WorldWideScience

Sample records for mri optical topography

  1. Functional Topography of Human Corpus Callosum: An fMRI Mapping Study

    OpenAIRE

    Fabri, Mara; Polonara, Gabriele

    2013-01-01

    The concept of a topographical map of the corpus callosum (CC) has emerged from human lesion studies and from electrophysiological and anatomical tracing investigations in other mammals. Over the last few years a rising number of researchers have been reporting functional magnetic resonance imaging (fMRI) activation in white matter, particularly the CC. In this study the scope for describing CC topography with fMRI was explored by evoking activation through simple sensory stimulation and moto...

  2. Brain function measurement using optical topography

    International Nuclear Information System (INIS)

    Koizumi, Hideaki; Maki, Atsushi; Yamamoto, Tsuyoshi; Kawaguchi, Hideo

    2003-01-01

    Optical topography is a completely non-invasive method to image the high brain function with the near infrared spectroscopy, does not need the restriction of human behavior for imaging and thereby is applicable even for infants. The principle is based on irradiation of the near infrared laser beam with the optical-fiber onto the head surface and detection with the fiber of the reflection, of which spectroscopy for blood-borne hemoglobin gives the local cerebral homodynamics related with the nerve activity. The infrared laser beam of 1-10 mW is found safe on direct irradiation to the human body. The topography is applicable in the fields of clinical medicine like internal neurology (an actual image of the activated Broca's and Welnicke's areas at writing is presented), neurosurgery, psychiatry and pedriatric neurology, of developmental cognitive neuroscience, of educational science and of communication. ''MIT Technology Reviews'' mentions that this technique is one of 4 recent promising innovative techniques in the world. (N.I.)

  3. Signal filtering algorithm for depth-selective diffuse optical topography

    International Nuclear Information System (INIS)

    Fujii, M; Nakayama, K

    2009-01-01

    A compact filtered backprojection algorithm that suppresses the undesirable effects of skin circulation for near-infrared diffuse optical topography is proposed. Our approach centers around a depth-selective filtering algorithm that uses an inverse problem technique and extracts target signals from observation data contaminated by noise from a shallow region. The filtering algorithm is reduced to a compact matrix and is therefore easily incorporated into a real-time system. To demonstrate the validity of this method, we developed a demonstration prototype for depth-selective diffuse optical topography and performed both computer simulations and phantom experiments. The results show that the proposed method significantly suppresses the noise from the shallow region with a minimal degradation of the target signal.

  4. MRI findings and correlative study of MRI and visual evoked potentials in optic neuritis

    International Nuclear Information System (INIS)

    Yan Fei; Li Jing; Wang Zhenchang; Liu Shoubin; Zhang Xiaojun

    2008-01-01

    Objective: To investigate the effective MRI sequences and describe the correlation between MRI and visual evoked potential (VEP) in diagnosing optic neuritis. Methods: One hundred and fifty-four eyes with visual impairment of 98 patients with diagnoses of optic neuritis, papillitis, multiple sclerosis and Devic's disease underwent MRI and VEP examination. The MRI findings were analyzed and correlated with VEP results and clinical presentation by using X 2 test, wilco xon test and Kappa test. Results Out of the 154 sick eyes, 56 eyes presented thickened optic nerves, 76 eyes had normal diameter of the optic nerve, and 22 eyes had thin optic nerves. A total of 132 optic nerves showed abnormally high signal in STIR sequences, including involvement of intraocular segment in 7, intraorbital segment in 1.35, intracanalicular segment in 109, intracranial segment in 97, optic chiasm in 56, and optic tract in 23. A total of 54 patients underwent postcontrast MRI. Seventy-four optic nerves of 87 eyes showed enhancement. Among the 196 eyes of 98 patients, 132 eyes presented visual impairment and simultaneous abnormal MR signal of the optic nerve, and 26 eyes had both normal vision and normal MR signal of optic nerve. The consistency of MRI findings and vision status was 80. 61% (Kappa 0.453,P 1 -weighted MR sequence combined with fat- suppression are helpful in diagnosis of optic neuritis. VEP is helpful in diagnosing optic neuritis and in finding subclinical visual problem. The MRI combined with VEP could improve the diagnostic accuracy of optic neuritis. (authors)

  5. Determination of the transfer function for optical surface topography measuring instruments—a review

    International Nuclear Information System (INIS)

    Foreman, Matthew R; Török, Peter; Giusca, Claudiu L; Leach, Richard K; Coupland, Jeremy M

    2013-01-01

    A significant number of areal surface topography measuring instruments, largely based on optical techniques, are commercially available. However, implementation of optical instrumentation into production is currently difficult due to the lack of understanding of the complex interaction between the light and the component surface. Studying the optical transfer function of the instrument can help address this issue. Here a review is given of techniques for the measurement of optical transfer functions. Starting from the basis of a spatially coherent, monochromatic confocal scanning imaging system, the theory of optical transfer functions in three-dimensional (3D) imaging is presented. Further generalizations are reviewed allowing the extension of the theory to the description of conventional and interferometric 3D imaging systems. Polychromatic transfer functions and surface topography measurements are also discussed. Following presentation of theoretical results, experimental methods to measure the optical transfer function of each class of system are presented, with a focus on suitable methods for the establishment of calibration standards in 3D imaging and surface topography measurements. (topical review)

  6. The role of surface topography in predicting scattering at grazing incidence from optical surfaces

    International Nuclear Information System (INIS)

    Rehn, V.; Jones, V.O.; Elson, J.M.; Bennett, J.M.

    1980-01-01

    Monochromator design and the design of optical experiments at XUV and X-ray wavelengths are frequently limited by scattering from optical components, yet theoretical treatments are few and untested experimentally. This is partly due to the failure of scattering models used in the visible and near UV when the wavelength becomes comparable to, or smaller than, the topographic features on the surface, and partly it is due to the difficulty in measuring the topography on the required size scale. We briefly review the theoretical problems and prospects for accurately predicting both the magnitude and angular distribution of scattering at grazing incidence from optical surfaces. Experimental methods for determining and representing the surface topography are also reviewed, together with their limitations and ranges of applicability. Finally, the first results of our experiments, conducted recently at the Stanford Synchrotron Radiation Laboratory on the angular distribution of scattering by surfaces of known topography are presented and discussed, along with their potential implications for the theory of scattering, and for XUV and X-ray optical components. (orig.)

  7. An fMRI Study of Intra-Individual Functional Topography in the Human Cerebellum

    Directory of Open Access Journals (Sweden)

    Catherine J. Stoodley

    2010-01-01

    Full Text Available Neuroimaging studies report cerebellar activation during both motor and non-motor paradigms, and suggest a functional topography within the cerebellum. Sensorimotor tasks activate the anterior lobe, parts of lobule VI, and lobule VIII, whereas higher-level tasks activate lobules VI and VII in the posterior lobe. To determine whether these activation patterns are evident at a single-subject level, we conducted functional magnetic resonance imaging (fMRI during five tasks investigating sensorimotor (finger tapping, language (verb generation, spatial (mental rotation, working memory (N-back, and emotional processing (viewing images from the International Affective Picture System. Finger tapping activated the ipsilateral anterior lobe (lobules IV-V as well as lobules VI and VIII. Activation during verb generation was found in right lobules VII and VIIIA. Mental rotation activated left-lateralized clusters in lobules VII-VIIIA, VI-Crus I, and midline VIIAt. The N-back task showed bilateral activation in right lobules VI-Crus I and left lobules VIIB-VIIIA. Cerebellar activation was evident bilaterally in lobule VI while viewing arousing vs. neutral images. This fMRI study provides the first proof of principle demonstration that there is topographic organization of motor execution vs. cognitive/emotional domains within the cerebellum of a single individual, likely reflecting the anatomical specificity of cerebro-cerebellar circuits underlying different task domains. Inter-subject variability of motor and non-motor topography remains to be determined.

  8. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes.

    Science.gov (United States)

    Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S

    2013-11-01

    To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  9. The application of confocal technology based on polycapillary X-ray optics in surface topography

    International Nuclear Information System (INIS)

    Zhao, Guangcui; Sun, Tianxi; Liu, Zhiguo; Yuan, Hao; Li, Yude; Liu, Hehe; Zhao, Weigang; Zhang, Ruixia; Min, Qin; Peng, Song

    2013-01-01

    A confocal micro-X-ray fluorescence (MXRF) technology based on polycapillary X-ray optics was proposed for determining surface topography. This confocal topography method involves elemental sensitivity and can be used to classify the objects according to their elemental composition while obtaining their surface topography. To improve the spatial resolution of this confocal topography technology, the center of the confocal micro-volume was overlapped with the output focal spot of the polycapillary X-ray, focusing the lens in the excitation channel. The input focal spot of the X-ray lens parallel to the detection channel was used to determine the surface position of the sample. The corresponding surface adaptive algorithm was designed to obtain the surface topography. The surface topography of a ceramic chip was obtained. This confocal MXRF surface topography method could find application in the materials sciences

  10. Sounds and silence: An optical topography study of language recognition at birth

    Science.gov (United States)

    Peña, Marcela; Maki, Atsushi; Kovaic, Damir; Dehaene-Lambertz, Ghislaine; Koizumi, Hideaki; Bouquet, Furio; Mehler, Jacques

    2003-09-01

    Does the neonate's brain have left hemisphere (LH) dominance for speech? Twelve full-term neonates participated in an optical topography study designed to assess whether the neonate brain responds specifically to linguistic stimuli. Participants were tested with normal infant-directed speech, with the same utterances played in reverse and without auditory stimulation. We used a 24-channel optical topography device to assess changes in the concentration of total hemoglobin in response to auditory stimulation in 12 areas of the right hemisphere and 12 areas of the LH. We found that LH temporal areas showed significantly more activation when infants were exposed to normal speech than to backward speech or silence. We conclude that neonates are born with an LH superiority to process specific properties of speech.

  11. Topography description of thin films by optical Fourier Transform

    International Nuclear Information System (INIS)

    Jaglarz, Janusz

    2008-01-01

    In this work, the main problems concerning the scattering of light by real surfaces and films are presented in view of results obtained with the bidirectional reflection distribution function (BRDF) method and optical profilometry (OP). The BRDF and OP studies, being complementary to the atomic force microscopy (AFM), allow one to get information about surface topography. From the optical data, the surface power spectral density (PSD) functions for absorbing and transparent rough films have been found. Both functions have been evaluated from the Fourier transform (FT) of the surface profiles. The usefulness of BRDF-and OP methods in characterization of real surfaces is demonstrated when analyzing the optical data obtained for metallic TiN-and organic PVK thin films deposited on various substrates

  12. Topography description of thin films by optical Fourier Transform

    Energy Technology Data Exchange (ETDEWEB)

    Jaglarz, Janusz [Institute of Physics, Cracow University of Technology, ul. Podchoraz.ych 1, 30-084 Krakow (Poland)], E-mail: pujaglar@cyfronet.krakow.pl

    2008-09-30

    In this work, the main problems concerning the scattering of light by real surfaces and films are presented in view of results obtained with the bidirectional reflection distribution function (BRDF) method and optical profilometry (OP). The BRDF and OP studies, being complementary to the atomic force microscopy (AFM), allow one to get information about surface topography. From the optical data, the surface power spectral density (PSD) functions for absorbing and transparent rough films have been found. Both functions have been evaluated from the Fourier transform (FT) of the surface profiles. The usefulness of BRDF-and OP methods in characterization of real surfaces is demonstrated when analyzing the optical data obtained for metallic TiN-and organic PVK thin films deposited on various substrates.

  13. Diffusion-weighted MRI in acute posterior ischemic optic neuropathy

    International Nuclear Information System (INIS)

    Srinivasan, Sivasubramanian; Moorthy, Srikant; Sreekumar, KP; Kulkarni, Chinmay

    2012-01-01

    Blindness following surgery, especially cardiac surgery, has been reported sporadically, the most common cause being ischemic optic neuropathy. The role of MRI in the diagnosis of this condition is not well established. We present a case of postoperative posterior ischemic optic neuropathy that was diagnosed on diffusion-weighted MRI

  14. Optical properties and surface topography of CdCl2 activated CdTe thin films

    Science.gov (United States)

    Patel, S. L.; Purohit, A.; Chander, S.; Dhaka, M. S.

    2018-05-01

    The effect of post-CdCl2 heat treatment on optical properties and surface topography of evaporated CdTe thin films is investigated. The pristine and thermally annealed films were subjected to UV-Vis spectrophotometer and atomic force microscopy (AFM) to investigate the optical properties and surface topography, respectively. The absorbance is found to be maximum (˜90%) at 320°C temperature and transmittance found to be minimum and almost constant in ultraviolet and visible regions. The direct band gap is increased from 1.42 eV to 2.12 eV with post-CdCl2 annealing temperature. The surface topography revealed that the uniformity is improved with annealing temperature and average surface roughness is found in the range of 83.3-144.3 nm as well as grains have cylindrical hill-like shapes. The investigated results indicate that the post-CdCl2 treated films annealed at 320°C may be well-suitable for thin film solar cells as an absorber layer.

  15. Primary Sjoegren's syndrome initially manifested by optic neuritis: MRI findings

    International Nuclear Information System (INIS)

    Kadota, Y.; Tokumaru, A.M.; Kohyama, S.; Okizuka, H.; Kaji, T.; Kusano, S.; Kamakura, K.

    2002-01-01

    We herein describe the MRI findings in a patient clinically diagnosed with primary Sjoegren's syndrome (SjS) initially manifested by retrobulbar optic neuritis. A 63-year-old woman suddenly had left ocular pain and progressive visual disturbance. MR T2-weighted images revealed hyperintensity in the left optic nerve, with swelling. Contrast-enhanced T1-weighted images showed no abnormal enhancement. Follow-up MRI 6 months after admission revealed no significant changes in the affected optic nerve. To our knowledge, optic neuritis as a complication of SjS has been reported in ten patients [1, 2, 3, 4, 5, 6] and MRI findings in only one of them [6]. We thought MR images were useful for visualizing optic nerve involvement in SjS and observing its course. (orig.)

  16. Triaxial fiber optic magnetic field sensor for MRI applications

    Science.gov (United States)

    Filograno, Massimo L.; Pisco, Marco; Catalano, Angelo; Forte, Ernesto; Aiello, Marco; Soricelli, Andrea; Davino, Daniele; Visone, Ciro; Cutolo, Antonello; Cusano, Andrea

    2016-05-01

    In this paper, we report a fiber-optic triaxial magnetic field sensor, based on Fiber Bragg Gratings (FBGs) integrated with giant magnetostrictive material, the Terfenol-D. The realized sensor has been designed and engineered for Magnetic Resonance Imaging (MRI) applications. A full magneto-optical characterization of the triaxial sensing probe has been carried out, providing the complex relationship among the FBGs wavelength shift and the applied magnetostatic field vector. Finally, the developed fiber optic sensors have been arranged in a sensor network composed of 20 triaxial sensors for mapping the magnetic field distribution in a MRI-room at a diagnostic center in Naples (SDN), equipped with Positron emission tomography/magnetic resonance (PET/MR) instrumentation. Experimental results reveal that the proposed sensor network can be efficiently used in MRI centers for performing quality assurance tests, paving the way for novel integrated tools to measure the magnetic dose accumulated day by day by MRI operators.

  17. Incidence and Outcomes of Optical Zone Enlargement and Recentration After Previous Myopic LASIK by Topography-Guided Custom Ablation.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara

    2018-02-01

    To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after

  18. MRI of the optic nerve in benign intracranial hypertension

    International Nuclear Information System (INIS)

    Gass, A.; Barker, G.J.; Riordan-Eva, P.; MacManus, D.; Sanders, M.; Tofts, P.S.; McDonald, W.I.; Moseley, I.F.; Miller, D.H.

    1996-01-01

    We investigated the MRI appearance of the optic nerve and its cerebrospinal-fluid-containing sheath in 17 patients with benign intracranial hypertension (BIH) and 15 normal controls. Using phased-array local coils, 3-mm coronal T2-weighted fat-suppressed fast spin-echo images were obtained with an in-plane resolution of < 0.39 mm. The optic nerve and its sheath were clearly differentiated. An enlarged, elongated subarachnoid space around the optic nerve was demonstrated in patients with BIH. High-resolution MRI of the optic nerve offers additional information which may be of value for diagnosis and in planning and monitoring treatment. (orig.). With 5 figs

  19. Topography. Ch. 10

    International Nuclear Information System (INIS)

    Chikawa, Jun-Ichi; Kuriyama, Masao

    1991-01-01

    The uniqueness of synchrotron X-ray topography does not lie in new theoretical or experimental notions about the topographic method, but in the characteristics of this new source as a critical optical element. At most synchrotron facilities, the spectrum ranging from 5 keV (2.5A) to 30 keV (0.4A0 can be made available for topography. A synchrotron-radiation source gives tunability (choice of wavelengths) and pulsed time structure with highly collimated an intense photon beams. The continuous spectrum and excellent collimation have made white-beam X-ray topography a practical reality. The high intensity of the synchrotron X-ray source, even after beam monochromatization and further collimation, permits time-dependent observation of kinetics. By selecting the mono-chromatized wavelength close to an absorption edge of an element in the sample crystal, the topographic data selectively emphasize or de-emphasize structures related to that element. For full use of such properties of synchrotron radiation, however, development of new optical systems and imaging detectors is required, and is in progress at most synchrotron facilities. This chapter covers a brief review of X-ray topography, its basic principles, and the necessary X-ray optical and imaging systems. The capability of synchrotron-radiation topography is demonstrated with some recent results. (author). 118 refs.; 22 figs

  20. Metrological characterization methods for confocal chromatic line sensors and optical topography sensors

    Science.gov (United States)

    Seppä, Jeremias; Niemelä, Karri; Lassila, Antti

    2018-05-01

    The increasing use of chromatic confocal technology for, e.g. fast, in-line optical topography, and measuring thickness, roughness and profiles implies a need for the characterization of various aspects of the sensors. Single-point, line and matrix versions of chromatic confocal technology, encoding depth information into wavelength, have been developed. Of these, line sensors are particularly suitable for in-line process measurement. Metrological characterization and development of practical methods for calibration and checking is needed for new optical methods and devices. Compared to, e.g. tactile methods, optical topography measurement techniques have limitations related to light wavelength and coherence, optical properties of the sample including reflectivity, specularity, roughness and colour, and definition of optical versus mechanical surfaces. In this work, metrological characterization methods for optical line sensors were developed for scale magnification and linearity, sensitivity to sample properties, and dynamic characteristics. An accurate depth scale calibration method using a single prototype groove depth sample was developed for a line sensor and validated with laser-interferometric sample tracking, attaining (sub)micrometre level or better than 0.1% scale accuracy. Furthermore, the effect of different surfaces and materials on the measurement and depth scale was studied, in particular slope angle, specularity and colour. In addition, dynamic performance, noise, lateral scale and resolution were measured using the developed methods. In the case of the LCI1200 sensor used in this study, which has a 11.3 mm  ×  2.8 mm measurement range, the instrument depth scale was found to depend only minimally on sample colour, whereas measuring steeply sloped specular surfaces in the peripheral measurement area, in the worst case, caused a somewhat larger relative sample-dependent change (1%) in scale.

  1. Optic nerve injury demonstrated by MRI with STIR sequences

    International Nuclear Information System (INIS)

    Takehara, S.; Tanaka, T.; Uemura, K.; Shinohara, Y.; Yamamoto, T.; Tokuyama, T.; Satoh, A.

    1994-01-01

    We studied nine patients with optic nerve injury associated with closed head trauma by magnetic resonance imaging (MRI) with short inversion time inversion recovery (STIR) sequences on 11 occasions from 4 days to 14 years after the injury: three studies were within 17 days and eight over 4 months to 14 years. MRI revealed abnormal high signal in 10 of the 11 injured nerves. MRI 4 days after the injury showed no abnormality. (orig.)

  2. Magnetic resonance imaging (MRI) in the diagnosis of optic neuritis and neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kojima, Shigeyuki; Hirayama, Keizo

    1989-02-01

    Magnetic resonance imaging (MRI) was performed in thirty patients who had been suffering from optic neuritis (ON). Twenty-one cases were caused by multiple sclerosis (MS) and in 9 cases the causes been defined. In MRI, abnormalities were found in 17 out of 21 MS cases in several places such as near the ventricles, mid-brain, spinal cord etc. Increased signals from the optic chiasm to optic radiation were found in 5 cases. However, abnormal MRI findings did not always correspond to Goldmann visual field defects. In 3 out of 9 cases of ON with unknown causes, high signals in the white matter of the brain were found, and it was suggested that those may develop to MS. MRI was, thus, proved to be very useful for the diagnois of MS.

  3. Magnetic resonance imaging (MRI) in the diagnosis of optic neuritis and neuropathy

    International Nuclear Information System (INIS)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) was performed in thirty patients who had been suffering from optic neuritis (ON). Twenty-one cases were caused by multiple sclerosis (MS) and in 9 cases the causes been defined. In MRI, abnormalities were found in 17 out of 21 MS cases in several places such as near the ventricles, mid-brain, spinal cord etc. Increased signals from the optic chiasm to optic radiation were found in 5 cases. However, abnormal MRI findings did not always correspond to Goldmann visual field defects. In 3 out of 9 cases of ON with unknown causes, high signals in the white matter of the brain were found, and it was suggested that those may develop to MS. MRI was, thus, proved to be very useful for the diagnois of MS. (author)

  4. Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review

    Science.gov (United States)

    Iordachita, Iulian I.; Tokuda, Junichi; Hata, Nobuhiko; Liu, Xuan; Seifabadi, Reza; Xu, Sheng; Wood, Bradford; Fischer, Gregory S.

    2017-01-01

    Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures. PMID:28652857

  5. Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review.

    Science.gov (United States)

    Su, Hao; Iordachita, Iulian I; Tokuda, Junichi; Hata, Nobuhiko; Liu, Xuan; Seifabadi, Reza; Xu, Sheng; Wood, Bradford; Fischer, Gregory S

    2017-04-01

    Magnetic Resonance Imaging (MRI) provides both anatomical imaging with excellent soft tissue contrast and functional MRI imaging (fMRI) of physiological parameters. The last two decades have witnessed the manifestation of increased interest in MRI-guided minimally invasive intervention procedures and fMRI for rehabilitation and neuroscience research. Accompanying the aspiration to utilize MRI to provide imaging feedback during interventions and brain activity for neuroscience study, there is an accumulated effort to utilize force sensors compatible with the MRI environment to meet the growing demand of these procedures, with the goal of enhanced interventional safety and accuracy, improved efficacy and rehabilitation outcome. This paper summarizes the fundamental principles, the state of the art development and challenges of fiber optic force sensors for MRI-guided interventions and rehabilitation. It provides an overview of MRI-compatible fiber optic force sensors based on different sensing principles, including light intensity modulation, wavelength modulation, and phase modulation. Extensive design prototypes are reviewed to illustrate the detailed implementation of these principles. Advantages and disadvantages of the sensor designs are compared and analyzed. A perspective on the future development of fiber optic sensors is also presented which may have additional broad clinical applications. Future surgical interventions or rehabilitation will rely on intelligent force sensors to provide situational awareness to augment or complement human perception in these procedures.

  6. Spatial Topography of Individual-Specific Cortical Networks Predicts Human Cognition, Personality, and Emotion.

    Science.gov (United States)

    Kong, Ru; Li, Jingwei; Orban, Csaba; Sabuncu, Mert R; Liu, Hesheng; Schaefer, Alexander; Sun, Nanbo; Zuo, Xi-Nian; Holmes, Avram J; Eickhoff, Simon B; Yeo, B T Thomas

    2018-06-06

    Resting-state functional magnetic resonance imaging (rs-fMRI) offers the opportunity to delineate individual-specific brain networks. A major question is whether individual-specific network topography (i.e., location and spatial arrangement) is behaviorally relevant. Here, we propose a multi-session hierarchical Bayesian model (MS-HBM) for estimating individual-specific cortical networks and investigate whether individual-specific network topography can predict human behavior. The multiple layers of the MS-HBM explicitly differentiate intra-subject (within-subject) from inter-subject (between-subject) network variability. By ignoring intra-subject variability, previous network mappings might confuse intra-subject variability for inter-subject differences. Compared with other approaches, MS-HBM parcellations generalized better to new rs-fMRI and task-fMRI data from the same subjects. More specifically, MS-HBM parcellations estimated from a single rs-fMRI session (10 min) showed comparable generalizability as parcellations estimated by 2 state-of-the-art methods using 5 sessions (50 min). We also showed that behavioral phenotypes across cognition, personality, and emotion could be predicted by individual-specific network topography with modest accuracy, comparable to previous reports predicting phenotypes based on connectivity strength. Network topography estimated by MS-HBM was more effective for behavioral prediction than network size, as well as network topography estimated by other parcellation approaches. Thus, similar to connectivity strength, individual-specific network topography might also serve as a fingerprint of human behavior.

  7. Spike voltage topography in temporal lobe epilepsy.

    Science.gov (United States)

    Asadi-Pooya, Ali A; Asadollahi, Marjan; Shimamoto, Shoichi; Lorenzo, Matthew; Sperling, Michael R

    2016-07-15

    We investigated the voltage topography of interictal spikes in patients with temporal lobe epilepsy (TLE) to see whether topography was related to etiology for TLE. Adults with TLE, who had epilepsy surgery for drug-resistant seizures from 2011 until 2014 at Jefferson Comprehensive Epilepsy Center were selected. Two groups of patients were studied: patients with mesial temporal sclerosis (MTS) on MRI and those with other MRI findings. The voltage topography maps of the interictal spikes at the peak were created using BESA software. We classified the interictal spikes as polar, basal, lateral, or others. Thirty-four patients were studied, from which the characteristics of 340 spikes were investigated. The most common type of spike orientation was others (186 spikes; 54.7%), followed by lateral (146; 42.9%), polar (5; 1.5%), and basal (3; 0.9%). Characteristics of the voltage topography maps of the spikes between the two groups of patients were somewhat different. Five spikes in patients with MTS had polar orientation, but none of the spikes in patients with other MRI findings had polar orientation (odds ratio=6.98, 95% confidence interval=0.38 to 127.38; p=0.07). Scalp topographic mapping of interictal spikes has the potential to offer different information than visual inspection alone. The present results do not allow an immediate clinical application of our findings; however, detecting a polar spike in a patient with TLE may increase the possibility of mesial temporal sclerosis as the underlying etiology. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Shvyd’ko, Yuri; Trakhtenberg, Emil; Liu, Zunping; Lang, Keenan; Huang, Xianrong; Wieczorek, Michael; Kasman, Elina; Hammonds, John; Macrander, Albert; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

  9. The effects of wallerian degeneration of the optic radiations demonstrated by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Savoiardo, M.; Grisoli, M.; Forester, M.; D' Incerti, L.; Farina, L. (Dept. of Neuroradiology, Ist. Nazionale Neurologico C. Besta, Milan (Italy)); Pareyson, D. (Dept. of Neurology, Ist. Nazionale Neurologico C. Besta, Milan (Italy))

    1992-08-01

    The effects of wallerian degeneration can be demonstrated by MRI as abnormal signal along the course of the degenerate fibres; they have previously been reported in the corticospinal tract. We report two cases of wallerian degeneration of the right optic radiations due to lesions of the right lateral geniculate body. The anatomy and the MRI visibility of the normal optic radiations are briefly discussed. (orig.).

  10. The effects of wallerian degeneration of the optic radiations demonstrated by MRI

    International Nuclear Information System (INIS)

    Savoiardo, M.; Grisoli, M.; Forester, M.; D'Incerti, L.; Farina, L.; Pareyson, D.

    1992-01-01

    The effects of wallerian degeneration can be demonstrated by MRI as abnormal signal along the course of the degenerate fibres; they have previously been reported in the corticospinal tract. We report two cases of wallerian degeneration of the right optic radiations due to lesions of the right lateral geniculate body. The anatomy and the MRI visibility of the normal optic radiations are briefly discussed. (orig.)

  11. Simultaneous topography and tomography of latent fingerprints using full-field swept-source optical coherence tomography

    Science.gov (United States)

    Dubey, Satish Kumar; Singh Mehta, Dalip; Anand, Arun; Shakher, Chandra

    2008-01-01

    We demonstrate simultaneous topography and tomography of latent fingerprints using full-field swept-source optical coherence tomography (OCT). The swept-source OCT system comprises a superluminescent diode (SLD) as broad-band light source, an acousto-optic tunable filter (AOTF) as frequency tuning device, and a compact, nearly common-path interferometer. Both the amplitude and the phase map of the interference fringe signal are reconstructed. Optical sectioning of the latent fingerprint sample is obtained by selective Fourier filtering and the topography is retrieved from the phase map. Interferometry, selective filtering, low coherence and hence better resolution are some of the advantages of the proposed system over the conventional fingerprint detection techniques. The present technique is non-invasive in nature and does not require any physical or chemical processing. Therefore, the quality of the sample does not alter and hence the same fingerprint can be used for other types of forensic test. Exploitation of low-coherence interferometry for fingerprint detection itself provides an edge over other existing techniques as fingerprints can even be lifted from low-reflecting surfaces. The proposed system is very economical and compact.

  12. Early bilateral radiation-induced optic neuropathy with follow-up MRI

    International Nuclear Information System (INIS)

    McClellan, R.L.; El Gammal, T.; Kline, L.B.

    1995-01-01

    Most documented cases of radiation-induced optic neuropathy are unilateral and occur more than 1 year after radiotherapy to the sellar region. We describe a patient with bilateral radiation optic neuropathy 3 months following the completion of radiotherapy. MRI 13 months after the onset of visual failure showed bilateral optic atrophy with residual gadolinium enhancement. (orig.)

  13. Early bilateral radiation-induced optic neuropathy with follow-up MRI

    Energy Technology Data Exchange (ETDEWEB)

    McClellan, R.L. [Alabama Univ., Birmingham (United States). Dept. of Radiology; El Gammal, T. [Alabama Univ., Birmingham (United States). Dept. of Radiology; Kline, L.B. [Alabama Univ., Birmingham (United States). Dept. of Radiology

    1995-02-01

    Most documented cases of radiation-induced optic neuropathy are unilateral and occur more than 1 year after radiotherapy to the sellar region. We describe a patient with bilateral radiation optic neuropathy 3 months following the completion of radiotherapy. MRI 13 months after the onset of visual failure showed bilateral optic atrophy with residual gadolinium enhancement. (orig.)

  14. Development of an Optical Fiber-Based MR Compatible Gamma Camera for SPECT/MRI Systems

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Tadashi; Kanai, Yasukazu; Watabe, Hiroshi; Hatazawa, Jun

    2015-02-01

    Optical fiber is a promising material for integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) PET/MRI systems. Because its material is plastic, it has no interference between MRI. However, it is unclear whether this material can also be used for a single photon emission tomography (SPECT)/MRI system. For this purpose, we developed an optical fiber-based block detector for a SPECT/MRI system and tested its performance by combining 1.2 ×1.2 ×6 mm Y2SiO5 (YSO) pixels into a 15 ×15 block and was coupled it to an optical fiber image guide that used was 0.5-mm in diameter with 80-cm long double clad fibers. The image guide had 22 ×22 mm rectangular input and an equal size output. The input of the optical fiber-based image guide was bent at 90 degrees, and the output was optically coupled to a 1-in square high quantum efficiency position sensitive photomultiplier tube (HQE-PSPMT). The parallel hole, 7-mm-thick collimator made of tungsten plastic was mounted on a YSO block. The diameter of the collimator holes was 0.8 mm which was positioned one-to-one coupled to the YSO pixels. We evaluated the intrinsic and system performances. We resolved most of the YSO pixels in a two-dimensional histogram for Co-57 gamma photons (122-keV) with an average peak-to-value ratio of 1.5. The energy resolution was 38% full-width at half-maximum (FWHM). The system resolution was 1.7-mm FWHM, 1.5 mm from the collimator surface, and the sensitivity was 0.06%. Images of a Co-57 point source could be successfully obtained inside 0.3 T MRI without serious interference. We conclude that the developed optical fiber-based YSO block detector is promising for SPECT/MRI systems.

  15. Scleral topography analysed by optical coherence tomography.

    Science.gov (United States)

    Bandlitz, Stefan; Bäumer, Joachim; Conrad, Uwe; Wolffsohn, James

    2017-08-01

    A detailed evaluation of the corneo-scleral-profile (CSP) is of particular relevance in soft and scleral lenses fitting. The aim of this study was to use optical coherence tomography (OCT) to analyse the profile of the limbal sclera and to evaluate the relationship between central corneal radii, corneal eccentricity and scleral radii. Using OCT (Optos OCT/SLO; Dunfermline, Scotland, UK) the limbal scleral radii (SR) of 30 subjects (11M, 19F; mean age 23.8±2.0SD years) were measured in eight meridians 45° apart. Central corneal radii (CR) and corneal eccentricity (CE) were evaluated using the Oculus Keratograph 4 (Oculus, Wetzlar, Germany). Differences between SR in the meridians and the associations between SR and corneal topography were assessed. Median SR measured along 45° (58.0; interquartile range, 46.8-84.8mm) was significantly (ptopography and may provide additional data useful in fitting soft and scleral contact lenses. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. The MRI appearance of the optic nerve sheath following fenestration for benign intracranial hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sallomi, D.; Taylor, H.; Hibbert, J.; Sanders, M.D.; Spalton, D.J.; Tonge, K. [Guys and St. Thomas` Hospitals, London (United Kingdom)

    1998-09-01

    Optic nerve fenestration is carried out in cases of severe benign intracranial hypertension. This study aimed to monitor the optic nerve sheath appearances and orbital changes that occur following this procedure. The eight patients were all female with an average age of 37.3 years and a range of 20-58 years. The duration of symptoms was 2-6 years. Symptoms included headaches, diplopia and visual obscurations. Examination revealed severe papilledema. All investigations, including MRI, biochemical and immunological tests, were negative. Patients had fenestration of a 2 mm x 3 mm segment of the medial aspect of the optic nerve sheath. Imaging was obtained with a 1 T MRI machine using a head coil. Coronal, axial and sagittal 3 mm contiguous sections using STIR sequences with TR 4900 ms, IT 150 ms and TE 60 ms were obtained. Five patients showed clinical improvement. The post-operative MRI findings in four of these included a decreased volume of cerebrospinal fluid (CSF) around the optic nerve sheaths and a localized collection of fluid within the orbit. There were no MRI changes in the three patients with no clinical improvement. Decreased CSF volume around the optic nerve and a fluid collection within the orbit may indicate a favorable outcome in optic nerve fenestration. (orig.) With 3 figs., 12 refs.

  17. Photo-magnetic imaging: resolving optical contrast at MRI resolution

    International Nuclear Information System (INIS)

    Lin Yuting; Thayer, David; Luk, Alex L; Gulsen, Gultekin; Gao Hao

    2013-01-01

    In this paper, we establish the mathematical framework of a novel imaging technique, namely photo-magnetic imaging (PMI). PMI uses a laser to illuminate biological tissues and measure the induced temperature variations using magnetic resonance imaging (MRI). PMI overcomes the limitation of conventional optical imaging and allows imaging of the optical contrast at MRI spatial resolution. The image reconstruction for PMI, using a finite-element-based algorithm with an iterative approach, is presented in this paper. The quantitative accuracy of PMI is investigated for various inclusion sizes, depths and absorption values. Then, a comparison between conventional diffuse optical tomography (DOT) and PMI is carried out to illustrate the superior performance of PMI. An example is presented showing that two 2 mm diameter inclusions embedded 4.5 mm deep and located side by side in a 25 mm diameter circular geometry medium are recovered as a single 6 mm diameter object with DOT. However, these two objects are not only effectively resolved with PMI, but their true concentrations are also recovered successfully. (paper)

  18. Analog electro-optical readout of SiPMs for compact, low power ToF PET/MRI

    International Nuclear Information System (INIS)

    Bieniosek, Matthew F; Levin, Craig S

    2014-01-01

    The aim of this work is to demonstrate time of flight (ToF) performance from analog electro-optical transmission of SiPM-based PET detector signals. In electro-optical readout schemes, scintillation signals are converted to near-infrared light by a laser diode and transmitted out of the MRI bore with fiber-optics [], greatly reducing the PET system's footprint, power consumption, and mutual interference with the MRI.

  19. Peri-optic nerve infiltration during leukaemic relapse: MRI diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Madani, A.; Christophe, C. [Department of Imaging, Hopital Universitaire des Enfants Reine Fabiola, Brussels (Belgium); Ferster, A.; Dan, B. [Department of Paediatrics, Hopital Universitaire des Enfants Reine Fabiola, Brussels (Belgium)

    2000-01-01

    Background. A 10-year-old boy with a history of acute lymphoblastic leukaemia (ALL), but without previous evidence of central nervous system involvement, presented with seizures 3 years after complete remission. Materials and methods. MRI showed bilateral enlargement of the optic nerves despite normal ophthalmological examination. Results. Only the third cerebrospinal fluid examination showed 2 % blasts without concomitant bone-marrow infiltration. Enlargement of the optic nerves was consistent with bilateral leukaemic peri-optic nerve infiltration. The appearances returned to normal after chemotherapy. Conclusion. The optic nerves are a potential site of relapse in patients with systemic and meningeal ALL, even in the absence of ophthalmological signs. (orig.)

  20. Morphology and Topography of Retinal Pericytes in the Living Mouse Retina Using In Vivo Adaptive Optics Imaging and Ex Vivo Characterization

    Science.gov (United States)

    Schallek, Jesse; Geng, Ying; Nguyen, HoanVu; Williams, David R.

    2013-01-01

    Purpose. To noninvasively image retinal pericytes in the living eye and characterize NG2-positive cell topography and morphology in the adult mouse retina. Methods. Transgenic mice expressing fluorescent pericytes (NG2, DsRed) were imaged using a two-channel, adaptive optics scanning laser ophthalmoscope (AOSLO). One channel imaged vascular perfusion with near infrared light. A second channel simultaneously imaged fluorescent retinal pericytes. Mice were also imaged using wide-field ophthalmoscopy. To confirm in vivo imaging, five eyes were enucleated and imaged in flat mount with conventional fluorescent microscopy. Cell topography was quantified relative to the optic disc. Results. We observed strong DsRed fluorescence from NG2-positive cells. AOSLO revealed fluorescent vascular mural cells enveloping all vessels in the living retina. Cells were stellate on larger venules, and showed banded morphology on arterioles. NG2-positive cells indicative of pericytes were found on the smallest capillaries of the retinal circulation. Wide-field SLO enabled quick assessment of NG2-positive distribution, but provided insufficient resolution for cell counts. Ex vivo microscopy showed relatively even topography of NG2-positive capillary pericytes at eccentricities more than 0.3 mm from the optic disc (515 ± 94 cells/mm2 of retinal area). Conclusions. We provide the first high-resolution images of retinal pericytes in the living animal. Subcellular resolution enabled morphological identification of NG2-positive cells on capillaries showing classic features and topography of retinal pericytes. This report provides foundational basis for future studies that will track and quantify pericyte topography, morphology, and function in the living retina over time, especially in the progression of microvascular disease. PMID:24150762

  1. SECTION 6.2 SURFACE TOPOGRAPHY ANALYSIS

    DEFF Research Database (Denmark)

    Seah, M. P.; De Chiffre, Leonardo

    2005-01-01

    Surface physical analysis, i.e. topography characterisation, encompasses measurement, visualisation, and quantification. This is critical for both component form and for surface finish at macro-, micro- and nano-scales. The principal methods of surface topography measurement are stylus profilometry......, optical scanning techniques, and scanning probe microscopy (SPM). These methods, based on acquisition of topography data from point by point scans, give quantitative information of heights with respect to position. Based on a different approach, the so-called integral methods produce parameters...

  2. Effect of different coating layer on the topography and optical properties of ZnO nanostructured

    Science.gov (United States)

    Mohamed, R.; Mamat, M. H.; Malek, M. F.; Ismail, A. S.; Yusoff, M. M.; Asiah, M. N.; Khusaimi, Z.; Rusop, M.

    2018-05-01

    Magnesium (Mg) and aluminum (Al) co-doped zinc oxide (MAZO) thin films were synthesized on glass substrate by sol-gel spin coating method. MAZO thin films were prepared at different coating layers range from 1 to 9. Atomic Force Microscopy (AFM) was used to investigate the topography of the thin films. According to the AFM results, Root Means Square (RMS) of MAZO thin films was increased from 0.747 to 6.545 nm, with increase of number coating layer from 1 to 9, respectively. The results shown the variation on structural and topography properties of MAZO seed film when it's deposited at different coating layers on glass substrate. The optical properties was analyzed using UV-Vis spectroscopy. The obtained results show that the transmittance spectra was increased as thin films coating layer increases.

  3. Measurement noise of a point autofocus surface topography instrument

    DEFF Research Database (Denmark)

    Feng, Xiaobing; Quagliotti, Danilo; Maculotti, Giacomo

    Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment.......Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment....

  4. Position and width of normal adult optic chiasm as measured in coronal MRI

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Park, Jin Sook

    1994-01-01

    To evaluate the position and transverse dimension of the adult optic chiasm in normal Korean adult. The authors analysed 3D coronal volume images (TR/TE=30/13, flip angle=30 .deg. ) of 136 normal adult subjects without known visual abnormality. All MRI examinations were performed using a 0.5T system. MRI was reviewed retrospectively to determine the position (horizontal and tilted) of the potic chiosm and the transverse dimension of the optic chiasm was measured. Seventy- five (55%) of the 136 normal subjects had horizontal position, and sixty-one (45%) had tilted position. Thirty- eight (62%) of 61 with tilted position showed higher position on the right side, and twenty-three (38%) showed higher position on the side. The average transverse dimension(mean SD) was 15.2 ± 0.7mm in men and 14.6 ± 1.0mm in women. The difference of transverse dimension between men and women was statistically significant. Tilted position of the adult optic chiasm on coronal MRI was seen in approximately half of normal adults. The average of transverse dimension of normal optic chiasm was 15mm

  5. Characterization of the optical grade synthetic quartz by X-ray topography

    International Nuclear Information System (INIS)

    Tanaka, Marcos S.; Suzuki, Carlos K.; Iwasaki, Fumiko

    1996-01-01

    The first initiative to develop a technology to grow the optical grade synthetic quartz in our country has been conducted by the UNICAMP - JICA - ABC Crystals collaboration. This research shows that the solid inclusions concentrations is practically inexistent, less than 0.03 incl/cm 3 , what satisfy the international standard requirements. On the other hand, the characterization studies by X-ray topography enabled us to estimate the dislocation line density of order of 1200 lines/cm 2 . This value is higher than to the usual international standard requirements. From this study, we obtained a full knowledge of defects origin, where the optimization process could be done by using seeds with superior quality. (author)

  6. An anatomical and functional topography of human auditory cortical areas

    Directory of Open Access Journals (Sweden)

    Michelle eMoerel

    2014-07-01

    Full Text Available While advances in magnetic resonance imaging (MRI throughout the last decades have enabled the detailed anatomical and functional inspection of the human brain non-invasively, to date there is no consensus regarding the precise subdivision and topography of the areas forming the human auditory cortex. Here, we propose a topography of the human auditory areas based on insights on the anatomical and functional properties of human auditory areas as revealed by studies of cyto- and myelo-architecture and fMRI investigations at ultra-high magnetic field (7 Tesla. Importantly, we illustrate that - whereas a group-based approach to analyze functional (tonotopic maps is appropriate to highlight the main tonotopic axis - the examination of tonotopic maps at single subject level is required to detail the topography of primary and non-primary areas that may be more variable across subjects. Furthermore, we show that considering multiple maps indicative of anatomical (i.e. myelination as well as of functional properties (e.g. broadness of frequency tuning is helpful in identifying auditory cortical areas in individual human brains. We propose and discuss a topography of areas that is consistent with old and recent anatomical post mortem characterizations of the human auditory cortex and that may serve as a working model for neuroscience studies of auditory functions.

  7. Radiation-induced optic neuropathy 4 years after radiation: report of a case followed up with MRI

    International Nuclear Information System (INIS)

    Piquemal, R.; Renard, J.P.; Cottier, J.P.; Herbreteau, D.; Arsene, S.; Rospars, C.; Lioret, E.; Jan, M.

    1998-01-01

    We report a case of radiation-induced optic neuropathy in a 32-year-old man with Cushing's disease and a recurrent tumour of the left cavernous sinus. The patient experienced rapid, painless loss of vision 4 years after treatment without recurrence of tumour or other visual disorder. MRI showed enlargement and contrast enhancement of the optic chiasm. A year later the patient was almost blind and MRI showed atrophy and persistent contrast enhancement of the chiasm. (orig.)

  8. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lanfermann, Heinrich; Raab, Peter; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-01-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  9. A NEW HIGH RESOLUTION OPTICAL METHOD FOR OBTAINING THE TOPOGRAPHY OF FRACTURE SURFACES IN ROCKS

    Directory of Open Access Journals (Sweden)

    Steven Ogilvie

    2011-05-01

    Full Text Available Surface roughness plays a major role in the movement of fluids through fracture systems. Fracture surface profiling is necessary to tune the properties of numerical fractures required in fluid flow modelling to those of real rock fractures. This is achieved using a variety of (i mechanical and (ii optical techniques. Stylus profilometry is a popularly used mechanical method and can measure surface heights with high precision, but only gives a good horizontal resolution in one direction on the fracture plane. This method is also expensive and simultaneous coverage of the surface is not possible. Here, we describe the development of an optical method which images cast copies of rough rock fractures using in-house developed hardware and image analysis software (OptiProf™ that incorporates image improvement and noise suppression features. This technique images at high resolutions, 15-200 μm for imaged areas of 10 × 7.5 mm and 100 × 133 mm, respectively and a similar vertical resolution (15 μm for a maximum topography of 4 mm. It uses in-house developed hardware and image analysis (OptiProf™ software and is cheap and non-destructive, providing continuous coverage of the fracture surface. The fracture models are covered with dye and fluid thicknesses above the rough surfaces converted into topographies using the Lambert-Beer Law. The dye is calibrated using 2 devices with accurately known thickness; (i a polycarbonate tile with wells of different depths and (ii a wedge-shaped vial made from silica glass. The data from each of the two surfaces can be combined to provide an aperture map of the fracture for the scenario where the surfaces touch at a single point or any greater mean aperture. The topography and aperture maps are used to provide data for the generation of synthetic fractures, tuned to the original fracture and used in numerical flow modelling.

  10. Radiation-induced optic neuropathy 4 years after radiation: report of a case followed up with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Piquemal, R.; Renard, J.P. [Service de Medecine Interne A, Hopital Bretonneau, Tours (France); Cottier, J.P.; Herbreteau, D. [Service de Neuroradiologie, Hopital Bretonneau, Tours (France); Arsene, S.; Rospars, C. [Service d`Ophthalmologie, Hopital Bretonneau, Tpurs (France); Lioret, E.; Jan, M. [Service de Neurochirurgie, Hopital Bretonneau, Tours (France)

    1998-07-01

    We report a case of radiation-induced optic neuropathy in a 32-year-old man with Cushing`s disease and a recurrent tumour of the left cavernous sinus. The patient experienced rapid, painless loss of vision 4 years after treatment without recurrence of tumour or other visual disorder. MRI showed enlargement and contrast enhancement of the optic chiasm. A year later the patient was almost blind and MRI showed atrophy and persistent contrast enhancement of the chiasm. (orig.) With 3 figs., 13 refs.

  11. MRI of optic tract lesions: Review and correlation with visual field defects

    International Nuclear Information System (INIS)

    Fadzli, F.; Ramli, N.; Ramli, N.M.

    2013-01-01

    Visual field defects are a conglomerate of patterns of visual impairment derived from diseases affecting the optic nerve as it extends from the globe to the visual cortex. They are complex signs requiring perimetry or visual confrontation for delineation and are associated with diverse aetiologies. This review considers the chiasmatic and post-chiasmatic causes of visual disturbances, with an emphasis on magnetic resonance imaging (MRI) techniques. Newer MRI sequences are considered, such as diffusion-tensor imaging. MRI images are correlated with perimetric findings in order to demonstrate localization of lesions in the visual pathway. This may serve as a valuable reference tool to clinicians and radiologists in the early diagnostic process of differentiating causes of various visual field defects in daily practice

  12. Crystal quality analysis and improvement using x-ray topography

    International Nuclear Information System (INIS)

    Maj, J.; Goetze, K.; Macrander, A.; Zhong, Y.; Huang, X.; Maj, L.

    2008-01-01

    The Topography X-ray Laboratory of the Advanced Photon Source (APS) at Argonne National Laboratory operates as a collaborative effort with APS users to produce high performance crystals for APS X-ray beamline experiments. For many years the topography laboratory has worked closely with an on-site optics shop to help ensure the production of crystals with the highest quality, most stress-free surface finish possible. It has been instrumental in evaluating and refining methods used to produce high quality crystals. Topographical analysis has shown to be an effective method to quantify and determine the distribution of stresses, to help identify methods that would mitigate the stresses and improve the Rocking curve, and to create CCD images of the crystal. This paper describes the topography process and offers methods for reducing crystal stresses in order to substantially improve the crystal optics.

  13. Incidence of enhancement of the optic nerve/sheath complex in fat-suppression orbit MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Kyu; Yoon, Kwon Ha; Choi, Choong Gon; Suh, Dae Chul [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    1995-04-15

    To elucidate the incidence of Gd-DTPA enhancement of the optic nerve/sheath complex (ONC) in patients with various ophthalmopathies using fat-suppression MRI. Orbit MRI with fat-suppression technique (ChemSat) was performed in 58 patients with normal and various orbital lesions. The fat-suppression MR was done with and without Gd-DTPA injection in all cases. MR findings were reviewed retrospectively in a blind fashion with respect to presence or absence of contrast enhancement of the ONC. Contrast enhancement of the ONC was seen in 86% (6/7) of cavernous sinus lesions, 80% (8/10) of intraconal lesions excluding the ONC, 57% (16/28) of ONC lesions, 38% (3/8) of ocular lesions, and 2% (1/55) of normal orbits. The ONC enhancement was the most common in optic nerve/sheath tumors (10/10), and pseudotumors (6/6), cavernous sinus dural arteriovenous malformations (3/3) and cavernous sinus thrombosis (2/2), and less frequently seen in optic neuritis (3/14). Enhancement of the ONC may be seen in lesions of the cavernous sinus and orbit other than optic nerve/sheath lesion.

  14. MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions

    Directory of Open Access Journals (Sweden)

    Vasilis Ntziachristos

    2002-01-01

    Full Text Available We present the clinical implementation of a novel hybrid system that combines magnetic resonance imaging (MRI and near-infrared (NIR optical measurements for the noninvasive study of breast cancer in vivo. Fourteen patients were studied with a MR-NIR prototype imager and spectrometer. A diffuse optical tomographic scheme employed the MR images as a priori information to implement an image-guided NIR localized spectroscopic scheme. All patients who entered the study also underwent gadolinium-enhanced MRI and biopsy so that the optical findings were crossvalidated with MR readings and histopathology. The technique quantified the oxy-and deoxyhemoglobin of five malignant and nine benign breast lesions in vivo. Breast cancers were found with decreased oxygen saturation and higher blood concentration than most benign lesions. The average hemoglobin concentration ([H] of cancers was 0.130±0.100 mM, and the average hemoglobin saturation (Y was 60±9% compared to [H]=0.018±0.005 mM and Y=69±6% of background tissue. Fibroadenomas exhibited high hemoglobin concentration [H]=0.060±0.010 mM and mild decrease in oxygen saturation Y=67±2%. Cysts and other normal lesions were easily differentiated based on intrinsic contrast information. This novel optical technology can be a significant add-on in MR examinations and can be used to characterize functional parameters of cancers with diagnostic and treatment prognosis potential. It is foreseen that the technique can play a major role in functional activation studies of brain and muscle as well.

  15. Discriminant analysis of functional optical topography for schizophrenia diagnosis

    Science.gov (United States)

    Chuang, Ching-Cheng; Nakagome, Kazuyuki; Pu, Shenghong; Lan, Tsuo-Hung; Lee, Chia-Yen; Sun, Chia-Wei

    2014-01-01

    Abnormal prefrontal function plays a central role in the cognition deficits of schizophrenic patients; however, the character of the relationship between discriminant analysis and prefrontal activation remains undetermined. Recently, evidence of low prefrontal cortex (PFC) activation in individuals with schizophrenia has also been found during verbal fluency tests (VFT) and other cognitive tests with several neuroimaging methods. The purpose of this study is to assess the hemodynamic changes of the PFC and discriminant analysis between schizophrenia patients and healthy controls during VFT task by utilizing functional optical topography. A total of 99 subjects including 53 schizophrenic patients and 46 age- and gender-matched healthy controls were studied. The results showed that the healthy group had larger activation in the right and left PFC than in the middle PFC. Besides, the schizophrenic group showed weaker task performance and lower activation in the whole PFC than the healthy group. The result of the discriminant analysis showed a significant difference with P value <0.001 in six channels (CH 23, 29, 31, 40, 42, 52) between the schizophrenic and healthy groups. Finally, 68.69% and 71.72% of subjects are correctly classified as being schizophrenic or healthy with all 52 channels and six significantly different channels, respectively. Our findings suggest that the left PFC can be a feature region for discriminant analysis of schizophrenic diagnosis.

  16. Comparison of optic disc topography in non-glaucomatous eyes of children with juvenile diabetes mellitus and normal children.

    Science.gov (United States)

    Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen

    2010-01-01

    To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.

  17. Test-retest assessment of cortical activation induced by repetitive transcranial magnetic stimulation with brain atlas-guided optical topography

    Science.gov (United States)

    Tian, Fenghua; Kozel, F. Andrew; Yennu, Amarnath; Croarkin, Paul E.; McClintock, Shawn M.; Mapes, Kimberly S.; Husain, Mustafa M.; Liu, Hanli

    2012-11-01

    Repetitive transcranial magnetic stimulation (rTMS) is a technology that stimulates neurons with rapidly changing magnetic pulses with demonstrated therapeutic applications for various neuropsychiatric disorders. Functional near-infrared spectroscopy (fNIRS) is a suitable tool to assess rTMS-evoked brain responses without interference from the magnetic or electric fields generated by the TMS coil. We have previously reported a channel-wise study of combined rTMS/fNIRS on the motor and prefrontal cortices, showing a robust decrease of oxygenated hemoglobin concentration (Δ[HbO2]) at the sites of 1-Hz rTMS and the contralateral brain regions. However, the reliability of this putative clinical tool is unknown. In this study, we develop a rapid optical topography approach to spatially characterize the rTMS-evoked hemodynamic responses on a standard brain atlas. A hemispherical approximation of the brain is employed to convert the three-dimensional topography on the complex brain surface to a two-dimensional topography in the spherical coordinate system. The test-retest reliability of the combined rTMS/fNIRS is assessed using repeated measurements performed two to three days apart. The results demonstrate that the Δ[HbO2] amplitudes have moderate-to-high reliability at the group level; and the spatial patterns of the topographic images have high reproducibility in size and a moderate degree of overlap at the individual level.

  18. Clinical neuroanatomy - cranial MRI and CT. 4. rev. and enl. ed.; Klinische Neuroanatomie - kranielle MRT und CT

    Energy Technology Data Exchange (ETDEWEB)

    Lanfermann, Heinrich; Raab, Peter [Medizinische Hochschule Hannover (MHH) (Germany). Inst. fuer Diagnostische und Interventionelle Neuroradiologie; Kretschmann, Hans-Joachim; Weinrich, Wolfgang

    2015-07-01

    The book on clinical neuroanatomy - cranial MRI and CT covers the following issues: layered imaging diagnostics and reference structures; frontal layer, sagittal layers, transverse layers, brainstem, skull topography and the intracranial spaces and structures, facial skull topography, head-neck topography; neurofunctional systems, neurotransmitter and neuromodulators, surveillance material and techniques.

  19. Effect of co-doping process on topography, optical and electrical properties of ZnO nanostructured

    Science.gov (United States)

    Mohamed, R.; Mamat, M. H.; Malek, M. F.; Ismail, A. S.; Yusoff, M. M.; Syamsir, S. A.; Khusaimi, Z.; Rusop, M.

    2018-05-01

    We investigated of Undoped ZnO and Magnesium (Mg)-Aluminium (Al) co-doped Zinc Oxide (MAZO) nanostructured films were prepared by sol gel spin coating technique. The surface topography was analyzed using Atomic Force Microscopy (AFM). Based on the AFM results, Root Mean Square (RMS) of MAZO films have rougher surface compared to pure ZnO films. The optical and electrical properties of thin film samples were characterized using Uv-Vis spectroscopy and two point probes, current-voltage (I-V) measurements. The transmittance spectra for both thin samples was above 80% in the visible wavelength. The MAZO film shows the highest conductivity compared to pure ZnO films. This result indicates that the improvement of carrier mobility throughout doping process and possibly contribute by extra ion charge.

  20. Functional topography of single cortical cells: an intracellular approach combined with optical imaging.

    Science.gov (United States)

    Buzás, P; Eysel, U T; Kisvárday, Z F

    1998-11-01

    Pyramidal cells mediating long-range corticocortical connections have been assumed to play an important role in visual perceptual mechanisms [C.D. Gilbert, Horizontal integration and cortical dynamics, Neuron 9 (1992) 1-13]. However, no information is available as yet on the specificity of individual pyramidal cells with respect to functional maps, e.g., orientation map. Here, we show a combination of techniques with which the functional topography of single pyramidal neurons can be explored in utmost detail. To this end, we used optical imaging of intrinsic signals followed by intracellular recording and staining with biocytin in vivo. The axonal and dendritic trees of the labelled neurons were reconstructed in three dimensions and aligned with corresponding functional orientation maps. The results indicate that, contrary to the sharp orientation tuning of neurons shown by the recorded spike activity, the efferent connections (axon terminal distribution) of the same pyramidal cells were found to terminate at a much broader range of orientations. Copyright 1998 Elsevier Science B.V.

  1. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  2. Assessing sensory versus optogenetic network activation by combining (o)fMRI with optical Ca2+ recordings.

    Science.gov (United States)

    Schmid, Florian; Wachsmuth, Lydia; Schwalm, Miriam; Prouvot, Pierre-Hugues; Jubal, Eduardo Rosales; Fois, Consuelo; Pramanik, Gautam; Zimmer, Claus; Faber, Cornelius; Stroh, Albrecht

    2016-11-01

    Encoding of sensory inputs in the cortex is characterized by sparse neuronal network activation. Optogenetic stimulation has previously been combined with fMRI (ofMRI) to probe functional networks. However, for a quantitative optogenetic probing of sensory-driven sparse network activation, the level of similarity between sensory and optogenetic network activation needs to be explored. Here, we complement ofMRI with optic fiber-based population Ca 2+ recordings for a region-specific readout of neuronal spiking activity in rat brain. Comparing Ca 2+ responses to the blood oxygenation level-dependent signal upon sensory stimulation with increasing frequencies showed adaptation of Ca 2+ transients contrasted by an increase of blood oxygenation level-dependent responses, indicating that the optical recordings convey complementary information on neuronal network activity to the corresponding hemodynamic response. To study the similarity of optogenetic and sensory activation, we quantified the density of cells expressing channelrhodopsin-2 and modeled light propagation in the tissue. We estimated the effectively illuminated volume and numbers of optogenetically stimulated neurons, being indicative of sparse activation. At the functional level, upon either sensory or optogenetic stimulation we detected single-peak short-latency primary Ca 2+ responses with similar amplitudes and found that blood oxygenation level-dependent responses showed similar time courses. These data suggest that ofMRI can serve as a representative model for functional brain mapping. © The Author(s) 2015.

  3. Assessing sensory versus optogenetic network activation by combining (o)fMRI with optical Ca2+ recordings

    Science.gov (United States)

    Schmid, Florian; Wachsmuth, Lydia; Schwalm, Miriam; Prouvot, Pierre-Hugues; Jubal, Eduardo Rosales; Fois, Consuelo; Pramanik, Gautam; Zimmer, Claus; Stroh, Albrecht

    2015-01-01

    Encoding of sensory inputs in the cortex is characterized by sparse neuronal network activation. Optogenetic stimulation has previously been combined with fMRI (ofMRI) to probe functional networks. However, for a quantitative optogenetic probing of sensory-driven sparse network activation, the level of similarity between sensory and optogenetic network activation needs to be explored. Here, we complement ofMRI with optic fiber-based population Ca2+ recordings for a region-specific readout of neuronal spiking activity in rat brain. Comparing Ca2+ responses to the blood oxygenation level-dependent signal upon sensory stimulation with increasing frequencies showed adaptation of Ca2+ transients contrasted by an increase of blood oxygenation level-dependent responses, indicating that the optical recordings convey complementary information on neuronal network activity to the corresponding hemodynamic response. To study the similarity of optogenetic and sensory activation, we quantified the density of cells expressing channelrhodopsin-2 and modeled light propagation in the tissue. We estimated the effectively illuminated volume and numbers of optogenetically stimulated neurons, being indicative of sparse activation. At the functional level, upon either sensory or optogenetic stimulation we detected single-peak short-latency primary Ca2+ responses with similar amplitudes and found that blood oxygenation level-dependent responses showed similar time courses. These data suggest that ofMRI can serve as a representative model for functional brain mapping. PMID:26661247

  4. Simultaneous pressure-volume measurements using optical sensors and MRI for left ventricle function assessment during animal experiment.

    Science.gov (United States)

    Abi-Abdallah Rodriguez, Dima; Durand, Emmanuel; de Rochefort, Ludovic; Boudjemline, Younes; Mousseaux, Elie

    2015-01-01

    Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Development of material measures for performance verifying surface topography measuring instruments

    International Nuclear Information System (INIS)

    Leach, Richard; Giusca, Claudiu; Rickens, Kai; Riemer, Oltmann; Rubert, Paul

    2014-01-01

    The development of two irregular-geometry material measures for performance verifying surface topography measuring instruments is described. The material measures are designed to be used to performance verify tactile and optical areal surface topography measuring instruments. The manufacture of the material measures using diamond turning followed by nickel electroforming is described in detail. Measurement results are then obtained using a traceable stylus instrument and a commercial coherence scanning interferometer, and the results are shown to agree to within the measurement uncertainties. The material measures are now commercially available as part of a suite of material measures aimed at the calibration and performance verification of areal surface topography measuring instruments

  6. MRI in Optic Neuritis: Structure, Function, Interactions

    DEFF Research Database (Denmark)

    Fuglø, Dan

    2011-01-01

    resonance imaging (MRI), and the visual evoked potential (VEP) continues to show a delayed P100 indicating persistent demyelination. The explanation for this apparent discrepancy between structure and function could be due to either a redundancy in the visual pathways so that some degree of signal loss...... will have very few or no clinical symptoms, or it could be due to compensatory mechanisms in the visual pathway or the visual cortex. In order to understand the pathophysiology and recovery processes in ON it is essential to have sensitive methods to asses both structure and function. These methods...... are low. Functional MRI (fMRI) is a non-invasive technique that can measure brain activity with a high spatial resolution. Recently, technical and methodological advancements have made it feasible to record VEPs and fMRI simultaneously and the relationship between averaged VEPs and averaged fMRI signals...

  7. Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis

    DEFF Research Database (Denmark)

    Langkilde, Annika Reynberg; Frederiksen, J.L.; Rostrup, Egill

    2002-01-01

    to both the results of the contrast sensitivity test and to the Snellen visual acuity. Our results indicate that fMRI is a useful method for the study of ON, even in cases where the visual acuity is severely impaired. The reduction in activated volume could be explained as a reduced neuronal input......The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size...... of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed...

  8. Muscle MRI STIR signal intensity and atrophy are correlated to focal lower limb neuropathy severity.

    Science.gov (United States)

    Deroide, N; Bousson, V; Mambre, L; Vicaut, E; Laredo, J D; Kubis, Nathalie

    2015-03-01

    The objective is to determine if muscle MRI is useful for assessing neuropathy severity. Clinical, MRI and electromyography (EMG) examinations were performed in 17 patients with focal lower limb neuropathies. MRI Short Tau Inversion Recovery (STIR) signal intensity, amyotrophy, and muscle fatty infiltration measured after T1-weighted image acquisition, EMG spontaneous activity (SA), and maximal voluntary contraction (MVC) were graded using semiquantitative scores and quantitative scores for STIR signal intensity and were correlated to the Medical Research Council (MRC) score for testing muscle strength. Within this population, subgroups were selected according to severity (mild versus severe), duration (subacute versus chronic), and topography (distal versus proximal) of the neuropathy. EMG SA and MVC MRI amyotrophy and quantitative scoring of muscle STIR intensity were correlated with the MRC score. Moreover, MRI amyotrophy was significantly increased in severe, chronic, and proximal neuropathies along with fatty infiltration in chronic lesions. Muscle MRI atrophy and quantitative evaluation of signal intensity were correlated to MRC score in our study. Semiquantitative evaluation of muscle STIR signal was sensitive enough for detection of topography of the nerve lesion but was not suitable to assess severity. Muscle MRI could support EMG in chronic and proximal neuropathy, which showed poor sensitivity in these patients.

