  1. An MRI system for imaging neonates in the NICU: initial feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Department of Radiology, Cincinnati, OH (United States); Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A. [Perinatal Institute, Cincinnati Children' s Hospital Medical Center, Division of Neonatology and Pulmonary Biology, Cincinnati, OH (United States); Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2012-11-15

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  2. An MRI system for imaging neonates in the NICU: initial feasibility study

    International Nuclear Information System (INIS)

    Tkach, Jean A.; Loew, Wolfgang; Pratt, Ron G.; Daniels, Barret R.; Giaquinto, Randy O.; Winter, Patrick M.; Li, Yu; Dumoulin, Charles L.; Hillman, Noah H.; Jobe, Alan H.; Kallapur, Suhas G.; Merhar, Stephanie L.; Ikegami, Machiko; Whitsett, Jeffrey A.; Kline-Fath, Beth M.

    2012-01-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate. (orig.)

  3. An MRI system for imaging neonates in the NICU: initial feasibility study.

    Science.gov (United States)

    Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L

    2012-11-01

    Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.

  4. A head-mounted display system for augmented reality: Initial evaluation for interventional MRI

    International Nuclear Information System (INIS)

    Wendt, M.; Wacker, F.K.

    2003-01-01

    Purpose: To discuss the technical details of a head mounted display with an augmented reality (AR) system and to describe a first pre-clinical evaluation in interventional MRI. Method: The AR system consists of a video-see-through head mounted display (HMD), mounted with a mini video camera for tracking and a stereo pair of mini cameras that capture live images of the scene. The live video view of the phantom/patient is augmented with graphical representations of anatomical structures from MRI image data and is displayed on the HMD. The application of the AR system with interventional MRI was tested using a MRI data set of the head and a head phantom. Results: The HMD enables the user to move around and observe the scene dynamically from various viewpoints. Within a short time the natural hand-eye coordination can easily be adapted to the slightly different view. The 3D perception is based on stereo and kinetic depth cues. A circular target with a diameter of 0.5 square centimeter was hit in 19 of 20 attempts. In a first evaluation the MRI image data augmented reality scene of a head phantom allowed good planning and precise simulation of a puncture. Conclusion: The HMD in combination with AR provides a direct, intuitive guidance for interventional MR procedures. (orig.) [de

  5. Respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK): Initial clinical experience on an MRI-guided radiotherapy system.

    Science.gov (United States)

    Han, Fei; Zhou, Ziwu; Du, Dongsu; Gao, Yu; Rashid, Shams; Cao, Minsong; Shaverdian, Narek; Hegde, John V; Steinberg, Michael; Lee, Percy; Raldow, Ann; Low, Daniel A; Sheng, Ke; Yang, Yingli; Hu, Peng

    2018-06-01

    To optimize and evaluate the respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK-4D-MRI) method in a 0.35 T MRI-guided radiotherapy (MRgRT) system. The study included seven patients with abdominal tumors treated on the MRgRT system. ROCK-4D-MRI and 2D-CINE, was performed immediately after one of the treatment fractions. Motion quantification based on 4D-MRI was compared with those based on 2D-CINE. The image quality of 4D-MRI was evaluated against 4D-CT. The gross tumor volumes (GTV) were defined based on individual respiratory phases of both 4D-MRI and 4D-CT and compared for their variability over the respiratory cycle. The motion measurements based on 4D-MRI matched well with 2D-CINE, with differences of 1.04 ± 0.52 mm in the superior-inferior and 0.54 ± 0.21 mm in the anterior-posterior directions. The image quality scores of 4D-MRI were significantly higher than 4D-CT, with better tumor contrast (3.29 ± 0.76 vs. 1.86 ± 0.90) and less motion artifacts (3.57 ± 0.53 vs. 2.29 ± 0.95). The GTVs were more consistent in 4D-MRI than in 4D-CT, with significantly smaller GTV variability (9.31 ± 4.58% vs. 34.27 ± 23.33%). Our study demonstrated the clinical feasibility of using the ROCK-4D-MRI to acquire high quality, respiratory motion-resolved 4D-MRI in a low-field MRgRT system. The 4D-MRI image could provide accurate dynamic information for radiotherapy treatment planning. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Qi, X; Yang, Y; Yang, L; Low, D; Sheng, K [UCLA, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomy changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for

  7. Superconductive MRI system, FLEXARTTM

    International Nuclear Information System (INIS)

    Suzuki, Hirokazu; Nishikawa, Mineki; Goro, Takehiko

    1994-01-01

    Since the establishment of TAMI (Toshiba America MRI Inc.) in 1989, it has been jointly working with Toshiba on developing a new infrastructure for computer and software technologies to be applied to new MRI (magnetic resonance imaging) systems. As a result of these efforts, the first product of a new series of MRI systems has been introduced on the market. Known as FLEXART TM (a newly created word combining FLEXible and ART), this MRI system incorporates a new 32-bit RISC computer and a new controller for pulse sequences and data acquisition. The product concepts of FLEXART TM are high image quality, high patient throughput, and ease of use, all of which are necessary features for an MRI system in the premium mid-field MRI market segment. (author)

  8. Predictive value of semi-quantitative MRI-based scoring systems for future knee replacement: data from the osteoarthritis initiative

    International Nuclear Information System (INIS)

    Hafezi-Nejad, Nima; Eng, John; Demehri, Shadpour; Zikria, Bashir; Carrino, John A.

    2015-01-01

    To evaluate, in a confirmatory fashion, whether baseline and change from baseline to 24-month follow-up in cartilage damage, bone marrow lesions and meniscal damage are predictors of knee replacement (KR) in subjects with a high risk of osteoarthritis (OA), independent of the level of physical activity, symptom severity and radiographic abnormalities. Data from the Osteoarthritis Initiative's (OAI) baseline and 24-month follow-up knee MRIs of 115 patients (age range: 45-78 years; 48 % female; BMI: 20.9-48.7) were analyzed. Cartilage, bone marrow and menisci were semi-quantitatively scored according to the Whole-Organ Magnetic Resonance Imaging Score (WORMS) and Boston-Leeds Osteoarthritis Knee Score (BLOKS) systems in all compartments. Baseline and 24-month interval changes in structural tissue damage assessed by BLOKS and WORMS were used as predictors of KR independent of clinical and radiographic parameters using Cox hazard analysis. Adjustments were performed for age, gender, BMI and physical activity (Physical Activity Scale for the Elderly: PASE), Western Ontario and McMaster Questionnaire (WOMAC) total score and radiographic Kellgren-Lawrence (KL) score. BLOKS and WORMS baseline cartilage scores were predictors of KR independent of the PASE, WOMAC and KL score. One score increase in the average baseline BLOKS full-thickness cartilage defect score was associated with a [hazard ratio (95 % CI)] 13.55 (3.61-50.89) times greater risk of KR independent of the PASE, WOMAC and KL score. Net reclassification improvements (NRIs) of the additional evaluation of 24-month follow-up MRI scores and assessment of changes were not significant for prediction of KR (NRI range: - 7.23 - 24.8 %). The BLOKS cartilage score for full-thickness cartilage defects had the highest hazard for KR. Follow-up MRI changes in structural tissue damage, detected by BLOKS and WORMS cartilage, bone marrow or meniscus scores (up to 24 months) had no significant predictive value in addition

  9. Predictive value of semi-quantitative MRI-based scoring systems for future knee replacement: data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hafezi-Nejad, Nima; Eng, John; Demehri, Shadpour [Johns Hopkins University School of Medicine, Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Zikria, Bashir [Johns Hopkins University, Department of Orthopedic Surgery, Baltimore, MD (United States); Carrino, John A. [Hospital for Special Surgery, Department of Radiology and Imaging, New York, NY (United States)

    2015-11-15

    To evaluate, in a confirmatory fashion, whether baseline and change from baseline to 24-month follow-up in cartilage damage, bone marrow lesions and meniscal damage are predictors of knee replacement (KR) in subjects with a high risk of osteoarthritis (OA), independent of the level of physical activity, symptom severity and radiographic abnormalities. Data from the Osteoarthritis Initiative's (OAI) baseline and 24-month follow-up knee MRIs of 115 patients (age range: 45-78 years; 48 % female; BMI: 20.9-48.7) were analyzed. Cartilage, bone marrow and menisci were semi-quantitatively scored according to the Whole-Organ Magnetic Resonance Imaging Score (WORMS) and Boston-Leeds Osteoarthritis Knee Score (BLOKS) systems in all compartments. Baseline and 24-month interval changes in structural tissue damage assessed by BLOKS and WORMS were used as predictors of KR independent of clinical and radiographic parameters using Cox hazard analysis. Adjustments were performed for age, gender, BMI and physical activity (Physical Activity Scale for the Elderly: PASE), Western Ontario and McMaster Questionnaire (WOMAC) total score and radiographic Kellgren-Lawrence (KL) score. BLOKS and WORMS baseline cartilage scores were predictors of KR independent of the PASE, WOMAC and KL score. One score increase in the average baseline BLOKS full-thickness cartilage defect score was associated with a [hazard ratio (95 % CI)] 13.55 (3.61-50.89) times greater risk of KR independent of the PASE, WOMAC and KL score. Net reclassification improvements (NRIs) of the additional evaluation of 24-month follow-up MRI scores and assessment of changes were not significant for prediction of KR (NRI range: - 7.23 - 24.8 %). The BLOKS cartilage score for full-thickness cartilage defects had the highest hazard for KR. Follow-up MRI changes in structural tissue damage, detected by BLOKS and WORMS cartilage, bone marrow or meniscus scores (up to 24 months) had no significant predictive value in addition

  10. VISARTTM superconducting MRI system

    International Nuclear Information System (INIS)

    Usui, Yoshiyuki; Goro, Takehiko; Yamagata, Hitoshi.

    1995-01-01

    We have developed VISART TM , a 1.5 T high-field magnetic resonance imaging (MRI) system based on technology developed for both the FLEXART TM (0.5T) and MRT-200/GP (1.5T) systems as the first and second products, respectively, of a new series of MRI systems. VISART TM is a newly coined word combining VISion and state-of-the-ART. A higher power gradient system and new high-speed imaging techniques have been developed to meet the market demand for higher resolution images and shorter scan times. The product concepts of VISART TM are high image quality, high patient throughput, flexible clinical application, and ease of use, all of which are essential features for an MRI system in the high-field MRI market segment. (author)

  11. PET/MRI in head and neck cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Platzek, Ivan; Laniado, Michael [Dresden University Hospital, Department of Radiology, Dresden (Germany); Beuthien-Baumann, Bettina [Dresden University Hospital, Department of Nuclear Medicine, Dresden (Germany); Schneider, Matthias [Dresden University Hospital, Oral and Maxillofacial Surgery, Dresden (Germany); Gudziol, Volker [Dresden University Hospital, Department of Otolaryngology, Dresden (Germany); Langner, Jens; Schramm, Georg; Hoff, Joerg van den [Institute of Bioinorganic and Radiopharmaceutical Chemistry, Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Kotzerke, Joerg [Dresden University Hospital, Nuclear Medicine, Dresden (Germany)

    2013-01-15

    To evaluate the feasibility of PET/MRI (positron emission tomography/magnetic resonance imaging) with FDG ({sup 18}F-fluorodeoxyglucose) for initial staging of head and neck cancer. The study group comprised 20 patients (16 men, 4 women) aged between 52 and 81 years (median 64 years) with histologically proven squamous cell carcinoma of the head and neck region. The patients underwent a PET scan on a conventional scanner and a subsequent PET/MRI examination on a whole-body hybrid system. FDG was administered intravenously prior to the conventional PET scan (267-395 MBq FDG, 348 MBq on average). The maximum standardized uptake values (SUV{sub max}) of the tumour and of both cerebellar hemispheres were determined for both PET datasets. The numbers of lymph nodes with increased FDG uptake were compared between the two PET datasets. No MRI-induced artefacts where observed in the PET images. The tumour was detected by PET/MRI in 17 of the 20 patients, by PET in 16 and by MRI in 14. The PET/MRI examination yielded significantly higher SUV{sub max} than the conventional PET scanner for both the tumour (p < 0.0001) and the cerebellum (p = 0.0009). The number of lymph nodes with increased FDG uptake detected using the PET dataset from the PET/MRI system was significantly higher the number detected by the stand-alone PET system (64 vs. 39, p = 0.001). The current study demonstrated that PET/MRI of the whole head and neck region is feasible with a whole-body PET/MRI system without impairment of PET or MR image quality. (orig.)

  12. Musculoskeletal MRI: dedicated systems

    International Nuclear Information System (INIS)

    Masciocchi, C.; Barile, A.; Satragno, L.

    2000-01-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  13. Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

    International Nuclear Information System (INIS)

    Afshar-Oromieh, A.; Haberkorn, U.; Schlemmer, H.P.; Fenchel, M.; Roethke, M.; Eder, M.; Eisenhut, M.; Hadaschik, B.A.; Kopp-Schneider, A.

    2014-01-01

    68 Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the 68 Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUV mean values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific 68 Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully. (orig.)

  14. Initial clinical experience with a quadrupole butterfly coil for spinal injection interventions in an open MRI system at 1.0 tesla.

    Science.gov (United States)

    Jonczyk, Martin; Hamm, Bernd; Heinrich, Andreas; Thomas, Andreas; Rathke, Hendrik; Schnackenburg, Bernhard; Güttler, Felix; Teichgräber, Ulf K M; de Bucourt, Maximilian

    2014-02-01

    To report our initial clinical experience with a new magnetic resonance imaging (MRI) quadrupole coil that allows interventions in prone position. Fifteen patients (seven women, eight men; average age, 42.8 years) were treated in the same 1.0-Tesla Panorama High Field Open (HFO) MRI system (Panorama HFO) using a quadrupole butterfly coil (Bfly) and compared with 15 patients matched for sex, age, and MR intervention using the MultiPurposeL coil (MPL), performed in conventional lateral decubitus position (all, Philips Medical Systems, Best, The Netherlands). All interventions were performed with a near-real-time proton density turbo spin echo (PD TSE) sequence (time to repeat/time to echo/flip angle/acquisition time, 600 ms/10 ms/90°/3 s/image). Qualitative and quantitative image analyses were performed, including signal intensity, signal-to-noise and contrast-to-noise ratio (SNR, CNR), contrast, and full width at half maximum (FWHM) measurements. Contrast differed significantly between the needle and muscles (Bfly 0.27/MPL 0.17), as well as the needle and periradicular fat (0.13/0.24) during the intervention (both, p=0.029), as well as the CNR between muscles and the needle (10.61/5.23; p=0.010), although the FWHM values did not (2.4/2.2; p=0.754). The signal intensity of the needle in interventional imaging (1152.9/793.2; p=0.006) and the postinterventional SNR values of subcutaneous fat (15.3/28.6; p=0.007), muscles (6.6/11.8; p=0.011), and the CNR between these tissues (8.7/17.5; p=0.004) yielded significant differences. The new coil is a valid alternative for MR-guided interventions in an open MRI system at 1.0 tesla, especially if patients cannot (or prefer not to) be in a lateral decubitus position or if prone positioning yields better access to the target zone.

  15. Value of repeat brain MRI in children with focal epilepsy and negative findings on initial MRI

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Tae Yeon; Kim, Ji Hye; Lee, Jee Hun; Yoo, So Young; Hwang, Sook Min; Lee, Mun Hyang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-08-01

    To evaluate the value of repeat brain magnetic resonance imaging (MRI) in identifying potential epileptogenic lesions in children with initial MRI-negative focal epilepsy. Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. During a 15-year period, 257 children (148 boys and 109 girls) with initial MRI-negative focal epilepsy were included. After re-evaluating both initial and repeat MRIs, positive results at repeat MRI were classified into potential epileptogenic lesions (malformation of cortical development and hippocampal sclerosis) and other abnormalities. Contributing factors for improved lesion conspicuity of the initially overlooked potential epileptogenic lesions were analyzed and classified into lesion factors and imaging factors. Repeat MRI was positive in 21% (55/257) and negative in 79% cases (202/257). Of the positive results, potential epileptogenic lesions comprised 49% (27/55) and other abnormalities comprised 11% of the cases (28/257). Potential epileptogenic lesions included focal cortical dysplasia (n = 11), hippocampal sclerosis (n = 10), polymicrogyria (n = 2), heterotopic gray matter (n = 2), microlissencephaly (n = 1), and cortical tumor (n = 1). Of these, seven patients underwent surgical resection. Contributing factors for new diagnoses were classified as imaging factors alone (n = 6), lesion factors alone (n = 2), both (n = 18), and neither (n = 1). Repeat MRI revealed positive results in 21% of the children with initial MRI-negative focal epilepsy, with 50% of the positive results considered as potential epileptogenic lesions. Enhanced MRI techniques or considering the chronological changes of lesions on MRI may improve the diagnostic yield for identification of potential epileptogenic lesions on repeat MRI.

  16. Value of repeat brain MRI in children with focal epilepsy and negative findings on initial MRI

    International Nuclear Information System (INIS)

    Jeon, Tae Yeon; Kim, Ji Hye; Lee, Jee Hun; Yoo, So Young; Hwang, Sook Min; Lee, Mun Hyang

    2017-01-01

    To evaluate the value of repeat brain magnetic resonance imaging (MRI) in identifying potential epileptogenic lesions in children with initial MRI-negative focal epilepsy. Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. During a 15-year period, 257 children (148 boys and 109 girls) with initial MRI-negative focal epilepsy were included. After re-evaluating both initial and repeat MRIs, positive results at repeat MRI were classified into potential epileptogenic lesions (malformation of cortical development and hippocampal sclerosis) and other abnormalities. Contributing factors for improved lesion conspicuity of the initially overlooked potential epileptogenic lesions were analyzed and classified into lesion factors and imaging factors. Repeat MRI was positive in 21% (55/257) and negative in 79% cases (202/257). Of the positive results, potential epileptogenic lesions comprised 49% (27/55) and other abnormalities comprised 11% of the cases (28/257). Potential epileptogenic lesions included focal cortical dysplasia (n = 11), hippocampal sclerosis (n = 10), polymicrogyria (n = 2), heterotopic gray matter (n = 2), microlissencephaly (n = 1), and cortical tumor (n = 1). Of these, seven patients underwent surgical resection. Contributing factors for new diagnoses were classified as imaging factors alone (n = 6), lesion factors alone (n = 2), both (n = 18), and neither (n = 1). Repeat MRI revealed positive results in 21% of the children with initial MRI-negative focal epilepsy, with 50% of the positive results considered as potential epileptogenic lesions. Enhanced MRI techniques or considering the chronological changes of lesions on MRI may improve the diagnostic yield for identification of potential epileptogenic lesions on repeat MRI

  17. Superconducting magnet systems for MRI

    International Nuclear Information System (INIS)

    Hawksworth, D.G.

    1988-01-01

    MRI is the first large scale commercial application of superconductivity and has not achieved the status of a mature industry with an annual turnover in the magnet industry alone in excess of $150M. Conservative estimates put the investment of the medical industry in MRI as a whole at more than a billion dollars. In the nine years since shipment of the first superconducting whole body imaging magnets of 0.3 Tesla field the standard product of the industry has become a system of 1 meter bore and field strength 0.5 Tesla to 1.5 Tesla. In this paper the evolution of present day MRI magnets from small bore but high field spectrometer magnets is reviewed and the direction of future developments discussed

  18. Primary Sjoegren's syndrome initially manifested by optic neuritis: MRI findings

    International Nuclear Information System (INIS)

    Kadota, Y.; Tokumaru, A.M.; Kohyama, S.; Okizuka, H.; Kaji, T.; Kusano, S.; Kamakura, K.

    2002-01-01

    We herein describe the MRI findings in a patient clinically diagnosed with primary Sjoegren's syndrome (SjS) initially manifested by retrobulbar optic neuritis. A 63-year-old woman suddenly had left ocular pain and progressive visual disturbance. MR T2-weighted images revealed hyperintensity in the left optic nerve, with swelling. Contrast-enhanced T1-weighted images showed no abnormal enhancement. Follow-up MRI 6 months after admission revealed no significant changes in the affected optic nerve. To our knowledge, optic neuritis as a complication of SjS has been reported in ten patients [1, 2, 3, 4, 5, 6] and MRI findings in only one of them [6]. We thought MR images were useful for visualizing optic nerve involvement in SjS and observing its course. (orig.)

  19. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  20. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  1. AC Initiation System.

    Science.gov (United States)

    An ac initiation system is described which uses three ac transmission signals interlocked for safety by frequency, phase, and power discrimination...The ac initiation system is pre-armed by the application of two ac signals have the proper phases, and activates a load when an ac power signal of the proper frequency and power level is applied. (Author)

  2. Initial performance evaluation of a preclinical PET scanner available as a clip-on assembly in a sequential PET/MRI system.

    Science.gov (United States)

    Vrigneaud, Jean-Marc; McGrath, John; Courteau, Alan; Pegg, Rosie; Sanchez-Pastor Gomis, Alberto; Camacho, Angela; Martin, Gary; Schramm, Nils; Brunotte, François

    2018-05-15

    We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of 8 detectors, each of which comprises a 12 × 12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29 × 29 (30 × 30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU-4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250-750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate (NECR) and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water- and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage. © 2018 Institute of Physics and Engineering in Medicine.

  3. Imaging of tumor viability in lung cancer. Initial results using 23Na-MRI

    International Nuclear Information System (INIS)

    Henzler, T.; Apfaltrer, P.; Haneder, S.; Schoenberg, S.O.; Fink, C.; Konstandin, S.; Schad, L.; Schmid-Bindert, G.; Manegold, C.; Wenz, F.

    2012-01-01

    23 Na-MRI has been proposed as a potential imaging biomarker for the assessment of tumor viability and the evaluation of therapy response but has not yet been evaluated in patients with lung cancer. We aimed to assess the feasibility of 23 Na-MRI in patients with lung cancer. Three patients with stage IV adenocarcinoma of the lung were examined on a clinical 3 Tesla MRI system (Magnetom TimTrio, Siemens Healthcare, Erlangen, Germany). Feasibility of 23 Na-MRI images was proven by comparison and fusion of 23 Na-MRI with 1 H-MR, CT and FDG-PET-CT images. 23 Na signal intensities (SI) of tumor and cerebrospinal fluid (CSF) of the spinal canal were measured and the SI ratio in tumor and CSF was calculated. One chemonaive patient was examined before and after the initiation of combination therapy (Carboplatin, Gemcitabin, Cetuximab). All 23 Na-MRI examinations were successfully completed and were of diagnostic quality. Fusion of 23 Na-MRI images with 1 H-MRI, CT and FDG-PET-CT was feasible in all patients and showed differences in solid and necrotic tumor areas. The mean tumor SI and the tumor/CSF SI ratio were 13.3 ± 1.8 x 103 and 0.83 ± 0.14, respectively. In necrotic tumors, as suggested by central non-FDG-avid areas, the mean tumor SI and the tumor/CSF ratio were 19.4 x 103 and 1.10, respectively. 23 Na-MRI is feasible in patients with lung cancer and could provide valuable functional molecular information regarding tumor viability, and potentially treatment response. (orig.)

  4. Central nervous system tuberculosis: MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kioumehr, F.; Dadsetan, M.R.; Rooholamini, S.A.; Au, A.

    1994-02-01

    The MRI findings of 18 proven cases of central nervous system (CNS) tuberculosis were reviewed; 10 patients were seropositive for HIV. All had medical, laboratory, or surgical proof of CNS tuberculosis. Eleven patients had meningitis, of whom two also had arachnoiditis. Five patients had focal intra-axial tuberculomas: four brain masses and one an intramedullary spinal lesion. Two patients had focal extra-axial tuberculomas: one in the pontine cistern, and one in the spine. In all 11 patients with meningitis MRI showed diffuse, thick, meningeal enhancement. All intraparenchymal tuberculomas showed low signal intensity on T2-weighted images and ring or nodular enhancement. The extra-axial tuberculomas had areas isointense or hypointense relative to normal brain and spinal cord on T2-weighted images. Although tuberculous meningitis cannot be differentiated from other meningitides on the basis of MR findings, intraparenchymal tuberculomas show characteristic T2 shortening, not found in most other space-occupying lesions. In the appropriate clinical setting, tuberculoma should be considered. (orig.)

  5. Comparison of PET/CT and PET/MRI hybrid systems using a {sup 68}Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, A. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Haberkorn, U. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Clinical Cooperation Unit of Nuclear Medicine, Heidelberg (Germany); Schlemmer, H.P.; Fenchel, M.; Roethke, M. [German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Eder, M.; Eisenhut, M. [German Cancer Research Center (DKFZ), Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Hadaschik, B.A. [University Hospital Heidelberg, Department of Urology, Heidelberg (Germany); Kopp-Schneider, A. [German Cancer Research Center (DKFZ), Department of Biostatistics, Heidelberg (Germany)

    2014-05-15

    {sup 68}Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the {sup 68}Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUV{sub mean} values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific {sup 68}Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully. (orig.)

  6. Initiation devices, initiation systems including initiation devices and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki; Wallace, Ronald S.

    2018-04-10

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materials include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.

  7. Superconducting MRI system, MRT-50A

    International Nuclear Information System (INIS)

    Sugimoto, Hiroshi; Asahina, Kiyotaka

    1987-01-01

    The writers' developmental work on MRI (magnetic resonance imaging) was started in 1983. The model used first was MRT-15A (0.15 T). The next model was MRT-22A (0.22 T) which had a magnetic self-shield. As for the development of superconducting MRI system, they started clinical evaluation at Toshiba Central Hospital MRI Center in 1984 and got the official approval in 1985. For the model, use was made of MRT-50A (0.5 T) employing a superconducting magnet made by Toshiba. Herein represented are the basis of the images obtained through MRT-50 and the fact that the application fields of MRI are going on increasing (not only to brain and spine areas but also to the areas of the chest, abdomen and joints), and also the results of the work-in-progress of application software. (author)

  8. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...... been attained that markedly increase the number and typology of systems with CEST properties. Currently much attention is also devoted to hyperpolarized molecules that display a sensitivity enhancement sufficient for their direct exploitation for the formation of the MR image. A real breakthrough...

  9. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    International Nuclear Information System (INIS)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J.; Mallucci, Connor L.; Pizer, Barry; Crooks, Daniel

    2012-01-01

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  10. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J. [Alder Hey Children' s NHS Foundation Trust, Department of Radiology, Liverpool (United Kingdom); Mallucci, Connor L. [Alder Hey Children' s Hospital, Department of Neurosurgery, Liverpool (United Kingdom); Pizer, Barry [Alder Hey Children' s Hospital, Department of Oncology, Liverpool (United Kingdom); Crooks, Daniel [Walton Centre for Neurology and Neurosurgery, Department of Pathology, Liverpool (United Kingdom)

    2012-02-15

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  11. Small animal simultaneous PET/MRI: initial experiences in a 9.4 T microMRI

    Energy Technology Data Exchange (ETDEWEB)

    Maramraju, Sri Harsha; Ravindranath, Bosky; Vaska, Paul; Schlyer, David J [Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY (United States); Smith, S David; Schulz, Daniela [Medical Department, Brookhaven National Laboratory, Upton, NY (United States); Junnarkar, Sachin S; Rescia, Sergio [Instrumentation Division, Brookhaven National Laboratory, Upton, NY (United States); Stoll, Sean; Purschke, Martin L; Woody, Craig L [Physics Department, Brookhaven National Laboratory, Upton, NY (United States); Southekal, Sudeepti [Brigham and Women' s Hospital, Boston, MA (United States); Pratte, Jean-Francois, E-mail: schlyer@bnl.gov [Universite de Sherbrooke, Sherbrooke, Quebec (Canada)

    2011-04-21

    We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

  12. High magnetic field MRI system

    International Nuclear Information System (INIS)

    Maeda, Hideaki; Urata, Masami; Satoh, Kozo

    1990-01-01

    A high field superconducting magnet, 4-5 T in central magnetic field, is required for magnetic resonance spectroscopic imaging (MRSI) on 31 P, essential nuclei for energy metabolism of human body. This paper reviews superconducting magnets for high field MRSI systems. Examples of the cross-sectional image and the spectrum of living animals are shown in the paper. (author)

  13. Initial Incidence of White Matter Hyperintensities on MRI in Astronauts

    Science.gov (United States)

    Norcross, Jason; Sherman, Paul; McGuire, Steve; Kochunov, Peter

    2016-01-01

    Introduction: Previous literature has described the increase in white matter hyperintensity (WMH) burden associated with hypobaric exposure in the U-2 and altitude chamber operating personnel. Although astronauts have similar hypobaric exposure pressures to the U2 pilot population, astronauts have far fewer exposures and each exposure would be associated with a much lower level of decompression stress due to rigorous countermeasures to prevent decompression sickness. Therefore, we postulated that the WMH burden in the astronaut population would be less than in U2 pilots. Methods: Twenty-one post-flight de-identified astronaut MRIs (5 mm slice thickness FLAIR sequences) were evaluated for WMH count and volume. The only additional data provided was an age range of the astronauts (43-57) and if they had ever performed an EVA (13 yes, 8 no). Results: WMH count in these 21 astronaut MRI was 21.0 +/- 24.8 (mean+/- SD) and volume was 0.382 +/- 0.602 ml, which was significantly higher than previously published results for the U2 pilots. No significant differences between EVA and no EVA groups existed. Age range of astronaut population is not directly comparable to the U2 population. Discussion: With significantly less frequent (sometimes none) and less stressful hypobaric exposures, yet a much higher incidence of increased WMH, this indicates the possibility of additional mechanisms beyond hypobaric exposure. This increase unlikely to be attributable just to the differences in age between astronauts and U2 pilots. Forward work includes continuing review of post-flight MRI and evaluation of pre to post flight MRI changes if available. Data mining for potential WMH risk factors includes collection of age, sex, spaceflight experience, EVA hours, other hypobaric exposures, hyperoxic exposures, radiation, high performance aircraft experience and past medical history. Finally, neurocognitive and vision/eye results will be evaluated for any evidence of impairment linked to

  14. Shimadzu superconductive MRI system, SMT-100

    International Nuclear Information System (INIS)

    Yamauchi, Mikio; Shimizu, Koji; Itoh, Masamichi; Fujio, Yasuo; Hashimoto, Yasushi

    1989-01-01

    The magnetic resonance imaging (MRI) system SMT-100 operating at 1.0 T (Tesla) developed lately is reported on this paper. SMT-100 is graded as higher class and more effective system in MR-imaging systems. Purpose of development are (1) supply of high quality imaging, (2) high patient throughput, and (3) low operating cost. Following developments are carried out in this system: (1) development of 1.0 T superconducting magnet without liquid nitrogen vessel, attached self-magnetic shield, (2) development of digital controller system for being able to correspond to future pulse sequences, (3) development of flexible coil and establishment of displacement scanning method by fitting the coil on examination position, (4) separate console system (viewing console and scanning console) for high patient throughput. The outline of SMT-100 and clinical data by the system are reported here. (author)

  15. MRI changes in the central nervous system in a child with lupus erythematosus

    International Nuclear Information System (INIS)

    Gieron, M.A.; Khoromi, S.; Campos, A.

    1995-01-01

    We report on a 10-year-old girl with systemic lupus erythematosus who presented in status epilepticus as the only manifestation of central nervous system involvement. MRI of the brain showed diffuse gray and white matter lesions which almost completely resolved after treatment with methylprednisolone. MRI findings in this child are similar to those in adults with diffuse clinical manifestations. The study is essential in the initial evaluation of patients suspected of central nervous system lupus. (orig.)

  16. MRI changes in the central nervous system in a child with lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Gieron, M A [Dept. of Pediatrics, Univ. of South Florida, Coll. of Medicine, Tampa, FL (United States); Khoromi, S [Dept. of Neurology, Univ. of South Florida, Coll. of Medicine, Tampa, FL (United States); Campos, A [Dept. of Pediatrics, Univ. of South Florida, Coll. of Medicine, Tampa, FL (United States)

    1995-05-01

    We report on a 10-year-old girl with systemic lupus erythematosus who presented in status epilepticus as the only manifestation of central nervous system involvement. MRI of the brain showed diffuse gray and white matter lesions which almost completely resolved after treatment with methylprednisolone. MRI findings in this child are similar to those in adults with diffuse clinical manifestations. The study is essential in the initial evaluation of patients suspected of central nervous system lupus. (orig.)

  17. Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system.

    Science.gov (United States)

    Al-Wakeel, Nadya; O h-Ici, Darach; Schmitt, Katharina R; Messroghli, Daniel R; Riesenkampff, Eugénie; Berger, Felix; Kuehne, Titus; Peters, Bjoern

    2016-02-01

    In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems. Material and methods CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale. A total of nine patients with CHD (mean age 34.0 years, range 19.5-53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients. Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.

  18. Update on the MRI Core of the Alzheimer's Disease Neuroimaging Initiative

    Science.gov (United States)

    Jack, Clifford R; Bernstein, Matt A; Borowski, Bret J; Gunter, Jeffrey L; Fox, Nick C; Thompson, Paul M; Schuff, Norbert; Krueger, Gunnar; Killiany, Ronald J; DeCarli, Charles S; Dale, Anders M; Weiner, Michael W

    2010-01-01

    Functions of the ADNI MRI core fall into three categories: (1) those of the central MRI core lab at Mayo Clinic, Rochester, Minnesota, needed to generate high quality MRI data in all subjects at each time point; (2) those of the funded ADNI MRI core imaging analysis groups responsible for analyzing the MRI data, and (3) the joint function of the entire MRI core in designing and problem solving MR image acquisition, pre-processing and analyses methods. The primary objective of ADNI was and continues to be improving methods for clinical trials in Alzheimer's disease. Our approach to the present (“ADNI-GO”) and future (“ADNI-2”, if funded) MRI protocol will be to maintain MRI methodological consistency in previously enrolled “ADNI-1” subjects who are followed longitudinally in ADNI-GO and ADNI-2. We will modernize and expand the MRI protocol for all newly enrolled ADNI-GO and ADNI-2 subjects. All newly enrolled subjects will be scanned at 3T with a core set of three sequence types: 3D T1-weighted volume, FLAIR, and a long TE gradient echo volumetric acquisition for micro hemorrhage detection. In addition to this core ADNI-GO and ADNI-2 protocol, we will perform vendor specific pilot sub-studies of arterial spin labeling perfusion, resting state functional connectivity and diffusion tensor imaging. One each of these sequences will be added to the core protocol on systems from each MRI vendor. These experimental sub-studies are designed to demonstrate the feasibility of acquiring useful data in a multi-center (but single vendor) setting for these three emerging MRI applications. PMID:20451869

  19. Clinical validation of synthetic brain MRI in children: initial experience

    International Nuclear Information System (INIS)

    West, Hollie; Leach, James L.; Jones, Blaise V.; Care, Marguerite; Radhakrishnan, Rupa; Merrow, Arnold C.; Alvarado, Enrique; Serai, Suraj D.

    2017-01-01

    The purpose of this study was to determine the diagnostic accuracy of synthetic MR sequences generated through post-acquisition processing of a single sequence measuring inherent R1, R2, and PD tissue properties compared with sequences acquired conventionally as part of a routine clinical pediatric brain MR exam. Thirty-two patients underwent routine clinical brain MRI with conventional and synthetic sequences acquired (22 abnormal). Synthetic axial T1, T2, and T2 fluid attenuation inversion recovery or proton density-weighted sequences were made to match the comparable clinical sequences. Two exams for each patient were de-identified. Four blinded reviewers reviewed eight patients and were asked to generate clinical reports on each exam (synthetic or conventional) at two different time points separated by a mean of 33 days. Exams were rated for overall and specific finding agreement (synthetic/conventional and compared to gold standard consensus review by two senior reviewers with knowledge of clinical report), quality, and diagnostic confidence. Overall agreement between conventional and synthetic exams was 97%. Agreement with consensus readings was 84% (conventional) and 81% (synthetic), p = 0.61. There were no significant differences in sensitivity, specificity, or accuracy for specific imaging findings involving the ventricles, CSF, brain parenchyma, or vasculature between synthetic or conventional exams (p > 0.05). No significant difference in exam quality, diagnostic confidence, or noise/artifacts was noted comparing studies with synthetic or conventional sequences. Diagnostic accuracy and quality of synthetically generated sequences are comparable to conventionally acquired sequences as part of a standard pediatric brain exam. Further confirmation in a larger study is warranted. (orig.)

  20. Clinical validation of synthetic brain MRI in children: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    West, Hollie; Leach, James L.; Jones, Blaise V.; Care, Marguerite; Radhakrishnan, Rupa; Merrow, Arnold C.; Alvarado, Enrique; Serai, Suraj D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2017-01-15

    The purpose of this study was to determine the diagnostic accuracy of synthetic MR sequences generated through post-acquisition processing of a single sequence measuring inherent R1, R2, and PD tissue properties compared with sequences acquired conventionally as part of a routine clinical pediatric brain MR exam. Thirty-two patients underwent routine clinical brain MRI with conventional and synthetic sequences acquired (22 abnormal). Synthetic axial T1, T2, and T2 fluid attenuation inversion recovery or proton density-weighted sequences were made to match the comparable clinical sequences. Two exams for each patient were de-identified. Four blinded reviewers reviewed eight patients and were asked to generate clinical reports on each exam (synthetic or conventional) at two different time points separated by a mean of 33 days. Exams were rated for overall and specific finding agreement (synthetic/conventional and compared to gold standard consensus review by two senior reviewers with knowledge of clinical report), quality, and diagnostic confidence. Overall agreement between conventional and synthetic exams was 97%. Agreement with consensus readings was 84% (conventional) and 81% (synthetic), p = 0.61. There were no significant differences in sensitivity, specificity, or accuracy for specific imaging findings involving the ventricles, CSF, brain parenchyma, or vasculature between synthetic or conventional exams (p > 0.05). No significant difference in exam quality, diagnostic confidence, or noise/artifacts was noted comparing studies with synthetic or conventional sequences. Diagnostic accuracy and quality of synthetically generated sequences are comparable to conventionally acquired sequences as part of a standard pediatric brain exam. Further confirmation in a larger study is warranted. (orig.)

  1. Initial observations of electronic medical record usage during CT and MRI interpretation: Frequency of use and impact on workflow.

    Science.gov (United States)

    Lin, Abraham; Harris, Mitchell; Zalis, Michael

    2010-07-01

    Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.

  2. Light-initiated detonation systems

    Science.gov (United States)

    Cooper, Stafford S.; Malone, Philip G.; Bartholomew, Stephen W.; Necker, William J.

    1986-09-01

    Numerous light sources could be employed in detonation systems, but lasers have the most efficient coupling to optical fibers and can generate energetic light pulses required for detonation. Flash lamp-pumped, solid state lasers are presently the most useful light source for explosive initiation. Laser diodes in current production cannot generate enough energy for practical applications. The most useful optical fiber for blast line application is a step index fiber with a large core-to-cladding ratio. The large core minimizes energy losses due to misalignment core of fibers in connectors. Couplers that involve mechanically crimped connectors and cleaved fibers, rather than the epoxy-cemented connectors with polished fibers, provide superior energy transmission due to the reduced carbonization at the fiber end. Detonators for optical initiation systems are similar in basic construction to those employed in electrical initiation systems. Explosive and pyrotechnic charges can also be similar. Either primary or secondary explosives can be initiated in present laser-based systems. Two laser detonation systems are presently accessible; a multiple-shot laser with a single-shot, single fiber system designed for use with detonators containing primary explosives. Additional research related to development of low-energy, photoreactive detonators, continuity checking techniques and improved connectors and fibers can produce significant improvements in presently fielded systems.

  3. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  4. Automatic initialization and quality control of large-scale cardiac MRI segmentations.

    Science.gov (United States)

    Albà, Xènia; Lekadir, Karim; Pereañez, Marco; Medrano-Gracia, Pau; Young, Alistair A; Frangi, Alejandro F

    2018-01-01

    Continuous advances in imaging technologies enable ever more comprehensive phenotyping of human anatomy and physiology. Concomitant reduction of imaging costs has resulted in widespread use of imaging in large clinical trials and population imaging studies. Magnetic Resonance Imaging (MRI), in particular, offers one-stop-shop multidimensional biomarkers of cardiovascular physiology and pathology. A wide range of analysis methods offer sophisticated cardiac image assessment and quantification for clinical and research studies. However, most methods have only been evaluated on relatively small databases often not accessible for open and fair benchmarking. Consequently, published performance indices are not directly comparable across studies and their translation and scalability to large clinical trials or population imaging cohorts is uncertain. Most existing techniques still rely on considerable manual intervention for the initialization and quality control of the segmentation process, becoming prohibitive when dealing with thousands of images. The contributions of this paper are three-fold. First, we propose a fully automatic method for initializing cardiac MRI segmentation, by using image features and random forests regression to predict an initial position of the heart and key anatomical landmarks in an MRI volume. In processing a full imaging database, the technique predicts the optimal corrective displacements and positions in relation to the initial rough intersections of the long and short axis images. Second, we introduce for the first time a quality control measure capable of identifying incorrect cardiac segmentations with no visual assessment. The method uses statistical, pattern and fractal descriptors in a random forest classifier to detect failures to be corrected or removed from subsequent statistical analysis. Finally, we validate these new techniques within a full pipeline for cardiac segmentation applicable to large-scale cardiac MRI databases. The

  5. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    Energy Technology Data Exchange (ETDEWEB)

    Itatani, R., E-mail: banguliao@gmail.com [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Namimoto, T. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan); Atsuji, S.; Katahira, K.; Morishita, S. [Department of Radiology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitani, K.; Hamada, Y. [Department of Urology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Kitaoka, M. [Department of Pathology, Kumamoto Chuo Hospital, 1-5-1, Tainoshima, Kumamoto 862-0965 (Japan); Nakaura, T. [Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046 (Japan); Yamashita, Y. [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Kumamoto 860-8556 (Japan)

    2014-10-15

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy.

  6. Negative predictive value of multiparametric MRI for prostate cancer detection: Outcome of 5-year follow-up in men with negative findings on initial MRI studies

    International Nuclear Information System (INIS)

    Itatani, R.; Namimoto, T.; Atsuji, S.; Katahira, K.; Morishita, S.; Kitani, K.; Hamada, Y.; Kitaoka, M.; Nakaura, T.; Yamashita, Y.

    2014-01-01

    Highlights: • We assess the negative predictive value of multiparametric MRI for prostate cancer. • Patients with positive prostate biopsy findings were defined as false-negative. • Patients with negative initial prostate biopsy findings were followed up for 5 years. • The negative predictive value was 89.6% for significant prostate cancer. • MRI is a useful tool to rule out significant prostate cancer before biopsy. - Abstract: Objective: To assess the clinical negative predictive value (NPV) of multiparametric MRI (mp-MRI) for prostate cancer in a 5-year follow-up. Materials and methods: One hundred ninety-three men suspected of harboring prostate cancer with negative MRI findings were included. Patients with positive transrectal ultrasound (TRUS)-guided biopsy findings were defined as false-negative. Patients with negative initial TRUS-guided biopsy findings were followed up and only patients with negative findings by digital rectal examination, MRI, and repeat biopsy and no increase in PSA at 5-year follow-up were defined as “clinically negative”. The clinical NPV of mp-MRI was calculated. For quantitative analysis, mean signal intensity on T2-weighted images and the mean apparent diffusion coefficient value on ADC maps of the initial MRI studies were compared between peripheral-zone (PZ) cancer and the normal PZ based on pathologic maps of patients who had undergone radical prostatectomy. Results: The clinical NPV of mp-MRI was 89.6% for significant prostate cancer. Small cancers, prostatitis, and benign prostatic hypertrophy masking prostate cancer returned false-negative results. Quantitative analysis showed that there was no significant difference between PZ cancer and the normal PZ. Conclusion: The mp-MRI revealed a high clinical NPV and is a useful tool to rule out clinically significant prostate cancer before biopsy

  7. Superconductive MRI system, MRT-50A/SUPER

    International Nuclear Information System (INIS)

    Suzuki, Hirokazu; Goro, Takehiko

    1992-01-01

    The MRI (magnetic resonance imaging) market has been rapidly growing and more than 1,300 MRI systems are now operating in the Japanese domestic market. An upper-middle range MRI market, which is characterized by high-image quality, has newly appeared between the high-end and middle-range market niches since last year. To be competitive in this upper-middle range market, Toshiba has developed a superconductive MRI system, the MRT-50A/SUPER. The new system featured a high-performance actively shielded gradient coil called the TSGC (twin-shielded gradient coil), installed in a compact superconductive magnet. This paper introduces the MRT-50A/SUPER and describes recent developments in MRI technology. (author)

  8. Neurodegenerative diseases of the central motor system in MRI

    International Nuclear Information System (INIS)

    Alfke, K.

    2005-01-01

    Neurodegenerative diseases of the central motor system often lead to discrete but functionally important parenchymal abnormalities in various parts of the brain. MRI is the most sensitive imaging method to detect these abnormalities. Various neurodegenerative diseases are presented with their clinical symptoms and MRI findings. Criteria for differential diagnosis are provided as well. (orig.)

  9. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hye Young [Department of Radiology, Gyeongsang National University Hospital, Jinju 660-702 (Korea, Republic of); Kim, Sun Mi; Jang, Mijung; Yun, Bo La [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Kim, Sung-Won; Kang, Eunyoung [Department of Surgery, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Park, So Yeon [Department of Pathology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Ko, Eun Sook [Department of Radiology, Samsung Medical Center, Seoul 135-710 (Korea, Republic of)

    2013-07-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions.

  10. MRI-Guided Intervention for Breast Lesions Using the Freehand Technique in a 3.0-T Closed-Bore MRI Scanner: Feasibility and Initial Results

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Sun Mi; Jang, Mijung; Yun, Bo La; Kim, Sung-Won; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Ko, Eun Sook

    2013-01-01

    To report the feasibility of magnetic resonance imaging (MRI)-guided intervention for diagnosing suspicious breast lesions detectable by MRI only, using the freehand technique with a 3.0-T closed-bore MRI scanner. Five women with 5 consecutive MRI-only breast lesions underwent MRI-guided intervention: 3 underwent MRI-guided needle localization and 2, MRI-guided vacuum-assisted biopsy. The interventions were performed in a 3.0-T closed-bore MRI system using a dedicated phased-array breast coil with the patients in the prone position; the freehand technique was used. Technical success and histopathologic outcome were analyzed. MRI showed that four lesions were masses (mean size, 11.5 mm; range, 7-18 mm); and 1, a nonmass-like enhancement (maximum diameter, 21 mm). The locations of the lesions with respect to the breast with index cancer were as follows: different quadrant, same breast - 3 cases; same quadrant, same breast - 1 case; and contralateral breast - 1 case. Histopathologic evaluation of the lesions treated with needle localization disclosed perilobular hemangioma, fibrocystic change, and fibroadenomatous change. The lesions treated with vacuum-assisted biopsy demonstrated a radial scar and atypical apocrine hyperplasia. Follow-up MRI after 2-7 months (mean, 4.6 months) confirmed complete lesion removal in all cases. MRI-guided intervention for breast lesions using the freehand technique with a 3.0-T closed-bore MRI scanner is feasible and accurate for diagnosing MRI-only lesions

  11. Blasting agents and initiation systems

    Energy Technology Data Exchange (ETDEWEB)

    Fiscor, S.

    2000-01-01

    Although blasting differs between and within each industry, as a whole, the mines and quarries are making a shift from a purely ammonium nitrate/fuel oil (ANFO) mixture to a blend of emulsion and ANFO on a straight emulsion. Non-electric (shock tube) initiation systems have provided a viable alternative to the electric detonator (blasting cap). Explosives manufacturers are seeing their roles changes to being blasting contractors or consultants rather than just suppliers. The article discusses these trends and gives examples of typical blasting techniques and amounts of blasting agent used at large USA surface coal mines. Electric caps are still used in blasting underground coal. The Ensign Bickford Co. (EBCo) is developing electronic detonators and has been field testing an electronic initiator, the DIGIDET detonator, for the last four years. When commercially available, electronic detonators will be accurate but will come with a hefty price tag. 2 photos.

  12. Positron emission tomography/magnetic resonance imaging (PET/MRI: An update and initial experience at HC-FMUSP

    Directory of Open Access Journals (Sweden)

    Marcelo A. Queiroz

    Full Text Available Summary The new technology of PET/MRI is a prototype of hybrid imaging, allowing for the combination of molecular data from PET scanning and morphofunctional information derived from MRI scanning. Recent advances regarding the technical aspects of this device, especially after the development of MRI-compatible silicon photomultipliers of PET, permitted an increase in the diagnostic performance of PET/MRI translated into dose reduction and higher imaging quality. Among several clinical applications, PET/MRI gains ground initially in oncology, where MRI per se plays an essential role in the assessment of primary tumors (which is limited in the case of PET/CT, including prostate, rectal and gynecological tumors. On the other hand, the evaluation of the lungs remains an enigma although new MRI sequences are being designed to overcome this. More clinical indications of PET/MRI are seen in the fields of neurology, cardiology and inflammatory processes, and the use of PET/MRI also opens perspectives for pediatric populations as it involves very low radiation exposure. Our review aimed to highlight the current indications of PET/MRI and discuss the challenges and perspectives of PET/MRI at HC-FMUSP.

  13. Abnormal muscle MRI in a patient with systemic juvenile arthritis

    International Nuclear Information System (INIS)

    Miller, M.L.; Levinson, L.; Pachman, L.M.; Poznanski, A.

    1995-01-01

    Although myositis has been described in children with systemic-onset juvenile arthritis (JA), its documentation by MRI has not been reported. We describe a 13-year-old boy with systemic-onset JA, severe myalgia, and elevated muscle enzymes, but normal muscle strength, who had an MRI consistent with myositis. Magnetic resonance imaging can identify the specific location of myositis, allowing more precise definition of a potential complication of systemic JA. (orig.)

  14. Abnormal muscle MRI in a patient with systemic juvenile arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M.L. [Dept. of Pediatrics, Northwestern Univ. Medical School, Chicago, IL (United States); Levinson, L. [Dept. of Pediatrics, Northwestern Univ. Medical School, Chicago, IL (United States); Pachman, L.M. [Dept. of Pediatrics, Northwestern Univ. Medical School, Chicago, IL (United States); Poznanski, A. [Dept. of Radiology, Northwestern Univ. Medical School, Chicago, IL (United States)

    1995-11-01

    Although myositis has been described in children with systemic-onset juvenile arthritis (JA), its documentation by MRI has not been reported. We describe a 13-year-old boy with systemic-onset JA, severe myalgia, and elevated muscle enzymes, but normal muscle strength, who had an MRI consistent with myositis. Magnetic resonance imaging can identify the specific location of myositis, allowing more precise definition of a potential complication of systemic JA. (orig.)

  15. Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Hatazawa, Jun; Aoki, Masaaki; Sugiyama, Eiji; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku

    2011-01-01

    The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.

  16. MRI

    Science.gov (United States)

    ... the room. Pins, hairpins, metal zippers, and similar metallic items can distort the images. Removable dental work ... an MRI can cause heart pacemakers and other implants not to work as well. The magnets can ...

  17. Initial experience in hybrid PET-MRI for evaluation of refractory focal onset epilepsy.

    Science.gov (United States)

    Shin, Hae W; Jewells, Valerie; Sheikh, Arif; Zhang, Jingwen; Zhu, Hongtu; An, Hongyu; Gao, Wei; Shen, Dinggang; Hadar, Eldad; Lin, Weili

    2015-09-01

    We aim to evaluate the utility/improved accuracy of hybrid PET/MR compared to current practice separate 3T MRI and PET-CT imaging for localization of seizure foci. In a pilot study, twenty-nine patients undergoing epilepsy surgery evaluation were imaged using PET/MR. This subject group had 29 previous clinical 3T MRI as well as 12 PET-CT studies. Prior clinical PET and MR images were read sequentially while the hybrid PET/MR was concurrently read. The median interval between hybrid PET/MR and prior imaging studies was 5 months (range 1-77 months). In 24 patients, there was no change in the read between the clinical exams and hybrid PET/MR while new anatomical or functional lesions were identified by hybrid PET/MR in 5 patients without significant clinical change. Four new anatomical MR lesions were seen with concordant PET findings. The remaining patient revealed a new abnormal PET lesion without an MR abnormality. All new PET/MR lesions were clinically significant with concordant EEG and/or SPECT results as potential epileptic foci. Our initial hybrid PET-MRI experience increased diagnostic yields for detection of potential epileptic lesions. This may be due to the unique advantage of improved co-registration and simultaneous review of both structural and functional data. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  18. The OMERACT rheumatoid arthritis magnetic resonance imaging (MRI) scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, Charles G.; Bird, Paul

    2017-01-01

    Objective: The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying...... inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. Methods: MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working...... Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Results: Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables...

  19. Development of a new compact intraoperative magnetic resonance imaging system: concept and initial experience.

    Science.gov (United States)

    Morita, Akio; Sameshima, Tetsuro; Sora, Shigeo; Kimura, Toshikazu; Nishimura, Kengo; Itoh, Hirotaka; Shibahashi, Keita; Shono, Naoyuki; Machida, Toru; Hara, Naoko; Mikami, Nozomi; Harihara, Yasushi; Kawate, Ryoichi; Ochiai, Chikayuki; Wang, Weimin; Oguro, Toshiki

    2014-06-01

    Magnetic resonance imaging (MRI) during surgery has been shown to improve surgical outcomes, but the current intraoperative MRI systems are too large to install in standard operating suites. Although 1 compact system is available, its imaging quality is not ideal. We developed a new compact intraoperative MRI system and evaluated its use for safety and efficacy. This new system has a magnetic gantry: a permanent magnet of 0.23 T and an interpolar distance of 32 cm. The gantry system weighs 2.8 tons and the 5-G line is within the circle of 2.6 m. We created a new field-of-view head coil and a canopy-style radiofrequency shield for this system. A clinical trial was initiated, and the system has been used in 44 patients. This system is significantly smaller than previous intraoperative MRI systems. High-quality T2 images could discriminate tumor from normal brain tissue and identify anatomic landmarks for accurate surgery. The average imaging time was 45.5 minutes, and no clinical complications or MRI system failures occurred. Floating organisms or particles were minimal (1/200 L maximum). This intraoperative, compact, low-magnetic-field MRI system can be installed in standard operating suites to provide relatively high-quality images without sacrificing safety. We believe that such a system facilitates the introduction of the intraoperative MRI.

  20. 19F-MRI of stomach and intestine using 50% FTPA emulsion under 2T MRI system

    International Nuclear Information System (INIS)

    Shimizu, Masahiro; Kobayashi, Teturou; Mishima, Hideyuki

    1991-01-01

    1 H-MRI is of clinical value in many lesions, but imaging of gastrointestinal lesions is still difficult by 1 H-MRI. To overcome this weak point of 1 H-MRI, rabbit stomachs were examined by 19 F-MRI using 50% FTPA emulsion. We also examined the stability of 50% FTPA emulsion in the stomach and its absorption from the gastrointestinal tract. We found that 50% FTPA emulsion was very stable at pH 1.5, and only a very small amount was absorbed. A rabbit (weighing 2 kg) was anesthetized, and 100 ml of 50% FTPA emulsion was infused into the stomach by catheter. 19 F-MRI was performed in this rabbit using a 2 T superconducting MRI system designed for human use, and clear pictures of the stomach were obtained. From our results we conclude that 19 F-MRI of the stomach using 50% FTPA emulsion is of practical value. (author)

  1. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size.

    Science.gov (United States)

    Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.

  2. [Microinjection Monitoring System Design Applied to MRI Scanning].

    Science.gov (United States)

    Xu, Yongfeng

    2017-09-30

    A microinjection monitoring system applied to the MRI scanning was introduced. The micro camera probe was used to stretch into the main magnet for real-time video injection monitoring of injection tube terminal. The programming based on LabVIEW was created to analysis and process the real-time video information. The feedback signal was used for intelligent controlling of the modified injection pump. The real-time monitoring system can make the best use of injection under the condition that the injection device was away from the sample which inside the magnetic room and unvisible. 9.4 T MRI scanning experiment showed that the system in ultra-high field can work stability and doesn't affect the MRI scans.

  3. A new MRI grading system for chondromalacia patellae.

    Science.gov (United States)

    Özgen, Ali; Taşdelen, Neslihan; Fırat, Zeynep

    2017-04-01

    Background Chondromalacia patellae is a very common disorder. Although magnetic resonance imaging (MRI) is widely used to investigate patellar cartilage lesions, there is no descriptive MRI-based grading system for chondromalacia patellae. Purpose To propose a new MRI grading system for chondromalacia patellae with corresponding high resolution images which might be useful in precisely reporting and comparing knee examinations in routine daily practice and used in predicting natural course and clinical outcome of the patellar cartilage lesions. Material and Methods High resolution fat-saturated proton density (FS PD) images in the axial plane with corresponding T2 mapping images were reviewed. A detailed MRI grading system covering the deficiencies of the existing gradings has been set and presented on these images. Two experienced observers blinded to clinical data examined 44 knee MR images and evaluated patellar cartilage changes according to the proposed grading system. Inter- and intra-rater validity testing using kappa statistics were calculated. Results A descriptive and detailed grading system with corresponding FS PD and T2 mapping images has been presented. Inter-rater agreement was 0.80 (95% confidence interval [CI], 0.71-0.89). Intra-rater agreements were 0.83 (95% CI, 0.74-0.91) for observer A and 0.79 (95% CI, 0.70-0.88) for observer B (k-values). Conclusion We present a new MRI grading system for chondromalacia patellae with corresponding images and good inter- and intra-rater agreement which might be useful in reporting and comparing knee MRI examinations in daily practice and may also have the potential for using more precisely predicting prognosis and clinical outcome of the patients.

  4. Initiation disruptor systems and methods of initiation disruption

    Science.gov (United States)

    Baum, Dennis W

    2014-09-23

    A system that may be used as an initiation disruption system (IDS) according to one embodiment includes an explosive charge; a plurality of particles in a layer at least partially surrounding the explosive charge; and a fire suppressant adjacent the plurality of particles. A method for disabling an object according to one embodiment includes placing the system as recited above near an object; and causing the explosive charge to initiate, thereby applying mechanical loading to the object such that the object becomes disabled. Additional systems and methods are also presented. A device according to another embodiment includes a plurality of particles bound by a binder thereby defining a sidewall having an interior for receiving an explosive; and a fire suppressant adjacent the plurality of particles and binder. Additional systems and methods are also presented.

  5. Implementation of a ferromagnetic detection system in a clinical MRI setting

    International Nuclear Information System (INIS)

    Orchard, L.J.

