singh, Namita; Khushu, Subash; Goyal, Satnam; Bhatia, Triptish; Deshpande, Smita N.

    2014-01-01

    To investigate whether the motor functional alterations in schizophrenia (SZ) are also associated with structural changes in the related brain areas using functional magnetic resonance imaging (fMRI) and voxel-based morphometry (VBM). A sample of 14 right-handed SZ patients and 14 right-handed healthy control subjects matched for age, sex, and education were examined with structural high-resolution T1-weighted MRI; fMRI images were obtained during right index finger-tapping task in the same session. fMRI results showed reduced functional activation in the motor areas (contralateral precentral and postcentral gyrus) and ipsilateral cerebellum in SZ subjects as compared to healthy controls (n = 14). VBM analysis also revealed reduced grey matter in motor areas and white matter reduction in cerebellum of SZ subjects as compared to controls. The present study provides an evidence for a possible association between structural alterations in the motor cortex and disturbed functional activation in the motor areas in persons affected with SZ during a simple finger-tapping task. (orig.)

  5. Functional MRI in pre-surgical planning: Case study and cautionary notes

    Directory of Open Access Journals (Sweden)

    Bruce S Spottiswoode

    2012-09-01

    Full Text Available Background. Since its inception almost 20 years ago, functional magnetic resonance imaging (fMRI has greatly advanced our knowledge of human brain function. Although the clinical applications of fMRI are still limited, there have recently been encouraging advances for its use in pre-operative functional cortical mapping to identify potentially eloquent areas prior to neurosurgery. Objectives. We explore the potential use of this emerging technique by presenting a neurosurgical case study, as performed at the Cape Universities Brain Imaging Centre (CUBIC, Tygerberg, Cape Town. We conclude with a brief summary of the potential pitfalls of this technique, as well as cautionary guidelines based on our experience. Methods and results. A 22-year-old male patient from Tygerberg Hospital underwent the successful resection of an anaplastic astrocytoma after fMRI presurgical planning at our facility. The subject was able to leave the ward unassisted. Conclusion. If consideration is given to the many limitations of this emerging technique, fMRI can be useful in aiding the neurosurgeon in pre-operative planning of his surgical approach.

  6. Methods of 15N tracer research in biological systems

    International Nuclear Information System (INIS)

    Hirschberg, K.; Faust, H.

    1985-01-01

    The application of the stable isotope 15 N is of increasing importance in different scientific disciplines, especially in medicine, agriculture, and the biosciences. The close correlation between the growing interest and improvements of analytical procedures resulted in remarkable advances in the 15 N tracer technique. On the basis of the latest results of 15 N tracer research in life sciences and agriculture methods of 15 N tracer research in biological systems are compiled. The 15 N methodology is considered under three headings: Chemical analysis with a description of methods of sample preparation (including different separation and isolation methods for N-containing substances of biological and agricultural origin) and special procedures converting ammonia to molecular nitrogen. Isotopic analysis with a review on the most important methods of isotopic analysis of nitrogen: mass spectrometry (including the GC-MS technique), emission spectrometry, NMR spectroscopy, and other analytical procedures. 15 N-tracer techniques with a consideration of the role of the isotope dilution analysis as well as different labelling techniques and the mathematical interpretation of tracer data (modelling, N turnover experiments). In these chapters also sources of errors in chemical and isotopic analysis, the accuracy of the different methods and its importance on tracer experiments are discussed. Procedures for micro scale 15 N analysis and aspects of 15 N analysis on the level of natural abundance are considered. Furthermore some remarks on isotope effects in 15 N tracer experiments are made. (author)

  7. Study of cysticercosis in the fourth ventricle by CSF cinema MRI

    International Nuclear Information System (INIS)

    Wang Lianqing; Liu Lianxiang; Wu Jie; Wu Jing; Zhang Renshu; Wu Yujin

    1997-01-01

    Purpose: To evaluate the diagnostic value of cysticercosis in the fourth ventricle by CSF cinema MRI. Materials and methods: Nine patients with intraventricular cysticercosis in the fourth ventricle were studied. The diagnosis was confirmed by surgery in all cases. All of these patients were examined systematically before the operation and studied with CSF cinema MRI in mid sagittal section and finger-gated scan technique. Results: (1) The path of CSF flow was directly displayed. All cysticercosis presented as a filling defect, and a cyst with a smooth wall. (2) The ventricular compliance was normal in cysticercosis. (3) The cysticercosis in active stage was free in the fourth ventricle and could be rolled over, its shape might change slightly within a cardiac cycle. In the degenerative stage, its wall could adhere to the ependyma and obstruct the CSF flow. Conclusion: CSF cinema MRI can demonstrate the degree of obstruction and pattern of CSF flow in cysticercosis of the fourth ventricle, thereby providing useful information for proper management

  8. Serial MRI and MRS studies with unusual findings in Rasmussen's encephalitis

    International Nuclear Information System (INIS)

    Tuerkdogan-Soezueer, D.; Oezek, M.M.; Pamir, M.N.; Sav, A.; Dincer, A.

    2000-01-01

    Rasmussen's syndrome is characterized by intractable seizures and progressive neuropsychiatric deterioration secondary to unilateral cortical inflammation and tissue destruction. Diagnosis of Rasmussen's syndrome in the early phase depends mainly on the clinical features. Neuroimaging and histopathologic examinations may not be specific during this period. We report a case of Rasmussen's syndrome followed by serial MRI and magnetic resonance spectroscopy (MRS) studies over a 3- to 16-month period. A healthy 6-year-old boy presented with focal motor seizures. An MRI study demonstrated prominent enlargement and T2 hyperintensity of the left mesial temporal lobe and perisylvian region. This early finding evolved to volume loss and later progressive atrophy of the ipsilateral hemisphere when epilepsia partialis continua occurred. Being aware of those early MRI features in a patient with increasing frequency of focal motor seizures should suggest Rasmussen's syndrome. In addition, we found prominently increased myoinositol concentration in atrophic cortex which might reflect increased gliosis in the late period of the disease. (orig.)

  9. Slowly progressive fluent aphasia; Clinical features and an imaging study including MRI, SPECT and PET

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Yasuhisa; Momose, Toshimitsu; Watanabe, Toshiaki; Ishikawa, Takashi; Iwata, Makoto (Tokyo Univ. (Japan). Faculty of Medicine); Bando, Mitsuaki

    1991-05-01

    Three patients with slowly progressive fluent aphasia are reported. One of the patients presented with memory disturbance. They were characterized clinically by having selective deficits in vocabulary, which resulted in impairment of confrontation naming, and auditory comprehension. MRI showed an atrophy not only in the left temporal lobe (including the superior, middle and inferior temporal gyri), hippocampus, parahippocampual gyrus, and fusiform gyrus, but also in the left parietal lobe. I-123 IMP SPECT and F-18 FDG PET were used to determine regional cerebral blood flow and regional cerebral metabolic rate, respectively. In addition to the decreased tracer uptake in the left temporal and/or parietal lobe, a decreased uptake was seen in the bilateral basal ganglia, the inner side of the temporal lobe (including the bilateral hippocampus), the right anterior temporal lobe, and the left thalamus. These findings may deny the previous thought that lesions are localized in slowly progressive fluent aphasia. Furthermore, noticeable difficulty in naming, i.e., patients unable to recognize the right answer, are considered attributable to widespread lesions from the whole left temporal lobe, including the hippocampus, to the right temporal lobe. (N.K.).

  10. Seepage studies through hydraulic structures and their foundations by inactive and radio tracers

    International Nuclear Information System (INIS)

    Ansari, Azher; Mahajan, N.M.; Kamble, M.D.

    1977-01-01

    In the last ten years extensive efforts have been made by the Central Water and Power Research Station, Pune to study seepage by means of inactive and radiotracers. Various inactive tracers like electrolytes and organic dyes and radiotracers like 82 Br and 3 H in the form of tritiated water have been used for location of source of seepage. Different techniques like borehole dilution, in situ detection at various observation points and analysis of water samples in liquid scintillation spectrometer in the laboratory have been employed to suit the field conditions. Some typical studies at river valley projects indicating the techniques are enumerated. (author)

  11. Hearing loss associated with repeated MRI acquisition procedure-related acoustic noise exposure: an occupational cohort study.

    Science.gov (United States)

    Bongers, Suzan; Slottje, Pauline; Kromhout, Hans

    2017-11-01

    To study the effects of repeated exposure to MRI-related acoustic noise during image acquisition procedures (scans) on hearing. A retrospective occupational cohort study was performed among workers of an MRI manufacturing facility (n=474). Longitudinal audiometry data from the facility's medical surveillance scheme collected from 1973 to 2010 were analysed by studying the association of cumulative exposure to MRI-related acoustic noise from voluntary (multiple) MRI scans and the hearing threshold of the volunteer. Repeated acoustic noise exposure during volunteer MRI scans was found to be associated with a small exposure-dependent increased rate change of hearing threshold level (dB/year), but the association was only found related to the number of voluntary MRI scans and not to modelled cumulative noise exposure (dB*hour) based on MRI-system type. The increased rate change of hearing threshold level was found to be statistically significant for the frequencies 500, 1000, 2000, 3000 and 4000 Hz in the right ear. From our longitudinal cohort study, it appeared that exposure to noise from voluntarily MRI scans may have resulted in a slight amount of hearing loss. Mandatory use of hearing protection might have prevented more severe hearing loss. Lack of consistency in findings between the left and right ears and between the two exposure measures prohibits definitive conclusions. Further research that addresses the study's methodological limitations is warranted to corroborate our findings. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Using REE tracers to measure sheet erosion changing to rill erosion

    International Nuclear Information System (INIS)

    Liu Puling; Xue Yazhou; Song Wei; Wang Mingyi; Ju Tongjun

    2004-01-01

    Rare Earth Elements (REE) tracer method was used to study sheet erosion changing to rill erosion on slope land. By placing different rare earth elements of different soil depth across a slope in an indoor plot, two simulated rainfalls were applied to study the change of erosion type and the rill erosion process. The results indicate that the main erosion type is sheet erosion at the beginning of the rainfalls, and serious erosion happens after rill erosion appears. Accumulated sheet and rill erosion amounts increase with the rainfalls time. The percentage of sheet erosion amount decreases and rill erosion percentage increases with time. At the end of the rainfalls, the total rill erosion amounts are 4-5 times more than sheet erosion. In this paper, a new REE tracer method was used to quantitatively distinguish sheet and rill erosion amounts. The new REE tracer method should be useful to future studying of erosion processes on slope lands. (authors)