  9. Muscle MRI STIR signal intensity and atrophy are correlated to focal lower limb neuropathy severity

    Energy Technology Data Exchange (ETDEWEB)

    Deroide, N.; Mambre, L.; Kubis, Nathalie [Service de Physiologie Clinique-Explorations Fonctionnelles, AP-HP, Hopital Lariboisiere, Paris (France); Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); Bousson, V.; Laredo, J.D. [Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); Radiologie Osteo-articulaire, AP-HP, Hopital Lariboisiere, Paris (France); Vicaut, E. [Universite Paris Diderot, Sorbonne Paris Cite France, Paris (France); URC, AP-HP, Hopital Lariboisiere, Paris (France)

    2014-09-26

    The objective is to determine if muscle MRI is useful for assessing neuropathy severity. Clinical, MRI and electromyography (EMG) examinations were performed in 17 patients with focal lower limb neuropathies. MRI Short Tau Inversion Recovery (STIR) signal intensity, amyotrophy, and muscle fatty infiltration measured after T1-weighted image acquisition, EMG spontaneous activity (SA), and maximal voluntary contraction (MVC) were graded using semiquantitative scores and quantitative scores for STIR signal intensity and were correlated to the Medical Research Council (MRC) score for testing muscle strength. Within this population, subgroups were selected according to severity (mild versus severe), duration (subacute versus chronic), and topography (distal versus proximal) of the neuropathy. EMG SA and MVC MRI amyotrophy and quantitative scoring of muscle STIR intensity were correlated with the MRC score. Moreover, MRI amyotrophy was significantly increased in severe, chronic, and proximal neuropathies along with fatty infiltration in chronic lesions. Muscle MRI atrophy and quantitative evaluation of signal intensity were correlated to MRC score in our study. Semiquantitative evaluation of muscle STIR signal was sensitive enough for detection of topography of the nerve lesion but was not suitable to assess severity. Muscle MRI could support EMG in chronic and proximal neuropathy, which showed poor sensitivity in these patients. (orig.)

  10. Free induction decay MR signal measurements toward ultra-low field MRI with an optically pumped atomic magnetometer.

    Science.gov (United States)

    Oida, Takenori; Kobayashi, Tetsuo

    2013-01-01

    Ultra-low field magnetic resonance imaging (ULF-MRI) has attracted attention because of its low running costs and minimum patient exposure. An optically pumped atomic magnetometer (OPAM) is a magnetic sensor with high sensitivity in the low frequency range, which does not require a cryogenic cooling system. In an effort to develop a ULF-MRI, we attempted to measure the free induction decay MR signals with an OPAM. We successfully detected the MR signals by combining an OPAM and a flux transformer, demonstrating the feasibility of the proposed system.

  11. Payload topography camera of Chang'e-3

    International Nuclear Information System (INIS)

    Yu, Guo-Bin; Liu, En-Hai; Zhao, Ru-Jin; Zhong, Jie; Zhou, Xiang-Dong; Zhou, Wu-Lin; Wang, Jin; Chen, Yuan-Pei; Hao, Yong-Jie

    2015-01-01

    Chang'e-3 was China's first soft-landing lunar probe that achieved a successful roving exploration on the Moon. A topography camera functioning as the lander's “eye” was one of the main scientific payloads installed on the lander. It was composed of a camera probe, an electronic component that performed image compression, and a cable assembly. Its exploration mission was to obtain optical images of the lunar topography in the landing zone for investigation and research. It also observed rover movement on the lunar surface and finished taking pictures of the lander and rover. After starting up successfully, the topography camera obtained static images and video of rover movement from different directions, 360° panoramic pictures of the lunar surface around the lander from multiple angles, and numerous pictures of the Earth. All images of the rover, lunar surface, and the Earth were clear, and those of the Chinese national flag were recorded in true color. This paper describes the exploration mission, system design, working principle, quality assessment of image compression, and color correction of the topography camera. Finally, test results from the lunar surface are provided to serve as a reference for scientific data processing and application. (paper)

  12. An optically coupled system for quantitative monitoring of MRI-induced RF currents into long conductors.

    Science.gov (United States)

    Zanchi, Marta G; Venook, Ross; Pauly, John M; Scott, Greig C

    2010-01-01

    The currents induced in long conductors such as guidewires by the radio-frequency (RF) field in magnetic resonance imaging (MRI) are responsible for potentially dangerous heating of surrounding media, such as tissue. This paper presents an optically coupled system with the potential to quantitatively measure the RF currents induced on these conductors. The system uses a self shielded toroid transducer and active circuitry to modulate a high speed light-emitting-diode transmitter. Plastic fiber guides the light to a photodiode receiver and transimpedance amplifier. System validation included a series of experiments with bare wires that compared wire tip heating by fluoroptic thermometers with the RF current sensor response. Validations were performed on a custom whole body 64 MHz birdcage test platform and on a 1.5 T MRI scanner. With this system, a variety of phenomena were demonstrated including cable trap current attenuation, lossy dielectric Q-spoiling and even transverse electromagnetic wave node patterns. This system should find applications in studies of MRI RF safety for interventional devices such as pacemaker leads, and guidewires. In particular, variations of this device could potentially act as a realtime safety monitor during MRI guided interventions.

  13. An Optically-Coupled System for Quantitative Monitoring of MRI-Induced RF Currents into Long Conductors

    Science.gov (United States)

    Zanchi, Marta G.; Venook, Ross; Pauly, John M.; Scott, Greig C.

    2010-01-01

    The currents induced in long conductors such as guidewires by the radio frequency (RF) field in magnetic resonance imaging (MRI) are responsible for potentially dangerous heating of surrounding media, such as tissue. This paper presents an optically-coupled system with the potential to quantitatively measure the RF currents induced on these conductors. The system uses a self shielded toroid transducer and active circuitry to modulate a high speed LED transmitter. Plastic fiber guides the light to a photodiode receiver and transimpedance amplifier. System validation included a series of experiments with bare wires that compared wire tip heating by fluoroptic thermometers with the RF current sensor response. Validations were performed on a custom whole body 64 MHz birdcage test platform and on a 1.5T MRI scanner. With this system, a variety of phenomena were demonstrated including cable trap current attenuation, lossy dielectric Q-spoiling and even transverse electromagnetic wave node patterns. This system should find applications in studies of MRI RF safety for interventional devices such as pacemaker leads, and guidewires. In particular, variations of this device could potentially act as a realtime safety monitor during MRI guided interventions. PMID:19758855

  14. Open questions in surface topography measurement: a roadmap

    International Nuclear Information System (INIS)

    Leach, Richard; Evans, Christopher; He, Liangyu; Davies, Angela; Duparré, Angela; Henning, Andrew; Jones, Christopher W; O’Connor, Daniel

    2015-01-01

    Control of surface topography has always been of vital importance for manufacturing and many other engineering and scientific disciplines. However, despite over one hundred years of quantitative surface topography measurement, there are still many open questions. At the top of the list of questions is ‘Are we getting the right answer?’ This begs the obvious question ‘How would we know?’ There are many other questions relating to applications, the appropriateness of a technique for a given scenario, or the relationship between a particular analysis and the function of the surface. In this first ‘open questions’ article we have gathered together some experts in surface topography measurement and asked them to address timely, unresolved questions about the subject. We hope that their responses will go some way to answer these questions, address areas where further research is required, and look at the future of the subject. The first section ‘Spatial content characterization for precision surfaces’ addresses the need to characterise the spatial content of precision surfaces. Whilst we have been manufacturing optics for centuries, there still isn’t a consensus on how to specify the surface for manufacture. The most common three methods for spatial characterisation are reviewed and compared, and the need for further work on quantifying measurement uncertainties is highlighted. The article is focussed on optical surfaces, but the ideas are more pervasive. Different communities refer to ‘figure, mid-spatial frequencies, and finish’ and ‘form, waviness, and roughness’, but the mathematics are identical. The second section ‘Light scattering methods’ is focussed on light scattering techniques; an important topic with in-line metrology becoming essential in many manufacturing scenarios. The potential of scattering methods has long been recognized; in the ‘smooth surface limit’ functionally significant relationships can be derived from first

  15. Relevance of CT and MRI in retinoblastoma for the diagnosis of postlaminar invasion with normal-size optic nerve: a retrospective study of 150 patients with histological comparison

    International Nuclear Information System (INIS)

    Brisse, Herve J.; Guesmi, Myriam; Neuenschwander, Sylvia; Aerts, Isabelle; Sastre-Garau, Xavier; Savignoni, Alexia; Asselain, Bernard; Bours, Daniele; Lumbroso-Le Rouic, Livia; Desjardins, Laurence; Doz, Francois

    2007-01-01

    Detection of optic nerve invasion is mandatory in children primarily enucleated for retinoblastoma to ensure a free resection margin. To assess the accuracy of CT and MRI for the detection of postlaminar invasion in normal-size nerves. A total of 150 patients enucleated for retinoblastoma were included. Imaging data (119 CT and 46 MRI) were retrospectively reviewed and compared with histological findings. Abnormal contrast enhancement of the optic nerve was used as diagnostic criterion for invasion. The associations between postlaminar invasion and several indirect signs were also assessed. Statistical analysis was performed with the Kruskal-Wallis and Fisher exact tests. Postlaminar invasion on histology was observed in 8% (12/150). The sensitivity, specificity, accuracy and negative and positive predictive values were 60%, 95%, 91%, 95% and 60% for MRI, and 0%, 100%, 94% and 94% (PPV not assessable) for CT, respectively. Tumour diameter was the only indirect radiological sign significantly associated with postlaminar optic nerve invasion (P=0.002). Our results suggest that MRI is more relevant than CT for preoperative detection of optic nerve invasion in patients with retinoblastoma. Tumour diameter is the only indirect sign significantly associated with postlaminar invasion. (orig.)

  16. Relevance of CT and MRI in retinoblastoma for the diagnosis of postlaminar invasion with normal-size optic nerve: a retrospective study of 150 patients with histological comparison

    Energy Technology Data Exchange (ETDEWEB)

    Brisse, Herve J.; Guesmi, Myriam; Neuenschwander, Sylvia [Institute Curie, Department of Radiology, Paris (France); Aerts, Isabelle [Institute Curie, Department of Paediatric Oncology, Paris (France); Sastre-Garau, Xavier [Institute Curie, Department of Pathology, Paris (France); Savignoni, Alexia; Asselain, Bernard; Bours, Daniele [Institute Curie, Department of Biostatistics, Paris (France); Lumbroso-Le Rouic, Livia; Desjardins, Laurence [Institute Curie, Department of Ocular Oncology, Paris (France); Doz, Francois [Institute Curie, Department of Paediatric Oncology, Paris (France); Faculty of Medicine, Department of Paediatrics, Paris (France)

    2007-07-15

    Detection of optic nerve invasion is mandatory in children primarily enucleated for retinoblastoma to ensure a free resection margin. To assess the accuracy of CT and MRI for the detection of postlaminar invasion in normal-size nerves. A total of 150 patients enucleated for retinoblastoma were included. Imaging data (119 CT and 46 MRI) were retrospectively reviewed and compared with histological findings. Abnormal contrast enhancement of the optic nerve was used as diagnostic criterion for invasion. The associations between postlaminar invasion and several indirect signs were also assessed. Statistical analysis was performed with the Kruskal-Wallis and Fisher exact tests. Postlaminar invasion on histology was observed in 8% (12/150). The sensitivity, specificity, accuracy and negative and positive predictive values were 60%, 95%, 91%, 95% and 60% for MRI, and 0%, 100%, 94% and 94% (PPV not assessable) for CT, respectively. Tumour diameter was the only indirect radiological sign significantly associated with postlaminar optic nerve invasion (P=0.002). Our results suggest that MRI is more relevant than CT for preoperative detection of optic nerve invasion in patients with retinoblastoma. Tumour diameter is the only indirect sign significantly associated with postlaminar invasion. (orig.)

  17. Stromal demarcation line induced by corneal cross-linking in eyes with keratoconus and nonkeratoconic asymmetric topography.

    Science.gov (United States)

    Malta, João B N; Renesto, Adimara C; Moscovici, Bernardo K; Soong, H K; Campos, Mauro

    2015-02-01

    To evaluate stromal demarcation lines following corneal cross-linking (CXL) using anterior segment optical coherence tomography in patients with keratoconus and nonkeratoconic asymmetric topography. Fifth-nine eyes of 59 patients were enrolled in a retrospective comparative case series, of which 19 eyes had keratoconus and 40 eyes had asymmetric topography. Eyes with asymmetric topography were treated in preparation for photorefractive keratectomy. One month after CXL, a stromal demarcation line was evaluated at 5 standardized corneal points using anterior segment optical coherence tomography. Mean stromal demarcation line depths were measured at 5 points on the cornea, namely, centrally, 3.0 mm temporally, 1.5 mm temporally, 3.0 mm nasally, and 1.5 mm nasally. For the keratoconus group, the values were 178 ± 47, 123 ± 15, 152 ± 47, 125 ± 23, and 160 ± 43 μm, respectively. For the asymmetric corneal topography group (without keratoconus), they were 305 ± 64, 235 ± 57, 294 ± 50, 214 ± 54, and 285 ± 58 μm, respectively. There was no correlation between central corneal pachymetry and stromal demarcation line depth in all 5 measured corneal points in both groups. CXL treatment profiles are similar in keratoconic and nonkeratoconic eyes with asymmetric topography.

  18. A novel optically transparent RF shielding for fully integrated PET/MRI systems

    Science.gov (United States)

    Parl, C.; Kolb, A.; Schmid, A. M.; Wehrl, H. F.; Disselhorst, J. A.; Soubiran, P. D.; Stricker-Shaver, D.; Pichler, B. J.

    2017-09-01

    Preclinical imaging benefits from simultaneous acquisition of high-resolution anatomical and molecular data. Additionally, PET/MRI systems can provide functional PET and functional MRI data. To optimize PET sensitivity, we propose a system design that fully integrates the MRI coil into the PET system. This allows positioning the scintillators near the object but requires an optimized design of the MRI coil and PET detector. It further requires a new approach in realizing the radiofrequency (RF) shielding. Thus, we propose the use of an optically transparent RF shielding material between the PET scintillator and the light sensor, suppressing the interference between both systems. We evaluated two conductive foils (ITO, 9900) and a wire mesh. The PET performance was tested on a dual-layer scintillator consisting of 12  ×  12 LSO matrices, shifted by half a pitch. The pixel size was 0.9  ×  0.9 mm2 the lengths were 10.0 mm and 5.0 mm, respectively. For a light sensor, we used a 4  ×  4 SiPM array. The RF attenuation was measured from 320 kHz to 420 MHz using two pick-up coils. MRI-compatibility and shielding effect of the materials were evaluated with an MRI system. The average FWHM energy resolution at 511 keV of all 144 crystals of the layer next to the SiPM was deteriorated from 15.73  ±  0.24% to 16.32  ±  0.13%, 16.60  ±  0.25%, and 19.16  ±  0.21% by the ITO foil, 9900 foil, mesh material, respectively. The average peak-to-valley ratio of the PET detector changed from 5.77  ±  0.29 to 4.50  ±  0.39, 4.78  ±  0.48, 3.62  ±  0.16, respectively. The ITO, 9900, mesh attenuated the scintillation light by 11.3  ±  1.6%, 11.0  ±  1.8%, 54.3  ±  0.4%, respectively. To attenuate the RF from 20 MHz to 200 MHz, mesh performed better than copper. The results show that an RF shielding material that is sufficiently transparent for

  19. Lesion discrimination in optic neuritis using high-resolution fat-suppressed fast spin-echo MRI

    International Nuclear Information System (INIS)

    Gass, A.; Moseley, I.F.; Barker, G.J.; Jones, S.; MacManus, D.; McDonald, W.I.; Miller, D.H.

    1996-01-01

    Fast spin-echo (FSE) is a new sequence with acquisition times currently down to one-sixteenth of those obtained with conventional spin-echo sequences, which allows high-resolution (512 x 512 matrix) images to be acquired in an acceptable time. We compared the higher resolution of FSE with the medium resolution of a short inversion-time inversion-recovery (STIR) sequence in depicting the optic nerves of healthy controls and patients with optic neuritis. Optic nerve MRI examinations were performed in 18 patients with optic neuritis and 10 normal controls. Two sequences were obtained coronally: fat-suppressed FSE (FSE TR 3250 ms/TEef 68 ms, echo-train length 16, 4 excitations, 24 cm rectangular field of view, 3 mm interleaved contiguous slices, in-plane resolution 0.5 x 0.5 mm) and STIR (TR 2000 ms/TE 50 ms/TI 175 ms, in-plane resolution 0.8 x 0.8 mm, slice thickness 5 mm). FSE demonstrated much more anatomical detail than STIR, e. g. distinction of optic nerve and sheath. Lesions were seen in 20 of 21 symptomatic nerves using FSE and in 18 of 21 using STIR. Nerve swelling or partial cross-sectional lesions of the optic nerve were each seen only on FSE in 3 cases. Fat-suppressed FSE imaging of the optic nerve improves anatomical definition and increases lesion detection in optic neuritis. (orig.). With 5 figs

  20. Topography of the Betics: crustal thickening, dynamic topography and relief inheritance

    Science.gov (United States)

    Janowski, Marianne; Loget, Nicolas; Bellahsen, Nicolas; Husson, Laurent; Le Pourhiet, Laetitia; Meyer, Bertrand

    2017-04-01

    The main mechanism that explains high orogenic topographies is the isostatic adjustment due to crustal thickening. However in the Betic Cordillera (South Spain), the present-day elevation and crustal thickness are not correlated. That is at odds with the general premise of isostasy and requires reappraising the question of the driving mechanisms leading to the current topography. The Betics are located at the western edge of the alpine Mediterranean belt. Its Cenozoic orogenic building was disrupted by a major crustal thinning event induced by a slab rollback in the internal zones (Alboran domain) during Neogene. Topography was largely levelled and flooded by the sea during Neogene extension, and then has been folded since the Late Tortonian inversion. The present-day topography shows flat summits still preserved from fluvial regression in the internal zones (central and eastern Betics). These low-relief surfaces may be inherited from the Neogene planation toward sea-level as rocks cooling histories inferred from low-temperature thermochronology seem to point it out. Post-Tortonian shortening estimated thanks to a crustal-scale N-S cross-section in the eastern Betics (at the Sierra Nevada longitude) does not exceed few kilometers which is much lower than the shortening required by isostatic equilibrium, and is thus insufficient to explain the post-Tortonian topography building. We tested the hypothesis that mantle dynamics could in fact be an important mechanism that explains the topography of the Betics. We first computed the residual topography (i.e. the non-isostatic component of the elevation) using the most recent published Moho mapping of the area. In the western Betics, our results show important negative residual topography (down to -3 km) possibly associated with the west-Alboran slab suction. In the eastern Betics however, positive residual topography is important (up to +3 km) and can be explained by the dynamic mantle support of the topography, possibly

  1. Topography measurements and applications in ballistics and tool mark identifications*

    Science.gov (United States)

    Vorburger, T V; Song, J; Petraco, N

    2016-01-01

    The application of surface topography measurement methods to the field of firearm and toolmark analysis is fairly new. The field has been boosted by the development of a number of competing optical methods, which has improved the speed and accuracy of surface topography acquisitions. We describe here some of these measurement methods as well as several analytical methods for assessing similarities and differences among pairs of surfaces. We also provide a few examples of research results to identify cartridge cases originating from the same firearm or tool marks produced by the same tool. Physical standards and issues of traceability are also discussed. PMID:27182440

  2. Impact of gastric acidic challenge on surface topography and optical properties of monolithic zirconia.

    Science.gov (United States)

    Sulaiman, Taiseer A; Abdulmajeed, Aous A; Shahramian, Khalil; Hupa, Leena; Donovan, Terrence E; Vallittu, Pekka; Närhi, Timo O

    2015-12-01

    To evaluate the surface topography and optical properties of monolithic zirconia after immersion in simulated gastric acid. Four partially stabilized (PSZ) and one fully stabilized (FSZ) zirconia materials were selected for the study: Prettau (PRT, Zirkonzahn), Zenostar (ZEN, Ivoclar), Bruxzir (BRX, Glidewell), Katana (KAT, Noritake) and FSZ Prettau Anterior (PRTA, Zirkonzahn). IPS e.max (Ivoclar) was used as a control. The specimens (10×10×1.2mm, n=5 per material) were cut, sintered, polished and cleaned before immersed in 5ml of simulated gastric acid solution (Hydrochloric acid (HCl) 0.06M, 0.113% solution in deionized distal water, pH 1.2) for 96h in a 37°C incubator. Specimens were weighed and examined for morphological changes under scanning electron microscope (SEM) coupled with energy dispersive X-ray spectroscopy (EDX). Surface roughness was evaluated by a confocal microscope. Surface gloss and translucency parameter (TP) values were determined by a reflection spectrophotometer before and after acid immersion. The data was analyzed by one-way ANOVA followed by Tukey's HSD post hoc test (pgloss of ZEN, PRTA and IPS e.max increased (p<0.05). Monolithic zirconia materials show some surface alterations in an acidic environment with minimum effect on their optical properties. Whether a smoother surface is in fact a sign of true corrosion resistance or is purely the result of an evenly progressive corrosive process is yet to be confirmed by further research. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Dynamic Topography Revisited

    Science.gov (United States)

    Moresi, Louis

    2015-04-01

    Dynamic Topography Revisited Dynamic topography is usually considered to be one of the trinity of contributing causes to the Earth's non-hydrostatic topography along with the long-term elastic strength of the lithosphere and isostatic responses to density anomalies within the lithosphere. Dynamic topography, thought of this way, is what is left over when other sources of support have been eliminated. An alternate and explicit definition of dynamic topography is that deflection of the surface which is attributable to creeping viscous flow. The problem with the first definition of dynamic topography is 1) that the lithosphere is almost certainly a visco-elastic / brittle layer with no absolute boundary between flowing and static regions, and 2) the lithosphere is, a thermal / compositional boundary layer in which some buoyancy is attributable to immutable, intrinsic density variations and some is due to thermal anomalies which are coupled to the flow. In each case, it is difficult to draw a sharp line between each contribution to the overall topography. The second definition of dynamic topography does seem cleaner / more precise but it suffers from the problem that it is not measurable in practice. On the other hand, this approach has resulted in a rich literature concerning the analysis of large scale geoid and topography and the relation to buoyancy and mechanical properties of the Earth [e.g. refs 1,2,3] In convection models with viscous, elastic, brittle rheology and compositional buoyancy, however, it is possible to examine how the surface topography (and geoid) are supported and how different ways of interpreting the "observable" fields introduce different biases. This is what we will do. References (a.k.a. homework) [1] Hager, B. H., R. W. Clayton, M. A. Richards, R. P. Comer, and A. M. Dziewonski (1985), Lower mantle heterogeneity, dynamic topography and the geoid, Nature, 313(6003), 541-545, doi:10.1038/313541a0. [2] Parsons, B., and S. Daly (1983), The

  4. Flow Around Steep Topography

    Science.gov (United States)

    2015-09-30

    Flow around steep topography T. M. Shaun Johnston Scripps Institution of Oceanography University of California, San Diego 9500 Gilman Drive, M...tall, steep, submarine topography and islands. During the Flow Encountering Abrupt Topography (FLEAT) DRI, investigators will determine: • Whether...estimates from making accurate statistical/deterministic predictions at ᝺ km resolution around submarine topography and islands? How can we

  5. Monitoring Cell Death in Regorafenib-Treated Experimental Colon Carcinomas Using Annexin-Based Optical Fluorescence Imaging Validated by Perfusion MRI.

    Directory of Open Access Journals (Sweden)

    Philipp M Kazmierczak

    Full Text Available To investigate annexin-based optical fluorescence imaging (OI for monitoring regorafenib-induced early cell death in experimental colon carcinomas in rats, validated by perfusion MRI and multiparametric immunohistochemistry.Subcutaneous human colon carcinomas (HT-29 in athymic rats (n = 16 were imaged before and after a one-week therapy with regorafenib (n = 8 or placebo (n = 8 using annexin-based OI and perfusion MRI at 3 Tesla. Optical signal-to-noise ratio (SNR and MRI tumor perfusion parameters (plasma flow PF, mL/100mL/min; plasma volume PV, % were assessed. On day 7, tumors underwent immunohistochemical analysis for tumor cell apoptosis (TUNEL, proliferation (Ki-67, and microvascular density (CD31.Apoptosis-targeted OI demonstrated a tumor-specific probe accumulation with a significant increase of tumor SNR under therapy (mean Δ +7.78±2.95, control: -0.80±2.48, p = 0.021. MRI detected a significant reduction of tumor perfusion in the therapy group (mean ΔPF -8.17±2.32 mL/100 mL/min, control -0.11±3.36 mL/100 mL/min, p = 0.036. Immunohistochemistry showed significantly more apoptosis (TUNEL; 11392±1486 vs. 2921±334, p = 0.001, significantly less proliferation (Ki-67; 1754±184 vs. 2883±323, p = 0.012, and significantly lower microvascular density (CD31; 107±10 vs. 182±22, p = 0.006 in the therapy group.Annexin-based OI allowed for the non-invasive monitoring of regorafenib-induced early cell death in experimental colon carcinomas, validated by perfusion MRI and multiparametric immunohistochemistry.

  6. Temporal comparison of functional brain imaging with diffuse optical tomography and fMRI during rat forepaw stimulation

    International Nuclear Information System (INIS)

    Siegel, Andrew M; Culver, Joseph P; Mandeville, Joseph B; Boas, David A

    2003-01-01

    The time courses of oxyhaemoglobin ([HbO 2 ]), deoxyhaemoglobin ([HbR]) and total haemoglobin ([HbT]) concentration changes following cortical activation in rats by electrical forepaw stimulation were measured using diffuse optical tomography (DOT) and compared to similar measurements performed previously with fMRI at 2.0 T and 4.7 T. We also explored the qualitative effects of varying stimulus parameters on the temporal evolution of the hemodynamic response. DOT images were reconstructed at a depth of 1.5 mm over a 1 cm square area from 2 mm anterior to bregma to 8 mm posterior to bregma. The measurement set included 9 sources and 16 detectors with an imaging frame rate of 10 Hz. Both DOT [HbR] and [HbO 2 ] time courses were compared to the fMRI BOLD time course during stimulation, and the DOT [HbT] time course was compared to the fMRI cerebral plasma volume (CPV) time course. We believe that DOT and fMRI can provide similar temporal information for both blood volume and deoxyhaemoglobin changes, which helps to cross-validate these two techniques and to demonstrate that DOT can be useful as a complementary modality to fMRI for investigating the hemodynamic response to neuronal activity

  7. Temporal comparison of functional brain imaging with diffuse optical tomography and fMRI during rat forepaw stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Andrew M [Tufts University Bioengineering Center, Medford, MA 02155 (United States); Culver, Joseph P [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States); Mandeville, Joseph B [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States); Boas, David A [Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129 (United States)

    2003-05-21

    The time courses of oxyhaemoglobin ([HbO{sub 2}]), deoxyhaemoglobin ([HbR]) and total haemoglobin ([HbT]) concentration changes following cortical activation in rats by electrical forepaw stimulation were measured using diffuse optical tomography (DOT) and compared to similar measurements performed previously with fMRI at 2.0 T and 4.7 T. We also explored the qualitative effects of varying stimulus parameters on the temporal evolution of the hemodynamic response. DOT images were reconstructed at a depth of 1.5 mm over a 1 cm square area from 2 mm anterior to bregma to 8 mm posterior to bregma. The measurement set included 9 sources and 16 detectors with an imaging frame rate of 10 Hz. Both DOT [HbR] and [HbO{sub 2}] time courses were compared to the fMRI BOLD time course during stimulation, and the DOT [HbT] time course was compared to the fMRI cerebral plasma volume (CPV) time course. We believe that DOT and fMRI can provide similar temporal information for both blood volume and deoxyhaemoglobin changes, which helps to cross-validate these two techniques and to demonstrate that DOT can be useful as a complementary modality to fMRI for investigating the hemodynamic response to neuronal activity.

  8. Real-Time Correction By Optical Tracking with Integrated Geometric Distortion Correction for Reducing Motion Artifacts in fMRI

    Science.gov (United States)

    Rotenberg, David J.

    Artifacts caused by head motion are a substantial source of error in fMRI that limits its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and non-linear spin-history artifacts, however residual artifacts due to dynamic magnetic field non-uniformity may remain in the data. A recently developed correction technique, PLACE, can correct for absolute geometric distortion using the complex image data from two EPI images, with slightly shifted k-space trajectories. We present a correction approach that integrates PLACE into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an fMRI finger tapping experiment with overt head motion to induce dynamic field non-uniformity. Experiments suggest that including volume by volume geometric distortion correction by PLACE can suppress dynamic geometric distortion artifacts in a phantom and in vivo and provide more robust activation maps.

  9. 4D-visualization of the orbit based on dynamic MRI with special focus on the extra-ocular muscles and the optic nerves

    International Nuclear Information System (INIS)

    Kober, C.; Boerner, B.I.; Buitrago, C.; Klarhoefer, M.; Scheffler, K.; Kunz, C.; Zeilhofer, H.F.

    2007-01-01

    By recording time dependent patients' behaviour, dynamic radiology is dedicated to capturing functional anatomy. Dynamic ''quasi-continuous'' MRI data of lateral eye movements of a healthy volunteer were acquired using SE imaging sequence (Siemens, 1.5 T). By means of combined application of several image processing and visualization techniques, namely shaded and transparent surface reconstruction as well as direct volume rendering, 4D-visualization of the dynamics of the extra ocular muscles was possible. Though the original MRI data were quite coarse vascular structures could be recognized to some extent. For the sake of 4D-visualization of the optic nerve, the optic cavity was opened by axial clipping of the visualization. Superimposition of the original MRI slices to the visualization, either transparently or opaque, served as validation and comparison to conventional diagnosis. For facilitation of the analysis of the visualization results, stereoscopic rendering was rated as quite significant especially in the clinical setting. (orig.)

  10. 3D SEM for surface topography quantification – a case study on dental surfaces

    International Nuclear Information System (INIS)

    Glon, F; Flys, O; Lööf, P-J; Rosén, B-G

    2014-01-01

    3D analysis of surface topography is becoming a more used tool for industry and research. New ISO standards are being launched to assist in quantifying engineering surfaces. The traditional optical measuring instrumentation used for 3D surface characterization has been optical interferometers and confocal based instrumentation. However, the resolution here is limited in the lateral dimension to the wavelength of visible light to about 500 nm. The great advantage using the SEM for topography measurements is the high flexibility to zoom from low magnifications and locating interesting areas to high magnification of down to nanometer large surface features within seconds. This paper presents surface characterization of dental implant micro topography. 3D topography data was created from SEM images using commercial photogrammetric software. A coherence scanning interferometer was used for reference measurements to compare with the 3D SEM measurements on relocated areas. As a result of this study, measurements emphasizes that the correlation between the accepted CSI measurements and the new technology represented by photogrammetry based on SEM images for many areal characterization parameters are around or less than 20%. The importance of selecting sampling and parameter sensitivity to varying sampling is high-lighted. Future work includes a broader study of limitations of the photogrammetry technique on certified micro-geometries and more application surfaces at different scales

  11. Diffusion tensor imaging of occult injury of optic radiation following optic neuritis in multiple sclerosis.

    Science.gov (United States)

    Chen, Jiafeng; Zhu, Lijun; Li, He; Lu, Ziwen; Chen, Xin; Fang, Shaokuan

    2016-10-01

    Multiple sclerosis (MS) is easily detected by routine magnetic resonance imaging (MRI). However, it is not possible to detect early or occult lesions in MS by routine MRI, and this may explain the inconsistency between the severity of the lesions found by MRI and the degree of clinical disability of patients with MS. The present study included 10 patients with relapsing-remitting MS and 10 healthy volunteers. Each patient underwent routine 3.0 T MRI, diffusion tensor imaging (DTI), and diffusion tensor tractography (DTT). Optic nerve and optic radiation were analyzed by DTI and DTT. The fractional anisotropy (FA), mean diffusivity (MD), λ // , and λ ┴ values were measured. In the 10 patients with MS, 7 optic nerves were affected, and 13 optic nerves were not affected. Cranial MRI showed that optic nerve thickening and hyperintensity occurred in 2 patients with MS. In the directionally encoded color maps, a hypointensive green signal in the optic nerve was observed in 3 patients with MS. The FA values were significantly lower and the MD, λ // , and λ ┴ values were significantly higher in the affected and unaffected optic nerves and optic radiations in patients with MS in comparison with controls (P0.05). Diffusion tensor imaging is sensitive in the detection of occult injury of the optic nerve and optic radiation following optic neuritis. Diffusion tensor imaging may be a useful tool for the early diagnosis, treatment and management of MS.

  12. Comparative investigation of optical techniques for topography measurement of rough plastic surfaces

    DEFF Research Database (Denmark)

    Bariani, Paolo; Hansen, Hans Nørgaard; Arlø, Uffe Rolf

    2003-01-01

    An experimental assessment of three-dimensional surface topography characterisation methods for use with rough plastic parts has been carried out. Also, calibration methods and measuring procedures including optimal measuring conditions have been developed and applied. The study is based on rough...

  13. MRI of pituitary adenomas following treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Athanassopoulou, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Rologis, D. [Neurosurgical Clinic, Athens General Hospital (Greece); Kalovidouris, A. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Kotoulas, G. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Vlahos, L. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece); Papavassiliou, C. [Dept. of Radiology, CT and MRI Section, Areteion Hospital, Univ. of Athens (Greece)

    1993-10-01

    The purpose of this study was to assess pituitary adenomas following surgical and/or medical treatment in 28 patients. All patients were evaluated with both computed tomography (CT) and magnetic resonance imaging (MRI). The results were correlated with the clinical findings. Apart from the visualization of the adenoma itself (either residual or recurrent) other findings and in particular, morphological changes of the optic chiasm, the pituitary stalk and the sellar floor were evaluated with both imaging modalities. By comparing the two imaging modalities it was found that MRI was superior to CT in demonstrating residual/recurrent adenoma as well as evaluating the morphological changes of the optic chiasm and optic nerves. CT was superior or equal to MR in demonstrating the sellar floor changes. The intra-operatively implanted fat was equally seen by CT and MR. In conclusion, the anatomical variations of the optic chiasm and pituitary stalk are better visualized by MRI and allow a more precise evaluation of changes attributed to surgical or medical treatment of pituitary adenomas. (orig.)

  14. MRI of pituitary adenomas following treatment

    International Nuclear Information System (INIS)

    Gouliamos, A.; Athanassopoulou, A.; Rologis, D.; Kalovidouris, A.; Kotoulas, G.; Vlahos, L.; Papavassiliou, C.

    1993-01-01

    The purpose of this study was to assess pituitary adenomas following surgical and/or medical treatment in 28 patients. All patients were evaluated with both computed tomography (CT) and magnetic resonance imaging (MRI). The results were correlated with the clinical findings. Apart from the visualization of the adenoma itself (either residual or recurrent) other findings and in particular, morphological changes of the optic chiasm, the pituitary stalk and the sellar floor were evaluated with both imaging modalities. By comparing the two imaging modalities it was found that MRI was superior to CT in demonstrating residual/recurrent adenoma as well as evaluating the morphological changes of the optic chiasm and optic nerves. CT was superior or equal to MR in demonstrating the sellar floor changes. The intra-operatively implanted fat was equally seen by CT and MR. In conclusion, the anatomical variations of the optic chiasm and pituitary stalk are better visualized by MRI and allow a more precise evaluation of changes attributed to surgical or medical treatment of pituitary adenomas. (orig.)

  15. Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI.

    Science.gov (United States)

    Ferradal, Silvina L; Eggebrecht, Adam T; Hassanpour, Mahlega; Snyder, Abraham Z; Culver, Joseph P

    2014-01-15

    Diffuse optical imaging (DOI) is increasingly becoming a valuable neuroimaging tool when fMRI is precluded. Recent developments in high-density diffuse optical tomography (HD-DOT) overcome previous limitations of sparse DOI systems, providing improved image quality and brain specificity. These improvements in instrumentation prompt the need for advancements in both i) realistic forward light modeling for accurate HD-DOT image reconstruction, and ii) spatial normalization for voxel-wise comparisons across subjects. Individualized forward light models derived from subject-specific anatomical images provide the optimal inverse solutions, but such modeling may not be feasible in all situations. In the absence of subject-specific anatomical images, atlas-based head models registered to the subject's head using cranial fiducials provide an alternative solution. In addition, a standard atlas is attractive because it defines a common coordinate space in which to compare results across subjects. The question therefore arises as to whether atlas-based forward light modeling ensures adequate HD-DOT image quality at the individual and group level. Herein, we demonstrate the feasibility of using atlas-based forward light modeling and spatial normalization methods. Both techniques are validated using subject-matched HD-DOT and fMRI data sets for visual evoked responses measured in five healthy adult subjects. HD-DOT reconstructions obtained with the registered atlas anatomy (i.e. atlas DOT) had an average localization error of 2.7mm relative to reconstructions obtained with the subject-specific anatomical images (i.e. subject-MRI DOT), and 6.6mm relative to fMRI data. At the group level, the localization error of atlas DOT reconstruction was 4.2mm relative to subject-MRI DOT reconstruction, and 6.1mm relative to fMRI. These results show that atlas-based image reconstruction provides a viable approach to individual head modeling for HD-DOT when anatomical imaging is not available

  16. Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis

    DEFF Research Database (Denmark)

    Langkilde, Annika Reynberg; Frederiksen, J.L.; Rostrup, Egill

    2002-01-01

    of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed...... a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly......The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size...

  17. The APS optics topography station

    International Nuclear Information System (INIS)

    Krasnicki, S.

    1996-01-01

    An in-house station for topographic testing of x-ray optical elements for the Advanced Photon Source experimental beamlines was set up by the Experimental Facilities Division of Argonne National Laboratory. A new double-crystal x-ray diffractometer was designed and built keeping in mind the need for testing large crystals possibly attached to cooling manifolds and lines. A short description of the new facility is given. The instrument performance fully satisfies imposed requirements, and the machine was successfully used for testing several silicon and diamond crystals

  18. Effects of Polishing Bur Application Force and Reuse on Sintered Zirconia Surface Topography.

    Science.gov (United States)

    Fischer, N G; Tsujimoto, A; Baruth, A G

    2018-03-16

    Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. These in

  19. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    Science.gov (United States)

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  20. Noise evaluation of a point autofocus surface topography measuring instrument

    Science.gov (United States)

    Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard

    2018-06-01

    In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.

  1. Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Zikou, Anastasia K.; Tzovara, Ioanna; Margariti, Persefoni [University of Ioannina, Department of Radiology, Medical School, Ioannina (Greece); Nikas, Alexios; Asproudis, Ioannis [University of Ioannina, Ophthalmologic Clinic, Medical School, Ioannina (Greece); Blekas, Kostandinos; Galatsanos, Nikolaos [University of Ioannina, Department of Informatics, Ioannina (Greece)

    2007-07-15

    The purpose of the study was to examine the brain and the visual pathway of patients with non-arteritic anterior ischaemic optic neuropathy (NAION) by using conventional MRI (cMRI) and volumetric magnetisation transfer imaging (MTI). Thirty NAION patients, aged 67.5 {+-} 8.14 years, and 28 age- and gender-matched controls were studied. MTI was used to measure the magnetisation transfer ratio (MTR) of the chiasm and for MTR histograms of the brain. The presence of areas of white matter hyperintensity (WMH) was evaluated on fluid-attenuated inversion recovery (FLAIR) images. Area of the optic nerves (ONs) and volume of the chiasm were assessed, as were coronal short-tau inversion recovery (STIR) and MTI images, respectively. More areas of WMH were observed in patients (total 419; mean 14.4; SD 19) than in controls (total 127; mean 4.7; SD 5.7), P < 0.001. Area (in square millimetres) of the affected ONs, volume(in cubic millimetres) and MTR (in percent) of the chiasm (10.7 {+-} 4.6), (75.8 {+-} 20.2), (56.4 {+-} 6.5), respectively, were lower in patients than in controls (13.6 {+-} 4.3), (158.2 {+-} 75.3) (62.1 {+-} 6.2), respectively, P < 0.05. Mean MTR of brain histograms was lower in patients (53.0 {+-} 8.0) than in controls (58.0 {+-} 5.6), P < 0.05. NAION is characterised by decreased ON and chiasmatic size. The low MTR of the chiasm and brain associated with increased areas of WMH may be suggestive of demyelination and axonal damage due to generalised cerebral vascular disease. (orig.)

  2. Detection of optic nerve atrophy following a single episode of unilateral optic neuritis by MRI using a fat-saturated short-echo fast FLAIR sequence

    International Nuclear Information System (INIS)

    Hickman, S.J.; Brex, P.A.; Silver, N.C.; Barker, G.J.; Miller, D.H.; Brierley, C.M.H.; Compston, D.A.S.; Scolding, N.J.; Moseley, I.F.; Plant, G.T.

    2001-01-01

    We describe an MRI technique for quantifying optic nerve atrophy resulting from a single episode of unilateral optic neuritis. We imaged 17 patients, with a median time since onset of optic neuritis of 21 months (range 3-81 months), using a coronal-oblique fat-saturated short-echo fast fluid-attenuated inversion-recovery (sTE fFLAIR) sequence. The mean cross-sectional area of the intraorbital portion of the optic nerves was calculated by a blinded observer from five consecutive 3 mm slices from the orbital apex forwards using a semiautomated contouring technique and compared with data from 16 controls. The mean optic nerve area was 11.2mm 2 in the affected eye of the patients, 12.9mm 2 in the contralateral eye (P = 0.006 compared to the affected eye) and 12.8mm 2 in controls (P = 0.03 compared to the affected eyes). There was a significant negative correlation between disease duration and the size of the affected optic nerve (r = -0.59, P = 0.012). The measurement coefficient of variation was 4.8 %. The sTE fFLAIR sequence enables measurement of optic nerve area with sufficient reproducibility to show optic nerve atrophy following a single episode of unilateral optic neuritis. The correlation of increasing optic nerve atrophy with disease duration would be consistent with ongoing axonal loss in a persistently demyelinated lesion, or Wallerian degeneration following axonal damage during the acute inflammatory phase. (orig.)

  3. Measurement of optic tracts in normal Chinese adults of the Han nationality based on the high-resolution MRI

    International Nuclear Information System (INIS)

    Li Changying; Shi Linping; Zhang Yang; Wang Jian; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the morphological characteristics of optic tracts in healthy Chinese Han adults on the high-resolution MRI and fill the database of Chinese standard brain with morphological data of optic tracts. Methods: Cerebral MRI scans with T 1 WI 3D MPRAGE sequence of 1000 healthy Chinese volunteers from 15 hospitals were divided into five stages, ranging in age from 18 to 70. With the technique of multi-baseline, structure and morphology of optic tracts were displayed optimally on the images with multiplanar reconstruction. Data were measured as following: transverse distance of the cisternal optic tract (TD1) and peri-crural optic tract (TD2), length from the cisternal optic tract to the peri-crural optic tract (L), angle between optic tract(AOT) and height of optic tract from its first segment to plane of anterior commissure (H) including H1, H2, H3, H4 and H5. The measurements of optic tracts between sexualities and among age groups were compared by anasis of covariance; those among five age groups were compared pairwisedly by least significant difference analysis (LSD); and the differences of measurements between left and right optic tracts were analyzed using paired t test. Results: (1) Comparisons of optic tract structures between male and female: the mean optic tract length of male [(11.69±1.45),(11.56±1.44) mm] was significant longer than that of female [(10.58±1.29), (10.40±1.34) mm] (F=22.236, 29.703, P=0.000); the mean H1 of male [(2.56±0.28), (2.60±0.29) mm] and female [(2.57±0.31), (2.63±0.32) mm] were significantly different (F= 11.130,7.805, P=0.000, 0.005). No significant differences of the other measurements were found between male and female (P>0.05). (2) Comparisons among age groups: among 5 age groups, TD1 of both sides [left TD1 :(4.64 ± 0.51) ,(4.64 ± 0.57), (4.55 ± 0.58), (4.39 ± 0.53), (4.36 ± 0.58) mm; right TD1: (4.84 ± 0.53), (4.80 ± 0.60 ), (4.77 ± 0.65), (4.60 ± 0.59), (4.57 ± 0.59) mm ] and the right TD2

  4. Method and Apparatus for Creating a Topography at a Surface

    Science.gov (United States)

    Adams, David P.; Sinclair, Michael B.; Mayer, Thomas M.; Vasile, Michael J.; Sweatt, William C.

    2008-11-11

    Methods and apparatus whereby an optical interferometer is utilized to monitor and provide feedback control to an integrated energetic particle column, to create desired topographies, including the depth, shape and/or roughness of features, at a surface of a specimen. Energetic particle columns can direct energetic species including, ions, photons and/or neutral particles to a surface to create features having in-plane dimensions on the order of 1 micron, and a height or depth on the order of 1 nanometer. Energetic processes can include subtractive processes such as sputtering, ablation, focused ion beam milling and, additive processes, such as energetic beam induced chemical vapor deposition. The integration of interferometric methods with processing by energetic species offers the ability to create desired topographies at surfaces, including planar and curved shapes.

  5. Synchrotron topography of grow defects in GdCa4O(BO3)3

    International Nuclear Information System (INIS)

    Wierzbicka, E.; Lefeld-Sosnowska, M.; Wierzchowski, W.; Wieteska, K.; Graeff, W.

    2005-01-01

    Gadolinium calcium oxyborane (GdCOB) is a perspective material, especially in the optoelectronics. GdCOB exhibits excellent nonlinear optical parameters and can be easily doped with Nd 3+ , Yb 3+ or Er 3+ ions. To be applied in the optoelectronics it is necessary to obtain crystals with small number of defects, which cause unwanted tensions changing optical properties of the material. The aim of the work was analysis of the defects distribution in the GdCOB and finding its dependence on the crystal growing conditions. Crystals were grown in the Institute of Electronic Materials Technology (ITME) using Czochralski method. Analyses of the crystal quality are the first studies performed using the synchrotron beam reflection topography in the white beam, monochromatic and projecting transmission topography and the Lang reflections. It has been shown, that the main observed defects are the dislocations, which occur in all crystals of different density depending on the grown parameters [pl

  6. Trabeculectomy and optic nerve head topography

    Directory of Open Access Journals (Sweden)

    A. Paranhos Jr.

    2006-01-01

    Full Text Available The objective of the present study was to evaluate changes in optic nerve head parameters, measured by confocal laser tomography, before and after trabeculectomy in order to identify outcome measures for the management of glaucoma. The optic nerve head of 22 eyes (22 patients was analyzed by confocal laser tomography with the Heidelberg retinal tomogram (HRT before and after trabeculectomy. The median time between the first HRT and surgery was 4.6 months (mean: 7.7 ± 8.3 and the median time between surgery and the second HRT was 10.8 months (mean: 12.0 ± 6.8. The patients were divided into two groups, i.e., those with the highest (group A and lowest (group B intraocular pressure (IOP change after surgery. Differences in the 12 standard topographic parameters before and after surgery for each group were evaluated by the Wilcoxon signed rank test and the differences in these parameters between the two groups were compared by the Mann-Whitney rank sum test. Multiple regression analysis was used to evaluate the influence of the change in IOP (deltaIOP and deltaIOP% and the changes in the other parameters. There were significant differences in the HRT measures before and after surgery in group A only for cup volume. In group B, no parameter was statistically different. The changes in group A were not significantly different than those in group B for any parameter (P > 0.004, Bonferroni correction for multiple comparisons. deltaIOP and deltaIOP% had a statistically significant effect on delta cup disk area, delta cup volume and delta mean cup depth. Changes in cup shape size were influenced significantly only by deltaIOP. Some optic disc parameters measured by HRT presented a significant improvement after filtering surgery, depending on the amount of IOP reduction. Long-term studies are needed to determine the usefulness of these findings as outcome measures in the management of glaucoma.

  7. Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Zikou, Anastasia K.; Tzovara, Ioanna; Margariti, Persefoni; Nikas, Alexios; Asproudis, Ioannis; Blekas, Kostandinos; Galatsanos, Nikolaos

    2007-01-01

    The purpose of the study was to examine the brain and the visual pathway of patients with non-arteritic anterior ischaemic optic neuropathy (NAION) by using conventional MRI (cMRI) and volumetric magnetisation transfer imaging (MTI). Thirty NAION patients, aged 67.5 ± 8.14 years, and 28 age- and gender-matched controls were studied. MTI was used to measure the magnetisation transfer ratio (MTR) of the chiasm and for MTR histograms of the brain. The presence of areas of white matter hyperintensity (WMH) was evaluated on fluid-attenuated inversion recovery (FLAIR) images. Area of the optic nerves (ONs) and volume of the chiasm were assessed, as were coronal short-tau inversion recovery (STIR) and MTI images, respectively. More areas of WMH were observed in patients (total 419; mean 14.4; SD 19) than in controls (total 127; mean 4.7; SD 5.7), P < 0.001. Area (in square millimetres) of the affected ONs, volume(in cubic millimetres) and MTR (in percent) of the chiasm (10.7 ± 4.6), (75.8 ± 20.2), (56.4 ± 6.5), respectively, were lower in patients than in controls (13.6 ± 4.3), (158.2 ± 75.3) (62.1 ± 6.2), respectively, P < 0.05. Mean MTR of brain histograms was lower in patients (53.0 ± 8.0) than in controls (58.0 ± 5.6), P < 0.05. NAION is characterised by decreased ON and chiasmatic size. The low MTR of the chiasm and brain associated with increased areas of WMH may be suggestive of demyelination and axonal damage due to generalised cerebral vascular disease. (orig.)

  8. Development of ballistics identification—from image comparison to topography measurement in surface metrology

    International Nuclear Information System (INIS)

    Song, J; Chu, W; Vorburger, T V; Thompson, R; Renegar, T B; Zheng, A; Yen, J; Silver, R; Ols, M

    2012-01-01

    Fired bullets and ejected cartridge cases have unique ballistics signatures left by the firearm. By analyzing the ballistics signatures, forensic examiners can trace these bullets and cartridge cases to the firearm used in a crime scene. Current automated ballistics identification systems are primarily based on image comparisons using optical microscopy. The correlation accuracy depends on image quality which is largely affected by lighting conditions. Because ballistics signatures are geometrical micro-topographies by nature, direct measurement and correlation of the surface topography is being investigated for ballistics identification. A Two-dimensional and Three-dimensional Topography Measurement and Correlation System was developed at the National Institute of Standards and Technology for certification of Standard Reference Material 2460/2461 bullets and cartridge cases. Based on this system, a prototype system for bullet signature measurement and correlation has been developed for bullet signature identifications, and has demonstrated superior correlation results. (paper)

  9. Gadolinium-DTPA enhanced MRI of the brain

    International Nuclear Information System (INIS)

    Hosten, N.; Felix, R.

    1994-01-01

    The text reviews MRI findings in a variety of cerebral diseases. Advantages of Gadolinium-DTPA (Gd-DTPA) enhanced MRI over plain MRI and enhanced CT are discussed. Enhanced MRI is far superior to enhanced CT in the detection of meningeal tumor spread, meningeal inflammation, inflammatory lesions of the optic nerve, brain lesions in multiple sclerosis and infarction. Enhanced MRI is today the most sensitive diagnostic tool in hypophaseal adenomas. Also enhancement of gliomas is detected by MRI with higher sensitivity than by CT. Use Gd-DTPA allow to separate of vital tumor tissue from necrosis and edema, improve delineation of tumor extension and improve detection of lesions localized in gray matter

  10. Scanning laser topography and scanning laser polarimetry: comparing both imaging methods at same distances from the optic nerve head.

    Science.gov (United States)

    Kremmer, Stephan; Keienburg, Marcus; Anastassiou, Gerasimos; Schallenberg, Maurice; Steuhl, Klaus-Peter; Selbach, J Michael

    2012-01-01

    To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve fiber layer (RNFL). A total of 154 eyes from 5 different groups were examined: young healthy subjects (YNorm), old healthy subjects (ONorm), patients with normal tension glaucoma (NTG), patients with open-angle glaucoma and early glaucomatous damage (OAGE) and patients with open-angle glaucoma and advanced glaucomatous damage (OAGA). SLT and SLP measurements were taken. Four concentric circles were superimposed on each of the images: the first one measuring at the rim of the optic nerve head (1.0 ONHD), the next measuring at 1.25 optic nerve head diameters (ONHD), at 1.5 ONHD and at 1.75 ONHD. The aligned images were analyzed using GDx/NFA software. Both methods showed peaks of RNFL thickness in the superior and inferior segments of the ONH. The maximum thickness, registered by the SLT device was at the ONH rim where the SLP device tended to measure the lowest values. SLT measurements at the ONH were influenced by other tissues besides the RNFL like blood vessels and glial tissues. SLT and SLP were most strongly correlated at distances of 1.25 and 1.5 ONHD. While both imaging technologies are valuable tools in detecting glaucoma, measurements at the ONH rim should be interpreted critically since both methods might provide misleading results. For the assessment of the retinal nerve fiber layer we would like to recommend for both imaging technologies, SLT and SLP, measurements in 1.25 and 1.5 ONHD distance of the rim of the optic nerve head.

  11. Topography-modified refraction: adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    OpenAIRE

    Alpins, Noel

    2017-01-01

    Noel Alpins1,2 1NewVision Clinics, Melbourne, VIC, Australia; 2Department Ophthalmology, Melbourne University, Melbourne, VIC, Australia It is encouraging to see the results in the article by Kanellopoulos “Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK”,1 where the combination of refractive and corneal data in the treatment parameters pro...

  12. OpenTopography: Enabling Online Access to High-Resolution Lidar Topography Data and Processing Tools

    Science.gov (United States)

    Crosby, Christopher; Nandigam, Viswanath; Baru, Chaitan; Arrowsmith, J. Ramon

    2013-04-01

    High-resolution topography data acquired with lidar (light detection and ranging) technology are revolutionizing the way we study the Earth's surface and overlying vegetation. These data, collected from airborne, tripod, or mobile-mounted scanners have emerged as a fundamental tool for research on topics ranging from earthquake hazards to hillslope processes. Lidar data provide a digital representation of the earth's surface at a resolution sufficient to appropriately capture the processes that contribute to landscape evolution. The U.S. National Science Foundation-funded OpenTopography Facility (http://www.opentopography.org) is a web-based system designed to democratize access to earth science-oriented lidar topography data. OpenTopography provides free, online access to lidar data in a number of forms, including the raw point cloud and associated geospatial-processing tools for customized analysis. The point cloud data are co-located with on-demand processing tools to generate digital elevation models, and derived products and visualizations which allow users to quickly access data in a format appropriate for their scientific application. The OpenTopography system is built using a service-oriented architecture (SOA) that leverages cyberinfrastructure resources at the San Diego Supercomputer Center at the University of California San Diego to allow users, regardless of expertise level, to access these massive lidar datasets and derived products for use in research and teaching. OpenTopography hosts over 500 billion lidar returns covering 85,000 km2. These data are all in the public domain and are provided by a variety of partners under joint agreements and memoranda of understanding with OpenTopography. Partners include national facilities such as the NSF-funded National Center for Airborne Lidar Mapping (NCALM), as well as non-governmental organizations and local, state, and federal agencies. OpenTopography has become a hub for high-resolution topography

  13. Optic Nerve Assessment Using 7-Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Singh, Arun D; Platt, Sean M; Lystad, Lisa; Lowe, Mark; Oh, Sehong; Jones, Stephen E; Alzahrani, Yahya; Plesec, Thomas

    2016-04-01

    The purpose of this study was to correlate high-resolution magnetic resonance imaging (MRI) and histologic findings in a case of juxtapapillary choroidal melanoma with clinical evidence of optic nerve invasion. With institutional review board approval, an enucleated globe with choroidal melanoma and optic nerve invasion was imaged using a 7-tesla MRI followed by histopathologic evaluation. Optical coherence tomography, B-scan ultrasonography, and 1.5-tesla MRI of the orbit (1-mm sections) could not detect optic disc invasion. Ex vivo, 7-tesla MRI detected optic nerve invasion, which correlated with histopathologic features. Our case demonstrates the potential to document the existence of optic nerve invasion in the presence of an intraocular tumor, a feature that has a major bearing on decision making, particularly for consideration of enucleation.

  14. Hippocampal neurons respond uniquely to topographies of various sizes and shapes

    International Nuclear Information System (INIS)

    Fozdar, David Y; Chen Shaochen; Lee, Jae Young; Schmidt, Christine E

    2010-01-01

    A number of studies have investigated the behavior of neurons on microfabricated topography for the purpose of developing interfaces for use in neural engineering applications. However, there have been few studies simultaneously exploring the effects of topographies having various feature sizes and shapes on axon growth and polarization in the first 24 h. Accordingly, here we investigated the effects of arrays of lines (ridge grooves) and holes of microscale (∼2 μm) and nanoscale (∼300 nm) dimensions, patterned in quartz (SiO 2 ), on the (1) adhesion, (2) axon establishment (polarization), (3) axon length, (4) axon alignment and (5) cell morphology of rat embryonic hippocampal neurons, to study the response of the neurons to feature dimension and geometry. Neurons were analyzed using optical and scanning electron microscopy. The topographies were found to have a negligible effect on cell attachment but to cause a marked increase in axon polarization, occurring more frequently on sub-microscale features than on microscale features. Neurons were observed to form longer axons on lines than on holes and smooth surfaces; axons were either aligned parallel or perpendicular to the line features. An analysis of cell morphology indicated that the surface features impacted the morphologies of the soma, axon and growth cone. The results suggest that incorporating microscale and sub-microscale topographies on biomaterial surfaces may enhance the biomaterials' ability to modulate nerve development and regeneration.

  15. A noncontact laser system for measuring soil surface topography

    International Nuclear Information System (INIS)

    Huang, C.; White, I.; Thwaite, E.G.; Bendeli, A.

    1988-01-01

    Soil surface topography profoundly influences runoff hydrodynamics, soil erosion, and surface retention of water. Here we describe an optical noncontact system for measuring soil surface topography. Soil elevation is measured by projecting a laser beam onto the surface and detecting the position of the interception point. The optical axis of the detection system is oriented at a small angle to the incident beam. A low-power HeNe (Helium-Neon) laser is used as the laser source, a photodiode array is used as the laser image detector and an ordinary 35-mm single lens reflex camera provides the optical system to focus the laser image onto the diode array. A wide spectrum of measurement ranges (R) and resolutions are selectable, from 1 mm to 1 m. These are determined by the laser-camera distance and angle, the focal length of the lens, and the sensing length of the diode array and the number of elements (N) contained in the array. The resolution of the system is approximately R/2N. We show for the system used here that this resolution is approximately 0.2%. In the configuration selected, elevation changes of 0.16 mm could be detected over a surface elevation range of 87 mm. The sampling rate of the system is 1000 Hz, which permits soil surfaces to be measured at speeds of up to 1 m s −1 with measurements taken at 1-mm spacing. Measurements of individual raindrop impacts on the soil and of soil surfaces before and after rain show the versatility of the laser surface profiler, which has applications in studies of erosion processes, surface storage and soil trafficability

  16. Endophthalmitis after descemet stripping endothelial keratoplasty with concave-oriented dislocation on slit-lamp optical coherence topography.

    Science.gov (United States)

    Kaiura, Terry L; Ritterband, David C; Koplin, Richard S; Shih, Carolyn; Palmierto, Pat M; Seedor, John A

    2010-02-01

    To present the first reported case of Descemet membrane stripping endothelial keratoplasty (DSEK)-associated endophthalmitis with concave dislocation on slit-lamp optical coherence topography (SL-OCT). An 86-year-old man underwent DSEK for corneal decompensation secondary to prior surgery. On all postoperative visits, a slit-lamp examination and SL-OCT were performed. On the first postoperative day, the lenticle was dislocated in a concave configuration as imaged with the SL-OCT. On the second postoperative day, the patient had eye pain, nausea, and increased intraocular pressure. On SL-OCT imaging, the concave configuration and fibrin stranding were imaged. With intraocular pressure lowering, the patient's pain subsided, and he was scheduled for a lenticle refloat the following day. The next day, endophthalmitis was diagnosed secondary to exuberant purulent inflammation. At surgery, the lenticle was removed, cultures were obtained, and pars plana vitrectomy and intravitreal injections were administered. Intraoperative cultures were positive for heavy growth of Streptococcus pneumoniae. Endophthalmitis is a potential complication for any intraocular procedure including DSEK. SL-OCT imaging postoperatively may reveal concave lenticle configuration and subtle anterior chamber fibrin stranding may be early sign of endophthalmitis.

  17. MRI characteristics of neuromyelitis optica spectrum disorder

    Science.gov (United States)

    Paul, Friedemann; Lana-Peixoto, Marco A.; Tenembaum, Silvia; Asgari, Nasrin; Palace, Jacqueline; Klawiter, Eric C.; Sato, Douglas K.; de Seze, Jérôme; Wuerfel, Jens; Banwell, Brenda L.; Villoslada, Pablo; Saiz, Albert; Fujihara, Kazuo; Kim, Su-Hyun

    2015-01-01

    Since its initial reports in the 19th century, neuromyelitis optica (NMO) had been thought to involve only the optic nerves and spinal cord. However, the discovery of highly specific anti–aquaporin-4 antibody diagnostic biomarker for NMO enabled recognition of more diverse clinical spectrum of manifestations. Brain MRI abnormalities in patients seropositive for anti–aquaporin-4 antibody are common and some may be relatively unique by virtue of localization and configuration. Some seropositive patients present with brain involvement during their first attack and/or continue to relapse in the same location without optic nerve and spinal cord involvement. Thus, characteristics of brain abnormalities in such patients have become of increased interest. In this regard, MRI has an increasingly important role in the differential diagnosis of NMO and its spectrum disorder (NMOSD), particularly from multiple sclerosis. Differentiating these conditions is of prime importance because early initiation of effective immunosuppressive therapy is the key to preventing attack-related disability in NMOSD, whereas some disease-modifying drugs for multiple sclerosis may exacerbate the disease. Therefore, identifying the MRI features suggestive of NMOSD has diagnostic and prognostic implications. We herein review the brain, optic nerve, and spinal cord MRI findings of NMOSD. PMID:25695963

  18. Size of the intracranial optic nerve and optic tract in neonates at term-equivalent age at magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Jun; Mori, Kouichi [Tsuchiura Kyodo General Hospital, Department of Radiology, Tsuchiura, Ibaraki (Japan); Imamura, Masatoshi [Tsuchiura Kyodo General Hospital, Department of Neonatology, Tsuchiura, Ibaraki (Japan); Mizushima, Yukiko [Tsuchiura Kyodo General Hospital, Department of Ophthalmology, Tsuchiura, Ibaraki (Japan); Tateishi, Ukihide [Tokyo Medical and Dental University, Departments of Diagnostic Radiology and Nuclear Medicine, Tokyo (Japan)

    2016-04-15

    The expected MRI-based dimensions of the intracranial optic nerve and optic tract in neonates are unknown. To evaluate the sizes of the intracranial optic nerve and optic tract in neonates at term-equivalent age using MRI. We retrospectively analyzed brain MRI examinations in 62 infants (28 boys) without intracranial abnormalities. The images were obtained in infants at term-equivalent age with a 1.5-tesla MRI scanner. We measured the widths and heights of the intracranial optic nerve and optic tract and calculated the cross-sectional areas using the formula for an ellipse. The means ± standard deviation of the width, height and cross-sectional area of the intracranial optic nerve were 2.7 ± 0.2 mm, 1.7 ± 0.2 mm and 3.5 ± 0.5 mm{sup 2}, respectively. The width, height and cross-sectional area of the optic tract were 1.5 ± 0.1 mm, 1.6 ± 0.1 mm and 2.0 ± 0.2 mm{sup 2}, respectively. Using univariate and multivariate analyses, we found that postmenstrual age showed independent intermediate positive correlations with the width (r = 0.48, P < 0.01) and cross-sectional area (r = 0.40, P < 0.01) of the intracranial optic nerve. The lower bounds of the 95% prediction intervals for the width and cross-sectional area of the intracranial optic nerve were 0.07 x (postmenstrual age in weeks) - 0.46 mm, and 0.17 x (postmenstrual age in weeks) - 4.0 mm{sup 2}, respectively. We identified the sizes of the intracranial optic nerve and optic tract in neonates at term-equivalent age. The postmenstrual age at MRI independently positively correlated with the sizes. (orig.)

  19. Apoptosis study of the macrophage via near-field scanning optical microscope

    International Nuclear Information System (INIS)

    Wang, D-C; Chen, K-Y; Chen, G-Y; Chen, S-H; Wun, S-J

    2008-01-01

    The cell apoptosis phenomenon was studied by traditional optical microscope with much lower resolution and also observed by Atomic Force Microscope (AFM) with nano-resolution recently. They both detect the cell apoptosis through the change of cell topography. In this study, the cell apoptosis was investigated via Near-Field Scanning Optical Microscope (NSOM). The cell topography, with nano-scaled resolution, and its optical characteristics were observed by NSOM at the same measurement scanning. The macrophage was chosen as the cell investigated. To understand the cell apoptosis process is the goal set for the research. The apoptosis process was related to the variations of the optical characteristics of the cell

  20. The value of MRI of the thorax in congenital stenosis of the trachea

    International Nuclear Information System (INIS)

    Vogl, T.; Wilimzig, C.; Lissner, J.; Hofmann, U.; Hofmann, D.; Hecker, W.

    1989-01-01

    MRI of the thorax was performed in 24 children aged between six weeks and five years, in whom a tracheal stenosis had been demonstrated by bronchoscopy. Since bronchoscopy can only demonstrate the interior of the trachea, various imaging methods, such as CT and angiography, were used to demonstrate the topography and cause of the tracheal stenosis. MRI has shown that the most common cause of a stenosis in the central section of the trachea is focal compression by an aberrant bracheocephalic trunk (10 cases). Stenosis of the distal trachea could be due to anomalies of the aortic arch (5 cases), a dilated pulmonary artery (4 cases) or a soft tissue mass (3 cases). In all these patients, MRI was greatly superior to the conventional methods. By using a special technique, MRI made it possible to clarify the cause and localisation of a tracheal stenosis by a non-invasive examination. (orig.) [de

  1. In Vivo Evaluation of the Visual Pathway in Streptozotocin-Induced Diabetes by Diffusion Tensor MRI and Contrast Enhanced MRI.