    2015-01-01

    Purpose: To evaluate the implementation of a ferromagnetic detection system (FMDS) into a clinical MRI setting. Materials and methods: One thousand patients were considered for MRI safety screening using an FMDS. Equipment used was a Ferroguard ® Screener (Metrasens Ltd, Malvern, Worcestershire, UK). Fully gowned patients rotated 360° in front of the FMDS in a standardized manner following traditional MRI screening methods (the use of a written questionnaire (Fig. B.1) and verbal interview. Results: Final results included 1032 individual screening events performed in 977 patients. There were 922 (94%) initial passes using the FMDS; 34 (4%) failed initial screens but passed a subsequent screen; 21 (2%) failed the initial and subsequent screens. Thus, including all screening events (n = 1032), there were 956 (93%) true negatives (TN); 21 (2%) false positives (FP) and 55 (5%) true positives (TP). No false negatives (FN) were recorded. Therefore, sensitivity was 100% and specificity was 98%. Conclusion: Implementation and correct usage of an FMDS proved to increase safety within a clinical MRI environment by alerting staff to ferromagnetic items or implants not identified using traditional MRI screening methods. An FMDS should be used as an adjunct to these methods. The information in this study pertains to the specific equipment used in this investigation. - Highlights: • Ferromagnetic detection system sensitivity in this study was 100%. • Ferromagnetic detection system specificity in this study was 98%. • The additional screening procedure had little impact on throughput ie additional time taken was minimal. • Staff training, technique and compliance is important in implementing the screening procedures. • The ferromagnetic detection system identified objects that may have demonstrated projectile, heating or artefact effects

  6. Clinical application of MRI to fetal central nervous system

    International Nuclear Information System (INIS)

    Wang Guangbing; Chen Liguang; Ma Yuxiang; Liu Wen; Lin Xiangtao; Shi Hao; Yang Zhenzhen; Qu Jun

    2005-01-01

    Objective: To explore the value of MRI on fetal central nervous system. Methods: Twenty-four women with complicated pregnancies, aged from 22 to 32 years (average 27 years) and with gestation from 23-39 weeks (average 30 weeks) were studied with a 1.5T superconductive MR unit within 24 hours after ultrasound studies. T 2 -weighted MR imaging was performed using HASTE and T 1 -weighted MR imaging was using FLASH. Comparison of the diagnosis of MRI and ultrasound were done with autopsy or postnatal follow-up MRI. Results: Of the 24 cases, 24 fetus were found. The fetal brain, gyrus, sulcus, corpus callosum, thalamus, cerebellum, brain stem, and spinal cord were shown more clearly on MR T 2 -weighted images. T 1 -weighted images were not as good as T 2 -weighted images. Twenty-seven lesions were visualized by ultrasound and thirty-one by MRI in these twenty-four fetuses. By MRI study, two cases were conformed their ultrasound diagnosis, ten cases were completed their ultrasound diagnosis, and twelve cases were made the same diagnosis as ultrasound. Conclusion: MR has advantages in displaying fetal central nervous system anatomy over ultrasound, the quality of MR images is not affected by maternal somatotype, volume of amniotic fluid, fetal skull and the pelvic skeleton of pregnant women. Based on ultrasound, MR imaging is a valuable complement to sonography in difficult cases, it can conforming, completing, even more correcting the diagnosis made by ultrasound. (authors)

  7. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  8. MRI findings in Tolosa-Hunt syndrome before and after systemic corticosteroid therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cakirer, Sinan E-mail: scakirer@yahoo.com

    2003-02-01

    Tolosa-Hunt syndrome (THS) is characterized by painful ophthalmoplegia due to a granulomatous inflammation in the cavernous sinus. Corticosteroid therapy dramatically resolves both the clinical and radiological findings of THS. We present MRI findings of six patients with a clinical history of at least one episode of unilateral or bilateral orbital-periorbital pain, clinical findings of associated paresis of one or more of 3rd, 4th, 5th or 6th cranial nerves. All of the patients revealed an enlargement of the symptomatic cavernous sinus on magnetic resonance imaging (MRI) scans. Five patients revealed total resolution of the clinical findings within 1-8 weeks, following systemic corticosteroid treatment. One patient revealed only minor regression of clinical findings within 2 weeks after the initiation of the treatment, so the cavernous sinus lesion was reevaluated as meningioma on MRI, and the patient underwent surgical resection of the mass with resultant histopathological finding of cavernous sinus meningioma. A follow-up MRI scan was performed for five patients at the end of 8-weeks of steroid therapy. Three of these five patients showed total resolution of the cavernous sinus lesions whereas two of them revealed a partial regression of the cavernous sinus lesions. MRI findings before and after systemic corticosteroid therapy are important diagnostic criteria to put the definitive diagnosis of THS and to differentiate it from other cavernous sinus lesions that simulate THS both clinically and radiologically.

  9. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size

    Energy Technology Data Exchange (ETDEWEB)

    Fallenberg, E.M.; Renz, D.M. [Charite - Universitaetsmedizin Berlin, Clinic of Radiology, Berlin (Germany); Dromain, C. [Institut Gustave Roussy, Department of Radiology, Villejuif cedex (France); Diekmann, F. [St. Joseph-Stift Bremen, Department of Medical Imaging, Bremen (Germany); Engelken, F.; Krohn, M.; Singh, J.M.; Bick, U. [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Ingold-Heppner, B. [Charite - Universitaetsmedizin Berlin, Institute of Pathology, Berlin (Germany); Winzer, K.J. [Charite - Universitaetsmedizin Berlin, Breast Center, Department of Gynecology, Berlin (Germany)

    2014-01-15

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. (orig.)

  10. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size

    International Nuclear Information System (INIS)

    Fallenberg, E.M.; Renz, D.M.; Dromain, C.; Diekmann, F.; Engelken, F.; Krohn, M.; Singh, J.M.; Bick, U.; Ingold-Heppner, B.; Winzer, K.J.

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. (orig.)

  11. Network support for system initiated checkpoints

    Science.gov (United States)

    Chen, Dong; Heidelberger, Philip

    2013-01-29

    A system, method and computer program product for supporting system initiated checkpoints in parallel computing systems. The system and method generates selective control signals to perform checkpointing of system related data in presence of messaging activity associated with a user application running at the node. The checkpointing is initiated by the system such that checkpoint data of a plurality of network nodes may be obtained even in the presence of user applications running on highly parallel computers that include ongoing user messaging activity.

  12. Passive magnetic shielding in MRI-Linac systems

    Science.gov (United States)

    Whelan, Brendan; Kolling, Stefan; Oborn, Brad M.; Keall, Paul

    2018-04-01

    Passive magnetic shielding refers to the use of ferromagnetic materials to redirect magnetic field lines away from vulnerable regions. An application of particular interest to the medical physics community is shielding in MRI systems, especially integrated MRI-linear accelerator (MRI-Linac) systems. In these systems, the goal is not only to minimize the magnetic field in some volume, but also to minimize the impact of the shield on the magnetic fields within the imaging volume of the MRI scanner. In this work, finite element modelling was used to assess the shielding of a side coupled 6 MV linac and resultant heterogeneity induced within the 30 cm diameter of spherical volume (DSV) of a novel 1 Tesla split bore MRI magnet. A number of different shield parameters were investigated; distance between shield and magnet, shield shape, shield thickness, shield length, openings in the shield, number of concentric layers, spacing between each layer, and shield material. Both the in-line and perpendicular MRI-Linac configurations were studied. By modifying the shield shape around the linac from the starting design of an open ended cylinder, the shielding effect was boosted by approximately 70% whilst the impact on the magnet was simultaneously reduced by approximately 10%. Openings in the shield for the RF port and beam exit were substantial sources of field leakage; however it was demonstrated that shielding could be added around these openings to compensate for this leakage. Layering multiple concentric shield shells was highly effective in the perpendicular configuration, but less so for the in-line configuration. Cautious use of high permeability materials such as Mu-metal can greatly increase the shielding performance in some scenarios. In the perpendicular configuration, magnetic shielding was more effective and the impact on the magnet lower compared with the in-line configuration.

  13. Fetal central nervous system anomalies: fast MRI vs ultrasonography

    International Nuclear Information System (INIS)

    Yang Wenzhong; Xia Liming; Yang Minjie; Feng Dingyi; Hu Junwu; Zou Mingli; Wang Chengyuan; Chen Xinlin; Yang Xiaohong

    2006-01-01

    Objective: To evaluate the ability of fast MRI to detect fetal central nervous system (CNS) anomalies and to compare its performance with that of prenatal ultrasonography (US). Methods Forty-eight pregnant women were detected by conventional prenatal US and MRI. Twenty-two fetuses with CNS anomalies were conformed by autopsy and follow-up. The MR and US appearances of fetal CNS structure were compared to each other and to that of autopsy. Results: A total of 26 CNS anomalies were identified by autopsy (n=17) and follow-up (n=9) including anencephaly (n=6), rachischisis (n=2), encephalocele (n=3), congenital hydrocephalus (n=7), alobar holoprosencephaly (n=1), porencephalia (n=3), arachnoid cyst (n=2) and choroids plexus cyst (n=2). US diagnosed 24 CNS anomalies, the correct diagnostic rate was 92.3%, the false-positive rate was 3.8%, the missed-diagnostic rate was 3.8%. MRI diagnosed 23 CNS anomalies, the correct-diagnostic rate was 88.5%, the false-positive rate was 3.8% ,the missed-diagnostic rate was 7.7%. There was no difference between US and MRI (P>0.05), but MRI have larger FOV, higher tissues resolution, and can demonstrate gray-white matter in detail. Conclusions: MR imaging has a similar sensitivity to that of US in the detection of fetal CNS anomalies. (authors)

  14. An MRI-compatible hand sensory vibrotactile system

    International Nuclear Information System (INIS)

    Wang, Fa; Lakshminarayanan, Kishor; Slota, Gregory P; Seo, Na Jin; Webster, John G

    2015-01-01

    Recently, the application of vibrotactile noise to the wrist or back of the hand has been shown to enhance fingertip tactile sensory perception (Enders et al 2013), supporting the potential for an assistive device worn at the wrist, that generates minute vibrations to help the elderly or patients with sensory deficit. However, knowledge regarding the detailed physiological mechanism behind this sensory improvement in the central nervous system, especially in the human brain, is limited, hindering progress in development and use of such assistive devices. To enable investigation of the impact of vibrotactile noise on sensorimotor brain activity in humans, a magnetic resonance imaging (MRI)-compatible vibrotactile system was developed to provide vibrotactile noise during an MRI of the brain. The vibrotactile system utilizes a remote (outside the MR room) signal amplifier which provides a voltage from –40 to +40 V to drive a 12 mm diameter piezoelectric vibrator (inside the MR room). It is portable and is found to be MRI-compatible which enables its use for neurologic investigation with MRI. The system was also found to induce an improvement in fingertip tactile sensation, consistent with the previous study. (note)

  15. Ultra-low field MRI food inspection system prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kawagoe, Satoshi, E-mail: s133413@edu.tut.ac.jp; Toyota, Hirotomo; Hatta, Junichi; Ariyoshi, Seiichiro; Tanaka, Saburo, E-mail: tanakas@ens.tut.ac.jp

    2016-11-15

    Highlights: • We have developed a ULF-MRI system using HTS-SQUID for food inspection. • We developed a compact magnetically shielded box to attenuate environmental noise. • The 2D-MR image was reconstructed from the grid processing data using 2D-FFT method. • The 2D-MR images of a disk-shaped and a multiple cell water sample were obtained. • The results showed the possibility of applying the ULF-MRI system to food inspection. - Abstract: We develop an ultra-low field (ULF) magnetic resonance imaging (MRI) system using a high-temperature superconducting quantum interference device (HTS-SQUID) for food inspection. A two-dimensional (2D)-MR image is reconstructed from the grid processing raw data using the 2D fast Fourier transform method. In a previous study, we combined an LC resonator with the ULF-MRI system to improve the detection area of the HTS-SQUID. The sensitivity was improved, but since the experiments were performed in a semi-open magnetically shielded room (MSR), external noise was a problem. In this study, we develop a compact magnetically shielded box (CMSB), which has a small open window for transfer of a pre-polarized sample. Experiments were performed in the CMSB and 2D-MR images were compared with images taken in the semi-open MSR. A clear image of a disk-shaped water sample is obtained, with an outer dimension closer to that of the real sample than in the image taken in the semi-open MSR. Furthermore, the 2D-MR image of a multiple cell water sample is clearly reconstructed. These results show the applicability of the ULF-MRI system in food inspection.

  16. African Health Systems Initiative (AHSI) | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The African Health Systems Initiative (AHSI) is a 10-year Canadian International ... for strengthening African-led health systems and human resources for health. ... IDRC congratulates first cohort of Women in Climate Change Science Fellows.

  17. Fetal MRI of the urinary system

    International Nuclear Information System (INIS)

    Hoermann, Marcus; Brugger, Peter C.; Balassy, Csilla; Witzani, Linde; Prayer, Daniela

    2006-01-01

    The assessment of the urinary system is typically performed by ultrasound. Nevertheless, an ultrasound may be inconclusive in fetuses with renal diseases that result in anhydramnios or oligohydramnios. In such cases, and in other cases in which ultrasound is limited, further investigation with MR should be considered. In the following article, we will provide an overview of the most commonly encountered disorders of the urinary system and their appearance on fetal MR imaging. Fetal MR imaging can accurately diagnose a wide variety of urinary tract disorders and must be seen as a valuable complementary tool to ultrasound in the assessment of the urinary system, particularly in cases of inconclusive ultrasound findings

  18. Fetal MRI of the urinary system

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, Marcus [Department of Radiodiagnostics, Medical University of Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)]. E-mail: marcus.hoermann@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna (Austria); Balassy, Csilla [Department of Radiodiagnostics, Medical University of Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Witzani, Linde [Department of Radiodiagnostics, Medical University of Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Prayer, Daniela [Department of Radiodiagnostics, Medical University of Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)

    2006-02-15

    The assessment of the urinary system is typically performed by ultrasound. Nevertheless, an ultrasound may be inconclusive in fetuses with renal diseases that result in anhydramnios or oligohydramnios. In such cases, and in other cases in which ultrasound is limited, further investigation with MR should be considered. In the following article, we will provide an overview of the most commonly encountered disorders of the urinary system and their appearance on fetal MR imaging. Fetal MR imaging can accurately diagnose a wide variety of urinary tract disorders and must be seen as a valuable complementary tool to ultrasound in the assessment of the urinary system, particularly in cases of inconclusive ultrasound findings.

  19. Does preoperative breast MRI significantly impact on initial surgical procedure and re-operation rates in patients with screen-detected invasive lobular carcinoma?

    International Nuclear Information System (INIS)

    Sinclair, K.; Sakellariou, S.; Dawson, N.; Litherland, J.

    2016-01-01

    Aim: To investigate whether magnetic resonance imaging (MRI) changes the management of patients with screen-detected invasive lobular carcinoma (ILC). Materials and methods: A retrospective, controlled, single-centre analysis of 138 cases of screen-detected ILC was performed. All patients were assessed by a single multidisciplinary team as to whether preoperative MRI altered the initial management decision or reduced re-operation rates. Results: Forty-three percent of patients had preoperative MRI. MRI guided surgical management in 40.7% patients. Primary mastectomy rates were not significantly different between the MRI and non-MRI groups (32% and 30% respectively, p=0.71). The MRI group had a lower secondary surgery rate (6.8% versus 15.2%); however, the results did not reach statistical significance, and there were no unnecessary mastectomies. Conclusion: MRI can be used appropriately to guide primary surgery in screen-detected ILC cases and affects the initial management decision in 40.7% of patients. It does not significantly affect the overall mastectomy rate or re-operation rates, but reduces the likelihood of the latter. As a result of this review, the authors' local policy for the use of MRI in screen-detected ILC patients has been modified. For patients undergoing mastectomy for ILC, MRI is no longer performed routinely to search for contralateral malignancy as this has no proven added benefit. - Highlights: • Breast magnetic resonance imaging (MRI) allows more accurate tumour assessment and detects additional foci of disease in invasive lobular carcinoma (ILC). • Over the study's 3 year time frame, MRI guided surgical management of 40.7% screen-detected ILC patients scanned. • No statistically significant difference in mastectomy rates between MRI and non MRI groups. • Observed lower re-operation rate (6.8%-v-15.2%) in MRI group not statistically significant. • No MRI benefit for contralateral disease detection in ILC patients for

  20. Initial and follow-up MRI in a case of early diagnosed Reye's syndrome

    International Nuclear Information System (INIS)

    Ozdoba, C.; Pfenninger, J.; Schroth, G.

    1997-01-01

    Early MRI in a case of clinically established Reye's syndrome confirmed CT findings of compressed ventricles and additionally demonstrated signal alterations in the thalamus, mesencephalon and pons. On follow-up MRI the pontine lesion had vanished by 1 week later, while the thalamic lesion persisted for more than 2 months. The patient, however, recovered without neurological sequelae. (orig.). With 3 figs

  1. Superconductors Enable Lower Cost MRI Systems

    Science.gov (United States)

    2013-01-01

    The future looks bright, light, and green, especially where aircraft are concerned. The division of NASA s Fundamental Aeronautics Program called the Subsonic Fixed Wing Project is aiming to reach new heights by 2025-2035, improving the efficiency and environmental impact of air travel by developing new capabilities for cleaner, quieter, and more fuel efficient aircraft. One of the many ways NASA plans to reach its aviation goals is by combining new aircraft configurations with an advanced turboelectric distributed propulsion (TeDP) system. Jeff Trudell, an engineer at Glenn Research Center, says, "The TeDP system consists of gas turbines generating electricity to power a large number of distributed motor-driven fans embedded into the airframe." The combined effect increases the effective bypass ratio and reduces drag to meet future goals. "While room temperature components may help reduce emissions and noise in a TeDP system, cryogenic superconducting electric motors and generators are essential to reduce fuel burn," says Trudell. Superconductors provide significantly higher current densities and smaller and lighter designs than room temperature equivalents. Superconductors are also able to conduct direct current without resistance (loss of energy) below a critical temperature and applied field. Unfortunately, alternating current (AC) losses represent the major part of the heat load and depend on the frequency of the current and applied field. A refrigeration system is necessary to remove the losses and its weight increases with decreasing temperature. In 2001, a material called magnesium diboride (MgB2) was discovered to be superconducting. The challenge, however, has been learning to manufacture MgB2 inexpensively and in long lengths to wind into large coils while meeting the application requirements.

  2. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  3. Simulation of spin dynamics: a tool in MRI system development

    International Nuclear Information System (INIS)

    Stoecker, Tony; Vahedipour, Kaveh; Shah, N Jon

    2011-01-01

    Magnetic Resonance Imaging (MRI) is a routine diagnostic tool in the clinics and the method of choice in soft-tissue contrast medical imaging. It is an important tool in neuroscience to investigate structure and function of the living brain on a systemic level. The latter is one of the driving forces to further develop MRI technology, as neuroscience especially demands higher spatiotemporal resolution which is to be achieved through increasing the static main magnetic field, B 0 . Although standard MRI is a mature technology, ultra high field (UHF) systems, at B 0 ≥ 7 T, offer space for new technical inventions as the physical conditions dramatically change. This work shows that the development strongly benefits from computer simulations of the measurement process on the basis of a semi-classical, nuclear spin-1/2 treatment given by the Bloch equations. Possible applications of such simulations are outlined, suggesting new solutions to the UHF-specific inhomogeneity problems of the static main field as well as the high-frequency transmit field.

  4. Simultaneous 68Ga-DOTATOC PET/MRI in patients with gastroenteropancreatic neuroendocrine tumors: initial results.

    Science.gov (United States)

    Beiderwellen, Karsten J; Poeppel, Thorsten D; Hartung-Knemeyer, Verena; Buchbender, Christian; Kuehl, Hilmar; Bockisch, Andreas; Lauenstein, Thomas C

    2013-05-01

    The aim of this pilot study was to demonstrate the potential of simultaneously acquired 68-Gallium-DOTA-D-Phe1-Tyr3-octreotide (68Ga-DOTATOC) positron emission tomography/magnetic resonance imaging (PET/MRI) in comparison with 68Ga-DOTATOC PET/computed tomography (PET/CT) in patients with known gastroenteropancreatic neuroendocrine tumors (NETs). Eight patients (4 women and 4 men; mean [SD] age, 54 [17] years; median, 55 years; range 25-74 years) with histopathologically confirmed NET and scheduled 68Ga-DOTATOC PET/CT were prospectively enrolled for an additional integrated PET/MRI scan. Positron emission tomography/computed tomography was performed using a triple-phase contrast-enhanced full-dose protocol. Positron emission tomography/magnetic resonance imaging encompassed a diagnostic, contrast-enhanced whole-body MRI protocol. Two readers separately analyzed the PET/CT and PET/MRI data sets including their subscans in random order regarding lesion localization, count, and characterization on a 4-point ordinal scale (0, not visible; 1, benign; 2, indeterminate; and 3, malignant). In addition, each lesion was rated in consensus on a binary scale (allowing for benign/malignant only). Clinical imaging, existing prior examinations, and histopathology (if available) served as the standard of reference. In PET-positive lesions, the standardized uptake value (SUV max) was measured in consensus. A descriptive, case-oriented data analysis was performed, including determination of frequencies and percentages in detection of malignant, benign, and indeterminate lesions in connection to their localization. In addition, percentages in detection by a singular modality (such as PET, CT, or MRI) were calculated. Interobserver variability was calculated (Cohen's κ). The SUVs in the lesions in PET/CT and PET/MRI were measured, and the correlation coefficient (Pearson, 2-tailed) was calculated. According to the reference standard, 5 of the 8 patients had malignant NET lesions at

  5. MRI findings of central nervous system granulocytic sarcoma (chloroma)

    International Nuclear Information System (INIS)

    Lee, Chang Man; Kim, Myung Soon; Kim, Ik Soo; Cho, Kwan Soo

    1997-01-01

    To characterize MRI findings of central nervous system (CNS) granulocytic sarcoma (chloroma) and to analyse the points which differentiate it from other CNS tumors. We evaluated MRI in six patients with CNS granulocytic sarcoma proven by surgery or bone marrow biopsy (intracranical, one case and spine five cases). A 0.5T superconductive MR machine was used for diagnosis and, axial, coronal and sagittal T1- and T2-weighted spin echo images and Gd-DTPA enhanced T1-weighted images were obtained. We retrospectively analized the location, signal intensity, margin, contrast enhancement and homogeneity, and bony change around the tumor. MRI findings of CNS granulocytic sarcomas were as follows : one tumor was seen to be an extra-axial mass in the posterior fossa of the brain, four were epidural, and one was an epidural and presacral masses in the spine;tumor magins were lobulated and three were smooth. On T1-weighted images, all tumors were of isoignal intensity;on T2-weighted images, four were of isosignal intersity and two were of high signal intensity. Contrast enhancement was inhomogeneous in five of six cases. Bony change around the tumor was seen in two cases. On T1-weighted images, CNS granulocytic sarcomas (chloromas) were of isosignal intensity, relative to brain parenchyma or spinal cord;on T2-weighted images, they were of iso or high signal intensity, with relative contrast enhancement. These points could be useful in differentiating them from other CNS tumors

  6. Whole-body MRI in children with Langerhans cell histiocytosis for the evaluation of the skeletal system

    International Nuclear Information System (INIS)

    Steinborn, M.; Woertler, K.; Rummeny, E.J.; Nathrath, M.; Schoeniger, M.; Hahn, H.

    2008-01-01

    Purpose: the usefulness of whole-body MRI (WB-MRI) for the detection of skeletal lesions in patients with Langerhans cell histiocytosis should be documented on the basis of case presentations. Materials and methods: in six patients with histologically proven Langerhans cell histiocytosis, 14 WB-MRI examinations were performed to evaluate the skeletal system within disease staging (6 primary, 8 follow-up examinations). The examinations were performed on a 1.5 Tesla, 32-channel whole-body scanner. The examination protocol consisted of T1-weighted and STIR sequences in coronal and sagittal orientation. For comparison, radiographs of the initial skeletal lesions and those that were additionally detected on WB-MRI were available. Results: in 4 patients no additional skeletal lesions were found on WB-MRI besides the initial lesion leading to the diagnosis of unifocal single system disease. In 2 patients WB-MRI was able to identify additional skeletal lesions. In a 5 1/2 year-old boy with the primary lesion located in the cervical spine, a second lesion was detected in the lumbar spine on the initial scan and in the skull and proximal femur during follow-up examination. In a 12 year-old girl with a primary lesion of the thoracic spine, WB-MRI diagnosed additional lesions in the pelvic bone and the tibia. In both patients the diagnosis of multifocal skeletal involvement led to chemotherapy. During follow-up examination, the healing response under therapy could be demonstrated. Comparison with conventional imaging showed that especially lesions located in the spine or the pelvis were not detectable on radiographs even when knowing the MR results. (orig.)

  7. Clinical and MRI correlation in multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Negoro, Kiyoshi; Morimatsu, Mitsunori (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1994-05-01

    By using magnetic resonance imaging (MRI), we studied 11 patients with multiple system atrophy (MSA): 5 olivo-pontocerebellar atrophy (OPCA), 2 Shy-Drager syndrome (SDS), and 4 striatonigral degeneration (SND). The diagnoses of OPCA, SDS and SND were clinically made. The MR images were performed on 1.5 tesla MRI unit (Siemens Asahi Medical, Magnetom H15), using a T[sub 2]-weighted spin echo (SE) sequence (TR: 2000-3000 ms, TE: 80-90 ms), a T[sub 1]-weighted SE sequence (TR: 550, TE: 15), and a proton density-weighted (PD) SE sequence (TR: 2000-3000, TE: 12-22). In the patients with OPCA, MRI revealed cerebellar and brainstem atrophy and degeneration of pontine transverse fibers more marked than in the patients with SDS and SND. T[sub 2]-weighted images showed low intensity in posterolateral putamina in one OPCA patient and all of SDS and SND patients. PD images demonstrated the abnormal slit-like high signals in posterolateral putamina in three SND. The degree of cerebellar ataxia was not well correlated with cerebellar and brainstem atrophy and degeneration of pontine transverse fibers. There was a positive correlation between the atrophy of cerebellum and brainstem and the duration of cerebellar ataxia. In most of the patients with Parkinsonism, MRI demonstrated abnormal low signals in putamina on T[sub 2]-weighted images. There were positive correlations between the abnormal low signals putamina and the duration and severity of Parkinsonism. Though abnormal low signals in lateral putamina may be seen in normal aging and other disorders on T[sub 2]-weighted images, it is useful to evaluate Parkinsonism in MSA. We believe that the abnormal slit-like high signals in posterolateral putamina in MSA may suggest loss of neurons and gliosis. (author).

  8. Fast Initialization of Bubble-Memory Systems

    Science.gov (United States)

    Looney, K. T.; Nichols, C. D.; Hayes, P. J.

    1986-01-01

    Improved scheme several orders of magnitude faster than normal initialization scheme. State-of-the-art commercial bubble-memory device used. Hardware interface designed connects controlling microprocessor to bubblememory circuitry. System software written to exercise various functions of bubble-memory system in comparison made between normal and fast techniques. Future implementations of approach utilize E2PROM (electrically-erasable programable read-only memory) to provide greater system flexibility. Fastinitialization technique applicable to all bubble-memory devices.

  9. Robotic System for MRI-Guided Stereotactic Neurosurgery

    Science.gov (United States)

    Li, Gang; Cole, Gregory A.; Shang, Weijian; Harrington, Kevin; Camilo, Alex; Pilitsis, Julie G.; Fischer, Gregory S.

    2015-01-01

    Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for Deep Brain Stimulation (DBS) lead placement. The work describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio (SNR) variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with 3-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle. PMID:25376035

  10. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  11. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  12. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  13. Analysis of systemic lupus erythematosus (SLE) involving the central nervous system by magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kimihiro; Hara, Masako; Nakajima, Shinji and others

    1989-04-01

    Involvement of the central nervous system (CNS) commonly occurs in systemic lupus erythematosus (SLE). But definitive diagnosis remains difficult even with computed tomography (CT). In this study, we used the recently developed technique, magnetic resonance imaging (MRI) for CNS lupus and compared it with CT scans. CT was performed with a General Electric 8800 CT/T scanner. MRI was performed using a Mitsubishi Electric MMI-150 S. Ten patients with CNS lupus were divided into 3 groups. Group I included 4 cases with neurological manifestations alone. All lesions seen on CT were also detected by MRI, with greater clarity and extent. Furthermore, MRI depicted several microinfarcts in white matter without symptoms. Group II included 5 cases with psychiatric features alone. MRI detected a thalamic microinfarct in only one case while CT showed no abnormality in all cases. Group III included 1 case with both neurological and psychiatric symptoms. MRI demonstrated a small infarct of midbrain corresponding with neurological symptoms, more clearly than CT. Therefore MRI demonstrates the degree of brain involvement in SLE more accurately than CT. (author).

  14. Analysis of systemic lupus erythematosus (SLE) involving the central nervous system by magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Suzuki, Kimihiro; Hara, Masako; Nakajima, Shinji

    1989-01-01

    Involvement of the central nervous system (CNS) commonly occurs in systemic lupus erythematosus (SLE). But definitive diagnosis remains difficult even with computed tomography (CT). In this study, we used the recently developed technique, magnetic resonance imaging (MRI) for CNS lupus and compared it with CT scans. CT was performed with a General Electric 8800 CT/T scanner. MRI was performed using a Mitsubishi Electric MMI-150 S. Ten patients with CNS lupus were divided into 3 groups. Group I included 4 cases with neurological manifestations alone. All lesions seen on CT were also detected by MRI, with greater clarity and extent. Furthermore, MRI depicted several microinfarcts in white matter without symptoms. Group II included 5 cases with psychiatric features alone. MRI detected a thalamic microinfarct in only one case while CT showed no abnormality in all cases. Group III included 1 case with both neurological and psychiatric symptoms. MRI demonstrated a small infarct of midbrain corresponding with neurological symptoms, more clearly than CT. Therefore MRI demonstrates the degree of brain involvement in SLE more accurately than CT. (author)

  15. Brain MRI findings in patients with initial cerebral thrombosis and the relationship between incidental findings, aging and dementia

    International Nuclear Information System (INIS)

    Iwamoto, Toshihiko; Okada, Toyohiro; Ogawa, Kimikazu; Yanagawa, Kiyotaka; Uno, Masanobu; Takasaki, Masaru

    1994-01-01

    To estimate the relationship between aging, dementia and changes observed on magnetic resonance imaging (MRI) seen in elderly patients with cerebral thrombosis, MRI findings in 103 patients with an initial stroke event (thrombosis group) were compared with those of 37 patients with hypertension/diabetes (high risk group) and 78 patients without those disorders (low risk group). In addition to the causative lesions in the thrombosis group, periventricular hyperintensities (PVH), spotty lesions (SL), silent infarctions (SI), ventricular dilatation (VD), and cortical atrophy (CA) were analyzed in these groups. Infarctions located in the internal capsule/corona radiata were the most frequent causative lesion. Compared to the low risk group, a high incidence of patchy/diffuse PVH, SI, and severe CA was seen in both the thrombosis group and the high risk group. Widespread PVH and multiple SL increased with age in the thrombosis group, while severe CA was seen in each group. SI and VD tended to increase after age 60, though they were not significant. Dementia, diagnosed in 40 out of 78 patients, increased with age. Multivariate analysis revealed the degree of the effects of MRI findings on dementia to be marked in PVH, brain atrophy, causative lesions, and SL, in that order. These results indicated that diffuse PVH and brain atrophy, developing with age, promoted dementia in the elderly with vascular lesions. Moreover, they suggested that a variety of silent brain lesions recognized on MRI other than infarction can affect symptoms in the elderly. (author)

  16. Neoadjuvant chemotherapy evaluation by MRI volumetry in rectal cancer followed by chemoradiation and total mesorectal excision: Initial experience.

    Science.gov (United States)

    Nougaret, Stephanie; Fujii, Shinya; Addley, Helen C; Bibeau, Frederic; Pandey, Himanshu; Mikhael, Hisham; Reinhold, Caroline; Azria, David; Rouanet, Philippe; Gallix, Benoit

    2013-09-01

    To evaluate rectal cancer volumetry in predicting initial neoadjuvant chemotherapy response. Sixteen consecutive patients who underwent neoadjuvant chemotherapy (CX) before chemoradiotherapy (CRT) and surgery were enrolled in this retrospective study. Tumor volume was evaluated at the first magnetic resonance imaging (MRI), after CX and after CRT. Tumor volume regression (TVR) and downstaging were compared with histological results according to Tumor Regression Grade (TRG) to assess CX and CRT response, respectively. The mean tumor volume was 132 cm(3) ± 166 before and 56 cm(3) ± 71 after CX. TVR after CX was significantly different between patients with poor histologic response (TRG1/2) and those with good histologic response (TRG3/4) (P = 0.001). An optimal cutoff of TVR >68% (area under the curve [AUC]: 0.9, 95% confidence interval [CI]: 0.65-0.98, P = 0.0001) to predict good histology response after CX was assessed by receiver operating characteristic curve. According to previous data and this study, we defined 70% as the best cutoff values according to sensitivity (86%), specificity (100%) of TVR for predicting good histology response. In contradistinction, MRI downstaging was associated with TRG only after CRT (P = 0.04). Our pilot study showed that MRI volumetry can predict early histological response after CX and before CRT. MRI volumetry could help the clinician to distinguish early responders in order to aid appropriate individually tailored therapies. Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

  17. Can cardiovascular MRI be used to more definitively characterize cardiac masses initially identified using echocardiography?

    Science.gov (United States)

    Rathi, Vikas K; Czajka, Anna T; Thompson, Diane V; Doyle, Mark; Tewatia, Tarun; Yamrozik, June; Williams, Ronald B; Biederman, Robert W W

    2018-05-01

    In diagnosing cardiac and paracardiac masses, cardiac MRI (CMR) has gained acceptance as the gold standard. CMR has been observed to be superior to echocardiography in characterizing soft-tissue structures and, specifically, in classifying cardiac masses. The aim of our study was to evaluate the association between mortality and cardiac or paracardiac masses initially identified by echocardiography (ECHO) and confirmed by CMR. Between January 2002 and August 2007, a total of 158 patients underwent both ECHO and CMR for the evaluation of cardiac masses that were equivocal or undefined by ECHO. The primary study endpoints were 5-year all-cause mortality and 5-year cardiac mortality. Causes of death as of April 1, 2015 were obtained from medical records or the National Death Index. Patients were analyzed according to mass type determined by CMR using the Kruskal-Wallis test, Kaplan-Meier curves, and the log-rank test. Over a mean duration of follow-up of 10.4 ± 2.9 years (range: 0.01-12 years) post-CMR, the overall all-cause mortality rate was 25.9% (41/158). Median age at death was 76 years and there were 21 females (51.2%). Mortality rates in the different classifications of cardiac masses by CMR were as follows: 20% (1/5) in patients with a Nondiagnostic CMR; 20% (1/5) in Other Diagnoses; 17.9% (7/39) in No Masses (includes Normal Anatomical Variants); 16.7% (3/18) in Benign Masses; 23.8% (15/63) in Fat; 50% (5/10) in Thrombus; and 61.5% (8/13) in Malignant Mass. The mean survival time in patients with No Mass (n = 39) was not significantly longer than patients with any type of cardiac mass (n = 114) (P = .16). No significant difference was found in age at death between patients when grouped by CMR classification (P = .40). However, among CMR-confirmed masses, there were some significant differences by mass classification type (P = .006). During the follow-up period, 26% (41/158) of patients died and 22% (9/41) of the deaths were cardiovascular

  18. 3D 23Na MRI of human skeletal muscle at 7 Tesla: initial experience

    International Nuclear Information System (INIS)

    Chang, Gregory; Wang, Ligong; Regatte, Ravinder R.; Schweitzer, Mark E.

    2010-01-01

    To evaluate healthy skeletal muscle pre- and post-exercise via 7 T 23 Na MRI and muscle proton T 2 mapping, and to evaluate diabetic muscle pre- and post-exercise via 7 T 23 Na MRI. The calves of seven healthy subjects underwent imaging pre- and post-exercise via 7 T 23 Na MRI (3D fast low angle shot, TR/TE = 80 ms/0.160 ms, 4 mm x 4 mm x 4 mm) and 1 week later by 1 H MRI (multiple spin-echo sequence, TR/TE = 3,000 ms/15-90 ms). Four type 2 diabetics also participated in the 23 Na MRI protocol. Pre- and post-exercise sodium signal intensity (SI) and proton T 2 relaxation values were measured/calculated for soleus (S), gastrocnemius (G), and a control, tibialis anterior (TA). Two-tailed t tests were performed. In S/G in healthy subjects post-exercise, sodium SI increased 8-13% (p 1/2 = 22 min), and 1 H T 2 values increased 12-17% (p 1/2 = 12-15 min). In TA, no significant changes in sodium SI or 1 H T 2 values were seen (-2.4 to 1%, p > 0.17). In S/G in diabetics, sodium SI increased 10-11% (p 1/2 = 27-37 min) without significant change in the TA SI (-3.6%, p = 0.066). It is feasible to evaluate skeletal muscle via 3D 23 Na MRI at 7 T. Post-exercise muscle 1 H T 2 values return to baseline more rapidly than sodium SI. Diabetics may demonstrate delayed muscle sodium SI recovery compared with healthy subjects. (orig.)

  19. MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience

    International Nuclear Information System (INIS)

    Xiao, L.; Siu, C.W.J.; Yeung, K.; Leung, A.; Yuen, M.K.; Wong, Y.C.

    2015-01-01

    Aim: The aim of this study was to compare three-dimensional (3D) high resolution T2*-weighted gradient echo (3D FFE) magnetic resonance (MR) sequence with conventional 2D T2-weighted turbo spin echo (TSE) MR sequence for imaging of the cervical spine, especially to assess the detectability of the internal anatomy of the cervical spinal cord, i.e. to distinguish the grey and white matter. Methods: Fifteen volunteers were examined at 3.0T MR unit. Signal-to-noise (SNR), contrast-to-noise (CNR) and image homogeneity were evaluated. In the visual analysis, the visibility of anatomical structures of the cervical spine and artifacts were assessed. The nonparametric method of paired sample t-test was adopted to evaluate the differences between the sequences. Results: The 3D FFE sequence provided better results for CNR, cerebrospinal fluid (CSF) versus white matter, grey matter, disk and bone. Moreover, it yielded good results for the CNR grey matter versus white matter. The butterfly-shaped “H” is clearly displayed in the 3D FFE sequence. The statistical analysis revealed the statistically significant difference between the 2D TSE and 3D FFE sequences for the contrast of CSF versus spinal cord (both grey matter and white matter). Conclusion: The 3D FFE sequence in MR imaging of the cervical spinal cord is superior in delineation of spinal cord anatomical structures compared to 2D TSE sequence. -- Highlights: •We investigate the potential of 3D FFE sequence to distinguish the grey-white of the cervical spinal cord at 3T MRI system. •We optimized The 3D FFE sequence was optimized to increase the grey-white contrast. •Utilizing medium TE for T2W and the shortest TR for reduction of susceptibility related artifacts and motion artefacts. •This technique may increase the confidence in the diagnosis of disease with the improved delineation of cord anatomy

  20. Initial experience of oculodynamic MRI using ultrafast T2-weighted imaging

    International Nuclear Information System (INIS)

    Tanitame, Keizo; Kaichi, Yoko; Nakamura, Yuko

    2013-01-01

    We designed cine MRI protocol using sequential static half-Fourier single-shot rapid acquisition with relaxation enhancement (RARE) images with the subjects staring at the series of targets in front of their eyes. This technique was applied to three healthy volunteers and four patients with ocular motility disorders, including blow-out fracture, globe restriction due to a large posterior staphyloma, neurogenic strabismus (convergence disorder), and intraocular adhesion. In the volunteers, smooth movements of their visual foci and extraocular muscles were observed. In the patients, the ocular movement disturbances were demonstrated. Oculodynamic MRI provides functional information in cases of diplopia. (author)

  1. Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

    International Nuclear Information System (INIS)

    Manber, Richard; Thielemans, Kris; Hutton, Brian; Barnes, Anna; Ourselin, Sebastien; Arridge, Simon; O’Meara, Celia; Atkinson, David

    2014-01-01

    Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution MRI to capture motion states during respiration [1, 2]. In this work, we use a respiratory signal derived from the PET list-mode data [3, ], with no requirement for an external device or MR sequence modifications.

  2. Citizen's initiatives and the representative system

    International Nuclear Information System (INIS)

    Guggenberger, B.; Kempf, U.

    1978-01-01

    This anthology containing contributions of 19 sociologists is a systematic investigation of the locality, the possibilities and the effective radius of citizen's initiatives under the functional conditions of the parliamentary - representative system. The intellectual and political surroundings, the sociologic context, the institutional, political and judical overall conditions as well as the consequences of this movement for the whole political system of the Federal Republic of Germany. (orig.) [de

  3. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake [Nagasaki Univ. (Japan). School of Medicine; Narimatsu, Motoharu

    1997-08-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA{>=}5 cm, thickness of the false lumen of the AA{>=}1 cm, thickness of the false lumen of the AA{>=} that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  4. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    International Nuclear Information System (INIS)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake; Narimatsu, Motoharu.

    1997-01-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA≥5 cm, thickness of the false lumen of the AA≥1 cm, thickness of the false lumen of the AA≥ that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  5. MRI findings associated with development of incident knee pain over 48 months: data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, Gabby B.; Hou, Stephanie W.; Nardo, Lorenzo; Heilmeier, Ursula; Link, Thomas M. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Nevitt, Michael C.; McCulloch, Charles E. [University of California, San Francisco, Department of Epidemiology and Biostatistics, San Francisco, CA (United States)

    2016-05-15

    The purpose of this nested case-control study was to identify baseline, incident, and progressive MRI findings visible on standard MRI clinical sequences that were associated with development of incident knee pain in subjects at risk for OA over a period of 48 months. We analyzed 60 case knees developing incident pain (WOMAC{sub pain} = 0 at baseline and WOMAC{sub pain} ≥ 5 at 48 months) and 60 control knees (WOMAC{sub pain} = 0 at baseline and WOMAC{sub pain} = 0 at 48 months) from the Osteoarthritis Initiative. 3 T knee MRIs were analyzed using a modified WORMS score (cartilage, meniscus, bone marrow) at baseline and after 48 months. Baseline and longitudinal findings were grouped into logistic regression models and compared using likelihood-ratio tests. For each model that was significant, a stepwise elimination was used to isolate significant MRI findings. One baseline MRI finding and three findings that changed from baseline to 48 months were associated with the development of pain: at baseline, the severity of a cartilage lesion in the medial tibia was associated with incident pain - (odds ratio (OR) for incident pain = 3.05; P = 0.030). Longitudinally, an incident effusion (OR = 9.78; P = 0.005), a progressive cartilage lesion of the patella (OR = 4.59; P = 0.009), and an incident medial meniscus tear (OR = 4.91; P = 0.028) were associated with the development of pain. Our results demonstrate that baseline abnormalities of the medial tibia cartilage as well as an incident joint effusion, progressive patella cartilage defects, and an incident medial meniscus tear over 48 months may be associated with incident knee pain. Clinically, this study helps identify MRI findings that are associated with the development of knee pain. (orig.)

  6. MRI findings associated with development of incident knee pain over 48 months: data from the osteoarthritis initiative

    International Nuclear Information System (INIS)

    Joseph, Gabby B.; Hou, Stephanie W.; Nardo, Lorenzo; Heilmeier, Ursula; Link, Thomas M.; Nevitt, Michael C.; McCulloch, Charles E.

    2016-01-01

    The purpose of this nested case-control study was to identify baseline, incident, and progressive MRI findings visible on standard MRI clinical sequences that were associated with development of incident knee pain in subjects at risk for OA over a period of 48 months. We analyzed 60 case knees developing incident pain (WOMAC pain = 0 at baseline and WOMAC pain ≥ 5 at 48 months) and 60 control knees (WOMAC pain = 0 at baseline and WOMAC pain = 0 at 48 months) from the Osteoarthritis Initiative. 3 T knee MRIs were analyzed using a modified WORMS score (cartilage, meniscus, bone marrow) at baseline and after 48 months. Baseline and longitudinal findings were grouped into logistic regression models and compared using likelihood-ratio tests. For each model that was significant, a stepwise elimination was used to isolate significant MRI findings. One baseline MRI finding and three findings that changed from baseline to 48 months were associated with the development of pain: at baseline, the severity of a cartilage lesion in the medial tibia was associated with incident pain - (odds ratio (OR) for incident pain = 3.05; P = 0.030). Longitudinally, an incident effusion (OR = 9.78; P = 0.005), a progressive cartilage lesion of the patella (OR = 4.59; P = 0.009), and an incident medial meniscus tear (OR = 4.91; P = 0.028) were associated with the development of pain. Our results demonstrate that baseline abnormalities of the medial tibia cartilage as well as an incident joint effusion, progressive patella cartilage defects, and an incident medial meniscus tear over 48 months may be associated with incident knee pain. Clinically, this study helps identify MRI findings that are associated with the development of knee pain. (orig.)

  7. MRI-controlled interstitial ultrasound brain therapy: An initial in-vivo study

    Science.gov (United States)

    N'Djin, W. Apoutou; Burtnyk, Mathieu; Lipsman, Nir; Bronskill, Michael; Schwartz, Michael; Kucharczyk, Walter; Chopra, Rajiv

    2012-11-01

    The recent emergence at the clinical level of minimally-invasive focal therapy such as laser-induced thermal therapy (LITT) has demonstrated promise in the management of brain metastasis [1], although control over the spatial pattern of heating is limited. Delivery of HIFU from minimally-invasive applicators enables high spatial control of the heat deposition in biological tissues, large treatment volumes and high treatment rate in well chosen conditions [2,3]. In this study, the feasibility of MRI-guided interstitial ultrasound therapy in brain was studies in-vivo in a porcine model. A prototype system originally developed for transurethral ultrasound therapy [4,5,6] was used in this study. Two burr holes of 12 mm in diameter were created in the animal's skull to allow the insertion of the therapeutic ultrasound applicator (probe) into the brain at two locations (right and left frontal lobe). A 4-element linear ultrasound transducer (f = 8 MHz) was mounted at the tip of a 25-cm linear probe (6 mm in diameter). The target boundary was traced to cover in 2D a surface compatible with the treatment of a 2 cm brain tumor. Acoustic power of each element and rotation rate of the device were adjusted in real-time based on MR-thermometry feedback control to optimize heat deposition at the target boundary [2,4,5]. Two MRT-controlled ultrasound brain treatments per animal have been performed using a maximal surface acoustic power of 10W.cm-2. In all cases, it was possible to increase accurately the temperature of the brain tissues in the targeted region over the 55°C threshold necessary for the creation of irreversible thermal lesion. Tissue changes were visible on T1w contrast-enhanced images immediately after treatment. These changes were also evident on T2w FSE images taken 2 hours after the 1st treatment and correlated well with the temperature image. On average, the targeted volume was 4.7 ± 2.3 cm3 and the 55°C treated volume was 6.7 ± 4.4 cm3. The volumetric

  8. Real-time 3-dimensional virtual reality navigation system with open MRI for breast-conserving surgery

    International Nuclear Information System (INIS)

    Tomikawa, Morimasa; Konishi, Kozo; Ieiri, Satoshi; Hong, Jaesung; Uemura, Munenori; Hashizume, Makoto; Shiotani, Satoko; Tokunaga, Eriko; Maehara, Yoshihiko

    2011-01-01

    We report here the early experiences using a real-time three-dimensional (3D) virtual reality navigation system with open magnetic resonance imaging (MRI) for breast-conserving surgery (BCS). Two patients with a non-palpable MRI-detected breast tumor underwent BCS under the guidance of the navigation system. An initial MRI for the breast tumor using skin-affixed markers was performed immediately prior to excision. A percutaneous intramammary dye marker was applied to delineate an excision line, and the computer software '3D Slicer' generated a real-time 3D virtual reality model of the tumor and the puncture needle in the breast. Under guidance by the navigation system, marking procedures were performed without any difficulties. Fiducial registration errors were 3.00 mm for patient no.1, and 4.07 mm for patient no.2. The real-time 3D virtual reality navigation system with open MRI is feasible for safe and accurate excision of non-palpable MRI-detected breast tumors. (author)

  9. Value of prenatal MRI in early evaluation of fetal central nervous system anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Keiichi [Kugayama Hospital, Tokyo (Japan); Nakamura, Masanao; Hino, Ken [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine] [and others

    2002-08-01

    Advances in technology and the need for accurate prenatal diagnoses have produced great improvements in fetal diagnosis by MRI. However, there are still many problems with diagnosis of central nervous system (CNS) anomalies using MRI (e.g., time of diagnosis, factors limiting diagnostic ability. Fifteen cases referred to our clinic from 1992 to 2001 and examined using intrauterine ultrasound, prenatal MRI and postnatal MRI were reviewed retrospectively. All clinical records and findings from prenatal MRI, postnatal MRI and ultrasound were reviewed. Prenatal MRI was found to be equal in diagnostic power to ultrasound and postnatal MRI in 10 of the 15 cases. In the remaining 5 fetuses, the findings of prenatal MRI were not the same to those of prenatal ultrasound and postnatal MRI. Our goal was to determine the value of prenatal MRI in diagnosis of fetal CNS anomalies, to ascertain how this information might be used for counseling, and to assess its impact on pregnancy management. Prenatal MRI provided useful information for support personnel (e.g., physicians, nurses, caseworkers, religious advisers). (author)

  10. Modeling systemic and renal gadolinium chelate transport with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Votaw, John R.; Martin, Diego [Emory University Hospital, Department of Radiology, Atlanta, GA (United States)

    2008-01-15

    The advent of modern MRI scanners and computer equipment permits the rapid sequential collection of images of gadolinium chelate (Gd) transit through the kidney. The excellent spatial and temporal (0.9 s) resolution permits analyzing the shape of the recovered curves with a sophisticated model that includes both space and time. The purpose of this manuscript is to present such a mathematical model. By building into the model significant physical processes that contribute to the shape of the measured curve, quantitative values can be assigned to important parameters. In this work, quantitative values are determined for blood dispersion through the cardio-pulmonary system, systemic clearance rate of Gd, blood flow into each kidney, blood transit time in each kidney, the extraction rate of Gd across the capillary membrane, interstitial distribution volume, and the GFR for each kidney. (orig.)

  11. Quantitative evaluation of the reticuloendothelial system function with dynamic MRI.

    Directory of Open Access Journals (Sweden)

    Ting Liu

    Full Text Available To evaluate the reticuloendothelial system (RES function by real-time imaging blood clearance as well as hepatic uptake of superparamagnetic iron oxide nanoparticle (SPIO using dynamic magnetic resonance imaging (MRI with two-compartment pharmacokinetic modeling.Kinetics of blood clearance and hepatic accumulation were recorded in young adult male 01b74 athymic nude mice by dynamic T2* weighted MRI after the injection of different doses of SPIO nanoparticles (0.5, 3 or 10 mg Fe/kg. Association parameter, Kin, dissociation parameter, Kout, and elimination constant, Ke, derived from dynamic data with two-compartment model, were used to describe active binding to Kupffer cells and extrahepatic clearance. The clodrosome and liposome were utilized to deplete macrophages and block the RES function to evaluate the capability of the kinetic parameters for investigation of macrophage function and density.The two-compartment model provided a good description for all data and showed a low sum squared residual for all mice (0.27±0.03. A lower Kin, a lower Kout and a lower Ke were found after clodrosome treatment, whereas a lower Kin, a higher Kout and a lower Ke were observed after liposome treatment in comparison to saline treatment (P<0.005.Dynamic SPIO-enhanced MR imaging with two-compartment modeling can provide information on RES function on both a cell number and receptor function level.

  12. Direct cerebral and cardiac 17O-MRI at 3 Tesla: initial results at natural abundance.

    Science.gov (United States)

    Borowiak, Robert; Groebner, Jens; Haas, Martin; Hennig, Jürgen; Bock, Michael

    2014-02-01

    To establish direct (17)O-magnetic resonance imaging (MRI) for metabolic imaging at a clinical field strength of 3 T. An experimental setup including a surface coil and transmit/receive switch was constructed. Natural abundance in vivo brain images of a volunteer were acquired with a radial three-dimensional (3D) sequence in the visual cortex and in the heart with electrocardiogram (ECG)-gating. In the brain, a signal-to-noise ratio of 36 was found at a nominal resolution of (5.6 mm)(3), and a transverse relaxation time of T(2)* = (1.9 ± 0.2) ms was obtained. In the heart (17)O images were acquired with a temporal resolution of 200 ms. Cerebral and cardiac (17)O-MRI at natural abundance is feasible at 3 T.

  13. Arterial spin labelling perfusion MRI of breast cancer using FAIR TrueFISP: Initial results

    International Nuclear Information System (INIS)

    Buchbender, S.; Obenauer, S.; Mohrmann, S.; Martirosian, P.; Buchbender, C.; Miese, F.R.; Wittsack, H.J.; Miekley, M.; Antoch, G.; Lanzman, R.S.

    2013-01-01

    Aim: To assess the feasibility of an unenhanced, flow-sensitive, alternating inversion recovery-balanced steady-state free precession (FAIR TrueFISP) arterial spin labelling (ASL) magnetic resonance imaging (MRI) technique for quantification of breast cancer perfusion. Materials and methods: Eighteen untreated breast tumour patients (mean age 53 ± 17 years, range 30–68 years) and four healthy controls (mean age 51 ± 14 years, range 33–68 years) were enrolled in this study and were imaged using a clinical 1.5 T MRI machine. Perfusion measurements were performed using a coronal single-section ASL FAIR TrueFISP technique in addition to a routine breast MRI examination. T1 relaxation time of normal breast parenchyma was determined in four healthy volunteers using the variable flip angle approach. The definitive diagnosis was obtained at histology after biopsy or surgery and was available for all patients. Results: ASL perfusion was successfully acquired in 13 of 18 tumour patients and in all healthy controls. The mean ASL perfusion of invasive ductal carcinoma tissue was significantly higher (88.2 ± 39.5 ml/100 g/min) compared to ASL perfusion of normal breast parenchyma (24.9 ± 12.7 ml/100 g/min; p < 0.05) and invasive lobular carcinoma (30.5 ± 4.3 ml/100 g/min; p < 0.05). No significant difference was found between the mean ASL perfusion of normal breast parenchyma and invasive lobular carcinoma tissue (p = 0.97). Conclusion: ASL MRI enables quantification of breast cancer perfusion without the use of contrast material. However, its impact on diagnosis and therapy management of breast tumours has to be evaluated in larger patient studies

  14. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  15. Initial experiments with gel-water: towards MRI-linac dosimetry and imaging.

    Science.gov (United States)

    Alnaghy, Sarah J; Gargett, Maegan; Liney, Gary; Petasecca, Marco; Begg, Jarrad; Espinoza, Anthony; Newall, Matthew K; Duncan, Mitchell; Holloway, Lois; Lerch, Michael L F; Lazea, Mircea; Rosenfeld, Anatoly B; Metcalfe, Peter

    2016-12-01

    Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR 20/10 ), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR 20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.

  16. Functional magnetic resonance imaging (fMRI) for fetal oxygenation during maternal hypoxia: initial results

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Adam, G.; Tchirikov, M.; Schroeder, H.; Koch, M.

    2002-01-01

    Purpose: To investigate the potential of fMRI to measure changes in fetal tissue oxygenation during acute maternal hypoxia in fetal lambs. Material and Methods: Two ewes carrying singleton fetuses (gestational age 125 and 131 days) underwent MR imaging under inhalation anesthesia. BOLD imaging of the fetal brain, liver and myocardium was performed during acute maternal hypoxia (oxygen replaced by N 2 O). Maternal oxygen saturation and heart rate were monitored by a pulse-oxymeter attached to the maternal tongue. Results: Changes of fetal tissue oxygenation during maternal hypoxia were clearly visible with BOLD MRI. Signal intensity decreases were more distinct in liver and heart (∝40%) from control than in the fetal brain (∝10%). Conclusions: fMRI is a promising diagnostic tool to determine fetal tissue oxygenation and may open new opportunities in monitoring fetal well being in high risk pregnancies complicated by uteroplacentar insufficiency. Different signal changes in liver/heart and brain may reflect a centralization of the fetal blood flow. (orig.) [de

  17. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  18. Techniques for Interventional MRI Guidance in Closed-Bore Systems.

    Science.gov (United States)

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2018-02-01

    Efficient image guidance is the basis for minimally invasive interventions. In comparison with X-ray, computed tomography (CT), or ultrasound imaging, magnetic resonance imaging (MRI) provides the best soft tissue contrast without ionizing radiation and is therefore predestined for procedural control. But MRI is also characterized by spatial constraints, electromagnetic interactions, long imaging times, and resulting workflow issues. Although many technical requirements have been met over the years-most notably magnetic resonance (MR) compatibility of tools, interventional pulse sequences, and powerful processing hardware and software-there is still a large variety of stand-alone devices and systems for specific procedures only.Stereotactic guidance with the table outside the magnet is common and relies on proper registration of the guiding grids or manipulators to the MR images. Instrument tracking, often by optical sensing, can be added to provide the physicians with proper eye-hand coordination during their navigated approach. Only in very short wide-bore systems, needles can be advanced at the extended arm under near real-time imaging. In standard magnets, control and workflow may be improved by remote operation using robotic or manual driving elements.This work highlights a number of devices and techniques for different interventional settings with a focus on percutaneous, interstitial procedures in different organ regions. The goal is to identify technical and procedural elements that might be relevant for interventional guidance in a broader context, independent of the clinical application given here. Key challenges remain the seamless integration into the interventional workflow, safe clinical translation, and proper cost effectiveness.

  19. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Kjel [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: kjel_andersen@web.de; Hennersdorf, Marcus [Department of Cardiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: hennersdorf@med.uni-duesseldorf.de; Cohnen, Mathias [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: cohnen@med.uni-duesseldorf.de; Blondin, Dirk [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de; Moedder, Ulrich [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: moedder@uni-duesseldorf.de; Poll, Ludger W. [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: poll@gmx.de

    2009-07-15

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  20. Hypoxia in Prostate Cancer: Correlation of BOLD-MRI With Pimonidazole Immunohistochemistry-Initial Observations

    International Nuclear Information System (INIS)

    Hoskin, Peter J.; Carnell, Dawn M.; Taylor, N. Jane; Smith, Rowena E.; Stirling, J. James; Daley, Frances M.; Saunders, Michele I.; Bentzen, Soren M.; Collins, David J.; D'Arcy, James A.; Padhani, Anwar P.