  13. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    Energy Technology Data Exchange (ETDEWEB)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios [NYU Langone Medical Center, Department of Radiology, Musculoskeletal Division, New York, NY (United States); Benedick, Alex [Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Obuchowski, Nancy A. [Cleveland Clinic, Department of Quantitative Health Sciences, Cleveland, OH (United States); Polster, Joshua M.; Schils, Jean; Subhas, Naveen [Cleveland Clinic, Department of Radiology, Musculoskeletal Division, Cleveland, OH (United States); Chang, I. Yuan Joseph [Texas Scottish Rite Hospital for Children, Dallas, TX (United States)

    2018-01-15

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  14. Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol. A multi-institutional multi-reader study

    International Nuclear Information System (INIS)

    FitzGerald Alaia, Erin; Beltran, Luis S.; Garwood, Elisabeth; Burke, Christopher J.; Gyftopoulos, Soterios; Benedick, Alex; Obuchowski, Nancy A.; Polster, Joshua M.; Schils, Jean; Subhas, Naveen; Chang, I. Yuan Joseph

    2018-01-01

    To compare diagnostic performance of a 5-min knee MRI protocol to that of a standard knee MRI. One hundred 3 T (100 patients, mean 38.8 years) and 50 1.5 T (46 patients, mean 46.4 years) MRIs, consisting of 5 fast, 2D multi-planar fast-spin-echo (FSE) sequences and five standard multiplanar FSE sequences, from two academic centers (1/2015-1/2016), were retrospectively reviewed by four musculoskeletal radiologists. Agreement between fast and standard (interprotocol agreement) and between standard (intraprotocol agreement) readings for meniscal, ligamentous, chondral, and bone pathology was compared for interchangeability. Frequency of major findings, sensitivity, and specificity was also tested for each protocol. Interprotocol agreement using fast MRI was similar to intraprotocol agreement with standard MRI (83.0-99.5%), with no excess disagreement (≤ 1.2; 95% CI, -4.2 to 3.8%), across all structures. Frequency of major findings (1.1-22.4% across structures) on fast and standard MRI was not significantly different (p ≥ 0.215), except more ACL tears on fast MRI (p = 0.021) and more cartilage defects on standard MRI (p < 0.001). Sensitivities (59-100%) and specificities (73-99%) of fast and standard MRI were not significantly different for meniscal and ligament tears (95% CI for difference, -0.08-0.08). For cartilage defects, fast MRI was slightly less sensitive (95% CI for difference, -0.125 to -0.01) but slightly more specific (95% CI for difference, 0.01-0.5) than standard MRI. A fast 5-min MRI protocol is interchangeable with and has similar accuracy to a standard knee MRI for evaluating internal derangement of the knee. (orig.)

  15. MRI in patients with portal hypertension (preoperative and postoperative studies). The first 15 cases

    Energy Technology Data Exchange (ETDEWEB)

    Pozzato, A; Cattoni, F; Baldini, U and others

    1987-01-01

    Fifteen patients with portal hypertension were examined by magnetic resonance imaging (MRI) using spin-echo sequences. Sagittal and transaxial images were obtained in all cases. Ten subjects have been evaluated after portosystemic shunt operations (6 portocaval and 4 splenorenal shunts); 5 patients were studied by MRI before shunt placements. Angiographic correlation was obtained in 15 cases. In each of the preoperative examinations, MRI accurately depicted inferior vena cava, portal vein and splenic vein. Shunt patency was documented in 10/10 postoperative studies: portacaval shunts patency was better determined in the transaxial plane while splenorenal shunts were better demonstrted in the sagittal plane. Thus, MRI seems to be an accurate and noninvasive method for detecting portosystemic shunt patency without the use of intravenous contrast media and without patient exposure to radiation.

  16. MRI assessment program

    International Nuclear Information System (INIS)

    1988-05-01

    Usage, cost and efficacy data from the MRI Assessment Program to 30 March 1988 is presented, as a continuation of an earlier analysis. Analysis has been performed on data from 8565 examinations relating to 7997 patients at 4 hospitals. MRI was used mainly for examination of the head and spine. Some details of the follow up studies being conducted on selected patients and disease categories are given. A consensus statement is included which summaries the view of the Technical Committee on the potential applications of MRI in Australia. The MRI unit quench incident at Royal Adelaide Hospital is described. Refs., 10 figs., tabs

  17. Optimizing imaging in suspected appendicitis (OPTIMAP-study: A multicenter diagnostic accuracy study of MRI in patients with suspected acute appendicitis. Study Protocol

    Directory of Open Access Journals (Sweden)

    Bossuyt Patrick MM

    2010-10-01

    Full Text Available Abstract Background In patients with clinically suspected appendicitis, imaging is needed to substantiate the clinical diagnosis. Imaging accuracy of ultrasonography (US is suboptimal, while the most accurate technique (CT is associated with cancer related deaths through exposure to ionizing radiation. MRI is a potential replacement, without associated ionizing radiation and no need for contrast medium administration. If MRI is proven to be sufficiently accurate, it could be introduced in the diagnostic pathway of patients with suspected appendicitis, increasing diagnostic accuracy and improving clinical outcomes, without the risk of radiation induced cancer or iodinated contrast medium-related drawbacks. The multicenter OPTIMAP study was designed to estimate the diagnostic accuracy of MRI in patients with suspected acute appendicitis in the general population. Methods/Design Eligible for this study are consecutive patients presenting with clinically suspected appendicitis at the emergency department in six centers. All patients will undergo imaging according to the Dutch guideline for acute appendicitis: initial ultrasonography in all and subsequent CT whenever US does not confirm acute appendicitis. Then MRI is performed in all patients, but the results are not used for patient management. A final diagnosis assigned by an expert panel, based on all available information including 3-months follow-up, except MRI findings, is used as the reference standard in estimating accuracy. We will calculate the sensitivity, specificity, predictive values and inter-observer agreement of MRI, and aim to include 230 patients. Patient acceptance and total imaging costs will also be evaluated. Discussion If MRI is found to be sufficiently accurate, it could replace CT in some or all patients. This will limit or obviate the ionizing radiation exposure associated risk of cancer induction and contrast medium induced nephropathy with CT, preventing the burden and

  18. The use of yield tracers for the determination of aplha-emitting actinides in the marine environment

    International Nuclear Information System (INIS)

    Harvey, B.R.; Lovett, M.B.

    1984-01-01

    The need for yield tracers and their general analytical application is briefly discussed and more fully expanded in the context of the radiochemical determination of alpha-emitting actinides. The important alpha-emitting nuclides of the actinide elements found in the marine environment are listed. The environmental significance and analytical implications arising from the multiplicity of valency states found amongst the earlier members of the actinide series are noted. The tracers that are available for analyses and their selection and suitability for particular applications are discussed and the general precautions that need to be observed in their use are given. Use of the dual tracer technique in the study of speciation of the actinides in the marine environment is discussed with special reference to plutonium in sea water. The limited applicability of plutonium as a yield tracer in the study of neptunium speciation is noted and the latest developments in the investigation of 235 Np as an alternative tracer for neptunium are given. The possibility of the joint use of americium and curium nuclides as tracers in the study of the speciation of these two elements is explored. (orig.)

  19. Holdup time measurement by radioactive tracers in pulp production

    International Nuclear Information System (INIS)

    Roetzer, H.; Donhoffer, D.

    1988-12-01

    A batch of pulp was to be labelled before passing two bleaching towers of a pulp plant. Activated glass fibres were used as a tracer, which contained 24-Na with a half-life of 15 hours. It was shown in laboratory tests, that the glass fibres were suitable for transport studies of wood pulp. For use in the tests the fibres were activated and suspended in water. Due to the small diameter of the fibres (2-5 micrometers) this suspension shows physical properties very similar to the pulp. For detection six scintillation probes were mounted at different positions outside the bleaching tower. Radiation protection during the test was very easy due to the low total activity of the tracer material. Residence time distributions for both towers were measured. The successful tracer experiments show, that the method of labelling is suited for investigations of material transport in the pulp and paper industry. 3 figs., 11 refs., 2 tabs. (Author)

  20. Tracers Detect Aquifer Contamination

    National Research Council Canada - National Science Library

    Enfield, Carl

    1995-01-01

    The EPA's National Laboratory (NRMRL) at Ada, OK, along with the University of Florida and the University of Texas, have developed a tracer procedure to detect the amount of contamination in aquifer formations...

  1. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.

    Science.gov (United States)

    Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul

    2018-02-11

    In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.

  2. Collective Correlations of Brodmann Areas fMRI Study with RMT-Denoising

    OpenAIRE

    Burda, Zdzislaw; Kornelsen, Jennifer; Nowak, Maciej A.; Porebski, Bartosz; Sboto-Frankenstein, Uta; Tomanek, Boguslaw; Tyburczyk, Jacek

    2013-01-01

    We study collective behavior of Brodmann regions of human cerebral cortex using functional Magnetic Resonance Imaging (fMRI) and Random Matrix Theory (RMT). The raw fMRI data is mapped onto the cortex regions corresponding to the Brodmann areas with the aid of the Talairach coordinates. Principal Component Analysis (PCA) of the Pearson correlation matrix for 41 different Brodmann regions is carried out to determine their collective activity in the idle state and in the active state stimulated...