    Directory of Open Access Journals (Sweden)

    Swarupa Kancherla

    Full Text Available Visual function has been shown to deteriorate prior to the onset of retinopathy in some diabetic patients and experimental animal models. This suggests the involvement of the brain's visual system in the early stages of diabetes. In this study, we tested this hypothesis by examining the integrity of the visual pathway in a diabetic rat model using in vivo multi-modal magnetic resonance imaging (MRI. Ten-week-old Sprague-Dawley rats were divided into an experimental diabetic group by intraperitoneal injection of 65 mg/kg streptozotocin in 0.01 M citric acid, and a sham control group by intraperitoneal injection of citric acid only. One month later, diffusion tensor MRI (DTI was performed to examine the white matter integrity in the brain, followed by chromium-enhanced MRI of retinal integrity and manganese-enhanced MRI of anterograde manganese transport along the visual pathway. Prior to MRI experiments, the streptozotocin-induced diabetic rats showed significantly smaller weight gain and higher blood glucose level than the control rats. DTI revealed significantly lower fractional anisotropy and higher radial diffusivity in the prechiasmatic optic nerve of the diabetic rats compared to the control rats. No apparent difference was observed in the axial diffusivity of the optic nerve, the chromium enhancement in the retina, or the manganese enhancement in the lateral geniculate nucleus and superior colliculus between groups. Our results suggest that streptozotocin-induced diabetes leads to early injury in the optic nerve when no substantial change in retinal integrity or anterograde transport along the visual pathways was observed in MRI using contrast agent enhancement. DTI may be a useful tool for detecting and monitoring early pathophysiological changes in the visual system of experimental diabetes non-invasively.

  2. High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance.

    Science.gov (United States)

    Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H

    2011-12-01

    We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Characterization of the optical grade synthetic quartz by X-ray topography; Caracterizacao de quartzo sintetico de grau optico por topografia de raios-X

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Marcos S; Suzuki, Carlos K; Iwasaki, Fumiko [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica

    1996-09-01

    The first initiative to develop a technology to grow the optical grade synthetic quartz in our country has been conducted by the UNICAMP - JICA - ABC Crystals collaboration. This research shows that the solid inclusions concentrations is practically inexistent, less than 0.03 incl/cm{sup 3}, what satisfy the international standard requirements. On the other hand, the characterization studies by X-ray topography enabled us to estimate the dislocation line density of order of 1200 lines/cm{sup 2}. This value is higher than to the usual international standard requirements. From this study, we obtained a full knowledge of defects origin, where the optimization process could be done by using seeds with superior quality. (author) 16 refs., 4 figs., 1 tab.

  4. MRI in acute disseminated encephalomyelitis

    International Nuclear Information System (INIS)

    Caldemeyer, K.S.; Smith, R.R.; Harris, T.M.; Edwards, M.K.

    1994-01-01

    A retrospective analysis of CT and MRI studies in 12 patients with a clinical diagnosis of acute disseminated encephalomyelitis (ADEM) was performed. MRI was the definitive modality for the assessment of the lesions of ADEM: all patients had abnormalities consistent with the clinical diagnosis. Ten had abnormalities in the brain, three spinal cord lesions, and three showed evidence of optic neuritis. CT was normal in 6 of the 7 patients in which it was performed. (orig.)

  5. Evaluating contextual processing in diffusion MRI: application to optic radiation reconstruction for epilepsy surgery.

    Directory of Open Access Journals (Sweden)

    Chantal M W Tax

    Full Text Available Diffusion MRI and tractography allow for investigation of the architectural configuration of white matter in vivo, offering new avenues for applications like presurgical planning. Despite the promising outlook, there are many pitfalls that complicate its use for (clinical application. Amongst these are inaccuracies in the geometry of the diffusion profiles on which tractography is based, and poor alignment with neighboring profiles. Recently developed contextual processing techniques, including enhancement and well-posed geometric sharpening, have shown to result in sharper and better aligned diffusion profiles. However, the research that has been conducted up to now is mainly of theoretical nature, and so far these techniques have only been evaluated by visual inspection of the diffusion profiles. In this work, the method is evaluated in a clinically relevant application: the reconstruction of the optic radiation for epilepsy surgery. For this evaluation we have developed a framework in which we incorporate a novel scoring procedure for individual pathways. We demonstrate that, using enhancement and sharpening, the extraction of an anatomically plausible reconstruction of the optic radiation from a large amount of probabilistic pathways is greatly improved in three healthy controls, where currently used methods fail to do so. Furthermore, challenging reconstructions of the optic radiation in three epilepsy surgery candidates with extensive brain lesions demonstrate that it is beneficial to integrate these methods in surgical planning.

  6. On-machine measurement of the grinding wheels' 3D surface topography using a laser displacement sensor

    Science.gov (United States)

    Pan, Yongcheng; Zhao, Qingliang; Guo, Bing

    2014-08-01

    A method of non-contact, on-machine measurement of three dimensional surface topography of grinding wheels' whole surface was developed in this paper, focusing on an electroplated coarse-grained diamond grinding wheel. The measuring system consists of a Keyence laser displacement sensor, a Keyence controller and a NI PCI-6132 data acquisition card. A resolution of 0.1μm in vertical direction and 8μm in horizontal direction could be achieved. After processing the data by LabVIEW and MATLAB, the 3D topography of the grinding wheel's whole surface could be reconstructed. When comparing the reconstructed 3D topography of the grinding wheel's marked area to its real topography captured by a high-depth-field optical digital microscope (HDF-ODM) and scanning electron microscope (SEM), they were very similar to each other, proving that this method is accurate and effective. By a subsequent data processing, the topography of every grain could be extracted and then the active grain number, the active grain volume and the active grain's bearing ration could be calculated. These three parameters could serve as the criterion to evaluate the grinding performance of coarse-grained diamond grinding wheels. Then the performance of the grinding wheel could be evaluated on-machine accurately and quantitatively.

  7. Comparing three-dimensional serial optical coherence tomography histology to MRI imaging in the entire mouse brain

    Science.gov (United States)

    Castonguay, Alexandre; Lefebvre, Joël; Pouliot, Philippe; Lesage, Frédéric

    2018-01-01

    An automated serial histology setup combining optical coherence tomography (OCT) imaging with vibratome sectioning was used to image eight wild type mouse brains. The datasets resulted in thousands of volumetric tiles resolved at a voxel size of (4.9×4.9×6.5) μm3 stitched back together to give a three-dimensional map of the brain from which a template OCT brain was obtained. To assess deformation caused by tissue sectioning, reconstruction algorithms, and fixation, OCT datasets were compared to both in vivo and ex vivo magnetic resonance imaging (MRI) imaging. The OCT brain template yielded a highly detailed map of the brain structure, with a high contrast in white matter fiber bundles and was highly resemblant to the in vivo MRI template. Brain labeling using the Allen brain framework showed little variation in regional brain volume among imaging modalities with no statistical differences. The high correspondence between the OCT template brain and its in vivo counterpart demonstrates the potential of whole brain histology to validate in vivo imaging.

  8. AFM topographies of densely packed nanoparticles: a quick way to determine the lateral size distribution by autocorrelation function analysis

    International Nuclear Information System (INIS)

    Fekete, L.; Kůsová, K.; Petrák, V.; Kratochvílová, I.

    2012-01-01

    The distribution of sizes is one of the basic characteristics of nanoparticles. Here, we propose a novel way to determine the lateral distribution of sizes from AFM topographies. Our algorithm is based on the autocorrelation function and can be applied both on topographies containing spatially separated and densely packed nanoparticles as well as on topographies of polycrystalline films. As no manual treatment is required, this algorithm can be easily automatable for batch processing. The algorithm works in principle with any kind of spatially mapped information (AFM current maps, optical microscope images, etc.), and as such has no size limitations. However, in the case of AFM topographies, the tip/sample convolution effects will be the factor limiting the smallest size to which the algorithm is applicable. Here, we demonstrate the usefulness of this algorithm on objects with sizes ranging between 20 nm and 1.5 μm.

  9. Investigation of CT and MRI findings of cranio-orbital communicating lesions

    International Nuclear Information System (INIS)

    Wang Zhenchang; Jiang Dingyao; Xian Junfang; An Yuzhi; Zhang Tianming; Li Bin; Liang Xihong; Yang Bentao

    2001-01-01

    Objective: To investigate CT and MRI findings of cranio-orbital communicating lesions so as to find out communicating passages and their imaging features. Methods: Fifty-one cases of cranio-orbital communicating lesions confirmed by pathology and follow-up results were studied. CT was performed in all cases and MRI in 45 cases. Post-contrast CT and MRI was completed in 44 cases. Results: There were 31 cases (60.8%) with lesions communicating between the orbital cavity and the cranial cavity through optic canal or superior orbital fissure showing communicating soft tissue mass and enlargement of optic canal or superior orbital fissure. Four cases of optic gliomas involving optic nerve and optic chiasm, three cases with meningiomas of optic nerve sheath, and 2 cases with retinoblastoma involving optic nerve and optic chiasm showed cranio-orbital communicating masses through the optic canal. Cranio-orbital communicating mass with enlargement of superior orbital fissure was found in 22 patients including 5 meningiomas, 4 neurogenic tumors, 1 dermoid cyst, 3 inflammatory pseudotumors, 2 Tolosa-Hunt syndromes and 7 metastases from nasopharyngeal carcinoma. In addition, 20 of 51 cases (39.2%) communicated through perforating blood vessels or bony defect resulted from tumor destruction. Of these lesions, there were 10 metastases showing bone destruction in orbital walls, 5 cases with en plaque meningiomas of sphenoid bone with marked hyperostosis and widespread dural involvement, 1 chondrosarcoma involving frontal lobe and orbit, 3 adenoid cystic carcinomas involving frontal lobe, and 1 malignant meningioma with bone destruction of the superior orbital wall. Conclusion: CT and MRI could definitely demonstrate communicating passages of cranio-orbital communicating lesions and their imaging changes, which could contribute to diagnosis and differential diagnosis and provide valuable information for determining treatment measures and surgical approach

  10. Measuring topographies from conventional SEM acquisitions.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-04-27

    The present study extends the stereoscopic imaging principle for estimating the surface topography to two orientations, namely, normal to the electron beam axis and inclined at 70° as suited for EBSD analyses. In spite of the large angle difference, it is shown that the topography can be accurately determined using regularized global Digital Image Correlation. The surface topography is compared to another estimate issued from a 3D FIB-SEM procedure where the sample surface is first covered by a Pt layer, and its initial topography is progressively revealed from successive FIB-milling. These two methods are successfully compared on a 6% strained steel specimen in an in situ mechanical test. This analysis is supplemented by a third approach estimating the change of topography from crystal rotations as measured from successive EBSD images. This last technique ignores plastic deformation, and thus only holds in an elastic regime. For the studied example, despite the large plastic flow, it is shown that crystal rotation already accounts for a significant part of the deformation-induced topography. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. 3D surface topography study of the biofunctionalized nanocrystalline Ti–6Zr–4Nb/Ca–P

    International Nuclear Information System (INIS)

    Jakubowicz, J.; Adamek, G.; Jurczyk, M.U.; Jurczyk, M.

    2012-01-01

    In this work surface of the sintered Ti–6Zr–4Nb nanocrystalline alloy was electrochemically biofunctionalized. The porous surface was produced by anodic oxidation in 1 M H 3 PO 4 + 2%HF electrolyte at 10 V for 30 min. Next the calcium–phosphate (Ca–P) layer was deposited, onto the formed porous surface, using cathodic potential − 5 V kept for 60 min in 0.042 M Ca(NO 3 ) 2 + 0.025 M (NH 4 ) 2 HPO 4 + 0.1 M HCl electrolyte. The deposited Ca–P layer anchored in the pores. The biofunctionalized surface was studied by XRD, SEM and EDS. In vitro tests culture of normal human osteoblast (NHOst) cells showed very good cells proliferation, colonization and multilayering. Using optical profiler, roughness and hybrid 3D surface topography parameters were estimated. Correlation between surface composition, morphology, roughness and biocompatibility results was done. It has been shown by us that surface with appropriate chemical composition and topography, after combined electrochemical anodic and cathodic surface treatment, supports osteoblast adhesion and proliferation. 3D topography measurements using optical profiler play a key role in the biomaterials surface analysis. - Highlights: ► Nanocrystalline Ti–6Zr–4Nb/Ca–P material was produced for hard tissue implant applications. ► Calcium-phosphate results in surface biofunctionalization. ► The biofunctionalized surface shows good in-vitro behavior.

  12. Growth and surface topography of WSe_2 single crystal

    International Nuclear Information System (INIS)

    Dixit, Vijay; Vyas, Chirag; Pataniya, Pratik; Jani, Mihir; Pathak, Vishal; Patel, Abhishek; Pathak, V. M.; Patel, K. D.; Solanki, G. K.

    2016-01-01

    Tungsten Di-Selenide belongs to the family of TMDCs showing their potential applications in the fields of Optoelectronics and PEC solar cells. Here in the present investigation single crystals of WSe_2 were grown by Direct Vapour Transport Technique in a dual zone furnace having temperature difference of 50 K between the two zones. These single crystals were characterized by EDAX which confirms the stiochiometry of the grown crystals. Surface topography of the crystal was studied by optical micrograph showing the left handed spirals on the surface of WSe_2 crystals. Single crystalline nature of the crystals was confirmed by SAED.

  13. MRI of Wolfram syndrome (DIDMOAD)

    Energy Technology Data Exchange (ETDEWEB)

    Galluzzi, P.; Filosomi, G.; Vallone, I.M.; Venturi, C. [Dept. of Neuroradiology, Policlinico ' ' Le Scotte' ' , Siena (Italy); Bardelli, A.M. [Dept. of Ophthalmological Sciences, Unit of Paediatric Ophthalmology, University of Siena (Italy)

    1999-10-01

    Wolfram syndrome (DIDMOAD) is a rare diffuse neurodegenerative disorder characterised by diabetes insipidus, diabetes mellitus, optic atrophy, deafness, and a wide variety of abnormalities of the central nervous system, urinary tract and endocrine glands. It may be familial or sporadic. Reported features on MRI of the brain are absence of the physiological high signal of the posterior lobe of the pituitary, shrinkage of optic nerves, chiasm and tracts, atrophy of the hypothalamic region, brain stem, cerebellum, and cerebral cortex. We report a 12-year-old girl with a 5-year history without brain stem, cerebellar or cerebral atrophy. MRI showed an unusual feature: a focus of high signal on PD- and T2-weighted images in the right substantia nigra. This is consistent with previously reported neuropathological post-mortem studies, but has never been reported in vivo. (orig.)

  14. MRI of Wolfram syndrome (DIDMOAD)

    International Nuclear Information System (INIS)

    Galluzzi, P.; Filosomi, G.; Vallone, I.M.; Venturi, C.; Bardelli, A.M.

    1999-01-01

    Wolfram syndrome (DIDMOAD) is a rare diffuse neurodegenerative disorder characterised by diabetes insipidus, diabetes mellitus, optic atrophy, deafness, and a wide variety of abnormalities of the central nervous system, urinary tract and endocrine glands. It may be familial or sporadic. Reported features on MRI of the brain are absence of the physiological high signal of the posterior lobe of the pituitary, shrinkage of optic nerves, chiasm and tracts, atrophy of the hypothalamic region, brain stem, cerebellum, and cerebral cortex. We report a 12-year-old girl with a 5-year history without brain stem, cerebellar or cerebral atrophy. MRI showed an unusual feature: a focus of high signal on PD- and T2-weighted images in the right substantia nigra. This is consistent with previously reported neuropathological post-mortem studies, but has never been reported in vivo. (orig.)

  15. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  16. Magnetic resonance imaging of optic nerve

    International Nuclear Information System (INIS)

    Gala, Foram

    2015-01-01

    Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI), plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies

  17. Unusual MRI findings in grey matter heteropia

    International Nuclear Information System (INIS)

    Soto Ares, G.; Hamon-Kerautret, M.; Leclerc, X.; Pruvo, J.P.; Houlette, C.; Godefroy, O.

    1998-01-01

    We report unusual MRI patterns in patients with grey matter heterotopia. Standard T1- and T2-weighted spin-echo and inversion-recovery sequences were used in 22 patients presenting with seizures or developmental delay. The images were reviewed for signal change surrounding white matter and for atypical size, morphology or topography. We found 10 cases of subependymal heterotopias 11 of focal subcortical heterotopia and of diffuse subcortical heterotopia. On clinical or MRI grounds, 8 cases were considered unusual: 2 of the subependymal type, 2 of focal subcortical heterotopia with white matter abnormalities, 2 of focal subcortical heterotopia with no clinicoradiological correlation 1 of extensive hemispheric subcortical heterotopia and 1 of diffuse subcortical heterotopia confined to the frontal lobe. The classical classification of heterotopia enables easy radiological diagnosis even in cases with unusual patterns. In some cases, heterogeneity and high signal in surrounding white matter can be found. Cortical dysplasia is the most frequent associated malformation. (orig.)

  18. Topography Grid

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NGDC builds and distributes high-resolution, coastal digital elevation models (DEMs) that integrate ocean bathymetry and land topography to support NOAA's mission to...

  19. Three-way ROC validation of rs-fMRI visual information propagation transfer functions used to differentiate between RRMS and CIS optic neuritis patients.

    Science.gov (United States)

    Farahani, Ehsan Shahrabi; Choudhury, Samiul H; Cortese, Filomeno; Costello, Fiona; Goodyear, Bradley; Smith, Michael R

    2017-07-01

    Resting-state fMRI (rs-fMRI) measures the temporal synchrony between different brain regions while the subject is at rest. We present an investigation using visual information propagation transfer functions as potential optic neuritis (ON) markers for the pathways between the lateral geniculate nuclei, the primary visual cortex, the lateral occipital cortex and the superior parietal cortex. We investigate marker reliability in differentiating between healthy controls and ON patients with clinically isolated syndrome (CIS), and relapsing-remitting multiple sclerosis (RRMS) using a three-way receiver operating characteristics analysis. We identify useful and reliable three-way ON related metrics in the rs-fMRI low-frequency band 0.0 Hz to 0.1 Hz, with potential markers associated with the higher frequency harmonics of these signals in the 0.1 Hz to 0.2 Hz and 0.2 Hz to 0.3 Hz bands.

  20. Magnetic resonance imaging in optic nerve lesions with multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo; Kakisu, Yonetsugu; Adachi, Emiko

    1990-01-01

    Magnetic resonance imaging (MRI) of the optic nerve was performed in 10 patients with multiple sclerosis (MS) using short inversion time inversion recovery (STIR) pulse sequences, and the results were compared with the visual evoked potentials (VEP). The 10 patients had optic neuritis in the chronic or remitting phase together with additional symptoms or signs allowing a diagnosis of clinically definite or probable MS. Sixteen optic nerves were clinically affected and 4 were unaffected. MRI was performed using a 0.5 tesla supeconducting unit, and multiple continuous 5 mm coronal and axial STIR images were obtained. A lesion was judged to be present if a focal or diffuse area of increased signal intensity was detectd in the optic nerve. In VEP, a delay in peak latency or no P 100 component was judged to be abnormal. With regard to the clinically affected optic nerves, MRI revealed a region of increased signal intensity in 14/16 (88%) and the VEP was abnormal in 16/16 (100%). In the clinically unaffected optic nerves, MRI revealed an increased signal intensity in 2/4 (50%). One of these nerves had an abnormal VEP and the other had a VEP latency at the upper limit of normal. The VEP was abnormal in 1/4 (25%). In the clinically affected optic nerves, the degree of loss of visual acuity was not associated with the longitudinal extent of the lesions shown by MRI. The mean length was 17.5 mm in optic nerves with a slight disturbance of visual acuity and 15.0 mm in nerves with severe visual loss. MRI using STIR pulse sequences was found to be almost as sensitive as VEP in detecting both clinically affected and unaffected optic nerve lesions in patients with MS, and was useful in visualizing the location or size of the lesions. (author)

  1. Background research in support of the new grant proposal: Research consortium for X-ray topography on line X-19 at NSLS

    Science.gov (United States)

    Bilello, J. C.

    1983-11-01

    The status of the construction and installation of components of the synchrotron topography station is reported as well as progress in the development of hardware for interfacing and software for interactively controlling the 13 motors which automate the facility. Research focuses on the problem of X-ray optics and on techniques for applying topography to materials science. There is colaboration with other researchers in studying the nature of brittle fracture of refractory metals and in interpreting contact in the vicinity of crack tips.

  2. Surface Micro Topography Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2005-01-01

    The surface micro topography of injection moulded plastic parts can be important for aesthetical and technical reasons. The quality of replication of mould surface topography onto the plastic surface depends among other factors on the process conditions. A study of this relationship has been...... carried out with rough EDM (electrical discharge machining) mould surfaces, a PS grade, and by applying established three-dimensional topography parameters. Significant quantitative relationships between process parameters and topography parameters were established. It further appeared that replication...

  3. Surface Topography Hinders Bacterial Surface Motility.

    Science.gov (United States)

    Chang, Yow-Ren; Weeks, Eric R; Ducker, William A

    2018-03-21

    We demonstrate that the surface motility of the bacterium, Pseudomonas aeruginosa, is hindered by a crystalline hemispherical topography with wavelength in the range of 2-8 μm. The motility was determined by the analysis of time-lapse microscopy images of cells in a flowing growth medium maintained at 37 °C. The net displacement of bacteria over 5 min is much lower on surfaces containing 2-8 μm hemispheres than on flat topography, but displacement on the 1 μm hemispheres is not lower. That is, there is a threshold between 1 and 2 μm for response to the topography. Cells on the 4 μm hemispheres were more likely to travel parallel to the local crystal axis than in other directions. Cells on the 8 μm topography were less likely to travel across the crowns of the hemispheres and were also more likely to make 30°-50° turns than on flat surfaces. These results show that surface topography can act as a significant barrier to surface motility and may therefore hinder surface exploration by bacteria. Because surface exploration can be a part of the process whereby bacteria form colonies and seek nutrients, these results help to elucidate the mechanism by which surface topography hinders biofilm formation.

  4. Concurrent tACS-fMRI Reveals Causal Influence of Power Synchronized Neural Activity on Resting State fMRI Connectivity.

    Science.gov (United States)

    Bächinger, Marc; Zerbi, Valerio; Moisa, Marius; Polania, Rafael; Liu, Quanying; Mantini, Dante; Ruff, Christian; Wenderoth, Nicole

    2017-05-03

    Resting state fMRI (rs-fMRI) is commonly used to study the brain's intrinsic neural coupling, which reveals specific spatiotemporal patterns in the form of resting state networks (RSNs). It has been hypothesized that slow rs-fMRI oscillations (5 Hz); however, causal evidence for this relationship is currently lacking. Here we measured rs-fMRI in humans while applying transcranial alternating current stimulation (tACS) to entrain brain rhythms in left and right sensorimotor cortices. The two driving tACS signals were tailored to the individual's α rhythm (8-12 Hz) and fluctuated in amplitude according to a 1 Hz power envelope. We entrained the left versus right hemisphere in accordance to two different coupling modes where either α oscillations were synchronized between hemispheres (phase-synchronized tACS) or the slower oscillating power envelopes (power-synchronized tACS). Power-synchronized tACS significantly increased rs-fMRI connectivity within the stimulated RSN compared with phase-synchronized or no tACS. This effect outlasted the stimulation period and tended to be more effective in individuals who exhibited a naturally weak interhemispheric coupling. Using this novel approach, our data provide causal evidence that synchronized power fluctuations contribute to the formation of fMRI-based RSNs. Moreover, our findings demonstrate that the brain's intrinsic coupling at rest can be selectively modulated by choosing appropriate tACS signals, which could lead to new interventions for patients with altered rs-fMRI connectivity. SIGNIFICANCE STATEMENT Resting state fMRI (rs-fMRI) has become an important tool to estimate brain connectivity. However, relatively little is known about how slow hemodynamic oscillations measured with fMRI relate to electrophysiological processes. It was suggested that slowly fluctuating power envelopes of electrophysiological signals synchronize across brain areas and that the topography of this activity is spatially correlated to

  5. A new method for the assessment of the surface topography of NiTi rotary instruments.

    Science.gov (United States)

    Ferreira, F; Barbosa, I; Scelza, P; Russano, D; Neff, J; Montagnana, M; Zaccaro Scelza, M

    2017-09-01

    To describe a new method for the assessment of nanoscale alterations in the surface topography of nickel-titanium endodontic instruments using a high-resolution optical method and to verify the accuracy of the technique. Noncontact three-dimensional optical profilometry was used to evaluate defects on a size 25, .08 taper reciprocating instrument (WaveOne ® ), which was subjected to a cyclic fatigue test in a simulated root canal in a clear resin block. For the investigation, an original procedure was established for the analysis of similar areas located 3 mm from the tip of the instrument before and after canal preparation to enable the repeatability and reproducibility of the measurements with precision. All observations and analysis were taken in areas measuring 210 × 210 μm provided by the software of the equipment. The three-dimensional high-resolution image analysis showed clear alterations in the surface topography of the examined cutting blade and flute of the instrument, before and after use, with the presence of surface irregularities such as deformations, debris, grooves, cracks, steps and microcavities. Optical profilometry provided accurate qualitative nanoscale evaluation of similar surfaces before and after the fatigue test. The stability and repeatability of the technique enables a more comprehensive understanding of the effects of wear on the surface of endodontic instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  6. Shallow flows with bottom topography

    NARCIS (Netherlands)

    Heijst, van G.J.F.; Kamp, L.P.J.; Theunissen, R.; Rodi, W.; Uhlmann, M.

    2012-01-01

    This paper discusses laboratory experiments and numerical simulations of dipolar vortex flows in a shallow fluid layer with bottom topography. Two cases are considered: a step topography and a linearly sloping bottom. It is found that viscous effects – i.e., no-slip conditions at the non-horizontal

  7. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  8. Brucellosis of the pituitary region: MRI

    International Nuclear Information System (INIS)

    Ciftci, E.; Erden, I.; Akyar, S.

    1998-01-01

    We report a rare case of neurobrucellosis in a 25-year-old woman with visual impairment, bilateral hearing loss, hyperprolactinaemia and meningitis. MRI revealed a sellar and suprasellar mass with enlargement of the optic chiasm. (orig.)

  9. Surface micro topography replication in injection moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf

    Thermoplastic injection moulding is a widely used industrial process that involves surface generation by replication. The surface topography of injection moulded plastic parts can be important for aesthetical or technical reasons. With the emergence of microengineering and nanotechnology additional...... importance of surface topography follows. In general the replication is not perfect and the topography of the plastic part differs from the inverse topography of the mould cavity. It is desirable to be able to control the degree of replication perfection or replication quality. This requires an understanding...... of the physical mechanisms of replication. Such understanding can lead to improved process design and facilitate in-line process quality control with respect to surface properties. The purpose of the project is to identify critical factors that affect topography replication quality and to obtain an understanding...

  10. MRI-guided periradicular nerve root infiltration therapy in low-field (0.23-T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Sequeiros, Roberto Blanco; Ojala, Risto O.; Klemola, Rauli; Jyrkinen, Lasse; Tervonen, Osmo A.; Vaara, Teuvo J.

    2002-01-01

    The purpose of this study was to evaluate the feasibility of the MRI-guided periradicular nerve root infiltration therapy. Sixty-seven nerve root infiltrations under MRI guidance were done for 61 patients suffering from lumbosacral radicular pain. Informed consent was acquired from all patients. A 0.23-T open-MRI scanner with interventional tools (Outlook Proview, Philips Medical Systems, MR Technologies, Finland) was used. A surface coil was used in all cases. Nerve root infiltration was performed with MRI-compatible 20-G needle (Chiba type MReye, Cook, Bloomington, Ind.; or Manan type, MD Tech, Florida). The evaluation of clinical outcome was achieved with 6 months of clinical follow-up and questionnaire. The effect of nerve root infiltration to the radicular pain was graded: 1=good to excellent, i.e., no pain or not disturbing pain allowing normal physical activity at 3 months from the procedure; 2=temporary, i.e., temporary relief of pain; 3=no relief of pain; and 4=worsening of pain. As an adjunct to MRI-guided positioning of the needle the correct needle localization by the nerve root was confirmed with saline injection to nerve root channel and single-shot fast spin echo (SSFSE) imaging. The MRI guidance allowed adequate needle positioning in all but 1 case (98.5%). This failure was caused by degeneration-induced changes in anatomy. Of patients, 51.5% had good to excellent effect with regard to radicular pain from the procedure, 22.7% had temporary relief, 21.2% had no effect, and in 4.5% the pain worsened. Our results show that MRI guidance is accurate and safe in performing nerve root infiltration at lumbosacral area. The results of radicular pain relief from nerve root infiltration are comparable to CT or fluoroscopy studies on the subject. (orig.)

  11. Asymmetric three-dimensional topography over mantle plumes.

    Science.gov (United States)

    Burov, Evgueni; Gerya, Taras

    2014-09-04

    The role of mantle-lithosphere interactions in shaping surface topography has long been debated. In general, it is supposed that mantle plumes and vertical mantle flows result in axisymmetric, long-wavelength topography, which strongly differs from the generally asymmetric short-wavelength topography created by intraplate tectonic forces. However, identification of mantle-induced topography is difficult, especially in the continents. It can be argued therefore that complex brittle-ductile rheology and stratification of the continental lithosphere result in short-wavelength modulation and localization of deformation induced by mantle flow. This deformation should also be affected by far-field stresses and, hence, interplay with the 'tectonic' topography (for example, in the 'active/passive' rifting scenario). Testing these ideas requires fully coupled three-dimensional numerical modelling of mantle-lithosphere interactions, which so far has not been possible owing to the conceptual and technical limitations of earlier approaches. Here we present new, ultra-high-resolution, three-dimensional numerical experiments on topography over mantle plumes, incorporating a weakly pre-stressed (ultra-slow spreading), rheologically realistic lithosphere. The results show complex surface evolution, which is very different from the smooth, radially symmetric patterns usually assumed as the canonical surface signature of mantle upwellings. In particular, the topography exhibits strongly asymmetric, small-scale, three-dimensional features, which include narrow and wide rifts, flexural flank uplifts and fault structures. This suggests a dominant role for continental rheological structure and intra-plate stresses in controlling dynamic topography, mantle-lithosphere interactions, and continental break-up processes above mantle plumes.

  12. The influence of surface topography of UV coated and printed cardboard on the print gloss

    Directory of Open Access Journals (Sweden)

    Igor Karlović

    2010-09-01

    Full Text Available The incident light on the printed surface undergoes through several processes of scattering, absorbtion and reflectiondepending on the surface topography and structure of the material. The specular part of the surface reflection is commonlyattributed as the geometric component of the reflection, and when measured is associated with specular gloss.The diffuse part of the surface reflection contains the chromatic part of the reflection and is commonly calculatedthrough colorimetric values. Using UV coatings as surface enhacement materials which affect the optical propertiesof coated surfaces and final appearance of the printed product forms new surface topography over the existingone. We have investigated the influence of three different amounts of UV glossy and matte oveprint coating on themeasured specular gloss of printed cardboard samples. The different amount of coatings on the printed samples wereachived using three different screen stencils of 180 threads/cm, 150 threads/cm and 120 threads/cm thread count.The cardboard samples were analysed with AFM and SEM microscopes to obtain surface topography and roughnessvalues which were evaluated with the measured geometric values speficied as instrumental gloss. The surfaceswith a specific amount of UV coatings showed a new formed topography which influences the reflection of light.The changes in topography were evaluated through surface roughness parameters which showed a decline of surfaceroughness with tht additional ammount of glossy and matte coatings. The obtained and calculated correlations showthere is a high correlation between coating ammount and surface roughness change and gloss for the glossy UVcoating. The results for the matte UV coatings showed lower correlation for the gloss and surface roughness.

  13. High-speed X-ray topography

    International Nuclear Information System (INIS)

    Eckers, W.; Oppolzer, H.

    1977-01-01

    The investigation of lattice defects in semiconductor crystals by conventional X-ray diffraction topography is very time-consuming. Exposure times can be reduced by using high-intensity X-rays and X-ray image intensifiers. The described system comprises a high-power rotating-anode X-ray tube, a remote-controlled X-ray topography camera, and a television system operating with an X-ray sensing VIDICON. System performance is demonstrated with reference to exploratory examples. The exposure time for photographic plates is reduced to 1/20 and for the X-ray TV system (resolution of the order of 30 μm) to 1/100 relative to that required when using a conventional topography system. (orig.) [de

  14. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  15. Brucellosis of the pituitary region: MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ciftci, E.; Erden, I.; Akyar, S. [Department of Radiology, University of Ankara (Turkey)

    1998-06-01

    We report a rare case of neurobrucellosis in a 25-year-old woman with visual impairment, bilateral hearing loss, hyperprolactinaemia and meningitis. MRI revealed a sellar and suprasellar mass with enlargement of the optic chiasm. (orig.) With 1 fig., 6 refs.

  16. Corneal topography measurements for biometric applications

    Science.gov (United States)

    Lewis, Nathan D.

    The term biometrics is used to describe the process of analyzing biological and behavioral traits that are unique to an individual in order to confirm or determine his or her identity. Many biometric modalities are currently being researched and implemented including, fingerprints, hand and facial geometry, iris recognition, vein structure recognition, gait, voice recognition, etc... This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have his or her corneal topography measured. Human subject topography data were collected with this device and compared to measurements made with the commercially available Keratron Piccolo topographer (Optikon, Rome, Italy). A third topographer that departs from the standard Placido disk technology allows for arbitrary pattern illumination through the use of LCD monitors. This topographer was built and tested to be used in future research studies. Topography data was collected from 59 subjects and modeled using Zernike polynomials, which provide for a simple method of compressing topography data and comparing one topographical measurement with a database for biometric identification. The data were analyzed to determine the biometric error rates associated with corneal topography measurements. Reasonably accurate results, between three to eight percent simultaneous false match and false non-match rates, were achieved.

  17. Fabricating binary optics: An overview of binary optics process technology

    Science.gov (United States)

    Stern, Margaret B.

    1993-01-01

    A review of binary optics processing technology is presented. Pattern replication techniques have been optimized to generate high-quality efficient microoptics in visible and infrared materials. High resolution optical photolithography and precision alignment is used to fabricate maximally efficient fused silica diffractive microlenses at lambda = 633 nm. The degradation in optical efficiency of four-phase-level fused silica microlenses resulting from an intentional 0.35 micron translational error has been systematically measured as a function of lens speed (F/2 - F/60). Novel processes necessary for high sag refractive IR microoptics arrays, including deep anisotropic Si-etching, planarization of deep topography and multilayer resist techniques, are described. Initial results are presented for monolithic integration of photonic and microoptic systems.

  18. Historical development of synchrotron x-ray diffraction topography

    International Nuclear Information System (INIS)

    Kawado, Seiji

    2011-01-01

    After a short history of X-ray diffraction topography, from the early stage of laboratory X-ray topography to recent synchrotron-radiation applications, is described, the development of science and technology for the synchrotron X-ray topography and its industrial applications are reviewed in more detail. In addition, the recent trend to synchrotron topography research is clarified on the basis of several data obtained from 256 papers which have been published since 2000. (author)

  19. Topography and diffractometry station in synchrotron radiation beam of the VEPP-4 storage ring. Topography of garnets

    International Nuclear Information System (INIS)

    Kub, I.; Poltsarova, M.; Panchenko, V.E.

    1987-01-01

    Advantages of synchrotron radiation (SR) spectrum of the VEhPP-4 storage ring for X-ray topography and diffractometry are shown. The description of ''Topography and diffractometry'' station in SR dump station of the VEhPP storage ring is presented, peculiarities of X-ray topography method used are discussed. X-ray topographic images of gadolinium-gallium and manganese-germanium garnets taken on the VEhPP SR are given in comparison with conventional images taken using X-ray tubes and SR of the VEhPP-3 storage ring

  20. X-ray topographic studies of organic and non-linear optical materials

    International Nuclear Information System (INIS)

    Halfpenny, P. J.; Sherwood, J. N.; Simpson, G. S.

    1997-01-01

    The flexible and non-destructive nature of X-ray topography is ideally suited to the study of large single crystals for both fundamental research and technological applications as well as the optimisation of crystal growth processes. Three examples are discussed, illustrating the application of X-ray topographic methods to non-linear optical (NLO) crystals. Synchrotron radiation section topography has been applied to the examination of large organic crystals. X-ray topography has been used to examine growth defects and the quality of crystals of m-nitroaniline (mNA) grown by the Bridgeman method. These studies allow evaluation of growth parameters together with their influence on defect density and show that in the case of mNA, remarkably low defect densities can be achieved under optimum growth conditions. Double-crystal reflection topography, with synchrotron radiation has been used to image defects intersecting the (011) faces of the inorganic NLO material potassium titanyl phosphate (KTP). X-ray images have been combined with optical microscopy and interferometry to provide valuable information on the crystal growth process

  1. Multiscale Study of Currents Affected by Topography

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Multiscale Study of Currents Affected by Topography ...the effects of topography on the ocean general and regional circulation with a focus on the wide range of scales of interactions. The small-scale...details of the topography and the waves, eddies, drag, and turbulence it generates (at spatial scales ranging from meters to mesoscale) interact in the

  2. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  3. Functional analysis screening for multiple topographies of problem behavior.

    Science.gov (United States)

    Bell, Marlesha C; Fahmie, Tara A

    2018-04-23

    The current study evaluated a screening procedure for multiple topographies of problem behavior in the context of an ongoing functional analysis. Experimenters analyzed the function of a topography of primary concern while collecting data on topographies of secondary concern. We used visual analysis to predict the function of secondary topographies and a subsequent functional analysis to test those predictions. Results showed that a general function was accurately predicted for five of six (83%) secondary topographies. A specific function was predicted and supported for a subset of these topographies. The experimenters discuss the implication of these results for clinicians who have limited time for functional assessment. © 2018 Society for the Experimental Analysis of Behavior.

  4. Design considerations in projection phase-shift moiré topography based on theoretical analysis of fringe formation.

    Science.gov (United States)

    Buytaert, Jan A N; Dirckx, Joris J J

    2007-07-01

    Moiré topography is a well-established optical technique to measure the shape of three-dimensional surfaces, based on the geometric interference between an optical grid and its image deformed by an object surface. The technique produces fringes that represent contours of equal height, and from the recordings of several phase-shifted topograms surface height coordinates can be calculated. To perform these calculations, it is assumed that object height variation is small in comparison with the measurement setup dimensions, and this approximation leads to systematic errors in measurement accuracy. We present the mathematical description of the fringe formation process in projection moiré topography, and on the basis of these equations we establish the relation between setup geometry and upper limits of the systematic measurement errors. We derive the equations that determine design specifications needed to reduce the effects of approximations to be below the measurement resolution of the setup. It is shown that setup geometry should be adapted to the gray-scale measurement resolution of the imaging system. We show that, using an iterative correction from one fringe order to the next, measurement accuracy can be maintained over the entire object depth.

  5. Importance of dynamic topography in Himalaya-Tibetan plateau region

    Science.gov (United States)

    Ghosh, A.; Singh, S.

    2017-12-01

    Himalaya-Tibetan plateau region has the highest topography in the world. Various studies have been done to understand the mechanisms responsible for sustaining this high topography. However, the existence of dynamic topography in this region is still uncertain, though there have been some studies exploring the role of channel flow in lower crust leading to some topography. We investigated the role of radial mantle flow in this region by studying the relationship between geoid and topography. High geoid-to-topography ratios (GTR) were observed along the Himalayas suggesting deeper compensation mechanisms. However, further north, the geoid and topography relationship became a lot more complex as high as well as low GTR values were observed. The high GTR regions also coincided with area of high filtered free air gravity anomalies, indicating dynamic support. We also looked at the spectral components of gravity, geoid and topography, and calculated response functions to distinguish between different compensation mechanisms. We estimated the average elastic thickness of the whole region to be around 40 km from coherence and admittance studies. The GTR and admittance-coherence studies suggest deeper mass anomalies playing a role in supporting the topography along Himalayas and the area between Altyn Tagh and Kunlun faults.

  6. On effects of topography in rotating flows

    Science.gov (United States)

    Burmann, Fabian; Noir, Jerome; Jackson, Andrew

    2017-11-01

    Both, seismological studies and geodynamic arguments suggest that there is significant topography at the core mantle boundary (CMB). This leads to the question whether the topography of the CMB could influence the flow in the Earth's outer core. As a preliminary experiment, we investigate the effects of bottom topography in the so-called Spin-Up, where motion of a contained fluid is created by a sudden increase of rotation rate. Experiments are performed in a cylindrical container mounted on a rotating table and quantitative results are obtained with particle image velocimetry. Several horizontal length scales of topography (λ) are investigated, ranging from cases where λ is much smaller then the lateral extend of the experiment (R) to cases where λ is a fraction of R. We find that there is an optimal λ that creates maximum dissipation of kinetic energy. Depending on the length scale of the topography, kinetic energy is either dissipated in the boundary layer or in the bulk of the fluid. Two different phases of fluid motion are present: a starting flow in the from of solid rotation (phase I), which is later replaced by meso scale vortices on the length scale of bottom topography (phase II).

  7. Impact of lithospheric rheology on surface topography

    Science.gov (United States)

    Liao, K.; Becker, T. W.

    2017-12-01

    The expression of mantle flow such as due to a buoyant plume as surface topography is a classical problem, yet the role of rheological complexities could benefit from further exploration. Here, we investigate the topographic expressions of mantle flow by means of numerical and analytical approaches. In numerical modeling, both conventional, free-slip and more realistic, stress-free boundary conditions are applied. For purely viscous rheology, a high viscosity lithosphere will lead to slight overestimates of topography for certain settings, which can be understood by effectively modified boundary conditions. Under stress-free conditions, numerical and analytical results show that the magnitude of dynamic topography decreases with increasing lithosphere thickness (L) and viscosity (ηL), as L-1 and ηL-3. The wavelength of dynamic topography increases linearly with L and (ηL/ ηM) 1/3. We also explore the time-dependent interactions of a rising plume with the lithosphere. For a layered lithosphere with a decoupling weak lower crust embedded between stronger upper crust and lithospheric mantle, dynamic topography increases with a thinner and weaker lower crust. The dynamic topography saturates when the decoupling viscosity is 3-4 orders lower than the viscosity of upper crust and lithospheric mantle. We further explore the role of visco-elastic and visco-elasto-plastic rheologies.

  8. An Integrated Use of Topography with RSI in Gully Mapping, Shandong Peninsula, China

    OpenAIRE

    He, Fuhong; Wang, Tao; Gu, Lijuan; Li, Tao; Jiang, Weiguo; Shao, Hongbo

    2014-01-01

    Taking the Quickbird optical satellite imagery of the small watershed of Beiyanzigou valley of Qixia city, Shandong province, as the study data, we proposed a new method by using a fused image of topography with remote sensing imagery (RSI) to achieve a high precision interpretation of gully edge lines. The technique first transformed remote sensing imagery into HSV color space from RGB color space. Then the slope threshold values of gully edge line and gully thalweg were gained through field...

  9. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  10. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  11. Optical System Design and Integration of the Mercury Laser Altimeter

    Science.gov (United States)

    Ramos-Izquierdo, Luis; Scott, V. Stanley, III; Schmidt, Stephen; Britt, Jamie; Mamakos, William; Trunzo, Raymond; Cavanaugh, John; Miller, Roger

    2005-01-01

    The Mercury Laser Altimeter (MLA). developed for the 2004 MESSENGER mission to Mercury, is designed to measure the planet's topography via laser ranging. A description of the MLA optical system and its measured optical performance during instrument-level and spacecraft-level integration and testing are presented.

  12. Geology, Bedrock - BEDROCK_TOPOGRAPHY_MM36_IN: Bedrock Topography Contours, Indiana (Indiana Geological Survey, 1:500,000, Line Shapefile)

    Data.gov (United States)

    NSGIC State | GIS Inventory — Bedrock topography was converted from the original published map, Indiana Geological Survey Miscellaneous Map 36. The contours define the elevation/topography of the...

  13. Corneal topography with an aberrometry-topography system.

    Science.gov (United States)

    Mülhaupt, Michael; Dietzko, Sven; Wolffsohn, James; Bandlitz, Stefan

    2018-05-07

    To investigate the agreement between the central corneal radii and corneal eccentricity measurements generated by the new Wave Analyzer 700 Medica (WAV) compared to the Keratograph 4 (KER) and to test the repeatability of the instruments. 20 subjects (10 male, mean age 29.1 years, range 21-50 years) were recruited from the students and staff of the Cologne School of Optometry. Central corneal radii for the flat (r c/fl ) and steep (r c/st ) meridian as well as corneal eccentricity for the nasal (e nas ), temporal (e temp ), inferior (e inf ) and superior (e sup ) directions were measured using WAV and KER by one examiner in a randomized order. Central radii of the flat (r c/fl ) and steep (r c/st ) meridian measured with both instruments were statically significantly correlated (r = 0.945 and r = 0.951; p  0.05). Limits of agreement (LoA) indicate a better repeatability for the KER compared to WAV. Corneal topography measurements captured with the WAV were strongly correlated with the KER. However, due to the differences in measured corneal radii and eccentricities, the devices cannot be used interchangeably. For corneal topography the KER demonstrated better repeatability. Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Relationship of Aphasia and Topography of Cerebrovascular Territories

    Directory of Open Access Journals (Sweden)

    K. Ghandehari

    2004-10-01

    Full Text Available Aphasia is a common manifestation of stroke and evaluation of relationships of aphasia and brain topography could lead to better understanding of cognitive neurophysiology.Consecutive 100 stroke patients with aphasia admitted in Valie Asr hospital, Khorasan in 2003 enrulled in this prospective study. Diagnosis of stroke and aphasia was made by a neurolosist and topography of involved cerebrovascular territories confirmed by topographic maps of brain in CT scan. Global, Broca and Wernicke subtypes of aphasia constituted 52%, 40% and 6% of the cases respectively. Based on the usual nourishment of Broca and Wernicke areas by anterior and posterior cortical branches of the middle cerebral artery, 79% of Global, 47% of Broca and 50% of Wernicke aphasias had a compatible infarct topography. Other cases had no congruent infarct topography with involved linguistic area of their brain. Specific cerebrovascular topography for subtypes of aphasia in stroke patients was not found. The effects of cerebrovascular lesions on linguistic functions are not predictable by their topography in CT scan.

  15. Novel Electro-Optical Coupling Technique for Magnetic Resonance-Compatible Positron Emission Tomography Detectors

    Directory of Open Access Journals (Sweden)

    Peter D. Olcott

    2009-03-01

    Full Text Available A new magnetic resonance imaging (MRI-compatible positron emission tomography (PET detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  16. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    Science.gov (United States)

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  17. Detection of optic nerve lesions in optic neuritis using frequency-selective fat-saturation sequences

    International Nuclear Information System (INIS)

    Miller, D.H.; MacManus, D.G.; Bartlett, P.A.; Kapoor, R.; Morrissey, S.P.; Moseley, I.F.

    1993-01-01

    MRI was performed on seven patients with acute optic neuritis, using two sequences which suppress the signal from orbital fat: frequency-selective fat-saturation and inversion recovery with a short inversion time. Lesions were seen on both sequences in all the symptomatic optic nerves studied. (orig.)

  18. Non-invasive assessment of hemispheric language dominance by optical topography during a brief passive listening test: a pilot study.

    Science.gov (United States)

    Bembich, Stefano; Demarini, Sergio; Clarici, Andrea; Massaccesi, Stefano; Grasso, Domenico Loenardo

    2011-12-01

    The Wada test is usually used for pre-surgical assessment of language lateralization. Considering its invasiveness and risk of complications, alternative methods have been proposed but they are not always applicable to non-cooperative patients. In this study we explored the possibility of using optical topography (OT)--a multichannel near-infrared system--for non-invasive assessment of hemispheric language dominance during passive listening. Cortical activity was monitored in a sample of healthy, adult Italian native speakers, all right-handed. We assessed changes in oxy-haemoglobin concentration in temporal, parietal and posterior frontal lobes during a passive listening of bi-syllabic words and vowel-consonant-vowel syllables lasting less then 3 minutes. Activated channels were identified by t tests. Left hemisphere showed significant activity only during the passive listening of bi-syllabic words. Specifically, the superior temporal gyrus, the supramarginal gyrus and the posterior inferior parietal lobe were activated. During passive listening of bi-syllabic words, right handed healthy adults showed a significant activation in areas already known to be involved in speech comprehension. Although more research is needed, OT proved to be a promising alternative to the Wada test for non-invasive assessment of hemispheric language lateralization, even if using a particularly brief trial, which has been designed for future applications with non-cooperative subjects.

  19. Origin of bending in uncoated microcantilever - Surface topography?

    International Nuclear Information System (INIS)

    Lakshmoji, K.; Prabakar, K.; Tripura Sundari, S.; Jayapandian, J.; Tyagi, A. K.; Sundar, C. S.

    2014-01-01

    We provide direct experimental evidence to show that difference in surface topography on opposite sides of an uncoated microcantilever induces bending, upon exposure to water molecules. Examination on opposite sides of the microcantilever by atomic force microscopy reveals the presence of localized surface features on one side, which renders the induced stress non-uniform. Further, the root mean square inclination angle characterizing the surface topography shows a difference of 73° between the opposite sides. The absence of deflection in another uncoated microcantilever having similar surface topography confirms that in former microcantilever bending is indeed induced by differences in surface topography

  20. Applications of synchrotron x-ray diffraction topography to fractography

    International Nuclear Information System (INIS)

    Bilello, J.C.

    1983-01-01

    Fractographs have been taken using a variety of probes each of which produces different types of information. Methods which have been used to examine fracture surfaces include: (a) optical microscopy, particularly interference contrast methods, (b) scanning electron microscopy (SEM), (c) SEM with electron channelling, (d) SEM with selected-area electron channelling, (e) Berg-Barrett (B-B) topography, and now (f) synchrotron x-radiation fractography (SXRF). This review concentrated on the role that x-ray methods can play in such studies. In particular, the ability to nondestructively assess the subsurface microstructure associated with the fracture to depths of the order of 5 to 10 μm becomes an important attribute for observations of a large class of semi-brittle metals, semiconductors and ceramics

  1. Electronic Cigarette Topography in the Natural Environment.

    Science.gov (United States)

    Robinson, R J; Hensel, E C; Morabito, P N; Roundtree, K A

    2015-01-01

    This paper presents the results of a clinical, observational, descriptive study to quantify the use patterns of electronic cigarette users in their natural environment. Previously published work regarding puff topography has been widely indirect in nature, and qualitative rather than quantitative, with the exception of three studies conducted in a laboratory environment for limited amounts of time. The current study quantifies the variation in puffing behaviors among users as well as the variation for a given user throughout the course of a day. Puff topography characteristics computed for each puffing session by each subject include the number of subject puffs per puffing session, the mean puff duration per session, the mean puff flow rate per session, the mean puff volume per session, and the cumulative puff volume per session. The same puff topography characteristics are computed across all puffing sessions by each single subject and across all subjects in the study cohort. Results indicate significant inter-subject variability with regard to puffing topography, suggesting that a range of representative puffing topography patterns should be used to drive machine-puffed electronic cigarette aerosol evaluation systems.

  2. MRI texture heterogeneity in the optic nerve predicts visual recovery after acute optic neuritis

    Directory of Open Access Journals (Sweden)

    Yunyan Zhang

    2014-01-01

    Conclusions: Tissue heterogeneity may be a potential measure of functional outcome in ON patients and advanced analysis of the texture in standard MRI could provide insights into mechanisms of injury and recovery in patients with similar disorders.

  3. Can we improve accuracy and reliability of MRI interpretation in children with optic pathway glioma? Proposal for a reproducible imaging classification

    Energy Technology Data Exchange (ETDEWEB)

    Lambron, Julien; Frampas, Eric; Toulgoat, Frederique [University Hospital, Department of Radiology, Nantes (France); Rakotonjanahary, Josue [University Hospital, Department of Pediatric Oncology, Angers (France); University Paris Diderot, INSERM CIE5 Robert Debre Hospital, Assistance Publique-Hopitaux de Paris (AP-HP), Paris (France); Loisel, Didier [University Hospital, Department of Radiology, Angers (France); Carli, Emilie de; Rialland, Xavier [University Hospital, Department of Pediatric Oncology, Angers (France); Delion, Matthieu [University Hospital, Department of Neurosurgery, Angers (France)

    2016-02-15

    Magnetic resonance (MR) images from children with optic pathway glioma (OPG) are complex. We initiated this study to evaluate the accuracy of MR imaging (MRI) interpretation and to propose a simple and reproducible imaging classification for MRI. We randomly selected 140 MRIs from among 510 MRIs performed on 104 children diagnosed with OPG in France from 1990 to 2004. These images were reviewed independently by three radiologists (F.T., 15 years of experience in neuroradiology; D.L., 25 years of experience in pediatric radiology; and J.L., 3 years of experience in radiology) using a classification derived from the Dodge and modified Dodge classifications. Intra- and interobserver reliabilities were assessed using the Bland-Altman method and the kappa coefficient. These reviews allowed the definition of reliable criteria for MRI interpretation. The reviews showed intraobserver variability and large discrepancies among the three radiologists (kappa coefficient varying from 0.11 to 1). These variabilities were too large for the interpretation to be considered reproducible over time or among observers. A consensual analysis, taking into account all observed variabilities, allowed the development of a definitive interpretation protocol. Using this revised protocol, we observed consistent intra- and interobserver results (kappa coefficient varying from 0.56 to 1). The mean interobserver difference for the solid portion of the tumor with contrast enhancement was 0.8 cm{sup 3} (limits of agreement = -16 to 17). We propose simple and precise rules for improving the accuracy and reliability of MRI interpretation for children with OPG. Further studies will be necessary to investigate the possible prognostic value of this approach. (orig.)

  4. Ganglioglioma of the trigeminal nerve: MRI

    Energy Technology Data Exchange (ETDEWEB)

    Athale, S.; Jinkins, J.R. [Neuroradiology Section, The University of Texas Health Science Center at San Antonio, 7703 F. Curl Drive, San Antonio, TX 78284-7800 (United States); Hallet, K.K. [Neuropathology Department, The University of Texas Health Science Center at San Antonio, Texas (United States)

    1999-08-01

    Ganglioglioma of the cranial nerves is extremely rare; only a few cases involving the optic nerves have been reported. We present a case of ganglioglioma of the trigeminal nerve, which was isointense with the brain stem on all MRI sequences and showed no contrast enhancement. (orig.) With 2 figs., 6 refs.

  5. Characterizing smoking topography of cannabis in heavy users

    Science.gov (United States)

    Stitzer, Maxine L.; Vandrey, Ryan

    2013-01-01

    Rationale Little is known about the smoking topography characteristics of heavy cannabis users. Such measures may be able to predict cannabis use-related outcomes and could be used to validate self-reported measures of cannabis use. Objectives The current study was conducted to measure cannabis smoking topography characteristics during periods of ad libitum use and to correlate topography assessments with measures of self-reported cannabis use, withdrawal and craving during abstinence, and cognitive task performance. Methods Participants (N=20) completed an inpatient study in which they alternated between periods of ad libitum cannabis use and abstinence. Measures of self-reported cannabis use, smoking topography, craving, withdrawal, and sleep measures were collected. Results Participants smoked with greater intensity (e.g., greater volume, longer duration) on initial cigarette puffs with a steady decline on subsequent puffs. Smoking characteristics were significantly correlated with severity of withdrawal, notably sleep quality and architecture, and craving during abstinence, suggesting dose-related effects of cannabis use on these outcomes. Smoking characteristics generally were not significantly associated with cognitive performance. Smoking topography measures were significantly correlated with self-reported measures of cannabis use, indicating validity of these assessments, but topography measures were more sensitive than self-report in predicting cannabis-related outcomes. Conclusions A dose–effect relationship between cannabis consumption and outcomes believed to be clinically important was observed. With additional research, smoking topography assessments may become a useful clinical tool. PMID:21922170

  6. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  7. Lithography-Free Fabrication of Reconfigurable Substrate Topography For Contact Guidance

    Science.gov (United States)

    Pholpabu, Pitirat; Kustra, Stephen; Wu, Haosheng; Balasubramanian, Aditya; Bettinger, Christopher J.

    2014-01-01

    Mammalian cells detect and respond to topographical cues presented in natural and synthetic biomaterials both in vivo and in vitro. Micro- and nano-structures influence the adhesion, morphology, proliferation, migration, and differentiation of many phenotypes. Although the mechanisms that underpin cell-topography interactions remain elusive, synthetic substrates with well-defined micro- and nano-structures are important tools to elucidate the origin of these responses. Substrates with reconfigurable topography are desirable because programmable cues can be harmonized with dynamic cellular responses. Here we present a lithography-free fabrication technique that can reversibly present topographical cues using an actuation mechanism that minimizes the confounding effects of applied stimuli. This method utilizes strain-induced buckling instabilities in bi-layer substrate materials with rigid uniform silicon oxide membranes that are thermally deposited on elastomeric substrates. The resulting surfaces are capable of reversible of substrates between three distinct states: flat substrates (A = 1.53 ± 0.55 nm, Rms = 0.317 ± 0.048 nm); parallel wavy grating arrays (A|| = 483.6 ± 7.8 nm and λ|| = 4.78 ± 0.16 μm); perpendicular wavy grating arrays (A⊥ = 429.3 ± 5.8 nm; λ⊥ = 4.95 ± 0.36 μm). The cytoskeleton dynamics of 3T3 fibroblasts in response to these surfaces was measured using optical microscopy. Fibroblasts cultured on dynamic substrates that are switched from flat to topographic features (FLAT-WAVY) exhibit a robust and rapid change in gross morphology as measured by a reduction in circularity from 0.30 ± 0.13 to 0.15 ± 0.08 after 5 min. Conversely, dynamic substrate sequences of FLAT-WAVY-FLAT do not significantly alter the gross steady-state morphology. Taken together, substrates that present topographic structures reversibly can elucidate dynamic aspects of cell-topography interactions. PMID:25468368

  8. Probing the brain with molecular fMRI.

    Science.gov (United States)

    Ghosh, Souparno; Harvey, Peter; Simon, Jacob C; Jasanoff, Alan

    2018-04-09

    One of the greatest challenges of modern neuroscience is to incorporate our growing knowledge of molecular and cellular-scale physiology into integrated, organismic-scale models of brain function in behavior and cognition. Molecular-level functional magnetic resonance imaging (molecular fMRI) is a new technology that can help bridge these scales by mapping defined microscopic phenomena over large, optically inaccessible regions of the living brain. In this review, we explain how MRI-detectable imaging probes can be used to sensitize noninvasive imaging to mechanistically significant components of neural processing. We discuss how a combination of innovative probe design, advanced imaging methods, and strategies for brain delivery can make molecular fMRI an increasingly successful approach for spatiotemporally resolved studies of diverse neural phenomena, perhaps eventually in people. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Stochastic analysis of 1D and 2D surface topography of x-ray mirrors

    Science.gov (United States)

    Tyurina, Anastasia Y.; Tyurin, Yury N.; Yashchuk, Valeriy V.

    2017-08-01

    The design and evaluation of the expected performance of new optical systems requires sophisticated and reliable information about the surface topography for planned optical elements before they are fabricated. The problem is especially complex in the case of x-ray optics, particularly for the X-ray Surveyor under development and other missions. Modern x-ray source facilities are reliant upon the availability of optics with unprecedented quality (surface slope accuracy quality optics. The uniqueness of the optics and limited number of proficient vendors makes the fabrication extremely time consuming and expensive, mostly due to the limitations in accuracy and measurement rate of metrology used in fabrication. We discuss improvements in metrology efficiency via comprehensive statistical analysis of a compact volume of metrology data. The data is considered stochastic and a new statistical model called Invertible Time Invariant Linear Filter (InTILF) is developed now for 2D surface profiles to provide compact description of the 2D data additionally to 1D data treated so far. The model captures faint patterns in the data and serves as a quality metric and feedback to polishing processes, avoiding high resolution metrology measurements over the entire optical surface. The modeling, implemented in our Beatmark software, allows simulating metrology data for optics made by the same vendor and technology. The forecast data is vital for reliable specification for optical fabrication, to be exactly adequate for the required system performance.

  10. Scanning tunneling microscope for magneto-optical imaging

    NARCIS (Netherlands)

    Prins, M.W.J.; Groeneveld, R.H.M.; Abraham, D.L.; Schad, R.; Kempen, van H.; Kesteren, van H.W.

    1996-01-01

    Images of magnetic bits written in a Pt/Co multilayer are presented. Using photosensitive semiconducting tips in a scanning tunneling microscope the surface topography as well as the polarization-dependent optical transmission are measured. Magnetic contrast is achieved by detection of the Faraday

  11. A comparison of the value of MRI and CT in patients with Nelson syndrome

    International Nuclear Information System (INIS)

    Kersjes, W.; Allmendinger, S.; Christ, F.; Stiebler, H.; Bockisch, A.; Klingmueller, D.

    1992-01-01

    The hypophyses of 13 patients with Nelson syndrome following bilateral adrenalectomy were examined by MRI and CT. Diffuse enlargement of the hypophysis was demonstrated in 8 patients by CT and in 9 by MRI. Compared with CT, MRI provides better demonstration of tumour development, such as abnormal convexity of the cranial margin of the hypophysis (MRI 4/13, CT 1/13), displacement of the infundibulum (MRI 4/13, CT 0/13) or optic chiasm (MRI 2/13, CT 0/13). MRI also provides diagnostically important differentiation between scar tissue and recurrence of tumour following hypophysectomy (MRI 1/3, CT 0/3) and more accurate demonstration of infiltration of the cavernous sinus (MRI 4/13, CT 2/13). CT is superior only in showing the floor of the sella. MRI is the method of choice for imaging in cases of Nelson syndrome. (orig.) [de

  12. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    International Nuclear Information System (INIS)

    Verhaart, René F.; Paulides, Margarethus M.; Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F.; Verduijn, Gerda M.; Lugt, Aad van der

    2014-01-01

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI db ). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T max ) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI db . Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient

  13. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Verhaart, René F., E-mail: r.f.verhaart@erasmusmc.nl; Paulides, Margarethus M. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Fortunati, Valerio; Walsum, Theo van; Veenland, Jifke F. [Biomedical Imaging Group of Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands); Verduijn, Gerda M. [Department of Radiation Oncology, Erasmus MC - Cancer Institute, Groene Hilledijk 301, Rotterdam 3008 AE (Netherlands); Lugt, Aad van der [Department of Radiology, Erasmus MC, Dr. Molewaterplein 50/60, Rotterdam 3015 GE (Netherlands)

    2014-12-15

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI{sub db}). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T{sub max}) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI{sub db}. Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm

  14. High-resolution MRI using orbit surface coils for the evaluation of metastatic risk factors in 143 children with retinoblastoma. Part 1: MRI vs. histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Sirin, Selma; Schlamann, Marc; Schweiger, Bernd; Goericke, Sophia L. [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Metz, Klaus A. [University Hospital Essen, Department of Pathology and Neuropathology, Essen (Germany); Bornfeld, Norbert; Holdt, Markus [University Hospital Essen, Department of Ophthalmology, Essen (Germany); Temming, Petra; Schuendeln, Michael M. [University Hospital Essen, Department of Pediatric Hematology and Oncology, Essen (Germany)

    2015-08-15

    A reliable detection of metastatic risk factors is important for children with retinoblastoma to choose the right therapeutic regimen. First studies using high-resolution magnetic resonance imaging (MRI) with orbit surface coils were promising. The aim of this study was therefore to evaluate the ability of high-resolution MRI to detect metastatic and especially advanced metastatic risk factors in a large group of children with retinoblastoma. One hundred forty-three consecutive children with retinoblastoma (148 enucleated eyes, 64 girls, 79 boys, mean age 19.7 ± 15.3) who received pretherapeutical high-resolution MRI with orbit surface coils on 1.5 T MR scanner systems between 2007 and 2012 and subsequent primary enucleation within 14 days were included in this retrospective study. Image analysis was performed by two neuroradiologists experienced in ocular imaging in consensus. Histopathology served as gold standard. Sensitivity/specificity for the detection of metastatic risk factors using high-resolution MRI with orbit surface coils were 60 %/88.7 % for postlaminar optic nerve infiltration, 65.5 %/95.6 % for choroidal invasion, 100 %/99.3 % for scleral invasion, and 100 %/100 % for peribulbar fat invasion, respectively. The results increased for the detection of advanced metastatic risk factors, 81.8 %/89.1 % for deep postlaminar optic nerve infiltration, 70.6 %/97.6 % for massive choroidal invasion. High-resolution MRI is clinically valuable for the detection of metastatic, especially of advanced metastatic risk factors in children with retinoblastoma. (orig.)