    2007-01-01

    Purpose: To investigate the ability of blood oxygen level-dependent (BOLD) MRI to depict clinically significant prostate tumor hypoxia. Methods and Materials: Thirty-three patients with prostate carcinoma undergoing radical prostatectomy were studied preoperatively, using gradient echo sequences without and with contrast medium enhancement, to map relative tissue oxygenation according to relaxivity rates and relative blood volume (rBV). Pimonidazole was administered preoperatively, and whole-mount sections of selected tumor-bearing slices were stained for pimonidazole fixation and tumor and nontumor localization. Histologic and imaging parameters were independently mapped onto patient prostate outlines. Using 5-mm grids, 861 nontumor grid locations were compared with 237 tumor grids (with >50% tumor per location) using contingency table analysis with respect to the ability of imaging to predict pimonidazole staining. Results: Twenty patients completed the imaging and histologic protocols. Pimonidazole staining was found in 33% of nontumor and in 70% of tumor grids. The sensitivity of the MR relaxivity parameter R 2 * in depicting tumor hypoxia was high (88%), improving with the addition of low rBV information (95%) without changing specificity (36% and 29%, respectively). High R 2 * increased the positive predictive value for hypoxia by 6% (70% to 76%); conversely, low R 2 * decreased the likelihood of hypoxia being present by 26% (70% to 44%) and by 41% (71% to 30%) when combined with rBV information. Conclusion: R 2 * maps from BOLD-MRI have high sensitivity but low specificity for defining intraprostatic tumor hypoxia. This together with the negative predictive value of 70% when combined with blood volume information makes BOLD-MRI a potential noninvasive technique for mapping prostatic tumor hypoxia

  1. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    International Nuclear Information System (INIS)

    Andersen, Kjel; Hennersdorf, Marcus; Cohnen, Mathias; Blondin, Dirk; Moedder, Ulrich; Poll, Ludger W.

    2009-01-01

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  2. The OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging (MRI) Scoring System: Updated Recommendations by the OMERACT MRI in Arthritis Working Group.

    Science.gov (United States)

    Østergaard, Mikkel; Peterfy, Charles G; Bird, Paul; Gandjbakhch, Frédérique; Glinatsi, Daniel; Eshed, Iris; Haavardsholm, Espen A; Lillegraven, Siri; Bøyesen, Pernille; Ejbjerg, Bo; Foltz, Violaine; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2017-11-01

    The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables to have face, construct, and criterion validity; high reliability and sensitivity to change; and the ability to discriminate between therapies. This has enabled RAMRIS to demonstrate inhibition of structural damage progression with fewer patients and shorter followup times than has been possible with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis. These have high reproducibility and moderate sensitivity to change, and can be added to RAMRIS. Combined scores of inflammation or joint damage may increase sensitivity to change and discriminative power. However, this requires further research. Updated 2016 RAMRIS recommendations and a research agenda were developed.

  3. Evaluation of femoral perfusion in a rabbit model of steroid-induced osteonecrosis by dynamic contrast-enhanced MRI with a high magnetic field MRI system.

    Science.gov (United States)

    Hayashi, Shigeki; Fujioka, Mikihiro; Ikoma, Kazuya; Saito, Masazumi; Ueshima, Keiichiro; Ishida, Masashi; Kuribayashi, Masaaki; Ikegami, Akira; Mazda, Osam; Kubo, Toshikazu

    2015-04-01

    To evaluate perfusion during the early phase after steroid administration in vivo using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with a high magnetic field MRI system. The main pathogenesis of steroid-induced osteonecrosis is considered to be ischemia. A single dose of methylprednisolone (MPSL) was injected into nine rabbits. DCE-MRI was performed for these rabbits before MPSL administration and 1, 5, 10, and 14 days after administration. Time-signal intensity curves were created for each femur based on the signal intensity to evaluate perfusion. Enhancement ratio (ER), initial slope (IS), and area under the curve (AUC) were calculated and the value before MPSL administration and the minimal value after administration were compared statistically. ER, IS, and AUC values after MPSL administration significantly decreased (P < 0.05, P < 0.01, and P < 0.01, respectively). All of them decreased by the 5th day in 56% of the femora and by the 14th day in 83%, and some femora even showed a decrease from the 1st day. In this study, decreased perfusion in the femora after steroid administration was proven. Additionally, we could show that it occurred from the early days after steroid administration. © 2014 Wiley Periodicals, Inc.

  4. Noninvasive measurement of liver iron concentration at MRI in children with acute leukemia: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Vag, Tibor; Krumbein, Ines; Reichenbach, Juergen R.; Lopatta, Eric; Stenzel, Martin; Kaiser, Werner A.; Mentzel, Hans-Joachim [Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Jena (Germany); Kentouche, Karim; Beck, James [Friedrich Schiller University Jena, Department of Pediatrics, Jena (Germany); Renz, Diane M. [Charite University Medicine Berlin, Department of Radiology, Campus Virchow Clinic, Berlin (Germany)

    2011-08-15

    Routine assessment of body iron load in patients with acute leukemia is usually done by serum ferritin (SF) assay; however, its sensitivity is impaired by different conditions including inflammation and malignancy. To estimate, using MRI, the extent of liver iron overload in children with acute leukemia and receiving blood transfusions, and to examine the association between the degree of hepatic iron overload and clinical parameters including SF and the transfusion iron load (TIL). A total of 25 MRI measurements of the liver were performed in 15 children with acute leukemia (mean age 9.75 years) using gradient-echo sequences. Signal intensity ratios between the liver and the vertebral muscle (L/M ratio) were calculated and compared with SF-levels. TIL was estimated from the cumulative blood volume received, assuming an amount of 200 mg iron per transfused red blood cell unit. Statistical analysis revealed good correlation between the L/M SI ratio and TIL (r = -0.67, P = 0.002, 95% confidence interval CI = -0.83 to -0.34) in patients with acute leukemia as well as between L/M SI ratio and SF (r = -0.76, P = 0.0003, 95% CI = -0.89 to -0.52). SF may reliably reflect liver iron stores as a routine marker in patients suffering from acute leukemia. (orig.)

  5. MR guidance and thermometry of percutaneous laser disc decompression in open MRI: an initial clinical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, Florian; Walter, Thula; Bucourt, Maximilian de; Freyhardt, Patrick; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Teichgraeber, Ulf K.M. [Charite, Humboldt-University Medical School, Department of Radiology, Berlin (Germany); Hartwig, Tony; Putzier, Michael; Strube, Patrick [Charite, Humboldt-University, Center for Musculoskeletal Surgery, Berlin (Germany); Bretschneider, Tina [University of Magdeburg, Department of Radiology, Magdeburg (Germany)

    2013-10-15

    To assess the feasibility, safety and efficacy of real-time MR guidance and thermometry of percutaneous laser disc decompression (PLDD). Twenty-four discs in 22 patients with chronic low-back and radicular pain were treated by PLDD using open 1.0-T magnetic-resonance imaging (MRI). A fluoroscopic proton-density-weighted turbo spin-echo (PDw TSE) sequence was used to position the laser fibre. Non-spoiled gradient-echo (GRE) sequences were employed for real-time thermal monitoring based on proton resonance frequency (PRF). Radicular pain was assessed over 6 months with a numerical rating scale (NRS). PLDD was technically successful in all cases, with adequate image quality for laser positioning. The PRF-based real-time temperature monitoring was found to be feasible in practice. After 6 months, 21 % reported complete remission of radicular pain, 63 % at least great pain relief and 74 % at least mild relief. We found a significant decrease in the NRS score between the pre-intervention and the 6-month follow-up assessment (P < 0.001). No major complications occurred; the single adverse event recorded, moderate motor impairment, resolved. Real-time MR guidance and PRF-based thermometry of PLDD in the lumbar spine under open 1.0-T MRI appears feasible, safe and effective and may pave the way to more precise operating procedures. (orig.)

  6. MR guidance and thermometry of percutaneous laser disc decompression in open MRI: an initial clinical investigation

    International Nuclear Information System (INIS)

    Streitparth, Florian; Walter, Thula; Bucourt, Maximilian de; Freyhardt, Patrick; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Teichgraeber, Ulf K.M.; Hartwig, Tony; Putzier, Michael; Strube, Patrick; Bretschneider, Tina

    2013-01-01

    To assess the feasibility, safety and efficacy of real-time MR guidance and thermometry of percutaneous laser disc decompression (PLDD). Twenty-four discs in 22 patients with chronic low-back and radicular pain were treated by PLDD using open 1.0-T magnetic-resonance imaging (MRI). A fluoroscopic proton-density-weighted turbo spin-echo (PDw TSE) sequence was used to position the laser fibre. Non-spoiled gradient-echo (GRE) sequences were employed for real-time thermal monitoring based on proton resonance frequency (PRF). Radicular pain was assessed over 6 months with a numerical rating scale (NRS). PLDD was technically successful in all cases, with adequate image quality for laser positioning. The PRF-based real-time temperature monitoring was found to be feasible in practice. After 6 months, 21 % reported complete remission of radicular pain, 63 % at least great pain relief and 74 % at least mild relief. We found a significant decrease in the NRS score between the pre-intervention and the 6-month follow-up assessment (P < 0.001). No major complications occurred; the single adverse event recorded, moderate motor impairment, resolved. Real-time MR guidance and PRF-based thermometry of PLDD in the lumbar spine under open 1.0-T MRI appears feasible, safe and effective and may pave the way to more precise operating procedures. (orig.)

  7. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  8. Functional magnetic resonance imaging (fMRI) for fetal oxygenation during maternal hypoxia: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Adam, G. [Abt. fuer Diagnostische und Interventionelle Radiologie, Klinik und Poliklinik fuer Radiologie, UKE Hamburg (Germany); Tchirikov, M.; Schroeder, H. [Abt. fuer experimentelle Gynaekologie der Universitaetsfrauenklinik, Klinik und Poliklinik fuer Frauenheilkunde, UKE, Hamburg (Germany); Koch, M. [Klinik und Poliklinik fuer Neurologie, UKE Hamburg (Germany)

    2002-06-01

    Purpose: To investigate the potential of fMRI to measure changes in fetal tissue oxygenation during acute maternal hypoxia in fetal lambs. Material and Methods: Two ewes carrying singleton fetuses (gestational age 125 and 131 days) underwent MR imaging under inhalation anesthesia. BOLD imaging of the fetal brain, liver and myocardium was performed during acute maternal hypoxia (oxygen replaced by N{sub 2}O). Maternal oxygen saturation and heart rate were monitored by a pulse-oxymeter attached to the maternal tongue. Results: Changes of fetal tissue oxygenation during maternal hypoxia were clearly visible with BOLD MRI. Signal intensity decreases were more distinct in liver and heart ({proportional_to}40%) from control than in the fetal brain ({proportional_to}10%). Conclusions: fMRI is a promising diagnostic tool to determine fetal tissue oxygenation and may open new opportunities in monitoring fetal well being in high risk pregnancies complicated by uteroplacentar insufficiency. Different signal changes in liver/heart and brain may reflect a centralization of the fetal blood flow. (orig.) [German] Ziel: Untersuchung des Potentiales der funktionellen MRT (BOLD) in der Darstellung von Veraenderungen in der Sauerstoffsaettigung fetaler Gewebe waehrend akuter materner Hypoxie bei fetalen Laemmern. Material und Methoden: Die MR-Untersuchung wurde an zwei Mutterschafen mit 125 und 131 Tage alten Feten in Inhalationsnarkose durchgefuehrt. Die BOLD Messungen von fetaler Leber, Myokard und Gehirn erfolgten waehrend einer akuten Hypoxiephase des Muttertieres, in der Sauerstoff durch N{sub 2}O ersetzt wurde. Die materne Sauerstoffsaettigung und Herzfrequenz wurde durch ein Pulsoxymeter ueberwacht. Ergebnisse: Aenderungen der fetalen Gewebsoxygenierung waehrend einer akuten Hypoxiephase der Mutter waren mit der BOLD-MR-Bildgebung deutlich darstellbar. In der fetalen Leber und dem Myokard zeigte sich ein staerkerer Signalabfall um ca. 40% von den Kontrollwerten als im fetalen

  9. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  10. Acoustic fMRI noise : Linear time-invariant system model

    NARCIS (Netherlands)

    Sierra, Carlos V. Rizzo; Versluis, Maarten J.; Hoogduin, Johannes M.; Duifhuis, Hendrikus (Diek)

    Functional magnetic resonance imaging (fMRI) enables sites of brain activation to be localized in human subjects. For auditory system studies, however, the acoustic noise generated by the scanner tends to interfere with the assessments of this activation. Understanding and modeling fMRI acoustic

  11. Vantage TitanTM 3T 3-tesla MRI system with enhanced serviceability and comfort

    International Nuclear Information System (INIS)

    Kanazawa, Hitoshi; Okamoto, Kazuya; Yamamoto, Takao

    2011-01-01

    Since 3-tesla magnetic resonance imaging (MRI) systems appeared on the market, in addition to their clinical usefulness a variety of issues have been pointed out in the clinical setting. The 3-tesla MRI system has therefore gained a reputation as a difficult system suitable only for hospital facilities including university hospitals that specialize in medical research. To rectify this situation, Toshiba Medical Systems Corporation has developed the Vantage Titan TM 3T, which is expected to not only improve the MRI examination environment, but also to be applicable to patients with claustrophobia and those with large physiques for whom MRI examination has not been appropriate until now, while maintaining the clinical usefulness of the 3-tesla MRI system. The Vantage Titan 3T system also incorporates the Pianissimo TM noise reduction mechanism, which has already been introduced in our 1.5-tesla MRI system and has been highly evaluated by the market. This reduces the stress of patients by providing a quieter and more open examination environment compared with conventional MRI systems. (author)

  12. SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

    International Nuclear Information System (INIS)

    Padgett, K; Pollack, A; Stoyanova, R; Swallen, A; Nelson, A

    2016-01-01

    Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing

  13. SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

    Energy Technology Data Exchange (ETDEWEB)

    Padgett, K; Pollack, A; Stoyanova, R [University of Miami, Miami, Florida (United States); Swallen, A; Nelson, A [MIM Software Inc., Cleveland, OH (United States)

    2016-06-15

    Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing

  14. Diffusion microscopist simulator - The development and application of a Monte Carlo simulation system for diffusion MRI

    International Nuclear Information System (INIS)

    Yeh, C.H.

    2011-09-01

    Diffusion magnetic resonance imaging (dMRI) has made a significant breakthrough in neurological disorders and brain research thanks to its exquisite sensitivity to tissue cyto-architecture. However, as the water diffusion process in neuronal tissues is a complex biophysical phenomena at molecular scale, it is difficult to infer tissue microscopic characteristics on a voxel scale from dMRI data. The major methodological contribution of this thesis is the development of an integrated and generic Monte Carlo simulation framework, 'Diffusion Microscopist Simulator' (DMS), which has the capacity to create 3D biological tissue models of various shapes and properties, as well as to synthesize dMRI data for a large variety of MRI methods, pulse sequence design and parameters. DMS aims at bridging the gap between the elementary diffusion processes occurring at a micrometric scale and the resulting diffusion signal measured at millimetric scale, providing better insights into the features observed in dMRI, as well as offering ground-truth information for optimization and validation of dMRI acquisition protocols for different applications. We have verified the performance and validity of DMS through various benchmark experiments, and applied to address particular research topics in dMRI. Based on DMS, there are two major application contributions in this thesis. First, we use DMS to investigate the impact of finite diffusion gradient pulse duration (delta) on fibre orientation estimation in dMRI. We propose that current practice of using long delta, which is enforced by the hardware limitation of clinical MRI scanners, is actually beneficial for mapping fibre orientations, even though it violates the underlying assumption made in q-space theory. Second, we employ DMS to investigate the feasibility of estimating axon radius using a clinical MRI system. The results suggest that the algorithm for mapping the direct microstructures is applicable to dMRI data acquired from

  15. Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system.

    Science.gov (United States)

    Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng

    2016-03-01

    To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.

  16. Initial results of shoulder MRI in external rotation after primary shoulder dislocation and after immobilization in external rotation

    International Nuclear Information System (INIS)

    Pennekamp, W.; Nicolas, V.; Gekle, C.; Seybold, D.

    2006-01-01

    Purpose: A change in the strategy for treating primary anterior traumatic dislocation of the shoulder has occurred. To date, brief fixation of internal rotation via a Gilchrist bandage has been used. Depending on the patient's age, a redislocation is seen in up to 90% of cases. This is due to healing of the internally rotated labrum-ligament tear in an incorrect position. In the case of external rotation of the humerus, better repositioning of the labrum ligament complex is achieved. Using MRI of the shoulder in external rotation, the extent of the improved labrum-ligament adjustment can be documented, and the indication of immobilization of the shoulder in external rotation can be derived. The aim of this investigation is to describe the degree of position changing of the labrum-ligament tear in internal and external rotation. Materials and Methods: 10 patients (9 male, 1 female, mean age 30.4 years, range 15-43 years) with a primary anterior dislocation of the shoulder without hyper laxity of the contra lateral side and labrum-ligament lesion substantiated by MRI were investigated using a standard shoulder MRI protocol (PD-TSE axial fs, PD-TSE coronar fs, T2-TSE sagittal, T1-TSE coronar) by an axial PD-TSE sequence in internal and external rotation. The dislocation and separation of the anterior labrum-ligament complex were measured. The shoulders were immobilized in 10 external rotation for 3 weeks. After 6 weeks a shoulder MRI in internal rotation was performed. Results: In all patients there was a significantly better position of the labrum-ligament complex of the inferior rim in external rotation, because of the tension of the ventral capsule and the subscapular muscle. In the initial investigation, the separation of the labrum-ligament complex in internal rotation was 0.44±0.27 mm and the dislocation was 0.45±0.33 mm. In external rotation the separation was 0.01±0.19 mm and the dislocation was -0.08±0.28 mm. After 6 weeks of immobilization in 10 external

  17. Initial Validation for the Estimation of Resting-State fMRI Effective Connectivity by a Generalization of the Correlation Approach

    Directory of Open Access Journals (Sweden)

    Nan Xu

    2017-05-01

    Full Text Available Resting-state functional MRI (rs-fMRI is widely used to noninvasively study human brain networks. Network functional connectivity is often estimated by calculating the timeseries correlation between blood-oxygen-level dependent (BOLD signal from different regions of interest (ROIs. However, standard correlation cannot characterize the direction of information flow between regions. In this paper, we introduce and test a new concept, prediction correlation, to estimate effective connectivity in functional brain networks from rs-fMRI. In this approach, the correlation between two BOLD signals is replaced by a correlation between one BOLD signal and a prediction of this signal via a causal system driven by another BOLD signal. Three validations are described: (1 Prediction correlation performed well on simulated data where the ground truth was known, and outperformed four other methods. (2 On simulated data designed to display the “common driver” problem, prediction correlation did not introduce false connections between non-interacting driven ROIs. (3 On experimental data, prediction correlation recovered the previously identified network organization of human brain. Prediction correlation scales well to work with hundreds of ROIs, enabling it to assess whole brain interregional connectivity at the single subject level. These results provide an initial validation that prediction correlation can capture the direction of information flow and estimate the duration of extended temporal delays in information flow between regions of interest ROIs based on BOLD signal. This approach not only maintains the high sensitivity to network connectivity provided by the correlation analysis, but also performs well in the estimation of causal information flow in the brain.

  18. Fission Surface Power System Initial Concept Definition

    Science.gov (United States)

    2010-01-01

    Under the NASA Exploration Technology Development Program (ETDP) and in partnership with the Department of Energy (DOE), NASA has embarked on a project to develop Fission Surface Power (FSP) technology. The primary goals of the project are to 1) develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options, 2) establish a hardwarebased technical foundation for FSP design concepts and reduce overall development risk, 3) reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates, and 4) generate the key products to allow NASA decision-makers to consider FSP as a preferred option for flight development. The FSP project was initiated in 2006 as the Prometheus Program and the Jupiter Icy Moons Orbiter (JIMO) mission were phased-out. As a first step, NASA Headquarters commissioned the Affordable Fission Surface Power System Study to evaluate the potential for an affordable FSP development approach. With a cost-effective FSP strategy identified, the FSP team evaluated design options and selected a Preliminary Reference Concept to guide technology development. Since then, the FSP Preliminary Reference Concept has served as a point-of-departure for several NASA mission architecture studies examining the use of nuclear power and has provided the foundation for a series of "Pathfinder" hardware tests. The long-term technology goal is a Technology Demonstration Unit (TDU) integrated system test using full-scale components and a non-nuclear reactor simulator. The FSP team consists of Glenn Research Center (GRC), Marshall Space Flight Center (MSFC) and the DOE National Laboratories at Los Alamos (LANL), Idaho (INL), Oak Ridge (ORNL), and Sandia (SNL). The project is organized into two main elements: Concept Definition and Risk Reduction. Under Concept Definition, the team performs trade studies, develops analytical tools, and formulates system concepts. Under Risk

  19. Third Degree Skin Burns Caused by an MRI Compatible Electrocardiographic Monitoring System

    DEFF Research Database (Denmark)

    Brix, Lau; Isaksen, Christin Rosendahl Graff; Kristensen, Birgitte Hornbæk

    of the assigned compatibility specifications of the leads due to the use of TFE sequences with high SAR values. MRI compatible monitoring systems are only safe when used with proper care. The presented burn cases may have been avoided if space had been provided between the ECG leads and the skin using a cloth....... This holds true even in cases in which the devices are MRI compatible and therefore safe in specified MRI environments. Of particular interest to this case report is skin burns caused by the ECG monitoring equipment. In this context, several cases of ECG electrode related burns have been reported, while...... burns caused by the ECG cables are less common [1]. This case report presents two unusual cases of skin burns which were caused by MRI safe ECG leads during scanning. Cases:Two patients suffered third degree burns using MRI approved ECG leads (Medrad® Veris MR Monitor system) in a Siemens Skyra 3...

  20. MRI of 'brain death'

    International Nuclear Information System (INIS)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira; Sanou, Kazuo.

    1990-01-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author)

  1. Initial study on in vivo conductivity mapping of breast cancer using MRI.

    Science.gov (United States)

    Shin, Jaewook; Kim, Min Jung; Lee, Joonsung; Nam, Yoonho; Kim, Min-Oh; Choi, Narae; Kim, Sooyeon; Kim, Dong-Hyun

    2015-08-01

    To develop and apply a method to measure in vivo electrical conductivity values using magnetic resonance imaging (MRI) in subjects with breast cancer. A recently developed technique named MREPT (MR electrical properties tomography) together with a novel coil combination process was used to quantify the conductivity values. The overall technique was validated using a phantom study. In addition, 90 subjects were imaged (50 subjects with previously biopsy-confirmed breast tumor and 40 normal subjects), which was approved by our institutional review board (IRB). A routine clinical protocol, specifically a T2 -weighted FSE (fast spin echo) imaging data, was used for reconstruction of conductivity. By employing the coil combination, the relative error in the conductivity map was reduced from ~70% to 10%. The average conductivity values in breast cancers regions (0.89 ± 0.33S/m) was higher compared to parenchymal tissue (0.43 S/m, P conductivity compared to benign cases (0.56 S/m, n = 5) (P conductivity compared to in situ cancers (0.57 S/m) (P conductivity mapping of breast cancers is feasible using a noninvasive in vivo MREPT technique combined with a coil combination process. The method may provide a tool in the MR diagnosis of breast cancer. © 2014 Wiley Periodicals, Inc.

  2. MRI study of degenerative process in multiple system atrophy

    International Nuclear Information System (INIS)

    Yagishita, Toshiyuki; Kojima, Shigeyuki; Hirayama, Keizo

    1995-01-01

    The characteristic morphological changes of the brainstem and cerebellar regions of multiple system atrophy (MSA) were studied by MRI in varing subtypes, that is olivoponto cerebellar atrophy (OPCA: 23 cases), striatonigral degeneration (SND: 7 cases) and Shy-Drager's syndrome (SDS: 9 cases). OPCA was characterized by atrophy of the entire regions of the brainstem and the cerebellum. SND and SDS tended to show atrophy similar in type but lessin extent to OPCA. The common lesions in MSA were atrophy of the pontine base and cerebellum, and dilation of the fourth ventricle. Atrophy of the pontine base was more dominant in the inferior part than in the superior part, and cerebellar atrophy was more dominant in the superior part than in the inferior part, indicating that degeneration of the pontocerebellar pathway proceeds principally along fibers connecting the inferior part of the pons and the superior part of the cerebellum. Dilation of the fourth ventricle indicated atrophy of the middle cerebellar peduncle. In almost all the cases of OPCA and about a half the cases of SND and SDS, the pontine base and the middle cerebellar peduncle appeared as high signal intensity on T 2 weighted image and as low intensity on T 1 , suggesting degeneration and demyelination. In a few cases of OPCA, the dorsolateral part of the putamen were demonstrated as low signal intensity on T 2 weighted image. (author)

  3. MRI study of degenerative process in multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Yagishita, Toshiyuki; Kojima, Shigeyuki; Hirayama, Keizo [Chiba Univ. (Japan). School of Medicine

    1995-02-01

    The characteristic morphological changes of the brainstem and cerebellar regions of multiple system atrophy (MSA) were studied by MRI in varing subtypes, that is olivoponto cerebellar atrophy (OPCA: 23 cases), striatonigral degeneration (SND: 7 cases) and Shy-Drager`s syndrome (SDS: 9 cases). OPCA was characterized by atrophy of the entire regions of the brainstem and the cerebellum. SND and SDS tended to show atrophy similar in type but lessin extent to OPCA. The common lesions in MSA were atrophy of the pontine base and cerebellum, and dilation of the fourth ventricle. Atrophy of the pontine base was more dominant in the inferior part than in the superior part, and cerebellar atrophy was more dominant in the superior part than in the inferior part, indicating that degeneration of the pontocerebellar pathway proceeds principally along fibers connecting the inferior part of the pons and the superior part of the cerebellum. Dilation of the fourth ventricle indicated atrophy of the middle cerebellar peduncle. In almost all the cases of OPCA and about a half the cases of SND and SDS, the pontine base and the middle cerebellar peduncle appeared as high signal intensity on T{sub 2} weighted image and as low intensity on T{sub 1}, suggesting degeneration and demyelination. In a few cases of OPCA, the dorsolateral part of the putamen were demonstrated as low signal intensity on T{sub 2} weighted image. (author).

  4. A comparison of non-contrast and contrast-enhanced MRI in the initial stage of Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Harry K.W. [Texas Scottish Rite Hospital for Children, Center of Excellence in Hip Disorders, Dallas, TX (United States); University of Texas Southwestern, Department of Orthopedic Surgery, Dallas, TX (United States); Kaste, Sue [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee School of Health Sciences, Department of Radiology, Memphis, TN (United States); Dempsey, Molly; Wilkes, David [Texas Scottish Rite Hospital for Children, Department of Radiology, Dallas, TX (United States)

    2013-09-15

    A prognostic indicator of outcome for Legg-Calve-Perthes disease (LCP) is needed to guide treatment decisions during the initial stage of the disease (stage 1), before deformity occurs. Radiographic prognosticators are applicable only after fragmentation (stage II). We investigated pre- and postcontrast MRI in depicting stage I femoral head involvement. Thirty children with stage I LCP underwent non-contrast coronal T1 fast spin-echo (FSE) and corresponding postcontrast fat-suppressed T1-weighted fast spin-echo (FSE) sequences to quantify the extent of femoral head involvement. Three pediatric radiologists and one pediatric orthopedic surgeon independently measured central head involvement. Interobserver reliability of percent head involvement using non-contrasted MR images had intraclass correlation coefficient (ICC) of 0.72. Postcontrast MRI improved interobserver reliability (ICC 0.82). Qualitatively, the area of involvement was more clearly visible on contrast-enhanced MRI. A comparison of results obtained by each observer using the two MRI techniques showed no correlation. ICC ranged from -0.08 to 0.03 for each observer. Generally, greater head involvement was depicted by contrast compared with non-contrast MRI (Pearson r = -0.37, P = 0.04). Pre- and postcontrast MRI assess two different components of stage I LCP. However, contrast-enhanced MRI more clearly depicts the area of involvement. (orig.)

  5. Early detection of metastases using whole-body MRI for initial staging and routine follow-up of myxoid liposarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Gorelik, Natalia; Reddy, Santhosh Mauvva Venkatesh; Powell, Thomas I. [McGill University Health Center, Department of Diagnostic Radiology, Montreal, Quebec (Canada); Turcotte, Robert E.; Goulding, Krista [McGill University Health Center, Division of Orthopaedic Surgery, Montreal, Quebec (Canada); Jung, Sungmi [McGill University Health Center, Department of Pathology, Montreal, Quebec (Canada); Alcindor, Thierry [McGill University Health Center, Gerald Bronfman Department of Oncology, Division of Medical Oncology, Montreal, Quebec (Canada)

    2018-03-15

    To define the role of whole-body MRI (WBMRI) for initial staging and routine follow-up of myxoid liposarcoma (MLS). A retrospective review of all the patients with MLS who underwent WBMRI for initial staging and routine follow-up at our institution between October 1, 2006, and September 30, 2016 was performed. Patient demographics, clinical presentation, imaging findings, tumor histology, and occurrence and location of metastatic disease were recorded. Thirty-three patients who underwent a total of 150 WBMRI examinations were included in the study. Nine patients (27%) were diagnosed with metastases between 0 and 60 months (median 10; interquartile range, 7-13) from the diagnosis of the primary tumor. The initial site of metastatic disease was extrapulmonary in all patients. Only two patients developed pulmonary metastases, which were diagnosed by CT chest 9 and 29 months after the diagnosis of extrapulmonary metastases. The first metastasis was diagnosed by WBMRI in seven patients (78%), by thoracic CT in one patient, and by abdominal CT in one patient. Eight of nine patients (89%) were asymptomatic at the time of diagnosis of the metastases. In seven patients (78%), WBMRI demonstrated metastases included within the field of view of, but occult on a contemporaneous CT scan. Our 10-year institutional experience demonstrates that WBMRI facilitates early detection of extrapulmonary MLS metastases before the onset of clinical symptoms and pulmonary metastases. WBMRI also depicts extrapulmonary metastases that are occult on CT scans. The current surveillance strategies are insufficient for screening for extrapulmonary MLS metastases. (orig.)

  6. Characteristic MRI findings in multiple system atrophy: comparison of the three subtypes

    Energy Technology Data Exchange (ETDEWEB)

    Naka, H.; Ohshita, T.; Murata, Y.; Imon, Y.; Mimori, Y.; Nakamura, S. [Department of Internal Medicine, Hiroshima University School of Medicine, Hiroshima (Japan)

    2002-03-01

    We reviewed MRI findings in 29 patients with probable multiple system atrophy (MSA) to see whether there were common and or less common neuroradiological findings in the various clinical subtypes. We divided the patients into three clinical subtypes according to initial and predominant symptoms: 14 with olivopontocerebellar atrophy (OPCA), eight with the Shy-Drager syndrome (SDS) and seven with striatonigral degeneration (SND). The patients showed atrophy of the brain stem and cerebellum, high signal on T2-weighted images of the base of the pons and middle cerebellar peduncles, high and low signal on T2-weighted images of the putamen and atrophy of frontal and parietal lobes. The degree of atrophy of the middle cerebellar peduncle and cerebellum was greater in OPCA patients and a high-signal lateral rim to the putamen more frequent in SND. However, all findings were observed in all subtypes, and the degrees of atrophy of the putamen and pons and the frequency of high signal in the base of the pons were similar in the subtypes. We also found atrophy of the cerebral hemispheres, especially the frontal and parietal lobes, but its degree was not significantly different in the various subtypes. Our findings suggest that, although MSA can be divided clinically into three subtypes, most of the features on MRI are common and overlap in the subtypes, independently of the clinical presentation. (orig.)

  7. WE-EF-BRD-02: Battling Maxwell’s Equations: Physics Challenges and Solutions for Hybrid MRI Systems

    Energy Technology Data Exchange (ETDEWEB)

    Keall, P. [University of Sydney (Australia)

    2015-06-15

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapy from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.

  8. WE-EF-BRD-02: Battling Maxwell’s Equations: Physics Challenges and Solutions for Hybrid MRI Systems

    International Nuclear Information System (INIS)

    Keall, P.

    2015-01-01

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapy from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php

  9. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  10. Characterization of acoustic noise in a neonatal intensive care unit MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Jean A.; Li, Yu; Pratt, Ronald G.; Loew, Wolfgang; Daniels, Barret R.; Giaquinto, Randy O.; Dumoulin, Charles L. [Cincinnati Children' s Hospital Medical Center, Imaging Research Center, Department of Radiology, Cincinnati, OH (United States); Baroch, Kelly A. [Cincinnati Children' s Hospital Medical Center, Division of Audiology, Cincinnati, OH (United States); Merhar, Stephanie L. [Cincinnati Children' s Hospital Medical Center, Division of Neonatology and Pulmonary Biology, Perinatal Institute, Cincinnati, OH (United States); Kline-Fath, Beth M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2014-08-15

    To eliminate the medical risks and logistical challenges of transporting infants from the neonatal intensive care unit (NICU) to the radiology department for magnetic resonance imaging, a small-footprint 1.5-T MRI scanner has been developed for neonatal imaging within the NICU. MRI is known to be noisy, and exposure to excessive acoustic noise has the potential to elicit physiological distress and impact development in the term and preterm infant. To measure and compare the acoustic noise properties of the NICU MRI system against those of a conventional 1.5-T MRI system. We performed sound pressure level measurements in the NICU MRI scanner and in a conventional adult-size whole-body 1.5-T MRI system. Sound pressure level measurements were made for six standard clinical MR imaging protocols. The average sound pressure level value, reported in unweighted (dB) and A-weighted (dBA) decibels for all six imaging pulse sequences, was 73.8 dB and 88 dBA for the NICU scanner, and 87 dB and 98.4 dBA for the conventional MRI scanner. The sound pressure level values measured on the NICU scanner for each of the six MR imaging pulse sequences were consistently and significantly (P = 0.03) lower, with an average difference of 14.2 dB (range 10-21 dB) and 11 dBA (range 5-18 dBA). The sound pressure level frequency response of the two MR systems showed a similar harmonic structure above 200 Hz for all imaging sequences. The amplitude, however, was appreciably lower for the NICU scanner, by as much as 30 dB, for frequencies below 200 Hz. The NICU MRI system is quieter than conventional MRI scanners, improving safety for the neonate and facilitating siting of the unit within the NICU. (orig.)

  11. Characterization of acoustic noise in a neonatal intensive care unit MRI system

    International Nuclear Information System (INIS)

    Tkach, Jean A.; Li, Yu; Pratt, Ronald G.; Loew, Wolfgang; Daniels, Barret R.; Giaquinto, Randy O.; Dumoulin, Charles L.; Baroch, Kelly A.; Merhar, Stephanie L.; Kline-Fath, Beth M.

    2014-01-01

    To eliminate the medical risks and logistical challenges of transporting infants from the neonatal intensive care unit (NICU) to the radiology department for magnetic resonance imaging, a small-footprint 1.5-T MRI scanner has been developed for neonatal imaging within the NICU. MRI is known to be noisy, and exposure to excessive acoustic noise has the potential to elicit physiological distress and impact development in the term and preterm infant. To measure and compare the acoustic noise properties of the NICU MRI system against those of a conventional 1.5-T MRI system. We performed sound pressure level measurements in the NICU MRI scanner and in a conventional adult-size whole-body 1.5-T MRI system. Sound pressure level measurements were made for six standard clinical MR imaging protocols. The average sound pressure level value, reported in unweighted (dB) and A-weighted (dBA) decibels for all six imaging pulse sequences, was 73.8 dB and 88 dBA for the NICU scanner, and 87 dB and 98.4 dBA for the conventional MRI scanner. The sound pressure level values measured on the NICU scanner for each of the six MR imaging pulse sequences were consistently and significantly (P = 0.03) lower, with an average difference of 14.2 dB (range 10-21 dB) and 11 dBA (range 5-18 dBA). The sound pressure level frequency response of the two MR systems showed a similar harmonic structure above 200 Hz for all imaging sequences. The amplitude, however, was appreciably lower for the NICU scanner, by as much as 30 dB, for frequencies below 200 Hz. The NICU MRI system is quieter than conventional MRI scanners, improving safety for the neonate and facilitating siting of the unit within the NICU. (orig.)

  12. [Mechanical Shimming Method and Implementation for Permanent Magnet of MRI System].

    Science.gov (United States)

    Xue, Tingqiang; Chen, Jinjun

    2015-03-01

    A mechanical shimming method and device for permanent magnet of MRI system has been developed to meet its stringent homogeneity requirement without time-consuming passive shimming on site, installation and adjustment efficiency has been increased.

  13. 4 Tesla Whole Body MRI MRSI System for Investigation of Neurodegenerative Diseases

    National Research Council Canada - National Science Library

    Weiner, Michael W

    2004-01-01

    The overall long-term goal of imaging research to be performed with this 4 Tesla Siemens/Bruker MRI system is the development of improved diagnostic methods for accurate detection of neurodegenerative...

  14. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    Science.gov (United States)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  15. MRI system scoring for differentiation of malignant versus benign stricture of the common bile duct

    Directory of Open Access Journals (Sweden)

    Savastano S

    2016-11-01

    Full Text Available The purpose of this study was to evaluate the ability of magnetic resonance imaging (MRI to differentiate between malignant and benign strictures of the common bile duct by using a scoring system. MRI scans of 34 patients with indeterminate biliary stricture on prior imaging were reviewed; non-enhanced MRI, magnetic resonance cholangiopancreatography (MRCP, diffusion weighted imaging, and contrast-enhanced MRIs were considered for analysis. Ten radiologic findings were significant for malignancy: luminal irregularity, post-contrast conspicuity, high signal intensity on diffusion weighted MRI, luminal stenosis asymmetry, T2-weighted MRI signal intensity, indistinct outer border, abrupt stenosis, bile duct dilatation ≥ 12.5 mm, stenosis length ≥ 10.5 mm, and wall thickness ≥ 4.5 mm. Since none of these findings was pathognomonic for malignancy, a simple system scoring based on statistically significant findings was developed, where each of the above findings counts for one point. A score of 6 or higher was found only in patients with a malignant stricture of the common bile duct; 70% of patients with a benign stenosis had a score of 1, or 2, and all patients with benign lesions had scores of less than 5. This MRI scoring system can assist in the differential diagnosis of common bile duct stricture with high accuracy; to be widely applicable, the MRI score needs to be validated in a prospective patient population.

  16. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms

    International Nuclear Information System (INIS)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-01-01

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards. (paper)

  17. 3 Tesla MRI of patients with a vagus nerve stimulator: initial experience using a T/R head coil under controlled conditions.

    Science.gov (United States)

    Gorny, Krzysztof R; Bernstein, Matt A; Watson, Robert E

    2010-02-01

    To assess safety of clinical MRI of the head in patients with implanted model 100, 102, and 103 vagus nerve stimulation (VNS) Therapy Systems (Cyberonics, Inc., Houston, TX) in 3.0 Tesla MRI (GE Healthcare, Milwaukee, WI). The distributions of the radiofrequency B(1) (+)-field produced by the clinically used transmit/receive (T/R) head coil (Advanced Imaging Research Incorporated, Cleveland, OH) and body coil were measured in a head and shoulders phantom. These measurements were supplemented by temperature measurements on the lead tips and the implantable pulse generator (IPG) of the VNS devices in a head and torso phantom with the same two coils. Clinical 3T MRI head scans were then acquired under highly controlled conditions in a series of 17 patients implanted with VNS. Phantom studies showed only weak B(1) (+) fields at the location of the VNS IPG and leads for MRI scans using the T/R head coil. The MRI-related heating on a VNS scanned in vitro at 3T was also found to be minimal (0.4-0.8 degrees C at the leads, negligible at the IPG). The patient MRI examinations were completed successfully without any adverse incidents. No patient reported any heating, discomfort, or any other unusual sensation. Safe clinical MRI head scanning of patients with implanted VNS is shown to be feasible on a GE Signa Excite 3T MRI system using one specific T/R head coil. These results apply to this particular MRI system configuration. Extrapolation or generalization of these results to more general or less controlled imaging situations without supporting data of safety is highly discouraged.

  18. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    OpenAIRE

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian...

  19. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [{sup 18}F]-fluoroethyltyrosine (FET) PET/MRI: feasibility, agreement and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Otto M.; Hansen, Adam E.; Law, Ian [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Clinical Physiology Nuclear Medicine and PET, Copenhagen (Denmark); Larsen, Vibeke A. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Radiology, Copenhagen (Denmark); Muhic, Aida; Poulsen, Hans S. [Copenhagen University Hospital Rigshospitalet Blegdamsvej, Department of Oncology, Copenhagen (Denmark); Larsson, Henrik B.W. [Copenhagen University Hospital Rigshospitalet Glostrup, Functional Imaging Unit, Department of Clinical Physiology Nuclear Medicine and PET, Glostrup (Denmark)

    2016-01-15

    Both [{sup 18}F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens mMR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBR{sub max}) and BV (rBV{sub max}), and Dice coefficients were calculated to assess the quantitative and spatial congruence in the tumour volumes determined by FET PET, BV MRI and contrast-enhanced MRI. FET volume and TBR{sub max} were higher in BV-positive than in BV-negative scans, and both VOL{sub BV} and rBV{sub max} were higher in FET-positive than in FET-negative scans. TBR{sub max} and rBV{sub max} were positively correlated (R{sup 2} = 0.59, p < 0.001). FET and BV positivity were in agreement in only 26 of the 32 patients and in 42 of 63 lesions, and spatial congruence in the tumour volumes as assessed by the Dice coefficients was generally poor with median Dice coefficients exceeding 0.1 in less than half the patients positive on at least one modality for any pair of modalities. In 56 % of the patients susceptibility artefacts in DSC BV maps overlapped the tumour on MRI. The study demonstrated that although tumour volumes determined by BV MRI and FET PET were quantitatively correlated, their spatial congruence in a mixed population of treated glioma patients was generally poor, and the modalities did not provide the same information in this population of patients. Combined

  20. [Positron emission tomography combined with computed tomography in the initial evaluation and response assessment in primary central nervous system lymphoma].

    Science.gov (United States)

    Mercadal, Santiago; Cortés-Romera, Montserrat; Vélez, Patricia; Climent, Fina; Gámez, Cristina; González-Barca, Eva

    2015-06-08

    To evaluate the role of positron emission tomography combined with computed tomography (PET-CT) in the initial evaluation and response assessment in primary central nervous system lymphoma (PCNSL). Fourteen patients (8 males) with a median age 59.5 years diagnosed of PCNSL. A brain PET-CT and magnetic resonance imaging (MRI) were performed in the initial evaluation. In 7 patients a PET-CT after treatment was performed. PET-CT showed at diagnosis 31 hypermetabolic focuses and MRI showed 47 lesions, with a good grade of concordance between both (k = 0.61; P = .005). In the response assessment, correlation between both techniques was good, and PET-CT was helpful in the appreciation of residual MRI lesions. Overall survival at 2 years of negative vs. positive PET-CT at the end of treatment was 100 vs. 37.5%, respectively (P = .045). PET-CT can be useful in the initial evaluation of PCNSL, and especially in the assessment of response. Despite the fact that PET-CT detects less small lesions than MRI, a good correlation between MRI and PET-CT was observed. It is effective in the evaluation of residual lesions. Prospective studies are needed to confirm their possible prognostic value. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  1. 30 CFR 56.6501 - Nonelectric initiation systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Nonelectric initiation systems. 56.6501 Section... Nonelectric Blasting § 56.6501 Nonelectric initiation systems. (a) When the nonelectric initiation system uses... for uninterrupted propagation; (2) Factory-made units shall be used as assembled and shall not be cut...

  2. Desmoid fibromatosis: MRI features of response to systemic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, Pooja J.; Subhawong, Ty K. [University of Miami Miller School of Medicine/Jackson Memorial Hospital, Department of Radiology, Miami, FL (United States); Del Moral, Spencer; Wilky, Breelyn A.; Trent, Jonathan C. [University of Miami Miller School of Medicine/Sylvester Comprehensive Cancer Center, Division of Hematology/Oncology, Department of Medicine, Miami, FL (United States); Cohen, Jonathan [Oncology and Radiation Associates, Miami, FL (United States); Rosenberg, Andrew E. [University of Miami Miller School of Medicine, Department of Pathology, Miami, FL (United States); Temple, H.T. [Center for Orthopedic Innovations, Miami, FL (United States)

    2016-10-15

    Imaging criteria for measuring the response of desmoid fibromatosis to systemic therapy are not well established. We evaluated a series of patients with desmoids who underwent systemic therapy to document magnetic resonance imaging (MRI) features associated with a positive clinical response. This Institutional Review Board-approved retrospective study included 23 patients (mean age 40.5) with 29 extra-abdominal tumors. Therapeutic regimens included cytotoxic chemotherapy (n = 19), targeted therapy (n = 3), and nonsteroid anti-inflammatory drugs (NSAIDS; n = 1). Clinical effects were categorized as progressive disease, stable, or partial response. Maximum tumor dimension (D{sub max}), approximate tumor volume (V{sub Tumor}), and quantitative tumor T2 hyperintensity and contrast enhancement (relative to muscle) for pre- and post-treatment MRIs were compared. Three lesions progressed, 5 lesions were stable, whereas 21 showed a clinical response. D{sub max} decreased more in responders (mean -11.0 %) than in stable/progressive lesions (mean -3.6 and 0 % respectively, p = 0.28, ANOVA); by Response Evaluation Criteria in Solid Tumors (RECIST 1.1) 27 out of 29 lesions were ''stable,'' including the 3 progressive lesions. In responders, V{sub Tumor} change averaged -29.4 %, but -19.2 % and +32.5 % in stable and progressive lesions respectively (p = 0.002, ANOVA); by 3D criteria 14 out of 29 lesions showed a partial response. T2 hyperintensity decreased by 50-54 % in partial response/stable disease, but only by 10 % in progressive lesions (p = 0.049, t test). Changes in contrast enhancement ranged from -23 % to 0 %, but were not statistically significant among response groups (p = 0.37). Change in T2 hyperintensity showed a positive correlation with volumetric change (r = 0.40). Decreases in volume and T2 hyperintensity reflect the positive response of desmoid fibromatosis to systemic therapy; RECIST 1.1 criteria are not sensitive to clinically

  3. Primary Central Nervous System Lymphoma: Incorporating MRI in the Planning of Treatment Strategies

    International Nuclear Information System (INIS)

    Eloraby, A.; Zaki, I.

    2001-01-01

    Primary lymphoma of the central nervous system is becoming increasingly encountered secondary to the acquired immune-deficiency disorders. MRI is rapidly evolving diagnostic tool in the management of the lymphomatous CNS primary infiltrates. Methods and materials: 40 patients of the National Cancer Institute of Cairo University were studied by medium and high power MRI machines before and after intra-venous contrast enhancement. Results: The cerebral lesions exhibited specific diagnostic criteria regarding the anatomical configuration, signal pattern, peri-focal oedema and response to steroids, such manifestations made. Conclusion: MRI a highly reliable tool in the management of the disease. The work proved that spinal cord primary lymphoma is a rare entity

  4. Recommendations for secure initialization routines in operating systems

    OpenAIRE

    Dodge, Catherine A.

    2004-01-01

    Approved for public release; distribution in unlimited. While a necessity of all operating systems, the code that initializes a system can be notoriously difficult to understand. This thesis explores the most common architectures used for bringing an operating system to its initial state, once the operating system gains control from the boot loader. Specifically, the ways in which the OpenBSD and Linux operating systems handle initialization are dissected. With this understanding, a set ...

  5. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  6. Experimental MRI-SPECT insert system with Hybrid Semiconductor detectors Timepix for MR animal scanner Bruker 47/20

    Science.gov (United States)

    Zajicek, J.; Burian, M.; Soukup, P.; Novak, V.; Macko, M.; Jakubek, J.

    2017-01-01

    Multimodal medical imaging based on Magnetic Resonance is mainly combinated with one of the scintigraphic method like PET or SPECT. These methods provide functional information whereas magnetic resonance imaging provides high spatial resolution of anatomical information or complementary functional information. Fusion of imaging modalities allows researchers to obtain complimentary information in a single measurement. The combination of MRI with SPECT is still relatively new and challenging in many ways. The main complication of using SPECT in MRI systems is the presence of a high magnetic field therefore (ferro)magnetic materials have to be eliminated. Furthermore the application of radiofrequency fields within the MR gantry does not allow for the use of conductive structures such as the common heavy metal collimators. This work presents design and construction of an experimental MRI-SPECT insert system and its initial tests. This unique insert system consists of an MR-compatible SPECT setup with CdTe pixelated sensors Timepix tungsten collimators and a radiofrequency coil. Measurements were performed on a gelatine and tissue phantom with an embedded radioisotopic source (57Co 122 keV γ ray) inside the RF coil by the Bruker BioSpec 47/20 (4.7 T) MR animal scanner. The project was performed in the framework of the Medipix Collaboration.

  7. Clinical evaluation of shoulder kinematic MRI using an open-type system

    International Nuclear Information System (INIS)

    Ohno, Seiichiro; Togami, Izumi; Sasai, Nobuya

    2000-01-01

    Previous studies on kinematic MRI of the shoulder using cylindrical-type MRI systems were limited to internal or external rotation. The open-type MRI system enables kinematic MRI to be carried out for the abductive position, and is expected to permit evaluation of the superior and inferior glenoid labrum. It is important to evaluate the superior and inferior glenoid labrum in cases of sports injuries (baseball, tennis, etc.). We evaluated the superior and inferior glenoid labrum for abductive motion in asymptomatic healthy volunteers as a preliminary study. As the abduction angle increased, the superior labrum moved into the joint space. Its shape changed from round or triangular to crescent (p<0.0001), and there was increased signal for larger abduction angles (p<0.0001). On the other hand, the shape of the inferior labrum tended to change from crescent to triangular or round (p<0.0001). Increased signal was seen in the inferior labrum on about half the shoulders (N.P.). This did not change as the abduction angle increased. Our results define normal patterns for the superior and inferior glenoid labrum on abductive kinematic MRI in healthy volunteers. Abductive kinematic studies using an open-type MRI system, which permits dynamic evaluation of the superior and inferior glenoid labrum, are expected to be useful for various patients with sports injuries. (author)

  8. Initial experience with intravenous pentobarbital sedation for children undergoing MRI at a tertiary care pediatric hospital: the learning curve

    International Nuclear Information System (INIS)

    Greenberg, S.B.; Adams, R.C.; Aspinall, C.L.

    2000-01-01

    Objective. Our purpose is to describe the initial experience with intravenous pentobarbital sedation in children undergoing MRI at a tertiary pediatric hospital to identify errors associated with inexperience. Subjects and methods. The study included the first 100 children sedated with intravenous pentobarbital prior to magnetic resonance examination at a tertiary pediatric hospital. The protocol included a maximum dose of 6 mg/kg administered in three divided doses with the total dose not to exceed 200 mg. Flow sheets documenting vital signs, administered drug doses, and adverse reactions were maintained contemporaneous to sedation. Results. Sedation was successful in 92 children. Of the eight children who failed sedation, three were at least 12 years old and three weighed more than 50 kg. χ 2 tests identified significantly greater failure rates in children older than 11 years or weight greater than 50 kg. Two children had prolonged sedation after the maximum suggested dose was exceeded. Conclusions. The success rate was good, but could have been improved by restricting the use of pentobarbital to children less than 12 years of age and weighing less than 50 kg. Radiologists inexperienced with intravenous sedation should strictly observe the maximum suggested dose of pentobarbital to prevent prolonged sedation. (orig.)

  9. Binary Systems and the Initial Mass Function

    Science.gov (United States)

    Malkov, O. Yu.

    2017-07-01

    In the present paper we discuss advantages and disadvantages of binary stars, which are important for star formation history determination. We show that to make definite conclusions of the initial mass function shape, it is necessary to study binary population well enough to correct the luminosity function for unresolved binaries; to construct the mass-luminosity relation based on wide binaries data, and to separate observational mass functions of primaries, of secondaries, and of unresolved binaries.

  10. Role of pharmacokinetic parameters derived with high temporal resolution DCE MRI using simultaneous PET/MRI system in breast cancer: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Jena, Amarnath, E-mail: drjena2002@gmail.com [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Taneja, Sangeeta; Singh, Aru; Negi, Pradeep; Mehta, Shashi Bhushan [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Sarin, Ramesh [Department of Surgical Oncology, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India)

    2017-01-15

    Highlights: • Simultaneous PET/MRI (with 3T MRI in the core) for quantitative pharmacokinetics. • Diagnostic accuracy of pharmacokinetic parameters like K{sup trans}, K{sub ep} and v{sub e} acquired through this system. • Incorporating high temporal resolution sequence with short acquisition time of 60 s within the routine DCE MRI in a simultaneous PET/MRI system. - Abstract: Purpose: To evaluate the reliability of pharmacokinetic parameters like K{sup trans}, Kep and v{sub e} derived through DCE MRI breast protocol using 3 T Simultaneous PET/MRI (3 Tesla Positron Emission Tomography/Magnetic Resonance Imaging) system in distinguishing benign and malignant lesions. Materials and methods: High temporal resolution DCE (Dynamic Contrast Enhancement) MRI performed as routine breast MRI for diagnosis or as a part of PET/MRI for cancer staging using a 3 T simultaneous PET/MRI system in 98 women having 109 breast lesions were analyzed for calculation of pharmacokinetic parameters (K{sup trans}, v{sub e}, and Kep) at 60 s time point using an in-house developed computation scheme. Results: Receiver operating characteristic (ROC) curve analysis revealed a cut off value for K{sup trans}, Kep, v{sub e} as 0.50, 2.59, 0.15 respectively which reliably distinguished benign and malignant breast lesions. Data analysis revealed an overall accuracy of 94.50%, 79.82% and 87.16% for K{sup trans}, Kep, v{sub e} respectively. Introduction of native T1 normalization with an externally placed phantom showed a higher accuracy (94.50%) than without native T1 normalization (93.50%) with an increase in specificity of 87% vs 84%. Conclusion: Overall the results indicate that reliable measurement of pharmacokinetic parameters with reduced acquisition time is feasible in a 3TMRI embedded PET/MRI system with reasonable accuracy and application may be extended to exploit the potential of simultaneous PET/MRI in further work on breast cancer.

  11. 18F-FDG PET and MRS of the early stages of subacute sclerosing panencephalitis in a child with a normal initial MRI

    International Nuclear Information System (INIS)

    Seo, Yeong-Seon; Jung, Da-Eun; Kim, Ho-Sung

    2010-01-01

    In subacute sclerosing panencephalitis (SSPE), conventional MRI findings have been reported. However, in the early clinical stages, imaging studies can appear normal. Moreover, with no history of infant measles infection, the diagnosis of SSPE can only be arrived at after extensive investigation that must eliminate a number of neurodegenerative diseases. We report here on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET) and magnetic resonance spectroscopy (MRS) findings in a 14-year-old girl with a normal initial MRI who had not contracted measles. Although 18 F-FDG PET and MRS are not specific or diagnostic for SSPE, these techniques can demonstrate substantial metabolic impairments when MRI findings show no obvious abnormalities, as is often the case in the early stages of this disease. (orig.)

  12. {sup 18}F-FDG PET and MRS of the early stages of subacute sclerosing panencephalitis in a child with a normal initial MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Yeong-Seon; Jung, Da-Eun [Ajou University School of Medicine, Department of Pediatrics, Suwon, Kyungki-do (Korea, Republic of); Kim, Ho-Sung [Ajou University School of Medicine, Department of Radiology, Suwon, Kyungki-do (Korea, Republic of)

    2010-11-15

    In subacute sclerosing panencephalitis (SSPE), conventional MRI findings have been reported. However, in the early clinical stages, imaging studies can appear normal. Moreover, with no history of infant measles infection, the diagnosis of SSPE can only be arrived at after extensive investigation that must eliminate a number of neurodegenerative diseases. We report here on {sup 18} F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) and magnetic resonance spectroscopy (MRS) findings in a 14-year-old girl with a normal initial MRI who had not contracted measles. Although {sup 18} F-FDG PET and MRS are not specific or diagnostic for SSPE, these techniques can demonstrate substantial metabolic impairments when MRI findings show no obvious abnormalities, as is often the case in the early stages of this disease. (orig.)

  13. Task-specific feature extraction and classification of fMRI volumes using a deep neural network initialized with a deep belief network: Evaluation using sensorimotor tasks.

    Science.gov (United States)

    Jang, Hojin; Plis, Sergey M; Calhoun, Vince D; Lee, Jong-Hwan

    2017-01-15

    Feedforward deep neural networks (DNNs), artificial neural networks with multiple hidden layers, have recently demonstrated a record-breaking performance in multiple areas of applications in computer vision and speech processing. Following the success, DNNs have been applied to neuroimaging modalities including functional/structural magnetic resonance imaging (MRI) and positron-emission tomography data. However, no study has explicitly applied DNNs to 3D whole-brain fMRI volumes and thereby extracted hidden volumetric representations of fMRI that are discriminative for a task performed as the fMRI volume was acquired. Our study applied fully connected feedforward DNN to fMRI volumes collected in four sensorimotor tasks (i.e., left-hand clenching, right-hand clenching, auditory attention, and visual stimulus) undertaken by 12 healthy participants. Using a leave-one-subject-out cross-validation scheme, a restricted Boltzmann machine-based deep belief network was pretrained and used to initialize weights of the DNN. The pretrained DNN was fine-tuned while systematically controlling weight-sparsity levels across hidden layers. Optimal weight-sparsity levels were determined from a minimum validation error rate of fMRI volume classification. Minimum error rates (mean±standard deviation; %) of 6.9 (±3.8) were obtained from the three-layer DNN with the sparsest condition of weights across the three hidden layers. These error rates were even lower than the error rates from the single-layer network (9.4±4.6) and the two-layer network (7.4±4.1). The estimated DNN weights showed spatial patterns that are remarkably task-specific, particularly in the higher layers. The output values of the third hidden layer represented distinct patterns/codes of the 3D whole-brain fMRI volume and encoded the information of the tasks as evaluated from representational similarity analysis. Our reported findings show the ability of the DNN to classify a single fMRI volume based on the

  14. Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT--Initial Results.

    Science.gov (United States)

    Zeimpekis, Konstantinos G; Barbosa, Felipe; Hüllner, Martin; ter Voert, Edwin; Davison, Helen; Veit-Haibach, Patrick; Delso, Gaspar

    2015-10-01

    The purpose of this study was to compare only the performance of the PET component between a TOF-PET/CT (henceforth noted as PET/CT) scanner and an integrated TOF-PET/MRI (henceforth noted as PET/MRI) scanner concerning image quality parameters and quantification in terms of standardized uptake value (SUV) as a function of acquisition time (a surrogate of dose). The CT and MR image quality were not assessed, and that is beyond the scope of this study. Five brain and five whole-body patients were included in the study. The PET/CT scan was used as a reference and the PET/MRI acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of the emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts, and noise were evaluated. SUV measurements were taken in the liver and in the white matter to compare quantification. Quantitative evaluation showed strong correlation between PET/CT and PET/MRI brain SUVs. Liver correlation was good, however, with lower uptake estimation in PET/MRI, partially justified by bio-redistribution. The clinical evaluation showed that PET/MRI offers higher image quality and sharpness with lower levels of noise and artifacts compared to PET/CT with reduced acquisition times for whole-body scans while for brain scans there is no significant difference. The TOF-PET/MRI showed higher image quality compared to TOF-PET/CT as tested with reduced imaging times. However, this result accounts mainly for body imaging, while no significant differences were found in brain imaging.