  3. SIGNATURES OF MRI-DRIVEN TURBULENCE IN PROTOPLANETARY DISKS: PREDICTIONS FOR ALMA OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Jacob B. [Department of Space Studies, Southwest Research Institute, Boulder, CO 80302 (United States); Hughes, A. Meredith; Flaherty, Kevin M. [Astronomy Department, Van Vleck Observatory, Wesleyan University, 96 Foss Hill Dr., Middletown, CT 06459 (United States); Bai, Xue-Ning [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., MS-51, Cambridge, MA 02138 (United States); Armitage, Philip J., E-mail: jbsimon.astro@gmail.com [JILA, University of Colorado and NIST, 440 UCB, Boulder, CO 80309-0440 (United States)

    2015-08-01

    Spatially resolved observations of molecular line emission have the potential to yield unique constraints on the nature of turbulence within protoplanetary disks. Using a combination of local non-ideal magnetohydrodynamics (MHD) simulations and radiative transfer calculations, tailored to properties of the disk around HD 163296, we assess the ability of ALMA to detect turbulence driven by the magnetorotational instability (MRI). Our local simulations show that the MRI produces small-scale turbulent velocity fluctuations that increase in strength with height above the mid-plane. For a set of simulations at different disk radii, we fit a Maxwell–Boltzmann distribution to the turbulent velocity and construct a turbulent broadening parameter as a function of radius and height. We input this broadening into radiative transfer calculations to quantify observational signatures of MRI-driven disk turbulence. We find that the ratio of the peak line flux to the flux at line center is a robust diagnostic of turbulence that is only mildly degenerate with systematic uncertainties in disk temperature. For the CO(3–2) line, which we expect to probe the most magnetically active slice of the disk column, variations in the predicted peak-to-trough ratio between our most and least turbulent models span a range of approximately 15%. Additional independent constraints can be derived from the morphology of spatially resolved line profiles, and we estimate the resolution required to detect turbulence on different spatial scales. We discuss the role of lower optical depth molecular tracers, which trace regions closer to the disk mid-plane where velocities in MRI-driven models are systematically lower.

  4. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque

    International Nuclear Information System (INIS)

    Broisat, A.

    2005-04-01

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, 201 Tl presents some drawbacks. 99m Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of 99m Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, 99m Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  5. Determination of the lysosomal role in tumor accumulation of 67Ga by dual-tracer studies

    International Nuclear Information System (INIS)

    Ando, Atsushi; Ando, Itsuko; Hiraki, Tatsunosuke; Yamada, Norihisa; Hisada, Kinichi

    1989-01-01

    The lysosomal role in tumor accumulation of 67 Ga was determined by dual-tracer( 67 Ga and 46 Sc) studies. It became clear that 67 Ga essentially did not accumulate in the tumor lysosome, and that the lysosome did not play a major role in tumor accumulation of 67 Ga. In addition, it was revealed that tumor lysosome was hardly disrupted at all in some phases of fractionation procedures. (author)

  6. Tracer tests - possibilities and limitations. Experience from SKB fieldwork: 1977-2007

    Energy Technology Data Exchange (ETDEWEB)

    Loefgren, Martin; Crawford, James; Elert, Mark (Kemakta Konsult AB, Stockholm (SE))

    2007-09-15

    Tracer tests have played, and still play, a central role in investigations relating to the understanding of radionuclide retention processes in the field. At present there is a debate within the scientific community concerning how, and to what extent, tracer tests can be used to evaluate large-scale and long-term transport and retardation of radionuclides and other solutes of interest for Safety Assessment of repositories for spent nuclear fuel. In this report the SKB fieldwork on tracer tests performed at Swedish sites from 1977 to 2007 is described and discussed. Furthermore, the knowledge and process understanding evolved during the decades of radionuclide transport experiments and modelling within the SKB programme is summarised. One of the main objectives of this report is to discuss what data and knowledge can be extracted from different in situ tests in a robust fashion. Given the level of complexity associated with transport processes that may occur over the timescale of a tracer test, the utility of tracer tests is considered in the context of evidence-based interpretations of data which we characterise in the form of a sequence of questions of increasing complexity. The complexity of this sequence ranges from whether connection can be confirmed between injection and withdrawal points to whether quantitative data can be extrapolated from a tracer test to be subsequently used in Safety Assessment. The main findings of this report are that: Field scale tracer tests can confirm flow connectivity. Field scale tracer tests confirm the existence of retention. Field scale tracer tests alone can only broadly substantiate our process understanding. However, if performing extensive Site Characterisation and integrating the tracer test results with the full range of geoscientific information available, much support can be given to our process understanding. Field scale tracer tests can deliver the product of the material property group MPG and the F-factor, valid

  7. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  8. Clinical studies of cerebral arteriosclerosis in diabetic subjects. Analysis with brain MRI study

    International Nuclear Information System (INIS)

    Ohashi, Makoto; Tanahashi, Hideo; Nomura, Makoto; Yamada, Yoshio; Abe, Hiroshi.

    1994-01-01

    In order to investigate the clinical characteristics of cerebral arteriosclerosis in diabetic subjects, brain MRI studies were conducted in diabetic patients and healthy subjects. The subjects were 93 diabetic patients without symptoms and signs of cerebral infarction (49 males and 44 females) with a mean age of 59 years and 73 healthy subjects (43 males and 30 females) with a mean age of 57 years. The MRI studies were performed on a General Electric 1.5-T signa system. The spin-echo technique (T2-weighted image) was used with a pulse repetition time (TR) of 2,500 msec and echo time (TE) of 80 msec. The quantitative evaluation of cerebral infarction was assessed using personal computer and image-scanner. By MRI, the incidence of cerebral infarction in diabetic patients was significantly higher than that in healthy subjects (30.1% vs. 13.7%, respectively, p<0.05). The mean age of the diabetic patients with cerebral infarctions was higher than that of those without cerebral infarctions. Hypertension and diabetic nephropathy were present more frequently in the subjects with cerebral infarctions. These data suggest that it is important to delay the onset and slow the progression of cerebral infarction in diabetic patients by strict blood glucose control and management of blood pressure. (author)

  9. Use of (3H) and (125I) tracers in steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1975-01-01

    The comparative use of 3 H and 125 I tracers in steroid radioimmunoassays will be discussed around the following points: - 3 H. Advantages: they can be purchased commercially and have a long shelf-life. Disadvantages: they may have reduced affinity for antibodies due to ''isotope effects''; the counting of β-emitters is more expensive and difficult; 3 H tracers are not available for all steroids. - 125 I. Advantages: gamma-counting is cheaper, simpler and more precise; 125 I tracers may have higher affinity for antibodies than unlabelled steroids; 125 I can be used to label any steroid. Disadvantages: 125 I tracers have a limited shelf-life (n.b. six months for 125 I histamine tracers). The high affinity of some tracers will be a big disadvantage if the unlabelled steroid cannot compete effectively

  10. A New Kind of Single-Well Tracer Test for Assessing Subsurface Heterogeneity

    Science.gov (United States)

    Hansen, S. K.; Vesselinov, V. V.; Lu, Z.; Reimus, P. W.; Katzman, D.

    2017-12-01

    Single-well injection-withdrawal (SWIW) tracer tests have historically been interpreted using the idealized assumption of tracer path reversibility (i.e., negligible background flow), with background flow due to natural hydraulic gradient being an un-modeled confounding factor. However, we have recently discovered that it is possible to use background flow to our advantage to extract additional information about the subsurface. To wit: we have developed a new kind of single-well tracer test that exploits flow due to natural gradient to estimate the variance of the log hydraulic conductivity field of a heterogeneous aquifer. The test methodology involves injection under forced gradient and withdrawal under natural gradient, and makes use of a relationship, discovered using a large-scale Monte Carlo study and machine learning techniques, between power law breakthrough curve tail exponent and log-hydraulic conductivity variance. We will discuss how we performed the computational study and derived this relationship and then show an application example in which our new single-well tracer test interpretation scheme was applied to estimation of heterogeneity of a formation at the chromium contamination site at Los Alamos National Laboratory. Detailed core hole records exist at the same site, from which it was possible to estimate the log hydraulic conductivity variance using a Kozeny-Carman relation. The variances estimated using our new tracer test methodology and estimated by direct inspection of core were nearly identical, corroborating the new methodology. Assessment of aquifer heterogeneity is of critical importance to deployment of amendments associated with in-situ remediation strategies, since permeability contrasts potentially reduce the interaction between amendment and contaminant. Our new tracer test provides an easy way to obtain this information.

  11. On interpreting studies of tracer transport by deep cumulus convection and its effects on atmospheric chemistry

    Directory of Open Access Journals (Sweden)

    M. G. Lawrence

    2008-10-01

    Full Text Available Global chemistry-transport models (CTMs and chemistry-GCMs (CGCMs generally simulate vertical tracer transport by deep convection separately from the advective transport by the mean winds, even though a component of the mean transport, for instance in the Hadley and Walker cells, occurs in deep convective updrafts. This split treatment of vertical transport has various implications for CTM simulations. In particular, it has led to a misinterpretation of several sensitivity simulations in previous studies in which the parameterized convective transport of one or more tracers is neglected. We describe this issue in terms of simulated fluxes and fractions of these fluxes representing various physical and non-physical processes. We then show that there is a significant overlap between the convective and large-scale mean advective vertical air mass fluxes in the CTM MATCH, and discuss the implications which this has for interpreting previous and future sensitivity simulations, as well as briefly noting other related implications such as numerical diffusion.

  12. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  13. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    International Nuclear Information System (INIS)

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. (paper)

  14. Tracer dispersion in two-dimensional rough fractures.

    Science.gov (United States)

    Drazer, G; Koplik, J

    2001-05-01

    Tracer diffusion and hydrodynamic dispersion in two-dimensional fractures with self-affine roughness are studied by analytic and numerical methods. Numerical simulations were performed via the lattice-Boltzmann approach, using a boundary condition for tracer particles that improves the accuracy of the method. The reduction in the diffusive transport, due to the fractal geometry of the fracture surfaces, is analyzed for different fracture apertures. In the limit of small aperture fluctuations we derive the correction to the diffusive coefficient in terms of the tortuosity, which accounts for the irregular geometry of the fractures. Dispersion is studied when the two fracture surfaces are simply displaced normally to the mean fracture plane and when there is a lateral shift as well. Numerical results are analyzed using the Lambda parameter, related to convective transport within the fracture, and simple arguments based on lubrication approximation. At very low Péclet number, in the case where fracture surfaces are laterally shifted, we show using several different methods that convective transport reduces dispersion.