  15. Comparative study on findings of the brain computed tomography (X-ray-CT) and dynamic topography of VEP (VDT)

    International Nuclear Information System (INIS)

    Matsuura, Masashi

    1985-01-01

    Comparative study between morphological Xray-CT and functional VDT was conducted on 20 cases of cerebral diseases with visual dysfunction. Subjects were patients with cerebral infarction, intracranial hemorrhage, hemispherectomy, traumatic brain atrophy, brain tumor, Creutzfeldt-Jakob disease, anoxic encephalopathy, porencephaly, microcephaly and optic tract lesion. VEP topography was performed by flash stimulation and brain electrical activity mappings were displayed by EEG topography computer. In 9 cases out of 20, abolished function in VDT was correlated to the defective findings of Xray-CT. Cases with homonymous hemianopsia showed 2 types of BEAM. In cases with a lesion in the inner surface of the occipital lobe, asymmetric electric activity was distributed along the sagittal axis of the scalp. While, in cases with outer surface lesion of the occipital lobe, asymmetric electric activity appeared along the coronary axis. In cases with multi focal brain lesions in Xray-CT, there was no regular tendency in abnormality of VDT. Various aberration of VEP and VDT, such as component defect, stagnation, reduction, condensation and abnormal flow were demonstrated. In a case of optic tract lesion, Xray-CT showed no pathological findings but VDT showed a remarkable asymmetry of brain activity. (author)

  16. Clinical evolution of uncomplicated optic neuritis

    International Nuclear Information System (INIS)

    Milanese, C.; Visciani, A.; Campi, A.; Eoli, M.; La Mantia, L.; Salmaggi, A.; Nespolo, A.; Corridori, F.

    1988-01-01

    Magnetic Resonance Imaging (MRI) has been proved to be a very sensitive method for detecting demyelinating lesions in multiple sclerosis. Therefore, MRI was used to study patients with optical neuritis, to evaluate the possible presence of demyelinating lesions in the brain. The prognostic value of cerebrospinal fluid findings was also evaluated. 15 refs.; 4 tabs

  17. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2013-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scan...

  18. Simultaneous MRI and PET imaging of a rat brain

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Lemieux, Susan K [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Velan, S Sendhil [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Weisenberger, Andrew G [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Zorn, Carl [Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, VA (United States); Marano, Gary D [Center for Advanced Imaging, Department of Radiology, Box 9236, West Virginia University, Morgantown, WV (United States)

    2006-12-21

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging.

  19. Simultaneous MRI and PET imaging of a rat brain

    International Nuclear Information System (INIS)

    Raylman, Raymond R; Majewski, Stan; Lemieux, Susan K; Velan, S Sendhil; Kross, Brian; Popov, Vladimir; Smith, Mark F; Weisenberger, Andrew G; Zorn, Carl; Marano, Gary D

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI will allow the correlation of form with function. Our group is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode. Each MRI-PET detector module consists of an array of LSO detector elements coupled through a long fibre optic light guide to a single Hamamatsu flat panel position-sensitive photomultiplier tube (PSPMT). The use of light guides allows the PSPMTs to be positioned outside the bore of a 3T MRI scanner where the magnetic field is relatively small. To test the device, simultaneous MRI and PET images of the brain of a male Sprague Dawley rat injected with FDG were successfully obtained. The images revealed no noticeable artefacts in either image set. Future work includes the construction of a full ring PET scanner, improved light guides and construction of a specialized MRI coil to permit higher quality MRI imaging

  20. AFM Imaging of Natural Optical Structures

    Directory of Open Access Journals (Sweden)

    Dinara Sultanovna Dallaeva

    2014-01-01

    Full Text Available The research in this field is focused to the investigation of biological structures with superior optical features. The study presents atomic force microscopy of biological optical structures on butterfly wings. The bright blue and dark black color scales exhibit the different topography. These scales were compared to the visually the same color scales of other two species of butterflies. The histograms of heights distribution are presented and show similar results for the scales of one color for different species.

  1. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Brossmann, J. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Melchert, U.H. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Schroeder, C. [Radiologische Abt., Universitaets-Kinderklinik, Christian-Albrechts-Universitaet, Kiel (Germany); Boer, R. de [Philips Medical Systems, Best (Netherlands); Spielmann, R.P. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany); Heller, M. [Klinik fuer Radiologische Diagnostik, Univ. Kiel (Germany)

    1995-12-31

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  2. Functional MRI of the patellofemoral joint: comparison of ultrafast MRI, motion-triggered cine MRI and static MRI

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Melchert, U.H.; Schroeder, C.; Boer, R. de; Spielmann, R.P.; Heller, M.

    1995-01-01

    To evaluate the feasibility and usefulness of ultrafast MRI (u), patellar tracking from 30 of flexion to knee extension (0 ) was analysed and compared with motion-triggered cine MRI (m) and a static MRI technique (s). The different imaging methods were compared in respect of the patellofemoral relationship, the examination time and image quality. Eight healthy subjects and four patients (in total 18 joints) with patellar subluxation or luxation were examined. Significant differences between the static MRI series without quadriceps contraction and the functional MRI studies (motion-triggered cine MRI and ultrafast MRI) were found for the patellar tilt angle. In the dynamic joint studies there was no statistical difference of the regression coefficients between the motion-triggered cine MRI studies and the ultrafast MRI studies. The findings of the functional MRI studies compared with the static MRI images were significantly different for the lateralisation of the patella, expressed by the lateral patellar displacement and bisect offset. No significant differences in patellar lateralisation were found between motion-triggered cine MRI and ultrafast MRI. Ultrafast MRI was superior to motion-triggered cine MRI in terms of the reduction in imaging time and improvement of the image quality. (orig.)

  3. Evanescent field characterisation for a d-shaped optical fibre using scanning near-field optical microscopy

    International Nuclear Information System (INIS)

    Huntington, S.T.; Nugent, K.A.; Roberts, A.; Mulvaney, P.; Lo, K.M.

    1997-01-01

    Scanning near field optical microscopy is used to measure the evanescent filed and mode profile of a Ge-doped D-shaped optical fibre. The structure of the fibre is determined by differential etching followed by an investigation of the resultant topography with an atomic force microscope. This information is then used to theoretically model the expected behaviour of the fibre and it is shown that the theoretically model the expected behaviour of the fibre and it is shown that the theoretical results are in excellent agreement with the experimentally observed fields

  4. Improved automatic optic nerve radius estimation from high resolution MRI

    Science.gov (United States)

    Harrigan, Robert L.; Smith, Alex K.; Mawn, Louise A.; Smith, Seth A.; Landman, Bennett A.

    2017-02-01

    The optic nerve (ON) is a vital structure in the human visual system and transports all visual information from the retina to the cortex for higher order processing. Due to the lack of redundancy in the visual pathway, measures of ON damage have been shown to correlate well with visual deficits. These measures are typically taken at an arbitrary anatomically defined point along the nerve and do not characterize changes along the length of the ON. We propose a fully automated, three-dimensionally consistent technique building upon a previous independent slice-wise technique to estimate the radius of the ON and surrounding cerebrospinal fluid (CSF) on high-resolution heavily T2-weighted isotropic MRI. We show that by constraining results to be three-dimensionally consistent this technique produces more anatomically viable results. We compare this technique with the previously published slice-wise technique using a short-term reproducibility data set, 10 subjects, follow-up <1 month, and show that the new method is more reproducible in the center of the ON. The center of the ON contains the most accurate imaging because it lacks confounders such as motion and frontal lobe interference. Long-term reproducibility, 5 subjects, follow-up of approximately 11 months, is also investigated with this new technique and shown to be similar to short-term reproducibility, indicating that the ON does not change substantially within 11 months. The increased accuracy of this new technique provides increased power when searching for anatomical changes in ON size amongst patient populations.

  5. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: a comparison of CT and CT-MRI based tissue segmentation on simulated temperature.

    Science.gov (United States)

    Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van der Lugt, Aad; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M

    2014-12-01

    In current clinical practice, head and neck (H&N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors' study is to investigate the relevance of using MRI in addition to CT for patient modeling in H&N HTP. CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H&N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRIdb). To quantify the relevance of MRI based segmentation for H&N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (Tmax) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRIdb. In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient models based on CT (Tmax: 38.0 °C) and CT and MRI

  6. Experiments on topographies lacking tidal conversion

    Science.gov (United States)

    Maas, Leo; Paci, Alexandre; Yuan, Bing

    2015-11-01

    In a stratified sea, internal tides are supposedly generated when the tide passes over irregular topography. It has been shown that for any given frequency in the internal wave band there are an infinite number of exceptions to this rule of thumb. This ``stealth-like'' property of the topography is due to a subtle annihilation of the internal waves generated during the surface tide's passage over the irregular bottom. We here demonstrate this in a lab-experiment. However, for any such topography, subsequently changing the surface tide's frequency does lead to tidal conversion. The upshot of this is that a tidal wave passing over an irregular bottom is for a substantial part trapped to this irregularity, and only partly converted into freely propagating internal tides. Financially supported by the European Community's 7th Framework Programme HYDRALAB IV.

  7. Cognitive “Boy stories”: urban folklore and urban topographies

    Directory of Open Access Journals (Sweden)

    Bojan Žikić

    2016-02-01

    Full Text Available The culturally cognitive perception of Belgrade’s topographies is considered through its deployment, symbolic use and narrative foundation. As the explanatory material-one football-media incident, the use of certain areas of the city in a spectacleceremonial manner, knowledge and lore of certain elements of the Belgrade topographies and the organization of «the football Belgrade»-were considered. The attitude is taken that the topography of a city is a multifaceted cultural constituent, whose structure of particular meaning, as a part of cultural communication, is determined by the very fact it is an urban space. Physical aspects of spatial-ness are reduced to relationism, i.e. it has a meaning for the cultural communication only when the elements of urban topographies are brought into correlation. Other characteristics of physical spatial-ness are irrelevant for such communication. Meaning relations in which elements of urban topographies exist are formed on the very fact of them being urban, that is, the afore mentioned denotation that is ascribed to space, stems from those cultural features and artifacts that are associated in a given milieu with certain concrete elements of urban topographies.

  8. Diffusion processes in bombardment-induced surface topography

    International Nuclear Information System (INIS)

    Robinson, R.S.

    1984-01-01

    A treatment is given of the problem of surface diffusion processes occurring during surface topography development, whenever a surface is simultaneously seeded with impurities and ion bombarded. The development of controllable topography and the importance of surface diffusion parameters, which can be obtained during these studies, are also analyzed. 101 refs.; 7 figs.; 2 tabs

  9. The Dawn Topography Investigation

    Science.gov (United States)

    Raymond, C. A.; Jaumann, R.; Nathues, A.; Sierks, H.; Roatsch, T.; Preusker, E; Scholten, F.; Gaskell, R. W.; Jorda, L.; Keller, H.-U.; hide

    2011-01-01

    The objective of the Dawn topography investigation is to derive the detailed shapes of 4 Vesta and 1 Ceres in order to create orthorectified image mosaics for geologic interpretation, as well as to study the asteroids' landforms, interior structure, and the processes that have modified their surfaces over geologic time. In this paper we describe our approaches for producing shape models, plans for acquiring the needed image data for Vesta, and the results of a numerical simulation of the Vesta mapping campaign that quantify the expected accuracy of our results. Multi-angle images obtained by Dawn's framing camera will be used to create topographic models with 100 m/pixel horizontal resolution and 10 m height accuracy at Vesta, and 200 m/pixel horizontal resolution and 20 m height accuracy at Ceres. Two different techniques, stereophotogrammetry and stereophotoclinometry, are employed to model the shape; these models will be merged with the asteroidal gravity fields obtained by Dawn to produce geodetically controlled topographic models for each body. The resulting digital topography models, together with the gravity data, will reveal the tectonic, volcanic and impact history of Vesta, and enable co-registration of data sets to determine Vesta's geologic history. At Ceres, the topography will likely reveal much about processes of surface modification as well as the internal structure and evolution of this dwarf planet.

  10. Characterization of near-field optical probes

    DEFF Research Database (Denmark)

    Vohnsen, Brian; Bozhevolnyi, Sergey I.

    1999-01-01

    Radiation and collection characteristics of four different near-field optical-fiber probes, namely, three uncoated probes and an aluminium-coated small-aperture probe, are investigated and compared. Their radiation properties are characterized by observation of light-induced topography changes...... in a photo-sensitive film illuminated with the probes, and it is confirmed that the radiated optical field is unambigiously confined only for the coated probe. Near-field optical imaging of a standing evanescent-wave pattern is used to compare the detection characteristics of the probes, and it is concluded...... that, for the imaging of optical-field intensity distributions containing predominantly evanescent-wave components, a sharp uncoated tip is the probe of choice. Complementary results obtained with optical phase-conjugation experiments with he uncoated probes are discussed in relation to the probe...

  11. Fine-scale topography in sensory systems: insights from Drosophila and vertebrates.

    Science.gov (United States)

    Kaneko, Takuya; Ye, Bing

    2015-09-01

    To encode the positions of sensory stimuli, sensory circuits form topographic maps in the central nervous system through specific point-to-point connections between pre- and postsynaptic neurons. In vertebrate visual systems, the establishment of topographic maps involves the formation of a coarse topography followed by that of fine-scale topography that distinguishes the axon terminals of neighboring neurons. It is known that intrinsic differences in the form of broad gradients of guidance molecules instruct coarse topography while neuronal activity is required for fine-scale topography. On the other hand, studies in the Drosophila visual system have shown that intrinsic differences in cell adhesion among the axon terminals of neighboring neurons instruct the fine-scale topography. Recent studies on activity-dependent topography in the Drosophila somatosensory system have revealed a role of neuronal activity in creating molecular differences among sensory neurons for establishing fine-scale topography, implicating a conserved principle. Here we review the findings in both Drosophila and vertebrates and propose an integrated model for fine-scale topography.

  12. Evaluation of abrasive waterjet produced titan surfaces topography by spectral analysis techniques

    Directory of Open Access Journals (Sweden)

    D. Kozak

    2012-01-01

    Full Text Available Experimental study of a titan grade 2 surface topography prepared by abrasive waterjet cutting is performed using methods of the spectral analysis. Topographic data are acquired by means of the optical profilometr MicroProf®FRT. Estimation of the areal power spectral density of the studied surface is carried out using the periodogram method combined with the Welch´s method. Attention is paid to a structure of the areal power spectral density, which is characterized by means of the angular power spectral density. This structure of the areal spectral density is linked to the fine texture of the surface studied.

  13. High-temperature phase transitions and domain structures of KLiSO{sub 4}. Studied by polarisation-optics, X-ray topography and liquid-crystal surface decoration

    Energy Technology Data Exchange (ETDEWEB)

    Scherf, Christian; Chung, Su Jin; Hahn, Theo; Klapper, Helmut [RWTH Aachen Univ. (Germany). Inst. fuer Kristallographie; Ivanov, Nicolay R. [Russian Academy of Sciences, Moscow (Russian Federation). Shubnikov Inst. of Crystallography

    2017-07-01

    The transitions between the room temperature phase III (space group P6{sub 3}) and the two high-temperature phases II (Pcmn) and I (P6{sub 3}/mmc) of KLiSO{sub 4} and the domain structures generated by them were investigated by high-temperature polarisation optics (birefringence) and room-temperature X-ray topography, optical activity and nematic-liquid-crystal (NLC) surface decoration. The transition from the polar hexagonal phase III into the centrosymmetric orthorhombic phase II at 708 K leads, due to the loss of the trigonal axis and the radial temperature gradient of the optical heating chamber used, to a roughly hexagonal arrangement of three sets of thin orthorhombic {110} lamelleae with angles of 60 (120 ) between them. The associated twin law ''reflection m{110}{sub orth}'' corresponds to the frequent growth twin m{10 anti 10}{sub hex} of phase III. The domains are easily ferroelastically switched. Upon further heating above 949 K into phase I (P6{sub 3}/mmc) all domains vanish. Upon cooling back into phase II the three domain states related by 60 (120 ) reflections m{110}{sub orth} re-appear, however (due to the higher thermal agitation at 949 K) with a completely different domain structure consisting of many small, irregularly arranged {110}{sub orth} domains. Particular attention is paid to the domain structure of the hexagonal room temperature phase III generated during the re-transition from the orthorhombic phase II. Curiously, from the expected three twin laws inversion anti 1, rotation 2 perpendicular to [001]{sub hex} and reflection m{10 anti 10}{sub hex} only the latter, which corresponds to the frequent growth twinning, has been found. Finally a short treatise of the structural relations of the KLiSO{sub 4} high-temperature polymorphs is given.

  14. Toroidal vortices over isolated topography in geophysical flows

    International Nuclear Information System (INIS)

    Koshel, Konstantin V; Ryzhov, Evgeny A; Zyryanov, Valery N

    2014-01-01

    This work deals with a model of a topographically trapped vortex appearing over isolated topography in a geophysical flow. The main feature of the study is that we pay special attention to the vertical structure of a topographically trapped vortex. The model considered allows one to study the vertical motion which is known not to be negligible in many cases. Given topography in the form of an isolated cylinder, and radial symmetry and stationarity of a uniform flow, in the linear approximation, we formulate a boundary value problem that determines all the components of the velocity field through a six-order differential operator, and nonincreasing boundary conditions at the center of the topography, and at infinity. The eigenvalues of the boundary value problem correspond to bifurcation points, in which the flow becomes unstable, hence non-negligible vertical velocities occur. We formulate a condition for the boundary value problem to have a discrete spectrum of these bifurcation points, and hence to be solvable. Conducting a series of test calculations, we show that the resulting vortex lies in the vicinity of topography, and can attain the distance up to half of the topography characteristic radius. (papers)

  15. Laser surface treatment and the resultant hierarchical topography of Ti grade 2 for biomedical application

    Energy Technology Data Exchange (ETDEWEB)

    Kuczyńska, Donata, E-mail: donatakuczynska@gmail.com [Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw (Poland); Kwaśniak, Piotr [Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw (Poland); Marczak, Jan [Military University of Technology, Institute of Optoelectronics, Warsaw (Poland); Bonarski, Jan [Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Cracow (Poland); Smolik, Jerzy [Institute for Sustainable Technology–National Research Institute, Radom (Poland); Garbacz, Halina [Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw (Poland)

    2016-12-30

    Highlights: • Presented surface modification results in multimodal topography. • Laser treatment creates roughness in a range from nano- to micrometers. • Multimodal topography promote protein adsorption. • Hybrid surface treatment results in a texture favorable for osteogenic passes. - Abstract: Modern prosthesis often have a complex structure, where parts of an implant have different functional properties. This gradient of functional properties means that local surface modifications are required. Method presented in this study was develop to functionalize prefabricated elements with original roughness obtained by conventional treatments used to homogenize and clean surface of titanium implants. Demonstrated methodology results in multimodal, periodic grooved topography with roughness in a range from nano- to micrometers. The modified surfaces were characterized in terms of shape, roughness, wettability, surface energy and chemical composition. For this purpose, the following methods were used: scanning electron microscopy, optical profilometry, atomic force microscopy, contact angle measurements and X-ray photoelectron spectroscopy. Protein adsorption studies were conducted to determine the potential biomedical application of proposed method. In order to estimate the intensity and way of the protein adsorption process on different titanium surfaces, XPS studies and AFM measurements were performed. The systematic comparison of surface states and their osseointegration tendency will be useful to evaluate suitability of presented method as an single step treatment for local surface functionalization of currently produced implantable devices.

  16. Fluorescence optical imaging and 3T-MRI for detection of synovitis in patients with rheumatoid arthritis in comparison to a composite standard of reference.

    Science.gov (United States)

    Thuermel, Klaus; Neumann, Jan; Jungmann, Pia M; Schäffeler, Christoph; Waldt, Simone; Heinze, Alexander; Beckmann, Alexander; Hauser, Christine; Hasenau, Anna-Lena; Wildgruber, Moritz; Clotten, Sigrun; Sievert, Matti; Haller, Bernhard; Woertler, Klaus; Harasser, Norbert; Rummeny, Ernst J; Meier, Reinhard

    2017-05-01

    To address whether Indocyanine Green (ICG) enhanced fluorescence optical imaging (FOI) is more sensitive than magnetic resonance imaging (MRI) in the detection of synovitis of the wrist and finger joints in rheumatoid arthritis and to analyze the performance of FOI depending on the grade of synovitis. Twenty patients with highly active rheumatoid arthritis (mean DAS28-ESR 5.25±1.0) and thirteen healthy volunteers underwent clinical examination, FOI and contrast-enhanced 3T-MRI. Joints were rated by three independent readers semiquantitatively (grade 0-3: no, low, moderate and high grade synovitis) and compared to a semiquantitative composite standard of reference (cSOR, grade 0-3) that incorporated clinical parameters, FOI and MRI results. 2.868 evaluations in 956 joints were performed. FOI had an overall sensitivity of 57.3% and a specificity of 92.1%, whereas MRI had a sensitivity of 89.2% and a specificity of 92.6%. The sensitivity of FOI increased with the degree of synovitis to 65.0% for moderate and severe synovitis (specificity 88.1%) and 76,3% for severe synovitis (specificity 80.5%). The performance of FOI decreased with the degree of synovitis with false negative results predominantly for mild (156/343, 45.5%) and moderate (160/343, 46.6%) synovitis and false positive FOI evaluations predominantly based on weak (grade 1) signals (133/163, 81,6%). FOI has a lower sensitivity than 3T-MRI in the detection of synovitis of the hand and finger joints. The diagnostic performance of FOI decreases with the degree of synovitis and with the strength of FOI signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Optical vortex scanning inside the Gaussian beam

    International Nuclear Information System (INIS)

    Masajada, J; Leniec, M; Augustyniak, I

    2011-01-01

    We discussed a new scanning method for optical vortex-based scanning microscopy. The optical vortex is introduced into the incident Gaussian beam by a vortex lens. Then the beam with the optical vortex is focused by an objective and illuminates the sample. By changing the position of the vortex lens we can shift the optical vortex position at the sample plane. By adjusting system parameters we can get 30 times smaller shift at the sample plane compared to the vortex lens shift. Moreover, if the range of vortex shifts is smaller than 3% of the beam radius in the sample plane the amplitude and phase distribution around the phase dislocation remains practically unchanged. Thus we can scan the sample topography precisely with an optical vortex

  18. Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

    Science.gov (United States)

    Jankov, Mirko R; Panagopoulou, Sophia I; Tsiklis, Nikolaos S; Hajitanasis, Georgos C; Aslanides, loannis M; Pallikaris, loannis G

    2006-04-01

    To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and

  19. Surface topography and contact mechanics of dry and wet human skin

    Directory of Open Access Journals (Sweden)

    Alexander E. Kovalev

    2014-08-01

    Full Text Available The surface topography of the human wrist skin is studied by using optical and atomic force microscopy (AFM methods. By using these techniques the surface roughness power spectrum is obtained. The Persson contact mechanics theory is used to calculate the contact area for different magnifications, for the dry and wet skin. The measured friction coefficient between a glass ball and dry and wet skin can be explained assuming that a frictional shear stress σf ≈ 13 MPa and σf ≈ 5 MPa, respectively, act in the area of real contact during sliding. These frictional shear stresses are typical for sliding on surfaces of elastic bodies. The big increase in friction, which has been observed for glass sliding on wet skin as the skin dries up, can be explained as result of the increase in the contact area arising from the attraction of capillary bridges. Finally, we demonstrated that the real contact area can be properly defined only when a combination of both AFM and optical methods is used for power spectrum calculation.

  20. MRI in Leber's hereditary optic neuropathy

    DEFF Research Database (Denmark)

    Matthews, Lucy; Enzinger, Christian; Fazekas, Franz

    2015-01-01

    BACKGROUND: Leber's hereditary optic neuropathy (LHON) and a multiple sclerosis (MS)-like illness appear to coexist 50 times more frequently than would be expected by chance. This association of LHON and MS (LMS) raises an important question about whether there could be a common pathophysiological...

  1. Similar prefrontal cortical activities between general fluid intelligence and visuospatial working memory tasks in preschool children as revealed by optical topography.

    Science.gov (United States)

    Kuwajima, Mariko; Sawaguchi, Toshiyuki

    2010-10-01

    General fluid intelligence (gF) is a major component of intellect in both adults and children. Whereas its neural substrates have been studied relatively thoroughly in adults, those are poorly understood in children, particularly preschoolers. Here, we hypothesized that gF and visuospatial working memory share a common neural system within the lateral prefrontal cortex (LPFC) during the preschool years (4-6 years). At the behavioral level, we found that gF positively and significantly correlated with abilities (especially accuracy) in visuospatial working memory. Optical topography revealed that the LPFC of preschoolers was activated and deactivated during the visuospatial working memory task and the gF task. We found that the spatio-temporal features of neural activity in the LPFC were similar for both the visuospatial working memory task and the gF task. Further, 2 months of training for the visuospatial working memory task significantly increased gF in the preschoolers. These findings suggest that a common neural system in the LPFC is recruited to improve the visuospatial working memory and gF in preschoolers. Efficient recruitment of this neural system may be important for good performance in these functions in preschoolers, and behavioral training using this system would help to increase gF at these ages.

  2. Effects of Topography-driven Micro-climatology on Evaporation

    Science.gov (United States)

    Adams, D. D.; Boll, J.; Wagenbrenner, N. S.

    2017-12-01

    The effects of spatial-temporal variation of climatic conditions on evaporation in micro-climates are not well defined. Current spatially-based remote sensing and modeling for evaporation is limited for high resolutions and complex topographies. We investigated the effect of topography-driven micro-climatology on evaporation supported by field measurements and modeling. Fourteen anemometers and thermometers were installed in intersecting transects over the complex topography of the Cook Agronomy Farm, Pullman, WA. WindNinja was used to create 2-D vector maps based on recorded observations for wind. Spatial analysis of vector maps using ArcGIS was performed for analysis of wind patterns and variation. Based on field measurements, wind speed and direction show consequential variability based on hill-slope location in this complex topography. Wind speed and wind direction varied up to threefold and more than 45 degrees, respectively for a given time interval. The use of existing wind models enables prediction of wind variability over the landscape and subsequently topography-driven evaporation patterns relative to wind. The magnitude of the spatial-temporal variability of wind therefore resulted in variable evaporation rates over the landscape. These variations may contribute to uneven crop development patterns observed during the late growth stages of the agricultural crops at the study location. Use of hill-slope location indexes and appropriate methods for estimating actual evaporation support development of methodologies to better define topography-driven heterogeneity in evaporation. The cumulative effects of spatially-variable climatic factors on evaporation are important to quantify the localized water balance and inform precision farming practices.

  3. X-ray diffraction topography. Stages and tendencies of development

    International Nuclear Information System (INIS)

    Shul'pina, I.L.

    2000-01-01

    The physical foundation of X-ray diffraction topography, its methods, the achievements in image theory, the stages of evolution were described in this review. It was found that modern topography is well along in development associated with the use of third-generation synchrotron radiation and with its adaptation to advance materials and problems of materials science. Some proposals about prospects for X-ray topography progress in the future have been made [ru

  4. Expressions for tidal conversion at seafloor topography using physical space integrals

    International Nuclear Information System (INIS)

    Schorghofer, Norbert

    2010-01-01

    The barotropic tide interacts with seafloor topography to generate internal gravity waves. Equations for streamfunction and power conversion are derived in terms of integrals over the topography in spatial coordinates. The slope of the topography does not need to be small. Explicit equations are derived up to second order in slope for general topography, and conversion by a bell-shaped topography is calculated analytically to this order. A concise formalism using Hilbert transforms is developed, the minimally converting topographic shape is discussed, and a numerical scheme for the evaluation of power conversion is designed that robustly deals with the singular integrand.

  5. Observation of self-assembled fluorescent beads by scanning near-field optical microscopy and atomic force microscopy

    International Nuclear Information System (INIS)

    Oh, Y.J.; Jo, W.; Kim, Min-Gon; Kyu Park, Hyun; Hyun Chung, Bong

    2006-01-01

    Optical response and topography of fluorescent latex beads both on flat self-assembled monolayer and on a micron-patterned surface with poly(dimethylsiloxane) are studied. Scanning near-field optical microscopy and atomic force microscopy were utilized together for detecting fluorescence and imaging topography of the patterned latex beads, respectively. As a result, the micro-patterned latex beads where a specific chemical binding occurred show a strong signal, whereas no signals are observed in the case of nonspecific binding. With fluorescein isothiocyanate (FITC), it is convenient to measure fluorescence signal from the patterned beads allowing us to monitor the small balls of fluorescent latex

  6. Smoking topography and abstinence in adult female smokers.

    Science.gov (United States)

    McClure, Erin A; Saladin, Michael E; Baker, Nathaniel L; Carpenter, Matthew J; Gray, Kevin M

    2013-12-01

    Preliminary evidence, within both adults and adolescents, suggests that the intensity with which cigarettes are smoked (i.e., smoking topography) is predictive of success during a cessation attempt. These reports have also shown topography to be superior compared to other variables, such as cigarettes per day, in the prediction of abstinence. The possibility that gender may influence this predictive relationship has not been evaluated but may be clinically useful in tailoring gender-specific interventions. Within the context of a clinical trial for smoking cessation among women, adult daily smokers completed a laboratory session that included a 1-hour ad libitum smoking period in which measures of topography were collected (N=135). Participants were then randomized to active medication (nicotine patch vs. varenicline) and abstinence was monitored for 4weeks. Among all smoking topography measures and all abstinence outcomes, a moderate association was found between longer puff duration and greater puff volume and continued smoking during the active 4-week treatment phase, but only within the nicotine patch group. Based on the weak topography-abstinence relationship among female smokers found in the current study, future studies should focus on explicit gender comparisons to examine if these associations are specific to or more robust in male smokers. © 2013 Elsevier Ltd. All rights reserved.

  7. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  8. Recent advances in engineering topography mediated antibacterial surfaces

    Science.gov (United States)

    Hasan, Jafar; Chatterjee, Kaushik

    2015-09-01

    The tendency of bacterial cells to adhere and colonize a material surface leading to biofilm formation is a fundamental challenge underlying many different applications including microbial infections associated with biomedical devices and products. Although, bacterial attachment to surfaces has been extensively studied in the past, the effect of surface topography on bacteria-material interactions has received little attention until more recently. We review the recent progress in surface topography based approaches for engineering antibacterial surfaces. Biomimicry of antibacterial surfaces in nature is a popular strategy. Whereas earlier endeavors in the field aimed at minimizing cell attachment, more recent efforts have focused on developing bactericidal surfaces. However, not all such topography mediated bactericidal surfaces are necessarily cytocompatible thus underscoring the need for continued efforts for research in this area for developing antibacterial and yet cytocompatible surfaces for use in implantable biomedical applications. This mini-review provides a brief overview of the current strategies and challenges in the emerging field of topography mediated antibacterial surfaces.

  9. Silk Film Topography Directs Collective Epithelial Cell Migration

    Science.gov (United States)

    Rosenblatt, Mark I.

    2012-01-01

    The following study provides new insight into how surface topography dictates directed collective epithelial cell sheet growth through the guidance of individual cell movement. Collective cell behavior of migrating human corneal limbal-epithelial cell sheets were studied on highly biocompatible flat and micro-patterned silk film surfaces. The silk film edge topography guided the migratory direction of individual cells making up the collective epithelial sheet, which resulted in a 75% increase in total culture elongation. This was due to a 3-fold decrease in cell sheet migration rate efficiency for movement perpendicular to the topography edge. Individual cell migration direction is preferred in the parallel approach to the edge topography where localization of cytoskeletal proteins to the topography’s edge region is reduced, which results in the directed growth of the collective epithelial sheet. Findings indicate customized biomaterial surfaces may be created to direct both the migration rate and direction of tissue epithelialization. PMID:23185573

  10. Percolation, statistical topography, and transport in random media

    International Nuclear Information System (INIS)

    Isichenko, M.B.

    1992-01-01

    A review of classical percolation theory is presented, with an emphasis on novel applications to statistical topography, turbulent diffusion, and heterogeneous media. Statistical topography involves the geometrical properties of the isosets (contour lines or surfaces) of a random potential ψ(x). For rapidly decaying correlations of ψ, the isopotentials fall into the same universality class as the perimeters of percolation clusters. The topography of long-range correlated potentials involves many length scales and is associated either with the correlated percolation problem or with Mandelbrot's fractional Brownian reliefs. In all cases, the concept of fractal dimension is particularly fruitful in characterizing the geometry of random fields. The physical applications of statistical topography include diffusion in random velocity fields, heat and particle transport in turbulent plasmas, quantum Hall effect, magnetoresistance in inhomogeneous conductors with the classical Hall effect, and many others where random isopotentials are relevant. A geometrical approach to studying transport in random media, which captures essential qualitative features of the described phenomena, is advocated

  11. Gravity Terrain Effect of the Seafloor Topography in Taiwan

    Directory of Open Access Journals (Sweden)

    Lun-Tao Tong Tai-Rong Guo

    2007-01-01

    Full Text Available Gravity terrain correction is used to compensate for the gravitational effects of the topography residual to the Bouguer plate. The seafloor topography off the eastern offshore of Taiwan is extremely rugged, and the depth of the sea bottom could be greater than 5000 m. In order to evaluate the terrain effect caused by the seafloor topography, a modern computer algorithm is used to calculate the terrain correction based on the digital elevation model (DEM.

  12. CT of second branchial cleft cysts and fistula: comparison with MRI in three cases

    Energy Technology Data Exchange (ETDEWEB)

    Schepper, A.M.A. de; Monheim, P.; Degryse, H.R.; Van de Heyning, P.

    1988-01-01

    Second branchial cleft cyst (SBCC) is a relatively common disease. Over a period of 18 months we have evaluated 11 patients with SBCC. Based on CT-findings all SBCC were correctly diagnosed as well in their uncomplicated as in their complicated (infected) presentation. A second branchial cleft fistula evaluated both by fistulography and CT-fistulography illustrates the anatomy of the cervical sinus and the potential topography of SBCC. Three cases were also evaluated by MRI and in two cases T1 calculation of aspirated cyst fluid was performed; preliminary results are reported.

  13. Study on cerebral activation areas during repetition with functional MRI in normal adults

    International Nuclear Information System (INIS)

    Koseki, Yohju

    2009-01-01

    For cerebral activation of speech areas in functional MRI (f-MRI) study, the usefulness of an optical microphone, which made it possible to perform task repetition at real time during scanning, was examined. Subjects were 25 healthy adults (mean age, 27.1±5.6 years), who consisted of 15 right-handed and 10 left-handed or ambidextrous persons. Tasks comprised repetition of monosyllables, non-words, words and sentences. The repetition tasks were covertly performed during scanning of f-MRI by using an optical microphone. In both the right-handed and non-right-handed groups, activations in the left superior temporal gyrus (sensory speech area) were most frequently observed during all of the tasks. In the right-handed group, activations in the left inferior frontal (motor speech area) and superior temporal gyri were significantly more often observed than those in the right inferior frontal and superior temporal gyri. From an assessment of the laterality index (LI), left-side dominant activation was frequently seen in most of the cerebral regions including sensory and motor speech areas, although right-side and bilateral dominant activations were observed in a few cases. In both groups, activations in regions associated with sensory speech were significantly more often seen than those in regions associated with motor speech. The present predominant activations in regions involved in sensory speech indicate that the optical microphone is useful in f-MRI studies using task repetition. (author)

  14. Multifocal visual evoked potential in optic neuritis, ischemic optic neuropathy and compressive optic neuropathy

    Science.gov (United States)

    Jayaraman, Manju; Gandhi, Rashmin Anilkumar; Ravi, Priya; Sen, Parveen

    2014-01-01

    Purpose: To investigate the effect of optic neuritis (ON), ischemic optic neuropathy (ION) and compressive optic neuropathy (CON) on multifocal visual evoked potential (mfVEP) amplitudes and latencies, and to compare the parameters among three optic nerve disorders. Materials and Methods: mfVEP was recorded for 71 eyes of controls and 48 eyes of optic nerve disorders with subgroups of optic neuritis (ON, n = 21 eyes), ischemic optic neuropathy (ION, n = 14 eyes), and compressive optic neuropathy (CON, n = 13 eyes). The size of defect in mfVEP amplitude probability plots and relative latency plots were analyzed. The pattern of the defect in amplitude probability plot was classified according to the visual field profile of optic neuritis treatment trail (ONTT). Results: Median of mfVEP amplitude (log SNR) averaged across 60 sectors were reduced in ON (0.17 (0.13-0.33)), ION (0.14 (0.12-0.21)) and CON (0.21 (0.14-0.30)) when compared to controls. The median mfVEP relative latencies compared to controls were significantly prolonged in ON and CON group of 10.53 (2.62-15.50) ms and 5.73 (2.67-14.14) ms respectively compared to ION group (2.06 (-4.09-13.02)). The common mfVEP amplitude defects observed in probability plots were diffuse pattern in ON, inferior altitudinal defect in ION and temporal hemianopia in CON eyes. Conclusions: Optic nerve disorders cause reduction in mfVEP amplitudes. The extent of delayed latency noted in ischemic optic neuropathy was significantly lesser compared to subjects with optic neuritis and compressive optic neuropathy. mfVEP amplitudes can be used to objectively assess the topography of the visual field defect. PMID:24088641

  15. Fully automated MRI-guided robotics for prostate brachytherapy

    International Nuclear Information System (INIS)

    Stoianovici, D.; Vigaru, B.; Petrisor, D.; Muntener, M.; Patriciu, A.; Song, D.

    2008-01-01

    The uncertainties encountered in the deployment of brachytherapy seeds are related to the commonly used ultrasound imager and the basic instrumentation used for the implant. An alternative solution is under development in which a fully automated robot is used to place the seeds according to the dosimetry plan under direct MRI-guidance. Incorporation of MRI-guidance creates potential for physiological and molecular image-guided therapies. Moreover, MRI-guided brachytherapy is also enabling for re-estimating dosimetry during the procedure, because with the MRI the seeds already implanted can be localised. An MRI compatible robot (MrBot) was developed. The robot is designed for transperineal percutaneous prostate interventions, and customised for fully automated MRI-guided brachytherapy. With different end-effectors, the robot applies to other image-guided interventions of the prostate. The robot is constructed of non-magnetic and dielectric materials and is electricity free using pneumatic actuation and optic sensing. A new motor (PneuStep) was purposely developed to set this robot in motion. The robot fits alongside the patient in closed-bore MRI scanners. It is able to stay fully operational during MR imaging without deteriorating the quality of the scan. In vitro, cadaver, and animal tests showed millimetre needle targeting accuracy, and very precise seed placement. The robot tested without any interference up to 7T. The robot is the first fully automated robot to function in MRI scanners. Its first application is MRI-guided seed brachytherapy. It is capable of automated, highly accurate needle placement. Extensive testing is in progress prior to clinical trials. Preliminary results show that the robot may become a useful image-guided intervention instrument. (author)

  16. ATM Coastal Topography-Mississippi, 2001

    Science.gov (United States)

    Nayegandhi, Amar; Yates, Xan; Brock, John C.; Sallenger, A.H.; Klipp, Emily S.; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of lidar-derived first-surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of the Mississippi coastline, from Lakeshore to Petit Bois Island, acquired September 9-10, 2001. The datasets are made available for use as a management tool to research scientists and natural-resource managers. An innovative scanning lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning lidar system that measures high-resolution topography of the land surface and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser-ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of lidar data in an interactive or batch mode. Modules for presurvey flight-line definition, flight-path plotting, lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant return within each waveform. ALPS

  17. ATM Coastal Topography-Alabama 2001

    Science.gov (United States)

    Nayegandhi, Amar; Yates, Xan; Brock, John C.; Sallenger, A.H.; Bonisteel, Jamie M.; Klipp, Emily S.; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of Lidar-derived first surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of the Alabama coastline, acquired October 3-4, 2001. The datasets are made available for use as a management tool to research scientists and natural resource managers. An innovative scanning Lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning Lidar system that measures high-resolution topography of the land surface, and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of Lidar data in an interactive or batch mode. Modules for pre-survey flight line definition, flight path plotting, Lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant return within each waveform. ALPS is routinely used to create maps that

  18. Interferometer for measuring the dynamic surface topography of a human tear film

    Science.gov (United States)

    Primeau, Brian C.; Greivenkamp, John E.

    2012-03-01

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. Following a blink, the tear film quickly smoothes and starts to become irregular after 10 seconds. This irregularity can affect comfort and vision quality. An in vivo method of characterizing dynamic tear films has been designed based upon a near-infrared phase-shifting interferometer. This interferometer continuously measures light reflected from the tear film, allowing sub-micron analysis of the dynamic surface topography. Movies showing the tear film behavior can be generated along with quantitative metrics describing changes in the tear film surface. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or corneal topography and provides better sensitivity and resolution than shearing interferometry methods. The interferometer design is capable of identifying features in the tear film much less than a micron in height with a spatial resolution of about ten microns over a 6 mm diameter. This paper presents the design of the tear film interferometer along with the considerations that must be taken when designing an interferometer for on-eye diagnostics. Discussions include eye movement, design of null optics for a range of ocular geometries, and laser emission limits for on-eye interferometry.

  19. Spectral analysis of the gravity and topography of Mars

    Science.gov (United States)

    Bills, Bruce G.; Frey, Herbert V.; Kiefer, Walter S.; Nerem, R. Steven; Zuber, Maria T.

    1993-01-01

    New spherical harmonic models of the gravity and topography of Mars place important constraints on the structure and dynamics of the interior. The gravity and topography models are significantly phase coherent for harmonic degrees n less than 30 (wavelengths greater than 700 km). Loss of coherence below that wavelength is presumably due to inadequacies of the models, rather than a change in behavior of the planet. The gravity/topography admittance reveals two very different spectral domains: for n greater than 4, a simple Airy compensation model, with mean depth of 100 km, faithfully represents the observed pattern; for degrees 2 and 3, the effective compensation depths are 1400 and 550 km, respectively, strongly arguing for dynamic compensation at those wavelengths. The gravity model has been derived from a reanalysis of the tracking data for Mariner 9 and the Viking Orbiters, The topography model was derived by harmonic analysis of the USGS digital elevation model of Mars. Before comparing gravity and topography for internal structure inferences, we must ensure that both are consistently referenced to a hydrostatic datum. For the gravity, this involves removal of hydrostatic components of the even degree zonal coefficients. For the topography, it involves adding the degree 4 equipotential reference surface, to get spherically referenced values, and then subtracting the full degree 50 equipotential. Variance spectra and phase coherence of orthometric heights and gravity anomalies are addressed.

  20. Multi-source least-squares reverse time migration with topography

    KAUST Repository

    Zhang, Dongliang; Schuster, Gerard T.; Zhan, Ge

    2013-01-01

    We demonstrate an accurate method for calculating LSM images from data recorded on irregular topography. Our results with both the Marmousi and Foothill models with steep topography suggest the effectiveness of this method.

  1. Multi-source least-squares reverse time migration with topography

    KAUST Repository

    Zhang, Dongliang

    2013-09-22

    We demonstrate an accurate method for calculating LSM images from data recorded on irregular topography. Our results with both the Marmousi and Foothill models with steep topography suggest the effectiveness of this method.

  2. Topography of the inferior alveolar nerve in relation to cystic processes of the mandible in dental MRI

    International Nuclear Information System (INIS)

    Kress, B.; Stippich, C.; Sartor, K.

    2003-01-01

    Purpose: Cystic processes are changing the course of the inferior alveolar nerve in the mandible. This study evaluates the possibility of demonstrating the relationship between space-occupying processes and the course of the neurovascular bundle. Materials and Methods: Thirteen patients with cystic processes in the mandible (9 keratocystic lesions, 1 eosinophilic granuloma, 1 plasmocytoma, 2 adamantinomas) were examined by MRI (1.5-T magnet, 8-cm surface coil, PD-gradient-echo-sequences in sagittal and coronal orientation, without enhancement) and the results retrospectively evaluated. Results: The entire course of the nerve could be delineated in all patients. In six patients with minor cystic processes, the nerve was identified in both sagittal and coronal orientation. In seven patients with major cystic lesions, only parts of the nerve were detected in either image orientation, but the nerve could be visualized in its entire length by evaluating coronal and sagittal images side by side. Conclusion: It is possible to delineate the inferior alveolar nerve in its entirety along pathologic mandibular lesions. For large cystic lesions, this requires the evaluation of both coronal and sagittal sections of multidirectional MRI. (orig.) [de

  3. Value of Cine-MRI sequences before and after injection in the diagnosis of acute myocarditis.

    Science.gov (United States)

    Zidi, Asma; Zairi, Ihsen; Mzoughi, Khadija; Zakhama, Lilia; Kamoun, Ikram; Ben Halima, Afef; Ridene, Imen

    2016-11-01

    Cardiovascular magnetic resonance (CMR) has become the examination of choice in case of suspicion of acute myocarditis. Late gadolinium enhancement (LGE) imaging is very important to establish this diagnosis. Cine MRI sequences are useful for the study of the myocardial contractility.   The purpose is to estimate the value of cine MRI sequences before and after injection for the diagnosis of acute myocarditis compared with late gadolinium enhanced sequences. We prospectively included 40 patients having a high suspicion of acute myocarditis and examined using a 1.5 Tesla CMR. Cine MRI sequences before and after injection were performed. The protocol also include  T2-weighted  short- tau-inversion-recovery (STIR T2) fast spin echo MRI and LGE imaging eight minutes after injection with visual adjustment of inversion time. Delayed enhancement was found among 23 patients. Fifteen patients (65 %) presented a spontaneous hyper signal detected visually on Cine MRI sequences before injection and 11 patients (48 %) on STIR T2. The hyper signal on Cine MRI sequences after injection of gadolinium was the same topography that the late raising at 23 patients. In addition, we highlighted a significant difference between this hyper signal before injection and the left ventricle ejection fraction (p=0.022) as well as with the telesystolic volume of the left ventricle (LV) indexed by the body mass (p=0.039). Our study suggests that Cine MRI sequences after injection are of equal performance in the diagnosis of acute myocarditis as the LGE sequences and its contibution is important when we want to shorten the examination or when inversion time isn't optimal.

  4. MRI findings of temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Nakahara, Ichiro; Yin, Dali; Fukami, Masahiro; Kondo, Seiji; Takeuchi, Juji; Kanemoto, Kousuke; Sengoku, Akira; Kawai, Itsuo

    1992-01-01

    MRI findings were analyzed retrospectively in 46 patients with temporal lobe epilepsy in which the side of epileptogenic focus had been confirmed by EEG studies. T 1 - and T 2 -weighted images were obtained by the use of a 1.0 or 1.5 T superconducting-type MRI machine with a coronal scan perpendicular to the axis of the temporal horn of the lateral ventricle. Additional axial and sagittal scans were performed in some cases. The area of the hippocampal body was measured quantitatively using a computerized image-analysis system in 26 cases in which the hippocampus had been visualized with enough contrast on T 1 -weighted coronal images. Abnormal findings were observed in 31/46 (67%) cases. Hippocampal (HC) and temporal lobe (TL) atrophy were observed in 18/46 (39%) and 23/46 (50%) cases respectively, and the side of the atrophy corresponded with the side of the epileptogenic focus, as confirmed by EEG studies, with specificities of 89% and 74% respectively. A quantitative measurement of the area of the hippocampal body showed unilateral hippocampal atrophy more than 10% in 18/25 (69%) cases (10-25%: 10 cases, 25-50%: 7 cases, 50% 2 abnormality was observed in only 4 cases. Structural lesions were observed in 4 cases including an arachnoid cyst, an astrocytoma in amygdala, the Dandy-Walker syndrome, and tuberous sclerosis, using the more efficient imaging qualities than the CT scan. From these observations, it is apparant that superconducting MRI is extremely useful in the diagnosis of the epileptogenic topography of temporal lobe epilepsy. Particularly, hippocampal atrophy was found to correspond with the side of the epileptogenic focus on EEG with a high specificity; its quantitative evaluation could be one of the most important standards in detecting the operative indications for temporal lobe epilepsy. (author)

  5. Modeling surface topography of state-of-the-art x-ray mirrors as a result of stochastic polishing process: recent developments

    Science.gov (United States)

    Yashchuk, Valeriy V.; Centers, Gary; Tyurin, Yuri N.; Tyurina, Anastasia

    2016-09-01

    Recently, an original method for the statistical modeling of surface topography of state-of-the-art mirrors for usage in xray optical systems at light source facilities and for astronomical telescopes [Opt. Eng. 51(4), 046501, 2012; ibid. 53(8), 084102 (2014); and ibid. 55(7), 074106 (2016)] has been developed. In modeling, the mirror surface topography is considered to be a result of a stationary uniform stochastic polishing process and the best fit time-invariant linear filter (TILF) that optimally parameterizes, with limited number of parameters, the polishing process is determined. The TILF model allows the surface slope profile of an optic with a newly desired specification to be reliably forecast before fabrication. With the forecast data, representative numerical evaluations of expected performance of the prospective mirrors in optical systems under development become possible [Opt. Eng., 54(2), 025108 (2015)]. Here, we suggest and demonstrate an analytical approach for accounting the imperfections of the used metrology instruments, which are described by the instrumental point spread function, in the TILF modeling. The efficacy of the approach is demonstrated with numerical simulations for correction of measurements performed with an autocollimator based surface slope profiler. Besides solving this major metrological problem, the results of the present work open an avenue for developing analytical and computational tools for stitching data in the statistical domain, obtained using multiple metrology instruments measuring significantly different bandwidths of spatial wavelengths.

  6. Estimating continuous floodplain and major river bed topography mixing ordinal coutour lines and topographic points

    Science.gov (United States)

    Bailly, J. S.; Dartevelle, M.; Delenne, C.; Rousseau, A.

    2017-12-01

    Floodplain and major river bed topography govern many river biophysical processes during floods. Despite the grow of direct topographic measurements from LiDARS on riverine systems, it still room to develop methods for large (e.g. deltas) or very local (e.g. ponds) riverine systems that take advantage of information coming from simple SAR or optical image processing on floodplain, resulting from waterbodies delineation during flood up or down, and producing ordered coutour lines. The next challenge is thus to exploit such data in order to estimate continuous topography on the floodplain combining heterogeneous data: a topographic points dataset and a located but unknown and ordered contourline dataset. This article is comparing two methods designed to estimate continuous topography on the floodplain mixing ordinal coutour lines and continuous topographic points. For both methods a first estimation step is to value each contourline with elevation and a second step is next to estimate the continuous field from both topographic points and valued contourlines. The first proposed method is a stochastic method starting from multigaussian random-fields and conditional simualtion. The second is a deterministic method based on radial spline fonction for thin layers used for approximated bivariate surface construction. Results are first shown and discussed from a set of synoptic case studies presenting various topographic points density and topographic smoothness. Next, results are shown and discuss on an actual case study in the Montagua laguna, located in the north of Valparaiso, Chile.

  7. Studies on improvement of diagnosis of neurosurgical lesions by magnetic resonance imaging (MRI), 2; Advantages of MRI on diagnosis of parasellar lesions and comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Kotoyuki (Kagoshima Univ. (Japan). Faculty of Medicine)

    1989-05-01

    Findings of magnetic resonance (MRI) imaging in 46 patients with sellar or parasellar mass were reviewed and compared with those of concurrently available X-ray CT. Intrasellar contents, the hypothalamic pituitary region, adjacent brain stem, optic nerves, and the surrounding cerebrospinal fluid were clearly depicted on T1-weighted images. The cavernous sinus and blood vessels, including the Willis circle, were visualized on T2-weighted images. In detecting pituitary macroadenoma, MRI seemed to be the most userful modality, because it was superior to CT in identifying abnormal changes of the infundibulum, diaphragma sellae, cavernous sinus and optic chiasm. Macroadenoma of the pituitary gland was usually isointense to the normal cerebral cortex on T1- and T2-weighted images. T1- and T2-weighted relaxation times for pituitary adenoma were slightly prolonged. The normal pituitary gland was distinguishable from adenomatous tissues. For microadenoma, MRI failed to show lesions or erosion of the sellar floor. Craniopharyngioma, meningioma of the tuberculum sellae, hypothalamic tumor, such as glioma and germinoma, and the other parasellar masses were clearly visualized on MRI. MRI was superior to CT in detecting tumor and its involvement, but inferior in detecting presence of calcification. T1-weighted imaging was useful in identifing the presence of intratumoral hemorrhage. Cysts of craniopharyngioma had various appearances on T1-weighted images. High signal cyst intensity corresponded to a high cholesterol content or the presence of methemoglobin. MRI depicted empty sella. The intrasellar content had the same appearance as that of the cerebrospinal fluid space, and the flattened pituitary gland and pituitary stalk were detected on T1-weighted images. (N.K.).

  8. Elucidating Dynamical Processes Relevant to Flow Encountering Abrupt Topography (FLEAT)

    Science.gov (United States)

    2015-09-30

    Encountering Abrupt Topography (FLEAT) Bo Qiu Dept of Oceanography, University of Hawaii at Manoa 1000 Pope Rd. Honolulu, HI 96822 phone: (808) 956...c) to explore relevant dynamics by using both simplified models and OGCM output with realistic topography and surface boundary conditions...scale abyssal circulation, we propose to use the Hallberg Isopycnal Model (HIM). The HIM allows sloping isopycnals to interact with bottom topography

  9. 3D topography measurements on correlation cells—a new approach to forensic ballistics identifications

    International Nuclear Information System (INIS)

    Song, John; Chu, Wei; Tong, Mingsi; Soons, Johannes

    2014-01-01

    Based on three-dimensional (3D) topography measurements on correlation cells, the National Institute of Standards and Technology (NIST) has developed the ‘NIST Ballistics Identification System (NBIS)’ aimed at accurate ballistics identifications and fast ballistics evidence searches. The 3D topographies are divided into arrays of correlation cells to identify ‘valid correlation areas’ and eliminate ‘invalid correlation areas’ from the matching and identification procedure. A ‘congruent matching cells’ (CMC)’ method using three types of identification parameters of the paired correlation cells (cross correlation function maximum CCF max , spatial registration position in x–y and registration angle θ) is used for high accuracy ballistics identifications. ‘Synchronous processing’ is proposed for correlating multiple cell pairs at the same time to increase the correlation speed. The proposed NBIS can be used for correlations of both geometrical topographies and optical intensity images. All the correlation parameters and algorithms are in the public domain and subject to open tests. An error rate reporting procedure has been developed that can greatly add to the scientific support for the firearm and toolmark identification specialty, and give confidence to the trier of fact in court proceedings. The NBIS is engineered to employ transparent identification parameters and criteria, statistical models and correlation algorithms. In this way, interoperability between different ballistics identification systems can be more easily achieved. This interoperability will make the NBIS suitable for ballistics identifications and evidence searches with large national databases, such as the National Integrated Ballistic Information Network in the United States. (paper)

  10. 3D topography measurements on correlation cells—a new approach to forensic ballistics identifications

    Science.gov (United States)

    Song, John; Chu, Wei; Tong, Mingsi; Soons, Johannes

    2014-06-01

    Based on three-dimensional (3D) topography measurements on correlation cells, the National Institute of Standards and Technology (NIST) has developed the ‘NIST Ballistics Identification System (NBIS)’ aimed at accurate ballistics identifications and fast ballistics evidence searches. The 3D topographies are divided into arrays of correlation cells to identify ‘valid correlation areas’ and eliminate ‘invalid correlation areas’ from the matching and identification procedure. A ‘congruent matching cells’ (CMC)’ method using three types of identification parameters of the paired correlation cells (cross correlation function maximum CCFmax, spatial registration position in x-y and registration angle θ) is used for high accuracy ballistics identifications. ‘Synchronous processing’ is proposed for correlating multiple cell pairs at the same time to increase the correlation speed. The proposed NBIS can be used for correlations of both geometrical topographies and optical intensity images. All the correlation parameters and algorithms are in the public domain and subject to open tests. An error rate reporting procedure has been developed that can greatly add to the scientific support for the firearm and toolmark identification specialty, and give confidence to the trier of fact in court proceedings. The NBIS is engineered to employ transparent identification parameters and criteria, statistical models and correlation algorithms. In this way, interoperability between different ballistics identification systems can be more easily achieved. This interoperability will make the NBIS suitable for ballistics identifications and evidence searches with large national databases, such as the National Integrated Ballistic Information Network in the United States.

  11. Nanotubular topography enhances the bioactivity of titanium implants.

    Science.gov (United States)

    Huang, Jingyan; Zhang, Xinchun; Yan, Wangxiang; Chen, Zhipei; Shuai, Xintao; Wang, Anxun; Wang, Yan

    2017-08-01

    Surface modification on titanium implants plays an important role in promoting mesenchymal stem cell (MSC) response to enhance osseointegration persistently. In this study, nano-scale TiO 2 nanotube topography (TNT), micro-scale sand blasted-acid etched topography (SLA), and hybrid sand blasted-acid etched/nanotube topography (SLA/TNT) were fabricated on the surfaces of titanium implants. Although the initial cell adherence at 60 min among TNT, SLA and TNT/SLA was not different, SLA and SLA/TNT presented to be rougher and suppressed the proliferation of MSC. TNT showed hydrophilic surface and balanced promotion of cellular functions. After being implanted in rabbit femur models, TNT displayed the best osteogenesis inducing ability as well as strong bonding strength to the substrate. These results indicate that nano-scale TNT provides favorable surface topography for improving the clinical performance of endosseous implants compared with micro and hybrid micro/nano surfaces, suggesting a promising and reliable surface modification strategy of titanium implants for clinical application. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Neurosyphilis Presenting as Asymptomatic Optic Perineuritis

    Directory of Open Access Journals (Sweden)

    Sarah E. Parker

    2012-01-01

    Full Text Available Introduction. Syphilis is a sexually transmitted disease that is known as “the great imitator” due to its wide variety of clinical presentations, including ocular disorders. There has been an increase in the rate of syphilis in the United States, especially in persons with HIV. We report a case of optic perineuritis in an asymptomatic male secondary to central nervous system (CNS syphilis. Case Report. A 41-year-old man was found to have bilateral disc edema on a routine exam. Brain MRI was unremarkable, and lumbar puncture revealed a normal opening pressure, with an elevated cerebrospinal fluid white cell count. Orbit MRI showed optic nerve sheath expansion and enhancement, consistent with optic perineuritis. He tested positive for syphilis based on serum RPR and FTA-ABS. Conclusion. Ophthalmologic findings, including disc edema, may be the presenting features of CNS syphilis. Even in asymptomatic persons, perineuritis should be considered early, as diagnosis and treatment are imperative given the progressive nature of the disease.

  13. Preliminary results of an examination of electronic cigarette user puff topography: the effect of a mouthpiece-based topography measurement device on plasma nicotine and subjective effects.

    Science.gov (United States)

    Spindle, Tory R; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas

    2015-02-01

    Electronic cigarettes (ECIGs) heat a nicotine-containing solution; the resulting aerosol is inhaled by the user. Nicotine delivery may be affected by users' puffing behavior (puff topography), and little is known about the puff topography of ECIG users. Puff topography can be measured using mouthpiece-based computerized systems. However, the extent to which a mouthpiece influences nicotine delivery and subjective effects in ECIG users is unknown. Plasma nicotine concentration, heart rate, and subjective effects were measured in 13 experienced ECIG users who used their preferred ECIG and liquid (≥ 12 mg/ml nicotine) during 2 sessions (with or without a mouthpiece). In both sessions, participants completed an ECIG use session in which they were instructed to take 10 puffs with 30-second inter-puff intervals. Puff topography was recorded in the mouthpiece condition. Almost all measures of the effects of ECIG use were independent of topography measurement. Collapsed across session, mean plasma nicotine concentration increased by 16.8 ng/ml, and mean heart rate increased by 8.5 bpm (ps topography measurement equipment, ECIG-using participants took larger and longer puffs with lower flow rates. In experienced ECIG users, measuring ECIG topography did not influence ECIG-associated nicotine delivery or most measures of withdrawal suppression. Topography measurement systems will need to account for the low flow rates observed for ECIG users. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Ekman effects in a rotating flow over bottom topography

    NARCIS (Netherlands)

    Zavala Sansón, L.; Heijst, van G.J.F.

    2002-01-01

    This paper presents a general two-dimensional model for rotating barotropic flows over topography. The model incorporates in a vorticity–stream function formulation both inviscid topography effects, associated with stretching and squeezing of fluid columns enforced by their motion over variable

  15. Quantitative OCT and MRI biomarkers for the differentiation of cartilage degeneration

    International Nuclear Information System (INIS)

    Nebelung, Sven; Brill, Nicolai; Tingart, Markus; Jahr, Holger; Pufe, Thomas; Kuhl, Christiane; Truhn, Daniel

    2016-01-01

    To evaluate the usefulness of quantitative parameters obtained by optical coherence tomography (OCT) and magnetic resonance imaging (MRI) in the comprehensive assessment of human articular cartilage degeneration. Human osteochondral samples of variable degeneration (n = 45) were obtained from total knee replacements and assessed by MRI sequences measuring T1, T1ρ, T2 and T2* relaxivity and by OCT-based quantification of irregularity (OII, optical irregularity index), homogeneity (OHI, optical homogeneity index) and attenuation (OAI, optical attenuation index). Samples were also assessed macroscopically (Outerbridge classification) and histologically (Mankin classification) as grade-0 (Mankin scores 0-4)/grade-I (scores 5-8)/grade-II (scores 9-10)/grade-III (score 11-14). After data normalisation, differences between Mankin grades and correlations between imaging parameters were assessed using ANOVA and Tukey's post-hoc test and Spearman's correlation coefficients, respectively. Sensitivities and specificities in the detection of Mankin grade-0 were calculated. Significant degeneration-related increases were found for T2 and OII and decreases for OAI, while T1, T1ρ, T2* or OHI did not reveal significant changes in relation to degeneration. A number of significant correlations between imaging parameters and histological (sub)scores were found, in particular for T2 and OII. Sensitivities and specificities in the detection of Mankin grade-0 were highest for OHI/T1 and OII/T1ρ, respectively. Quantitative OCT and MRI techniques seem to complement each other in the comprehensive assessment of cartilage degeneration. Sufficiently large structural and compositional changes in the extracellular matrix may thus be parameterized and quantified, while the detection of early degeneration remains challenging. (orig.)

  16. Quantitative OCT and MRI biomarkers for the differentiation of cartilage degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Nebelung, Sven [Aachen University Hospital, Department of Orthopaedics, Aachen (Germany); Institute of Anatomy and Cell Biology, RWTH, Aachen (Germany); Brill, Nicolai [Fraunhofer Institute for Production Technology, Aachen (Germany); Tingart, Markus; Jahr, Holger [Aachen University Hospital, Department of Orthopaedics, Aachen (Germany); Pufe, Thomas [Institute of Anatomy and Cell Biology, RWTH, Aachen (Germany); Kuhl, Christiane; Truhn, Daniel [Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Aachen (Germany)

    2016-04-15

    To evaluate the usefulness of quantitative parameters obtained by optical coherence tomography (OCT) and magnetic resonance imaging (MRI) in the comprehensive assessment of human articular cartilage degeneration. Human osteochondral samples of variable degeneration (n = 45) were obtained from total knee replacements and assessed by MRI sequences measuring T1, T1ρ, T2 and T2* relaxivity and by OCT-based quantification of irregularity (OII, optical irregularity index), homogeneity (OHI, optical homogeneity index) and attenuation (OAI, optical attenuation index). Samples were also assessed macroscopically (Outerbridge classification) and histologically (Mankin classification) as grade-0 (Mankin scores 0-4)/grade-I (scores 5-8)/grade-II (scores 9-10)/grade-III (score 11-14). After data normalisation, differences between Mankin grades and correlations between imaging parameters were assessed using ANOVA and Tukey's post-hoc test and Spearman's correlation coefficients, respectively. Sensitivities and specificities in the detection of Mankin grade-0 were calculated. Significant degeneration-related increases were found for T2 and OII and decreases for OAI, while T1, T1ρ, T2* or OHI did not reveal significant changes in relation to degeneration. A number of significant correlations between imaging parameters and histological (sub)scores were found, in particular for T2 and OII. Sensitivities and specificities in the detection of Mankin grade-0 were highest for OHI/T1 and OII/T1ρ, respectively. Quantitative OCT and MRI techniques seem to complement each other in the comprehensive assessment of cartilage degeneration. Sufficiently large structural and compositional changes in the extracellular matrix may thus be parameterized and quantified, while the detection of early degeneration remains challenging. (orig.)

  17. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  18. MRI characteristics of neuromyelitis optica spectrum disorder An international update

    DEFF Research Database (Denmark)

    Kim, H. J.; Paul, F.; Lana-Peixoto, M. A.

    2015-01-01

    location without optic nerve and spinal cord involvement. Thus, characteristics of brain abnormalities in such patients have become of increased interest. In this regard, MRI has an increasingly important role in the differential diagnosis of NMO and its spectrum disorder (NMOSD), particularly from...... of manifestations. Brain MRI abnormalities in patients seropositive for anti-aquaporin-4 antibody are common and some may be relatively unique by virtue of localization and configuration. Some seropositive patients present with brain involvement during their first attack and/or continue to relapse in the same...

  19. Clinical Validation of Point-Source Corneal Topography in Keratoplasty

    NARCIS (Netherlands)

    Vrijling, A C L; Braaf, B.; Snellenburg, J.J.; de Lange, F.; Zaal, M.J.W.; van der Heijde, G.L.; Sicam, V.A.D.P.

    2011-01-01

    Purpose. To validate the clinical performance of point-source corneal topography (PCT) in postpenetrating keratoplasty (PKP) eyes and to compare it with conventional Placido-based topography. Methods. Corneal elevation maps of the anterior corneal surface were obtained from 20 post-PKP corneas using

  20. Assessing Mand Topography Preference When Developing a Functional Communication Training Intervention.

    Science.gov (United States)

    Kunnavatana, S Shanun; Wolfe, Katie; Aguilar, Alexandra N

    2018-05-01

    Functional communication training (FCT) is a common function-based behavioral intervention used to decrease problem behavior by teaching an alternative communication response. Therapists often arbitrarily select the topography of the alternative response, which may influence long-term effectiveness of the intervention. Assessing individual mand topography preference may increase treatment effectiveness and promote self-determination in the development of interventions. This study sought to reduce arbitrary selection of FCT mand topography by determining preference during response training and acquisition for two adults with autism who had no functional communication skills. Both participants demonstrated a clear preference for one mand topography during choice probes, and the preferred topography was then reinforced during FCT to reduce problem behavior and increase independent communication. The implications of the results for future research on mand selection during FCT are discussed.