  15. A validated clinical MRI injury scoring system in neonatal hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, Shamik B.; Vesoulis, Zachary A.; Rao, Rakesh; Liao, Steve M.; Mathur, Amit M. [Washington University School of Medicine, Division of Newborn Medicine, Edward Mallinckrodt Department of Pediatrics, St. Louis, MO (United States); Shimony, Joshua S.; McKinstry, Robert C. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States)

    2017-10-15

    Deep nuclear gray matter injury in neonatal hypoxic-ischemic encephalopathy (HIE) is associated with worse neurodevelopmental outcomes. We previously published a qualitative MRI injury scoring system utilizing serial T1-weighted, T2-weighted and diffusion-weighted imaging (DWI), weighted for deep nuclear gray matter injury. To establish the validity of the MRI scoring system with neurodevelopmental outcome at 18-24 months. MRI scans from neonates with moderate to severe HIE treated with therapeutic hypothermia were evaluated. Signal abnormality was scored on T1-weighted, T2-weighted and DWI sequences and assessed using an established system in five regions: (a) subcortical: caudate nucleus, globus pallidus and putamen, thalamus and the posterior limb of the internal capsule; (b) white matter; (c) cortex, (d) cerebellum and (e) brainstem. MRI injury was graded as none, mild, moderate or severe. Inter-rater reliability was tested on a subset of scans by two independent and blinded neuroradiologists. Surviving infants underwent the Bayley Scales of Infant and Toddler Development-III (Bayley-III) at 18-24 months. Data were analyzed using univariate and multivariate linear and logistic regression. Fifty-seven eligible neonates underwent at least one MRI scan in the first 2 weeks of life. Mean postnatal age at scan 1 was 4±2 days in 50/57 (88%) neonates and 48/54 (89%) surviving infants underwent scan 2 at 10±2 days. In 54/57 (95%) survivors, higher MRI injury grades were significantly associated with worse outcomes in the cognitive, motor and language domains of the Bayley-III. A qualitative MRI injury scoring system weighted for deep nuclear gray matter injury is a significant predictor of neurodevelopmental outcome at 18-24 months in neonates with HIE. (orig.)

  16. A validated clinical MRI injury scoring system in neonatal hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Trivedi, Shamik B.; Vesoulis, Zachary A.; Rao, Rakesh; Liao, Steve M.; Mathur, Amit M.; Shimony, Joshua S.; McKinstry, Robert C.

    2017-01-01

    Deep nuclear gray matter injury in neonatal hypoxic-ischemic encephalopathy (HIE) is associated with worse neurodevelopmental outcomes. We previously published a qualitative MRI injury scoring system utilizing serial T1-weighted, T2-weighted and diffusion-weighted imaging (DWI), weighted for deep nuclear gray matter injury. To establish the validity of the MRI scoring system with neurodevelopmental outcome at 18-24 months. MRI scans from neonates with moderate to severe HIE treated with therapeutic hypothermia were evaluated. Signal abnormality was scored on T1-weighted, T2-weighted and DWI sequences and assessed using an established system in five regions: (a) subcortical: caudate nucleus, globus pallidus and putamen, thalamus and the posterior limb of the internal capsule; (b) white matter; (c) cortex, (d) cerebellum and (e) brainstem. MRI injury was graded as none, mild, moderate or severe. Inter-rater reliability was tested on a subset of scans by two independent and blinded neuroradiologists. Surviving infants underwent the Bayley Scales of Infant and Toddler Development-III (Bayley-III) at 18-24 months. Data were analyzed using univariate and multivariate linear and logistic regression. Fifty-seven eligible neonates underwent at least one MRI scan in the first 2 weeks of life. Mean postnatal age at scan 1 was 4±2 days in 50/57 (88%) neonates and 48/54 (89%) surviving infants underwent scan 2 at 10±2 days. In 54/57 (95%) survivors, higher MRI injury grades were significantly associated with worse outcomes in the cognitive, motor and language domains of the Bayley-III. A qualitative MRI injury scoring system weighted for deep nuclear gray matter injury is a significant predictor of neurodevelopmental outcome at 18-24 months in neonates with HIE. (orig.)

  17. Initial performance of upgraded Tevatron cryogenic systems

    International Nuclear Information System (INIS)

    Norris, B.L.

    1996-09-01

    Fermilab began operating a re-designed satellite refrigerator systems in November 1993. Upgrades were installed to operate the Tevatron at a magnet temperature of 3.5 K, approximately 1K lower than the original design. Refrigerator upgrades included new valve boxes, larger reciprocating expanders, the installation of cold vapor compressors, new sub-atmospheric instrumentation and an entirely new distributed controls system. Cryogenic system reliability data for Colliding Physics Run 1B is presented emphasizing a failure analysis for each aspect of the upgrade. Comparison to data for Colliding Physics Run 1A (previous to upgrade) is presented to show the impact of a major system overhaul. New operational problems and their solutions are presented in detail

  18. CT and MRI analysis of central nervous system Rosai-Dorfman disease

    International Nuclear Information System (INIS)

    Zhang Jiatang; Lang Senyang; Pu Chuanqiang; Zhu Ruyuan; Wang Dianjun

    2008-01-01

    Objective: To study the CT and MRI imaging features of central nervous system Rosai-Dorfman disease and to enhance knowledge and differential diagnostic ability for central nervous system Rosai-Doffman disease. Methods: The CT and MRI imaging appearances in 4 cases of pathologically proven Rosai-Dorfman disease were retrospectively evaluated and the literature of central nervous system Rosai- Dorfman disease were reviewed. Results: Two cases had cranial CT scans, 4 cases had cranial MRI scans. On CT scans, cerebral edema was demonstrated in one case and the other case was normal. MRI scans showed the lesions were solitary in saddle area in 3 cases, and multiple in anterior cranial fossa in 1 case. The lesions exhibited iso- to hypointensity on both T 1 WI and T 2 WI images. Following intravenous injection of contrast medium, ring-like enhancement was seen in 2 cases and homogeneous enhancement in 1 case. Nodular enhancement was seen in the case of multiple lesions in the anterior cranial fossa. All lesions were dural-based. Conclusions: In patients with fever, headache, elevation of the erythrocyte sedimentation rate (ESR) and a polyclonal increase in γ-globulins, the possibility of central nervous system Rosai-Dorfman disease should be considered when single or multiple dural-based mass lesions, especially in sellar region, were identified by CT and MRI. (authors)

  19. Evaluation of Brain and Cervical MRI Abnormality Rates in Patients With Systemic Lupus Erythematosus With or Without Neurological Manifestations

    International Nuclear Information System (INIS)

    Harirchian, Mohammad Hossein; Saberi, Hazhir; Najafizadeh, Seyed Reza; Hashemi, Seyed Ali

    2011-01-01

    Central nervous system (CNS) involvement has been observed in 14-80% of patients with systemic lupus erythematosus (SLE). Magnetic resonance imaging (MRI) is an appropriate method for evaluating CNS involvement in these patients. Clinical manifestations and MRI findings of CNS lupus should be differentiated from other mimicking diseases such as multiple sclerosis (MS). The aim of this study was to evaluate the prevalence and extent of brain and cervical cord MRI lesions of lupus patients. The relationship between neurological signs and symptoms and MRI findings were evaluated as well. Fifty SLE patients who had been referred to the rheumatology clinic of our hospital within 2009 were included in a cross sectional study. All patients fulfilled the revised 1981 American College of Rheumatology (ACR) criteria for SLE. We evaluated the neurological signs and symptoms and brain and cervical MRI findings in these patients. Forty-one patients (82%) were female and nine (18%) were male. The mean age was 30.1 ± 9.3 years. Twenty eight (56%) patients had an abnormal brain MRI. No one showed any abnormality in the cervical MRI. The lesions in 20 patients were similar to demyelinative plaques. Seventeen patients with abnormal brain MRI were neurologically asymptomatic. There was only a significant relationship between neurological motor manifestations and brain MRI abnormal findings. Unlike the brain, cervical MRI abnormality and especially asymptomatic cord involvement in MRI is quite rare in SLE patients. This finding may be helpful to differentiate SLE from other CNS disorders such as MS

  20. Magnetic field simulation and shimming analysis of 3.0T superconducting MRI system

    Science.gov (United States)

    Yue, Z. K.; Liu, Z. Z.; Tang, G. S.; Zhang, X. C.; Duan, L. J.; Liu, W. C.

    2018-04-01

    3.0T superconducting magnetic resonance imaging (MRI) system has become the mainstream of modern clinical MRI system because of its high field intensity and high degree of uniformity and stability. It has broad prospects in scientific research and other fields. We analyze the principle of magnet designing in this paper. We also perform the magnetic field simulation and shimming analysis of the first 3.0T/850 superconducting MRI system in the world using the Ansoft Maxwell simulation software. We guide the production and optimization of the prototype based on the results of simulation analysis. Thus the magnetic field strength, magnetic field uniformity and magnetic field stability of the prototype is guided to achieve the expected target.

  1. RHIC Beam Loss Monitor System Initial Operation

    International Nuclear Information System (INIS)

    Witkover, R. L.; Michnoff, R. J.; Geller, J. M.

    1999-01-01

    The RHIC Beam Loss Monitor (BLM) System is designed to prevent beam loss quenching of the superconducting magnets, and acquire loss data. Four hundred ion chambers are located around the rings to detect losses. The required 8-decade range in signal current is compressed using an RC pre-integrator ahead of a low current amplifier. A beam abort may be triggered if fast or slow losses exceed programmable threshold levels. A micro-controller based VME module sets references and gains and reads trip status for up to 64 channels. Results obtained with the detectors in the RHIC Sextant Test and the prototype electronics in the AGS-to-RHIC (AtR) transfer line are presented along with the present status of the system

  2. 18F-FDOPA PET/MRI fusion in patients with primary/recurrent gliomas: Initial experience

    International Nuclear Information System (INIS)

    Ledezma, Carlos J.; Chen, Wei; Sai, Victor; Freitas, Bonnie; Cloughesy, Tim; Czernin, Johannes; Pope, Whitney

    2009-01-01

    Background and purpose: 18 F-FDOPA PET demonstrates higher sensitivity and specificity for gliomas than traditional [ 18 F] FDG PET imaging. However, PET provides limited anatomic localization. The purpose of this study was to determine whether 18 F-FDOPA PET/MRI fusion can provide precise anatomic localization of abnormal tracer uptake and how this activity corresponds to MR signal abnormality. Methods: Two groups of patients were analyzed. Group I consisted of 21 patients who underwent 18 F-FDOPA PET and MRI followed by craniotomy for tumor resection. Group II consisted of 70 patients with a pathological diagnosis of glioma that had 18 F-FDOPA PET and MRI but lacked additional pathologic follow-up. Fused 18 F-FDOPA PET and MRI images were analyzed for concordance and correlated with histopathologic data. Results: Fusion technology facilitated precise anatomical localization of 18 F-FDOPA activity. In group I, all 21 cases showed pathology-confirmed tumor. Of these, 18 F-FDOPA scans were positive in 9/10 (90%) previously unresected tumors, and 11/11 (100%) of recurrent tumors. Of the 70 patients in group II, concordance between MRI and 18 F-FDOPA was found in 49/54 (90.1%) of patients with sufficient follow-up; in the remaining 16 patients concordance could not be determined due to lack of follow-up. 18 F-FDOPA labeling was comparable in both high- and low-grade gliomas and identified both enhancing and non-enhancing tumor equally well. In some cases, 18 F-FDOPA activity preceded tumor detection on MRI. Conclusion: 18 F-FDOPA PET/MRI fusion provides precise anatomic localization of tracer uptake and labels enhancing and non-enhancing tumor well. In a small minority of cases, 18 F-FDOPA activity may identify tumor not visible on MRI.

  3. PET Imaging of Tau Pathology and Relationship to Amyloid, Longitudinal MRI, and Cognitive Change in Down Syndrome: Results from the Down Syndrome Biomarker Initiative (DSBI).

    Science.gov (United States)

    Rafii, Michael S; Lukic, Ana S; Andrews, Randolph D; Brewer, James; Rissman, Robert A; Strother, Stephen C; Wernick, Miles N; Pennington, Craig; Mobley, William C; Ness, Seth; Matthews, Dawn C

    2017-01-01

    Adults with Down syndrome (DS) represent an enriched population for the development of Alzheimer's disease (AD), which could aid the study of therapeutic interventions, and in turn, could benefit from discoveries made in other AD populations. 1) Understand the relationship between tau pathology and age, amyloid deposition, neurodegeneration (MRI and FDG PET), and cognitive and functional performance; 2) detect and differentiate AD-specific changes from DS-specific brain changes in longitudinal MRI. Twelve non-demented adults, ages 30 to 60, with DS were enrolled in the Down Syndrome Biomarker Initiative (DSBI), a 3-year, observational, cohort study to demonstrate the feasibility of conducting AD intervention/prevention trials in adults with DS. We collected imaging data with 18F-AV-1451 tau PET, AV-45 amyloid PET, FDG PET, and volumetric MRI, as well as cognitive and functional measures and additional laboratory measures. All amyloid negative subjects imaged were tau-negative. Among the amyloid positive subjects, three had tau in regions associated with Braak stage VI, two at stage V, and one at stage II. Amyloid and tau burden correlated with age. The MRI analysis produced two distinct volumetric patterns. The first differentiated DS from normal (NL) and AD, did not correlate with age or amyloid, and was longitudinally stable. The second pattern reflected AD-like atrophy and differentiated NL from AD. Tau PET and MRI atrophy correlated with several cognitive and functional measures. Tau accumulation is associated with amyloid positivity and age, as well as with progressive neurodegeneration measurable using FDG and MRI. Tau correlates with cognitive decline, as do AD-specific hypometabolism and atrophy.

  4. Abnormal findings of magnetic resonance imaging (MRI) in patients with systemic lupus erythematosus involving the brain

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Akira; Okada, Jun; Kondo, Hirobumi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine); Kashiwazaki, Sadao

    1992-06-01

    To elucidate the clinical significance of MRI on central nervous system systemic lupus erythematosus (CNS-SLE), MRI and CT scans were performed in 35 patients with SLE, of 18 patients who had CNS manifestations at the time of MRI examinations. The investigations were also carried out in 17 patients without CNS-SLE. The rate of detection of abnormal findings on MRI in patients with CNS-SLE was 77.2% (14/18), which was high, as compared with the rate of those on CT scans (50%: 9/18). Especially, all of 4 patients with seizure and 3 patients with encephalopathy showed abnormal MRI findings, although respectively 50% and 33.3% of them had abnormal CT scan findings. MRI findings were classified into 4 groups below: (1) Large focal are as increased signal intensity at T2 weighted image. These were observed in 2 of 4 patients with seizure and 1 of 3 patients with encephalopathy, which were completely resolved after treatment. (2) Patchy subcortical foci of increased signal intensity at T2 weighted image. These were observed in 11 of 18 CNS-SLE and 7 of 17 without CNS-SLE, which were not detected by CT scan. (3) All of six patients with cerebral infarctions showed high signal intensity areas at T2 weighted image and low signal intensity areas at T1 weighted image. (4) Normal findings were observed in 4 of 18 CNS-SLE (22.2%). We concluded that MRI is useful for the evaluation of CNS-SLE and provides more information than CT scan. (author).

  5. Abnormal findings of magnetic resonance imaging (MRI) in patients with systemic lupus erythematosus involving the brain

    International Nuclear Information System (INIS)

    Ishikawa, Akira; Okada, Jun; Kondo, Hirobumi; Kashiwazaki, Sadao.

    1992-01-01

    To elucidate the clinical significance of MRI on central nervous system systemic lupus erythematosus (CNS-SLE), MRI and CT scans were performed in 35 patients with SLE, of 18 patients who had CNS manifestations at the time of MRI examinations. The investigations were also carried out in 17 patients without CNS-SLE. The rate of detection of abnormal findings on MRI in patients with CNS-SLE was 77.2% (14/18), which was high, as compared with the rate of those on CT scans (50%: 9/18). Especially, all of 4 patients with seizure and 3 patients with encephalopathy showed abnormal MRI findings, although respectively 50% and 33.3% of them had abnormal CT scan findings. MRI findings were classified into 4 groups below: 1) Large focal are as increased signal intensity at T2 weighted image. These were observed in 2 of 4 patients with seizure and 1 of 3 patients with encephalopathy, which were completely resolved after treatment. 2) Patchy subcortical foci of increased signal intensity at T2 weighted image. These were observed in 11 of 18 CNS-SLE and 7 of 17 without CNS-SLE, which were not detected by CT scan. 3) All of six patients with cerebral infarctions showed high signal intensity areas at T2 weighted image and low signal intensity areas at T1 weighted image. 4) Normal findings were observed in 4 of 18 CNS-SLE (22.2%). We concluded that MRI is useful for the evaluation of CNS-SLE and provides more information than CT scan. (author)

  6. Relationship of Hypertension, Blood Pressure, and Blood Pressure Control With White Matter Abnormalities in the Women’s Health Initiative Memory Study (WHIMS)—MRI Trial

    OpenAIRE

    Kuller, Lewis H.; Margolis, Karen L.; Gaussoin, Sarah A.; Bryan, Nick R.; Kerwin, Diana; Limacher, Marian; Wassertheil-Smoller, Sylvia; Williamson, Jeff; Robinson, Jennifer G.

    2010-01-01

    This paper evaluates the relationship of blood pressure (BP) levels at Women’s Health Initiative (WHI) baseline, treatment of hypertension, and white matter abnormalities among women in conjugated equine estrogen (CEE) and medroxyprogesterone acetate and CEE-alone arms. The WHI Memory Study—Magnetic Resonance Imaging (WHIMS-MRI) trial scanned 1424 participants. BP levels at baseline were significantly positively related to abnormal white matter lesion (WML) volumes. Participants treated for h...

  7. Volume based DCE-MRI breast cancer detection with 3D visualization system

    International Nuclear Information System (INIS)

    Chia, F.K.; Sim, K.S.; Chong, S.S.; Tan, S.T.; Ting, H.Y.; Abbas, S.F.; Omar, S.

    2011-01-01

    In this paper, a computer aided design auto probing system is presented to detect breast lesions based on Dynamic contrast enhanced Magnetic resonance imaging (DCE-MRI) images. The system is proposed in order to aid the radiologists and doctors in the interpretation of MRI breast images and enhance the detection accuracy. A series of approaches are presented to enhance the detection accuracy and refine the breast region of interest (Roil) automatically. Besides, a semi-quantitative analysis is used to segment the breast lesions from selected breast Roil and classify the detected tumour is whether benign, suspicious or malignant. The entire breast Roil including the detected tumour will display in 3D. The methodology has been applied on 104 sets of digital imaging and communications in medicine (Dico) breast MRI datasets images. The biopsy results are verified by 2 radiologists from Hospital Malaysia. The experimental results are demonstrated the proposed scheme can precisely identify breast cancer regions with 93% accuracy. (author)

  8. Development of an outdoor MRI system for measuring flow in a living tree

    Science.gov (United States)

    Nagata, Akiyoshi; Kose, Katsumi; Terada, Yasuhiko

    2016-04-01

    An outdoor MRI system for noninvasive, long-term measurements of sap flow in a living tree in its natural environment has been developed. An open-access, 0.2 T permanent magnet with a 160 mm gap was combined with a radiofrequency probe, planar gradient coils, electromagnetic shielding, several electrical units, and a waterproofing box. Two-dimensional cross-sectional images were acquired for a ring-porous tree, and the anatomical structures, including xylem and phloem, were identified. The MRI flow measurements demonstrated the diurnal changes in flow velocity in the stem on a per-pixel basis. These results demonstrate that our outdoor MRI system is a powerful tool for studies of water transport in outdoor trees.

  9. An optically coupled system for quantitative monitoring of MRI-induced RF currents into long conductors.

    Science.gov (United States)

    Zanchi, Marta G; Venook, Ross; Pauly, John M; Scott, Greig C

    2010-01-01

    The currents induced in long conductors such as guidewires by the radio-frequency (RF) field in magnetic resonance imaging (MRI) are responsible for potentially dangerous heating of surrounding media, such as tissue. This paper presents an optically coupled system with the potential to quantitatively measure the RF currents induced on these conductors. The system uses a self shielded toroid transducer and active circuitry to modulate a high speed light-emitting-diode transmitter. Plastic fiber guides the light to a photodiode receiver and transimpedance amplifier. System validation included a series of experiments with bare wires that compared wire tip heating by fluoroptic thermometers with the RF current sensor response. Validations were performed on a custom whole body 64 MHz birdcage test platform and on a 1.5 T MRI scanner. With this system, a variety of phenomena were demonstrated including cable trap current attenuation, lossy dielectric Q-spoiling and even transverse electromagnetic wave node patterns. This system should find applications in studies of MRI RF safety for interventional devices such as pacemaker leads, and guidewires. In particular, variations of this device could potentially act as a realtime safety monitor during MRI guided interventions.

  10. Performance of gadofosveset-enhanced MRI for staging rectal cancer nodes: can the initial promising results be reproduced?

    Energy Technology Data Exchange (ETDEWEB)

    Heijnen, Luc A.; Martens, Milou H. [Maastricht University Medical Center, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University Medical Center, Department of Surgery, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Lambregts, Doenja M.J.; Maas, Monique; Bakers, Frans C.H. [Maastricht University Medical Center, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Cappendijk, Vincent C. [Jeroen Bosch Ziekenhuis, Department of Radiology, ' s Hertogenbosch (Netherlands); Oliveira, Pedro [Instituto Portugues de Oncologia do Porto Francisco Gentil, Department of Radiology, Porto (Portugal); Lammering, Guido [Maastro Clinic, Radiation Oncology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Riedl, Robert G. [Maastricht University Medical Center, Department of Pathology, Maastricht (Netherlands); Beets, Geerard L. [Maastricht University Medical Center, Department of Surgery, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Beets-Tan, Regina G.H. [Maastricht University Medical Center, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2014-02-15

    A previous study showed promising results for gadofosveset-trisodium as a lymph node magnetic resonance imaging (MRI) contrast agent in rectal cancer. The aim of this study was to prospectively confirm the diagnostic performance of gadofosveset MRI for nodal (re)staging in rectal cancer in a second patient cohort. Seventy-one rectal cancer patients were prospectively included, of whom 13 (group I) underwent a primary staging gadofosveset MRI (1.5-T) followed by surgery (± preoperative 5 x 5 Gy) and 58 (group II) underwent both primary staging and restaging gadofosveset MRI after a long course of chemoradiotherapy followed by surgery. Nodal status was scored as (y)cN0 or (y)cN+ by two independent readers (R1, R2) with different experience levels. Results were correlated with histology on a node-by-node basis. Sensitivity, specificity and area under the receiver operating characteristics curve (AUC) were 94 %, 79 % and 0.89 for the more experienced R1 and 50 %, 83 % and 0.74 for the non-experienced R2. R2's performance improved considerably after a learning curve, to an AUC of 0.83. Misinterpretations mainly occurred in nodes located in the superior mesorectum, nodes located in between vessels and nodes containing micrometastases. This prospective study confirms the good diagnostic performance of gadofosveset MRI for nodal (re)staging in rectal cancer. (orig.)

  11. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Lutterbey, G. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)]. E-mail: goetz.lutterbey@ukb.uni-bonn.de; Grohe, C. [Department of Internal Medicine, University of Bonn (Germany); Gieseke, J. [PHILIPS Medical Systems, Best (Netherlands); Falkenhausen, M. von [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Morakkabati, N. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Wattjes, M.P. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Manka, R. [Department of Internal Medicine, University of Bonn (Germany); Trog, D. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany); Schild, H.H. [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53105 Bonn (Germany)

    2007-02-15

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  12. Initial experience with lung-MRI at 3.0 T: Comparison with CT and clinical data in the evaluation of interstitial lung disease activity

    International Nuclear Information System (INIS)

    Lutterbey, G.; Grohe, C.; Gieseke, J.; Falkenhausen, M. von; Morakkabati, N.; Wattjes, M.P.; Manka, R.; Trog, D.; Schild, H.H.

    2007-01-01

    Objectives: We evaluated the feasibility of highfield lung-MRI at 3.0 T. A comparison with Computed Tomography (CT) and clinical data regarding the assessment of inflammatory activity in patients with diffuse lung disease was performed. Material and methods: Prospective evaluation of 21 patients (15 males, 6 females, 43-80 y) with diffuse lung diseases who underwent clinical work-up inclusive laboratory tests, lung-function tests and transbronchial biopsy. After routine helical CT (additional 12 HRCT) a lung-MRI (3.0 Intera, Philips Medical Systems, Best, The Netherlands) using a T2-weighted, cardiac and respiratory triggered Fast-Spinecho-Sequence (TE/TR = 80/1500-2500 ms, 22 transverse slices, 7/2 mm slice-thickness/-gap) was performed. A pneumologist classified the cases into two groups: A = temporary acute interstitial disease or chronic interstitial lung disease with acute episode or superimposed infection/B = burned out interstitial lung disease without activity. Two blinded CT-radiologists graded the cases in active/inactive disease on the basis of nine morphological criteria each. A third radiologist rated the MRI-cases as active/inactive, depending on the signal-intensities of lung tissues. Results: The pneumologist classified 14 patients into group A and 7 patients into group B. Using CT, 6 cases were classified as active, 15 cases as inactive disease. With MRI 12 cases were classified as active and 9 cases as inactive. In the complete group of 21 patients MRI decisions and CT decisions respectively were false positive/false negative/correct in 2/4/15 respectively 0/8/13 cases. Correct diagnoses were obtained in 72% (MRI) respectively 62% (CT). In the subgroup of 12 cases including HRCT, MRI respectively CT were false positive/false negative/correct in 2/1/9 respectively 0/5/7 cases. Correct diagnoses were obtained in 75% (MRI) respectively 58% (CT). Conclusion: Highfield MRI of the lung is feasible and performed slightly better compared to CT in the

  13. Magnetic resonance imaging (MRI) of the cardiovascular system

    International Nuclear Information System (INIS)

    Yoshida, Shigeru

    1991-01-01

    Qualitative assessments of the hypertrophied myocardium were performed using spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) obtained by magnetic resonance imaging (MRI) in 15 normotensive patients with asymmetric septal hypertrophy (ASH), 10 hypertensive patients with concentric hypertrophy (CH) and 5 normal subjects (N). The changes of these values were evaluated related to cardiac cycle, and their usefulness in differentiating diseases. The wall thickness and internal dimension of the left ventricle (LV) in 10 cases were obtained using echocardiography and MRI, and there was a good correlation coefficient in wall thickness (r=0.987) and in internal dimension (r=0.991). Left ventricular short-axis images were obtained using ECG-gated spin-echo sequence (Te=30, 80 msec) and using inversion recovery sequence. T1 and T2 images were calculated at endsystolic and diastolic cardiac phases. The regional wall thickness (WT) and T1 and T2 values were measured in the anterior septum, anterior wall, lateral wall, posterior wall and posterior septum. Myocardial T1 and T2 values were significantly decreased in systole (T1: 185.6±37.9 msec, T2: 24.4±6.3 msec) compared to those in diastole (T1: 249.2±56.7 msec, T2: 31.7±9.4 msec). In both ASH and CH groups, significant correlations were observed between diastolic T1 values and WT (ASH: r=0.80, CH: r=0.45), and between diastolic T2 values and WT (ASH: r=0.58, CH: r=0.60). In the regions where diastolic WT were more than 17 mm, T1 values in the ASH group (343.4±40.5 msec) were significantly higher than those of the CH group (247.3±21.4 msec), although the mean wall thickness values were similar in both groups. These results indicate that myocardial relaxation times are related to cardiac cycle, wall thickness and types of hypertrophy. The T1 and T2 values at diastolic cardiac phase might be useful for distinguishing hypertrophic cardiomyopathy from hypertrophy due to hypertension. (author)

  14. Initial time singularities and admissible initial states for a system of coupled scalar fields

    Energy Technology Data Exchange (ETDEWEB)

    Baacke, Juergen [Technische Univ. Dortmund (Germany). Fakultaet Physik; Kevlishvili, Nina [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); GAS, Tbilisi (Georgia). Andronikashvili Inst. of Physics

    2009-10-15

    We discuss the problem of initial states for a system of coupled scalar fields out of equilibrium in the one-loop approximation. The fields consist of classical background fields, taken constant in space, and quantum fluctuations. If the initial state is the adiabatic vacuum, i.e., the ground state of a Fock space of particle excitations that diagonalize the mass matrix, the energy-momentum tensor is infinite at t=0, its most singular part behaves as 1/t. When the system is coupled to gravity this presents a problem that we solve by a Bogoliubov transformation of the naive initial state. As a side result we also discuss the canonical formalism and the adiabatic particle number for such a system. Most of the formalism is presented for Minkowksi space. Embedding the system and its dynamics into a flat FRW universe is straightforward and we briefly address the essential modifications. (orig.)

  15. Initial time singularities and admissible initial states for a system of coupled scalar fields

    International Nuclear Information System (INIS)

    Baacke, Juergen; Kevlishvili, Nina; GAS, Tbilisi

    2009-10-01

    We discuss the problem of initial states for a system of coupled scalar fields out of equilibrium in the one-loop approximation. The fields consist of classical background fields, taken constant in space, and quantum fluctuations. If the initial state is the adiabatic vacuum, i.e., the ground state of a Fock space of particle excitations that diagonalize the mass matrix, the energy-momentum tensor is infinite at t=0, its most singular part behaves as 1/t. When the system is coupled to gravity this presents a problem that we solve by a Bogoliubov transformation of the naive initial state. As a side result we also discuss the canonical formalism and the adiabatic particle number for such a system. Most of the formalism is presented for Minkowksi space. Embedding the system and its dynamics into a flat FRW universe is straightforward and we briefly address the essential modifications. (orig.)

  16. Predicting response before initiation of neoadjuvant chemotherapy in breast cancer using new methods for the analysis of dynamic contrast enhanced MRI (DCE MRI) data

    Science.gov (United States)

    DeGrandchamp, Joseph B.; Whisenant, Jennifer G.; Arlinghaus, Lori R.; Abramson, V. G.; Yankeelov, Thomas E.; Cárdenas-Rodríguez, Julio

    2016-03-01

    The pharmacokinetic parameters derived from dynamic contrast enhanced (DCE) MRI have shown promise as biomarkers for tumor response to therapy. However, standard methods of analyzing DCE MRI data (Tofts model) require high temporal resolution, high signal-to-noise ratio (SNR), and the Arterial Input Function (AIF). Such models produce reliable biomarkers of response only when a therapy has a large effect on the parameters. We recently reported a method that solves the limitations, the Linear Reference Region Model (LRRM). Similar to other reference region models, the LRRM needs no AIF. Additionally, the LRRM is more accurate and precise than standard methods at low SNR and slow temporal resolution, suggesting LRRM-derived biomarkers could be better predictors. Here, the LRRM, Non-linear Reference Region Model (NRRM), Linear Tofts model (LTM), and Non-linear Tofts Model (NLTM) were used to estimate the RKtrans between muscle and tumor (or the Ktrans for Tofts) and the tumor kep,TOI for 39 breast cancer patients who received neoadjuvant chemotherapy (NAC). These parameters and the receptor statuses of each patient were used to construct cross-validated predictive models to classify patients as complete pathological responders (pCR) or non-complete pathological responders (non-pCR) to NAC. Model performance was evaluated using area under the ROC curve (AUC). The AUC for receptor status alone was 0.62, while the best performance using predictors from the LRRM, NRRM, LTM, and NLTM were AUCs of 0.79, 0.55, 0.60, and 0.59 respectively. This suggests that the LRRM can be used to predict response to NAC in breast cancer.

  17. Black blood MRI in suspected large artery primary angiitis of the central nervous system.

    Science.gov (United States)

    Pfefferkorn, Thomas; Linn, Jennifer; Habs, Maximilian; Opherk, Christina; Cyran, Clemens; Ottomeyer, Caroline; Straube, Andreas; Dichgans, Martin; Nikolaou, Konstantin; Saam, Tobias

    2013-07-01

    Single case reports suggest that black blood MRI (T1-weighted fat and blood suppressed sequences with and without contrast injection; BB-MRI) may visualize intracranial vessel wall contrast enhancement (CE) in primary angiitis of the central nervous system (PACNS). In this single-center observational pilot study we prospectively investigated the value of BB-MRI in the diagnosis of large artery PACNS. Patients with suspected large artery PACNS received a standardized diagnostic program including BB-MRI. Vessel wall CE was graded (grade 0-2) by two experienced readers blinded to clinical data and correlated to the final diagnosis. Four of 12 included patients received a final diagnosis of PACNS. All of them showed moderate (grade 1) to strong (grade 2) vessel wall CE at the sites of stenosis. A moderate (grade 1) vessel wall CE grade was also observed in 6 of the remaining 8 patients in whom alternative diagnoses were made: arteriosclerotic disease (n = 4), intracranial dissection (n = 1), and Moyamoya disease (n = 1). Our pilot study demonstrates that vessel wall CE is a frequent finding in PACNS and its mimics. Larger trials will be necessary to evaluate the utility of BB-MRI in the diagnostic workup of PACNS. Copyright © 2012 by the American Society of Neuroimaging.

  18. Value of MRI of the brain in patients with systemic lupus erythematosus and neurologic disturbance

    International Nuclear Information System (INIS)

    Jennings, J.E.; Sundgren, P.C.; Maly, P.; Attwood, J.; McCune, J.

    2004-01-01

    Our objective was to review the frequency and pattern of signal abnormalities seen on conventional MRI in patients with suspected neuropsychiatric systemic lupus erythematosus (NP-SLE). We reviewed 116 MRI examinations of the brain performed on 85 patients with SLE, (81 women, four men, aged 21-78 years, mean 40.6 years) presenting with neurological disturbances. MRI was normal or nearly normal in 34%. In 60% high-signal lesions were observed on T2-weighted images, frequently in the frontal and parietal subcortical white matter. Infarct-like lesions involving gray and white matter were demonstrated in 21 of cases. Areas of restricted diffusion were seen in 12 of the 67 patients who underwent diffusion-weighted imaging. Other abnormalities included loss of brain volume, hemorrhage, meningeal enhancement, and bilateral high signal in occipital white-matter. The MRI findings alone did not allow us to distinguish between thromboembolic and inflammatory events in many patients. Some patients with normal MRI improved clinically while on immunosuppressive therapy. More sensitive and/or specific imaging methods, such as spectroscopy and perfusion-weighted imaging, should be investigated in these subgroups of patients with suspected NP-SLE. (orig.)

  19. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Via Golgi 40, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman [Mediso Medical Imaging Systems, Alsotorokvesz 14, H-1022 Budapest (Hungary); Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto [Fondazione Bruno Kessler (FBK), Via Sommarive, 18, 38123 Trento (Italy); Rieger, Jan [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Niendorf, Thoralf [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Berlin Ultrahigh Field Facility (B.UniversityF.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin (Germany)

    2014-07-29

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  20. PET/MRI of central nervous system: current status and future perspective

    International Nuclear Information System (INIS)

    Yang, Zhen Lu; Zhang, Long Jiang

    2016-01-01

    Imaging plays an increasingly important role in the early diagnosis, prognosis prediction and therapy response evaluation of central nervous system (CNS) diseases. The newly emerging hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) can perform ''one-stop-shop'' evaluation, including anatomic, functional, biochemical and metabolic information, even at the molecular level, for personalised diagnoses and treatments of CNS diseases. However, there are still several problems to be resolved, such as appropriate PET detectors, attenuation correction and so on. This review will introduce the basic physical principles of PET/MRI and its potential clinical applications in the CNS. We also provide the future perspectives for this field. (orig.)

  1. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    International Nuclear Information System (INIS)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo; Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman; Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto; Rieger, Jan; Niendorf, Thoralf

    2014-01-01

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  2. Hip Inflammation MRI Scoring System (HIMRISS) to predict response to hyaluronic acid injection in hip osteoarthritis

    DEFF Research Database (Denmark)

    Deseyne, Nicolas; Conrozier, Thierry; Lellouche, Henri

    2018-01-01

    OBJECTIVE: To assess predictors of response, according to hip MRI inflammatory scoring system (HIMRISS), in a sample of patients with hip osteoarthritis (OA) treated by hyaluronic acid (HA) injection. METHOD: Sixty patients with hip OA were included. Clinical outcomes were assessed at baseline...... SP=0.97, sensitivity SN=0.39, and positive and negative predictive values of 0.91 and 0.64, respectively. CONCLUSION: HIMRISS is reliable for total scores and sub-domains. It permits identification of responders to HA injection in hip OA patients........64, 0.83 and 0.78. Associations between MRI features and clinical data were assessed. Logistic regression (univariate and multivariate) was used to explore associations between MRI features and response to HA injection, according to WOMAC50 response at three months. RESULTS: In total, 45.5% of patients...

  3. Skeletal age assessment in children using an open compact MRI system.

    Science.gov (United States)

    Terada, Yasuhiko; Kono, Saki; Tamada, Daiki; Uchiumi, Tomomi; Kose, Katsumi; Miyagi, Ryo; Yamabe, Eiko; Yoshioka, Hiroshi

    2013-06-01

    MRI may be a noninvasive and alternative tool for skeletal age assessment in children, although few studies have reported on this topic. In this article, skeletal age was assessed over a wide range of ages using an open, compact MRI optimized for the imaging of a child's hand and wrist, and its validity was evaluated. MR images and their three-dimensional segmentation visualized detailed skeletal features of each bone in the hand and wrist. Skeletal age was then independently scored from the MR images by two raters, according to the Tanner-Whitehouse Japan system. The skeletal age assessed by MR rating demonstrated a strong positive correlation with chronological age. The intrarater and inter-rater reproducibilities were significantly high. These results demonstrate the validity and reliability of skeletal age assessment using MRI. Copyright © 2012 Wiley Periodicals, Inc.

  4. Assessment of three different software systems in the evaluation of dynamic MRI of the breast

    International Nuclear Information System (INIS)

    Kurz, K.D.; Steinhaus, D.; Klar, V.; Cohnen, M.; Wittsack, H.J.; Saleh, A.; Moedder, U.; Blondin, D.

    2009-01-01

    Objective: The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ('CADstream' and '3TP') and one self-developed software system ('Mammatool'). Materials and methods: Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. Results: There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. 'CADstream' showed the best score on subjective quality criteria. '3TP' showed the lowest number of false-positive results. 'Mammatool' produced the lowest number of benign tissues indicated with parametric overlay. Conclusion: All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable

  5. Assessment of three different software systems in the evaluation of dynamic MRI of the breast.

    Science.gov (United States)

    Kurz, K D; Steinhaus, D; Klar, V; Cohnen, M; Wittsack, H J; Saleh, A; Mödder, U; Blondin, D

    2009-02-01

    The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ("CADstream" and "3TP") and one self-developed software system ("Mammatool"). Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. "CADstream" showed the best score on subjective quality criteria. "3TP" showed the lowest number of false-positive results. "Mammatool" produced the lowest number of benign tissues indicated with parametric overlay. All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable.

  6. Design and characterization of Stormram 4 : an MRI-compatible robotic system for breast biopsy

    NARCIS (Netherlands)

    Groenhuis, Vincent; Siepel, Françoise Jeanette; Veltman, Jeroen; Stramigioli, Stefano

    2017-01-01

    Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able

  7. Reliability of the echoMRI infant system for water and fat measurements in newborns

    Science.gov (United States)

    The precision and accuracy of a quantitative magnetic resonance (EchoMRI Infants) system in newborns were determined. Canola oil and drinking water phantoms (increments of 10 g to 1.9 kg) were scanned four times. Instrument reproducibility was assessed from three scans (within 10 minutes) in 42 heal...

  8. Intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injuries

    International Nuclear Information System (INIS)

    Wangensteen, Arnlaug; Tol, Johannes L.; Roemer, Frank W.; Bahr, Roald; Dijkstra, H. Paul; Crema, Michel D.; Farooq, Abdulaziz; Guermazi, Ali

    2017-01-01

    Highlights: • Three different MRI grading and classification systems for acute hamstring injuries are overall reliable. • Reliability for the subcategories within these MRI grading and classification systems remains, however, unclear. - Abstract: Objective: To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Methods: Male athletes (n = 40) with clinical diagnosis of acute hamstring injury and MRI ≤5 days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. Results: We observed ‘substantial’ to ‘almost perfect’ intra- (κ range 0.65–1.00) and interrater reliability (κ range 0.77–1.00) with percentage agreement 83–100% and 88–100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range −0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. Conclusions: The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated ‘substantial' to ‘almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear.

  9. Intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injuries

    Energy Technology Data Exchange (ETDEWEB)

    Wangensteen, Arnlaug, E-mail: arnlaug.wangensteen@nih.no [Aspetar, Orthopaedic and Sports Medicine Hospital, Doha (Qatar); Oslo Sports Trauma Research Center, Department of Sports Medicine, Norwegian School of Sport Sciences, Oslo (Norway); Tol, Johannes L., E-mail: johannes.tol@aspetar.com [Aspetar, Orthopaedic and Sports Medicine Hospital, Doha (Qatar); Amsterdam Center for Evidence Sports Medicine, Academic Medical Center (Netherlands); The Sports Physician Group, OLVG, Amsterdam (Netherlands); Roemer, Frank W. [Quantitative Imaging Center, Department of Radiology, Boston University School of Medicine, Boston, MA (United States); Department of Radiology, University of Erlangen-Nuremberg, Erlangen (Germany); Bahr, Roald [Aspetar, Orthopaedic and Sports Medicine Hospital, Doha (Qatar); Oslo Sports Trauma Research Center, Department of Sports Medicine, Norwegian School of Sport Sciences, Oslo (Norway); Dijkstra, H. Paul [Aspetar, Orthopaedic and Sports Medicine Hospital, Doha (Qatar); Crema, Michel D. [Quantitative Imaging Center, Department of Radiology, Boston University School of Medicine, Boston, MA (United States); Department of Radiology, Saint-Antoine Hospital, University Paris VI, Paris (France); Farooq, Abdulaziz [Aspetar, Orthopaedic and Sports Medicine Hospital, Doha (Qatar); Guermazi, Ali [Quantitative Imaging Center, Department of Radiology, Boston University School of Medicine, Boston, MA (United States)

    2017-04-15

    Highlights: • Three different MRI grading and classification systems for acute hamstring injuries are overall reliable. • Reliability for the subcategories within these MRI grading and classification systems remains, however, unclear. - Abstract: Objective: To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Methods: Male athletes (n = 40) with clinical diagnosis of acute hamstring injury and MRI ≤5 days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. Results: We observed ‘substantial’ to ‘almost perfect’ intra- (κ range 0.65–1.00) and interrater reliability (κ range 0.77–1.00) with percentage agreement 83–100% and 88–100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range −0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. Conclusions: The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated ‘substantial' to ‘almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear.

  10. Development of an Optical Fiber-Based MR Compatible Gamma Camera for SPECT/MRI Systems

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Tadashi; Kanai, Yasukazu; Watabe, Hiroshi; Hatazawa, Jun

    2015-02-01

    Optical fiber is a promising material for integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) PET/MRI systems. Because its material is plastic, it has no interference between MRI. However, it is unclear whether this material can also be used for a single photon emission tomography (SPECT)/MRI system. For this purpose, we developed an optical fiber-based block detector for a SPECT/MRI system and tested its performance by combining 1.2 ×1.2 ×6 mm Y2SiO5 (YSO) pixels into a 15 ×15 block and was coupled it to an optical fiber image guide that used was 0.5-mm in diameter with 80-cm long double clad fibers. The image guide had 22 ×22 mm rectangular input and an equal size output. The input of the optical fiber-based image guide was bent at 90 degrees, and the output was optically coupled to a 1-in square high quantum efficiency position sensitive photomultiplier tube (HQE-PSPMT). The parallel hole, 7-mm-thick collimator made of tungsten plastic was mounted on a YSO block. The diameter of the collimator holes was 0.8 mm which was positioned one-to-one coupled to the YSO pixels. We evaluated the intrinsic and system performances. We resolved most of the YSO pixels in a two-dimensional histogram for Co-57 gamma photons (122-keV) with an average peak-to-value ratio of 1.5. The energy resolution was 38% full-width at half-maximum (FWHM). The system resolution was 1.7-mm FWHM, 1.5 mm from the collimator surface, and the sensitivity was 0.06%. Images of a Co-57 point source could be successfully obtained inside 0.3 T MRI without serious interference. We conclude that the developed optical fiber-based YSO block detector is promising for SPECT/MRI systems.

  11. Development of contaminant detection system based on ultra-low field SQUID-NMR/MRI

    International Nuclear Information System (INIS)

    Tsunaki, S; Yamamoto, M; Hatta, J; Hatsukade, Y; Tanaka, S

    2014-01-01

    We have developed an ultra-low field (ULF) NMR/MRI system using an HTS-rf-SQUID and evaluated performance of the system as a contaminant detection system for foods and drinks. In this work, we measured 1D MRIs from water samples with or without various contaminants, such as aluminum and glass balls using the system. In the 1D MRIs, changes of the MRI spectra were detected, corresponding to positions of the contaminants. We measured 2D MRIs from food samples with and without a hole. In the 2D MRIs, the hole position in the sample was well visualized. These results show that the feasibility of the system to detect and localize contaminants in foods and drinks.

  12. Comparison of pharmacokinetic MRI and [{sup 18}F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Henze, M. [Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany); Knopp, M.V.; Doll, J.; Hawighorst, H. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Lucht, R. [Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Junkermann, H. [Dept. of Gynaecological Radiology, Univ. of Heidelberg (Germany); Haberkorn, U. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany)

    2001-10-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  13. Comparison of pharmacokinetic MRI and [18F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    International Nuclear Information System (INIS)

    Brix, G.; Henze, M.; Knopp, M.V.; Doll, J.; Hawighorst, H.; Lucht, R.; Junkermann, H.; Haberkorn, U.

    2001-01-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  14. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  15. Japan Meteorological Agency/Meteorological Research Institute-Coupled Prediction System version 2 (JMA/MRI-CPS2): atmosphere-land-ocean-sea ice coupled prediction system for operational seasonal forecasting

    Science.gov (United States)

    Takaya, Yuhei; Hirahara, Shoji; Yasuda, Tamaki; Matsueda, Satoko; Toyoda, Takahiro; Fujii, Yosuke; Sugimoto, Hiroyuki; Matsukawa, Chihiro; Ishikawa, Ichiro; Mori, Hirotoshi; Nagasawa, Ryoji; Kubo, Yutaro; Adachi, Noriyuki; Yamanaka, Goro; Kuragano, Tsurane; Shimpo, Akihiko; Maeda, Shuhei; Ose, Tomoaki

    2018-02-01

    This paper describes the Japan Meteorological Agency/Meteorological Research Institute-Coupled Prediction System version 2 (JMA/MRI-CPS2), which was put into operation in June 2015 for the purpose of performing seasonal predictions. JMA/MRI-CPS2 has various upgrades from its predecessor, JMA/MRI-CPS1, including improved resolution and physics in its atmospheric and oceanic components, introduction of an interactive sea-ice model and realistic initialization of its land component. Verification of extensive re-forecasts covering a 30-year period (1981-2010) demonstrates that JMA/MRI-CPS2 possesses improved seasonal predictive skills for both atmospheric and oceanic interannual variability as well as key coupled variability such as the El Niño-Southern Oscillation (ENSO). For ENSO prediction, the new system better represents the forecast uncertainty and transition/duration of ENSO phases. Our analysis suggests that the enhanced predictive skills are attributable to incremental improvements resulting from all of the changes, as is apparent in the beneficial effects of sea-ice coupling and land initialization on 2-m temperature predictions. JMA/MRI-CPS2 is capable of reasonably representing the seasonal cycle and secular trends of sea ice. The sea-ice coupling remarkably enhances the predictive capability for the Arctic 2-m temperature, indicating the importance of this factor, particularly for seasonal predictions in the Arctic region.

  16. MRI-guided periradicular nerve root infiltration therapy in low-field (0.23-T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Sequeiros, Roberto Blanco; Ojala, Risto O.; Klemola, Rauli; Jyrkinen, Lasse; Tervonen, Osmo A.; Vaara, Teuvo J.

    2002-01-01

    The purpose of this study was to evaluate the feasibility of the MRI-guided periradicular nerve root infiltration therapy. Sixty-seven nerve root infiltrations under MRI guidance were done for 61 patients suffering from lumbosacral radicular pain. Informed consent was acquired from all patients. A 0.23-T open-MRI scanner with interventional tools (Outlook Proview, Philips Medical Systems, MR Technologies, Finland) was used. A surface coil was used in all cases. Nerve root infiltration was performed with MRI-compatible 20-G needle (Chiba type MReye, Cook, Bloomington, Ind.; or Manan type, MD Tech, Florida). The evaluation of clinical outcome was achieved with 6 months of clinical follow-up and questionnaire. The effect of nerve root infiltration to the radicular pain was graded: 1=good to excellent, i.e., no pain or not disturbing pain allowing normal physical activity at 3 months from the procedure; 2=temporary, i.e., temporary relief of pain; 3=no relief of pain; and 4=worsening of pain. As an adjunct to MRI-guided positioning of the needle the correct needle localization by the nerve root was confirmed with saline injection to nerve root channel and single-shot fast spin echo (SSFSE) imaging. The MRI guidance allowed adequate needle positioning in all but 1 case (98.5%). This failure was caused by degeneration-induced changes in anatomy. Of patients, 51.5% had good to excellent effect with regard to radicular pain from the procedure, 22.7% had temporary relief, 21.2% had no effect, and in 4.5% the pain worsened. Our results show that MRI guidance is accurate and safe in performing nerve root infiltration at lumbosacral area. The results of radicular pain relief from nerve root infiltration are comparable to CT or fluoroscopy studies on the subject. (orig.)

  17. Visualization of suspicious lesions in breast MRI based on intelligent neural systems

    Science.gov (United States)

    Twellmann, Thorsten; Lange, Oliver; Nattkemper, Tim Wilhelm; Meyer-Bäse, Anke

    2006-05-01

    Intelligent medical systems based on supervised and unsupervised artificial neural networks are applied to the automatic visualization and classification of suspicious lesions in breast MRI. These systems represent an important component of future sophisticated computer-aided diagnosis systems and enable the extraction of spatial and temporal features of dynamic MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogenity of the cancerous tissue, these techniques reveal the malignant, benign and normal kinetic signals and and provide a regional subclassification of pathological breast tissue. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging.

  18. Investigation of fast initialization of spacecraft bubble memory systems

    Science.gov (United States)

    Looney, K. T.; Nichols, C. D.; Hayes, P. J.

    1984-01-01

    Bubble domain technology offers significant improvement in reliability and functionality for spacecraft onboard memory applications. In considering potential memory systems organizations, minimization of power in high capacity bubble memory systems necessitates the activation of only the desired portions of the memory. In power strobing arbitrary memory segments, a capability of fast turn on is required. Bubble device architectures, which provide redundant loop coding in the bubble devices, limit the initialization speed. Alternate initialization techniques are investigated to overcome this design limitation. An initialization technique using a small amount of external storage is demonstrated.

  19. CT and MRI findings of cerebral ischemic lesions in the cortical and perforating arterial system

    Energy Technology Data Exchange (ETDEWEB)

    Kameyama, Masakuni; Udaka, Fukashi; Nishinaka, Kazuto; Kodama, Mitsuo; Urushidani, Makoto; Kawamura, Kazuyuki; Inoue, Haruhisa; Kageyama, Taku [Sumitomo Hospital, Osaka (Japan)

    1995-07-01

    It is clinically useful to divide the location of infarction into the cortical and perforating arterial system. Computerized tomography (CT) and magnetic resonance imaging (MRI) now make the point of infarction a simple and useful task in daily practice. The diagnostic modality has also demonstrated that risk factors and clinical manifestations are different for infarction in the cortical as opposed to the perforating system. In this paper, we present various aspects of images of cerebral ischemia according to CT and/or MRI findings. With the advance of imaging mechanics, diagnostic capability of CT or/and MRI for cerebral infarction has markedly been improved. We must consider these points on evaluating the previously reported results. In addition, we always consider the pathological background of these image-findings for the precise interpretation of their clinical significance. In some instances, dynamic study such as PET or SPECT is needed for real interpretations of CT and/or MRI images. We paid special reference to lacunar stroke and striatocapsular infarct. In addition, `branch atheromatous disease (Caplan)` was considered, in particular, for their specific clinical significances. Large striatocapsular infarcts frequently show cortical signs and symptoms such as aphasia or agnosia in spite of their subcortical localization. These facts, although have previously been known, should be re-considered for their pathoanatomical mechanism. (author).

  20. CT and MRI findings of cerebral ischemic lesions in the cortical and perforating arterial system

    International Nuclear Information System (INIS)

    Kameyama, Masakuni; Udaka, Fukashi; Nishinaka, Kazuto; Kodama, Mitsuo; Urushidani, Makoto; Kawamura, Kazuyuki; Inoue, Haruhisa; Kageyama, Taku

    1995-01-01

    It is clinically useful to divide the location of infarction into the cortical and perforating arterial system. Computerized tomography (CT) and magnetic resonance imaging (MRI) now make the point of infarction a simple and useful task in daily practice. The diagnostic modality has also demonstrated that risk factors and clinical manifestations are different for infarction in the cortical as opposed to the perforating system. In this paper, we present various aspects of images of cerebral ischemia according to CT and/or MRI findings. With the advance of imaging mechanics, diagnostic capability of CT or/and MRI for cerebral infarction has markedly been improved. We must consider these points on evaluating the previously reported results. In addition, we always consider the pathological background of these image-findings for the precise interpretation of their clinical significance. In some instances, dynamic study such as PET or SPECT is needed for real interpretations of CT and/or MRI images. We paid special reference to lacunar stroke and striatocapsular infarct. In addition, 'branch atheromatous disease (Caplan)' was considered, in particular, for their specific clinical significances. Large striatocapsular infarcts frequently show cortical signs and symptoms such as aphasia or agnosia in spite of their subcortical localization. These facts, although have previously been known, should be re-considered for their pathoanatomical mechanism. (author)

  1. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  2. Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    Science.gov (United States)

    Salvati, Roberto; Hitti, Eric; Bellanger, Jean-Jacques; Saint-Jalmes, Hervé; Gambarota, Giulio

    2016-06-01

    Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. Various numerical phantoms with a given fat fraction, T2* and field map were designed. The k-space of numerical phantoms was converted into RF signals to generate virtual phantoms. MRI experiments were performed at 4.7T using a multi-gradient-echo sequence on virtual and physical phantoms. The data acquisition of virtual and physical phantoms was simultaneous. Decomposition of the water and fat signals was performed using a complex-based water-fat separation algorithm. Overall, a good agreement was observed between the fat fraction, T2* and phase map values of the virtual and numerical phantoms. In particular, fat fractions of 10.5±0.1 (vs 10% of the numerical phantom), 20.3±0.1 (vs 20%) and 30.4±0.1 (vs 30%) were obtained in virtual phantoms. The ViP MRI method allows for generating imaging phantoms that i) mimic water-fat systems and ii) can be analyzed with water-fat separation algorithms based on complex data. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Visual MRI grading system to evaluate atrophy of the supeaspinatus muscle

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Kyoung; Hong, Sung Hwan; Yoo, Hye Jin; Choi, Ja Young; Kim, Sae Hoon; Choi, Jung Ah; Kang, Heung Sik [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    To investigate the interobserver reproducibility and diagnostic feasibility of a visual grading system for assessing atrophy of the supraspinatus muscle on magnetic resonance imaging (MRI). Three independent radiologists retrospectively evaluated the occupying ratio of the supraspinatus muscle in the supraspinatus fossa on 192 shoulder MRI examinations in 188 patients using a 3-point visual grading system (1, ≥ 60%; 2, 30-59%; 3, < 30%) on oblique sagittal T1-weighted images. The inter-reader agreement and the agreement with the reference standard (3-point grades according to absolute occupying ratio values quantitatively measured by directly contouring the muscles on MRI) were analyzed using weighted kappa. The visual grading was applied by a single reader to a group of 100 consecutive patients who had undergone rotator cuff repair to retrospectively determine the association between the visual grades at preoperative state and postsurgical occurrences of retear. The inter-reader weighted kappa value for the visual grading was 0.74 when averaged across three reader pairs (0.70-0.77 for individual reader pairs). The weighted kappa value between the visual grading and the reference standard ranged from 0.75 to 0.83. There was a significant difference in retear rates of the rotator cuff between the 3 visual grades of supraspinatus muscle atrophy on MRI in univariable analysis (p < 0.001), but not in multivariable analysis (p = 0.026). The 3-point visual grading system may be a feasible method to assess the severity of supraspinatus muscle atrophy on MRI and assist in the clinical management of patients with rotator cuff tear.

  4. Visual MRI grading system to evaluate atrophy of the supeaspinatus muscle

    International Nuclear Information System (INIS)

    Lim, Hyun Kyoung; Hong, Sung Hwan; Yoo, Hye Jin; Choi, Ja Young; Kim, Sae Hoon; Choi, Jung Ah; Kang, Heung Sik

    2014-01-01

    To investigate the interobserver reproducibility and diagnostic feasibility of a visual grading system for assessing atrophy of the supraspinatus muscle on magnetic resonance imaging (MRI). Three independent radiologists retrospectively evaluated the occupying ratio of the supraspinatus muscle in the supraspinatus fossa on 192 shoulder MRI examinations in 188 patients using a 3-point visual grading system (1, ≥ 60%; 2, 30-59%; 3, < 30%) on oblique sagittal T1-weighted images. The inter-reader agreement and the agreement with the reference standard (3-point grades according to absolute occupying ratio values quantitatively measured by directly contouring the muscles on MRI) were analyzed using weighted kappa. The visual grading was applied by a single reader to a group of 100 consecutive patients who had undergone rotator cuff repair to retrospectively determine the association between the visual grades at preoperative state and postsurgical occurrences of retear. The inter-reader weighted kappa value for the visual grading was 0.74 when averaged across three reader pairs (0.70-0.77 for individual reader pairs). The weighted kappa value between the visual grading and the reference standard ranged from 0.75 to 0.83. There was a significant difference in retear rates of the rotator cuff between the 3 visual grades of supraspinatus muscle atrophy on MRI in univariable analysis (p < 0.001), but not in multivariable analysis (p = 0.026). The 3-point visual grading system may be a feasible method to assess the severity of supraspinatus muscle atrophy on MRI and assist in the clinical management of patients with rotator cuff tear.

  5. Differentiation between active and chronic Crohn's disease using MRI small-bowel motility examinations — Initial experience

    International Nuclear Information System (INIS)

    Bickelhaupt, S.; Froehlich, J.M.; Cattin, R.; Patuto, N.; Tutuian, R.; Wentz, K.U.; Culmann, J.L.; Raible, S.; Bouquet, H.; Bill, U.; Patak, M.A.