  15. In-EDTA as activable tracer in hydrogeological investigations

    International Nuclear Information System (INIS)

    Stanescu, S.P.; Gaspar, E.; Spiridon, S.; Farcasiu, O.M.; Catilina, R.

    1982-12-01

    Two experiments are presented, on the possibilities of the use of indium in the form of the In-EDTA complex, as an activable tracer for hydrogeological studies. The determination of indium concentrations in the sampled water has been carried out by using the coprecipitation of indium with bismuth hydroxide, the neutron activation at the VVR-S reactor of the Institute for Nuclear Physics and Engineering - Bucharest and the measurement on the 417.0 keV line of sup(116m)In with the Ge(Li) spectrometric device. The advantages of the utilization of In-EDTA as a tracer for marking large volumes of water and of some long transit waters (of the order of months) have resulted. (authors)

  16. Contributions to hydrological tracer methods and their application

    International Nuclear Information System (INIS)

    1982-04-01

    The activities of the Institut fuer Radiohydrometrie of the GSF are mainly devoted to the field of environmental research studying the quality, use and protection from pollution of drinking water which has become scarce in many parts of the world. The knowledge and experience of a variety of scientific disciplines are combined to the common task of developing new tracer methods and selecting suitable hydrogeological methods to allow quantitative studies of the hydrological cycle, from rainfall to surface or sub-surface run-off. The tracers used in these studies are for the most part stable, natural radioisotopes occurring in the hydrological cycle, as well as fluorescent dyes or radionuclides for water labelling. The contributions collected in this volume are grouped according to the above outline of tasks and present a survey of current methods and measurements, illustrating their efficiency in solving hydrological problems. (orig./RW) [de

  17. Design and utilisation of protocols to characterise dynamic PET uptake of two tracers using basis pursuit

    Science.gov (United States)

    Bell, Christopher; Puttick, Simon; Rose, Stephen; Smith, Jye; Thomas, Paul; Dowson, Nicholas

    2017-06-01

    Imaging using more than one biological process using PET could be of great utility, but despite previously proposed approaches to dual-tracer imaging, it is seldom performed. The alternative of performing multiple scans is often infeasible for clinical practice or even in research studies. Dual-tracer PET scanning allows for multiple PET radiotracers to be imaged within the same imaging session. In this paper we describe our approach to utilise the basis pursuit method to aid in the design of dual-tracer PET imaging experiments, and later in separation of the signals. The advantage of this approach is that it does not require a compartment model architecture to be specified or even that both signals are distinguishable in all cases. This means the method for separating dual-tracer signals can be used for many feasible and useful combinations of biology or radiotracer, once an appropriate scanning protocol has been decided upon. Following a demonstration in separating the signals from two consecutively injected radionuclides in a controlled experiment, phantom and list-mode mouse experiments demonstrated the ability to test the feasibility of dual-tracer imaging protocols for multiple injection delays. Increases in variances predicted for kinetic macro-parameters V D and K I in brain and tumoral tissue were obtained when separating the synthetically combined data. These experiments confirmed previous work using other approaches that injections delays of 10-20 min ensured increases in variance were kept minimal for the test tracers used. On this basis, an actual dual-tracer experiment using a 20 min delay was performed using these radio tracers, with the kinetic parameters (V D and K I) extracted for each tracer in agreement with the literature. This study supports previous work that dual-tracer PET imaging can be accomplished provided certain constraints are adhered to. The utilisation of basis pursuit techniques, with its removed need to specify a model

  18. Uptake and transport of positron-emitting tracer in plants

    Energy Technology Data Exchange (ETDEWEB)

    Kume, Tamikazu; Matsuhashi, Shinpei; Shimazu, Masamitsu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; and others

    1997-03-01

    The transport of a positron-emitting isotope introduced into a plant was dynamically followed by a special observation apparatus called `Positron-Emitting Tracer Imaging System`. In the system, annihilation {gamma}-rays from the positron emitter are detected with two planer detectors (5 x 6 cm square). The water containing ca. 5 MBq/ml of {sup 18}F was fed to the cut stem of soybean for 2 min and then the images of tracer activity were recorded for 30 - 50 min. When the midrib of a leaf near the petiole was cut just before measurement, the activity in the injured leaf was decreased but detected even at the apex. This result suggests that the damaged leaf recovered the uptake of water through the lamina. Maximum tracer activities in leaves of unirradiated plant were observed within 10 min, whereas those of irradiated plant at 100 Gy were observed after over 25 min. The final activity of irradiated plant after 30 min was lower than that of unirradiated plant. In case of beans, there was a difference in the absorption behavior of the {sup 18}F-labeled water between unirradiated and irradiated samples. These results show that the system is effective to observe the uptake and transportation of water containing positron emitting tracer for the study of damage and recovery functions of plants. (author)

  19. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  20. Focuss algorithm application in kinetic compartment modeling for PET tracer

    International Nuclear Information System (INIS)

    Huang Xinrui; Bao Shanglian

    2004-01-01

    Molecular imaging is in the process of becoming. Its application mostly depends on the molecular discovery process of imaging probes and drugs, from the mouse to the patient, from research to clinical practice. Positron emission tomography (PET) can non-invasively monitor . pharmacokinetic and functional processes of drugs in intact organisms at tracer concentrations by kinetic modeling. It has been known that for all biological systems, linear or nonlinear, if the system is injected by a tracer in a steady state, the distribution of the tracer follows the kinetics of a linear compartmental system, which has sums of exponential solutions. Based on the general compartmental description of the tracer's fate in vivo, we presented a novel kinetic modeling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET), which can determine a parsimonious model consisting with the measured data. This kinetic modeling technique allows for estimation of parametric images from a voxel based analysis and requires no a priori decision about the tracer's fate in vivo, instead determining the most appropriate model from the information contained within the kinetic data. Choosing a set of exponential functions, convolved with the plasma input function, as basis functions, the time activity curve of a region or a pixel can be written as a linear combination of the basis functions with corresponding coefficients. The number of non-zero coefficients returned corresponds to the model order which is related to the number of tissue compartments. The system macro parameters are simply determined using the focal underdetermined system solver (FOCUSS) algorithm. The FOCUSS algorithm is a nonparametric algorithm for finding localized energy solutions from limited data and is a recursive linear estimation procedure. FOCUSS algorithm usually converges very fast, so demands a few iterations. The effectiveness is verified by simulation and clinical

  1. Radiation induced currents in MRI RF coils: application to linac/MRI integration

    Science.gov (United States)

    Burke, B.; Fallone, B. G.; Rathee, S.

    2010-02-01

    The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integrated systems, the radiofrequency (RF) coils of MRI will be irradiated with radiation pulses from the linac. The effect of pulsed radiation on MRI radio frequency (RF) coils is not known and must be studied. The instantaneous radiation induced current (RIC) in two different MRI RF coils were measured and presented. The frequency spectra of the induced currents were calculated. Some basic characterization of the RIC was also done: isolation of the RF coil component responsible for RIC, dependence of RIC on dose rate, and effect of wax buildup placed on coil on RIC. Both the time and frequency characteristics of the RIC were seen to vary with the MRI RF coil used. The copper windings of the RF coils were isolated as the main source of RIC. A linear dependence on dose rate was seen. The RIC was decreased with wax buildup, suggesting an electronic disequilibrium as the cause of RIC. This study shows a measurable RIC present in MRI RF coils. This unwanted current could be possibly detrimental to the signal to noise ratio in MRI and produce image artifacts.

  2. Differentiation of periapical granulomas and cysts by using dental MRI: a pilot study.

    Science.gov (United States)

    Juerchott, Alexander; Pfefferle, Thorsten; Flechtenmacher, Christa; Mente, Johannes; Bendszus, Martin; Heiland, Sabine; Hilgenfeld, Tim

    2018-05-17

    The purpose of this pilot study was to evaluate whether periapical granulomas can be differentiated from periapical cysts in vivo by using dental magnetic resonance imaging (MRI). Prior to apicoectomy, 11 patients with radiographically confirmed periapical lesions underwent dental MRI, including fat-saturated T2-weighted (T2wFS) images, non-contrast-enhanced T1-weighted images with and without fat saturation (T1w/T1wFS), and contrast-enhanced fat-saturated T1-weighted (T1wFS+C) images. Two independent observers performed structured image analysis of MRI datasets twice. A total of 15 diagnostic MRI criteria were evaluated, and histopathological results (6 granulomas and 5 cysts) were compared with MRI characteristics. Statistical analysis was performed using intraclass correlation coefficient (ICC), Cohen's kappa (κ), Mann-Whitney U-test and Fisher's exact test. Lesion identification and consecutive structured image analysis was possible on T2wFS and T1wFS+C MRI images. A high reproducibility was shown for MRI measurements of the maximum lesion diameter (intraobserver ICC = 0.996/0.998; interobserver ICC = 0.997), for the "peripheral rim" thickness (intraobserver ICC = 0.988/0.984; interobserver ICC = 0.970), and for all non-quantitative MRI criteria (intraobserver-κ = 0.990/0.995; interobserver-κ = 0.988). In accordance with histopathological results, six MRI criteria allowed for a clear differentiation between cysts and granulomas: (1) outer margin of lesion, (2) texture of "peripheral rim" in T1wFS+C, (3) texture of "lesion center" in T2wFS, (4) surrounding tissue involvement in T2wFS, (5) surrounding tissue involvement in T1wFS+C and (6) maximum "peripheral rim" thickness (all: P periapical cysts and granulomas in vivo. Thus, MRI may substantially improve treatment strategies and help to avoid unnecessary surgery in apical periodontitis.