  1. Visual stimulation, {sup 1}H MR spectroscopy and fMRI of the human visual pathways

    Energy Technology Data Exchange (ETDEWEB)

    Boucard, Christine C.; Cornelissen, Frans W. [University of Groningen, Laboratory for Experimental Ophthalmology, Postbus 30001, Groningen (Netherlands); University of Groningen, BCN Neuro-imaging Center, Postbus 196, Groningen (Netherlands); Mostert, Jop P.; Keyser, Jacques De [University Hospital Groningen, Department of Neurology, Groningen (Netherlands); Oudkerk, Matthijs; Sijens, Paul E. [University Hospital Groningen, Department of Radiology, Groningen (Netherlands)

    2005-01-01

    The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). {sup 1}H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were performed in four subjects at an echo time of 135 ms. Functional MRI (fMRI) was used to confirm the presence of activity in the visual cortex during the visual stimulation. Spectral maps of optical chiasm were of poor quality due to field disturbances caused by nearby large blood vessels and/or eye movements. The optic radiations and the occipital lobe did not show any significant MR spectral change upon visual stimulation, i.e., the peak areas of inositol, choline, creatine, glutamate and N-acetylaspartate were not affected. Reproducible lactate signals were not observed. fMRI confirmed the presence of strong activations in stimulated visual cortex. Prolonged visual stimulation did not cause significant changes in MR spectra. Any signal observed near the 1.33 ppm resonance frequency of the lactate methyl-group was artifactual, originating from lipid signals from outside the volume of interest (VOI). Previous claims about changes in lactate levels in the visual cortex upon visual stimulation may have been based on such erroneous observations. (orig.)

  2. Refining the ischemic penumbra with topography.

    Science.gov (United States)

    Thirugnanachandran, Tharani; Ma, Henry; Singhal, Shaloo; Slater, Lee-Anne; Davis, Stephen M; Donnan, Geoffrey A; Phan, Thanh

    2018-04-01

    It has been 40 years since the ischemic penumbra was first conceptualized through work on animal models. The topography of penumbra has been portrayed as an infarcted core surrounded by penumbral tissue and an extreme rim of oligemic tissue. This picture has been used in many review articles and textbooks before the advent of modern imaging. In this paper, we review our understanding of the topography of the ischemic penumbra from the initial experimental animal models to current developments with neuroimaging which have helped to further define the temporal and spatial evolution of the penumbra and refine our knowledge. The concept of the penumbra has been successfully applied in clinical trials of endovascular therapies with a time window as long as 24 h from onset. Further, there are reports of "good" outcome even in patients with a large ischemic core. This latter observation of good outcome despite having a large core requires an understanding of the topography of the penumbra and the function of the infarcted regions. It is proposed that future research in this area takes departure from a time-dependent approach to a more individualized tissue and location-based approach.

  3. Surface analysis of titanium dental implants with different topographies

    Directory of Open Access Journals (Sweden)

    Silva M.H. Prado da

    2000-01-01

    Full Text Available Cylindrical dental implants made of commercially pure titanium were analysed in four different surface finishes: as-machined, Al2O3 blasted with Al2O3 particles, plasma-sprayed with titanium beads and electrolytically coated with hydroxyapatite. Scanning electron microscopy (SEM with Energy Dispersive X-ray Analysis (EDX revealed the topography of the surfaces and provided qualitative results of the chemical composition of the different implants. X-ray Photoelectron Spectroscopy (XPS was used to perform chemical analysis on the surface of the implants while Laser Scanning Confocal Microscopy (LSM produced topographic maps of the analysed surfaces. Optical Profilometry was used to quantitatively characterise the level of roughness of the surfaces. The implant that was plasma-sprayed and the hydroxyapatite coated implant showed the roughest surface, followed by the implant blasted with alumina and the as-machined implant. Some remnant contamination from the processes of blasting, coating and cleaning was detected by XPS.

  4. Description of two-process surface topography

    International Nuclear Information System (INIS)

    Grabon, W; Pawlus, P

    2014-01-01

    After two machining processes, a large number of surface topography measurements were made using Talyscan 150 stylus measuring equipment. The measured samples were divided into two groups. The first group contained two-process surfaces of random nature, while the second group used random-deterministic textures of random plateau parts and portions of deterministic valleys. For comparison, one-process surfaces were also analysed. Correlation and regression analysis was used to study the dependencies among surface texture parameters in 2D and 3D systems. As the result of this study, sets of parameters describing multi-process surface topography were obtained for two-process surfaces of random and of random-deterministic types. (papers)

  5. SU-F-P-26: Study of Radiation Dose Evaluation for Organs at Risk Using MRI in Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gong, G; Guo, Y; Yin, Y [Shandong Cancer Hospital and Institute, Jinan, Shandong (China)

    2016-06-15

    Purpose: To study the contour and dosimetric feature of organs at risk (OARs) applying magnetic resonance imaging (MRI) images in intensity modulated radiation therapy (IMRT) of nasopharyngeal carcinoma (NPC) compared to computed tomography (CT) images. Methods: 35 NPC patients was selected into this trail. CT simulation with non-contrast and contrast enhanced scan, MRI simulation with non-contrast and contrast enhanced T1, T2 and diffusion weighted imaging were achieved sequentially. And the OARs were contoured on the CT and MRI images after rigid registration respectively. 9 beams IMRT plan with equal division angle were designed for every patients, and the prescription dose for tumor target was set as 72Gy (2.4Gy/ fration). The boundary display, volume and dose-volume indices of each organ were compared between on MRI and CT images. Results: Compared to CT, MRI showed clearer boundary of brainstem, spinal cord, the deep lobe of Parotid gland and the optical nerve in canal. MRI images increase the volume of lens, optical nerve, while reducing the volume of eye slightly, and the maximum dose of lens, the mean dose of eyes and optical raised in different percentage, while there was no statistical differences were found. The left and right parotid volume on MRI increased by 7.07%, 8.13%, and the mean dose raised by 14.95% (4.01Gy), 18.76% (4.95Gy) with statistical significant difference (p<0.05). The brainstem volume reduced by 9.33% (p<0.05), and the dose of 0.1cm3 volume (D0.1cm3) reduced by mean 8.46% (4.32Gy), and D0.1cm3 of spinal cord increased by 1.5Gy on MRI. Conclusion: It is credible to evaluate the radiation dose of lens, eye and the spinal cord, while it should be necessary to evaluate the dose of brainstem, parotid and the optical nerve applying MRI images sometime, it will be more meaningful for these organs with high risk of radiation injury.

  6. MRI of esophagus. N staging and more.

    International Nuclear Information System (INIS)

    Krupski-Berdien, G.

    2007-01-01

    Esophageal disease is common. Fluoroscopy with or without fast cine-sequences is able to depict swallowing dynamics precisely and therefore is used in cases with swallowing disturbance, achalasia or diverticula etc. It is performed in addition to primary endoscopy. There is no evidence based indication for MRI in these settings as it is not to rule out postsurgical fistula and incompetence. Endoscopy and endosonography are gold standard for the depiction as well as staging of esophageal tumors hence differentiation of the esophageal wall layers and detection of suspicious lymph nodes is possible. And from both, biopsies may be taken. New techniques as OCT (optical coherence tomography) can demonstrate in situ carcinoma and therefore helps to decide for limited treatments as mucosectomy. For today multimodular treatment strategies in esophageal carcinoma the T-stage will lead to the treatment decision whereas the nodal-stage will give information about the prognosis. As a matter of fact endoscopy is unable to pass a stenosis esophageal tumor in up to 50% of the cases and will therefore not be able to give precise information on both T- and N-stage resulting in a good indication for MRI. Fetal MRI of the chest is a new topic in which MRI seems to be superior to ultrasonography. (orig.) [de

  7. Brain MRI findings in infants with primary congenital glaucoma

    International Nuclear Information System (INIS)

    Dai, A. Ibrahym; Saygili, O.

    2007-01-01

    Congenital glaucoma appears in the first months of life, eventually at birth. Isolated congenital glaucoma is characterized by minor malformations of the irido-corneal angle of the anterior chamber of the eye. Clinical manifestations include tearing, photophobia and enlargement of the globe appearing in the first months of life. Imaging technology such as optical coherence tomography and measurement of central corneal thickness may play an important role in the assessment of children with suspected or known glaucoma. However, no MRI findings of the CNS in patients with primary congenital glaucoma (PCG) were reported in the literature. The purpose of this study was to investigate MRI findings of the brain in infants with PCG. We reviewed the radiological and histopathological and clinical characteristics of infants with primary congenital glaucoma. The records of 17 patients with PCG were reviewed and the MRIs of the brain and associated manifestations were analyzed. Three patients with PCG had abnormal MRI findings suggesting agenesis of the corpus callosum. Two infants had delayed myelinization of the brain. Significant abnormal optic nerve excavation and increased corneal diameters in 2 patients with delayed myelinization may suggest that intraocular pressure can be more striking and more severe, revealing a close relationship with PCG and abnormal myelinization in white matter. Studies with more patients are needed to confirm these results. (author)

  8. Morphometric MRI changes in intracranial hypertension due to cerebral venous thrombosis: a retrospective imaging study

    International Nuclear Information System (INIS)

    Dong, Cheng; Zheng, Ying-mei; Li, Xiao-li; Wang, He-xiang; Hao, Da-peng; Nie, Pei; Pang, Jing; Xu, Wen-jian

    2016-01-01

    Aim: To evaluate whether some magnetic resonance imaging (MRI) signs suggesting idiopathic intracranial hypertension (IIH) could also be found in intracranial hypertension (IH) due to cerebral venous thrombosis (CVT) and to assess their possible contribution to diagnosing this disorder. Materials and methods: Thirty-one patients with IH due to CVT were evaluated prospectively using MRI. A group of 33 age- and sex-matched healthy volunteers served as controls. The optic nerve and sheath, pituitary gland, and ventricles were assessed. The prevalence of each imaging feature was compared between the two groups. Results: Optic nerve sheath (ONS) dilatation and decreased pituitary gland height were the most valid signs suggesting IH in CVT patients: sensitivity 70.97% and 87.1%, respectively; specificity 96.97% and 72.73%, respectively; area under the curve 0.840 and 0.809, respectively. The MRI finding that showed the strongest association with IH in CVT patients was ONS dilatation (odds ratio 78.5). Conclusions: The combination of T1-weighted volumetric MRI and magnetic resonance venography could be helpful for diagnosing IH with CVT. Abnormalities of the ONS and the pituitary gland were reliable diagnostic signs for IH due to CVT. - Highlights: • We compared the prevalence of MRI imaging features between IH patients due to CVT and healthy volunteers. • Several MRI imaging features occur more frequently in IH patients due to CVT. • Abnormalities of the ONS and the pituitary gland were reliable diagnostic signs for IH due to CVT.

  9. Topography measurements for determining the decay factors in surface replication

    International Nuclear Information System (INIS)

    Song, J; Zheng, A; Vorburger, T V; Rubert, P

    2008-01-01

    The electro-forming technique is used at National Institute of Standards and Technology (NIST) for the production of standard reference material (SRM) 2461 standard casings to support nationwide ballistics measurement traceability and measurement quality control in the US. In order to ensure that the SRM casings are produced with virtually the same surface topography, it is necessary to test the decay factors of the replication process. Twenty-six replica casings are replicated from the same master casing for the decay factor tests. The NIST topography measurement system is used for measurements and correlations of surface topography. The topography decays are quantified by the cross-correlation function maximum CCF max . Based on the test, it is expected that 256 SRM casings can be replicated from the same master with CCF max values higher than 95%

  10. Influence of surface topography on the sputtering yields of silver

    International Nuclear Information System (INIS)

    Pan Jisheng; Wang Zhenxia; Tao Zhenlan; Zhang Jiping

    1992-01-01

    The sputtering yields of silver have been measured as a function of the fluence of incident Ar + ions (27 keV) using the collector technique and RBS analysis. The irradiated surface was examined by scanning electron microscopy (SEM). It is shown that the sputtering yields of surfaces with topography are enhanced relative to smooth surfaces of silver, but the extent of the enhancement depends on the irradiation dose. The experimental results can be explained assuming that the surface topography and sputtering yield are a function of incident angle. It is obvious that the surface topography is an important factor to influence the sputtering yield. The term ''apparent sputtering yield'' has specifically been used when referring to the experimental sputtering yield of a surface with topography, to emphasize the difference with a smooth surface. (orig.)

  11. An integrated instrumental setup for the combination of atomic force microscopy with optical spectroscopy.

    Science.gov (United States)

    Owen, R J; Heyes, C D; Knebel, D; Röcker, C; Nienhaus, G U

    2006-07-01

    In recent years, the study of single biomolecules using fluorescence microscopy and atomic force microscopy (AFM) techniques has resulted in a plethora of new information regarding the physics underlying these complex biological systems. It is especially advantageous to be able to measure the optical, topographical, and mechanical properties of single molecules simultaneously. Here an AFM is used that is especially designed for integration with an inverted optical microscope and that has a near-infrared light source (850 nm) to eliminate interference between the optical experiment and the AFM operation. The Tip Assisted Optics (TAO) system consists of an additional 100 x 100-microm(2) X-Y scanner for the sample, which can be independently and simultaneously used with the AFM scanner. This allows the offset to be removed between the confocal optical image obtained with the sample scanner and the simultaneously acquired AFM topography image. The tip can be positioned exactly into the optical focus while the user can still navigate within the AFM image for imaging or manipulation of the sample. Thus the tip-enhancement effect can be maximized and it becomes possible to perform single molecule manipulation experiments within the focus of a confocal optical image. Here this is applied to simultaneous measurement of single quantum dot fluorescence and topography with high spatial resolution. (c) 2006 Wiley Periodicals, Inc.

  12. Correlation between three-dimentional surface topography and color stability of different nanofilled composites.

    Science.gov (United States)

    Öztürk, Elif; Güder, Gizem

    2015-01-01

    The aim of this study was to evaluate the 3-dimensional (3D) surface topography and color stability of four different resin composites after immersion in different soft-beverages. One hundred sixty disk-shaped specimens (diameter: 10 mm, and thickness: 2 mm) were made from four different resin composites (i.e., Filtek Z550, Tetric N-Ceram, Clearfil Majesty Esthetic, and Cavex Quadrant Universal LC). Each specimen was cured under mylar strips for 20 sec for both top and bottom surfaces. All of the specimens were stored in distilled water for 24 h at 37°C. Surface measurements were carried out using a noncontact 3D-optical-profilometer in terms of surface topography (Ra values). Color measurements of each specimen were performed with Vita Easy Shade system. All the measurements were performed at baseline and after 30 days of immersion in the selected soft-beverages (Redbull, Coca-Cola and Dimes-Lemonade). Control groups were stored in distilled water during the study. Ra values and color changes (ΔE values) of the groups were recorded. The data were statistically analyzed using a one way ANOVA and Tukey's post-hoc tests (SPSS 18.0). The tested soft-beverages in the present study caused color changes at a 30-day evaluation period for the tested resin composites (p composites was not influenced by the tested soft-beverages (p > 0.05). There was no significant interaction between the composite and beverage type on the Ra values of the resin composites (p > 0.05). No correlation was found between color stability and 3D surface topography of the resin composites. Color stability of resin composites may be affected by soft beverages. © Wiley Periodicals, Inc.

  13. Comparison of Alterations in the Surface Topographies of HyFlex CM and HyFlex EDM Nickel-titanium Files after Root Canal Preparation: A Three-dimensional Optical Profilometry Study.

    Science.gov (United States)

    Uslu, Gülşah; Özyürek, Taha; Yılmaz, Koray

    2018-01-01

    The aims of the present study were to examine the surface topographies of intact HyFlex CM and HyFlex EDM nickel-titanium files and to compare alterations in the surface topographies of these files after root canal preparation of severely curved canals of molar teeth. Eight HyFlex CM (25/.08) and 8 HyFlex EDM (25/.08) files were included in the present study. In total, 64 severely curved canals of molar teeth, with curvature angles ranging between 50° and 70°, were prepared with HyFlex CM and EDM (n = 32 in each group). Quantitative and qualitative analyses of the files' surface deformation were performed by using three-dimensional optical profilometry before and after root canal preparation. The data were analyzed with the Student t test at the 5% significant level by using SPSS 21.0 software. In the HyFlex EDM group, the qualitative evaluation revealed the presence of cracks and microcavities after use of the file for root canal preparation, whereas only minor surface deformation was observed in the HyFlex CM group. The average roughness, root mean square roughness, and peak to valley height values of the HyFlex EDM group were significantly higher than those of the HyFlex CM group before and after root canal preparation (P EDM group was not statistically significant (P > .5). Within the limitations of the present study, the HyFlex CM files showed significantly higher surface alterations compared with the HyFlex EDM files after the preparation of severely curved root canals. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. A rare case of bilateral optic nerve sheath meningioma

    Directory of Open Access Journals (Sweden)

    Somen Misra

    2014-01-01

    Full Text Available A 60-year-old female presented with gradual, painless, progressive diminution of vision, and progressive proptosis of left eye since 7 years. Ophthalmological examination revealed mild proptosis and total optic atrophy in the left eye. Magnetic resonance imaging (MRI and computed tomography (CT brain with orbit showed bilateral optic nerve sheath meningioma (ONSM involving the intracranial, intracanalicular, intraorbital part of the optic nerve extending up to optic chiasma and left cavernous sinus.

  15. Topography-guided photorefractive keratectomy for irregular astigmatism after small incision lenticule extraction.

    Science.gov (United States)

    Ivarsen, Anders; Hjortdal, Jesper Ø

    2014-06-01

    To report the outcome of topography-guided photorefractive keratectomy (PRK) after complicated small incision lenticule extraction (SMILE). Retrospective case series of 5 eyes with irregular topography and ghost images after complicated SMILE. All eyes received transepithelial topography-guided PRK. Two eyes were treated with 0.02% mitomycin C. Patients were examined after a minimum of 3 months with evaluation of uncorrected (UDVA) and corrected (CDVA) distance visual acuity, Pentacam tomography (Oculus Optikgeräte, Wetzlar, Germany), and whole-eye aberrometry. In 3 eyes, subjective symptoms were diminished and UDVA, CDVA, topography, and corneal wavefront aberrations were improved. The remaining 2 eyes developed significant haze with worsened topography and wavefront aberrations. One eye experienced a two-line reduction in CDVA. Eyes with haze development had not been treated with mitomycin C. Transepithelial topography-guided PRK may reduce visual symptoms after complicated SMILE if postoperative haze can be controlled. To reduce the risk of haze development, application of mitomycin C may be considered. Copyright 2014, SLACK Incorporated.

  16. Effect of surface topography and morphology on space charge packets in polyethylene

    International Nuclear Information System (INIS)

    Zhou Yuanxiang; Wang Yunshan; Sun Qinghua; Wang Ninghua

    2009-01-01

    Polyethylene (PE) is a major kind of internal insulating material. With great progresses of space charge measurement technologies in the last three decades, lots of researches are focused on space charge in PE. The heat pressing and annealing condition of polyethylene affect its morphology obviously. During the heat pressing, the surface of PE forms different surface topographies because of different substrate materials. Surface topography has great relation to the epitaxial crystallization layer and influences the space charge characteristic of PE dramatically. This paper studied the formation process of different surface topographies and their micrographic characters in low density polyethylene (LDPE). pulsed electro-acoustic (PEA) method was used to measure the space charge distribution of samples with different surface topographies and morphologies in LDPE. The effect of surface topography and morphology to space charge packet were studied. The surface topography has great influence on space charge packet polarity and morphology has influence on both movement speed rate and polarity of space charge packet.

  17. Diffuse Optical Tomography for Brain Imaging: Theory

    Science.gov (United States)

    Yuan, Zhen; Jiang, Huabei

    Diffuse optical tomography (DOT) is a noninvasive, nonionizing, and inexpensive imaging technique that uses near-infrared light to probe tissue optical properties. Regional variations in oxy- and deoxy-hemoglobin concentrations as well as blood flow and oxygen consumption can be imaged by monitoring spatiotemporal variations in the absorption spectra. For brain imaging, this provides DOT unique abilities to directly measure the hemodynamic, metabolic, and neuronal responses to cells (neurons), and tissue and organ activations with high temporal resolution and good tissue penetration. DOT can be used as a stand-alone modality or can be integrated with other imaging modalities such as fMRI/MRI, PET/CT, and EEG/MEG in studying neurophysiology and pathology. This book chapter serves as an introduction to the basic theory and principles of DOT for neuroimaging. It covers the major aspects of advances in neural optical imaging including mathematics, physics, chemistry, reconstruction algorithm, instrumentation, image-guided spectroscopy, neurovascular and neurometabolic coupling, and clinical applications.

  18. UV laser micromachining of ceramic materials: formation of columnar topographies

    International Nuclear Information System (INIS)

    Oliveira, V.; Vilar, R.; Conde, O.

    2001-01-01

    Laser machining is increasingly appearing as an alternative for micromachining of ceramics. Using ceramic materials using excimer lasers can result in smooth surfaces or in the formation of cone-like or columnar topography. Potential applications of cone-shaped or columnar surface topography include, for example, light trapping in anti-reflection coatings and improvement of adhesion bonding between ceramic materials. In this communication results of a comparative study of surface topography change during micromachining of several ceramic materials with different ablation behaviors are reported. (orig.)

  19. New nontoxic double information magnetic and fluorescent MRI agent

    Energy Technology Data Exchange (ETDEWEB)

    Kublickas, Augustinas; Rastenien, Loreta; Bloznelytė-Plėšnienė, Laima; Karalius, Nerijus [Liquid Crystals Laboratory, Institute of Science and Technology, Lithuanian University of Educational Sciences (Lithuania); Franckevinius, Marius [Institute of Physics, Center for Physical Sciences and Technology (Lithuania); Loudos, George [Technological Educational Institute of Athens (Greece); Fahmi, Amir [Materials Science, Rhein-Waal University of Applied Sciences (Germany); Vaisnoras, Rimas [Liquid Crystals Laboratory, Institute of Science and Technology, Lithuanian University of Educational Sciences (Lithuania)

    2015-05-18

    Today sensitivity of the MRI is not enough compared to the nuclear methods, such as positron emission tomography and single photon emission computed tomography. Challenging its extension to the nanometre scale could provide a powerful new tool for the nanosciences and nanomedicine. To achieve this potential, innovative new detection strategies are required to overcome the severe sensitivity limitations of conventional inductive detection techniques. In this regard, we perform embodiment of nanodiamonds in dendrimer matrix as additional fluorescent optical and magnetic (together with Gd (III)) imaging modalities of the MRI. New hybrid system composed of dendrimer-gadolinium Gd (III) - nanodiamond as a new contrast agent for MRI was studied. Poly(propilene-imine) PPI and poly(amidoamine) PAMAM dendrimers with fixed size of nanocavities will be used as host material to protect organism against the toxicity and also to increase relaxivity of contrast agent (resulting in the increases MRI resolution). Nanodiamond as biocompatible platform to functionalize the contrast agent will be used. This bimodal hybrid system enables to use smaller amount of the contrast agent and could permit the decrease of the lateral toxicity. This bimodal hybrid system as MRI agent is providing double information (magnetic and fluorescent) about the damaged cell.

  20. New nontoxic double information magnetic and fluorescent MRI agent

    International Nuclear Information System (INIS)

    Kublickas, Augustinas; Rastenien, Loreta; Bloznelytė-Plėšnienė, Laima; Karalius, Nerijus; Franckevinius, Marius; Loudos, George; Fahmi, Amir; Vaisnoras, Rimas

    2015-01-01

    Today sensitivity of the MRI is not enough compared to the nuclear methods, such as positron emission tomography and single photon emission computed tomography. Challenging its extension to the nanometre scale could provide a powerful new tool for the nanosciences and nanomedicine. To achieve this potential, innovative new detection strategies are required to overcome the severe sensitivity limitations of conventional inductive detection techniques. In this regard, we perform embodiment of nanodiamonds in dendrimer matrix as additional fluorescent optical and magnetic (together with Gd (III)) imaging modalities of the MRI. New hybrid system composed of dendrimer-gadolinium Gd (III) - nanodiamond as a new contrast agent for MRI was studied. Poly(propilene-imine) PPI and poly(amidoamine) PAMAM dendrimers with fixed size of nanocavities will be used as host material to protect organism against the toxicity and also to increase relaxivity of contrast agent (resulting in the increases MRI resolution). Nanodiamond as biocompatible platform to functionalize the contrast agent will be used. This bimodal hybrid system enables to use smaller amount of the contrast agent and could permit the decrease of the lateral toxicity. This bimodal hybrid system as MRI agent is providing double information (magnetic and fluorescent) about the damaged cell.

  1. The influence of surface topography on Kelvin probe force microscopy

    International Nuclear Information System (INIS)

    Sadewasser, S; Leendertz, C; Streicher, F; Lux-Steiner, M Ch

    2009-01-01

    Long-range electrostatic forces govern the imaging mechanism in electrostatic force microscopy as well as in Kelvin probe force microscopy. To improve the analysis of such images, simulations of the electrostatic field distribution have been performed in the past using a flat surface and a cone-shaped tip. However, the electrostatic field distribution between a tip and a sample depends strongly on the surface topography, which has been neglected in previous studies. It is therefore of general importance to study the influence of sample topography features on Kelvin probe force microscopy images, which we address here by performing finite element simulations. We show how the surface potential measurement is influenced by surface steps and surface grooves, considering potential variations in the form of a potential peak and a potential step. The influence of the topography on the measurement of the surface potential is found to be rather small compared to a typical experimental resolution. Surprisingly, in the case of a coinciding topography and potential step an improvement of the potential profile due to the inclusion of the topography is observed. Finally, based on the obtained results, suggestions for the realization of KPFM measurement are given.

  2. Understanding the mechanisms of solid-water reactions through analysis of surface topography.

    Science.gov (United States)

    Bandstra, Joel Z; Brantley, Susan L

    2015-12-01

    The topography of a reactive surface contains information about the reactions that form or modify the surface and, therefore, it should be possible to characterize reactivity using topography parameters such as surface area, roughness, or fractal dimension. As a test of this idea, we consider a two-dimensional (2D) lattice model for crystal dissolution and examine a suite of topography parameters to determine which may be useful for predicting rates and mechanisms of dissolution. The model is based on the assumption that the reactivity of a surface site decreases with the number of nearest neighbors. We show that the steady-state surface topography in our model system is a function of, at most, two variables: the ratio of the rate of loss of sites with two neighbors versus three neighbors (d(2)/d(3)) and the ratio of the rate of loss of sites with one neighbor versus three neighbors (d(1)/d(3)). This means that relative rates can be determined from two parameters characterizing the topography of a surface provided that the two parameters are independent of one another. It also means that absolute rates cannot be determined from measurements of surface topography alone. To identify independent sets of topography parameters, we simulated surfaces from a broad range of d(1)/d(3) and d(2)/d(3) and computed a suite of common topography parameters for each surface. Our results indicate that the fractal dimension D and the average spacing between steps, E[s], can serve to uniquely determine d(1)/d(3) and d(2)/d(3) provided that sufficiently strong correlations exist between the steps. Sufficiently strong correlations exist in our model system when D>1.5 (which corresponds to D>2.5 for real 3D reactive surfaces). When steps are uncorrelated, surface topography becomes independent of step retreat rate and D is equal to 1.5. Under these conditions, measures of surface topography are not independent and any single topography parameter contains all of the available mechanistic

  3. Spray-coatable negative photoresist for high topography MEMS applications

    International Nuclear Information System (INIS)

    Arnold, Markus; Haas, Sven; Schwenzer, Falk; Schwenzer, Gunther; Reuter, Danny; Geßner, Thomas; Voigt, Anja; Gruetzner, Gabi

    2017-01-01

    In microsystem technology, the lithographical processing of substrates with a topography is very important. Interconnecting lines, which are routed over sloped topography sidewalls from the top of the protecting wafer to the contact pads of the device wafer, are one example of patterning over a topography. For structuring such circuit paths, a photolithography process, and therefore a process for homogeneous photoresist coating, is required. The most flexible and advantageous way of depositing a homogeneous photoresist film over structures with high topography steps is spray-coating. As a pattern transfer process for circuit paths in cavities, the lift-off process is widely used. A negative resist, like ma-N (MRT) or AZnLOF (AZ) is favoured for lift-off processes due to the existing negative angle of the sidewalls. Only a few sprayable negative photoresists are commercially available. In this paper, the development of a novel negative resist spray-coating based on a commercially available single-layer lift-off resist for spin-coating, especially for the patterning of structures inside the cavity and on the cavity wall, is presented. A variety of parameters influences the spray-coating process, and therefore the patterning results. Besides the spray-coating tool and the parameters, the composition of the resist solution itself also influences the coating results. For homogeneous resist coverage over the topography of the substrate, different solvent combinations for diluting the resist solution, different chuck temperatures during the coating process, and also the softbake conditions, are all investigated. The solvent formulations and the process conditions are optimized with respect to the homogeneity of the resist coverage on the top edge of the cavities. Finally, the developed spray-coating process, the resist material and the process stability are demonstrated by the following applications: (i) lift-off, (ii) electroplating, (iii) the wet and (iv) the dry

  4. Optic neuropathy in a patient with pyruvate dehydrogenase deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Small, Juan E. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Gonzalez, Guido E. [Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Radiology, Boston, MA (United States); Clinica Alemana de Santiago, Departmento de Imagenes, Santiago (Chile); Nagao, Karina E.; Walton, David S. [Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Ophthalmology, Boston, MA (United States); Caruso, Paul A. [Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2009-10-15

    Pyruvate dehydrogenase (PDH) deficiency is a genetic disorder of mitochondrial metabolism. The clinical manifestations range from severe neonatal lactic acidosis to chronic neurodegeneration. Optic neuropathy is an uncommon clinical sequela and the imaging findings of optic neuropathy in these patients have not previously been described. We present a patient with PDH deficiency with bilateral decreased vision in whom MRI demonstrated bilateral optic neuropathy and chiasmopathy. (orig.)

  5. Optic neuropathy in a patient with pyruvate dehydrogenase deficiency

    International Nuclear Information System (INIS)

    Small, Juan E.; Gonzalez, Guido E.; Nagao, Karina E.; Walton, David S.; Caruso, Paul A.

    2009-01-01

    Pyruvate dehydrogenase (PDH) deficiency is a genetic disorder of mitochondrial metabolism. The clinical manifestations range from severe neonatal lactic acidosis to chronic neurodegeneration. Optic neuropathy is an uncommon clinical sequela and the imaging findings of optic neuropathy in these patients have not previously been described. We present a patient with PDH deficiency with bilateral decreased vision in whom MRI demonstrated bilateral optic neuropathy and chiasmopathy. (orig.)

  6. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  7. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  8. On in-vivo skin topography metrology and replication techniques

    International Nuclear Information System (INIS)

    Rosen, B-G; Blunt, L; Thomas, T R

    2005-01-01

    Human skin metrology is an area of growing interest for many disciplines both in research and for commercial purposes. Changes in the skin topography are an early stage diagnosis tool not only for diseases but also give indication of the response to medical and cosmetic treatment. This paper focuses on the evaluation of in vivo and in vitro methodologies for accurate measurements of skin and outlines the quantitative characterisation of the skin topography. The study shows the applicability of in-vivo skin topography characterisation and also the advantages and limitations compared to conventional replication techniques. Finally, aspects of stripe projection methodology and 3D characterisation are discussed as a background to the proposed methodology in this paper

  9. Global snowline and mountain topography: a contrasted view

    Science.gov (United States)

    Champagnac, Jean-Daniel; Herman, Frédéric; Valla, Pierre

    2013-04-01

    The examination of the relationship between Earth's topography and present and past climate (i.e., long-term elevation of glaciers Equilibrium Line Altitude) reveals that the elevation of mountain ranges may be limited or controlled by glaciations (e.g. Porter, 1989). This is of prime importance, because glacial condition would lead to a limit the mountain development, hence the accumulation of gravitational energy and prevent the development of further glacial conditions as well as setting the erosion in (peri)glacial environments. In this study, we examine the relationships between topography and the global Equilibrium Line Altitude of alpine glaciers around the world (~ long term snowline, i.e. the altitude where the ice mass balance is null). This analysis reinforce a global study previously published (Champagnac et al., 2012), and provide a much finer view of the climate-topography-tectonics relationships. Specifically, two main observations can be drawn: 1) The distance between the (averaged and maximum) topography, and the ELA decreases pole ward the poles, and even become reversed (mean elevation above to ELA) at high latitude. Correlatively, the elevation of very large portion of land at mid-latitude cannot be related to glaciations, simply because it was never glaciated (large distance between topography and long-term mean ELA). The maximum distance between the ELA and the topography is greater close to the equator and decreases poleward. In absence of glacial and periglacial erosion, this trend cannot have its origin in glacial and periglacial processes. Moreover, the ELA elevation shows a significant (1000~1500m) depression in the intertropical zone. This depression of the ELA is not reflected at all in the topography 2) The distribution of relief on Earth, if normalized by the mean elevation of mountain ranges (as a proxy for available space to create relief, see Champagnac et al., 2012 for details) shows a latitudinal band of greater relief between

  10. (HEL MRI) 3D Meta Optics for High Energy Lasers

    Science.gov (United States)

    2016-09-13

    optical communication link using orbital angular momentum multiplexing ." Optics express 24, no. 9 (2016): 9794-9805. 3. Li, Yuan, Wenzhe Li, J. Miller, and...Magnusson, R.; Binun, P.; McCormick, K., "Wavelength Selection and Polarization Multiplexing of Blue Laser Diodes," in Photonics Technology Letters, IEEE...spatial multiplexing can take advantage of a non-Gaussian beam profile. If the components are to be used as out-couplers in bulk lasers , the optics

  11. Pituitary apoplexy with optic tract oedema and haemorrhage in a patient with idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Lenthall, R.; Jaspan, T.

    2001-01-01

    Bilateral optic tract oedema, left optic tract haemorrhage and subarachnoid haemorrhage occurred in a 70-year-old man with pituitary apoplexy associated with idiopathic thrombocytopenic purpura. Left optic tract haemorrhage was confirmed on MRI. (orig.)

  12. The T?lz Temporal Topography Study: Mapping the visual field across the life span. Part II: Cognitive factors shaping visual field maps

    OpenAIRE

    Poggel, Dorothe A.; Treutwein, Bernhard; Calmanti, Claudia; Strasburger, Hans

    2012-01-01

    Part I described the topography of visual performance over the life span. Performance decline was explained only partly by deterioration of the optical apparatus. Part II therefore examines the influence of higher visual and cognitive functions. Visual field maps for 95 healthy observers of static perimetry, double-pulse resolution (DPR), reaction times, and contrast thresholds, were correlated with measures of visual attention (alertness, divided attention, spatial cueing), visual search, an...

  13. Mapping Bedrock Topography using Electromagnetic Profiling ...

    African Journals Online (AJOL)

    Mapping Bedrock Topography using Electromagnetic Profiling. ... will be constructed The area under study is within the Abakaliki Shales Geologic Formation. ... micaceous sandstone; micaceous siltstone, sandy shales and shelly limestone.

  14. Investigating Flow Features Near Abrupt Topography in the Mariana Basin

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Investigating Flow Features Near Abrupt Topography in...waves generated by flow over topography and mesoscale eddies generated by flow past islands. Having identified the prime locations in the region for such

  15. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  16. HLA typing in acute optic neuritis

    DEFF Research Database (Denmark)

    Frederiksen, J L; Madsen, H O; Ryder, L P

    1997-01-01

    OBJECTIVE: To study the association of brain magnetic resonance imaging (MRI) findings and HLA findings to clarify the relationship between monosymptomatic optic neuritis (ON) and ON as part of clinically definite multiple sclerosis (CDMS). DESIGN: Population-based cohort of patients with ON refe......OBJECTIVE: To study the association of brain magnetic resonance imaging (MRI) findings and HLA findings to clarify the relationship between monosymptomatic optic neuritis (ON) and ON as part of clinically definite multiple sclerosis (CDMS). DESIGN: Population-based cohort of patients......: The frequency of HLA-DR15 was significantly increased in patients with ON + CDMS (52%) and ON (47%) compared with control subjects (31%). The frequency of HLA-DR17 was almost equal in the ON + CDMS (18%), ON (23%), and control (23%) groups. The frequencies of HLA-DQA-1B (55% in ON + CDMS, 58% in ON) and HLA...

  17. Studies on improvement of diagnosis of neurosurgical lesions by magnetic resonance imaging (MRI), 2

    International Nuclear Information System (INIS)

    Shimizu, Kotoyuki

    1989-01-01

    Findings of magnetic resonance (MRI) imaging in 46 patients with sellar or parasellar mass were reviewed and compared with those of concurrently available X-ray CT. Intrasellar contents, the hypothalamic pituitary region, adjacent brain stem, optic nerves, and the surrounding cerebrospinal fluid were clearly depicted on T1-weighted images. The cavernous sinus and blood vessels, including the Willis circle, were visualized on T2-weighted images. In detecting pituitary macroadenoma, MRI seemed to be the most userful modality, because it was superior to CT in identifying abnormal changes of the infundibulum, diaphragma sellae, cavernous sinus and optic chiasm. Macroadenoma of the pituitary gland was usually isointense to the normal cerebral cortex on T1- and T2-weighted images. T1- and T2-weighted relaxation times for pituitary adenoma were slightly prolonged. The normal pituitary gland was distinguishable from adenomatous tissues. For microadenoma, MRI failed to show lesions or erosion of the sellar floor. Craniopharyngioma, meningioma of the tuberculum sellae, hypothalamic tumor, such as glioma and germinoma, and the other parasellar masses were clearly visualized on MRI. MRI was superior to CT in detecting tumor and its involvement, but inferior in detecting presence of calcification. T1-weighted imaging was useful in identifing the presence of intratumoral hemorrhage. Cysts of craniopharyngioma had various appearances on T1-weighted images. High signal cyst intensity corresponded to a high cholesterol content or the presence of methemoglobin. MRI depicted empty sella. The intrasellar content had the same appearance as that of the cerebrospinal fluid space, and the flattened pituitary gland and pituitary stalk were detected on T1-weighted images. (N.K.)

  18. Biological applications of near-field scanning optical microscopy

    Science.gov (United States)

    Moers, Marco H. P.; Ruiter, A. G. T.; Jalocha, Alain; van Hulst, Niko F.; Kalle, W. H. J.; Wiegant, J. C. A. G.; Raap, A. K.

    1995-09-01

    Near-field Scanning Optical Microscopy (NSOM) is a true optical microscopic technique allowing fluorescence, absorption, reflection and polarization contrast with the additional advantage of nanometer lateral resolution, unlimited by diffraction and operation at ambient conditions. NSOM based on metal coated adiabatically tapered fibers, combined with shear force feedback and operated in illumination mode, has proven to be the most powerful NSOM arrangement, because of its true localization of the optical interaction, its various optical contrast possibilities and its sensitivity down to the single molecular level. In this paper applications of `aperture' NSOM to Fluorescence In Situ Hybridization of human metaphase chromosomes are presented, where the localized fluorescence allows to identify specific DNA sequences. All images are accompanied by the simultaneously acquired force image, enabling direct comparison of the optical contrast with the sample topography on nanometer scale, far beyond the diffraction limit. Thus the unique combination of high resolution, specific optical contrast and ambient operation offers many new direction possibilities in biological studies.

  19. Large-surface-area diamond (111) crystal plates for applications in high-heat-load wavefront-preserving X-ray crystal optics.

    Science.gov (United States)

    Stoupin, Stanislav; Antipov, Sergey; Butler, James E; Kolyadin, Alexander V; Katrusha, Andrey

    2016-09-01

    Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. The variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.

  20. Feature-based characterisation of signature topography in laser powder bed fusion of metals

    Science.gov (United States)

    Senin, Nicola; Thompson, Adam; Leach, Richard

    2018-04-01

    The use of state-of-the-art areal topography measurement instrumentation allows for a high level of detail in the acquisition of topographic information at micrometric scales. The 3D geometric models of surface topography obtained from measured data create new opportunities for the investigation of manufacturing processes through characterisation of the surfaces of manufactured parts. Conventional methods for quantitative assessment of topography usually only involve the computation of texture parameters, summary indicators of topography-related characteristics that are computed over the investigated area. However, further useful information may be obtained through characterisation of signature topographic formations, as more direct indicators of manufacturing process behaviour and performance. In this work, laser powder bed fusion of metals is considered. An original algorithmic method is proposed to isolate relevant topographic formations and to quantify their dimensional and geometric properties, using areal topography data acquired by state-of-the-art areal topography measurement instrumentation.

  1. MRI findings of intracranial cavernous malformations

    International Nuclear Information System (INIS)

    Han, Byoung Hee; Kim, Dong Ik; Cho, Yong Kuk

    1995-01-01

    To analyze the variable MRI features and clinical significance of intracranial cavernous malformations. Forty patients(mean age 35.4) with cavernous malformation were evaluated by MRI. Eleven patients were surgically confirmed. Cavernous malformations were divided into four categories on the basis of the MR imaging characteristics, especially on T2-weighted image. Type I lesion was defined as an extralesional subacute hemorrhage outside the low signal rim, type II as an intralesional hemorrhage surrounded by low signal rim, type III lesion as an intralesional thrombosis with variegated central core surrounded by low signal rim, and type IV lesion as a focal old hemorrhagic core with small low signal intensity. Type IV was further divided into IVa and IVb, whether the lesion has small iso-or hypersignal central core (IVa) or not (IVb). Follow-up MRI was evaluated in 12 patients who were managed conservatively. Follow-up intervals ranged from 2 weeks to 29 months (mean 6 months). Total 80 lesions were detected in 40 patients. Multiple lesions were noted in 10 patients. The topography of the cavernous malformations was supratentorial in 75% and infratentorial in 23%. There were 10 lesions in type I, 15 in type II, 21 in type III, 14 in type IVa, and 20 in type IVb. Type I lesions mainly showed mass effect and edema. Type III lesions showed minimal contrast enhancements in 7 lesions on delayed images. Type II lesions showed the characteristics of both type I and type III lesions. On follow up images, decrease in size in 5, change of type in 7, rebleeding in 2 and no change in 12 lesions were demonstrated. Hemorrhage, edema and mass effect were combined in the cases of rebleeding. On follow-up study, the estimated risk of bleeding was 32.3%/person-year and 13.7%/lesion-year. Cavernous malformations show as variable appearance, on MR imaging suggesting variable stages of evolution. The MR morphologic classification and evaluation of secondary findings are helpful to

  2. Validating atlas-guided DOT: a comparison of diffuse optical tomography informed by atlas and subject-specific anatomies.

    Science.gov (United States)

    Cooper, Robert J; Caffini, Matteo; Dubb, Jay; Fang, Qianqian; Custo, Anna; Tsuzuki, Daisuke; Fischl, Bruce; Wells, William; Dan, Ippeita; Boas, David A

    2012-09-01

    We describe the validation of an anatomical brain atlas approach to the analysis of diffuse optical tomography (DOT). Using MRI data from 32 subjects, we compare the diffuse optical images of simulated cortical activation reconstructed using a registered atlas with those obtained using a subject's true anatomy. The error in localization of the simulated cortical activations when using a registered atlas is due to a combination of imperfect registration, anatomical differences between atlas and subject anatomies and the localization error associated with diffuse optical image reconstruction. When using a subject-specific MRI, any localization error is due to diffuse optical image reconstruction only. In this study we determine that using a registered anatomical brain atlas results in an average localization error of approximately 18 mm in Euclidean space. The corresponding error when the subject's own MRI is employed is 9.1 mm. In general, the cost of using atlas-guided DOT in place of subject-specific MRI-guided DOT is a doubling of the localization error. Our results show that despite this increase in error, reasonable anatomical localization is achievable even in cases where the subject-specific anatomy is unavailable. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Measurement of Angle Kappa Using Ultrasound Biomicroscopy and Corneal Topography.

    Science.gov (United States)

    Yeo, Joon Hyung; Moon, Nam Ju; Lee, Jeong Kyu

    2017-06-01

    To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbscan II. The mean patient age was 36.4 ± 13.8 years. The average angle kappa measured by Orbscan II was 3.98° ± 1.12°, while the average angle kappa calculated with UBM and corneal topography was 3.19° ± 1.15°. The difference in angle kappa measured by the two methods was statistically significant (p topography to calculate the angle kappa. This method is convenient to use and allows for measurement of the angle kappa without an expensive device. © 2017 The Korean Ophthalmological Society

  4. Influence of surface topography on elastically backscattered electrons

    International Nuclear Information System (INIS)

    Ding, X; Da, B; Gong, J B; Ding, Z J; Mao, S F

    2014-01-01

    A Monte Carlo simulation, taking into account of the detailed surface roughness of a realistic solid sample, has been performed to study the surface topography influence on elastic peak intensity. To describe quantitatively the surface topography effect, here we introduce surface roughness parameter (SRP) according to the ratio of elastic peak intensities between a rough surface and an ideal planar surface. Simulation results for Al sample have shown that SRP varies with surface roughness particularly at large incidence/emission angles

  5. Evaluation of dysthyroid optic neuropathy using T2-relaxation time of extraocular muscle as parameter

    International Nuclear Information System (INIS)

    Yu, Fumihiko; Maeda, Toshine; Inoue, Toyoko; Inoue, Yoichi

    2001-01-01

    The T2 value of magnetic resonance imaging (MRI) is useful in evaluating the activity of dysthyroid ophthlamopathy. We applied this method in evaluating dysthyroid optic neuropathy in 15 affected eyes of 15 patients. Another group of 40 eyes of 20 patients of dysthyroid opthalmopathy without hypertrophy of extraocular muscles served as control. The T2 value in dysthyroid optic neuropathy significantly decreased following treatment with corticosteroid but the value was still higher than that in control eyes. The findings show that the T2 value of MRI is useful in evaluating the therapeutic effect of dysthyroid optic neuropathy. (author)

  6. Evaluation of dysthyroid optic neuropathy using T2-relaxation time of extraocular muscle as parameter

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Fumihiko; Maeda, Toshine; Inoue, Toyoko; Inoue, Yoichi [Olympia Eye Hospital, Tokyo (Japan)

    2001-11-01

    The T2 value of magnetic resonance imaging (MRI) is useful in evaluating the activity of dysthyroid ophthlamopathy. We applied this method in evaluating dysthyroid optic neuropathy in 15 affected eyes of 15 patients. Another group of 40 eyes of 20 patients of dysthyroid opthalmopathy without hypertrophy of extraocular muscles served as control. The T2 value in dysthyroid optic neuropathy significantly decreased following treatment with corticosteroid but the value was still higher than that in control eyes. The findings show that the T2 value of MRI is useful in evaluating the therapeutic effect of dysthyroid optic neuropathy. (author)

  7. Inner core boundary topography explored with reflected and diffracted P waves

    Science.gov (United States)

    deSilva, Susini; Cormier, Vernon F.; Zheng, Yingcai

    2018-03-01

    The existence of topography of the inner core boundary (ICB) can affect the amplitude, phase, and coda of body waves incident on the inner core. By applying pseudospectral and boundary element methods to synthesize compressional waves interacting with the ICB, these effects are predicted and compared with waveform observations in pre-critical, critical, post-critical, and diffraction ranges of the PKiKP wave reflected from the ICB. These data sample overlapping regions of the inner core beneath the circum-Pacific belt and the Eurasian, North American, and Australian continents, but exclude large areas beneath the Pacific and Indian Oceans and the poles. In the pre-critical range, PKiKP waveforms require an upper bound of 2 km at 1-20 km wavelength for any ICB topography. Higher topography sharply reduces PKiKP amplitude and produces time-extended coda not observed in PKiKP waveforms. The existence of topography of this scale smooths over minima and zeros in the pre-critical ICB reflection coefficient predicted from standard earth models. In the range surrounding critical incidence (108-130 °), this upper bound of topography does not strongly affect the amplitude and waveform behavior of PKIKP + PKiKP at 1.5 Hz, which is relatively insensitive to 10-20 km wavelength topography height approaching 5 km. These data, however, have a strong overlap in the regions of the ICB sampled by pre-critical PKiKP that require a 2 km upper bound to topography height. In the diffracted range (>152°), topography as high as 5 km attenuates the peak amplitudes of PKIKP and PKPCdiff by similar amounts, leaving the PKPCdiff/PKIKP amplitude ratio unchanged from that predicted by a smooth ICB. The observed decay of PKPCdiff into the inner core shadow and the PKIKP-PKPCdiff differential travel time are consistent with a flattening of the outer core P velocity gradient near the ICB and iron enrichment at the bottom of the outer core.

  8. The Tölz Temporal Topography Study: mapping the visual field across the life span. Part I: the topography of light detection and temporal-information processing.

    Science.gov (United States)

    Poggel, Dorothe A; Treutwein, Bernhard; Calmanti, Claudia; Strasburger, Hans

    2012-08-01

    Temporal performance parameters vary across the visual field. Their topographical distributions relative to each other and relative to basic visual performance measures and their relative change over the life span are unknown. Our goal was to characterize the topography and age-related change of temporal performance. We acquired visual field maps in 95 healthy participants (age: 10-90 years): perimetric thresholds, double-pulse resolution (DPR), reaction times (RTs), and letter contrast thresholds. DPR and perimetric thresholds increased with eccentricity and age; the periphery showed a more pronounced age-related increase than the center. RT increased only slightly and uniformly with eccentricity. It remained almost constant up to the age of 60, a marked change occurring only above 80. Overall, age was a poor predictor of functionality. Performance decline could be explained only in part by the aging of the retina and optic media. In Part II, we therefore examine higher visual and cognitive functions.

  9. Ultrasound imaging measurement of submerged topography in the muddy water physical model

    International Nuclear Information System (INIS)

    Xiao, Xiongwu; Guo, Bingxuan; Li, Deren; Zhang, Peng; Zang, Yu-fu; Zou, Xianjian; Liu, Jian-chen

    2015-01-01

    The real-time, accurate measurement of submerged topography is vital for the analysis of riverbed erosion and deposition. This paper describes a novel method of measuring submerged topography in the B-scan image obtained using an ultrasound imaging device. Results show the distribution of gray values in the image has a process of mutation. This mutation process can be used to adaptively track the topographic lines between riverbed and water, based on the continuity of topography in the horizontal direction. The extracted topographic lines, of one pixel width, are processed by a wavelet filtering method. Compared with the actual topography, the measurement accuracy is within 1 mm. It is suitable for the real-time measurement and analysis of all current model topographies with the advantage of good self-adaptation. In particular, it is visible and intuitive for muddy water in the movable-bed model experiment. (paper)

  10. Nano-topography Enhances Communication in Neural Cells Networks

    KAUST Repository

    Onesto, V.

    2017-08-23

    Neural cells are the smallest building blocks of the central and peripheral nervous systems. Information in neural networks and cell-substrate interactions have been heretofore studied separately. Understanding whether surface nano-topography can direct nerve cells assembly into computational efficient networks may provide new tools and criteria for tissue engineering and regenerative medicine. In this work, we used information theory approaches and functional multi calcium imaging (fMCI) techniques to examine how information flows in neural networks cultured on surfaces with controlled topography. We found that substrate roughness Sa affects networks topology. In the low nano-meter range, S-a = 0-30 nm, information increases with Sa. Moreover, we found that energy density of a network of cells correlates to the topology of that network. This reinforces the view that information, energy and surface nano-topography are tightly inter-connected and should not be neglected when studying cell-cell interaction in neural tissue repair and regeneration.

  11. Diffusive boundary layers over varying topography

    KAUST Repository

    Dell, R. W.

    2015-03-25

    Diffusive bottom boundary layers can produce upslope flows in a stratified fluid. Accumulating observations suggest that these boundary layers may drive upwelling and mixing in mid-ocean ridge flank canyons. However, most studies of diffusive bottom boundary layers to date have concentrated on constant bottom slopes. We present a study of how diffusive boundary layers interact with various idealized topography, such as changes in bottom slope, slopes with corrugations and isolated sills. We use linear theory and numerical simulations in the regional ocean modeling system (ROMS) model to show changes in bottom slope can cause convergences and divergences within the boundary layer, in turn causing fluid exchanges that reach far into the overlying fluid and alter stratification far from the bottom. We also identify several different regimes of boundary-layer behaviour for topography with oceanographically relevant size and shape, including reversing flows and overflows, and we develop a simple theory that predicts the regime boundaries, including what topographies will generate overflows. As observations also suggest there may be overflows in deep canyons where the flow passes over isolated bumps and sills, this parameter range may be particularly significant for understanding the role of boundary layers in the deep ocean.

  12. Incorpararion of Topography Effect Into Two-Dimensional DC Resistivity Modelling by Using Finite-Element Method

    International Nuclear Information System (INIS)

    Erdogan, E.

    2007-01-01

    In earth investigation done by using the direct current resistivity technique, impact of the change in the examined surface topography on determining the resistivity distrubition in the earth has been a frequently faced question. In order to get more fruitful results and make more correct interpretetions in earth surveying carried on the areas where topographical changes occur, modelling should be done by taking the change in surface topography into account and topography effect should be included into inversion. In this study impact of topography to the direct current resistivity method has been analysed. For this purpose, 2-D forward modeling algorithm has been developed by using finite element method. In this algorithm impact of topography can be incorporate into the model. Also the pseudo sections which is produced from the program can be imaged with topography. By using this algorithm response of models under different surface topography has been analysed and compared with the straight topography of same models

  13. Optically induced dynamic nuclear spin polarisation in diamond

    International Nuclear Information System (INIS)

    Scheuer, Jochen; Naydenov, Boris; Jelezko, Fedor; Schwartz, Ilai; Chen, Qiong; Plenio, Martin B; Schulze-Sünninghausen, David; Luy, Burkhard; Carl, Patrick; Höfer, Peter; Retzker, Alexander; Sumiya, Hitoshi; Isoya, Junichi

    2016-01-01

    The sensitivity of magnetic resonance imaging (MRI) depends strongly on nuclear spin polarisation and, motivated by this observation, dynamical nuclear spin polarisation has recently been applied to enhance MRI protocols (Kurhanewicz et al 2011 Neoplasia 13 81). Nuclear spins associated with the 13 C carbon isotope (nuclear spin I = 1/2) in diamond possess uniquely long spin lattice relaxation times (Reynhardt and High 2011 Prog. Nucl. Magn. Reson. Spectrosc. 38 37). If they are present in diamond nanocrystals, especially when strongly polarised, they form a promising contrast agent for MRI. Current schemes for achieving nuclear polarisation, however, require cryogenic temperatures. Here we demonstrate an efficient scheme that realises optically induced 13 C nuclear spin hyperpolarisation in diamond at room temperature and low ambient magnetic field. Optical pumping of a nitrogen-vacancy centre creates a continuously renewable electron spin polarisation which can be transferred to surrounding 13 C nuclear spins. Importantly for future applications we also realise polarisation protocols that are robust against an unknown misalignment between magnetic field and crystal axis. (paper)

  14. Design of a multimodal fibers optic system for small animal optical imaging.

    Science.gov (United States)

    Spinelli, Antonello E; Pagliazzi, Marco; Boschi, Federico

    2015-02-01

    Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Disease Activity and Conversion into Multiple Sclerosis after Optic Neuritis Is Treated with Erythropoietin

    Directory of Open Access Journals (Sweden)

    Kurt-Wolfram Sühs

    2016-09-01

    Full Text Available Changes in cerebral lesion load by magnetic resonance imaging (MRI in patients from a double-blind, placebo-controlled, phase II study on erythropoietin in clinically isolated optic neuritis (ClinicalTrials.gov, NCT00355095 were analyzed. Therefore, patients with acute optic neuritis were assigned to receive either 33,000 IU of recombinant human erythropoietin (IV daily for three days, or a placebo, as an add-on to methylprednisolone. Of 35 patients, we investigated changes in cerebral lesion load in MRIs obtained at baseline and at weeks 4, 8, and 16. In 5 of the 35 patients, we found conversion into multiple sclerosis (MS based on MRI progression only. These five patients had received the placebo. Another five patients showed MRI progression together with relapses. Three of these patients had received erythropoietin, and two the placebo. Yet, analyzing the change in absolute numbers of periventricular, juxtacortical, and infratentorial lesions including gadolinium-enhancing lesions, there were no significant differences between the groups. Although effective in terms of retinal nerve fiber layer protection, erythropoietin treatment of acute isolated optic neuritis did not influence further evolution of MRI lesions in the brain when comparing absolute numbers. However, early conversion from clinically isolated syndrome to MS assessed by MRI activity seemed to occur more frequently in the placebo-treated group.

  16. Topography and refractometry of sperm cells using spatial light interference microscopy.

    Science.gov (United States)

    Liu, Lina; Kandel, Mikhail E; Rubessa, Marcello; Schreiber, Sierra; Wheeler, Mathew B; Popescu, Gabriel

    2018-02-01

    Characterization of spermatozoon viability is a common test in treating infertility. Recently, it has been shown that label-free, phase-sensitive imaging can provide a valuable alternative for this type of assay. We employ spatial light interference microscopy (SLIM) to perform high-accuracy single-cell phase imaging and decouple the average thickness and refractive index information for the population. This procedure was enabled by quantitative-phase imaging cells on media of two different refractive indices and using a numerical tool to remove the curvature from the cell tails. This way, we achieved ensemble averaging of topography and refractometry of 100 cells in each of the two groups. The results show that the thickness profile of the cell tail goes down to 150 nm and the refractive index can reach values of 1.6 close to the head. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  17. Utility of coronal contrast-enhanced fat-suppressed FLAIR in the evaluation of optic neuropathy and atrophy.

    Science.gov (United States)

    Boegel, Kevin H; Tyan, Andrew E; Iyer, Veena R; Rykken, Jeffrey B; McKinney, Alexander M

    2017-01-01

    Evaluating chronic sequelae of optic neuritis, such as optic neuropathy with or without optic nerve atrophy, can be challenging on whole brain MRI. This study evaluated the utility of dedicated coronal contrast-enhanced fat-suppressed FLAIR (CE-FS-FLAIR) MR imaging to detect optic neuropathy and optic nerve atrophy. Over 4.5 years, a 3 mm coronal CE-FS-FLAIR sequence at 1.5T was added to the routine brain MRIs of 124 consecutive patients, 102 of whom had suspected or known demyelinating disease. Retrospective record reviews confirmed that 28 of these 102 had documented onset of optic neuritis >4 weeks prior to the brain MRI. These 28 were compared to the other 22 ("controls") of the 124 patients who lacked a history of demyelinating disease or visual symptoms. Using coronal CE-FS-FLAIR, two neuroradiologists separately graded each optic nerve (n = 50 patients, 100 total nerves) as either negative, equivocal, or positive for optic neuropathy or atrophy. The scoring was later repeated. The mean time from acute optic neuritis onset to MRI was 4.1 ± 4.6 years (range 34 days-17.4 years). Per individual nerve grading, the range of sensitivity, specificity, and accuracy of coronal CE-FS-FLAIR in detecting optic neuropathy was 71.4-77.1%, 93.8-95.4%, and 85.5-89.0%, respectively, with strong interobserver (k = 0.667 - 0.678, p optic atrophy, interobserver agreement was moderate (k = 0.437 - 0.484, p optic neuropathy years after the onset of acute optic neuritis, but is less useful in detecting optic nerve atrophy.

  18. Venus gravity anomalies and their correlations with topography

    Science.gov (United States)

    Sjogren, W. L.; Bills, B. G.; Birkeland, P. W.; Esposito, P. B.; Konopliv, A. R.; Mottinger, N. A.; Ritke, S. J.; Phillips, R. J.

    1983-01-01

    This report provides a summary of the high-resolution gravity data obtained from the Pioneer Venus Orbiter radio tracking data. Gravity maps, covering a 70 deg latitude band through 360 deg of longitude, are displayed as line-of-sight and vertical gravity. Topography converted to gravity and Bouguer gravity maps are also shown in both systems. Topography to gravity ratios are made over several regions of the planet. There are markedly different ratios for the Aphrodite area as compared to the Beta and Atla areas.

  19. Meningeal involvement in Behcet's disease: MRI

    International Nuclear Information System (INIS)

    Guma, A.; Aguilera, C.; Pons, L.; Acebes, J.; Arruga, J.

    1998-01-01

    Behcet's disease is a multisystem disease that involves the central nervous system up to half of cases. Presentation with neurologic symptoms occurs in 5 % of cases and cerebral venous thrombosis is one of its major manifestations. A feature not previously reported is progressive meningeal thickening with involvement of both optic nerves. We report a patient with cerebral venous thrombosis, meningeal thickening and contrast enhancement on MRI. This patient had two other unusual features: positive antineutrophil cytoplasmic antibodies and later development of central diabetes insipidus. (orig.)

  20. Leveraging High Resolution Topography for Education and Outreach: Updates to OpenTopography to make EarthScope and Other Lidar Datasets more Prominent in Geoscience Education

    Science.gov (United States)

    Kleber, E.; Crosby, C. J.; Arrowsmith, R.; Robinson, S.; Haddad, D. E.

    2013-12-01

    The use of Light Detection and Ranging (lidar) derived topography has become an indispensable tool in Earth science research. The collection of high-resolution lidar topography from an airborne or terrestrial platform allows landscapes and landforms to be represented at sub-meter resolution and in three dimensions. In addition to its high value for scientific research, lidar derived topography has tremendous potential as a tool for Earth science education. Recent science education initiatives and a community call for access to research-level data make the time ripe to expose lidar data and derived data products as a teaching tool. High resolution topographic data fosters several Disciplinary Core Ideas (DCIs) of the Next Generation Science Standards (NGS, 2013), presents respective Big Ideas of the new community-driven Earth Science Literacy Initiative (ESLI, 2009), teaches to a number National Science Education Standards (NSES, 1996), and Benchmarks for Science Literacy (AAAS, 1993) for science education for undergraduate physical and environmental earth science classes. The spatial context of lidar data complements concepts like visualization, place-based learning, inquiry based teaching and active learning essential to teaching in the geosciences. As official host to EarthScope lidar datasets for tectonically active areas in the western United States, the NSF-funded OpenTopography facility provides user-friendly access to a wealth of data that is easily incorporated into Earth science educational materials. OpenTopography (www.opentopography.org), in collaboration with EarthScope, has developed education and outreach activities to foster teacher, student and researcher utilization of lidar data. These educational resources use lidar data coupled with free tools such as Google Earth to provide a means for students and the interested public to visualize and explore Earth's surface in an interactive manner not possible with most other remotely sensed imagery. The

  1. Optic radiation damage in multiple sclerosis is associated with visual dysfunction and retinal thinning - an ultrahigh-field MR pilot study

    International Nuclear Information System (INIS)

    Sinnecker, Tim; Oberwahrenbrock, Timm; Zimmermann, Hanna; Ramien, Caren; Brandt, Alexander U.; Metz, Imke; Brueck, Wolfgang; Pfueller, Caspar F.; Doerr, Jan; Harms, Lutz; Ruprecht, Klemens; Hahn, Katrin; Niendorf, Thoralf; Paul, Friedemann; Wuerfel, Jens

    2015-01-01

    To investigate posterior visual pathway damage in multiple sclerosis using ultrahigh-field magnetic resonance imaging (MRI) at 7 Tesla (7 T), and to determine its correlation with visual disability and retinal fibre layer (RNFL) damage detectable by optic coherence tomography (OCT). We studied 7 T MRI, OCT, functional acuity contrast testing (FACT), and visually evoked potentials (VEP, n = 16) in 30 patients (including 26 relapsing-remitting MS and four clinically isolated syndrome patients) and 12 healthy controls to quantify RNFL thickness, optic radiation lesion volume, and optic radiation thickness. Optic radiation lesion volume was associated with thinning of the optic radiation (p < 0.001), delayed VEP (p = 0.031), and visual disability indicated by FACT (p = 0.020). Furthermore, we observed an inverse correlation between optic radiation lesion volume and RNFL thickness (p < 0.001), including patients without previous optic neuritis (p < 0.001). Anterior visual pathway damage, but also (subclinical) optic radiation integrity loss detectable by 7 T MRI are common findings in MS that are mutually affected. Given the association between optic radiation damage, visual impairment, and increased VEP latency in this exploratory study of a limited sample size, clinicians should be aware of acute lesions within the optic radiation in patients with (bilateral) visual disturbances. (orig.)

  2. Optic radiation damage in multiple sclerosis is associated with visual dysfunction and retinal thinning - an ultrahigh-field MR pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Sinnecker, Tim [Charite - Universitaetsmedizin Berlin, NeuroCure Clinical Research Center, Berlin (Germany); Asklepios Fachklinikum Teupitz, Department of Neurology, Teupitz (Germany); Oberwahrenbrock, Timm; Zimmermann, Hanna; Ramien, Caren; Brandt, Alexander U. [Charite - Universitaetsmedizin Berlin, NeuroCure Clinical Research Center, Berlin (Germany); Metz, Imke; Brueck, Wolfgang [University Medicine Goettingen, Institute of Neuropathology, Goettingen (Germany); Pfueller, Caspar F.; Doerr, Jan [Charite - Universitaetsmedizin Berlin, NeuroCure Clinical Research Center, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Clinical and Experimental Multiple Sclerosis Research Center, Berlin (Germany); Harms, Lutz; Ruprecht, Klemens [Charite - Universitaetsmedizin Berlin, Clinical and Experimental Multiple Sclerosis Research Center, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Department of Neurology, Berlin (Germany); Hahn, Katrin [Charite - Universitaetsmedizin Berlin, Department of Neurology, Berlin (Germany); Niendorf, Thoralf [Max Delbrueck Center for Molecular Medicine, Berlin Ultrahigh Field Facility (B.U.F.F), Berlin (Germany); Charite - Universitaetsmedizin Berlin and Max Delbrueck Center for Molecular Medicine, Experimental and Clinical Research Center, Berlin (Germany); Paul, Friedemann [Charite - Universitaetsmedizin Berlin, NeuroCure Clinical Research Center, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Clinical and Experimental Multiple Sclerosis Research Center, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Department of Neurology, Berlin (Germany); Charite - Universitaetsmedizin Berlin and Max Delbrueck Center for Molecular Medicine, Experimental and Clinical Research Center, Berlin (Germany); Wuerfel, Jens [Charite - Universitaetsmedizin Berlin, NeuroCure Clinical Research Center, Berlin (Germany); Max Delbrueck Center for Molecular Medicine, Berlin Ultrahigh Field Facility (B.U.F.F), Berlin (Germany); University Medicine Goettingen, Institute of Neuroradiology, Goettingen (Germany)

    2015-01-15

    To investigate posterior visual pathway damage in multiple sclerosis using ultrahigh-field magnetic resonance imaging (MRI) at 7 Tesla (7 T), and to determine its correlation with visual disability and retinal fibre layer (RNFL) damage detectable by optic coherence tomography (OCT). We studied 7 T MRI, OCT, functional acuity contrast testing (FACT), and visually evoked potentials (VEP, n = 16) in 30 patients (including 26 relapsing-remitting MS and four clinically isolated syndrome patients) and 12 healthy controls to quantify RNFL thickness, optic radiation lesion volume, and optic radiation thickness. Optic radiation lesion volume was associated with thinning of the optic radiation (p < 0.001), delayed VEP (p = 0.031), and visual disability indicated by FACT (p = 0.020). Furthermore, we observed an inverse correlation between optic radiation lesion volume and RNFL thickness (p < 0.001), including patients without previous optic neuritis (p < 0.001). Anterior visual pathway damage, but also (subclinical) optic radiation integrity loss detectable by 7 T MRI are common findings in MS that are mutually affected. Given the association between optic radiation damage, visual impairment, and increased VEP latency in this exploratory study of a limited sample size, clinicians should be aware of acute lesions within the optic radiation in patients with (bilateral) visual disturbances. (orig.)

  3. Relating Cenozoic North Sea sediments to topography in southern Norway:

    DEFF Research Database (Denmark)

    Anell, Ingrid Anna Margareta; Thybo, Hans; Stratford, Wanda Rose

    2010-01-01

    the Shetland platform continued throughout the Cenozoic while supply from southern Norway increased markedly around the Eocene–Oligocene, coeval with the greenhouse–icehouse transition. Mass balance calculations of sediment and eroded rock volumes suggest that while some topography along the western margin...... that Plio-Pleistocene erosion over-deepened a pre-existing topography....

  4. Mesenchymal chondrosarcoma of the orbit: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.T., E-mail: cjr.yangbentao@vip.163.com [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China); Wang, Y.Z.; Wang, X.Y.; Wang, Z.C. [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing (China)

    2012-04-15

    Aim: To describe the computed tomography (CT) and magnetic resonance imaging (MRI) features of orbital mesenchymal chondrosarcomas (MCSs). Materials and methods: Six patients with histology-confirmed MCSs of the orbit were retrospectively reviewed. All six patients underwent CT and MRI. Imaging studies were evaluated for the following: (a) tumour location, (b) configuration, size, and margin, (c) CT attenuation and MRI signal intensity, and (d) secondary manifestations. Additionally, the time-intensity curve (TIC) of dynamic contrast-enhanced (DCE) MRI were analysed in five patients. Results: Two MCSs arose in the right orbit and four in the left orbit. Five MCSs were located in the retrobulbar intraconal space and one in the extraconal space. All the lesions displayed a lobulate configuration and had a well-defined margin. The mean maximum diameter was 25.8 mm (range 15-36 mm). On unenhanced CT, the lesions appeared isodense to grey matter in six patients, with calcifications in five. Two patients showed inhomogeneous, moderate enhancement on enhanced CT. Six MCSs appeared isointense on T1-weighted imaging and heterogeneously isointense on T2-weighted imaging. The lesions showed significantly heterogeneous contrast enhancement. Five patients had DCE MRI and the TICs showed a rapidly enhancing and rapid washout pattern (type III). The following features were also detected: compression of the extra-ocular muscle (six patients, 100%); displacement of the optic nerve (five patients, 83.3%); and encasing globe (three patients, 50%). Conclusions: A well-defined, lobulate orbital mass with calcification on CT and, marked heterogeneous enhancement and type III TIC on MRI are highly suspicious of orbital MCSs.

  5. Assessing Bioinspired Topographies for their Antifouling Potential Control Using Computational Fluid Dynamics (CFD

    Directory of Open Access Journals (Sweden)

    Ling Jacky

    2018-01-01

    Full Text Available Biofouling is the accumulation of unwanted material on surfaces submerged or semi submerged over an extended period. This study investigates the antifouling performance of a new bioinspired topography design. A shark riblets inspired topography was designed with Solidworks and CFD simulations were antifouling performance. The study focuses on the fluid flow velocity, the wall shear stress and the appearance of vortices are to be noted to determine the possible locations biofouling would most probably occur. The inlet mass flow rate is 0.01 kgs-1 and a no-slip boundary condition was applied to the walls of the fluid domain. Simulations indicate that Velocity around the topography averaged at 7.213 x 10-3 ms-1. However, vortices were observed between the gaps. High wall shear stress is observed at the peak of each topography. In contrast, wall shear stress is significantly low at the bed of the topography. This suggests the potential location for the accumulation of biofouling. Results show that bioinspired antifouling topography can be improved by reducing the frequency of gaps between features. Linear surfaces on the topography should also be minimized. This increases the avenues of flow for the fluid, thus potentially increasing shear stresses with surrounding fluid leading to better antifouling performance.

  6. Cokriging surface elevation and seismic refraction data for bedrock topography

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Doll, W.E.; Davis, R.K.; Hopkins, R.A.

    1992-01-01

    Analysis of seismic refraction data collected at a proposed site of the Advanced Neutron Source (ANS) Facility showed a strong correlation between surface and bedrock topography. By combining seismically determined bedrock elevation data with surface elevation data using cokriging, we were able to significantly improve our map of bedrock topography without collecting additional seismic data

  7. Influence of topography on landscape radiation temperature distribution

    International Nuclear Information System (INIS)

    Florinsky, I.V.; Kulagina, T.B.; Meshalkina, J.L.

    1994-01-01

    The evaluation of the influence of topography on landscape radiation temperature distribution is carried out by statistical processing of digital models of elevation, gradient, aspect, horizontal, vertical and mean land surface curvatures and the infrared thermal scene generated by the Thermovision 880 system. Significant linear correlation coefficients between the landscape radiation temperature and elevation, slope, aspect, vertical and mean landsurface curvatures are determined, being —0-57, 0 38, 0-26, 015, 013, respectively. The equation of the topography influence on the distribution of the landscape radiation temperature is defined. (author)

  8. The Tölz Temporal Topography Study: mapping the visual field across the life span. Part II: cognitive factors shaping visual field maps.

    Science.gov (United States)

    Poggel, Dorothe A; Treutwein, Bernhard; Calmanti, Claudia; Strasburger, Hans

    2012-08-01

    Part I described the topography of visual performance over the life span. Performance decline was explained only partly by deterioration of the optical apparatus. Part II therefore examines the influence of higher visual and cognitive functions. Visual field maps for 95 healthy observers of static perimetry, double-pulse resolution (DPR), reaction times, and contrast thresholds, were correlated with measures of visual attention (alertness, divided attention, spatial cueing), visual search, and the size of the attention focus. Correlations with the attentional variables were substantial, particularly for variables of temporal processing. DPR thresholds depended on the size of the attention focus. The extraction of cognitive variables from the correlations between topographical variables and participant age substantially reduced those correlations. There is a systematic top-down influence on the aging of visual functions, particularly of temporal variables, that largely explains performance decline and the change of the topography over the life span.

  9. Allometric scaling of infraorbital surface topography in Homo.

    Science.gov (United States)

    Maddux, Scott D; Franciscus, Robert G

    2009-02-01

    Infraorbital morphology is often included in phylogenetic and functional analyses of Homo. The inclusion of distinct infraorbital configurations, such as the "canine fossa" in Homo sapiens or the "inflated" maxilla in Neandertals, is generally based on either descriptive or qualitative assessments of this morphology, or simple linear chord and subtense measurements. However, the complex curvilinear surface of the infraorbital region has proven difficult to quantify through these traditional methods. In this study, we assess infraorbital shape and its potential allometric scaling in fossil Homo (n=18) and recent humans (n=110) with a geometric morphometric method well-suited for quantifying complex surface topographies. Our results indicate that important aspects of infraorbital shape are correlated with overall infraorbital size across Homo. Specifically, individuals with larger infraorbital areas tend to exhibit relatively flatter infraorbital surface topographies, taller and narrower infraorbital areas, sloped inferior orbital rims, anteroinferiorly oriented maxillary body facies, posteroinferiorly oriented maxillary processes of the zygomatic, and non-everted lateral nasal margins. In contrast, individuals with smaller infraorbital regions generally exhibit relatively depressed surface topographies, shorter and wider infraorbital areas, projecting inferior orbital rims, posteroinferiorly oriented maxillary body facies, anteroinferiorly oriented maxillary processes, and everted lateral nasal margins. These contrasts form a continuum and only appear dichotomized at the ends of the infraorbital size spectrum. In light of these results, we question the utility of incorporating traditionally polarized infraorbital morphologies in phylogenetic and functional analyses without due consideration of continuous infraorbital and facial size variation in Homo. We conclude that the essentially flat infraorbital surface topography of Neandertals is not unique and can be

  10. ATM Coastal Topography-Florida 2001: Eastern Panhandle

    Science.gov (United States)

    Yates, Xan; Nayegandhi, Amar; Brock, John C.; Sallenger, A.H.; Bonisteel, Jamie M.; Klipp, Emily S.; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of Lidar-derived first surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of the eastern Florida panhandle coastline, acquired October 2, 2001. The datasets are made available for use as a management tool to research scientists and natural resource managers. An innovative scanning Lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning Lidar system that measures high-resolution topography of the land surface and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser-ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of Lidar data in an interactive or batch mode. Modules for presurvey flight line definition, flight path plotting, Lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant return within each waveform. ALPS is routinely used to create

  11. ATM Coastal Topography-Florida 2001: Western Panhandle

    Science.gov (United States)

    Yates, Xan; Nayegandhi, Amar; Brock, John C.; Sallenger, A.H.; Bonisteel, Jamie M.; Klipp, Emily S.; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of Lidar-derived first surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of the western Florida panhandle coastline, acquired October 2-4 and 7-10, 2001. The datasets are made available for use as a management tool to research scientists and natural resource managers. An innovative scanning Lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning Lidar system that measures high-resolution topography of the land surface and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser-ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of Lidar data in an interactive or batch mode. Modules for presurvey flight line definition, flight path plotting, Lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant return within each waveform. ALPS is routinely used

  12. Molecular MRI based on hyper-polarized xenon

    International Nuclear Information System (INIS)

    Tassali, Nawal

    2012-01-01

    Magnetic Resonance Imaging (MRI) has a high importance in medicine as it enables the observation of the organs inside the body without the use of radiative or invasive techniques. However it is known to suffer from poor sensitivity. To circumvent this limitation, a key solution resides in the use of hyper-polarized species. Among the entities with which we can drastically increase nuclear polarization, xenon has very specific properties through its interactions with its close environment that lead to a wide chemical shift bandwidth. The goal is thus to use it as a tracer. This PhD thesis focuses on the concept of 129 Xe MRI-based sensors for the detection of biological events. In this approach, hyper-polarized xenon is vectorized to biological targets via functionalized host systems, and then localized thanks to fast dedicated MRI sequences. The conception and set-up of a spin-exchange optical pumping device is first described. Then studies about the interaction of the hyper-polarized noble gas with new cryptophanes susceptible to constitute powerful host molecules are detailed. Also the implementation of recent MRI sequences optimized for the transient character of the hyper-polarization and taking profit of the xenon in-out exchange is described. Applications of this approach for the detection of metallic ions and cellular receptors are studied. Finally, our first in vivo results on a small animal model are presented. (author) [fr

  13. Comparison between optical techniques and confocal microscopy for defect detection on thin wires

    International Nuclear Information System (INIS)

    Siegmann, Philip; Sanchez-Brea, Luis Miguel; Martinez-Anton, Juan Carlos; Bernabeu, Eusebio

    2004-01-01

    Conventional microscopy techniques, such as atomic force microscopy (AFM), scanning electron microscopy (SEM), and confocal microscopy (CM) are not suitable for on-line surface inspection of fine metallic wires. In the recent years, some optical techniques have been developed to be used for those tasks. However, they need a rigorous validation. In this work, we have used confocal microscopy to obtain the topography z(x,y) of wires with longitudinal defects, such as dielines. The topography has been used to predict the light scattered by the wire. These simulations have been compared with experimental results, showing a good agreement

  14. A framework for integration of scientific applications into the OpenTopography workflow

    Science.gov (United States)

    Nandigam, V.; Crosby, C.; Baru, C.

    2012-12-01

    The NSF-funded OpenTopography facility provides online access to Earth science-oriented high-resolution LIDAR topography data, online processing tools, and derivative products. The underlying cyberinfrastructure employs a multi-tier service oriented architecture that is comprised of an infrastructure tier, a processing services tier, and an application tier. The infrastructure tier consists of storage, compute resources as well as supporting databases. The services tier consists of the set of processing routines each deployed as a Web service. The applications tier provides client interfaces to the system. (e.g. Portal). We propose a "pluggable" infrastructure design that will allow new scientific algorithms and processing routines developed and maintained by the community to be integrated into the OpenTopography system so that the wider earth science community can benefit from its availability. All core components in OpenTopography are available as Web services using a customized open-source Opal toolkit. The Opal toolkit provides mechanisms to manage and track job submissions, with the help of a back-end database. It allows monitoring of job and system status by providing charting tools. All core components in OpenTopography have been developed, maintained and wrapped as Web services using Opal by OpenTopography developers. However, as the scientific community develops new processing and analysis approaches this integration approach is not scalable efficiently. Most of the new scientific applications will have their own active development teams performing regular updates, maintenance and other improvements. It would be optimal to have the application co-located where its developers can continue to actively work on it while still making it accessible within the OpenTopography workflow for processing capabilities. We will utilize a software framework for remote integration of these scientific applications into the OpenTopography system. This will be accomplished by

  15. In-room ultrasound fusion combined with fully compatible 3D-printed holding arm – rethinking interventional MRI

    Directory of Open Access Journals (Sweden)

    Friebe M

    2018-03-01

    Full Text Available Michael Friebe,1 Juan Sanchez,1 Sathish Balakrishnan,1 Alfredo Illanes,1 Yeshaswini Nagaraj,2 Robert Odenbach,1 Marwah Matooq,1 Gabriele Krombach,3 Michael Vogele,4 Axel Boese1 1Chair of Intelligent Catheter, Otto-von-Guericke-University, Magdeburg, Germany; 2University of Groningen, University Medical Center Groningen, Center for Medical Imaging North East Netherlands, Groningen, the Netherlands; 3Universitätsklinikum Giessen, Radiologische Klinik, Giessen, Germany; 4Interventional Systems GmbH, Kitzbühel, Austria Abstract: There is no real need to discuss the potential advantages – mainly the excellent soft tissue contrast, nonionizing radiation, flow, and molecular information – of magnetic resonance imaging (MRI as an intraoperative diagnosis and therapy system particularly for neurological applications and oncological therapies. Difficult patient access in conventional horizontal-field superconductive magnets, very high investment and operational expenses, and the need for special nonferromagnetic therapy tools have however prevented the widespread use of MRI as imaging and guidance tool for therapy purposes. The interventional use of MRI systems follows for the last 20+ years the strategy to use standard diagnostic systems and add more or less complicated and expensive components (eg, MRI-compatible robotic systems, specially shielded in-room monitors, dedicated tools and devices made from low-susceptibility materials, etc to overcome the difficulties in the therapy process. We are proposing to rethink that approach using an in-room portable ultrasound (US system that can be safely operated till 1 m away from the opening of a 3T imaging system. The live US images can be tracked using an optical inside–out approach adding a camera to the US probe in combination with optical reference markers to allow direct fusion with the MRI images inside the MRI suite. This leads to a comfortable US-guided intervention and excellent patient

  16. fMRI-Compatible Electromagnetic Haptic Interface.

    Science.gov (United States)

    Riener, R; Villgrattner, T; Kleiser, R; Nef, T; Kollias, S

    2005-01-01

    A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.

  17. Role of the Nucleus as a Sensor of Cell Environment Topography.

    Science.gov (United States)

    Anselme, Karine; Wakhloo, Nayana Tusamda; Rougerie, Pablo; Pieuchot, Laurent

    2018-04-01

    The proper integration of biophysical cues from the cell vicinity is crucial for cells to maintain homeostasis, cooperate with other cells within the tissues, and properly fulfill their biological function. It is therefore crucial to fully understand how cells integrate these extracellular signals for tissue engineering and regenerative medicine. Topography has emerged as a prominent component of the cellular microenvironment that has pleiotropic effects on cell behavior. This progress report focuses on the recent advances in the understanding of the topography sensing mechanism with a special emphasis on the role of the nucleus. Here, recent techniques developed for monitoring the nuclear mechanics are reviewed and the impact of various topographies and their consequences on nuclear organization, gene regulation, and stem cell fate is summarized. The role of the cell nucleus as a sensor of cell-scale topography is further discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Assessment of early-stage optic nerve invasion in retinoblastoma using high-resolution 1.5 Tesla MRI with surface coils: a multicentre, prospective accuracy study with histopathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brisse, Herve J. [Institut Curie, Department of Radiology, Paris (France); Institut CURIE, Imaging Department, Paris (France); Graaf, Pim de; Rodjan, Firazia; Jong, Marcus C. de; Castelijns, Jonas A. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Galluzzi, Paolo [Neuroimaging and Neurointerventional Unit (NINT) Azienda Ospedaliera e Universitaria Senese, Siena (Italy); Cosker, Kristel; Savignoni, Alexia [Institut Curie, Department of Biostatistics, Paris (France); Maeder, Philippe [Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne, Department of Radiology, Lausanne (Switzerland); Goericke, Sophia [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Aerts, Isabelle [Institut Curie, Department of Pediatric Oncology, Paris (France); Desjardins, Laurence [Institut Curie, Department of Ophthalmology, Paris (France); Moll, Annette C. [VU University Medical Center, Department of Ophthalmology, Amsterdam (Netherlands); Hadjistilianou, Theodora [Azienda Ospedaliera Universitaria Senese, Department of Ophthalmology, Siena (Italy); Toti, Paolo [University of Siena, Department of Medical Biotechnologies, Pathology Unit, Siena (Italy); Valk, Paul van der [VU University Medical Center, Department of Pathology, Amsterdam (Netherlands); Sastre-Garau, Xavier [Institut Curie, Department of Biopathology, Paris (France); Collaboration: European Retinoblastoma Imaging Collaboration (ERIC)

    2015-05-01

    To assess the accuracy of high-resolution (HR) magnetic resonance imaging (MRI) in diagnosing early-stage optic nerve (ON) invasion in a retinoblastoma cohort. This IRB-approved, prospective multicenter study included 95 patients (55 boys, 40 girls; mean age, 29 months). 1.5-T MRI was performed using surface coils before enucleation, including spin-echo unenhanced and contrast-enhanced (CE) T1-weighted sequences (slice thickness, 2 mm; pixel size <0.3 x 0.3 mm{sup 2}). Images were read by five neuroradiologists blinded to histopathologic findings. ROC curves were constructed with AUC assessment using a bootstrap method. Histopathology identified 41 eyes without ON invasion and 25 with prelaminar, 18 with intralaminar and 12 with postlaminar invasion. All but one were postoperatively classified as stage I by the International Retinoblastoma Staging System. The accuracy of CE-T1 sequences in identifying ON invasion was limited (AUC = 0.64; 95 % CI, 0.55 - 0.72) and not confirmed for postlaminar invasion diagnosis (AUC = 0.64; 95 % CI, 0.47 - 0.82); high specificities (range, 0.64 - 1) and negative predictive values (range, 0.81 - 0.97) were confirmed. HR-MRI with surface coils is recommended to appropriately select retinoblastoma patients eligible for primary enucleation without the risk of IRSS stage II but cannot substitute for pathology in differentiating the first degrees of ON invasion. (orig.)

  19. Nanodiamond-enhanced MRI via in situ hyperpolarization

    Science.gov (United States)

    Waddington, David E. J.; Sarracanie, Mathieu; Zhang, Huiliang; Salameh, Najat; Glenn, David R.; Rej, Ewa; Gaebel, Torsten; Boele, Thomas; Walsworth, Ronald L.; Reilly, David J.; Rosen, Matthew S.

    2017-04-01

    Nanodiamonds are of interest as nontoxic substrates for targeted drug delivery and as highly biostable fluorescent markers for cellular tracking. Beyond optical techniques, however, options for noninvasive imaging of nanodiamonds in vivo are severely limited. Here, we demonstrate that the Overhauser effect, a proton-electron polarization transfer technique, can enable high-contrast magnetic resonance imaging (MRI) of nanodiamonds in water at room temperature and ultra-low magnetic field. The technique transfers spin polarization from paramagnetic impurities at nanodiamond surfaces to 1H spins in the surrounding water solution, creating MRI contrast on-demand. We examine the conditions required for maximum enhancement as well as the ultimate sensitivity of the technique. The ability to perform continuous in situ hyperpolarization via the Overhauser mechanism, in combination with the excellent in vivo stability of nanodiamond, raises the possibility of performing noninvasive in vivo tracking of nanodiamond over indefinitely long periods of time.

  20. Applications of corneal topography and tomography: a review.

    Science.gov (United States)

    Fan, Rachel; Chan, Tommy Cy; Prakash, Gaurav; Jhanji, Vishal

    2018-03-01

    Corneal imaging is essential for diagnosing and management of a wide variety of ocular diseases. Corneal topography is used to characterize the shape of the cornea, specifically, the anterior surface of the cornea. Most corneal topographical systems are based on Placido disc that analyse rings that are reflected off the corneal surface. The posterior corneal surface cannot be characterized using Placido disc technology. Imaging of the posterior corneal surface is useful for diagnosis of corneal ectasia. Unlike corneal topographers, tomographers generate a three-dimensional recreation of the anterior segment and provide information about the corneal thickness. Scheimpflug imaging is one of the most commonly used techniques for corneal tomography. The cross-sectional images generated by a rotating Scheimpflug camera are used to locate the anterior and posterior corneal surfaces. The clinical uses of corneal topography include, diagnosis of corneal ectasia, assessment of corneal astigmatism, and refractive surgery planning. This review will discuss the applications of corneal topography and tomography in clinical practice. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  1. Role of percent tissue altered on ectasia after LASIK in eyes with suspicious topography.

    Science.gov (United States)

    Santhiago, Marcony R; Smadja, David; Wilson, Steven E; Krueger, Ronald R; Monteiro, Mario L R; Randleman, J Bradley

    2015-04-01

    To investigate the association of the percent tissue altered (PTA) with the occurrence of ectasia after LASIK in eyes with suspicious preoperative corneal topography. This retrospective comparative case-control study compared associations of reported ectasia risk factors in 129 eyes, including 57 eyes with suspicious preoperative Placido-based corneal topography that developed ectasia after LASIK (suspect ectasia group), 32 eyes with suspicious topography that remained stable for at least 3 years after LASIK (suspect control group), and 30 eyes that developed ectasia with bilateral normal topography (normal topography ectasia group). Groups were subdivided based on topographic asymmetry into high- or low-suspect groups. The PTA, preoperative central corneal thickness (CCT), residual stromal bed (RSB), and age (years) were evaluated in univariate and multivariate analyses. Average PTA values for normal topography ectasia (45), low-suspect ectasia (39), high-suspect ectasia (36), low-suspect control (32), and high-suspect control (29) were significantly different from one another in all comparisons (P topography ectasia groups, and CCT was not significantly different between any groups. Stepwise logistic regression revealed the PTA as the most significant independent variable (P topography. Less tissue alteration, or a lower PTA value, was necessary to induce ectasia in eyes with more remarkable signs of topographic abnormality, and PTA provided better discriminative capabilities than RSB for all study populations. Copyright 2015, SLACK Incorporated.

  2. Photogrammetric portrayal of Mars topography.

    Science.gov (United States)

    Wu, S.S.C.

    1979-01-01

    Special photogrammetric techniques have been developed to portray Mars topography, using Mariner and Viking imaging and nonimaging topographic information and earth-based radar data. Topography is represented by the compilation of maps at three scales: global, intermediate, and very large scale. The global map is a synthesis of topographic information obtained from Mariner 9 and earth-based radar, compiled at a scale of 1:25,000,000 with a contour interval of 1 km; it gives a broad quantitative view of the planet. At intermediate scales, Viking Orbiter photographs of various resolutions are used to compile detailed contour maps of a broad spectrum of prominent geologic features; a contour interval as small as 20 m has been obtained from very high resolution orbital photography. Imagery from the Viking lander facsimile cameras permits construction of detailed, very large scale (1:10) topographic maps of the terrain surrounding the two landers; these maps have a contour interval of 1 cm. This paper presents several new detailed topographic maps of Mars.-Author

  3. [Radiologic follow-up after breast-conserving surgery: value of MRI examination of the breast].

    Science.gov (United States)

    Polgár, C; Forrai, G; Szabó, E; Riedl, E; Fodor, J; Fornet, B; Németh, G

    1999-11-21

    The aim of the study was to establish an objective method for evaluation the extent, topography and quantity of skin and soft tissue side effects after tele- and/or brachyradiotherapy of the conserved breast and to compare the sequales of different radiation methods. 26 patients operated on for T1-2 N0-1 breast cancer underwent the following kinds of postoperative radiotherapy: 1. 46-50 Gy whole breast teletherapy + 10-16 Gy electron boost (5 patients), 2. 46-50 Gy teletherapy + 10-15 Gy HDR brachytherapy boost (12 patients), 3. 46-50 Gy teletherapy (6 patients), 4. 36,4 Gy sole HDR brachytherapy of the tumour bed (5 patients). The postirradiation side effects were examined by MRI, mammogram, US and physical examination, as well. MRI was performed on a 0.5 T, double breast coil, with SE-T1, SE-T2 and 3D-GE sequences. The findings of MRI and mammography were compared to physically detectable side effects using the RTOG/EORTC late radiation morbidity scoring scheme. US is useful in the measurement of skin thickening and in the diagnosis of fat necrosis. Mammography and physical examination are very subjective and low specificity methods to evaluate postirradiation side effects. MRI is a suitable and more objective method to detect the real extent and quantity of skin thickening and fibrosis. The incidence of > or = G2 side effects of skin and breast parenchyma were 64.5 and 32.2%, respectively. The differences between the side effects of whole breast irradiation and sole brachytherapy of the tumour bed are also clearly demonstrated. Brachytherapy alone is feasible without compromising cosmetic results. The authors established the MRI criteria for categorization the extent and grade of skin thickening and fibrosis (focal vs diffuse, grade 1-4). Breast MRI is an objective tool for assisting to the evaluation of the side effects of postoperative radiotherapy.

  4. Preventing probe induced topography correlated artifacts in Kelvin Probe Force Microscopy

    NARCIS (Netherlands)

    Polak, L.; Wijngaarden, Rinke J.

    2016-01-01

    Kelvin Probe Force Microscopy (KPFM) on samples with rough surface topography can be hindered by topography correlated artifacts. We show that, with the proper experimental configuration and using homogeneously metal coated probes, we are able to obtain amplitude modulation (AM) KPFM results on a

  5. X-ray topography and multiple diffraction

    International Nuclear Information System (INIS)

    Chang, S.-L.

    1983-01-01

    A short summary on X-ray topography, which is based on the dynamical theory of X-ray diffraction, is made. The applications and properties related to the use of the multiple diffraction technique are analized and discussed. (L.C.) [pt

  6. Topography changes monitoring of small islands using camera drone

    Science.gov (United States)

    Bang, E.

    2017-12-01

    Drone aerial photogrammetry was conducted for monitoring topography changes of small islands in the east sea of Korea. Severe weather and sea wave is eroding the islands and sometimes cause landslide and falling rock. Due to rugged cliffs in all direction and bad accessibility, ground based survey methods are less efficient in monitoring topography changes of the whole area. Camera drones can provide digital images and movie in every corner of the islands, and drone aerial photogrammetry is powerful to get precise digital surface model (DSM) for a limited area. We have got a set of digital images to construct a textured 3D model of the project area every year since 2014. Flight height is in less than 100m from the top of those islands to get enough ground sampling distance (GSD). Most images were vertically captured with automatic flights, but we also flied drones around the islands with about 30°-45° camera angle for constructing 3D model better. Every digital image has geo-reference, but we set several ground control points (GCPs) on the islands and their coordinates were measured with RTK surveying methods to increase the absolute accuracy of the project. We constructed 3D textured model using photogrammetry tool, which generates 3D spatial information from digital images. From the polygonal model, we could get DSM with contour lines. Thematic maps such as hill shade relief map, aspect map and slope map were also processed. Those maps make us understand topography condition of the project area better. The purpose of this project is monitoring topography change of these small islands. Elevation difference map between DSMs of each year is constructed. There are two regions showing big negative difference value. By comparing constructed textured models and captured digital images around these regions, it is checked that a region have experienced real topography change. It is due to huge rock fall near the center of the east island. The size of fallen rock can be

  7. Electronic cigarettes: abuse liability, topography and subjective effects.

    Science.gov (United States)

    Evans, Sarah E; Hoffman, Allison C

    2014-05-01

    To review the available evidence evaluating the abuse liability, topography, subjective effects, craving and withdrawal suppression associated with e-cigarette use in order to identify information gaps and provide recommendations for future research. Literature searches were conducted between October 2012 and January 2014 using five electronic databases. Studies were included in this review if they were peer-reviewed scientific journal articles evaluating clinical laboratory studies, national surveys or content analyses. A total of 15 peer-reviewed articles regarding behavioural use and effects of e-cigarettes published between 2010 and 2014 were included in this review. Abuse liability studies are limited in their generalisability. Topography (consumption behaviour) studies found that, compared with traditional cigarettes, e-cigarette average puff duration was significantly longer, and e-cigarette use required stronger suction. Data on e-cigarette subjective effects (such as anxiety, restlessness, concentration, alertness and satisfaction) and withdrawal suppression are limited and inconsistent. In general, study data should be interpreted with caution, given limitations associated with comparisons of novel and usual products, as well as the possible effects associated with subjects' previous experience/inexperience with e-cigarettes. Currently, very limited information is available on abuse liability, topography and subjective effects of e-cigarettes. Opportunities to examine extended e-cigarette use in a variety of settings with experienced e-cigarette users would help to more fully assess topography as well as behavioural and subjective outcomes. In addition, assessment of 'real-world' use, including amount and timing of use and responses to use, would clarify behavioural profiles and potential adverse health effects.

  8. Stress distribution and topography of Tellus Regio, Venus

    Science.gov (United States)

    Williams, David R.; Greeley, Ronald

    1989-01-01

    The Tellus Regio area of Venus represents a subset of a narrow latitude band where Pioneer Venus Orbiter (PVO) altimetry data, line-of-sight (LOS) gravity data, and Venera 15/16 radar images have all been obtained with good resolution. Tellus Regio also has a wide variety of surface morphologic features, elevations ranging up to 2.5 km, and a relatively low LOS gravity anomaly. This area was therefore chosen in order to examine the theoretical stress distributions resulting from various models of compensation of the observed topography. These surface stress distributions are then compared with the surface morphology revealed in the Venera 15/16 radar images. Conclusions drawn from these comparisons will enable constraints to be put on various tectonic parameters relevant to Tellus Regio. The stress distribution is calculated as a function of the topography, the equipotential anomaly, and the assumed model parameters. The topography data is obtained from the PVO altimetry. The equipotential anomaly is estimated from the PVO LOS gravity data. The PVO LOS gravity represents the spacecraft accelerations due to mass anomalies within the planet. These accelerations are measured at various altitudes and angles to the local vertical and therefore do not lend themselves to a straightforward conversion. A minimum variance estimator of the LOS gravity data is calculated, taking into account the various spacecraft altitudes and LOS angles and using the measured PVO topography as an a priori constraint. This results in an estimated equivalent surface mass distribution, from which the equipotential anomaly is determined.

  9. Stress distribution and topography of Tellus Regio, Venus

    International Nuclear Information System (INIS)

    Williams, D.R.; Greeley, R.

    1989-01-01

    The Tellus Regio area of Venus represents a subset of a narrow latitude band where Pioneer Venus Orbiter (PVO) altimetry data, line-of-sight (LOS) gravity data, and Venera 15/16 radar images have all been obtained with good resolution. Tellus Regio also has a wide variety of surface morphologic features, elevations ranging up to 2.5 km, and a relatively low LOS gravity anomaly. This area was therefore chosen in order to examine the theoretical stress distributions resulting from various models of compensation of the observed topography. These surface stress distributions are then compared with the surface morphology revealed in the Venera 15/16 radar images. Conclusions drawn from these comparisons will enable constraints to be put on various tectonic parameters relevant to Tellus Regio. The stress distribution is calculated as a function of the topography, the equipotential anomaly, and the assumed model parameters. The topography data is obtained from the PVO altimetry. The equipotential anomaly is estimated from the PVO LOS gravity data. The PVO LOS gravity represents the spacecraft accelerations due to mass anomalies within the planet. These accelerations are measured at various altitudes and angles to the local vertical and therefore do not lend themselves to a straightforward conversion. A minimum variance estimator of the LOS gravity data is calculated, taking into account the various spacecraft altitudes and LOS angles and using the measured PVO topography as an a priori constraint. This results in an estimated equivalent surface mass distribution, from which the equipotential anomaly is determined

  10. The development of surface topography by heavy ion sputtering

    International Nuclear Information System (INIS)

    Whitton, J.L.; Carter, G.

    1981-01-01

    The results of a detailed, systematic investigation of the development of energetic argon ion bombardment induced surface features on polycrystal and single crystal copper are presented. It is shown that the crystal structure itself is the dominant factor deciding the final form of surface topography. The earlier proposed ''necessary conditions'' for development of surface topography, viz. surface impurity, asperities, growth, surface migration and redeposition are shown to be unimportant under the clean conditions of the experiments. (Auth.)

  11. Pitting Corrosion Topography Characteristics and Evolution Laws of LC4 Aluminum Alloy in Service Environment

    Directory of Open Access Journals (Sweden)

    LIU Zhiguo

    2017-08-01

    Full Text Available Aircraft aluminum alloy is easy to initiate pitting corrosion in the service environment, the pitting corrosion topography characteristics could directly affect the fatigue mechanical property of structure material. In order to obtain the pitting corrosion topography characteristics of LC4 aluminum alloy in the service environment, the accelerated corrosion test was carried out along the accelerated corrosion test environment spectrum which imitated the service environment spectrum, and the corrosion topography characteristic parameters of corrosion pit depth H,corrosion pit surface length L and corrosion pit surface width W were defined respectively. During the corrosion test process,the three parameters of typical corrosion pit were successively measured in different equivalent corrosion years for obtaining the corrosion pit damage size data, then the data were analysed through the statistics method and fractal theory. Further more in order to gain the pit topography characteristics in the same equivalent corrosion year and the topography evolution laws during different equivalent corrosion years were gained. The analysis results indicate that LC4 aluminum alloy corrosion pit topography characteristics in the service environment include the following:firstly, the pit topography characteristic parameters conform to the lognormal distributions in the same equivalent corrosion years; secondly,the pit topography characteristic parameters gradually reflect the fractal feature in accordance with the equivalent corrosion year increment, and the pits tend to be shallow, long and moderate wide topography character.

  12. Tectonics and Non-isostatic Topography of the Mariana Trench and Adjacent Plates

    Science.gov (United States)

    Hongyu, L.; Lin, J.; Zhou, Z.; Zhang, F.

    2017-12-01

    Multi-types of geophysical data including multibeam bathymetry, sediment thickness, gravity anomaly, and crustal magnetic age were analyzed to investigate tectonic processes of the Mariana Trench and the surrounding plates. We calculated non-Airy-isostatic topography by removing from the observed bathymetry the effects of sediment loading, thermal subsidence, and Airy local isostatically-compensated topography. The Mariana Trench was found to be associated with a clearly defined zone of negative non-isostatic topography, which was caused by flexural bending of the subducting Pacific plate and with the maximum depth anomaly and flexural bending near the Challenger Deep. In contrast, the Caroline Ridge and Caroline Islands Chain have much more subdued non-isostatic topography, indicating their higher topography is largely compensated by thicker crust. Along the Mariana Trough, the northern and central segments appear to be associated with relatively low magma supply as indicated by the relatively low topography and thin crust. In contrast, the southern Mariana Trough is associated with relatively high magma supply as indicated by the relatively high and smoother topography, an axial high spreading center, and relatively thick crust. The southern end of the Mariana Trough was also found to be associated with positive non-isostatic topographic anomaly, which might be caused by the complex tectonic deformation of the overriding Mariana and Philippine Sea plates and their interaction with the subducting Pacific plate. Analysis further revealed that the southern Mariana Arc, located between the Mariana Trench and Mariana Trough, is associated with positive non-isostatic topographic anomalies, which may be explained by the late stage magmatic loading on the older and thus stronger lithospheric plate of the Mariana volcanic arc.

  13. Can preoperative MR imaging predict optic nerve invasion of retinoblastoma?

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Eo, Hong; Kim, Ji Hye; Yoo, So-Young; Jeon, Tae Yeon

    2012-01-01

    Purpose: To evaluate the accuracy of pre-operative MRI for the detection of optic nerve invasion in retinoblastoma. Materials and methods: Institutional review board approval and informed consent were waived for this retrospective study. A total of 41 patients were included. Inclusion criteria were histologically proven retinoblastoma, availability of diagnostic-quality preoperative MR images acquired during the 4 weeks before surgery, unilateral retinoblastoma, and normal-sized optic nerve. Two radiologists retrospectively reviewed the MR images independently. Five imaging findings (diffuse mild optic nerve enhancement, focal strong optic nerve enhancement, optic sheath enhancement, tumor location, and tumor size) were evaluated against optic nerve invasion of retinoblastoma. The predictive performance of all MR imaging findings for optic nerve invasion was also evaluated by the receiver operating characteristic curve analysis. Results: Optic nerve invasion was histopathologically confirmed in 24% of study population (10/41). The differences in diffuse mild enhancement, focal strong enhancement, optic sheath enhancement, and tumor location between patients with optic nerve invasion and patients without optic nerve invasion were not significant. Tumor sizes were 16.1 mm (SD: 2.2 mm) and 14.9 mm (SD: 3.6 mm) in patients with and without optic nerve involvement, respectively (P = 0.444). P-Values from binary logistic regression indicated that all five imaging findings were not significant predictors of tumor invasion of optic nerve. The AUC values of all MR imaging findings for the prediction of optic nerve invasion were 0.689 (95% confidence interval: 0.499–0.879) and 0.653 (95% confidence interval: 0.445–0.861) for observer 1 and observer 2, respectively. Conclusion: Findings of MRI in patients with normal-sized optic nerves have limited usefulness in preoperatively predicting the presence of optic nerve invasion in retinoblastoma.

  14. Can preoperative MR imaging predict optic nerve invasion of retinoblastoma?

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kyoung Doo, E-mail: kdsong0308@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Eo, Hong, E-mail: rtombow@gmail.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Kim, Ji Hye, E-mail: jhkate.kim@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Yoo, So-Young, E-mail: sy1131.yoo@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Jeon, Tae Yeon, E-mail: hathor97.jeon@samsung.com [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of)

    2012-12-15

    Purpose: To evaluate the accuracy of pre-operative MRI for the detection of optic nerve invasion in retinoblastoma. Materials and methods: Institutional review board approval and informed consent were waived for this retrospective study. A total of 41 patients were included. Inclusion criteria were histologically proven retinoblastoma, availability of diagnostic-quality preoperative MR images acquired during the 4 weeks before surgery, unilateral retinoblastoma, and normal-sized optic nerve. Two radiologists retrospectively reviewed the MR images independently. Five imaging findings (diffuse mild optic nerve enhancement, focal strong optic nerve enhancement, optic sheath enhancement, tumor location, and tumor size) were evaluated against optic nerve invasion of retinoblastoma. The predictive performance of all MR imaging findings for optic nerve invasion was also evaluated by the receiver operating characteristic curve analysis. Results: Optic nerve invasion was histopathologically confirmed in 24% of study population (10/41). The differences in diffuse mild enhancement, focal strong enhancement, optic sheath enhancement, and tumor location between patients with optic nerve invasion and patients without optic nerve invasion were not significant. Tumor sizes were 16.1 mm (SD: 2.2 mm) and 14.9 mm (SD: 3.6 mm) in patients with and without optic nerve involvement, respectively (P = 0.444). P-Values from binary logistic regression indicated that all five imaging findings were not significant predictors of tumor invasion of optic nerve. The AUC values of all MR imaging findings for the prediction of optic nerve invasion were 0.689 (95% confidence interval: 0.499–0.879) and 0.653 (95% confidence interval: 0.445–0.861) for observer 1 and observer 2, respectively. Conclusion: Findings of MRI in patients with normal-sized optic nerves have limited usefulness in preoperatively predicting the presence of optic nerve invasion in retinoblastoma.

  15. MRI-guided laser-induced thermotherapy (LITT) of liver metastases: clinical evaluation

    International Nuclear Information System (INIS)

    Vogl, T.J.; Weinhold, N.; Mueller, P.; Mack, M.; Scholz, W.; Philipp, C.; Roggan, A.; Felix, R.

    1996-01-01

    The goal was to perform an evaluation of MRI-guided laser-induced thermotherapy (LITT) of liver metastases as a clinical method. In a prospective study, 50 patients with liver metastases of colorectal carcinoma (35 patients), or other primary tumors (15 patients) were treated with LITT. For preparation and intermittent controls of therapy, standardized MRI examinations were made. Online monitoring during the the LITT was done with temperature-sensitive T1-weighted sequences (FLASH-2D, TurboFLASH). All in all, 83 metastases of a volume between 1 and 282 cubic centimeters (median = ± 10 cm 3 ) were treated.During performance of the LITT, a decrease of signal intensity in the thermosensitive sequences was measured for the application area, and was correlated with fluorine-optical temperature measurements. The MRI-guided LITT is a novel, potential modality for treatment of liver metastases, and poses only minimal clinical risks. (orig./VHE) [de

  16. Influence of dynamic topography on landscape evolution and passive continental margin stratigraphy

    Science.gov (United States)

    Ding, Xuesong; Salles, Tristan; Flament, Nicolas; Rey, Patrice

    2017-04-01

    Quantifying the interaction between surface processes and tectonics/deep Earth processes is one important aspect of landscape evolution modelling. Both observations and results from numerical modelling indicate that dynamic topography - a surface expression of time-varying mantle convection - plays a significant role in shaping landscape through geological time. Recent research suggests that dynamic topography also has non-negligible effects on stratigraphic architecture by modifying accommodation space available for sedimentation. In addition, dynamic topography influences the sediment supply to continental margins. We use Badlands to investigate the evolution of a continental-scale landscape in response to transient dynamic uplift or subsidence, and to model the stratigraphic development on passive continental margins in response to sea-level change, thermal subsidence and dynamic topography. We consider a circularly symmetric landscape consisting of a plateau surrounded by a gently sloping continental plain and a continental margin, and a linear wave of dynamic topography. We analyze the evolution of river catchments, of longitudinal river profiles and of the χ values to evaluate the dynamic response of drainage systems to dynamic topography. We calculate the amount of cumulative erosion and deposition, and sediment flux at shoreline position, as a function of precipitation rate and erodibility coefficient. We compute the stratal stacking pattern and Wheeler diagram on vertical cross-sections at the continental margin. Our results indicate that dynamic topography 1) has a considerable influence on drainage reorganization; 2) contributes to shoreline migration and the distribution of depositional packages by modifying the accommodation space; 3) affects sediment supply to the continental margin. Transient dynamic topography contributes to the migration of drainage divides and to the migration of the mainstream in a drainage basin. The dynamic uplift

  17. Direct characterization of ultraviolet-light-induced refractive index structures by scanning near-field optical microscopy

    DEFF Research Database (Denmark)

    Svalgaard, Mikael; Madsen, S.; Hvam, Jørn Märcher

    1998-01-01

    We have applied a reflection scanning near-field optical microscope to directly probe ultraviolet (UV)-light-induced refractive index structures in planar glass samples. This technique permits direct comparison between topography and refractive index changes (10(-5)-10(-3)) with submicrometer...

  18. Acquisition of an Underway CTD System for the Flow Encountering Abrupt Topography DRI

    Science.gov (United States)

    2015-09-30

    Acquisition of an Underway CTD System for the Flow Encountering Abrupt Topography DRI T. M. Shaun Johnston Scripps Institution of Oceanography...westward flow in the North Equatorial Current (NEC) encounters tall, steep, submarine topography and islands. During the Flow Encountering Abrupt... Topography (FLEAT) DRI, investigators will determine: • Whether appreciable energy/momentum is lost from the large-scale NEC flow to smaller scales and

  19. MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto [Oulu University Hospital, Department of Radiology, Oulu (Finland); Lakovaara, Martti [Oulu Deaconess Institute, Department of Surgery, Oulu (Finland); Hyvoenen, Pekka; Lehenkari, Petri [Oulu University Hospital, Department of Surgery, Oulu (Finland)

    2011-06-15

    The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)

  20. MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee

    International Nuclear Information System (INIS)

    Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto; Lakovaara, Martti; Hyvoenen, Pekka; Lehenkari, Petri

    2011-01-01

    The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)

  1. Light source for synchrotron radiation x-ray topography study at Beijing Synchrotron Radiation Laboratory (BSRL)

    International Nuclear Information System (INIS)

    Zhao Jiyong; Jiang Jianhua; Tian Yulian

    1992-01-01

    Characteristics of the synchrotron radiation source for X-ray topography study at Beijing Synchrotron Radiation Laboratory (BSRL) is described, local geometrical resolution of topographies is discussed, and the diffracting intensities of white beam topography is given

  2. Parametric uncertainty in optical image modeling

    Science.gov (United States)

    Potzick, James; Marx, Egon; Davidson, Mark

    2006-10-01

    Optical photomask feature metrology and wafer exposure process simulation both rely on optical image modeling for accurate results. While it is fair to question the accuracies of the available models, model results also depend on several input parameters describing the object and imaging system. Errors in these parameter values can lead to significant errors in the modeled image. These parameters include wavelength, illumination and objective NA's, magnification, focus, etc. for the optical system, and topography, complex index of refraction n and k, etc. for the object. In this paper each input parameter is varied over a range about its nominal value and the corresponding images simulated. Second order parameter interactions are not explored. Using the scenario of the optical measurement of photomask features, these parametric sensitivities are quantified by calculating the apparent change of the measured linewidth for a small change in the relevant parameter. Then, using reasonable values for the estimated uncertainties of these parameters, the parametric linewidth uncertainties can be calculated and combined to give a lower limit to the linewidth measurement uncertainty for those parameter uncertainties.

  3. Visual pathway abnormalities were found in most multiple sclerosis patients despite history of previous optic neuritis

    Directory of Open Access Journals (Sweden)

    Stella Maris Costa Castro

    2013-07-01

    Full Text Available Objective It was to investigate visual field (VF abnormalities in a group of multiple sclerosis (MS patients in the remission phase and the presence of magnetic resonance imaging (MRI lesions in the optic radiations. Methods VF was assessed in 60 participants (age range 20-51 years: 35 relapsing-remitting MS patients [20 optic neuritis (+, 15 optic neuritis (-] and 25 controls. MRI (3-Tesla was obtained in all patients. Results Visual parameters were abnormal in MS patients as compared to controls. The majority of VF defects were diffuse. All patients except one had posterior visual pathways lesions. No significant difference in lesion number, length and distribution was noted between patients with and without history of optic neuritis. One patient presented homonymous hemianopsia. Conclusion Posterior visual pathway abnormalities were found in most MS patients despite history of previous optic neuritis.

  4. Reformation and utilization of complicated topography for a uranium mill

    International Nuclear Information System (INIS)

    Liu Taoan; Zhou Xinghuo; Lv Junwen

    2004-01-01

    It is successful for how to reform and utilized complicated topography in the design of general plan and transport for technological reformation of a uranium mill. The unfavorable factors of complicated topography are turned into favorable ones. The general plan is designed compactly and the land is economized. The transport is designed simply and directly. the leaching liquid flows by gravity so that the power is economical

  5. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    Science.gov (United States)

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2017-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually observable image artifact. The targeting accuracy is evaluated with optical tracking system and gelatin phantom under live MRI-guidance with Root Mean Square (RMS) errors of 1.94 and 2.17 mm respectively. Furthermore, we demonstrate that the robot has kinematic redundancy to reach the same target through different paths. This was evaluated in both free space and MRI-guided gelatin phantom trails, with RMS errors of 0.48 and 0.59 mm respectively. As the first of its kind, MRI-guided targeted concentric tube needle placements with ex vivo porcine liver are demonstrated with 4.64 mm RMS error through closed-loop control of the piezoelectrically-actuated robot. PMID:26983842

  6. Optical methods for characterization of surface structures on a nanometer scale

    DEFF Research Database (Denmark)

    Gregersen, Niels

    2007-01-01

    When studying a sample with subwavelength features using conventional microscopy, the diffraction limit sets a lower bound to the resolution achievable. In this work the possiblity of circumventing the diffraction limit by employing a scanning near-field optical microscope (SNOM) to perform...... the characterization is investigated. Experimental SNOM images of the optical field distribution above a deep grating are analyzed with the purpose of identifying the grating topography, and transfer functions describing the coupling of the free-space field to the guided mode of the SNOM fiber are determined...

  7. Improving Beamline X-ray Optics by Analyzing the Damage to Crystallographic Structure

    Energy Technology Data Exchange (ETDEWEB)

    Zientek, John; Maj, Jozef; Navrotski, Gary; Srajer, George; Harmata, Charles; Maj, Lech; Lazarski, Krzysztof; Mikula, Stanislaw

    2015-01-02

    The mission of the X-ray Characterization Laboratory in the X-ray Science Division (XSD) at the Advanced Photon Source (APS) is to support both the users and the Optics Fabrication Facility that produces high performance optics for synchrotron X-ray beamlines. The Topography Test Unit (TTU) in the X-ray Lab has been successfully used to characterize diffracting crystals and test monochromators by quantifying residual surface stresses. This topographic method has also been adapted for testing standard X-ray mirrors, characterizing concave crystal optics and in principle, can be used to visualize residual stresses on any optic made from single crystalline material. The TTU has been instrumental in quantitatively determining crystal mounting stresses which are mechanically induced by positioning, holding, and cooling fixtures. It is this quantitative aspect that makes topography so useful since the requirements and responses for crystal optics and X-ray mirrors are quite different. In the case of monochromator crystals, even small residual or induced stresses, on the order of tens of kPa, can cause detrimental distortions to the perfect crystal rocking curves. Mirrors, on the other hand, are much less sensitive to induced stresses where stresses that are an order of magnitude greater can be tolerated. This is due to the fact that the surface rather than the lattice-spacing determines a mirror’s performance. For the highly sensitive crystal optics, it is essential to measure the in-situ rocking curves using topographs as mounting fixtures are adjusted. In this way, high heat-load monochromator crystals can be successfully mounted with minimum stress. Topographical analysis has been shown to be a highly effective method to visualize and quantify the distribution of stresses, to help identify methods that mitigate stresses, and most notably to improve diffractive crystal optic rocking curves.

  8. Age and Prematurity of the Alps Derived from Topography

    Science.gov (United States)

    Hergarten, S.; Wagner, T.; Stüwe, K.

    2010-09-01

    The European Alps are one of the best studied mountain ranges on Earth, but yet the age of their topography is almost unknown. Even their relative stage of evolution is unclear: Are the Alps still growing, in a steady state or already decaying, and is there a significant difference between Western and Eastern Alps? Using a new geomorphic parameter we analyze the topography of the Alps and provide one of the first quantitative constraints demonstrating that the range is still in its infancy: In contrast to several other mountain ranges, the Alps have still more than half of their evolution to a geomorphic steady state to go. Combining our results with sediment budget data from the surrounding basins we infer that the formation of the present topography began only 5-6 million years ago. Our results question the apparent consensus that the topographic evolution is distributed over much of the Miocene and might give new impulses to the reconstruction of paleoclimate in Central Europe.

  9. Joint optimization of source, mask, and pupil in optical lithography

    Science.gov (United States)

    Li, Jia; Lam, Edmund Y.

    2014-03-01

    Mask topography effects need to be taken into consideration for more advanced resolution enhancement techniques in optical lithography. However, rigorous 3D mask model achieves high accuracy at a large computational cost. This work develops a combined source, mask and pupil optimization (SMPO) approach by taking advantage of the fact that pupil phase manipulation is capable of partially compensating for mask topography effects. We first design the pupil wavefront function by incorporating primary and secondary spherical aberration through the coefficients of the Zernike polynomials, and achieve optimal source-mask pair under the condition of aberrated pupil. Evaluations against conventional source mask optimization (SMO) without incorporating pupil aberrations show that SMPO provides improved performance in terms of pattern fidelity and process window sizes.

  10. Influence of cell-internalization on relaxometric, optical and compositional properties of targeted paramagnetic quantum dot micelles

    NARCIS (Netherlands)

    Starmans, L. W. E.; Kok, M. B.; Sanders, H. M. H. F.; Zhao, Y.; Donegá, C. de Mello; Meijerink, A.; Mulder, W. J. M.; Grüll, H.; Strijkers, G. J.; Nicolay, K.

    2011-01-01

    Quantum dot micelles (pQDs) with a paramagnetic coating are promising nanoparticles for bimodal molecular imaging. Their bright fluorescence allows for optical detection, while their Gd payload enables visualization with contrast-enhanced MRI. A popular approach in molecular MRI is the targeting of

  11. Wallerian Degeneration Beyond the Corticospinal Tracts: Conventional and Advanced MRI Findings.

    Science.gov (United States)

    Chen, Yin Jie; Nabavizadeh, Seyed Ali; Vossough, Arastoo; Kumar, Sunil; Loevner, Laurie A; Mohan, Suyash

    2017-05-01

    Wallerian degeneration (WD) is defined as progressive anterograde disintegration of axons and accompanying demyelination after an injury to the proximal axon or cell body. Since the 1980s and 1990s, conventional magnetic resonance imaging (MRI) sequences have been shown to be sensitive to changes of WD in the subacute to chronic phases. More recently, advanced MRI techniques, such as diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), have demonstrated some of earliest changes attributed to acute WD, typically on the order of days. In addition, there is increasing evidence on the value of advanced MRI techniques in providing important prognostic information related to WD. This article reviews the utility of conventional and advanced MRI techniques for assessing WD, by focusing not only on the corticospinal tract but also other neural tracts less commonly thought of, including corticopontocerebellar tract, dentate-rubro-olivary pathway, posterior column of the spinal cord, corpus callosum, limbic circuit, and optic pathway. The basic anatomy of these neural pathways will be discussed, followed by a comprehensive review of existing literature supported by instructive clinical examples. The goal of this review is for readers to become more familiar with both conventional and advanced MRI findings of WD involving important neural pathways, as well as to illustrate increasing utility of advanced MRI techniques in providing important prognostic information for various pathologies. Copyright © 2016 by the American Society of Neuroimaging.

  12. A Technique for Generating Volumetric Cine MRI (VC-MRI)

    Science.gov (United States)

    Harris, Wendy; Ren, Lei; Cai, Jing; Zhang, You; Chang, Zheng; Yin, Fang-Fang

    2016-01-01

    Purpose To develop a technique to generate on-board volumetric-cine MRI (VC-MRI) using patient prior images, motion modeling and on-board 2D-cine MRI. Methods One phase of a 4D-MRI acquired during patient simulation is used as patient prior images. 3 major respiratory deformation patterns of the patient are extracted from 4D-MRI based on principal-component-analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2D-cine MRI. The method was evaluated using both XCAT simulation of lung cancer patients and MRI data from four real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using Volume-Percent-Difference(VPD), Center-of-Mass-Shift(COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest(ROI) selection, patient breathing pattern change and noise on the estimation accuracy were also evaluated. Results Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was on average 8.43±1.52% and the COMS was on average 0.93±0.58mm across all time-steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR=20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions Preliminary studies demonstrated the

  13. Mandibular molar crown-topography, a biological predisposing ...

    African Journals Online (AJOL)

    Mandibular molar crown-topography, a biological predisposing factor to development of caries – a post-mortem analysis of 2500 extracted lower permanent molars at the dental centre, University of Benin teaching hospital.

  14. MRI Primer

    International Nuclear Information System (INIS)

    Oldendorf, W.; Oldendorf, W. Jr.

    1991-01-01

    Designed for studies, radiologists, and clinicians at all levels of training, this book provides a basic introduction to the principles, physics, and instrumentation of magnetic resonance imaging. The fundamental concepts that are essential for the optimal clinical use of MRI are thoroughly explained in easily accessible terms. To facilitate the reader's comprehension, the material is presented nonmathematically, using no equations and a minimum of symbols and abbreviations. MRI Primer presents a clear account of the phenomenon of nuclear magnetic resonance and the use of gradient magnetic fields to create clinically useful images of cross-sectional slices. Close attention is given to the magnetization vector as a means of expressing nuclear behavior, the role of T 1 and T 2 weighing in imaging, the use of contrast agents, and the pulse sequences most often used in clinical practice, as well as to the relative capabilities and limitations of MRI and CT. The basic hardware components of an MRI scanner are described in detail. Sample MRI scans illustrate how MRI characterizes tissue. An appendix provides a brief introduction to quantum processes in MRI

  15. Airborne laser altimeter measurements of landscape topography

    International Nuclear Information System (INIS)

    Ritchie, J.C.

    1995-01-01

    Measurements of topography can provide a wealth of information on landscape properties for managing hydrologic and geologic systems and conserving natural and agricultural resources. This article discusses the application of an airborne laser altimeter to measure topography and other landscape surface properties. The airborne laser altimeter makes 4000 measurements per second with a vertical recording resolution of 5 cm. Data are collected digitally with a personal computer. A video camera, borehole sighted with the laser, records an image for locating flight lines. GPS data are used to locate flight line positions on the landscape. Laser data were used to measure vegetation canopy topography, height, cover, and distribution and to measure microtopography of the land surface and gullies with depths of 15–20 cm. Macrotopography of landscape profiles for segments up to 4 km were in agreement with available topographic maps but provided more detail. Larger gullies with and without vegetation, and stream channel cross sections and their associated floodplains have also been measured and reported in other publications. Landscape segments for any length could be measured for either micro- or macrotopography. Airborne laser altimeter measurements of landscape profiles can provide detailed information on landscape properties or specific needs that will allow better decisions on the design and location of structures (i.e., roads, pipe, and power lines) and for improving the management and conservation of natural and agricultural landscapes. (author)

  16. There is less MRI brain lesions and no characteristic MRI Brain findings in IIDDs patients with positive AQP4 serology among Malaysians.

    Science.gov (United States)

    Abdullah, Suhailah; Fadzli, Farhana; Ramli, Norlisah; Tan, Chong Tin

    2017-02-01

    The recently introduced International Consensus diagnostic criteria for diagnosis of neuromyelitis spectrum disorder include patients who are seronegative for AQP4 antibody. The criteria are dependent on typical MRI changes in the spinal cord, optic nerve and brain. This study aims to determine whether there are significant differences in the MRI brain images between AQP4 positive and negative patients with IIDDs. MRI brain of patients with a diagnosis of IIDDs presented to the Hospital from 2010 to 2015 was analysed. The MRI was assessed by 2 radiologists blinded to the AQP4 status, on features said to be typical of NMOSD and MS. Thirty nine patients fulfilled the criteria and were included in the study. They consisted of 19 AQP4 seropositive and 20 AQP4 seronegative patients. The mean age was older (37.0 vs. 28.8 years) among the AQP4 positive group. The majority of the patients were ethnic Chinese (72%), followed by the Malays and Indians. Those with AQP4 seropositive status generally has less brain lesions, and significantly less fulfilling the McDonald DIS criteria as compared to those with AQP4 seronegative status (15.8% vs. 60.0%, p=0.005). None of the seven cerebral MRI features highlighted in NMOSD 2015 diagnostic criteria, said to be characteristic of NMOSD was more common among the AQP4 positive patients. These features were in fact seen less frequently among the AQP4 seropositive patients. An example was the extensive hemispheric lesion seen in 10.5% of AQP4 seropositive patients vs. 45% of that AQP4 seronegative group. There was no characteristic MRI brain features in the Malaysian AQP4 seropositive IIDD patients versus those who are seronegative. This could be a reflection of ethnical difference. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Topography and instability of monolayers near domain boundaries

    International Nuclear Information System (INIS)

    Diamant, H.; Witten, T. A.; Ege, C.; Gopal, A.; Lee, K. Y. C.

    2001-01-01

    We theoretically study the topography of a biphasic surfactant monolayer in the vicinity of domain boundaries. The differing elastic properties of the two phases generally lead to a nonflat topography of 'mesas,' where domains of one phase are elevated with respect to the other phase. The mesas are steep but low, having heights of up to 10 nm. As the monolayer is laterally compressed, the mesas develop overhangs and eventually become unstable at a surface tension of about K(δc 0 ) 2 (δc 0 being the difference in spontaneous curvature and K a bending modulus). In addition, the boundary is found to undergo a topography-induced rippling instability upon compression, if its line tension is smaller than about Kδc 0 . The effect of diffuse boundaries on these features and the topographic behavior near a critical point are also examined. We discuss the relevance of our findings to several experimental observations related to surfactant monolayers: (i) small topographic features recently found near domain boundaries; (ii) folding behavior observed in mixed phospholipid monolayers and model lung surfactants; (iii) roughening of domain boundaries seen under lateral compression; (iv) the absence of biphasic structures in tensionless surfactant films

  18. The Effects of Micro- and Nano-Topography on Cells

    DEFF Research Database (Denmark)

    Kolind, Kristian

    2013-01-01

    the effect of topography on cells has received much attention understanding how important this is for the rational design of bio-interfaces. Nevertheless, there is still a limited understanding of the effect of topography on cells making it impossible to tailor a biomaterial with specific cellular activity......Cells continuously make decisions on what proteins to express, and when to divide, differentiate and commit suicide, through a complex network of intracellular processes. The signals that determine the cellular processes reside within the extracellular matrix. They involve soluble signaling...

  19. Observation of magnetic domains using a reflection mode scanning near-field optical microscope

    OpenAIRE

    Durkam, C.; Shvets, I.V.; Lodder, J.C.

    1997-01-01

    It is demonstrated that it is possible to image magnetic domains with a resolution of better than 60 nm with the Kerr effect in a reflection-mode scanning near-field optical microscope. Images taken of tracks of thermomagnetically prewritten bits in a Co/Pt multilayer structure magnetized out-of plane showed optical features in a track pattern whose appearance was determined by the position of an analyzer in front of the photomultiplier tube. These features were not apparent in the topography...

  20. Determining relative contributions of vegetation and topography to burn severity from LANDSAT imagery.

    Science.gov (United States)

    Wu, Zhiwei; He, Hong S; Liang, Yu; Cai, Longyan; Lewis, Bernard J

    2013-10-01

    Fire is a dominant process in boreal forest landscapes and creates a spatial patch mosaic with different burn severities and age classes. Quantifying effects of vegetation and topography on burn severity provides a scientific basis on which forest fire management plans are developed to reduce catastrophic fires. However, the relative contribution of vegetation and topography to burn severity is highly debated especially under extreme weather conditions. In this study, we hypothesized that relationships of vegetation and topography to burn severity vary with fire size. We examined this hypothesis in a boreal forest landscape of northeastern China by computing the burn severity of 24 fire patches as the difference between the pre- and post-fire Normalized Difference Vegetation Index obtained from two Landsat TM images. The vegetation and topography to burn severity relationships were evaluated at three fire-size levels of small (1,000 ha, n = 3). Our results showed that vegetation and topography to burn severity relationships were fire-size-dependent. The burn severity of small fires was primary controlled by vegetation conditions (e.g., understory cover), and the burn severity of large fires was strongly influenced by topographic conditions (e.g., elevation). For moderate fires, the relationships were complex and indistinguishable. Our results also indicated that the pattern trends of relative importance for both vegetation and topography factors were not dependent on fire size. Our study can help managers to design fire management plans according to vegetation characteristics that are found important in controlling burn severity and prioritize management locations based on the relative importance of vegetation and topography.

  1. Calibration of the geometrical characteristics of areal surface topography measuring instruments

    International Nuclear Information System (INIS)

    Giusca, C L; Leach, R K; Helery, F; Gutauskas, T

    2011-01-01

    The use of areal surface topography measuring instruments has increased significantly over the past ten years as industry starts to embrace the use of surface structuring to affect the function of a component. This has led to a range of areal surface topography measuring instruments being developed and becoming available commercially. For such instruments to be used as part of quality control during production, it is essential for them to be calibrated according to international standards. The ISO 25178 suite of specification standards on areal surface topography measurement presents a series of tests that can be used to calibrate the metrological characteristics of an areal surface topography measuring instrument. Calibration artefacts and test procedures have been developed that are compliant with ISO 25178. The material measures include crossed gratings, resolution artefacts and pseudorandom surfaces. Traceability is achieved through the NPL Areal Instrument - a primary stylus-based instrument that uses laser interferometers to measure the displacement of the stylus tip. Good practice guides on areal calibration have also been drafted for stylus instruments, coherence scanning interferometers, scanning confocal microscopes and focus variation instruments.

  2. Metabolic topography of autoimmune non-paraneoplastic encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Madhavi; Roy, Shambo Guha; Parida, Girish Kumar; Damle, Nishikant; Shamim, Shamim Ahmed; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Tripathi, Manjari; Ihtisham, Kavish; Dash, Deepa [All India Institute of Medical Sciences, Department of Neurology, Cardiothoracic and Neurosciences Centre, New Delhi (India)

    2018-02-15

    F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) is emerging to be a useful tool in supporting the diagnosis of AIE. In this study, we describe the metabolic patterns on F-18 FDG PET imaging in AIE. Twenty-four antibody-positive patients (anti-NMDA-15, anti-VGKC/LGI1-6, and anti-GAD-3), 14 females and 10 males, with an age range of 2-83 years were included in this study. Each PET study was evaluated visually for the presence of hypometabolism or hypermetabolism and semiquantitatively using Cortex ID (GE) and Scenium (Siemens) by measuring regional Z-scores. These patterns were correlated with corresponding antibody positivity once available. Visually, a pattern of hypometabolism, hypermetabolism, or both in various spatial distributions was appreciated in all 24 patients. On quantitative analysis using scenium parietal and occipital lobes showed significant hypometabolism with median Z-score of -3.8 (R) and -3.7 (L) and -2.2 (R) and -2.5 (L) respectively. Two-thirds (16/24) showed significant hypermetabolism involving the basal ganglia with median Z-score of 2.4 (R) and 3.0 (L). Similarly on Cortex ID, the median Z-score for hypometabolism in parietal and occipital lobes was -2.2 (R) and -2.4 (L) and -2.6 (R) and -2.4 (L) respectively, while subcortical regions were not evaluated. MRI showed signal alterations in only 11 of these patients. There is heterogeneity in metabolic topography of AIE which is characterized by hypometabolism most commonly involving the parietal and occipital cortices and hypermetabolism most commonly involving the basal ganglia. Scenium analysis using regional Z-scores can complement visual evaluation for demonstration of these metabolic patterns on FDG PET. (orig.)

  3. Metabolic topography of autoimmune non-paraneoplastic encephalitis.

    Science.gov (United States)

    Tripathi, Madhavi; Tripathi, Manjari; Roy, Shambo Guha; Parida, Girish Kumar; Ihtisham, Kavish; Dash, Deepa; Damle, Nishikant; Shamim, Shamim Ahmed; Bal, Chandrasekhar

    2018-02-01

    F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) is emerging to be a useful tool in supporting the diagnosis of AIE. In this study, we describe the metabolic patterns on F-18 FDG PET imaging in AIE. Twenty-four antibody-positive patients (anti-NMDA-15, anti-VGKC/LGI1-6, and anti-GAD-3), 14 females and 10 males, with an age range of 2-83 years were included in this study. Each PET study was evaluated visually for the presence of hypometabolism or hypermetabolism and semiquantitatively using Cortex ID (GE) and Scenium (Siemens) by measuring regional Z-scores. These patterns were correlated with corresponding antibody positivity once available. Visually, a pattern of hypometabolism, hypermetabolism, or both in various spatial distributions was appreciated in all 24 patients. On quantitative analysis using scenium parietal and occipital lobes showed significant hypometabolism with median Z-score of -3.8 (R) and -3.7 (L) and -2.2 (R) and -2.5 (L) respectively. Two-thirds (16/24) showed significant hypermetabolism involving the basal ganglia with median Z-score of 2.4 (R) and 3.0 (L). Similarly on Cortex ID, the median Z-score for hypometabolism in parietal and occipital lobes was -2.2 (R) and -2.4 (L) and -2.6 (R) and -2.4 (L) respectively, while subcortical regions were not evaluated. MRI showed signal alterations in only 11 of these patients. There is heterogeneity in metabolic topography of AIE which is characterized by hypometabolism most commonly involving the parietal and occipital cortices and hypermetabolism most commonly involving the basal ganglia. Scenium analysis using regional Z-scores can complement visual evaluation for demonstration of these metabolic patterns on FDG PET.

  4. Metabolic topography of autoimmune non-paraneoplastic encephalitis

    International Nuclear Information System (INIS)

    Tripathi, Madhavi; Roy, Shambo Guha; Parida, Girish Kumar; Damle, Nishikant; Shamim, Shamim Ahmed; Bal, Chandrasekhar; Tripathi, Manjari; Ihtisham, Kavish; Dash, Deepa

    2018-01-01

    F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) is emerging to be a useful tool in supporting the diagnosis of AIE. In this study, we describe the metabolic patterns on F-18 FDG PET imaging in AIE. Twenty-four antibody-positive patients (anti-NMDA-15, anti-VGKC/LGI1-6, and anti-GAD-3), 14 females and 10 males, with an age range of 2-83 years were included in this study. Each PET study was evaluated visually for the presence of hypometabolism or hypermetabolism and semiquantitatively using Cortex ID (GE) and Scenium (Siemens) by measuring regional Z-scores. These patterns were correlated with corresponding antibody positivity once available. Visually, a pattern of hypometabolism, hypermetabolism, or both in various spatial distributions was appreciated in all 24 patients. On quantitative analysis using scenium parietal and occipital lobes showed significant hypometabolism with median Z-score of -3.8 (R) and -3.7 (L) and -2.2 (R) and -2.5 (L) respectively. Two-thirds (16/24) showed significant hypermetabolism involving the basal ganglia with median Z-score of 2.4 (R) and 3.0 (L). Similarly on Cortex ID, the median Z-score for hypometabolism in parietal and occipital lobes was -2.2 (R) and -2.4 (L) and -2.6 (R) and -2.4 (L) respectively, while subcortical regions were not evaluated. MRI showed signal alterations in only 11 of these patients. There is heterogeneity in metabolic topography of AIE which is characterized by hypometabolism most commonly involving the parietal and occipital cortices and hypermetabolism most commonly involving the basal ganglia. Scenium analysis using regional Z-scores can complement visual evaluation for demonstration of these metabolic patterns on FDG PET. (orig.)

  5. Diffusion processes in bombardment-induced surface topography

    International Nuclear Information System (INIS)

    Robinson, R.S.

    1984-01-01

    The bombardment of surfaces with moderate energy ions can lead to the development of various micron-sized surface structures. These structures include ridges, ledges, flat planes, pits and cones. The causal phenomena in the production of these features are sputtering, ion reflection, redeposition of sputtered material, and surface diffusion of both impurity and target-atom species. The authors concentrate on the formation of ion bombardment-induced surface topography wherein surface diffusion is a dominant process. The most thoroughly understood aspect of this topography development is the generation of cone-like structures during sputtering. The formation of cones during sputtering has been attributed to three effects. These are: (1) the presence of asperities, defects, or micro-inclusions in the surface layers, (2) the presence of impurities on the surfaces, and (3) particular crystal orientations. (Auth.)

  6. Role of Cigarette Sensory Cues in Modifying Puffing Topography

    Science.gov (United States)

    Rees, Vaughan W.; Kreslake, Jennifer M.; Wayne, Geoffrey Ferris; O Connor, Richard J.; Cummings, K. Michael; Connolly, Gregory N.

    2012-01-01

    Background Human puffing topography promotes tobacco dependence by ensuring nicotine delivery, but the factors that determine puffing behavior are not well explained by existing models. Chemosensory cues generated by variations in cigarette product design features may serve as conditioned cues to allow the smoker to optimize nicotine delivery by adjusting puffing topography. Internal tobacco industry research documents were reviewed to understand the influence of sensory cues on puffing topography, and to examine how the tobacco industry has designed cigarettes, including modified risk tobacco products (MRTPs), to enhance puffing behavior to optimize nicotine delivery and product acceptability. Methods Relevant internal tobacco industry documents were identified using systematic searching with key search terms and phrases, and then snowball sampling method was applied to establish further search terms. Results Modern cigarettes are designed by cigarette manufacturers to provide sensory characteristics that not only maintain appeal, but provide cues which inform puffing intensity. Alterations in the chemosensory cues provided in tobacco smoke play an important role in modifying smoking behavior independently of the central effects of nicotine. Conclusions An associative learning model is proposed to explain the influence of chemosensory cues on variation in puffing topography. These cues are delivered via tobacco smoke and are moderated by design features and additives used in cigarettes. The implications for regulation of design features of modified risk tobacco products, which may act to promote intensive puffing while lowering risk perceptions, are discussed. PMID:22365895

  7. [Influence of different surface treatments on porcelain surface topography].

    Science.gov (United States)

    Tai, Yinxia; Zhu, Xianchun; Sen, Yan; Liu, Chang; Zhang, Xian; Shi, Xueming

    2013-02-01

    To evaluate the influence of different surface treatments on porcelain surface topography. Metal ceramic prostheses in 6 groups were treated according to the different surface treatment methods, and the surface topography was observed through scanning electron microscope (SEM). Group A was the control one (untreated), group B was etched by 9.6% hydrofluoric acid(HF), group C was deglazed by grinding and then etched by 9.6% HF, group D was treated with Nd: YAG laser irradiation(0.75 W) and HF etching, group E was treated with Nd: YAG laser irradiation (1.05 W) and HF etching, and group F was treated with laser irradiation (1.45 W) and HF etching. Surface topography was different in different groups. A lot of inerratic cracks with the shapes of rhombuses and grid, and crater with a shape of circle were observed on the ceramic surface after treatment with energy parameters of 1.05 W Nd: YAG laser irradiation and 9.6% HF etching (group E). Surface topography showed a lot of concaves on the inner wall of the cracks, and the concaves with diameter of 1-5 microm could be observed on the inner wall of the holes, which had a diameter of 20 microm under SEM. The use of Nd: YAG laser irradiation with the energy parameters of 1.05 W and the HF with a concentration of 9.6% can evenly coarsen the porcelain surface, that is an effective surface treatment method.

  8. Linking topography to tonotopy in the mouse auditory thalamocortical circuit

    DEFF Research Database (Denmark)

    Hackett, Troy A; Rinaldi Barkat, Tania; O'Brien, Barbara M J

    2011-01-01

    The mouse sensory neocortex is reported to lack several hallmark features of topographic organization such as ocular dominance and orientation columns in primary visual cortex or fine-scale tonotopy in primary auditory cortex (AI). Here, we re-examined the question of auditory functional topography...... the tonotopic axis in the slice produced an orderly shift of voltage-sensitive dye (VSD) signals along the AI tonotopic axis, demonstrating topography in the mouse thalamocortical circuit that is preserved in the slice. However, compared with BF maps of neuronal spiking activity, the topographic order...... of subthreshold VSD maps was reduced in layer IV and even further degraded in layer II/III. Therefore, the precision of AI topography varies according to the source and layer of the mapping signal. Our findings further bridge the gap between in vivo and in vitro approaches for the detailed cellular study...

  9. Large band gaps of water waves through two-dimensional periodic topography

    International Nuclear Information System (INIS)

    Yang Shaohua; Wu Fugen; Zhong Huilin; Zhong Lanhua

    2006-01-01

    In this Letter, the band structures and band gaps of liquid surface waves propagating over two-dimensional periodic topography was investigated by plane-waves expansion method. The periodic topography drilled by square hollows with square lattice was considered. And the effects of the filling fraction and the orientation of bottom-hollows on the band gaps are investigated in detail

  10. Analysis of light scattering from human breast tissue using a custom dual-optical scanning near-field optical microscope.

    Science.gov (United States)

    Kyle, Jennifer Reiber; Kyle, Michael D; Raghavan, Ravi; Budak, Gurer; Ozkan, Cengiz S; Ozkan, Mihrimah

    2011-03-01

    In this paper we introduce a custom scanning near-field optical microscope (SNOM) that simultaneously collects reflection and transmission near-field images along with topography. This dual-optical SNOM uses a bent probe, which allows for axial reflection imaging, accurate surface scanning, and easy identification of topographic artifacts. Using this novel dual-optical SNOM, we image desiccated and non-desiccated human breast epithelial tissue. By comparing the simultaneous SNOM images, we isolate the effects of tissue morphology and variations in refractive indices on the forward- and back-scattering of light from the tissue. We find that the reduction in back-scattering from tissue, relative to the glass slide, is caused by dense packing of the scattering sites in the cytoplasm (morphology) in the desiccated tissue and a thin-film of water adhering to the glass slide (refractive index) in the non-desiccated tissue sample. Our work demonstrates the potential of our customized dual-optical SNOM system for label-free tissue diagnostics. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Different ways to handle topography in practical geoid determination

    DEFF Research Database (Denmark)

    Dahl, O.C.; Forsberg, René

    1999-01-01

    In this paper two different methods of how to handle topography in geoid determination is investigated. First method employs the Residual Terrain Model (RTM) remove-restore technique and yields the quasigeoid, whereas the second method is the classical Helmert condensation method, yielding...... the topography was represented by either a detailed (100 m) or a coarse (1000 m) digital terrain model. The inclusion of bathymetry in the terrain model was also investigated. Even if two different methods were used, they produced almost identical results at the 5 cm level in the mountains, but small systematic...

  12. Puffing topography and nicotine intake of electronic cigarette users.

    Directory of Open Access Journals (Sweden)

    Rachel Z Behar

    Full Text Available Prior electronic cigarette (EC topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake.This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake.Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10-15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data.Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff, volume/puff (51 ml/puff, total puff volume (1,579 ml, EC fluid consumption (79.6 mg, flow rate (20 ml/s, and peak flow rate (27 ml/s were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers.EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products.

  13. Puffing Topography and Nicotine Intake of Electronic Cigarette Users

    Science.gov (United States)

    Behar, Rachel Z.; Hua, My; Talbot, Prue

    2015-01-01

    Background Prior electronic cigarette (EC) topography data are based on two video analyses with limited parameters. Alternate methods for measuring topography are needed to understand EC use and nicotine intake. Objectives This study evaluated EC topography with a CReSS Pocket device and quantified nicotine intake. Methods Validation tests on pressure drop, flow rate, and volume confirmed reliable performance of the CReSS Pocket device. Twenty participants used Blu Cigs and V2 Cigs for 10 minute intervals with a 10–15 minute break between brands. Brand order was reversed and repeated within 7 days Data were analyzed to determine puff duration, puff count, volume, flow rate, peak flow, and inter-puff interval. Nicotine intake was estimated from cartomizer fluid consumption and topography data. Results Nine patterns of EC use were identified. The average puff count and inter-puff interval were 32 puffs and 17.9 seconds. All participants, except one, took more than 20 puffs/10 minutes. The averages for puff duration (2.65 seconds/puff), volume/puff (51ml/puff), total puff volume (1,579 ml), EC fluid consumption (79.6 mg), flow rate (20 ml/s), and peak flow rate (27 ml/s) were determined for 10-minute sessions. All parameters except total puff count were significantly different for Blu versus V2 EC. Total volume for Blu versus V2 was four-times higher than for conventional cigarettes. Average nicotine intake for Blu and V2 across both sessions was 1.2 ± 0.5 mg and 1.4 ± 0.7 mg, respectively, which is similar to conventional smokers. Conclusions EC puffing topography was variable among participants in the study, but often similar within an individual between brands or days. Puff duration, inter-puff interval, and puff volume varied from conventional cigarette standards. Data on total puff volume and nicotine intake are consistent with compensatory usage of EC. These data can contribute to the development of a standard protocol for laboratory testing of EC products

  14. Estimating Antarctica land topography from GRACE gravity and ICESat altimetry data

    Science.gov (United States)

    Wu, I.; Chao, B. F.; Chen, Y.

    2009-12-01

    We propose a new method combining GRACE (Gravity Recovery and Climate Experiment) gravity and ICESat (Ice, Cloud, and land Elevation Satellite) altimetry data to estimate the land topography for Antarctica. Antarctica is the fifth-largest continent in the world and about 98% of Antarctica is covered by ice, where in-situ measurements are difficult. Some experimental airborne radar and ground-based radar data have revealed very limited land topography beneath heavy ice sheet. To estimate the land topography for the full coverage of Antarctica, we combine GRACE data that indicate the mass distribution, with data of ICESat laser altimetry that provide high-resolution mapping of ice topography. Our approach is actually based on some geological constraints: assuming uniform densities of the land and ice considering the Airy-type isostasy. In the beginning we construct an initial model for the ice thickness and land topography based on the BEDMAP ice thickness and ICESat data. Thereafter we forward compute the model’s gravity field and compare with the GRACE observed data. Our initial model undergoes the adjustments to improve the fit between modeled results and the observed data. Final examination is done by comparing our results with previous but sparse observations of ice thickness to reconfirm the reliability of our results. As the gravitational inversion problem is non-unique, our estimating result is just one of all possibilities constrained by available data in optimal way.

  15. Topochip: technology for instructing cell fate and morphology via designed surface topography

    NARCIS (Netherlands)

    Hulshof, G.F.B.

    2016-01-01

    The control of biomaterial surface topography is emerging as a tool to influence cells and tissues. Due to a lack a theoretical framework of the underlying molecular mechanisms, high-throughput screening (HTS) technology is valuable to identify and study bioactive surface topographies. To identify

  16. Microcontroller based fibre-optic visual presentation system for multisensory neuroimaging.

    Science.gov (United States)

    Kurniawan, Veldri; Klemen, Jane; Chambers, Christopher D

    2011-10-30

    Presenting visual stimuli in physical 3D space during fMRI experiments carries significant technical challenges. Certain types of multisensory visuotactile experiments and visuomotor tasks require presentation of visual stimuli in peripersonal space, which cannot be accommodated by ordinary projection screens or binocular goggles. However, light points produced by a group of LEDs can be transmitted through fibre-optic cables and positioned anywhere inside the MRI scanner. Here we describe the design and implementation of a microcontroller-based programmable digital device for controlling fibre-optically transmitted LED lights from a PC. The main feature of this device is the ability to independently control the colour, brightness, and timing of each LED. Moreover, the device was designed in a modular and extensible way, which enables easy adaptation for various experimental paradigms. The device was tested and validated in three fMRI experiments involving basic visual perception, a simple colour discrimination task, and a blocked multisensory visuo-tactile task. The results revealed significant lateralized activation in occipital cortex of all participants, a reliable response in ventral occipital areas to colour stimuli elicited by the device, and strong activations in multisensory brain regions in the multisensory task. Overall, these findings confirm the suitability of this device for presenting complex fibre-optic visual and cross-modal stimuli inside the scanner. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. RhoA-Mediated Functions in C3H10T1/2 Osteoprogenitors Are Substrate Topography Dependent.

    Science.gov (United States)

    Ogino, Yoichiro; Liang, Ruiwei; Mendonça, Daniela B S; Mendonça, Gustavo; Nagasawa, Masako; Koyano, Kiyoshi; Cooper, Lyndon F

    2016-03-01

    Surface topography broadly influences cellular responses. Adherent cell activities are regulated, in part, by RhoA, a member of the Rho-family of GTPases. In this study, we evaluated the influence of surface topography on RhoA activity and associated cellular functions. The murine mesenchymal stem cell line C3H10T1/2 cells (osteoprogenitor cells) were cultured on titanium substrates with smooth topography (S), microtopography (M), and nanotopography (N) to evaluate the effect of surface topography on RhoA-mediated functions (cell spreading, adhesion, migration, and osteogenic differentiation). The influence of RhoA activity in the context of surface topography was also elucidated using RhoA pharmacologic inhibitor. Following adhesion, M and N adherent cells developed multiple projections, while S adherent cells had flattened and widespread morphology. RhoA inhibitor induced remarkable longer and thinner cytoplasmic projections on all surfaces. Cell adhesion and osteogenic differentiation was topography dependent with S topography roughness dependent (S topography. Smooth surface adherent cells appear highly sensitive to RhoA function, while nano-scale topography adherent cell may utilize alternative cellular signaling pathway(s) to influence adherent cellular functions regardless of RhoA activity. © 2015 Wiley Periodicals, Inc.

  18. Tuning cell adhesion on polymeric and nanocomposite surfaces: Role of topography versus superhydrophobicity

    Energy Technology Data Exchange (ETDEWEB)

    Zangi, Sepideh [Department of Chemical Engineering, Shahrood Branch, Islamic Azad University, P.O. Box 36155-163, Shahrood (Iran, Islamic Republic of); Hejazi, Iman [Department of Polymer Engineering & Color Technology, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Seyfi, Javad, E-mail: Jseyfi@gmail.com [Department of Chemical Engineering, Shahrood Branch, Islamic Azad University, P.O. Box 36155-163, Shahrood (Iran, Islamic Republic of); Hejazi, Ehsan [Department of Clinical Nutrition and Dietetics, Faculty of Nutrition Sciences and Food Technology, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Khonakdar, Hossein Ali [Department of Polymer Engineering, Faculty of Engineering, South Tehran Branch, Islamic Azad University, P.O. Box 19585-466, Tehran (Iran, Islamic Republic of); Davachi, Seyed Mohammad [School of Chemical Engineering, University of Tehran, P.O. Box 11155-4563, Tehran (Iran, Islamic Republic of)

    2016-06-01

    Development of surface modification procedures which allow tuning the cell adhesion on the surface of biomaterials and devices is of great importance. In this study, the effects of different topographies and wettabilities on cell adhesion behavior of polymeric surfaces are investigated. To this end, an improved phase separation method was proposed to impart various wettabilities (hydrophobic and superhydrophobic) on polypropylene surfaces. Surface morphologies and compositions were characterized by scanning electron microscopy and X-ray photoelectron spectroscopy, respectively. Cell culture was conducted to evaluate the adhesion of 4T1 mouse mammary tumor cells. It was found that processing conditions such as drying temperature is highly influential in cell adhesion behavior due to the formation of an utterly different surface topography. It was concluded that surface topography plays a more significant role in cell adhesion behavior rather than superhydrophobicity since the nano-scale topography highly inhibited the cell adhesion as compared to the micro-scale topography. Such cell repellent behavior could be very useful in many biomedical devices such as those in drug delivery and blood contacting applications as well as biosensors. - Highlights: • A novel method is presented for fabrication of superhydrophobic surfaces. • The presence of nanoparticles in non-solvent bath notably promoted phase separation. • Topography had a more notable impact on cell adhesion than superhydrophobicity. • Nano-scale topographical features highly impeded cell adhesion on polymer surfaces.

  19. Tuning cell adhesion on polymeric and nanocomposite surfaces: Role of topography versus superhydrophobicity

    International Nuclear Information System (INIS)

    Zangi, Sepideh; Hejazi, Iman; Seyfi, Javad; Hejazi, Ehsan; Khonakdar, Hossein Ali; Davachi, Seyed Mohammad

    2016-01-01

    Development of surface modification procedures which allow tuning the cell adhesion on the surface of biomaterials and devices is of great importance. In this study, the effects of different topographies and wettabilities on cell adhesion behavior of polymeric surfaces are investigated. To this end, an improved phase separation method was proposed to impart various wettabilities (hydrophobic and superhydrophobic) on polypropylene surfaces. Surface morphologies and compositions were characterized by scanning electron microscopy and X-ray photoelectron spectroscopy, respectively. Cell culture was conducted to evaluate the adhesion of 4T1 mouse mammary tumor cells. It was found that processing conditions such as drying temperature is highly influential in cell adhesion behavior due to the formation of an utterly different surface topography. It was concluded that surface topography plays a more significant role in cell adhesion behavior rather than superhydrophobicity since the nano-scale topography highly inhibited the cell adhesion as compared to the micro-scale topography. Such cell repellent behavior could be very useful in many biomedical devices such as those in drug delivery and blood contacting applications as well as biosensors. - Highlights: • A novel method is presented for fabrication of superhydrophobic surfaces. • The presence of nanoparticles in non-solvent bath notably promoted phase separation. • Topography had a more notable impact on cell adhesion than superhydrophobicity. • Nano-scale topographical features highly impeded cell adhesion on polymer surfaces.

  20. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2014-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0–10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation. PMID:25126153

  1. Surface topography of cylindrical gear wheels after smoothing in abrasive mass, honing and shot peening

    International Nuclear Information System (INIS)

    Michalski, J; Pawlus, P; Zelasko, W

    2011-01-01

    The present paper presents the analysis of surface topography of gear teeth as the result of final machining processes. Teeth of multiple cylindrical gears shaped by grinding were smoothed in abrasive mass, honed or shot peened. The measurement of gears were made using coordinate measuring machine and 3D surface topography stylus instrument. The following deviations were studied; pitch deviation, total pitches deviations, variation of teeth thickness and deviation of gear radial run-out. Changes in teeth surface topography during machining process were determined. 3D surface topography parameters, surface directionality as well as areal autocorrelation and power spectral density functions were taken into consideration. As the results of the analysis, the best surface topography with regard to gear operational properties was recommended.

  2. Internal scanning method as unique imaging method of optical vortex scanning microscope

    Science.gov (United States)

    Popiołek-Masajada, Agnieszka; Masajada, Jan; Szatkowski, Mateusz

    2018-06-01

    The internal scanning method is specific for the optical vortex microscope. It allows to move the vortex point inside the focused vortex beam with nanometer resolution while the whole beam stays in place. Thus the sample illuminated by the focused vortex beam can be scanned just by the vortex point. We show that this method enables high resolution imaging. The paper presents the preliminary experimental results obtained with the first basic image recovery procedure. A prospect of developing more powerful tools for topography recovery with the optical vortex scanning microscope is discussed shortly.

  3. ATM Coastal Topography-Texas, 2001: UTM Zone 14

    Science.gov (United States)

    Klipp, Emily S.; Nayegandhi, Amar; Brock, John C.; Sallenger, A.H.; Bonisteel, Jamie M.; Yates, Xan; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of lidar-derived first-surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of a portion of the Texas coastline within UTM zone 14, acquired October 12-13, 2001. The datasets are made available for use as a management tool to research scientists and natural-resource managers. An innovative scanning lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning lidar system that measures high-resolution topography of the land surface and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser-ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of lidar data in an interactive or batch mode. Modules for presurvey flight-line definition, flight-path plotting, lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant return within each waveform. ALPS is used

  4. GOSAILT: A hybrid of GOMS and SAILT with topography consideration

    Science.gov (United States)

    Wu, S.; Wen, J.

    2017-12-01

    Heterogeneous terrain significantly complicated the energy, mass and momentum exchange between the atmosphere and terrestrial ecosystem. Understanding of topographic effect on the forest reflectance is critical for biophysical parameters retrieval over rugged area. In this paper, a new hybrid bidirectional reflectance distribution function (BRDF) model of geometric optical mutual shadowing and scattering-from-arbitrarily-inclined-leaves model coupled topography (GOSAILT) for sloping forest was proposed. The effects of slope, aspect, gravity field of tree crown, multiple scattering scheme, and diffuse skylight are considered. The area proportions of scene components estimated by the GOSAILT model were compared with the geometric optical model for sloping terrains (GOST) model. The 3-D discrete anisotropic radiative transfer (DART) simulations were used to evaluate the performance of GOSAILT. The results indicate that the canopy reflectance is distorted by the slopes with a maximum variation of 78.3% in the red band and 17.3% in the NIR band on a steep 60 º slope. Compared with the DART simulations, the proposed GOSAILT model can capture anisotropic reflectance well with a determine coefficient (R2) of 0.9720 and 0.6701, root-mean-square error (RMSE) of 0.0024 and 0.0393, mean absolute percentage error of 2.4% and 4.61% for the red and near-infrared (NIR) band. The comparison results indicate the GOSAIL model can accurately reproducing the angular feature of discrete canopy over rugged terrain conditions. The GOSAILT model is promising for the land surface biophysical parameters retrieval (e.g. albedo, leaf area index) over the heterogeneous terrain.

  5. Flow- topography Interactions in the Vicinity of a Deep Ocean Island and a Ridge

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Flow- topography Interactions in the Vicinity of a Deep...flow around abrupt topography in operational Navy models. RELATED PROJECTS NRL FY17 6.2 New Start proposal (pending proposal), titled...Predictability of Flow Interacting with Abrupt Topography (FIAT)”; lead PI: Ana Rice, NRL-SSC. The objective of FIAT is to use observations to develop Navy

  6. Detection of a dynamic topography signal in last interglacial sea-level records.

    Science.gov (United States)

    Austermann, Jacqueline; Mitrovica, Jerry X; Huybers, Peter; Rovere, Alessio

    2017-07-01

    Estimating minimum ice volume during the last interglacial based on local sea-level indicators requires that these indicators are corrected for processes that alter local sea level relative to the global average. Although glacial isostatic adjustment is generally accounted for, global scale dynamic changes in topography driven by convective mantle flow are generally not considered. We use numerical models of mantle flow to quantify vertical deflections caused by dynamic topography and compare predictions at passive margins to a globally distributed set of last interglacial sea-level markers. The deflections predicted as a result of dynamic topography are significantly correlated with marker elevations (>95% probability) and are consistent with construction and preservation attributes across marker types. We conclude that a dynamic topography signal is present in the elevation of last interglacial sea-level records and that the signal must be accounted for in any effort to determine peak global mean sea level during the last interglacial to within an accuracy of several meters.

  7. Coarsely resolved topography along protein folding pathways

    Science.gov (United States)

    Fernández, Ariel; Kostov, Konstantin S.; Berry, R. Stephen

    2000-03-01

    The kinetic data from the coarse representation of polypeptide torsional dynamics described in the preceding paper [Fernandez and Berry, J. Chem. Phys. 112, 5212 (2000), preceding paper] is inverted by using detailed balance to obtain a topographic description of the potential-energy surface (PES) along the dominant folding pathway of the bovine pancreatic trypsin inhibitor (BPTI). The topography is represented as a sequence of minima and effective saddle points. The dominant folding pathway displays an overall monotonic decrease in energy with a large number of staircaselike steps, a clear signature of a good structure-seeker. The diversity and availability of alternative folding pathways is analyzed in terms of the Shannon entropy σ(t) associated with the time-dependent probability distribution over the kinetic ensemble of contact patterns. Several stages in the folding process are evident. Initially misfolded states form and dismantle revealing no definite pattern in the topography and exhibiting high Shannon entropy. Passage down a sequence of staircase steps then leads to the formation of a nativelike intermediate, for which σ(t) is much lower and fairly constant. Finally, the structure of the intermediate is refined to produce the native state of BPTI. We also examine how different levels of tolerance to mismatches of side chain contacts influence the folding kinetics, the topography of the dominant folding pathway, and the Shannon entropy. This analysis yields upper and lower bounds of the frustration tolerance required for the expeditious and robust folding of BPTI.

  8. The updated geodetic mean dynamic topography model – DTU15MDT

    DEFF Research Database (Denmark)

    Knudsen, Per; Andersen, Ole Baltazar; Maximenko, Nikolai

    An update to the global mean dynamic topography model DTU13MDT is presented. For DTU15MDT the newer gravity model EIGEN-6C4 has been combined with the DTU15MSS mean sea surface model to construct this global mean dynamic topography model. The EIGEN-6C4 is derived using the full series of GOCE data...

  9. Development of a surface topography instrument for automotive textured steel plate

    Science.gov (United States)

    Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang

    2010-08-01

    The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.

  10. Qualification test of a MPPC-based PET module for future MRI-PET scanners

    Science.gov (United States)

    Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Funamoto, H.; Tsujikawa, T.; Yamamoto, S.

    2014-11-01

    We have developed a high-resolution, compact Positron Emission Tomography (PET) module for future use in MRI-PET scanners. The module consists of large-area, 4×4 ch MPPC arrays (Hamamatsu S11827-3344MG) optically coupled with Ce:LYSO scintillators fabricated into 12×12 matrices of 1×1 mm2 pixels. At this stage, a pair of module and coincidence circuits was assembled into an experimental prototype gantry arranged in a ring of 90 mm in diameter to form the MPPC-based PET system. The PET detector ring was then positioned around the RF coil of the 4.7 T MRI system. We took an image of a point 22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure interference between the MPPC-based PET and the MRI. We only found a slight degradation in the spatial resolution of the PET image from 1.63 to 1.70 mm (FWHM; x-direction), or 1.48-1.55 mm (FWHM; y-direction) when operating with the MRI, while the signal-to-noise ratio (SNR) of the MRI image was only degraded by 5%. These results encouraged us to develop a more advanced version of the MRI-PET gantry with eight MPPC-based PET modules, whose detailed design and first qualification test are also presented in this paper.

  11. Optical image modulation above the submarine bottom topography: a case study on the Taiwan Banks, China

    Science.gov (United States)

    Li, Yan; Hu, Jianyu; Li, Jing; Fu, Bin; Ma, Liming

    2003-05-01

    A possible mechanism to explain the correlation between submarine topography and the direct sunlight specially reflected from the sea surface with variable roughness caused by the bottom-current effect was suggested fifteen years ago by Henning et al. in International Journal of Remote Sensing, 9, 45-67, after comparing radar satellite image and Skylab satellite photograph of the North American east coast (Nantucket Shoals) with submarine relief features. A case study is carried out in the famous sand waves field located at the Taiwan banks of Taiwan Strait in August 1998. The TM images, either visible bands (TM1, TM2, TM3) or near infrared bands (TM4, TM5, TM7), shows submarine relief features for sand waves, with wavelength of 300 to 2000 meters, riding on the lager scale sand ridges and channel system. Sea truth data including 660 nm beam attenuation coefficient profiles were conducted in the same period. We compare signals of TM images, attenuation coefficient profiles, and sounding maps of the Taiwan Bands. The subsurface upwelling signals with contributions of the water column and the bottom, either estimated by single or quasi-single-scattering theory or revealed by the TM images after removing the contribution of direct sunlight reflected signals from sea surface, were too weak to distinguish the ridges and troughs of bedforms especially for red and near infrared bands. However, the direct sunlight specially reflected signals from the sea surface, approximately at same level in water-leaving reflectance not only for visible bands (TM1, TM2, TM3) but also for near infrared bands (TM4, TM5, TM7), was the major submarine bottom topography signals especially for those pixels towards the direction of the sun azimuth. Following a physical description for the lee waves appeared on free surface when the current flows round an underwater obstacle, the direct sunlight reflected signals related wave face slope, is dominated by the height and depth of sand waves and

  12. MRI assessment program. Consensus statement on clinical efficacy of MRI

    International Nuclear Information System (INIS)

    1998-05-01

    This consensus statement is largely based on the experience gained at the MRI units at the four hospitals which have operated scanners in the MRI program. It reflects the considered opinion of the radiologists responsible for the MRI services at those hospitals. Account has also been taken of relevant overseas data. This collection of opinion relates particularly to comparison with other imaging modalities. The specific comments will require further consideration as technical developments with MRI become available, additional experience is gained with gadolinium contrast material and additional data are obtained on the influence of MRI on patient management. MRI, at present, is used either to improve diagnostic accuracy when other tests are negative or equivocal, when there is strong clinical suspicion of disease, or to improve surgical or other management planning when the diagnosis known. In some situations (eg syringomyelia, congenital spinal disease, posterior fossa/cerebello-pontine angle tumours) it may entirely replace other tests (eg myelography, air contrast, CT) which are substantially less accurate and/or more invasive. In other situations (eg hemispheric brain tumours, lumbar disc protrusions) when other tests, such as CT, can be as accurate, MRI is not usually or initially indicated because it is currently more expensive and of limited availability. However, balanced against this is the fact that it does not expose the patient to potentially harmful ionising radiation. It is also stressed that MRI images depend on complex, widely variable and, as yet, incompletely understood parameters. There is concern that this may result in false positive diagnoses, especially where MRI is used alone as a screening test, or used as the initial test. For several reasons (availability, cost, medical and diagnostic efficacy), the specific comments on indications for MRI presented are based upon the assumption that MRI is a tertiary and complementary imaging examination

  13. A three-dimensional viscous topography mesoscale model

    Energy Technology Data Exchange (ETDEWEB)

    Eichhorn, J; Flender, M; Kandlbinder, T; Panhans, W G; Trautmann, T; Zdunkowski, W G [Mainz Univ. (Germany). Inst. fuer Physik der Atmosphaere; Cui, K; Ries, R; Siebert, J; Wedi, N

    1997-11-01

    This study describes the theoretical foundation and applications of a newly designed mesoscale model named CLIMM (climate model Mainz). In contrast to terrain following coordinates, a cartesian grid is used to keep the finite difference equations as simple as possible. The method of viscous topography is applied to the flow part of the model. Since the topography intersects the cartesian grid cells, the new concept of boundary weight factors is introduced for the solution of Poisson`s equation. A three-dimensional radiosity model was implemented to handle radiative transfer at the ground. The model is applied to study thermally induced circulations and gravity waves at an idealized mountain. Furthermore, CLIMM was used to simulate typical wind and temperature distributions for the city of Mainz and its rural surroundings. It was found that the model in all cases produced realistic results. (orig.) 38 refs.

  14. Characterization of surface topography and chemical composition of mini-implants

    OpenAIRE

    Knop, Luegya Amorim Henriques; Soares, Ana Prates; Shintcovsk, Ricardo Lima; Martins, Lidia Parsekian; Gandini Jr., Luiz Gonzaga

    2015-01-01

    Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis ...

  15. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...... been attained that markedly increase the number and typology of systems with CEST properties. Currently much attention is also devoted to hyperpolarized molecules that display a sensitivity enhancement sufficient for their direct exploitation for the formation of the MR image. A real breakthrough...

  16. The resolution sensitivity of the Asian summer monsoon and its inter-model comparison between MRI-AGCM and MetUM

    Science.gov (United States)

    Ogata, Tomomichi; Johnson, Stephanie J.; Schiemann, Reinhard; Demory, Marie-Estelle; Mizuta, Ryo; Yoshida, Kohei; Osamu Arakawa

    2017-11-01

    In this study, we compare the resolution sensitivity of the Asian Summer Monsoon (ASM) in two Atmospheric General Circulation Models (AGCMs): the MRI-AGCM and the MetUM. We analyze the MetUM at three different resolutions, N96 (approximately 200-km mesh on the equator), N216 (90-km mesh) and N512 (40-km mesh), and the MRI-AGCM at TL95 (approximately 180-km mesh on the equator), TL319 (60-km mesh), and TL959 (20-km mesh). The MRI-AGCM and the MetUM both show decreasing precipitation over the western Pacific with increasing resolution, but their precipitation responses differ over the Indian Ocean. In MRI-AGCM, a large precipitation increase appears off the equator (5-20°N). In MetUM, this off-equatorial precipitation increase is less significant and precipitation decreases over the equator. Moisture budget analysis demonstrates that a changing in moisture flux convergence at higher resolution is related to the precipitation response. Orographic effects, intra-seasonal variability and the representation of the meridional thermal gradient are explored as possible causes of the resolution sensitivity. Both high-resolution AGCMs (TL959 and N512) can represent steep topography, which anchors the rainfall pattern over south Asia and the Maritime Continent. In MRI-AGCM, representation of low pressure systems in TL959 also contributes to the rainfall pattern. Furthermore, the seasonal evolution of the meridional thermal gradient appears to be more accurate at higher resolution, particularly in the MRI-AGCM. These findings emphasize that the impact of resolution is only robust across the two AGCMs for some features of the ASM, and highlights the importance of multi-model studies of GCM resolution sensitivity.

  17. EAARL topography-Potato Creek watershed, Georgia, 2010

    Science.gov (United States)

    Bonisteel-Cormier, J.M.; Nayegandhi, Amar; Fredericks, Xan; Jones, J.W.; Wright, C.W.; Brock, J.C.; Nagle, D.B.

    2011-01-01

    This DVD contains lidar-derived first-surface (FS) and bare-earth (BE) topography GIS datasets of a portion of the Potato Creek watershed in the Apalachicola-Chattahoochee-Flint River basin, Georgia. These datasets were acquired on February 27, 2010.

  18. Optical Coherence Tomography and Magnetic Resonance Imaging in Multiple Sclerosis and Neuromyelitis Optica Spectrum Disorder.

    Science.gov (United States)

    Manogaran, Praveena; Hanson, James V M; Olbert, Elisabeth D; Egger, Christine; Wicki, Carla; Gerth-Kahlert, Christina; Landau, Klara; Schippling, Sven

    2016-11-15

    Irreversible disability in multiple sclerosis (MS) and neuromyelitis optica spectrum disorder (NMOSD) is largely attributed to neuronal and axonal degeneration, which, along with inflammation, is one of the major pathological hallmarks of these diseases. Optical coherence tomography (OCT) is a non-invasive imaging tool that has been used in MS, NMOSD, and other diseases to quantify damage to the retina, including the ganglion cells and their axons. The fact that these are the only unmyelinated axons within the central nervous system (CNS) renders the afferent visual pathway an ideal model for studying axonal and neuronal degeneration in neurodegenerative diseases. Structural magnetic resonance imaging (MRI) can be used to obtain anatomical information about the CNS and to quantify evolving pathology in MS and NMOSD, both globally and in specific regions of the visual pathway including the optic nerve, optic radiations and visual cortex. Therefore, correlations between brain or optic nerve abnormalities on MRI, and retinal pathology using OCT, may shed light on how damage to one part of the CNS can affect others. In addition, these imaging techniques can help identify important differences between MS and NMOSD such as disease-specific damage to the visual pathway, trans-synaptic degeneration, or pathological changes independent of the underlying disease process. This review focuses on the current knowledge of the role of the visual pathway using OCT and MRI in patients with MS and NMOSD. Emphasis is placed on studies that employ both MRI and OCT to investigate damage to the visual system in these diseases.

  19. The Relationship between Trail Running Withdrawals and Race Topography

    Directory of Open Access Journals (Sweden)

    Antonini Philippe Roberta

    2017-12-01

    Full Text Available Context: A growing amount of recent research in sport psychology has focused on trying to understand withdrawals from ultra-races. However, according to the Four E approach, the studies underestimated the embedded components of these experiences and particularly how they were linked to the specific environmental conditions in which the experiences occurred. Objective: This study aimed to characterize trail running withdrawals in relationship to race topography. Design: Qualitative design, involving self-confrontation interviews and use of a race map. Setting: Use of the race map for description of the race activity and self-confrontation interviews took place 1–3 days after the races. Participants: Ten runners who withdrew during an ultra-trail race. Data Collection and Analysis: Data on past activity traces and experiences were elicited from self-confrontation interviews. Data were coded and compared to identify common sequences and then each type of sequence was counted with regard to race topography. Results: Results showed that each sequence was related to runners’ particular possibilities for acting, feeling, and thinking, which were in turn embedded in the race topography. These sequences allowed the unfolding of the activity and increased its overall effectiveness in relation to the constraints of this specific sport. Conclusion: This study allowed us to highlight important information on how ultra-trail runners manage their races in relationship to the race environment and more specifically to its topography. The result will also help us to recommend potential adjustments to ultra-trail runners’ performance-oriented training and preparation.

  20. Bilateral optical nerve atrophy secondary to lateral occipital lobe infarction.

    Science.gov (United States)

    Mao, Junfeng; Wei, Shihui

    2013-06-01

    To report a phenomenon of optical nerve atrophy secondary to lateral occipital lobe infarction. Two successive patients with unilateral occipital lobe infarction who experienced bilateral optical nerve atrophy during the follow-up underwent cranial imaging, fundus photography, and campimetry. Each patient was diagnosed with occipital lobe infarction by cranial MRI. During the follow-up, a bilateral optic atrophy was revealed, and campimetry showed a right homonymous hemianopia of both eyes with concomitant macular division. Bilateral optic atrophy was related to occipital lobe infarction, and a possible explanation for the atrophy was transneuronal degeneration caused by occipital lobe infarction.

  1. An MRI-Conditional External Cardiac Defibrillator for Resuscitation Within the MRI Scanner Bore

    Science.gov (United States)

    Schmidt, Ehud J.; Watkins, Ronald D.; Zviman, Menekhem M.; Guttman, Michael A.; Wang, Wei; Halperin, Henry A.

    2016-01-01

    Background Subjects undergoing cardiac arrest within an MRI scanner are currently removed from the bore and then from the MRI suite, prior to delivery of CPR and defibrillation, potentially increasing risk of mortality. This precludes many higher-risk (acute-ischemic, acute-stroke) patients from undergoing MRI imaging and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the MRI seconds after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. Methods and Results A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by addition of novel Radio-Frequency (RF) filters between the generator and commercial disposable surface-pads. The RF filters reduced emission into the MRI scanner, and prevented cable/surface-pad heating during imaging, while preserving all the defibrillator’s monitoring and delivery functions. Human volunteers were imaged using high Specific-Absorption-Rate sequences to validate MRI image quality (IQ) and lack of heating. Swine were electrically fibrillated (N=4) and thereafter defibrillated both outside and inside the MRI bore. MRI IQ was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface-pads did not create artifacts deeper than 6mm below the skin surface. RF heating was within FDA guidelines. Defibrillation was completely successful inside and outside the MRI bore. Conclusions A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading image quality, or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. PMID:27729363

  2. Grooved surface topography alters matrix-metalloproteinase production by human fibroblasts

    Energy Technology Data Exchange (ETDEWEB)

    Brydone, Alistair S; Dominic Meek, R M [Department of Orthopaedics, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF (United Kingdom); Dalby, Matthew J; Berry, Catherine C; McNamara, Laura E, E-mail: alibrydone@gmail.com [Centre for Cell Engineering, Joseph Black Building, Institute of Molecular, Cell and Systems Biology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ (United Kingdom)

    2011-06-15

    Extracellular matrix (ECM) remodelling is an essential physiological process in which matrix-metalloproteinases (MMPs) have a key role. Manipulating the manner in which cells produce MMPs and ECMs may enable the creation of a desired tissue type, i.e. effect repair, or the prevention of tissue invasion (e.g. metastasis). The aim of this project was to determine if culturing fibroblasts on grooved topography altered collagen deposition or MMP production. Human fibroblasts were seeded on planar or grooved polycaprolactone substrates (grooves were 12.5 {mu}m wide with varying depths of 240 nm, 540 nm or 2300 nm). Cell behaviour and collagen production were studied using fluorescence microscopy and the spent culture medium was assessed using gel zymography to detect MMPs. Total collagen deposition was high on the 240 nm deep grooves, but decreased as the groove depth increased, i.e. as cell contact guidance decreased. There was an increase in gelatinase on the 2300 nm deep grooved topography and there was a difference in the temporal expression of MMP-3 observed on the planar surface compared to the 540 nm and 2300 nm topographies. These results show that topography can alter collagen and MMP production. A fuller understanding of these processes may permit the design of surfaces tailored to tissue regeneration e.g. tendon repair.

  3. Grooved surface topography alters matrix-metalloproteinase production by human fibroblasts

    International Nuclear Information System (INIS)

    Brydone, Alistair S; Dominic Meek, R M; Dalby, Matthew J; Berry, Catherine C; McNamara, Laura E

    2011-01-01

    Extracellular matrix (ECM) remodelling is an essential physiological process in which matrix-metalloproteinases (MMPs) have a key role. Manipulating the manner in which cells produce MMPs and ECMs may enable the creation of a desired tissue type, i.e. effect repair, or the prevention of tissue invasion (e.g. metastasis). The aim of this project was to determine if culturing fibroblasts on grooved topography altered collagen deposition or MMP production. Human fibroblasts were seeded on planar or grooved polycaprolactone substrates (grooves were 12.5 μm wide with varying depths of 240 nm, 540 nm or 2300 nm). Cell behaviour and collagen production were studied using fluorescence microscopy and the spent culture medium was assessed using gel zymography to detect MMPs. Total collagen deposition was high on the 240 nm deep grooves, but decreased as the groove depth increased, i.e. as cell contact guidance decreased. There was an increase in gelatinase on the 2300 nm deep grooved topography and there was a difference in the temporal expression of MMP-3 observed on the planar surface compared to the 540 nm and 2300 nm topographies. These results show that topography can alter collagen and MMP production. A fuller understanding of these processes may permit the design of surfaces tailored to tissue regeneration e.g. tendon repair.

  4. Altered Global Signal Topography in Schizophrenia.

    Science.gov (United States)

    Yang, Genevieve J; Murray, John D; Glasser, Matthew; Pearlson, Godfrey D; Krystal, John H; Schleifer, Charlie; Repovs, Grega; Anticevic, Alan

    2017-11-01

    Schizophrenia (SCZ) is a disabling neuropsychiatric disease associated with disruptions across distributed neural systems. Resting-state functional magnetic resonance imaging has identified extensive abnormalities in the blood-oxygen level-dependent signal in SCZ patients, including alterations in the average signal over the brain-i.e. the "global" signal (GS). It remains unknown, however, if these "global" alterations occur pervasively or follow a spatially preferential pattern. This study presents the first network-by-network quantification of GS topography in healthy subjects and SCZ patients. We observed a nonuniform GS contribution in healthy comparison subjects, whereby sensory areas exhibited the largest GS component. In SCZ patients, we identified preferential GS representation increases across association regions, while sensory regions showed preferential reductions. GS representation in sensory versus association cortices was strongly anti-correlated in healthy subjects. This anti-correlated relationship was markedly reduced in SCZ. Such shifts in GS topography may underlie profound alterations in neural information flow in SCZ, informing development of pharmacotherapies. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  5. Evaluation of shot peened surfaces using characterization technique of three-dimensional surface topography

    International Nuclear Information System (INIS)

    Kurokawa, S; Ariura, Y

    2005-01-01

    Objective parameters to characterize global topography of three-dimensional surfaces have been derived. The idea of this evaluation is to separate the topography into two global form deviations and residual ones according to the degree of curved surfaces. A shot peened Almen strip is measured by profilometer and concrete parameters of inclination and circular-arc shaped global topography are extracted using the characterization technique. The arc height is calculated using the circular arc-shaped part and compared with a value measured by an Almen gauge. The relation between the coverage and roughness parameters is also investigated. The advantage of this evaluation is that it is possible to determine the arc height and the coverage at the same time from single measured topography. In addition, human error can be excluded from measurement results. This method has the wide application in the field of measurement

  6. Venus gravity and topography: 60th degree and order model

    Science.gov (United States)

    Konopliv, A. S.; Borderies, N. J.; Chodas, P. W.; Christensen, E. J.; Sjogren, W. L.; Williams, B. G.; Balmino, G.; Barriot, J. P.

    1993-01-01

    We have combined the most recent Pioneer Venus Orbiter (PVO) and Magellan (MGN) data with the earlier 1978-1982 PVO data set to obtain a new 60th degree and order spherical harmonic gravity model and a 120th degree and order spherical harmonic topography model. Free-air gravity maps are shown over regions where the most marked improvement has been obtained (Ishtar-Terra, Alpha, Bell and Artemis). Gravity versus topography relationships are presented as correlations per degree and axes orientation.

  7. Crater topography on Titan: Implications for landscape evolution

    Science.gov (United States)

    Neish, C.; Kirk, R.; Lorenz, R.; Bray, V.; Schenk, P.; Stiles, B.; Turtle, E.; Cassini Radar Team

    2012-04-01

    Unique among the icy satellites, Titan’s surface shows evidence for extensive modification by fluvial and aeolian erosion, which act to change the topography of its surface over time. Quantifying the extent of this landscape evolution is difficult, since the original, ‘non-eroded’ surface topography is generally unknown. However, fresh craters on icy satellites have a well-known shape and morphology, which has been determined from extensive studies on the airless worlds of the outer solar system (Schenk et al., 2004). By comparing the topography of craters on Titan to similarly sized, pristine analogues on airless bodies, we can obtain one of the few direct measures of the amount of erosion that has occurred on Titan. Cassini RADAR has imaged >30% of the surface of Titan, and more than 60 potential craters have been identified in this data set (Wood et al., 2010; Neish and Lorenz, 2012). Topographic information for these craters can be obtained from a technique known as ‘SARTopo’, which estimates surface heights by comparing the calibration of overlapping synthetic aperture radar (SAR) beams (Stiles et al., 2009). We present topography data for several craters on Titan, and compare the data to similarly sized craters on Ganymede, for which topography has been extracted from stereo-derived digital elevation models (Bray et al., 2012). We find that the depths of craters on Titan are generally within the range of depths observed on Ganymede, but several hundreds of meters shallower than the average (Fig. 1). A statistical comparison between the two data sets suggests that it is extremely unlikely that Titan’s craters were selected from the depth distribution of fresh craters on Ganymede, and that is it much more probable that the relative depths of Titan are uniformly distributed between ‘fresh’ and ‘completely infilled’. This is consistent with an infilling process that varies linearly with time, such as aeolian infilling. Figure 1: Depth of

  8. Integrated microchip incorporating atomic magnetometer and microfluidic channel for NMR and MRI

    Science.gov (United States)

    Ledbetter, Micah P [Oakland, CA; Savukov, Igor M [Los Alamos, NM; Budker, Dmitry [El Cerrito, CA; Shah, Vishal K [Plainsboro, NJ; Knappe, Svenja [Boulder, CO; Kitching, John [Boulder, CO; Michalak, David J [Berkeley, CA; Xu, Shoujun [Houston, TX; Pines, Alexander [Berkeley, CA

    2011-08-09

    An integral microfluidic device includes an alkali vapor cell and microfluidic channel, which can be used to detect magnetism for nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Small magnetic fields in the vicinity of the vapor cell can be measured by optically polarizing and probing the spin precession in the small magnetic field. This can then be used to detect the magnetic field of in encoded analyte in the adjacent microfluidic channel. The magnetism in the microfluidic channel can be modulated by applying an appropriate series of radio or audio frequency pulses upstream from the microfluidic chip (the remote detection modality) to yield a sensitive means of detecting NMR and MRI.

  9. Assessment of refractive astigmatism and simulated therapeutic refractive surgery strategies in coma-like-aberrations-dominant corneal optics.

    Science.gov (United States)

    Zhou, Wen; Stojanovic, Aleksandar; Utheim, Tor Paaske

    2016-01-01

    The aim of the study is to raise the awareness of the influence of coma-like higher-order aberrations (HOAs) on power and orientation of refractive astigmatism (RA) and to explore how to account for that influence in the planning of topography-guided refractive surgery in eyes with coma-like-aberrations-dominant corneal optics. Eleven eyes with coma-like-aberrations-dominant corneal optics and with low lenticular astigmatism (LA) were selected for astigmatism analysis and for treatment simulations with topography-guided custom ablation. Vector analysis was used to evaluate the contribution of coma-like corneal HOAs to RA. Two different strategies were used for simulated treatments aiming to regularize irregular corneal optics: With both strategies correction of anterior corneal surface irregularities (corneal HOAs) were intended. Correction of total corneal astigmatism (TCA) and RA was intended as well with strategies 1 and 2, respectively. Axis of discrepant astigmatism (RA minus TCA minus LA) correlated strongly with axis of coma. Vertical coma influenced RA by canceling the effect of the with-the-rule astigmatism and increasing the effect of the against-the-rule astigmatism. After simulated correction of anterior corneal HOAs along with TCA and RA (strategies 1 and 2), only a small amount of anterior corneal astigmatism (ACA) and no TCA remained after strategy 1, while considerable amount of ACA and TCA remained after strategy 2. Coma-like corneal aberrations seem to contribute a considerable astigmatic component to RA in eyes with coma-like-aberrations dominant corneal optics. If topography-guided ablation is programmed to correct the corneal HOAs and RA, the astigmatic component caused by the coma-like corneal HOAs will be treated twice and will result in induced astigmatism. Disregarding RA and treating TCA along with the corneal HOAs is recommended instead.

  10. Monitoring local heating around an interventional MRI antenna with RF radiometry

    Energy Technology Data Exchange (ETDEWEB)

    Ertürk, M. Arcan [Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland 21287 and Division of MR Research, Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, Maryland 21287 (United States); El-Sharkawy, AbdEl-Monem M.; Bottomley, Paul A., E-mail: bottoml@mri.jhu.edu [Division of MR Research, Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, Maryland 21287 (United States)

    2015-03-15

    Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or

  11. Monitoring local heating around an interventional MRI antenna with RF radiometry

    Science.gov (United States)

    Ertürk, M. Arcan; El-Sharkawy, AbdEl-Monem M.; Bottomley, Paul A.

    2015-01-01

    Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or

  12. Monitoring local heating around an interventional MRI antenna with RF radiometry

    International Nuclear Information System (INIS)

    Ertürk, M. Arcan; El-Sharkawy, AbdEl-Monem M.; Bottomley, Paul A.

    2015-01-01

    Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or

  13. Topography on Titan : New Results on Large and Small Scales

    Science.gov (United States)

    Lorenz, R. D.; Cassini Radar Team

    2011-12-01

    Although topographic coverage of Titan is and will remain sparse, some significant results have been obtained from global, regional and local measurements, via stereo, radarclinometry (shape-from-shading), autostereo (deviation from an assumed symmetric shape due to the inclined incidence), altimetry and SARtopo (monopulse) techniques. The global ellipsoidal shape (Zebker et al., 2009) provides important geophysical constraints on the interior. Hypsometry (Lorenz et al., 2011) provides insight into the balance of constructional and erosive processes and the strength of the lithosphere. Some local observations to be summarized in the talk include the measurement of mountains, the quantification of slopes that divert dunes and that drive fluid flow in river networks, as well as depth measurement of several impact craters and the assessment of candidate cryovolcanic structures. A recent new observation is a long altimetry pass T77 along the equator at the western edge of Xanadu, acquired both to constrain Titan's global shape and to understand the surface slopes and properties that may maintain the striking contrast between the dune fields of Shangri-La and the rugged and radiometrically anomalous Xanadu region. T77 also featured a SAR observation of the Ksa impact structure (discovered in SAR on T17), allowing a stereo DEM to be constructed. A feature shared by Earth and Titan is the ephemeral topography of liquids on the surface. Titan's lakes and seas likely vary in depth on geological (Myr-Gyr) and astronomical (~10 kyr) timescales : the depth of Ontario Lacus has been observed to vary on a seasonal timescale (~1 m/yr). Periodic changes of the order of 0.2-5m may occur diurnally, forced by Saturn gravitational tides. Finally, waves may be generated, at least during the windy season (which for Titan's north may be just about to begin) which can be constrained by radar and optical scattering measurements. Looking to the future, a Phase A study of the Titan Mare

  14. Airborne Instrument Simulator for the Lidar Surface Topography (LIST) Mission

    Science.gov (United States)

    Yu, Anthony W.; Krainak, Michael A.; Harding, David J.; Abshire, James B.; Sun, Xiaoli; Cavanaugh, John; Valett, Susan; Ramos-Izquierdo, Luis

    2010-01-01

    In 2007, the National Research Council (NRC) completed its first decadal survey for Earth science at the request of NASA, NOAA, and USGS. The Lidar Surface Topography (LIST) mission is one of fifteen missions recommended by NRC, whose primary objectives are to map global topography and vegetation structure at 5 m spatial resolution, and to acquire global coverage with a few years. NASA Goddard conducted an initial mission concept study for the LIST mission 2007, and developed the initial measurement requirements for the mission.

  15. Airborne Lidar Simulator for the Lidar Surface Topography (LIST) Mission

    Science.gov (United States)

    Yu, Anthony W.; Krainak, Michael A.; Abshire, James B.; Cavanaugh, John; Valett, Susan; Ramos-Izquierdo, Luis

    2010-01-01

    In 2007, the National Research Council (NRC) completed its first decadal survey for Earth science at the request of NASA, NOAA, and USGS. The Lidar Surface Topography (LIST) mission is one of fifteen missions recommended by NRC, whose primary objectives are to map global topography and vegetation structure at 5 m spatial resolution, and to acquire global surface height mapping within a few years. NASA Goddard conducted an initial mission concept study for the LIST mission in 2007, and developed the initial measurement requirements for the mission.

  16. Integrated Surface Topography Characterization of Variously Polished Niobium for Superconducting Particle Accelerators

    International Nuclear Information System (INIS)

    Tian, Hui; Reece, Charles; Kelley, Michael; Ribeill, G.

    2009-01-01

    As superconducting niobium radio-frequency (SRF) cavities approach fundamental material limits, there is increased interest in understanding the details of topographical influences on realized performance limitations. Micro-and nano-roughness are implicated in both direct geometrical field enhancements as well as complications of the composition of the 50 nm surface layer in which the super-currents flow. Interior surface chemical polishing (BCP/EP) to remove mechanical damage leaves surface topography, including pits and protrusions of varying sharpness. These may promote RF magnetic field entry, locally quenching superconductivity, so as to degrade cavity performance. A more incisive analysis of surface topography than the widely-used average roughness is needed. In this study, a power spectral density (PSD) approach based on Fourier analysis of surface topography data acquired by both stylus profilometry and atomic force microscopy (AFM) is being used to distinguish the scale-dependent smoothing effects. The topographical evolution of the Nb surface as a function of different steps of EP is reported, resulting in a novel qualitative and quantitative description of Nb surface topography.

  17. Analysis of task-evoked systemic interference in fNIRS measurements: insights from fMRI.

    Science.gov (United States)

    Erdoğan, Sinem B; Yücel, Meryem A; Akın, Ata

    2014-02-15

    Functional near infrared spectroscopy (fNIRS) is a promising method for monitoring cerebral hemodynamics with a wide range of clinical applications. fNIRS signals are contaminated with systemic physiological interferences from both the brain and superficial tissues, resulting in a poor estimation of the task related neuronal activation. In this study, we use the anatomical resolution of functional magnetic resonance imaging (fMRI) to extract scalp and brain vascular signals separately and construct an optically weighted spatial average of the fMRI blood oxygen level-dependent (BOLD) signal for characterizing the scalp signal contribution to fNIRS measurements. We introduce an extended superficial signal regression (ESSR) method for canceling physiology-based systemic interference where the effects of cerebral and superficial systemic interference are treated separately. We apply and validate our method on the optically weighted BOLD signals, which are obtained by projecting the fMRI image onto optical measurement space by use of the optical forward problem. The performance of ESSR method in removing physiological artifacts is compared to i) a global signal regression (GSR) method and ii) a superficial signal regression (SSR) method. The retrieved signals from each method are compared with the neural signals that represent the 'ground truth' brain activation cleaned from cerebral systemic fluctuations. We report significant improvements in the recovery of task induced neural activation with the ESSR method when compared to the other two methods as reflected in the Pearson R(2) coefficient and mean square error (MSE) metrics (two tailed paired t-tests, pnoise (CNR) improvement (60%). Our findings suggest that, during a cognitive task i) superficial scalp signal contribution to fNIRS signals varies significantly among different regions on the forehead and ii) using an average scalp measurement together with a local measure of superficial hemodynamics better accounts

  18. Outcomes of photorefractive keratectomy in patients with atypical topography.

    Science.gov (United States)

    Movahedan, Hossein; Namvar, Ehsan; Farvardin, Mohsen

    2017-11-01

    Photorefractive keratectomy (PRK) is at risk of serious complications such as corneal ectasia, which can reduce corrected distance visual acuity. The rate of complications of PRK is higher in patients with atypical topography. To determine the outcomes of photorefractive keratectomy in patients with atypical topography. This cross-sectional study was done in 2015 in Shiraz in Iran. We included 85 eyes in this study. The samples were selected using a simple random sampling method. All patients were under evaluation for uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction, corneal topography, central corneal thickness using pentacam, slit-lamp microscopy, and detailed fondus evaluation. The postoperative examination was done 1-7 years after surgery. Data were analyzed using IBM SPSS 21.0 version. To analyze the data, descriptive statistics (frequency, percentage, mean, and standard deviation), chi-square, and independent samples t-test were used. We studied 85 eyes. Among the patients, 23 (27.1%) were male and 62 (72.9%) were female. Mean age of the participants was 28.25±5.55 years. Mean postoperative refraction was - 0.37±0.55 diopters. Keratoconus or corneal ectasia was not reported in any patient in this study. There was no statistically significant difference between SI index before and after operation (p=0.736). Mean preoperative refraction was -3.84 ± 1.46 diopters in males and -4.20±1.96 diopters in females; thus there was not statistically significant difference (p = 0.435). PRK is a safe and efficient photorefractive surgery and is associated with low complication rate in patients with atypical topography.

  19. Roles of Fog and Topography in Redwood Forest Hydrology

    Science.gov (United States)

    Francis, E. J.; Asner, G. P.

    2017-12-01

    Spatial variability of water in forests is a function of both climatic gradients that control water inputs and topo-edaphic variation that determines the flows of water belowground, as well as interactions of climate with topography. Coastal redwood forests are hydrologically unique because they are influenced by coastal low clouds, or fog, that is advected onto land by a strong coastal-to-inland temperature difference. Where fog intersects the land surface, annual water inputs from summer fog drip can be greater than that of winter rainfall. In this study, we take advantage of mapped spatial gradients in forest canopy water storage, topography, and fog cover in California to better understand the roles and interactions of fog and topography in the hydrology of redwood forests. We test a conceptual model of redwood forest hydrology with measurements of canopy water content derived from high-resolution airborne imaging spectroscopy, topographic variables derived from high-resolution LiDAR data, and fog cover maps derived from NASA MODIS data. Landscape-level results provide insight into hydrological processes within redwood forests, and cross-site analyses shed light on their generality.

  20. Week Long Topography Study of Young Adults Using Electronic Cigarettes in Their Natural Environment.

    Science.gov (United States)

    Robinson, R J; Hensel, E C; Roundtree, K A; Difrancesco, A G; Nonnemaker, J M; Lee, Y O

    2016-01-01

    Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol) are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment.

  1. Week Long Topography Study of Young Adults Using Electronic Cigarettes in Their Natural Environment.

    Directory of Open Access Journals (Sweden)

    R J Robinson

    Full Text Available Results of an observational, descriptive study quantifying topography characteristics of twenty first generation electronic nicotine delivery system users in their natural environment for a one week observation period are presented. The study quantifies inter-participant variation in puffing topography between users and the intra-participant variation for each user observed during one week of use in their natural environment. Puff topography characteristics presented for each user include mean puff duration, flow rate and volume for each participant, along with descriptive statistics of each quantity. Exposure characteristics including the number of vaping sessions, total number of puffs and cumulative volume of aerosol generated from ENDS use (e-liquid aerosol are reported for each participant for a one week exposure period and an effective daily average exposure. Significant inter-participant and intra-participant variation in puff topography was observed. The observed range of natural use environment characteristics is used to propose a set of topography protocols for use as command inputs to drive machine-puffed electronic nicotine delivery systems in a controlled laboratory environment.

  2. Hydraulic experiment on flow and topography change in harbor due to tsunami and its numerical simulation

    International Nuclear Information System (INIS)

    Fujii, Naoki; Ikeno, Masaaki; Sakakiyama, Tsutomu; Matsuyama, Masafumi; Takao, Makoto; Mukohara, Takeshi

    2009-01-01

    Numerical model of topography change is important to examine collapse of the harbor facilities by sand transport due to tsunami. Problems for evaluation of sand transport due to tsunami with topography change model are in precision of the numerical model and topography change data. Therefore, we installed the harbor in large-scaled wave tank and carried out experiment about tsunami flow and topography change to get those detailed data. For results provided by experimental test, we applied the topography change model of Ikeno et al. (2009a) and evaluated it about the reproduction characteristics. As a result, it was confirmed that reproduction of an experiment improved by using new pickup rate formula proposed by Ikeno et al. (2009a). (author)

  3. Risk assessment and driving factors for artificial topography on element heterogeneity: Case study at Jiangsu, China.

    Science.gov (United States)

    Hong, Hualong; Dai, Minyue; Lu, Haoliang; Liu, Jingchun; Zhang, Jie; Yan, Chongling

    2018-02-01

    The rapid expansion of construction related to coastal development evokes great concern about environmental risks. Recent attention has been focused mainly on factors related to the effects of waterlogging, but there is urgent need to address the potential hazard caused by artificial topography: derived changes in the elemental composition of the sediments. To reveal possible mechanisms and to assess the environmental risks of artificial topography on transition of elemental composition in the sediment at adjoining zones, a nest-random effects-combined investigation was carried out around a semi-open seawall. The results implied great changes induced by artificial topography. Not only did artificial topography alter the sediment elemental composition at sites under the effect of artificial topography, but also caused a coupling pattern transition of elements S and Cd. The biogeochemical processes associated with S were also important, as suggested by cluster analysis. The geo-accumulation index shows that artificial topography triggered the accumulation of C, N, S, Cu, Fe, Mn, Zn, Ni, Cr, Pb, As and Cd, and increased the pollution risk of C, N, S, Cu, As and Cd. Enrichment factors reveal that artificial topography is a new type of human-activity-derived Cu contamination. The heavy metal Cu was notably promoted on both the geo-accumulation index and the enrichment factor under the influence of artificial topography. Further analysis showed that the Cu content in the sediment could be fitted using equations for Al and organic carbon, which represented clay mineral sedimentation and organic matter accumulation, respectively. Copper could be a reliable indicator of environmental degradation caused by artificial topography. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. MRI estimation of extraocular muscle swelling in dysthyroid ophthalmopathy

    International Nuclear Information System (INIS)

    Watanabe, Yoshihiro; Kakisu, Yonetsugu; Hatakeyama, Masayuki; Asanagi, Kaoru

    1988-01-01

    The thickness and width of superior, inferior and medial rectus muscles were measured via T1-weighted coronal images using a 0.5 T superconducting MRI (magnetic resonance imaging) system in 10 patients with dysthyroid ophthalmopathy and 27 normal orbits. Lateral rectus muscles were not measured because the partial volume effect obscured their contours. Patients were divided into 3 groups according to the severity of ophthalmopathy. Group A had no ophthalmopathy, group B had corneal involvement or restricted eye movement, group C had optic nerve involvement. Mean muscle thickness increased in the order A, B and C. Mean rectus muscle width was normal in group A, but dramatically increased in group C, results suggesting that swelling of the extraocular muscles is a characteristic pathologic change in dysthyroid ophthalmopathy. It is concluded that MRI is a safe and useful method of evaluating the severity of and prognosing dysthyroid ophthalmopathy. (author)

  5. Power laws for gravity and topography of Solar System bodies

    Science.gov (United States)

    Ermakov, A.; Park, R. S.; Bills, B. G.

    2017-12-01

    When a spacecraft visits a planetary body, it is useful to be able to predict its gravitational and topographic properties. This knowledge is important for determining the level of perturbations in spacecraft's motion as well as for planning the observation campaign. It has been known for the Earth that the power spectrum of gravity follows a power law, also known as the Kaula rule (Kaula, 1963; Rapp, 1989). A similar rule was derived for topography (Vening-Meinesz, 1951). The goal of this paper is to generalize the power law that can characterize the gravity and topography power spectra for bodies across a wide range of size. We have analyzed shape power spectra of the bodies that have either global shape and gravity field measured. These bodies span across five orders of magnitude in their radii and surface gravities and include terrestrial planets, icy moons and minor bodies. We have found that despite having different internal structure, composition and mechanical properties, the topography power spectrum of these bodies' shapes can be modeled with a similar power law rescaled by the surface gravity. Having empirically found a power law for topography, we can map it to a gravity power law. Special care should be taken for low-degree harmonic coefficients due to potential isostatic compensation. For minor bodies, uniform density can be assumed. The gravity coefficients are a linear function of the shape coefficients for close-to-spherical bodoes. In this case, the power law for gravity will be steeper than the power law of topography due to the factor (2n+1) in the gravity expansion (e.g. Eq. 10 in Wieczorek & Phillips, 1998). Higher powers of topography must be retained for irregularly shaped bodies, which breaks the linearity. Therefore, we propose the following procedure to derive an a priori constraint for gravity. First, a surface gravity needs to be determined assuming typical density for the relevant class of bodies. Second, the scaling coefficient of the

  6. Effects of titanium surface topography on bone integration: a systematic review.

    Science.gov (United States)

    Wennerberg, Ann; Albrektsson, Tomas

    2009-09-01

    To analyse possible effects of titanium surface topography on bone integration. Our analyses were centred on a PubMed search that identified 1184 publications of assumed relevance; of those, 1064 had to be disregarded because they did not accurately present in vivo data on bone response to surface topography. The remaining 120 papers were read and analysed, after removal of an additional 20 papers that mainly dealt with CaP-coated and Zr implants; 100 papers remained and formed the basis for this paper. The bone response to differently configurated surfaces was mainly evaluated by histomorphometry (bone-to-implant contact), removal torque and pushout/pullout tests. A huge number of the experimental investigations have demonstrated that the bone response was influenced by the implant surface topography; smooth (S(a)1-2 microm) surfaces showed stronger bone responses than rough (S(a)>2 microm) in some studies. One limitation was that it was difficult to compare many studies because of the varying quality of surface evaluations; a surface termed 'rough' in one study was not uncommonly referred to as 'smooth' in another; many investigators falsely assumed that surface preparation per se identified the roughness of the implant; and many other studies used only qualitative techniques such as SEM. Furthermore, filtering techniques differed or only height parameters (S(a), R(a)) were reported. * Surface topography influences bone response at the micrometre level. * Some indications exist that surface topography influences bone response at the nanometre level. * The majority of published papers present an inadequate surface characterization. * Measurement and evaluation techniques need to be standardized. * Not only height descriptive parameters but also spatial and hybrid ones should be used.

  7. Postoperative follow-up of pituitary adenomas after trans-sphenoidal resection: MRI and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, O. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Mateos, B. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pedraja, R. de la [Servicio de Endocrinologia, Hospital de Cruces, Baracaldo (Spain); Villoria, R. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Hernando, J.I. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pastor, A. [Servicio de Radiologia, Hospital de Cruces, Baracaldo (Spain); Pomposo, I. [Servicio de Neurocirugia, Hospital de Cruces, Baracaldo (Spain); Aurrecoechea, J. [Servicio de Neurocirugia, Hospital de Cruces, Baracaldo (Spain)

    1996-11-01

    Our purpose was to correlate the morphological changes seen on MRI studies of the sellar region after trans-sphenoidal resection of pituitary adenomas with clinical and hormonal studies. Between January 1993 and March 1994, 16 patients with a pituitary adenoma (9 macroadenomas and 7 microadenomas) were subjected to trans-sphenoidal resection and included in a prospective study. The protocol consisted of MRI, hormonal and visual studies at the following times: immediately postoperative (1st week), 1st month, 4th month and 1st year after surgery. The evolution of the contents of the sella turcica (tumour remnant, packing material and gland tissue), effects on the infundibulum, optic chiasm, cavernous sinus and sphenoid sinus were correlated with the clinical and hormonal studies. Stabilisation of the postsurgical changes occurred by the 4th month. Tumour remnants were noted in the immediate postoperative period in macroadenomas. Compression of the infundibulum was the only reliable indicator of possible involvement. Optic chiasm compression, defined as close contact between the chiasm and the tumour, was the only morphological finding that indicated visual impairment. There was no standard repneumatisation pattern in the sphenoid sinus, since mucosal changes resembling sinusitis were one of the postsurgical changes. We found MRI not to be useful for follow-up of microadenomas. (orig.). With 4 figs., 4 tabs.

  8. Postoperative follow-up of pituitary adenomas after trans-sphenoidal resection: MRI and clinical correlation

    International Nuclear Information System (INIS)

    Rodriguez, O.; Mateos, B.; Pedraja, R. de la; Villoria, R.; Hernando, J.I.; Pastor, A.; Pomposo, I.; Aurrecoechea, J.

    1996-01-01

    Our purpose was to correlate the morphological changes seen on MRI studies of the sellar region after trans-sphenoidal resection of pituitary adenomas with clinical and hormonal studies. Between January 1993 and March 1994, 16 patients with a pituitary adenoma (9 macroadenomas and 7 microadenomas) were subjected to trans-sphenoidal resection and included in a prospective study. The protocol consisted of MRI, hormonal and visual studies at the following times: immediately postoperative (1st week), 1st month, 4th month and 1st year after surgery. The evolution of the contents of the sella turcica (tumour remnant, packing material and gland tissue), effects on the infundibulum, optic chiasm, cavernous sinus and sphenoid sinus were correlated with the clinical and hormonal studies. Stabilisation of the postsurgical changes occurred by the 4th month. Tumour remnants were noted in the immediate postoperative period in macroadenomas. Compression of the infundibulum was the only reliable indicator of possible involvement. Optic chiasm compression, defined as close contact between the chiasm and the tumour, was the only morphological finding that indicated visual impairment. There was no standard repneumatisation pattern in the sphenoid sinus, since mucosal changes resembling sinusitis were one of the postsurgical changes. We found MRI not to be useful for follow-up of microadenomas. (orig.). With 4 figs., 4 tabs

  9. Surface topography of hydroxyapatite promotes osteogenic differentiation of human bone marrow mesenchymal stem cells.

    Science.gov (United States)

    Yang, Wanlei; Han, Weiqi; He, Wei; Li, Jianlei; Wang, Jirong; Feng, Haotian; Qian, Yu

    2016-03-01

    Effective and safe induction of osteogenic differentiation is one of the key elements of bone tissue engineering. Surface topography of scaffold materials was recently found to promote osteogenic differentiation. Utilization of this topography may be a safer approach than traditional induction by growth factors or chemicals. The aim of this study is to investigate the enhancement of osteogenic differentiation by surface topography and its mechanism of action. Hydroxyapatite (HA) discs with average roughness (Ra) of surface topography ranging from 0.2 to 1.65 μm and mean distance between peaks (RSm) ranging from 89.7 to 18.6 μm were prepared, and human bone-marrow mesenchymal stem cells (hBMSCs) were cultured on these discs. Optimal osteogenic differentiation was observed on discs with surface topography characterized by Ra ranging from 0.77 to 1.09 μm and RSm ranging from 53.9 to 39.3 μm. On this surface configuration of HA, hBMSCs showed oriented attachment, F-actin arrangement, and a peak in the expression of Yes-associated protein (YAP) and PDZ binding motif (TAZ) (YAP/TAZ). These results indicated that the surface topography of HA promoted osteogenic differentiation of hBMSCs, possibly by increasing cell attachment and promoting the YAP/TAZ signaling pathway. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Topography of sensory symptoms in patients with drug-naïve restless legs syndrome.

    Science.gov (United States)

    Koo, Yong Seo; Lee, Gwan-Taek; Lee, Seo Young; Cho, Yong Won; Jung, Ki-Young

    2013-12-01

    We aimed to describe the sensory topography of restless legs syndrome (RLS) sensory symptoms and to identify the relationship between topography and clinical variables. Eighty adult patients with drug-naïve RLS who had symptoms for more than 1year were consecutively recruited. During face-to-face interviews using a structured paper and pencil questionnaire with all participants, we obtained clinical information and also marked the topography of RLS sensory symptoms on a specified body template, all of which were subsequently inputted into our in-house software. The RLS sensory topography patterns were classified according to localization, lateralization, and symmetry. We investigated if these sensory topography patterns differed according to various clinical variables. The lower extremities only (LE) were the most common location (72.5%), and 76.3% of participants exhibited symmetric sensory topography. Late-onset RLS showed more asymmetric sensory distribution compared with early-onset RLS (P=.024). Patients whose sensory symptoms involved the lower extremities in addition to other body parts (LE-PLUS) showed more severe RLS compared with those involving the LE (P=.037). RLS sensory symptoms typically were symmetrically located in the lower extremities. LE-PLUS or an asymmetric distribution more often occurred in patients with more severe RLS symptoms or late-onset RLS. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Comparison of static MRI and pseudo-dynamic MRI in temporomandibular joint disorder patients

    International Nuclear Information System (INIS)

    Lee, Jin Ho; Yun, Kyoung In; Park, In Woo; Choi, Hang Moon; Park, Moon Soo

    2006-01-01

    The purpose of this study was to elevate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P>0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change

  12. Comparison of static MRI and pseudo-dynamic MRI in temporomandibular joint disorder patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Ho; Yun, Kyoung In [Eulji Univ. School of Medicine, Seoul (Korea, Republic of); Park, In Woo; Choi, Hang Moon; Park, Moon Soo [Kangnung National Univ. College of Dentistry, Kangnung (Korea, Republic of)

    2006-12-15

    The purpose of this study was to elevate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P>0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  13. Simultaneous topography imaging and broadband nanomechanical mapping on atomic force microscope

    Science.gov (United States)

    Li, Tianwei; Zou, Qingze

    2017-12-01

    In this paper, an approach is proposed to achieve simultaneous imaging and broadband nanomechanical mapping of soft materials in air by using an atomic force microscope. Simultaneous imaging and nanomechanical mapping are needed, for example, to correlate the morphological and mechanical evolutions of the sample during dynamic phenomena such as the cell endocytosis process. Current techniques for nanomechanical mapping, however, are only capable of capturing static elasticity of the material, or the material viscoelasticity in a narrow frequency band around the resonant frequency(ies) of the cantilever used, not competent for broadband nanomechanical mapping, nor acquiring topography image of the sample simultaneously. These limitations are addressed in this work by enabling the augmentation of an excitation force stimuli of rich frequency spectrum for nanomechanical mapping in the imaging process. Kalman-filtering technique is exploited to decouple and split the mixed signals for imaging and mapping, respectively. Then the sample indentation generated is quantified online via a system-inversion method, and the effects of the indentation generated and the topography tracking error on the topography quantification are taken into account. Moreover, a data-driven feedforward-feedback control is utilized to track the sample topography. The proposed approach is illustrated through experimental implementation on a polydimethylsiloxane sample with a pre-fabricated pattern.

  14. Nano-topography Enhances Communication in Neural Cells Networks

    KAUST Repository

    Onesto, V.; Cancedda, L.; Coluccio, M. L.; Nanni, M.; Pesce, M.; Malara, N.; Cesarelli, M.; Di Fabrizio, Enzo M.; Amato, F.; Gentile, F.

    2017-01-01

    Neural cells are the smallest building blocks of the central and peripheral nervous systems. Information in neural networks and cell-substrate interactions have been heretofore studied separately. Understanding whether surface nano-topography can

  15. School scoliosis screening by Moiré topography - Overview for 33 years in Miyazaki Japan.

    Science.gov (United States)

    Kuroki, Hiroshi; Nagai, Takuya; Chosa, Etsuo; Tajima, Naoya

    2018-04-05

    Since 1981, we have performed school scoliosis screening (SSS) using Moiré topography in Miyazaki, Japan and attained a certain result in detecting scoliosis. However, this screening system was discontinued due to cessation of repair and production of Moiré topographic equipment. The purpose of this study was to make clear both the results and the problems of SSS by Moiré topography on the basis of our past 33 years' experiences. The subjects were 689,293 students (5th grade boys in 200,329, 5th grade girls in 191,919, 8th grade boys in 151,351, and 8th grade girls in 145,694) who were screened by Moiré topography between 1981 and 2013. The number of students received SSS, the positive rate of Moiré topography, the discovery rate of scoliosis greater than 20°, the reference rate to the second screening, and the positive predictive value of Moiré topography to detect scoliosis greater than 20° were investigated. The number of students received SSS achieved a peak in 1992. The positive rate of Moiré topography and the discovery rate of scoliosis were highest in 8th grade girls. The reference rates to the second screening were 49.8% in 5th grade students and 41.4% in 8th grade students. The positive predictive values were 2.1% in 5th grade students and 7.6% in 8th grade students. SSS by Moiré topography seemed to be effective in detecting scoliosis although both the positive predictive value and the reference rate to the second screening were low. Copyright © 2018. Published by Elsevier B.V.

  16. A consistent data set of Antarctic ice sheet topography, cavity geometry, and global bathymetry

    Directory of Open Access Journals (Sweden)

    R. Timmermann

    2010-12-01

    Full Text Available Sub-ice shelf circulation and freezing/melting rates in ocean general circulation models depend critically on an accurate and consistent representation of cavity geometry. Existing global or pan-Antarctic topography data sets have turned out to contain various inconsistencies and inaccuracies. The goal of this work is to compile independent regional surveys and maps into a global data set. We use the S-2004 global 1-min bathymetry as the backbone and add an improved version of the BEDMAP topography (ALBMAP bedrock topography for an area that roughly coincides with the Antarctic continental shelf. The position of the merging line is individually chosen in different sectors in order to capture the best of both data sets. High-resolution gridded data for ice shelf topography and cavity geometry of the Amery, Fimbul, Filchner-Ronne, Larsen C and George VI Ice Shelves, and for Pine Island Glacier are carefully merged into the ambient ice and ocean topographies. Multibeam survey data for bathymetry in the former Larsen B cavity and the southeastern Bellingshausen Sea have been obtained from the data centers of Alfred Wegener Institute (AWI, British Antarctic Survey (BAS and Lamont-Doherty Earth Observatory (LDEO, gridded, and blended into the existing bathymetry map. The resulting global 1-min Refined Topography data set (RTopo-1 contains self-consistent maps for upper and lower ice surface heights, bedrock topography, and surface type (open ocean, grounded ice, floating ice, bare land surface. The data set is available in NetCDF format from the PANGAEA database at doi:10.1594/pangaea.741917.

  17. ATM Coastal Topography-Texas, 2001: UTM Zone 15

    Science.gov (United States)

    Klipp, Emily S.; Nayegandhi, Amar; Brock, John C.; Sallenger, A.H.; Bonisteel, Jamie M.; Yates, Xan; Wright, C. Wayne

    2009-01-01

    These remotely sensed, geographically referenced elevation measurements of lidar-derived first-surface (FS) topography were produced collaboratively by the U.S. Geological Survey (USGS), Florida Integrated Science Center (FISC), St. Petersburg, FL, and the National Aeronautics and Space Administration (NASA), Wallops Flight Facility, VA. This project provides highly detailed and accurate datasets of a portion of the Texas coastline within UTM zone 15, from Matagorda Peninsula to Galveston Island, acquired October 12-13, 2001. The datasets are made available for use as a management tool to research scientists and natural-resource managers. An innovative scanning lidar instrument originally developed by NASA, and known as the Airborne Topographic Mapper (ATM), was used during data acquisition. The ATM system is a scanning lidar system that measures high-resolution topography of the land surface and incorporates a green-wavelength laser operating at pulse rates of 2 to 10 kilohertz. Measurements from the laser-ranging device are coupled with data acquired from inertial navigation system (INS) attitude sensors and differentially corrected global positioning system (GPS) receivers to measure topography of the surface at accuracies of +/-15 centimeters. The nominal ATM platform is a Twin Otter or P-3 Orion aircraft, but the instrument may be deployed on a range of light aircraft. Elevation measurements were collected over the survey area using the ATM system, and the resulting data were then processed using the Airborne Lidar Processing System (ALPS), a custom-built processing system developed in a NASA-USGS collaboration. ALPS supports the exploration and processing of lidar data in an interactive or batch mode. Modules for presurvey flight-line definition, flight-path plotting, lidar raster and waveform investigation, and digital camera image playback have been developed. Processing algorithms have been developed to extract the range to the first and last significant

  18. Magneto-optical labeling of fetal neural stem cells for in vivo MRI tracking.

    Science.gov (United States)

    Flexman, J A; Minoshima, S; Kim, Y; Cross, D J

    2006-01-01

    Neural stem cell therapy for neurological pathologies, such as Alzheimer's and Parkinson's disease, may delay the onset of symptoms, replace damaged neurons and/or support the survival of endogenous cells. Magnetic resonance imaging (MRI) can be used to track magnetically labeled cells in vivo to observe migration. Prior to transplantation, labeled cells must be characterized to show that they retain their intrinsic properties, such as cell proliferation into neurospheres in a supplemented environment. In vivo images must also be correlated to sensitive, histological markers. In this study, we show that fetus-derived neural stem cells can be co-labeled with superparamagnetic iron oxide and PKH26, a fluorescent dye. Labeled cells retain the ability to proliferate into neurospheres in culture, but labeling prevents neurospheres from merging in a non-adherent culture environment. After labeled NSCs were transplantation into the rat brain, their location and subsequent migration along the corpus callosum was detected using MRI. This study demonstrates an imaging paradigm with which to develop an in vivo assay for quantitatively evaluating fetal neural stem cell migration.

  19. Snap evaporation of droplets on smooth topographies.

    Science.gov (United States)

    Wells, Gary G; Ruiz-Gutiérrez, Élfego; Le Lirzin, Youen; Nourry, Anthony; Orme, Bethany V; Pradas, Marc; Ledesma-Aguilar, Rodrigo

    2018-04-11

    Droplet evaporation on solid surfaces is important in many applications including printing, micro-patterning and cooling. While seemingly simple, the configuration of evaporating droplets on solids is difficult to predict and control. This is because evaporation typically proceeds as a "stick-slip" sequence-a combination of pinning and de-pinning events dominated by static friction or "pinning", caused by microscopic surface roughness. Here we show how smooth, pinning-free, solid surfaces of non-planar topography promote a different process called snap evaporation. During snap evaporation a droplet follows a reproducible sequence of configurations, consisting of a quasi-static phase-change controlled by mass diffusion interrupted by out-of-equilibrium snaps. Snaps are triggered by bifurcations of the equilibrium droplet shape mediated by the underlying non-planar solid. Because the evolution of droplets during snap evaporation is controlled by a smooth topography, and not by surface roughness, our ideas can inspire programmable surfaces that manage liquids in heat- and mass-transfer applications.

  20. Trans-eyebrow supraorbital approach in large suprasellar craniopharyngioma surgery in adults: analysis of optic nerve length and extent of tumor resection. Original article.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inma; Evangelista, Rocío; Pancucci, Giovanni; Guarín, Juliana; Ayuso, Angel; Misra, Mukesh

    2017-05-01

    One of the main drawbacks in the surgery of large craniopharyngiomas is the presence of a prefixed optic chiasm. Our main objective in this study is to compare the predictive value of the optic nerve length and optic chiasm location on large craniopharyngiomas' extent of resection. We retrospectively studied 21 consecutive patients with large craniopharyngiomas who underwent tumor resection through the trans-eyebrow supraorbital approach. Clinical and radiological findings on preoperative MRI were recorded, including the optic chiasm location classified as prefixed, postfixed or normal. We registered the optic nerve length measured intraoperatively prior to tumor removal and confirmed the measurements on preoperative MRI. Using a linear regression model, we calculated a prediction formula of the percentage of the extent of resection as a function of optic nerve length. On preoperative MRI, 15 patients were considered to have an optic chiasm in a normal location, 3 cases had a prefixed chiasm, and the remaining 3 had a postfixed chiasm. In the group with normal optic chiasm location, a wide range of percentage of extent of resection was observed (75-100%). The percentage of extent of resection of large craniopharyngiomas was observed to be dependent on the optic nerve length in a linear regression model (p < 0.0001). According to this model in the normal optic chiasm location group, we obtained an 87% resection in 9-mm optic nerve length patients, a 90.5% resection in 10-mm optic nerve length patients and 100% resection in 11-mm optic nerve length patients. Optic chiasm location provides useful information to predict the percentage of resection in both prefixed and postfixed chiasm patients but not in the normal optic chiasm location group. Optic nerve length was proven to provide a more accurate way to predict the percentage of resection than the optic chiasm location in the normal optic chiasm location group.

  1. Assessment of ameloblastomas using MRI and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Asaumi, Jun-ichi; Hisatomi, Miki; Yanagi, Yoshinobu; Matsuzaki, Hidenobu; Choi, Yong Suk; Kawai, Noriko; Konouchi, Hironobu; Kishi, Kanji

    2005-01-01

    We retrospectively evaluated magnetic resonance images (MRI) and dynamic contrast-enhanced MRI (DCE-MRI) of ameloblastomas. MRI and DCE-MRI were performed for 10 ameloblastomas. We obtained the following results from the MRI and DCE-MRI. (a) Ameloblastomas can be divided into solid and cystic portions on the basis of MR signal intensities. (b) Ameloblastomas show a predilection for intermediate signal intensity on T1WI, high signal intensity on T2WI, and well enhancement in the solid portion; they also show a homogeneous intermediate signal intensity on T1WI and homogeneous high signal intensity on T2WI, and no enhancement in the cystic portion. (c) The mural nodule or thick wall can be detected in ameloblastomas lesions. (d) CI curves of ameloblastomas show two patterns: the first pattern increases, reaches a plateau at 100-300 s, then sustains the plateau or decreases gradually to 600-900 s, while the other increases relatively rapidly, reaches a plateau at 90-120 s, then decreases relatively rapidly to 300 s, and decreases gradually thereafter. There was no difference in the CI curve patterns among primary and recurrent cases, a case with glandular odontogenic tumor in ameloblastoma or among histopathological types such as plexiform, follicular, mixed, desmoplastic, and unicystic type

  2. Atmospheric stability and topography effects on wind turbine performance and wake properties in complex terrain

    DEFF Research Database (Denmark)

    Han, Xingxing; Liu, Deyou; Xu, Chang

    2018-01-01

    This paper evaluates the influence of atmospheric stability and topography on wind turbine performance and wake properties in complex terrain. To assess atmospheric stability effects on wind turbine performance, an equivalent wind speed calculated with the power output and the manufacture power...... and topography have significant influences on wind turbine performance and wake properties. Considering effects of atmospheric stability and topography will benefit the wind resource assessment in complex terrain....

  3. The Role of Membrane Curvature in Nanoscale Topography-Induced Intracellular Signaling.

    Science.gov (United States)

    Lou, Hsin-Ya; Zhao, Wenting; Zeng, Yongpeng; Cui, Bianxiao

    2018-05-15

    Over the past decade, there has been growing interest in developing biosensors and devices with nanoscale and vertical topography. Vertical nanostructures induce spontaneous cell engulfment, which enhances the cell-probe coupling efficiency and the sensitivity of biosensors. Although local membranes in contact with the nanostructures are found to be fully fluidic for lipid and membrane protein diffusions, cells appear to actively sense and respond to the surface topography presented by vertical nanostructures. For future development of biodevices, it is important to understand how cells interact with these nanostructures and how their presence modulates cellular function and activities. How cells recognize nanoscale surface topography has been an area of active research for two decades before the recent biosensor works. Extensive studies show that surface topographies in the range of tens to hundreds of nanometers can significantly affect cell functions, behaviors, and ultimately the cell fate. For example, titanium implants having rough surfaces are better for osteoblast attachment and host-implant integration than those with smooth surfaces. At the cellular level, nanoscale surface topography has been shown by a large number of studies to modulate cell attachment, activity, and differentiation. However, a mechanistic understanding of how cells interact and respond to nanoscale topographic features is still lacking. In this Account, we focus on some recent studies that support a new mechanism that local membrane curvature induced by nanoscale topography directly acts as a biochemical signal to induce intracellular signaling, which we refer to as the curvature hypothesis. The curvature hypothesis proposes that some intracellular proteins can recognize membrane curvatures of a certain range at the cell-to-material interface. These proteins then recruit and activate downstream components to modulate cell signaling and behavior. We discuss current technologies

  4. Seeing the sound after visual loss: functional MRI in acquired auditory-visual synesthesia.

    Science.gov (United States)

    Yong, Zixin; Hsieh, Po-Jang; Milea, Dan

    2017-02-01

    Acquired auditory-visual synesthesia (AVS) is a rare neurological sign, in which specific auditory stimulation triggers visual experience. In this study, we used event-related fMRI to explore the brain regions correlated with acquired monocular sound-induced phosphenes, which occurred 2 months after unilateral visual loss due to an ischemic optic neuropathy. During the fMRI session, 1-s pure tones at various pitches were presented to the patient, who was asked to report occurrence of sound-induced phosphenes by pressing one of the two buttons (yes/no). The brain activation during phosphene-experienced trials was contrasted with non-phosphene trials and compared to results obtained in one healthy control subject who underwent the same fMRI protocol. Our results suggest, for the first time, that acquired AVS occurring after visual impairment is associated with bilateral activation of primary and secondary visual cortex, possibly due to cross-wiring between auditory and visual sensory modalities.

  5. Comparison of Ct and MRI in the study of the pituitary gland

    International Nuclear Information System (INIS)

    Juliani, G.; Avataneo, T.; Potenzoni, F.; Sorrentino, T

    1989-01-01

    Normal CT and MR anatomy was studied in two series (53 and 25 cases respectively) of young volunteers of both sexes, asymptomatic and certainly without lesions of the pituitary gland. 115 other pathological cases (73 hyperprolactinemias, 8 acromegalies, 15 Cushing syndromes, 2 hyperthyroidisms, 17 non-secreting adenomas) were examined using both CT and MRI. Both an accurate review of the relative literature and the results of our own series prove that MR is superior to CT in diagnosing pituitary microadenomas (3.2% not diagnosed with MRI and 25.8% not diagnosed with CT), in the follow-up of prolactinomas subjected to medical therapy and in the study of extrasellar involvement of pituitery adenomas, particularly with regard to the demonstration of compression of the optic chiasma

  6. Synchrotron-radiation plane-wave topography

    International Nuclear Information System (INIS)

    Riglet, P.; Sauvage, M.; Petroff, J.F.; Epelboin, Y.

    1980-01-01

    A computer program based on the Takagi-Taupin differential equations for X-ray propagation in distorted crystals has been developed in order to simulate dislocation images in the Bragg case. The program is valid both for thin and thick crystals. Simulated images of misfit dislocations formed either in a thin epilayer or in a thick substrate are compared with experimental images obtained by synchrotron-radiation plane-wave topography. The influence of the various strain components on the image features is discussed. (author)

  7. Cortical neuroplasticity in patients recovering from acute optic neuritis

    DEFF Research Database (Denmark)

    Korsholm, Kirsten; Madsen, Kristoffer Hougaard; Frederiksen, Jette L.

    2008-01-01

    MRI, to reveal a clearer pattern of neuroplasticity, across a mixed patient population. A longitudinal fMRI-study of visual function in 19 ON patients examined at four timepoints between presentation and 6 months was performed. Four different models were compared. The first model included the four different......Patients with optic neuritis (ON) undergo cortical and subcortical neuroplasticity as revealed by functional magnetic resonance imaging (fMRI). However, the effect of the heterogeneity of scotomas his not been adequately addressed previously. We introduce a new method of modelling scotomas in f...... examination timepoints as separate explanatory variables without adjustment for Visual held defects. The second model also included covariates reflecting subject-specific deviations in Visual field defect from the average group value of the Humphrey mean deviation (HMD) at each examination timepoint...

  8. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  9. Chest MRI

    Science.gov (United States)

    ... resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI Patient Instructions ... Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology. In: Broaddus VC, Mason RJ, Ernst JD, et ...

  10. High resolution, monochromatic x-ray topography capability at CHESS

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, K. D., E-mail: kdf1@cornell.edu; Pauling, A.; Brown, Z. [CHESS, Cornell University, Ithaca, NY (United States); Jones, R. [Department of Physics, University of Connecticut, Storrs, CT (United States); Tarun, A.; Misra, D. S. [IIa Technologies (Singapore); Jupitz, S. [St. Mary’s College of Maryland, St. Mary’s City, MD (United States); Sagan, D. C. [CLASSE, Cornell University, Ithaca, NY (United States)

    2016-07-27

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  11. High resolution, monochromatic x-ray topography capability at CHESS

    International Nuclear Information System (INIS)

    Finkelstein, K. D.; Pauling, A.; Brown, Z.; Jones, R.; Tarun, A.; Misra, D. S.; Jupitz, S.; Sagan, D. C.

    2016-01-01

    CHESS has a monochromatic x-ray topography capability serving continually expanding user interest. The setup consists of a beam expanding monochromator, 6-circle diffactometer, and CHESS designed CMOS camera with real time sample-alignment capability. This provides rocking curve mapping with angle resolution as small as 2 µradians, spatial resolution to 3 microns, and field of view up to 7mm. Thus far the capability has been applied for: improving CVD-diamond growth, evaluating perfection of ultra-thin diamond membranes, correlating performance of diamond-based electronics with crystal defect structure, and defect analysis of single crystal silicon carbide. This paper describes our topography system, explains its capabilities, and presents experimental results from several applications.

  12. SRTM Radar Image, Wrapped Color as Height/EarthKam Optical Honolulu, Hawaii

    Science.gov (United States)

    2000-01-01

    These two images of the eastern part of the island of Oahu, Hawaii provide information on regional topography and show the relationship between urban development and sensitive ecosystems. On the left is a topographic radar image collected by the Shuttle Radar Topography Mission (SRTM.) On the right is an optical image acquired by a digital camera on the Space Shuttle Endeavour, which carried SRTM. Features of interest in this scene include Diamond Head (an extinct volcano at the lower center), Waikiki Beach (just left of Diamond Head), the Punchbowl National Cemetery (another extinct volcano, at the foot of the Koolau Mountains), downtown Honolulu and Honolulu airport (lower left of center), and Pearl Harbor (at the left edge.)The topography shows the steep, high central part of the island surrounded by flatter coastal areas. The optical image shows the urban areas and a darker, forested region on the mountain slopes. The clouds in the optical image and the black areas on the topographic image are both a result of the steep topography. In this tropical region, high mountain peaks are usually covered in clouds. These steep peaks also cause shadows in the radar data, resulting in missing data 'holes.' A second pass over the island was obtained by SRTM and will be used to fill in the holes.The left image combines two types of SRTM data. Brightness corresponds to the strength of the radar signal reflected from the ground, while colors show the elevation. Each color cycle (from pink through blue and back to pink) represents 400 meters (1,300 feet) of elevation difference, like the contour lines on a topographic map. This image contains about 2,400 meters (8,000 feet) of total relief. The optical image was acquired by the Shuttle Electronic Still Camera with a lens focal length of 64 millimeters (2.5 inches) for the Earth Knowledge Acquired by Middle school students (EarthKAM) project. EarthKAM has flown on five space shuttle missions since 1996. Additional information

  13. Characteristics of seizure-induced signal changes on MRI in patients with first seizures.

    Science.gov (United States)

    Kim, Si Eun; Lee, Byung In; Shin, Kyong Jin; Ha, Sam Yeol; Park, JinSe; Park, Kang Min; Kim, Hyung Chan; Lee, Joonwon; Bae, Soo-Young; Lee, Dongah; Kim, Sung Eun

    2017-05-01

    The aim of this study was to investigate the predictive factors and identify the characteristics of the seizure-induced signal changes on MRI (SCM) in patients with first seizures. We conducted a retrospective study of patients with first seizures from March 2010 to August 2014. The inclusion criteria for this study were patients with 1) first seizures, and 2) MRI and EEG performed within 24h of the first seizures. The definition of SCM was hyper-intensities in the brain not applying to cerebral arterial territories. Multivariate logistic regression was performed with or without SCM as a dependent variable. Of 431 patients with seizures visiting the ER, 69 patients met the inclusion criteria. Of 69 patients, 11 patients (15.9%) had SCM. Epileptiform discharge on EEG (OR 29.7, 95% CI 1.79-493.37, p=0.018) was an independently significant variable predicting the presence of SCM in patients with first seizures. In addition, the topography of SCM was as follows; i) ipsilateral hippocampus, thalamus and cerebral cortex (5/11), ii) unilateral cortex (4/11), iii) ipsilateral thalamus and cerebral cortex (1/11), iv) bilateral hippocampus (1/11). Moreover, 6 out of 7 patients who underwent both perfusion CT and MRI exhibited unilateral cortical hyperperfusion with ipsilateral thalamic involvement reflecting unrestricted vascular territories. There is an association between epileptiform discharges and SCM. Additionally, the involvement of the unilateral cortex and ipsilateral thalamus in SCM and its hyperperfusion state could be helpful in differentiating the consequences of epileptic seizures from other pathologies. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  14. Optical microscope for three-dimensional surface displacement and shape measurements at the microscale.

    Science.gov (United States)

    Xia, Shuman; Pan, Zhipeng; Zhang, Jingwen

    2014-07-15

    We report a novel optical microscope for full-field, noncontact measurements of three-dimensional (3D) surface deformation and topography at the microscale. The microscope system is based on a seamless integration of the diffraction-assisted image correlation (DAIC) method with fluorescent microscopy. We experimentally demonstrate the microscope's capability for 3D measurements with submicrometer spatial resolution and subpixel measurement accuracy.

  15. MRI in psychiatry

    International Nuclear Information System (INIS)

    Mulert, Christoph; Shenton, Martha E.

    2014-01-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  16. MRI in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Mulert, Christoph [UKE, Hamburg (Germany). Psychiatry Neuroimaging Branch; Shenton, Martha E. (ed.) [Harvard Medical School, Boston, MA (United States). Dept. of Psychiatry and Radiology

    2014-07-01

    This is the first comprehensive textbook on the use of MRI in psychiatry covering imaging techniques, brain systems and a review of findings in different psychiatric disorders. The book is divided into three sections, the first of which covers in detail all the major MRI-based methodological approaches available today, including fMRI, EEG-fMRI, DTI, and MR spectroscopy. In addition, the role of MRI in imaging genetics and combined brain stimulation and imaging is carefully explained. The second section provides an overview of the different brain systems that are relevant for psychiatric disorders, including the systems for perception, emotion, cognition, and reward. The final part of the book presents the MRI findings that are obtained in all the major psychiatric disorders using the previously discussed techniques. Numerous carefully chosen images support the informative text, making this an ideal reference work for all practitioners and trainees with an interest in this flourishing field.

  17. Learning topography with Tangible Landscape games

    Science.gov (United States)

    Petrasova, A.; Tabrizian, P.; Harmon, B. A.; Petras, V.; Millar, G.; Mitasova, H.; Meentemeyer, R. K.

    2017-12-01

    Understanding topography and its representations is crucial for correct interpretation and modeling of surface processes. However, novice earth science and landscape architecture students often find reading topographic maps challenging. As a result, many students struggle to comprehend more complex spatial concepts and processes such as flow accumulation or sediment transport.We developed and tested a new method for teaching hydrology, geomorphology, and grading using Tangible Landscape—a tangible interface for geospatial modeling. Tangible Landscape couples a physical and digital model of a landscape through a real-time cycle of hands-on modeling, 3D scanning, geospatial computation, and projection. With Tangible Landscape students can sculpt a projection-augmented topographic model of a landscape with their hands and use a variety of tangible objects to immediately see how they are changing geospatial analytics such as contours, profiles, water flow, or landform types. By feeling and manipulating the shape of the topography, while seeing projected geospatial analytics, students can intuitively learn about 3D topographic form, its representations, and how topography controls physical processes. Tangible Landscape is powered by GRASS GIS, an open source geospatial platform with extensive libraries for geospatial modeling and analysis. As such, Tangible Landscape can be used to design a wide range of learning experiences across a large number of geoscience disciplines.As part of a graduate level course that teaches grading, 16 students participated in a series of workshops, which were developed as serious games to encourage learning through structured play. These serious games included 1) diverting rain water to a specified location with minimal changes to landscape, 2) building different combinations of landforms, and 3) reconstructing landscapes based on projected contour information with feedback.In this poster, we will introduce Tangible Landscape, and

  18. Spectrum of MRI findings in 58 patients with methanol intoxication: Long-term visual and neurological correlation

    Directory of Open Access Journals (Sweden)

    Sahar M. Elkhamary

    2016-09-01

    Conclusion: Spectrum of residual MRI Findings in patients who survived methanol poisoning included bilateral optic nerve atrophy and enhancement, bilateral putamen and caudate necrosis as well as subcortical white matter high SI at T2WI. Diffusion WI did not have additional value in chronic stage.

  19. Cellular Scale Anisotropic Topography Guides Schwann Cell Motility

    Science.gov (United States)

    Mitchel, Jennifer A.; Hoffman-Kim, Diane

    2011-01-01

    Directed migration of Schwann cells (SC) is critical for development and repair of the peripheral nervous system. Understanding aspects of motility specific to SC, along with SC response to engineered biomaterials, may inform strategies to enhance nerve regeneration. Rat SC were cultured on laminin-coated microgrooved poly(dimethyl siloxane) platforms that were flat or presented repeating cellular scale anisotropic topographical cues, 30 or 60 µm in width, and observed with timelapse microscopy. SC motion was directed parallel to the long axis of the topography on both the groove floor and the plateau, with accompanying differences in velocity and directional persistence in comparison to SC motion on flat substrates. In addition, feature dimension affected SC morphology, alignment, and directional persistence. Plateaus and groove floors presented distinct cues which promoted differential motility and variable interaction with the topographical features. SC on the plateau surfaces tended to have persistent interactions with the edge topography, while SC on the groove floors tended to have infrequent contact with the corners and walls. Our observations suggest the capacity of SC to be guided without continuous contact with a topographical cue. SC exhibited a range of distinct motile morphologies, characterized by their symmetry and number of extensions. Across all conditions, SC with a single extension traveled significantly faster than cells with more or no extensions. We conclude that SC motility is complex, where persistent motion requires cellular asymmetry, and that anisotropic topography with cellular scale features can direct SC motility. PMID:21949703

  20. [Fusion of MRI, fMRI and intraoperative MRI data. Methods and clinical significance exemplified by neurosurgical interventions].

    Science.gov (United States)

    Moche, M; Busse, H; Dannenberg, C; Schulz, T; Schmitgen, A; Trantakis, C; Winkler, D; Schmidt, F; Kahn, T

    2001-11-01

    The aim of this work was to realize and clinically evaluate an image fusion platform for the integration of preoperative MRI and fMRI data into the intraoperative images of an interventional MRI system with a focus on neurosurgical procedures. A vertically open 0.5 T MRI scanner was equipped with a dedicated navigation system enabling the registration of additional imaging modalities (MRI, fMRI, CT) with the intraoperatively acquired data sets. These merged image data served as the basis for interventional planning and multimodal navigation. So far, the system has been used in 70 neurosurgical interventions (13 of which involved image data fusion--requiring 15 minutes extra time). The augmented navigation system is characterized by a higher frame rate and a higher image quality as compared to the system-integrated navigation based on continuously acquired (near) real time images. Patient movement and tissue shifts can be immediately detected by monitoring the morphological differences between both navigation scenes. The multimodal image fusion allowed a refined navigation planning especially for the resection of deeply seated brain lesions or pathologies close to eloquent areas. Augmented intraoperative orientation and instrument guidance improve the safety and accuracy of neurosurgical interventions.

  1. Influence of local topography on precision irrigation management

    Science.gov (United States)

    Precision irrigation management is currently accomplished using spatial information about soil properties through soil series maps or electrical conductivity (EC measurements. Crop yield, however, is consistently influenced by local topography, both in rain-fed and irrigated environments. Utilizing ...

  2. Diagnostic value of MRI in meniscus injury. Comparison of MRI and arthrography

    International Nuclear Information System (INIS)

    Iso, Yoshinori; Nozaki, Hiroyuki; Emoto, Mari; Miyairi, Taro; Hirata, Aya; Hirasawa, Seiichi; Suguro, Toru; Igata, Atsuomi; Kudo, Yukihiko.

    1995-01-01

    Magnetic resonance imaging (MRI) and arthrography were performed on 90 knees to compare the diagnostic value for meniscus injury with these techniques. The diagnostic accuracy of MRI and arthrography was 89.1% and 87.1%, respectively. Imaging of the medial meniscus was somewhat better with arthrography, and delineation of the lateral meniscus was somewhat better with MRI. MRI was superior in diagnoses of horizontal and degenerative lacerations, but showed the shape of the injuries less clearly than arthrography. The diagnostic accuracy of MRI decreased with the age of the patients and was inferior to arthrography for patients in their forties or older. In conclusion, MRI is a less invasive approach with high diagnostic accuracy for meniscus injury and is a promising substitute for arthrography. (author)

  3. Toxocara optic neuropathy: clinical features and ocular findings.

    Science.gov (United States)

    Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho

    2018-01-01

    We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final ( P =0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis.

  4. Toxocara optic neuropathy: clinical features and ocular findings

    Science.gov (United States)

    Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho

    2018-01-01

    We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final (P=0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis. PMID:29600190

  5. Stresses in a submarine topography under ocean waves

    Energy Technology Data Exchange (ETDEWEB)

    Mei, C.C.; McTigue, D.F.

    1984-09-01

    The problem of submarine slope stability is of interest to both offshore engineering and geology. In an uneven topography, the weight above a horizontal plane induces two-dimensional variation in the static stress field. The action of wave pressure, which changes with depth, further introduces excess pore pressure and dynamic stresses in the sea bottom. In the present paper, we combine a simple analytical theory for the static stress by the present authors, and the recent solution by Mei and Foda for wave-induced stresses in a plane poro-elastic sea bed to account for mild bottom slope and wave shoaling, and obtain the effective stress field in a submarine topography under sea waves. Sample results are given for a ridge and a canyon. In particular, the dynamic pore pressure and the combined static and dynamic effective stresses are presented.

  6. Structural Characterization of Doped GaSb Single Crystals by X-ray Topography

    Energy Technology Data Exchange (ETDEWEB)

    Honnicke, M.G.; Mazzaro, I.; Manica, J.; Benine, E.; M da Costa, E.; Dedavid, B. A.; Cusatis, C.; Huang, X. R.

    2009-09-13

    We characterized GaSb single crystals containing different dopants (Al, Cd and Te), grown by the Czochralski method, by x-ray topography and high angular resolution x-ray diffraction. Lang topography revealed dislocations parallel and perpendicular to the crystal's surface. Double-crystal GaSb 333 x-ray topography shows dislocations and vertical stripes than can be associated with circular growth bands. We compared our high-angular resolution x-ray diffraction measurements (rocking curves) with the findings predicted by the dynamical theory of x-ray diffraction. These measurements show that our GaSb single crystals have a relative variation in the lattice parameter ({Delta}d/d) on the order of 10{sup -5}. This means that they can be used as electronic devices (detectors, for example) and as x-ray monochromators.

  7. Abnormal lateral geniculate nucleus and optic chiasm in human albinism.

    Science.gov (United States)

    Mcketton, Larissa; Kelly, Krista R; Schneider, Keith A

    2014-08-01

    Our objective was to measure how the misrouting of retinal ganglion cell (RGC) fibers affects the organization of the optic chiasm and lateral geniculate nuclei (LGN) in human albinism. We compared the chiasmal structures and the LGN in both pigmented controls and patients with albinism by using high-resolution structural magnetic resonance imaging (MRI). We studied 12 patients with oculocutaneous albinism and 12 age-matched pigmented controls. Using a 3T MRI scanner, we acquired a T1 -weighted three-dimensional magnetization-prepared rapid gradient-echo (MPRAGE) image of the whole brain, oriented so that the optic nerves, chiasm, and tracts were in the same plane. We acquired multiple proton density-weighted images centered on the thalamus and midbrain, and averaged them to increase the signal, enabling precise manual tracing of the anatomical boundaries of the LGN. Albinism patients exhibited significantly smaller diameters of the optic nerves, chiasm and tracts, and optic chiasm and LGN volume compared with controls (P albinism compared with the control group can be attributed to the abnormal crossing of optic fibers and the reduction of RGCs in the central retina. The volume of the LGN devoted to the center of the visual field may be reduced in albinism due to fewer RGCs representing the area where the fovea would normally lie. Our data may be clinically useful in addressing how genetic deficits compromise proper structural and functional development in the brain. © 2014 Wiley Periodicals, Inc.

  8. Automatic spinal cord localization, robust to MRI contrasts using global curve optimization.

    Science.gov (United States)

    Gros, Charley; De Leener, Benjamin; Dupont, Sara M; Martin, Allan R; Fehlings, Michael G; Bakshi, Rohit; Tummala, Subhash; Auclair, Vincent; McLaren, Donald G; Callot, Virginie; Cohen-Adad, Julien; Sdika, Michaël

    2018-02-01

    During the last two decades, MRI has been increasingly used for providing valuable quantitative information about spinal cord morphometry, such as quantification of the spinal cord atrophy in various diseases. However, despite the significant improvement of MR sequences adapted to the spinal cord, automatic image processing tools for spinal cord MRI data are not yet as developed as for the brain. There is nonetheless great interest in fully automatic and fast processing methods to be able to propose quantitative analysis pipelines on large datasets without user bias. The first step of most of these analysis pipelines is to detect the spinal cord, which is challenging to achieve automatically across the broad range of MRI contrasts, field of view, resolutions and pathologies. In this paper, a fully automated, robust and fast method for detecting the spinal cord centerline on MRI volumes is introduced. The algorithm uses a global optimization scheme that attempts to strike a balance between a probabilistic localization map of the spinal cord center point and the overall spatial consistency of the spinal cord centerline (i.e. the rostro-caudal continuity of the spinal cord). Additionally, a new post-processing feature, which aims to automatically split brain and spine regions is introduced, to be able to detect a consistent spinal cord centerline, independently from the field of view. We present data on the validation of the proposed algorithm, known as "OptiC", from a large dataset involving 20 centers, 4 contrasts (T 2 -weighted n = 287, T 1 -weighted n = 120, T 2 ∗ -weighted n = 307, diffusion-weighted n = 90), 501 subjects including 173 patients with a variety of neurologic diseases. Validation involved the gold-standard centerline coverage, the mean square error between the true and predicted centerlines and the ability to accurately separate brain and spine regions. Overall, OptiC was able to cover 98.77% of the gold-standard centerline, with a

  9. Smoking Through a Topography Device Diminishes Some of the Acute Rewarding Effects of Smoking.

    Science.gov (United States)

    Ross, Kathryn C; Juliano, Laura M

    2016-05-01

    Smoking topography (ST) devices are an important methodological tool for quantifying puffing behavior (eg, puff volume, puff velocity) as well as identifying puffing differences across individuals and situations. Available ST devices are designed such that the smoker's mouth and hands have direct contact with the device rather than the cigarette itself. Given the importance of the sensorimotor aspects of cigarette smoking in smoking reward, it is possible that ST devices may interfere with the acute rewarding effects of smoking. Despite the methodological importance of this issue, few studies have directly compared subjective reactions to smoking through a topography device to naturalistic smoking. Smokers (N = 58; 38% female) smoked their preferred brand of cigarettes one time through a portable topography device and one time naturalistically, in counterbalanced order across two laboratory sessions. Smoking behavior (eg, number of puffs) and subjective effects (eg, urge reduction, affect, smoking satisfaction) were assessed. Negative affect reduction was greater in the natural smoking condition relative to the topography condition, but differences were not significant on measures of urge, withdrawal, or positive affect. Self-reported smoking satisfaction, enjoyment of respiratory tract sensations, psychological reward, craving reduction, and other rewarding effects of smoking were also significantly greater in the naturalistic smoking condition. The effects of using a ST device on the smoking experience should be considered when it is used in research as it may diminish some of the rewarding effects of smoking. When considering the inclusion of a smoking topography device in one's research, it is important to know if use of that device will alter the smoker's experience. This study assessed affective and subjective reactions to smoking through a topography device compared to naturalistic smoking. We found that smoking satisfaction, psychological reward, enjoyment

  10. Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Sakurai, Kota; Nakano, Masahiro; Maeda, Sunaho; Kajita, Kimihiro R.T.; Deguchi, Takashi; Hoshi, Hiroaki

    2006-01-01

    Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 ± 6.17 cc (mean ± SD) in MRI-based dosimetry, and 15.97 ± 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported

  11. Diffusion, confusion and functional MRI

    International Nuclear Information System (INIS)

    Le Bihan, Denis

    2012-01-01

    Diffusion MRI has been introduced in 1985 and has had a very successful life on its own. While it has become a standard for imaging stroke and white matter disorders, the borders between diffusion MRI and the general field of fMRI have always remained fuzzy. First, diffusion MRI has been used to obtain images of brain function, based on the idea that diffusion MRI could also be made sensitive to blood flow, through the intra-voxel incoherent motion (IVIM) concept. Second, the IVIM concept helped better understand the contribution from different vasculature components to the BOLD fMRI signal. Third, it has been shown recently that a genuine fMRI signal can be obtained with diffusion MRI. This 'DfMRI' signal is notably different from the BOLD fMRI signal, especially for its much faster response to brain activation both at onset and offset, which points out to structural changes in the neural tissues, perhaps such as cell swelling, occurring in activated neural tissue. This short article reviews the major steps which have paved the way for this exciting development, underlying how technical progress with MRI equipment has each time been instrumental to expand the horizon of diffusion MRI toward the field of fMRI. (authors)

  12. Time-domain full-waveform inversion of Rayleigh and Love waves in presence of free-surface topography

    Science.gov (United States)

    Pan, Yudi; Gao, Lingli; Bohlen, Thomas

    2018-05-01

    Correct estimation of near-surface seismic-wave velocity when encountering lateral heterogeneity and free surface topography is one of the challenges to current shallow seismic. We propose to use time-domain full-waveform inversion (FWI) of surface waves, including both Rayleigh and Love waves, to solve this problem. We adopt a 2D time-domain finite-difference method with an improved vacuum formulation (IVF) to simulate shallow-seismic Rayleigh wave in presence of free-surface topography. We modify the IVF for SH-wave equation for the simulation of Love wave in presence of topographic free surface and prove its accuracy by benchmark tests. Checkboard model tests are performed in both cases when free-surface topography is included or neglected in FWI. Synthetic model containing a dipping planar free surface and lateral heterogeneity was then tested, in both cases of considering and neglecting free-surface topography. Both checkerboard and synthetic models show that Rayleigh- and Love-wave FWI have similar ability of reconstructing near-surface structures when free-surface topography is considered, while Love-wave FWI could reconstruct near-surface structures better than Rayleigh-wave when free-surface topography is neglected.

  13. CT and MRI findings of 144 patients with West syndrome. Characterization of the cerebral lesion and its topography

    International Nuclear Information System (INIS)

    Hamano, Shin-ichiro; Tanaka, Manabu; Mochizuki, Mika; Sugiyama, Nobuyoshi; Nara, Takahiro; Oguma, Eiji; Eto, Yoshikatsu

    2002-01-01

    In West syndrome, although classified as a generalized epilepsy, there are some patients reported to have became seizure-free and have good outcomes in the developmental aspect after resections of localized lesions. We reviewed computed tomography and magnetic resonance imaging of 144 patients with West syndrome and classified them into four categories depending on the distribution of lesion: normal group, diffuse group, disseminated group, localized group. Thirty-three patients belong to the normal group after having reviewed images from computed tomography and magnetic resonance imaging. The diffuse group consisted of 83 patients presenting morphologic abnormalities such as, diffuse cerebral atrophy, periventricular leukomalesia or polycystic encephalomalesia; the disseminated group included 17 patients having a diagnosis of tuberoius sclerosis, multiple cortical dysplasia or multiple cortical heterotopias. The lesions of all eleven patients with localized cerebral lesions involved the temporal and/or occipital lobes. Nine of the eleven patients with localized cerebral lesions had the lesions on the right side. These results suggest that the specificity of lesion topography of temporo-occipital regions and the right-side in West syndrome will have a close correlation with normal brain maturation, from the viewpoint of development of myelination and cerebral blood flow, and related with the genesis of West syndrome. (author)

  14. CT and MRI findings of 144 patients with West syndrome. Characterization of the cerebral lesion and its topography

    Energy Technology Data Exchange (ETDEWEB)

    Hamano, Shin-ichiro; Tanaka, Manabu; Mochizuki, Mika; Sugiyama, Nobuyoshi; Nara, Takahiro; Oguma, Eiji [Saitama Children' s Medical Center, Iwatsuki (Japan); Eto, Yoshikatsu [Jikei Univ., Tokyo (Japan). School of Medicine

    2002-09-01

    In West syndrome, although classified as a generalized epilepsy, there are some patients reported to have became seizure-free and have good outcomes in the developmental aspect after resections of localized lesions. We reviewed computed tomography and magnetic resonance imaging of 144 patients with West syndrome and classified them into four categories depending on the distribution of lesion: normal group, diffuse group, disseminated group, localized group. Thirty-three patients belong to the normal group after having reviewed images from computed tomography and magnetic resonance imaging. The diffuse group consisted of 83 patients presenting morphologic abnormalities such as, diffuse cerebral atrophy, periventricular leukomalesia or polycystic encephalomalesia; the disseminated group included 17 patients having a diagnosis of tuberoius sclerosis, multiple cortical dysplasia or multiple cortical heterotopias. The lesions of all eleven patients with localized cerebral lesions involved the temporal and/or occipital lobes. Nine of the eleven patients with localized cerebral lesions had the lesions on the right side. These results suggest that the specificity of lesion topography of temporo-occipital regions and the right-side in West syndrome will have a close correlation with normal brain maturation, from the viewpoint of development of myelination and cerebral blood flow, and related with the genesis of West syndrome. (author)

  15. Examining Daily Electronic Cigarette Puff Topography Among Established and Non-established Cigarette Smokers in their Natural Environment.

    Science.gov (United States)

    Lee, Youn Ok; Nonnemaker, James M; Bradfield, Brian; Hensel, Edward C; Robinson, Risa J

    2017-10-04

    Understanding exposures and potential health effects of ecigarettes is complex. Users' puffing behavior, or topography, affects function of ecigarette devices (e.g., coil temperature) and composition of their emissions. Users with different topographies are likely exposed to different amounts of any harmful or potentially harmful constituents (HPHCs). In this study, we compare ecigarette topographies of established cigarette smokers and non-established cigarette smokers. Data measuring e-cigarette topography were collected using a wireless hand-held monitoring device in users' everyday lives over 1 week. Young adult (aged 18-25) participants (N=20) used disposable e-cigarettes with the monitor as they normally would and responded to online surveys. Topography characteristics of established versus non-established cigarette smokers were compared. On average, established cigarette smokers in the sample had larger first puff volume (130.9ml vs. 56.0ml, pvs. 651.7ml, pnon-established smokers. At marginal significance, they had longer sessions (566.3s vs. 279.7s, p=.06) and used e-cigarettes more sessions per day (5.3s vs. 3.5s, p=.14). Established cigarette smokers also used ecigarettes for longer puff durations (3.3s vs. 1.8s, pvs. 54.7ml, pnon-established smokers. At marginal significance, they had longer puff interval (38.1s vs. 21.7s, p=.05). Our results demonstrate that topography characteristics differ by level of current cigarette smoking. This suggests that exposures to constituents of e-cigarettes depends on user characteristics and that specific topography parameters may be needed for different user populations when assessing ecigarette health effects. A user's topography affects his or her exposure to HPHCs. As this study demonstrates, user characteristics, such as level of smoking, can influence topography. Thus, it is crucial to understand the topography profiles of different user types to assess the potential for population harm and to identify potentially

  16. The influence of Fe doping on the surface topography of GaN epitaxial material

    International Nuclear Information System (INIS)

    Cui Lei; Yin Haibo; Jiang Lijuan; Wang Quan; Feng Chun; Xiao Hongling; Wang Cuimei; Wang Xiaoliang; Gong Jiamin; Zhang Bo; Li Baiquan; Wang Zhanguo

    2015-01-01

    Fe doping is an effective method to obtain high resistivity GaN epitaxial material. But in some cases, Fe doping could result in serious deterioration of the GaN material surface topography, which will affect the electrical properties of two dimensional electron gas (2DEG) in HEMT device. In this paper, the influence of Fe doping on the surface topography of GaN epitaxial material is studied. The results of experiments indicate that the surface topography of Fe-doped GaN epitaxial material can be effectively improved and the resistivity could be increased after increasing the growth rate of GaN materials. The GaN material with good surface topography can be manufactured when the Fe doping concentration is 9 × 10 19 cm −3 . High resistivity GaN epitaxial material which is 1 × 10 9 Ω·cm is achieved. (paper)

  17. Influence of surface topography on the surface durability of steam oxidised sintered iron

    Directory of Open Access Journals (Sweden)

    José Daniel Biasoli de Mello

    2005-06-01

    Full Text Available Durability of surfaces has been reported as the main factor affecting tribological behavior of steam oxidised sintered iron. The presence of surface pores and their negative influence on load bearing capacity, suggest that surface topography might play an important role on the durability of the oxide layer. In this paper, the influence of compaction pressure and powder grade on surface topography, and as a consequence, its effect on the tribological behavior of steam oxidised sintered iron has been analysed. Specimens prepared from atomised iron powders with different sizes were compacted using 4 different pressures, sintered, and then subjected to steam treatment. Tribological characterisation was carried out in a reciprocating sliding wear test. Although the processing parameters affected the surface topography to a considerable extent, the main influence may be attributed to powder grade. A strong influence of surface topography on the durability distance, evaluated in terms of the evolution of contact resistance with total sliding distance, has been highlighted. Surfaces which were smoother and had high load-carrying capacity were always associated with a higher durability distance.

  18. Brief communication: A nonlinear self-similar solution to barotropic flow over varying topography

    Science.gov (United States)

    Ibanez, Ruy; Kuehl, Joseph; Shrestha, Kalyan; Anderson, William

    2018-03-01

    Beginning from the shallow water equations (SWEs), a nonlinear self-similar analytic solution is derived for barotropic flow over varying topography. We study conditions relevant to the ocean slope where the flow is dominated by Earth's rotation and topography. The solution is found to extend the topographic β-plume solution of Kuehl (2014) in two ways. (1) The solution is valid for intensifying jets. (2) The influence of nonlinear advection is included. The SWEs are scaled to the case of a topographically controlled jet, and then solved by introducing a similarity variable, η = cxnxyny. The nonlinear solution, valid for topographies h = h0 - αxy3, takes the form of the Lambert W-function for pseudo velocity. The linear solution, valid for topographies h = h0 - αxy-γ, takes the form of the error function for transport. Kuehl's results considered the case -1 ≤ γ < 1 which admits expanding jets, while the new result considers the case γ < -1 which admits intensifying jets and a nonlinear case with γ = -3.

  19. The Relationship of the MOLA Topography of Mars to the Mean Atmospheric Pressure

    Science.gov (United States)

    Smith, David E.; Zuber, Maria T.

    1999-01-01

    The MOLA topography of Mars is based on a new mean radius of the planet and new equipotential surface for the areoid. The mean atmospheric pressure surface of 6.1mbars that has been used in the past as a reference level for topography does not apply to the zero level of MOLA elevations. The MOLA mean radius of the planet is 3389508 meters and the mean equatorial radius is 339600 meters. The areoid of the zero level of the MOLA altimetry is defined to be the potential surface with the same potential as the mean equatorial radius. The MOLA topography differs from the USGS digital elevation data by approximately 1.6 km, with MOLA higher. The average pressure on the MOLA reference surface for Ls =0 is approximately 5.1 mbars and has been derived from occultation data obtained from the tracking of Viking, Mariner, and MGS spacecraft and interpolated with the aid of the Ames Mars GCM. The new topography and the new occultation data are providing a more reliable relationship between elevation and surface pressure.

  20. Human and nonhuman primate meninges harbor lymphatic vessels that can be visualized noninvasively by MRI.

    Science.gov (United States)

    Absinta, Martina; Ha, Seung-Kwon; Nair, Govind; Sati, Pascal; Luciano, Nicholas J; Palisoc, Maryknoll; Louveau, Antoine; Zaghloul, Kareem A; Pittaluga, Stefania; Kipnis, Jonathan; Reich, Daniel S

    2017-10-03

    Here, we report the existence of meningeal lymphatic vessels in human and nonhuman primates (common marmoset monkeys) and the feasibility of noninvasively imaging and mapping them in vivo with high-resolution, clinical MRI. On T2-FLAIR and T1-weighted black-blood imaging, lymphatic vessels enhance with gadobutrol, a gadolinium-based contrast agent with high propensity to extravasate across a permeable capillary endothelial barrier, but not with gadofosveset, a blood-pool contrast agent. The topography of these vessels, running alongside dural venous sinuses, recapitulates the meningeal lymphatic system of rodents. In primates, meningeal lymphatics display a typical panel of lymphatic endothelial markers by immunohistochemistry. This discovery holds promise for better understanding the normal physiology of lymphatic drainage from the central nervous system and potential aberrations in neurological diseases.