    2013-01-01

    Aim: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. Material and methods: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). Results: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). Conclusion: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with

  6. SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

    Energy Technology Data Exchange (ETDEWEB)

    James, J; Place, V; Panda, A [Mayo Clinic, Scottsdale, AZ (United States); Edmonson, H [Mayo Clinic College of Medicine, Rochester, MN (United States); Felmlee, J [Mayo Clinic, Rochester, MN (United States); Pooley, R [Mayo Clinic, Jacksonville, FL (United States)

    2014-06-01

    Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over

  7. SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

    International Nuclear Information System (INIS)

    James, J; Place, V; Panda, A; Edmonson, H; Felmlee, J; Pooley, R

    2014-01-01

    Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over

  8. A compact 3 T all HTS cryogen-free MRI system

    Science.gov (United States)

    Parkinson, B. J.; Bouloukakis, K.; Slade, R. A.

    2017-12-01

    We have designed and built a passively shielded, cryogen-free 3 T 160 mm bore bismuth strontium calcium copper oxide HTS magnet with shielded gradient coils suitable for use in small animal imaging applications. The magnet is cooled to approximately 16 K using a two-stage cryocooler and is operated at 200 A. The magnet has been passively shimmed so as to achieve ±10 parts per million (ppm) homogeneity over a 60 mm diameter imaging volume. We have demonstrated that B 0 temporal stability is fit-for-purpose despite the magnet operating in the driven mode. The system has produced good quality spin-echo and gradient echo images. This compact HTS-MRI system is emerging as a true alternative to conventional low temperature superconductor based cryogen-free MRI systems, with much more efficient cryogenics since it operates entirely from a single phase alternating current electrical supply.

  9. MRI of the spinocerebellar degeneration (multiple system atrophy, Holmes type, and Menzel-Joseph type)

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki.

    1991-01-01

    We have analyzed MRI in 33 patients with several forms of spinocerebellar degeneration; 17 with multiple system atrophy, 10 with Holmes type, and 6 with Menzel-Joseph type. The MRIs were obtained using a 1.5-T GEMR System. Patients with multiple system atrophy demonstrated: atrophy of the brain stem, particularly basis pontis; decreased signal intensity of the white matter of pons; atrophy of the white matter of cerebellum; atrophy and decreased signal intensity of the putamen, particularly along their lateral and posterior portions; and atrophy of the cerebrum. Patients with Holmes type showed: atrophy of the cerebellum; atrophy of the vermis more than hemispheres; and nuclei of the cerebellum with no decreased intensity on T 2 -weighted sequences. Patients with Menzel-Joseph type demonstrated moderate atrophy of the brain stem and mild atrophy of the white matter of cerebellum. MRI is a useful diagnostic tool in the management of the spinocerebellar degeneration. (author)

  10. A dimensionless dynamic contrast enhanced MRI parameter for intra-prostatic tumour target volume delineation: initial comparison with histology

    Science.gov (United States)

    Hrinivich, W. Thomas; Gibson, Eli; Gaed, Mena; Gomez, Jose A.; Moussa, Madeleine; McKenzie, Charles A.; Bauman, Glenn S.; Ward, Aaron D.; Fenster, Aaron; Wong, Eugene

    2014-03-01

    Purpose: T2 weighted and diffusion weighted magnetic resonance imaging (MRI) show promise in isolating prostate tumours. Dynamic contrast enhanced (DCE)-MRI has also been employed as a component in multi-parametric tumour detection schemes. Model-based parameters such as Ktrans are conventionally used to characterize DCE images and require arterial contrast agent (CR) concentration. A robust parameter map that does not depend on arterial input may be more useful for target volume delineation. We present a dimensionless parameter (Wio) that characterizes CR wash-in and washout rates without requiring arterial CR concentration. Wio is compared to Ktrans in terms of ability to discriminate cancer in the prostate, as demonstrated via comparison with histology. Methods: Three subjects underwent DCE-MRI using gadolinium contrast and 7 s imaging temporal resolution. A pathologist identified cancer on whole-mount histology specimens, and slides were deformably registered to MR images. The ability of Wio maps to discriminate cancer was determined through receiver operating characteristic curve (ROC) analysis. Results: There is a trend that Wio shows greater area under the ROC curve (AUC) than Ktrans with median AUC values of 0.74 and 0.69 respectively, but the difference was not statistically significant based on a Wilcoxon signed-rank test (p = 0.13). Conclusions: Preliminary results indicate that Wio shows potential as a tool for Ktrans QA, showing similar ability to discriminate cancer in the prostate as Ktrans without requiring arterial CR concentration.

  11. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  12. Open-Access, Low-Magnetic-Field MRI System for Lung Research

    Science.gov (United States)

    Mair, Ross W.; Rosen, Matthew S.; Tsai, Leo L.; Walsworth, Ronald L.; Hrovat, Mirko I.; Patz, Samuel; Ruset, Iullian C.; Hersman, F. William

    2009-01-01

    An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

  13. Central nervous system lesions in adult T-cell leukaemia: MRI and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, M.; Korogi, Y.; Shigematsu, Y.; Liang, L.; Takahashi, M. [Department of Radiology, Kumamoto University School of Medicine, Honjo, Kumamoto (Japan); Matsuoka, M. [Second Division of Internal Medicine, Kumamoto University School of Medicine, Honjo, Kumamoto (Japan); Yamamoto, T. [Department of Pathology, Kumamoto University School of Medicine, Honjo, Kumamoto (Japan); Jhono, M. [Department of Dermatology, Kumamoto University School of Medicine, Honjo, Kumamoto (Japan); Eto, K. [The National Institute for Minamata Disease, Minamata (Japan)

    2002-07-01

    Adult T-cell leukaemia (ATL) is a T-cell lymphoid neoplasm caused by human T-cell leukaemia virus type I (HTLV-I). Radiological findings in central nervous system (CNS) involvement have not been well characterised. We reviewed the MRI of 18 patients with ATL who developed new neurological symptoms or signs, and pathology specimens from a 53-year-old woman who died of ATL. MRI findings were divided into three categories: definite, probable, and other abnormal. Definite and probable findings were defined as ATL-related. The characteristic findings were multiple parenchymal masses with or without contrast enhancement adjacent to cerebrospinal fluid (CSF) spaced and the deep grey matter of both cerebral hemispheres, plus leptomeningeal lesion. One patient had both cerebral and spinal cord lesions. Other abnormal findings in eight patients included one case of leukoencephalopathy caused by methotrexate. The histology findings consisted of clusters of tumour cells along perivascular spaces, and scattered infiltration of the parenchyma, with nests of tumour cells. Leptomeningeal infiltration by tumour spread into the parenchyma and secondary degeneration of the neuronal tracts was observed. MRI was useful for detecting CNS invasion by ATL and differentiating it from other abnormalities. The MRI findings seemed to correlate well with the histological changes. (orig.)

  14. Central nervous system lesions in adult T-cell leukaemia: MRI and pathology

    International Nuclear Information System (INIS)

    Kitajima, M.; Korogi, Y.; Shigematsu, Y.; Liang, L.; Takahashi, M.; Matsuoka, M.; Yamamoto, T.; Jhono, M.; Eto, K.

    2002-01-01

    Adult T-cell leukaemia (ATL) is a T-cell lymphoid neoplasm caused by human T-cell leukaemia virus type I (HTLV-I). Radiological findings in central nervous system (CNS) involvement have not been well characterised. We reviewed the MRI of 18 patients with ATL who developed new neurological symptoms or signs, and pathology specimens from a 53-year-old woman who died of ATL. MRI findings were divided into three categories: definite, probable, and other abnormal. Definite and probable findings were defined as ATL-related. The characteristic findings were multiple parenchymal masses with or without contrast enhancement adjacent to cerebrospinal fluid (CSF) spaced and the deep grey matter of both cerebral hemispheres, plus leptomeningeal lesion. One patient had both cerebral and spinal cord lesions. Other abnormal findings in eight patients included one case of leukoencephalopathy caused by methotrexate. The histology findings consisted of clusters of tumour cells along perivascular spaces, and scattered infiltration of the parenchyma, with nests of tumour cells. Leptomeningeal infiltration by tumour spread into the parenchyma and secondary degeneration of the neuronal tracts was observed. MRI was useful for detecting CNS invasion by ATL and differentiating it from other abnormalities. The MRI findings seemed to correlate well with the histological changes. (orig.)

  15. MINIPILOT SOLAR SYSTEM: DESIGN/OPERATION OF SYSTEM AND RESULTS OF NON-SOLAR TESTING AT MRI

    Science.gov (United States)

    Prior to this project, MRI had carried out work for the Environmental Protection Agency (EPA) on the conceptual design of a solar system for solid waste disposal and a follow-on project to study the feasibility of bench-scale testing of desorption of organics from soil with destr...

  16. Estimation of Pulmonary Motion in Healthy Subjects and Patients with Intrathoracic Tumors Using 3D-Dynamic MRI: Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Plathow, Christian; Schoebinger, Max; Meinzer, Heinz Peter [German Cancer Research Center, Heidelberg (Germany); Herth, Felix; Tuengerthal, Siegfried [Clinic of Thoracic Disease, Heidelberg (Germany); Kauczor, Hans Ulrich [University of Heidelberg, Heidelberg (Germany)

    2009-12-15

    To estimate a new technique for quantifying regional lung motion using 3D-MRI in healthy volunteers and to apply the technique in patients with intra- or extrapulmonary tumors. Intraparenchymal lung motion during a whole breathing cycle was quantified in 30 healthy volunteers using 3D-dynamic MRI (FLASH [fast low angle shot] 3D, TRICKS [time-resolved interpolated contrast kinetics]). Qualitative and quantitative vector color maps and cumulative histograms were performed using an introduced semiautomatic algorithm. An analysis of lung motion was performed and correlated with an established 2D-MRI technique for verification. As a proof of concept, the technique was applied in five patients with non-small cell lung cancer (NSCLC) and 5 patients with malignant pleural mesothelioma (MPM). The correlation between intraparenchymal lung motion of the basal lung parts and the 2D-MRI technique was significant (r = 0.89, p < 0.05). Also, the vector color maps quantitatively illustrated regional lung motion in all healthy volunteers. No differences were observed between both hemithoraces, which was verified by cumulative histograms. The patients with NSCLC showed a local lack of lung motion in the area of the tumor. In the patients with MPM, there was global diminished motion of the tumor bearing hemithorax, which improved significantly after chemotherapy (CHT) (assessed by the 2D- and 3D-techniques) (p < 0.01). Using global spirometry, an improvement could also be shown (vital capacity 2.9 {+-} 0.5 versus 3.4 L {+-} 0.6, FEV1 0.9 {+-} 0.2 versus 1.4 {+-} 0.2 L) after CHT, but this improvement was not significant. A 3D-dynamic MRI is able to quantify intraparenchymal lung motion. Local and global parenchymal pathologies can be precisely located and might be a new tool used to quantify even slight changes in lung motion (e.g. in therapy monitoring, follow-up studies or even benign lung diseases)

  17. Software-Based Student Response Systems: An Interdisciplinary Initiative

    Science.gov (United States)

    Fischer, Carol M.; Hoffman, Michael S.; Casey, Nancy C.; Cox, Maureen P.

    2015-01-01

    Colleagues from information technology and three academic departments collaborated on an instructional technology initiative to employ student response systems in classes in mathematics, accounting and education. The instructors assessed the viability of using software-based systems to enable students to use their own devices (cell phones,…

  18. Intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injuries.

    Science.gov (United States)

    Wangensteen, Arnlaug; Tol, Johannes L; Roemer, Frank W; Bahr, Roald; Dijkstra, H Paul; Crema, Michel D; Farooq, Abdulaziz; Guermazi, Ali

    2017-04-01

    To assess and compare the intra- and interrater reliability of three different MRI grading and classification systems after acute hamstring injury. Male athletes (n=40) with clinical diagnosis of acute hamstring injury and MRI ≤5days were selected from a prospective cohort. Two radiologists independently evaluated the MRIs using standardised scoring form including the modified Peetrons grading system, the Chan acute muscle strain injury classification and the British Athletics Muscle Injury Classification. Intra-and interrater reliability was assessed with linear weighted kappa (κ) or unweighted Cohen's κ and percentage agreement was calculated. We observed 'substantial' to 'almost perfect' intra- (κ range 0.65-1.00) and interrater reliability (κ range 0.77-1.00) with percentage agreement 83-100% and 88-100%, respectively, for severity gradings, overall anatomical sites and overall classifications for the three MRI systems. We observed substantial variability (κ range -0.05 to 1.00) for subcategories within the Chan classification and the British Athletics Muscle Injury Classification, however, the prevalence of positive scorings was low for some subcategories. The modified Peetrons grading system, overall Chan classification and overall British Athletics Muscle Injury Classification demonstrated 'substantial' to 'almost perfect' intra- and interrater reliability when scored by experienced radiologists. The intra- and interrater reliability for the anatomical subcategories within the classifications remains unclear. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  20. A graphics processing unit accelerated motion correction algorithm and modular system for real-time fMRI.

    Science.gov (United States)

    Scheinost, Dustin; Hampson, Michelle; Qiu, Maolin; Bhawnani, Jitendra; Constable, R Todd; Papademetris, Xenophon

    2013-07-01

    Real-time functional magnetic resonance imaging (rt-fMRI) has recently gained interest as a possible means to facilitate the learning of certain behaviors. However, rt-fMRI is limited by processing speed and available software, and continued development is needed for rt-fMRI to progress further and become feasible for clinical use. In this work, we present an open-source rt-fMRI system for biofeedback powered by a novel Graphics Processing Unit (GPU) accelerated motion correction strategy as part of the BioImage Suite project ( www.bioimagesuite.org ). Our system contributes to the development of rt-fMRI by presenting a motion correction algorithm that provides an estimate of motion with essentially no processing delay as well as a modular rt-fMRI system design. Using empirical data from rt-fMRI scans, we assessed the quality of motion correction in this new system. The present algorithm performed comparably to standard (non real-time) offline methods and outperformed other real-time methods based on zero order interpolation of motion parameters. The modular approach to the rt-fMRI system allows the system to be flexible to the experiment and feedback design, a valuable feature for many applications. We illustrate the flexibility of the system by describing several of our ongoing studies. Our hope is that continuing development of open-source rt-fMRI algorithms and software will make this new technology more accessible and adaptable, and will thereby accelerate its application in the clinical and cognitive neurosciences.

  1. Volumetric MRI of the limbic system: anatomic determinants

    Energy Technology Data Exchange (ETDEWEB)

    Bilir, E.; Craven, W.; Hugg, J.; Gilliam, F.; Martin, R.; Faught, E.; Kuzniecky, R. [UAB Epilepsy Center, Department of Neurology, University of Alabama at Birmingham, Birmingham, AL (United States)

    1998-03-01

    The limbic system comprises the hippocampal formation, fornix, mamillary bodies, thalamus, and other integrated structures. It is involved in complex functions including memory and emotion and in diseases such as temporal lobe epilepsy. Volume measurements of the amygdala and hippocampus have been used reliably to study patients with temporal lobe epilepsy but have not extended to other limbic structures. We performed volume measurements of hippocampus, amygdala, fornix and mamillary bodies in healthy individuals. Measurements of the amygdala, hippocampus, fornix and mamillary bodies revealed significant differences in volume between right and left sides (P < 0.001). The intraclass coefficient of variation for measurements was high for all structures except the mamillary bodies. Qualitative image assessment of the same structures revealed no asymmetries between the hemispheres. This technique can be applied to the study of disorders affecting the limbic system. (orig.) With 4 figs., 2 tabs., 23 refs.

  2. Volumetric MRI of the limbic system: anatomic determinants

    International Nuclear Information System (INIS)

    Bilir, E.; Craven, W.; Hugg, J.; Gilliam, F.; Martin, R.; Faught, E.; Kuzniecky, R.

    1998-01-01

    The limbic system comprises the hippocampal formation, fornix, mamillary bodies, thalamus, and other integrated structures. It is involved in complex functions including memory and emotion and in diseases such as temporal lobe epilepsy. Volume measurements of the amygdala and hippocampus have been used reliably to study patients with temporal lobe epilepsy but have not extended to other limbic structures. We performed volume measurements of hippocampus, amygdala, fornix and mamillary bodies in healthy individuals. Measurements of the amygdala, hippocampus, fornix and mamillary bodies revealed significant differences in volume between right and left sides (P < 0.001). The intraclass coefficient of variation for measurements was high for all structures except the mamillary bodies. Qualitative image assessment of the same structures revealed no asymmetries between the hemispheres. This technique can be applied to the study of disorders affecting the limbic system. (orig.)

  3. Functional MRI of the olfactory system in conscious dogs.

    Directory of Open Access Journals (Sweden)

    Hao Jia

    Full Text Available We depend upon the olfactory abilities of dogs for critical tasks such as detecting bombs, landmines, other hazardous chemicals and illicit substances. Hence, a mechanistic understanding of the olfactory system in dogs is of great scientific interest. Previous studies explored this aspect at the cellular and behavior levels; however, the cognitive-level neural substrates linking them have never been explored. This is critical given the fact that behavior is driven by filtered sensory representations in higher order cognitive areas rather than the raw odor maps of the olfactory bulb. Since sedated dogs cannot sniff, we investigated this using functional magnetic resonance imaging of conscious dogs. We addressed the technical challenges of head motion using a two pronged strategy of behavioral training to keep dogs' head as still as possible and a single camera optical head motion tracking system to account for residual jerky movements. We built a custom computer-controlled odorant delivery system which was synchronized with image acquisition, allowing the investigation of brain regions activated by odors. The olfactory bulb and piriform lobes were commonly activated in both awake and anesthetized dogs, while the frontal cortex was activated mainly in conscious dogs. Comparison of responses to low and high odor intensity showed differences in either the strength or spatial extent of activation in the olfactory bulb, piriform lobes, cerebellum, and frontal cortex. Our results demonstrate the viability of the proposed method for functional imaging of the olfactory system in conscious dogs. This could potentially open up a new field of research in detector dog technology.

  4. Assessment of three different software systems in the evaluation of dynamic MRI of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, K.D. [Department of Radiology, Stavanger University Hospital, Postbox 8100, Stavanger (Norway)], E-mail: kurk@sus.no; Steinhaus, D. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: Daniele.Steinhaus@med.uni-duesseldorf.de; Klar, V. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: verena.klar@uni-duesseldorf.de; Cohnen, M. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: cohnen@med.uni-duesseldorf.de; Wittsack, H.J. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: wittsack@uni-duesseldorf.de; Saleh, A. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: saleh@uni-duesseldorf.de; Moedder, U. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: moedder@med.uni-duesseldorf.de; Blondin, D. [Institute of Daignostic Radiology, Duesseldorf University Hospital, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de

    2009-02-15

    Objective: The aim was to compare the diagnostic performance and handling of dynamic contrast-enhanced MRI of the breast with two commercial software solutions ('CADstream' and '3TP') and one self-developed software system ('Mammatool'). Materials and methods: Identical data sets of dynamic breast MRI from 21 patients were evaluated retrospectively with all three software systems. The exams were classified according to the BI-RADS classification. The number of lesions in the parametric mapping was compared to histology or follow-up of more than 2 years. In addition, 25 quality criteria were judged by 3 independent investigators with a score from 0 to 5. Statistical analysis was performed to document the quality ranking of the different software systems. Results: There were 9 invasive carcinomas, one pure DCIS, one papilloma, one radial scar, three histologically proven changes due to mastopathy, one adenosis and two fibroadenomas. Additionally two patients with enhancing parenchyma followed with MRI for more than 3 years and one scar after breast conserving therapy were included. All malignant lesions were classified as BI-RADS 4 or 5 using all software systems and showed significant enhancement in the parametric mapping. 'CADstream' showed the best score on subjective quality criteria. '3TP' showed the lowest number of false-positive results. 'Mammatool' produced the lowest number of benign tissues indicated with parametric overlay. Conclusion: All three software programs tested were adequate for sensitive and efficient assessment of dynamic MRI of the breast. Improvements in specificity may be achievable.

  5. Radio frequency tags systems to initiate system processing

    Science.gov (United States)

    Madsen, Harold O.; Madsen, David W.

    1994-09-01

    This paper describes the automatic identification technology which has been installed at Applied Magnetic Corp. MR fab. World class manufacturing requires technology exploitation. This system combines (1) FluoroTrac cassette and operator tracking, (2) CELLworks cell controller software tools, and (3) Auto-Soft Inc. software integration services. The combined system eliminates operator keystrokes and errors during normal processing within a semiconductor fab. The methods and benefits of this system are described.

  6. Metastasis in the base of the cranium: initial manifestation of a hepato carcinoma. Findings in the CT and MRI

    International Nuclear Information System (INIS)

    Fernandez, M. T.; Saiz, A.; Cardenal, A.; Oruezabal, M.

    2000-01-01

    We present a case of hepato carcinoma (HC) whose first clinical manifestation was diplopia. The imaging methods showed a sold mass in the base of the cranium with meningioma characteristics. The histological study showed the existence of hepatocytes, which confirmed the diagnosis of metastasis of the HC: We present the X-ray findings in the CT and MRI of this case and the differential diagnosis with other tumors that affect the cranium base. We also perform a bibliographic review of this clinical manifestation with such an unusual X-ray. (Author) 19 refs

  7. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided....

  8. MRI and CT appearances in metabolic encephalopathies due to systemic diseases in adults

    International Nuclear Information System (INIS)

    Bathla, G.; Hegde, A.N.

    2013-01-01

    The term encephalopathy refers to a clinical scenario of diffuse brain dysfunction, commonly due to a systemic, metabolic, or toxic derangement. Often the clinical evaluation is unsatisfactory in this scenario and imaging plays an important role in the diagnosis, assessment of treatment response, and prognostication of the disorder. Hence, it is important for radiologists to be familiar with the imaging features of some relatively frequently acquired metabolic encephalopathies encountered in the hospital setting. This study reviews the computed tomography (CT) and magnetic resonance imaging (MRI) features of a number of metabolic encephalopathies that occur as part of systemic diseases in adults. The following conditions are covered in this review: hypoglycaemic encephalopathy, hypoxic ischaemic encephalopathy, non-ketotic hyperglycaemia, hepatic encephalopathy, uraemic encephalopathy, hyperammonaemic encephalopathy, and posterior reversible encephalopathy syndrome. MRI is the imaging method of choice in evaluating these conditions. Due to their high metabolic activity, bilateral basal ganglia changes are evident in the majority of cases. Concurrent imaging abnormalities in other parts of the central nervous system often provide useful diagnostic information about the likely underlying cause of the encephalopathy. Besides this, abnormal signal intensity and diffusion restriction patterns on MRI and MR spectroscopy features may provide important clues as to the diagnosis and guide further management. Frequently, the diagnosis is not straightforward and typical imaging features require correlation with clinical and laboratory data for accurate assessment

  9. Macrophage Activation Syndrome as Initial Presentation of Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Say-Tin Yeap

    2008-04-01

    Full Text Available Macrophage activation syndrome (MAS is known to be a severe and potentially life-threatening complication of rheumatic disorder, especially systemic juvenile rheumatoid arthritis. It is very rare for MAS to be an initial presentation of systemic lupus erythematosus (SLE. Here, we report a 14-year-old girl in whom MAS developed as an initial presentation of SLE. With early diagnosis and administration of cyclosporine A, she had a fair outcome. Further testing showed positive anti-dsDNA about 8 months later.

  10. A low cost fMRI-compatible tracking system using the Nintendo Wii remote.

    Science.gov (United States)

    Modroño, Cristián; Rodríguez-Hernández, Antonio F; Marcano, Francisco; Navarrete, Gorka; Burunat, Enrique; Ferrer, Marta; Monserrat, Raquel; González-Mora, José L

    2011-11-15

    It is sometimes necessary during functional magnetic resonance imaging (fMRI) experiments to capture different movements made by the subjects, e.g. to enable them to control an item or to analyze its kinematics. The aim of this work is to present an inexpensive hand tracking system suitable for use in a high field MRI environment. It works by introducing only one light-emitting diode (LED) in the magnet room, and by receiving its signal with a Nintendo Wii remote (the primary controller for the Nintendo Wii console) placed outside in the control room. Thus, it is possible to take high spatial and temporal resolution registers of a moving point that, in this case, is held by the hand. We tested it using a ball and racket virtual game inside a 3 Tesla MRI scanner to demonstrate the usefulness of the system. The results show the involvement of a number of areas (mainly occipital and frontal, but also parietal and temporal) when subjects are trying to stop an object that is approaching from a first person perspective, matching previous studies performed with related visuomotor tasks. The system presented here is easy to implement, easy to operate and does not produce important head movements or artifacts in the acquired images. Given its low cost and ready availability, the method described here is ideal for use in basic and clinical fMRI research to track one or more moving points that can correspond to limbs, fingers or any other object whose position needs to be known. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. MRI-compatible audio/visual system: impact on pediatric sedation

    International Nuclear Information System (INIS)

    Harned, R.K. II; Strain, J.D.

    2001-01-01

    Background. While sedation is necessary for much pediatric imaging, there are new alternatives that may help patients hold still without medication. Objective. We examined the effect of an audio/visual system consisting of video goggles and earphones on the need for sedation during magnetic resonance imaging (MRI). Materials and methods. All MRI examinations from May 1999 to October 1999 performed after installation of the MRVision 2000 (Resonance Technology, Inc.) were compared to the same 6-month period in 1998. Imaging and sedation protocols remained constant. Data collected included: patient age, type of examination, use of intravenous contrast enhancement, and need for sedation. The average supply charge and nursing cost per sedated patient were calculated. Results. The 955 patients from 1998 and 1,112 patients from 1999 were similar in demographics and examination distribution. There was an overall reduction in the percent of patients requiring sedation in the group using the video goggle system from 49 to 40 % (P < 0.001). There was no significant change for 0-2 years (P = 0.805), but there was a reduction from 53 to 40 % for age 3-10 years (P < 0.001) and 16 to 8 % for those older than 10 years (P < 0.001). There was a 17 % decrease in MRI room time for those patients whose examinations could be performed without sedation. Sedation costs per patient were $80 for nursing and $29 for supplies. Conclusion. The use of this video system reduced the number of children requiring sedation for MRI examination by 18 %. In addition to reducing patient risk, this can potentially reduce cost. (orig.)

  12. MRI findings in central nervous system of neurofibromatosis-II

    International Nuclear Information System (INIS)

    Chen Maoen; Huang Suiqiao; Shen Jun; Hong Guobin; Wu Zhuo; Lin Xiaofeng

    2007-01-01

    Objective: To investigate the diagnostic value of MR imaging in central nervous system involvement of neurofibromatosis II. Methods: 7 patients with surgically and pathologically proved neurofibromatosis II were included. Their MR imaging findings and clinical features were retrospectively analyzed. Results: The main findings of 7 cases of neurofibraomaosis II on MR imaging included bilateral acoustic neurilemoma, multiple neurofibroma, meningioma and schwannoma. Among the 7 patients, Tl-weighted imaging after contrast enhancement displayed additional lesions which had been ignored on un-enhanced scan. Conclusion: MR imaging has advantages in the detection of central nervous sys- tem involvement of neurofibromatosis II with regard to its ability to show the lesions well, meanwhile displaying the size, morphology and signal features clearly. (authors)

  13. A novel optically transparent RF shielding for fully integrated PET/MRI systems

    Science.gov (United States)

    Parl, C.; Kolb, A.; Schmid, A. M.; Wehrl, H. F.; Disselhorst, J. A.; Soubiran, P. D.; Stricker-Shaver, D.; Pichler, B. J.

    2017-09-01

    Preclinical imaging benefits from simultaneous acquisition of high-resolution anatomical and molecular data. Additionally, PET/MRI systems can provide functional PET and functional MRI data. To optimize PET sensitivity, we propose a system design that fully integrates the MRI coil into the PET system. This allows positioning the scintillators near the object but requires an optimized design of the MRI coil and PET detector. It further requires a new approach in realizing the radiofrequency (RF) shielding. Thus, we propose the use of an optically transparent RF shielding material between the PET scintillator and the light sensor, suppressing the interference between both systems. We evaluated two conductive foils (ITO, 9900) and a wire mesh. The PET performance was tested on a dual-layer scintillator consisting of 12  ×  12 LSO matrices, shifted by half a pitch. The pixel size was 0.9  ×  0.9 mm2 the lengths were 10.0 mm and 5.0 mm, respectively. For a light sensor, we used a 4  ×  4 SiPM array. The RF attenuation was measured from 320 kHz to 420 MHz using two pick-up coils. MRI-compatibility and shielding effect of the materials were evaluated with an MRI system. The average FWHM energy resolution at 511 keV of all 144 crystals of the layer next to the SiPM was deteriorated from 15.73  ±  0.24% to 16.32  ±  0.13%, 16.60  ±  0.25%, and 19.16  ±  0.21% by the ITO foil, 9900 foil, mesh material, respectively. The average peak-to-valley ratio of the PET detector changed from 5.77  ±  0.29 to 4.50  ±  0.39, 4.78  ±  0.48, 3.62  ±  0.16, respectively. The ITO, 9900, mesh attenuated the scintillation light by 11.3  ±  1.6%, 11.0  ±  1.8%, 54.3  ±  0.4%, respectively. To attenuate the RF from 20 MHz to 200 MHz, mesh performed better than copper. The results show that an RF shielding material that is sufficiently transparent for

  14. Microcomputer-based image processing system for CT/MRI scans II

    International Nuclear Information System (INIS)

    Kwok, J.C.K.; Yu, P.K.N.; Cheng, A.Y.S.; Ho, W.C.

    1991-01-01

    This paper reports that a microcomputer-based image processing system is used to digitize and process serial sections of CT/MRI scan and reconstruct three-dimensional images of brain structures and brain lesions. The images grabbed also serve as templates and different vital regions with different risk values are also traced out for 3D reconstruction. A knowledge-based system employing rule-based programming has been built to help identifying brain lesions and to help planning trajectory for operations. The volumes of the lesions are also automatically determined. Such system is very useful for medical skills archival, tumor size monitoring, survival and outcome forecasting, and consistent neurosurgical planning

  15. Spiral Gradient Coil Design for Use in Cylindrical MRI Systems.

    Science.gov (United States)

    Wang, Yaohui; Xin, Xuegang; Liu, Feng; Crozier, Stuart

    2018-04-01

    In magnetic resonance imaging, the stream function based method is commonly used in the design of gradient coils. However, this method can be prone to errors associated with the discretization of continuous current density and wire connections. In this paper, we propose a novel gradient coil design scheme that works directly in the wire space, avoiding the system errors that may appear in the stream function approaches. Specifically, the gradient coil pattern is described with dedicated spiral functions adjusted to allow the coil to produce the required field gradients in the imaging area, minimal stray field, and other engineering terms. The performance of a designed spiral gradient coil was compared with its stream-function counterpart. The numerical evaluation shows that when compared with the conventional solution, the inductance and resistance was reduced by 20.9 and 10.5%, respectively. The overall coil performance (evaluated by the figure of merit (FoM)) was improved up to 26.5% for the x -gradient coil design; for the z-gradient coil design, the inductance and resistance were reduced by 15.1 and 6.7% respectively, and the FoM was increased by 17.7%. In addition, by directly controlling the wire distributions, the spiral gradient coil design was much sparser than conventional coils.

  16. Selection of initial events of accelerator driven subcritical system

    International Nuclear Information System (INIS)

    Wang Qianglong; Hu Liqin; Wang Jiaqun; Li Yazhou; Yang Zhiyi

    2013-01-01

    The Probabilistic Safety Assessment (PSA) is an important tool in reactor safety analysis and a significant reference to the design and operation of reactor. It is the origin and foundation of the PSA for a reactor to select the initial events. Accelerator Driven Subcritical System (ADS) has advanced design characteristics, complicated subsystems and little engineering and operating experience, which makes it much more difficult to identify the initial events of ADS. Based on the current design project of ADS, the system's safety characteristics and special issues were analyzed in this article. After a series of deductions with Master Logic Diagram (MLD) and considering the relating experience of other advanced research reactors, a preliminary initial events was listed finally, which provided the foundation for the next safety assessment. (authors)

  17. MRI compatibility study of an integrated PET/RF-coil prototype system at 3 T

    Science.gov (United States)

    Akram, Md Shahadat Hossain; Obata, Takayuki; Suga, Mikio; Nishikido, Fumihiko; Yoshida, Eiji; Saito, Kazuyuki; Yamaya, Taiga

    2017-10-01

    We have been working on the development of a PET insert for existing magnetic resonance imaging (MRI) systems for simultaneous PET/MR imaging, which integrates radiofrequency (RF)-shielded PET detector modules with an RF head coil. In order to avoid interferences between the PET detector circuits and the different MRI-generated electromagnetic fields, PET detector circuits were installed inside eight Cu-shielded fiber-reinforced plastic boxes, and these eight shielded PET modules were integrated in between the eight elements of a 270-mm-diameter and 280-mm-axial-length cylindrical birdcage RF coil, which was designed to be used with a 3-T clinical MRI system. The diameter of the PET scintillators with a 12-mm axial field-of-view became 255 mm, which was very close to the imaging region. In this study, we have investigated the effects of this PET/RF-coil integrated system on the performance of MRI, which include the evaluation of static field (Bo) inhomogeneity, RF field (B1) distribution, local specific absorption rate (SAR) distribution, average SAR, and signal-to-noise ratio (SNR). For the central 170-mm-diameter and 80-mm-axial-length of a homogenous cylindrical phantom (with the total diameter of 200 mm and axial-length of 100 mm), an increase of about a maximum of 3 μT in the Bo inhomogeneity was found, both in the central and 40-mm off-centered transverse planes, and a 5 percentage point increase of B1 field inhomogeneity was observed in the central transverse plane (from 84% without PET to 79% with PET), while B1 homogeneity along the coronal plane was almost unchanged (77%) following the integration of PET with the RF head coil. The average SAR and maximum local SAR were increased by 1.21 and 1.62 times, respectively. However, the SNR study for both spin-echo and gradient-echo sequences showed a reduction of about 70% and 60%, respectively, because of the shielded PET modules. The overall results prove the feasibility of this integrated PET/RF-coil system

  18. [Utilization of polymeric micelle magnetic resonance imaging (MRI) contrast agent for theranostic system].

    Science.gov (United States)

    Shiraishi, Kouichi

    2013-01-01

    We applied a polymeric micelle carrier system for the targeting of a magnetic resonance imaging (MRI) contrast agent. Prepared polymeric micelle MRI contrast agent exhibited a long circulation characteristic in blood, and considerable amount of the contrast agent was found to accumulate in colon 26 solid tumor by the EPR effect. The signal intensities of tumor area showed 2-folds increase in T1-weighted images at 24 h after i.v. injection. To observe enhancement of the EPR effect by Cderiv pretreatment on tumor targeting, we used the contrast agent for the evaluation by means of MRI. Cderiv pretreatment significantly enhanced tumor accumulation of the contrast agent. Interestingly, very high signal intensity in tumor region was found at 24 h after the contrast agent injection in Cderiv pretreated mice. The contrast agent visualized a microenvironmental change in tumor. These results indicate that the contrast agent exhibits potential use for tumor diagnostic agent. To combine with a polymeric micelle carrier system for therapeutic agent, the usage of the combination makes a new concept of "theranostic" for a better cancer treatment.

  19. PET/MRI of central nervous system: current status and future perspective

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhen Lu; Zhang, Long Jiang [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2016-10-15

    Imaging plays an increasingly important role in the early diagnosis, prognosis prediction and therapy response evaluation of central nervous system (CNS) diseases. The newly emerging hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) can perform ''one-stop-shop'' evaluation, including anatomic, functional, biochemical and metabolic information, even at the molecular level, for personalised diagnoses and treatments of CNS diseases. However, there are still several problems to be resolved, such as appropriate PET detectors, attenuation correction and so on. This review will introduce the basic physical principles of PET/MRI and its potential clinical applications in the CNS. We also provide the future perspectives for this field. (orig.)

  20. CT of the musculoskeletal system: What is left is the days of MRI?

    International Nuclear Information System (INIS)

    West, A.T.H.; Marshall, T.J.; Bearcroft, P.W.

    2009-01-01

    Magnetic resonance imaging (MRI) plays a central role in the modern imaging of musculoskeletal disorders, due to its ability to produce multiplanar images and characterise soft tissues accurately. However, computed tomography (CT) still has an important role to play, not merely as an alternative to MRI, but as being the preferred imaging investigation in some situations. This article briefly reviews the history of CT technology, the technical factors involved and a number of current applications, as well as looking at future areas where CT may be employed. The advent of ever-increasing numbers of rows of detectors has opened up more possible uses for CT technology. However, diagnostic images may be obtained from CT systems with four rows of detectors or more, and their ability to produce near isotropic voxels and therefore multiplanar reformats. (orig.)

  1. Semilinear hyperbolic systems and equations with singular initial data

    International Nuclear Information System (INIS)

    Gramchev, T.

    1991-07-01

    We study the weak limits of solutions u ε (t, ·) for ε→0 to semilinear strictly hyperbolic systems and wave equations with initial data u ε (0, ·) approximating a distribution κ, 0 ε (t, ·) for ε→0 exists. 13 refs

  2. Initial Single-Shell Tank Retrieval System mission analysis report

    International Nuclear Information System (INIS)

    Hertzel, J.S.

    1996-03-01

    This document provides the mission analysis for the Initial Single-Shell Tank Retrieval System task, which supports the Single-Shell Tank Waste Retrieval Program in its commitment to remove waste from single-shell tanks for treatment and final closure

  3. STUDIES ON VINYL POLYMERIZATION WITH INITIATION SYSTEM CONTAINING AMINE DERIVATIVES

    Institute of Scientific and Technical Information of China (English)

    QIU Kunyuan; ZHANG Jingyi; FENG Xinde(S. T. Voong)

    1983-01-01

    Two main types of amine-containing initiation systems were studied in this work. In the case of MMA polymerization initiated by BPO-amine (DMT, DHET, DMA) redox systems, it was found that the polymerization rate and colour stability of the polymer for different amine systems were in the following order: DMT≈DHET>DMA. Accordingly, BPO-DMT and BPO-DHET are effective initiators. In the case of MEMA polymerization by amine (DMT, DHET, DMA) alone, it was found that the polymerization rate and the percentage of conversion for these different amine systems were in the following order: DMT≥DHET>DMA. The polymerization rate and the percentage of conversion also increased with the increase of DMT concentration. From the kinetic investigation the rate equation of Rp=K [DMT]1/2 [MEMA]3/2 was obtained, and the overall activation energy of polymerization was calculated to be 34.3 KJ/mol (8.2 Kcal/mol). Moreover, the polymerization of MEMA in the presence of DMT was strongly inhibited by hydroquinone, indicating the polymerization being free radical in nature. From these results, the mechanism of MEMA polymerization initiated by amine was proposed.

  4. Management Control System Support of Initiatives for Disruptive Students

    Science.gov (United States)

    Scott, Colin

    2011-01-01

    Purpose: The purpose of the paper is to investigate the management control system (MCS) support of school initiatives to develop the school climate and to re-engage disruptive students. Design/methodology/approach: The paper adopts an approach of critical action research interviews with management and document reviews informed by Habermasian…

  5. Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Tanja [Ludwig-Maximilians-University Munich, Department of Clinical Radiology, Munich (Germany); Ludwig-Maximilians-University Munich, Department of Clinical Radiology, Klinikum Innenstadt, Munich (Germany); Ladurner, Roland; Mussack, Thomas [Ludwig-Maximilians-University Munich, Department of Surgery and Traumatology, Klinikum Innenstadt, Munich (Germany); Gangkofer, Alexander; Reiser, Maximilian; Lienemann, Andreas [Ludwig-Maximilians-University Munich, Department of Clinical Radiology, Munich (Germany)

    2007-12-15

    The aim of our study was to develop a method that allows the vizualiation and evaluation of implanted mesh in patients after incisional hernia repair with MRI. Furthermore, we assessed problems typically related with mesh implantation like adhesions and muscular atrophy. We enrolled 28 patients after incisional hernia repair. In 10 patients mesh implantation was done by laparoscopy (expanded polytetrafluoroethylene=ePTFE mesh) and in 18 by laparotomy (polypropylene mesh). Functional MRI was performed on a 1.5-T system in supine position. Sagittal and axial TrueFISP images of the entire abdomen were acquired with the patient repeatedly straining. Evaluation included: correct position and intact fixation of the mesh, furthermore visceral adhesions, recurrent hernia and atrophy of the rectus muscle. The ePTFE mesh was visible in all cases; the polypropylene mesh was not detectable. In seven of the ten ePTFE meshes the fixation was not intact; two recurrent hernias were detected. Twenty of 28 patients had intraabdominal adhesions. In 5 cases mobility of the abdominal wall was reduced, and 16 patients showed an atropy of the rectus muscle. Functional cine MRI is a suitable method for follow-up studies in patients after hernia repair. ePTFE meshes can be visualized directly, and typical complications like intestinal adhesions and abdominal wall dysmotility can be assessed reliably. (orig.)

  6. KneeTex: an ontology-driven system for information extraction from MRI reports.

    Science.gov (United States)

    Spasić, Irena; Zhao, Bo; Jones, Christopher B; Button, Kate

    2015-01-01

    In the realm of knee pathology, magnetic resonance imaging (MRI) has the advantage of visualising all structures within the knee joint, which makes it a valuable tool for increasing diagnostic accuracy and planning surgical treatments. Therefore, clinical narratives found in MRI reports convey valuable diagnostic information. A range of studies have proven the feasibility of natural language processing for information extraction from clinical narratives. However, no study focused specifically on MRI reports in relation to knee pathology, possibly due to the complexity of knee anatomy and a wide range of conditions that may be associated with different anatomical entities. In this paper we describe KneeTex, an information extraction system that operates in this domain. As an ontology-driven information extraction system, KneeTex makes active use of an ontology to strongly guide and constrain text analysis. We used automatic term recognition to facilitate the development of a domain-specific ontology with sufficient detail and coverage for text mining applications. In combination with the ontology, high regularity of the sublanguage used in knee MRI reports allowed us to model its processing by a set of sophisticated lexico-semantic rules with minimal syntactic analysis. The main processing steps involve named entity recognition combined with coordination, enumeration, ambiguity and co-reference resolution, followed by text segmentation. Ontology-based semantic typing is then used to drive the template filling process. We adopted an existing ontology, TRAK (Taxonomy for RehAbilitation of Knee conditions), for use within KneeTex. The original TRAK ontology expanded from 1,292 concepts, 1,720 synonyms and 518 relationship instances to 1,621 concepts, 2,550 synonyms and 560 relationship instances. This provided KneeTex with a very fine-grained lexico-semantic knowledge base, which is highly attuned to the given sublanguage. Information extraction results were evaluated

  7. A Tumor-Targeted Nanodelivery System to Improve Early MRI Detection of Cancer

    Directory of Open Access Journals (Sweden)

    Kathleen F. Pirollo

    2006-01-01

    Full Text Available The development of improvements in magnetic resonance imaging (MRI that would enhance sensitivity, leading to earlier detection of cancer and visualization of metastatic disease, is an area of intense exploration. We have devised a tumor-targeting, liposomal nanodelivery platform for use in gene medicine. This systemically administered nanocomplex has been shown to specifically and efficiently deliver both genes and oligonucleotides to primary and metastatic tumor cells, resulting in significant tumor growth inhibition and even tumor regression. Here we examine the effect on MRI of incorporating conventional MRI contrast agent Magnevist® into our anti-transferrin receptor single-chain antibody (TfRscFv liposomal complex. Both in vitro and in an in vivo orthotopic mouse model of pancreatic cancer, we show increased resolution and image intensity with the complexed Magnevist®. Using advanced microscopy techniques (scanning electron microscopy and scanning probe microscopy, we also established that the Magnevist® is in fact encapsulated by the liposome in the complex and that the complex still retains its nanodimensional size. These results demonstrate that this TfRscFv-liposome-Magnevist® nanocomplex has the potential to become a useful tool in early cancer detection.

  8. MR-guided discography using an open 1 Tesla MRI system

    International Nuclear Information System (INIS)

    Streitparth, Florian; Bucourt, M. de; Hamm, B.; Teichgraeber, U.; Hartwig, T.; Strube, P.; Putzier, M.; Schnackenburg, B.; Chopra, S.

    2011-01-01

    To evaluate the feasibility of MR-guided discography using an open 1 Tesla MRI system. 48 disc segments of 41 patients scheduled for intradiscal thermal treatment, total disc replacement or spondylodesis were examined. A 1.0-T open MRI was used for instrument guidance and imaging. After primary disc puncture under guidance of interactive PDw TSE imaging, 1-2 ml of gadolinium contrast saline mixture was injected into the disc. The occurrence of memory pain during injection was recorded. Axial and sagittal T1w TSE images with and without fat saturation were obtained. All MRI discograms were analysed by two readers, who were blinded to the clinical findings. Overall, the placement of the puncture needle in the targeted disc was accurate under real-time MR guidance. Injections were technically successful in all cases. No major complications occurred. The mean procedure time was 17 min (range 13-34 min). Image quality of contrast-enhanced MR discograms was excellent when using an optimized gadolinium contrast saline mixture of 1:600. Memory pain was detected in 16 out of 48 affected segments. MR-guided discography is accurate and safe. Multiplanar dynamic imaging facilitates the puncture of discs and provides high-quality MR discograms. (orig.)

  9. Multiple fMRI system-level baseline connectivity is disrupted in patients with consciousness alterations.

    Science.gov (United States)

    Demertzi, Athena; Gómez, Francisco; Crone, Julia Sophia; Vanhaudenhuyse, Audrey; Tshibanda, Luaba; Noirhomme, Quentin; Thonnard, Marie; Charland-Verville, Vanessa; Kirsch, Murielle; Laureys, Steven; Soddu, Andrea

    2014-03-01

    In healthy conditions, group-level fMRI resting state analyses identify ten resting state networks (RSNs) of cognitive relevance. Here, we aim to assess the ten-network model in severely brain-injured patients suffering from disorders of consciousness and to identify those networks which will be most relevant to discriminate between patients and healthy subjects. 300 fMRI volumes were obtained in 27 healthy controls and 53 patients in minimally conscious state (MCS), vegetative state/unresponsive wakefulness syndrome (VS/UWS) and coma. Independent component analysis (ICA) reduced data dimensionality. The ten networks were identified by means of a multiple template-matching procedure and were tested on neuronality properties (neuronal vs non-neuronal) in a data-driven way. Univariate analyses detected between-group differences in networks' neuronal properties and estimated voxel-wise functional connectivity in the networks, which were significantly less identifiable in patients. A nearest-neighbor "clinical" classifier was used to determine the networks with high between-group discriminative accuracy. Healthy controls were characterized by more neuronal components compared to patients in VS/UWS and in coma. Compared to healthy controls, fewer patients in MCS and VS/UWS showed components of neuronal origin for the left executive control network, default mode network (DMN), auditory, and right executive control network. The "clinical" classifier indicated the DMN and auditory network with the highest accuracy (85.3%) in discriminating patients from healthy subjects. FMRI multiple-network resting state connectivity is disrupted in severely brain-injured patients suffering from disorders of consciousness. When performing ICA, multiple-network testing and control for neuronal properties of the identified RSNs can advance fMRI system-level characterization. Automatic data-driven patient classification is the first step towards future single-subject objective diagnostics

  10. TU-H-BRA-05: A System Design for Integration of An Interior MRI and a Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Mao, W [UT Southwestern Medical Center, Dallas, TX (United States); Henry Ford Hospital, Detroit, MI (United States); Wang, G [Rensselaer Polytechnic Instit., Troy, NY (United States)

    2016-06-15

    Purpose: MRI is a highly desirable modality to guide radiation therapy but it is difficult to combine a conventional MRI scanner directly with a linear accelerator (linac). An interior MRI (iMRI) concept has been proposed to acquire MRI images within a small field of view only covering targets and immediate surrounding tissues. The objective of this project is to design an interior MRI system to work with a linac using a magnet to provide a field around 0.2T in a cube of 20cm per side, and perform image reconstruction with a slightly inhomogeneous static magnetic fields. Methods: All the results are simulated using a commercially available software package, FARADY. In our design, a ring structure holds the iMRI system and also imbeds a linac treatment head. The ring is synchronized to the linac gantry rotation. Half of the ring is made of steel and becomes a magnetic flux return path (yoke) so that a strong magnetic field will be limited inside the iron circuit and fringe fields will be very weak. In order to increase the static magnetic field homogeneity, special steel magnet boots or tips were simulated. Three curved boots were designed based on two-dimensional curves: arc, parabola and hyperbola. Results: Different boot surfaces modify magnetic field distributions differently. With the same pair of neodymium-iron-boron (NdFeB) magnets, the magnetic induction at the centers are 0.217T, 0.201T, 0.204T, and 0.212T for flat, arc, parabola and hyperbola boots, respectively. The hyperbola boots lead to the most homogeneous results, the static magnetic field deviations are within 0.5% in a cube of 20cm, and can be further improved using shimming techniques. Conclusion: This study supports the concept of an iMRI design. Successful development of iMRI will provide crucial information for tumor delineation in radiation therapy.

  11. TU-H-BRA-05: A System Design for Integration of An Interior MRI and a Linear Accelerator

    International Nuclear Information System (INIS)

    Mao, W; Wang, G

    2016-01-01

    Purpose: MRI is a highly desirable modality to guide radiation therapy but it is difficult to combine a conventional MRI scanner directly with a linear accelerator (linac). An interior MRI (iMRI) concept has been proposed to acquire MRI images within a small field of view only covering targets and immediate surrounding tissues. The objective of this project is to design an interior MRI system to work with a linac using a magnet to provide a field around 0.2T in a cube of 20cm per side, and perform image reconstruction with a slightly inhomogeneous static magnetic fields. Methods: All the results are simulated using a commercially available software package, FARADY. In our design, a ring structure holds the iMRI system and also imbeds a linac treatment head. The ring is synchronized to the linac gantry rotation. Half of the ring is made of steel and becomes a magnetic flux return path (yoke) so that a strong magnetic field will be limited inside the iron circuit and fringe fields will be very weak. In order to increase the static magnetic field homogeneity, special steel magnet boots or tips were simulated. Three curved boots were designed based on two-dimensional curves: arc, parabola and hyperbola. Results: Different boot surfaces modify magnetic field distributions differently. With the same pair of neodymium-iron-boron (NdFeB) magnets, the magnetic induction at the centers are 0.217T, 0.201T, 0.204T, and 0.212T for flat, arc, parabola and hyperbola boots, respectively. The hyperbola boots lead to the most homogeneous results, the static magnetic field deviations are within 0.5% in a cube of 20cm, and can be further improved using shimming techniques. Conclusion: This study supports the concept of an iMRI design. Successful development of iMRI will provide crucial information for tumor delineation in radiation therapy.

  12. Could new reconstruction CT techniques challenge MRI for the detection of brain metastases in the context of initial lung cancer staging?

    Energy Technology Data Exchange (ETDEWEB)

    Millon, Domitille; Byl, David; Coche, Emmanuel E. [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Cliniques Universitaires Saint Luc, Brussels (Belgium); Collard, Philippe [Universite Catholique de Louvain, Department of Pneumology, Cliniques Universitaires Saint Luc, Brussels (Belgium); Cambier, Samantha E.; Maanen, Aline G. van [Universite Catholique de Louvain, Statistic Unit, King Albert II Cancer Institute, Brussels (Belgium); Vlassenbroek, Alain [Philips Healthcare, Brussels (Belgium)

    2018-02-15

    To evaluate the diagnostic performance of brain CT images reconstructed with a model-based iterative algorithm performed at usual and reduced dose. 115 patients with histologically proven lung cancer were prospectively included over 15 months. Patients underwent two CT acquisitions at the initial staging, performed on a 256-slice MDCT, at standard (CTDIvol: 41.4 mGy) and half dose (CTDIvol: 20.7 mGy). Both image datasets were reconstructed with filtered back projection (FBP) and iterative model-based reconstruction (IMR) algorithms. Brain MRI was considered as the reference. Two blinded independent readers analysed the images. Ninety-three patients underwent all examinations. At the standard dose, eight patients presented 17 and 15 lesions on IMR and FBP CT images, respectively. At half-dose, seven patients presented 15 and 13 lesions on IMR and FBP CT images, respectively. The test could not highlight any significant difference between the standard dose IMR and the half-dose FBP techniques (p-value = 0.12). MRI showed 46 metastases on 11 patients. Specificity, negative and positive predictive values were calculated (98.9-100 %, 93.6-94.6 %, 75-100 %, respectively, for all CT techniques). No significant difference could be demonstrated between the two CT reconstruction techniques. (orig.)

  13. A fully automated system for quantification of background parenchymal enhancement in breast DCE-MRI

    Science.gov (United States)

    Ufuk Dalmiş, Mehmet; Gubern-Mérida, Albert; Borelli, Cristina; Vreemann, Suzan; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    Background parenchymal enhancement (BPE) observed in breast dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been identified as an important biomarker associated with risk for developing breast cancer. In this study, we present a fully automated framework for quantification of BPE. We initially segmented fibroglandular tissue (FGT) of the breasts using an improved version of an existing method. Subsequently, we computed BPEabs (volume of the enhancing tissue), BPErf (BPEabs divided by FGT volume) and BPErb (BPEabs divided by breast volume), using different relative enhancement threshold values between 1% and 100%. To evaluate and compare the previous and improved FGT segmentation methods, we used 20 breast DCE-MRI scans and we computed Dice similarity coefficient (DSC) values with respect to manual segmentations. For evaluation of the BPE quantification, we used a dataset of 95 breast DCE-MRI scans. Two radiologists, in individual reading sessions, visually analyzed the dataset and categorized each breast into minimal, mild, moderate and marked BPE. To measure the correlation between automated BPE values to the radiologists' assessments, we converted these values into ordinal categories and we used Spearman's rho as a measure of correlation. According to our results, the new segmentation method obtained an average DSC of 0.81 0.09, which was significantly higher (p<0.001) compared to the previous method (0.76 0.10). The highest correlation values between automated BPE categories and radiologists' assessments were obtained with the BPErf measurement (r=0.55, r=0.49, p<0.001 for both), while the correlation between the scores given by the two radiologists was 0.82 (p<0.001). The presented framework can be used to systematically investigate the correlation between BPE and risk in large screening cohorts.

  14. Initial airworthiness determining the acceptability of new airborne systems

    CERN Document Server

    Gratton, Guy

    2015-01-01

    Designed as an introduction for both advanced students in aerospace engineering and existing aerospace engineers, this book covers both engineering theory and professional practice in establishing the airworthiness of new and modified aircraft. Initial Airworthiness includes information on: ·         how structural, handling, and systems evaluations are carried out; ·         the processes by which safety and fitness for purpose are determined; and ·         the use of both US and European unit systems Covering both civil and military practice and the current regulations and standards across Europe and North America, Initial Airworthiness will give the reader an understanding of how all the major aspects of an aircraft are certified, as well as providing a valuable source of reference for existing practitioners.

  15. DCE-MRI of hepatocellular carcinoma: perfusion quantification with Tofts model versus shutter-speed model--initial experience.

    Science.gov (United States)

    Jajamovich, Guido H; Huang, Wei; Besa, Cecilia; Li, Xin; Afzal, Aneela; Dyvorne, Hadrien A; Taouli, Bachir

    2016-02-01

    To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.

  16. Systems Analysis Initiated for All-Electric Aircraft Propulsion

    Science.gov (United States)

    Kohout, Lisa L.

    2003-01-01

    A multidisciplinary effort is underway at the NASA Glenn Research Center to develop concepts for revolutionary, nontraditional fuel cell power and propulsion systems for aircraft applications. There is a growing interest in the use of fuel cells as a power source for electric propulsion as well as an auxiliary power unit to substantially reduce or eliminate environmentally harmful emissions. A systems analysis effort was initiated to assess potential concepts in an effort to identify those configurations with the highest payoff potential. Among the technologies under consideration are advanced proton exchange membrane (PEM) and solid oxide fuel cells, alternative fuels and fuel processing, and fuel storage. Prior to this effort, the majority of fuel cell analysis done at Glenn was done for space applications. Because of this, a new suite of models was developed. These models include the hydrogen-air PEM fuel cell; internal reforming solid oxide fuel cell; balance-of-plant components (compressor, humidifier, separator, and heat exchangers); compressed gas, cryogenic, and liquid fuel storage tanks; and gas turbine/generator models for hybrid system applications. Initial mass, volume, and performance estimates of a variety of PEM systems operating on hydrogen and reformate have been completed for a baseline general aviation aircraft. Solid oxide/turbine hybrid systems are being analyzed. In conjunction with the analysis efforts, a joint effort has been initiated with Glenn s Computer Services Division to integrate fuel cell stack and component models with the visualization environment that supports the GRUVE lab, Glenn s virtual reality facility. The objective of this work is to provide an environment to assist engineers in the integration of fuel cell propulsion systems into aircraft and provide a better understanding of the interaction between system components and the resulting effect on the overall design and performance of the aircraft. Initially, three

  17. African Health Systems Initiative (AHSI) | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The African Health Systems Initiative (AHSI) is a 10-year Canadian International Development Agency (CIDA)-supported program for strengthening African-led ... Le nouveau site Web et la nouvelle bibliothèque de ressources aideront à améliorer les systèmes d'information et d'enregistrement des faits d'état civil dans les ...

  18. Integrated navigation and control software system for MRI-guided robotic prostate interventions.

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S; DiMaio, Simon P; Gobbi, David G; Csoma, Csaba; Mewes, Philip W; Fichtinger, Gabor; Tempany, Clare M; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called "workphases" that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Multi-Channel RF System for MRI-Guided Transurethral Ultrasound Thermal Therapy

    Science.gov (United States)

    Yak, Nicolas; Asselin, Matthew; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound thermal therapy is an approach to treating localized prostate cancer which targets precise deposition of thermal energy within a confined region of the gland. This treatment requires a system incorporating a heating applicator with multiple planar ultrasound transducers and associated RF electronics to control individual elements independently in order to achieve accurate 3D treatment. We report the design, construction, and characterization of a prototype multi-channel system capable of controlling 16 independent RF signals for a 16-element heating applicator. The main components are a control computer, microcontroller, and a 16-channel signal generator with 16 amplifiers, each incorporating a low-pass filter and transmitted/reflected power detection circuit. Each channel can deliver from 0.5 to 10 W of electrical power and good linearity from 3 to 12 MHz. Harmonic RF signals near the Larmor frequency of a 1.5 T MRI were measured to be below -30 dBm and heating experiments within the 1.5 T MR system showed no significant decrease in SNR of the temperature images. The frequency and power for all 16 channels could be changed in less than 250 ms, which was sufficiently rapid for proper performance of the control algorithms. A common backplane design was chosen which enabled an inexpensive, modular approach for each channel resulting in an overall system with minimal footprint.

  20. Integrated navigation and control software system for MRI-guided robotic prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Fischer, Gregory S.; DiMaio, Simon P.; Gobbi, David G.; Csoma, Csaba; Mewes, Philip W.; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2010-01-01

    A software system to provide intuitive navigation for MRI-guided robotic transperineal prostate therapy is presented. In the system, the robot control unit, the MRI scanner, and the open-source navigation software are connected together via Ethernet to exchange commands, coordinates, and images using an open network communication protocol, OpenIGTLink. The system has six states called “workphases” that provide the necessary synchronization of all components during each stage of the clinical workflow, and the user interface guides the operator linearly through these workphases. On top of this framework, the software provides the following features for needle guidance: interactive target planning; 3D image visualization with current needle position; treatment monitoring through real-time MR images of needle trajectories in the prostate. These features are supported by calibration of robot and image coordinates by fiducial-based registration. Performance tests show that the registration error of the system was 2.6 mm within the prostate volume. Registered real-time 2D images were displayed 1.97 s after the image location is specified. PMID:19699057

  1. Evaluation of femoral perfusion using dynamic contrast-enhanced MRI after simultaneous initiation of electrical stimulation and steroid treatment in an osteonecrosis model.

    Science.gov (United States)

    Yamamoto, Hiroki; Ueshima, Keiichiro; Saito, Masazumi; Ikoma, Kazuya; Ishida, Masashi; Goto, Tsuyoshi; Hayashi, Shigeki; Ikegami, Akira; Fujioka, Mikihiro; Mazda, Osam; Kubo, Toshikazu

    2018-04-30

    This study aimed to evaluate femoral perfusion using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for two weeks after the simultaneous initiation of electrical stimulation (ES) and steroid treatment in a steroid-induced osteonecrosis (ON) model. A single dose of methylprednisolone was injected into 14 rabbits. Seven rabbits underwent ES (ES group), and seven rabbits did not (control group). DCE-MRI was performed before steroid administration and 1, 5, 10, and 14 days after steroid administration. Regions of interest were set in the bilateral proximal femora. The enhancement ratio, initial slope, and area under the curve were analyzed. These parameters were evaluated after steroid administration in each group and between the two groups, and the ratios of ON in both groups were compared. In the control group, the minimum values of all parameters decreased significantly after steroid administration (P < 0.05), but in the ES group, the parameters did not decrease. In the ES group, all parameter values were significantly increased on the 10th and 14th days (P < 0.05). All parameter values in the ES group were significantly higher than those in the control group on the 14th day (P < 0.05). In the control group, ON was detected in three of five rabbits (in three of ten femora). In the ES group, ON was not detected. These results suggest that increased femoral blood flow elicited by ES may be related to ON prevention after steroid administration.

  2. Gadolinium-enhanced MRI in central nervous system Behcet's disease

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, E. (Dept. of Radiology (Neuroradiology), Hopital de Bicetre, Paris-Sud Univ. (France)); Carlier, R. (Dept. of Radiology (Neuroradiology), Hopital de Bicetre, Paris-Sud Univ. (France)); Idir, A.B.C. (Dept. of Radiology (Neuroradiology), Hopital de Bicetre, Paris-Sud Univ. (France)); Masnou, P.O. (Dept. of Neurology, Hopital de Bicetre, Paris-Sud Univ. (France)); Moulonguet, A. (Dept. of Neurology, Hopital de Bicetre, Paris-Sud Univ. (France)); Adams, D. (Dept. of Neurology, Hopital de Bicetre, Paris-Sud Univ. (France)); Doyon, D. (Dept. of Radiology (Neuroradiology), Hopital de Bicetre, Paris-Sud Univ. (France))

    1993-02-01

    Two cases of central nervous system Behcet's disease, studied by gadolinium-enhanced MRI, are presented. In one patient, whose clinical picture was dominated by a brain stem syndrome, the gadolinium enhancement resolved with clinical improvement, although the hyperintense areas in the mesencephalon on T2-weighted images persisted. In the second, who had a pseudobulbar palsy and a mild right hemiparesis, there were many abnormal areas, but an enhancing focus in the posterior limb of the left internal capsule was probably the lesion responsible for the hemiparesis. (orig.)

  3. Fetal MRI

    International Nuclear Information System (INIS)

    Prayer, D.; Brugger, P.C.

    2004-01-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  4. Interventional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Junta; Dohi, Michiko; Yoshihiro, Akiko; Mogami, Takuji; Kuwada, Tomoko; Nakata, Norio [Jikei Univ., Chiba (Japan). Kashiwa Hospital

    2000-06-01

    Open type MR system and fast sequence is now available and MRI becomes a new modality for interventional Radiology, including biopsy, drainage operation, and monitoring for minimally invasive therapy. Experimental studies of temperature monitoring were performed under hot and cold status. Signal changes of porcine disc and meat under microwave and laser ablation were observed as low signal area by signal intensity method. Using proton chemical shift method, signal change by laser ablation was displaced color imaging and correlated with thermometric temperature measurement. The very T2 relaxation time of ice affords excellent contrast between ice and surrounding gelatin tissue allowing acute depiction of the extent of the iceball under MRI. (author)

  5. Fetal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, D.; Brugger, P.C. [University Hospital of Vienna (Austria). Division of Neuroradiology

    2004-07-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  6. A simple scoring system for breast MRI interpretation: does it compensate for reader experience?

    International Nuclear Information System (INIS)

    Marino, Maria Adele; Clauser, Paola; Woitek, Ramona; Wengert, Georg J.; Kapetas, Panagiotis; Bernathova, Maria; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T.; Preidler, Klaus

    2016-01-01

    To investigate the impact of a scoring system (Tree) on inter-reader agreement and diagnostic performance in breast MRI reading. This IRB-approved, single-centre study included 100 patients with 121 consecutive histopathologically verified lesions (52 malignant, 68 benign). Four breast radiologists with different levels of MRI experience and blinded to histopathology retrospectively evaluated all examinations. Readers independently applied two methods to classify breast lesions: BI-RADS and Tree. BI-RADS provides a reporting lexicon that is empirically translated into likelihoods of malignancy; Tree is a scoring system that results in a diagnostic category. Readings were compared by ROC analysis and kappa statistics. Inter-reader agreement was substantial to almost perfect (kappa: 0.643-0.896) for Tree and moderate (kappa: 0.455-0.657) for BI-RADS. Diagnostic performance using Tree (AUC: 0.889-0.943) was similar to BI-RADS (AUC: 0.872-0.953). Less experienced radiologists achieved AUC: improvements up to 4.7 % using Tree (P-values: 0.042-0.698); an expert's performance did not change (P = 0.526). The least experienced reader improved in specificity using Tree (16 %, P = 0.001). No further sensitivity and specificity differences were found (P > 0.1). The Tree scoring system improves inter-reader agreement and achieves a diagnostic performance similar to that of BI-RADS. Less experienced radiologists, in particular, benefit from Tree. (orig.)

  7. Limbic system, the main focus of dementia syndrome; A study with MRI and PET

    Energy Technology Data Exchange (ETDEWEB)

    Matsuzawa, Taiju [Morinosato Hospital, Atsugi, Kanagawa (Japan)

    1990-12-01

    Alzheimer disease and multi-infarct dementia are two entirely different diseases producing almost the same abnormalities as dementia syndrome. The statistical studies with MRI to locate the focus of dementia syndrome in the neocortex was an absolute failure. With MRI there is drastic atrophy and destruction of the amygdala and hippocampus suggesting the limbic system as the focus of dementia syndrome. Destruction of the limbic system in particular amygdala and hippocampus produced the functional obstruction brought about by the marked reduction in the glucose utilization with PET in the bilateral temporal, parietal and occipital association cortices. Although this type constitutes only about 1/5 of all dementia patients. It is considered the fundamental type of dementia syndrome. Aside from this, there is a type wherein simultaneous and symmetrical reductions in glucose utilization of the frontal association cortex and the motor association cortex in the anterior part of the neocortex. This is referred to as type II. It constitutes about 4/5 of all dementia patients which is far more than type I. Based on these results, it is thought that limbic system is the main focus of dementia syndrome. (author).

  8. MRI of the fingers in patients with systemic scleroderma. Early results of contrast-enhanced examinations on a dedicated MRI system

    International Nuclear Information System (INIS)

    Bonel, H.; Seemann, M.; Reiser, M.; Messer, G.; Walchner, M.; Roecken, M.

    1997-01-01

    Purpose. To estimate disease activity in patients with systemic sclerosis using contrast-enhanced MRI of the skin. Material and Methods. In a pre-study, sequences of a low-field (0.2 T) scanner (Artoscan, Esaote, Genova, Italy) were optimized for detection of intravenous contrast (0.1 mmol/l Gd-DTPA) in six patients with the autoimmune disease systemic scleroderma. Based on the results of the pre-study, 17 patients with scleroderma (7 sclerotic/10 active inflammatory disease) were scanned using gradient-spoiled 3D GRE sequences (FA 90 , TR 100 ms, TE 18 ms), which had been established as most sensitive for intravenous contrast. Contrast enhancement of the skin was determined quantitatively by contrast-to-noise ratios (CNR), comparing post- to pre-contrast and dynamic scans (for 6 min, 1 acquisition/min). Patients in the chronic state with sclerodactylia and active inflammation of the hands were considered separately and compared to a control group (n=10) matched according to age. Results. CNR increase after intravenous contrast was significantly higher in patients with active disease (86±16% increase) than sclerosing disease (29±3%, p [de

  9. SU-E-T-20: Removal of Electron Contamination in Longitudinal Field MRI-Linac Systems: A Monte Carlo Study.

    Science.gov (United States)

    Oborn, B M; Metcalfe, P; Butson, M; Crozier, S; Keall, P

    2012-06-01

    The prototype inline MRI-linac system has some advantages over perpendicular models including avoiding the electron return effect. One of the disadvantages of the inline approach is the increased skin dose, estimated to be 400-1000% of the dmax dose. The purpose of this work was to design a feasible method to reduce this skin dose to acceptable levels. Magnetic modeling of proposed MRI-linac designs have been simulated with the inclusion of an optimized permanent magnet system to purge/deflect the electron contamination. The region of air above the phantom was also replaced with a helium bag (region of helium gas) and a beam scrapper below the deflector was added to collect deflected off-axis contamination. Monte Carlo simulations were then performed including the accurate 3D magnetic field maps. Surface dosimetry was recorded to verify the changes to the skin doses. Magnetic modelling showed that an optimized NdFeB permanent magnet system located outside the MRI coils (below the MLC's) can provide a strong enough region to purge/deflect a significant portion of the electron contamination from the x-ray beam. The impact on the MRI uniformity is around 100 ppm and hence is correctable via active/passive shimming of the MRI. The helium region also significantly limits the production of contamination traveling towards the phantom surface. Entry doses near CAX are predicted to be similar to the 0 T case. Magnetic and Monte Carlo modeling were performed to estimate the effect that a permanent magnet purging system, beam scrapper, and helium bag would have on lowering the skin doses in an inline MRI-Linac system. MRI non-uniformities introduced by the deflector could be corrected, contamination is mostly purged or blocked, and the helium bag minimizes air-generated contamination. As a result skin doses are comparable to having zero magnetic field. © 2012 American Association of Physicists in Medicine.

  10. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    International Nuclear Information System (INIS)

    Gao, Y; Yang, Y; Rangwala, N; Cao, M; Low, D; Hu, P

    2016-01-01

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometric reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10"−"3mm"2/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with excellent

  11. TU-AB-BRA-07: Distortion-Free 3D Diffusion MRI On An MRI-Guided Radiotherapy System for Longitudinal Tumor Response Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Y; Yang, Y; Rangwala, N; Cao, M; Low, D; Hu, P [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To develop a reliable, 3D distortion-free diffusion MRI technique for longitudinal tumor response assessment and MRI-guided adaptive radiotherapy(RT). Methods: A diffusion prepared 3D turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) sequence in a commercially available diffusion phantom, and one head-and-neck and one brain cancer patient on an MRI-guided RT system (ViewRay). In phantom study, the geometric fidelity was quantified as the ratio between the left-right (RL) and anterior-posterior (AP) dimension. Ten slices were measured on DP-TSE, DW-ssEPI and standard TSE images where the later was used as the geometric reference. ADC accuracy was verified at both 0°C (reference ADC available) and room temperature with a range of diffusivity between 0.35 and 2.0*10{sup −3}mm{sup 2}/s. The ADC reproducibility was assessed based on 8 room-temperature measurements on 6 different days. In the pilot single-slice in-vivo study, CT images were used as the geometric reference, and ADC maps from both diffusion sequences were compared. Results: Distortion and susceptive-related artifact were severe in DW-ssEPI, with significantly lower RL/AP ratio (0.9579±0.0163) than DP-TSE (0.9990±0.0031) and TSE (0.9995±0.0031). ADCs from the two diffusion sequences both matched well with the vendor-provided values at 0°C; however DW-ssEPI fails to provide accurate ADC for high diffusivity vials at room temperature due to high noise level (10 times higher than DP-TSE). The DP-TSE sequence had excellent ADC reproducibility with <4% ADC variation among 8 separate measurements. In patient study, DP-TSE exhibited substantially improved geometric reliability. ROI analysis in ADC maps generated from DP-TSE and DW-ssEPI showed <5% difference where high b-value images were excluded from the latter approach due to excessive noise level. Conclusion: A diffusion MRI sequence with

  12. Fetal lung volume measurement by MRI with high-speed imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Osada, Hisao; Kaku, Kenshi [Chiba Univ. (Japan). Hospital

    2002-08-01

    Although ultrasonography is widely used for fetal morphologic observation, magnetic resonance imaging (MRI) has gained popularity as a new prenatal diagnostic method with recent introduction of high-speed imaging systems. Infants with lung hypoplasia affecting respiratory function require intensive management starting immediately after birth. Therefore, accurate prenatal differential diagnosis and severity evaluation are extremely important for these fetuses. The aim of this study is to measure fetal lung volume using a computer-based, three-dimensional MRI imaging system and to evaluate the possibility of clinical applications of this procedure. A total of 96 fetuses were evaluated, all were morphologically abnormal, and MRI was done for advanced assessment from 24 to 39 weeks gestation. Three-directional views of fetal chest were imaged by Signa Horizon, 1.5 Tesla, version 5.6 (General Electronics) with the following conditions; coil: TORSO coil, sequence: SSFSE (single shot fast spin echo), slice thickness: 5 mm, and imaging speed: 2 seconds/slice. To calculate the lung volume and create three-dimensional image, the lung area in each slice was traced out, then multiplied using computer image processing. Simultaneously, the volumes of all slices were summed to give the volume of each lung. Linear regression analysis and analysis of covariance (ANCOVA) were used for statistical analyses. In all cases, clear images were obtained, and were adequate for three-dimensional evaluation of the fetal lung. Thirty-five fetuses had poor outcomes, such as intrauterine fetal death, neonatal death, and intensive respiratory care. Regression lines of lung volume versus gestational week were calculated for these fetuses with poor outcome and 61 other fetuses with good outcome. ANCOVA, with gestational week as a covariant, revealed a significant intergroup difference in the lung volume (p<0.001). Similarly, regression lines of lung volume versus fetal body weight estimated by

  13. Correlation between anatomic foot and ankle movement measured with MRI and with a motion analysis system.

    Science.gov (United States)

    Marquez-Barrientos, C; Liu, X C; Lyon, R; Tassone, C; Thometz, J; Tarima, S

    2012-07-01

    Several studies have attempted to measure how well external markers track internal bone movement using pins drilled into the foot, but this is too invasive for the pediatric population. This study investigated how well a six segment foot model (6SFM) using external markers was able to measure bone movement in the foot compared to MRI measurements. The foot was moved into different positions using a plastic foot jig and measurements were taken with both systems. The aims were to: (1) Look at the correlation between movement tracked with an Electronic Motion Tracking System (EMTS) and by measurements derived from MRI images, specifically the principal intercept angles (PIAs) which are the angles of intersection between principal axes of inertia of bone volumes. (2) To see how well external motion measured by the 6SFM could predict PIAs. Four bone pairs had their movement tracked: Tibia-Calcaneus, Calcaneus-Cuboid, Navicular-1st Metatarsal, and 1st Metatarsal-Hallux. The results showed moderate correlation between measured PIAs and those predicted at the Tibia-Calcaneus, Navicular-1st Metatarsal, and 1st Metatarsal-Hallux joints. Moderate to high correlation was found between the PIA and movement in a single anatomic plane for all four joints at several positions. The 6SFM using the EMTS allows reliable tracking of 3D rotations in the pediatric foot, except at the Calcaneus-Cuboid joint. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Concurrent TMS-fMRI Reveals Interactions between Dorsal and Ventral Attentional Systems

    DEFF Research Database (Denmark)

    Leitao, Joana; Thielscher, Axel; Tuennerhoff, Johannes

    2015-01-01

    interactively in this process. This fMRI study used concurrent transcranial magnetic stimulation (TMS) as a causal perturbation approach to investigate the interactions between dorsal and ventral attentional systems and sensory processing areas. In a sustained spatial attention paradigm, human participants......Adaptive behavior relies on combining bottom-up sensory inputs with top-down control signals to guide responses in line with current goals and task demands. Over the past decade, accumulating evidence has suggested that the dorsal and ventral frontoparietal attentional systems are recruited......-TMS relative to Sham-TMS increased activation in the parietal cortex regardless of sensory stimulation, confirming the neural effectiveness of TMS stimulation. Visual targets increased activations in the anterior insula, a component of the ventral attentional system responsible for salience detection...

  15. Using systems thinking in state health policymaking: an educational initiative.

    Science.gov (United States)

    Minyard, Karen J; Ferencik, Rachel; Ann Phillips, Mary; Soderquist, Chris

    2014-06-01

    In response to limited examples of opportunities for state policymakers to learn about and productively discuss the difficult, adaptive challenges of our health system, the Georgia Health Policy Center developed an educational initiative that applies systems thinking to health policymaking. We created the Legislative Health Policy Certificate Program - an in-depth, multi-session series for lawmakers and their staff - concentrating on building systems thinking competencies and health content knowledge by applying a range of systems thinking tools: behavior over time graphs, stock and flow maps, and a system dynamics-based learning lab (a simulatable model of childhood obesity). Legislators were taught to approach policy issues from the big picture, consider changing dynamics, and explore higher-leverage interventions to address Georgia's most intractable health challenges. Our aim was to determine how we could improve the policymaking process by providing a systems thinking-focused educational program for legislators. Over 3 years, the training program resulted in policymakers' who are able to think more broadly about difficult health issues. The program has yielded valuable insights into the design and delivery of policymaker education that could be applied to various disciplines outside the legislative process.

  16. Hyperintense signal alteration in the suprapatellar fat pad on MRI is associated with degeneration of the patellofemoral joint over 48 months. Data from the Osteoarthritis Initiative

    International Nuclear Information System (INIS)

    Schwaiger, Benedikt J.; Gersing, Alexandra S.; Mbapte Wamba, John; Facchetti, Luca; Link, Thomas M.; Nevitt, Michael C.; McCulloch, Charles E.

    2018-01-01

    To analyze associations of suprapatellar fat pad (SPFP) hyperintense signal alterations and mass effect with progression of patellofemoral osteoarthritis (OA) and clinical symptoms over 48 months. Subjects from the Osteoarthritis Initiative (n = 426; 51.8 ± 3.8 years; 49.8% women) without radiographic tibiofemoral OA underwent 3T-MRI of their right knees and clinical evaluation using the Knee Injury and Osteoarthritis Outcome Score at baseline and at 48 months. Elevated SPFP signal was assessed on intermediate-weighted, fat-saturated turbo spin-echo (TSE) images. Mass effect was defined as a convex posterior contour. Patellofemoral cartilage, bone marrow lesions (BML), and subchondral cysts were assessed using the Whole-Organ Magnetic Resonance Imaging Score (WORMS). Associations of SPFP imaging findings with MRI and clinical progression were assessed using general linear models and logistic regressions. Baseline SPFP signal alterations were found in 51% of the subjects (n = 217), of whom 11% (n = 23) additionally had a mass effect. Progression of cartilage lesions was significantly higher in subjects with signal alteration versus without (adjusted mean increases, 95% CI; patella: 0.29, -0.07 to 0.64 vs -0.04, -0.40 to 0.31; p < 0.001; trochlea: 0.47, 0.16 to 0.77 vs 0.31, 0.01 to 0.61; p = 0.007). BML progression was also more likely in subjects with signal alteration (OR 1.75, 95% CI 1.09 to 2.82; p = 0.021). Mass effect was not associated with joint degeneration and SPFP findings were not associated with clinical worsening (p > 0.18 for all). Patellofemoral joint degeneration over 48 months was significantly increased in subjects with SPFP signal alteration, suggesting an association between SPFP abnormalities and the progression of patellofemoral OA. (orig.)

  17. Hyperintense signal alteration in the suprapatellar fat pad on MRI is associated with degeneration of the patellofemoral joint over 48 months. Data from the Osteoarthritis Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Schwaiger, Benedikt J.; Gersing, Alexandra S. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Technical University of Munich, Department of Radiology, Klinikum Rechts der Isar, Munich (Germany); Mbapte Wamba, John; Facchetti, Luca; Link, Thomas M. [University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Nevitt, Michael C.; McCulloch, Charles E. [University of California, Department of Epidemiology and Biostatistics, San Francisco, CA (United States)

    2018-03-15

    To analyze associations of suprapatellar fat pad (SPFP) hyperintense signal alterations and mass effect with progression of patellofemoral osteoarthritis (OA) and clinical symptoms over 48 months. Subjects from the Osteoarthritis Initiative (n = 426; 51.8 ± 3.8 years; 49.8% women) without radiographic tibiofemoral OA underwent 3T-MRI of their right knees and clinical evaluation using the Knee Injury and Osteoarthritis Outcome Score at baseline and at 48 months. Elevated SPFP signal was assessed on intermediate-weighted, fat-saturated turbo spin-echo (TSE) images. Mass effect was defined as a convex posterior contour. Patellofemoral cartilage, bone marrow lesions (BML), and subchondral cysts were assessed using the Whole-Organ Magnetic Resonance Imaging Score (WORMS). Associations of SPFP imaging findings with MRI and clinical progression were assessed using general linear models and logistic regressions. Baseline SPFP signal alterations were found in 51% of the subjects (n = 217), of whom 11% (n = 23) additionally had a mass effect. Progression of cartilage lesions was significantly higher in subjects with signal alteration versus without (adjusted mean increases, 95% CI; patella: 0.29, -0.07 to 0.64 vs -0.04, -0.40 to 0.31; p < 0.001; trochlea: 0.47, 0.16 to 0.77 vs 0.31, 0.01 to 0.61; p = 0.007). BML progression was also more likely in subjects with signal alteration (OR 1.75, 95% CI 1.09 to 2.82; p = 0.021). Mass effect was not associated with joint degeneration and SPFP findings were not associated with clinical worsening (p > 0.18 for all). Patellofemoral joint degeneration over 48 months was significantly increased in subjects with SPFP signal alteration, suggesting an association between SPFP abnormalities and the progression of patellofemoral OA. (orig.)

  18. The relationship between three-dimensional knee MRI bone shape and total knee replacement—a case control study: data from the Osteoarthritis Initiative

    Science.gov (United States)

    Barr, Andrew J.; Dube, Bright; Hensor, Elizabeth M. A.; Kingsbury, Sarah R.; Peat, George; Bowes, Mike A.; Sharples, Linda D.

    2016-01-01

    Objective. There is growing understanding of the importance of bone in OA. Our aim was to determine the relationship between 3D MRI bone shape and total knee replacement (TKR). Methods. A nested case-control study within the Osteoarthritis Initiative cohort identified case knees with confirmed TKR for OA and controls that were matched using propensity scores. Active appearance modelling quantification of the bone shape of all knee bones identified vectors between knees having or not having OA. Vectors were scaled such that −1 and +1 represented the mean non-OA and mean OA shapes. Results. Compared to controls (n = 310), TKR cases (n = 310) had a more positive mean baseline 3D bone shape vector, indicating more advanced structural OA, for the femur [mean 0.98 vs −0.11; difference (95% CI) 1.10 (0.88, 1.31)], tibia [mean 0.86 vs −0.07; difference (95% CI) 0.94 (0.72, 1.16)] and patella [mean 0.95 vs 0.03; difference (95% CI) 0.92 (0.65, 1.20)]. Odds ratios (95% CI) for TKR per normalized unit of 3D bone shape vector for the femur, tibia and patella were: 1.85 (1.59, 2.16), 1.64 (1.42, 1.89) and 1.36 (1.22, 1.50), respectively, all P < 0.001. After including Kellgren–Lawrence grade in a multivariable analysis, only the femur 3D shape vector remained significantly associated with TKR [odds ratio 1.24 (1.02, 1.51)]. Conclusion. 3D bone shape was associated with the endpoint of this study, TKR, with femoral shape being most associated. This study contributes to the validation of quantitative MRI bone biomarkers for OA structure-modification trials. PMID:27185958

  19. Obesity increases the prevalence and severity of focal knee abnormalities diagnosed using 3T MRI in middle-aged subjects - data from the osteoarthritis initiative

    International Nuclear Information System (INIS)

    Laberge, Marc A.; Baum, Thomas; Virayavanich, Warapat; Nardo, Lorenzo; Link, Thomas M.; Nevitt, M.C.; Lynch, J.; McCulloch, C.E.

    2012-01-01

    To study the effect of BMI on the prevalence, severity, and 36-month progression of early degenerative changes in the knee by using 3T MRI in middle-aged subjects without radiographic osteoarthritis (OA). We examined baseline and 36-month follow-up MR studies from 137 middle-aged individuals (45-55 years old) with risk factors for knee OA but no radiographic OA from the Osteoarthritis Initiative. Subjects were grouped into three categories: normal BMI (BMI 2 , n = 38), overweight (BMI 25-29.9 kg/m 2 , n = 37), and obese (BMI ≥ 30 kg/m 2 , n = 62). Using 3T MRI, cartilage, meniscus, and bone marrow abnormalities were graded using the OA Whole-organ MR Imaging Score (WORMS). The statistical analysis was corrected as necessary for differences in age, sex, and OA risk factors other than BMI. The overall prevalence of lesions was 64% for meniscus and 79% for cartilage (including low grade lesions). At baseline, the prevalence and severity of knee lesions was positively associated with BMI, with a nearly fourfold increase in meniscal tears and more than twofold increase in high-grade cartilage defects in obese individuals relative to normal-weight subjects. Over the 36-month follow-up period, the number of new or worsening cartilage lesions of any grade was significantly higher in obese subjects (p = 0.039), while there was no significant difference in meniscal lesion progression. Obesity was associated with both higher prevalence and severity of early degenerative changes in the knee in middle-aged individuals without radiographic OA and with significantly increased cartilage lesion progression (of any grade) over 36 months. (orig.)

  20. Obesity increases the prevalence and severity of focal knee abnormalities diagnosed using 3T MRI in middle-aged subjects - data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Laberge, Marc A.; Baum, Thomas; Virayavanich, Warapat; Nardo, Lorenzo; Link, Thomas M. [University of California San Francisco, Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Nevitt, M.C.; Lynch, J.; McCulloch, C.E. [University of California San Francisco, Department of Epidemiology and Biostatistics, San Francisco, CA (United States)

    2012-06-15

    To study the effect of BMI on the prevalence, severity, and 36-month progression of early degenerative changes in the knee by using 3T MRI in middle-aged subjects without radiographic osteoarthritis (OA). We examined baseline and 36-month follow-up MR studies from 137 middle-aged individuals (45-55 years old) with risk factors for knee OA but no radiographic OA from the Osteoarthritis Initiative. Subjects were grouped into three categories: normal BMI (BMI < 25 kg/m{sup 2}, n = 38), overweight (BMI 25-29.9 kg/m{sup 2}, n = 37), and obese (BMI {>=} 30 kg/m{sup 2}, n = 62). Using 3T MRI, cartilage, meniscus, and bone marrow abnormalities were graded using the OA Whole-organ MR Imaging Score (WORMS). The statistical analysis was corrected as necessary for differences in age, sex, and OA risk factors other than BMI. The overall prevalence of lesions was 64% for meniscus and 79% for cartilage (including low grade lesions). At baseline, the prevalence and severity of knee lesions was positively associated with BMI, with a nearly fourfold increase in meniscal tears and more than twofold increase in high-grade cartilage defects in obese individuals relative to normal-weight subjects. Over the 36-month follow-up period, the number of new or worsening cartilage lesions of any grade was significantly higher in obese subjects (p = 0.039), while there was no significant difference in meniscal lesion progression. Obesity was associated with both higher prevalence and severity of early degenerative changes in the knee in middle-aged individuals without radiographic OA and with significantly increased cartilage lesion progression (of any grade) over 36 months. (orig.)

  1. Implication of the dominant design in electronic initiation systems in the South African mining industry

    CSIR Research Space (South Africa)

    Smit, FC

    1998-11-01

    Full Text Available This article analyzes an emerging technological innovation, namely, electronic initiation systems for mining explosives in South Africa. The concept of electronic initiation is presenting itself as a challenge to traditional initiation systems...

  2. Simultaneous fMRI-PET of the opioidergic pain system in human brain

    DEFF Research Database (Denmark)

    Wey, Hsiao-Ying; Catana, Ciprian; Hooker, Jacob M

    2014-01-01

    distinct components of the blood oxygenation level dependent (BOLD) fMRI signal has not yet been shown. We obtained sixteen fMRI-PET data sets from eight healthy volunteers. Each subject participated in randomized order in a pain scan and a control (nonpainful pressure) scan on the same day. Dynamic PET......MRI and PET provide complementary information for studying brain function. While the potential use of simultaneous MRI/PET for clinical diagnostic and disease staging has been demonstrated recently; the biological relevance of concurrent functional MRI-PET brain imaging to dissect neurochemically...... data were acquired with an opioid radioligand, [(11)C]diprenorphine, to detect endogenous opioid releases in response to pain. BOLD fMRI data were collected at the same time to capture hemodynamic responses. In this simultaneous human fMRI-PET imaging study, we show co-localized responses in thalamus...

  3. Afghanistan Digital Library Initiative: Revitalizing an Integrated Library System

    Directory of Open Access Journals (Sweden)

    Yan HAN

    2007-12-01

    Full Text Available This paper describes an Afghanistan digital library initiative of building an integrated library system (ILS for Afghanistan universities and colleges based on open-source software. As one of the goals of the Afghan eQuality Digital Libraries Alliance, the authors applied systems analysis approach, evaluated different open-source ILSs, and customized the selected software to accommodate users’ needs. Improvements include Arabic and Persian language support, user interface changes, call number label printing, and ISBN-13 support. To our knowledge, this ILS is the first at a large academic library running on open-source software.

  4. A computer-aided detection system for rheumatoid arthritis MRI data interpretation and quantification of synovial activity

    DEFF Research Database (Denmark)

    Kubassove, Olga; Boesen, Mikael; Cimmino, Marco A

    2009-01-01

    and interpretation slow down development in this area. Existing scoring systems of especially synovitis are too rigid and insensitive to measure early treatment response and quantify inflammation. This study tested a novel automated, computer system for analysis of dynamic MRI data acquired from patients with RA...

  5. Proof-of-principle study of a small animal PET/field-cycled MRI combined system using conventional PMT technology

    International Nuclear Information System (INIS)

    Peng Hao; Handler, William B.; Scholl, Timothy J.; Simpson, P.J.; Chronik, Blaine A.

    2010-01-01

    There are currently several approaches to the development of combined PET/MRI systems, all of which need to address adverse interactions between the two systems. Of particular relevance to the majority of proposed PET/MRI systems is the effect that static and dynamic magnetic fields have on the performance of PET detection systems based on photomultiplier tubes (PMTs). In the work reported in this paper, performance of two conventional PMTs has been systematically investigated and characterized as a function of magnetic field exposure conditions. Detector gain, energy resolution, time resolution, and efficiency were measured for static field exposures between 0 and 6.3 mT. Additionally, the short-term recovery and long-term stability of gain and energy resolution were measured in the presence of repeatedly applied dynamic magnetic fields changing at 4 T/s. It was found that the detectors recovered normal operation within several milliseconds following the end of large pulsed magnetic fields. In addition, the repeated applications of large pulsed magnetic fields did not significantly affect detector stability. Based on these results, we implemented a proof-of-principle PET/field-cycled MRI (FCMRI) system for small animal imaging using commercial PMT-based PET detectors. The first PET images acquired within the PET/FCMRI system are presented. The image quality, in terms of spatial resolution, was compared between standalone PET and the PET/FCMRI system. Finally, the relevance of these results to various aspects of PET/MRI system design is discussed.

  6. The Initial Development of a Computerized Operator Support System

    Energy Technology Data Exchange (ETDEWEB)

    Roger Lew; Ronald L Boring; Thomas A Ulrich; Ken Thomas

    2014-08-01

    A computerized operator support system (COSS) is a collection of resilient software technologies to assist operators in monitoring overall nuclear power plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. The COSS provides rapid assessments, computations, and recommendations to reduce workload and augment operator judgment and decision-making during fast- moving, complex events. A prototype COSS for a chemical volume control system at a nuclear power plant has been developed in order to demonstrate the concept and provide a test bed for further research. The development process identified four underlying elements necessary for the prototype, which consist of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. An operational prototype resides at the Idaho National Laboratory (INL) using the U.S. Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Human Systems Simulation Laboratory (HSSL). Several human-machine interface (HMI) considerations are identified and incorporated in the prototype during this initial round of development.

  7. Research on Initiation Sensitivity of Solid Explosive and Planer Initiation System

    OpenAIRE

    N Matsuo; M Otuka; H Hamasima; K Hokamoto; S Itoh

    2016-01-01

    Firstly, recently, there are a lot of techniques being demanded for complex process, various explosive initiation method and highly accurate control of detonation are needed. In this research, the metal foil explosion using high current is focused attention on the method to obtain linear or planate initiation easily, and the main evaluation of metal foil explosion to initiate explosive was conducted. The explosion power was evaluated by observing optically the underwater shock wave generated ...

  8. Quantitative MRI study of progressive cerebral atrophy in multiple system atrophy

    International Nuclear Information System (INIS)

    Konagaya, Masaaki; Matsuoka, Yukihiko; Konagaya, Yoko

    2002-01-01

    We investigated cerebral atrophy in multiple system atrophy (MSA) by quantitative analysis of MRI. The subjects were 28 patients with MSA (14 striato-nigral degeneration; SND, 14 olivo-ponto-cerebellar atrophy; OPCA. 106 MRI examinations were performed totally) and 85 normal persons for control. The ratios of the ventral pons to the infratentorial space in the sagittal section, the putamen, cerebrum, frontal lobe and parietal and occipital lobes to the intracranial space in the horizontal section, and the temporal lobe to the intracranial space in the coronal section were measured. In the early stage of the disease, OPCA showed significant atrophy of the ventral pons compared with SND, and conversely, SND demonstrated significantly smaller putamen than that in OPCA. According to the progression of the disease, the atrophy of these neural tissues progressed, which resulted in so significant differences between SND and OPCA. The cerebral atrophy was observed in 17 MSA patients. The atrophy of the frontal lobe was much frequent and prominent to that in the temporal lobe and parietal and occipital lobes. SND showed higher incidence of the cerebral atrophy than OPCA in the early stage of the disease. In long period follow-up cases, one case showed cerebral atrophy in earlier stage, and another case in late stage. We indicated the involvement of the cerebral hemispheres in MSA, especially the frontal lobe. (author)

  9. Quantitative MRI study of progressive cerebral atrophy in multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Konagaya, Masaaki; Matsuoka, Yukihiko [Suzuka National Hospital, Suzuka, Mie (Japan); Konagaya, Yoko [JR Tokai General Hospital, Nagoya (Japan)

    2002-02-01

    We investigated cerebral atrophy in multiple system atrophy (MSA) by quantitative analysis of MRI. The subjects were 28 patients with MSA (14 striato-nigral degeneration; SND, 14 olivo-ponto-cerebellar atrophy; OPCA. 106 MRI examinations were performed totally) and 85 normal persons for control. The ratios of the ventral pons to the infratentorial space in the sagittal section, the putamen, cerebrum, frontal lobe and parietal and occipital lobes to the intracranial space in the horizontal section, and the temporal lobe to the intracranial space in the coronal section were measured. In the early stage of the disease, OPCA showed significant atrophy of the ventral pons compared with SND, and conversely, SND demonstrated significantly smaller putamen than that in OPCA. According to the progression of the disease, the atrophy of these neural tissues progressed, which resulted in so significant differences between SND and OPCA. The cerebral atrophy was observed in 17 MSA patients. The atrophy of the frontal lobe was much frequent and prominent to that in the temporal lobe and parietal and occipital lobes. SND showed higher incidence of the cerebral atrophy than OPCA in the early stage of the disease. In long period follow-up cases, one case showed cerebral atrophy in earlier stage, and another case in late stage. We indicated the involvement of the cerebral hemispheres in MSA, especially the frontal lobe. (author)

  10. The development of an MRI lesion quantifying system for multiple sclerosis patients undergoing treatment

    Science.gov (United States)

    Moin, Paymann; Ma, Kevin; Amezcua, Lilyana; Gertych, Arkadiusz; Liu, Brent

    2009-02-01

    Multiple sclerosis (MS) is a demyelinating disease of the central nervous system that affects approximately 2.5 million people worldwide. Magnetic resonance imaging (MRI) is an established tool for the assessment of disease activity, progression and response to treatment. The progression of the disease is variable and requires routine follow-up imaging studies. Currently, MRI quantification of multiple sclerosis requires a manual approach to lesion measurement and yields an estimate of lesion volume and interval change. In the setting of several prior studies and a long treatment history, trends related to treatment change quickly become difficult to extrapolate. Our efforts seek to develop an imaging informatics based MS lesion computer aided detection (CAD) package to quantify and track MS lesions including lesion load, volume, and location. Together, with select clinical parameters, this data will be incorporated into an MS specific e- Folder to provide decision support to evaluate and assess treatment options for MS in a manner tailored specifically to an individual based on trends in MS presentation and progression.

  11. An Automated and Intelligent Medical Decision Support System for Brain MRI Scans Classification.

    Directory of Open Access Journals (Sweden)

    Muhammad Faisal Siddiqui

    Full Text Available A wide interest has been observed in the medical health care applications that interpret neuroimaging scans by machine learning systems. This research proposes an intelligent, automatic, accurate, and robust classification technique to classify the human brain magnetic resonance image (MRI as normal or abnormal, to cater down the human error during identifying the diseases in brain MRIs. In this study, fast discrete wavelet transform (DWT, principal component analysis (PCA, and least squares support vector machine (LS-SVM are used as basic components. Firstly, fast DWT is employed to extract the salient features of brain MRI, followed by PCA, which reduces the dimensions of the features. These reduced feature vectors also shrink the memory storage consumption by 99.5%. At last, an advanced classification technique based on LS-SVM is applied to brain MR image classification using reduced features. For improving the efficiency, LS-SVM is used with non-linear radial basis function (RBF kernel. The proposed algorithm intelligently determines the optimized values of the hyper-parameters of the RBF kernel and also applied k-fold stratified cross validation to enhance the generalization of the system. The method was tested by 340 patients' benchmark datasets of T1-weighted and T2-weighted scans. From the analysis of experimental results and performance comparisons, it is observed that the proposed medical decision support system outperformed all other modern classifiers and achieves 100% accuracy rate (specificity/sensitivity 100%/100%. Furthermore, in terms of computation time, the proposed technique is significantly faster than the recent well-known methods, and it improves the efficiency by 71%, 3%, and 4% on feature extraction stage, feature reduction stage, and classification stage, respectively. These results indicate that the proposed well-trained machine learning system has the potential to make accurate predictions about brain abnormalities

  12. A computer-aided detection system for rheumatoid arthritis MRI data interpretation and quantification of synovial activity

    DEFF Research Database (Denmark)

    Kubassove, Olga; Boesen, Mikael; Cimmino, Marco A

    2009-01-01

    RATIONAL AND OBJECTIVE: Disease assessment and follow-up of rheumatoid arthritis (RA) patients require objective evaluation and quantification. Magnetic resonance imaging (MRI) has a large potential to supplement such information for the clinician, however, time spent on data reading...... and interpretation slow down development in this area. Existing scoring systems of especially synovitis are too rigid and insensitive to measure early treatment response and quantify inflammation. This study tested a novel automated, computer system for analysis of dynamic MRI data acquired from patients with RA......, Dynamika-RA, which incorporates efficient data processing and analysis techniques....

  13. A Java-based fMRI processing pipeline evaluation system for assessment of univariate general linear model and multivariate canonical variate analysis-based pipelines.

    Science.gov (United States)

    Zhang, Jing; Liang, Lichen; Anderson, Jon R; Gatewood, Lael; Rottenberg, David A; Strother, Stephen C

    2008-01-01

    As functional magnetic resonance imaging (fMRI) becomes widely used, the demands for evaluation of fMRI processing pipelines and validation of fMRI analysis results is increasing rapidly. The current NPAIRS package, an IDL-based fMRI processing pipeline evaluation framework, lacks system interoperability and the ability to evaluate general linear model (GLM)-based pipelines using prediction metrics. Thus, it can not fully evaluate fMRI analytical software modules such as FSL.FEAT and NPAIRS.GLM. In order to overcome these limitations, a Java-based fMRI processing pipeline evaluation system was developed. It integrated YALE (a machine learning environment) into Fiswidgets (a fMRI software environment) to obtain system interoperability and applied an algorithm to measure GLM prediction accuracy. The results demonstrated that the system can evaluate fMRI processing pipelines with univariate GLM and multivariate canonical variates analysis (CVA)-based models on real fMRI data based on prediction accuracy (classification accuracy) and statistical parametric image (SPI) reproducibility. In addition, a preliminary study was performed where four fMRI processing pipelines with GLM and CVA modules such as FSL.FEAT and NPAIRS.CVA were evaluated with the system. The results indicated that (1) the system can compare different fMRI processing pipelines with heterogeneous models (NPAIRS.GLM, NPAIRS.CVA and FSL.FEAT) and rank their performance by automatic performance scoring, and (2) the rank of pipeline performance is highly dependent on the preprocessing operations. These results suggest that the system will be of value for the comparison, validation, standardization and optimization of functional neuroimaging software packages and fMRI processing pipelines.

  14. Contrast-Enhanced Spectral Mammography is Comparable to MRI in the Assessment of Residual Breast Cancer Following Neoadjuvant Systemic Therapy.

    Science.gov (United States)

    Patel, Bhavika K; Hilal, Talal; Covington, Matthew; Zhang, Nan; Kosiorek, Heidi E; Lobbes, Marc; Northfelt, Donald W; Pockaj, Barbara A

    2018-05-01

    To evaluate the performance of contrast-enhanced spectral mammography (CESM) compared to MRI in the assessment of tumor response in breast cancer patients undergoing neoadjuvant systemic therapy (NST). The institutional review board approved this study. From September 2014 to June 2017, we identified patients with pathologically confirmed invasive breast cancer who underwent NST. All patients had both CESM and MRI performed pre- and post-NST with pathological assessment after surgical management. Size of residual malignancy on post-NST CESM and MRI was compared with surgical pathology. Lin concordance and Pearson correlation coefficient were used to assess agreement. Bland-Altman plots were used to visualize the differences between tumor size on imaging and pathology. Sixty-five patients were identified. Mean age was 52.7 (range 30-76) years. Type of NST included chemotherapy in 53 (82%) and endocrine therapy in 12 (18%). Mean tumor size after NST was 14.6 (range 0-105) mm for CESM and 14.2 mm (range 0-75 mm) for MRI compared with 19.6 (range 0-100) mm on final surgical pathology. Equivalence tests demonstrated that mean tumor size measured by CESM (p = 0.009) or by MRI (p = 0.01) was equivalent to the mean tumor size measured by pathology within - 1 and 1-cm range. Comparing CESM versus MRI for assessment of complete response, the sensitivity was 95% versus 95%, specificity 66.7% versus 68.9%, positive predictive value 55.9% versus 57.6%, and negative predictive value 96.7% versus 96.9% respectively. CESM was comparable to MRI in assessing residual malignancy after completion of NST.

  15. Efficiency of unenhanced MRI in the diagnosis of acute appendicitis: Comparison with Alvarado scoring system and histopathological results

    International Nuclear Information System (INIS)

    Inci, Ercan; Hocaoglu, Elif; Aydin, Sibel; Palabiyik, Figen; Cimilli, Tan; Turhan, Ahmet Nuray; Ayguen, Ersan

    2011-01-01

    Purpose: The purpose of this study was to assess the diagnostic value of unenhanced magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis and compare with Alvarado scores and histopathological results. Materials and methods: The study included 85 consecutive patients (mean age, 26.5 ± 11.3 years) who were clinically suspected of having acute appendicitis. Each patients Alvarado scores were recorded and unenhanced MRI was performed, consisting of T1-weighted, T2-weighted and fat-suppressed T2-weighted fast spin-echo sequences. The MR images were prospectively reviewed in consensus for the presence of acute appendicitis by two radiologists who were blinded to the results of the Alvarado scores. The study population were divided into three subgroups based on the MRI findings: Group I: definitely not appendicitis, Group II: probably appendicitis, Group III: definitely appendicitis. All patients were divided into two subgroups according to Alvarado scores as Group A (low: 1-6), and Group B (high: 7-10). MR findings were compared with Alvarado scores and histopathological findings. Results: Sixty-six (77.6%) of the 85 patients with clinically suspected acute appendicitis, had undergone surgery. The diagnosis of appendicitis could be correctly achieved with MRI in 55 (83.3%) of 57 (86.4%) patients with histopathologically proven acute appendicitis. The sensitivity, specificity, positive predictive value and negative predictive value of MRI examination and Alvarado scoring system in the diagnosis of acute appendicitis were 96.49%, 66.67%, 94.83%, 75.0% and 84.21%, 66.67%, 94.12%, 40.0%, respectively. Conclusions: MRI is a valuable technique for detecting acute appendicitis even in the cases with low Alvarado scores. To increase the diagnostic accuracy and preventing unnecessary laparotomies for suspected appendicitis, shorter and cheaper unenhanced basic MRI may be performed.

  16. Efficiency of unenhanced MRI in the diagnosis of acute appendicitis: Comparison with Alvarado scoring system and histopathological results

    Energy Technology Data Exchange (ETDEWEB)

    Inci, Ercan, E-mail: ercan_inci@mynet.com [Department of Radiology, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Incirli-Bakirkoy, Istanbul (Turkey); Hocaoglu, Elif; Aydin, Sibel; Palabiyik, Figen; Cimilli, Tan [Department of Radiology, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Incirli-Bakirkoy, Istanbul (Turkey); Turhan, Ahmet Nuray; Ayguen, Ersan [Department of Surgery, Istanbul Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Istanbul (Turkey)

    2011-11-15

    Purpose: The purpose of this study was to assess the diagnostic value of unenhanced magnetic resonance imaging (MRI) in the diagnosis of acute appendicitis and compare with Alvarado scores and histopathological results. Materials and methods: The study included 85 consecutive patients (mean age, 26.5 {+-} 11.3 years) who were clinically suspected of having acute appendicitis. Each patients Alvarado scores were recorded and unenhanced MRI was performed, consisting of T1-weighted, T2-weighted and fat-suppressed T2-weighted fast spin-echo sequences. The MR images were prospectively reviewed in consensus for the presence of acute appendicitis by two radiologists who were blinded to the results of the Alvarado scores. The study population were divided into three subgroups based on the MRI findings: Group I: definitely not appendicitis, Group II: probably appendicitis, Group III: definitely appendicitis. All patients were divided into two subgroups according to Alvarado scores as Group A (low: 1-6), and Group B (high: 7-10). MR findings were compared with Alvarado scores and histopathological findings. Results: Sixty-six (77.6%) of the 85 patients with clinically suspected acute appendicitis, had undergone surgery. The diagnosis of appendicitis could be correctly achieved with MRI in 55 (83.3%) of 57 (86.4%) patients with histopathologically proven acute appendicitis. The sensitivity, specificity, positive predictive value and negative predictive value of MRI examination and Alvarado scoring system in the diagnosis of acute appendicitis were 96.49%, 66.67%, 94.83%, 75.0% and 84.21%, 66.67%, 94.12%, 40.0%, respectively. Conclusions: MRI is a valuable technique for detecting acute appendicitis even in the cases with low Alvarado scores. To increase the diagnostic accuracy and preventing unnecessary laparotomies for suspected appendicitis, shorter and cheaper unenhanced basic MRI may be performed.

  17. A medical software system for volumetric analysis of cerebral pathologies in magnetic resonance imaging (MRI) data.

    Science.gov (United States)

    Egger, Jan; Kappus, Christoph; Freisleben, Bernd; Nimsky, Christopher

    2012-08-01

    In this contribution, a medical software system for volumetric analysis of different cerebral pathologies in magnetic resonance imaging (MRI) data is presented. The software system is based on a semi-automatic segmentation algorithm and helps to overcome the time-consuming process of volume determination during monitoring of a patient. After imaging, the parameter settings-including a seed point-are set up in the system and an automatic segmentation is performed by a novel graph-based approach. Manually reviewing the result leads to reseeding, adding seed points or an automatic surface mesh generation. The mesh is saved for monitoring the patient and for comparisons with follow-up scans. Based on the mesh, the system performs a voxelization and volume calculation, which leads to diagnosis and therefore further treatment decisions. The overall system has been tested with different cerebral pathologies-glioblastoma multiforme, pituitary adenomas and cerebral aneurysms- and evaluated against manual expert segmentations using the Dice Similarity Coefficient (DSC). Additionally, intra-physician segmentations have been performed to provide a quality measure for the presented system.

  18. Expert system for the CPCS-initiated trip analysis

    International Nuclear Information System (INIS)

    Sohn, Sedo; Im, Inyoung; Kuh, Jungeui

    1991-01-01

    In Yonggwang nuclear units 3 and 4, the core protection calculator system (CPCS) performs various protection logics against many transients and certain accidents. The CPCS is a real-time computer system calculating the departure from nucleate boiling ratio (DNBR), and local power density, and other protection logics. It takes process variables such as neutron flux, hot-leg temperature, cold-leg temperature, control element assembly positions, and reactor coolant pump shaft speed. Since the CPCS protection logics are quite complex, it is difficult for an operator to tell immediately which parameter is the major cause of the reactor trip. Thus, whenever the reactor trip signal is generated, the process input variables and calculated results, including selected intermediate variables, are frozen in the specified computer memory for later analysis. These frozen variables are called the trip buffer. Analysis of the trip buffer requires an expert in the CPCS and related documents containing algorithms and a data base for algorithms. The Trip Buffer Analysis Program (TBAP) is an expert system that pinpoints the causes of the CPCS initiated reactor trip, thus relieving the operator from the burden of analyzing the trip buffer

  19. Initial Experience with the Machine Protection System for LHC

    CERN Document Server

    Schmidt, Ruediger; Dehning, Bernd; Ferro-Luzzi, Massimiliano; Goddard, Brennan; Lamont, Mike; Siemko, Andrzej; Uythoven, Jan; Wenninger, Jorg; Zerlauth, Markus

    2010-01-01

    For nominal beam parameters at 7 TeV/c each proton beam with a stored energy of 362 MJ threatens to damage accelerator equipment in case of uncontrolled beam loss. These parameters will only be reached after some years of operation, however, a small fraction of this energy is already sufficient to damage accelerator equipment or experiments. The correct functioning of the machine protection systems is vital during the different operational phases already for initial operation. When operating the complex magnet system, with and without beam, safe operation relies on the protection and interlock systems for the superconducting circuits. For safe injection and transfer of the beams from SPS to LHC, transfer line parameters are monitored, beam absorbers must be in the correct position and the LHC must be ready to accept beam. At the end of a fill and in case of failures beams must be properly extracted onto the dump blocks, for some types of failure within less than few hundred microseconds. Safe operation requir...

  20. Power system requirements and selection for the space exploration initiative

    International Nuclear Information System (INIS)

    Biringer, K.L.; Bartine, D.E.; Buden, D.; Foreman, J.; Harrison, S.

    1991-01-01

    The Space Exploration Initiative (SEI) seeks to reestablish a US program of manned and unmanned space exploration. The President has called for a program which includes a space station element, a manned habitation of the moon, and a human exploration of Mars. The NASA Synthesis Group has developed four significantly different architectures for the SEI program. One key element of a space exploration effort is the power required to support the missions. The Power Speciality Team of the Synthesis Group was tasked with assessing and evaluating the power requirements and candidate power technologies for such missions. Inputs to the effort came from existing NASA studies as well as other governments agency inputs such as those from DOD and DOE. In addition, there were industry and university briefings and results of solicitations from the AIAA and the general public as part of the NASA outreach effort. Because of the variety of power needs in the SEI program, there will be a need for multiple power system technologies including solar, nuclear and electrochemical. Due to the high rocket masses required to propel payloads to the moon and beyond to Mars, there is great emphasis placed on the need for high power density and high energy density systems. Power system technology development work is needed results will determine the ultimate technology selections. 23 refs., 10 figs

  1. ODEPACK, Initial Value Problems of Ordinary Differential Equation System

    International Nuclear Information System (INIS)

    Hindmarsh, A.C.; Petzold, L.R.

    2005-01-01

    I - Description of program or function: ODEPACK is a collection of Fortran solvers for the initial value problem for ordinary differential equation systems. It consists of nine solvers, namely a basic solver called LSODE and eight variants of it -- LSODES, LSODA, LSODAR, LSODPK, LSODKR, LSODI, LSOIBT, and LSODIS. The collection is suitable for both stiff and non-stiff systems. It includes solvers for systems given in explicit form, dy/dt = f(t,y), and also solvers for systems given in linearly implicit form, A(t,y) dy/dt = g(t,y). Two of the solvers use general sparse matrix solvers for the linear systems that arise. Two others use iterative (preconditioned Krylov) methods instead of direct methods for these linear systems. The most recent addition is LSODIS, which solves implicit problems with general sparse treatment of all matrices involved. The ODEPACK solvers are written in standard Fortran 77, with a few exceptions, and with minimal machine dependencies. There are separate double and single precision versions of ODEPACK. The actual solver names are those given above with a prefix of D- or S- for the double or single precision version, respectively, i.e. DLSODE/SLSODE, etc. Each solver consists of a main driver subroutine having the same name as the solver and some number of subordinate routines. For each solver, there is also a demonstration program, which solves one or two simple problems in a somewhat self-checking manner. A. Solvers for explicitly given systems. For each of the following solvers, it is assumed that the ODEs are given explicitly, so that the system can be written in the form dy/dt = f(t,y), where y is the vector of dependent variables, and t is the independent variable. 1. LSODE (Livermore Solver for Ordinary Differential Equations) is the basic solver of the collection. It solves stiff and non-stiff systems of the form dy/dt = f. In the stiff case, it treats the Jacobian matrix df/dy as either a dense (full) or a banded matrix, and as

  2. An Optically-Coupled System for Quantitative Monitoring of MRI-Induced RF Currents into Long Conductors

    Science.gov (United States)

    Zanchi, Marta G.; Venook, Ross; Pauly, John M.; Scott, Greig C.

    2010-01-01

    The currents induced in long conductors such as guidewires by the radio frequency (RF) field in magnetic resonance imaging (MRI) are responsible for potentially dangerous heating of surrounding media, such as tissue. This paper presents an optically-coupled system with the potential to quantitatively measure the RF currents induced on these conductors. The system uses a self shielded toroid transducer and active circuitry to modulate a high speed LED transmitter. Plastic fiber guides the light to a photodiode receiver and transimpedance amplifier. System validation included a series of experiments with bare wires that compared wire tip heating by fluoroptic thermometers with the RF current sensor response. Validations were performed on a custom whole body 64 MHz birdcage test platform and on a 1.5T MRI scanner. With this system, a variety of phenomena were demonstrated including cable trap current attenuation, lossy dielectric Q-spoiling and even transverse electromagnetic wave node patterns. This system should find applications in studies of MRI RF safety for interventional devices such as pacemaker leads, and guidewires. In particular, variations of this device could potentially act as a realtime safety monitor during MRI guided interventions. PMID:19758855

  3. 3 Tesla proton MRI for the diagnosis of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia: initial results in comparison to HRCT.

    Science.gov (United States)

    Attenberger, U I; Morelli, J N; Henzler, T; Buchheidt, D; Fink, C; Schoenberg, S O; Reichert, M

    2014-01-01

    To evaluate the diagnostic accuracy of 3 Tesla proton MRI for the assessment of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia. In a prospective study, 3 Tesla MRI was performed in 19 febrile neutropenic patients (5 women, 14 men; mean age 61 years ± 14.2; range 23-77 years). All patients underwent high-resolution CT less than 24h prior to MRI. The MRI protocol (Magnetom Tim Trio, Siemens) included a T2-weighted HASTE sequence (TE/TR: 49 ms/∞, slice thickness 6mm) and a high-resolution 3D VIBE sequence with an ultra-short TETesla MRI with a sensitivity of 82.3% and a specificity of 78.6%, resulting in an overall accuracy of 88% (NPV/PPV 66.7%/89.5%). In 51 lobes (19 of 19 patients), pulmonary abnormalities visualized by MR were judged to be concordant in their location and in the lesion type identified by both readers. In 22 lobes (11 of 19 patients), no abnormalities were present on either MR or HRCT (true negative). In 6 lobes (5 of 19 patients), ground glass opacity areas were detected on MRI but were not visible on HRCT (false positives). In 11 lobes (7 of 19 patients), MRI failed to detect ground glass opacity areas identified by HRCT. However, since the abnormalities were disseminated in these patients, accurate treatment decisions were possible in every case based on MRI. In one case MRI showed a central area of cavitation, which was not visualized by HRCT. Infectious nodules and consolidations can be detected in neutropenic patients with acute myeloid leukemia with a sufficient diagnostic accuracy by 3 Tesla MRI. Detection of ground glass opacity areas is the main limitation of 3-Tesla MRI when compared to HRCT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. A multimodal MRI approach to identify and characterize microstructural brain changes in neuropsychiatric systemic lupus erythematosus.

    Science.gov (United States)

    Ercan, Ece; Ingo, Carson; Tritanon, Oranan; Magro-Checa, Cesar; Smith, Alex; Smith, Seth; Huizinga, Tom; van Buchem, Mark A; Ronen, Itamar

    2015-01-01

    Systemic lupus erythematosus (SLE) is an autoimmune disease with multi-organ involvement and results in neurological and psychiatric (NP) symptoms in up to 40% of the patients. To date, the diagnosis of neuropsychiatric systemic lupus erythematosus (NPSLE) poses a challenge due to the lack of neuroradiological gold standards. In this study, we aimed to better localize and characterize normal appearing white matter (NAWM) changes in NPSLE by combining data from two quantitative MRI techniques, diffusion tensor imaging (DTI) and magnetization transfer imaging (MTI). 9 active NPSLE patients (37 ± 13 years, all females), 9 SLE patients without NP symptoms (44 ± 11 years, all females), and 14 healthy controls (HC) (40 ± 9 years, all females) were included in the study. MTI, DTI and fluid attenuated inversion recovery (FLAIR) images were collected from all subjects on a 3 T MRI scanner. Magnetization transfer ratio (MTR), mean diffusivity (MD), fractional anisotropy (FA), radial diffusivity (RD), axial diffusivity (AD) maps and white matter lesion maps based on the FLAIR images were created for each subject. MTR and DTI data were then co-analyzed using tract-based spatial statistics and a cumulative lesion map to exclude lesions. Significantly lower MTR and FA and significantly higher AD, RD and MD were found in NPSLE compared to HC in NAWM regions. The differences in DTI measures and in MTR, however, were only moderately co-localized. Additionally, significant differences in DTI measures, but not in MTR, were found between NPSLE and SLE patients, suggesting that the underlying microstructural changes detected by MD are linked to the onset of NPSLE. The co-analysis of the anatomical distribution of MTI and DTI measures can potentially improve the diagnosis of NPSLE and contribute to the understanding of the underlying microstructural damage.

  5. MRI zoo

    DEFF Research Database (Denmark)

    Laustsen, Christoffer

    The basic idea was to use MRI to produce a sequence of 3D gray scale image slices of various animals, subsequentlyimaged with a clinical CT system. For this purpose, these animals were used: toad, lungfish, python snake and a horseshoe crab. Each animal was sacrificed according to standard...... visually inspected, both in 2D and 3D, and compared with photographs and anatomy atlases found at library and on the internet....

  6. Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

    Directory of Open Access Journals (Sweden)

    Brix L

    2016-10-01

    Full Text Available Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients were sedated due to pain related issues of their lower spine. The burns were caused by a combination of using a 3 Tesla MRI scanner and the inability to cry out during scanning. We would like to bring forward a message that even when using MRI conditional equipment, clinical staff must be extremely careful in order to secure safe image acquisition using MRI.

  7. Relationship of Hypertension, Blood Pressure, and Blood Pressure Control With White Matter Abnormalities in the Women’s Health Initiative Memory Study (WHIMS)—MRI Trial

    Science.gov (United States)

    Kuller, Lewis H.; Margolis, Karen L.; Gaussoin, Sarah A.; Bryan, Nick R.; Kerwin, Diana; Limacher, Marian; Wassertheil-Smoller, Sylvia; Williamson, Jeff; Robinson, Jennifer G.

    2010-01-01

    This paper evaluates the relationship of blood pressure (BP) levels at Women’s Health Initiative (WHI) baseline, treatment of hypertension, and white matter abnormalities among women in conjugated equine estrogen (CEE) and medroxyprogesterone acetate and CEE-alone arms. The WHI Memory Study—Magnetic Resonance Imaging (WHIMS-MRI) trial scanned 1424 participants. BP levels at baseline were significantly positively related to abnormal white matter lesion (WML) volumes. Participants treated for hypertension but who had BP ≥140/90 mm Hg had the greatest amount of WML volumes. Women with untreated BP ≥140/90 mm Hg had intermediate WML volumes. Abnormal WML volumes were related to hypertension in most areas of the brain and were greater in the frontal lobe than in the occipital, parietal, or temporal lobes. Level of BP at baseline was strongly related to amount of WML volumes. The results of the study reinforce the relationship of hypertension and BP control and white matter abnormalities in the brain. The evidence to date supports tight control of BP levels, especially beginning at younger and middle age as a possible and perhaps only way to prevent dementia. PMID:20433539

  8. Research on Initiation Sensitivity of Solid Explosive and Planer Initiation System

    Directory of Open Access Journals (Sweden)

    N Matsuo

    2016-09-01

    Full Text Available Firstly, recently, there are a lot of techniques being demanded for complex process, various explosive initiation method and highly accurate control of detonation are needed. In this research, the metal foil explosion using high current is focused attention on the method to obtain linear or planate initiation easily, and the main evaluation of metal foil explosion to initiate explosive was conducted. The explosion power was evaluated by observing optically the underwater shock wave generated from the metal foil explosion. Secondly, in high energy explosive processing, there are several applications, such as shock compaction, explosive welding, food processing and explosive forming. In these explosive applications, a high sensitive explosive has been mainly used. The high sensitive explosive is so dangerous, since it can lead to explosion suddenly. So, for developing explosives, the safety is the most important thing as well as low manufacturing cost and explosive characteristics. In this work, we have focused on the initiation sensitivity of a solid explosive and performed numerical analysis of sympathetic detonation. The numerical analysis is calculated by LS-DYNA 3D (commercial code. To understand the initiation reaction of an explosive, Lee-Tarver equation was used and impact detonation process was analyzed by ALE code. Configuration of simulation model is a quarter of circular cylinder. The donor type of explosive (SEP was used as initiation explosive. When the donor explosive is exploded, a shock wave is generated and it propagates into PMMA, air and metallic layers in order. During passing through the layers, the shock wave is attenuated and finally, it has influence on the acceptor explosive, Comp. B. Here, we evaluate the initiation of acceptor explosive and discuss about detonation pressure, reactive rate of acceptor explosive and attenuation of impact pressure.

  9. Brain PET and functional MRI: why simultaneously using hybrid PET/MR systems?

    Science.gov (United States)

    Cecchin, Diego; Palombit, Alessandro; Castellaro, Marco; Silvestri, Erica; Bui, Franco; Barthel, Henryk; Sabri, Osama; Corbetta, Maurizio; Bertoldo, Alessandra

    2017-12-01

    In the last 20 years growing attention has been devoted to multimodal imaging. The recent literature is rich of clinical and research studies that have been performed using different imaging modalities on both separate and integrated positron emission tomography (PET) and magnetic resonance (MR) scanners. However, today, hybrid PET/MR systems measure signals related to brain structure, metabolism, neurochemistry, perfusion, and neuronal activity simultaneously, i.e. in the same physiological conditions. A frequently raised question at meeting and symposia is: "Do we really need a hybrid PET/MR system? Are there any advantages over acquiring sequential and separate PET and MR scans?" The present paper is an attempt to answer these questions specifically in relation to PET combined with functional magnetic resonance imaging (fMRI) and arterial spin labeling. We searched (last update: June 2017) the databases PubMed, PMC, Google Scholar and Medline. We also included additional studies if they were cited in the selected articles. No language restriction was applied to the search, but the reviewed articles were all in English. Among all the retrieved articles, we selected only those performed using a hybrid PET/MR system. We found a total of 17 papers that were selected and discussed in three main groups according to the main radiopharmaceutical used: 18F-fluorodeoxyglucose (18F-FDG) (N.=8), 15O-water (15O-H2O) (N.=3) and neuroreceptors (N.=6). Concerning studies using 18F-FDG, simultaneous PET/fMRI revealed that global aspects of functional organization (e.g. graph properties of functional connections) are partially associated with energy consumption. There are remarkable spatial and functional similarities across modalities, but also discrepant findings. More work is needed on this point. There are only a handful of papers comparing blood flow measurements with PET 15O-H2O and MR arterial spin label (ASL) measures, and they show significant regional CBF differences

  10. Ultra-sensitive molecular MRI of cerebrovascular cell activation enables early detection of chronic central nervous system disorders

    International Nuclear Information System (INIS)

    Montagne, Axel; Gauberti, Maxime; Jullienne, Amandine; Briens, Aurelien; Docagne, Fabian; Vivien, Denis; Maubert, Eric; Macrez, Richard; Defer, Gilles; Raynaud, Jean-Sebastien; Louin, Gaelle; Buisson, Alain; Haelewyn, Benoit

    2012-01-01

    Since endothelial cells can be targeted by large contrast-carrying particles, molecular imaging of cerebrovascular cell activation is highly promising to evaluate the underlying inflammation of the central nervous system (CNS). In this study, we aimed to demonstrate that molecular magnetic resonance imaging (MRI) of cerebrovascular cell activation can reveal CNS disorders in the absence of visible lesions and symptoms. To this aim, we optimized contrast carrying particles targeting vascular cell adhesion molecule-1 and MRI protocols through both in vitro and in vivo experiments. Although, pre-contrast MRI images failed to reveal the ongoing pathology, contrast-enhanced MRI revealed hypoperfusion-triggered CNS injury in vascular dementia, unmasked amyloid-induced cerebrovascular activation in Alzheimer's disease and allowed monitoring of disease activity during experimental autoimmune encephalomyelitis. Moreover, contrast-enhanced MRI revealed the cerebrovascular cell activation associated with known risk factors of CNS disorders such as peripheral inflammation, ethanol consumption, hyperglycemia and aging. By providing a dramatically higher sensitivity than previously reported methods and molecular contrast agents, the technology described in the present study opens new avenues of investigation in the field of neuro-inflammation. (authors)

  11. Liver Imaging Reporting and Data System on CT and gadoxetic acid-enhanced MRI with diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Dong Ik; Jang, Kyung Mi; Kim, Seong Hyun; Kang, Tae Wook; Song, Kyoung Doo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    To assess major imaging features of Liver Imaging Reporting and Data System (LI-RADS) on contrast-enhanced CT and gadoxetic acid-enhanced MRI and to estimate whether the combination of signal intensity favouring HCC on hepatobiliary phase (HBP) and diffusion-weighted images (DWI) can act as a major feature in LI-RADS. Four hundred twenty one patients with 445 observations were included. Major features of LI-RADS on CT and MRI as well as HBP and DWI features were assessed. Diagnostic performances of LR-5 according to LI-RADS v2014 and modified LI-RADS which incorporate combination of HBP and DWI were assessed. Pairwise comparisons of the receiver operating characteristic (ROC) curves were performed. For HCCs, capsule appearance had the highest rate of discordance between CT and MRI (32.7%), followed by washout appearance (22.2%). Specificity (75%) of LR-5 of LI-RADS v2014 was lower than that (77.1-79.2%) of modified LI-RADS. Area under the ROC curve of modified LI-RADS (0.755-0.775) was not significantly different from that of LI-RADS v 2014 (0.709) (p > 0.05). There were substantial discordances between CT and MRI for capsule and washout appearances in hepatic observations, and combination of gadoxetic acid-enhanced MRI and DWI might be able to be incorporated as a major feature of LI-RADS. (orig.)

  12. Initial Progress in Developing the New ICSU World Data System

    Science.gov (United States)

    Minster, J. H.; Capitaine, N.; Clark, D. M.; Mokrane, M.

    2009-12-01

    On October 24, 2008, at the 29th International Council for Science (ICSU) General Assembly in Maputo, Mozambique, a decision to form a new ICSU World Data System (WDS) was taken. The new ICSU World Data System (WDS) will replace the framework within which the current ICSU World Data Centers (WDCs) and services of the Federation of Astronomical and Geophysical data-analysis Services (FAGS) are currently organized. The transition from the old organizations to the new WDS was facilitated by the ICSU ad-hoc WDS Transition Team which developed a white paper with recommendations for the new WDS Scientific Committee (WDS-SC). The WDS-SC was appointed by ICSU and reports to the Executive Board and the General Assembly of ICSU. The WDSSC met for the first time in October 2009. WDS-SC shall be the governing body of WDS with the following tasks: 1) to ensure that the WDS clearly supports ICSU’s mission and objectives by ensuring the long-term stewardship and provision of quality-assessed data and data services to the international science community and other stakeholders; 2) to develop, and keep under continuous review, an implementation plan for the creation of the WDS by incorporating the ICSU WDCs, the Services of FAGS and a wide range of other data centers and services; 3) to define agreed standards, establish and oversee the procedures for the review and accreditation of existing and new facilities; 4) to monitor the geographic and disciplinary scope of the system and to develop strategies for the recruitment and establishment of new WDS facilities as necessary; 5) to consider resource issues and provide guidance on funding mechanisms for facilities within WDS when appropriate; 6) to develop strong cooperative links with the ICSU Strategic Coordinating Committee on Information and Data (SCCID);and 7) to cooperate closely with the ICSU Committee on Data for Science and Technology (CODATA). WDS development will proceed from these initial concepts: history and legacy of

  13. Comparison of contrast enhanced MR-angiography-MRI and digital subtraction angiography in the evaluation of pancreas and/or kidney transplantation patients : initial experience

    NARCIS (Netherlands)

    Boeve, WJ; Kok, T; Tegzess, Adam; van Son, WJ; Ploeg, RJ; Sluiter, WJ; Kamman, RL

    To evaluate whether combined contrast enhanced MRA and MRI (ce-MRA-MRI) has the potential to replace intra-arterial DSA (i.a.DSA) in patients with impaired graft function or suspected of vascular complications after pancreas and/or kidney transplantation. 7 patients after combined pancreas-kidney

  14. MRI in psychiatry

    International Nuclear Information System (INIS)

    Mulert, Christoph; Shenton, Martha E.

    2014-01-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  15. MRI in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Mulert, Christoph [UKE, Hamburg (Germany). Psychiatry Neuroimaging Branch; Shenton, Martha E. (ed.) [Harvard Medical School, Boston, MA (United States). Dept. of Psychiatry and Radiology

    2014-07-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  16. Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.

    Science.gov (United States)

    Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng

    2017-10-01

    Monitoring tumor response during the course of treatment and adaptively modifying treatment plan based on tumor biological feedback may represent a new paradigm for radiotherapy. Diffusion MRI has shown great promises in assessing and predicting tumor response to radiotherapy. However, the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) technique suffers from limited resolution, severe distortion, and possibly inaccurate ADC at low field strength. The purpose of this work was to develop a reliable, accurate and distortion-free diffusion MRI technique that is practicable for longitudinal tumor response evaluation and adaptive radiotherapy on a 0.35 T MRI-guided radiotherapy system. A diffusion-prepared turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging sequence on a 0.35 T MRI-guided radiotherapy system (ViewRay). A spatial integrity phantom was used to quantitate and compare the geometric accuracy of the two diffusion sequences for three orthogonal orientations. The apparent diffusion coefficient (ADC) accuracy was evaluated on a diffusion phantom under both 0 °C and room temperature to cover a diffusivity range between 0.40 × 10 -3 and 2.10 × 10 -3 mm 2 /s. Ten room temperature measurements repeated on five different days were conducted to assess the ADC reproducibility of DP-TSE. Two glioblastoma (GBM) and six sarcoma patients were included to examine the in vivo feasibility. The target registration error (TRE) was calculated to quantitate the geometric accuracy where structural CT or MR images were co-registered to the diffusion images as references. ADC maps from DP-TSE and DW-ssEPI were calculated and compared. A tube phantom was placed next to patients not treated on ViewRay, and ADCs of this reference tube were also compared. The proposed DP-TSE passed the spatial integrity test (< 1 mm within 100 mm radius and < 2 mm within 175 mm radius

  17. Toyota production system quality improvement initiative improves perioperative antibiotic therapy.

    Science.gov (United States)

    Burkitt, Kelly H; Mor, Maria K; Jain, Rajiv; Kruszewski, Matthew S; McCray, Ellesha E; Moreland, Michael E; Muder, Robert R; Obrosky, David Scott; Sevick, Mary Ann; Wilson, Mark A; Fine, Michael J

    2009-09-01

    To assess the role of a Toyota production system (TPS) quality improvement (QI) intervention on appropriateness of perioperative antibiotic therapy and in length of hospital stay (LOS) among surgical patients. Pre-post quasi-experimental study using local and national retrospective cohorts. We used TPS methods to implement a multifaceted intervention to reduce nosocomial methicillin-resistant Staphylococcus aureus infections on a Veterans Affairs surgical unit, which led to a QI intervention targeting appropriate perioperative antibiotic prophylaxis. Appropriate perioperative antibiotic therapy was defined as selection of the recommended antibiotic agents for a duration not exceeding 24 hours from the time of the operation. The local computerized medical record system was used to identify patients undergoing the 25 most common surgical procedures and to examine changes in appropriate antibiotic therapy and LOS over time. Overall, 2550 surgical admissions were identified from the local computerized medical records. The proportion of surgical admissions receiving appropriate perioperative antibiotics was significantly higher (P <.01) in 2004 after initiation of the TPS intervention (44.0%) compared with the previous 4 years (range, 23.4%-29.8%) primarily because of improvements in compliance with antibiotic therapy duration rather than appropriate antibiotic selection. There was no statistically significant decrease in LOS over time. The use of TPS methods resulted in a QI intervention that was associated with an increase in appropriate perioperative antibiotic therapy among surgical patients, without affecting LOS.

  18. Scientific investigation plan for initial engineered barrier system field tests

    International Nuclear Information System (INIS)

    Wunan Lin.

    1993-02-01

    The purpose of this Scientific Investigation Plan (SIP) is to describe tests known as Initial Engineered Barrier System Field Tests (IEBSFT) and identified by Work Breakdown Structure as WBS 1.2.2.2.4. The IEBSFT are precursors to the Engineered Barrier System Field Test (EBSFT), WBS 1.2.2.2.4, to be conducted in the Exploratory Study Facility (ESF) at Yucca Mountain. The EBSFT and IEBSFT are designed to provide information on the interaction between waste packages (simulated by heated containers) and the surrounding rock mass, its vadose water, and infiltrated water. Heater assemblies will be installed in drifts or boreholes openings and heated to measure moisture movement during heat-up and subsequent cool-down of the rock mass. In some of the tests, infiltration of water into the heated rock mass will be studied. Throughout the heating and cooling cycle, instruments installed in the rock will monitor such parameters as temperature, moisture content, concentration of some chemical species, and stress and strain. Rock permeability measurements, rock and fluid (water and gas) sampling, and fracture pattern measurements will also be made before and after the test

  19. Robot-assisted biopsies in a high-field MRI system. First clinical results

    International Nuclear Information System (INIS)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S.; Czerny, C.

    2012-01-01

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  20. The distributed neural system for top-down letter processing: an fMRI study

    Science.gov (United States)

    Liu, Jiangang; Feng, Lu; Li, Ling; Tian, Jie

    2011-03-01

    This fMRI study used Psychophysiological interaction (PPI) to investigate top-down letter processing with an illusory letter detection task. After an initial training that became increasingly difficult, participant was instructed to detect a letter from pure noise images where there was actually no letter. Such experimental paradigm allowed for isolating top-down components of letter processing and minimizing the influence of bottom-up perceptual input. A distributed cortical network of top-down letter processing was identified by analyzing the functional connectivity patterns of letter-preferential area (LA) within the left fusiform gyrus. Such network extends from the visual cortex to high level cognitive cortexes, including the left middle frontal gyrus, left medial frontal gyrus, left superior parietal gyrus, bilateral precuneus, and left inferior occipital gyrus. These findings suggest that top-down letter processing contains not only regions for processing of letter phonology and appearance, but also those involved in internal information generation and maintenance, and attention and memory processing.

  1. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  2. Ultra-high field MRI: Advancing systems neuroscience towards mesoscopic human brain function

    NARCIS (Netherlands)

    Dumoulin, Serge O; Fracasso, A.; Van der Zwaag, W.; Siero, Jeroen C W; Petridou, Natalia

    2018-01-01

    Human MRI scanners at ultra-high magnetic field strengths of 7 T and higher are increasingly available to the neuroscience community. A key advantage brought by ultra-high field MRI is the possibility to increase the spatial resolution at which data is acquired, with little reduction in image

  3. Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

    Science.gov (United States)

    Tao, Shengzhen; Weavers, Paul T; Trzasko, Joshua D; Shu, Yunhong; Huston, John; Lee, Seung-Kyun; Frigo, Louis M; Bernstein, Matt A

    2017-06-01

    To develop a gradient pre-emphasis scheme that prospectively counteracts the effects of the first-order concomitant fields for any arbitrary gradient waveform played on asymmetric gradient systems, and to demonstrate the effectiveness of this approach using a real-time implementation on a compact gradient system. After reviewing the first-order concomitant fields that are present on asymmetric gradients, we developed a generalized gradient pre-emphasis model assuming arbitrary gradient waveforms to counteract their effects. A numerically straightforward, easily implemented approximate solution to this pre-emphasis problem was derived that was compatible with the current hardware infrastructure of conventional MRI scanners for eddy current compensation. The proposed method was implemented on the gradient driver subsystem, and its real-time use was tested using a series of phantom and in vivo data acquired from two-dimensional Cartesian phase-difference, echo-planar imaging, and spiral acquisitions. The phantom and in vivo results demonstrated that unless accounted for, first-order concomitant fields introduce considerable phase estimation error into the measured data and result in images with spatially dependent blurring/distortion. The resulting artifacts were effectively prevented using the proposed gradient pre-emphasis. We have developed an efficient and effective gradient pre-emphasis framework to counteract the effects of first-order concomitant fields of asymmetric gradient systems. Magn Reson Med 77:2250-2262, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Initial clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1997-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from the MRI study were reconstructed to precisely match the CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also estimated. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair in comparison. The patient study showed a mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI, respectively. The difference in prostate location with the two studies usually differed at the base and at the apex of the prostate. On the transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone. Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. CT-MRI image fusion technique provides valuable supplements to CT technology for more precise targeting of the prostate cancer

  5. Perceptual Characterization of the Macronutrient Picture System (MaPS for Food Image fMRI

    Directory of Open Access Journals (Sweden)

    Jill L. King

    2018-01-01

    Full Text Available Food image fMRI paradigms are used widely for investigating the neural basis of ingestive behavior. However, these paradigms have not been validated in terms of ingestive behavior constructs, engagement of food-relevant neural systems, or test-retest reliability, making the generalizability of study findings unclear. Therefore, we validated the Macronutrient Picture System (MaPS (McClernon et al., 2013, which includes food images from the six categories represented in the Geiselman Food Preference Questionnaire (FPQ (Geiselman et al., 1998. Twenty-five healthy young adults (n = 21 female, mean age = 20.6 ± 1.1 years, mean BMI = 22.1 ± 1.9 kg/m2 rated the MaPS images in terms of visual interest, appetitive quality, nutrition, emotional valence, liking, and frequency of consumption, and completed the FPQ. In a second study, 12 individuals (n=8 female, mean age = 25.0 ± 6.5 years, mean BMI = 28.2 ± 8.7 kg/m2 viewed MaPS and control images (vegetables and non-food during two separate 3T BOLD fMRI scans after fasting overnight. Intuitively, high fat/high sugar (HF/HS and high fat/high complex carbohydrate (HF/HCCHO images achieved higher liking and appetitive ratings, and lower nutrition ratings, than low fat/low complex carbohydrate/high protein (LF/LCHO/HP images on average. Within each food category, FPQ scores correlated strongly with MaPS image liking ratings (p < 0.001. Brain activation differences between viewing images of HF/HS and vegetables, and between HF/HCCHO and vegetables, were seen in several reward-related brain regions (e.g., putamen, insula, and medial frontal gyrus. Intra-individual, inter-scan agreement in a summary measure of brain activation differences in seven reward network regions of interest was high (ICC = 0.61, and was even higher when two distinct sets of food images with matching visual ratings were shown in the two scans (ICC = 0.74. These results suggest that the MaPS provides valid representation of food

  6. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  7. A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI.

    Science.gov (United States)

    Bohning, Daryl E; Denslow, S; Bohning, P A; Walker, J A; George, M S

    2003-11-01

    Transcranial magnetic stimulation (TMS) can be interleaved with fMRI to visualize regional brain activity in response to direct, non-invasive, cortical stimulation, making it a promising tool for studying brain function. A major practical difficulty is accurately positioning the TMS coil within the MRI scanner for stimulating a particular area of brain cortex. The objective of this work was to design and build a self-contained hardware/software system for MR-guided TMS coil positioning in interleaved TMS/fMRI studies. A compact, manually operated, articulated TMS coil positioner/holder with 6 calibrated degrees of freedom was developed for use inside a cylindrical RF head coil, along with a software package for transforming between MR image coordinates, MR scanner space coordinates, and positioner/holder settings. Phantom calibration studies gave an accuracy for positioning within setups of dx=+/-1.9 mm, dy=+/-1.4 mm, dz=+/-0.8 mm and a precision for multiple setups of dx=+/-0.8 mm, dy=+/-0.1 mm, dz=+/-0.1 mm. This self-contained, integrated MR-guided TMS system for interleaved TMS/fMRI studies provides fast, accurate location of motor cortex stimulation sites traditionally located functionally, and a means of consistent, anatomy-based TMS coil positioning for stimulation of brain areas without overt response.

  8. Integrated modeling of natural and human systems - problems and initiatives

    Science.gov (United States)

    Kessler, H.; Giles, J.; Gunnink, J.; Hughes, A.; Moore, R. V.; Peach, D.

    2009-12-01

    's system, e.g. the flow of groundwater to an abstraction borehole or the availability of water for irrigation. Particular problems arise when model data from two or more disciplines are incompatible in terms of data formats, scientific concepts or language. Other barriers include the cultural segregation within and between science disciplines as well as impediments to data exchange due to ownership and copyright restrictions. OpenMI and GeoSciML are initiatives that are trying to overcome these barriers by building international communities that share vocabularies and data formats. This paper will give examples of the successful merging of geological and hydrological models from the UK and the Netherlands and will introduce the vision of an open Environmental Modelling Platform which aims to link data, knowledge and concepts seamlessly to numerical process models. Last but not least there is an urgent need to create a Subsurface Management System akin to a Geographic Information System in which all results of subsurface modelling can be visualised and analysed in an integrated manner.

  9. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI ...

  10. Multiparametric MRI of the prostate: diagnostic performance and interreader agreement of two scoring systems.

    Science.gov (United States)

    Lin, Wei-Ching; Muglia, Valdair F; Silva, Gyl E B; Chodraui Filho, Salomão; Reis, Rodolfo B; Westphalen, Antonio C

    2016-06-01

    To compare the diagnostic accuracies and interreader agreements of the Prostate Imaging Reporting and Data System (PI-RADS) v. 2 and University of California San Francisco (UCSF) multiparametric prostate MRI scale for diagnosing clinically significant prostate cancer. This institutional review board-approved retrospective study included 49 males who had 1.5 T endorectal MRI and prostatectomy. Two radiologists scored suspicious lesions on MRI using PI-RADS v. 2 and the UCSF scale. Percent agreement, 2 × 2 tables and the area under the receiver operating characteristic curves (Az) were used to assess and compare the individual and overall scores of these scales. Interreader agreements were estimated with kappa statistics. Reader 1 (R1) detected 78 lesions, and Reader 2 (R2) detected 80 lesions. Both identified 52 of 65 significant cancers. The Az for PI-RADS v. 2 and UCSF scale for R1 were 0.68 and 0.69 [T2 weighted imaging (T2WI)], 0.75 and 0.68 [diffusion-weighted imaging (DWI)] and 0.64 and 0.72 (overall score), respectively, and were 0.72 and 0.75 (T2WI), 0.73 and 0.67 (DWI) and 0.66 and 0.75 (overall score) for R2. The dynamic contrast-enhanced percent agreements between scales were 100% (R1) and 95% (R2). PI-RADS v. 2 DWI of R1 performed better than UCSF DWI (Az = 0.75 vs Az = 0.68; p = 0.05); no other differences were found. The interreader agreements were higher for PI-RADS v. 2 (T2WI: 0.56 vs 0.42; DWI: 0.60 vs 0.46; overall: 0.61 vs 0.42). The UCSF approach to derive the overall PI-RADS v. 2 scores increased the Az for the identification of significant cancer (R1 to 0.76, p < 0.05; R2 to 0.71, p = 0.35). Although PI-RADS v. 2 DWI score may have a higher discriminatory performance than the UCSF scale counterpart to diagnose clinically significant cancer, the utilization of the UCSF scale weighing system for the integration of PI-RADS v. 2 individual parameter scores improved the accuracy its overall score. PI-RADS v. 2 is

  11. Conservatively treated knee injury is associated with knee cartilage matrix degeneration measured with MRI-based T2 relaxation times. Data from the osteoarthritis initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Felix C. [University of California San Francisco, Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Technical University of Munich, Department of Radiology, Munich (Germany); Neumann, Jan; Heilmeier, Ursula; Joseph, Gabby B.; Link, Thomas M. [University of California San Francisco, Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Nevitt, Michael C.; McCulloch, Charles E. [University of California San Francisco, Department of Epidemiology and Biostatistics, San Francisco, CA (United States)

    2018-01-15

    To investigate the association of cartilage degeneration with previous knee injuries not undergoing surgery, determined by morphologic and quantitative 3-T magnetic resonance imaging (MRI). We performed a nested cross-sectional study of right knee MRIs from participants in the Osteoarthritis Initiative (OAI) aged 45-79 with baseline Kellgren-Lawrence score of 0-2. Cases were 142 right knees of patients with self-reported history of injury limiting the ability to walk for at least 2 days. Controls were 426 right knees without history of injury, frequency-matched to cases on age, BMI, gender, KL scores and race (1:3 ratio). Cases and controls were compared using covariate-adjusted linear regression analysis, with the outcomes of region-specific T2 mean, laminar analysis and heterogeneity measured by texture analysis to investigate early cartilage matrix abnormalities and the Whole-Organ Magnetic Resonance Imaging Score (WORMS) to investigate morphologic knee lesions. Compared to control subjects, we found significantly higher mean T2 values in the injury [lateral tibia (28.10 ms vs. 29.11 ms, p = 0.001), medial tibia (29.70 ms vs. 30.40 ms, p = 0.014) and global knee cartilage (32.73 ms vs. 33.29 ms, p = 0.005)]. Injury subjects also had more heterogeneous cartilage as measured by GLCM texture contrast, variance and entropy (p < 0.05 in 14 out of 18 texture parameters). WORMS gradings were not significantly different between the two groups (p > 0.05). A history of knee injury not treated surgically is associated with higher and more heterogeneous T2 values, but not with morphologic knee abnormalities. Our findings suggest that significant, conservatively treated knee injuries are associated with permanent cartilage matrix abnormalities. (orig.)

  12. Conservatively treated knee injury is associated with knee cartilage matrix degeneration measured with MRI-based T2 relaxation times. Data from the osteoarthritis initiative

    International Nuclear Information System (INIS)

    Hofmann, Felix C.; Neumann, Jan; Heilmeier, Ursula; Joseph, Gabby B.; Link, Thomas M.; Nevitt, Michael C.; McCulloch, Charles E.

    2018-01-01

    To investigate the association of cartilage degeneration with previous knee injuries not undergoing surgery, determined by morphologic and quantitative 3-T magnetic resonance imaging (MRI). We performed a nested cross-sectional study of right knee MRIs from participants in the Osteoarthritis Initiative (OAI) aged 45-79 with baseline Kellgren-Lawrence score of 0-2. Cases were 142 right knees of patients with self-reported history of injury limiting the ability to walk for at least 2 days. Controls were 426 right knees without history of injury, frequency-matched to cases on age, BMI, gender, KL scores and race (1:3 ratio). Cases and controls were compared using covariate-adjusted linear regression analysis, with the outcomes of region-specific T2 mean, laminar analysis and heterogeneity measured by texture analysis to investigate early cartilage matrix abnormalities and the Whole-Organ Magnetic Resonance Imaging Score (WORMS) to investigate morphologic knee lesions. Compared to control subjects, we found significantly higher mean T2 values in the injury [lateral tibia (28.10 ms vs. 29.11 ms, p = 0.001), medial tibia (29.70 ms vs. 30.40 ms, p = 0.014) and global knee cartilage (32.73 ms vs. 33.29 ms, p = 0.005)]. Injury subjects also had more heterogeneous cartilage as measured by GLCM texture contrast, variance and entropy (p < 0.05 in 14 out of 18 texture parameters). WORMS gradings were not significantly different between the two groups (p > 0.05). A history of knee injury not treated surgically is associated with higher and more heterogeneous T2 values, but not with morphologic knee abnormalities. Our findings suggest that significant, conservatively treated knee injuries are associated with permanent cartilage matrix abnormalities. (orig.)

  13. 3 Tesla proton MRI for the diagnosis of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia: Initial results in comparison to HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I., E-mail: ulrike.attenberger@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Morelli, J.N. [Scott and White Hospital, Texas A and M Health Sciences Center, Temple (United States); Henzler, T. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Buchheidt, D. [Department of Hematology and Oncology, University Medical Center Mannheim (Germany); Fink, C. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany); Department of Radiology, AKH Celle, Celle (Germany); Schoenberg, S.O.; Reichert, M. [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim (Germany)

    2014-01-15

    Purpose: To evaluate the diagnostic accuracy of 3 Tesla proton MRI for the assessment of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia. Material and methods: In a prospective study, 3 Tesla MRI was performed in 19 febrile neutropenic patients (5 women, 14 men; mean age 61 years ± 14.2; range 23–77 years). All patients underwent high-resolution CT less than 24 h prior to MRI. The MRI protocol (Magnetom Tim Trio, Siemens) included a T2-weighted HASTE sequence (TE/TR: 49 ms/∞, slice thickness 6 mm) and a high-resolution 3D VIBE sequence with an ultra-short TE < 1 ms (TE/TR 0.8/2.9 ms, slice thickness 2 mm). The VIBE sequence was examined before and after intravenous injection of 0.1 mmol/kg gadoterate meglumine (Dotarem, Guerbet). The presence of pulmonary abnormalities, their location within the lung, and lesion type (nodules, consolidations, glass opacity areas) were analyzed by one reader and compared to the findings of HRCT, which was evaluated by a second independent radiologist who served as the reference standard. The findings were compared per lobe in each patient and rated as true positive (TP) findings if all three characteristics (presence, location, and lesion type) listed above were concordant to HRCT. Results: Pulmonary abnormalities were characterized by 3 Tesla MRI with a sensitivity of 82.3% and a specificity of 78.6%, resulting in an overall accuracy of 88% (NPV/PPV 66.7%/89.5%). In 51 lobes (19 of 19 patients), pulmonary abnormalities visualized by MR were judged to be concordant in their location and in the lesion type identified by both readers. In 22 lobes (11 of 19 patients), no abnormalities were present on either MR or HRCT (true negative). In 6 lobes (5 of 19 patients), ground glass opacity areas were detected on MRI but were not visible on HRCT (false positives). In 11 lobes (7 of 19 patients), MRI failed to detect ground glass opacity areas identified by HRCT. However, since the abnormalities were

  14. High performance MRI simulations of motion on multi-GPU systems.

    Science.gov (United States)

    Xanthis, Christos G; Venetis, Ioannis E; Aletras, Anthony H

    2014-07-04

    MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment. Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined. Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems. MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation

  15. Signal to noise ratio (SNR) and image uniformity: an estimate of performance of magnetic resonance imaging (MRI) system

    International Nuclear Information System (INIS)

    Narayan, P.; Suri, S.; Choudhary, S.R.

    2001-01-01

    In most general definition, noise in an image, is any variation that represents a deviation from truth. Noise sources in MRI can be systematic or random and statistical in nature. Data processing algorithms that smooth and enhance the edges by non-linear intensity assignments among other factors can affect the distribution of statistical noise. The SNR and image uniformity depends on the various parameters of NMR imaging system (viz. General system calibration, Gain coil tuning, AF shielding, coil loading, image processing and scan parameters like TE, TR, interslice distance, slice thickness, pixel size and matrix size). A study on SNR and image uniformity have been performed using standard head AF coil with different TR and the estimates of their variation are presented. A comparison between different techniques has also been evaluated using standard protocol of the Siemens Magnetom Vision Plus MRI system

  16. Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging

    International Nuclear Information System (INIS)

    Thornton, A.F. Jr.; Ten Haken, R.K.; Gerhardsson, A.; Correll, M.

    1991-01-01

    A mask/marker immobilization system for the routine radiation therapy treatment of head and neck disease is described, utilizing a commercially available thermoplastic mesh, indexed and mounted for a rigid frame attached to the therapy couch. Designed to permit CT, MRI, and PET diagnostics scans of the patient to be performed in the simulation and treatment position employing the same mask, the system has been tested in order to demonstrate the reproducibility of immobilization throughout a radical course of irradiation. Three-dimensional analysis of patient position over an 8-week course of daily radiation treatment has been performed for 9 patients from digitization of anatomic points identified on orthogonal radiographs. Studies employing weekly constructed system permits rapid mask formation to be performed on the treatment simulator, resulting in an immobilization device comparable to masks produced with vacuum-forming techniques. Details of motion analysis and central axis CT, MRI, and PET markers are offered. (author). 16 refs.; 3 figs

  17. Quality assurance in functional MRI

    DEFF Research Database (Denmark)

    Liu, Thomas T; Glover, Gary H; Mueller, Bryon A

    2015-01-01

    Over the past 20 years, functional magnetic resonance imaging (fMRI) has ben- efited greatly from improvements in MRI hardware and software. At the same time, fMRI researchers have pushed the technical limits of MRI systems and greatly in- fluenced the development of state-of-the-art systems...... consistent data throughout the course of a study, and consistent stability across time and sites is needed to allow data from different time periods or acquisition sites to be optimally integrated....

  18. [18F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale; Ruhlmann, Verena; Buderath, Paul; Aktas, Bahriye; Heusch, Philipp; Kraff, Oliver

    2015-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [ 18 F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  19. [{sup 18}F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Clinic for Nuclear Medicine, Essen (Germany); Buderath, Paul; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Clinic for Obstetrics and Gynecology, Essen (Germany); Heusch, Philipp [University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-01-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [{sup 18}F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  20. Activation of Visuomotor Systems during Visually Guided Movements: A Functional MRI Study

    Science.gov (United States)

    Ellermann, Jutta M.; Siegal, Joel D.; Strupp, John P.; Ebner, Timothy J.; Ugurbil, Kâmil

    1998-04-01

    The dorsal stream is a dominant visuomotor pathway that connects the striate and extrastriate cortices to posterior parietal areas. In turn, the posterior parietal areas send projections to the frontal primary motor and premotor areas. This cortical pathway is hypothesized to be involved in the transformation of a visual input into the appropriate motor output. In this study we used functional magnetic resonance imaging (fMRI) of the entire brain to determine the patterns of activation that occurred while subjects performed a visually guided motor task. In nine human subjects, fMRI data were acquired on a 4-T whole-body MR system equipped with a head gradient coil and a birdcage RF coil using aT*2-weighted EPI sequence. Functional activation was determined for three different tasks: (1) a visuomotor task consisting of moving a cursor on a screen with a joystick in relation to various targets, (2) a hand movement task consisting of moving the joystick without visual input, and (3) a eye movement task consisting of moving the eyes alone without visual input. Blood oxygenation level-dependent (BOLD) contrast-based activation maps of each subject were generated using period cross-correlation statistics. Subsequently, each subject's brain was normalized to Talairach coordinates, and the individual maps were compared on a pixel by pixel basis. Significantly activated pixels common to at least four out of six subjects were retained to construct the final functional image. The pattern of activation during visually guided movements was consistent with the flow of information from striate and extrastriate visual areas, to the posterior parietal complex, and then to frontal motor areas. The extensive activation of this network and the reproducibility among subjects is consistent with a role for the dorsal stream in transforming visual information into motor behavior. Also extensively activated were the medial and lateral cerebellar structures, implicating the cortico

  1. Clinical evaluation of a computer-aided diagnosis system for determining cancer aggressiveness in prostate MRI

    International Nuclear Information System (INIS)

    Litjens, Geert J.S.; Barentsz, Jelle O.; Karssemeijer, Nico; Huisman, Henkjan J.

    2015-01-01

    To investigate the added value of computer-aided diagnosis (CAD) on the diagnostic accuracy of PIRADS reporting and the assessment of cancer aggressiveness. Multi-parametric MRI and histopathological outcome of MR-guided biopsies of a consecutive set of 130 patients were included. All cases were prospectively PIRADS reported and the reported lesions underwent CAD analysis. Logistic regression combined the CAD prediction and radiologist PIRADS score into a combination score. Receiver-operating characteristic (ROC) analysis and Spearman's correlation coefficient were used to assess the diagnostic accuracy and correlation to cancer grade. Evaluation was performed for discriminating benign lesions from cancer and for discriminating indolent from aggressive lesions. In total 141 lesions (107 patients) were included for final analysis. The area-under-the-ROC-curve of the combination score was higher than for the PIRADS score of the radiologist (benign vs. cancer, 0.88 vs. 0.81, p = 0.013 and indolent vs. aggressive, 0.88 vs. 0.78, p < 0.01). The combination score correlated significantly stronger with cancer grade (0.69, p = 0.0014) than the individual CAD system or radiologist (0.54 and 0.58). Combining CAD prediction and PIRADS into a combination score has the potential to improve diagnostic accuracy. Furthermore, such a combination score has a strong correlation with cancer grade. (orig.)

  2. MRI and CT in alveolar echinococcosis of the liver

    International Nuclear Information System (INIS)

    Duewell, S.; Marincek, B.; Schulthess, G.K. von; Ammann, R.; Zurich Univ.

    1990-01-01

    To compare the value of MRI and CT in evaluating hepatic alveolar echinococcosis a study was conducted on 30 patients. The liver was initially affected in all patients. At the time of examination, 15 patients had undergone partial liver resection. MRI showed no advantage over CT in demonstrating an echinococcal mass lesion. MRI was superior in identifying concomitant pathological changes of the intrahepatic and extrahepatic venous system due to the intrinsic contrast of vascular structures. However, CT was superior in identifying calcifications, an important attribute of the disease. MRI should only be used in imaging alveolar echinococcosis of the liver if diagnostic questions remain open after CT, in particular questions concerning venous pathology. MRI may also be used to replace CT in patients with a contraindication to urographic contrast material. (orig.) [de

  3. MRI of the Chest

    Medline Plus

    Full Text Available ... provides movie-like sequential imaging of the cardiovascular system that is important to assess the health and ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  4. MRI-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture for treatment of cervical disc herniation: an initial experience

    International Nuclear Information System (INIS)

    Liu Ming; Li Chengli; Lu Yubo; Huang Jie; Song Jiqing; Li Lei; Bao Shougang; Cao Qianqian; Wu Lebin

    2010-01-01

    Objective: To explore the value of MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture for treatment of cervical disc herniation. Methods: Eight herniated cervical discs in 7 patients were diagnosed by MRI, inclluding 5 discs of lateral protruding type, 2 discs of paramedian protruding type and one disc of central protruding type. All patients underwent MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture. The procedures were guided by a set of 0.23 T open MR system mounted with iPath 200 optical tracking system. The herniated portion of the disc was punctured with a 14 G MR-comparible needle in the healthy side via anterolateral oblique route. The interventional steps were as follows: firstly, cut herniated part with percutaneous discectomy probe and inject 2ml oxygen-ozone mixture of 60 μg/ml; secondly, retreat the needle to the disc center, resect nucleus pulposus, and inject 2 ml oxygen-ozone mixture of 60 μg/ml; secondly, retreat the needle to the disc center, resect nucleus pulposus, and inject 2 ml oxygen-ozone mixture of 60 μg/ml. All patients were followed up for 6 months, with 4 patients by telephone and 3 patients in outpatient clinic. The effect of treatment was evaluated according to Williams postoperative assessment standard. Results: All procedures were performed successfully. The clinical outcome was evaluated as excellent in 5 cases, good in 1 cases and fair in 1 case. The total ratio of excellent and good was 85.7%. No serious complication occurred expect 1 case with intraoperative paroxysmal pain. Conclusion: MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture was a safe, effective and minimally invasive method for the treatment of cervical disc herniation. (authors)

  5. MRI of neonatal encephalopathy

    International Nuclear Information System (INIS)

    Khong, P.L.; Lam, B.C.C.; Tung, H.K.S.; Wong, V.; Chan, F.L.; Ooi, G.C.

    2003-01-01

    We present the magnetic resonance imaging (MRI) findings in neonatal encephalopathy, including hypoxic-ischaemic encephalopathy, perinatal/neonatal stroke, metabolic encephalopathy from inborn errors of metabolism, congenital central nervous system infections and birth trauma. The applications of advanced MRI techniques, such as diffusion-weighted imaging and magnetic resonance spectroscopy are emphasized

  6. Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI.

    Science.gov (United States)

    Düppenbecker, Peter M; Weissler, Bjoern; Gebhardt, Pierre; Schug, David; Wehner, Jakob; Marsden, Paul K; Schulz, Volkmar

    2016-02-01

    Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure. This is the first detector design that allows the operation of digital SiPMs simultaneously inside an MRI system. We tested and optimized the MRI-compatibility of our detector stack on a laboratory test bench as well as in combination with a Philips Achieva 3 T MRI system. Our design clearly reduces distortions of the static magnetic field compared to a conventional design. The MRI static magnetic field causes weak and directional drift effects on voltage regulators, but has no direct impact on detector performance. MRI gradient switching initially degraded energy and timing resolution. Both distortions could be ascribed to voltage variations induced on the bias and the FPGA core voltage supply respectively. Based on these findings, we improved our detector design and our final design shows virtually no energy or timing degradations, even during heavy and continuous MRI gradient switching. In particular, we found no evidence that the performance of the DPC 3200-22 digital SiPM itself is degraded by the MRI system.

  7. Benchtop-magnetic resonance imaging (BT-MRI) characterization of push-pull osmotic controlled release systems.

    Science.gov (United States)

    Malaterre, Vincent; Metz, Hendrik; Ogorka, Joerg; Gurny, Robert; Loggia, Nicoletta; Mäder, Karsten

    2009-01-05

    The mechanism of drug release from push-pull osmotic systems (PPOS) has been investigated by Magnetic Resonance Imaging (MRI) using a new benchtop apparatus. The signal intensity profiles of both PPOS layers were monitored non-invasively over time to characterize the hydration and swelling kinetics. The drug release performance was well-correlated to the hydration kinetics. The results show that (i) hydration and swelling critically depend on the tablet core composition, (ii) high osmotic pressure developed by the push layer may lead to bypassing the drug layer and incomplete drug release and (iii) the hydration of both the drug and the push layers needs to be properly balanced to efficiently deliver the drug. MRI is therefore a powerful tool to get insights on the drug delivery mechanism of push-pull osmotic systems, which enable a more efficient optimization of such formulations.

  8. Chaos crisis in coupled Duffing's systems with initial phase difference

    International Nuclear Information System (INIS)

    Bi Qinsheng

    2007-01-01

    The dynamics of coupled Duffing's oscillators with initial phase difference is investigated in this Letter. For the averaged equations, different equilibrium points can be observed, the number of which may vary with the parameters. The stable equilibrium points, corresponding to the periodic motion of the original coupled oscillators, may coexist with different patterns of dynamics, including chaos. Furthermore, two different chaotic attractors associated with different attracting basin coexist for certain parameter conditions, which may interact with each other to form an enlarged chaotic attractor. Several new dynamical phenomena such as boundary chaos crises have been predicted as the initial phase difference varies

  9. Brain MRI screening showing evidences of early central nervous system involvement in patients with systemic sclerosis.

    Science.gov (United States)

    Mohammed, Reem Hamdy A; Sabry, Yousriah Y; Nasef, Amr A

    2011-05-01

    Systemic sclerosis is a multisystem autoimmune collagen disease where structural and functional abnormalities of small blood vessels prevail. Transient ischemic attacks, ischemic stroke, and hemorrhage have been reported as primary consequence of vascular central nervous system affection in systemic sclerosis. Magnetic resonance imaging is considered to be the most sensitive diagnostic technique for detecting symptomatic and asymptomatic lesions in the brain in cases of multifocal diseases. The objective of this study is to detect subclinical as well as clinically manifest cerebral vasculopathy in patients with systemic sclerosis using magnetic resonance imaging. As much as 30 female patients with systemic sclerosis aged 27-61 years old, with disease duration of 1-9 years and with no history of other systemic disease or cerebrovascular accidents, were enrolled. Age-matched female control group of 30 clinically normal subjects, underwent brain magnetic resonance examination. Central nervous system (CNS) involvement in the form of white matter hyperintense foci of variable sizes were found in significantly abundant forms in systemic sclerosis patients on magnetic resonance evaluation than in age-related control group, signifying a form of CNS vasculopathy. Such foci showed significant correlation to clinical features of organic CNS lesion including headaches, fainting attacks and organic depression as well as to the severity of peripheral vascular disease with insignificant correlation with disease duration. In conclusion, subclinical as well as clinically manifest CNS ischemic vasculopathy is not uncommon in systemic sclerosis patients and magnetic resonance imaging is considered a sensitive noninvasive screening tool for early detection of CNS involvement in patients with systemic sclerosis.

  10. Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results

    Directory of Open Access Journals (Sweden)

    Mateus de Andrade Hernandes

    2012-12-01

    Full Text Available OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.

  11. Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hernandes, Mateus de Andrade; Semelka, Richard C.; Bamrungchart, Saraporn; Stallings, Clifton, E-mail: richsem@med.unc.edu [Department of Radiology, University of North Carolina, Chapel Hill, NC (United States); Elias Junior, Jorge [Imaging and Medical Physics Center, School of Medicine of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Dale, Brian M. [Siemens Medical Solutions USA, Inc., Cary, NC (United States)

    2012-11-15

    Objective: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. Materials and Methods: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. Results: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. Conclusion: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system. (author)

  12. Comparative magnetic resonance imaging of renal space-occupying lesions with a high and a low field MRI system

    International Nuclear Information System (INIS)

    Gehl, H.B.; Lorch, H.; Amblank, O.B.M.; Engerhoff, B.; Weiss, H.D.

    1998-01-01

    Purpose: A prospective study of the diagnostic accuracy and image quality of two MRI systems in the detection of renal tumors was investigated. Materials and Methods: 34 patients with the clinical suspicion of a space-occupying renal lesion were examined by MRI with a low field (0.2 Tesla magnet) and a high field (1.5 Tesla magnet) for comparison. An 'informed' and a 'blind' observer evaluated all of the MR images. In addition, the signal-to-noise and contrast-to-noise ratios were evaluated as second quality parameters. Results: In 29 cases the results could be compared with a confirmed release diagnosis. Diagnostic accuracy was comparable with both systems (Sensitivity for both observer on LF apparatus: 83%, HF apparatus: 81%) although the signal-to-noise and contrast-to-noise ratios were significantly poorer at low field. Conclusions: The low field system in comparable to the high field MRI for detection and differentiation of renal space-occupying lesions. (orig.) [de

  13. Chest MRI

    Science.gov (United States)

    ... resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI Patient Instructions ... Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology. In: Broaddus VC, Mason RJ, Ernst JD, et ...

  14. An initial bibliometric analysis and mapping of systems engineering research

    CSIR Research Space (South Africa)

    Oosthuizen, Rudolph

    2016-07-01

    Full Text Available Systems engineering is still a growing field that depends on continuous research to develop and mature. Research in systems engineering is difficult and the classic approaches for other engineering disciplines may not be sufficient. Additional...

  15. Canadian initiative leading the way for equitable health systems and ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-04-27

    Apr 27, 2016 ... Home · Resources · Publications ... The field of health systems research has grown into a vibrant community. IDRC grantees are actively involved in Health Systems Global, a newinternational agency that gathers researchers, ...

  16. 75 FR 16739 - EDA Participation in the Energy Efficient Building Systems Regional Innovation Cluster Initiative

    Science.gov (United States)

    2010-04-02

    ...: Promote regional development; Accelerate innovation, technology transfer, and entrepreneurship to create... priorities, which are: Collaborative Regional Innovation. Initiatives that support the development and growth... Participation in the Energy Efficient Building Systems Regional Innovation Cluster Initiative AGENCY: Economic...

  17. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.

    Science.gov (United States)

    Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R

    2017-11-01

    To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  18. 4 MW upgrade to DIII-D FWCD system: System commissioning and initial operation

    International Nuclear Information System (INIS)

    Cary, W.P.; Callis, R.W.; deGrassie, J.S.; Harris, T.E.; O'Neill, R.C.; Pinsker, R.I.; Baity, F.W.; Barber, G.C.; Ferguson, S.W.

    1995-01-01

    The initial installation of the 4 MW fast wave current drive (FWCD) upgrade started in 1992 with the purchase of two ABB/Thomcast AG rf power amplifiers. These amplifiers cover the frequency range 30 MHz to 120 MHz. A maximum output power of over 2 MW between 30 MHz and 80 MHz and 1 MW at 120 MHz were the specification requirements. The system as installed is comprised of the two mentioned rf amplifiers, coaxial transmission and matching components, rf phase and amplitude monitoring, and a SUN SparcStation 10 control system. Due to various reasons almost every major component in the system required redesign and engineering in order to meet the system requirements. The failures, probable cause and the final redesigns will be discussed as well as some thoughts on how better to specify system requirements for future systems

  19. 4 MW upgrade to DIII-D FWCD system: System commissioning and initial operation

    International Nuclear Information System (INIS)

    Cary, W.P.; Callis, R.W.; Grassie, J.S. de; Harris, T.E.; O'Neill, R.C.; Pinsker, R.I.; Baity, F.W.; Barber, G.C.; Ferguson, S.W.

    1995-10-01

    The initial installation of the 4 MW fast wave current drive (FWCD) upgrade started in 1992 with the purchase of two ABB/Thomcast AG rf power amplifiers. These amplifiers cover the frequency range 30 MHz to 120 MHz. A maximum output power of over 2 MW between 30 MHz and 80 MHz and 1 MW at 120 MHz were the specification requirements. The system as installed is comprised of the two mentioned rf amplifiers, coaxial transmission and matching components, rf phase and amplitude monitoring, and a SUN SparcStation 10 control system. Due to various reasons almost every major component in the system required redesign and engineering in order to meet the system requirements. The failures, probable cause and the final redesigns will be discussed as well as some thoughts on how better to specify system requirements for future systems

  20. Full-field initialized decadal predictions with the MPI earth system model: an initial shock in the North Atlantic

    Science.gov (United States)

    Kröger, Jürgen; Pohlmann, Holger; Sienz, Frank; Marotzke, Jochem; Baehr, Johanna; Köhl, Armin; Modali, Kameswarrao; Polkova, Iuliia; Stammer, Detlef; Vamborg, Freja S. E.; Müller, Wolfgang A.

    2017-12-01

    Our decadal climate prediction system, which is based on the Max-Planck-Institute Earth System Model, is initialized from a coupled assimilation run that utilizes nudging to selected state parameters from reanalyses. We apply full-field nudging in the atmosphere and either full-field or anomaly nudging in the ocean. Full fields from two different ocean reanalyses are considered. This comparison of initialization strategies focuses on the North Atlantic Subpolar Gyre (SPG) region, where the transition from anomaly to full-field nudging reveals large differences in prediction skill for sea surface temperature and ocean heat content (OHC). We show that nudging of temperature and salinity in the ocean modifies OHC and also induces changes in mass and heat transports associated with the ocean flow. In the SPG region, the assimilated OHC signal resembles well OHC from observations, regardless of using full fields or anomalies. The resulting ocean transport, on the other hand, reveals considerable differences between full-field and anomaly nudging. In all assimilation runs, ocean heat transport together with net heat exchange at the surface does not correspond to OHC tendencies, the SPG heat budget is not closed. Discrepancies in the budget in the cases of full-field nudging exceed those in the case of anomaly nudging by a factor of 2-3. The nudging-induced changes in ocean transport continue to be present in the free running hindcasts for up to 5 years, a clear expression of memory in our coupled system. In hindcast mode, on annual to inter-annual scales, ocean heat transport is the dominant driver of SPG OHC. Thus, we ascribe a significant reduction in OHC prediction skill when using full-field instead of anomaly initialization to an initialization shock resulting from the poor initialization of the ocean flow.

  1. Design and implementation of a simple multinuclear MRI system for ultra high-field imaging of animals

    Science.gov (United States)

    Choi, Chang-Hoon; Ha, YongHyun; Veeraiah, Pandichelvam; Felder, Jörg; Möllenhoff, Klaus; Shah, N. Jon

    2016-12-01

    Non-proton MRI has recently garnered gathering interest with the increased availability of ultra high-field MRI system. Assuming the availability of a broadband RF amplifier, performing multinuclear MR experiments essentially requires additional hardware, such as an RF resonator and a T/R switch for each nucleus. A double- or triple-resonant RF probe is typically constructed using traps or PIN-diode circuits, but this approach degrades the signal-to-noise ratio (SNR) and image quality compared to a single-resonant coil and this is a limiting factor. In this work, we have designed the required hardware for multinuclear MR imaging experiments employing six single-resonant coil sets and a purpose-built animal bed; these have been implemented into a home-integrated 9.4 T preclinical MRI scanner. System capabilities are demonstrated by distinguishing concentration differences and sensitivity of X-nuclei imaging and spectroscopy without SNR penalty for any nuclei, no subject interruption and no degradation of the static shim conditions.

  2. Coupled circuit numerical analysis of eddy currents in an open MRI system

    Science.gov (United States)

    Akram, Md. Shahadat Hossain; Terada, Yasuhiko; Keiichiro, Ishi; Kose, Katsumi

    2014-08-01

    We performed a new coupled circuit numerical simulation of eddy currents in an open compact magnetic resonance imaging (MRI) system. Following the coupled circuit approach, the conducting structures were divided into subdomains along the length (or width) and the thickness, and by implementing coupled circuit concepts we have simulated transient responses of eddy currents for subdomains in different locations. We implemented the Eigen matrix technique to solve the network of coupled differential equations to speed up our simulation program. On the other hand, to compute the coupling relations between the biplanar gradient coil and any other conducting structure, we implemented the solid angle form of Ampere’s law. We have also calculated the solid angle for three dimensions to compute inductive couplings in any subdomain of the conducting structures. Details of the temporal and spatial distribution of the eddy currents were then implemented in the secondary magnetic field calculation by the Biot-Savart law. In a desktop computer (Programming platform: Wolfram Mathematica 8.0®, Processor: Intel(R) Core(TM)2 Duo E7500 @ 2.93 GHz; OS: Windows 7 Professional; Memory (RAM): 4.00 GB), it took less than 3 min to simulate the entire calculation of eddy currents and fields, and approximately 6 min for X-gradient coil. The results are given in the time-space domain for both the direct and the cross-terms of the eddy current magnetic fields generated by the Z-gradient coil. We have also conducted free induction decay (FID) experiments of eddy fields using a nuclear magnetic resonance (NMR) probe to verify our simulation results. The simulation results were found to be in good agreement with the experimental results. In this study we have also conducted simulations for transient and spatial responses of secondary magnetic field induced by X-gradient coil. Our approach is fast and has much less computational complexity than the conventional electromagnetic numerical

  3. Comparative safety of gadodiamide, dimeglumine gadopentetate and meglumine gadoterate in MRI of the central nervous system

    International Nuclear Information System (INIS)

    Chanalet, S.; Bruneton, J.N.; Masson, B.; Boyer, L.; Laffont, J.

    1995-01-01

    The development of new non-ionic magnetic resonance (MR) contrast media as gadodiamide injection increased the choice of paramagnetic contrast agents available in MR of the central nervous system (CNS). The purpose of our paper was to compare at the dose of 0.1 mmol/kg b.w. the safety of gadodiamide (Gd-DTPA-BMA) to gadopentetate dimeglumine (Gd-DTPA) and to gadoterate meglumine (Gd-DOTA) in two multi centric double-blind studies. A total of 551 patients were enrolled with 143 patients in the Gd-DTPA group, 132 patients in the Gd-DOTA group and 276 patients in the Gd-DTPA-BMA group. Safety was assessed by recording the adverse events up to 24 hours after the injection. One or more adverse events were recorded in 14% of the Gd-DTPA patients, in 15.1% of the Gd-DOTA patients and in 11.6% of the Gd-DTPA-BMA patients. These reactions were related to the contrast media in 9.1%, 13.6% and 8.7% of the cases respectively. Their intensity was defined as mild in 8.4% of the patients in the Gd-DTPA group, in 13.6% of the patients in the Gd-DOTA group and in 8.3% of the patients in the Gd-DTPA-BMA group. No severe reaction or death were recorded. An injection-site reaction (heat, coldness, pain) has been observed in 43% of the cases although an adverse event other than local reactions (headache, dizziness, nausea) has been noticed in 57% of the cases. No significant statistical difference was observed between the groups. Gadodiamide is a safe and effective contrast agent in MRI of the CNS in comparison with Gd-DTPA and Gd-DOTA currently in routine use

  4. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    International Nuclear Information System (INIS)

    Staatz, G.; Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W.; Kochs, A.; Roehrig, H.

    2007-01-01

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  5. Utility of Postmortem Autopsy via Whole-Body Imaging: Initial Observations Comparing MDCT and 3.0T MRI Findings with Autopsy Findings

    International Nuclear Information System (INIS)

    Cha, Jang Gyu; Kim, Dong Hun; Paik, Sang Hyun

    2010-01-01

    We prospectively compared whole-body multidetector computed tomography (MDCT) and 3.0T magnetic resonance (MR) images with autopsy findings. Five cadavers were subjected to whole-body, 16- channel MDCT and 3.0T MR imaging within two hours before an autopsy. A radiologist classified the MDCT and 3.0T MRI findings into major and minor findings, which were compared with autopsy findings. Most of the imaging findings, pertaining to head and neck, heart and vascular, chest, abdomen, spine, and musculoskeletal lesions, corresponded to autopsy findings. The causes of death that were determined on the bases of MDCT and 3.0T MRI findings were consistent with the autopsy findings in four of five cases. CT was useful in diagnosing fatal hemorrhage and pneumothorax, as well as determining the shapes and characteristics of the fractures and the direction of external force. MRI was effective in evaluating and tracing the route of a metallic object, soft tissue lesions, chronicity of hemorrhage, and bone bruises. A postmortem MDCT combined with MRI is a potentially powerful tool, providing noninvasive and objective measurements for forensic investigations

  6. Evaluation of femoral head vascularization in slipped capital femoral epiphysis before and after cannulated screw fixation with use of contrast-enhanced MRI: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G. [Friedrich-Alexander-University Erlangen-Nuernberg, Department of Radiology, Division of Pediatric Radiology, Erlangen (Germany); University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Honnef, D.; Hohl, C.; Schmidt, T.; Guenther, R.W. [University Hospital of the RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Kochs, A.; Roehrig, H. [University Hospital of the RWTH Aachen, Department of Orthopaedic Surgery, Aachen (Germany)

    2007-01-15

    In this study we used contrast-enhanced magnetic resonance imaging (MRI) to evaluate the vascularization of the femoral head in children with slipped capital femoral epiphysis (SCFE) before and after cannulated screw fixation. Eleven consecutive children with SCFE, seven boys and four girls, aged 10-15 years were included in the study. There were no preslips; four children had acute, three acute-on-chronic, and four chronic SCFE. The MRI examinations were performed in a 1.5 Tesla MR scanner with use of a coronal STIR sequence, a coronal contrast-enhanced T1-weighted spin-echo sequence, and a sagittal three-dimensional gradient-echo sequence. Morphology, signal intensities, and contrast-enhancement of the femoral head were assessed by two radiologists in consensus. Morphologic distortion of the physis, bone marrow edema within the metaphysis and epiphysis, and joint effusion were the preoperative MRI findings of SCFE in each child. In nine children, the vascularization of the femoral head before and after surgery was normal. In one child, a preoperative avascular zone in the superolateral aspect of the epiphysis revascularized completely after surgery. One child with severe SCFE developed avascular necrosis of the femoral head after open reduction of the slip. We conclude that MRI allows for accurate evaluation of the femoral head vascularization before and after surgery in children with SCFE. (orig.)

  7. A simple classification system (the Tree flowchart) for breast MRI can reduce the number of unnecessary biopsies in MRI-only lesions

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, Ramona; Spick, Claudio; Schernthaner, Melanie; Kapetas, Panagiotis; Bernathova, Maria; Furtner, Julia; Pinker, Katja; Helbich, Thomas H.; Baltzer, Pascal A.T. [Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Clinical Institute of Pathology, Vienna (Austria)

    2017-09-15

    To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our institution for MRI-guided biopsy. All lesions were evaluated according to the Tree flowchart for breast MRI by experienced readers. The Tree flowchart is a decision rule that assigns levels of suspicion to specific combinations of diagnostic criteria. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic accuracy. To assess reproducibility by kappa statistics, a second reader rated a subset of 82 patients. There were 454 patients with 469 histopathologically verified lesions included (98 malignant, 371 benign lesions). The area under the curve (AUC) of the Tree flowchart was 0.873 (95% CI: 0.839-0.901). The inter-reader agreement was almost perfect (kappa: 0.944; 95% CI 0.889-0.998). ROC analysis revealed exclusively benign lesions if the Tree node was ≤2, potentially avoiding unnecessary biopsies in 103 cases (27.8%). Using the Tree flowchart in breast lesions only visible on MRI, more than 25% of biopsies could be avoided without missing any breast cancer. (orig.)

  8. Proven Innovations and New Initiatives in Ground System Development

    Science.gov (United States)

    Gunn, Jody M.

    2006-01-01

    The state-of-the-practice for engineering and development of Ground Systems has evolved significantly over the past half decade. Missions that challenge ground system developers with significantly reduced budgets in spite of requirements for greater and previously unimagined functionality are now the norm. Making the right trades early in the mission lifecycle is one of the key factors to minimizing ground system costs. The Mission Operations Strategic Leadership Team at the Jet Propulsion Laboratory has spent the last year collecting and working through successes and failures in ground systems for application to future missions.

  9. Effects of haloperidol and aripiprazole on the human mesolimbic motivational system: A pharmacological fMRI study.

    Science.gov (United States)

    Bolstad, Ingeborg; Andreassen, Ole A; Groote, Inge; Server, Andres; Sjaastad, Ivar; Kapur, Shitij; Jensen, Jimmy

    2015-12-01

    The atypical antipsychotic drug aripiprazole is a partial dopamine (DA) D2 receptor agonist, which differentiates it from most other antipsychotics. This study compares the brain activation characteristic produced by aripiprazole with that of haloperidol, a typical D2 receptor antagonist. Healthy participants received an acute oral dose of haloperidol, aripiprazole or placebo, and then performed an active aversive conditioning task with aversive and neutral events presented as sounds, while blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) was carried out. The fMRI task, targeting the mesolimbic motivational system that is thought to be disturbed in psychosis, was based on the conditioned avoidance response (CAR) animal model - a widely used test of therapeutic potential of antipsychotic drugs. In line with the CAR animal model, the present results show that subjects given haloperidol were not able to avoid more aversive than neutral task trials, even though the response times were shorter during aversive events. In the aripiprazole and placebo groups more aversive than neutral events were avoided. Accordingly, the task-related BOLD-fMRI response in the mesolimbic motivational system was diminished in the haloperidol group compared to the placebo group, particularly in the ventral striatum, whereas the aripiprazole group showed task-related activations intermediate of the placebo and haloperidol groups. The current results show differential effects on brain function by aripiprazole and haloperidol, probably related to altered DA transmission. This supports the use of pharmacological fMRI to study antipsychotic properties in humans. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  10. A computer-aided detection system for rheumatoid arthritis MRI data interpretation and quantification of synovial activity

    International Nuclear Information System (INIS)

    Kubassova, Olga; Boesen, Mikael; Cimmino, Marco A.; Bliddal, Henning

    2010-01-01

    Rational and objective: Disease assessment and follow-up of rheumatoid arthritis (RA) patients require objective evaluation and quantification. Magnetic resonance imaging (MRI) has a large potential to supplement such information for the clinician, however, time spent on data reading and interpretation slow down development in this area. Existing scoring systems of especially synovitis are too rigid and insensitive to measure early treatment response and quantify inflammation. This study tested a novel automated, computer system for analysis of dynamic MRI data acquired from patients with RA, Dynamika-RA, which incorporates efficient data processing and analysis techniques. Materials and methods: 140 MRI scans from hands and wrists of 135 active RA patients and 5 healthy controls were processed using Dynamika-RA and evaluated with RAMRIS. To reduce patient motion artefacts, MRI data were processed using Dynamika-RA, which removed motion in 2D and 3D planes. Then synovial enhancement was visualised and qualified using a novel fully automated voxel-by-voxel analysis based algorithm. This algorithm was used to replace traditional region-of-interest (ROI) and subtraction methods, yielding observer independent quantitative results. Results: Conventional scoring performed by an observer took 30-45 min per dataset. Dynamika-RA reduced motion artefacts, visualised inflammation and quantified disease activity in less than 3 min. Data processing allowed increasing signal to noise ratio by a factor 3. Due to fully automated procedure of data processing, there was no intertest variation in the results. Conclusions: Algorithms incorporated into Dynamika-RA allow for the significant enhancement of data quality through eliminating motion artefacts and reduction of time for evaluation of synovial inflammation.

  11. MRI of 'brain death'

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Shigeki; Itoh, Takahiko; Tuchida, Shohei; Kinugasa, Kazushi; Asari, Shoji; Nishimoto, Akira (Okayama Univ. (Japan). School of Medicine); Sanou, Kazuo

    1990-12-01

    Magnetic resonance imaging (MRI) was undertaken for two patients who suffered from severe cerebrovascular diseases and were clinically brain dead. The MRI system we used was Resona (Yokogawa Medical Systems, superconductive system 0.5 T) and the CT apparatus was Toshiba TCT-300. Initial CT and MRI were undertaken as soon as possible after admission, and repeated sequentially. After diagnosis of brain death, we performed angiography to determine cerebral circulatory arrest, and MRI obtained at the same time was compared with the angiogram and CT. Case 1 was a 77-year-old man who was admitted in an unconscious state. CT and MRI on the second day after hospitalization revealed cerebellar infarction. He was diagnosed as brain dead on day 4. Case 2 was a 35-year-old man. When he was transferred to our hospital, he was in cardiorespiratory arrested. Cardiac resuscitation was successful but no spontaneous respiration appeared. CT and MRI on admission revealed right intracerebral hemorrhage. Angiography revealed cessation of contrast medium in intracranial vessels in both of the patients. We found no 'flow signal void sign' in the bilateral internal carotid and basilar arteries on MRI images in both cases after brain death. MRI, showing us the anatomical changes of the brain, clearly revealed brain herniations, even though only nuclear findings of 'brain tamponade' were seen on CT. But in Case 1, we could not see the infarct lesions in the cerebellum on MR images obtained after brain death. This phenomenon was caused by the whole brain ischemia masking the initial ischemic lesions. We concluded that MRI was useful not only the anatomical display of lesions and brain herniation with high contrast resolution but for obtaining information on cerebral circulation of brain death. (author).

  12. National Maglev initiative: California line electric utility power system requirements

    Science.gov (United States)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  13. Cardiac tamponade as an initial manifestation of systemic lupus erythematosus.

    Science.gov (United States)

    Carrion, Diego M; Carrion, Andres F

    2012-06-12

    Clinical manifestations of pericardial disease may precede other signs and symptoms associated with systemic lupus erythematosus. Although pericardial effusion is one of the most common cardiac problems in patients with systemic lupus erythematosus, haemodynamically significant effusions manifesting as cardiac tamponade are rare and require prompt diagnosis and treatment.

  14. Estimators for initial conditions for optimisation in learning hydraulic systems

    NARCIS (Netherlands)

    Post, W.J.A.E.M.; Burrows, C.R.; Edge, K.A.

    1998-01-01

    In Learning Hydraulic Systems (LHS1. developed at the Eindhoven University of Technology, a specialised optimisation routine is employed In order to reduce energy losses in hydraulic systems. Typical load situations which can be managed by LHS are variable cyclic loads, as can be observed In many

  15. Pericarditis as initial clinical manifestation of systemic lupus ...

    African Journals Online (AJOL)

    Systemic lupus erythematosus (SLE) is a chronic, recurrent multi- systemic ... present with many years' history of nonspecific symptoms that are frequently attributed to other ... the assumed diagnoses of peptic ulcer disease, reflux oesophagitis, gastritis and ... The jugular venous pressure was not elevated. The apex beat ...

  16. Reliability analysis and initial requirements for FC systems and stacks

    Science.gov (United States)

    Åström, K.; Fontell, E.; Virtanen, S.

    In the year 2000 Wärtsilä Corporation started an R&D program to develop SOFC systems for CHP applications. The program aims to bring to the market highly efficient, clean and cost competitive fuel cell systems with rated power output in the range of 50-250 kW for distributed generation and marine applications. In the program Wärtsilä focuses on system integration and development. System reliability and availability are key issues determining the competitiveness of the SOFC technology. In Wärtsilä, methods have been implemented for analysing the system in respect to reliability and safety as well as for defining reliability requirements for system components. A fault tree representation is used as the basis for reliability prediction analysis. A dynamic simulation technique has been developed to allow for non-static properties in the fault tree logic modelling. Special emphasis has been placed on reliability analysis of the fuel cell stacks in the system. A method for assessing reliability and critical failure predictability requirements for fuel cell stacks in a system consisting of several stacks has been developed. The method is based on a qualitative model of the stack configuration where each stack can be in a functional, partially failed or critically failed state, each of the states having different failure rates and effects on the system behaviour. The main purpose of the method is to understand the effect of stack reliability, critical failure predictability and operating strategy on the system reliability and availability. An example configuration, consisting of 5 × 5 stacks (series of 5 sets of 5 parallel stacks) is analysed in respect to stack reliability requirements as a function of predictability of critical failures and Weibull shape factor of failure rate distributions.

  17. Standardization of Social Credit System Initiated in China

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Introduction The current government advances that the order of market economy should be standardized and the social credit system of market economy in modern times should be established and completed. The social credit system should be formed on the basis of property right, supported by moral and high consciousness of social credit. Therefore, the basic framework and operation mechanism of the standards system for social credit will be established in 5 years in China in order to make standards play an important role in a regular market and the aspect of credit management, to improve administration's compliance with the regulation, and to facilitate the market economic order.

  18. Controlling the Stormram 2: An MRI-compatible Robotic System for Breast Biopsy

    NARCIS (Netherlands)

    Abdelaziz, Mohamed E.M.K.; Groenhuis, Vincent; Veltman, Jeroen; Siepel, Françoise Jeanette; Stramigioli, Stefano

    2017-01-01

    Breast cancer is the most frequently life-threatening diagnosed type of cancer among women. Early and accurate diagnosis by acquiring a tissue sample using biopsy techniques is essential. However, small lesions only visible by MRI are often missed in standard methods, indicating the need for a

  19. CT and MRI in severe hypophosphataemia with central nervous system involvement

    International Nuclear Information System (INIS)

    Weber, U.; Hueppe, T.; Niehaus, L.

    2000-01-01

    We report a 38-year-old woman with extreme hypophosphataemia in whom CT and MRI disclosed bilateral lesions within the basal ganglia, thalamus and occipital lobes. After adequate substitution of phosphate the lesions grossly resolved and the patient recovered. This case is the first to demonstrate that profound changes of serum phosphate may be associated with reversible brain lesions. (orig.)

  20. Initial validations for pursuing irradiation using a gimbals tracking system

    International Nuclear Information System (INIS)

    Takayama, Kenji; Mizowaki, Takashi; Kokubo, Masaki; Kawada, Noriyuki; Nakayama, Hiroshi; Narita, Yuichiro; Nagano, Kazuo; Kamino, Yuichiro; Hiraoka, Masahiro

    2009-01-01

    Our newly designed image-guided radiotherapy (IGRT) system enables the dynamic tracking irradiation with a gimbaled X-ray head and a dual on-board kilovolt imaging subsystem for real-time target localization. Examinations using a computer-controlled three-dimensionally movable phantom demonstrated that our gimbals tracking system significantly reduced motion blurring effects in the dose distribution compared to the non-tracking state.

  1. Initial results for compressive sensing in electronic support receiver systems

    CSIR Research Space (South Africa)

    Du Plessis, WP

    2011-04-01

    Full Text Available determined by the antenna and microwave system comprising the transmitter and receiver, while the instantaneous bandwidth is mainly determined by the Analog-to-Digital Converter (ADC) in the receiver. A radar can thus operate at any frequency within its... Electronic/Electromagnetic Support Measures (ESM) was used historically [1], [2]. Modern ES receiver systems are based on digital receivers allowing powerful signal processing techniques to be used [3], [4]. Recent developments in sampling technology...

  2. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Buhmann, C. [Department of Neuroanatomy, Hannover Medical School (Germany)]|[University Hospital Eppendorf, Hamburg (Germany); Kretschmann, H.J. [Department of Neuroanatomy, Hannover Medical School (Germany)

    1998-09-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.) With 18 figs., 3 tabs., 40 refs.

  3. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    International Nuclear Information System (INIS)

    Buhmann, C.; Kretschmann, H.J.

    1998-01-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.)

  4. MRI of the Chest

    Medline Plus

    Full Text Available ... has any questions. Some implanted devices require a short period of time after placement (usually six weeks) ... center of the magnet. Some MRI units, called short-bore systems , are designed so that the magnet ...

  5. MRI of the Chest

    Medline Plus

    Full Text Available ... also provides movie-like sequential imaging of the cardiovascular system that is important to assess the health ... invaluable tool in early diagnosis and evaluation of cardiovascular conditions. MRI has proven valuable in diagnosing a ...

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... prior obstruction of blood flow). determine blood flow dynamics in the vessels and heart chambers. display lymph ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... vessels, from almost any angle. MRI also provides movie-like sequential imaging of the cardiovascular system that ... headsets so that the child can watch a movie while the scan is being performed. Thus, the ...

  8. Clinico-MRI study of hemispheric disorder in long-term follow-up cases of multiple system atrophy

    International Nuclear Information System (INIS)

    Konagaya, Masaaki; Miwa, Shigeru; Matsuoka, Yukihiko; Konagaya, Yoko

    1998-01-01

    Twelve cases of multiple system atrophy (MSA) were studied for clinical and MRI findings of the cerebral hemispheric involvement. The subjects consisted of five olivopontocerebellar atrophy (OPCA) type and seven striatonigral degeneration (SND) type. The age at onset was 56.7±8.0 (M±SD) years, duration of illness at the first MRI study 3.2±1.1 years, duration of illness at the last study 8.1±2.2 years, and the following up duration 4.9±2.0 years. The grasping phenomenon was observed in 70% of the cases examined, snout reflex in 80%, slowness of verbal response in 88%, and decrease of spontaneous speech in 100%. Three cases finally fell into the state of mutism. Three out of ten cases were categorized as dementia by HDS-R (Hasegawa Dementia Scale-Revised) test. Besides the progression of the pontocerebellar atrophy and putaminal changes, MRI study revealed progressive frontal lobe atrophy in most cases. At six years after the onset, SND type showed significantly higher incidence of conspicuous frontal lobe atrophy and dilatation of the Sylvian fissure than OPCA type. Cerebral ventricular dilatation was common feature, and atrophy of the temporal and occipital lobes were observed in several cases. We indicated the possible involvement of the cerebral hemisphere, especially the frontal lobe, and higher nervous function in MSA. (author)

  9. Clinico-MRI study of hemispheric disorder in long-term follow-up cases of multiple system atrophy

    Energy Technology Data Exchange (ETDEWEB)

    Konagaya, Masaaki; Miwa, Shigeru; Matsuoka, Yukihiko [Suzuka National Hospital, Mie (Japan); Konagaya, Yoko

    1998-12-01

    Twelve cases of multiple system atrophy (MSA) were studied for clinical and MRI findings of the cerebral hemispheric involvement. The subjects consisted of five olivopontocerebellar atrophy (OPCA) type and seven striatonigral degeneration (SND) type. The age at onset was 56.7{+-}8.0 (M{+-}SD) years, duration of illness at the first MRI study 3.2{+-}1.1 years, duration of illness at the last study 8.1{+-}2.2 years, and the following up duration 4.9{+-}2.0 years. The grasping phenomenon was observed in 70% of the cases examined, snout reflex in 80%, slowness of verbal response in 88%, and decrease of spontaneous speech in 100%. Three cases finally fell into the state of mutism. Three out of ten cases were categorized as dementia by HDS-R (Hasegawa Dementia Scale-Revised) test. Besides the progression of the pontocerebellar atrophy and putaminal changes, MRI study revealed progressive frontal lobe atrophy in most cases. At six years after the onset, SND type showed significantly higher incidence of conspicuous frontal lobe atrophy and dilatation of the Sylvian fissure than OPCA type. Cerebral ventricular dilatation was common feature, and atrophy of the temporal and occipital lobes were observed in several cases. We indicated the possible involvement of the cerebral hemisphere, especially the frontal lobe, and higher nervous function in MSA. (author)

  10. Influence of changes in initial conditions for the simulation of dynamic systems

    Energy Technology Data Exchange (ETDEWEB)

    Kotyrba, Martin [Department of Informatics and Computers, University of Ostrava, 30 dubna 22, Ostrava (Czech Republic)

    2015-03-10

    Chaos theory is a field of study in mathematics, with applications in several disciplines including meteorology, sociology, physics, engineering, economics, biology, and philosophy. Chaos theory studies the behavior of dynamical systems that are highly sensitive to initial conditions—a paradigm popularly referred to as the butterfly effect. Small differences in initial conditions field widely diverging outcomes for such dynamical systems, rendering long-term prediction impossible in general. This happens even though these systems are deterministic, meaning that their future behavior is fully determined by their initial conditions, with no random elements involved. In this paperinfluence of changes in initial conditions will be presented for the simulation of Lorenz system.

  11. Evaluation of the incidence of nephrogenic systemic fibrosis in patients with moderate renal insufficiency administered gadobenate dimeglumine for MRI

    International Nuclear Information System (INIS)

    Bryant, B.J.; Im, K.; Broome, D.R.

    2009-01-01

    Aim: To determine the incidence of nephrogenic systemic fibrosis (NSF) in stage 3 chronic kidney disease patients following intravenous exposure to gadobenate dimeglumine. Materials and methods: A prospective study was performed on 168 consecutive patients at a single institution with stage 3 chronic kidney disease who underwent clinically-indicated contrast-enhanced magnetic resonance imaging (MRI) examinations with gadobenate dimeglumine from January 2007 to March 2008. All patients were contacted by phone by investigators 3 months after MRI to verify the presence or absence of NSF signs or symptoms. If signs or symptoms suggestive of NSF developed, dermatologic referral was made and confirmatory skin biopsy performed if indicated. Results: One hundred and eighty contrast-enhanced MRI examinations with gadobenate dimeglumine were performed on the 168 patients. Twenty patients were lost to follow-up, but 160 incidents of contrast medium exposure were followed up for 3-months and 105 incidents were followed up for 6 months. The mean contrast medium dose per weight was 0.093 mmol/kg (range 0.042-0.153 mmol/kg). The mean estimated creatinine clearance was 50.4 ml/min/1.73 m 2 (range from 30-59 ml/min/1.73 m 2 ). Ten patients developed skin rashes during the 3-month follow-up period, but none were confirmed to represent NSF (0% prevalence rate). No other signs or symptoms of NSF were reported. Conclusion: Based on this limited study, NSF does not appear to occur in patients with stage 3 chronic kidney disease exposed to intravenous gadobenate dimeglumine for MRI at standard dosing of ∼0.1 mmol/kg.

  12. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  13. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Science.gov (United States)

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling... for public comment draft regulatory guide (DG), DG-1277, ``Initial Test Program of Emergency Core..., entitled, ``Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors,'' is...

  14. SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Duke University Medical Physics Program (United States); Yin, F; Czito, B; Bashir, M; Palta, M; Cai, J [Duke University Medical Center, Durham, NC (United States); Zhong, X; Dale, B [Siemens Healthcare, Durham, NC (United States)

    2015-06-15

    Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15

  15. Anaesthesia for MRI: ….child's play?

    African Journals Online (AJOL)

    Adele

    radiology as well as in the operating room. MRI offers superior soft-tissue contrast and can create images through any body plane. The success of an MRI ... MRI then became a practical real- ity with the ... Magnetic field strengths in MRI systems range from 0. 15-3. 0 tesla. ... Time varied magnetic field interference. Magnetic ...

  16. Initial evaluation of a full breast digital system

    International Nuclear Information System (INIS)

    Vano, E.; Fernandez, J.M.; Chevalier, M.; Moran, P.; Cepeda, T.; Fabra, A.; Alvarez Pedrosa, C.S.

    2001-01-01

    Full-field digital mammography systems have been developed for overcoming the limitations of the screen-film mammography. This work is focused on the system from GE Medical Systems (Senographe 2000) which has been recently installed in our institution. The imager consists of a thin Ics:Tl scintillator which is in narrow contact with an array of amorphous silicon detectors mounted in a single panel. The flat-panel detector is integrated in a x-ray system with a high-frequency generator Senographe DM and dual track anode of Mo and Rh with Mo and Rh filtration. The aim of this work is to analyse the defaults exposure factors set at the installation of the x-ray unit. The image quality has been evaluated by using one of the two phantoms recommended in the ACR Accreditation Program. Phantom images were obtained at each of the three available imaging modes: contrast (CNT), standard (STD) and DOSE. While maintaining the defaults of kilovoltage and anode/filter combination, phantom images were obtained at lower dose vales. The contrast noise ratio (CNR) was calculated for each of the low contrast objects (masses) of the phantom images and the detail visibility was also evaluated. The results obtained for both parameters reveal that similar image quality can be obtained with significant reductions of the average glandular dose. (author)

  17. Two patients with osteoporosis : initial presentation of systemic mastocytosis

    NARCIS (Netherlands)

    Donker, Marjolein L.; Bakker, Nicolaas A.; Jaspers, Wim J. M.; Verhage, Albert H.

    In two patients with osteoporosis, systemic mastocytosis ultimately turned out to be the underlying disease. Both patients had a history of anaphylactic reactions caused by wasp stings but did not have any skin or other symptoms. This observation reflects the need for careful history taking and

  18. Initial development of an automated task analysis profiling system

    International Nuclear Information System (INIS)

    Jorgensen, C.C.

    1984-01-01

    A program for automated task analysis is described. Called TAPS (task analysis profiling system), the program accepts normal English prose and outputs skills, knowledges, attitudes, and abilities (SKAAs) along with specific guidance and recommended ability measurement tests for nuclear power plant operators. A new method for defining SKAAs is presented along with a sample program output

  19. Transforming Energy Systems and Indian Initiatives in Intelligent Grid

    Science.gov (United States)

    Razdan, Anil

    2014-07-01

    Ancient words of wisdom have remarkable clarity, brevity, universality and timelessness in their applicability. They cut across civilizations, systems, and situations, almost effortlessly. The positive take is that mistakes can be committed, but can be rectified. What may be appropriate in one situation, has to change in another context. Two proverbs from diverse civilizations are very relevant in the current context...

  20. The Battle Command Sustainment Support System: Initial Analysis Report

    Science.gov (United States)

    2016-09-01

    products including jet fuels, distillate fuels, residual fuels, automotive gasoline , specified bulk lubricating oils, aircraft engine oils, fuel...contained within this report. 15. SUBJECT TERMS Mission command Software Tactical applications (TacApps) Command post ...computing environment (CPCE) Command post client Battle command sustainment support System (BCS3) Logistics

  1. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  2. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  3. Longitudinal study of sodium MRI of articular cartilage in patients with knee osteoarthritis: initial experience with 16-month follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Madelin, Guillaume; Xia, Ding; Brown, Ryan; Babb, James; Chang, Gregory; Regatte, Ravinder R. [New York University School of Medicine, Department of Radiology, Center for Biomedical Imaging, New York, NY (United States); Krasnokutsky, Svetlana [New York University School of Medicine, Department of Medicine, Rheumatology Division, New York, NY (United States)

    2018-01-15

    To evaluate the potential of sodium MRI to detect changes over time of apparent sodium concentration (ASC) in articular cartilage in patients with knee osteoarthritis (OA). The cartilage of 12 patients with knee OA were scanned twice over a period of approximately 16 months with two sodium MRI sequences at 7 T: without fluid suppression (radial 3D) and with fluid suppression by adiabatic inversion recovery (IR). Changes between baseline and follow-up of mean and standard deviation of ASC (in mM), and their rate of change (in mM/day), were measured in the patellar, femorotibial medial and lateral cartilage regions for each subject. A matched-pair Wilcoxon signed rank test was used to assess significance of the changes. Changes in mean and in standard deviation of ASC, and in their respective rate of change over time, were only statistically different when data was acquired with the fluid-suppressed sequence. A significant decrease (p = 0.001) of approximately 70 mM in mean ASC was measured between the two IR scans. Quantitative sodium MRI with fluid suppression by adiabatic IR at 7 T has the potential to detect a decrease of ASC over time in articular cartilage of patients with knee osteoarthritis. (orig.)

  4. Longitudinal study of sodium MRI of articular cartilage in patients with knee osteoarthritis: initial experience with 16-month follow-up

    International Nuclear Information System (INIS)

    Madelin, Guillaume; Xia, Ding; Brown, Ryan; Babb, James; Chang, Gregory; Regatte, Ravinder R.; Krasnokutsky, Svetlana

    2018-01-01

    To evaluate the potential of sodium MRI to detect changes over time of apparent sodium concentration (ASC) in articular cartilage in patients with knee osteoarthritis (OA). The cartilage of 12 patients with knee OA were scanned twice over a period of approximately 16 months with two sodium MRI sequences at 7 T: without fluid suppression (radial 3D) and with fluid suppression by adiabatic inversion recovery (IR). Changes between baseline and follow-up of mean and standard deviation of ASC (in mM), and their rate of change (in mM/day), were measured in the patellar, femorotibial medial and lateral cartilage regions for each subject. A matched-pair Wilcoxon signed rank test was used to assess significance of the changes. Changes in mean and in standard deviation of ASC, and in their respective rate of change over time, were only statistically different when data was acquired with the fluid-suppressed sequence. A significant decrease (p = 0.001) of approximately 70 mM in mean ASC was measured between the two IR scans. Quantitative sodium MRI with fluid suppression by adiabatic IR at 7 T has the potential to detect a decrease of ASC over time in articular cartilage of patients with knee osteoarthritis. (orig.)

  5. Longitudinal sensitivity to change of MRI-based muscle cross-sectional area versus isometric strength analysis in osteoarthritic knees with and without structural progression: pilot data from the Osteoarthritis Initiative.

    Science.gov (United States)

    Dannhauer, Torben; Sattler, Martina; Wirth, Wolfgang; Hunter, David J; Kwoh, C Kent; Eckstein, Felix

    2014-08-01

    Biomechanical measurement of muscle strength represents established technology in evaluating limb function. Yet, analysis of longitudinal change suffers from relatively large between-measurement variability. Here, we determine the sensitivity to change of magnetic resonance imaging (MRI)-based measurement of thigh muscle anatomical cross sectional areas (ACSAs) versus isometric strength in limbs with and without structural progressive knee osteoarthritis (KOA), with focus on the quadriceps. Of 625 "Osteoarthritis Initiative" participants with radiographic KOA, 20 had MRI cartilage and radiographic joint space width loss in the right knee isometric muscle strength measurement and axial T1-weighted spin-echo acquisitions of the thigh. Muscle ACSAs were determined from manual segmentation at 33% femoral length (distal to proximal). In progressor knees, the reduction in quadriceps ACSA between baseline and 2-year follow-up was -2.8 ± 7.9 % (standardized response mean [SRM] = -0.35), and it was -1.8 ± 6.8% (SRM = -0.26) in matched, non-progressive KOA controls. The decline in extensor strength was more variable than that in ACSAs, both in progressors (-3.9 ± 20%; SRM = -0.20) and in non-progressive controls (-4.5 ± 28%; SRM = -0.16). MRI-based analysis of quadriceps muscles ACSAs appears to be more sensitive to longitudinal change than isometric extensor strength and is suggestive of greater loss in limbs with structurally progressive KOA than in non-progressive controls.

  6. Toward an MRI-based method to measure non-uniform cartilage deformation: an MRI-cyclic loading apparatus system and steady-state cyclic displacement of articular cartilage under compressive loading.

    Science.gov (United States)

    Neu, C P; Hull, M L

    2003-04-01

    Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the cartilage in both the underformed and deformed states. The objectives of the work reported in this article were to 1) design an apparatus that could apply highly repeatable cyclic compressive loads of 400 N and operate in the bore of an MRI scanner, 2) demonstrate that the apparatus and MRI scanner can be successfully integrated to observe 3D deformations in a phantom material, 3) use the apparatus to determine the load cycle necessary to achieve a steady-state deformation response in normal bovine articular cartilage samples using a flat-surfaced and nonporous indentor in unconfined compression. Composed of electronic and pneumatic components, the apparatus regulated pressure to a double-acting pneumatic cylinder so that (1) load-controlled compression cycles were applied to cartilage samples immersed in a saline bath, (2) loading and recovery periods within a cycle varied in time duration, and (3) load magnitude varied so that the stress applied to cartilage samples was within typical physiological ranges. In addition the apparatus allowed gating for MR image acquisition, and operation within the bore of an MRI scanner without creating image artifacts. The apparatus demonstrated high repeatability in load application with a standard deviation of 1.8% of the mean 400 N load applied. When the apparatus was integrated with an MRI scanner programmed with appropriate pulse sequences, images of a phantom material in both the underformed and deformed states were constructed by assembling data acquired through multiple signal acquisitions. Additionally, the number of cycles to reach

  7. Social-ecological system framework: initial changes and continuing challenges

    Directory of Open Access Journals (Sweden)

    Michael D. McGinnis

    2014-06-01

    Full Text Available The social-ecological system (SES framework investigated in this special issue enables researchers from diverse disciplinary backgrounds working on different resource sectors in disparate geographic areas, biophysical conditions, and temporal domains to share a common vocabulary for the construction and testing of alternative theories and models that determine which influences on processes and outcomes are especially critical in specific empirical settings. We summarize changes that have been made to this framework and discuss a few remaining ambiguities in its formulation. Specifically, we offer a tentative rearrangement of the list of relevant attributes of governance systems and discuss other ways to make this framework applicable to policy settings beyond natural resource settings. The SES framework will continue to change as more researchers apply it to additional contexts; the main purpose of this article is to delineate the version that served as the basis for the theoretical innovations and empirical analyses detailed in other contributions to this special issue.

  8. ROI Analysis of the System Architecture Virtual Integration Initiative

    Science.gov (United States)

    2018-04-01

    errors that are detected during testing. The percentages reflect the lower defect- leakage rates of 2.5% into operation for safety-critical systems...Introduced and Detected Defects 16 Table 7: Defect-Removal Cost, Given the Phase of Origin 16 Table 8: Nominal Phase-Based Rework Costs and Percentages...show that detecting and removing defects are the most expensive and time-consuming parts of the work. Finding and fixing defects alone often causes

  9. {sup 18}F-FDG PET/MRI in patients suffering from lymphoma: how much MRI information is really needed?

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, Julian; Heusch, Philipp; Antoch, Gerald [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Deuschl, Cornelius; Grueneisen, Johannes; Forsting, Michael; Umutlu, Lale [University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Herrmann, Ken [University of Duisburg-Essen, Department of Nuclear Medicine, University Hospital Essen, Essen (Germany)

    2017-06-15

    To evaluate and compare the diagnostic potential of different reading protocols, entailing non-enhanced/contrast-enhanced and diffusion-weighted {sup 18}F-FDG PET/MR imaging for lesion detection and determination of the tumor stage in lymphoma patients. A total of 101 {sup 18}F-FDG PET/MRI datasets including a (1) transverse T2-w HASTE and {sup 18}F-FDG PET (PET/MRI{sub 1}), (2) with an additional contrast enhanced VIBE (PET/MRI{sub 2}), and (3) with additional diffusion-weighted imaging (PET/MRI{sub 3}) were evaluated. Scans were performed for initial staging, restaging during treatment, or at the end of treatment and under surveillance with suspicion for tumor relapse. In all datasets lymphoma manifestations as well as tumor stage in analogy to the revised criteria of the Ann Arbor staging system were determined. Furthermore, potential changes in therapy compared to the reference standard were evaluated. Hitherto performed PET/CT and all available follow-up and prior examinations as well as histopathology served as reference standard. PET/MRI{sub 1} correctly identified 53/55 patients with active lymphoma and 190/205 lesions. Respective values were 55/55, 202/205 for PET/MRI{sub 2} and 55/55, 205/205 for PET/MRI{sub 3}. PET/MRI{sub 1} determined correct tumor stage in 88 out of 101 examinations, and corresponding results for PET/MRI{sub 2} were 95 out of 101 and 96 out of 101 in PET/MRI{sub 3}. Relating to the reference standard changes in treatment would occur in 11% based on PET/MRI{sub 1}, in 6% based on PET/MRI{sub 2}, and in 3% based on PET/MRI{sub 3}. The additional application of contrast-enhanced and diffusion-weighted imaging to {sup 18}F-FDG PET/MRI resulted in higher diagnostic competence, particularly for initial staging and correct classification of the disease extent with potential impact on patient and therapy management. (orig.)

  10. Real-time image reconstruction and display system for MRI using a high-speed personal computer.

    Science.gov (United States)

    Haishi, T; Kose, K

    1998-09-01

    A real-time NMR image reconstruction and display system was developed using a high-speed personal computer and optimized for the 32-bit multitasking Microsoft Windows 95 operating system. The system was operated at various CPU clock frequencies by changing the motherboard clock frequency and the processor/bus frequency ratio. When the Pentium CPU was used at the 200 MHz clock frequency, the reconstruction time for one 128 x 128 pixel image was 48 ms and that for the image display on the enlarged 256 x 256 pixel window was about 8 ms. NMR imaging experiments were performed with three fast imaging sequences (FLASH, multishot EPI, and one-shot EPI) to demonstrate the ability of the real-time system. It was concluded that in most cases, high-speed PC would be the best choice for the image reconstruction and display system for real-time MRI. Copyright 1998 Academic Press.

  11. Initial evaluation of a femtosecond laser system in cataract surgery.

    Science.gov (United States)

    Chang, John S M; Chen, Ivan N; Chan, Wai-Man; Ng, Jack C M; Chan, Vincent K C; Law, Antony K P

    2014-01-01

    To report the early experience and complications during cataract surgery with a noncontact femtosecond laser system. Hong Kong Sanatorium and Hospital, Hong Kong Special Administrative Region, China. Retrospective case series. All patients had anterior capsulotomy or combined anterior capsulotomy and lens fragmentation using a noncontact femtosecond laser system (Lensar) before phacoemulsification. Chart and video reviews were performed retrospectively to determine the intraoperative complication rate. Risk factors associated with the complications were also analyzed. One hundred seventy eyes were included. Free-floating capsule buttons were found in 151 eyes (88.8%). No suction break occurred in any case. Radial anterior capsule tears occurred in 9 eyes (5.3%); they did not extend to the equator or posterior capsule. One eye (0.6%) had a posterior capsule tear. No capsular block syndrome developed, and no nuclei were dropped during irrigation/aspiration (I/A). Anterior capsule tags and miosis occurred in 4 eyes (2.4%) and 17 eyes (10.0%), respectively. Different severities of subconjunctival hemorrhages developed in 71 (43.8%) of 162 eyes after the laser procedure. The mean surgical time from the beginning to the end of suction was 6.72 minutes ± 4.57 (SD) (range 2 to 28 minutes). Cataract surgery with the noncontact femtosecond laser system was safe. No eye lost vision because of complications. Caution should be taken during phacoemulsification and I/A to avoid radial anterior capsule tears and posterior capsule tears. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. [ZHU Lian's New Acupuncture Academic System and acupuncture science initialization].

    Science.gov (United States)

    Zhang, Shujian; Zhang, Lijian

    2015-11-01

    Acupuncture scientization was a consensus of most of acupuncture scholars who had long-term perspectives in the 20th century, among them Ms. ZHULian was the important one. Ms. ZHU Lian built a systemic new acupuncture" academic structure in practice and theory aspects. At the same time, as the main architect of Institute of Acupuncture-moxibustion of China Academy of Traditional Chinese Medicine, Ms. ZHU Lian was the first one who began to carry out the acupuncture clinical trail and laboratory experiment in modern way, which meant "acupuncture therapy" was transformed into "acupuncture science" by Ms. ZHULian's endeavor.

  13. Central nervous system infectious diseases mimicking multiple sclerosis: recognizing distinguishable features using MRI

    Directory of Open Access Journals (Sweden)

    Antonio Jose da Rocha

    2013-09-01

    Full Text Available The current diagnostic criteria for multiple sclerosis (MS confirm the relevant role of magnetic resonance imaging (MRI, supporting the possibility of characterizing the dissemination in space (DIS and the dissemination in time (DIT in a single scan. To maintain the specificity of these criteria, it is necessary to determine whether T2/FLAIR visible lesions and the gadolinium enhancement can be attributed to diseases that mimic MS. Several diseases are included in the MS differential diagnosis list, including diseases with exacerbation, remitting periods and numerous treatable infectious diseases, which can mimic the MRI features of MS. We discuss the most relevant imaging features in several infectious diseases that resemble MS and examine the primary spatial distributions of lesions and the gadolinium enhancement patterns related to MS. Recognizing imaging "red flags" can be useful for the proper diagnostic evaluation of suspected cases of MS, facilitating the correct differential diagnosis by assessing the combined clinical, laboratory and MR imaging information.

  14. Magnet dislocation: an increasing and serious complication following MRI in patients with cochlear implants.

    Science.gov (United States)

    Hassepass, F; Stabenau, V; Arndt, S; Beck, R; Bulla, S; Grauvogel, T; Aschendorff, A

    2014-07-01

    Cochlear implantation (CI) represents the gold standard in the treatment of children born deaf and postlingually deafened adults. Initial magnetic resonance imaging (MRI) was contraindicated in CI users. Meanwhile, there are specific recommendations concerning MRI compatibility depending on the type of CI system and the device manufacturer. Some CI systems are even approved for MRI with the internal magnet left in place. The aim of this study was to analyze all magnet revision surgeries in CI patients at one CI center and the relationship to MRI scans over time. Between 2000 and 2013, a total of 2027 CIs were implanted. The number of magnet dislocation (MD) surgeries and their causes was assessed retrospectively. In total 12 cases of MD resulting from an MRI scan (0.59 %) were observed, accounting for 52.2 % of all magnetic revision surgeries. As per the labeling, it was considered safe to leave the internal magnet in place during MRI while following specific manufacturer recommendations: MRI intensity of 1.5 Tesla (T) and compression head bandage during examination. A compression head bandage in a 1.5 T MRI unit does not safely prevent MD and the related serious complications in CI recipients. We recommend a Stenvers view radiograph after MRI with the internal magnet in place for early identification of MD, at least in the case of pain during or after MRI examination. MRI in CI patients should be indicated with restraint and patients should be explicitly informed about the possible risks. Recommendations regarding MRI compatibility and the handling of CI patients issued with MRI for the most common CI systems are summarized. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Policies and initiatives for carbon neutrality in nordic heating and transport systems

    DEFF Research Database (Denmark)

    Muller, Jakob Glarbo; Wu, Qiuwei; Ostergaard, Jacob

    2012-01-01

    Policies and initiatives promoting carbon neutrality in the Nordic heating and transport systems are presented. The focus within heating systems is the propagation of heat pumps while the focus within transport systems is initiatives regarding electric vehicles (EVs). It is found that conversion...... to heat pumps in the Nordic region rely on both private economic and national economic incentives. Initiatives toward carbon neutrality in the transport system are mostly concentrated on research, development and demonstration for deployment of a large number of EVs. All Nordic countries have plans...... for the future heating and transport systems with the ambition of realizing carbon neutrality....

  16. 75 FR 17700 - Energy Efficient Building Systems Regional Innovation Cluster Initiative-Joint Federal Funding...

    Science.gov (United States)

    2010-04-07

    ... economically dynamic regional innovation cluster focused on energy efficient buildings technologies and systems...-risk, high-reward research that overcomes technology challenges through approaches that span basic... DEPARTMENT OF ENERGY Energy Efficient Building Systems Regional Innovation Cluster Initiative...

  17. Development of an MRI-Guided Intra-Prostatic Needle Placement System

    Science.gov (United States)

    2011-07-01

    Worcester Polytechnic Institute. Downloaded on August 09,2010 at 01:03:56 UTC from IEEE Xplore . Restrictions apply. Fig. 5. This mechanis provides for...Authorized licensed use limited to: Worcester Polytechnic Institute. Downloaded on August 09,2010 at 01:03:56 UTC from IEEE Xplore . Restrictions apply...A, Su H, Approaches to Creating and Controlling Motion in MRI, In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in

  18. Initial Assessment of Cyclone Global Navigation Satellite System (CYGNSS) Observations

    Science.gov (United States)

    McKague, D. S.; Ruf, C. S.

    2017-12-01

    The NASA Cyclone Global Navigation Satellite System (CYNSS) mission provides high temporal resolution observations of cyclones from a constellation of eight low-Earth orbiting satellites. Using the relatively new technique of Global Navigation Satellite System reflectometry (GNSS-R), all-weather observations are possible, penetrating even deep convection within hurricane eye walls. The compact nature of the GNSS-R receivers permits the use of small satellites, which in turn enables the launch of a constellation of satellites from a single launch vehicle. Launched in December of 2016, the eight CYGNSS satellites provide 25 km resolution observations of mean square slope (surface roughness) and surface winds with a 2.8 hour median revisit time from 38 S to 38 N degrees latitude. In addition to the calibration and validation of CYGNSS sea state observations, the CYGNSS science team is assessing the ability of the mission to provide estimates of cyclone size, intensity, and integrated kinetic energy. With its all-weather ability and high temporal resolution, the CYGNSS mission will add significantly to our ability to monitor cyclone genesis and intensification and will significantly reduce uncertainties in our ability to estimate cyclone intensity, a key variable in predicting its destructive potential. Members of the CYGNSS Science Team are also assessing the assimilation of CYGNSS data into hurricane forecast models to determine the impact of the data on forecast skill, using the data to study extra-tropical cyclones, and looking at connections between tropical cyclones and global scale weather, including the global hydrologic cycle. This presentation will focus on the assessment of early on-orbit observations of cyclones with respect to these various applications.

  19. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  20. Initial commissioning results from the APS loss monitor system

    International Nuclear Information System (INIS)

    Patterson, D.R.

    1996-01-01

    The design of the beam loss monitor system for the Argonne National Laboratory Advanced Photon Source is based on using a number of air dielectric coaxial cables as long ionization chambers. Results to date show that the loss monitor is useful in helping to determine the cause of injection losses and losses large enough to limit circulating currents in the storage ring to short lifetimes. Sensitivities ranging from 13 to 240 pC of charge collected in the injector BTS (booster-to-storage-ring) loss monitor per picocoulomb of loss have been measured, depending on the loss location. These results have been used to predict that the storage ring loss monitor leakage current limit of 10 pA per cable should allow detection of losses resulting in beam lifetimes of 100 hours or less with 100 mA stored beam. Significant DC bias levels associated with the presence of stored beam have been observed. These large bias levels are most likely caused by the loss monitor responding to hard x-ray synchrotron radiation. No such response to synchrotron radiation was observed during earlier tests at SSRL. However, the loss monitor response to average stored beam current in APS has provided a reasonable alternative to the DC current transformer (DCCT) for measuring beam lifetimes

  1. Association of pharmacokinetic and metabolic parameters derived using simultaneous PET/MRI: Initial findings and impact on response evaluation in breast cancer.

    Science.gov (United States)

    Jena, Amarnath; Taneja, Sangeeta; Singh, Aru; Negi, Pradeep; Mehta, Shashi Bhushan; Ahuja, Aashim; Singhal, Manish; Sarin, Ramesh

    2017-07-01

    To study relationships among pharmacokinetic and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET parameters obtained through simultaneous PET/MRI in breast cancer patients and evaluate their combined potential for response evaluation. The study included 41 breast cancer patients for correlation study and 9 patients (pre and post therapy) for response evaluation. All patients underwent simultaneous PET/MRI with dedicated breast imaging. Pharmacokinetic parameters and PET parameters for tumor were derived using an in- house developed and vendor provided softwares respectively. Relationships between SUV and pharmacokinetic parameters and clinical as well as histopathologic parameters were evaluated using Spearman correlation analysis. Response to chemotherapy was derived as percentage reduction in size and in parameters post therapy. Significant correlations were observed between SUVmean, max, peak, TLG with K trans (ρ=0.446, 0.417, 0.491, 0.430; p≤0.01); with Kep(ρ=0.303, ρ=0.315, ρ=0.319; p≤0.05); and with iAUC(ρ=0.401, ρ=0.410, ρ=0.379; p≤0.05, p≤0.01). The ratio of ve/iAUC showed significant negative correlation to SUVmean, max, peak and TLG (ρ=0.420, 0.446, 0.443, 0.426; p≤0.01). Ability of SUV as well as pharmacokinetic parameters to predict response to therapy matched the RECIST criteria in 9 out of 11 lesions in 9 patients. Maximum post therapy quantitative reduction was observed in SUVpeak, TLG and K trans . Simultaneous PET/MRI enables illustration of close interactions between glucose metabolism and pharmacokinetic parameters in breast cancer patients and potential of their simultaneity in response assessment to therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Multi-modal MRI analysis with disease-specific spatial filtering: initial testing to predict mild cognitive impairment patients who convert to Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Kenichi eOishi

    2011-08-01

    Full Text Available Background: Alterations of the gray and white matter have been identified in Alzheimer’s disease (AD by structural MRI and diffusion tensor imaging (DTI. However, whether the combination of these modalities could increase the diagnostic performance is unknown.Methods: Participants included 19 AD patients, 22 amnestic mild cognitive impairment (aMCI patients, and 22 cognitively normal elderly (NC. The aMCI group was further divided into an aMCI-converter group (converted to AD dementia within three years, and an aMCI-stable group who did not convert in this time period. A T1-weighted image, a T2 map, and a DTI of each participant were normalized, and voxel-based comparisons between AD and NC groups were performed. Regions-of-interest, which defined the areas with significant differences between AD and NC, were created for each modality and named disease-specific spatial filters (DSF. Linear discriminant analysis was used to optimize the combination of multiple MRI measurements extracted by DSF to effectively differentiate AD from NC. The resultant DSF and the discriminant function were applied to the aMCI group to investigate the power to differentiate the aMCI-converters from the aMCI-stable patients. Results: The multi-modal approach with AD-specific filters led to a predictive model with an area under the receiver operating characteristic curve (AUC of 0.93, in differentiating aMCI-converters from aMCI-stable patients. This AUC was better than that of a single-contrast-based approach, such as T1-based morphometry or diffusion anisotropy analysis. Conclusion: The multi-modal approach has the potential to increase the value of MRI in predicting conversion from aMCI to AD.

  3. Novel use of non-echo-planar diffusion weighted MRI in monitoring disease activity and treatment response in active Grave's orbitopathy: An initial observational cohort study.

    Science.gov (United States)

    Lingam, Ravi Kumar; Mundada, Pravin; Lee, Vickie

    2018-01-10

    To examine the novel use of non-echo-planar diffusion weighted MRI (DWI) in depicting activity and treatment response in active Grave's orbitopathy (GO) by assessing, with inter-observer agreement, for a correlation between its apparent diffusion coefficients (ADCs) and conventional Short tau Inversion Recovery (STIR) MRI signal-intensity ratios (SIRs). A total of 23 actively inflamed muscles and 30 muscle response episodes were analysed in patients with active GO who underwent medical treatment. The MRI orbit scans included STIR sequences and non-echo-planar DWI were evaluated. Two observers independently assessed the images qualitatively for the presence of activity in the extraocular muscles (EOMs) and recorded the STIR signal-intensity (SI), SIR (SI ratio of EOM/temporalis muscle), and ADC values of any actively inflamed muscle on the pre-treatment scans and their corresponding values on the subsequent post-treatment scans. Inter-observer agreement was examined. There was a significant positive correlation (0.57, p < 0.001) between ADC and both SIR and STIR SI of the actively inflamed EOM. There was also a significant positive correlation (0.75, p < 0.001) between SIR and ADC values depicting change in muscle activity associated with treatment response. There was good inter-observer agreement. Our preliminary results indicate that quantitative evaluation with non-echo-planar DWI ADC values correlates well with conventional STIR SIR in detecting active GO and monitoring its treatment response, with good inter-observer agreement.

  4. Value of 18F-FDG PET/MRI for the outcome of CT-guided facet block therapy in cervical facet syndrome: initial results

    International Nuclear Information System (INIS)

    Sawixki, Lino M.; Schaarscjmidt, Benedikt M.; Heusch, Philipp; Buchbender, Christian; Antoch, Gerald; Rosenbaum-Krumme, Sandra; Bockisch, Andreas; Umutlu, Lale; Eicker, Sven O.; Floeth, Frank W.

    2017-01-01

    The aim of this study was to evaluate the ability of 18 F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ( 18 F-FDG PET/MRI) to detect PET-positive cervical facet arthropathy and identify patients who benefit from facet block therapy. Ten patients with cervical facet syndrome (mean age: 65 ± 12 years) underwent 18 F-FDG PET/MRI of the neck. Focal 18 F-FDG uptake in PET-positive facet joints served as target for computed tomography (CT)-guided facet blocks. In PET-negative patients, the target joint for facet block therapy was selected by current clinical standards considering the level of maximum facet arthrosis and pain. Neck pain was measured on visual analogue scale (VAS) before and after therapy. Bone marrow signal intensity (SI) ratio on turbo inversion recovery magnitude (TIRM) images and maximum standard uptake values (SUVmax) was calculated for each facet joint. Pearson's correlation coefficient (r) was calculated between bone marrow SI ratios on TIRM and SUVmax. 18 F-FDG PET/MRI detected PET-positive facet arthropathy in six patients. Patients with PET-positive facet arthropathy had significantly less pain compared with the pretreatment pain 3 h (P = 0.002), 4 weeks (P = 0.002) and 3 months (P = 0.026) after facet block therapy. Pain did not change significantly in patients with PET-negative facet arthropathy. TIRM SI ratio was higher in PET-positive facet arthropathy than in PET-negative facet arthropathy (P < 0.001). Correlation was strong between bone marrow SI ratio on TIRM images and SUVmax (r = 0.7; P < 0.001).

  5. Energy Efficiency Building Systems Regional Innovation Cluster Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Krebs, Martha [Pennsylvania State Univ., University Park, PA (United States)

    2016-07-29

    The Consortium for Building Energy Innovation (CBEI) was established through a Funding Opportunity Announcement led by the U.S. Department of Energy, under a cooperative agreement managed by the National Energy Technology Laboratory. CBEI is led by The Pennsylvania State University and is composed of partners from academia, the private sector, and economic development agencies. The Consortium has included as many as 24 different partners over the five years, but 14 have been core to the work over the five year cooperative agreement. CBEI primarily focused on developing energy efficiency solutions for the small and medium commercial building market, with a focus on buildings less than 50,000 square feet. This market has been underserved by the energy efficiency industry, which has focused on larger commercial buildings where the scale of an individual retrofit lends itself to the use of sophisticated modeling tools and more advanced solutions. Owners/operators and retrofit providers for larger buildings have a greater level of understanding of, and experience with different solutions. In contrast, smaller commercial building retrofits, like residential retrofits, often have owners with less knowledge about energy management and less time to learn about it. This market segment is also served by retrofit providers that are smaller and often focused on particular building systems, e.g. heating, ventilation and air conditioning (HVAC), lighting, roofing, or insulation. The size of a smaller commercial building retrofit does not lend itself, from a cost perspective, to the application of multiple, sophisticated design and modeling tools, which means that they are less likely to have integrated solutions.

  6. Masked assessment of MRI findings: is it possible to differentiate neuro-Behcet`s disease from other central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Coban, O.; Bahar, S.; Akman-Demir, G.; Tasci, B.; Serdaroglu, P. [Univ. of Istanbul (Turkey). Dept. of Neurology; Yurdakul, S.; Yazici, H. [Univ. of Istanbul (Turkey). Dept. of Internal Medicine

    1999-04-01

    Two neuroradiologists reviewed MRI studies of 34 patients with neuro-Behcet`s disease (NBD), 22 with multiple sclerosis (MS) and 7 with systemic lupus erythematosus (SLE) with central nervous system involvement, masked to the clinical diagnosis, age and sex of the patients. Of the patients with NBD 12 were in an acute attack; the others had chronic disease. MRI was assessed using a set of criteria, looking at atrophy, the site of discrete parenchymal lesions, regions of predominant involvement and the extent of the lesion(s). The observers also made a guess at the clinical diagnosis. The brain stem and/or basal ganglia were the most predominantly involved sites in all patients with acute NBD; 75 % of these lesions were large and confluent, mainly extending from the brain stem to the diencephalon and basal ganglia. However, in chronic cases, the predominant involvement was in the brain stem and/or basal ganglia in only 36 %, and in cerebral hemisphere white matter in another 36 %; 27 % of these patients showed no parenchymal lesion. Hemisphere white-matter lesions were equally distributed between periventricular and other areas in NBD, while in MS more were periventricular, and in SLE more were nonperiventricular. Brain-stem atrophy was seen in 21 % of patients with NBD, with a specificity of 96.5 %. In the absence of cortical atrophy, its specificity was 100 %. The attempt at making a radiological diagnosis was successful in all cases of acute NBD and 95.5 % of patients with MS, but in only 40 % of patients with chronic NBD. Most of this latter groups MRI studies were interpreted as MS. An extensive lesion involving the brain stem and basal ganglia seemed to be diagnostic of acute NBD. However, hemisphere white-matter lesions could not be differentiated from those in MS. (orig.) With 3 figs., 6 tabs., 18 refs.

  7. Initial in vitro and in vivo assessment of Au@DTDTPA-RGD nanoparticles for Gd-MRI and 68Ga-PET dual modality imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukalas, Charalmpos [National Center for Scientific Research ' Demokritos' (Greece); Laurent, Gautier; Jiménez Sánchez, Gloria [Université de Franche-Comté, Institut UTINAM (France); Tsotakos, Theodoros [National Center for Scientific Research ' Demokritos' (Greece); Bazzi, Rana [Université de Franche-Comté, Institut UTINAM (France); Stellas, Dimitris; Anagnostopoulos, Constantinos [Biomedical Research Foundation, Academy of Athens (Greece); Moulopoulos, Lia; Koutoulidis, Vasilis [Department of Radiology, Areteion Hospital, University of Athens Medical School (Greece); Paravatou-Petsotas, Maria; Xanthopoulos, Stavros [National Center for Scientific Research ' Demokritos' (Greece); Roux, Stephane [Université de Franche-Comté, Institut UTINAM (France); Bouziotis, Penelope [National Center for