  3. PET/MRI of metabolic activity in osteoarthritis: A feasibility study.

    Science.gov (United States)

    Kogan, Feliks; Fan, Audrey P; McWalter, Emily J; Oei, Edwin H G; Quon, Andrew; Gold, Garry E

    2017-06-01

    To evaluate positron emission tomography / magnetic resonance imaging (PET/MRI) knee imaging to detect and characterize osseous metabolic abnormalities and correlate PET radiotracer uptake with osseous abnormalities and cartilage degeneration observed on MRI. Both knees of 22 subjects with knee pain or injury were scanned at one timepoint, without gadolinium, on a hybrid 3.0T PET-MRI system following injection of 18 F-fluoride or 18 F-fluorodeoxyglucose (FDG). A musculoskeletal radiologist identified volumes of interest (VOIs) around bone abnormalities on MR images and scored bone marrow lesions (BMLs) and osteophytes using a MOAKS scoring system. Cartilage appearance adjacent to bone abnormalities was graded with MRI-modified Outerbridge classifications. On PET standardized uptake values (SUV) maps, VOIs with SUV greater than 5 times the SUV in normal-appearing bone were identified as high-uptake VOI (VOI High ). Differences in 18 F-fluoride uptake between bone abnormalities, BML, and osteophyte grades and adjacent cartilage grades on MRI were identified using Mann-Whitney U-tests. SUV max in all subchondral bone lesions (BML, osteophytes, sclerosis) was significantly higher than that of normal-appearing bone on MRI (P subchondral bone on MRI. Furthermore, many small grade 1 osteophytes (40 of 82 [49%]), often described as the earliest signs of osteoarthritis (OA), did not show high uptake. Lastly, PET SUV max in subchondral bone adjacent to grade 0 cartilage was significantly lower compared to that of grades 1-2 (P subchondral bone, which appear normal on MRI. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;45:1736-1745. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    Science.gov (United States)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  5. Studies on the reliability of high-field intra-operative MRI in brain glioma resection

    Directory of Open Access Journals (Sweden)

    Zhi-jun SONG

    2011-07-01

    Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.

  6. Prediction of iodine-131 biokinetics and radiation doses from therapy on the basis of tracer studies: an important question for therapy planning in nuclear medicine.

    Science.gov (United States)

    Willegaignon, José; Pelissoni, Rogério A; Lima, Beatriz C G D; Sapienza, Marcelo T; Coura-Filho, George B; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from

  7. Modelling tracer transport in fractured rock at Stripa

    International Nuclear Information System (INIS)

    Herbert, A.

    1992-01-01

    We present the results of a modelling study, making predictions for tracer transport experiments carried out within the H-zone feature in the Stripa mine. We use a direct fracture network approach to represent the system of interconnected flow-conducting fractures comprising this zone. It is a highly fractured granite, and our fracture-network models include up to 60000 fractures. We have had to develop efficient algorithms to calculate the flow and transport through these networks; these techniques are described and justified. The first stage of modelling addressed two saline injection experiments. The results of these were known to us and so in addition to 'predicting' the results of these experiments, we used them to calibrate a flow model of the experimental site. This model was then used to make true 'blind' predictions for a set of tracer experiments carried out in the natural head-field, caused by an open drift. Where our flow model was good, our predictions were found to be very accurate, explaining the dispersion in the tracer breakthrough in terms of the fracture network geometry. Discrepancies for experiments in less well characterised regions of the H-zone are presented, and we suggest that the errors in these predictions are a consequence of the inaccuracies of the flow-field. We have demonstrated the use of large-scale fracture network modelling. It has proved very successful, and made very accurate predictions of field experiments carried out at the Stripa mine. The measured dispersion of tracers can be accounted for by the geometry of the fracture network flow system. (14 refs.) (au)

  8. Fractal tracer distributions in turbulent field theories

    DEFF Research Database (Denmark)

    Hansen, J. Lundbek; Bohr, Tomas

    1998-01-01

    We study the motion of passive tracers in a two-dimensional turbulent velocity field generated by the Kuramoto-Sivashinsky equation. By varying the direction of the velocity-vector with respect to the field-gradient we can continuously vary the two Lyapunov exponents for the particle motion and t...

  9. Synthesis of radiolabelled organic compounds for use as water tracers in oil reservoirs

    International Nuclear Information System (INIS)

    Eriksen, D.Oe.; Bjoernstad, V.

    1999-01-01

    Injection of water into oil containing strata to maintain field pressure and to replace oil is usually the primary choice to enhance oil-recovery. Use of tracer methods is becoming an important part of the oil companies' basis for making economical decisions. Such water tracing requires passive tracers, i.e. compounds that behave exactly like the substance studied under the conditions of interest. This implies that a water-tracer in a water-flooded oil-field must fulfil requirements like no absorption to reservoir rock, no partitioning (or distribution) with respect to the other fluids present, long time thermal stability, microbial resistance and high detectability. In addition, the tracer compound has to be environmentally acceptable and available at a reasonable cost. Among the extensive number of compounds tested according to these criteria in the laboratory we have qualified four compounds as tracers for water in oil reservoirs. For three of them we propose radiolabelling syntheses with 14 C as radioactive label to lower detection limits. The compounds are benzene 1,2- and 1,3-dicarboxylic acids and benzene 1,3,5-tricarboxylic acid. (author)

  10. Radon as tracer to identify discharge sections at Juatuba basin

    International Nuclear Information System (INIS)

    Chagas, Claudio Jose; Ferreira, Vinicius Verna Magalhaes; Fonseca, Raquel Luisa Mageste; Rocha, Zildete; Moreira, Rubens Martins; Lemos, Nayron Cosme; Menezes, Angela de Barros Correia; Santos, Talita Oliveira

    2015-01-01

    The use of natural tracers in hydrological studies is a very useful tool, being applied in several studies. One of these tracers is the radon, 222 Rn, noble gas derived from natural sources, been found in all underground waters, as a product of radioactive decay of the 226 Ra. This gas can be found in the air, water, rocks or soil. In this paper, the 222 Rn detection in surface water was used as tracer in order to identify aquifer discharge sections in surface water at the Fundao stream, which belongs to the Juatuba river basin, through the second semester of 2014 and the first semester of 2015, in three sampling campaigns. The 222 Rn measurements at Fundao stream were carried out using the equipment RAD 7. The results showed that 222 Rn is present in some sections of the water course suggesting that there is a connection between groundwater and surface water. It also justifies the variation in the water level in the stream, recorded by a fluviometric station. (author)

  11. Radon as tracer to identify discharge sections at Juatuba basin

    Energy Technology Data Exchange (ETDEWEB)

    Chagas, Claudio Jose; Ferreira, Vinicius Verna Magalhaes; Fonseca, Raquel Luisa Mageste; Rocha, Zildete; Moreira, Rubens Martins; Lemos, Nayron Cosme; Menezes, Angela de Barros Correia, E-mail: vvmf@cdtn.br, E-mail: rlmf@cdtn.br, E-mail: cjc@cdtn.br, E-mail: rochaz@cdtn.br, E-mail: rubens@cdtn.br, E-mail: menezes@cdtn.br, E-mail: lemosnc@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, Talita Oliveira, E-mail: talitaolsantos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Departamento de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2015-07-01

    The use of natural tracers in hydrological studies is a very useful tool, being applied in several studies. One of these tracers is the radon, {sup 222}Rn, noble gas derived from natural sources, been found in all underground waters, as a product of radioactive decay of the {sup 226}Ra. This gas can be found in the air, water, rocks or soil. In this paper, the {sup 222}Rn detection in surface water was used as tracer in order to identify aquifer discharge sections in surface water at the Fundao stream, which belongs to the Juatuba river basin, through the second semester of 2014 and the first semester of 2015, in three sampling campaigns. The {sup 222}Rn measurements at Fundao stream were carried out using the equipment RAD 7. The results showed that {sup 222}Rn is present in some sections of the water course suggesting that there is a connection between groundwater and surface water. It also justifies the variation in the water level in the stream, recorded by a fluviometric station. (author)

  12. Green River air quality model development: meteorological and tracer data, July/August 1982 field study in Brush Valley, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, C.D.; Lee, R.N.; Orgill, M.M.; Zak, B.D.

    1984-06-01

    Meteorological and atmospheric tracer studies were conducted during a 3-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The objective of the field experiments was to obtain data to evaluate a model, called VALMET, developed at PNL to predict dispersion of air pollutants released from an elevated stack located within a deep mountain valley in the post-sunrise temperature inversion breakup period. Three tracer experiments were conducted in the valley during the 2-week period. In these experiments, sulfur hexafluoride (SF/sub 6/) was released from a height of approximately 100 m, beginning before sunrise and continuing until the nocturnal down-valley winds reversed several hours after sunrise. Dispersion of the sulfur hexafluoride after release was evaluated by measuring SF/sub 6/ concentrations in ambient air samples taken from sampling devices operated within the valley up to about 8 km down valley from the source. An instrumented research aircraft was also used to measure concentrations in and above the valley. Tracer samples were collected using a network of radio-controlled bag sampling stations, two manually operated gas chromatographs, a continuous SF/sub 6/ monitor, and a vertical SF/sub 6/ profiler. In addition, basic meteorological data were collected during the tracer experiments. Frequent profiles of vertical wind and temperature structure were obtained with tethered balloons operated at the release site and at a site 7.7 km down the valley from the release site. 10 references, 63 figures, 50 tables.

  13. Study on development of evaluation technique of in-situ tracer test in Horonobe Underground Research Laboratory project (Contract research)

    International Nuclear Information System (INIS)

    Yokota, Hideharu; Amano, Kenji; Maekawa, Keisuke; Kunimaru, Takanori; Naemura, Yumi; Ijiri, Yuji; Motoshima, Takayuki; Suzuki, Shunichi; Teshima, Kazufumi

    2013-06-01

    In the Horonobe Underground Research Laboratory Project, in-situ tracer tests are valuable and important as the investigations to obtain the mass transportation data of fractures in hostrock. However, it is difficult that the in-situ tests are executed under various conditions due to long test period and the tests results are evaluated about permeable heterogeneity in a fracture and/or scale effects. In this study, a number of tracer tests are simulated in a fictitious single plate fracture generated on computer. And the transport parameters are identified by fitting one- and two-dimensional models to the breakthrough curves obtained from the simulations in order to investigate the applicability of these models to the evaluation of in-situ tracer test. As a result, one-dimensional model yields larger longitudinal dispersion length than two-dimensional model in the both cases of homogeneous and heterogeneous hydraulic conductivity fields of the fictitious fracture. This is because that the effect of transverse dispersion has to be included in the longitudinal dispersion length parameter in the one-dimensional model. It is also found that the larger dipole ratio and the larger natural groundwater flow crossing the flow generated between two boreholes make the identified longitudinal dispersion length larger. And, the longitudinal dispersion length identified from a tracer test is smaller and/or larger than the macroscopic longitudinal dispersion length identified from whole fracture. It is clarified that these are occurred by shorter or longer distance between boreholes compare to the correlation length of geostatistical heterogeneity of fictitious fracture. (author)

  14. Positron emission tomography with additional γ-ray detectors for multiple-tracer imaging.

    Science.gov (United States)

    Fukuchi, Tomonori; Okauchi, Takashi; Shigeta, Mika; Yamamoto, Seiichi; Watanabe, Yasuyoshi; Enomoto, Shuichi

    2017-06-01

    Positron emission tomography (PET) is a useful imaging modality that quantifies the physiological distributions of radiolabeled tracers in vivo in humans and animals. However, this technique is unsuitable for multiple-tracer imaging because the annihilation photons used for PET imaging have a fixed energy regardless of the selection of the radionuclide tracer. This study developed a multi-isotope PET (MI-PET) system and evaluated its imaging performance. Our MI-PET system is composed of a PET system and additional γ-ray detectors. The PET system consists of pixelized gadolinium orthosilicate (GSO) scintillation detectors and has a ring geometry that is 95 mm in diameter with an axial field of view of 37.5 mm. The additional detectors are eight bismuth germanium oxide (BGO) scintillation detectors, each of which is 50 × 50 × 30 mm 3 , arranged into two rings mounted on each side of the PET ring with a 92-mm-inner diameter. This system can distinguish between different tracers using the additional γ-ray detectors to observe prompt γ-rays, which are emitted after positron emission and have an energy intrinsic to each radionuclide. Our system can simultaneously acquire double- (two annihilation photons) and triple- (two annihilation photons and a prompt γ-ray) coincidence events. The system's efficiency for detecting prompt de-excitation γ-rays was measured using a positron-γ emitter, 22 Na. Dual-radionuclide ( 18 F and 22 Na) imaging of a rod phantom and a mouse was performed to demonstrate the performance of the developed system. Our system's basic performance was evaluated by reconstructing two images, one containing both tracers and the other containing just the second tracer, from list-mode data sets that were categorized by the presence or absence of the prompt γ-ray. The maximum detection efficiency for 1275 keV γ-rays emitted from 22 Na was approximately 7% at the scanner's center, and the minimum detection efficiency was 5.1% at the edge of

  15. Analysis of some laboratory tracer runs in natural fissures

    International Nuclear Information System (INIS)

    Moreno, L.; Neretnieks, I.

    1984-01-01

    Tracer tests in natural fissures performed in the laboratory are analysed by means of fitting two different models. In the experiments, sorbing and non-sorbing tracers were injected into a natural fissure running parallel to the axis of a drill core. The models take into account advection, diffusion into the rock matrix, sorption onto the rock surface and dispersion. For the last mechanism, one of the models considers hydrodynamic dispersion while the other model assumes channeling dispersion. The models take into account time delays in the inlet and outlet channels. The dispersion characteristics and water residence time were determined from the experiments with non-sorbing tracers. Surface and volume sorption coefficients and data on diffusion into the rock matrix were determined for the sorbing tracers. The results are compared with values independently determined in the laboratory. Good agreement was obtained using either model. When these models are used for prediction of tracer transport over larger distances, the results will depend on the model. The model with channeling dispersion will show a greater dispersion than the model with hydrodynamic dispersion. (author)

  16. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    Energy Technology Data Exchange (ETDEWEB)

    Itatani, R., E-mail: banguliao@gmail.com [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Namimoto, T. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Atsuji, S.; Katahira, K.; Morishita, S. [Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitani, K.; Hamada, Y. [Department of Urology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitaoka, M. [Department of Pathology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Nakaura, T. [Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046 (Japan); Yamashita, Y. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan)

    2014-10-15

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy.

  17. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    International Nuclear Information System (INIS)

    Itatani, R.; Namimoto, T.; Atsuji, S.; Katahira, K.; Morishita, S.; Kitani, K.; Hamada, Y.; Kitaoka, M.; Nakaura, T.; Yamashita, Y.

    2014-01-01

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy

  18. Brain correlates of aesthetic expertise: A parametric fMRI study

    DEFF Research Database (Denmark)

    Kirk, Ulrich; Skov, Martin; Christensen, Mark Schram

    2009-01-01

    Several studies have demonstrated that acquired expertise influences aesthetic judgments. In this paradigm we used functional magnetic resonance imaging (fMRI) to study aesthetic judgments of visually presented architectural stimuli and control-stimuli (faces) for a group of architects and a grou...

  19. Candidate Biomarkers in Children with Autism Spectrum Disorder: A Review of MRI Studies

    Institute of Scientific and Technical Information of China (English)

    Dongyun Li; Hans-Otto Karnath; Xiu Xu

    2017-01-01

    Searching for effective biomarkers is one of the most challenging tasks in the research field of Autism Spectrum Disorder (ASD).Magnetic resonance imaging (MRI) provides a non-invasive and powerful tool for investigating changes in the structure,function,maturation,connectivity,and metabolism of the brain of children with ASD.Here,we review the more recent MRI studies in young children with ASD,aiming to provide candidate biomarkers for the diagnosis of childhood ASD.The review covers structural imaging methods,diffusion tensor imaging,resting-state functional MRI,and magnetic reso nance spectroscopy.Future advances in neuroimaging techniques,as well as cross-disciplinary studies and largescale collaborations will be needed for an integrated approach linking neuroimaging,genetics,and phenotypic data to allow the discovery of new,effective biomarkers.

  20. Clinical Study Preoperative Evaluation with f MRI of Patients with Intracranial Gliomas Ioannis

    International Nuclear Information System (INIS)

    Kapsalakis, Z.; Hadjigeorgiou, G.; Papadimitriou, A.; Kapsalaki, E.Z.; Fezoulidis, I.; Gotsis, E.D.; Verganelakis, D.; Toulas, P.; Chung, I.; Robinson, J.S.; Lee, J.P.; Fountas, K.N.; Fountas, K.N.

    2012-01-01

    Aggressive surgical resection constitutes the optimal treatment for intracranial gliomas. However, the proximity of a tumor to eloquent areas requires exact knowledge of its anatomic relationships to functional cortex. The purpose of our study was to evaluate f MRI’s accuracy by comparing it to intraoperative cortical stimulation (DCS) mapping. Material and Methods. Eighty-seven patients, with presumed glioma diagnosis, underwent preoperative fMRI and intraoperative DCS for cortical mapping during tumor resection. Findings of fMRI and DCS were considered concordant if the identified cortical centers were less than 5 mm apart. Pre and postoperative Karnofsky Performance Scale and Spitzer scores were recorded. A postoperative MRI was obtained for assessing the extent of resection. Results. The areas of interest were identified by f MRI and DCS in all participants. The concordance between f MRI and Dncs was 91.9% regarding sensory-motor cortex, 100% for visual cortex, and 85.4% for language. Data analysis showed that patients with better functional condition demonstrated higher concordance rates, while there also was a weak association between tumor grade and concordance rate. The mean extent of tumor resection was 96.7%. Conclusions. Functional MRI is a highly accurate preoperative methodology for sensory-motor mapping. However, in language mapping, DCS remains necessary for accurate localization

  1. Carbamazepine reduces memory induced activation of mesial temporal lobe structures: a pharmacological fMRI-study

    Directory of Open Access Journals (Sweden)

    Okujava Michael

    2001-11-01

    Full Text Available Abstract Background and Purpose It is not known whether carbamazepine (CBZ; a drug widely used in neurology and psychiatry influences the blood oxygenation level dependent (BOLD contrast changes induced by neuronal activation and measured by functional MRI (fMRI. We aimed to investigate the influence of CBZ on memory induced activation of the mesial temporal lobes in patients with symptomatic temporal lobe epilepsy (TLE. Material and Methods Twenty-one individual patients with refractory symptomatic TLE with different CBZ serum levels and 20 healthy controls were studied using BOLD fMRI. Mesial temporal lobe (MTL activation was induced by a task that is based on the retrieval of individually familiar visuo-spatial knowledge. The extent of significant MTL fMRI activation was measured and correlated with the CBZ serum level. Results In TLE patients, the extent of significant fMRI activation over both MTL was negatively correlated to the CBZ serum level (Spearman r = -0.654, P Conclusions In TLE patients, carbamazepine reduces the fMRI-detectable changes within the mesial temporal lobes as induced by effortful memory retrieval. FMRI appears to be suitable to study the effects of chronic drug treatment in patients with epilepsy.

  2. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  3. 2007 California Aerosol Study: Evaluation of δ15N as a Tracer Of NOx Sources and Chemsitry

    Science.gov (United States)

    Katzman, T. L.

    2017-12-01

    Although stable isotopes of N are commonly used as a source tracer, how this tracer is applied is a point of contention. The "source" hypothesis argues that the δ15N value of NO3- reflects the δ15N value of NOx source inputs into the environment, and any observed variation is solely the result of differences in source contributions. Conversely, the "chemistry" hypothesis argues that N isotopes are influenced by chemical reactions, atmospheric or biologic processing, and post-depositional effects. Previous studies often apply the source hypothesis, writing off the chemistry hypothesis as "minor," but others have noted the impact chemistry should has on δ15N values. Given the known complications, this work seeks to assess the use of stable isotopes as tracers, specifically, the assumption that the δ15N value is a tracer of source alone without significant influence from chemical reactions. If the "source" hypothesis is correct, source emission data, known source δ15N values, and isotope mass balance should be able to approximate measured δ15NNO3 values and determine the δ15N value associated with wildfire derived NOx, which is currently unknown. Significant deviations from observed values would support the significance of equilibrium and kinetic isotope effects associated with chemical reactions and processing in the atmosphere. Aerosols collected in during 2007, emission data, and isotopic analysis were utilized to determine the utility of δ15N as tracer of NOx sources. San Diego, California is a coastal urban area influenced by sea salt aerosols, anthropogenic combustion emissions, and seasonal wildfires. Wildfires also have a significant influence on local atmospheric chemistry and 2007 was notable for being one of the worst fire seasons in the San Diego region on record. Isotopic analysis of collected NO3- has suggested that source δ15N values are likely not conserved as NOx is oxidized into NO3-. Given known source contributions and known δ15N values

  4. Radionuclides as tracers

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Importance of radioisotopes in medicine is because of their two characteristics: their biological behaviour is identical to their stable counterparts, and because they are radioactive their emissions can be detected by a suitable instrument. All isotopes of iodine will behave in the same way and will concentrate in the thyroid gland. There is no way of detecting the stable, natural iodine in the thyroid gland, but the presence of radioactive iodine can be detected externally in vivo by a detector. Thus, the radioactive iodine becomes a tracer, a sport of a spy, which mimics the behaviour of natural iodine and relays information to a detector. The radioactive tracers are popular because of the ease with which they can be detected in vivo and the fact that the measurement of their presence in the body can be in quantitative terms. The measurement can be very accurate and sensitive. Whenever the measurements can be done in vivo, the information is obtained in dynamic terms, as it is happening, as if the physiological events become transparent

  5. Noaa chlorofluorocarbon tracer program air and seawater measurements: 1986-1989. Data file

    International Nuclear Information System (INIS)

    Wisegarver, D.P.; Bullister, J.L.; Gammon, R.H.; Menzia, F.A.; Kelly, K.C.

    1993-04-01

    The NOAA Chlorofluorocarbon (CFC) Tracer Program at PMEL has been measuring the growing burden of these anthropogenic gases in the thermocline waters of the Pacific Ocean since 1980. The central goals of the NOAA CFC Tracer Program are to document the transient invasion of the CFC tracers into the Pacific Ocean, by means of repeat occupations of key hydrographic sections at 5-year intervals, and to interpret these changing distributions in terms of coupled ocean-atmosphere models. Studies are underway to use the CFC observations in model-validation studies, and to help develop predictive capabilities on the decade-to-century timescale. The report includes measurements of trichlorofluoromethane (CFC-11) and dichlorodifluoromethane (CFC-12) dissolved in seawater samples collected in the Pacific Ocean by the NOAA CFC Tracer Program on six cruises during the period of 1986-1989. Measurements of depth, pressure, salinity, temperature, and dissolved oxygen are included with the CFC data. Measurements of CFC-11 and CFC-12 in air samples collected along the cruise tracks are also included in the report. Data from the report are also available from the authors in digital format

  6. HLA-B27 and gender independently determine the likelihood of a positive MRI of the sacroiliac joints in patients with early inflammatory back pain: a 2-year MRI follow-up study

    NARCIS (Netherlands)

    van Onna, M.; Jurik, A. G.; van der Heijde, D.; van Tubergen, A.; Heuft-Dorenbosch, L.; Landewé, R.

    2011-01-01

    To describe how inflammation on MRI of the sacroiliac joints in patients with recent-onset inflammatory back pain (IBP) evolves over time, and to study determinants of activity on MRI of the sacroiliac joint. A 2-year follow-up study with annual MRI of the sacroiliac joints was conducted in patients

  7. Resting-state fMRI study of patients with fragile X syndrome

    Science.gov (United States)

    Isanova, E.; Petrovskiy, E.; Savelov, A.; Yudkin, D.; Tulupov, A.

    2017-08-01

    The study aimed to assess the neural activity of different brain regions in patients with fragile X syndrome (FXS) and the healthy volunteers by resting-state functional magnetic resonance imaging (fMRI) on a 1.5 T MRI Achieva scanner (Philips). Results: The fMRI study showed a DMN of brain function in patients with FXS, as well as in the healthy volunteers. Furthermore, it was found that a default mode network of the brain in patients with FXS and healthy volunteers does not have statistically significant differences (p>0.05), which may indicate that the basal activity of neurons in patients with FXS is not reduced. In addition, we have found a significant (pright inferior parietal and right angular gyrus in the resting state in patients with FXS. Conclusion: New data of functional status of the brain in patients with FXS were received. The significant increase in the resting state functional connectivity within the right inferior parietal and right angular gyrus (p<0.001) in patients with FXS was found.

  8. Enhanced Oil Recovery: Aqueous Flow Tracer Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Rovani; John Schabron

    2009-02-01

    A low detection limit analytical method was developed to measure a suite of benzoic acid and fluorinated benzoic acid compounds intended for use as tracers for enhanced oil recovery operations. Although the new high performance liquid chromatography separation successfully measured the tracers in an aqueous matrix at low part per billion levels, the low detection limits could not be achieved in oil field water due to interference problems with the hydrocarbon-saturated water using the system's UV detector. Commercial instrument vendors were contacted in an effort to determine if mass spectrometry could be used as an alternate detection technique. The results of their work demonstrate that low part per billion analysis of the tracer compounds in oil field water could be achieved using ultra performance liquid chromatography mass spectrometry.

  9. Dynamics and mechanics of bed-load tracer particles

    Directory of Open Access Journals (Sweden)

    C. B. Phillips

    2014-12-01

    Full Text Available Understanding the mechanics of bed load at the flood scale is necessary to link hydrology to landscape evolution. Here we report on observations of the transport of coarse sediment tracer particles in a cobble-bedded alluvial river and a step-pool bedrock tributary, at the individual flood and multi-annual timescales. Tracer particle data for each survey are composed of measured displacement lengths for individual particles, and the number of tagged particles mobilized. For single floods we find that measured tracer particle displacement lengths are exponentially distributed; the number of mobile particles increases linearly with peak flood Shields stress, indicating partial bed load transport for all observed floods; and modal displacement distances scale linearly with excess shear velocity. These findings provide quantitative field support for a recently proposed modeling framework based on momentum conservation at the grain scale. Tracer displacement is weakly negatively correlated with particle size at the individual flood scale; however cumulative travel distance begins to show a stronger inverse relation to grain size when measured over many transport events. The observed spatial sorting of tracers approaches that of the river bed, and is consistent with size-selective deposition models and laboratory experiments. Tracer displacement data for the bedrock and alluvial channels collapse onto a single curve – despite more than an order of magnitude difference in channel slope – when variations of critical Shields stress and flow resistance between the two are accounted for. Results show how bed load dynamics may be predicted from a record of river stage, providing a direct link between climate and sediment transport.

  10. Functional MRI studies of the neural mechanisms of human brain attentional networks

    International Nuclear Information System (INIS)

    Hao Jing; Li Kuncheng; Chen Qi; Wang Yan; Peng Xiaozhe; Zhou Xiaolin

    2005-01-01

    Objective: To identify the neural mechanisms of the anterior attention network (AAN) and posterior attention network (PAN) , investigate the possible interaction between them with event-related functional MRI(ER-fMRI). Methods: Eight right-handed healthy volunteers participated in the experiment designed with inhibition of return in visual orienting and Stroop color-word interference effect. The fMRI data were collected on Siemens 1.5 T Sonata MRI systems and analyzed by AFNI to generate the activation map. Results: The data sets from 6 of 8 subjects were used in the study. The functional localizations of the Stroop and IOR, which manifest the function of the AAN and PAN respectively, were consistent with previous imaging researches. On cued locations, left inferior parietal lobule (IPL), area MT/V5, right dorsolateral prefrontal cortex (DLPFC) and left anterior cingulated cortex (ACC) were significantly activated. On uncued locations, right superior parietal lobule (SPL) and bilateral area MT/V5 were significantly activated. Conclusion: The AAN exerts control over the PAN, while its function can be in turn modulated by the PAN. There are interaction between the AAN and PAN. In addition, it is also proved that ER-fMRI is a feasible method to revise preexisting cognitive model and theory. (authors)

  11. CityFlux perfluorocarbon tracer experiments

    Science.gov (United States)

    Petersson, F. K.; Martin, D.; White, I. R.; Henshaw, S. J.; Nickless, G.; Longley, I.; Percival, C. J.; Gallagher, M.; Shallcross, D. E.

    2010-07-01

    In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m. The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site. Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail. The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this. The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  12. Comparative studies of brain activation with MEG and functional MRI

    International Nuclear Information System (INIS)

    George, J.S.; Aine, C.J.; Sanders, J.A.; Lewine, J.D.; Caprihan, A.

    1993-01-01

    The past two years have witnessed the emergence of MRI as a functional imaging methodology. Initial demonstrations involved the injection of a paramagnetic contrast agent and required ultrafast echo planar imaging capability to adequately resolve the passage of the injected bolus. By measuring the local reduction in image intensity due to magnetic susceptibility, it was possible to calculate blood volume, which changes as a function of neural activation. Later developments have exploited endogenous contrast mechanisms to monitor changes in blood volume or in venous blood oxygen content. Recently, we and others have demonstrated that it is possible to make such measurements in a clinical imager, suggesting that the large installed base of such machines might be utilized for functional imaging. Although it is likely that functional MRI (fMRI) will subsume some of the clinical and basic neuroscience applications now touted for MEG, it is also clear that these techniques offer different largely complementary, capabilities. At the very least, it is useful to compare and cross-validate the activation maps produced by these techniques. Such studies will be valuable as a check on results of neuromagnetic distributed current reconstructions and will allow better characterization of the relationship between neurophysiological activation and associated hemodynamic changes. A more exciting prospect is the development of analyses that combine information from the two modalities to produce a better description of underlying neural activity than is possible with either technique in isolation. In this paper we describe some results from initial comparative studies and outline several techniques that can be used to treat MEG and fMRI data within a unified computational framework

  13. Use of sulfur hexafluoride and perfluorocarbon tracers in plutonium storage containers for leak detection

    International Nuclear Information System (INIS)

    Kung, J.K.

    1998-05-01

    This study involves an investigation of the feasibility of a tracer-based leak detection system for long-term interim plutonium storage. In particular, a protocol has been developed based on the use of inert tracers with varying concentrations in order to open-quotes fingerprintclose quotes or open-quotes tagclose quotes specific containers. A particular combination of tracers at specific ratios could be injected into the free volume of each container, allowing for the detection of leaks as well as determination of the location of leaking containers. Based on plutonium storage considerations, sulfur hexafluoride and four perfluorocarbon tracers were selected and should allow a wide range of viable fingerprinting combinations. A open-quotes high-lowclose quotes protocol which uses two distinct chromatographic peak areas or concentration levels, is recommended. Combinations of air exchange rates, detection durations, and detectability limits are examined in order to predict minimum tracer concentrations required for injection in storage containers

  14. An exploration of GPs' use of MRI: a critical incident study.

    Science.gov (United States)

    Robling, M; Kinnersley, P; Houston, H; Hourihan, M; Cohen, D; Hale, J

    1998-06-01

    Direct access to Magnetic Resonance Imaging (MRI) is becoming available to GPs in the UK, offering major benefits for the improved diagnosis and management of certain clinical conditions. Variations in usage of this service may be large, and effective locally produced guidelines are not currently available. The Department of General Practice is conducting a research programme to develop and evaluate methods to optimize MRI use by GPs. We aimed to describe the current use of MRI by GPs in South Glamorgan; to summarize their reasons for requesting MRI; and to produce criteria to assess the appropriateness of magnetic resonance (MR) scan requests. Using the critical incident technique, 25 GPs were interviewed about recent scans requested for patients with knee and lumbar spine complaints. A local panel of primary and secondary care doctors was convened to develop criteria for assessing MR scan requests. Sixty-two scan requests were discussed. Doctors' reasons for requesting MR scans were identified and classified. Reasons for requests included personal, contextual and biomedical variables. Fifteen patients (24%) were managed in primary care following MRI when otherwise they would have been referred. When referrals were made, GPs felt able to reinforce the request and occasionally to direct the patient somewhere more appropriate. The panel reviewed the interview data to produce objective criteria to assess scan requests. The criteria reflect the relative importance of non-biomedical variables in the decision to request MRI. The study identified those reasons which are important to GPs when requesting MR scans and the impact of this new technology upon patient management. Interview data have been used to inform locally developed consensus criteria, which will be made available as practice guidelines as the research programme progresses.

  15. Multilingualism and fMRI: Longitudinal Study of Second Language Acquisition

    Science.gov (United States)

    Andrews, Edna; Frigau, Luca; Voyvodic-Casabo, Clara; Voyvodic, James; Wright, John

    2013-01-01

    BOLD fMRI is often used for the study of human language. However, there are still very few attempts to conduct longitudinal fMRI studies in the study of language acquisition by measuring auditory comprehension and reading. The following paper is the first in a series concerning a unique longitudinal study devoted to the analysis of bi- and multilingual subjects who are: (1) already proficient in at least two languages; or (2) are acquiring Russian as a second/third language. The focus of the current analysis is to present data from the auditory sections of a set of three scans acquired from April, 2011 through April, 2012 on a five-person subject pool who are learning Russian during the study. All subjects were scanned using the same protocol for auditory comprehension on the same General Electric LX 3T Signa scanner in Duke University Hospital. Using a multivariate analysis of covariance (MANCOVA) for statistical analysis, proficiency measurements are shown to correlate significantly with scan results in the Russian conditions over time. The importance of both the left and right hemispheres in language processing is discussed. Special attention is devoted to the importance of contextualizing imaging data with corresponding behavioral and empirical testing data using a multivariate analysis of variance. This is the only study to date that includes: (1) longitudinal fMRI data with subject-based proficiency and behavioral data acquired in the same time frame; and (2) statistical modeling that demonstrates the importance of covariate language proficiency data for understanding imaging results of language acquisition. PMID:24961428

  16. Multilingualism and fMRI: Longitudinal Study of Second Language Acquisition

    Directory of Open Access Journals (Sweden)

    John Wright

    2013-05-01

    Full Text Available BOLD fMRI is often used for the study of human language. However, there are still very few attempts to conduct longitudinal fMRI studies in the study of language acquisition by measuring auditory comprehension and reading. The following paper is the first in a series concerning a unique longitudinal study devoted to the analysis of bi- and multilingual subjects who are: (1 already proficient in at least two languages; or (2 are acquiring Russian as a second/third language. The focus of the current analysis is to present data from the auditory sections of a set of three scans acquired from April, 2011 through April, 2012 on a five-person subject pool who are learning Russian during the study. All subjects were scanned using the same protocol for auditory comprehension on the same General Electric LX 3T Signa scanner in Duke University Hospital. Using a multivariate analysis of covariance (MANCOVA for statistical analysis, proficiency measurements are shown to correlate significantly with scan results in the Russian conditions over time. The importance of both the left and right hemispheres in language processing is discussed. Special attention is devoted to the importance of contextualizing imaging data with corresponding behavioral and empirical testing data using a multivariate analysis of variance. This is the only study to date that includes: (1 longitudinal fMRI data with subject-based proficiency and behavioral data acquired in the same time frame; and (2 statistical modeling that demonstrates the importance of covariate language proficiency data for understanding imaging results of language acquisition.

  17. Multilingualism and fMRI: Longitudinal Study of Second Language Acquisition.

    Science.gov (United States)

    Andrews, Edna; Frigau, Luca; Voyvodic-Casabo, Clara; Voyvodic, James; Wright, John

    2013-05-28

    BOLD fMRI is often used for the study of human language. However, there are still very few attempts to conduct longitudinal fMRI studies in the study of language acquisition by measuring auditory comprehension and reading. The following paper is the first in a series concerning a unique longitudinal study devoted to the analysis of bi- and multilingual subjects who are: (1) already proficient in at least two languages; or (2) are acquiring Russian as a second/third language. The focus of the current analysis is to present data from the auditory sections of a set of three scans acquired from April, 2011 through April, 2012 on a five-person subject pool who are learning Russian during the study. All subjects were scanned using the same protocol for auditory comprehension on the same General Electric LX 3T Signa scanner in Duke University Hospital. Using a multivariate analysis of covariance (MANCOVA) for statistical analysis, proficiency measurements are shown to correlate significantly with scan results in the Russian conditions over time. The importance of both the left and right hemispheres in language processing is discussed. Special attention is devoted to the importance of contextualizing imaging data with corresponding behavioral and empirical testing data using a multivariate analysis of variance. This is the only study to date that includes: (1) longitudinal fMRI data with subject-based proficiency and behavioral data acquired in the same time frame; and (2) statistical modeling that demonstrates the importance of covariate language proficiency data for understanding imaging results of language acquisition.

  18. Real-time MRI of the temporomandibular joint at 15 frames per second—A feasibility study

    International Nuclear Information System (INIS)

    Krohn, Sebastian; Gersdorff, Nikolaus; Wassmann, Torsten; Merboldt, Klaus-Dietmar; Joseph, Arun A.; Buergers, Ralf; Frahm, Jens

    2016-01-01

    The purpose of this study was to develop and evaluate a novel method for real-time MRI of TMJ function at high temporal resolution and with two different contrasts. Real-time MRI was based on undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion. Real-time MRI movies with T1 contrast were obtained with use of a radiofrequency-spoiled FLASH sequence, while movies with T2/T1 contrast employed a gradient-refocused FLASH version. TMJ function was characterized in 40 randomly selected volunteers by sequential 20 s acquisitions of both the right and left joint during voluntary opening and closing of the mouth (in a medial, central and lateral oblique sagittal section perpendicular to the long axis of the condylar head). All studies were performed on a commercial MRI system at 3 T using the standard head coil, while online reconstruction was achieved with a bypass computer fully integrated into the MRI system. As a first result, real-time MRI studies of the right and left TMJ were successfully performed in all 40 subjects (80 joints) within a total examination time per subject of only 15 min. Secondly, at an in-plane resolution of 0.75 mm and 5 mm section thickness, the achieved temporal resolution was 66.7 ms per image or 15 frames per second. Thirdly, both T1-weighted and T2/T1-weighted real-time MRI movies provided information about TMJ function such as disc position, condyle mobility and disc-condyle relationship. While T1 contrast offers a better delineation of structures during rapid jaw movements, T2/T1 contrast was rated superior for characterizing the articular disc. In conclusion, the proposed real-time MRI method may become a robust and efficient tool for the clinical assessment of TMJ function.

  19. Real-time MRI of the temporomandibular joint at 15 frames per second—A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Krohn, Sebastian; Gersdorff, Nikolaus; Wassmann, Torsten [Department of Prosthodontics, University Medical Center, Göttingen (Germany); Merboldt, Klaus-Dietmar [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany); Joseph, Arun A., E-mail: ajoseph@mpibpc.mpg.de [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany); Buergers, Ralf [Department of Prosthodontics, University Medical Center, Göttingen (Germany); Frahm, Jens [Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für Biophysikalische Chemie, Göttingen (Germany)

    2016-12-15

    The purpose of this study was to develop and evaluate a novel method for real-time MRI of TMJ function at high temporal resolution and with two different contrasts. Real-time MRI was based on undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion. Real-time MRI movies with T1 contrast were obtained with use of a radiofrequency-spoiled FLASH sequence, while movies with T2/T1 contrast employed a gradient-refocused FLASH version. TMJ function was characterized in 40 randomly selected volunteers by sequential 20 s acquisitions of both the right and left joint during voluntary opening and closing of the mouth (in a medial, central and lateral oblique sagittal section perpendicular to the long axis of the condylar head). All studies were performed on a commercial MRI system at 3 T using the standard head coil, while online reconstruction was achieved with a bypass computer fully integrated into the MRI system. As a first result, real-time MRI studies of the right and left TMJ were successfully performed in all 40 subjects (80 joints) within a total examination time per subject of only 15 min. Secondly, at an in-plane resolution of 0.75 mm and 5 mm section thickness, the achieved temporal resolution was 66.7 ms per image or 15 frames per second. Thirdly, both T1-weighted and T2/T1-weighted real-time MRI movies provided information about TMJ function such as disc position, condyle mobility and disc-condyle relationship. While T1 contrast offers a better delineation of structures during rapid jaw movements, T2/T1 contrast was rated superior for characterizing the articular disc. In conclusion, the proposed real-time MRI method may become a robust and efficient tool for the clinical assessment of TMJ function.

  20. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft