WorldWideScience

Sample records for mouse corneal endothelial

  1. Trifluoperazine: corneal endothelial phototoxicity

    International Nuclear Information System (INIS)

    Hull, D.S.; Csukas, S.; Green, K.

    1983-01-01

    Trifluoperazine is used for the treatment of psychiatric disorders. Perfusion of corneal endothelial cells with trifluoperazine-HC1 concurrent with exposure to long wavelength ultraviolet light resulted in a corneal swelling rate greater than that found in perfused corneas not exposed to ultraviolet light. Exposure of endothelial cells to 25 W incandescent light during perfusion with trifluoperazine-HC1 did not result in a higher corneal swelling rate compared to those perfused in the dark. The increased corneal swelling rate could be produced by pre-exposure of the trifluoperazine-HC1 perfusing solution to ultraviolet light suggesting the production of toxic photoproducts during exposure of trifluoperazine-HC1 to ultraviolet light. Perfusion of corneal endothelial cells with non-ultraviolet illuminated trifluoperazine-HC1 had no effect on endothelial cell membranes or ultrastructure. This is in contrast to cells perfused with trifluoperazine-HC1 that had been exposed to ultraviolet light in which there was an alteration of mitochondria and a loss of cytoplasmic homogeneity. The data imply that the trifluoperazine-HC1 photoproduct had an adverse effect on cellular transport mechanisms. The study also further demonstrates the value of the corneal endothelial cell model for identifying the physiological and anatomical changes occuring in photo-induced toxic reactions. (author)

  2. Chlorpromazine-induced corneal endothelial phototoxicity

    International Nuclear Information System (INIS)

    Hull, D.S.; Csukas, S.; Green, K.

    1982-01-01

    Chlorpromazine, which has been used extensively for the treatment of psychiatric disorders, is known to accumulate in the posterior corneal stroma, lens, and uveal tract. Because it is a phototoxic compound, the potential exists for it to cause cellular damage after light exposure. Specular microscopic perfusion of corneal endothelial cells in darkness with 0.5 mM chlorpromazine HCl resulted in a swelling rate of 18 +/- 2 micrometer/hr, whereas corneas exposed to long-wavelength ultraviolet light for 3 min in the presence of 0.5 mM chlorpromazine swelled at 37 +/- 9 micrometer/hr (p less than 0.01). Preirradiation of 0.5 mM chlorpromazine solution with ultraviolet light for 30 min and subsequent corneal perfusion with the solution resulted in a corneal swelling rate of 45 +/- 19 micrometer/hr. Cornea endothelial cells perfused with 0.5 mM chlorpromazine that was preirradiated with ultraviolet light showed marked swelling on scanning electron microscopic examination, whereas those perfused with nonirradiated chlorpromazine were flat and showed a normal mosaic pattern. Combining either 500 U/ml catalase or 290 U/ml superoxide dismutase with chlorpromazine did not alter photoinduction of corneal swelling. The data suggest that corneal endothelial chlorpromazine phototoxicity is secondary to cytotoxic products resulting from the photodynamically induced decomposition of chlorpromazine and is not caused by hydrogen peroxide or superoxide anion generated during the phototoxic reaction

  3. Corneal Endothelial Alterations in Chronic Renal Failure.

    Science.gov (United States)

    Sati, Alok; Jha, Ashok; Moulick, P S; Shankar, Sandeep; Gupta, Sandeep; Khan, M A; Dogra, Manu; Sangwan, Virender S

    2016-10-01

    To evaluate the corneal endothelial changes in patients with chronic renal failure. A total of 128 corneas of 128 subjects were studied, and 3 groups were formed. The first, the dialyzed group, composed of 32 corneas of 32 patients; the second, the nondialyzed group, composed of 34 corneas of 34 patients; and the third, the age-matched control group, composed of 64 corneas of 64 healthy subjects were examined by a specular microscope and the endothelial parameters were compared. The dialyzed group (enhanced level of toxins in the blood) was further analyzed to assess the influence of blood urea, serum creatinine, serum calcium, and serum phosphorus including the duration of dialysis on corneal endothelium. On comparing the 3 groups using analysis of variance and posthoc tests, a significant difference was found in the central corneal thickness (CCT) and endothelial cell density (CD) between the control (CCT: 506 ± 29 μm, CD: 2760 ± 304 cells/mm) and dialyzed groups (CCT: 549 ± 30 μm, CD: 2337 ± 324 cells/mm) [P chronic renal failure, more marked in patients undergoing hemodialysis and with raised blood urea level.

  4. Methods Development for the Isolation and Culture of Primary Corneal Endothelial Cells

    Science.gov (United States)

    2017-02-01

    a cell population particularly suitable for low serum propagation, provided that appropriate growth factors are available. A low serum medium...of MGK. 15. SUBJECT TERMS Cornea, chemical warfare agent, corneal endothelial cell, endothelium, growth , isolation, mouse, rabbit, porcine, in...with corneal SM exposure.2 A primary requirement in achieving this goal is to develop methods that enable the isolation of a pure CEC population and

  5. Recovery of Corneal Endothelial Cells from Periphery after Injury.

    Directory of Open Access Journals (Sweden)

    Sang Ouk Choi

    Full Text Available Wound healing of the endothelium occurs through cell enlargement and migration. However, the peripheral corneal endothelium may act as a cell resource for the recovery of corneal endothelium in endothelial injury.To investigate the recovery process of corneal endothelial cells (CECs from corneal endothelial injury.Three patients with unilateral chemical eye injuries, and 15 rabbit eyes with corneal endothelial chemical injuries were studied. Slit lamp examination, specular microscopy, and ultrasound pachymetry were performed immediately after chemical injury and 1, 3, 6, and 9 months later. The anterior chambers of eyes from New Zealand white rabbits were injected with 0.1 mL of 0.05 N NaOH for 10 min (NaOH group. Corneal edema was evaluated at day 1, 7, and 14. Vital staining was performed using alizarin red and trypan blue.Specular microscopy did not reveal any corneal endothelial cells immediately after injury. Corneal edema subsided from the periphery to the center, CEC density increased, and central corneal thickness decreased over time. In the animal study, corneal edema was greater in the NaOH group compared to the control at both day 1 and day 7. At day 1, no CECs were detected at the center and periphery of the corneas in the NaOH group. Two weeks after injury, small, hexagonal CECs were detected in peripheral cornea, while CECs in mid-periphery were large and non-hexagonal.CECs migrated from the periphery to the center of the cornea after endothelial injury. The peripheral corneal endothelium may act as a cell resource for the recovery of corneal endothelium.

  6. Corneal endothelial glutathione after photodynamic change

    International Nuclear Information System (INIS)

    Hull, D.S.; Riley, M.V.; Csukas, S.; Green, K.

    1982-01-01

    Rabbit corneal endothelial cells perfused with 5 X 10(-6)M rose bengal and exposed to incandescent light demonstrated no alteration of either total of or percent oxidized glutathione after 1 hr. Addition of 5400 U/ml catalase to the perfusing solution had no effect on total glutathione levels but caused a marked reduction in percent oxidized glutathione in corneas exposed to light as well as in those not exposed to light. Substitution of sucrose for glucose in the perfusing solution had no effect on total or percent oxidized glutathione. Perfusion of rabbit corneal endothelium with 0.5 mM chlorpromazine and exposure to ultraviolet (UV) light resulted in no change in total glutathione content. A marked reduction in percent oxidized glutathione occurred, however, in corneas perfused with 0.5 mM chlorpromazine both in the presence and absence of UV light. It is concluded that photodynamically induced swelling of corneas is not the result of a failure of the glutathione redox system

  7. Corneal endothelial cell density and morphology in healthy Turkish eyes.

    Science.gov (United States)

    Arıcı, Ceyhun; Arslan, Osman Sevki; Dikkaya, Funda

    2014-01-01

    Purpose. To describe the normative values of corneal endothelial cell density, morphology, and central corneal thickness in healthy Turkish eyes. Methods. Specular microscopy was performed in 252 eyes of 126 healthy volunteers (M : F, 42 : 84). Parameters studied included mean endothelial cell density (MCD), mean cell area (MCA), coefficient of variation (CV) in cell size, percentage of hexagonal cells, and central corneal thickness (CCT). Results. The mean age of volunteers was 44.3 ± 13.5 (range, 20 to 70) years. There was a statistically significant decrease in MCD (P Filipino eyes and higher than that described in Indian, Thai, and Iranian eyes.

  8. CORNEAL ENDOTHELIAL CELL DENSITY IN ACUTE ANGLE CLOSURE GLAUCOMA

    Directory of Open Access Journals (Sweden)

    Nishat Sultana K

    2016-09-01

    Full Text Available BACKGROUND Angle closure is characterised by apposition of the peripheral iris against the trabecular meshwork resulting in obstruction of aqueous outflow. Acute angle-closure glaucoma is characterised by pain, redness and blurred vision. The pain is typically a severe deep ache that follows the trigeminal distribution and maybe associated with nausea, vomiting, bradycardia and profuse sweating. The blurred vision, which is typically marked maybe caused by stretching of the corneal lamellae initially and later oedema of the cornea as well as a direct effect of the IOP on the optic nerve head. The modifications in corneal endothelial cell density after a crisis of angle-closure glaucoma is being evaluated. AIMS AND OBJECTIVES The objective of the study is to assess the corneal endothelial cell count (density by specular microscopy in patients presenting with acute angle-closure glaucoma. METHODS Corneal endothelial cell counts of 20 eyes of patients with PACG with an earlier documented symptomatic acute attack unilaterally were compared with 20 fellow eyes. Evaluation of patient included visual acuity, intraocular pressure, gonioscopy, disc findings and specular microscopy. RESULTS The mean endothelial cell density was 2104 cells/mm2 in the eye with acute attack and 2615 cells/mm2 in the fellow eye. The average endothelial cell count when the duration of attack lasted more than 72 hours was 1861 cells/mm2 . CONCLUSION Corneal endothelial cell density was found to be significantly reduced in eyes following an acute attack of primary angle closure glaucoma.

  9. Animal study on transplantation of human umbilical vein endothelial cells for corneal endothelial decompensation

    Directory of Open Access Journals (Sweden)

    Li Cui

    2014-06-01

    Full Text Available AIM: To explore the feasibility of culturing human umbilical vein endothelial cells(HUVECon acellular corneal stroma and performing the posterior lamellar endothelial keratoplasty(PLEKtreating corneal endothelial decompensation.METHODS: Thirty New-Zealand rabbits were divided into three groups randomly, 10 rabbits for experimental group, 10 for stroma group and 10 for control group. Corneal endothelial cells were removed to establish animal model of corneal endothelial failure. PLEK was performed on the rabbits of experimental group and stroma group, and nothing was transplantated onto the rabbits of control group with the deep layer excised only. Postoperative observation was taken for 3mo. The degree of corneal edema and central corneal thickness were recorded for statistical analysis.RESULTS: Corneas in experimental group were relieved in edema obviously compared with that in stroma group and the control group, and showed increased transparency 7d after the operation. The average density of endothelial cells was 2 026.4±129.3cells/mm2, and average central corneal thickness was 505.2±25.4μm in experimental group, while 1 535.6±114.5μm in stroma group and 1 493.5±70.2μm in control group 3mo after operation.CONCLUSION:We achieved preliminary success in our study that culturing HUVEC on acellular corneal stroma and performing PLEK for corneal endothelial decompensation. HUVEC transplanted could survive in vivo, and have normal biological function of keeping cornea transparent. This study provides a new idea and a new way clinically for the treatment of corneal endothelial diseases.

  10. Hormonal regulation of Na+/K+-dependent ATPase activity and pump function in corneal endothelial cells.

    Science.gov (United States)

    Hatou, Shin

    2011-10-01

    Na- and K-dependent ATPase (Na,K-ATPase) in the basolateral membrane of corneal endothelial cells plays an important role in the pump function of the corneal endothelium. We investigated the role of dexamethasone in the regulation of Na,K-ATPase activity and pump function in these cells. Mouse corneal endothelial cells were exposed to dexamethasone or insulin. ATPase activity was evaluated by spectrophotometric measurement, and pump function was measured using an Ussing chamber. Western blotting and immunocytochemistry were performed to measure the expression of the Na,K-ATPase α1-subunit. Dexamethasone increased Na,K-ATPase activity and the pump function of endothelial cells. Western blot analysis indicated that dexamethasone increased the expression of the Na,K-ATPase α1-subunit but decreased the ratio of active to inactive Na,K-ATPase α1-subunit. Insulin increased Na,K-ATPase activity and pump function of cultured corneal endothelial cells. These effects were transient and blocked by protein kinase C inhibitors and inhibitors of protein phosphatases 1 (PP1) and 2A (PP2A). Western blot analysis indicated that insulin decreased the amount of inactive Na,K-ATPase α1-subunit, but the expression of total Na,K-ATPase α1-subunit was unchanged. Immunocytochemistry showed that insulin increased cell surface expression of the Na,K-ATPase α1-subunit. Our results suggest that dexamethasone and insulin stimulate Na,K-ATPase activity in mouse corneal endothelial cells. The effect of dexamethasone activation in these cells was mediated by Na,K-ATPase synthesis and an increased enzymatic activity because of dephosphorylation of Na,K-ATPase α1-subunits. The effect of insulin is mediated by the protein kinase C, PP1, and/or PP2A pathways.

  11. New therapeutic modality for corneal endothelial disease using Rho-associated kinase inhibitor eye drops.

    Science.gov (United States)

    Koizumi, Noriko; Okumura, Naoki; Ueno, Morio; Kinoshita, Shigeru

    2014-11-01

    Corneal endothelial dysfunction accompanied by visual disturbance is a primary indication for corneal endothelial transplantation. However, despite the value and potential of endothelial graft surgery, a strictly pharmacological approach for treating corneal endothelial dysfunction remains an attractive proposition. Previously, we reported that the selective Rho-associated kinase (ROCK) inhibitor Y-27632 promotes cell adhesion and proliferation, and inhibits the apoptosis of primate corneal endothelial cells in culture. These findings have led us to develop a novel medical treatment for the early phase of corneal endothelial disease using ROCK inhibitor eye drops. In rabbit and monkey models of partial endothelial dysfunction, we showed that corneal endothelial wound healing was accelerated via the topical application of ROCK inhibitor to the ocular surface, resulting in the regeneration of a corneal endothelial monolayer with a high endothelial cell density. Based on these animal studies, we are now attempting to advance the clinical application of ROCK inhibitor eye drops for patients with corneal endothelial dysfunction. A pilot clinical study was performed at the Kyoto Prefectural University of Medicine, and the effects of Y-27632 eye drops after transcorneal freezing were evaluated in 8 patients with corneal endothelial dysfunction. We observed a positive effect of ROCK inhibitor eye drops in treating patients with central edema caused by Fuchs corneal endothelial dystrophy. We believe that our new findings will contribute to the establishment of a new approach for the treatment of corneal endothelial dysfunction.

  12. Successful transplantation of in vitro expanded human corneal endothelial precursors to corneal endothelial surface using a nanocomposite sheet

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2011-01-01

    Full Text Available Background: Though the transplantation of in vitro expanded human corneal endothelial precursors in animal models of endothelial damage by injecting into the anterior chamber has been reported, the practical difficulties of accomplishing such procedure in human patients have been a hurdle to clinical translation. Here we report the successful transplantation of in vitro expanded human corneal precursor cells to an animal eye using a transparent Nano-composite sheet and their engraftment.Materials and Methods: Human Corneal endothelial cells (HCEC were isolated from human cadaver eyes with informed consent and expanded in the lab using a sphere forming assay in a novel Thermoreversible Gelation Polymer (TGP for 26 days. HCEC obtained by sphere forming assay were seeded in a novel Nano-composite sheet, which was made of PNIPA-NC gels by in-situ, free-radical polymerization of NIPA monomer in the presence of exfoliated clay (synthetic hectorite “Laponite XLG” uniformly dispersed in aqueous media. After a further seven days in vitro culture of HCEC in the Nano-composite sheet, cells were harvested and transplanted on cadaver-bovine eyes (n=3. The cells were injected between the corneal endothelial layer and the Nano-composite sheet that had been placed prior to the injection in close proximity to the endothelial layer. After three hours, the transplanted Nano-composite sheets were removed from the bovine eyes and subjected to microscopic examination. The corneas were subjected to Histo-pathological studies along with controls. Results: HCEC formed sphere like colonies in TGP which expressed relevant markers as confirmed by RT-PCR. Microscopic studies of the Nanosheets and histopathological studies of the cornea of the Bull’s eye revealed that the HCEC got engrafted to the corneal endothelial layer of the bovine eyes with no remnant cells in the Nanosheet. Conclusion: Transplantation of in vitro expanded donor human corneal endothelial cells

  13. Applications of Biomaterials in Corneal Endothelial Tissue Engineering.

    Science.gov (United States)

    Wang, Tsung-Jen; Wang, I-Jong; Hu, Fung-Rong; Young, Tai-Horng

    2016-11-01

    When corneal endothelial cells (CECs) are diseased or injured, corneal endothelium can be surgically removed and tissue from a deceased donor can replace the original endothelium. Recent major innovations in corneal endothelial transplantation include replacement of diseased corneal endothelium with a thin lamellar posterior donor comprising a tissue-engineered endothelium carried or cultured on a thin substratum with an organized monolayer of cells. Repairing CECs is challenging because they have restricted proliferative ability in vivo. CECs can be cultivated in vitro and seeded successfully onto natural tissue materials or synthetic polymeric materials as grafts for transplantation. The optimal biomaterials for substrata of CEC growth are being investigated. Establishing a CEC culture system by tissue engineering might require multiple biomaterials to create a new scaffold that overcomes the disadvantages of single biomaterials. Chitosan and polycaprolactone are biodegradable biomaterials approved by the Food and Drug Administration that have superior biological, degradable, and mechanical properties for culturing substratum. We successfully hybridized chitosan and polycaprolactone into blended membranes, and demonstrated that CECs proliferated, developed normal morphology, and maintained their physiological phenotypes. The interaction between cells and biomaterials is important in tissue engineering of CECs. We are still optimizing culture methods for the maintenance and differentiation of CECs on biomaterials.

  14. Corneal Endothelial Cell Density and Morphology in Healthy Turkish Eyes

    Directory of Open Access Journals (Sweden)

    Ceyhun Arıcı

    2014-01-01

    Full Text Available Purpose. To describe the normative values of corneal endothelial cell density, morphology, and central corneal thickness in healthy Turkish eyes. Methods. Specular microscopy was performed in 252 eyes of 126 healthy volunteers (M : F, 42 : 84. Parameters studied included mean endothelial cell density (MCD, mean cell area (MCA, coefficient of variation (CV in cell size, percentage of hexagonal cells, and central corneal thickness (CCT. Results. The mean age of volunteers was 44.3±13.5 (range, 20 to 70 years. There was a statistically significant decrease in MCD (P<0.001; correlation, −0.388 and percentage of hexagonal cells, (P<0.001; correlation, −0.199 with age. There was also a statistically significant increase in MCA (P<0.001; correlation, 0.363 with increasing age. There was no statistically significant difference in MCD, MCA, CV in cell size, percentage of hexagonal cells, and CCT between genders and there was also no significant difference in these parameters between fellow eyes of subjects. Conclusions. Normotive data for the endothelium in the Turkish population are reported. Endothelial cell density in the Turkish eyes is less than that described in the Japanese, American, Chinese, and Filipino eyes and higher than that described in Indian, Thai, and Iranian eyes.

  15. CD147 required for corneal endothelial lactate transport.

    Science.gov (United States)

    Li, Shimin; Nguyen, Tracy T; Bonanno, Joseph A

    2014-06-26

    CD147/basigin is a chaperone for lactate:H(+) cotransporters (monocarboxylate transporters) MCT1 and MCT4. We tested the hypothesis that MCT1 and -4 in corneal endothelium contribute to lactate efflux from stroma to anterior chamber and that silencing CD147 expression would cause corneal edema. CD147 was silenced via small interfering ribonucleic acid (siRNA) transfection of rabbit corneas ex vivo and anterior chamber lenti-small hairpin RNA (shRNA) pseudovirus in vivo. CD147 and MCT expression was examined by Western blot, RT-PCR, and immunofluorescence. Functional effects were examined by measuring lactate-induced cell acidification, corneal lactate efflux, [lactate], central cornea thickness (CCT), and Azopt (a carbonic anhydrase inhibitor) sensitivity. In ex vivo corneas, 100 nM CD147 siRNA reduced CD147, MCT1, and MCT4 expression by 85%, 79%, and 73%, respectively, while MCT2 expression was unaffected. CD147 siRNA decreased lactate efflux from 3.9 ± 0.81 to 1.5 ± 0.37 nmol/min, increased corneal [lactate] from 19.28 ± 7.15 to 56.73 ± 8.97 nmol/mg, acidified endothelial cells (pHi = 6.83 ± 0.07 vs. 7.19 ± 0.09 in control), and slowed basolateral lactate-induced acidification from 0.0034 ± 0.0005 to 0.0012 ± 0.0005 pH/s, whereas apical acidification was unchanged. In vivo, CD147 shRNA increased CCT by 28.1 ± 0.9 μm at 28 days; Azopt increased CCT to 24.4 ± 3.12 vs. 12.0 ± 0.48 μm in control, and corneal [lactate] was 47.63 ± 6.29 nmol/mg in shCD147 corneas and 17.82 ± 4.93 nmol/mg in paired controls. CD147 is required for the expression of MCT1 and MCT4 in the corneal endothelium. Silencing CD147 slows lactate efflux, resulting in stromal lactate accumulation and corneal edema, consistent with lactate efflux as a significant component of the corneal endothelial pump. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  16. Research on mouse model of grade II corneal alkali burn

    Directory of Open Access Journals (Sweden)

    Jun-Qiang Bai

    2016-04-01

    Full Text Available AIM: To choose appropriate concentration of sodium hydroxide (NaOH solution to establish a stable and consistent corneal alkali burn mouse model in grade II. METHODS: The mice (n=60 were randomly divided into four groups and 15 mice each group. Corneal alkali burns were induced by placing circle filter paper soaked with NaOH solutions on the right central cornea for 30s. The concentrations of NaOH solutions of groups A, B, C, and D were 0.1 mol/L, 0.15 mol/L , 0.2 mol/L, and 1.0 mol/L respectively. Then these corneas were irrigated with 20 mL physiological saline (0.9% NaCl. On day 7 postburn, slit lamp microscope was used to observe corneal opacity, corneal epithelial sodium fluorescein staining positive rate, incidence of corneal ulcer and corneal neovascularization, meanwhile pictures of the anterior eyes were taken. Cirrus spectral domain optical coherence tomography was used to scan cornea to observe corneal epithelial defect and corneal ulcer. RESULTS: Corneal opacity scores ( were not significantly different between the group A and group B (P=0.097. Incidence of corneal ulcer in group B was significantly higher than that in group A (P=0.035. Incidence of corneal ulcer and perforation rate in group B was lower than that in group C. Group C and D had corneal neovascularization, and incidence of corneal neovascularization in group D was significantly higher than that in group C (P=0.000. CONCLUSION: Using 0.15 mol/L NaOH can establish grade II mouse model of corneal alkali burns.

  17. Validation of Na,K-ATPase pump function of corneal endothelial cells for corneal regenerative medicine.

    Science.gov (United States)

    Hatou, Shin; Higa, Kazunari; Inagaki, Emi; Yoshida, Satoru; Kimura, Erika; Hayashi, Ryuhei; Tsujikawa, Motokazu; Tsubota, Kazuo; Nishida, Kohji; Shimmura, Shigeto

    2013-12-01

    Tissue-engineering approaches to cultivate corneal endothelial cells (CECs) or induce CECs from stem cells are under investigation for the treatment of endothelial dysfunction. Before clinical application, a validation method to determine the quality of these cells is required. In this study, we quantified the endothelial pump function required for maintaining the corneal thickness using rabbit CECs (RCECs) and a human CEC line (B4G12). The potential difference of RCECs cultured on a permeable polyester membrane (Snapwell), B4G12 cells on Snapwell, or B4G12 cells on a collagen membrane (CM6) was measured by an Ussing chamber system, and the effect of different concentrations of ouabain (Na,K-ATPase specific inhibitor) was obtained. A mathematical equation derived from the concentration curve revealed that 2 mM ouabain decreases pump function of RCECs to 1.0 mV, and 0.6 mM ouabain decreases pump function of B4G12 on CM6 to 1.0 mV. Ouabain injection into the anterior chamber of rabbit eyes at a concentration of pump function >1.0 mV is required to maintain the corneal thickness. These results can be used for standardization of CEC pump function and validation of tissue-engineered CEC sheets for clinical use.

  18. Corneal endothelial cell density and morphology in Phramongkutklao Hospital

    Directory of Open Access Journals (Sweden)

    Narumon Sopapornamorn

    2008-03-01

    Full Text Available Narumon Sopapornamorn1, Manapon Lekskul1, Suthee Panichkul21Department of Ophthalmology, Phramongkutklao Hospital, Bangkok, Thailand; 2Department of Obstetrics and Gynecology, Phramongkutklao College of Medicine, Bangkok, ThailandObjective: To describe the corneal endothelial density and morphology in patients of Phramongkutklao Hospital and the relationship between endothelial cell parameters and other factors.Methods: Four hundred and four eyes of 202 volunteers were included. Noncontact specular microscopy was performed after taking a history and testing the visual acuity, intraocular pressure measurement, Schirmer’s test and routine eye examination by slit lamp microscope. The studied parameters included mean endothelial cell density (MCD, coefficient of variation (CV, and percentage of hexagonality.Results: The mean age of volunteers was 45.73 years; the range being 20 to 80 years old. Their MCD (SD, mean percentage of CV (SD and mean (SD percentage of hexagonality were 2623.49(325 cell/mm2, 39.43(8.23% and 51.50(10.99%, respectively. Statistically, MCD decreased significantly with age (p < 0.01. There was a significant difference in the percentage of CV between genders. There was no statistical significance between parameters and other factors.Conclusion: The normative data of the corneal endothelium of Thai eyes indicated that, statistically, MCD decreased significantly with age. Previous studies have reported no difference in MCD, percentage of CV, and percentage of hexagonality between gender. Nevertheless, significantly different percentages of CV between genders were presented in this study.Keywords: Corneal endothelial cell, parameters, age, gender, smoking, Thailand

  19. [Influence AquaLase at corneal endothelial cells].

    Science.gov (United States)

    Jirásková, N; Rozsíval, P; Ludvíková, M; Burova, M; Nekolová, J

    2009-07-01

    To assess the effect of the cleaning of the posterior capsule using pulses of balanced salt solution (BSS) on the corneal endothelial cells. This pilot study involves 43 patients with bilateral cataracts having lens removal using torsional phacoemulsification (Ozil, Infiniti, Alcon) and bimanul irrigation/aspiration (I/A). Posterior capsule of the right eye of each patient was cleaned using pulses of BSS (AquaLase, Infiniti, Alcon). Surgery was performed by one of 2 surgeons (NJ, PR), both eyes of each patient was operated on by the same surgeon. Best corrected visual acuity (BCVA), endotelial cell count and pachymetry were evaluated pre- and postoperatively as well as occurence af peri- and postoperative complications. Preoperative mean pachymetry (P) was 566 +/- 45 microm in the right eye (RE) and 562 +/- 42 microm in the left eye (LE), mean endotelial cell count (ECC) 2541 +/- 317 cells/mm2 (RE) and 2567 +/- 311 cells/mm2 (LE). Three months after surgery P was 557 +/- 43 microm (RE) and 558 +/- 45 microm (LE) and ECC 2368 +/- 416 cells/mm2 (RE) and 2396 +/- 417 cells/mm2 (LE). There was no statistical difference in postoperative changes of both corneal parameters between right and left eyes. Best corrected visual acuity improved in all eyes and no peri-or postoperative complications occured. Cleaning of the posterior capsule using AquaLase is safe for corneal endothelial cells.

  20. Corneal Endothelial Safety of Intracameral Preservative-free 1% Xylocaine

    Directory of Open Access Journals (Sweden)

    Shah Alpesh

    2004-01-01

    Full Text Available Purpose : To evaluate the effect of intracameral preservative-free 1% xylocaine on the corneal endothelium as an adjuvant to topical anaesthesia during phacoemulsification and Acrysof foldable IOL implantation. Material & Methods: This is a prospective, controlled, randomised, double-masked study. 106 patients with soft to moderately dense (Grade 1-3 senile cataract and corneal endothelial cell density of >1500/mm2 were randomised to the xylocaine group (n=53 and control group(n=53. Central endothelial specular microscopy and ultrasound corneal pachymetry were performed preoperatively. On the first postoperative day the eyes were evaluated for corneal oedema and Descemet′s folds. Ultrasound corneal pachymetry was performed at 1, 3 and 12 months. Specular microscopy was performed at 3 and 12 months. Cell loss was expressed as a percentage of preoperative cell density. Six patients could not complete one year follow-up. Chi-square and paired t test (2 tail statistical tests were applied for analysis. Results: Four (7.54% patients in the xylocaine group and 5 (9.43% in the control group had a few Descemet′s folds associated with mild central stromal oedema. Corneal thickness increased from 549.3µ ± 37.2µ to 555.5µ ± 36.5µ in the xylocaine group and from 553.1µ ± 36.2µ to 559.3µ ± 40.5µ in the control group at the one-month postoperative visit. Thickness returned to the preoperative level in xylocaine group 549.6µ ± 34.5µ and control group 554.7µ ± 41.1µ at three months. (P=0.484 The percentage of cell loss was 4.47 ± 2.53% in the xylocaine group and 4.49 ± 3.09 % in the control group at one year. (P=0.97 Conclusion: Intracameral preservative-free 1% xylocaine does not appear to affect corneal endothelium adversely during phacoemulsification.

  1. Discovery of molecular markers to discriminate corneal endothelial cells in the human body

    NARCIS (Netherlands)

    Yoshihara, Masahito; Ohmiya, Hiroko; Hara, Susumu; Kawasaki, Satoshi; Hayashizaki, Yoshihide; Itoh, Masayoshi; Kawaji, Hideya; Tsujikawa, Motokazu; Nishida, Kohji; Clevers, J.C.; van de Wetering, M.L.

    2015-01-01

    The corneal endothelium is a monolayer of hexagonal corneal endothelial cells (CECs) on the inner surface of the cornea. CECs are critical in maintaining corneal transparency through their barrier and pump functions. CECs in vivo have a limited capacity in proliferation, and loss of a significant

  2. Discovery of Molecular Markers to Discriminate Corneal Endothelial Cells in the Human Body

    NARCIS (Netherlands)

    Yoshihara, Masahito; Ohmiya, Hiroko; Hara, Susumu; Kawasaki, Satoshi; Hayashizaki, Yoshihide; Itoh, Masayoshi; Kawaji, Hideya; Tsujikawa, Motokazu; Nishida, Kohji; Forrest, Alistair R. R.; Rehli, Michael; Baillie, J. Kenneth; de Hoon, Michiel J. L.; Haberle, Vanja; Lassmann, Timo; Kulakovskiy, Ivan V.; Lizio, Marina; Andersson, Robin; Mungall, Christopher J.; Meehan, Terrence F.; Schmeier, Sebastian; Bertin, Nicolas; Jørgensen, Mette; Dimont, Emmanuel; Arner, Erik; Schmidl, Christian; Schaefer, Ulf; Medvedeva, Yulia A.; Plessy, Charles; Vitezic, Morana; Severin, Jessica; Semple, Colin A.; Ishizu, Yuri; Francescatto, Margherita; Alam, Intikhab; Albanese, Davide; Altschuler, Gabriel M.; Archer, John A. C.; Arner, Peter; Babina, Magda; Baker, Sarah; Balwierz, Piotr J.; Beckhouse, Anthony G.; Pradhan-Bhatt, Swati; Blake, Judith A.; Blumenthal, Antje; Bodega, Beatrice; Bonetti, Alessandro; Briggs, James; Geijtenbeek, Teunis B.

    2015-01-01

    The corneal endothelium is a monolayer of hexagonal corneal endothelial cells (CECs) on the inner surface of the cornea. CECs are critical in maintaining corneal transparency through their barrier and pump functions. CECs in vivo have a limited capacity in proliferation, and loss of a significant

  3. Corneal endothelial cell density and morphology in patients with acromegaly.

    Science.gov (United States)

    Hatipoglu, Esra; Arici, Ceyhun; Arslan, Osman Sevki; Dikkaya, Funda; Sultan, Pinar; Kadioglu, Pinar; Gundogdu, Sadi

    2014-12-01

    Acromegaly has various impacts on many organs. The ophthalmologic effects of acromegaly have not yet been investigated in detail. The aim of the current study was to evaluate qualitative and quantitative changes in corneal endothelial cells and central corneal thickness (CCT) of the patients with acromegaly. In this prospective, cross-sectional study, 128 eyes of 64 patients with acromegaly (female/male=40/24) and 208 eyes of 104 age and gender-matched healthy volunteers (female/male=69/35) were included. Endothelial cell density (ECD), cellular area (CA), coefficient of variation (CV) in cell size, percentage of hexagonal cells, and CCT were measured in patients with acromegaly and in healthy volunteers using the noncontact specular microscopy (SP-3000P: Topcon Corporation, Tokyo, Japan). ECD and CA were lower in cases with acromegaly than in controls (ECD in acromegaly: 2615.65 cell/mm(2) and in controls: 2700.35 cell/mm(2); p=0.002. CA in acromegaly: 382.30μm(2) and in controls: 400.30μm(2); p=0.02). In the entire group with acromegaly, the time elapsed since diagnosis was positively correlated with CA and was negatively correlated with ECD (r=+0.39, p=0.001 and r=-0.42, p=0.001). The endothelial layer of the cornea may be under risk of impairment with prolonged disease duration in acromegaly. Consistency of the corneal endothelium should be also sought during long-term follow-up of the cases with acromegaly. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Role of insulin in regulation of Na+-/K+-dependent ATPase activity and pump function in corneal endothelial cells.

    Science.gov (United States)

    Hatou, Shin; Yamada, Masakazu; Akune, Yoko; Mochizuki, Hiroshi; Shiraishi, Atsushi; Joko, Takeshi; Nishida, Teruo; Tsubota, Kazuo

    2010-08-01

    The Na(+)-/K(+)-dependent ATPase (Na,K-ATPase) expressed in the basolateral membrane of corneal endothelial cells plays an important role in the pump function of the corneal endothelium. The role of insulin in the regulation of Na,K-ATPase activity and pump function in corneal endothelial cells was investigated. Confluent monolayers of mouse corneal endothelial cells were exposed to insulin. ATPase activity was evaluated by spectrophotometric measurement of phosphate released from ATP with the use of ammonium molybdate; Na,K-ATPase activity was defined as the portion of total ATPase activity sensitive to ouabain. Pump function was measured with the use of a Ussing chamber; pump function attributable to Na,K-ATPase activity was defined as the portion of the total short-circuit current sensitive to ouabain. Western blot analysis and immunocytochemistry were performed to measure the expression of the Na,K-ATPase alpha(1)-subunit. Insulin increased the Na,K-ATPase activity and pump function of cultured corneal endothelial cells. These effects were blocked by protein kinase C (PKC) inhibitors and protein phosphatases 1 and 2A inhibitor. Western blot analysis indicated that insulin decreased the ratio of the inactive Na,K-ATPase alpha(1)-subunit. Immunocytochemistry indicated that insulin increased the cell surface expression of the Na,K-ATPase alpha(1)-subunit. These results suggest that insulin increases the Na,K-ATPase activity and pump function of cultured corneal endothelial cells. The effect of insulin is mediated by PKC and presumably results in the activation of PP1, 2A, or both, which are essential for activating Na,K-ATPase by alpha(1)-subunit dephosphorylation.

  5. Corneal endothelial cell changes associated with cataract surgery in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Hugod, Mikkel; Storr-Paulsen, Allan; Norregaard, Jens Christian

    2011-01-01

    To investigate the corneal endothelial cell density and morphology in patients with and without diabetes after phacoemulsification with intraocular lens implantation.......To investigate the corneal endothelial cell density and morphology in patients with and without diabetes after phacoemulsification with intraocular lens implantation....

  6. Efficient Generation of Human Embryonic Stem Cell-Derived Corneal Endothelial Cells by Directed Differentiation.

    Directory of Open Access Journals (Sweden)

    Kathryn L McCabe

    Full Text Available To generate human embryonic stem cell derived corneal endothelial cells (hESC-CECs for transplantation in patients with corneal endothelial dystrophies.Feeder-free hESC-CECs were generated by a directed differentiation protocol. hESC-CECs were characterized by morphology, expression of corneal endothelial markers, and microarray analysis of gene expression.hESC-CECs were nearly identical morphologically to primary human corneal endothelial cells, expressed Zona Occludens 1 (ZO-1 and Na+/K+ATPaseα1 (ATPA1 on the apical surface in monolayer culture, and produced the key proteins of Descemet's membrane, Collagen VIIIα1 and VIIIα2 (COL8A1 and 8A2. Quantitative PCR analysis revealed expression of all corneal endothelial pump transcripts. hESC-CECs were 96% similar to primary human adult CECs by microarray analysis.hESC-CECs are morphologically similar, express corneal endothelial cell markers and express a nearly identical complement of genes compared to human adult corneal endothelial cells. hESC-CECs may be a suitable alternative to donor-derived corneal endothelium.

  7. The effects of dexamethasone on the Na,K-ATPase activity and pump function of corneal endothelial cells.

    Science.gov (United States)

    Hatou, Shin; Yamada, Masakazu; Mochizuki, Hiroshi; Shiraishi, Atsushi; Joko, Takeshi; Nishida, Teruo

    2009-05-01

    The Na(+)- and K(+)-dependent ATPase (Na,K-ATPase) expressed in the basolateral membrane of corneal endothelial cells plays an important role in the pump function of the corneal endothelium. We investigated the possible role of dexamethasone in the regulation of Na,K-ATPase activity and pump function in corneal endothelial cells. Confluent monolayers of mouse corneal endothelial cells were exposed to dexamethasone. ATPase activity of the cells was evaluated by spectrophotometric measurement of phosphate released from ATP with the use of ammonium molybdate, with Na,K-ATPase activity being defined as the portion of total ATPase activity sensitive to ouabain. Pump function of the cells was measured with the use of an Ussing chamber, with the pump function attributable to Na,K-ATPase activity being defined as the portion of the total short-circuit current sensitive to ouabain. Western blot analysis was examined to measure the expression of the Na,K-ATPase alpha(1)-subunit. Dexamethasone (1 or 10 microM) increased the Na,K-ATPase activity and pump function of the cultured cells. These effects of dexamethasone were blocked by cycloheximide, a protein synthesis inhibitor. Western blot analysis also indicated that dexamethasone increased the expression of the Na,K-ATPase alpha(1)-subunit, whereas it decreased the expression of the phospho-Na,K-ATPase alpha(1)-subunit. Our results suggest that dexamethasone stimulates Na,K-ATPase activity in mouse corneal endothelial cells. The effect of dexamethasone activation in these cells is mediated by Na,K-ATPase synthesis and increase in an enzymatic activity by dephosphorylation of Na,K-ATPase alpha(1)-subunits.

  8. Effects of vitrectomy combined with cataract surgery on the corneal endothelial cells in diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Lei Zhan

    2017-08-01

    Full Text Available AIM: To investigate the effects of vitrectomy combined with cataract surgery on the corneal endothelial cells in diabetic retinopathy. METHODS: A retrospective study was designed. 160 patients(160 eyeswith diabetic retinopathy from Jan 2015 to Feb 2017 were divided into two groups according to cataract. 74 patients(74 eyeswere operated on vitrectomy, and 86 patients(86 eyeson vitrectomy combined with phacoemulsification cataract surgery and capsular bag implantation of foldable intraocular lens. To record the change of corneal endothelial cells density, average cellular area, coefficient of variation and percentage of hexagonal endothelial cell before and after treatment with Topcon corneal specular microscope. RESULTS: Before and after surgery, the results of corneal endothelial cells density, average cellular area, coefficient of variation and percentage of hexagonal endothelial cell in simple vitrectomy group were no significant difference(P>0.05; After treatment corneal endothelial cells density and percentage of hexagonal endothelial cell were changed with statistical difference as the same as average cellular area and coefficient of variation(PPCONCLUSION: It has certain influence on the corned endothelial cells when using vitrectomy combined with cataract surgery in diabetic retinopathy. For patients with indications, it should be paid attention to protecting the corneal endothelial cells.

  9. Cornea stress test--evaluation of corneal endothelial function in vivo by contact lens induced stress

    Directory of Open Access Journals (Sweden)

    Saini Jagjit

    1997-01-01

    Full Text Available Reliable and valid assessment of corneal endothelial function is a critical input for diagnosing, prognosticating and monitoring progression of disorders affecting corneal endothelium. In 123 eyes, corneal endothelial function was assessed employing data from the corneal hydration recovery dynamics. Serial pachometric readings were recorded on Haag-Striet pachometer with Mishima-Hedbys modification before and after two hours of thick soft contact lens wear. Percentage Recovery Per Hour (PRPH was derived from raw data as an index of endothelial function. Assessed PRPH in pseudophakic corneal oedema and Fuchs′ endothelial dystrophy eyes (35.9 +/- 9.8% was significantly lower than normal controls (61.9 +/- 10.5%. On employing receiver operation characteristics curve analysis the tested results demonstrated high sensitivity (87% and specificity (92% for detection of low endothelial function at PRPH cut off of 47.5%. Using this PRPH cut off, 80% of Fuchs′ endothelial dystrophy and 93.3% of pseudophakic corneal oedema eyes could be demonstrated to have low endothelial function. A total of 66.7% of diabetic eyes also demonstrated PRPH of lower than 47.5%. Clear corneal grafts demonstrated PRPH values of 24.6% to 73.0%. Of 6 corneal grafts that demonstrated initial PRPH of lower than 47.5%, 4 failed within 4 to 6 months. Our data demonstrated high sensitivity and specificity of this corneal stress test. PRPH index was useful in quantifying endothelial function in clinical disorders including diabetes mellitus. The index PRPH was demonstrated to be useful in monitoring and prognosticating outcome of corneal grafts.

  10. Corneal endothelial cell density and morphology in normal Iranian eyes

    Directory of Open Access Journals (Sweden)

    Fallah Mohammad

    2006-03-01

    Full Text Available Abstract Background We describe corneal endothelial cell density and morphology in normal Iranian eyes and compare endothelial cell characteristics in the Iranian population with data available in the literature for American and Indian populations. Methods Specular microscopy was performed in 525 eyes of normal Iranian people aged 20 to 85 years old. The studied parameters including mean endothelial cell density (MCD, mean cell area (MCA and coefficient of variation (CV in cell area were analyzed in all of the 525 eyes. Results MCD was 1961 ± 457 cell/mm2 and MCA was 537.0 ± 137.4 μm2. There was no statistically significant difference in MCD, MCA and CV between genders (Student t-test, P = 0.85, P = 0.97 and P = 0.15 respectively. There was a statistically significant decrease in MCD with age (P r = -0.64. The rate of cell loss was 0.6% per year. There was also a statistically significant increase in MCA (P r = 0.56 and CV (P r = 0.30 from 20 to 85 years of age. Conclusion The first normative data for the endothelium of Iranian eyes seems to confirm that there are no differences in MCD, MCA and CV between genders. Nevertheless, the values obtained in Iranian eyes seem to be different to those reported by the literature in Indian and American populations.

  11. A fully automated cell segmentation and morphometric parameter system for quantifying corneal endothelial cell morphology.

    Science.gov (United States)

    Al-Fahdawi, Shumoos; Qahwaji, Rami; Al-Waisy, Alaa S; Ipson, Stanley; Ferdousi, Maryam; Malik, Rayaz A; Brahma, Arun

    2018-07-01

    Corneal endothelial cell abnormalities may be associated with a number of corneal and systemic diseases. Damage to the endothelial cells can significantly affect corneal transparency by altering hydration of the corneal stroma, which can lead to irreversible endothelial cell pathology requiring corneal transplantation. To date, quantitative analysis of endothelial cell abnormalities has been manually performed by ophthalmologists using time consuming and highly subjective semi-automatic tools, which require an operator interaction. We developed and applied a fully-automated and real-time system, termed the Corneal Endothelium Analysis System (CEAS) for the segmentation and computation of endothelial cells in images of the human cornea obtained by in vivo corneal confocal microscopy. First, a Fast Fourier Transform (FFT) Band-pass filter is applied to reduce noise and enhance the image quality to make the cells more visible. Secondly, endothelial cell boundaries are detected using watershed transformations and Voronoi tessellations to accurately quantify the morphological parameters of the human corneal endothelial cells. The performance of the automated segmentation system was tested against manually traced ground-truth images based on a database consisting of 40 corneal confocal endothelial cell images in terms of segmentation accuracy and obtained clinical features. In addition, the robustness and efficiency of the proposed CEAS system were compared with manually obtained cell densities using a separate database of 40 images from controls (n = 11), obese subjects (n = 16) and patients with diabetes (n = 13). The Pearson correlation coefficient between automated and manual endothelial cell densities is 0.9 (p system, and the possibility of utilizing it in a real world clinical setting to enable rapid diagnosis and for patient follow-up, with an execution time of only 6 seconds per image. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Development of Cell Analysis Software for Cultivated Corneal Endothelial Cells.

    Science.gov (United States)

    Okumura, Naoki; Ishida, Naoya; Kakutani, Kazuya; Hongo, Akane; Hiwa, Satoru; Hiroyasu, Tomoyuki; Koizumi, Noriko

    2017-11-01

    To develop analysis software for cultured human corneal endothelial cells (HCECs). Software was designed to recognize cell borders and to provide parameters such as cell density, coefficient of variation, and polygonality of cultured HCECs based on phase contrast images. Cultured HCECs with high or low cell density were incubated with Ca-free and Mg-free phosphate-buffered saline for 10 minutes to reveal the cell borders and were then analyzed with software (n = 50). Phase contrast images showed that cell borders were not distinctly outlined, but these borders became more distinctly outlined after phosphate-buffered saline treatment and were recognized by cell analysis software. The cell density value provided by software was similar to that obtained using manual cell counting by an experienced researcher. Morphometric parameters, such as the coefficient of variation and polygonality, were also produced by software, and these values were significantly correlated with cell density (Pearson correlation coefficients -0.62 and 0.63, respectively). The software described here provides morphometric information from phase contrast images, and it enables subjective and noninvasive quality assessment for tissue engineering therapy of the corneal endothelium.

  13. Human Bone Derived Collagen for the Development of an Artificial Corneal Endothelial Graft. In Vivo Results in a Rabbit Model.

    Directory of Open Access Journals (Sweden)

    Natalia Vázquez

    Full Text Available Corneal keratoplasty (penetrating or lamellar using cadaveric human tissue, is nowadays the main treatment for corneal endotelial dysfunctions. However, there is a worldwide shortage of donor corneas available for transplantation and about 53% of the world's population have no access to corneal transplantation. Generating a complete cornea by tissue engineering is still a tough goal, but an endothelial lamellar graft might be an easier task. In this study, we developed a tissue engineered corneal endothelium by culturing human corneal endothelial cells on a human purified type I collagen membrane. Human corneal endothelial cells were cultured from corneal rims after corneal penetrating keratoplasty and type I collagen was isolated from remnant cancellous bone chips. Isolated type I collagen was analyzed by western blot, liquid chromatography -mass spectrometry and quantified using the exponentially modified protein abundance index. Later on, collagen solution was casted at room temperature obtaining an optically transparent and mechanically manageable membrane that supports the growth of human and rabbit corneal endothelial cells which expressed characteristic markers of corneal endothelium: zonula ocluddens-1 and Na+/K+ ATPase. To evaluate the therapeutic efficiency of our artificial endothelial grafts, human purified type I collagen membranes cultured with rabbit corneal endothelial cells were transplanted in New Zealand white rabbits that were kept under a minimal immunosuppression regimen. Transplanted corneas maintained transparency for as long as 6 weeks without obvious edema or immune rejection and maintaining the same endothelial markers that in a healthy cornea. In conclusion, it is possible to develop an artificial human corneal endothelial graft using remnant tissues that are not employed in transplant procedures. This artificial endothelial graft can restore the integrality of corneal endothelium in an experimental model of

  14. [Analysis of the Effect of Non-phacoemulsification Cataract Operation on Corneal Endothelial Cell Nucleus Division].

    Science.gov (United States)

    Huang, Zufeng; Miao, Xiaoqing

    2015-09-01

    To investigate the effect of non-phacoemulsification cataract operation in two different patterns of nucleus delivery on the quantity and morphology of corneal endothelial cells and postoperative visual acuity. Forty patients diagnosed with cataract underwent cataract surgery and were assigned into the direct nuclear delivery and semi-nuclear delivery groups. Lens density was measured and divided into the hard and soft lenses according to Emery-little lens nucleus grading system. Non-phacoemulsification cataract operation was performed. At 3 d after surgery, the quantity and morphology of corneal endothelium were counted and observed under corneal endothelial microscope. During 3-month postoperative follow-up, the endothelial cell loss rate, morphological changes and visual acuity were compared among four groups. Corneal endothelial cell loss rate in the direct delivery of hard nucleus group significantly differed from those in the other three groups before and 3 months after operation (P nucleus, semi-delivery of hard nucleus and semi-delivery soft nucleus groups (all P > 0.05). Preoperative and postoperative 2-d visual acuity did not differ between the semi-delivery of hard nucleus and direct delivery of soft nucleus groups (P = 0.49), significantly differed from those in the semi-delivery of soft nucleus (P = 0.03) and direct delivery of hard nucleus groups (P = 0.14). Visual acuity at postoperative four months did not differ among four groups (P = 0.067). During non-phacoemulsification cataract surgery, direct delivery of hard nucleus caused severe injury to corneal endothelium and semi-delivery of soft nucleus yielded mild corneal endothelial injury. Slight corneal endothelial injury exerted no apparent effect upon visual acuity and corneal endothelial morphology at three months after surgery.

  15. N-Isopropylacrylamide-co-glycidylmethacrylate as a Thermoresponsive Substrate for Corneal Endothelial Cell Sheet Engineering

    Directory of Open Access Journals (Sweden)

    Bernadette K. Madathil

    2014-01-01

    Full Text Available Endothelial keratoplasty is a recent shift in the surgical treatment of corneal endothelial dystrophies, where the dysfunctional endothelium is replaced whilst retaining the unaffected corneal layers. To overcome the limitation of donor corneal shortage, alternative use of tissue engineered constructs is being researched. Tissue constructs with intact extracellular matrix are generated using stimuli responsive polymers. In this study we evaluated the feasibility of using the thermoresponsive poly(N-isopropylacrylamide-co-glycidylmethacrylate polymer as a culture surface to harvest viable corneal endothelial cell sheets. Incubation below the lower critical solution temperature of the polymer allowed the detachment of the intact endothelial cell sheet. Phase contrast and scanning electron microscopy revealed the intact architecture, cobble stone morphology, and cell-to-cell contact in the retrieved cell sheet. Strong extracellular matrix deposition was also observed. The RT-PCR analysis confirmed functionally active endothelial cells in the cell sheet as evidenced by the positive expression of aquaporin 1, collagen IV, Na+-K+ ATPase, and FLK-1. Na+-K+ ATPase protein expression was also visualized by immunofluorescence staining. These results suggest that the in-house developed thermoresponsive culture dish is a suitable substrate for the generation of intact corneal endothelial cell sheet towards transplantation for endothelial keratoplasty.

  16. Investigation of Overrun-Processed Porous Hyaluronic Acid Carriers in Corneal Endothelial Tissue Engineering.

    Directory of Open Access Journals (Sweden)

    Jui-Yang Lai

    Full Text Available Hyaluronic acid (HA is a linear polysaccharide naturally found in the eye and therefore is one of the most promising biomaterials for corneal endothelial regenerative medicine. This study reports, for the first time, the development of overrun-processed porous HA hydrogels for corneal endothelial cell (CEC sheet transplantation and tissue engineering applications. The hydrogel carriers were characterized to examine their structures and functions. Evaluations of carbodiimide cross-linked air-dried and freeze-dried HA samples were conducted simultaneously for comparison. The results indicated that during the fabrication of freeze-dried HA discs, a technique of introducing gas bubbles in the aqueous biopolymer solutions can be used to enlarge pore structure and prevent dense surface skin formation. Among all the groups studied, the overrun-processed porous HA carriers show the greatest biological stability, the highest freezable water content and glucose permeability, and the minimized adverse effects on ionic pump function of rabbit CECs. After transfer and attachment of bioengineered CEC sheets to the overrun-processed HA hydrogel carriers, the therapeutic efficacy of cell/biopolymer constructs was tested using a rabbit model with corneal endothelial dysfunction. Clinical observations including slit-lamp biomicroscopy, specular microscopy, and corneal thickness measurements showed that the construct implants can regenerate corneal endothelium and restore corneal transparency at 4 weeks postoperatively. Our findings suggest that cell sheet transplantation using overrun-processed porous HA hydrogels offers a new way to reconstruct the posterior corneal surface and improve endothelial tissue function.

  17. Plastic compressed collagen as a novel carrier for expanded human corneal endothelial cells for transplantation.

    Directory of Open Access Journals (Sweden)

    Hannah J Levis

    Full Text Available Current treatments for reversible blindness caused by corneal endothelial cell failure involve replacing the failed endothelium with donor tissue using a one donor-one recipient strategy. Due to the increasing pressure of a worldwide donor cornea shortage there has been considerable interest in developing alternative strategies to treat endothelial disorders using expanded cell replacement therapy. Protocols have been developed which allow successful expansion of endothelial cells in vitro but this approach requires a supporting material that would allow easy transfer of cells to the recipient. We describe the first use of plastic compressed collagen as a highly effective, novel carrier for human corneal endothelial cells. A human corneal endothelial cell line and primary human corneal endothelial cells retained their characteristic cobblestone morphology and expression of tight junction protein ZO-1 and pump protein Na+/K+ ATPase α1 after culture on collagen constructs for up to 14 days. Additionally, ultrastructural analysis suggested a well-integrated endothelial layer with tightly opposed cells and apical microvilli. Plastic compressed collagen is a superior biomaterial in terms of its speed and ease of production and its ability to be manipulated in a clinically relevant manner without breakage. This method provides expanded endothelial cells with a substrate that could be suitable for transplantation allowing one donor cornea to potentially treat multiple patients.

  18. Hyaluronan protection of corneal endothelial cells against extracellular histones after phacoemulsification.

    Science.gov (United States)

    Kawano, Hiroki; Sakamoto, Taiji; Ito, Takashi; Miyata, Kazunori; Hashiguchi, Teruto; Maruyama, Ikuro

    2014-11-01

    To determine the effect of histones on corneal endothelial cells generated during cataract surgery. Kagoshima University Hospital, Kagoshima, Japan. Experimental study. Standard phacoemulsification was performed on enucleated pig eyes. Histones in the anterior segment of the eye were determined by immunohistochemistry. Cultured human corneal endothelial cells were exposed to histones for 18 hours, and cell viability was determined by 2-(2-methoxy-4-nitrophenyl)-3-(4-nitro-phenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt assay. The concentration of interleukin-6 (IL-6) in the culture medium of human corneal endothelial cells was measured using enzyme-linked immunosorbent assay. The effects of signal inhibitors U0126, SB203580, and SP600125 were evaluated. The protective effect of hyaluronan against histones was evaluated in human corneal endothelial cells with and without hyaluronan. Cellular debris containing histones was observed in the anterior chamber of pig eyes after phacoemulsification. Exposure of human corneal endothelial cells to 50 μg/mL of histones or more led to cytotoxic effects. The IL-6 concentration was significantly increased dose dependently after exposure of human corneal endothelial cells to histones (Phistone-induced IL-6 production was significantly decreased by extracellular signal-regulated kinases 1/2 and p-38 mitogen-activated protein kinase inhibitors (Phistones caused formation of histone aggregates, decreased the cytotoxic effects of the histones, and blocked the increase in IL-6 (PHistones were released extracellularly during phacoemulsification and exposure of human corneal endothelial cells to histones increased the IL-6 secretion. The intraoperative use of hyaluronan may decrease the cytotoxic effects of histones released during cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Optimization of human corneal endothelial cell culture: density dependency of successful cultures in vitro.

    Science.gov (United States)

    Peh, Gary S L; Toh, Kah-Peng; Ang, Heng-Pei; Seah, Xin-Yi; George, Benjamin L; Mehta, Jodhbir S

    2013-05-03

    Global shortage of donor corneas greatly restricts the numbers of corneal transplantations performed yearly. Limited ex vivo expansion of primary human corneal endothelial cells is possible, and a considerable clinical interest exists for development of tissue-engineered constructs using cultivated corneal endothelial cells. The objective of this study was to investigate the density-dependent growth of human corneal endothelial cells isolated from paired donor corneas and to elucidate an optimal seeding density for their extended expansion in vitro whilst maintaining their unique cellular morphology. Established primary human corneal endothelial cells were propagated to the second passage (P2) before they were utilized for this study. Confluent P2 cells were dissociated and seeded at four seeding densities: 2,500 cells per cm2 ('LOW'); 5,000 cells per cm2 ('MID'); 10,000 cells per cm2 ('HIGH'); and 20,000 cells per cm2 ('HIGH(×2)'), and subsequently analyzed for their propensity to proliferate. They were also subjected to morphometric analyses comparing cell sizes, coefficient of variance, as well as cell circularity when each culture became confluent. At the two lower densities, proliferation rates were higher than cells seeded at higher densities, though not statistically significant. However, corneal endothelial cells seeded at lower densities were significantly larger in size, heterogeneous in shape and less circular (fibroblastic-like), and remained hypertrophic after one month in culture. Comparatively, cells seeded at higher densities were significantly homogeneous, compact and circular at confluence. Potentially, at an optimal seeding density of 10,000 cells per cm2, it is possible to obtain between 10 million to 25 million cells at the third passage. More importantly, these expanded human corneal endothelial cells retained their unique cellular morphology. Our results demonstrated a density dependency in the culture of primary human corneal endothelial

  20. [Contribution of confocal microscopy and anterior chamber OCT to the study of corneal endothelial pathologies].

    Science.gov (United States)

    Fayol, N; Labbé, A; Dupont-Monod, S; Dupas, B; Baudouin, C

    2007-04-01

    To describe the appearance of various endothelial diseases with in vivo confocal microscopy and anterior chamber optical coherence tomography (AC OCT). In this study, ten patients with five different corneal endothelial pathologies were evaluated. Three patients had cornea guttata, three had corneal endothelial precipitates, two had irido-corneo-endothelial (ICE) syndrome, one had endothelial folds, and one had breaks in the Descemet membrane. All patients had bilateral ophthalmologic examinations, in vivo confocal microscopy, and AC OCT analysis. In cases of cornea guttata, AC OCT showed a finely embossed line corresponding to the empty intercellular cavities found with in vivo confocal microscopy. Corneal endothelium precipitates had the aspect of round formations suspended with the endothelium. Iris atrophy and irido-corneal synechiae resulting from ICE syndrome were precisely visualized with the AC OCT. High-resolution images of the anterior segment could be obtained using the AC OCT. Associated with in vivo confocal microscopy, these two new imaging techniques provide a precise evaluation of endothelial pathologies.

  1. Atypical Presentation of Iridocorneal Endothelial Syndrome With Band Keratopathy but No Corneal Edema Managed With Descemet Membrane Endothelial Keratoplasty.

    Science.gov (United States)

    Zygoura, Vasiliki; Lavy, Itay; Verdijk, Robert M; Santander-García, Diana; Baydoun, Lamis; Dapena, Isabel; Melles, Gerrit R J

    2018-04-17

    To report an unusual presentation of iridocorneal endothelial (ICE) syndrome associated with band keratopathy and its management with ethylenediamine-tetraacetic acid (EDTA) chelation and Descemet membrane endothelial keratoplasty (DMEK). A 57-year-old female patient presented with unilateral progressive painless visual impairment, corneal band keratopathy, and morphological corneal endothelial changes without corneal edema or any previous ophthalmic, medical, or family history. Routine specular and confocal microscopy imaging, as well as biomicroscopy, best-corrected visual acuity, and pachymetry measurements were performed before and after the surgical procedures. Histopathologic and immunohistochemical evaluations of the surgically excised diseased DM-endothelium were performed. Superficial epithelial keratectomy with EDTA chelation was performed. After an initial period of a few months of corneal clearance, the patient presented with recurrence of visually significant band keratopathy. After 1 year, she underwent retreatment with superficial epithelial keratectomy and EDTA chelation, followed by DMEK. Histopathologic and immunohistochemical analysis showed ICE syndrome. Two years after DMEK surgery, the cornea was still clear and band keratopathy had not recurred. To the best of our knowledge, this is the first case in the literature that reports the association of ICE syndrome with band keratopathy. As band keratopathy recurred shortly after EDTA chelation, endothelial keratoplasty (DMEK) may be indicated to successfully treat such cases.

  2. Role of protein kinase C in regulation of Na+- and K +-dependent ATPase activity and pump function in corneal endothelial cells.

    Science.gov (United States)

    Hatou, Shin; Yamada, Masakazu; Mochizuki, Hiroshi; Nishida, Teruo

    2009-05-01

    Na+- and K+-dependent ATPase (Na,K-ATPase) plays an important role in the pump function of the corneal endothelium. We investigated the possible role of protein kinase C (PKC) in regulation of Na,K-ATPase activity and pump function in corneal endothelial cells. Confluent monolayers of mouse corneal endothelial cells were exposed to phorbol 12,13-dibutyrate (PDBu) to induce activation of PKC. ATPase activity of the cells was evaluated by using ammonium molybdate in spectrophotometric measurement of phosphate released from ATP, with Na,K-ATPase activity being defined as the portion of total ATPase activity sensitive to ouabain. Pump function of the cells was measured with a Ussing chamber, with the pump function attributable to Na,K-ATPase activity being defined as the portion of the total short-circuit current sensitive to ouabain. PDBu (10(-7) M) increased the Na,K-ATPase activity and pump function of the cultured cells. These effects of PDBu were potentiated by the cyclooxygenase inhibitor indomethacin and the cytochrome P(450) inhibitor resorufin and were blocked by okadaic acid, an inhibitor of protein phosphatases 1 and 2A. Our results suggest that PKC bidirectionally regulates Na,K-ATPase activity in mouse corneal endothelial cells: it inhibits Na,K-ATPase activity in a cyclooxygenase- and cytochrome P(450)-dependent manner, whereas it stimulates such activity by activating protein phosphatases 1 or 2A.

  3. Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

    Science.gov (United States)

    Módis, László Jr; Szalai, Eszter; Flaskó, Zsuzsa; Németh, Gábor

    2016-01-01

    To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories). Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary. 52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively. ECD values decreased significantly in both surgical groups (P .05). No significant correlation was found between the endothelial cell loss and the nucleus density. Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile.

  4. Effects of phthalates on the human corneal endothelial cell line B4G12

    DEFF Research Database (Denmark)

    Krüger, Tanja; Cao, Yi; Kjærgaard, Søren K.

    2012-01-01

    Phthalates are industrial chemicals used in many cosmetics. We evaluated an in vitro model for eye irritancy testing using the human corneal endothelial cell line B4G12. Cell proliferation and toxicity were assessed after exposing to di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), di-2...... toxicity was observed for DBP and BBP. Upon DBP exposure at nontoxic concentrations, a significant increased gene expression and cytokine cell secretion were observed for interleukin-1ß (IL-1ß) and IL-8, and also an increased IL-6 secretion was observed. In conclusion, the human corneal endothelial cell...

  5. Corneal endothelial morphology and central thickness in patients with type II diabetes mellitus

    DEFF Research Database (Denmark)

    Storr-Paulsen, Allan; Singh, Amardeep; Jeppesen, Helene

    2014-01-01

    size was based on a power calculation (power = 0.90; p = 0.05). The diabetic patients had on average more than four HbA1c tests performed (mean 4.1; range 2-14) with intervals of at least 3 months as a reflection of the long-term glycaemic status. The controls had no diabetes confirmed by two causal......PURPOSE: To investigate corneal endothelial cell density and morphology in type II diabetic and non-diabetic patients and to relate potential differences to the glycaemic status. METHODS: A prospective clinical study including 107 patients with type II diabetes and 128 non-diabetic patients. Sample...... blood tests. The endothelial cell density, the variation in endothelial cell size (CV), the percentage of hexagonal cells, and the central corneal thickness (CCT) were recorded. RESULTS: Type II diabetic subjects did not differ from the non-diabetic control subjects with regards to endothelial cell...

  6. TGF-β2 inhibits AKT activation and FGF-2-induced corneal endothelial cell proliferation

    International Nuclear Information System (INIS)

    Lu Jiawei; Lu Zhenyu; Reinach, Peter

    2006-01-01

    The corneal endothelial cells form a boundary layer between anterior chamber and cornea. This single cell layer is important to maintain cornea transparency by eliciting net fluid transport into the anterior chamber. Injuries of the corneal endothelial layer in humans lead to corneal swelling and translucence. This hindrance is thought to be due to limited proliferative capacity of the endothelial layer. Fibroblast growth factor 2 (FGF-2) and transforming growth factor-beta 2 (TGF-β2) are both found in aqueous humor, and these two cytokines promote and inhibit cell growth, respectively. The intracellular signaling mechanisms by which TGF-β2 suppresses the mitogenic response to FGF-2, however, remain unclear. We have addressed this question by investigating potential crosstalk between FGF-2-induced and TGF-β2-regulated intracellular signaling events in cultured bovine corneal endothelial (BCE) cells. We found that TGF-β2 and FGF-2 oppositely affect BCE cell proliferation and TGF-β2 can override the stimulating effects of FGF-2 by increasing COX-2 expression in these cells. Consistent with these findings, overexpression of COX-2 significantly reduced FGF-2-induced cell proliferation whereas a COX-2 specific inhibitor NS398 reversed the effect of TGF-β2 on FGF-2-induced cell proliferation. The COX-2 product prostaglandin E2 (PGE-2) blocks FGF-2-induced cell proliferation. Whereas FGF-2 stimulates cell proliferation by activating the AKT pathway, TGF-β2 and PGE-2 both inhibit this pathway. In accordance with the effect of PGE-2, cAMP also inhibits FGF-2-induced AKT activation. These findings suggest that the mitogenic response to FGF-2 in vivo in the corneal endothelial layer may be inhibited by TGF-β2-induced suppression of the PI3-kinase/AKT signaling pathway

  7. Proteomics of Fuchs' Endothelial Corneal Dystrophy support that the extracellular matrix of Descemet's membrane is disordered

    DEFF Research Database (Denmark)

    Poulsen, Ebbe Toftgaard; Dyrlund, Thomas F; Runager, Kasper

    2014-01-01

    Fuchs' endothelial corneal dystrophy (FECD) is a major corneal disorder affecting the innermost part of the cornea, leading to visual impairment. As the morphological changes in FECD are mainly observed in the extracellular matrix of the Descemet's membrane/endothelial layer we determined...... that the morphological changes observed in FECD is caused in part by an aberrant assembly of the extracellular matrix within the Descemet's membrane/endothelial layer......., respectively, of which 10 were significantly regulated. The results indicated that the level of type VIII collagen was unaltered even though the protein previously has been implicated in familial early onset forms of the disease. Using the second relative quantitation method iTRAQ we identified 22...

  8. Establishment of functioning human corneal endothelial cell line with high growth potential.

    Directory of Open Access Journals (Sweden)

    Tadashi Yokoi

    Full Text Available Hexagonal-shaped human corneal endothelial cells (HCEC form a monolayer by adhering tightly through their intercellular adhesion molecules. Located at the posterior corneal surface, they maintain corneal translucency by dehydrating the corneal stroma, mainly through the Na(+- and K(+-dependent ATPase (Na(+/K(+-ATPase. Because HCEC proliferative activity is low in vivo, once HCEC are damaged and their numbers decrease, the cornea begins to show opacity due to overhydration, resulting in loss of vision. HCEC cell cycle arrest occurs at the G1 phase and is partly regulated by cyclin-dependent kinase inhibitors (CKIs in the Rb pathway (p16-CDK4/CyclinD1-pRb. In this study, we tried to activate proliferation of HCEC by inhibiting CKIs. Retroviral transduction was used to generate two new HCEC lines: transduced human corneal endothelial cell by human papillomavirus type E6/E7 (THCEC (E6/E7 and transduced human corneal endothelial cell by Cdk4R24C/CyclinD1 (THCEH (Cyclin. Reverse transcriptase polymerase chain reaction analysis of gene expression revealed little difference between THCEC (E6/E7, THCEH (Cyclin and non-transduced HCEC, but cell cycle-related genes were up-regulated in THCEC (E6/E7 and THCEH (Cyclin. THCEH (Cyclin expressed intercellular molecules including ZO-1 and N-cadherin and showed similar Na(+/K(+-ATPase pump function to HCEC, which was not demonstrated in THCEC (E6/E7. This study shows that HCEC cell cycle activation can be achieved by inhibiting CKIs even while maintaining critical pump function and morphology.

  9. Changes in corneal endothelial cell density and the cumulative risk of corneal decompensation after Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Kim, Kyoung Nam; Lee, Sung Bok; Lee, Yeon Hee; Lee, Jong Joo; Lim, Hyung Bin; Kim, Chang-Sik

    2016-07-01

    To evaluate changes in the corneal endothelial cell density (ECD) and corneal decompensation following Ahmed glaucoma valve (AGV) implantation. This study was retrospective and observational case series. Patients with refractory glaucoma who underwent AGV implantation and were followed >5 years were consecutively enrolled. We reviewed the medical records, including the results of central corneal specular microscopy. Of the 127 enrolled patients, the annual change in ECD (%) was determined using linear regression for 72 eyes evaluated at least four times using serial specular microscopic examination and compared with 31 control eyes (fellow glaucomatous eyes under medical treatment). The main outcome measures were cumulative risk of corneal decompensation and differences in the ECD loss rates between subjects and controls. The mean follow-up after AGV implantation was 43.1 months. There were no cases of postoperative tube-corneal touch. The cumulative risk of corneal decompensation was 3.3%, 5 years after AGV implantation. There was a more rapid loss of ECD in the 72 subject eyes compared with the 31 controls (-7.0% and -0.1%/year, respectively; p<0.001). However, the rate of loss decreased over time and statistical significance compared with control eyes disappeared after 2 years postoperatively: -10.7% from baseline to 1 year (p<0.01), -7.0% from 1 year to 2 years (p=0.037), -4.2% from 2 years to 3 years (p=0.230) and -2.7% from 3 years to the final follow-up (p=0.111). In case of uncomplicated AGV implantation, the cumulative risk of corneal decompensation was 3.3%, 5 years after the operation. The ECD loss was statistically greater in eyes with AGV than in control eyes without AGV, but the difference was significant only up to 2 years post surgery. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Corneal endothelial expansion promoted by human bone marrow mesenchymal stem cell-derived conditioned medium.

    Directory of Open Access Journals (Sweden)

    Makiko Nakahara

    Full Text Available Healthy corneal endothelium is essential for maintaining corneal clarity, as the damage of corneal endothelial cells and loss of cell count causes severe visual impairment. Corneal transplantation is currently the only therapy for severe corneal disorders. The greatly limited proliferative ability of human corneal endothelial cells (HCECs, even in vitro, has challenged researchers to establish efficient techniques for the cultivating HCECs, a pivotal issue for clinical applications. The aim of this study was to evaluate conditioned medium (CM obtained from human bone marrow-derived mesenchymal stem cells (MSCs (MSC-CM for use as a consistent expansion protocol of HCECs. When HCECs were maintained in the presence of MSC-CM, cell morphology assumed a hexagonal shape similar to corneal endothelial cells in vivo, as opposed to the irregular cell shape observed in control cultures in the absence of MSC-CM. They also maintained the functional protein phenotypes; ZO-1 and Na(+/K(+-ATPase were localized at the intercellular adherent junctions and pump proteins of corneal endothelium were accordingly expressed. In comparison to the proliferative potential observed in the control cultures, HCECs maintained in MSC-CM were found to have more than twice as many Ki67-positive cells and a greatly increased incorporation of BrdU into DNA. MSC-CM further facilitated the cell migration of HCECs. Lastly, the mechanism of cell proliferation mediated by MSC-CM was investigated, and phosphorylation of Akt and ERK1/2 was observed in HCECs after exposure to MSC-CM. The inhibitor to PI 3-kinase maintained the level of p27(Kip1 for up to 24 hours and greatly blocked the expression of cyclin D1 and D3 during the early G1 phase, leading to the reduction of cell density. These findings indicate that MSC-CM not only stimulates the proliferation of HCECs by regulating the G1 proteins of the cell cycle but also maintains the characteristic differentiated phenotypes necessary

  11. Cultivation of Human Microvascular Endothelial Cells on Topographical Substrates to Mimic the Human Corneal Endothelium

    Directory of Open Access Journals (Sweden)

    Jie Shi Chua

    2013-03-01

    Full Text Available Human corneal endothelial cells have a limited ability to replicate in vivo and in vitro. Allograft transplantation becomes necessary when an accident or trauma results in excessive cell loss. The reconstruction of the cornea endothelium using autologous cell sources is a promising alternative option for therapeutic or in vitro drug testing applications. The native corneal endothelium rests on the Descemet’s membrane, which has nanotopographies of fibers and pores. The use of synthetic topographies mimics the native environment, and it is hypothesized that this can direct the behavior and growth of human microvascular endothelial cells (HMVECs to resemble the corneal endothelium. In this study, HMVECs are cultivated on substrates with micron and nano-scaled pillar and well topographies. Closely packed HMVEC monolayers with polygonal cells and well-developed tight junctions were formed on the topographical substrates. Sodium/potassium (Na+/K+ adenine triphosphatase (ATPase expression was enhanced on the microwells substrate, which also promotes microvilli formation, while more hexagonal-like cells are found on the micropillars samples. The data obtained suggests that the use of optimized surface patterning, in particular, the microtopographies, can induce HMVECs to adopt a more corneal endothelium-like morphology with similar barrier and pump functions. The mechanism involved in cell contact guidance by the specific topographical features will be of interest for future studies.

  12. Effects of vitrectomy combined with cataract surgery on the corneal endothelial cells in diabetic retinopathy

    OpenAIRE

    Lei Zhan; Si-Ying Xiong; Meng-Xin Gan; Li-Hui Wen

    2017-01-01

    AIM: To investigate the effects of vitrectomy combined with cataract surgery on the corneal endothelial cells in diabetic retinopathy. METHODS: A retrospective study was designed. 160 patients(160 eyes)with diabetic retinopathy from Jan 2015 to Feb 2017 were divided into two groups according to cataract. 74 patients(74 eyes)were operated on vitrectomy, and 86 patients(86 eyes)on vitrectomy combined with phacoemulsification cataract surgery and capsular bag implantation of foldable intraocular...

  13. Comparison of the corneal endothelial cell count in type II diabetic patients with healthy adults

    International Nuclear Information System (INIS)

    Rizvi, B.Z.; Zafar, O.

    2016-01-01

    To compare the mean corneal endothelial cell count in type II diabetic patients with healthy adults. Study Design: Case control. Place and Duration of Study: Out-patient Department of Armed Forces Institute of Ophthalmology, Rawalpindi from September 10, 2013 to March 25, 2014. Material and Methods: A hospital-based case-control study was carried out at out-patient department of Armed Forces Institute of Ophthalmology in which 130 eyes (65 diabetic eyes and 65 controls) were included. Non-probability consecutive sampling was adopted. Relevant detailed history including information about age, gender, duration of diabetes, any other medical illness and current medical treatment being taken by patient was recorded. Results: Data entry and analysis was done in SPSS version 10. Total 130 eyes (65 diabetic and 65 non-diabetic eyes) were included in our study according to the inclusion criteria. Mean age (years) of patient in both the groups was 59.55 +- 8.01 and 53.85 +- 10.07. Mean corneal endothelial cell count in both the groups was 2368.35 +- 389.58 and 2588.64 +- 269.84 respectively which was statistically significant (p-value=0.001) in both the groups. Conclusion: The conclusion of the study was that the mean corneal endothelial cell count in type II diabetic patients was significantly less as compared to healthy adults. (author)

  14. Revisited microanatomy of the corneal endothelial periphery: new evidence for continuous centripetal migration of endothelial cells in humans.

    Science.gov (United States)

    He, Zhiguo; Campolmi, Nelly; Gain, Philippe; Ha Thi, Binh Minh; Dumollard, Jean-Marc; Duband, Sébastien; Peoc'h, Michel; Piselli, Simone; Garraud, Olivier; Thuret, Gilles

    2012-11-01

    The control of corneal transparency depends on the integrity of its endothelial monolayer, which is considered nonregenerative in adult humans. In pathological situations, endothelial cell (EC) loss, not offset by mitosis, can lead to irreversible corneal edema and blindness. However, the hypothesis of a slow, clinically insufficient regeneration starting from the corneal periphery remains debatable. The authors have re-evaluated the microanatomy of the endothelium in order to identify structures likely to support this homeostasis model. Whole endothelia of 88 human corneas (not stored, and stored in organ culture) with mean donor age of 80 ± 12 years were analyzed using an original flat-mounting technique. In 61% of corneas, cells located at the extreme periphery (last 200 μm of the endothelium) were organized in small clusters with two to three cell layers around Hassall-Henle bodies. In 68% of corneas, peripheral ECs formed centripetal rows 830 ± 295 μm long, with Descemet membrane furrows visible by scanning electron microscopy. EC density was significantly higher in zones with cell rows. When immunostained, ECs in the extreme periphery exhibited lesser differentiation (ZO-1, Actin, Na/K ATPase, CoxIV) than ECs in the center of the cornea but preferentially expressed stem cell markers (Nestin, Telomerase, and occasionally breast cancer resistance protein) and, in rare cases, the proliferation marker Ki67. Stored corneas had fewer cell clusters but more Ki67-positive ECs. We identified a novel anatomic organization in the periphery of the human corneal endothelium, suggesting a continuous slow centripetal migration, throughout life, of ECs from specific niches. Copyright © 2012 AlphaMed Press.

  15. Changes in corneal sensation, epithelial damage, and tear function after descemet stripping automated endothelial keratoplasty.

    Science.gov (United States)

    Hirayama, Yumiko; Satake, Yoshiyuki; Hirayama, Masatoshi; Shimazaki-Den, Seika; Konomi, Kenji; Shimazaki, Jun

    2013-09-01

    To study the ocular surface changes in eyes after Descemet stripping automated endothelial keratoplasty (DSAEK) compared with those after penetrating keratoplasty (PKP). This prospective study compared the changes in 31 eyes of 28 patients who underwent DSAEK (DSAEK group) with those in 15 disease-matched eyes of 15 patients who underwent PKP (PKP group). Corneal epithelial integrity was evaluated using a fluorescein staining score. Corneal sensation was measured with a Cochet-Bonnet esthesiometer. Tear function was evaluated using the Schirmer test, tear clearance test, tear function index, and tear break-up time. The postoperative fluorescein staining score was significantly higher in the PKP group than in the DSAEK group (P = 0.02). Postoperative corneal sensation was significantly better in the DSAEK group than in the PKP group (P sensation after DSAEK was significantly better than the preoperative value (P = 0.02). There were no statistically significant changes in the Schirmer test, tear clearance test, tear function index, or break-up time before and after the surgery in both the DSAEK and PKP groups. No significant differences were observed between the DSAEK and PKP groups after the surgery. Corneal sensation was preserved, and epithelial damage was less severe after DSAEK compared with PKP. Preservation of corneal sensation may contribute to the early recovery of visual function and long-term maintenance of ocular surface health after DSAEK.

  16. Safety of intracameral injection of gatifloxacin, levofloxacin on corneal endothelial structure and viability.

    Science.gov (United States)

    Choi, Jin A; Chung, Sung Kun

    2009-10-01

    To investigate the safety of intracameral injection of gatifloxacin, levofloxacin in a rabbit model as prophylaxis against endophthalmitis. Twenty-four eyes of New Zealand white rabbits were randomly divided into 3 treatment groups: levofloxacin, gatifloxacin, and balanced salt solution (BSS) control groups. After 100 microL of each was injected into the anterior chamber, endothelial toxicity was evaluated by measuring the central corneal thicknesses and the clinical toxicity scores using a slit-lamp at post-procedure days 3 and 7. The percent of dead cells was determined by vital staining with alizarin red and trypan blue at 7 days after injection. Finally, in each group, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were performed for the evaluation of structural integrity. The toxicity scores were increased at post-procedure days 3 and 7, but the difference among the groups was not statistically significant (P = 0.661, 0.216, respectively). With regard to baseline corneal thickness, only the levofloxacin group exhibited a significant increase from baseline (P = 0.028), whereas the other treatment groups showed no difference from baseline (P = 0.128 in gatifloxacin, 0.161 in BSS group). The mean corneal endothelial damage was 0.81 +/- 0.31% in the levofloxacin group, 0.56 +/- 0.47% in the gatifloxacin group, and 0.53 +/- 0.52% in the BSS group, with no statistically significant difference noted among the groups (P = 0.582). SEM revealed a well-preserved hexagonal endothelial cell mosaic and normal microvilli on the endothelial cell surface in the gatifloxacin and control groups. However, the levofloxacin group showed slightly disintegrated cellular borders. TEM revealed that each group maintained normal intracellular organization, whereas the levofloxacin group exhibited slightly flat cell configuration with irregular folds on the apical cell surface. Intracameral injection of gatifloxacin and levofloxacin was nontoxic in terms of

  17. Corneal endothelial rejection after penetrating keratoplasty treated with intravenous and topic corticosteroid: one year follow up

    Directory of Open Access Journals (Sweden)

    Ricardo Yuji Abe

    2013-02-01

    Full Text Available OBJECTIVE: To analyze the recovery of visual acuity (VA and graft survival after first episode of endothelial rejection in penetrating keratoplasty (PKP treated with intravenous (IV and topic corticosteroid. METHODS: Interventional, prospective, non-comparative case series study evolving 32 PKP patients in one year follow up, who presented first episode of corneal endothelial rejection. The patients were submitted to 500 mg IV injection of methylprednisolone in association with topical prednisolone. Main outcome measures included VA recovery and corneal edema regression. Second outcome included new rejections and graft failure. Multivariate analysis techniques were used to estimate rates of graft outcome events and the impact of risk factors. RESULTS: A total of 32 eyes from 32 patients (13 male and 19 female were included in the study. The mean VA (in number of letters before rejection was 48 (22 to 88 letters. Patients treated within 7 days or less of initial symptoms had better VA recovery, corneal edema regression and less graft failure (p<0.001. Patients with previous ocular surgery had worse VA recovery and more graft failure (p<0.047. CONCLUSION: The association between the other risk factors and the outcomes did not reach statistical significance in the multivariate model because of the small numbers of patients. Methylprednisolone in association with topical prednisolone is an alternative treatment for graft rejection. Our study showed that patients treated within 7 days of symptoms and no previous anterior segment surgery had better visual outcome and graft survival after treatment.

  18. Cultivation of corneal endothelial cells on a pericellular matrix prepared from human decidua-derived mesenchymal cells.

    Directory of Open Access Journals (Sweden)

    Ryohei Numata

    Full Text Available The barrier and pump functions of the corneal endothelium are essential for the maintenance of corneal transparency. Although corneal transplantation is the only current therapy for treating corneal endothelial dysfunction, the potential of tissue-engineering techniques to provide highly efficient and less invasive therapy in comparison to corneal transplantation has been highly anticipated. However, culturing human corneal endothelial cells (HCECs is technically difficult, and there is no established culture protocol. The aim of this study was to investigate the feasibility of using a pericellular matrix prepared from human decidua-derived mesenchymal cells (PCM-DM as an animal-free substrate for HCEC culture for future clinical applications. PCM-DM enhanced the adhesion of monkey CECs (MCECs via integrin, promoted cell proliferation, and suppressed apoptosis. The HCECs cultured on the PCM-DM showed a hexagonal morphology and a staining profile characteristic of Na⁺/K⁺-ATPase and ZO-1 at the plasma membrane in vivo, whereas the control HCECs showed a fibroblastic phenotype. The cell density of the cultured HCECs on the PCM-DM was significantly higher than that of the control cells. These results indicate that PCM-DM provides a feasible xeno-free matrix substrate and that it offers a viable in vitro expansion protocol for HCECs while maintaining cellular functions for use as a subsequent clinical intervention for tissue-engineered based therapy of corneal endothelial dysfunction.

  19. A Cell Culture Approach to Optimized Human Corneal Endothelial Cell Function

    Science.gov (United States)

    Bartakova, Alena; Kuzmenko, Olga; Alvarez-Delfin, Karen; Kunzevitzky, Noelia J.; Goldberg, Jeffrey L.

    2018-01-01

    Purpose Cell-based therapies to replace corneal endothelium depend on culture methods to optimize human corneal endothelial cell (HCEC) function and minimize endothelial-mesenchymal transition (EnMT). Here we explore contribution of low-mitogenic media on stabilization of phenotypes in vitro that mimic those of HCECs in vivo. Methods HCECs were isolated from cadaveric donor corneas and expanded in vitro, comparing continuous presence of exogenous growth factors (“proliferative media”) to media without those factors (“stabilizing media”). Identity based on canonical morphology and expression of surface marker CD56, and function based on formation of tight junction barriers measured by trans-endothelial electrical resistance assays (TEER) were assessed. Results Primary HCECs cultured in proliferative media underwent EnMT after three to four passages, becoming increasingly fibroblastic. Stabilizing the cells before each passage by switching them to a media low in mitogenic growth factors and serum preserved canonical morphology and yielded a higher number of cells. HCECs cultured in stabilizing media increased both expression of the identity marker CD56 and also tight junction monolayer integrity compared to cells cultured without stabilization. Conclusions HCECs isolated from donor corneas and expanded in vitro with a low-mitogenic media stabilizing step before each passage demonstrate more canonical structural and functional features and defer EnMT, increasing the number of passages and total canonical cell yield. This approach may facilitate development of HCEC-based cell therapies. PMID:29625488

  20. Femtosecond laser cutting of multiple thin corneal stromal lamellae for endothelial bioengineering.

    Science.gov (United States)

    Bernard, Aurélien; He, Zhiguo; Forest, Fabien; Gauthier, Anne-Sophie; Peocʼh, Michel; Dumollard, Jean-Marc; Acquart, Sophie; Montard, Romain; Delbosc, Bernard; Gain, Philippe; Thuret, Gilles

    2015-02-01

    To assess the feasibility of cutting multiple thin stromal lamellae in human donor corneas using a commercial femtosecond laser (FSL) to provide cell carriers for future endothelial graft bioengineering. Eight edematous organ-cultured corneas not suitable for grafting for endothelial reasons were mounted on a Ziemer anterior chamber and cut with a Z6 FSL with 6 successive parallel cuts, from depth to surface. Target thickness of each lamella ranged from 100 to 150 μm depending on initial corneal thickness. Thickness was measured using anterior segment optical coherence tomography before and after cutting on mounted corneas, and on each stromal lamella after detachment. Scanning electron microscopy observation was performed on 4 lamellae and histological cross sections on 1 cornea before detachment. A median of 5 (minimum 3, maximum 7) lamellae was obtained per cornea. All lamellae still attached were the most posterior ones, suggesting that FSL was less efficient because of light scattering by edematous stroma. Cut precision and postdetachment swelling were correlated with anterior-posterior position within the cornea. Median lamella thickness was 127 μm (56-222 μm) before detachment and 196 μm (80-304 μm) after detachment. Surface state was consistent with previously reported FSL lamellar cuts during Descemet stripping automated endothelial keratoplasty. Up to 7 thin lamellae can be cut in stored corneas with an FSL. This method, once optimized primarily by using deswelled, more transparent corneas, could prove effective for recycling unsuitable donor corneas in corneal bioengineering processes.

  1. Corneal endothelial cell density and morphology in low and moderate myopic Chinese eyes

    Directory of Open Access Journals (Sweden)

    Jane Mei Chun

    2013-08-01

    Full Text Available AIM: To describe and compare the corneal endothelial cell density and morphology in young, low and moderate myopic Chinese adults in Malaysian Chinese population.METHODS: Non-contact specular microscopy (Topcon SP3000P, Tokyo, Japan was performed in low (n=78; 21.22±1.51 years and moderate (n=78; 21.82±1.40 years myopic subjects. The mean of three consecutive measurements of endothelial cell density (MCD, coefficient of variation (CV in the cell size, and hexagonal appearance of the cell were obtained.RESULTS: In low myopic eyes the MCD was 3 063.0±176.2/mm2, the mean CV was 33.4±4.0% and the mean hexagonal appearance of the cell was 57.9±2.7%. In moderate myopic eyes the MCD was 2961.6±159.0/mm2, the mean CV was 33.9±3.6% and mean hexagonal appearance of the cell was 56.2±4.7%. There were statistically significant differences in MCD (PPCONCLUSION:The corneal endothelial cell layer in more myopic eyes tends to have less MCD and cell hexagonality compared to lower myopic eyes. Nevertheless, there is no significant difference in CV between low and moderate myopic eyes.

  2. Cytotoxic effects of betaxolol on healthy corneal endothelial cells both in vitro and in vivo

    Directory of Open Access Journals (Sweden)

    Ying Miao

    2014-02-01

    Full Text Available AIM: To demonstrate the cytotoxic effect of betaxolol and its underlying mechanism on human corneal endothelial cells(HCE cells in vitro and cat corneal endothelial cells(CCE cells in vivo, providing experimental basis for safety anti-glaucoma drug usage in clinic of ophthalmology.METHODS: In vivo and in vitro experiments were conducted to explore whether and how betaxolol participates in corneal endothelial cell injury. The in vitro morphology, growth status, plasma membrane permeability, DNA fragmentation, and ultrastructure of HCE cells treated with 0.021875-0.28g/L betaxolol were examined by light microscope, 3-(4,5-dimethylthiahiazo (-z-y1-3,5-di-phenytetrazoliumromide (MTT assay, acridine orange (AO/ethidium bromide (EB double-fluorescent staining, DNA agarose gel electrophoresis, and transmission electron microscope (TEM. The in vivo density, morphology, and ultrastructure of CCE cells, corneal thickness, and eye pressure of cat eyes treated with 0.28g/L betaxolol were investigated by specular microscopy, applanation tonometer, alizarin red staining, scanning electron microscope (SEM, and TEM.RESULTS: Exposure to betaxolol at doses from 0.0875g/L to 2.8g/L induced morphological and ultrastructural changes of in vitro cultured HCE cells such as cytoplasmic vacuolation, cellular shrinkage, structural disorganization, chromatin condensation, and apoptotic body appearance. Simultaneously, betaxolol elevated plasma membrane permeability and induced DNA fragmentation of these cells in a dose-dependent manner in AO/EB staining. Furthermore, betaxolol at a dose of 2.8g/L also induced decrease of density of CCE cells in vivo, and non-hexagonal and shrunk apoptotic cells were also found in betaxolol-treated cat corneal endothelia.CONCLUSION: Betaxolol has significant cytotoxicity on HCE cells in vitro by inducing apoptosis of these cells, and induced apoptosis of CCE cells in vivo as well. The findings help provide new insight into the apoptosis

  3. Radioprotection of mouse CNS endothelial cells in vivo

    International Nuclear Information System (INIS)

    Lyubimova, N.; Coultas, P.; Martin, R.

    1996-01-01

    Full text: Radioprotection using the minor groove binding DNA ligand Hoechst 33342 has been demonstrated in vitro, and more recently in vivo, in mouse lung. Intravenous administration was used for the lung studies, and both endothelial and alveolar epithelial cells-showed good up-take. Radiation damage to the endothelial cell population has also been postulated as important in late developing radionecrosis of spinal cord and brain. Endothelial cell density in brain can be readily determined by a fluorescent-histochemical technique. Treatment with a monoamine oxidase inhibitor and subsequent injection with L-DOPA results in an accumulation of dopamine (DA) in CNS endothelial cells. DA is converted to a fluorophore by exposure to paraformaldehyde, and cell numbers assayed by fluorescence microscopy. Earlier studies used this technique to monitor post-irradiation changes in endothelial cell density in rodent brain and showed the loss, within 24 hours, of a sensitive subpopulation comprising about 15% of the endothelial cells. Ten minutes after intravenous injection of Hoechst 33342 (80mg/kg) the ligand is confined by its limited penetration to the endothelial cells in mouse brain. When we irradiated at this time, there was protection against early endothelial cell loss. Ablation of the sensitive subpopulation in unprotected mice takes place over a dose range of 1 to 3 Gy γ-rays, but doses between 12 to 20 Gy are required in the presence of ligand. This protection equates to a very high dose modification factor of about 7 and possibly reflects a suppression of apoptosis in the sensitive endothelial subpopulation. The extent to which there is enhanced survival in the endothelial population as a whole and how the observed protection affects late CNS necrosis development has yet to be determined. However present results clearly show potential for the use of DNA-binding radioprotectors with limited penetration for investigations into the relative significance of

  4. Derivation of corneal endothelial cell-like cells from rat neural crest cells in vitro.

    Directory of Open Access Journals (Sweden)

    Chengqun Ju

    Full Text Available The aim of this study was to investigate the feasibility of inducing rat neural crest cells (NCC to differentiate to functional corneal endothelial cell (CEC-like cells in vitro. Rat NCC were induced with adult CEC-derived conditioned medium. Immunofluorescence, flow cytometry and real time RT-PCR assay were used to detect expression of the corneal endothelium differentiation marker N-cadherin and transcription factors FoxC1 and Pitx2. CFDA SE-labeled CEC-like cells were transplanted to the corneal endothelium of a rat corneal endothelium deficiency model, and an eye-down position was maintained for 24 hours to allow cell attachment. The animals were observed for as long as 2 months after surgery and underwent clinical and histological examination. Spindle-like NCC turned to polygonal CEC-like after induction and expressed N-cadherin, FoxC1, Pitx2, zonula occludens-1 and sodium-potassium pump Na(+/K(+ ATPase. The corneas of the experimental group were much clearer than those of the control group and the mean corneal thickness in the experimental group was significantly less than in the control group7, 14, 21 and 28 days after surgery. Confocal microscopy through focusing and histological analysis confirmed that green fluorescence-positive CEC-like cells formed a monolayer covering the Descemet's membrane in the experimental group. In conclusion, CEC-like cells derived from NCCs displayed characters of native CEC, and the induction protocol provides guidance for future human CEC induction from NCC.

  5. Preparation of arginine–glycine–aspartic acid-modified biopolymeric nanoparticles containing epigalloccatechin-3-gallate for targeting vascular endothelial cells to inhibit corneal neovascularization

    Science.gov (United States)

    Chang, Che-Yi; Wang, Ming-Chen; Miyagawa, Takuya; Chen, Zhi-Yu; Lin, Feng-Huei; Chen, Ko-Hua; Liu, Guei-Sheung; Tseng, Ching-Li

    2017-01-01

    Neovascularization (NV) of the cornea can disrupt visual function, causing ocular diseases, including blindness. Therefore, treatment of corneal NV has a high public health impact. Epigalloccatechin-3-gallate (EGCG), presenting antiangiogenesis effects, was chosen as an inhibitor to treat human vascular endothelial cells for corneal NV treatment. An arginine–glycine–aspartic acid (RGD) peptide–hyaluronic acid (HA)-conjugated complex coating on the gelatin/EGCG self-assembly nanoparticles (GEH-RGD NPs) was synthesized for targeting the αvβ3 integrin on human umbilical vein endothelial cells (HUVECs) in this study, and a corneal NV mouse model was used to evaluate the therapeutic effect of this nanomedicine used as eyedrops. HA-RGD conjugation via COOH and amine groups was confirmed by 1H-nuclear magnetic resonance and Fourier-transform infrared spectroscopy. The average diameter of GEH-RGD NPs was 168.87±22.5 nm with positive charge (19.7±2 mV), with an EGCG-loading efficiency up to 95%. Images of GEH-RGD NPs acquired from transmission electron microscopy showed a spherical shape and shell structure of about 200 nm. A slow-release pattern was observed in the nanoformulation at about 30% after 30 hours. Surface plasmon resonance confirmed that GEH-RGD NPs specifically bound to the integrin αvβ3. In vitro cell-viability assay showed that GEH-RGD efficiently inhibited HUVEC proliferation at low EGCG concentrations (20 μg/mL) when compared with EGCG or non-RGD-modified NPs. Furthermore, GEH-RGD NPs significantly inhibited HUVEC migration down to 58%, lasting for 24 hours. In the corneal NV mouse model, fewer and thinner vessels were observed in the alkali-burned cornea after treatment with GEH-RGD NP eyedrops. Overall, this study indicates that GEH-RGD NPs were successfully developed and synthesized as an inhibitor of vascular endothelial cells with specific targeting capacity. Moreover, they can be used in eyedrops to inhibit angiogenesis in corneal NV

  6. In vitro evaluation of the interactions between human corneal endothelial cells and extracellular matrix proteins

    International Nuclear Information System (INIS)

    Choi, Jin San; Kim, Eun Young; Kim, Min Jeong; Giegengack, Matthew; Khan, Faraaz A; Soker, Shay; Khang, Gilson

    2013-01-01

    The corneal endothelium is the innermost cell layer of the cornea and rests on Descemet's membrane consisting of various extracellular matrix (ECM) proteins which can directly affect the cellular behaviors such as cell adhesion, proliferation, polarity, morphogenesis and function. The objective of this study was to investigate the interactions between the ECM environment and human corneal endothelial cells (HCECs), with the ultimate goal to improve cell proliferation and function in vitro. To evaluate the interaction of HCECs with ECM proteins, cells were seeded on ECM-coated tissue culture dishes, including collagen type I (COL I), collagen type IV (COL IV), fibronectin (FN), FNC coating mix (FNC) and laminin (LM). Cell adhesion and proliferation of HCECs on each substratum and expression of CEC markers were studied. The results showed that HCECs plated on the COL I, COL IV, FN and FNC-coated plates had enhanced cell adhesion initially; the number for COL I, COL IV, FN and FNC was significantly higher than the control (P < 0.05). In addition, cells grown on ECM protein-coated dishes showed more compact cellular morphology and CEC marker expression compared to cells seeded on uncoated dishes. Collectively, our results suggest that an adequate ECM protein combination can provide a long-term culture environment for HCECs for corneal endothelium transplantation. (paper)

  7. Cell Homogeneity Indispensable for Regenerative Medicine by Cultured Human Corneal Endothelial Cells.

    Science.gov (United States)

    Hamuro, Junji; Toda, Munetoyo; Asada, Kazuko; Hiraga, Asako; Schlötzer-Schrehardt, Ursula; Montoya, Monty; Sotozono, Chie; Ueno, Morio; Kinoshita, Shigeru

    2016-09-01

    To identify the subpopulation (SP) among heterogeneous cultured human corneal endothelial cells (cHCECs) devoid of cell-state transition applicable for cell-based therapy. Subpopulation presence in cHCECs was confirmed via surface CD-marker expression level by flow cytometry. CD markers effective for distinguishing distinct SPs were selected by analyzing those on established cHCECs with a small cell area and high cell density. Contrasting features among three typical cHCEC SPs was confirmed by PCR array for extracellular matrix (ECM). Combined analysis of CD markers was performed to identify the SP (effector cells) applicable for therapy. ZO-1 and Na+/K+ ATPase, CD200, and HLA expression were compared among heterogeneous SPs. Flow cytometry analysis identified the effector cell expressing CD166+CD105-CD44-∼+/-CD26-CD24-, but CD200-, and the presence of other SPs with CD166+ CD105-CD44+++ (CD26 and CD24, either + or -) was confirmed. PCR array revealed three distinct ECM expression profiles. Some SPs expressed ZO-1 and Na+/K+ ATPase at comparable levels with effector cells, while only one SP expressed CD200, but not on effector cells. Human leukocyte antigen expression was most reduced in the effector SP. The proportion of effector cells (E-ratio) inversely paralleled donor age and decreased during prolonged culture passages. The presence of Rho-associated protein kinase (ROCK) inhibitor increased the E-ratio in cHCECs. The average area of effector cells was approximately 200∼220 μm2, and the density of cHCECs exceeded 2500 cells/mm2. A specified cultured effector cell population sharing the surface phenotypes with mature HCECs in corneal tissues may serve as an alternative to donor corneas for the treatment of corneal endothelial dysfunction.

  8. Analysis of corneal endothelial cell density and morphology after laser in situ keratomileusis using two types of femtosecond lasers

    Directory of Open Access Journals (Sweden)

    Tomita M

    2012-09-01

    Full Text Available Minoru Tomita,1,2,* George O Waring IV,3,4 Miyuki Watabe,1,* 1Shinagawa LASIK Center, Chiyoda-ku, Tokyo, Japan; 2Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China; 3Medical University of South Carolina, Storm Eye Institute, Charleston, SC, USA; 4Magill Laser Center, Charleston, SC, USA*These authors contributed equally to this studyPurpose: To compare two different femtosecond lasers used for flap creation during laser-assisted in situ keratomileusis (LASIK surgery in terms of their effects on the corneal endothelium.Methods: We performed LASIK surgery on 254 eyes of 131 patients using IntraLase FS60 (Abbott Medical Optics, Inc, Irvine, CA; IntraLase group and 254 eyes of 136 patients using Femto LDV (Ziemer Group AG, Port, Switzerland; LDV group for corneal flap creation. The mean cell density, coefficient of variation, and hexagonality of the corneal endothelial cells were determined and the results were statistically compared.Results: There were no statistically significant differences in the corneal morphology between pre and post LASIK results in each group, nor were there significant differences between the results of both groups at 3 months post LASIK.Conclusions: Both IntraLase FS60 and Ziemer Femto LDV are able to create flaps without significant adverse effects on the corneal endothelial morphology through 3 months after LASIK surgery.Keywords: LASIK, corneal endothelium, femtosecond laser, IntraLase FS60, Ziemer LDV

  9. Effects of SOV-induced phosphatase inhibition and expression of protein tyrosine phosphatases in rat corneal endothelial cells.

    Science.gov (United States)

    Chen, Wei-Li; Harris, Deshea L; Joyce, Nancy C

    2005-11-01

    Contact inhibition is an important mechanism for maintaining corneal endothelium in a non-replicative state. Protein tyrosine phosphatases (PTPs) play a role in regulating the integrity of cell-cell contacts, differentiation, and growth. In this study, we aimed to evaluate whether phosphatases are involved in the maintenance of contact-dependent inhibition of proliferation in corneal endothelial cells and to identify candidate PTPs that are expressed in these cells and might be involved in regulation of contact inhibition. Confluent cultures of rat corneal endothelial cells or endothelium in ex vivo corneas were treated with the general phosphatase inhibitor, sodium orthovanadate (SOV). Immunocytochemistry (ICC) evaluated the effect of SOV on cell-cell contacts by staining for ZO-1, and on cell cycle progression by staining for Ki67. Transverse sections of rat cornea and cultured rat corneal endothelial cells were used to test for expression of the candidate PTPs: PTP-mu, PTP-LAR, PTP1B, SHP-1, SHP-2, and PTEN using ICC and either Western blots or RT-PCR. ZO-1 staining demonstrated that SOV induced a time-dependent release of cell-cell contacts in confluent cultures of corneal endothelial cells and in the endothelium of ex vivo corneas. Staining for Ki67 indicated that SOV promoted limited cell cycle progression in the absence of serum. PTP-mu, PTP1B, SHP-1, SHP-2, and PTEN, but not PTP-LAR, were expressed in rat corneal endothelial cells in situ and in culture. The subcellular location of PTP-mu and PTP1B differed in subconfluent and confluent cells, while that of SHP-1, SHP-2, and PTEN was similar, regardless of confluent status. Western blots confirmed the expression of PTP1B, SHP-1, SHP-2, and PTEN. RT-PCR confirmed expression of PTP-mu mRNA. Phosphatases are involved in regulation of junctional integrity and of cell proliferation in corneal endothelial cells. PTP-mu, PTP1B, SHP-1, SHP-2, and PTEN are expressed in rat corneal endothelium and may be involved in

  10. Human corneal endothelial cell transplantation using nanocomposite gel sheet in bullous keratopathy.

    Science.gov (United States)

    Parikumar, Periasamy; Haraguchi, Kazutoshi; Senthilkumar, Rajappa; Abraham, Samuel Jk

    2018-01-01

    Transplantation of in vitro expanded human corneal endothelial precursors (HCEP) cells using a nanocomposite (D25-NC) gel sheet as supporting material in bovine's cornea has been earlier reported. Herein we report the transplantation of HCEP cells derived from a cadaver donor cornea to three patients using the NC gel sheet. In three patients with bullous keratopathy, one after cataract surgery, one after trauma and another in the corneal graft, earlier performed for congenital corneal dystrophy, not amenable to medical management HCEP cells isolated from a human cadaver donor cornea in vitro expanded using a thermoreversible gelation polymer (TGP) for 26 days were divided into three equal portions and 1.6 × 10 5 HCEP cells were injected on to the endothelium of the affected eye in each patient using the D25-NC gel sheet as a supporting material. The sheets were removed after three days. The bullae in the cornea disappeared by the 3 rd -11 th post-operative day in all the three patients. Visual acuity improved from Perception of light (PL)+/Projection of rays (PR)+ to Hand movements (HM)+ in one of the patients by post-operative day 3 which was maintained at 18 months follow-up. At 18 months follow-up, in another patient the visual acuity had improved from HM+ to 6/60 while in the third patient, visual acuity remained HM+ as it was prior to HCEP transplantation. There were no adverse effects during the follow-up in any of the patients.

  11. SLC4A11 Prevents Osmotic Imbalance Leading to Corneal Endothelial Dystrophy, Deafness, and Polyuria*

    Science.gov (United States)

    Gröger, Nicole; Fröhlich, Henning; Maier, Hannes; Olbrich, Andrea; Kostin, Sawa; Braun, Thomas; Boettger, Thomas

    2010-01-01

    Maintenance of ion concentration gradients is essential for the function of many organs, including the kidney, the cornea, and the inner ear. Ion concentrations and fluid content in the cornea are regulated by endothelial cells that separate the collagenous avascular corneal stroma from the anterior eye chamber. Failure to maintain correct ion concentrations leads to swelling and destruction of the cornea. In the inner ear, the stria vascularis is responsible for generating proper ion concentrations in the endolymph, which is essential for hearing. Mutations of SLC4A11 in humans lead to syndromes associated with corneal dystrophy and perceptive deafness. The molecular mechanisms underlying these symptoms are poorly understood, impeding therapeutic interventions. The ion transporter SLC4A11 mediates sodium-dependent transport of borate as well as flux of sodium and hydroxyl ions in vitro. Here, we show that SLC4A11 is expressed in the endothelial cells of the cornea where it prevents severe morphological changes of the cornea caused by increased sodium chloride concentrations in the stroma. In the inner ear, SLC4A11 is located in fibrocytes underlying the stria vascularis. Loss of SLC4A11 leads to morphological changes in the fibrocytes and deafness. We demonstrate that SLC4A11 is essential for the generation of the endocochlear potential but not for regulation of potassium concentrations in the endolymph. In the kidney, SLC4A11 is expressed in the thin descending limb of Henle loop. SLC4A11 is essential for urinary concentration, suggesting that SLC4A11 participates in the countercurrent multiplication that concentrates urine in the kidney medulla. PMID:20185830

  12. Quantitative Assessment of Ultrastructure and Light Scatter in Mouse Corneal Debridement Wounds

    Science.gov (United States)

    Boote, Craig; Du, Yiqin; Morgan, Sian; Harris, Jonathan; Kamma-Lorger, Christina S.; Hayes, Sally; Lathrop, Kira L.; Roh, Danny S.; Burrow, Michael K.; Hiller, Jennifer; Terrill, Nicholas J.; Funderburgh, James L.; Meek, Keith M.

    2012-01-01

    Purpose. The mouse has become an important wound healing model with which to study corneal fibrosis, a frequent complication of refractive surgery. The aim of the current study was to quantify changes in stromal ultrastructure and light scatter that characterize fibrosis in mouse corneal debridement wounds. Methods. Epithelial debridement wounds, with and without removal of basement membrane, were produced in C57BL/6 mice. Corneal opacity was measured using optical coherence tomography, and collagen diameter and matrix order were quantified by x-ray scattering. Electron microscopy was used to visualize proteoglycans. Quantitative PCR (Q-PCR) measured mRNA transcript levels for several quiescent and fibrotic markers. Results. Epithelial debridement without basement membrane disruption produced a significant increase in matrix disorder at 8 weeks, but minimal corneal opacity. In contrast, basement membrane penetration led to increases in light scatter, matrix disorder, and collagen diameter, accompanied by the appearance of abnormally large proteoglycans in the subepithelial stroma. This group also demonstrated upregulation of several quiescent and fibrotic markers 2 to 4 weeks after wounding. Conclusions. Fibrotic corneal wound healing in mice involves extensive changes to collagen and proteoglycan ultrastructure, consistent with deposition of opaque scar tissue. Epithelial basement membrane penetration is a deciding factor determining the degree of ultrastructural changes and resulting opacity. PMID:22467580

  13. A study of corneal endothelial changes in soft contact lens wearers using non-contact specular microscopy

    Directory of Open Access Journals (Sweden)

    Renu M Magdum

    2013-01-01

    Full Text Available Aim: To study the corneal endothelial changes after soft contact lens wear, to correlate these changes with the duration of soft contact lens wear, and to study the pattern of use and preferences of contact lens among young adults. Materials and Methods: This observational study was carried out in 100 eyes of 50 soft contact lens users aged between 19 and 27 years. Both eyes of 50 medical students who had never worn contact lenses served as controls. Data from each subject were collected using a structured questionnaire of 24 items that included demographic profile, pattern of contact lens use, symptoms, brand name, number of years worn, and hours of daily wear. These data were analyzed using Chi square for association. Specular microscopy was done using TOPCON SP-3000P. Computerized morphometry was used to evaluate central corneal thickness, size, shape, mean cellular density, hexagonality, coefficient of variation, and polymegathism of the corneal cells . Results: It was found that central corneal thickness was 0.532 ± 0.0309 mm in lens users and 0.514 ± 0.03 mm in controls, cell density was 2570.91 ± 432.06 cells/mm 2 in lens users and 2723.17 ± 327.64 cells/mm 2 in controls, while hexagonality was 54.81 ± 39.72% in lens users and 67.65 ± 36.49% in controls. Conclusion: Despite the known effects of long duration of soft contact lens use on corneal endothelial cell morphology, this study could not draw a significant correlation between them. However, a significant difference was found in the corneal endothelial thickness, cell density, and hexagonality. Among the soft contact lens users, 62% used soft disposable type while 38% used soft extended wear contact lens. Contact lenses were preferred over spectacles for better cosmetic appearance, comfort, and wider visual field.

  14. Preparation of arginine–glycine–aspartic acid-modified biopolymeric nanoparticles containing epigalloccatechin-3-gallate for targeting vascular endothelial cells to inhibit corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Chang CY

    2016-12-01

    Full Text Available Che-Yi Chang,1,2,* Ming-Chen Wang,2,* Takuya Miyagawa,1 Zhi-Yu Chen,1 Feng-Huei Lin,3,4 Ko-Hua Chen,5,6 Guei-Sheung Liu,7 Ching-Li Tseng1 1Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, 2Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, 3Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan, 4Institute of Biomedical Engineering, National Taiwan University, 5Department of Ophthalmology, Taipei Veterans General Hospital, 6Department of Ophthalmology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan; 7Centre for Eye Research Australia, University of Melbourne, Royal Victorian Eye and Ear Hospital, East Melbourne, VIC, Australia *These authors contributed equally to this work Abstract: Neovascularization (NV of the cornea can disrupt visual function, causing ocular diseases, including blindness. Therefore, treatment of corneal NV has a high public health impact. Epigalloccatechin-3-gallate (EGCG, presenting antiangiogenesis effects, was chosen as an inhibitor to treat human vascular endothelial cells for corneal NV treatment. An arginine–glycine–aspartic acid (RGD peptide–hyaluronic acid (HA-conjugated complex coating on the gelatin/EGCG self-assembly nanoparticles (GEH-RGD NPs was synthesized for targeting the αvβ3 integrin on human umbilical vein endothelial cells (HUVECs in this study, and a corneal NV mouse model was used to evaluate the therapeutic effect of this nanomedicine used as eyedrops. HA-RGD conjugation via COOH and amine groups was confirmed by 1H-nuclear magnetic resonance and Fourier-transform infrared spectroscopy. The average diameter of GEH-RGD NPs was 168.87±22.5 nm with positive charge (19.7±2 mV, with an EGCG-loading efficiency up to 95%. Images of GEH-RGD NPs acquired from transmission electron microscopy showed a

  15. Corneal endothelial cell changes after cataract surgery in patients on systemic sympathetic α-1a antagonist medication (tamsulosin).

    Science.gov (United States)

    Storr-Paulsen, Allan; Jørgensen, Jesper Skovlund; Norregaard, Jens Christian; Thulesen, Jesper

    2014-06-01

      The purpose of this study was to assess the incidence of intraoperative floppy iris syndrome (IFIS) and the morphology of the corneal endothelium after cataract extraction in Caucasian male patients exposed to the α-1a adrenergic receptor antagonist tamsulosin.   In a clinical prospective study, 23 male patients (23 eyes) treated with tamsulosin due to benign prostatic hyperplasia and 25 male patients (25 eyes) with no tamsulosin treatment had cataract surgery. The divide-and-conquer technique was used with the Infinity OZil(®) machine. A combination of Healon and Healon5 was used in all patients, but the use of additional Vision Blue, iris retractors or intracameral phenylephrine in the tamsulosin group was at the discretion of the surgeon. The endothelial cell density, variation in endothelial cell size (CV), percentage of hexagonal cells and central corneal thickness (CCT) were recorded at baseline and at 3 months postoperatively.   In the tamsulosin-treated group, 19 of 23 eyes (83%) developed IFIS, compared with no IFIS in the control group. Compared with the control group, the tamsulosin group showed significantly less dilatation at the start of the operation, significant miosis during surgery and significantly greater corneal endothelial cell loss 3 months postoperatively (12% versus 3%; ptamsulosin-treated male patients. Patients on tamsulosin showed less preoperative dilatation, significant miosis during surgery, and had significantly greater postoperative endothelial cell loss compared with nontreated patients despite recommended precautions. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

  16. Changes in central corneal thickness and endothelial cell count pediatric cataract surgery

    International Nuclear Information System (INIS)

    Memon, M.N.

    2015-01-01

    To evaluate the mean changes in Central Corneal Thickness (CCT) and Endothelial Cell Count (ECC) in eyes after pediatric cataract surgery with foldable intraocular lens using scleral tunnel incision micro-surgical technique. Study Design: Qausi experimental study. Place and Duration of Study: Department of Pediatric Ophthalmology and Strabismus, Al-Shifa Trust Eye Hospital, Rawalpindi, from May 2011 to March 2012. Methodology: Fifty-two eyes of 37 children with pediatric cataract were included in the study. Extracapsular Cataract Extraction (ECE) with foldable Intra Ocular Lens (IOL) implantation using sclera tunnel incision was performed in all children. Endothelial Cell Count (ECC) and Central Corneal Thickness (CCT) were recorded before surgery and 1 month, 3 months and 6 months after surgery and the effect of currently practiced surgical technique on ECC and CCTwas evaluated. Results: The mean age at the time of surgery was 8.8 ± 2.7 years (range: 4 to 15 years). The postoperative ECC and CCT were significantly different from the pre-operative values. Mean pre-operative ECC was 3175.3 ± 218.4 cell/mm2 and in first postoperative month the mean ECC was 3113.4 ± 210.8 cell/mm2 (p<0.0001). In the 3rd and 6th month postoperative means ECC were 3052 ± 202.5 cell/mm2 (p<0.0001) and 3015 ±190.6 cell/mm2 (p<0.0001), respectively. The mean cell loss at first postoperative month was 1.95% and at 3rd and 6th postoperative month were 3.9% and 5.05%, respectively. Mean pre-operative CCT was 514 ± 49.9 micro m and first postoperative mean CCT after 1 month was 524.1 ± 25 micro m (p = 0.084). After the 3rd and 6th months postoperative, mean CCT were 527.3 ± 24.6 micro m, and 530 ± 24.5 micro m, respectively. Third and 6th months postoperative means were significantly higher than baseline CCT, p = 0.024 and 0.007, respectively. Conclusion: Endothelial cell loss with closed chamber micro-surgical technique using scleral tunnel incision is within acceptable limits and

  17. Characterization of cryopreserved primary human corneal endothelial cells cultured in human serum-supplemented media

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2016-02-01

    Full Text Available ABSTRACT Purpose: To compare cryopreserved human corneal endothelial cells (HCECs grown in human serum-supplemented media (HS-SM with cryopreserved HCECs grown in fetal bovine serum-supplemented media (FBS-SM. Methods: Three pairs of human corneas from donors aged 8, 28, and 31 years were obtained from the eye bank. From each pair, one cornea was used to start a HCEC culture using HS-SM; the other cornea was grown in FBS-SM. On reaching confluence, the six cell populations were frozen using 10% dimethyl sulfoxidecontaining medium. Thawed cells grown in HS-SM were compared with those grown in FBS-SM with respect to morphology, growth curves, immunohistochemistry, real time-reverse transcriptase polymerase chain reaction (RT-PCR for endothelial cell markers, and detachment time. Results: No difference in morphology was observed for cells grown in the two media before or after cryopreservation. By growth curves, cell counts after thawing were similar in both media, with a slight trend toward higher cell counts in FBS-SM. Cells grown in both the media demonstrated a similar expression of endothelial cell markers when assessed by immunohistochemistry, although HCEC marker gene expression was higher in cells grown in HS-SM than in those grown in FBS-SM as assessed by RT-PCR. With FBS-SM, there was a tendency of longer detachment time and lower cell passages. Conclusions: HS-SM was similar to FBS-SM for cryopreservation of cultured HCECs as assessed by analysis of cell morphology, proliferation, and protein expression, although marker gene expression was higher in cells grown in HS-SM than in those grown in FBS-SM. Detachment time was longer with FBS-SM and in lower passages.

  18. Ex vivo expansion of bovine corneal endothelial cells in xeno-free medium supplemented with platelet releasate.

    Directory of Open Access Journals (Sweden)

    Ming-Li Chou

    Full Text Available Clinical-grade ex vivo expansion of corneal endothelial cells can increase the availability of corneal tissues for transplantation and treatment of corneal blindness. However, these cells have very limited proliferative capacity. Successful propagation has required so far to use very complex growth media supplemented with fetal bovine serum and other xenocomponents. We hypothesized that human platelet releasates rich in multiple growth factors, and in particular neurotrophins, could potentially be a useful supplement for ex vivo expansion of corneal endothelium cells due to their neural crest origin. Platelet releasates were prepared by calcium salt activation of apheresis platelet concentrates, subjected or not to complement inactivation by heat treatment at 56°C for 30 minutes. Platelet releasates were characterized for their content in proteins and were found to contain high amount of growth factors including platelet-derived growth factor-AB (30.56 to 39.08 ng/ml and brain-derived neurotrophic factor (30.57 to 37.11 ng/ml neurotrophins. We compared the growth and viability of corneal endothelium cells in DMEM-F12 medium supplemented with different combinations of components, including 2.5%∼10% of the platelet releasates. Corneal endothelium cells expanded in platelet releasates exhibited good adhesion and a typical hexagonal morphology. Their growth and viability were enhanced when using the complement-inactivated platelet releasate at a concentration of 10%. Immunostaining and Western blots showed that CECs maintained the expressions of four important membrane markers: Na-K ATPase α1, zona occludens-1, phospho-connexin 43 and N-cadherin. In conclusion, our study provides the first proof-of-concept that human platelet releasates can be used for ex vivo expansion of corneal endothelium cells. These findings open a new paradigm for ex vivo propagation protocols of corneal endothelium cells in compliance with good tissue culture practices

  19. Effect of different culture media and deswelling agents on survival of human corneal endothelial and epithelial cells in vitro.

    Science.gov (United States)

    Valtink, Monika; Donath, Patricia; Engelmann, Katrin; Knels, Lilla

    2016-02-01

    To examine the effects of media and deswelling agents on human corneal endothelial and epithelial cell viability using a previously developed screening system. The human corneal endothelial cell line HCEC-12 and the human corneal epithelial cell line HCE-T were cultured in four different corneal organ culture media (serum-supplemented: MEM +2 % FCS, CorneaMax®/CorneaJet®, serum-free: Human Endothelial-SFM, Stemalpha-2 and -3) with and without 6 % dextran T500 or 7 % HES 130/0.4. Standard growth media F99HCEC and DMEM/F12HCE-T served as controls. In additional controls, the stress inducers staurosporine or hydrogen peroxide were added. After 5 days in the test media, cell viability was assessed by flow cytometrically quantifying apoptotic and necrotic cells (sub-G1 DNA content, vital staining with YO-PRO-1® and propidium iodide) and intracellular reactive oxygen species (ROS). The MEM-based media were unable to support HCEC-12 and HCE-T survival under stress conditions, resulting in significantly increased numbers of apoptotic and necrotic cells. HCEC-12 survival was markedly improved in SFM-based media even under staurosporine or hydrogen peroxide. Likewise, HCE-T survival was improved in SFM with or without dextran. The media CorneaMax®, CorneaJet®, and CorneaMax® with HES supported HCEC-12 survival better than MEM-based media, but less well than SFM-based media. HCE-T viability was also supported by CorneaJet®, but not by CorneaMax® with or without HES. Stemalpha-based media were not suitable for maintaining viability of HCEC-12 or HCE-T in the applied cell culture system. The use of serum-supplemented MEM-based media for corneal organ culture should be discontinued in favour of serum-free media like SFM.

  20. Cytotoxicity of ophthalmic solutions with and without preservatives to human corneal endothelial cells, epithelial cells and conjunctival epithelial cells.

    Science.gov (United States)

    Ayaki, Masahiko; Yaguchi, Shigeo; Iwasawa, Atsuo; Koide, Ryohei

    2008-08-01

    The cytotoxicity of a range of commercial ophthalmic solutions in the presence and absence of preservatives was assessed in human corneal endothelial cells (HCECs), corneal epithelia and conjunctival epithelia using in vitro techniques. Cell survival was measured using the WST-1 assay for endothelial cells and the MTT assay for epithelial cells. Commercially available timolol, carteolol, cromoglicate, diclofenac, bromfenac and hyaluronic acid ophthalmic solutions were assessed for cytotoxicity in the presence and absence of preservatives. The preservatives benzalkonium, chlorobutanol and polysorbate were also tested. The survival of cells exposed to test ophthalmic solutions was expressed as a percentage of cell survival in the control solution (distilled water added to media) after 48 h exposure. HCEC survival was 20-30% in ophthalmic solutions diluted 10-fold. The survival of HCEC was significantly greater in all solutions in the absence of preservative than in the presence of preservative. The survival of corneal and conjunctival epithelia was consistent with that of HCECs for all test ophthalmic solutions. The preservatives polysorbate and benzalkonium were highly cytotoxic with cell survival decreasing to 20% at the concentration estimated in commercial ophthalmic solutions. By comparison, the survival of cells exposed to chlorobutanol was 80% or greater. The cytotoxicity of ophthalmic solutions to HCEC, corneal epithelia and conjunctival epithelia decreased in the absence of preservative.

  1. Real-time assessment of corneal endothelial cell damage following graft preparation and donor insertion for DMEK.

    Directory of Open Access Journals (Sweden)

    Maninder Bhogal

    Full Text Available To establish a method for assessing graft viability, in-vivo, following corneal transplantation.Optimization of calcein AM fluorescence and toxicity assessment was performed in cultured human corneal endothelial cells and ex-vivo corneal tissue. Descemet membrane endothelial keratoplasty grafts were incubated with calcein AM and imaged pre and post preparation, and in-situ after insertion and unfolding in a pig eye model. Global, macroscopic images of the entire graft and individual cell resolution could be attained by altering the magnification of a clinical confocal scanning laser microscope. Patterns of cell loss observed in situ were compared to those seen using standard ex-vivo techniques.Calcein AM showed a positive dose-fluorescence relationship. A dose of 2.67μmol was sufficient to allow clear discrimination between viable and non-viable areas (sensitivity of 96.6% with a specificity of 96.1% and was not toxic to cultured endothelial cells or ex-vivo corneal tissue. Patterns of cell loss seen in-situ closely matched those seen on ex-vivo assessment with fluorescence viability imaging, trypan blue/alizarin red staining or scanning electron microscopy. Iatrogenic graft damage from preparation and insertion varied between 7-35% and incarceration of the graft tissue within surgical wounds was identified as a significant cause of endothelial damage.In-situ graft viability assessment using clinical imaging devices provides comparable information to ex-vivo methods. This method shows high sensitivity and specificity, is non-toxic and can be used to evaluate immediate cell viability in new grafting techniques in-vivo.

  2. Comparison of ultrasonic energy expenditures and corneal endothelial cell density reductions during modulated and non-modulated phacoemulsification.

    Science.gov (United States)

    Davison, James A

    2007-01-01

    To compare the Legacy 20000 Advantec continuous and Infiniti hyperpulse modes (Alcon Laboratories, Fort Worth, TX) with respect to average power, machine-measured phacoemulsification time, total stopwatch real time spent within the phacoemulsification process, balanced salt solution (BSS) volume, and corneal endothelial cell density losses. A background study was done of consecutive patients operated on with the Legacy (n = 60) and Infiniti (n = 40) machines programmed with identical parameters and using the continuous mode only. A primary study of another set of consecutive cases was operated on using the Legacy (n = 87) and Infiniti (n = 94) with the same parameters, but using the hyperpulse mode during quadrant removal with the Infiniti. Measurements for each set included average power and phacoemulsification time with corneal endothelial cell densities, BSS volume, and time spent in the phacoemulsification process. Similarities were found in the background study for average power percent and average minutes of phacoemulsification time. In the primary study, similarities were found for total minutes in the phacoemulsification process, BSS usage, and ECD losses, and differences were found for average power percent (PInfiniti performed similarly in continuous mode. With the Infiniti hyperpulse mode, a total ultrasonic energy reduction of 66% was noted. The machines required the same amount of total stopwatch measured time to accomplish phacoemulsification and produced the same 5% corneal endothelial cell loss. Therefore, clinically, these two machines behave in a comparable manner relative to safety and effectiveness.

  3. Effect of amniotic fluid on the in vitro culture of human corneal endothelial cells.

    Science.gov (United States)

    Feizi, Sepehr; Soheili, Zahra-Soheila; Bagheri, Abouzar; Balagholi, Sahar; Mohammadian, Azam; Rezaei-Kanavi, Mozhgan; Ahmadieh, Hamid; Samiei, Shahram; Negahban, Kambiz

    2014-05-01

    The present study was designed to evaluate the effects of human amniotic fluid (HAF) on the growth of human corneal endothelial cells (HCECs) and to establish an in vitro method for expanding HCECs. HCECs were cultured in DMEM-F12 supplemented with 20% fetal bovine serum (FBS). Confluent monolayer cultures were trypsinized and passaged using either FBS- or HAF-containing media. Cell proliferation and cell death ELISA assays were performed to determine the effect of HAF on cell growth and viability. The identity of the cells cultured in 20% HAF was determined using immunocytochemistry (ICC) and real-time reverse transcription polymerase chain reaction (RT-PCR) techniques to evaluate the expression of factors that are characteristic of HCECs, including Ki-67, Vimentin, Na+/K+-ATPase and ZO-1. HCEC primary cultures were successfully established using 20% HAF-containing medium, and these cultures demonstrated rapid cell proliferation according to the cell proliferation and death ELISA assay results. The ICC and real time RT-PCR results indicated that there was a higher expression of Na+/K+-ATPase and ZO-1 in the 20% HAF cell cultures compared with the control (20% FBS) (P < 0.05). The 20% HAF-containing medium exhibited a greater stimulatory effect on HCEC growth and could represent a potential enriched supplement for HCEC regeneration studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Transforming growth factor-β2 induces morphological alteration of human corneal endothelial cells in vitro

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2014-10-01

    Full Text Available AIM:To investigate the morphological altering effect of transforming growth factor-β2 (TGF-β2 on untransfected human corneal endothelial cells (HCECs in vitro.METHODS: After untransfected HCECs were treated with TGF-β2 at different concentrations, the morphology, cytoskeleton distribution, and type IV collagen expression of the cells were examined with inverted contrast light microscopy, fluorescence microscopy, immunofluorescence or Western Blot.RESULTS:TGF-β2 at the concentration of 3-15 μg/L had obviously alterative effects on HCECs morphology in dose and time-dependent manner, and 9 μg/L was the peak concentration. TGF-β2 (9 μg/L altered HCE cell morphology after treatment for 36h, increased the mean optical density (P<0.01 and the length of F-actin, reduced the mean optical density (P<0.01 of the collagen type IV in extracellular matrix (ECM and induced the rearrangement of F-actin, microtubule in cytoplasm and collagen type IV in ECM after treatment for 72h. CONCLUTION:TGF-β2 has obviously alterative effect on the morphology of HCECs from polygonal phenotype to enlarged spindle-shaped phenotype, in dose and time-dependence manner by inducing more, elongation and alignment of F-actin, rearrangement of microtubule and larger spread area of collagen type IV.

  5. Serial corneal endothelial cell loss with lathe-cut and injection-molded posterior chamber intraocular lenses.

    Science.gov (United States)

    Kraff, M C; Sanders, D R; Lieberman, H L

    1983-01-01

    We compared endothelial cell loss of patients implanted with lathe-cut posterior chamber lenses and those implanted with injection-molded lenses over a three-year postoperative period. Results were based on more than 2,500 measurements of corneal endothelial density. Although the technique of cataract extraction (anterior chamber phacoemulsification, posterior chamber phacoemulsification, or planned extracapsular extraction) significantly affected cell loss (P less than .01), the type of implant (lathe-cut or injection-molded) did not. Significant continuing endothelial cell loss did not occur during the first three postoperative years with injection-molded lenses. There was, however, a statistically significant 7% to 15% additional cell loss after surgery over the first two to three postoperative years with lathe-cut implants. There have been no cases of corneal endothelial decompensation developing after implantation of injection-molded or lathe-cut lenses. Because a standard field clinical specular microscope was used in this study, cell counting errors cannot be ruled out as a cause of these findings.

  6. Characterization of bicarbonate-dependent potassium uptake in cultured corneal endothelial cells

    International Nuclear Information System (INIS)

    Savion, N.; Farzame, N.; Berlin, H.B.

    1989-01-01

    Bovine corneal endothelial (BCE) cells in culture demonstrated 86Rb+ uptake which was mostly ouabain-sensitive with some (15 to 50%) ouabain-insensitive uptake that was dependent on the presence of bicarbonate in the incubation medium. Bovine smooth muscle (SM) cells demonstrated ouabain-sensitive 86Rb+ uptake but the ouabain-insensitive 86Rb+ uptake was not bicarbonate-dependent. Although omission of bicarbonate from the incubation buffer resulted in some reduction in the pH, this change was not responsible for the reduction in the ouabain-insensitive 86Rb+ uptake. Furthermore, the removal of bicarbonate decreased the 86Rb+ influx but not its efflux. This ouabain-insensitive and bicarbonate-dependent 86Rb+ influx in BCE cells proceeded at a linear rate for at least 60 min and increased as a function of bicarbonate concentration such that almost maximal uptake was observed at a concentration of about 10 to 15 mM. Saturation of the bicarbonate-dependent 86Rb+ pump in BCE cells occurred at a concentration of 2 mM Rb+ in the incubation buffer, similar to the previously observed value for the Na+, K+-ATPase. Competition experiments with both unlabeled Rb+ and K+ demonstrated that likewise in the Na+, K+-ATPase the 86Rb+ influx represented physiological influx of K+. Furthermore, the energy requirements of the bicarbonate-dependent 86Rb+ uptake were similar to those of the 86Rb+ uptake via the Na+, K+-ATPase. The results described in this work demonstrated a novel bicarbonate-dependent K+ pump in addition to the Na+, K+-ATPase pump.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    Science.gov (United States)

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  8. Accuracy of Corneal Thickness by Swept-Source Optical Coherence Tomography and Scheimpflug Camera in Virgin and Treated Fuchs Endothelial Dystrophy.

    Science.gov (United States)

    Arnalich-Montiel, Francisco; Ortiz-Toquero, Sara; Auladell, Clara; Couceiro, Ana

    2018-06-01

    To assess intraobserver repeatability, intersession reproducibility, and agreement of swept-source Fourier-domain optical coherence tomography (SS-OCT) and the Scheimpflug camera in measuring corneal thickness in virgin and grafted eyes with Fuchs endothelial corneal dystrophy (FECD). Thirty-six control eyes, 35 FECD eyes, 30 FECD with corneal edema eyes, 25 Descemet stripping automated endothelial keratoplasty (DSAEK) eyes, and 29 Descemet membrane endothelial keratoplasty (DMEK) eyes were included. The apical center, pupillary center, and thinnest corneal thickness were determined in 3 consecutive images and repeated 2 weeks later. Repeatability and reproducibility coefficients, intraclass correlation coefficients, and 95% limits of agreement (LOA) between measurements were calculated. Agreement between devices was assessed using Bland-Altman analysis. Corneal thickness measurements were highly reproducible and repeatable with both systems. SS-OCT showed better repeatability in all corneal locations in the normal, FECD, FECD with edema, DSAEK, and DMEK groups (coefficient of variation ≤0.60%, ≤0.36%, ≤0.43%, ≤1.09%, and ≤0.48%, respectively) than the Scheimpflug (coefficient of variation ≤1.15%, ≤0.92%, ≤1.10%, ≤1.25%, and ≤1.14%, respectively). Between-session 95% LOA for SS-OCT was less than 3% for all groups except for the FECD with edema group, being almost double using the Scheimpflug camera. Differences between instruments were statistically significant in all groups and locations (P group (P ≤ 0.51); however, SS-OCT underestimated all measurements. SS-OCT provides better reproducible and repeatable measurements of corneal thickness than those obtained with the Scheimpflug camera in patients with FECD or an endothelial transplant. Variations between examinations higher than the 95% LOA observed in our study should raise awareness of changes in the endothelial function.

  9. Corneal endothelial cell density after femtosecond thin-flap LASIK and PRK for myopia: a contralateral eye study.

    Science.gov (United States)

    Smith, Ryan T; Waring, George O; Durrie, Daniel S; Stahl, Jason E; Thomas, Priscilla

    2009-12-01

    To compare the effect of femtosecond thinflap LASIK and photorefractive keratectomy (PRK) on postoperative endothelial cell density. In a prospective, randomized, contralateral, single-center clinical trial, 25 patients (mean age: 30+/-5 years [range: 21 to 38 years]) underwent PRK in one eye and thin-flap LASIK in the fellow eye for the correction of myopia using a wavefront-guided platform. The central corneal endothelial cell density was measured using the NIDEK Confoscan 4 preoperatively, and at 1 and 3 months postoperatively. Changes in endothelial cell density were analyzed over time between the two refractive techniques. In PRK, the average preoperative endothelial cell density was 3011+/-329 cells/mm(2), which decreased to 2951+/-327 cells/mm(2) at 1 month (P=.5736) and 2982+/-365 cells/mm(2) at 3 months (P=.6513). In thinflap LASIK, the average preoperative endothelial cell density was 2995+/-325 cells/mm(2), which decreased to 2977+/-358 cells/mm(2) at 1 month (P=.5756) and 2931+/-369 cells/mm(2) at 3 months (P=.4106). No statistically significant difference was found between the two groups at 1 (P=.7404) or 3 (P=.3208) months postoperatively. No statistically significant change was noted in endothelial cell density following either PRK or thin-flap LASIK for the treatment of myopia. Furthermore, no statistically significant difference was found between the two groups out to 3 months postoperatively, indicating that thin-flap LASIK is as safe as PRK with regards to endothelial health.

  10. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis.

    Science.gov (United States)

    Kalinina Ayuso, Viera; Scheerlinck, Laura M; de Boer, Joke H

    2013-03-01

    To assess the effect of Ahmed glaucoma valve implants on corneal endothelial cell density (ECD) in children with uveitic glaucoma. Cross-sectional study. setting: Institutional. patientpopulation: Eighty eyes from 42 patients diagnosed with uveitis before the age of 16. Twenty-eight eyes had an Ahmed glaucoma valve implant because of secondary glaucoma. Fifty-two eyes without an implant served as controls. intervention orobservationprocedure(s): Corneal ECD was examined cross-sectionally using a noncontact specular microscope. Univariate and multivariate generalized estimating equations analyses with correction for paired eyes were performed. mainoutcomemeasure(s): Correlation of ECD with the presence of an Ahmed glaucoma valve implant and with the time following implantation. ECD was significantly lower in the Ahmed glaucoma valve group than in controls (2359 and 3088 cells/mm(2), respectively; P Ahmed glaucoma valve implantation. Presence of an Ahmed glaucoma valve implant, previous intraocular surgery, age, duration of uveitis, and history of corneal touch by the implant tube were all significantly associated with decreased ECD. Following a multivariate analysis, presence of an Ahmed glaucoma valve implant (B = -340; adjusted P Ahmed glaucoma valve implantation was highly correlated with decreased ECD (B = -558, P Ahmed glaucoma valve implants in children with uveitic glaucoma are independently associated with decreased ECD, and this effect is associated with the time interval following Ahmed glaucoma valve implantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Protein tyrosine phosphatase, PTP1B, expression and activity in rat corneal endothelial cells

    Science.gov (United States)

    Harris, Deshea L.

    2007-01-01

    Purpose The current studies were conducted to determine whether the protein tyrosine phosphatase, PTP1B, plays a role in regulating epidermal growth factor receptor (EGFR) Tyr992 phosphorylation and cell cycle entry in rat corneal endothelial cells. Methods Corneas were obtained from male Sprague-Dawley rats. PTP1B mRNA and protein expression were compared in confluent and subconfluent cells by RT-PCR and western blots. Immunocytochemistry was used to determine the subcellular localization of both PTP1B and EGFR following epidermal growth factor (EGF) stimulation. Western blots were used to analyze the time-dependent effect of EGF on phosphorylation of EGFR Tyr992 plus or minus CinnGEL 2Me, an inhibitor of PTP1B activity. The effect of PTP1B inhibition on cell cycle entry was determined by calculating the percent of Ki67-positive cells following EGF treatment. Results PTP1B mRNA expression was similar in confluent and subconfluent cells, but PTP1B protein was expressed at 3 fold higher levels in subconfluent cells. Positive staining for PTP1B was localized in vesicular structures below the plasma membrane. EGFR staining was located at cell-cell borders in untreated endothelium, but was mainly cytoplasmic by 15 min after EGF treatment. In control cultures, phosphorylation of EGFR Tyr992 peaked by 5 min following EGF stimulation and rapidly decreased to basal levels by 30 min. In cultures pretreated with CinnGEL 2Me, Tyr992 phosphorylation peaked 2 min following EGF addition and was consistently sustained at a higher level than controls until 60 min after treatment. By 18 h following EGF treatment, cultures pretreated with CinnGEL 2Me exhibited a 1.7 fold increase in the number of Ki67-positive cells compared with control cultures. Conclusions Comparison of PTP1B mRNA and protein levels indicates that PTP1B expression is regulated mainly at the protein level and is higher in subconfluent cells. PTP1B was located in vesicles below the plasma membrane. The fact that

  12. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope.

    Science.gov (United States)

    Doughty, M J; Müller, A; Zaman, M L

    2000-03-01

    We sought to determine the variance in endothelial cell density (ECD) estimates for human corneal endothelia. Noncontact specular micrographs were obtained from white subjects without any history of contact lens wear, or major eye disease or surgery; subjects were within four age groups (children, young adults, older adults, senior citizens). The endothelial image was scanned, and the areas from > or =75 cells measured from an overlay by planimetry. The cell-area values were used to calculate the ECD repeatedly so that the intra- and intersubject variation in an average ECD estimate could be made by using different numbers of cells (5, 10, 15, etc.). An average ECD of 3,519 cells/mm2 (range, 2,598-5,312 cells/mm2) was obtained of counts of 75 cells/ endothelium from individuals aged 6-83 years. Average ECD estimates in each age group were 4,124, 3,457, 3,360, and 3,113 cells/mm2, respectively. Analysis of intersubject variance revealed that ECD estimates would be expected to be no better than +/-10% if only 25 cells were measured per endothelium, but approach +/-2% if 75 cells are measured. In assessing the corneal endothelium by noncontact specular microscopy, cell count should be given, and this should be > or =75/ endothelium for an expected variance to be at a level close to that recommended for monitoring age-, stress-, or surgery-related changes.

  13. Changes in Corneal Endothelial Cell after Ahmed Glaucoma Valve Implantation and Trabeculectomy: 1-Year Follow-up.

    Science.gov (United States)

    Kim, Min Su; Kim, Kyoung Nam; Kim, Chang-Sik

    2016-12-01

    To compare changes in corneal endothelial cell density (CECD) after Ahmed glaucoma valve (AGV) implantation and trabeculectomy. Changes in corneal endothelium in patients that underwent AGV implantation or trabeculectomy were prospectively evaluated. Corneal specular microscopy was performed at the central cornea using a non-contact specular microscope before surgery and 6 months and 12 months after surgery. The CECD, hexagonality of the endothelial cells, and the coefficient of variation of the cell areas were compared between the two groups. Forty eyes of 40 patients with AGV implantation and 28 eyes of 28 patients with trabeculectomy were studied. Intraocular pressure in the AGV implantation group was significantly higher than that in the trabeculectomy group ( p < 0.001), but there was no significant difference in other clinical variables between the two groups. In the AGV implantation group, the mean CECD significantly decreased by 9.4% at 6 months and 12.3% at 12 months compared with baseline values (both, p < 0.001), while it decreased by 1.9% at 6 months and 3.2% at 12 months in the trabeculectomy group ( p = 0.027 and p = 0.015, respectively). The changes at 6 months and 12 months in the AGV implantation group were significantly higher than those in the trabeculectomy group ( p = 0.030 and p = 0.027, respectively). In the AGV implantation group, there was a significant decrease in the CECD between baseline and 6 months and between 6 months and 12 months ( p < 0.001 and p = 0.005, respectively). However, in the trabeculectomy group, a significant decrease was observed only between baseline and 6 months ( p = 0.027). Both the AGV implantation group and the trabeculectomy group showed statistically significant decreases in the CECD 1 year after surgery. The decrease in CECD in the AVG implantation group was greater and persisted longer than that in the trabeculectomy group.

  14. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-10-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur.

  15. Menadione-Induced DNA Damage Leads to Mitochondrial Dysfunction and Fragmentation During Rosette Formation in Fuchs Endothelial Corneal Dystrophy.

    Science.gov (United States)

    Halilovic, Adna; Schmedt, Thore; Benischke, Anne-Sophie; Hamill, Cecily; Chen, Yuming; Santos, Janine Hertzog; Jurkunas, Ula V

    2016-06-20

    Fuchs endothelial corneal dystrophy (FECD), a leading cause of age-related corneal edema requiring transplantation, is characterized by rosette formation of corneal endothelium with ensuing apoptosis. We sought to determine whether excess of mitochondrial reactive oxygen species leads to chronic accumulation of oxidative DNA damage and mitochondrial dysfunction, instigating cell death. We modeled the pathognomonic rosette formation of postmitotic corneal cells by increasing endogenous cellular oxidative stress with menadione (MN) and performed a temporal analysis of its effect in normal (HCEnC, HCECi) and FECD (FECDi) cells and ex vivo specimens. FECDi and FECD ex vivo specimens exhibited extensive mtDNA and nDNA damage as detected by quantitative PCR. Exposure to MN triggered an increase in mitochondrial superoxide levels and led to mtDNA and nDNA damage, while DNA amplification was restored with NAC pretreatment. Furthermore, MN exposure led to a decrease in ΔΨm and adenosine triphosphate levels in normal cells, while FECDi exhibited mitochondrial dysfunction at baseline. Mitochondrial fragmentation and cytochrome c release were detected in FECD tissue and after MN treatment of HCEnCs. Furthermore, cleavage of caspase-9 and caspase-3 followed MN-induced cytochrome c release in HCEnCs. This study provides the first line of evidence that accumulation of oxidative DNA damage leads to rosette formation, loss of functionally intact mitochondria via fragmentation, and subsequent cell death during postmitotic cell degeneration of ocular tissue. MN induced rosette formation, along with mtDNA and nDNA damage, mitochondrial dysfunction, and fragmentation, leading to activation of the intrinsic apoptosis via caspase cleavage and cytochrome c release. Antioxid. Redox Signal. 24, 1072-1083.

  16. [Management of corneal endothelial decompensation with Descemet's membrane endothelial keratoplasty in a patient with Ahmed glaucoma valve implant].

    Science.gov (United States)

    Röck, T; Bartz-Schmidt, K-U; Röck, D; Yoeruek, E

    2014-05-01

    Currently, the main causes for developing bullous keratopathy are from problems related to intraocular surgery, trauma, infection, Fuchs' endothelial dystrophy and chronically elevated intraocular pressure. In the 1990s penetrating keratoplasty was once considered the therapy of choice for treatment of bullous keratopathy but in recent years it has been replaced by posterior lamellar keratoplasty. The Descemet membrane endothelial keratoplasty (DMEK) procedure represents the final development of posterior lamellar keratoplasty. The question now arises whether DMEK can be used in patients with bullous keratopathy and Ahmed glaucoma valve implant. A 72-year-old man was referred to our hospital for further evaluation with the diagnosis of bullous keratopathy and pseudoexfoliative glaucoma. The bullous keratopathy was caused by a variety of previous operations as well as decompensation of intraocular pressure. This article describes the therapy of bullous keratopathy by DMEK with existing Ahmed glaucoma valve implant. After surgery the cornea became clear and the best-corrected visual acuity improved from hand movement to 0.2. The intraocular pressure remained normal (10-14 mmHg) without antiglaucoma medication and the endothelial cell count decreased only slightly over a follow-up of 13 months. No complications were encountered. The DMEK surgical procedure seems to be possible in patients with Ahmed glaucoma valve implant and endothelial decompensation. However, further studies with a larger number of patients should follow to validate the replacement of penetrating keratoplasty and other posterior lamellar procedures by DMEK.

  17. Methods Development for the Isolation and Culture of Primary Corneal Endothelial Cells

    Science.gov (United States)

    2017-02-01

    purposes of advertisement . REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of...widespread stockpiling and the lack of definitive medical treatment. The vast majority of SM exposure cases involve corneal injury. At low-exposure doses

  18. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-01-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur. Images PMID:6615750

  19. Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines.

    Science.gov (United States)

    Ataş, Mustafa; Demircan, Süleyman; Karatepe Haşhaş, Arzu Seyhan; Gülhan, Ahmet; Zararsız, Gökmen

    2014-01-01

    To compare and evaluate the phacoemulsification parameters and postoperative endothelial cell changes of two different phacoemulsification machines, each with different modes, but also to assess the relationship between postoperative endothelial cell loss and the phacoemulsification parameters, as well as the other factors in both groups. This prospective observational study was comprised of consecutive eligible cataract patients operated with phacoemulsification technique performed by the same surgeon using either a WHITESTAR Signature Ellips FX (transversal, group 1) or Infiniti OZil IP (torsional, group 2) machine. The study included 86 patients. Baseline characteristics in the groups were similar. The median nuclear sclerosis grade was 3 (2-4) in the first group and 2 (2-4) in the second group (P=0.265). Both groups had similar phacoemulsification needle times (group 1: 60.63±36 s; group 2: 55.98±30 s; P=0.789). The percentage of endothelial cell loss 30d after surgery ranged from 3% to 15% with a median of 7% in group 1, and from 2% to 13% with a median of 6% in group 2; however, there was no statistically significant difference between the groups (P=0.407). Hexagonality (P=0.794) and the coefficient of variation (CV; P=0.142) did not differ significantly between the groups before and 30d after surgery. A significant positive correlation was found between the endothelial cell loss and nuclear sclerosis grade (group 1: P<0.001; group 2: P<0.001) and between the endothelial cell loss and average phacoemulsification power (group 1: P=0.007; group 2: P=0.008). Both of these machines were efficient, with similar endothelial cell loss. This endothelial cell loss was related to the increased nuclear sclerosis grade and increased phacoemulsification power.

  20. An optimized method for mouse liver sinusoidal endothelial cell isolation

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Jeremy, E-mail: jeremy.meyer@hcuge.ch [Division of Digestive and Transplantation Surgery, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Genève 14 (Switzerland); Unit of Surgical Research, University of Geneva, Rue Michel-Servet 1, 1206 Genève (Switzerland); Lacotte, Stéphanie, E-mail: stephanie.lacotte@unige.ch [Unit of Surgical Research, University of Geneva, Rue Michel-Servet 1, 1206 Genève (Switzerland); Morel, Philippe, E-mail: philippe.morel@hcuge.ch [Division of Digestive and Transplantation Surgery, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Genève 14 (Switzerland); Unit of Surgical Research, University of Geneva, Rue Michel-Servet 1, 1206 Genève (Switzerland); Gonelle-Gispert, Carmen, E-mail: carmen.gonelle@unige.ch [Unit of Surgical Research, University of Geneva, Rue Michel-Servet 1, 1206 Genève (Switzerland); Bühler, Léo, E-mail: leo.buhler@hcuge.ch [Division of Digestive and Transplantation Surgery, University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, 1211 Genève 14 (Switzerland); Unit of Surgical Research, University of Geneva, Rue Michel-Servet 1, 1206 Genève (Switzerland)

    2016-12-10

    The objective of the present study was to develop an accurate and reproducible method for liver sinusoidal endothelial cell (LSEC) isolation in mice. Non-parenchymal cells were isolated using a modified two-step collagenase digestion combined with Optiprep density gradient centrifugation. LSEC were further purified using two prevalent methods, short-term selective adherence and CD146+ magnetic-activated cell sorting (MACS), and compared in terms of cell yield, viability and purity to our purification technique using CD11b cell depletion combined with long-term selective adherence. LSEC purification using our technique allowed to obtain 7.07±3.80 million LSEC per liver, while CD146+ MACS and short-term selective adherence yielded 2.94±1.28 and 0.99±0.66 million LSEC, respectively. Purity of the final cell preparation reached 95.10±2.58% when using our method. In contrast, CD146+ MACS and short-term selective adherence gave purities of 86.75±3.26% and 47.95±9.82%, respectively. Similarly, contamination by non-LSEC was the lowest when purification was performed using our technique, with a proportion of contaminating macrophages of only 1.87±0.77%. Further, isolated cells analysed by scanning electron microscopy presented typical LSEC fenestrations organized in sieve plates, demonstrating that the technique allowed to isolate bona fide LSEC. In conclusion, we described a reliable and reproducible technique for the isolation of high yields of pure LSEC in mice. This protocol provides an efficient method to prepare LSEC for studying their biological functions. - Highlights: • This protocol provides an efficient method to prepare primary mouse LSEC for studying their biological functions. • The liver cell dispersion step was improved by performing a retrograde cannulation of the liver. • The cell yield and the purity obtained were higher than comparative techniques in mice. • Contaminating macrophages were removed by introducing a CD11b- magnetic

  1. An optimized method for mouse liver sinusoidal endothelial cell isolation

    International Nuclear Information System (INIS)

    Meyer, Jeremy; Lacotte, Stéphanie; Morel, Philippe; Gonelle-Gispert, Carmen; Bühler, Léo

    2016-01-01

    The objective of the present study was to develop an accurate and reproducible method for liver sinusoidal endothelial cell (LSEC) isolation in mice. Non-parenchymal cells were isolated using a modified two-step collagenase digestion combined with Optiprep density gradient centrifugation. LSEC were further purified using two prevalent methods, short-term selective adherence and CD146+ magnetic-activated cell sorting (MACS), and compared in terms of cell yield, viability and purity to our purification technique using CD11b cell depletion combined with long-term selective adherence. LSEC purification using our technique allowed to obtain 7.07±3.80 million LSEC per liver, while CD146+ MACS and short-term selective adherence yielded 2.94±1.28 and 0.99±0.66 million LSEC, respectively. Purity of the final cell preparation reached 95.10±2.58% when using our method. In contrast, CD146+ MACS and short-term selective adherence gave purities of 86.75±3.26% and 47.95±9.82%, respectively. Similarly, contamination by non-LSEC was the lowest when purification was performed using our technique, with a proportion of contaminating macrophages of only 1.87±0.77%. Further, isolated cells analysed by scanning electron microscopy presented typical LSEC fenestrations organized in sieve plates, demonstrating that the technique allowed to isolate bona fide LSEC. In conclusion, we described a reliable and reproducible technique for the isolation of high yields of pure LSEC in mice. This protocol provides an efficient method to prepare LSEC for studying their biological functions. - Highlights: • This protocol provides an efficient method to prepare primary mouse LSEC for studying their biological functions. • The liver cell dispersion step was improved by performing a retrograde cannulation of the liver. • The cell yield and the purity obtained were higher than comparative techniques in mice. • Contaminating macrophages were removed by introducing a CD11b- magnetic

  2. Organ culture storage of pre-prepared corneal donor material for Descemet's membrane endothelial keratoplasty.

    Science.gov (United States)

    Bhogal, Maninder; Matter, Karl; Balda, Maria S; Allan, Bruce D

    2016-11-01

    To evaluate the effect of media composition and storage method on pre-prepared Descemet's membrane endothelial keratoplasty (DMEK) grafts. 50 corneas were used. Endothelial wound healing and proliferation in different media were assessed using a standard injury model. DMEK grafts were stored using three methods: peeling with free scroll storage; partial peeling with storage on the stroma and fluid bubble separation with storage on the stroma. Endothelial cell (EC) phenotype and the extent of endothelial overgrowth were examined. Global cell viability was assessed for storage methods that maintained a normal cell phenotype. 1 mm wounds healed within 4 days. Enhanced media did not increase EC proliferation but may have increased EC migration into the wounded area. Grafts that had been trephined showed evidence of EC overgrowth, whereas preservation of a physical barrier in the bubble group prevented this. In grafts stored in enhanced media or reapposed to the stroma after trephination, endothelial migration occurred sooner and cells underwent endothelial-mesenchymal transformation. Ongoing cell loss, with new patterns of cell death, was observed after returning grafts to storage. Grafts stored as free scrolls retained more viable ECs than grafts prepared with the fluid bubble method (74.2± 3% vs 60.3±6%, p=0.04 (n=8). Free scroll storage is superior to liquid bubble and partial peeling techniques. Free scrolls only showed overgrowth of ECs after 4 days in organ culture, indicating a viable time window for the clinical use of pre-prepared DMEK donor material using this method. Methods for tissue preparation and storage media developed for whole corneas should not be used in pre-prepared DMEK grafts without prior evaluation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Effect of laser peripheral iridotomy using argon and neodymium-YAG lasers on corneal endothelial cell density: 7-year longitudinal evaluation.

    Science.gov (United States)

    Ono, Takashi; Iida, Masaharu; Sakisaka, Toshihiro; Minami, Keiichiro; Miyata, Kazunori

    2018-03-01

    To evaluate the changes in corneal endothelial cell density (ECD) over a 7-year period after laser peripheral iridotomy (LPI) using argon and neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers. Retrospective case series. Eyes that underwent prophylactic LPI using argon and Nd:YAG lasers were followed up for 7 years. Central corneal endothelial cells were observed by use of noncontact specular microscopy preoperatively and at 1 and 7 years postoperatively. Changes in ECD and the associations between preoperative ECD and the total energy of the Nd:YAG laser were evaluated. Fifty-one eyes of 51 patients were followed up for 7 years. The ECD significantly decreased after LPI (P laser energy. Long-term evaluation indicated that the reduction in ECD after argon-Nd:YAG laser LPI was present but small during the initial year and was negligible after 1 year.

  4. Replication of TCF4 through association and linkage studies in late-onset Fuchs endothelial corneal dystrophy.

    Directory of Open Access Journals (Sweden)

    Yi-Ju Li

    Full Text Available Fuchs endothelial corneal dystrophy (FECD is a common, late-onset disorder of the corneal endothelium. Although progress has been made in understanding the genetic basis of FECD by studying large families in which the phenotype is transmitted in an autosomal dominant fashion, a recently reported genome-wide association study identified common alleles at a locus on chromosome 18 near TCF4 which confer susceptibility to FECD. Here, we report the findings of our independent validation study for TCF4 using the largest FECD dataset to date (450 FECD cases and 340 normal controls. Logistic regression with sex as a covariate was performed for three genetic models: dominant (DOM, additive (ADD, and recessive (REC. We found significant association with rs613872, the target marker reported by Baratz et al.(2010, for all three genetic models (DOM: P = 9.33×10(-35; ADD: P = 7.48×10(-30; REC: P = 5.27×10(-6. To strengthen the association study, we also conducted a genome-wide linkage scan on 64 multiplex families, composed primarily of affected sibling pairs (ASPs, using both parametric and non-parametric two-point and multipoint analyses. The most significant linkage region localizes to chromosome 18 from 69.94cM to 85.29cM, with a peak multipoint HLOD = 2.5 at rs1145315 (75.58cM under the DOM model, mapping 1.5 Mb proximal to rs613872. In summary, our study presents evidence to support the role of the intronic TCF4 single nucleotide polymorphism rs613872 in late-onset FECD through both association and linkage studies.

  5. Comparison of mean corneal endothelial cell loss after trabeculectomy with and without mitomycin C

    International Nuclear Information System (INIS)

    Shaheer, M.; Amjad, A.; Ahmed, N.

    2018-01-01

    Objective:To compare mean endothelial cell loss in patients of primary open angle glaucoma undergoing trabeculectomy with and without mitomycin C. Study Design:Randomised control study. Place and Duration of Study:Institute of Ophthalmology, Mayo Hospital, Lahore, from May 2016 to April 2017. Methodology:Patients with primary open angle glaucoma, not controlled with medication, were selected from the outpatient department. Patients with secondary glaucomas and concomitant ocular disease were excluded. Selected patients were divided into two groups of 30 each. Group A patients underwent trabeculectomy with adjunctive mitomycin C while group B patients underwent trabeculectomy alone. Pre- and post-trabeculectomy endothelial cell counts were recorded with the help of specular microsope and entered on proforma. Results:Median cell loss was 283 (66.50) when trabeculectomy was done with the use of adjunctive mitomycin C in group A while median endothelial cell loss was 72.50 (19.25) when the trabeculectomy was done without the use of adjunctive mitomycin C in group B. Conclusion:Use of mitomycin C causes more endothelial cell loss during trabeculectomy as compared to when done without it. (author)

  6. Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

    Science.gov (United States)

    Karaca, Irmak; Yilmaz, Suzan Guven; Palamar, Melis; Ates, Halil

    2017-07-03

    To investigate the correlation of Scheimpflug camera system and two noncontact specular microscopes in terms of central corneal thickness (CCT) and corneal endothelial cell morphology measurements. One hundred eyes of 50 healthy subjects were examined by Pentacam Scheimpflug Analyzer, CEM-530 (Nidek Co, Ltd, Gamagori, Japan) and CellChek XL (Konan Medical, California, USA) via fully automated image analysis with no corrections made. Measurement differences and agreement between instruments were determined by intraclass correlation analysis. The mean age of the subjects was 36.74 ± 8.59 (range 22-57). CCTs were well correlated among all devices, with having CEM-530 the thinnest and CellChek XL the thickest measurements (intraclass correlation coefficient (ICC) = 0.83; p < 0.001 and ICC = 0.78; p < 0.001, respectively). Mean endothelial cell density (ECD) given by CEM-530 was lower than CellChek XL (2613.17 ± 228.62 and 2862.72 ± 170.42 cells/mm 2 , respectively; ICC = 0.43; p < 0.001). Mean value for coefficient of variation (CV) was 28.57 ± 3.61 in CEM-530 and 30.30 ± 3.53 in CellChek XL. Cell hexagonality (HEX) with CEM-530 was higher than with CellChek XL (68.70 ± 4.16% and 45.19 ± 6.58%, respectively). ECDs with CellChek XL and CEM-530 have good correlation, but the values obtained by CellChek XL are higher than CEM-530. Measurements for HEX and CV differ significantly and show weak correlation. Thus, we do not recommend interchangeable use of CellChek XL and CEM-530. In terms of CCTs, Pentacam, CEM-530 and CellChek XL specular microscopy instruments are reliable devices.

  7. Evaluation of the Endothelial Cell Density and the Central Corneal Thickness in Pseudoexfoliation Syndrome and Pseudoexfoliation Glaucoma

    Directory of Open Access Journals (Sweden)

    Bożydar T. Tomaszewski

    2014-01-01

    Full Text Available Purpose. Evaluation of central corneal thickness (CCT and endothelial cell density (ECD in patients with senile cataract and coexisting pseudoexfoliation (PEX syndrome with glaucoma (PEXG and without glaucoma using specular microscopy. Participants and Methods. The study included 122 patients (217 eyes. In this group of patients we identified 133 eyes with PEX syndrome (65 with glaucoma, 68 without glaucoma and 84 eyes without PEX syndrome. ECD and CCT were measured in each eye by specular microscopy. Results. ECD in eyes with PEX syndrome without glaucoma (2297 ± 359 cell/mm2 and in eyes with PEXG (2241 ± 363 cell/mm2 was lower than in the control group (2503 ± 262 cell/mm2 (P<0.001. CCT in eyes with PEXG (508.2 ± 32.6 μm was thinner than in eyes with PEX syndrome without glaucoma (529.7 ± 30.3 μm and control group (527.7 ± 29.4 μm (P<0.001. Conclusions. This research shows that in eyes with PEX syndrome, both with and without glaucoma, ECD was statistically significantly lower than in the control group. In patients with PEXG, CCT was statistically significantly thinner than in the PEX syndrome and control group.

  8. Endothelial and lipoprotein lipases in human and mouse placenta

    DEFF Research Database (Denmark)

    Lindegaard, Marie L S; Olivecrona, Gunilla; Christoffersen, Christina

    2005-01-01

    Placenta expresses various lipase activities. However, a detailed characterization of the involved genes and proteins is lacking. In this study, we compared the expression of endothelial lipase (EL) and LPL in human term placenta. When placental protein extracts were separated by heparin-Sepharos...

  9. Mouse lung contains endothelial progenitors with high capacity to form blood and lymphatic vessels

    Directory of Open Access Journals (Sweden)

    Barleon Bernhard

    2010-07-01

    Full Text Available Abstract Background Postnatal endothelial progenitor cells (EPCs have been successfully isolated from whole bone marrow, blood and the walls of conduit vessels. They can, therefore, be classified into circulating and resident progenitor cells. The differentiation capacity of resident lung endothelial progenitor cells from mouse has not been evaluated. Results In an attempt to isolate differentiated mature endothelial cells from mouse lung we found that the lung contains EPCs with a high vasculogenic capacity and capability of de novo vasculogenesis for blood and lymph vessels. Mouse lung microvascular endothelial cells (MLMVECs were isolated by selection of CD31+ cells. Whereas the majority of the CD31+ cells did not divide, some scattered cells started to proliferate giving rise to large colonies (> 3000 cells/colony. These highly dividing cells possess the capacity to integrate into various types of vessels including blood and lymph vessels unveiling the existence of local microvascular endothelial progenitor cells (LMEPCs in adult mouse lung. EPCs could be amplified > passage 30 and still expressed panendothelial markers as well as the progenitor cell antigens, but not antigens for immune cells and hematopoietic stem cells. A high percentage of these cells are also positive for Lyve1, Prox1, podoplanin and VEGFR-3 indicating that a considerabe fraction of the cells are committed to develop lymphatic endothelium. Clonogenic highly proliferating cells from limiting dilution assays were also bipotent. Combined in vitro and in vivo spheroid and matrigel assays revealed that these EPCs exhibit vasculogenic capacity by forming functional blood and lymph vessels. Conclusion The lung contains large numbers of EPCs that display commitment for both types of vessels, suggesting that lung blood and lymphatic endothelial cells are derived from a single progenitor cell.

  10. Sildenafil restores endothelial function in the apolipoprotein E knockout mouse

    Directory of Open Access Journals (Sweden)

    Balarini Camille M

    2013-01-01

    Full Text Available Abstract Background Atherosclerosis is an inflammatory process of the arterial walls and is initiated by endothelial dysfunction accompanied by an imbalance in the production of reactive oxygen species (ROS and nitric oxide (NO. Sildenafil, a selective phosphodiesterase-5 (PDE5 inhibitor used for erectile dysfunction, exerts its cardiovascular effects by enhancing the effects of NO. The aim of this study was to investigate the influence of sildenafil on endothelial function and atherosclerosis progression in apolipoprotein E knockout (apoE−/− mice. Methods ApoE−/− mice treated with sildenafil (Viagra®, 40 mg/kg/day, for 3 weeks, by oral gavage were compared to the untreated apoE−/− and the wild-type (WT mice. Aortic rings were used to evaluate the relaxation responses to acetylcholine (ACh in all of the groups. In a separate set of experiments, the roles of NO and ROS in the relaxation response to ACh were evaluated by incubating the aortic rings with L-NAME (NO synthase inhibitor or apocynin (NADPH oxidase inhibitor. In addition, the atherosclerotic lesions were quantified and superoxide production was assessed. Results Sildenafil restored the vasodilator response to acetylcholine (ACh in the aortic rings of the apoE−/− mice. Treatment with L-NAME abolished the vasodilator responses to ACh in all three groups of mice and revealed an augmented participation of NO in the endothelium-dependent vasodilation in the sildenafil-treated animals. The normalized endothelial function in sildenafil-treated apoE−/− mice was unaffected by apocynin highlighting the low levels of ROS production in these animals. Moreover, morphological analysis showed that sildenafil treatment caused approximately a 40% decrease in plaque deposition in the aorta. Conclusion This is the first study demonstrating the beneficial effects of chronic treatment with sildenafil on endothelial dysfunction and atherosclerosis in a model of spontaneous

  11. Corneal endothelial cell loss and corneal biomechanical characteristics after two-step sequential or combined phaco-vitrectomy surgery for idiopathic epiretinal membrane

    DEFF Research Database (Denmark)

    Hamoudi, Hassan; Christensen, Ulrik Correll; La Cour, Morten

    2017-01-01

    with non-contact specular microscopy. Pachymetry [central cornea thickness (CCT)], keratometry and cornea volume (CV) were measured with Pentacam Scheimpflug camera. Primary outcome was change in CED after 12 months; secondary outcomes were changes in CCT and CV after 12 months. RESULTS: Sixty-two eyes......PURPOSE: To assess the impact of sequential and combined surgery [cataract surgery and 23-gauge pars plana vitrectomy (PPV) with peeling] on corneal endothelium cell density (CED) and corneal biomechanical characteristics. METHODS: Phakic eyes with epiretinal membrane (ERM) were prospectively...... allocated to (i) cataract surgery and subsequent PPV (CAT group), (ii) PPV and subsequent cataract surgery (VIT group) or (iii) phacovitrectomy (COMBI group). Eyes were examined at baseline, 1 month after each surgery, and at 3 and 12 months follow-up. Corneal endothelium cell density (CED) was assessed...

  12. TGC repeat expansion in the TCF4 gene increases the risk of Fuchs' endothelial corneal dystrophy in Australian cases.

    Directory of Open Access Journals (Sweden)

    Abraham Kuot

    Full Text Available Fuchs' endothelial corneal dystrophy (FECD is a progressive, vision impairing disease. Common single nucleotide polymorphisms (SNPs and a trinucleotide repeat polymorphism, thymine-guanine-cytosine (TGC, in the TCF4 gene have been associated with the risk of FECD in some populations. We previously reported association of SNPs in TCF4 with FECD risk in the Australian population. The aim of this study was to determine whether TGC repeat polymorphism in TCF4 is associated with FECD in the Australian population. In 189 unrelated Australian cases with advanced late-onset FECD and 183 matched controls, the TGC repeat polymorphism located in intron 3 of TCF4 was genotyped using a short tandem repeat (STR assay. The repeat length was verified by direct sequencing in selected homozygous carriers. We found significant association between the expanded TGC repeat (≥ 40 repeats in TCF4 and advanced FECD (P = 2.58 × 10-22; OR = 15.66 (95% CI: 7.79-31.49. Genotypic analysis showed that 51% of cases (97 compared to 5% of controls (9 were heterozygous or homozygous for the expanded repeat allele. Furthermore, the repeat expansion showed stronger association than the most significantly associated SNP, rs613872, in TCF4, with the disease in the Australian cohort. This and haplotype analysis of both the polymorphisms suggest that considering both the polymorphisms together rather than either of the two alone would better predict susceptibility to FECD in the Australian population. This is the first study to report association of the TGC trinucleotide repeat expansion in TCF4 with advanced FECD in the Australian population.

  13. Topical versus subconjunctival anti-vascular endothelial growth factor therapy (Bevacizumab, Ranibizumab and Aflibercept for treatment of corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Tariq Al-Debasi

    2017-04-01

    Anti-VEGF agents (Bevacizumab, Ranibizumab and Aflibercept seem to have a higher efficiency and efficacy for corneal NV treatment. Both subconjunctival therapy and topical therapy of bevacizumab prohibit corneal NV, while early treatment with subconjunctival administration of ranibizumab may successfully reduce corneal NV. Therefore, establishment of safe doses is highly important before these drugs can be involved in the clinical setting. Further investigations and studies are highly warranted to adjust the dose and route of administration for the antibodies directed against VEGF to be the key therapeutic agents in the corneal NV treatment.

  14. Visual outcome and changes in corneal endothelial cell density following aphakic iris-fixated intraocular lens implantation in pediatric eyes with subluxated lenses.

    Science.gov (United States)

    Siddiqui, Sorath Noorani; Khan, Ayesha

    2013-01-01

    To evaluate the visual outcome and corneal endothelial cell density after Artisan aphakic intraocular lens (IOL) implantation (Ophtec, Groningen, the Netherlands) in pediatric eyes with subluxated lenses. Artisan aphakic IOLs were implanted in 18 eyes of 11 children with subluxated lenses. Idiopathic subluxations and ectopia lentis due to Marfan syndrome were included, whereas subluxations due to trauma or buphthalmos were excluded. Best-corrected visual acuity (BCVA) and endothelial cell density were monitored. Mean postoperative BCVA and endothelial cell density at last follow-up visit were calculated. The age of children at the time of Artisan aphakic IOL implantation ranged from 8 to 16 years (mean: 11.58 ± 2.9 years). Mean follow-up was 9.12 ± 4.30 months. Mean postoperative logarithm of the minimum angle of resolution BCVA was 0.26 ± 0.13 (P = .001) and mean postoperative endothelial cell density was 2,860 ± 435 cells/mm(2) (P = .000). Mean endothelial cell loss was 17.1%. Artisan aphakic IOL implantation is a safe surgical choice in the management of ectopia lentis in the pediatric age group. It has minimal complications and is less traumatic to pediatric eyes. However, long-term follow-up of these children is required.[J Pediatr Ophthalmol Strabismus 2013;50(3):178-182.]. Copyright 2013, SLACK Incorporated.

  15. The Effect of a p38 Mitogen-Activated Protein Kinase Inhibitor on Cellular Senescence of Cultivated Human Corneal Endothelial Cells.

    Science.gov (United States)

    Hongo, Akane; Okumura, Naoki; Nakahara, Makiko; Kay, EunDuck P; Koizumi, Noriko

    2017-07-01

    We have begun a clinical trial of a cell-based therapy for corneal endothelial dysfunction in Japan. The purpose of this study was to investigate the usefulness of a p38 MAPK inhibitor for prevention cellular senescence in cultivated human corneal endothelial cells (HCECs). HCECs of 10 donor corneas were divided and cultured with or without SB203580 (a p38 MAPK inhibitor). Cell density and morphology were evaluated by phase-contrast microscopy. Expression of function-related proteins was examined by immunofluorescent staining. Cellular senescence was evaluated by SA-β-gal staining and Western blotting for p16 and p21. Senescence-associated factors were evaluated by membrane blotting array, quantitative PCR, and ELISA. Phase-contrast microscopy showed a significantly higher cell density for HCECs cultured with SB203580 than without SB203580 (2623 ± 657 cells/mm2 and 1752 ± 628 cells/mm2, respectively). The HCECs cultured with SB203580 maintained a hexagonal morphology and expressed ZO-1, N-cadherin, and Na+/K+-ATPase in the plasma membrane, whereas the control HCECs showed an altered staining pattern for these marker proteins. HCECs cultured without SB203580 showed high positive SA-β-gal staining, a low nuclear/cytoplasm ratio, and expression of p16 and p21. IL-6, IL-8, CCL2, and CXCL1 were observed at high levels in low cell density HCECs cultured without SB203580. Activation of p38 MAPK signaling due to culture stress might be a causative factor that induces cellular senescence; therefore, the use of p38 MAPK inhibitor to counteract senescence may achieve sufficient numbers of HCECs for tissue engineering therapy for corneal endothelial dysfunction.

  16. Optimized human platelet lysate as novel basis for a serum-, xeno-, and additive-free corneal endothelial cell and tissue culture.

    Science.gov (United States)

    Thieme, Daniel; Reuland, Lynn; Lindl, Toni; Kruse, Friedrich; Fuchsluger, Thomas

    2018-02-01

    The expansion of donor-derived corneal endothelial cells (ECs) is a promising approach for regenerative therapies in corneal diseases. To achieve the best Good Manufacturing Practice standard the entire cultivation process should be devoid of nonhuman components. However, so far, there is no suitable xeno-free protocol for clinical applications. We therefore introduce a processed variant of a platelet lysate for the use in corneal cell and tissue culture based on a Good Manufacturing Practice-grade thrombocyte concentrate. This processed human platelet lysate (phPL), free of any animal components and of anticoagulants such as heparin with a physiological ionic composition, was used to cultivate corneal ECs in vitro and ex vivo in comparison to standard cultivation with fetal calf serum (FCS). Human donor corneas were cut in quarters while 2 quarters of each cornea were incubated with the respective medium supplement. Three fields of view per quarter were taken into account for the analysis. Evaluation of phPL as a medium supplement in cell culture of immortalized EC showed a superior viability compared with FCS control with reduced cell proliferation. Furthermore, the viability during the expansion of primary cells is significantly (3-fold ±0.5) increased with phPL compared with FCS standard medium. Quartering donor corneas was traumatic for the endothelium and therefore resulted in increased EC loss. Interestingly, however, cultivation of the quartered pieces for 2 weeks in 0.1-mg/ml pHPL in Biochrome I showed a 21 (±10) % EC loss compared with 67 (±12) % EC loss when cultivated in 2% FCS in Biochrome I. The cell culture protocol with pHPL as FCS replacement seems to be superior to the standard FCS protocols with respect to EC survival. It offers a xeno-free and physiological environment for corneal endothelial cells. This alternative cultivation protocol could facilitate the use of EC for human corneal cell therapy. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Mechanisms of allograft rejection of corneal endothelium

    International Nuclear Information System (INIS)

    Tagawa, Y.; Silverstein, A.M.; Prendergast, R.A.

    1982-01-01

    The local intraocular graft-vs.-host (GVH) reaction, involving the destruction of the corneal endothelial cells of the rabbit host by sensitized donor lymphoid cells, has been used to study the mechanism of corneal allograft rejection. Pretreatment of donor cells with a specific mouse monoclonal hybridoma anti-T cell antibody and complement suppresses the destructive reaction, suggesting that a cellular-immune mechanism is primarily involved. Pretreatment of donor cells with mitomycin-C completely abolishes the local GVH reaction, indicating that the effector lymphocytes must undergo mitosis within the eye before they can engage in target cell destruction. Finally, studies of the local GVH reaction in irradiated leukopenic recipients or in preinflamed rabbit eyes suggest that host leukocytes may contribute nonspecifically to enhance the destructive process. These studies show that the local ocular GVH reaction may provide a useful model for the study of the mechanisms involved in the rejection of corneal allografts

  18. Isolation and characterization of conditionally immortalized mouse glomerular endothelial cell lines.

    Science.gov (United States)

    Rops, Angelique L; van der Vlag, Johan; Jacobs, Cor W; Dijkman, Henry B; Lensen, Joost F; Wijnhoven, Tessa J; van den Heuvel, Lambert P; van Kuppevelt, Toin H; Berden, Jo H

    2004-12-01

    The culture and establishment of glomerular cell lines has proven to be an important tool for the understanding of glomerular cell functions in glomerular physiology and pathology. Especially, the recent establishment of a conditionally immortalized visceral epithelial cell line has greatly boosted the research on podocyte biology. Glomeruli were isolated from H-2Kb-tsA58 transgenic mice that contain a gene encoding a temperature-sensitive variant of the SV40 large tumor antigen, facilitating proliferative growth at 33 degrees C and differentiation at 37 degrees C. Glomerular endothelial cells were isolated from glomerular outgrowth by magnetic beads loaded with CD31, CD105, GSL I-B4, and ULEX. Clonal cell lines were characterized by immunofluorescence staining with antibodies/lectins specific for markers of endothelial cells, podocytes, and mesangial cells. Putative glomerular endothelial cell lines were analyzed for (1) cytokine-induced expression of adhesion molecules; (2) tube formation on Matrigel coating; and (3) the presence of fenestrae. As judged by immunostaining for Wilms tumor-1, smooth muscle actin (SMA), podocalyxin, and von Willebrand factor (vWF), we obtained putative endothelial, podocyte and mesangial cell lines. The mouse glomerular endothelial cell clone #1 (mGEnC-1) was positive for vWF, podocalyxin, CD31, CD105, VE-cadherin, GSL I-B4, and ULEX, internalized acetylated-low-density lipoprotein (LDL), and showed increased expression of adhesion molecules after activation with proinflammatory cytokines. Furthermore, mGEnC-1 formed tubes and contained nondiaphragmed fenestrae. The mGEnC-1 represents a conditionally immortalized cell line with various characteristics of differentiated glomerular endothelial cells when cultured at 37 degrees C. Most important, mGEnC-1 contains nondiaphragmed fenestrae, which is a unique feature of glomerular endothelial cells.

  19. EGF suppresses hydrogen peroxide induced Ca2+ influx by inhibiting L-type channel activity in cultured human corneal endothelial cells.

    Science.gov (United States)

    Mergler, Stefan; Pleyer, Uwe; Reinach, Peter; Bednarz, Jürgen; Dannowski, Haike; Engelmann, Katrin; Hartmann, Christian; Yousif, Tarik

    2005-02-01

    Endogenous generated hydrogen peroxide during eye bank storage limits viability. We determined in cultured human corneal endothelial cells (HCEC) whether: (1) this oxidant induces elevations in intracellular calcium concentration [Ca2+]i; (2) epidermal growth factor (EGF) medium supplementation has a protective effect against peroxide mediated rises in [Ca2+]i. Whereas pathophysiological concentrations of H2O2 (10 mM) induced irreversible large increases in [Ca2+]i, lower concentrations (up to 1 mM) had smaller effects, which were further reduced by exposure to either 5 microM nifedipine or EGF (10 ng ml(-1)). EGF had a larger protective effect against H2O2-induced rises in [Ca2+]i than nifedipine. In addition, icilin, the agonist for the temperature sensitive transient receptor potential protein, TRPM8, had complex dose-dependent effects (i.e. 10 and 50 microM) on [Ca2+]i. At 10 microM, it reversibly elevated [Ca2+]i whereas at 50 microM an opposite effect occurred suggesting complex effects of temperature on endothelial viability. Taken together, H2O2 induces rises in [Ca2+]i that occur through increases in Ca2+ permeation along plasma membrane pathways that include L-type Ca2+ channels as well as other EGF-sensitive pathways. As EGF overcomes H2O2-induced rises in [Ca2+]i, its presence during eye bank storage could improve the outcome of corneal transplant surgery.

  20. Successful transplantation of in vitro expanded human cadaver corneal endothelial precursor cells on to a cadaver bovine's eye using a nanocomposite gel sheet.

    Science.gov (United States)

    Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K

    2014-05-01

    In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.

  1. Cardiac endothelial cells isolated from mouse heart - a novel model for radiobiology

    International Nuclear Information System (INIS)

    Jelonek, K.; Walaszczyk, A.; Gabrys, D.; Pietrowska, M.; Widlak, P.; Kanthou, Ch.

    2011-01-01

    Cardiovascular disease is recognized as an important clinical problem in radiotherapy and radiation protection. However, only few radiobiological models relevant for assessment of cardiotoxic effects of ionizing radiation are available. Here we describe the isolation of mouse primary cardiac endothelial cells, a possible target for cardiotoxic effects of radiation. Cells isolated from hearts of juvenile mice were cultured and irradiated in vitro. In addition, cells isolated from hearts of locally irradiated adult animals (up to 6 days after irradiation) were tested. A dose-dependent formation of histone γH 2 A.X foci was observed after in vitro irradiation of cultured cells. However, such cells were resistant to radiation-induced apoptosis. Increased levels of actin stress fibres were observed in the cytoplasm of cardiac endothelial cells irradiated in vitro or isolated from irradiated animals. A high dose of 16 Gy did not increase permeability to Dextran in monolayers formed by endothelial cells. Up-regulated expression of Vcam1, Sele and Hsp70i genes was detected after irradiation in vitro and in cells isolated few days after irradiation in vivo. The increased level of actin stress fibres and enhanced expression of stress-response genes in irradiated endothelial cells are potentially involved in cardiotoxic effects of ionizing radiation. (authors)

  2. Vps35-deficiency impairs SLC4A11 trafficking and promotes corneal dystrophy.

    Directory of Open Access Journals (Sweden)

    Wei Liu

    Full Text Available Vps35 (vacuolar protein sorting 35 is a major component of retromer that selectively promotes endosome-to-Golgi retrieval of transmembrane proteins. Dysfunction of retromer is a risk factor for the pathogenesis of Parkinson's disease (PD and Alzheimer's disease (AD. However, Vps35/retromer's function in the eye or the contribution of Vps35-deficiency to eye degenerative disorders remains to be explored. Here we provide evidence for a critical role of Vps35 in mouse corneal dystrophy. Vps35 is expressed in mouse and human cornea. Mouse cornea from Vps35 heterozygotes (Vps35+/- show features of dystrophy, such as loss of both endothelial and epithelial cell densities, disorganizations of endothelial, stroma, and epithelial cells, excrescences in the Descemet membrane, and corneal edema. Additionally, corneal epithelial cell proliferation was reduced in Vps35-deficient mice. Intriguingly, cell surface targeting of SLC4A11, a membrane transport protein (OH- /H+ /NH3 /H2O of corneal endothelium, whose mutations have been identified in patients with corneal dystrophy, was impaired in Vps35-deficient cells and cornea. Taken together, these results suggest that SLC4A11 appears to be a Vps35/retromer cargo, and Vps35-regulation of SLC4A11 trafficking may underlie Vps35/retromer regulation of corneal dystrophy.

  3. Bone marrow endothelial progenitors augment atherosclerotic plaque regression in a mouse model of plasma lipid lowering

    Science.gov (United States)

    Yao, Longbiao; Heuser-Baker, Janet; Herlea-Pana, Oana; Iida, Ryuji; Wang, Qilong; Zou, Ming-Hui; Barlic-Dicen, Jana

    2012-01-01

    The major event initiating atherosclerosis is hypercholesterolemia-induced disruption of vascular endothelium integrity. In settings of endothelial damage, endothelial progenitor cells (EPCs) are mobilized from bone marrow into circulation and home to sites of vascular injury where they aid endothelial regeneration. Given the beneficial effects of EPCs in vascular repair, we hypothesized that these cells play a pivotal role in atherosclerosis regression. We tested our hypothesis in the atherosclerosis-prone mouse model in which hypercholesterolemia, one of the main factors affecting EPC homeostasis, is reversible (Reversa mice). In these mice normalization of plasma lipids decreased atherosclerotic burden; however, plaque regression was incomplete. To explore whether endothelial progenitors contribute to atherosclerosis regression, bone marrow EPCs from a transgenic strain expressing green fluorescent protein under the control of endothelial cell-specific Tie2 promoter (Tie2-GFP+) were isolated. These cells were then adoptively transferred into atheroregressing Reversa recipients where they augmented plaque regression induced by reversal of hypercholesterolemia. Advanced plaque regression correlated with engraftment of Tie2-GFP+ EPCs into endothelium and resulted in an increase in atheroprotective nitric oxide and improved vascular relaxation. Similarly augmented plaque regression was also detected in regressing Reversa mice treated with the stem cell mobilizer AMD3100 which also mobilizes EPCs to peripheral blood. We conclude that correction of hypercholesterolemia in Reversa mice leads to partial plaque regression that can be augmented by AMD3100 treatment or by adoptive transfer of EPCs. This suggests that direct cell therapy or indirect progenitor cell mobilization therapy may be used in combination with statins to treat atherosclerosis. PMID:23081735

  4. Genomic locus modulating corneal thickness in the mouse identifies POU6F2 as a potential risk of developing glaucoma.

    Directory of Open Access Journals (Sweden)

    Rebecca King

    2018-01-01

    Full Text Available Central corneal thickness (CCT is one of the most heritable ocular traits and it is also a phenotypic risk factor for primary open angle glaucoma (POAG. The present study uses the BXD Recombinant Inbred (RI strains to identify novel quantitative trait loci (QTLs modulating CCT in the mouse with the potential of identifying a molecular link between CCT and risk of developing POAG. The BXD RI strain set was used to define mammalian genomic loci modulating CCT, with a total of 818 corneas measured from 61 BXD RI strains (between 60-100 days of age. The mice were anesthetized and the eyes were positioned in front of the lens of the Phoenix Micron IV Image-Guided OCT system or the Bioptigen OCT system. CCT data for each strain was averaged and used to QTLs modulating this phenotype using the bioinformatics tools on GeneNetwork (www.genenetwork.org. The candidate genes and genomic loci identified in the mouse were then directly compared with the summary data from a human POAG genome wide association study (NEIGHBORHOOD to determine if any genomic elements modulating mouse CCT are also risk factors for POAG.This analysis revealed one significant QTL on Chr 13 and a suggestive QTL on Chr 7. The significant locus on Chr 13 (13 to 19 Mb was examined further to define candidate genes modulating this eye phenotype. For the Chr 13 QTL in the mouse, only one gene in the region (Pou6f2 contained nonsynonymous SNPs. Of these five nonsynonymous SNPs in Pou6f2, two resulted in changes in the amino acid proline which could result in altered secondary structure affecting protein function. The 7 Mb region under the mouse Chr 13 peak distributes over 2 chromosomes in the human: Chr 1 and Chr 7. These genomic loci were examined in the NEIGHBORHOOD database to determine if they are potential risk factors for human glaucoma identified using meta-data from human GWAS. The top 50 hits all resided within one gene (POU6F2, with the highest significance level of p = 10-6 for

  5. Axenfeld-Rieger anomaly and corneal endothelial dystrophy: a case series Anomalia de Axenfeld-Rieger e distrofia corneana endotelial: uma série de casos

    Directory of Open Access Journals (Sweden)

    Mariana Borges Oliveira

    2008-12-01

    Full Text Available Report of a study of a family with a remarkable combination of endothelial corneal dystrophy, and anterior chamber dysgenesis classified as Axenfeld-Rieger anomaly. A 56 year-old female had blurred vision complaints. A slit lamp evaluation showed a bilateral posterior embryotoxon and guttata with corneal edema, Descemet membrane's folds, characterizing Fuchs endothelial dystrophy. A 27 year-old daughter was asymptomatic. The biomicroscopic exam disclosed a bilateral nasal and temporal posterior embryotoxon and a central guttata. Gonioscopy showed iridocorneal strands with a prominent Schwalbe´s line. The intraocular pressure was normal. Her sister, a 25 year-old female presented very similar abnormalities along with her brother (22 years old. A 19 year-old female sister presented the iridocorneal angle alterations, without Fuchs endothelial dystrophy, until this moment. This paper presents a family with a central cornea guttata or Fuchs dystrophy associated with Axenfeld-Rieger anomaly. Two different inherited diseases appearing together in an entire family may suggest a single molecular and genetic etiology, with high penetrance.Relato dos resultados do estudo de uma família com distrofia corneana endotelial associada a uma disgenesia do segmento anterior, a anomalia de Axenfeld-Rieger. Paciente de 56 anos, feminina, queixava-se de visão borrada. O exame na lâmpada de fenda evidenciou embriotoxo posterior bilateral e guttata no centro da córnea, edema estromal e dobras na membrana de Descemet, caracterizando distrofia endothelial de Fuchs. A filha de 27 anos estava assintomática. A biomicroscopia revelou embriotoxo posterior nasal e temporal bilateral e guttata central. A gonioscopia evidenciou processos iridocorneanos até a linha de Schwalbe, que se encontrava anteriorizada e proeminente. A pressão intra-ocular estava normal. Não foram observadas alterações sistêmicas. Sua irmã, 25 anos, sexo feminino, apresentava altera

  6. Successful transportation of human corneal endothelial tissues without cool preservation in varying Indian tropical climatic conditions and in vitro cell expansion using a novel polymer.

    Science.gov (United States)

    Rao, Srinivas K; Sudhakar, John; Parikumar, Periyasamy; Natarajan, Sundaram; Insaan, Aditya; Yoshioka, Hiroshi; Mori, Yuichi; Tsukahara, Shigeo; Baskar, Subramani; Manjunath, Sadananda Rao; Senthilkumar, Rajappa; Thamaraikannan, Paramasivam; Srinivasan, Thangavelu; Preethy, Senthilkumar; Abraham, Samuel J K

    2014-02-01

    Though the transplantation of human corneal endothelial tissue (CET) separated from cadaver cornea is in practice, its transportation has not been reported. We report the successful transportation of CET in varying Indian climatic conditions without cool preservation and the in vitro expansion of Human Corneal Endothelial Precursor Cells (HCEPCs) using a novel Thermo-reversible gelation polymer (TGP). CET from cadaver corneas (n = 67), unsuitable for transplantation, were used. In phase I, CET was transported in Basal Culture Medium (Group I) and TGP (Group II) and in Phase II, in TGP cocktail alone, from three hospitals 250-2500 km away, to a central laboratory. The transportation time ranged from 6 h to 72 h and the outdoor temperature between 20°C and 41°C. On arrival, CET were processed, cells were expanded upto 30 days in basal culture medium (Group A) and TGP scaffold (Group B). Cell viability and morphology were documented and Reverse transcription polymerase chain reaction (RT-PCR) characterization undertaken. In Phase I, TGP yielded more viable cells (0.11 × 10(6) cells) than Group I (0.04 × 10(6) cells). In Phase II, the average cell count was 5.44 × 10(4) cells. During expansion, viability of HCEPCs spheres in TGP was maintained for a longer duration. The cells from both the groups tested positive for B-3 tubulin and negative for cytokeratins K3 and K12, thereby proving them to be HCEPCs. TGP preserves the CET during transportation without cool preservation and supports in vitro expansion, with a higher yield of HCEPCs, similar to that reported in clinical studies.

  7. Successful transportation of human corneal endothelial tissues without cool preservation in varying Indian tropical climatic conditions and in vitro cell expansion using a novel polymer

    Directory of Open Access Journals (Sweden)

    Srinivas K Rao

    2014-01-01

    Full Text Available Background: Though the transplantation of human corneal endothelial tissue (CET separated from cadaver cornea is in practice, its transportation has not been reported. We report the successful transportation of CET in varying Indian climatic conditions without cool preservation and the in vitro expansion of Human Corneal Endothelial Precursor Cells (HCEPCs using a novel Thermo-reversible gelation polymer (TGP. Materials and Methods: CET from cadaver corneas (n = 67, unsuitable for transplantation, were used. In phase I, CET was transported in Basal Culture Medium (Group I and TGP (Group II and in Phase II, in TGP cocktail alone, from three hospitals 250-2500 km away, to a central laboratory. The transportation time ranged from 6 h to 72 h and the outdoor temperature between 20°C and 41°C. On arrival, CET were processed, cells were expanded upto 30 days in basal culture medium (Group A and TGP scaffold (Group B. Cell viability and morphology were documented and Reverse transcription polymerase chain reaction (RT-PCR characterization undertaken. Results: In Phase I, TGP yielded more viable cells (0.11 × 10 6 cells than Group I (0.04 × 10 6 cells. In Phase II, the average cell count was 5.44 × 10 4 cells. During expansion, viability of HCEPCs spheres in TGP was maintained for a longer duration. The cells from both the groups tested positive for B-3 tubulin and negative for cytokeratins K3 and K12, thereby proving them to be HCEPCs. Conclusion: TGP preserves the CET during transportation without cool preservation and supports in vitro expansion, with a higher yield of HCEPCs, similar to that reported in clinical studies.

  8. Corneal Laceration

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive ... Corneal Laceration Sections What Is Corneal Laceration? Corneal Laceration Symptoms What Causes ...

  9. The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas.

    Science.gov (United States)

    Hermel, Martin; Salla, Sabine; Fuest, Matthias; Walter, Peter

    2017-03-01

    Endothelial assessment is crucial in the release of corneas for grafting. We retrospectively analysed the role of endothelial morphology parameters in predicting endothelial cell loss during organ culture. Human donor corneas were cultured in minimal essential medium with 2% fetal calf serum and antibiotics. Initial endothelial morphology was assessed microscopically using score parameters polymegethism (POL), pleomorphism (PLE), granulation (GRA), vacuolization (VAC), segmentation of cell membranes (SEG), Descemet's folds (DF), trypan blue-positive cells (TBPC) and endothelial cell-free areas (ECFA). Some corneas were primarily rejected based on endothelial assessment. Endothelial cell density (ECD) was assessed at the beginning (I-ECD) and end of culture. Corneas were then placed in dehydration medium (as above + 5% dextran 500). In a subgroup, ECD was reassessed after dehydration. Endothelial cell loss during culture (ECL@Culture) and culture+dehydration (ECL-Culture&Dehydration) were calculated. Data were given as mean ± SD and analysed using multiple linear and logistic regression. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. I-ECD was 2812 ± 360/mm 2 (n = 2356). The decision to reject a cornea due to endothelial assessment was associated negatively with I-ECD (OR = 0.77/100 cells, CI 0.7-0.82) and positively with ECFA (OR = 2.7, CI 1.69-4.35), SEG (OR =1.3, CI 1.01-1.68) and donor age (OR = 1.26/decade, CI 1.33-1.41). ECL@Culture was 153 ± 201/mm 2 (n = 1277), ECL@Culture&Dehydration was 169 ± 183/mm 2 (n = 918). ECL@Culture was associated positively with donor age, I-ECD, GRA and TBPC, and negatively with PLE, and DF. ECL@Culture&Dehydration was associated positively with age, sex, initial ECD, POL, PLE, VAC and TBPC. Morphological parameters displayed associations with the exclusion of corneas from culture and with endothelial cell loss. Appropriate parameter selection for screening purposes may help improve

  10. A novel podoplanin-GFPCre mouse strain for gene deletion in lymphatic endothelial cells.

    Science.gov (United States)

    Gil, Hyea Jin; Ma, Wanshu; Oliver, Guillermo

    2018-04-01

    The lymphatic vascular system is a one-direction network of thin-walled capillaries and larger vessels covered by a continuous layer of endothelial cells responsible for maintaining fluid homeostasis. Some of the main functions of the lymphatic vasculature are to drain fluid from the extracellular spaces and return it back to the blood circulation, lipid absorption from the intestinal tract, and transport of immune cells to lymphoid organs. A number of genes controlling the development of the mammalian lymphatic vasculature have been identified in the last few years, and their functional roles started to be characterized using gene inactivation approaches in mice. Unfortunately, only few mouse Cre strains relatively specific for lymphatic endothelial cells (LECs) are currently available. In this article, we report the generation of a novel Podoplanin (Pdpn) GFPCre transgenic mouse strain using its 5' regulatory region. Pdpn encodes a transmembrane mucin-type O-glycoprotein that is expressed on the surface of embryonic and postnatal LECs, in addition to few other cell types. Our detailed characterization of this novel strain indicates that it will be a valuable additional genetic tool for the analysis of gene function in LECs. © 2018 Wiley Periodicals, Inc.

  11. Chronic hydroxychloroquine improves endothelial dysfunction and protects kidney in a mouse model of systemic lupus erythematosus.

    Science.gov (United States)

    Gómez-Guzmán, Manuel; Jiménez, Rosario; Romero, Miguel; Sánchez, Manuel; Zarzuelo, María José; Gómez-Morales, Mercedes; O'Valle, Francisco; López-Farré, Antonio José; Algieri, Francesca; Gálvez, Julio; Pérez-Vizcaino, Francisco; Sabio, José Mario; Duarte, Juan

    2014-08-01

    Hydroxychloroquine has been shown to be efficacious in the treatment of autoimmune diseases, including systemic lupus erythematosus. Hydroxychloroquine-treated lupus patients showed a lower incidence of thromboembolic disease. Endothelial dysfunction, the earliest indicator of the development of cardiovascular disease, is present in lupus. Whether hydroxychloroquine improves endothelial function in lupus is not clear. The aim of this study was to analyze the effects of hydroxychloroquine on hypertension, endothelial dysfunction, and renal injury in a female mouse model of lupus. NZBWF1 (lupus) and NZW/LacJ (control) mice were treated with hydroxychloroquine 10 mg/kg per day by oral gavage, or with tempol and apocynin in the drinking water, for 5 weeks. Hydroxychloroquine treatment did not alter lupus disease activity (assessed by plasma double-stranded DNA autoantibodies) but prevented hypertension, cardiac and renal hypertrophy, proteinuria, and renal injury in lupus mice. Aortae from lupus mice showed reduced endothelium-dependent vasodilator responses to acetylcholine and enhanced contraction to phenylephrine, which were normalized by hydroxychloroquine or antioxidant treatments. No differences among all experimental groups were found in both the relaxant responses to acetylcholine and the contractile responses to phenylephrine in rings incubated with the nitric oxide synthase inhibitor N(G)-nitro-l-arginine methyl ester. Vascular reactive oxygen species content and mRNA levels of nicotinamide adenine dinucleotide phosphate oxidase subunits NOX-1 and p47(phox) were increased in lupus mice and reduced by hydroxychloroquine or antioxidants. Chronic hydroxychloroquine treatment reduced hypertension, endothelial dysfunction, and organ damage in severe lupus mice, despite the persistent elevation of anti-double-stranded DNA, suggesting the involvement of new additional mechanisms to improve cardiovascular complications. © 2014 American Heart Association, Inc.

  12. Endothelial ATP-binding cassette G1 in mouse endothelium protects against hemodynamic-induced atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Shanshan [Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070 (China); Department of Pediatrics, Baodi District People’s Hospital of Tianjin City, Tianjin, 301800 (China); Wang, Jiaxing [Department of Physiology and Pathophysiology, Peking University Health Science Center, Beijing, 100191 (China); Zhang, Xu; Shi, Ying; Li, Bochuan; Bao, Qiankun [Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070 (China); Pang, Wei [Department of Physiology and Pathophysiology, Peking University Health Science Center, Beijing, 100191 (China); Ai, Ding [Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070 (China); Zhu, Yi [Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070 (China); Department of Physiology and Pathophysiology, Peking University Health Science Center, Beijing, 100191 (China); He, Jinlong, E-mail: hejinlong@tmu.edu.cn [Department of Physiology and Pathophysiology, Tianjin Medical University, Tianjin, 300070 (China)

    2016-08-19

    Activated vascular endothelium inflammation under persistent hyperlipidemia is the initial step of atherogenesis. ATP-binding cassette G1 (ABCG1) is a crucial factor maintaining sterol and lipid homeostasis by transporting cholesterol efflux to high-density lipoprotein. In this study, we investigated the protective effects of ABCG1 in endothelial inflammation activation during early-stage atherogenesis in mice and the underlying mechanisms. Endothelial cell (EC)-specific ABCG1 transgenic (EC-ABCG1-Tg) mice were generated and cross-bred with low-density lipoprotein receptor–deficient (Ldlr{sup −/−}) mice. After a 4-week Western-type diet, the mice were sacrificed for assessing atherosclerosis. Human umbilical vein ECs were treated with different flows, and ABCG1 was adenovirally overexpressed to investigate the mechanism in vitro. Compared with Ldlr{sup −/−} mouse aortas, EC-ABCG1-Tg/Ldlr{sup −/−} aortas showed decreased early-stage lesions. Furthermore, the lesion area in the EC-ABCG1-Tg/Ldlr{sup −/−} mouse aortic arch but not thoracic aorta was significantly reduced, which suggests a protective role of ABCG1 under atheroprone flow. In vitro, overexpression of ABCG1 attenuated EC activation caused by oscillatory shear stress. Overexpression of ABCG1 blunted cholesterol-activated ECs in vitro. In exploring the mechanisms of ABCG1 attenuating endothelial inflammation, we found that ABCG1 inhibited oscillatory flow-activated nuclear factor kappa B and NLRP3 inflammasome in ECs. ABCG1 may play a protective role in early-stage atherosclerosis by reducing endothelial activation induced by oscillatory shear stress via suppressing the inflammatory response. - Highlights: • EC-ABCG1-Tg mice in a Ldlr{sup −/−} background showed decreased atherosclerosis. • Overexpression of ABCG1 in ECs decreased OSS-induced EC activation. • NLRP3 and NF-κB might be an underlying mechanism of ABCG1 protective role.

  13. Ectopic expression of the calcium-binding protein parvalbumin in mouse liver endothelial cells

    DEFF Research Database (Denmark)

    Castillo, M B; Berchtold, M W; Rülicke, T

    1997-01-01

    To elucidate the physiological role of the Ca2+ binding protein parvalbumin, we have generated transgenic mice carrying the full-length complementary DNA (cDNA) of rat parvalbumin under the control of the heavy-metal inducible metallothionein IIA promoter. Immunohistochemical and biochemical...... methods have been used to detect the presence of ectopic parvalbumin expression in different tissues. Here we show the expression of parvalbumin in endothelial cells lining the liver sinusoids in situ and after isolation in vitro. The hemodynamic effects of endothelin 1, a peptide hormone mediating potent...... vasoconstriction via calcium signalling, were investigated in the mouse liver perfused in situ. Vasoconstriction, thought to be mediated by the Ito cell, was not affected in the transgenic animals, whereas microvascular exchange, probed with the multiple indicator dilution technique, was markedly decreased...

  14. Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Wong Melissa HY

    2012-08-01

    Full Text Available Abstract Background The CorneaL GrAft Thickness Evaluation (COLGATE system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers. Methods This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement. Results There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962. Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963 and 0.967 (95% CI 0.942 to 0.981 for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969. The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949 and 0.968 (95% CI 0.945 to 0.982 for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003. The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts. Conclusion The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.

  15. Association of a Chromosomal Rearrangement Event with Mouse Posterior Polymorphous Corneal Dystrophy and Alterations in Csrp2bp, Dzank1, and Ovol2 Gene Expression.

    Directory of Open Access Journals (Sweden)

    Anna L Shen

    Full Text Available We have previously described a mouse model of human posterior polymorphous corneal dystrophy (PPCD and localized the causative mutation to a 6.2 Mbp region of chromosome 2, termed Ppcd1. We now show that the gene rearrangement linked to mouse Ppcd1 is a 3.9 Mbp chromosomal inversion flanked by 81 Kbp and 542 bp deletions. This recombination event leads to deletion of Csrp2bp Exons 8 through 11, Dzank1 Exons 20 and 21, and the pseudogene Znf133. In addition, we identified translocation of novel downstream sequences to positions adjacent to Csrp2bp Exon 7 and Dzank1 Exon 20. Twelve novel fusion transcripts involving Csrp2bp or Dzank1 linked to downstream sequences have been identified. Eight are expressed at detectable levels in PPCD1 but not wildtype eyes. Upregulation of two Csrp2bp fusion transcripts, as well as upregulation of the adjacent gene, Ovol2, was observed. Absence of the PPCD1 phenotype in animals haploinsufficient for Csrp2bp or both Csrp2bp and Dzank1 rules out haploinsufficiency of these genes as a cause of mouse PPCD1. Complementation experiments confirm that PPCD1 embryonic lethality is due to disruption of Csrp2bp expression. The ocular expression pattern of Csrp2bp is consistent with a role for this protein in corneal development and pathogenesis of PPCD1.

  16. Effect of surface charge of immortalized mouse cerebral endothelial cell monolayer on transport of charged solutes.

    Science.gov (United States)

    Yuan, Wei; Li, Guanglei; Gil, Eun Seok; Lowe, Tao Lu; Fu, Bingmei M

    2010-04-01

    Charge carried by the surface glycocalyx layer (SGL) of the cerebral endothelium has been shown to significantly modulate the permeability of the blood-brain barrier (BBB) to charged solutes in vivo. The cultured monolayer of bEnd3, an immortalized mouse cerebral endothelial cell line, is becoming a popular in vitro BBB model due to its easy growth and maintenance of many BBB characteristics over repeated passages. To test whether the SGL of bEnd3 monolayer carries similar charge as that in the intact BBB and quantify this charge, which can be characterized by the SGL thickness (L(f)) and charge density (C(mf)), we measured the solute permeability of bEnd3 monolayer to neutral solutes and to solutes with similar size but opposite charges: negatively charged alpha-lactalbumin (-11) and positively charged ribonuclease (+3). Combining the measured permeability data with a transport model across the cell monolayer, we predicted the L(f) and the C(mf) of bEnd3 monolayer, which is approximately 160 nm and approximately 25 mEq/L, respectively. We also investigated whether orosomucoid, a plasma glycoprotein modulating the charge of the intact BBB, alters the charge of bEnd3 monolayer. We found that 1 mg/mL orosomucoid would increase SGL charge density of bEnd3 monolayer to approximately 2-fold of its control value.

  17. Vascular endothelial growth factors enhance the permeability of the mouse blood-brain barrier.

    Directory of Open Access Journals (Sweden)

    Shize Jiang

    Full Text Available The blood-brain barrier (BBB impedes entry of many drugs into the brain, limiting clinical efficacy. A safe and efficient method for reversibly increasing BBB permeability would greatly facilitate central nervous system (CNS drug delivery and expand the range of possible therapeutics to include water soluble compounds, proteins, nucleotides, and other large molecules. We examined the effect of vascular endothelial growth factor (VEGF on BBB permeability in Kunming (KM mice. Human VEGF165 was administered to treatment groups at two concentrations (1.6 or 3.0 µg/mouse, while controls received equal-volume saline. Changes in BBB permeability were measured by parenchymal accumulation of the contrast agent Gd-DTPA as assessed by 7 T magnetic resonance imaging (MRI. Mice were then injected with Evans blue, sacrificed 0.5 h later, and perfused transcardially. Brains were removed, fixed, and sectioned for histological study. Both VEGF groups exhibited a significantly greater signal intensity from the cerebral cortex and basal ganglia than controls (P<0.001. Evans blue fluorescence intensity was higher in the parenchyma and lower in the cerebrovasculature of VEGF-treated animals compared to controls. No significant brain edema was observed by diffusion weighted MRI (DWI or histological staining. Exogenous application of VEGF can increase the permeability of the BBB without causing brain edema. Pretreatment with VEGF may be a feasible method to facilitate drug delivery into the CNS.

  18. AFM-based detection of glycocalyx degradation and endothelial stiffening in the db/db mouse model of diabetes.

    Science.gov (United States)

    Targosz-Korecka, Marta; Jaglarz, Magdalena; Malek-Zietek, Katarzyna E; Gregorius, Aleksandra; Zakrzewska, Agnieszka; Sitek, Barbara; Rajfur, Zenon; Chlopicki, Stefan; Szymonski, Marek

    2017-11-21

    Degradation of the glycocalyx and stiffening of endothelium are important pathophysiological components of endothelial dysfunction. However, to our knowledge, these events have not been investigated in tandem in experimental diabetes. Here, the mechanical properties of the glycocalyx and endothelium in ex vivo mouse aorta were determined simultaneously in indentation experiments with an atomic force microscope (AFM) for diabetic db/db and control db/+ mice at ages of 11-19 weeks. To analyze highly heterogeneous aorta samples, we developed a tailored classification procedure of indentation data based on a bi-layer brush model supplemented with Hertz model for quantification of nanomechanics of endothelial regions with and without the glycocalyx surface. In db/db mice, marked endothelial stiffening and reduced glycocalyx coverage were present already in 11-week-old mice and persisted in older animals. In contrast, reduction of the effective glycocalyx length was progressive and was most pronounced in 19-week-old db/db mice. The reduction of the glycocalyx length correlated with an increasing level of glycated haemoglobin and decreased endothelial NO production. In conclusion, AFM nanoindentation analysis revealed that stiffening of endothelial cells and diminished glycocalyx coverage occurred in early diabetes and were followed by the reduction of the glycocalyx length that correlated with diabetes progression.

  19. Posttranslational inactivation of endothelial nitric oxide synthase in the transgenic sickle cell mouse penis

    Science.gov (United States)

    Musicki, Biljana; Champion, Hunter C.; Hsu, Lewis L.; Bivalacqua, Trinity J.; Burnett, Arthur L.

    2017-01-01

    INTRODUCTION Sickle cell disease (SCD)-associated priapism is characterized by endothelial nitric oxide synthase (eNOS) dysfunction in the penis. However, the mechanism of decreased eNOS function/activation in the penis in association with SCD is not known. AIMS Our hypothesis in the present study was that eNOS is functionally inactivated in the SCD penis in association with impairments in eNOS posttranslational phosphorylation and the enzyme’s interactions with its regulatory proteins. METHODS Sickle cell transgenic (sickle) mice were used as an animal model of SCD. Wild type (WT) mice served as controls. Penes were excised at baseline for molecular studies. eNOS phosphorylation on Ser-1177 (positive regulatory site) and Thr-495 (negative regulatory site), total eNOS, and phosphorylated AKT (upstream mediator of eNOS phosphorylation on Ser-1177) expressions, and eNOS interactions with heat shock protein 90 (HSP90) and caveolin-1 were measured by Western blot. Constitutive NOS catalytic activity was measured by conversion of L-[14C]arginine-to-L-[14C]citrulline in the presence of calcium. MAIN OUTCOME MEASURES Molecular mechanisms of eNOS dysfunction in the sickle mouse penis. RESULTS eNOS phosphorylated on Ser-1177, an active portion of eNOS, was decreased in the sickle mouse penis compared to WT penis. eNOS interaction with its positive protein regulator HSP90, but not with its negative protein regulator caveolin-1, and phosphorylated AKT expression, as well as constitutive NOS activity, were also decreased in the sickle mouse penis compared to WT penis. eNOS phosphorylated on Thr-495, total eNOS, HSP90, and caveolin-1 protein expressions in the penis were not affected by SCD. CONCLUSION These findings provide a molecular basis for chronically reduced eNOS function in the penis by SCD, which involves decreased eNOS phosphorylation on Ser-1177 and decreased eNOS-HSP90 interaction. PMID:21143412

  20. Corneal Laceration

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Causes Corneal Laceration? Corneal Laceration Diagnosis Corneal Laceration Treatment What Is Corneal Laceration? Leer en Español: ¿Qué ...

  1. Effects of the PPARγ agonist troglitazone on endothelial cells in vivo and in vitro: Differences between human and mouse

    International Nuclear Information System (INIS)

    Kakiuchi-Kiyota, Satoko; Vetro, Joseph A.; Suzuki, Shugo; Varney, Michelle L.; Han, Huai-Yun; Nascimento, Merielen; Pennington, Karen L.; Arnold, Lora L.; Singh, Rakesh K.; Cohen, Samuel M.

    2009-01-01

    Peroxisome proliferator-activated receptor gamma (PPARγ) agonists and PPARγ/α dual agonists have been or are being developed for clinical use in the treatment of type 2 diabetes mellitus and hyperlipidemias. A common tumor finding in rodent carcinogenicity studies for these agonists is hemangioma/hemangiosarcoma in mice but not in rats. We hypothesized that increased endothelial cell proliferation may be involved in the mechanism of PPAR agonist-induced vascular tumors in mice, and we investigated the effects on endothelial cells utilizing troglitazone, the first clinically used PPARγ agonist, in vivo and in vitro. Troglitazone (400 and 800 mg/kg/day) induced hemangiosarcomas in mice in a 2-year bioassay. We showed that troglitazone increased endothelial cell proliferation in brown and white adipose tissue and liver in mice at sarcomagenic doses after 4 weeks of treatment. Troglitazone was cytotoxic both to human dermal microvascular endothelial cells (HMEC1) and mouse mammary fat pad microvascular endothelial cells (MFP MVEC) at high concentrations. However, MFP MVEC were more resistant to the cytotoxic effects of troglitazone based on the much lower LC 50 in HMEC1 (17.4 μM) compared to MFP MVEC (92.2 μM). Troglitazone increased the proliferation and survival of MFP MVEC but not HMEC1 in growth factor reduced conditions. Our data demonstrate that troglitazone may induce hemangiosarcomas in mice, at least in part, through enhancement of survival and proliferation of microvascular endothelial cells. Such an effect does not occur with human cells, suggesting that human may react differently to exposure to PPAR agonists compared with mice.

  2. Limitations of the colloidal silica method in mapping the endothelial plasma membrane proteome of the mouse heart.

    Science.gov (United States)

    Arjunan, Selvam; Reinartz, Michael; Emde, Barbara; Zanger, Klaus; Schrader, Jürgen

    2009-01-01

    The endothelial cell (EC) membrane is an important interface, which plays a crucial role in signal transduction. Our aim was to selectively purify luminal EC membrane proteins from the coronary vasculature of the isolated perfused mouse heart and analyze its composition with mass spectrometry (MS). To specifically label coronary ECs in the intact heart, the colloidal silica method was applied, which is based on the binding of positively charged colloidal silica to the surface of EC membranes. Transmission electron microscopy revealed the specific labeling of ECs of macro and microvessels. Two different methods of tissue homogenization (Teflon pestle and ultra blade) together with density centrifugation were used for membrane protein enrichment. Enrichment and purity was controlled by Western blot analysis using the EC-specific protein caveolin 1 and various intracellular marker proteins. The ultra blade method resulted in a tenfold enrichment of caveolin 1, while there was negligible contamination as judged by Western blot. However, protein yield was low and required pooling of ten hearts for MS. When enriched endothelial membrane proteins were digested with trypsin and analyzed by LC-MS, a total of 56 proteins could be identified, of which only 12 were membrane proteins. We conclude that coronary endothelial membranes can be conveniently labeled with colloidal silica. However, due to the ionic nature of interaction of colloidal silica with the EC membrane the shear rate required for cardiac homogenization resulted in a substantial loss of specificity.

  3. Protein tyrosine phosphatase-1B (PTP1B) helps regulate EGF-induced stimulation of S-phase entry in human corneal endothelial cells

    Science.gov (United States)

    Ishino, Yutaka; Zhu, Cheng; Harris, Deshea L.

    2008-01-01

    Purpose Human corneal endothelial cells (HCEC), particularly from older donors, only proliferate weakly in response to EGF. The protein tyrosine phosphatase, PTP1B, is known to negatively regulate EGF-induced signaling in several cell types by dephosphorylating the epidermal growth factor receptor (EGFR). The current studies were conducted to determine whether PTP1B plays a role in regulating cell cycle entry in HCEC in response to EGF stimulation. Methods Donor corneas were obtained from the National Disease Research Interchange and accepted for study based on established exclusion criteria. PTP1B was localized in the endothelium of ex vivo corneas and in cultured cells by immunocytochemistry. Western blot analysis verified PTP1B protein expression in HCEC and then compared the relative expression of EGFR and PTP1B in HCEC from young (60 years old). The effect of inhibiting the activity of PTP1B on S-phase entry was tested by comparing time-dependent BrdU incorporation in subconfluent HCEC incubated in the presence or absence of the PTP1B inhibitor, CinnGEL 2Me, before EGF stimulation. Results PTP1B was localized in a punctate pattern mainly within the cytoplasm of HCEC in ex vivo corneas and cultured cells. Western blots revealed the presence of three PTP1B-positive bands in HCEC and the control. Further western blot analysis showed no significant age-related difference in expression of EGFR (p=0.444>0.05); however, PTP1B expression was significantly higher in HCEC from older donors (p=0.024<0.05). Pre-incubation of HCEC with the PTP1B inhibitor significantly increased (p=0.019<0.05) the number of BrdU positive cells by 48 h after EGF stimulation. Conclusions Both immunolocalization and western blot studies confirmed that PTP1B is expressed in HCEC. Staining patterns strongly suggest that at least a subset of PTP1B is localized to the cytoplasm and most likely to the endoplasmic reticulum, the known site of EGFR/PTP1B interaction following EGF stimulation. PTP1B

  4. Late gestational hypoxia and a postnatal high salt diet programs endothelial dysfunction and arterial stiffness in adult mouse offspring.

    Science.gov (United States)

    Walton, Sarah L; Singh, Reetu R; Tan, Tiffany; Paravicini, Tamara M; Moritz, Karen M

    2016-03-01

    Gestational hypoxia and high dietary salt intake have both been associated with impaired vascular function in adulthood. Using a mouse model of prenatal hypoxia, we examined whether a chronic high salt diet had an additive effect in promoting vascular dysfunction in offspring. Pregnant CD1 dams were placed in a hypoxic chamber (12% O2) or housed under normal conditions (21% O2) from embryonic day 14.5 until birth. Gestational hypoxia resulted in a reduced body weight for both male and female offspring at birth. This restriction in body weight persisted until weaning, after which the animals underwent catch-up growth. At 10 weeks of age, a subset of offspring was placed on a high salt diet (5% NaCl). Pressurized myography of mesenteric resistance arteries at 12 months of age showed that both male and female offspring exposed to maternal hypoxia had significantly impaired endothelial function, as demonstrated by impaired vasodilatation to ACh but not sodium nitroprusside. Endothelial dysfunction caused by prenatal hypoxia was not exacerbated by postnatal consumption of a high salt diet. Prenatal hypoxia increased microvascular stiffness in male offspring. The combination of prenatal hypoxia and a postnatal high salt diet caused a leftward shift in the stress-strain relationship in both sexes. Histopathological analysis of aortic sections revealed a loss of elastin integrity and increased collagen, consistent with increased vascular stiffness. These results demonstrate that prenatal hypoxia programs endothelial dysfunction in both sexes. A chronic high salt diet in postnatal life had an additive deleterious effect on vascular mechanics and structural characteristics in both sexes. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  5. Curcumin induces therapeutic angiogenesis in a diabetic mouse hindlimb ischemia model via modulating the function of endothelial progenitor cells.

    Science.gov (United States)

    You, Jinzhi; Sun, Jiacheng; Ma, Teng; Yang, Ziying; Wang, Xu; Zhang, Zhiwei; Li, Jingjing; Wang, Longgang; Ii, Masaaki; Yang, Junjie; Shen, Zhenya

    2017-08-03

    Neovascularization is impaired in diabetes mellitus, which leads to the development of peripheral arterial disease and is mainly attributed to the dysfunction of endothelial progenitor cells (EPCs). Previous studies proved the promotional effect of curcumin on neovascularization in wound healing of diabetes. Thus, we hypothesize that curcumin could promote neovascularization at sites of hindlimb ischemia in diabetes and might take effect via modulating the function of EPCs. Streptozotocin-induced type 1 diabetic mice and nondiabetic mice both received unilateral hindlimb ischemic surgery. Curcumin was then administrated to the mice by lavage for 14 days consecutively. Laser Doppler perfusion imaging was conducted to demonstrate the blood flow reperfusion. Capillary density was measured in the ischemic gastrocnemius muscle. In addition, angiogenesis, migration, proliferation abilities, and senescence were determined in EPCs isolated from diabetic and nondiabetic mice. Quantitative PCR was then used to determine the mRNA expression of vascular endothelial growth factor (VEGF) and angiopoetin-1 (Ang-1) in EPCs. Curcumin application to type 1 diabetic mice significantly improved blood reperfusion and increased the capillary density in ischemic hindlimbs. The in-vitro study also revealed that the angiogenesis, migration, and proliferation abilities of EPCs and the number of senescent EPCs were reversed by curcumin application. Quantitative PCR confirmed the overexpression of VEGF-A and Ang-1 in EPCs after curcumin treatment. Curcumin could enhance neovascularization via promoting the function of EPCs in a diabetic mouse hindlimb ischemia model.

  6. Proliferation studies of the endothelial and smooth muscle cells of the mouse mesentery after irradiation

    International Nuclear Information System (INIS)

    Hirst, D.G.; Denekamp, J.; Hobson, B.

    1980-01-01

    A continuous tritium labelling technique was employed to study the effects of external β-radiation on the proliferation of endothelial cells and smooth muscle cells in the mesenteric arterioles of mice. Calculations showed very long turnover times for the two cell populations in control animals (> 2 years for endothelium and > 3 years for smooth muscle). After single doses of 20 and 45 Gy, no significant increase in endothelial proliferation was seen except at 3 weeks. No significant increase in labelling was observed in smooth muscle up to 48 weeks after irradiation. These labelling data have been compared with the pattern of cell depletion of the irradiated endothelium. It was concluded that the depletion was much earlier than expected for a slowly proliferating tissue, if all the cells were cycling very slowly. Such an early depletion is, however, consistent with cell death resulting from a small proportion of the cells having a short cell cycle. The recovery of the endothelial cell numbers between 9 and 12 months was not accompanied by a rise in the fraction of labelled cells. It is suggested that repopulation may occur from outside the treated area. (author)

  7. Corneal Laceration

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Corneal Laceration ... Laceration Treatment What Is Corneal Laceration? Leer en Español: ¿Qué es una laceración de la córnea? Written ...

  8. Corneal Transplantation

    DEFF Research Database (Denmark)

    Hjortdal, Jesper Østergaard

    with less risk of rejection episodes. Besides covering updated chapters on penetrating keratoplasty, and anterior and posterior lamellar procedures, this textbook also gives a thorough overview of the history of corneal transplantation and a detailed presentation of the microstructural components...... and to assist fellows and corneal surgeons in their advice and selection of patients for the best surgical procedure considering benefi ts and risks....

  9. Progress in corneal wound healing

    Science.gov (United States)

    Ljubimov, Alexander V.; Saghizadeh, Mehrnoosh

    2015-01-01

    Corneal wound healing is a complex process involving cell death, migration, proliferation, differentiation, and extracellular matrix remodeling. Many similarities are observed in the healing processes of corneal epithelial, stromal and endothelial cells, as well as cell-specific differences. Corneal epithelial healing largely depends on limbal stem cells and remodeling of the basement membrane. During stromal healing, keratocytes get transformed to motile and contractile myofibroblasts largely due to activation of transforming growth factor-β system. Endothelial cells heal mostly by migration and spreading, with cell proliferation playing a secondary role. In the last decade, many aspects of wound healing process in different parts of the cornea have been elucidated, and some new therapeutic approaches have emerged. The concept of limbal stem cells received rigorous experimental corroboration, with new markers uncovered and new treatment options including gene and microRNA therapy tested in experimental systems. Transplantation of limbal stem cell-enriched cultures for efficient re-epithelialization in stem cell deficiency and corneal injuries has become reality in clinical setting. Mediators and course of events during stromal healing have been detailed, and new treatment regimens including gene (decorin) and stem cell therapy for excessive healing have been designed. This is a very important advance given the popularity of various refractive surgeries entailing stromal wound healing. Successful surgical ways of replacing the diseased endothelium have been clinically tested, and new approaches to accelerate endothelial healing and suppress endothelial-mesenchymal transformation have been proposed including Rho kinase (ROCK) inhibitor eye drops and gene therapy to activate TGF-β inhibitor SMAD7. Promising new technologies with potential for corneal wound healing manipulation including microRNA, induced pluripotent stem cells to generate corneal epithelium, and

  10. Expression of the growth factor progranulin in endothelial cells influences growth and development of blood vessels: a novel mouse model.

    Science.gov (United States)

    Toh, Huishi; Cao, Mingju; Daniels, Eugene; Bateman, Andrew

    2013-01-01

    Progranulin is a secreted glycoprotein that regulates cell proliferation, migration and survival. It has roles in development, tumorigenesis, wound healing, neurodegeneration and inflammation. Endothelia in tumors, wounds and placenta express elevated levels of progranulin. In culture, progranulin activates endothelial proliferation and migration. This suggested that progranulin might regulate angiogenesis. It was, however, unclear how elevated endothelial progranulin levels influence vascular growth in vivo. To address this issue, we generated mice with progranulin expression targeted specifically to developing endothelial cells using a Tie2-promoter/enhancer construct. Three Tie2-Grn mouse lines were generated with varying Tie2-Grn copy number, and were called GrnLo, GrnMid, and GrnHi. All three lines showed increased mortality that correlates with Tie2-Grn copy number, with greatest mortality and lowest germline transmission in the GrnHi line. Death of the transgenic animals occurred around birth, and continued for three days after birth. Those that survived beyond day 3 survived into adulthood. Transgenic neonates that died showed vascular abnormalities of varying severity. Some exhibited bleeding into body cavities such as the pericardial space. Smaller localized hemorrhages were seen in many organs. Blood vessels were often dilated and thin-walled. To establish the development of these abnormalities, we examined mice at early (E10.5-14.5) and later (E15.5-17.5) developmental phases. Early events during vasculogenesis appear unaffected by Tie2-Grn as apparently normal primary vasculature had been established at E10.5. The earliest onset of vascular abnormality was at E15.5, with focal cerebral hemorrhage and enlarged vessels in various organs. Aberrant Tie2-Grn positive vessels showed thinning of the basement membrane and reduced investiture with mural cells. We conclude that progranulin promotes exaggerated vessel growth in vivo, with subsequent effects in

  11. Expression of the growth factor progranulin in endothelial cells influences growth and development of blood vessels: a novel mouse model.

    Directory of Open Access Journals (Sweden)

    Huishi Toh

    Full Text Available Progranulin is a secreted glycoprotein that regulates cell proliferation, migration and survival. It has roles in development, tumorigenesis, wound healing, neurodegeneration and inflammation. Endothelia in tumors, wounds and placenta express elevated levels of progranulin. In culture, progranulin activates endothelial proliferation and migration. This suggested that progranulin might regulate angiogenesis. It was, however, unclear how elevated endothelial progranulin levels influence vascular growth in vivo. To address this issue, we generated mice with progranulin expression targeted specifically to developing endothelial cells using a Tie2-promoter/enhancer construct. Three Tie2-Grn mouse lines were generated with varying Tie2-Grn copy number, and were called GrnLo, GrnMid, and GrnHi. All three lines showed increased mortality that correlates with Tie2-Grn copy number, with greatest mortality and lowest germline transmission in the GrnHi line. Death of the transgenic animals occurred around birth, and continued for three days after birth. Those that survived beyond day 3 survived into adulthood. Transgenic neonates that died showed vascular abnormalities of varying severity. Some exhibited bleeding into body cavities such as the pericardial space. Smaller localized hemorrhages were seen in many organs. Blood vessels were often dilated and thin-walled. To establish the development of these abnormalities, we examined mice at early (E10.5-14.5 and later (E15.5-17.5 developmental phases. Early events during vasculogenesis appear unaffected by Tie2-Grn as apparently normal primary vasculature had been established at E10.5. The earliest onset of vascular abnormality was at E15.5, with focal cerebral hemorrhage and enlarged vessels in various organs. Aberrant Tie2-Grn positive vessels showed thinning of the basement membrane and reduced investiture with mural cells. We conclude that progranulin promotes exaggerated vessel growth in vivo, with

  12. Clinical applications of corneal confocal microscopy

    Directory of Open Access Journals (Sweden)

    Mitra Tavakoli

    2008-06-01

    Full Text Available Mitra Tavakoli1, Parwez Hossain2, Rayaz A Malik11Division of Cardiovascular Medicine, University of Manchester and Manchester Royal Infirmary, Manchester, UK; 2University of Southampton, Southampton Eye Unit, Southampton General Hospital, Southampton, UKAbstract: Corneal confocal microscopy is a novel clinical technique for the study of corneal cellular structure. It provides images which are comparable to in-vitro histochemical techniques delineating corneal epithelium, Bowman’s layer, stroma, Descemet’s membrane and the corneal endothelium. Because, corneal confocal microscopy is a non invasive technique for in vivo imaging of the living cornea it has huge clinical potential to investigate numerous corneal diseases. Thus far it has been used in the detection and management of pathologic and infectious conditions, corneal dystrophies and ecstasies, monitoring contact lens induced corneal changes and for pre and post surgical evaluation (PRK, LASIK and LASEK, flap evaluations and Radial Keratotomy, and penetrating keratoplasty. Most recently it has been used as a surrogate for peripheral nerve damage in a variety of peripheral neuropathies and may have potential in acting as a surrogate marker for endothelial abnormalities.Keywords: corneal confocal microscopy, cornea, infective keratitis, corneal dystrophy, neuropathy

  13. Therapeutic effects of zerumbone in an alkali-burned corneal wound healing model.

    Science.gov (United States)

    Kim, Jong Won; Jeong, Hyuneui; Yang, Myeon-Sik; Lim, Chae Woong; Kim, Bumseok

    2017-07-01

    Cornea is an avascular transparent tissue. Ocular trauma caused by a corneal alkali burn induces corneal neovascularization (CNV), inflammation, and fibrosis, leading to vision loss. The purpose of this study was to examine the effects of Zerumbone (ZER) on corneal wound healing caused by alkali burns in mice. CNV was induced by alkali-burn injury in BALB/C female mice. Topical ZER (three times per day, 3μl each time, at concentrations of 5, 15, and 30μM) was applied to treat alkali-burned mouse corneas for 14 consecutive days. Histopathologically, ZER treatment suppressed alkali burn-induced CNV and decreased corneal epithelial defects induced by alkali burns. Corneal tissue treated with ZER showed reduced mRNA levels of pro-angiogenic genes, including vascular endothelial growth factor, matrix metalloproteinase-2 and 9, and pro-fibrotic factors such as alpha smooth muscle actin and transforming growth factor-1 and 2. Immunohistochemical analysis demonstrated that the infiltration of F4/80 and/or CCR2 positive cells was significantly decreased in ZER-treated corneas. ZER markedly inhibited the mRNA and protein levels of monocyte chemoattractant protein-1 (MCP-1) in human corneal fibroblasts and murine peritoneal macrophages. Immunoblot analysis revealed that ZER decreased the activation of signal transducer and activator of transcription 3 (STAT3), with consequent reduction of MCP-1 production by these cells. In conclusion, topical administration of ZER accelerated corneal wound healing by inhibition of STAT3 and MCP-1 production. Copyright © 2017. Published by Elsevier B.V.

  14. Corneal Laceration

    Medline Plus

    Full Text Available ... by something sharp flying into the eye. It can also be caused by something striking the eye ... If the corneal laceration is deep enough it can cause a full thickness laceration. This is when ...

  15. Corneal Laceration

    Medline Plus

    Full Text Available ... to Full Corneal Transplantation Nov 29, 2016 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry ...

  16. LPS, but not Angiotensin ll, lnduces Direct Pro-lnflammatory Effects in Cultured Mouse Arteries and Human Endothelial and Vascular Smooth Muscle Cells

    DEFF Research Database (Denmark)

    Outzen, Emilie M; Zaki, Marina; Mehryar, Rahila

    2017-01-01

    resistance-sized arteries (MRA) supported by experiments in cultured human primary endothelial and vascular smooth muscle cells. Results showed that 24-hr organ culture of mouse MRA with 10 nM Ang II had, unlike 100 ng/mL LPS, no effects on IL-6 or MCP-1 secretion, VCAM1 mRNA expression or endothelial......]-Ang II had no concentration- or time-dependent effects on IL-6 and MCP-1 secretion in human umbilical vein endothelial cells (HUVEC) and human aortic smooth muscle cells (HASMC). AGTR1 or AGTR2 mRNA expression were undetectable in HUVEC, whereas HASMC expressed only AGTR1 mRNA. In summary, contrary...... rights reserved....

  17. Low humidity environmental challenge causes barrier disruption and cornification of the mouse corneal epithelium via a c-jun N-terminal kinase 2 (JNK2) pathway.

    Science.gov (United States)

    Pelegrino, F S A; Pflugfelder, S C; De Paiva, C S

    2012-01-01

    Patients with tear dysfunction often experience increased irritation symptoms when subjected to drafty and/or low humidity environmental conditions. The purpose of this study was to investigate the effects of low humidity stress (LHS) on corneal barrier function and expression of cornified envelope (CE) precursor proteins in the epithelium of C57BL/6 and c-jun N-terminal kinase 2 (JNK2) knockout (KO) mice. LHS was induced in both strains by exposure to an air draft for 15 (LHS15D) or 30 days (LHS30D) at a relative humidity LHS15D showed corneal barrier dysfunction, decreased apical corneal epithelial cell area, higher MMP-9 expression and gelatinase activity and increased involucrin and SPRR-2 immunoreactivity in the corneal epithelium compared to NS mice. JNK2KO mice were resistant to LHS-induced corneal barrier disruption. MMP-3,-9,-13, IL-1α, IL-1β, involucrin and SPRR-2a RNA transcripts were significantly increased in C57BL/6 mice at LHS15D, while no change was noted in JNK2KO mice. LHS is capable of altering corneal barrier function, promoting pathologic alteration of the TJ complex and stimulating production of CE proteins by the corneal epithelium. Activation of the JNK2 signaling pathway contributes to corneal epithelial barrier disruption in LHS. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Microultrasound Molecular Imaging of Vascular Endothelial Growth Factor Receptor 2 in a Mouse Model of Tumor Angiogenesis

    Directory of Open Access Journals (Sweden)

    Joshua J. Rychak

    2007-09-01

    Full Text Available High-frequency microultrasound imaging of tumor progression in mice enables noninvasive anatomic and functional imaging at excellent spatial and temporal resolution, although microultrasonography alone does not offer molecular scale data. In the current study, we investigated the use of microbubble ultrasound contrast agents bearing targeting ligands specific for molecular markers of tumor angiogenesis using high-frequency microultrasound imaging. A xenograft tumor model in the mouse was used to image vascular endothelial growth factor receptor 2 (VEGFR-2 expression with microbubbles conjugated to an anti-VEGFR-2 monoclonal antibody or an isotype control. Microultrasound imaging was accomplished at a center frequency of 40 MHz, which provided lateral and axial resolutions of 40 and 90 μm, respectively. The B-mode (two-dimensional mode acoustic signal from microbubbles bound to the molecular target was determined by an ultrasound-based destruction-subtraction scheme. Quantification of the adherent microbubble fraction in nine tumor-bearing mice revealed significant retention of VEGFR-2-targeted microbubbles relative to control-targeted microbubbles. These data demonstrate that contrast-enhanced microultrasound imaging is a useful method for assessing molecular expression of tumor angiogenesis in mice at high resolution.

  19. Immunohistochemical Examination on the Distribution of Cells Expressed Lymphatic Endothelial Marker Podoplanin and LYVE-1 in the Mouse Tongue Tissue

    Science.gov (United States)

    Noda, Yuya; Amano, Ikuko; Hata, Minoru; Kojima, Hiroshi; Sawa, Yoshihiko

    2010-01-01

    The clinical study for lingual disease requires the detailed investigation of the lingual lymphatic network and lymphatic marker-positive cells. Recently, it has been reported that several tissue cells and leukocytes express lymphatic markers, LYVE-1 and podoplanin. This study was aimed to clarify the lingual distribution of cells expressing LYVE-1 and podoplanin. In the mouse tongue, podoplanin is expressed in nerve sheaths, lingual gland myoepithelial cells, and lymphatic vessels. LYVE-1 is expressed in the macrophage marker Mac-1-positive cells as well as lymphatic vessels, while factor-VIII was detected in only blood endothelial cells. α-SMA was detected in vascular smooth muscle and myoepithelial cells. Therefore, identification of lymphatic vessels in lingual glands, the combination of LYVE-1 and factor-VIII, or LYVE-1 and Mac-1 is useful because myoepithelial cells express podoplanin and α-SMA. The immunostaining of factor-VIII on lymphatic vessels was masked by the immunostaining to LYVE-1 or podoplanin because lymphatic vessels express factor-VIII to a far lesser extent than blood vessels. Therefore, except for the salivary glands, the combination of podoplanin and α-SMA, or factor-VIII is useful to identify lymphatic vessels and blood vessels with smooth muscle, or blood capillaries. PMID:20514293

  20. Efficient production of platelets from mouse embryonic stem cells by enforced expression of Gata2 in late hemogenic endothelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Manami [Stem Cell Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510 (Japan); Kitajima, Kenji [Stem Cell Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Kanokoda, Mai [Stem Cell Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510 (Japan); Suzuki, Hidenori [Division of Morphological and Biomolecular Research, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo, 113-8602 (Japan); Miyashita, Kazuya; Nakajima, Marino [Stem Cell Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510 (Japan); Nuriya, Hideko [Core Technology and Research Center, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Kasahara, Kohji [Laboratory of Biomembrane, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Hara, Takahiko, E-mail: hara-tk@igakuken.or.jp [Stem Cell Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kamikitazawa, Setagaya-ku, Tokyo, 156-8506 (Japan); Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510 (Japan)

    2016-06-03

    Platelets are essential for blood circulation and coagulation. Previous study indicated that overexpression of Gata2 in differentiated mouse embryonic stem cells (ESCs) resulted in robust induction of megakaryocytes (Mks). To evaluate platelet production capacity of the Gata2-induced ESC-derived Mks, we generated iGata2-ESC line carrying the doxycycline-inducible Gata2 expression cassette. When doxycycline was added to day 5 hemogenic endothelial cells in the in vitro differentiation culture of iGata2-ESCs, c-Kit{sup −}Tie2{sup −}CD41{sup +} Mks were predominantly generated. These iGata2-ESC-derived Mks efficiently produced CD41{sup +}CD42b{sup +}CD61{sup +} platelets and adhered to fibrinogen-coated glass coverslips in response to thrombin stimulation. Transmission electron microscopy analysis demonstrated that the iGata2-ESC-derived platelets were discoid-shaped with α-granules and an open canalicular system, but were larger than peripheral blood platelets in size. These results demonstrated that an enforced expression of Gata2 in late HECs of differentiated ESCs efficiently promotes megakaryopoiesis followed by platelet production. This study provides valuable information for ex vivo platelet production from human pluripotent stem cells in future. -- Highlights: •Megakaryocytes are efficiently induced by Gata2 from ESC-derived day 5 HECs. •Gata2-induced ESC-derived megakaryocytes are c-Kit{sup −}Tie2{sup −}CD41{sup +}. •Gata2-induced ESC-derived megakaryocytes produce larger discoid-shaped platelets. •Gata2-induced ESC-derived platelets bind fibrinogen upon thrombin stimulation.

  1. Efficient production of platelets from mouse embryonic stem cells by enforced expression of Gata2 in late hemogenic endothelial cells

    International Nuclear Information System (INIS)

    Kawaguchi, Manami; Kitajima, Kenji; Kanokoda, Mai; Suzuki, Hidenori; Miyashita, Kazuya; Nakajima, Marino; Nuriya, Hideko; Kasahara, Kohji; Hara, Takahiko

    2016-01-01

    Platelets are essential for blood circulation and coagulation. Previous study indicated that overexpression of Gata2 in differentiated mouse embryonic stem cells (ESCs) resulted in robust induction of megakaryocytes (Mks). To evaluate platelet production capacity of the Gata2-induced ESC-derived Mks, we generated iGata2-ESC line carrying the doxycycline-inducible Gata2 expression cassette. When doxycycline was added to day 5 hemogenic endothelial cells in the in vitro differentiation culture of iGata2-ESCs, c-Kit − Tie2 − CD41 + Mks were predominantly generated. These iGata2-ESC-derived Mks efficiently produced CD41 + CD42b + CD61 + platelets and adhered to fibrinogen-coated glass coverslips in response to thrombin stimulation. Transmission electron microscopy analysis demonstrated that the iGata2-ESC-derived platelets were discoid-shaped with α-granules and an open canalicular system, but were larger than peripheral blood platelets in size. These results demonstrated that an enforced expression of Gata2 in late HECs of differentiated ESCs efficiently promotes megakaryopoiesis followed by platelet production. This study provides valuable information for ex vivo platelet production from human pluripotent stem cells in future. -- Highlights: •Megakaryocytes are efficiently induced by Gata2 from ESC-derived day 5 HECs. •Gata2-induced ESC-derived megakaryocytes are c-Kit − Tie2 − CD41 + . •Gata2-induced ESC-derived megakaryocytes produce larger discoid-shaped platelets. •Gata2-induced ESC-derived platelets bind fibrinogen upon thrombin stimulation.

  2. Corneal topography

    DEFF Research Database (Denmark)

    Andersen, J.; Koch-Jensen, P.; Østerby, Ole

    1993-01-01

    The central corneal zone is depicted on keratoscope photographs using a small target aperture and a large object distance. Information on the peripheral area is included by employing a hemispherical target with a dense circular and radial pattern. On a 16 mm (R = 8 mm) reference steel sphere the ...

  3. Mutations in LOXHD1, a Recessive-Deafness Locus, Cause Dominant Late-Onset Fuchs Corneal Dystrophy

    Science.gov (United States)

    Riazuddin, S. Amer; Parker, David S.; McGlumphy, Elyse J.; Oh, Edwin C.; Iliff, Benjamin W.; Schmedt, Thore; Jurkunas, Ula; Schleif, Robert; Katsanis, Nicholas; Gottsch, John D.

    2012-01-01

    Fuchs corneal dystrophy (FCD) is a genetic disorder of the corneal endothelium and is the most common cause of corneal transplantation in the United States. Previously, we mapped a late-onset FCD locus, FCD2, on chromosome 18q. Here, we present next-generation sequencing of all coding exons in the FCD2 critical interval in a multigenerational pedigree in which FCD segregates as an autosomal-dominant trait. We identified a missense change in LOXHD1, a gene causing progressive hearing loss in humans, as the sole variant capable of explaining the phenotype in this pedigree. We observed LOXHD1 mRNA in cultured human corneal endothelial cells, whereas antibody staining of both human and mouse corneas showed staining in the corneal epithelium and endothelium. Corneal sections of the original proband were stained for LOXHD1 and demonstrated a distinct increase in antibody punctate staining in the endothelium and Descemet membrane; punctate staining was absent from both normal corneas and FCD corneas negative for causal LOXHD1 mutations. Subsequent interrogation of a cohort of >200 sporadic affected individuals identified another 15 heterozygous missense mutations that were absent from >800 control chromosomes. Furthermore, in silico analyses predicted that these mutations reside on the surface of the protein and are likely to affect the protein's interface and protein-protein interactions. Finally, expression of the familial LOXHD1 mutant allele as well as two sporadic mutations in cells revealed prominent cytoplasmic aggregates reminiscent of the corneal phenotype. All together, our data implicate rare alleles in LOXHD1 in the pathogenesis of FCD and highlight how different mutations in the same locus can potentially produce diverse phenotypes. PMID:22341973

  4. Lineage tracing in the adult mouse corneal epithelium supports the limbal epithelial stem cell hypothesis with intermittent periods of stem cell quiescence

    Directory of Open Access Journals (Sweden)

    Natalie J. Dorà

    2015-11-01

    Full Text Available The limbal epithelial stem cell (LESC hypothesis proposes that LESCs in the corneal limbus maintain the corneal epithelium both during normal homeostasis and wound repair. The alternative corneal epithelial stem cell (CESC hypothesis proposes that LESCs are only involved in wound repair and CESCs in the corneal epithelium itself maintain the corneal epithelium during normal homeostasis. We used tamoxifen-inducible, CreER-loxP lineage tracing to distinguish between these hypotheses. Clones of labelled cells were induced in adult CAGG-CreER;R26R-LacZ reporter mice and their distributions analysed after different chase periods. Short-lived clones, derived from labelled transient amplifying cells, were shed during the chase period and long-lived clones, derived from stem cells, expanded. At 6 weeks, labelled clones appeared at the periphery, extended centripetally as radial stripes and a few reached the centre by 14 weeks. Stripe numbers depended on the age of tamoxifen treatment. Stripes varied in length, some were discontinuous, few reached the centre and almost half had one end at the limbus. Similar stripes extended across the cornea in CAGG-CreER;R26R-mT/mG reporter mice. The distributions of labelled clones are inconsistent with the CESC hypothesis and support the LESC hypothesis if LESCs cycle between phases of activity and quiescence, each lasting several weeks.

  5. Biocompatibility of Poly-ε-caprolactone-hydroxyapatite composite on mouse bone marrow-derived osteoblasts and endothelial cells

    Directory of Open Access Journals (Sweden)

    Wooley Paul H

    2009-02-01

    Full Text Available Abstract Background Tissue-engineered bone may be developed by seeding the cells capable of both osteogenesis and vascularization on biocompatible composite scaffolds. The current study investigated the performance of mice bone marrow-derived osteogenic cells and endothelial cells as seeded on hydroxyapatite (HA and poly-ε-caprolactone (PCL composite scaffolds. Methods Mononuclear cells were induced to osteoblasts and endothelial cells respectively, which were defined by the expression of osteocalcin, alkaline phosphatase (ALP, and deposits of calcium-containing crystal for osteoblasts, or by the expression of vascular endothelial growth factor receptor-2 (VEGFR-2 and von Willebrand factor (vWF, and the formation of a capillary network in Matrigel™ for endothelial cells. Both types of cell were seeded respectively on PCL-HA scaffolds at HA to PCL weight ratio of 1:1, 1:4, or 0:1 and were evaluated using scanning electron microscopy, ALP activity (of osteoblasts and nitric oxide production (of endothelial cells plus the assessment of cell viability. Results The results indicated that HA led to a positive stimulation of osteoblasts viability and ALP activity, while HA showed less influence on endothelial cells viability. An elevated nitric oxide production of endothelial cells was observed in HA-containing group. Conclusion Supplement of HA into PCL improved biocompatible for bone marrow-derived osteoblasts and endothelial cells. The PCL-HA composite integrating with two types of cells may provide a useful system for tissue-engineered bone grafts with vascularization.

  6. Detection and analysis of apoptosis- and autophagy-related miRNAs of mouse vascular endothelial cells in chronic intermittent hypoxia model.

    Science.gov (United States)

    Liu, Kai-Xiong; Chen, Gong-Ping; Lin, Ping-Li; Huang, Jian-Chai; Lin, Xin; Qi, Jia-Chao; Lin, Qi-Chang

    2018-01-15

    Endothelial dysfunction is the main pathogenic mechanism of cardiovascular complications induced by obstructive sleep apnea/hyponea syndrome (OSAHS). Chronic intermittent hypoxia (CIH) is the primary factor of OSAHS-associated endothelial dysfunction. The hypoxia inducible factor (HIF) pathway regulates the expression of downstream target genes and mediates cell apoptosis caused by CIH-induced endothelial injury. miRNAs play extensive and important negative regulatory roles in this process at the post-transcriptional level. However, the regulatory mechanism of miRNAs in CIH tissue models remains unclear. The present study established a mouse aortic endothelial cell model of CIH in an attempt to screen out specific miRNAs by using miRNA chip analysis. It was found that 14 miRNAs were differentially expressed. Of them, 6 were significantly different and verified by quantitative real-time PCR (Q-PCR), of which four were up-regulated and two were down-regulated markedly. To gain an unbiased global perspective on subsequent regulation by altered miRNAs, we established signaling networks by GO to predict the target genes of the 6 miRNAs. It was found that the 6 identified miRNAs were apoptosis- or autophagy-related target genes. Down-regulation of miR-193 inhibits CIH induced endothelial injury and apoptosis- or autophagy-related protein expression. In conclusion, our results showed that CIH could induce differential expression of miRNAs, and alteration in the miRNA expression pattern was associated with the expression of apoptosis- or autophagy-related genes. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Polysaccharide coating of human corneal endothelium

    DEFF Research Database (Denmark)

    Schroder, H D; Sperling, S

    1977-01-01

    Electron microscopy revealed the presence of a 600-1500 A thick layer of polysaccharide on the surface of human corneal endothelial cells. The surface layer was visualized by combined fixation and staining in a mixture of ruthenium red and osmium tetroxide. The coating material was stable for at ...... for at least 39 h post mortem and was retained on disintegrating cells....

  8. Visualization of endothelial cell cycle dynamics in mouse using the Flt-1/eGFP-anillin system.

    Science.gov (United States)

    Herz, Katia; Becker, Alexandra; Shi, Chenyue; Ema, Masatsugo; Takahashi, Satoru; Potente, Michael; Hesse, Michael; Fleischmann, Bernd K; Wenzel, Daniela

    2018-05-01

    Endothelial cell proliferation is a key process during vascular growth but its kinetics could only be assessed in vitro or ex vivo so far. To enable the monitoring and quantification of cell cycle kinetics in vivo, we have generated transgenic mice expressing an eGFP-anillin construct under control of the endothelial-specific Flt-1 promoter. This construct labels the nuclei of endothelial cells in late G1, S and G2 phase and changes its localization during the different stages of M phase, thereby enabling the monitoring of EC proliferation and cytokinesis. In Flt-1/eGFP-anillin mice, we found eGFP + signals specifically in Ki67 + /PECAM + endothelial cells during vascular development. Quantification using this cell cycle reporter in embryos revealed a decline in endothelial cell proliferation between E9.5 to E12.5. By time-lapse microscopy, we determined the length of different cell cycle phases in embryonic endothelial cells in vivo and found a M phase duration of about 80 min with 2/3 covering karyokinesis and 1/3 cytokinesis. Thus, we have generated a versatile transgenic system for the accurate assessment of endothelial cell cycle dynamics in vitro and in vivo.

  9. Involvement of insulin-degrading enzyme in insulin- and atrial natriuretic peptide-sensitive internalization of amyloid-β peptide in mouse brain capillary endothelial cells.

    Science.gov (United States)

    Ito, Shingo; Ohtsuki, Sumio; Murata, Sho; Katsukura, Yuki; Suzuki, Hiroya; Funaki, Miho; Tachikawa, Masanori; Terasaki, Tetsuya

    2014-01-01

    Cerebral clearance of amyloid-β peptide (Aβ), which is implicated in Alzheimer's disease, involves elimination across the blood-brain barrier (BBB), and we previously showed that an insulin-sensitive process is involved in the case of Aβ1-40. The purpose of this study was to clarify the molecular mechanism of the insulin-sensitive Aβ1-40 elimination across mouse BBB. An in vivo cerebral microinjection study demonstrated that [125I]hAβ1-40 elimination from mouse brain was inhibited by human natriuretic peptide (hANP), and [125I]hANP elimination was inhibited by hAβ1-40, suggesting that hAβ1-40 and hANP share a common elimination process. Internalization of [125I]hAβ1-40 into cultured mouse brain capillary endothelial cells (TM-BBB4) was significantly inhibited by either insulin, hANP, other natriuretic peptides or insulin-degrading enzyme (IDE) inhibitors, but was not inhibited by phosphoramidon or thiorphan. Although we have reported the involvement of natriuretic peptide receptor C (Npr-C) in hANP internalization, cells stably expressing Npr-C internalized [125I]hANP but not [125I]hAβ1-40, suggesting that there is no direct interaction between Npr-C and hAβ1-40. IDE was detected in plasma membrane of TM-BBB4 cells, and internalization of [125I]hAβ1-40 by TM-BBB4 cells was reduced by IDE-targeted siRNAs. We conclude that elimination of hAβ1-40 from mouse brain across the BBB involves an insulin- and ANP-sensitive process, mediated by IDE expressed in brain capillary endothelial cells.

  10. Corneal thickness: measurement and implications.

    Science.gov (United States)

    Ehlers, Niels; Hjortdal, Jesper

    2004-03-01

    The thickness of the cornea was reported in more than 100-year-old textbooks on physiological optics (Helmholtz, Gullstrand). Physiological interest was revived in the 1950s by David Maurice, and over the next 50 years, this 'simple' biological parameter has been studied extensively. Several techniques for its measurement have been described and physiological and clinical significance have been studied. In this review, the different methods and techniques of measurement are briefly presented (optical, ultrasound). While the corneal thickness of many animals are the same over a considerable part of the surface, in the human cornea anterior and posterior curvature are not concentric giving rise to a problem of definition. Based on this the precision and accuracy of determining the central corneal thickness are discussed. Changes in corneal thickness reflects changes in function of the boundary layers, in particular the endothelial barrier. The absolute value of thickness is of importance for the estimation of IOP but also in diagnosis of corneal and systemic disorders. Finally it is discussed to what extent the thickness is a biometric parameter of significance, e.g. in the progression of myopia or in the development of retinal detachment.

  11. [The status quo and expectation of corneal research in China].

    Science.gov (United States)

    Shi, Weiyun; Xie, Lixin

    2014-09-01

    In China, corneal disease is currently the second leading cause of blindness. Severe donor shortage, insufficient technique supports and promotion, and the lack of corneal disease specialists due to poor systematic training are all urgent problems to be resolved. The last 5 years have witnessed a considerable progress in basic and clinical researches of corneal disease. Investigations on the pathogenesis and treatment of fungal keratitis have won an international reputation. Results from the study of corneal reconstruction with tissue-engineered and acellular matrix corneas have been tested in clinical trials with good preliminary performance. Moreover, the clinical researches of corneal refractive surgery have kept pace with the latest international progresses. However, Descemet's membrane endothelial keratoplasty needs further promotion, and the development and application of keratoprosthesis remains a blank. Although keratoprosthesis and corneal collagen cross-linking have been widely applied in Europe with satisfactory clinical efficacy, they are still under assessment by China Food and Drug Administration for approval of use.

  12. Inhibition of Vascular Endothelial Growth Factor A and Hypoxia-Inducible Factor 1α Maximizes the Effects of Radiation in Sarcoma Mouse Models Through Destruction of Tumor Vasculature

    International Nuclear Information System (INIS)

    Lee, Hae-June; Yoon, Changhwan; Park, Do Joong; Kim, Yeo-Jung; Schmidt, Benjamin; Lee, Yoon-Jin; Tap, William D.; Eisinger-Mathason, T.S. Karin; Choy, Edwin; Kirsch, David G.; Simon, M. Celeste

    2015-01-01

    Purpose: To examine the addition of genetic or pharmacologic inhibition of hypoxia-inducible factor 1α (HIF-1α) to radiation therapy (RT) and vascular endothelial growth factor A (VEGF-A) inhibition (ie trimodality therapy) for soft-tissue sarcoma. Methods and Materials: Hypoxia-inducible factor 1α was inhibited using short hairpin RNA or low metronomic doses of doxorubicin, which blocks HIF-1α binding to DNA. Trimodality therapy was examined in a mouse xenograft model and a genetically engineered mouse model of sarcoma, as well as in vitro in tumor endothelial cells (ECs) and 4 sarcoma cell lines. Results: In both mouse models, any monotherapy or bimodality therapy resulted in tumor growth beyond 250 mm 3 within the 12-day treatment period, but trimodality therapy with RT, VEGF-A inhibition, and HIF-1α inhibition kept tumors at <250 mm 3 for up to 30 days. Trimodality therapy on tumors reduced HIF-1α activity as measured by expression of nuclear HIF-1α by 87% to 95% compared with RT alone, and cytoplasmic carbonic anhydrase 9 by 79% to 82%. Trimodality therapy also increased EC-specific apoptosis 2- to 4-fold more than RT alone and reduced microvessel density by 75% to 82%. When tumor ECs were treated in vitro with trimodality therapy under hypoxia, there were significant decreases in proliferation and colony formation and increases in DNA damage (as measured by Comet assay and γH2AX expression) and apoptosis (as measured by cleaved caspase 3 expression). Trimodality therapy had much less pronounced effects when 4 sarcoma cell lines were examined in these same assays. Conclusions: Inhibition of HIF-1α is highly effective when combined with RT and VEGF-A inhibition in blocking sarcoma growth by maximizing DNA damage and apoptosis in tumor ECs, leading to loss of tumor vasculature

  13. Inhibition of Vascular Endothelial Growth Factor A and Hypoxia-Inducible Factor 1α Maximizes the Effects of Radiation in Sarcoma Mouse Models Through Destruction of Tumor Vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hae-June [Department of Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Yoon, Changhwan [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Park, Do Joong [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Surgery, Seoul National University Bundang Hospital, Sungnam (Korea, Republic of); Kim, Yeo-Jung [Abramson Family Cancer Research Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Schmidt, Benjamin [Department of Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Lee, Yoon-Jin [Department of Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Tap, William D. [Department of Medicine, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Eisinger-Mathason, T.S. Karin [Abramson Family Cancer Research Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Choy, Edwin [Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Kirsch, David G. [Department of Pharmacology and Cancer Biology, Duke University Medical Center, Durham, North Carolina (United States); Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Simon, M. Celeste [Abramson Family Cancer Research Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Howard Hughes Medical Institute (United States); and others

    2015-03-01

    Purpose: To examine the addition of genetic or pharmacologic inhibition of hypoxia-inducible factor 1α (HIF-1α) to radiation therapy (RT) and vascular endothelial growth factor A (VEGF-A) inhibition (ie trimodality therapy) for soft-tissue sarcoma. Methods and Materials: Hypoxia-inducible factor 1α was inhibited using short hairpin RNA or low metronomic doses of doxorubicin, which blocks HIF-1α binding to DNA. Trimodality therapy was examined in a mouse xenograft model and a genetically engineered mouse model of sarcoma, as well as in vitro in tumor endothelial cells (ECs) and 4 sarcoma cell lines. Results: In both mouse models, any monotherapy or bimodality therapy resulted in tumor growth beyond 250 mm{sup 3} within the 12-day treatment period, but trimodality therapy with RT, VEGF-A inhibition, and HIF-1α inhibition kept tumors at <250 mm{sup 3} for up to 30 days. Trimodality therapy on tumors reduced HIF-1α activity as measured by expression of nuclear HIF-1α by 87% to 95% compared with RT alone, and cytoplasmic carbonic anhydrase 9 by 79% to 82%. Trimodality therapy also increased EC-specific apoptosis 2- to 4-fold more than RT alone and reduced microvessel density by 75% to 82%. When tumor ECs were treated in vitro with trimodality therapy under hypoxia, there were significant decreases in proliferation and colony formation and increases in DNA damage (as measured by Comet assay and γH2AX expression) and apoptosis (as measured by cleaved caspase 3 expression). Trimodality therapy had much less pronounced effects when 4 sarcoma cell lines were examined in these same assays. Conclusions: Inhibition of HIF-1α is highly effective when combined with RT and VEGF-A inhibition in blocking sarcoma growth by maximizing DNA damage and apoptosis in tumor ECs, leading to loss of tumor vasculature.

  14. A rapid separation of two distinct populations of mouse corneal epithelial cells with limbal stem cell characteristics by centrifugation on percoll gradient

    Czech Academy of Sciences Publication Activity Database

    Krulová, Magdalena; Pokorná, Kateřina; Lenčová, Anna; Frič, Jan; Zajícová, Alena; Filipec, Martin; Forrester, J. V.; Holáň, Vladimír

    2008-01-01

    Roč. 49, č. 9 (2008), s. 3903-3908 ISSN 0146-0404 R&D Projects: GA AV ČR KAN200520804; GA MŠk 1M0506; GA ČR GD310/08/H077 Institutional research plan: CEZ:AV0Z50520514 Keywords : limbal stem cells * Percoll gradient * corneal epithelial cells Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.582, year: 2008

  15. Nerve growth factor regulates neurolymphatic remodeling during corneal inflammation and resolution.

    Directory of Open Access Journals (Sweden)

    Darci M Fink

    Full Text Available The cellular and physiologic mechanisms that regulate the resolution of inflammation remain poorly defined despite their widespread importance in improving inflammatory disease outcomes. We studied the resolution of two cardinal signs of inflammation-pain and swelling-by investigating molecular mechanisms that regulate neural and lymphatic vessel remodeling during the resolution of corneal inflammation. A mouse model of corneal inflammation and wound recovery was developed to study this process in vivo. Administration of nerve growth factor (NGF increased pain sensation and inhibited neural remodeling and lymphatic vessel regression processes during wound recovery. A complementary in vivo approach, the corneal micropocket assay, revealed that NGF-laden pellets stimulated lymphangiogenesis and increased protein levels of VEGF-C. Adult human dermal lymphatic endothelial cells did not express canonical NGF receptors TrkA and p75NTR or activate downstream MAPK- or Akt-pathway effectors in the presence of NGF, although NGF treatment increased their migratory and tubulogenesis capacities in vitro. Blockade of the VEGF-R2/R3 signaling pathway ablated NGF-mediated lymphangiogenesis in vivo. These findings suggest a hierarchical relationship with NGF functioning upstream of the VEGF family members, particularly VEGF-C, to stimulate lymphangiogenesis. Taken together, these studies show that NGF stimulates lymphangiogenesis and that NGF may act as a pathogenic factor that negatively regulates the normal neural and lymphatic vascular remodeling events that accompany wound recovery.

  16. 1,4-Anhydro-4-seleno-d-talitol (SeTal) protects endothelial function in the mouse aorta by scavenging superoxide radicals under conditions of acute oxidative stress

    DEFF Research Database (Denmark)

    Ng, Hooi Hooi; Leo, Chen Huei; O'Sullivan, Kelly

    2017-01-01

    and decreased basal nitric oxide (NO) availability. SeTal (1mM) co-treatment prevented high glucose-induced endothelial dysfunction and oxidative stress in the mouse aorta. The presence of a cyclooxygenase inhibitor, indomethacin significantly improved the sensitivity to ACh in high glucose-treated aortae......, but had no effect in SeTal-treated aortae. Our data show that SeTal has potent antioxidant activity in isolated mouse aortae and prevents high glucose-induced endothelial dysfunction by decreasing superoxide levels, increasing basal NO availability and normalising the contribution of vasoconstrictor......Hyperglycaemia increases the generation of reactive oxidants in blood vessels and is a major cause of endothelial dysfunction. A water-soluble selenium-containing sugar (1,4-Anhydro-4-seleno-d-talitol, SeTal) has potent antioxidant activity in vitro and is a promising treatment to accelerate wound...

  17. Differential effects of vascular endothelial growth factor A isoforms in a mouse brain metastasis model of human melanoma.

    NARCIS (Netherlands)

    Kusters, B.; Waal, R.M.W. de; Wesseling, P.; Verrijp, K.; Maass, C.N.; Heerschap, A.; Barentsz, J.O.; Sweep, C.G.J.; Ruiter, D.J.; Leenders, W.P.J.

    2003-01-01

    We reported previously that vascular endothelial growth factor isoform A (VEGF-A) expression by Mel57 human melanoma cells led to tumor progression in a murine brain metastasis model in an angiogenesis-independent fashion by dilation of co-opted, pre-existing vessels and concomitant enhanced blood

  18. One amino acid in mouse activated factor VII defines its endothelial protein C receptor (EPCR) binding and modulates its EPCR-dependent hemostatic activity in vivo.

    Science.gov (United States)

    Pavani, G; Zintner, S M; Ivanciu, L; Small, J C; Stafford, K A; Szeto, J H; Margaritis, P

    2017-03-01

    Essentials The lack of factor (F) VIIa-endothelial protein C receptor (EPCR) binding in mice is unresolved. A single substitution of Leu4 to Phe in mouse FVIIa (mFVIIa) enables its interaction with EPCR. mFVIIa with a Phe4 shows EPCR binding-dependent enhanced hemostatic function in vivo vs. mFVIIa. Defining the FVIIa-EPCR interaction in mice allows for further investigating its biology in vivo. Background Human activated factor VII (hFVIIa), which is used in hemophilia treatment, binds to the endothelial protein C (PC) receptor (EPCR) with unclear hemostatic consequences. Interestingly, mice lack the activated FVII (FVIIa)-EPCR interaction. Therefore, to investigate the hemostatic consequences of this interaction in hemophilia, we previously engineered a mouse FVIIa (mFVIIa) molecule that bound mouse EPCR (mEPCR) by using three substitutions from mouse PC (mPC), i.e. Leu4→Phe, Leu8→Met, and Trp9→Arg. The resulting molecule, mFVIIa-FMR, modeled the EPCR-binding properties of hFVIIa and showed enhanced hemostatic capacity in hemophilic mice versus mFVIIa. These data implied a role of EPCR in the action of hFVIIa in hemophilia treatment. However, the substitutions in mFVIIa-FMR only broadly defined the sequence determinants for its mEPCR interaction and enhanced function in vivo. Objectives To determine the individual contributions of mPC Phe4, Met8 and Arg9 to the in vitro/in vivo properties of mFVIIa-FMR. Methods The mEPCR-binding properties of single amino acid variants of mFVIIa or mPC at position 4, 8 or 9 were investigated. Results and conclusions Phe4 in mFVIIa or mPC was solely critical for interaction with mEPCR. In hemophilic mice, administration of mFVIIa harboring a Phe4 resulted in a 1.9-2.5-fold increased hemostatic capacity versus mFVIIa that was EPCR binding-dependent. This recapitulated previous observations made with triple-mutant mFVIIa-FMR. As Leu8 is crucial for hFVIIa-EPCR binding, we describe the sequence divergence of this interaction in

  19. Arsenic augments the uptake of oxidized LDL by upregulating the expression of lectin-like oxidized LDL receptor in mouse aortic endothelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Hossain, Ekhtear [Department of Biochemistry, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan); Ota, Akinobu, E-mail: aota@aichi-med-u.ac.jp [Department of Biochemistry, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan); Karnan, Sivasundaram; Damdindorj, Lkhagvasuren [Department of Biochemistry, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan); Takahashi, Miyuki [Department of Biochemistry, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan); Division of Hematology, Department of Internal Medicine, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan); Konishi, Yuko; Konishi, Hiroyuki; Hosokawa, Yoshitaka [Department of Biochemistry, Aichi Medical University School of Medicine, Nagakute, Aichi (Japan)

    2013-12-15

    Although chronic arsenic exposure is a well-known risk factor for cardiovascular diseases, including atherosclerosis, the molecular mechanism underlying arsenic-induced atherosclerosis remains obscure. Therefore, this study aimed to elucidate this molecular mechanism. We examined changes in the mRNA level of the lectin-like oxidized LDL (oxLDL) receptor (LOX-1) in a mouse aortic endothelial cell line, END-D, after sodium arsenite (SA) treatment. SA treatment significantly upregulated LOX-1 mRNA expression; this finding was also verified at the protein expression level. Flow cytometry and fluorescence microscopy analyses showed that the cellular uptake of fluorescence (Dil)-labeled oxLDL was significantly augmented with SA treatment. In addition, an anti-LOX-1 antibody completely abrogated the augmented uptake of Dil-oxLDL. We observed that SA increased the levels of the phosphorylated forms of nuclear factor of kappa light polypeptide gene enhancer in B cells (NF-κB)/p65. SA-induced upregulation of LOX-1 protein expression was clearly prevented by treatment with an antioxidant, N-acetylcysteine (NAC), or an NF-κB inhibitor, caffeic acid phenethylester (CAPE). Furthermore, SA-augmented uptake of Dil-oxLDL was also prevented by treatment with NAC or CAPE. Taken together, our results indicate that arsenic upregulates LOX-1 expression through the reactive oxygen species-mediated NF-κB signaling pathway, followed by augmented cellular oxLDL uptake, thus highlighting a critical role of the aberrant LOX-1 signaling pathway in the pathogenesis of arsenic-induced atherosclerosis. - Highlights: • Sodium arsenite (SA) increases LOX-1 expression in mouse aortic endothelial cells. • SA enhances cellular uptake of oxidized LDL in dose-dependent manner. • SA-induced ROS generation enhances phosphorylation of NF-κB. • SA upregulates LOX-1 expression through ROS-activated NF-κB signaling pathway.

  20. Corneal rat-to-mouse xenotransplantation and the effects of anti-CD4 or anti-CD8 treatment on cytokine and nitric oxide production

    Czech Academy of Sciences Publication Activity Database

    Pindjáková, Jana; Vítová, Andrea; Krulová, Magdalena; Zajícová, Alena; Filipec, M.; Holáň, Vladimír

    2005-01-01

    Roč. 18, č. 7 (2005), s. 854-862 ISSN 0934-0874 R&D Projects: GA MZd(CZ) NR7816; GA MZd(CZ) NI7531; GA ČR GP310/02/D162; GA ČR(CZ) GD310/03/H147; GA MŠk(CZ) ME 300; GA AV ČR KSK5020115 Institutional research plan: CEZ:AV0Z5052915 Keywords : corneal xenotransplantation * cytokines * nitric oxide Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.797, year: 2005

  1. Evaluation of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy.

    Science.gov (United States)

    Ari, Seyhmus; Nergiz, Yusuf; Aksit, Ihsan; Sahin, Alparslan; Cingu, Kursat; Caca, Ihsan

    2015-03-01

    To evaluate the effects of intracameral injection of ranibizumab and bevacizumab on the corneal endothelium by scanning electron microscopy (SEM). Twenty-eight female rabbits were randomly divided into four equal groups. Rabbits in groups 1 and 2 underwent intracameral injection of 1 mg/0.1 mL and 0.5 mg/0.05 mL ranibizumab, respectively; group 3 was injected with 1.25 mg/0.05 mL bevacizumab. All three groups were injected with a balanced salt solution (BSS) into the anterior chamber of the left (fellow) eye. None of the rabbits in group 4 underwent an injection. Corneal thickness and intraocular pressure were measured before the injections, on the first day, and in the first month after injection. The rabbits were sacrificed and corneal tissues were excised in the first month after injection. Specular microscopy was used for the corneal endothelial cell count. Endothelial cell density was assessed and comparisons drawn between the groups and the control. Micrographs were recorded for SEM examination. The structure of the corneal endothelial cells, the junctional area of the cell membrane, the distribution of microvillus, and the cell morphology of the eyes that underwent intracameral injection of vascular endothelial growth factor (VEGF), BSS, and the control group were compared. Corneal thickness and intraocular pressure were not significantly different between the groups that underwent anti-VEGF or BSS injection and the control group on the first day and in the first month of injection. The corneal endothelial cell count was significantly diminished in all three groups; predominantly in group 1 and 2 (P<0.05). The SEM examination revealed normal corneal endothelial histology in group 3 and the control group. Eyes in group 1 exhibited indistinctness of corneal endothelial cell borders, microvillus loss in the luminal surface, excessive blebbing, and disintegration of intercellular junctions. In group 2, the cell structure of the corneal endothelium

  2. Triptolide Suppresses Alkali Burn-Induced Corneal Angiogenesis Along with a Downregulation of VEGFA and VEGFC Expression.

    Science.gov (United States)

    Wang, Geng; Li, Na; Lv, Xiaohong; Ahmed, Naila; Li, Xinlei; Liu, Huidong; Ma, Jing; Zhang, Yafang

    2017-07-01

    Triptolide (TPL) is an active compound extracted from a Chinese herbal medicine tripterygium wilfordii Hook. f. (Celastraceae), which has been used as an anti-inflammatory drug for years. It also inhibits the growth and proliferation of different types of cancer cells. The inhibitory effect of TPL on angiogenesis after chemical-induced corneal inflammation was studied in vivo. The effects of TPL on the proliferation, apoptosis, migration, and tube formation of rat aortic endothelial cells (RAECs) were studied in vitro. Cell proliferation and apoptosis were measured by MTT assay and flow cytometry, respectively. Migration was analyzed using the scratch wound healing assay and transwell assay. Tube formation assay was used to examine angiogenesis. Real-time PCR and Western blot were used to determine the expression of vascular endothelial growth factor A (VEGFA) and VEGFC. To study the in vivo effects of TPL, the mouse model of alkali burn-induced corneal angiogenesis was used. The angiogenesis was analyzed by determining the density of the newly generated blood vessels in corneas. We found that TPL induced apoptosis and inhibited the proliferation of RAECs in a dose-dependent manner. TPL inhibited migration and tube formation of RAECs and decreased the expression of VEGFA and VEGFC in vitro. Furthermore, TPL suppressed alkali burn-induced corneal angiogenesis and inhibited the expression of VEGFA and VEGFC in corneas in vivo. In conclusion, topical TPL as a pharmacological agent has the ability to reduce angiogenesis in cornea and may have clinical indications for the treatment of corneal angiogenesis diseases which have to be further explored. Anat Rec, 300:1348-1355, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Progesterone amplifies oxidative stress signal and promotes NO production via H2O2 in mouse kidney arterial endothelial cells.

    Science.gov (United States)

    Yuan, Xiao-Hua; Fan, Yang-Yang; Yang, Chun-Rong; Gao, Xiao-Rui; Zhang, Li-Li; Hu, Ying; Wang, Ya-Qin; Jun, Hu

    2016-01-01

    The role of progesterone on the cardiovascular system is controversial. Our present research is to specify the effect of progesterone on arterial endothelial cells in response to oxidative stress. Our result showed that H2O2 (150 μM and 300 μM) induced cellular antioxidant response. Glutathione (GSH) production and the activity of Glutathione peroxidase (GPx) were increased in H2O2-treated group. The expression of glutamate cysteine ligase catalytic subunit (GCLC) and modifier subunit (GCLM) was induced in response to H2O2. However, progesterone absolutely abolished the antioxidant response through increasing ROS level, inhibiting the activity of Glutathione peroxidase (GPx), decreasing GSH level and reducing expression of GClC and GCLM. In our study, H2O2 induced nitrogen monoxide (NO) production and endothelial nitric oxide synthase (eNOS) expression, and progesterone promoted H2O2-induced NO production. Progesterone increased H2O2-induced expression of hypoxia inducible factor-α (HIFα) which in turn regulated eNOS expression and NO synthesis. Further study demonstrated that progesterone increased H2O2 concentration of culture medium which may contribute to NO synthesis. Exogenous GSH decreased the content of H2O2 of culture medium pretreated by progesterone combined with H2O2 or progesterone alone. GSH also inhibited expression of HIFα and eNOS, and abolished NO synthesis. Collectively, our study demonstrated for the first time that progesterone inhibited cellular antioxidant effect and increased oxidative stress, promoted NO production of arterial endothelial cells, which may be due to the increasing H2O2 concentration and amplified oxidative stress signal. Copyright © 2015. Published by Elsevier Ltd.

  4. The matricellular protein TSP1 promotes human and mouse endothelial cell senescence through CD47 and Nox1.

    Science.gov (United States)

    Meijles, Daniel N; Sahoo, Sanghamitra; Al Ghouleh, Imad; Amaral, Jefferson H; Bienes-Martinez, Raquel; Knupp, Heather E; Attaran, Shireen; Sembrat, John C; Nouraie, Seyed M; Rojas, Mauricio M; Novelli, Enrico M; Gladwin, Mark T; Isenberg, Jeffrey S; Cifuentes-Pagano, Eugenia; Pagano, Patrick J

    2017-10-17

    Senescent cells withdraw from the cell cycle and do not proliferate. The prevalence of senescent compared to normally functioning parenchymal cells increases with age, impairing tissue and organ homeostasis. A contentious principle governing this process has been the redox theory of aging. We linked matricellular protein thrombospondin 1 (TSP1) and its receptor CD47 to the activation of NADPH oxidase 1 (Nox1), but not of the other closely related Nox isoforms, and associated oxidative stress, and to senescence in human cells and aged tissue. In human endothelial cells, TSP1 promoted senescence and attenuated cell cycle progression and proliferation. At the molecular level, TSP1 increased Nox1-dependent generation of reactive oxygen species (ROS), leading to the increased abundance of the transcription factor p53. p53 mediated a DNA damage response that led to senescence through Rb and p21 cip , both of which inhibit cell cycle progression. Nox1 inhibition blocked the ability of TSP1 to increase p53 nuclear localization and p21 cip abundance and its ability to promote senescence. Mice lacking TSP1 showed decreases in ROS production, p21 cip expression, p53 activity, and aging-induced senescence. Conversely, lung tissue from aging humans displayed increases in the abundance of vascular TSP1, Nox1, p53, and p21 cip Finally, genetic ablation or pharmacological blockade of Nox1 in human endothelial cells attenuated TSP1-mediated ROS generation, restored cell cycle progression, and protected against senescence. Together, our results provide insights into the functional interplay between TSP1 and Nox1 in the regulation of endothelial senescence and suggest potential targets for controlling the aging process at the molecular level. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  5. Differential expression of the Slc4 bicarbonate transporter family in murine corneal endothelium and cell culture.

    Science.gov (United States)

    Shei, William; Liu, Jun; Htoon, Hla M; Aung, Tin; Vithana, Eranga N

    2013-01-01

    To characterize the relative expression levels of all the solute carrier 4 (Slc4) transporter family members (Slc4a1-Slc4a11) in murine corneal endothelium using real-time quantitative (qPCR), to identify further important members besides Slc4a11 and Slc4a4, and to explore how close to the baseline levels the gene expressions remain after cells have been subjected to expansion and culture. Descemet's membrane-endothelial layers of 8-10-week-old C57BL6 mice were stripped from corneas and used for both primary cell culture and direct RNA extraction. Total RNA (from uncultured cells as well as cultured cells at passages 2 and 7) was reverse transcribed, and the cDNA was used for real time qPCR using specific primers for all the Slc4 family members. The geNorm method was applied to determine the most stable housekeeping genes and normalization factor, which was calculated from multiple housekeeping genes for more accurate and robust quantification. qPCR analyses revealed that all Slc4 bicarbonate transporter family members were expressed in mouse corneal endothelium. Slc4a11 showed the highest expression, which was approximately three times higher than that of Slc4a4 (3.4±0.3; p=0.004). All Slc4 genes were also expressed in cultured cells, and interestingly, the expression of Slc4a11 in cultured cells was significantly reduced by approximately 20-fold (0.05±0.001; p=0.000001) in early passage and by approximately sevenfold (0.14±0.002; p=0.000002) in late passage cells. Given the known involvement of SLC4A4 and SLC4A11 in corneal dystrophies, we speculate that the other two highly expressed genes in the uncultured corneal endothelium, SLC4A2 and SLC4A7, are worthy of being considered as potential candidate genes for corneal endothelial diseases. Moreover, as cell culture can affect expression levels of Slc4 genes, caution and careful design of experiments are necessary when undertaking studies of Slc4-mediated ion transport in cultured cells.

  6. Comparison of Endothelial Cell Loss by Specular Microscopy ...

    African Journals Online (AJOL)

    Endothelial cell loss was also compared in phacoemulsification group by temporal clear corneal incision (CCI) and by superior scleral incision (SI) technique. ..... vs manual sutureless small-incision extracapsular cataract surgery in Nepal.

  7. Intimal cushions and endothelial nuclear elongation around mouse aortic branches and their spatial correspondence with patterns of lipid deposition

    Science.gov (United States)

    Bond, Andrew R.; Ni, Chih-Wen; Jo, Hanjoong

    2010-01-01

    Spatial variation in hemodynamic stresses acting on the arterial wall may explain the nonuniform distribution of atherosclerosis. In thoracic aortas of LDL receptor/apolipoprotein E double knockout mice, lesions develop preferentially around the entire circumference of intercostal branch ostia, regardless of age, with the highest prevalence occurring upstream. Additional chevron-shaped lesions occur further upstream of the ostia. This pattern differs from the age-related ones occurring in people and rabbits. In the present study, patterns of near-wall blood flow around intercostal ostia in wild-type mice were estimated from the morphology of endothelial nuclei, which were shown in vitro to elongate in response to elevated shear stress and to align with the flow, and wall structure was assessed from confocal and scanning electron microscopy. A triangular intimal cushion surrounded the upstream part of most ostia. Nuclear length-to-width ratios were lowest over this cushion and highest at the sides of branches, regardless of age. Nuclear orientations were consistent with flow diverging around the branch. The pattern of nuclear morphology differed from the age-related ones observed in rabbits. The intimal cushion and the distribution of shear stress inferred from these observations can partly account for the pattern of lesions observed in knockout mice. Nuclear elongation in nonbranch regions was approximately constant across animals of different size, demonstrating the existence of a mechanism by which endothelial cells compensate for the dependence of mean aortic wall shear stress on body mass. PMID:19933414

  8. Equine corneal stromal abscesses

    DEFF Research Database (Denmark)

    Henriksen, M. D. L.; Andersen, P. H.; Plummer, C. E.

    2013-01-01

    The last 30 years have seen many changes in the understanding of the pathogenesis and treatment of equine corneal stromal abscesses (SAs). Stromal abscesses were previously considered an eye problem related to corneal bacterial infection, equine recurrent uveitis, corneal microtrauma and corneal....... Medical and surgical treatments are now directed towards elimination of fungal and bacterial infections, reduction and replacement of diseased corneal stroma, and suppression of iridocyclitis. If the abscess and anterior uveitis do not respond satisfactorily to medical therapy, full thickness or split...

  9. Human tears reveal insights into corneal neovascularization.

    Science.gov (United States)

    Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.

  10. miR-214-Dependent Increase of PHLPP2 Levels Mediates the Impairment of Insulin-Stimulated Akt Activation in Mouse Aortic Endothelial Cells Exposed to Methylglyoxal

    Directory of Open Access Journals (Sweden)

    Cecilia Nigro

    2018-02-01

    Full Text Available Evidence has been provided linking microRNAs (miRNAs and diabetic complications, by the regulation of molecular pathways, including insulin-signaling, involved in the pathophysiology of vascular dysfunction. Methylglyoxal (MGO accumulates in diabetes and is associated with cardiovascular complications. This study aims to analyze the contribution of miRNAs in the MGO-induced damaging effect on insulin responsiveness in mouse aortic endothelial cells (MAECs. miRNA modulation was performed by transfection of specific miRNA mimics and inhibitors in MAECs, treated or not with MGO. miRNA-target protein levels were evaluated by Western blot. PH domain leucine-rich repeat protein phosphatase 2 (PHLPP2 regulation by miR-214 was tested by luciferase assays and by the use of a target protector specific for miR-214 on PHLPP2-3′UTR. This study reveals a 4-fold increase of PHLPP2 in MGO-treated MAECs. PHLPP2 levels inversely correlate with miR-214 modulation. Moreover, miR-214 overexpression is able to reduce PHLPP2 levels in MGO-treated MAECs. Interestingly, a direct regulation of PHLPP2 is proved to be dependent by miR-214. Finally, the inhibition of miR-214 impairs the insulin-dependent Akt activation, while its overexpression rescues the insulin effect on Akt activation in MGO-treated MAECs. In conclusion, this study shows that PHLPP2 is a target of miR-214 in MAECs, and identifies miR-214 downregulation as a contributing factor to MGO-induced endothelial insulin-resistance.

  11. Overexpression of catalase delays G0/G1- to S-phase transition during cell cycle progression in mouse aortic endothelial cells.

    Science.gov (United States)

    Onumah, Ogbeyalu E; Jules, George E; Zhao, Yanfeng; Zhou, LiChun; Yang, Hong; Guo, ZhongMao

    2009-06-15

    Although it is understood that hydrogen peroxide (H(2)O(2)) promotes cellular proliferation, little is known about its role in endothelial cell cycle progression. To assess the regulatory role of endogenously produced H(2)O(2) in cell cycle progression, we studied the cell cycle progression in mouse aortic endothelial cells (MAECs) obtained from mice overexpressing a human catalase transgene (hCatTg), which destroys H(2)O(2). The hCatTg MAECs displayed a prolonged doubling time compared to wild-type controls (44.0 +/- 4.7 h versus 28.6 +/- 0.8 h, pcatalase inhibitor, prevented the observed diminished growth rate in hCatTg MAECs. Inhibition of catalase activity with aminotriazole abrogated catalase overexpression-induced antiproliferative action. Flow cytometry analysis indicated that the prolonged doubling time was principally due to an extended G(0)/G(1) phase in hCatTg MAECs compared to the wild-type cells (25.0 +/- 0.9 h versus 15.9 +/- 1.4 h, pinhibitors, p21 and p27, which inhibit the Cdk activity required for the G(0)/G(1)- to S-phase transition. Knockdown of p21 and/or p27 attenuated the antiproliferative effect of catalase overexpression in MAECs. These results, together with the fact that catalase is an H(2)O(2) scavenger, suggest that endogenously produced H(2)O(2) mediates MAEC proliferation by fostering the transition from G(0)/G(1) to S phase.

  12. Vascular endothelial growth factor-D over-expressing tumor cells induce differential effects on uterine vasculature in a mouse model of endometrial cancer

    Directory of Open Access Journals (Sweden)

    Stacker Steven A

    2010-07-01

    Full Text Available Abstract Background It has been hypothesised that increased VEGF-D expression may be an independent prognostic factor for endometrial cancer progression and lymph node metastasis; however, the mechanism by which VEGF-D may promote disease progression in women with endometrial cancer has not been investigated. Our aim was to describe the distribution of lymphatic vessels in mouse uterus and to examine the effect of VEGF-D over-expression on these vessels in a model of endometrial cancer. We hypothesised that VEGF-D over-expression would stimulate growth of new lymphatic vessels into the endometrium, thereby contributing to cancer progression. Methods We initially described the distribution of lymphatic vessels (Lyve-1, podoplanin, VEGFR-3 and VEGF-D expression in the mouse uterus during the estrous cycle, early pregnancy and in response to estradiol-17beta and progesterone using immunohistochemistry. We also examined the effects of VEGF-D over-expression on uterine vasculature by inoculating uterine horns in NOD SCID mice with control or VEGF-D-expressing 293EBNA tumor cells. Results Lymphatic vessels positive for the lymphatic endothelial cell markers Lyve-1, podoplanin and VEGFR-3 profiles were largely restricted to the connective tissue between the myometrial circular and longitudinal muscle layers; very few lymphatic vessel profiles were observed in the endometrium. VEGF-D immunostaining was present in all uterine compartments (epithelium, stroma, myometrium, although expression was generally low. VEGF-D immunoexpression was slightly but significantly higher in estrus relative to diestrus; and in estradiol-17beta treated mice relative to vehicle or progesterone treated mice. The presence of VEGF-D over-expressing tumor cells did not induce endometrial lymphangiogenesis, although changes were observed in existing vessel profiles. For myometrial lymphatic and endometrial blood vessels, the percentage of profiles containing proliferating

  13. Corneal collagen crosslinking for keratoconus. A review

    Directory of Open Access Journals (Sweden)

    M. M. Bikbov

    2014-10-01

    Full Text Available Photochemical crosslinking is widely applied in ophthalmology. Its biochemical effect is due to the release of singlet oxygen that promotes anaerobic photochemical reaction. Keratoconus is one of the most common corneal ectasia affecting 1 in 250 to 250 000 persons. Currently, the rate of iatrogenic ectasia following eximer laser refractive surgery increases due to biomechanical weakening of the cornea. Morphologically and biochemically, ectasia is characterized by corneal layers thinning, contact between the stroma and epithelium resulting from Bowman’s membrane rupture, chromatin fragmentation in keratocyte nuclei, phagocytosis, abnormal staining and arrangement of collagen fibers, enzyme system disorders, and keratocyte apoptosis. In corneal ectasia, altered enzymatic processes result in the synthesis of abnormal collagen. Collagen packing is determined by the activity of various extracellular matrix enzymes which bind amines and aldehydes of collagen fiber amino acids. In the late stage, morphological changes of Descemet’s membrane (i.e., rupture and detachment develop. Abnormal hexagonal-shaped keratocytes and their apoptosis are the signs of endothelial dystrophy. The lack of analogs in domestic ophthalmology encouraged the scientists of Ufa Eye Research Institute to develop a device for corneal collagen crosslinking. The parameters of ultraviolet (i.e., wavelength, exposure time, power to achieve the desired effect were identified. The specifics of some photosensitizers in the course of the procedure were studied. UFalink, a device for UV irradiation of cornea, and photosensitizer Dextralink were developed and adopted. Due to the high risk of endothelial damage, this treatment is contraindicated in severe keratoconus (CCT less than 400 microns. Major effects of corneal collagen crosslinking are the following: Young’s modulus (modulus of elasticity increase by 328.9 % (on average, temperature tolerance increase by 5

  14. Magnetic Resonance Tracking of Endothelial Progenitor Cells Labeled with Alkyl-Polyethylenimine 2 kDa/Superparamagnetic Iron Oxide in a Mouse Lung Carcinoma Xenograft Model

    Directory of Open Access Journals (Sweden)

    Cong Chen

    2014-11-01

    Full Text Available The potential of using endothelial progenitor cells (EPCs in novel anticancer therapy and the repair of vascular injury has been increasingly recognized. In the present study, EPCs were labeled with N-alkyl-polyethylenimine 2 kDa (PEI2k-stabilized superparamagnetic iron oxide (SPIO to facilitate magnetic resonance imaging (MRI of EPCs in a mouse lung carcinoma xenograft model. EPCs derived from human peripheral blood were labeled with alkyl-PEI2k/SPIO. The viability and activity of labeled cells were evaluated using proliferation, migration, and tubulogenesis assays. Alkyl-PEI2k/SPIO-labeled EPCs were injected intravenously (group 1 or mixed and injected together with A549 cells subcutaneously (group 2 into groups of six mice with severe combined immunodeficiency. The labeling efficiency with alkyl-PEI2k/SPIO at 7 mg Fe/mL concentration was approximately 100%. Quantitative analysis of cellular iron was 6.062 ± 0.050 pg/cell. No significant effects on EPC proliferation, migration, or tubulogenesis were seen after labeling. Seventesla micro-MRI showed the presence of schistic or linear hypointense regions at the tumor margins starting from days 7 to 8 after EPC administration. This gradually extended into the inner tumor layers in group 1. In group 2, tumor growth was accompanied by dispersion of low-signal intensity regions inside the tumor. Iron-positive cells identified by Prussian blue dye were seen at the sites identified using MRI. Human CD31-positive cells and mouse CD31-positive cells were present in both groups. Labeling EPCs with alkyl-PEI2k/SPIO allows noninvasive magnetic resonance investigation of EPC involvement in tumor neovasculature and is associated with excellent biocompatibility and MRI sensitivity.

  15. Thick keratoconic cornea associated with posterior polymorphous corneal dystrophy.

    Science.gov (United States)

    Zaarour, K; Slim, E; Antoun, J; Waked, N

    2017-03-01

    We herein report a case of bilateral unusually thick non-edematous keratoconic corneas with associated endothelial features of posterior polymorphous corneal dystrophy (PPCD). We report the case of a 27-year-old myopic woman who presented for refractive surgery. Slit lamp exam showed bilateral corneal protrusion with diffuse deep stromal and endothelial vesicular opacities and small paracentral bands. Topography showed generalized advanced corneal steepening in both eyes with increased anterior and posterior central corneal elevations in comparison to the best fit sphere. Ultrasound pachymetry showed central corneal thickness of 605μm (RE) and 612μm (LE). On specular biomicroscopy, cell density of 2503 cells/mm 2 RE and 1526 cells/mm 2 LE with significant cellular pleomorphism and polymegathism were noted. Clinical and paraclinical findings together suggest the presence of simultaneous keratoconus and PPCD. The literature has suggested an association between PPCD and steep cornea. Moreover, many reports have also described cases of associated PPCD and keratoconus with characteristic thinning and ectasia, in comparison to the unusual thick corneas noted in our patient, despite the absence of edema. Identification of genetics factors is further needed to clarify this association. This case describes a patient whose corneas present features of both keratoconus and PPCD and is unique due to the presence of increased corneal thickness despite the absence of edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Glaucoma after corneal replacement.

    Science.gov (United States)

    Baltaziak, Monika; Chew, Hall F; Podbielski, Dominik W; Ahmed, Iqbal Ike K

    Glaucoma is a well-known complication after corneal transplantation surgery. Traditional corneal transplantation surgery, specifically penetrating keratoplasty, has been slowly replaced by the advent of new corneal transplantation procedures: primarily lamellar keratoplasties. There has also been an emergence of keratoprosthesis implants for eyes that are high risk of failure with penetrating keratoplasty. Consequently, there are different rates of glaucoma, pathogenesis, and potential treatment in the form of medical, laser, or surgical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Crystalline Subtype of Pre-Descemetic Corneal Dystrophy

    Directory of Open Access Journals (Sweden)

    Rosa Dolz-Marco

    2014-01-01

    Full Text Available Purpose: To report corneal findings in a familial case of the crystalline subtype of pre- Descemetic corneal dystrophy. Case Report: A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion: To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder corneal dystrophy, cystinosis, Bietti΄s dystrophy and monoclonal gammopathy.

  18. Crystalline Subtype of Pre-Descemetic Corneal Dystrophy

    Science.gov (United States)

    Dolz-Marco, Rosa; Gallego-Pinazo, Roberto; Pinazo-Durán, María Dolores; Díaz-Llopis, Manuel

    2014-01-01

    Purpose To report corneal findings in a familial case of the crystalline subtype of pre-Descemetic corneal dystrophy. Case Report A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder corneal dystrophy, cystinosis, Bietti´s dystrophy and monoclonal gammopathy. PMID:25279130

  19. Evaluation of Topical Cyclosporine in Preventing the Development of Corneal Haze after Photorefractive Keratectomy

    Science.gov (United States)

    2014-05-13

    NAME OF RESPONSIBLE PERSON: a. REPORT UNCLASSIFIED b. ABSTRACT UNCLASSIFIED c. THIS PAGE UNCLASSIFIED 19b. TELEPHONE NUMBER...fibroblast proliferation and concomitant fibrotic scar deposition at the corneal wound site. Unfortunately, mitomycin C also inhibits epithelial...stromal, and endothelial replication and can lead to vascular endothelial injury and secondary tissue necrosis. 3 Due to these side effects, steroids are

  20. An ?All-laser? Endothelial Transplant

    OpenAIRE

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-01-01

    The ?all laser? assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in...

  1. Using corneal confocal microscopy to track changes in the corneal layers of dry eye patients after autologous serum treatment.

    Science.gov (United States)

    Mahelkova, Gabriela; Jirsova, Katerina; Seidler Stangova, Petra; Palos, Michalis; Vesela, Viera; Fales, Ivan; Jiraskova, Nada; Dotrelova, Dagmar

    2017-05-01

    In vivo corneal confocal microscopy allows the examination of each layer of the cornea in detail and the identification of pathological changes at the cellular level. The purpose of this study was to identify the possible effects of a three-month treatment with autologous serum eye-drops in different corneal layers of patients with severe dry eye disease using corneal confocal microscopy. Twenty-six patients with dry eye disease were included in the study. Corneal fluorescein staining was performed. The corneas of the right eyes were examined using in vivo corneal confocal microscopy before and after a three-month treatment with autologous serum drops. The densities of superficial and basal epithelial cells, Langerhans cells, the keratocytes and activated keratocytes, the density of endothelial cells and the status of the sub-basal nerve plexus fibres were evaluated. A significant decrease in corneal fluorescein staining was found after the three-month autologous serum treatment (p = 0.0006). The basal epithelial cell density decreased significantly (p = 0.001), while the density of superficial epithelial cells did not change significantly (p = 0.473) nor did the number of Langerhans cells or activated keratocytes (p = 0.223; p = 0.307, respectively). There were no differences in the other corneal cell layers or in the status of the nerve fibres. The results demonstrate the ability of corneal confocal microscopy to evaluate an improvement in the basal epithelial cell layer of the cornea after autologous serum treatment in patients with dry eye disease. More studies with longer follow-up periods are needed to elucidate the suitability of corneal confocal microscopy to follow the effect of autologous serum treatment on nerve fibres or other corneal layers in dry eye disease patients. © 2016 Optometry Australia.

  2. Explore the full thick layer of corneal transplantation in the treatment of pseudomonas aeruginosa corneal ulcer infection

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2015-02-01

    Full Text Available AIM: To explore the feasibility, safety and effect of the full-thickness lamellar keratoplasty for the treatment of pseudomonas aeruginosa corneal ulcer. METHODS: Based on a retrospective non-controlled study, 25 patients were given the full-thickness lamellar keratoplasty for clinical diagnosis of pseudomonas aeruginosa infection and corneal ulcer medication conventional anti-gram-negative bacteria. Routine follow-up were carried out at postoperative 1wk; 1, 3, 6, 12, 18mo to observe the situation of corneal epithelial healing, recurrent infection, immune rejection, graft transparency and best corrected visual acuity, etc. At the 6 and 12mo postoperative, corneal endothelial cell density was reexamined.RESULTS: No patients because of Descemet's membrane rupture underwent penetrating keratoplasty surgery: One only in cases of bacterial infection after 1mo, once again did not cultivate a culture of bacteria pseudomonas aeruginosa, and the remaining 24 cases average follow-up 14±6mo, corneal graft were transparent, the cure rate was 96%. At the sixth month after surgery, there were 16 cases of eye surgery best corrected visual acuity ≥4.5, of which 3 cases ≥4.8. At the sixth month after surgery, the average corneal endothelial cell density 2 425±278/mm2; At 12mo postoperatively, it was 2 257± 326/mm2.CONCLUSION: Full-thickness lamellar keratoplasty is an effective method of pseudomonas aeruginosa infection in the treatment of corneal ulcers, corneal drying material glycerol can be achieved by visual effects.

  3. Ketamine alleviates bradykinin-induced disruption of the mouse cerebrovascular endothelial cell-constructed tight junction barrier via a calcium-mediated redistribution of occludin polymerization

    International Nuclear Information System (INIS)

    Chen, Jui-Tai; Lin, Yi-Ling; Chen, Ta-Liang; Tai, Yu-Ting; Chen, Cheng-Yu; Chen, Ruei-Ming

    2016-01-01

    Highlights: • Ketamine could suppress bradykinin-induced intracellular calcium mobilization. • Ketamine induced B1R protein and mRNA expressions but did not change B2R protein levels. • Ketamine attenuated bradykinin-induced redistribution of occludin tight junctions. • Ketamine prevented bradykinin-induced breakage of the MCEC-constructed tight junction barrier. - Abstract: Following brain injury, a sequence of mechanisms leads to disruption of the blood-brain barrier (BBB) and subsequent cerebral edema, which is thought to begin with activation of bradykinin. Our previous studies showed that ketamine, a widely used intravenous anesthetic agent, can suppress bradykinin-induced cell dysfunction. This study further aimed to evaluate the protective effects of ketamine against bradykinin-induced disruption of the mouse cerebrovascular endothelial cell (MCEC)-constructed tight junction barrier and the possible mechanisms. Exposure of MCECs to bradykinin increased intracellular calcium (Ca 2+ ) concentrations in a time-dependent manner. However, pretreatment of MCECs with ketamine time- and concentration-dependently lowered the bradykinin-induced calcium influx. As to the mechanisms, although exposure of MCECs to ketamine induced bradykinin R1 receptor protein and mRNA expression, this anesthetic did not change levels of the bradykinin R2 receptor, a major receptor that responds to bradykinin stimulation. Bradykinin increased amounts of soluble occludin in MCECs, but pretreatment with ketamine alleviated this disturbance in occludin polymerization. Consequently, exposure to bradykinin decreased the transendothelial electronic resistance in the MCEC-constructed tight junction barrier. However, pretreatment with ketamine attenuated the bradykinin-induced disruption of the tight junction barrier. Taken together, this study shows that ketamine at a therapeutic concentration can protect against bradykinin-induced breakage of the BBB via suppressing calcium

  4. Fibroblast growth factor-2-induced host stroma reaction during initial tumor growth promotes progression of mouse melanoma via vascular endothelial growth factor A-dependent neovascularization.

    Science.gov (United States)

    Tsunoda, Satoshi; Nakamura, Toshiyuki; Sakurai, Hiroaki; Saiki, Ikuo

    2007-04-01

    Fibroblast growth factor (FGF)-2 has been considered to play a critical role in neovascularization in several tumors; however, its precise role in tumor progression is not fully understood. In the present study, we have characterized the role of FGF-2 in B16-BL6 mouse melanoma cells, focusing on effects during the initial phase of tumor growth. FGF-2 was injected at the tumor inoculation site of dorsal skin during the initial phase. FGF-2 induced marked tumor growth and lymph node metastasis. This was well correlated with an increase in neovascularization in the host stroma. FGF-2 also recruited inflammatory and mesenchymal cells in host stroma. Marked tumor growth, pulmonary metastasis and intensive neovascularization in tumor parenchyma were also observed after a single injection of FGF-2 into the footpad inoculation site. In contrast, repeated injections of FGF-2 at a site remote from the footpad tumor were ineffective in promoting tumor growth and metastasis. These promoting activities of FGF-2 were blocked by local injections of a glucocorticoid hormone, suggesting that host inflammatory responses induced by FGF-2 are associated with FGF-2-induced tumor progression. In addition, although FGF-2 did not promote cellular proliferation and vascular endothelial growth factor A (VEGFA) mRNA expression in B16-BL6 cells in vitro, FGF-2 induced VEGFA expression in host stroma rather than tumor tissue, and local injections of a neutralizing antibody against VEGFA inhibited these activities of FGF-2 in vivo. These results indicate that abundant FGF-2 during the initial phase of tumor growth induces VEGFA-dependent intensive neovascularization in host stroma, and supports marked tumor growth and metastasis.

  5. Culture media-based selection of endothelial cells, pericytes, and perivascular-resident macrophage-like melanocytes from the young mouse vestibular system.

    Science.gov (United States)

    Zhang, Jinhui; Chen, Songlin; Cai, Jing; Hou, Zhiqiang; Wang, Xiaohan; Kachelmeier, Allan; Shi, Xiaorui

    2017-03-01

    The vestibular blood-labyrinth barrier (BLB) is comprised of perivascular-resident macrophage-like melanocytes (PVM/Ms) and pericytes (PCs), in addition to endothelial cells (ECs) and basement membrane (BM), and bears strong resemblance to the cochlear BLB in the stria vascularis. Over the past few decades, in vitro cell-based models have been widely used in blood-brain barrier (BBB) and blood-retina barrier (BRB) research, and have proved to be powerful tools for studying cell-cell interactions in their respective organs. Study of both the vestibular and strial BLB has been limited by the unavailability of primary culture cells from these barriers. To better understand how barrier component cells interact in the vestibular system to control BLB function, we developed a novel culture medium-based method for obtaining EC, PC, and PVM/M primary cells from tiny explants of the semicircular canal, sacculus, utriculus, and ampullae tissue of young mouse ears at post-natal age 8-12 d. Each phenotype is grown in a specific culture medium which selectively supports the phenotype in a mixed population of vestibular cell types. The unwanted phenotypes do not survive passaging. The protocol does not require additional equipment or special enzyme treatment. The harvesting process takes less than 2 h. Primary cell types are generated within 7-10 d. The primary culture ECs, PCs, and PVM/M shave consistent phenotypes more than 90% pure after two passages (∼ 3 weeks). The highly purified primary cell lines can be used for studying cell-cell interactions, barrier permeability, and angiogenesis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Indications for Corneal Transplantation at a Tertiary Referral Center in Tehran

    Directory of Open Access Journals (Sweden)

    Mohammad Zare

    2010-01-01

    Full Text Available Purpose: To report the indications and techniques of corneal transplantation at a tertiary referral center in Tehran over a 3-year period. Methods: Records of patients who had undergone any kind of corneal transplantation at Labbafinejad Medical Center, Tehran, Iran from March 2004 to March 2007 were reviewed to determine the indications and types of corneal transplantation. Results: During this period, 776 eyes of 756 patients (including 504 male subjects with mean age of 41.3±21.3 years underwent corneal transplantation. The most common indication was keratoconus (n=317, 40.8% followed by bullous keratopathy (n=90, 11.6%, non-herpetic corneal scars (n=62, 8.0%, infectious corneal ulcers (n=61, 7.9%, previously failed grafts (n=61, 7.9%, endothelial and stromal corneal dystrophies (n=28, 3.6%, and trachoma keratopathy (n=26, 3.3%. Other indications including Terrien′s marginal degeneration, post-LASIK keratectasia, trauma, chemical burns, and peripheral ulcerative keratitis constituted the rest of cases. Techniques of corneal transplantation included penetrating keratoplasty (n=607, 78.2%, deep anterior lamellar keratoplasty (n=108, 13.9%, conventional lamellar keratoplasty (n=44, 5.7%, automated lamellar therapeutic keratoplasty (n=8, 1.0%, and Descemet stripping endothelial keratoplasty (n=6, 0.8% in descending order. The remaining cases were endothelial keratoplasty and sclerokeratoplasty. Conclusion: In this study, keratoconus was the most common indication for penetrating keratoplasty which was the most prevalent technique of corneal transplantation. However, deep anterior lamellar keratoplasty is emerging as a growing alternative for corneal pathologies not involving the endothelium.

  7. Human corneal epithelial subpopulations

    DEFF Research Database (Denmark)

    Søndergaard, Chris Bath

    2013-01-01

    Corneal epithelium is being regenerated throughout life by limbal epithelial stem cells (LESCs) believed to be located in histologically defined stem cell niches in corneal limbus. Defective or dysfunctional LESCs result in limbal stem cell deficiency (LSCD) causing pain and decreased visual acuity...... subpopulations in human corneal epithelium using a combination of laser capture microdissection and RNA sequencing for global transcriptomic profiling. We compared dissociation cultures, using either expansion on γ-irradiated NIH/3T3 feeder cells in serum-rich medium or expansion directly on plastic in serum...

  8. Corneal Allograft Rejection: Topical Treatment Vs. Pulsed Intravenous Methylprednisolone - Ten Years' Result [rejeição De Transplantes De Córnea: Tratamento Tópico Vs. Pulsoterapia - Resultados De 10 Anos

    OpenAIRE

    Costa D.C.; de Castro R.S.; Ferraz de Camargo M.S.; Kara-Jose N.

    2008-01-01

    Purpose: To evaluate the efficacy of intravenous 500 mg methylprednisolone in addition to topical treatment with 1% prednisolone in the treatment of the first episode of corneal endothelial rejection in patients that were submitted to corneal allograft transplantation. Methods: Retrospective casecontrol study with 81 patients that presented the first episode of corneal endothelial rejection and were treated within the first 15 days of the onset of symptoms. Results: 67 patients were treated w...

  9. Descemet Stripping Automated Endothelial Keratoplasty for Endothelial Dysfunction in Xeroderma Pigmentosum: A Clinicopathological Correlation and Review of Literature.

    Science.gov (United States)

    Vira, Divya; Fernandes, Merle; Mittal, Ruchi

    2016-07-01

    Xeroderma pigmentosum (XP) mainly affects the ocular surface; however, endothelial damage may also occur. We would like to report changes in the endothelial-Descemet layer and review the literature on similar findings in patients with XP, including the role of Descemet stripping automated endothelial keratoplasty (DSAEK) in the management of a 21-year-old man who presented with nonresolving corneal edema in the right eye after excision biopsy for conjunctival intraepithelial neoplasia. His best-corrected visual acuity (BCVA) was 20/200 in the right eye and 20/20 in the left eye. On general examination, there was patchy hyperpigmentation of the exposed areas of skin suggestive of XP. On examination of the right eye, there was stromal edema involving the exposed half of cornea. The left eye appeared normal. Pachymetry readings were 860 and 600 μm in the right and left eye, respectively. Descemet stripping automated endothelial keratoplasty was performed for endothelial dysfunction and the stripped endothelium, and Descemet membrane (DM) was sent for histopathologic evaluation. Postoperatively, the donor lenticule was well apposed and the overlying stromal edema resolved. The patient achieved a BCVA of 20/30 in the right eye without progression of corneal scarring at 1-year follow-up. In the meanwhile, however, the left eye developed corneal edema. Histopathology revealed gross attenuation of endothelial cells with uniform thickness of the DM. Corneal endothelial dysfunction in XP is amenable to treatment with DSAEK.

  10. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

    Directory of Open Access Journals (Sweden)

    Tojo N

    2015-03-01

    Full Text Available Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS.Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea 

  11. Diagnosis and Management of Iridocorneal Endothelial Syndrome

    Science.gov (United States)

    Sacchetti, Marta; Mantelli, Flavio; Macchi, Ilaria; Ambrosio, Oriella; Rama, Paolo

    2015-01-01

    The iridocorneal endothelial (ICE) syndrome is a rare ocular disorder that includes a group of conditions characterized by structural and proliferative abnormalities of the corneal endothelium, the anterior chamber angle, and the iris. Common clinical features include corneal edema, secondary glaucoma, iris atrophy, and pupillary anomalies, ranging from distortion to polycoria. The main subtypes of this syndrome are the progressive iris atrophy, the Cogan-Reese syndrome, and the Chandler syndrome. ICE syndrome is usually diagnosed in women in the adult age. Clinical history and complete eye examination including tonometry and gonioscopy are necessary to reach a diagnosis. Imaging techniques, such as in vivo confocal microscopy and ultrasound biomicroscopy, are used to confirm the diagnosis by revealing the presence of “ICE-cells” on the corneal endothelium and the structural changes of the anterior chamber angle. An early diagnosis is helpful to better manage the most challenging complications such as secondary glaucoma and corneal edema. Treatment of ICE-related glaucoma often requires glaucoma filtering surgery with antifibrotic agents and the use of glaucoma drainage implants should be considered early in the management of these patients. Visual impairment and pain associated with corneal edema can be successfully managed with endothelial keratoplasty. PMID:26451377

  12. Morphology of endothelial cells from different regions of the equine cornea

    OpenAIRE

    Faganello, Cláudia Skilhan; Silva, Vanessa Ruiz Moura da; Andrade, Maria Cristina Caldart de; Carissimi, André Silva; Pigatto, João Antonio Tadeu

    2016-01-01

    ABSTRACT: The objective of this study was to evaluate the morphology of different regions of the equine cornea using optical microscopy. Both healthy eyes of eight horses, male or female, of different ages were evaluated. Corneas were stained with alizarin red vital dye and subsequently examined and photographed using optical microscopy. Corneal endothelial morphology of central, superior, inferior, temporal and nasal areas was assessed. One hundred endothelial cells from each corneal area we...

  13. The Favorable Effect of Mesenchymal Stem Cell Treatment on the Antioxidant Protective Mechanism in the Corneal Epithelium and Renewal of Corneal Optical Properties Changed after Alkali Burns

    Science.gov (United States)

    Cejka, Cestmir; Holan, Vladimir; Trosan, Peter; Zajicova, Alena; Javorkova, Eliska; Cejkova, Jitka

    2016-01-01

    The aim of this study was to examine whether mesenchymal stem cells (MSCs) and/or corneal limbal epithelial stem cells (LSCs) influence restoration of an antioxidant protective mechanism in the corneal epithelium and renewal of corneal optical properties changed after alkali burns. The injured rabbit corneas (with 0.25 N NaOH) were untreated or treated with nanofiber scaffolds free of stem cells, with nanofiber scaffolds seeded with bone marrow MSCs (BM-MSCs), with adipose tissue MSCs (Ad-MSCs), or with LSCs. On day 15 following the injury, after BM-MSCs or LSCs nanofiber treatment (less after Ad-MSCs treatment) the expression of antioxidant enzymes was restored in the regenerated corneal epithelium and the expressions of matrix metalloproteinase 9 (MMP9), inducible nitric oxide synthase (iNOS), α-smooth muscle actin (α-SMA), transforming growth factor-β1 (TGF-β1), and vascular endothelial factor (VEGF) were low. The central corneal thickness (taken as an index of corneal hydration) increased after the injury and returned to levels before the injury. In injured untreated corneas the epithelium was absent and numerous cells revealed the expressions of iNOS, MMP9, α-SMA, TGF-β1, and VEGF. In conclusion, stem cell treatment accelerated regeneration of the corneal epithelium, restored the antioxidant protective mechanism, and renewed corneal optical properties. PMID:27057279

  14. The Favorable Effect of Mesenchymal Stem Cell Treatment on the Antioxidant Protective Mechanism in the Corneal Epithelium and Renewal of Corneal Optical Properties Changed after Alkali Burns.

    Science.gov (United States)

    Cejka, Cestmir; Holan, Vladimir; Trosan, Peter; Zajicova, Alena; Javorkova, Eliska; Cejkova, Jitka

    2016-01-01

    The aim of this study was to examine whether mesenchymal stem cells (MSCs) and/or corneal limbal epithelial stem cells (LSCs) influence restoration of an antioxidant protective mechanism in the corneal epithelium and renewal of corneal optical properties changed after alkali burns. The injured rabbit corneas (with 0.25 N NaOH) were untreated or treated with nanofiber scaffolds free of stem cells, with nanofiber scaffolds seeded with bone marrow MSCs (BM-MSCs), with adipose tissue MSCs (Ad-MSCs), or with LSCs. On day 15 following the injury, after BM-MSCs or LSCs nanofiber treatment (less after Ad-MSCs treatment) the expression of antioxidant enzymes was restored in the regenerated corneal epithelium and the expressions of matrix metalloproteinase 9 (MMP9), inducible nitric oxide synthase (iNOS), α-smooth muscle actin (α-SMA), transforming growth factor-β1 (TGF-β1), and vascular endothelial factor (VEGF) were low. The central corneal thickness (taken as an index of corneal hydration) increased after the injury and returned to levels before the injury. In injured untreated corneas the epithelium was absent and numerous cells revealed the expressions of iNOS, MMP9, α-SMA, TGF-β1, and VEGF. In conclusion, stem cell treatment accelerated regeneration of the corneal epithelium, restored the antioxidant protective mechanism, and renewed corneal optical properties.

  15. The Favorable Effect of Mesenchymal Stem Cell Treatment on the Antioxidant Protective Mechanism in the Corneal Epithelium and Renewal of Corneal Optical Properties Changed after Alkali Burns

    Directory of Open Access Journals (Sweden)

    Cestmir Cejka

    2016-01-01

    Full Text Available The aim of this study was to examine whether mesenchymal stem cells (MSCs and/or corneal limbal epithelial stem cells (LSCs influence restoration of an antioxidant protective mechanism in the corneal epithelium and renewal of corneal optical properties changed after alkali burns. The injured rabbit corneas (with 0.25 N NaOH were untreated or treated with nanofiber scaffolds free of stem cells, with nanofiber scaffolds seeded with bone marrow MSCs (BM-MSCs, with adipose tissue MSCs (Ad-MSCs, or with LSCs. On day 15 following the injury, after BM-MSCs or LSCs nanofiber treatment (less after Ad-MSCs treatment the expression of antioxidant enzymes was restored in the regenerated corneal epithelium and the expressions of matrix metalloproteinase 9 (MMP9, inducible nitric oxide synthase (iNOS, α-smooth muscle actin (α-SMA, transforming growth factor-β1 (TGF-β1, and vascular endothelial factor (VEGF were low. The central corneal thickness (taken as an index of corneal hydration increased after the injury and returned to levels before the injury. In injured untreated corneas the epithelium was absent and numerous cells revealed the expressions of iNOS, MMP9, α-SMA, TGF-β1, and VEGF. In conclusion, stem cell treatment accelerated regeneration of the corneal epithelium, restored the antioxidant protective mechanism, and renewed corneal optical properties.

  16. Confocal microscopy and electrophysiological study of single patient corneal endothelium cell cultures

    Science.gov (United States)

    Tatini, Francesca; Rossi, Francesca; Coppi, Elisabetta; Magni, Giada; Fusco, Irene; Menabuoni, Luca; Pedata, Felicita; Pugliese, Anna Maria; Pini, Roberto

    2016-04-01

    The characterization of the ion channels in corneal endothelial cells and the elucidation of their involvement in corneal pathologies would lead to the identification of new molecular target for pharmacological treatments and to the clarification of corneal physiology. The corneal endothelium is an amitotic cell monolayer with a major role in preserving corneal transparency and in regulating the water and solute flux across the posterior surface of the cornea. Although endothelial cells are non-excitable, they express a range of ion channels, such as voltage-dependent Na+ channels and K+ channels, L-type Ca2 channels and many others. Interestingly, purinergic receptors have been linked to a variety of conditions within the eye but their presence in the endothelium and their role in its pathophysiology is still uncertain. In this study, we were able to extract endothelial cells from single human corneas, thus obtaining primary cultures that represent the peculiarity of each donor. Corneas were from tissues not suitable for transplant in patients. We characterized the endothelial cells by confocal microscopy, both within the intact cornea and in the primary endothelial cells cultures. We also studied the functional role of the purinergic system (adenosine, ATP and their receptors) by means of electrophysiological recordings. The experiments were performed by patch clamp recordings and confocal time-lapse microscopy and our results indicate that the application of purinergic compounds modulates the amplitude of outward currents in the isolated endothelial cells. These findings may lead to the proposal of new therapies for endothelium-related corneal diseases.

  17. Distrofia corneal de Schnyder

    Directory of Open Access Journals (Sweden)

    Michel Guerra Almaguer

    Full Text Available La principal entidad hereditaria con depósitos de lípidos en el estroma corneal es la distrofia cristalina central, conocida como distrofia de Schnyder, quien la describió en Suiza en 1927. Se caracteriza por depósitos blanco-amarillentos en el estroma corneal central y superficial. Se presenta un paciente de 28 años, del sexo masculino y piel negra, con antecedente de salud anterior. Acudió a consulta y refirió una disminución de la visión y cambio de coloración progresiva de ambos ojos, de años de evolución. En la exploración oftalmológica de ambos ojos se apreciaron lesiones blanquecinas anulares a nivel del estroma corneal, con ligera turbidez corneal central. Los estudios refractivos realizados constataron un astigmatismo hipermetrópico simple. El resto del examen oftalmológico fue negativo. Para el diagnóstico de certeza se empleó el microscopio confocal. Se concluye que el caso presenta una distrofia corneal estromal de tipo cristalina, de Schnyder.

  18. Inhibition of corneal neovascularization by recombinant adenovirus-mediated sFlk-1 expression

    International Nuclear Information System (INIS)

    Yu Hui; Wu Jihong; Li Huiming; Wang Zhanli; Chen Xiafang; Tian Yuhua; Yi Miaoying; Ji Xunda; Ma Jialie; Huang Qian

    2007-01-01

    The interaction of vascular endothelial growth factor (VEGF) and its receptors (Flt-1, Flk-1/KDR) is correlated with neovascularization in the eyes. Therefore, blocking the binding of VEGF and the corresponding receptor has become critical for inhibiting corneal neovascularization. In this study, we have expressed the cDNA for sFlk-1 under the control of cytomegalovirus immediate-early promoter (CMV) from an E1/partial E3 deleted replication defective recombinant adenovirus, and Ad.sflk-1 expression was determined by Western blotting. We have shown that conditioned media from Ad.sflk-1-infected ARPE-19 cells significantly reduced VEGF-induced human umbilical vein endothelial cells (HUVEC) and murine endothelial cells (SVEC) proliferation in vitro compared with the control vector. In vivo, adenoviral vectors expressing green fluorescent protein alone (Ad.GFP) were utilized to monitor gene transfer to the cornea. Moreover, in the models of corneal neovascularization, the injection of Ad.sflk-1 (10 8 PFU) into the anterior chamber could significantly inhibit angiogenic changes compared with Ad.null-injected and vehicle-injected models. Immunohistochemical analysis showed that corneal endothelial cells and corneal stroma of cauterized rat eyes were efficiently transduced and expressed sFlk-1. These results not only support that adenoviral vectors are capable of high-level transgene expression but also demonstrate that Ad.sflk-1 gene therapy might be a feasible approach for inhibiting the development of corneal neovascularization

  19. Corneal Graft Rejection: Incidence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafii

    2008-12-01

    Full Text Available

    PURPOSE: To determine the incidence and risk factors of late corneal graft rejection after penetrating keratoplasty (PKP. METHODS: Records of all patients who had undergone PKP from 2002 to 2004 without immunosuppressive therapy other than systemic steroids and with at least one year of follow up were reviewed. The role of possible risk factors such as demographic factors, other host factors, donor factors, indications for PKP as well as type of rejection were evaluated. RESULTS: During the study period, 295 PKPs were performed on 286 patients (176 male, 110 female. Mean age at the time of keratoplasty was 38±20 (range, 40 days to 90 years and mean follow up period was 20±10 (range 12-43 months. Graft rejection occurred in 94 eyes (31.8% at an average of 7.3±6 months (range, 20 days to 39 months after PKP. The most common type of rejection was endothelial (20.7%. Corneal vascularization, regrafting, anterior synechiae, irritating sutures, active inflammation, additional anterior segment procedures, history of trauma, uncontrolled glaucoma, prior graft rejection, recurrence of herpetic infection and eccentric grafting increased the rate of rejection. Patient age, donor size and bilateral transplantation had no significant influence on graft rejection. CONCLUSION: Significant risk factors for corneal graft rejection include

  20. Granular corneal dystrophy

    OpenAIRE

    Castillo Pérez, Alexeide de la C; Vilches Lescaille, Daysi; Noriega, Justo Luis; Martínez Balido, Daneel; León Balbón, Bárbaro Ramón; León Bernal, Danysleidi

    2015-01-01

    Las distrofias corneales constituyen un conjunto de enfermedades que presentan, en su mayoría, una baja incidencia y se caracterizan por acúmulo de material hialino o amiloide que disminuyen la transparencia corneal. La distrofia granular es una enfermedad autosómica dominante que presenta opacidades grises en el estroma superficial central de la córnea y se hacen visibles en la primera y segunda décadas de la vida, lo que provoca disminución de la visión más significativa cerca de los 40 año...

  1. Airbag induced corneal ectasia.

    Science.gov (United States)

    Mearza, Ali A; Koufaki, Fedra N; Aslanides, Ioannis M

    2008-02-01

    To report a case of airbag induced corneal ectasia. Case report. A patient 3 years post-LASIK developed bilateral corneal ectasia worse in the right eye following airbag deployment in a road traffic accident. At last follow up, best corrected vision was 20/40 with -4.00/-4.00 x 25 in the right eye and 20/25 with -1.25/-0.50 x 135 in the left eye. This is a rare presentation of trauma induced ectasia in a patient post-LASIK. It is possible that reduction in biomechanical integrity of the cornea from prior refractive surgery contributed to this presentation.

  2. Positive Feedback Regulation of Agonist-Stimulated Endothelial Ca2+ Dynamics by KCa3.1 Channels in Mouse Mesenteric Arteries

    DEFF Research Database (Denmark)

    Qian, Xun; Francis, Michael; Köhler, Ralf

    2014-01-01

    Intermediate and small conductance KCa channels IK1 (KCa3.1) and SK3 (KCa2.3) are primary targets of endothelial Ca(2+) signals in the arterial vasculature, and their ablation results in increased arterial tone and hypertension. Activation of IK1 channels by local Ca(2+) transients from internal ...... stores or plasma membrane channels promotes arterial hyperpolarization and vasodilation. Here, we assess arteries from genetically altered IK1 knockout mice (IK1(-/-)) to determine whether IK1 channels exert a positive feedback influence on endothelial Ca(2+) dynamics....

  3. Intracavernous Delivery of a Designed Angiopoietin-1 Variant Rescues Erectile Function by Enhancing Endothelial Regeneration in the Streptozotocin-Induced Diabetic Mouse

    Science.gov (United States)

    Jin, Hai-Rong; Kim, Woo Jean; Song, Jae Sook; Piao, Shuguang; Choi, Min Ji; Tumurbaatar, Munkhbayar; Shin, Sun Hwa; Yin, Guo Nan; Koh, Gou Young; Ryu, Ji-Kan; Suh, Jun-Kyu

    2011-01-01

    OBJECTIVE Patients with diabetic erectile dysfunction often have severe endothelial dysfunction and respond poorly to oral phosphodiesterase-5 inhibitors. We examined the effectiveness of the potent angiopoietin-1 (Ang1) variant, cartilage oligomeric matrix protein (COMP)-Ang1, in promoting cavernous endothelial regeneration and restoring erectile function in diabetic animals. RESEARCH DESIGN AND METHODS Four groups of mice were used: controls; streptozotocin (STZ)-induced diabetic mice; STZ-induced diabetic mice treated with repeated intracavernous injections of PBS; and STZ-induced diabetic mice treated with COMP-Ang1 protein (days −3 and 0). Two and 4 weeks after treatment, we measured erectile function by electrical stimulation of the cavernous nerve. The penis was harvested for histologic examinations, Western blot analysis, and cGMP quantification. We also performed a vascular permeability test. RESULTS Local delivery of the COMP-Ang1 protein significantly increased cavernous endothelial proliferation, endothelial nitric oxide (NO) synthase (NOS) phosphorylation, and cGMP expression compared with that in the untreated or PBS-treated STZ-induced diabetic group. The changes in the group that received COMP-Ang1 restored erectile function up to 4 weeks after treatment. Endothelial protective effects, such as marked decreases in the expression of p47phox and inducible NOS, in the generation of superoxide anion and nitrotyrosine, and in the number of apoptotic cells in the corpus cavernosum tissue, were noted in COMP-Ang1–treated STZ-induced diabetic mice. An intracavernous injection of COMP-Ang1 completely restored endothelial cell-cell junction proteins and decreased cavernous endothelial permeability. COMP-Ang1–induced promotion of cavernous angiogenesis and erectile function was abolished by the NOS inhibitor, N-nitro-L-arginine methyl ester, but not by the NADPH oxidase inhibitor, apocynin. CONCLUSIONS These findings support the concept of cavernous

  4. Signaling hierarchy regulating human endothelial cell development

    Science.gov (United States)

    Our present knowledge of the regulation of mammalian endothelial cell differentiation has been largely derived from studies of mouse embryonic development. However, unique mechanisms and hierarchy of signals that govern human endothelial cell development are unknown and, thus, explored in these stud...

  5. Topical administration of orbital fat-derived stem cells promotes corneal tissue regeneration.

    Science.gov (United States)

    Lin, Ko-Jo; Loi, Mei-Xue; Lien, Gi-Shih; Cheng, Chieh-Feng; Pao, Hsiang-Yin; Chang, Yun-Chuang; Ji, Andrea Tung-Qian; Ho, Jennifer Hui-Chun

    2013-06-14

    Topical administration of eye drops is the major route for drug delivery to the cornea. Orbital fat-derived stem cells (OFSCs) possess an in vitro corneal epithelial differentiation capacity. Both the safety and immunomodulatory ability of systemic OFSC transplantation were demonstrated in our previous work. In this study, we investigated the safety, therapeutic effect, and mechanism(s) of topical OFSC administration in an extensive alkali-induced corneal wound. Corneal injury was created by contact of a piece of 0.5 N NaOH-containing filter paper on the corneal surface of a male Balb/c mouse for 30 s. The area of the filter paper covered the central 70% or 100% of the corneal surface. OFSCs (2 × 10(5)) in 5 μl phosphate-buffered saline (PBS) were given by topical administration (T) twice a day or by two intralimbal (IL) injections in the right cornea, while 5 μl of PBS in the left cornea served as the control. Topical OFSCs promoted corneal re-epithelialization of both the limbal-sparing and limbal-involved corneal wounds. In the first three days, topical OFSCs significantly reduced alkali-induced corneal edema and stromal infiltration according to a histopathological examination. Immunohistochemistry and immunofluorescence staining revealed that transplanted cells were easily detectable in the corneal epithelium, limbal epithelium and stroma, but only some of transplanted cells at the limbal epithelium had differentiated into cytokeratin 3-expressing cells. OFSCs did not alter neutrophil (Ly6G) levels in the cornea, but significantly reduced macrophage (CD68) infiltration and inducible nitrous oxide synthetase (iNOS) production during acute corneal injury as quantified by a Western blot analysis. Continuous topical administration of OFSCs for seven days improved corneal transparency, and this was accompanied by diffuse stromal engraftment of transplanted cells and differentiation into p63-expressing cells at the limbal area. The therapeutic effect of the

  6. Topical administration of orbital fat-derived stem cells promotes corneal tissue regeneration

    Science.gov (United States)

    2013-01-01

    Introduction Topical administration of eye drops is the major route for drug delivery to the cornea. Orbital fat-derived stem cells (OFSCs) possess an in vitro corneal epithelial differentiation capacity. Both the safety and immunomodulatory ability of systemic OFSC transplantation were demonstrated in our previous work. In this study, we investigated the safety, therapeutic effect, and mechanism(s) of topical OFSC administration in an extensive alkali-induced corneal wound. Methods Corneal injury was created by contact of a piece of 0.5 N NaOH-containing filter paper on the corneal surface of a male Balb/c mouse for 30 s. The area of the filter paper covered the central 70% or 100% of the corneal surface. OFSCs (2 × 105) in 5 μl phosphate-buffered saline (PBS) were given by topical administration (T) twice a day or by two intralimbal (IL) injections in the right cornea, while 5 μl of PBS in the left cornea served as the control. Results Topical OFSCs promoted corneal re-epithelialization of both the limbal-sparing and limbal-involved corneal wounds. In the first three days, topical OFSCs significantly reduced alkali-induced corneal edema and stromal infiltration according to a histopathological examination. Immunohistochemistry and immunofluorescence staining revealed that transplanted cells were easily detectable in the corneal epithelium, limbal epithelium and stroma, but only some of transplanted cells at the limbal epithelium had differentiated into cytokeratin 3-expressing cells. OFSCs did not alter neutrophil (Ly6G) levels in the cornea, but significantly reduced macrophage (CD68) infiltration and inducible nitrous oxide synthetase (iNOS) production during acute corneal injury as quantified by a Western blot analysis. Continuous topical administration of OFSCs for seven days improved corneal transparency, and this was accompanied by diffuse stromal engraftment of transplanted cells and differentiation into p63-expressing cells at the limbal area. The

  7. Bilateral lesions of suprachiasmatic nuclei affect circadian rhythms in [3H]-thymidine incorporation into deoxyribonucleic acid in mouse intestinal tract, mitotic index of corneal epithelium, and serum corticosterone

    International Nuclear Information System (INIS)

    Scheving, L.E.; Tsai, T.H.; Powell, E.W.; Pasley, J.N.; Halberg, F.; Dunn, J.

    1983-01-01

    Investigations into the role of the suprachiasmatic nuclei (SCN) in the coordination of circadian rhythms have presented differing results. Several reports have shown that ablation of the suprachiasmatic nuclei (SCNA) alters the phase and amplitude of rhythms but does not abolish them. The present study investigates the effect of SCNA on the rhythms in cell proliferation in various regions of the intestinal tract as measured by the incorporation of [ 3 H]-thymidine into deoxyribonucleic acid, in the mitotic activity of the corneal epithelium, and in serum corticosterone levels. The study involved mice with verified lesions of the SCN (six to 13 mice per time point) and control groups of both sham-operated and unoperated mice (seven of each per time point). The mice were killed in groups that represented seven time points over a single 24 hr span (3 hr intervals with the 0800 hr sampled both at start and end of the series). The tissues examined were the tongue, esophagus, gastric stomach, and colon for DNA synthesis, the corneal epithelium for mitotic index, and blood serum for corticosterone level. The most consistent result of SCNA was a phase advance in the rhythms in cell proliferation in the tongue, esophagus, gastric stomach, colon, and corneal epithelium. A reduction in rhythm amplitude occurred in the tongue, esophagus, and corneal epithelium; however, there was an amplitude increase for the stomach, colon, and serum corticosterone. The mesor (rhythm-adjusted mean) was increased by SCNA in all tissues except the corneal epithelium. These findings further support the role of the suprachiasmatic nuclear area in the control of rhythms in cell proliferation and corticosterone production, by acting as a ''phase-resetter'' and as a modulator of rhythm amplitude

  8. Corneal Collagen Crosslinking Combined with Phototherapeutic Keratectomy and Photorefractive Keratectomy for Corneal Ectasia after Laser in situ Keratomileusis.

    Science.gov (United States)

    Zhu, Wei; Han, Yunfei; Cui, Changxia; Xu, Wenwen; Wang, Xuan; Dou, Xiaoxiao; Xu, Linlin; Xu, Yanyun; Mu, Guoying

    2018-01-01

    The aim of this study was to analyze the effects of corneal crosslinking (CXL) combined with phototherapeutic keratectomy (PTK) and photorefractive keratectomy (PRK) in halting the progression and improving the visual function of corneal ectasia after laser in situ keratomileusis (LASIK). PTK-PRK-CXL was performed on 14 eyes of 14 patients who developed corneal ectasia after LASIK. The visual acuity, spherical refraction and cylinder, corneal topography indices, thinnest corneal thickness (TCT), and endothelial cell count were evaluated at baseline and at 1, 3, 6, and 12 months postoperatively. The mean uncorrected visual acuity improved significantly from 0.64 ± 0.36 logMAR preoperatively to 0.19 ± 0.12 logMAR at 12 months of follow-up (p 0.05) beyond 6 months after treatment. PTK-PRK-CXL is a promising procedure to halt the progression of post-LASIK keratectasia with significant visual quality improvement. © 2018 S. Karger AG, Basel.

  9. Corneal neurotoxicity due to topical benzalkonium chloride.

    Science.gov (United States)

    Sarkar, Joy; Chaudhary, Shweta; Namavari, Abed; Ozturk, Okan; Chang, Jin-Hong; Yco, Lisette; Sonawane, Snehal; Khanolkar, Vishakha; Hallak, Joelle; Jain, Sandeep

    2012-04-06

    The aim of this study was to determine and characterize the effect of topical application of benzalkonium chloride (BAK) on corneal nerves in vivo and in vitro. Thy1-YFP+ neurofluorescent mouse eyes were treated topically with vehicle or BAK (0.01% or 0.1%). Wide-field stereofluorescence microscopy was performed to sequentially image the treated corneas in vivo every week for 4 weeks, and changes in stromal nerve fiber density (NFD) and aqueous tear production were determined. Whole-mount immunofluorescence staining of corneas was performed with antibodies to axonopathy marker SMI-32. Western immunoblot analyses were performed on trigeminal ganglion and corneal lysates to determine abundance of proteins associated with neurotoxicity and regeneration. Compartmental culture of trigeminal ganglion neurons was performed in Campenot devices to determine whether BAK affects neurite outgrowth. BAK-treated corneas exhibited significantly reduced NFD and aqueous tear production, and increased inflammatory cell infiltration and fluorescein staining at 1 week (P reduction in neurites occurred after BAK addition to compartmental cultures of dissociated trigeminal ganglion cells. Although both BAK doses (0.0001% and 0.001%) reduced nerve fiber length, the reduction was significantly more with the higher dose (P < 0.001). Topical application of BAK to the eye causes corneal neurotoxicity, inflammation, and reduced aqueous tear production.

  10. Inhibitory effects of regorafenib, a multiple tyrosine kinase inhibitor, on corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Halil Ibrahim Onder

    2014-04-01

    Full Text Available AIM:To evaluate the inhibitory effects of regorafenib (BAY 73-4506, a multikinase inhibitor, on corneal neovascularization (NV.METHODS:Thirty adult male Sprague-Dawley rats weighing 250-300 g, were used. Corneal NV was induced by NaOH in the left eyes of each rat. Following the establishment of alkali burn, the animals were randomized into five groups according to topical treatment. Group 1 (n = 6 received 0.9% NaCl, Group 2 (n = 6 received dimethyl sulfoxide, Group 3 (n = 6 received regorafenib 1 mg/mL, Group 4 (n =6 received bevacizumab 5 mg/mL and Group 5 (n = 6 received 0.1% dexamethasone phosphate. On the 7d, the corneal surface covered with neovascular vessels was measured on photographs as the percentage of the cornea’s total area using computer-imaging analysis. The corneas obtained from rats were semiquantitatively evaluated for caspase-3 and vascular endothelial growth factor by immunostaining.RESULTS:A statistically significant difference in the percent area of corneal NV was found among the groups (P <0.001. Although the Group 5 had the smallest percent area of corneal NV, there was no difference among Groups 3, 4 and 5 (P >0.005. There was a statistically significant difference among the groups in apoptotic cell density (P = 0.002. The staining intensity of vascular endothelial growth factor in the epithelial and endothelial layers of cornea was significantly different among the groups (P <0.05. The staining intensity of epithelial and endothelial vascular endothelial growth factor was significantly weaker in Groups 3, 4 and 5 than in Groups 1 and 2.CONCLUSION: Topical administration of regorafenib 1 mg/mL is partly effective for preventing alkali-induced corneal NV in rats.

  11. Spontaneous Corneal Hydrops in a Patient with a Corneal Ulcer

    Directory of Open Access Journals (Sweden)

    Hatim Batawi

    2016-01-01

    Full Text Available Purpose: We report the case of a 77-year-old man with no history of keratoconus or other ectatic disorders who presented with corneal hydrops in the setting of a corneal ulcer. The risk factors, pathogenesis and treatment options of corneal hydrops are discussed. Method: This is an observational case report study. Results: A 77-year-old man presented with a 1-day history of severe pain, redness, mucous discharge and photophobia in the right eye. A slit-lamp examination of the right eye showed an area of focal corneal edema and protrusion. Within the area of edema and protrusion, there was an infiltrate with an overlying epithelial defect consistent with an infectious corneal ulcer. The Seidel test showed no leakage, so a clinical diagnosis of corneal hydrops associated with nonperforated corneal ulcer was made. With appropriate antibiotic treatment, the corneal ulcer and hydrops both resolved over a 1-month period. Conclusion: Corneal hydrops can occur in the setting of corneal infections.

  12. Corneal biomechanical properties from air-puff corneal deformation imaging

    Science.gov (United States)

    Marcos, Susana; Kling, Sabine; Bekesi, Nandor; Dorronsoro, Carlos

    2014-02-01

    The combination of air-puff systems with real-time corneal imaging (i.e. Optical Coherence Tomography (OCT), or Scheimpflug) is a promising approach to assess the dynamic biomechanical properties of the corneal tissue in vivo. In this study we present an experimental system which, together with finite element modeling, allows measurements of corneal biomechanical properties from corneal deformation imaging, both ex vivo and in vivo. A spectral OCT instrument combined with an air puff from a non-contact tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal deformation of the corneal apex. Quantitative analysis allows direct extraction of several deformation parameters, such as apex indentation across time, maximal indentation depth, temporal symmetry and peak distance at maximal deformation. The potential of the technique is demonstrated and compared to air-puff imaging with Scheimpflug. Measurements ex vivo were performed on 14 freshly enucleated porcine eyes and five human donor eyes. Measurements in vivo were performed on nine human eyes. Corneal deformation was studied as a function of Intraocular Pressure (IOP, 15-45 mmHg), dehydration, changes in corneal rigidity (produced by UV corneal cross-linking, CXL), and different boundary conditions (sclera, ocular muscles). Geometrical deformation parameters were used as input for inverse finite element simulation to retrieve the corneal dynamic elastic and viscoelastic parameters. Temporal and spatial deformation profiles were very sensitive to the IOP. CXL produced a significant reduction of the cornea indentation (1.41x), and a change in the temporal symmetry of the corneal deformation profile (1.65x), indicating a change in the viscoelastic properties with treatment. Combining air-puff with dynamic imaging and finite element modeling allows characterizing the corneal biomechanics in-vivo.

  13. Challenges in pediatric endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Vikas Mittal

    2014-01-01

    Full Text Available We performed endothelial keratoplasty (EK in three eyes of two siblings (2.5 years, male and 3.5 years, female with congenital hereditary endothelial dystrophy (CHED and report the intraoperative and postoperative difficulties. Repeated iris prolapse, apprehension of crystalline lens touch due to positive vitreous pressure, and need for frequent air injections to attach the graft were intraoperative challenges in all three eyes. These were addressed by use of Sheet′s glide instead of Busin′s glide during graft insertion and suturing of main and side ports before air injection. One eye had graft dislocation on second postoperative day due to eye rubbing by the child. Graft was repositioned with air and a venting incision was created. Postoperative examination required repeated general anesthesia. Corneal edema resolved completely in all three eyes. Present case series highlights the possible intraoperative and postoperative challenges and their solutions in pediatric EK for CHED.

  14. Corneal endothelium in xeroderma pigmentosum: clinical specular microscopy study.

    Science.gov (United States)

    Mohamed, Ashik; Peguda, Rajini; Ramappa, Muralidhar; Ali, Mohammad Javed; Chaurasia, Sunita

    2016-06-01

    Xeroderma pigmentosum is a condition caused due to a defective DNA repair mechanism when exposed to ultraviolet radiation. Many of the patients with this disorder develop severely oedematous cornea with varying degrees of anterior corneal haze, which necessitates a full-thickness keratoplasty or selective endothelial keratoplasty. Presence of corneal oedema suggests that these patients have a dysfunctional endothelium. The purpose of this study is to evaluate the corneal endothelium in the patients with xeroderma pigmentosum when clinical specular microscopy was feasible. Thirteen patients with classic skin changes of xeroderma pigmentosum were included in the study conducted during January 2010-December 2012. An age-matched group of 13 volunteers were included as controls who were emmetropes without any history of ocular or systemic illness. Corneal endothelium was assessed using specular microscopy from the central clear area of cornea. The mean age of the patients with xeroderma pigmentosum was 16.6±7.2 years and that of the controls was 17.4±6.9 years (p=0.78). The number of analysed cells and endothelial cell density were significantly higher in controls (pxeroderma pigmentosum (p≤0.007). The specular microscopic findings in patients with xeroderma pigmentosum are suggestive of an accelerated endothelial cell loss. It is pertinent that the treating physicians must be involved in emphasising proper ocular protection from ultraviolet radiation to prevent avoidable blindness from xeroderma pigmentosum. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Study of light scattering using C-Quant® in patients with Fuchs' endothelial dystrophy: A pilot study.

    Science.gov (United States)

    Castaño-Martín, B; Gros-Otero, J; Martínez, J; Teus, M

    2017-11-01

    The purpose of this study was to determine the light scattering in patients with Fuchs' endothelial dystrophy without clinically significant corneal oedema, and evaluate its relationship with endothelial cell count, corneal thickness, and corneal biomechanical parameters. The values of light scattering were measured by C-Quant ® (Oculus Optikgeräte GmbH, Germany) in 32 eyes of 17 patients diagnosed with Fuchs' endothelial dystrophy without clinically significant corneal oedema. Corneal biomechanical properties were determined using ORA (ocular response) and Corvis ST ® (tonometry). A light scattering value outside the normal range was observed in 93.8% of eyes studied. No statistically significant association (P>.05) was found between the values of the measured light scattering by C-Quant ® and endothelial count, pachymetry, or corneal biomechanical properties. In this study, changes were found in the values of light scattering values of patients with corneal Fuchs' endothelial dystrophy. This change does not appear to correlate significantly with disease severity. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Neurotrophic corneal and conjunctival xerosis

    Directory of Open Access Journals (Sweden)

    Svetlana Gennadyevna Zhurova

    2014-03-01

    Full Text Available Purpose: to develop a method of surgical treatment of patients with corneal ulcers of xerotic etiology and evaluate its efficacy in different time periods after operation. Materials and methods: 68 patients (86 eyes with severe dry eye syndrome complicated by xerotic corneal ulcers were examined. In all patients, the ulcer defect was covered with conjunctiva and amniotic membrane. The operation was combined with an outer tarsorrhaphy and temporary blepharorraphy. Results: All 86 eyes (100% achieved total closure of the ulcer defect, sealing of any perforation and maintaining of corneal transparency beyond the ulcer defect. Conclusion: Surgical closure of corneal ulcers with conjunctiva is an effective method of treatment of xerotic corneal ulcers. It could be recommended in patients with corneal perforation and tendency of descemetocele formation.

  17. Protein kinase C-α signals P115RhoGEF phosphorylation and RhoA activation in TNF-α-induced mouse brain microvascular endothelial cell barrier dysfunction

    Directory of Open Access Journals (Sweden)

    Deng Xiaolu

    2011-04-01

    Full Text Available Abstract Background Tumor necrosis factor-α (TNF-α, a proinflammatory cytokine, is capable of activating the small GTPase RhoA, which in turn contributes to endothelial barrier dysfunction. However, the underlying signaling mechanisms remained undefined. Therefore, we aimed to determine the role of protein kinase C (PKC isozymes in the mechanism of RhoA activation and in signaling TNF-α-induced mouse brain microvascular endothelial cell (BMEC barrier dysfunction. Methods Bend.3 cells, an immortalized mouse brain endothelial cell line, were exposed to TNF-α (10 ng/mL. RhoA activity was assessed by pull down assay. PKC-α activity was measured using enzyme assasy. BMEC barrier function was measured by transendothelial electrical resistance (TER. p115RhoGEF phosphorylation was detected by autoradiography followed by western blotting. F-actin organization was observed by rhodamine-phalloidin staining. Both pharmacological inhibitors and knockdown approaches were employed to investigate the role of PKC and p115RhoGEF in TNF-α-induced RhoA activation and BMEC permeability. Results We observed that TNF-α induces a rapid phosphorylation of p115RhoGEF, activation of PKC and RhoA in BMECs. Inhibition of conventional PKC by Gö6976 mitigated the TNF-α-induced p115RhoGEF phosphorylation and RhoA activation. Subsequently, we found that these events are regulated by PKC-α rather than PKC-β by using shRNA. In addition, P115-shRNA and n19RhoA (dominant negative mutant of RhoA transfections had no effect on mediating TNF-α-induced PKC-α activation. These data suggest that PKC-α but not PKC-β acts as an upstream regulator of p115RhoGEF phosphorylation and RhoA activation in response to TNF-α. Moreover, depletion of PKC-α, of p115RhoGEF, and inhibition of RhoA activation also prevented TNF-α-induced stress fiber formation and a decrease in TER. Conclusions Taken together, our results show that PKC-α phosphorylation of p115RhoGEF mediates TNF

  18. Corneal Neurotoxicity Due to Topical Benzalkonium Chloride

    OpenAIRE

    Sarkar, Joy; Chaudhary, Shweta; Namavari, Abed; Ozturk, Okan; Chang, Jin-Hong; Yco, Lisette; Sonawane, Snehal; Khanolkar, Vishakha; Hallak, Joelle; Jain, Sandeep

    2012-01-01

    Topical application of benzalkonium chloride (BAK) to the eye causes dose-related corneal neurotoxicity. Corneal inflammation and reduction in aqueous tear production accompany neurotoxicity. Cessation of BAK treatment leads to recovery of corneal nerve density.

  19. Distrofia corneal granular

    Directory of Open Access Journals (Sweden)

    Alexeide de la C Castillo Pérez

    Full Text Available Las distrofias corneales constituyen un conjunto de enfermedades que presentan, en su mayoría, una baja incidencia y se caracterizan por acúmulo de material hialino o amiloide que disminuyen la transparencia corneal. La distrofia granular es una enfermedad autosómica dominante que presenta opacidades grises en el estroma superficial central de la córnea y se hacen visibles en la primera y segunda décadas de la vida, lo que provoca disminución de la visión más significativa cerca de los 40 años de edad. Presentamos dos casos clínicos de distrofia granular en pacientes hermanos de diferentes sexos, quienes acudieron a la consulta y refirieron visión nublada. El estudio de la historia familiar nos ayuda en el correcto diagnóstico y la biomicroscopia constituye el elemento más importante.

  20. Inverse cutting of posterior lamellar corneal grafts by a femtosecond laser

    DEFF Research Database (Denmark)

    Hjortdal, Jesper; Nielsen, Esben; Vestergaard, Anders Højslet

    2012-01-01

    (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. Conclusions: Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months...

  1. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  2. SUITABILITY OF CORNEAL TISSUE FOR TRANSPLANTATION PROCURED FROM HANGING CASES

    Directory of Open Access Journals (Sweden)

    Rekha Gyanchand

    2017-06-01

    Full Text Available BACKGROUND Requirement of donor cornea is essential to target the corneal blind. The best method to procure such corneas is from any major hospitals, which has a mortuary facility. The eye donation with hanging as the cause of death is very common in a mortuary setup. Some factors that are concerning regarding corneas procured from death due to hanging is the prolonged exposure of the cornea at the time of death, the exact time of death is not known, most of the cadavers are refrigerated for investigations as these arrive at the mortuary usually at night. Due to these reasons, the corneal surgeons are hesitant to use corneas procured from death due to hanging for corneal transplantation. Analysing these corneas would contribute to a great extent to the donor cornea pool in providing sight to the corneal blind, especially as majority are young individuals who commit suicide by hanging. In this study, the donor corneas were analysed with regards to corneal epithelial defect, endothelial cell morphology and utilisation of these corneas for transplantation. The aim of the HCRP study is to analyse the effect of death due to hanging on donor cornea. 1. Corneal epithelial status. 2. Corneal endothelial cell morphology. 3. Utilisation of corneas for transplantation. MATERIALS AND METHODS Donor corneas from 22 donors who died due to hanging were procured from hospital mortuary. All the 44 corneas were transplanted. Various parameters like demography, death to enucleation time, cadaver preservation in cold storage, endothelial cell density and utilisation of cornea for transplantation were noted. Design- Retrospective study. Statistical Analysis- Descriptive statistics, Pearson and Spearman correlation and Chi-square test were used to test the hypotheses. RESULTS Out of the 44 corneas analysed, 75% of the donors were refrigerated as a part of medicolegal investigations protocol. The average DTP time was 12 hours in refrigerated group and 5 hours in non

  3. Spontaneous regression of epithelial downgrowth from clear corneal phacoemulsification wound

    Directory of Open Access Journals (Sweden)

    Ryan M. Jaber

    2018-06-01

    Full Text Available Purpose: To report a case of spontaneous regression of optical coherence tomography (OCT and confocal microscopy-supported epithelial downgrowth associated with clear corneal phacoemulsification wound. Observations: A 66-year-old Caucasian male presented two years after phacoemulsification in the left eye with an enlarging cornea endothelial lesion in that eye. His early post-operative course had been complicated by corneal edema and iris transillumination defects. The patient presented to our clinic with a large geographic sheet of epithelial downgrowth and iris synechiae to the temporal clear corneal wound. His vision was correctable to 20/25 in his left eye. Anterior segment OCT showed a hyperreflective layer on the posterior cornea with an abrupt transition that corresponded to the clinical transition zone of the epithelial downgrowth. Confocal microscopy showed polygonal cells with hyperreflective nuclei suggestive of epithelial cells in the area of the lesion with a transition to a normal endothelial cell mosaic. Given the lack of glaucoma or inflammation and the relatively good vision, the plan was made to closely monitor for progression with the anticipation that he may require aggressive surgery. Over course of subsequent follow-up visits at three, seven and ten months; the endothelial lesion receded significantly. Confocal imaging in the area of the previously affected cornea showed essentially normal morphology with anan endothelial cell count of 1664 cells/mm2. Conclusions and importance: Epithelial downgrowth may spontaneously regress. Though the mechanism is yet understood, contact inhibition of movement may play a role. Despite this finding, epithelial downgrowth is typically a devastating process requiring aggressive treatment. Keywords: Epithelial downgrowth, Spontaneous regression, Confocal microscopy, Contact inhibition of movement

  4. Signaling hierarchy regulating human endothelial cell development.

    Science.gov (United States)

    Kelly, Melissa A; Hirschi, Karen K

    2009-05-01

    Our present knowledge of the regulation of mammalian endothelial cell differentiation has been largely derived from studies of mouse embryonic development. However, unique mechanisms and hierarchy of signals that govern human endothelial cell development are unknown and, thus, explored in these studies. Using human embryonic stem cells as a model system, we were able to reproducibly and robustly generate differentiated endothelial cells via coculture on OP9 marrow stromal cells. We found that, in contrast to studies in the mouse, bFGF and VEGF had no specific effects on the initiation of human vasculogenesis. However, exogenous Ihh promoted endothelial cell differentiation, as evidenced by increased production of cells with cobblestone morphology that coexpress multiple endothelial-specific genes and proteins, form lumens, and exhibit DiI-AcLDL uptake. Inhibition of BMP signaling using Noggin or BMP4, specifically, using neutralizing antibodies suppressed endothelial cell formation; whereas, addition of rhBMP4 to cells treated with the hedgehog inhibitor cyclopamine rescued endothelial cell development. Our studies revealed that Ihh promoted human endothelial cell differentiation from pluripotent hES cells via BMP signaling, providing novel insights applicable to modulating human endothelial cell formation and vascular regeneration for human clinical therapies.

  5. Correction of low corneal astigmatism in cataract surgery.

    Science.gov (United States)

    Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele

    2015-01-01

    To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  6. Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision.

    Science.gov (United States)

    Assaf, Ahmed; Roshdy, Maged Maher

    2013-01-01

    This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification. This study includes 139 consecutive cataractous eyes (nuclear color 2-4, according to the Lens Opacities Classification System III [LOCSIII]) of 82 patients undergoing cataract surgery through a 2.2 mm corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature(®) system with the Ellips™ FX transversal continuous ultrasound (US) mode for group I (mean age: 65.33 ± 6.97 years), and we used the Infiniti(®) system with the OZil(®) Intelligent Phaco (IP) torsional US mode for group II (mean age: 64.02 ± 7.55 years). The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated. All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 ± 0.06 mm in both groups (P = 0.75). In terms of corneal endothelial cell density, neither preoperative (I vs II: 2304.1 ± 122.5 cell/mm(2) vs 2315.6 ± 83.1 cell/mm(2), P = 0.80) nor postoperative (I vs II: 2264.1 ± 124.3 cell/mm(2) vs 2270.3 ± 89.9 cell/mm(2), P = 0.98) differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% ± 1.6% and 2.0% ± 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P = 0.40) and postoperatively (P = 0.68) in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 ± 23.6 μm and 24.0 ± 24.0 μm in groups I and II, respectively (P = 0.1). Ellips™ FX transversal and OZil(®) IP torsional phacoemulsification modes are safe for performing cataract surgery, inducing minimal corneal thickness and endothelial changes.

  7. Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision

    Directory of Open Access Journals (Sweden)

    Assaf A

    2013-01-01

    Full Text Available Ahmed Assaf, Maged Maher RoshdyOphthalmology Department, Ain Shams University, Cairo, EgyptPurpose: This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification.Patients and methods: This study includes 139 consecutive cataractous eyes (nuclear color 2–4, according to the Lens Opacities Classification System III [LOCSIII] of 82 patients undergoing cataract surgery through a 2.2 mm corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature® system with the Ellips™ FX transversal continuous ultrasound (US mode for group I (mean age: 65.33 ± 6.97 years, and we used the Infiniti® system with the OZil® Intelligent Phaco (IP torsional US mode for group II (mean age: 64.02 ± 7.55 years. The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated.Results: All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 ± 0.06 mm in both groups (P = 0.75. In terms of corneal endothelial cell density, neither preoperative (I vs II: 2304.1 ± 122.5 cell/mm2 vs 2315.6 ± 83.1 cell/mm2, P = 0.80 nor postoperative (I vs II: 2264.1 ± 124.3 cell/mm2 vs 2270.3 ± 89.9 cell/mm2, P = 0.98 differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% ± 1.6% and 2.0% ± 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P = 0.40 and postoperatively (P = 0.68 in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 ± 23.6 µm and 24.0 ± 24.0 µm in groups I and II, respectively (P = 0.1.Conclusion: Ellips™ FX transversal and OZil® IP torsional

  8. Dynamic corneal deformation response and integrated corneal tomography

    Directory of Open Access Journals (Sweden)

    Marcella Q Salomão

    2018-01-01

    Full Text Available Measuring corneal biomechanical properties is still challenging. There are several clinical applications for biomechanical measurements, including the detection of mild or early forms of ectatic corneal diseases. This article reviews clinical applications for biomechanical measurements provided by the Corvis ST dynamic non contact tonometer

  9. Extracellular S100A4(mts1) stimulates invasive growth of mouse endothelial cells and modulates MMP-13 matrix metalloproteinase activity

    DEFF Research Database (Denmark)

    Schmidt-Hansen, Birgitte; Ornås, Dorte; Grigorian, Mariam

    2004-01-01

    with the transcriptional modulation of genes involved in the proteolytic degradation of extracellular matrix (ECM). Treatment of SVEC 4-10 with the S100A4 protein leads to the transcriptional activation of collagenase 3 (MMP-13) mRNA followed by subsequent release of the protein from the cells. Beta-casein zymography...... demonstrates enhancement of proteolytic activity associated with MMP-13. This observation indicates that extracellular S100A4 stimulates the production of ECM degrading enzymes from endothelial cells, thereby stimulating the remodeling of ECM. This could explain the angiogenic and metastasis...

  10. Corneal Opacity in Domestic Ducks Experimentally Infected With H5N1 Highly Pathogenic Avian Influenza Virus.

    Science.gov (United States)

    Yamamoto, Y; Nakamura, K; Yamada, M; Mase, M

    2016-01-01

    Domestic ducks can be a key factor in the regional spread of H5N1 highly pathogenic avian influenza (HPAI) virus in Asia. The authors performed experimental infections to examine the relationship between corneal opacity and H5N1 HPAI virus infection in domestic ducks (Anas platyrhyncha var domestica). A total of 99 domestic ducks, including 3 control birds, were used in the study. In experiment 1, when domestic ducks were inoculated intranasally with 2 H5N1 HPAI viruses, corneal opacity appeared more frequently than neurologic signs and mortality. Corneal ulceration and exophthalmos were rare findings. Histopathologic examinations of the eyes of domestic ducks in experiment 2 revealed that corneal opacity was due to the loss of corneal endothelial cells and subsequent keratitis with edema. Influenza viral antigen was detected in corneal endothelial cells and some other ocular cells by immunohistochemistry. Results suggest that corneal opacity is a characteristic and frequent finding in domestic ducks infected with the H5N1 HPAI virus. Confirming this ocular change may improve the detection rate of infected domestic ducks in the field. © The Author(s) 2015.

  11. In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty.

    Science.gov (United States)

    Brown, Jamin S; Wang, Danling; Li, Xiaoli; Baluyot, Florence; Iliakis, Bernie; Lindquist, Thomas D; Shirakawa, Rika; Shen, Tueng T; Li, Xingde

    2008-08-01

    To use optical coherence tomography (OCT) as a noninvasive tool to perform in situ characterization of eye bank corneal tissue processed for lamellar keratoplasty. A custom-built ultrahigh-resolution OCT (UHR-OCT) was used to characterize donor corneal tissue that had been processed for lamellar keratoplasty. Twenty-seven donor corneas were analyzed. Four donor corneas were used as controls, whereas the rest were processed into donor corneal buttons for lamellar transplantation by using hand dissection, a microkeratome, or a femtosecond laser. UHR-OCT was also used to noninvasively characterize and monitor the viable corneal tissue immersed in storage medium over 3 weeks. The UHR-OCT captured high-resolution images of the donor corneal tissue in situ. This noninvasive technique showed the changes in donor corneal tissue morphology with time while in storage medium. The characteristics of the lamellar corneal tissue with each processing modality were clearly visible by UHR-OCT. The in situ characterization of the femtosecond laser-cut corneal tissue was noted to have more interface debris than shown by routine histology. The effects of the femtosecond laser microcavitation bubbles on the corneal tissue were well visualized at the edges of the lamellar flap while in storage medium. The results of our feasibility study show that UHR-OCT can provide superb, in situ microstructural characterization of eye bank corneal tissue noninvasively. The UHR-OCT interface findings and corneal endothelial disc thickness uniformity analysis are valuable information that may be used to optimize the modalities and parameters for lamellar tissue processing. The UHR-OCT is a powerful approach that will allow us to further evaluate the tissue response to different processing techniques for posterior lamellar keratoplasty. It may also provide information that can be used to correlate with postoperative clinical outcomes. UHR-OCT has the potential to become a routine part of tissue

  12. Remote manipulation of posterior lamellar corneal grafts using a magnetic field.

    Science.gov (United States)

    Nahum, Yoav; Barliya, Tilda; Bahar, Irit; Livnat, Tami; Nisgav, Yael; Weinberger, Dov

    2013-06-01

    In posterior lamellar keratoplasty procedures such as Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty, the lamellar graft is manipulated directly or by injecting an air bubble. This preliminary study sought to evaluate the feasibility of guiding lamellar corneal grafts by generating a magnetic field. Rabbit and porcine Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty grafts were manually produced and immersed in a ferromagnetic solution containing nanomagnetic particles conjugated to streptavidin or in gadoteric acid. For the feasibility study, grafts were transferred to an artificial anterior chamber or plastic test tube and a magnetic field was generated with a handheld NdFeB disc magnet. The presence and the sustainability of graft motion were documented under various conditions. For the semiquantitative study, whole or partial grafts were transferred to a plastic test tube after immersion, and the amount of tissue retraction induced by the remote magnet was graded. The grafts were successfully manipulated in all directions by the magnet, from a distance of up to 7 mm. They remained ferromagnetic more than 24 hours after immersion in the ferromagnetic solutions. The degree of retraction was affected by graft size, immersion time, time from immersion, and immersion solution. Posterior lamellar corneal grafts may be made ferromagnetic and remotely manipulated by creation of a magnetic field. The ferromagnetic properties are adjustable. This technique holds promise in attaching and repositioning grafts during keratoplasty. Further research is needed to assess the possible effects of ferromagnetic solutions on corneal endothelial cells and on lamellar graft clarity.

  13. Role of corneal collagen fibrils in corneal disorders and related pathological conditions

    Directory of Open Access Journals (Sweden)

    Hong-Yan Zhou

    2017-05-01

    Full Text Available The cornea is a soft tissue located at the front of the eye with the principal function of transmitting and refracting light rays to precisely sense visual information. Corneal shape, refraction, and stromal stiffness are to a large part determined by corneal fibrils, the arrangements of which define the corneal cells and their functional behaviour. However, the modality and alignment of native corneal collagen lamellae are altered in various corneal pathological states such as infection, injury, keratoconus, corneal scar formation, and keratoprosthesis. Furthermore, corneal recuperation after corneal pathological change is dependent on the balance of corneal collagen degradation and contraction. A thorough understanding of the characteristics of corneal collagen is thus necessary to develop viable therapies using the outcome of strategies using engineered corneas. In this review, we discuss the composition and distribution of corneal collagens as well as their degradation and contraction, and address the current status of corneal tissue engineering and the progress of corneal cross-linking.

  14. Toxicity of methods of implant material sterilization on corneal endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Singh, G.; Boehnke, Mv.; von Domarus, D.; Draeger, J.

    1985-11-01

    The toxicity of different procedures utilized for the sterilization of intraocular implant material was assessed on the endothelium of organ-cultured porcine corneas. Polymethylmethacrylate lenses sterilized by treatment with sodium hydroxide (NaOH), ethylene oxide, formaldehyde, and gamma radiation were added to a culture medium containing normal porcine corneas. Considering the viability of endothelial cells, appearance of intracellular degenerative vacuoles, and denudation of corneal Descemet's membrane as criterion for the evaluation of toxicity of different methods of sterilization, the NaOH-treated lenses were found to be the least toxic to porcine corneal endothelium. Phase-contrast microscopy and vital staining of the endothelium permitted direct viewing of the endothelium aiding in the assessment of toxicity.

  15. Phototoxic effects of 8-methoxypsoralen on rabbit corneal endothelium

    Energy Technology Data Exchange (ETDEWEB)

    Menon, I.A.; Basu, P.K.; Hasany, S.M.; Persad, S.D. (Univ. of Toronto, Ontario (Canada))

    1989-01-01

    The phototoxic effects of 8-methoxypsoralen (8-MOP) were investigated using the rabbit corneal endothelium in organ culture. The corneas were divided into four groups: (a) irradiated with a mercury vapor lamp (emitting UVA and visible radiation) in the presence of 8-MOP (experimental), (b) irradiated without 8-MOP (control A), (c) incubated with 8-MOP (control B) and (d) incubated without 8-MOP (control C). Specular and light microscopic examination showed that the experimental corneas had greater cellular damage compared to the control corneas. The effects of 8-MOP were restricted to certain localized areas of the cornea. However there was no significant difference in the amounts of 51Cr released from the labelled experimental and control corneas. These results show phototoxic damage of the corneal endothelial cells.

  16. Neuroblast survival depends on mature vascular network formation after mouse stroke: role of endothelial and smooth muscle progenitor cell co-administration.

    Science.gov (United States)

    Nih, Lina R; Deroide, Nicolas; Leré-Déan, Carole; Lerouet, Dominique; Soustrat, Mathieu; Levy, Bernard I; Silvestre, Jean-Sébastien; Merkulova-Rainon, Tatiana; Pocard, Marc; Margaill, Isabelle; Kubis, Nathalie

    2012-04-01

    Pro-angiogenic cell-based therapies constitute an interesting and attractive approach to enhancing post-stroke neurogenesis and decreasing neurological deficit. However, most new stroke-induced neurons die during the first few weeks after ischemia, thus impairing total recovery. Although the neovascularization process involves different cell types and various growth factors, most cell therapy protocols are based on the biological effects of single-cell-type populations or on the administration of heterogeneous populations of progenitors, namely human cord blood-derived CD34(+) cells, with scarce vascular progenitor cells. Tight cooperation between endothelial cells and smooth muscle cells/pericytes is critical for the development of functional neovessels. We hypothesized that neuroblast survival in stroke brain depends on mature vascular network formation. In this study, we injected a combination of endothelial progenitor cells (EPCs) and smooth muscle progenitor cells (SMPCs), isolated from human umbilical cord blood, into a murine model of permanent focal ischemia induced by middle cerebral artery occlusion. The co-administration of SMPCs and EPCs induced enhanced angiogenesis and vascular remodeling in the peri-infarct and infarct areas, where vessels exhibited a more mature phenotype. This activation of vessel growth resulted in the maintenance of neurogenesis and neuroblast migration to the peri-ischemic cortex. Our data suggest that a mature vascular network is essential for neuroblast survival after cerebral ischemia, and that co-administration of EPCs and SMPCs may constitute a novel therapeutic strategy for improving the treatment of stroke. © 2012 The Authors. European Journal of Neuroscience © 2012 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  17. Corneal structure and transparency

    Science.gov (United States)

    Meek, Keith M.; Knupp, Carlo

    2015-01-01

    The corneal stroma plays several pivotal roles within the eye. Optically, it is the main refracting lens and thus has to combine almost perfect transmission of visible light with precise shape, in order to focus incoming light. Furthermore, mechanically it has to be extremely tough to protect the inner contents of the eye. These functions are governed by its structure at all hierarchical levels. The basic principles of corneal structure and transparency have been known for some time, but in recent years X-ray scattering and other methods have revealed that the details of this structure are far more complex than previously thought and that the intricacy of the arrangement of the collagenous lamellae provides the shape and the mechanical properties of the tissue. At the molecular level, modern technologies and theoretical modelling have started to explain exactly how the collagen fibrils are arranged within the stromal lamellae and how proteoglycans maintain this ultrastructure. In this review we describe the current state of knowledge about the three-dimensional stromal architecture at the microscopic level, and about the control mechanisms at the nanoscopic level that lead to optical transparency. PMID:26145225

  18. Analysis of biological characteristics of corneal endothelium in old patients with high myopia

    Directory of Open Access Journals (Sweden)

    Ya-Qiong Chen

    2014-11-01

    Full Text Available AIM: To analyze quantitatively the biological characteristics of corneal endothelium in old patients of high myopia with non-contact automatic corneal endothelial microscope.METHODS:A total of 189 old patients(197 eyeswere divided into the high myopia group and the normal control group according to refractive diopter, in which the former 98 cases(103 eyes, the latter 91 cases(94 eyes. The hexagonal cell(6A, the coefficient of variation(CV, the average cell area(AVE, the average cell density(CDand the central corneal thickness(CCTwere measured by non-contact automatic corneal endothelium. SPSS 14.0 software was used to analyze their percentage. Z-test was used to compare the mean and Chi-square test was used to compare the rate in between. RESULTS: The average cell density in high myopia patients decreased, but there were 14 eyes >3 000/mm2, 11 eyes 2 and 78 eyes in the 2 000~3 000/mm2, there were each 0 eye, 3 eyes and 91 eyes respectively in the normal control group. There was statistically significant difference between high myopia group and control(χ2=19.11, PPP>0.05. CONCLUSION: There will provide a reference valuable for clinical surgeon. Because according to the changes of parameters and morphology of the corneal endothelial cells, we can understand the repair ability, to predict the consequence of the treatment, in order to determine the design and the choice of a surgical.

  19. Corneal markers of diabetic neuropathy.

    Science.gov (United States)

    Pritchard, Nicola; Edwards, Katie; Shahidi, Ayda M; Sampson, Geoff P; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan

    2011-01-01

    Diabetic neuropathy is a significant clinical problem that currently has no effective therapy, and in advanced cases, leads to foot ulceration and lower limb amputation. The accurate detection, characterization and quantification of this condition are important in order to define at-risk patients, anticipate deterioration, monitor progression, and assess new therapies. This review evaluates novel corneal methods of assessing diabetic neuropathy. Two new noninvasive corneal markers have emerged, and in cross-sectional studies have demonstrated their ability to stratify the severity of this disease. Corneal confocal microscopy allows quantification of corneal nerve parameters and noncontact corneal esthesiometry, the functional correlate of corneal structure, assesses the sensitivity of the cornea. Both these techniques are quick to perform, produce little or no discomfort for the patient, and are suitable for clinical settings. Each has advantages and disadvantages over traditional techniques for assessing diabetic neuropathy. Application of these new corneal markers for longitudinal evaluation of diabetic neuropathy has the potential to reduce dependence on more invasive, costly, and time-consuming assessments, such as skin biopsy.

  20. Sphingosine-1-Phosphate/Sphingosine-1-Phosphate Receptor 2 Axis Can Promote Mouse and Human Primary Mast Cell Angiogenic Potential through Upregulation of Vascular Endothelial Growth Factor-A and Matrix Metalloproteinase-2

    Directory of Open Access Journals (Sweden)

    Alena Chumanevich

    2016-01-01

    Full Text Available Mast cells (MC are present in most vascularized tissues around the vasculature likely exerting immunomodulatory functions. Endowed with diverse mediators, resident MC represent first-line fine-tuners of local microenvironment. Sphingosine-1-phosphate (S1P functions as a pluripotent signaling sphingolipid metabolite in health and disease. S1P formation occurs at low levels in resting MC and is upregulated upon activation. Its export can result in type 2 S1P receptor- (S1PR2- mediated stimulation of MC, further fueling inflammation. However, the role of S1PR2 ligation in proangiogenic vascular endothelial growth factor- (VEGF- A and matrix metalloproteinase- (MMP- 2 release from MC is unknown. Using a preclinical MC-dependent model of acute allergic responses and in vitro stimulated primary mouse bone marrow-derived MC (BMMC or human primary skin MC, we report that S1P signaling resulted in substantial amount of VEGF-A release. Similar experiments using S1pr2-deficient mice or BMMC or selective S1P receptor agonists or antagonists demonstrated that S1P/S1PR2 ligation on MC is important for VEGF-A secretion. Further, we show that S1P stimulation triggered transcriptional upregulation of VEGF-A and MMP-2 mRNA in human but not in mouse MC. S1P exposure also triggered MMP-2 secretion from human MC. These studies identify a novel proangiogenic axis encompassing MC/S1P/S1PR2 likely relevant to inflammation.

  1. Corneal edema and keratitis following selective laser trabeculoplasty.

    Science.gov (United States)

    Liu, Erica Tan; Seery, Loren S; Arosemena, Analisa; Lamba, Tania; Chaya, Craig J

    2017-06-01

    To describe three cases of keratitis following Selective Laser Trabeculoplasty (SLT). Three females with a history of glaucoma presented with corneal edema, keratitis (endothelial, epithelial) and decreased visual acuity shortly after SLT. There was variable resolution of symptoms after starting treatment with oral antiherpetics and topical steroids. With the increase in usage of SLT as a treatment for glaucoma and subsequent reports of keratitis, it is imperative for ophthalmic surgeons to be aware of herpes simplex as a possible risk factor. Prompt treatment with antivirals and steroids can potentially prevent scarring and permanent damage to the cornea.

  2. Effect of transfer of donor corneal tissue from McCarey–Kaufmann medium to Optisol-GS on corneal endothelium

    Directory of Open Access Journals (Sweden)

    Neha Kapur

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate the effect of transfer of donor corneal tissue from McCarey–Kaufmann (MK medium to Optisol-GS on corneal endothelium. Methods: This was a prospective, randomized comparative study. Twenty paired human donor corneal tissues of optical quality were retrieved. One tissue of the pair was preserved in Optisol-GS preservative medium (Group A and other tissue of the pair in MK medium (Group B at the time of corneoscleral disc excision. Within 12 h of retrieval, each cornea was evaluated using slit-lamp biomicroscopic examination and specular microscopic analysis. Group B corneas were transferred to Optisol-GS medium within 48–53 h of retrieval. Specular analysis of the paired corneas was repeated 3 h after transferring to Optisol-GS. On day 7 of storage, specular analysis of both the tissues was repeated. Results: The average age of the donor at the time of death was 29 years (16–68 years. The reduction in endothelial cell count, from baseline, in Groups A and B was 5.5% and 5.8% (P = 0.938 on the 3rd day and 8.2% and 12.6% (P = 0.025 on the 7th day, respectively, postretrieval. The coefficient of variation (CV increased by 36% (P = 0.021 and hexagonality reduced by 19% (P = 0.007 on day 7. All tissues retained an endothelial cell density higher than the accepted critical level for penetrating keratoplasty. Conclusion: Significant endothelial cell loss was noted while transferring tissues from one medium to another, necessitating the need for reevaluation of transferred tissues before utilization.

  3. Cell therapy of congenital corneal diseases with umbilical mesenchymal stem cells: lumican null mice.

    Directory of Open Access Journals (Sweden)

    Hongshan Liu

    Full Text Available BACKGROUND: Keratoplasty is the most effective treatment for corneal blindness, but suboptimal medical conditions and lack of qualified medical personnel and donated cornea often prevent the performance of corneal transplantation in developing countries. Our study aims to develop alternative treatment regimens for congenital corneal diseases of genetic mutation. METHODOLOGY/PRINCIPAL FINDINGS: Human mesenchymal stem cells isolated from neonatal umbilical cords were transplanted to treat thin and cloudy corneas of lumican null mice. Transplantation of umbilical mesenchymal stem cells significantly improved corneal transparency and increased stromal thickness of lumican null mice, but human umbilical hematopoietic stem cells failed to do the same. Further studies revealed that collagen lamellae were re-organized in corneal stroma of lumican null mice after mesenchymal stem cell transplantation. Transplanted umbilical mesenchymal stem cells survived in the mouse corneal stroma for more than 3 months with little or no graft rejection. In addition, these cells assumed a keratocyte phenotype, e.g., dendritic morphology, quiescence, expression of keratocyte unique keratan sulfated keratocan and lumican, and CD34. Moreover, umbilical mesenchymal stem cell transplantation improved host keratocyte functions, which was verified by enhanced expression of keratocan and aldehyde dehydrogenase class 3A1 in lumican null mice. CONCLUSIONS/SIGNIFICANCE: Umbilical mesenchymal stem cell transplantation is a promising treatment for congenital corneal diseases involving keratocyte dysfunction. Unlike donated corneas, umbilical mesenchymal stem cells are easily isolated, expanded, stored, and can be quickly recovered from liquid nitrogen when a patient is in urgent need.

  4. Removal of the basement membrane enhances corneal wound healing.

    Science.gov (United States)

    Pal-Ghosh, Sonali; Pajoohesh-Ganji, Ahdeah; Tadvalkar, Gauri; Stepp, Mary Ann

    2011-12-01

    Recurrent corneal erosions are painful and put patients' vision at risk. Treatment typically begins with debridement of the area around the erosion site followed by more aggressive treatments. An in vivo mouse model has been developed that reproducibly induces recurrent epithelial erosions in wild-type mice spontaneously within two weeks after a single 1.5 mm corneal debridement wound created using a dulled-blade. This study was conducted to determine whether 1) inhibiting MMP9 function during healing after dulled-blade wounding impacts erosion development and 2) wounds made with a rotating-burr heal without erosions. Oral or topical inhibition of MMPs after dulled-blade wounding does not improve healing. Wounds made by rotating-burr heal with significantly fewer erosions than dulled-blade wounds. The localization of MMP9, β4 integrin and basement membrane proteins (LN332 and type VII collagen), immune cell influx, and reinnervation of the corneal nerves were compared after both wound types. Rotating-burr wounds remove the anterior basement membrane centrally but not at the periphery near the wound margin, induce more apoptosis of corneal stromal cells, and damage more stromal nerve fibers. Despite the fact that rotating-burr wounds do more damage to the cornea, fewer immune cells are recruited and significantly more wounds resolve completely. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Low-dose ultraviolet-B irradiation of donor corneal endothelium and graft survival

    International Nuclear Information System (INIS)

    Dana, M.R.; Olkowski, S.T.; Ahmadian, H.; Stark, W.J.; Young, E.M.

    1990-01-01

    Donor rabbit corneal endothelium was pretreated with different doses of ultraviolet (UV-B) irradiation (302 nm) before grafting to test whether allograft survival could be favorably affected in comparison with untreated corneas grafted into the same recipients. Endothelial rejection was observed in 19 of 32 (59%) eyes that received no treatment compared with five of 32 (16%) eyes that received UV-B (P less than 0.001), and increasing doses of UV-B were associated with lower rejection rates (P less than 0.05). Although exposure of donor endothelium significantly reduced endothelial rejection at all doses tested, it resulted in primary graft failure in a substantial proportion of corneas treated at high doses. Class II (Ia) antigen staining of corneal tissue was present in conjunction with clinical evidence of rejection, and the magnitude of staining correlated with the histologic extent of inflammation. Scanning electron microscopy revealed various endothelial cell surface irregularities and membrane defects in high-dose UV-treated corneas. Endothelial cell cultures exposed in vitro to UV-B light showed a dose-dependent loss in cell viability. These data suggest that UV-B pretreatment of donor corneal endothelium prolongs graft survival but that toxic side effects must be carefully controlled

  6. Breakdown evaluation of corneal epithelial barrier caused by antiallergic eyedrops using an electrophysiologic method.

    Science.gov (United States)

    Nakashima, Mikiro; Nakamura, Tadahiro; Teshima, Mugen; To, Hideto; Uematsu, Masafumi; Kitaoka, Takashi; Taniyama, Kotaro; Nishida, Koyo; Nakamura, Junzo; Sasaki, Hitoshi

    2008-02-01

    The aim of this study was to examine the usefulness of an electrophysiologic method for predicting corneal epithelial breakdown by antiallergic eyedrops and comparing the results with those in other appraisal methods. Six kinds of antiallergic eyedrops, including benzalkonium chloride (BK) as an ophthalmic preservative and two kinds of BK-free antiallergic eyedrops, were used in this study. Eyedrops were applied to excise rabbit corneas and monitoring was performed according to an electrophysiologic method, using a commercially available chamber system to mimic human tear turnover. Changes in transepithelial electrical resistance (TEER) in the corneal surface were recorded. The cytotoxicity of each kind of eyedrops in a normal rabbit corneal epithelial (NRCE) cell line and a human endothelial cell line EA.hy926 was also examined. The extent of decrease in the corneal TEER after applying antiallergic eyedrops was dependent on the concentration of the BK included as a preservative, but it was also affected by the different kinds of drugs when the BK concentration was low. Higher cytotoxicity of the eyedrops against the NRCE and EA.hy926 cell lines was observed with a reduction of TEER. Monitoring changes in the corneal TEER, according to the electrophysiologic method with the application of antiallergic eyedrops, is useful for predicting corneal epithelial breakdown caused by their instillation.

  7. Corneal Toxicity Following Exposure to Asclepias Tuberosa.

    Science.gov (United States)

    Mikkelsen, Lauge Hjorth; Hamoudi, Hassan; Gül, Cigdem Altuntas; Heegaard, Steffen

    2017-01-01

    To present a case of corneal toxicity following exposure to milky plant latex from Asclepias tuberosa. A 70-year-old female presented with blurred vision and pain in her left eye after handling an Ascepias tuberosa . Clinical examination revealed a corneal stromal oedema with small epithelial defects. The corneal endothelium was intact and folds in Descemets membrane were observed. The oedema was treated with chloramphenicol, dexamethasone and scopolamine. The corneal oedema had appeared after corneal exposure to the plant, Asclepias tuberosa , whose latex contains cardenolides that inhibit the Na + / K + -ATPase in the corneal endothelium. The oedema resolved after 96 hours. After nine months the best corrected visual acuity was 20/20. Corneal toxicity has previously been reported for plants of the Asclepias family. This is a rare case describing severe corneal toxicity caused by exposure to latex from Asclepias tuberosa . Handling of plants of the Asclepias family should be kept as a differential diagnosis in cases of acute corneal toxicity.

  8. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  9. Semi-quantitative assessments of dextran toxicity on corneal endothelium: conceptual design of a predictive algorithm.

    Science.gov (United States)

    Filev, Filip; Oezcan, Ceprail; Feuerstacke, Jana; Linke, Stephan J; Wulff, Birgit; Hellwinkel, Olaf J C

    2017-03-01

    Dextran is added to corneal culture medium for at least 8 h prior to transplantation to ensure that the cornea is osmotically dehydrated. It is presumed that dextran has a certain toxic effect on corneal endothelium but the degree and the kinetics of this effect have not been quantified so far. We consider that such data regarding the toxicity of dextran on the corneal endothelium could have an impact on scheduling and logistics of corneal preparation in eye banking. In retrospective statistic analyses, we compared the progress of corneal endothelium (endothelium cell loss per day) of 1334 organ-cultured corneal explants in media with and without dextran. Also, the influence of donor-age, sex and cause of death on the observed dextran-mediated effect on endothelial cell counts was studied. Corneas cultured in dextran-free medium showed a mean endothelium cell count decrease of 0.7% per day. Dextran supplementation led to a mean endothelium cell loss of 2.01% per day; this reflects an increase by the factor of 2.9. The toxic impact of dextran was found to be time dependent; while the prevailing part of the effect was observed within the first 24 h after dextran-addition. Donor age, sex and cause of death did not seem to have an influence on the dextran-mediated toxicity. Based on these findings, we could design an algorithm which approximately describes the kinetics of dextran-toxicity. We reproduced the previously reported toxic effect of dextran on the corneal endothelium in vitro. Additionally, this is the first work that provides an algorithmic instrument for the semi-quantitative calculation of the putative endothelium cell count decrease in dextran containing medium for a given incubation time and could thus influence the time management and planning of corneal transplantations.

  10. [Endothelial keratoplasty: Descemet stripping (DSEK) using TAN EndoGlide™ device: case series].

    Science.gov (United States)

    Pazos, Henrique Santiago Baltar; Pazos, Paula Fernanda Morais Ramalho Baltar; Nogueira Filho, Pedro Antônio; Grisolia, Ana Beatriz Diniz; Silva, André Berger Emiliano; Gomes, José Álvaro Pereira

    2011-01-01

    To report the results of Descemet stripping endothelial keratoplasty (DSEK) using the TAN EndoGlideTM device to facilitate the insertion of the endothelial membrane. Prospective clinical study that included nine patients presenting corneal edema secondary to endothelial dysfunction. Best corrected visual acuity, refraction, central corneal thickness, endothelial cell density and complications were analyzed after a six-month follow-up. There was a significant improvement in the corneal edema and visual acuity in 7 patients (77.78%). The best corrected visual acuity ranged between 20/40 and 20/200. The average density of endothelial cells in six months varied between 1,305 cells/mm² and 2,346 cells/mm² with an average loss of 33.14% cells. Detachment of part of the graft was observed in one eye (11.11%) and primary failure of the endothelial transplantation occurred in 2 eyes (22.22%). The device TAN EndoGlideTM facilitates the introduction of the graft in Descemet stripping endothelial keratoplasty.

  11. NK cells modulate the inflammatory response to corneal epithelial abrasion and thereby support wound healing

    Science.gov (United States)

    Natural killer cells are lymphocytes of the innate immune system that have crucial cytotoxic and regulatory roles in adaptive immunity and inflammation. Herein, we consider a role for these cells in corneal wound healing. After a 2-mm central epithelial abrasion of the mouse cornea, a subset of clas...

  12. The high-risk corneal regraft model: a justification for tissue matching in humans

    Czech Academy of Sciences Publication Activity Database

    Vitova, A.; Kuffova, L.; Klaska, I.; Holáň, Vladimír; Cornall, R.J.; Forrester, J.V.

    2013-01-01

    Roč. 26, č. 4 (2013), s. 453-461 ISSN 0934-0874 Institutional support: RVO:68378050 Keywords : accelerated rejection * corneal transplantation * dendritic cell s * regraft * T- cell memory * transgenic mouse Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.120, year: 2013

  13. Structural, Morphological, and Functional Correlates of Corneal Endothelial Toxicity Following Corneal Exposure to Sulfur Mustard Vapor

    Science.gov (United States)

    2013-10-01

    States Depart- ment of Agriculture certificate No. 51-F-0006). All procedures were in compliance with the ARVO Statement for the Use of Animals in...exposure: pathological mechanism and poten- tial therapy. Toxicology. 2009;263:59–69. 9. Gordon MK, Desantis A, Deshmukh M, et al. Doxycycline hydrogels

  14. Analysis of central corneal thickness in different degrees of diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Shan Hua

    2014-06-01

    Full Text Available AIM: To study central corneal thickness(CCTand correlation in different degrees of diabetic retinopathy(DR.METHODS: A total of 65 cases(130 eyeswith different degrees of DR and 35 normal cases(70 eyesas the age-and gender-matched control group were examined by corneal endothelial microscope, to measure CCT and statistics RESULTS: Compared to control group, there were no significant difference of CCT both mild and medium nonproliferative diabetic retinopathy(NPDRgroups(P>0.05. While the CCT of severe NPDR group and proliferative diabetic retinopathy(PDRgroup were thicker than control group, and the differences were statistically significant(PPPr=0.173, PCONCLUSION: The CCT increases with severity of DR. Taking care of protecting corneal endothelium is very important in the time of therapeutic measure, especially intraocular operation, to decrease complication.

  15. Latest progress of BIGH3 gene in corneal diseases and diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Fan-Qian Song

    2017-03-01

    Full Text Available BIGH3 gene plays an important role in ocular diseases. On the one hand, it is closely related to the occurrence of corneal diseases. BIGH3 gene can inhibit corneal neovascularization, lead to corneal dystrophy, participate in keratoconus formation. On the other hand, it can lead to the formation of neovascularization in diabetic retinopathy. The latest experiments show that TGF beta secreted by macrophages can promote the expression of BIGH3 mRNA and BIGH3 protein, and promote apoptosis of retinal endothelial cells and pericytes, which leads to the formation of neovascularization in diabetic retinopathy. This article will describe the new progress of BIGH3 gene in ocular diseases from several aspects as mentioned above.

  16. Late onset of a persistent, deep stromal scarring after PRK and corneal cross-linking in a patient with forme fruste keratoconus.

    Science.gov (United States)

    Güell, Jose L; Verdaguer, Paula; Elies, Daniel; Gris, Oscar; Manero, Felicidad

    2014-04-01

    To present a case of a late, deep stromal scar in a 22-year-old patient with forme fruste keratoconus who underwent combined corneal cross-linking and photorefractive keratectomy (PRK). Topography-guided corneal cross-linking combined with corneal PRK (without complications) was performed in both eyes with a delay of 2 weeks between each eye. At the 5-month postoperative examination of the right eye, a localized corneal haze was circumscribed to the posterior deep stroma, signifying a decrease of visual acuity. However, this improved partially and temporarily when treated with topical corticoids during 2 years of follow-up and then reoccurred, affecting the corrected distance visual acuity. To the authors' knowledge, this is the first documented, clinical case presenting a deep stromal affectation without endothelial decompensation and visual acuity affectation as a postoperative complication following topography-guided PRK and corneal cross-linking. Copyright 2014, SLACK Incorporated.

  17. Recovery of Corneal Sensitivity and Increase in Nerve Density and Wound Healing in Diabetic Mice After PEDF Plus DHA Treatment.

    Science.gov (United States)

    He, Jiucheng; Pham, Thang Luong; Kakazu, Azucena; Bazan, Haydee E P

    2017-09-01

    Diabetic keratopathy decreases corneal sensation and tear secretion and delays wound healing after injury. In the current study, we tested the effect of treatment with pigment epithelium-derived factor (PEDF) in combination with docosahexaenoic acid (DHA) on corneal nerve regeneration in a mouse model of diabetes with or without corneal injury. The study was performed in streptozotocin-induced diabetic mice (C57BL/6). Ten weeks after streptozotocin injection, diabetic mice showed significant decreases of corneal sensitivity, tear production, and epithelial subbasal nerve density when compared with age-matched normal mice. After diabetic mice were wounded in the right eye and treated in both eyes with PEDF+DHA for 2 weeks, there was a significant increase in corneal epithelial nerve regeneration and substance P-positive nerve density in both wounded and unwounded eyes compared with vehicle-treated corneas. There also was elevated corneal sensitivity and tear production in the treated corneas compared with vehicle. In addition, PEDF+DHA accelerated corneal wound healing, selectively recruited type 2 macrophages, and prevented neutrophil infiltration in diabetic wounded corneas. These results suggest that topical treatment with PEDF+DHA promotes corneal nerve regeneration and wound healing in diabetic mice and could potentially be exploited as a therapeutic option for the treatment of diabetic keratopathy. © 2017 by the American Diabetes Association.

  18. Corneal Toxicity Following Exposure to Asclepias Tuberosa

    DEFF Research Database (Denmark)

    Mikkelsen, Lauge Hjorth; Hamoudi, Hassan; Gül, Cigdem Altuntas

    2017-01-01

    PURPOSE: To present a case of corneal toxicity following exposure to milky plant latex from Asclepias tuberosa. METHODS: A 70-year-old female presented with blurred vision and pain in her left eye after handling an Ascepias tuberosa. Clinical examination revealed a corneal stromal oedema with small...... epithelial defects. The corneal endothelium was intact and folds in Descemets membrane were observed. The oedema was treated with chloramphenicol, dexamethasone and scopolamine. RESULTS: The corneal oedema had appeared after corneal exposure to the plant, Asclepias tuberosa, whose latex contains cardenolides...... that inhibit the Na+/ K+-ATPase in the corneal endothelium. The oedema resolved after 96 hours. After nine months the best corrected visual acuity was 20/20. CONCLUSION: Corneal toxicity has previously been reported for plants of the Asclepias family. This is a rare case describing severe corneal toxicity...

  19. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

    Science.gov (United States)

    Dupont-Monod, Sylvère; Labbé, Antoine; Fayol, Nicolas; Chassignol, Alexis; Bourges, Jean-Louis; Baudouin, Christophe

    2009-03-01

    To use anterior segment optical coherence tomography (AS-OCT) to analyze the in vivo architecture of clear corneal incisions after phacoemulsification using different techniques. Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, Paris, France. This prospective observational study analyzed clear corneal incisions used in phacoemulsification. All wounds were evaluated 1 day and 8 days postoperatively by AS-OCT (Visante). Incision architecture and pachymetry at the wound level were analyzed. Thirty-five clear corneal incisions were analyzed. Six eyes had 2.75 mm coaxial phacoemulsification, 19 had 2.20 mm microincision coaxial phacoemulsification, and 10 had 1.30 mm bimanual microincision phacoemulsification. The 1.30 mm incision had a straight-line configuration. The 2.20 mm and 2.75 mm incisions had an arcuate configuration. The angles of incidence of 1.30 mm incisions were greater than those of 2.20 mm incisions (P<.001). All incisions had slight corneal edema limited to the incision area. The edema was slightly greater around 1.30 mm incisions (mean pachymetry 1143 microm +/- 140 [SD]) than around 2.20 mm incisions (mean 1012 +/- 101 microm) (P = .001). Bimanual procedures had satisfactory endothelial apposition in the enlarged areas, where stromal edema was less than that surrounding the unenlarged 1.30 mm incisions. The 3 phacoemulsification techniques induced gaping of the endothelial edge, minor inadequate endothelial apposition, and mild stromal edema in the area of the clear corneal incisions. Bimanual microincision sleeveless phacoemulsification may alter the wound slightly more than coaxial 2.75 mm and microcoaxial 2.20 mm sleeved-tip phacoemulsification.

  20. Correction of low corneal astigmatism in cataract surgery

    Directory of Open Access Journals (Sweden)

    Pia Leon

    2015-08-01

    Full Text Available AIM: To evaluate and compare aspheric toric intraocular lens (IOL implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI to manage low corneal astigmatism (1.0-2.0 D in cataract surgery.METHODS:A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were:visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan. Follow-up lasted 6mo.RESULTS: The mean uncorrected distance visual acuity (UCVA and the best corrected visual acuity (BCVA demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01. No difference was observed in the postoperative endothelial cell count between the two groups.CONCLUSION: The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.

  1. Efficient and safe gene delivery to human corneal endothelium using magnetic nanoparticles.

    Science.gov (United States)

    Czugala, Marta; Mykhaylyk, Olga; Böhler, Philip; Onderka, Jasmine; Stork, Björn; Wesselborg, Sebastian; Kruse, Friedrich E; Plank, Christian; Singer, Bernhard B; Fuchsluger, Thomas A

    2016-07-01

    To develop a safe and efficient method for targeted, anti-apoptotic gene therapy of corneal endothelial cells (CECs). Magnetofection (MF), a combination of lipofection with magnetic nanoparticles (MNPs; PEI-Mag2, SO-Mag5, PalD1-Mag1), was tested in human CECs and in explanted human corneas. Effects on cell viability and function were investigated. Immunocompatibility was assessed in human peripheral blood mononuclear cells. Silica iron-oxide MNPs (SO-Mag5) combined with X-tremeGENE-HP achieved high transfection efficiency in human CECs and explanted human corneas, without altering cell viability or function. Magnetofection caused no immunomodulatory effects in human peripheral blood mononuclear cells. Magnetofection with anti-apoptotic P35 gene effectively blocked apoptosis in CECs. Magnetofection is a promising tool for gene therapy of corneal endothelial cells with potential for targeted on-site delivery.

  2. Corneal Toxicity Following Exposure to Asclepias Tuberosa

    OpenAIRE

    Mikkelsen, Lauge Hjorth; Hamoudi, Hassan; G?l, Cigdem Altuntas; Heegaard, Steffen

    2017-01-01

    PURPOSE: To present a case of corneal toxicity following exposure to milky plant latex from Asclepias tuberosa.METHODS: A 70-year-old female presented with blurred vision and pain in her left eye after handling an Ascepias tuberosa. Clinical examination revealed a corneal stromal oedema with small epithelial defects. The corneal endothelium was intact and folds in Descemets membrane were observed. The oedema was treated with chloramphenicol, dexamethasone and scopolamine.RESULTS: The corneal ...

  3. Inverse cutting of posterior lamellar corneal grafts by a femtosecond laser.

    Science.gov (United States)

    Hjortdal, Jesper; Nielsen, Esben; Vestergaard, Anders; Søndergaard, Anders

    2012-01-01

    Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft thickness towards the periphery in every graft. The purpose of this study was to evaluate if posterior lamellar grafts can be prepared from the endothelial side by a femto-second laser, resulting in reproducible, thin grafts of even thickness. A CZM 500 kHz Visumax femto-second laser was used. Organ cultured donor grafts were mounted in an artifical anterior chamber with the endothelial side up and out. Posterior grafts of 7.8 mm diameter and 130 micron thickness were prepared by femto-second laser cutting. A standard DSAEK procedure was performed in 10 patients with Fuchs endothelial dystrophy. Patients were followed-up regularly and evaluated by measurement of complications, visual acuity, corneal thickness (Pentacam HR), and endothelial cell density. Femto-laser cutting of grafts and surgery was uncomplicated. Rebubbling was necessary in 5 of 10 cases (normally only in 1 of 20 cases). All grafts were attached and cleared up during the first few weeks. After six months, the average visual acuity was 0.30 (range: 0.16 to 0.50), corneal thickness was 0.58 mm (range 0.51 to 0.63), and endothelial cell density was 1.570 per sq. mm (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months with satisfying endothelial cell counts. Poor visual acuity caused by interface scatter was observed in most patients. Femto-second laser cutting parameters needs to be optimised to

  4. Comparative Confocal and Histopathological Study of Corneal Changes in Multiple Myeloma.

    Science.gov (United States)

    Micali, Antonio; Roszkowska, Anna M; Postorino, Elisa I; Rania, Laura; Aragona, Emanuela; Wylegala, Edward; Nowinska, Anna; Ieni, Antonio; Calimeri, Sebastiano; Pisani, Antonina; Aragona, Pasquale; Puzzolo, Domenico

    2017-01-01

    Corneal opacities rarely occur in multiple myeloma (MM). Our study correlates the findings of in vivo confocal microscopy (IVCM), a useful diagnostic tool, with histopathological features of corneal opacities appearing in a patient with MM. Case report. A 53-year-old man developed corneal opacities in both eyes, more pronounced in the left eye. After IVCM examination, he underwent penetrating keratoplasty in the left eye, and the button was processed for light and electron microscopy and immunohistochemistry. The diagnosis of MM was made, as confirmed by the elevation of IgGk light chains. IVCM demonstrated hyperreflective areas at the epithelial level, hyperreflective keratocytes of dendritic and lamellar morphology in whole stroma, and hyperreflective endothelial cells. Histopathological examination disclosed many vacuoles in the epithelial cell cytoplasm and a homogenous granular material in the Bowman layer. In stroma, keratocytes of different shape and size, with vesicles laden with an abnormal material, were evident. In Descemet membrane, the posterior nonbanded zone had a honeycomb appearance because of the presence of many roundish spaces among wide-spaced collagen fibers. Endothelial cells demonstrated vesicles filled with a material of uneven electron density. Immunohistochemical analysis showed strong positivity for IgGk light chains in keratocytes and among stromal lamellae. This is the first study describing a correspondence between IVCM features and histopathological alterations observed in corneal opacities in MM. The results of this study improve the current understanding of the pictures obtained by IVCM studies.

  5. Comparison of the effects of intraocular irrigating solutions on the corneal endothelium in intraocular lens implantation.

    Science.gov (United States)

    Matsuda, M; Kinoshita, S; Ohashi, Y; Shimomura, Y; Ohguro, N; Okamoto, H; Omoto, T; Hosotani, H; Yoshida, H

    1991-01-01

    We conducted a randomised prospective controlled study to determine the effects of a glucose glutathione bicarbonate solution (BSS Plus) and a citrate acetate bicarbonate solution (S-MA2) on the corneal endothelium in patients undergoing extracapsular cataract extraction with posterior chamber lens implantation. One eye of each patient was randomly assigned to receive BSS Plus, and the other eye to receive S-MA2. BSS Plus caused significantly less corneal swelling on the first postoperative day than did S-MA2. There was no difference between the two solutions in their effect on corneal thickness one week and one month postoperatively. Computer assisted morphometric analysis of wide-field specular microscopic photographs demonstrated minimal changes in endothelial morphological characteristics in the eyes irrigated with BSS Plus. By comparison S-MA2, caused a significant loss of endothelial cells and a marked reduction in the figure coefficient. These results indicated that BSS Plus has a clinical advantage over S-MA2 with respect to the corneal endothelium. PMID:1873266

  6. Progress of research on corneal collagen cross-linking for corneal melting

    Directory of Open Access Journals (Sweden)

    Ke-Ren Xiao

    2016-06-01

    Full Text Available Corneal collagen cross-linking(CXLcould increase the mechanical strength, biological stability and halt ectasia progression due to covalent bond formed by photochemical reaction between ultraviolet-A and emulsion of riboflavin between collagen fibers in corneal stroma. Corneal melting is an autoimmune related noninfectious corneal ulcer. The mechanism of corneal melting, major treatment, the basic fundamental of ultraviolet-A riboflavin induced CXL and the clinical researches status and experiment in CXL were summarized in the study.

  7. Minocycline inhibits alkali burn-induced corneal neovascularization in mice.

    Directory of Open Access Journals (Sweden)

    Ou Xiao

    Full Text Available The purpose of this study was to investigate the effects of minocycline on alkali burn-induced corneal neovascularization (CNV. A total of 105 mice treated with alkali burns were randomly divided into three groups to receive intraperitoneal injections of either phosphate buffered saline (PBS or minocycline twice a day (60 mg/kg or 30 mg/kg for 14 consecutive days. The area of CNV and corneal epithelial defects was measured on day 4, 7, 10, and14 after alkali burns. On day 14, a histopathological examination was performed to assess morphological change and the infiltration of polymorphonuclear neutrophils (PMNs. The mRNA expression levels of vascular endothelial growth factor (VEGF and its receptors (VEGFRs, basic fibroblast growth factor (bFGF, matrix metalloproteinases (MMPs, interleukin-1α, 1β, 6 (IL-1α, IL-1β, IL-6 were analyzed using real-time quantitative polymerase chain reaction. The expression of MMP-2 and MMP-9 proteins was determined by gelatin zymography. In addition, enzyme-linked immunosorbent assay was used to analyze the protein levels of VEGFR1, VEGFR2, IL-1β and IL-6. Minocycline at a dose of 60 mg/kg or 30 mg/kg significantly enhanced the recovery of the corneal epithelial defects more than PBS did. There were significant decreases of corneal neovascularization in the group of high-dosage minocycline compared with the control group at all checkpoints. On day 14, the infiltrated PMNs was reduced, and the mRNA expression of VEGFR1, VEGFR2, bFGF, IL-1β, IL-6, MMP-2, MMP-9, -13 as well as the protein expression of VEGFR2, MMP-2, -9, IL-1β, IL-6 in the corneas were down-regulated with the use of 60 mg/kg minocycline twice a day. Our results showed that the intraperitoneal injection of minocycline (60 mg/kg b.i.d. can significantly inhibit alkali burn-induced corneal neovascularization in mice, possibly by accelerating corneal wound healing and by reducing the production of angiogenic factors, inflammatory cytokines and MMPs.

  8. Topical Drug Formulations for Prolonged Corneal Anesthesia

    Science.gov (United States)

    Wang, Liqiang; Shankarappa, Sahadev A.; Tong, Rong; Ciolino, Joseph B.; Tsui, Jonathan H.; Chiang, Homer H.; Kohane, Daniel S.

    2013-01-01

    Purpose Ocular local anesthetics (OLA’s) currently used in routine clinical practice for corneal anesthesia are short acting and their ability to delay corneal healing makes them unsuitable for long-term use. In this study, we examined the effect on the duration of corneal anesthesia of the site-1 sodium channel blocker tetrodotoxin (TTX), applied with either proparacaine or the chemical permeation enhancer OTAB. The effect of test solutions on corneal healing was also studied. Methods Solutions of TTX, proparacaine, and OTAB, singly or in combination were applied topically to the rat cornea. The blink response, an indirect measure of corneal sensitivity, was recorded using a Cochet-Bonnet esthesiometer, and the duration of corneal anesthesia calculated. The effect of test compounds on the rate of corneal epithelialization was studied in vivo following corneal debridement. Results Combination of TTX and proparacaine resulted in corneal anesthesia that was 8–10 times longer in duration than that from either drug administered alone, while OTAB did not prolong anesthesia. The rate of corneal healing was moderately delayed following co-administration of TTX and proparacaine. Conclusion Co-administration of TTX and proparacaine significantly prolonged corneal anesthesia but in view of delayed corneal re-epithelialization, caution is suggested in use of the combination. PMID:23615270

  9. Prolonging survival of corneal transplantation by selective sphingosine-1-phosphate receptor 1 agonist.

    Directory of Open Access Journals (Sweden)

    Min Gao

    Full Text Available Corneal transplantation is the most used therapy for eye disorders. Although the cornea is somewhat an immune privileged organ, immune rejection is still the major problem that reduces the success rate. Therefore, effective chemical drugs that regulate immunoreactions are needed to improve the outcome of corneal transplantations. Here, a sphingosine-1-phosphate receptor 1 (S1P1 selective agonist was systematically evaluated in mouse allogeneic corneal transplantation and compared with the commonly used immunosuppressive agents. Compared with CsA and the non-selective sphingosine 1-phosphate (S1P receptor agonist FTY720, the S1P1 selective agonist can prolong the survival corneal transplantation for more than 30 days with a low immune response. More importantly, the optimal dose of the S1P1 selective agonist was much less than non-selective S1P receptor agonist FTY720, which would reduce the dose-dependent toxicity in drug application. Then we analyzed the mechanisms of the selected S1P1 selective agonist on the immunosuppression. The results shown that the S1P1 selective agonist could regulate the distribution of the immune cells with less CD4+ T cells and enhanced Treg cells in the allograft, moreover the expression of anti-inflammatory cytokines TGF-β1 and IL-10 unregulated which can reduce the immunoreactions. These findings suggest that S1P1 selective agonist may be a more appropriate immunosuppressive compound to effectively prolong mouse allogeneic corneal grafts survival.

  10. Acute corneal hydrops in keratoconus

    Directory of Open Access Journals (Sweden)

    Prafulla K Maharana

    2013-01-01

    Full Text Available Acute corneal hydrops is a condition characterized by stromal edema due to leakage of aqueous through a tear in descemet membrane. The patient presents with sudden onset decrease in vision, photophobia, and pain. Corneal thinning and ectasias combined with trivial trauma to the eye mostly by eye rubbing is considered as the underlying cause. With conservative approach self-resolution takes around 2 to 3 months. Surgical intervention is required in cases of non-resolution of corneal edema to avoid complications and for early visual rehabilitation. Intracameral injection of air or gas such as perflouropropane is the most common surgical procedure done. Recent investigative modality such as anterior segment optical coherence tomography is an extremely useful tool for diagnosis, surgical planning, and postoperative follow up. Resolution of hydrops may improve the contact lens tolerance and visual acuity but most cases require keratoplasty for visual rehabilitation.

  11. Ocular dimensions, corneal thickness, and corneal curvature in quarter horses with hereditary equine regional dermal asthenia.

    Science.gov (United States)

    Badial, Peres R; Cisneros-Àlvarez, Luis Emiliano; Brandão, Cláudia Valéria S; Ranzani, José Joaquim T; Tomaz, Mayana A R V; Machado, Vania M; Borges, Alexandre S

    2015-09-01

    The aim of this study was to compare ocular dimensions, corneal curvature, and corneal thickness between horses affected with hereditary equine regional dermal asthenia (HERDA) and unaffected horses. Five HERDA-affected quarter horses and five healthy control quarter horses were used. Schirmer's tear test, tonometry, and corneal diameter measurements were performed in both eyes of all horses prior to ophthalmologic examinations. Ultrasonic pachymetry was performed to measure the central, temporal, nasal, dorsal, and ventral corneal thicknesses in all horses. B-mode ultrasound scanning was performed on both eyes of each horse to determine the dimensions of the ocular structures and to calculate the corneal curvature. Each corneal region examined in this study was thinner in the affected group compared with the healthy control group. However, significant differences in corneal thickness were only observed for the central and dorsal regions. HERDA-affected horses exhibited significant increases in corneal curvature and corneal diameter compared with unaffected animals. The ophthalmologic examinations revealed mild corneal opacity in one eye of one affected horse and in both eyes of three affected horses. No significant between-group differences were observed for Schirmer's tear test, intraocular pressure, or ocular dimensions. Hereditary equine regional dermal asthenia-affected horses exhibit decreased corneal thickness in several regions of the cornea, increased corneal curvature, increased corneal diameter, and mild corneal opacity. Additional research is required to determine whether the increased corneal curvature significantly impacts the visual accuracy of horses with HERDA. © 2014 American College of Veterinary Ophthalmologists.

  12. Corneal manifestations in systemic diseases

    OpenAIRE

    Zarranz-Ventura, J.; Nova, E. De; Moreno-Montañés, J.

    2008-01-01

    Un gran número de enfermedades sistémicas presentan manifestaciones corneales dentro de su espectro de enfermedad. El estudio detallado de todos los cuadros que asocian patología corneal resulta inabarcable, por ello se presentan las enfermedades más prevalentes o características. Este estudio contempla las enfermedades pulmonares y conectivopatías (colagenosis, enfermedades reumatológicas y enfermedades inflamatorias idiopáticas), las enfermedades dermatológicas, cardiovasculares, hematológi...

  13. [Corneal manifestations in systemic diseases].

    Science.gov (United States)

    Zarranz Ventura, J; De Nova, E; Moreno-Montañés, J

    2008-01-01

    Systemic diseases affecting the cornea have a wide range of manifestations. The detailed study of all pathologies that cause corneal alteration is unapproachable, so we have centered our interest in the most prevalent or characteristic of them. In this paper we have divided these pathologies in sections to facilitate their study. Pulmonar and conective tissue (like colagen, rheumatologic and idiopathic inflamatory diseases), dermatologic, cardiovascular, hematologic, digestive and hepatopancreatic diseases with corneal alteration are described. Endocrine and metabolic diseases, malnutrition and carential states are also studied, as well as some otorhinolaryngologic and genetic diseases that affect the cornea. Finally, a brief report of ocular toxicity induced by drugs is referred.

  14. Correlations between corneal and total wavefront aberrations

    Science.gov (United States)

    Mrochen, Michael; Jankov, Mirko; Bueeler, Michael; Seiler, Theo

    2002-06-01

    Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p the corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p equals 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.

  15. Image-guided modified deep anterior lamellar keratoplasty (DALK) corneal transplant using intraoperative optical coherence tomography

    Science.gov (United States)

    Tao, Yuankai K.; LaBarbera, Michael; Ehlers, Justis P.; Srivastava, Sunil K.; Dupps, William J.

    2015-03-01

    Deep anterior lamellar keratoplasty (DALK) is an alternative to full-thickness corneal transplant and has advantages including the absence of allograft rejection; shortened duration of topical corticosteroid treatment and reduced associated risk of glaucoma, cataract, or infection; and enables use of grafts with poor endothelial quality. DALK begins by performing a trephination of approximately 80% stromal thickness, as measured by pachymetry. After removal of the anterior stoma, a needle is inserted into the residual stroma to inject air or viscoelastic to dissect Descemet's membrane. These procedures are inherently difficult and intraoperative rates of Descemet's membrane perforation between 4-39% have been reported. Optical coherence tomography (OCT) provides high-resolution images of tissue microstructures in the cornea, including Descemet's membrane, and allows quantitation of corneal layer thicknesses. Here, we use crosssectional intraoperative OCT (iOCT) measurements of corneal thickness during surgery and a novel micrometeradjustable biopsy punch to precision-cut the stroma down to Descemet's membrane. Our prototype cutting tool allows us to establish a dissection plane at the corneal endothelium interface, mitigates variability in cut-depths as a result of tremor, reduces procedure complexity, and reduces complication rates. iOCT-guided modified DALK procedures were performed on 47 cadaveric porcine eyes by non-experts and achieved a perforation rate of ~5% with a mean corneal dissection time care.

  16. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction.

    Science.gov (United States)

    Garzón, Nuria; Poyales, Francisco; Illarramendi, Igor; Mendicute, Javier; Jáñez, Óscar; Caro, Pedro; López, Alfredo; Argüeso, Francisco

    2017-12-01

    To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p  0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.

  17. Corneal Regeneration After Photorefractive Keratectomy: A Review

    Directory of Open Access Journals (Sweden)

    Javier Tomás-Juan

    2015-07-01

    Full Text Available Photorefractive keratectomy (PRK remodels corneal stroma to compensate refractive errors. The removal of epithelium and the ablation of stroma provoke the disruption of corneal nerves and a release of several peptides from tears, epithelium, stroma and nerves. A myriad of cytokines, growth factors, and matrix metalloproteases participate in the process of corneal wound healing. Their balance will determine if reepithelization and stromal remodeling are appropriate. The final aim is to achieve corneal transparency for restoring corneal function, and a proper visual quality. Therefore, wound-healing response is critical for a successful refractive surgery. Our goal is to provide an overview into how corneal wounding develops following PRK. We will also review the influence of intraoperative application of mitomycin C, bandage contact lenses, anti-inflammatory and other drugs in preventing corneal haze and post-PRK pain.

  18. History of corneal transplantation in Australia.

    Science.gov (United States)

    Coster, Douglas J

    2015-04-01

    Corneal transplantation is a triumph of modern ophthalmology. The possibility of corneal transplantation was first raised in 1797 but a century passed before Zirm achieved the first successful penetrating graft in 1905. Gibson reported the first corneal graft in Australia from Brisbane in 1940 and English established the first eye bank there a few years later. Corneal transplantation evolved steadily over the twentieth century. In the second half of the century, developments in microsurgery, including surgical materials such as monofilament nylon and strong topical steroid drops, accounted for improvements in outcomes. In 2013, approximately 1500 corneal transplants were done in Australia. Eye banking has evolved to cope with the rising demands for donor corneas. Australian corneal surgeons collaborated to establish and support the Australian Corneal Graft Registry in 1985. It follows the outcomes of their surgery and has become an important international resource for surgeons seeking further improvement with the procedure. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  19. Corneal Regeneration After Photorefractive Keratectomy: A Review.

    Science.gov (United States)

    Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane; Hanneken, Ludger

    2015-01-01

    Photorefractive keratectomy (PRK) remodels corneal stroma to compensate refractive errors. The removal of epithelium and the ablation of stroma provoke the disruption of corneal nerves and a release of several peptides from tears, epithelium, stroma and nerves. A myriad of cytokines, growth factors, and matrix metalloproteases participate in the process of corneal wound healing. Their balance will determine if reepithelization and stromal remodeling are appropriate. The final aim is to achieve corneal transparency for restoring corneal function, and a proper visual quality. Therefore, wound-healing response is critical for a successful refractive surgery. Our goal is to provide an overview into how corneal wounding develops following PRK. We will also review the influence of intraoperative application of mitomycin C, bandage contact lenses, anti-inflammatory and other drugs in preventing corneal haze and post-PRK pain. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  20. Corneal collagen crosslinking and pigment dispersion syndrome.

    Science.gov (United States)

    LaHood, Benjamin R; Moore, Sacha

    2017-03-01

    We describe the case of a keratoconus patient with pigment dispersion syndrome (PDS) who was treated for progressive corneal ectasia with corneal collagen crosslinking (CXL). Pigment dispersion syndrome has been shown to have associated morphologic changes of the corneal endothelium. Corneal CXL has the potential to cause toxicity to the corneal endothelium, and adjacent pigment might increase the likelihood of damage. In this case, the presence of PDS had no detrimental effect on the outcome of treatment, and no complications were observed at 12 months follow-up, indicating that it may be safe to perform corneal CXL in the setting of PDS. This is an important observation as the number of indications for corneal CXL grows. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Corneal stroma microfibrils.

    Science.gov (United States)

    Hanlon, Samuel D; Behzad, Ali R; Sakai, Lynn Y; Burns, Alan R

    2015-03-01

    Elastic tissue was first described well over a hundred years ago and has since been identified in nearly every part of the body. In this review, we examine elastic tissue in the corneal stroma with some mention of other ocular structures which have been more thoroughly described in the past. True elastic fibers consist of an elastin core surrounded by fibrillin microfibrils. However, the presence of elastin fibers is not a requirement and some elastic tissue is comprised of non-elastin-containing bundles of microfibrils. Fibers containing a higher relative amount of elastin are associated with greater elasticity and those without elastin, with structural support. Recently it has been shown that the microfibrils, not only serve mechanical roles, but are also involved in cell signaling through force transduction and the release of TGF-β. A well characterized example of elastin-free microfibril bundles (EFMBs) is found in the ciliary zonules which suspend the crystalline lens in the eye. Through contraction of the ciliary muscle they exert enough force to reshape the lens and thereby change its focal point. It is believed that the molecules comprising these fibers do not turn-over and yet retain their tensile strength for the life of the animal. The mechanical properties of the cornea (strength, elasticity, resiliency) would suggest that EFMBs are present there as well. However, many authors have reported that, although present during embryonic and early postnatal development, EFMBs are generally not present in adults. Serial-block-face imaging with a scanning electron microscope enabled 3D reconstruction of elements in murine corneas. Among these elements were found fibers that formed an extensive network throughout the cornea. In single sections these fibers appeared as electron dense patches. Transmission electron microscopy provided additional detail of these patches and showed them to be composed of fibrils (∼10 nm diameter). Immunogold evidence clearly

  2. Corneal stroma microfibrils

    KAUST Repository

    Hanlon, Samuel D.

    2015-03-01

    Elastic tissue was first described well over a hundred years ago and has since been identified in nearly every part of the body. In this review, we examine elastic tissue in the corneal stroma with some mention of other ocular structures which have been more thoroughly described in the past. True elastic fibers consist of an elastin core surrounded by fibrillin microfibrils. However, the presence of elastin fibers is not a requirement and some elastic tissue is comprised of non-elastin-containing bundles of microfibrils. Fibers containing a higher relative amount of elastin are associated with greater elasticity and those without elastin, with structural support. Recently it has been shown that the microfibrils, not only serve mechanical roles, but are also involved in cell signaling through force transduction and the release of TGF-β. A well characterized example of elastin-free microfibril bundles (EFMBs) is found in the ciliary zonules which suspend the crystalline lens in the eye. Through contraction of the ciliary muscle they exert enough force to reshape the lens and thereby change its focal point. It is believed that the molecules comprising these fibers do not turn-over and yet retain their tensile strength for the life of the animal. The mechanical properties of the cornea (strength, elasticity, resiliency) would suggest that EFMBs are present there as well. However, many authors have reported that, although present during embryonic and early postnatal development, EFMBs are generally not present in adults. Serial-block-face imaging with a scanning electron microscope enabled 3D reconstruction of elements in murine corneas. Among these elements were found fibers that formed an extensive network throughout the cornea. In single sections these fibers appeared as electron dense patches. Transmission electron microscopy provided additional detail of these patches and showed them to be composed of fibrils (~10nm diameter). Immunogold evidence clearly

  3. Changes in corneal topography and biomechanical properties after collagen cross linking for keratoconus: 1-year results.

    Science.gov (United States)

    Sedaghat, Mohammadreza; Bagheri, Mansooreh; Ghavami, Shahri; Bamdad, Shahram

    2015-01-01

    To evaluate changes in corneal topography and biomechanical properties after collagen cross-linking (CXL) for progressive keratoconus. Collagen cross-linking was performed on 97 eyes. We assessed uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA). Corneal topography indices were evaluated using placido disc topography, scanning slit anterior topography (Orbscan II), and rotating Scheimpflug topography (Pentacam). Specular microscopy and corneal biomechanics were evaluated. A 1-year-follow-up results revealed that UCVA improved from 0.31 to 0.45 and BCVA changed from 0.78 to 0.84 (P < 0.001). The mean of average keratometry value decreased from 49.62 to 47.95 D (P < 0.001). Astigmatism decreased from 4.84 to 4.24 D (P < 0.001). Apex corneal thickness decreased from 458.11 to 444.46 μm. Corneal volume decreased from 56.66 to 55.97 mm(3) (P < 0.001). Posterior best fit sphere increased from 55.50 to 46.03 mm (P = 0.025). Posterior elevation increased from 99.2 to 112.22 μm (P < 0.001). Average progressive index increased from 2.26 to 2.56 (P < 0.001). A nonsignificant decrease was observed in mean endothelial count from 2996 to 2928 cell/mm(2) (P = 0.190). Endothelial coefficient of variation (CV) increased nonsignificantly from 18.26 to 20.29 (P = 0.112). Corneal hysteresis changed from 8.18 to 8.36 (P = 0.552) and corneal resistance factor increased from 6.98 to 7.21 (P = 0.202), so these changes were not significant. Visual acuity and K values improved after CXL. In spite of the nonsignificant increase in endothelial cell count and increase in the CV, CLX seems to be a safe treatment for keratoconus. Further studies with larger sample sizes and longer follow-up periods are recommended.

  4. Management of corneal bee sting

    Directory of Open Access Journals (Sweden)

    Razmjoo H

    2011-12-01

    Full Text Available Hassan Razmjoo1,2, Mohammad-Ali Abtahi1,2,4, Peyman Roomizadeh1,3, Zahra Mohammadi1,2, Seyed-Hossein Abtahi1,3,41Medical School, Isfahan University of Medical Sciences (IUMS; 2Ophthalmology Ward, Feiz Hospital, IUMS; 3Isfahan Medical Students Research Center (IMSRC, IUMS; 4Isfahan Ophthalmology Research Center (IORC, Feiz Hospital, IUMS, Isfahan, IranAbstract: Corneal bee sting is an uncommon environmental eye injury that can result in various ocular complications with an etiology of penetrating, immunologic, and toxic effects of the stinger and its injected venom. In this study we present our experience in the management of a middle-aged male with a right-sided deep corneal bee sting. On arrival, the patient was complaining of severe pain, blurry vision with acuity of 160/200, and tearing, which he had experienced soon after the injury. Firstly, we administered conventional drugs for eye injuries, including topical antibiotic, corticosteroid, and cycloplegic agents. After 2 days, corneal stromal infiltration and edema developed around the site of the sting, and visual acuity decreased to 100/200. These conditions led us to remove the stinger surgically. Within 25 days of follow-up, the corneal infiltration decreased gradually, and visual acuity improved to 180/200. We suggest a two-stage management approach for cases of corneal sting. For the first stage, if the stinger is readily accessible or primary dramatic reactions, including infiltration, especially on the visual axis, exist, manual or surgical removal would be indicated. Otherwise, we recommend conventional treatments for eye injuries. Given this situation, patients should be closely monitored for detection of any worsening. If the condition does not resolve or even deteriorates, for the second stage, surgical removal of the stinger under local or generalized anesthesia is indicated.Keywords: bee sting, stinger, cornea, removal, management, surgery

  5. Active Transforming Growth Factor-beta2 in the Aqueous Humor of Posterior Polymorphous Corneal Dystrophy Patients

    Czech Academy of Sciences Publication Activity Database

    Stádníková, A.; Ďuďáková, L.; Skalická, P.; Valenta, Zdeněk; Filipec, M.; Jirsová, K.

    2017-01-01

    Roč. 12, č. 4 (2017), č. článku e0175509. E-ISSN 1932-6203 Grant - others:GA ČR(CZ) GA17-12355S; GA MŠk(CZ) 7F14156 Institutional support: RVO:67985807 Keywords : transforming growth factor-beta2 * posterior polymorphous corneal dystrophy * corneal endothelial cells * general linear mixed-effect modelling * restricted maximum likelihood estimation Subject RIV: BB - Applied Statistics, Operational Research OBOR OECD: Statistics and probability Impact factor: 2.806, year: 2016

  6. Turning the tide of corneal blindness

    Directory of Open Access Journals (Sweden)

    Matthew S Oliva

    2012-01-01

    Full Text Available Corneal diseases represent the second leading cause of blindness in most developing world countries. Worldwide, major investments in public health infrastructure and primary eye care services have built a strong foundation for preventing future corneal blindness. However, there are an estimated 4.9 million bilaterally corneal blind persons worldwide who could potentially have their sight restored through corneal transplantation. Traditionally, barriers to increased corneal transplantation have been daunting, with limited tissue availability and lack of trained corneal surgeons making widespread keratoplasty services cost prohibitive and logistically unfeasible. The ascendancy of cataract surgical rates and more robust eye care infrastructure of several Asian and African countries now provide a solid base from which to dramatically expand corneal transplantation rates. India emerges as a clear global priority as it has the world′s largest corneal blind population and strong infrastructural readiness to rapidly scale its keratoplasty numbers. Technological modernization of the eye bank infrastructure must follow suit. Two key factors are the development of professional eye bank managers and the establishment of Hospital Cornea Recovery Programs. Recent adaptation of these modern eye banking models in India have led to corresponding high growth rates in the procurement of transplantable tissues, improved utilization rates, operating efficiency realization, and increased financial sustainability. The widespread adaptation of lamellar keratoplasty techniques also holds promise to improve corneal transplant success rates. The global ophthalmic community is now poised to scale up widespread access to corneal transplantation to meet the needs of the millions who are currently blind.

  7. Visual outcome after corneal transplantation for corneal perforation and iris prolapse in 37 horses

    DEFF Research Database (Denmark)

    Henriksen, Michala de Linde; Plummer, C. E.; Mangan, B.

    2012-01-01

    We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation.......We wanted to investigate the visual outcome of horses presented with iris prolapse and treated with corneal transplantation....

  8. Corneal Biofilms: From Planktonic to Microcolony Formation in an Experimental Keratitis Infection with Pseudomonas Aeruginosa.

    Science.gov (United States)

    Saraswathi, Padmanabhan; Beuerman, Roger W

    2015-10-01

    Microbial biofilms commonly comprise part of the infectious scenario, complicating the therapeutic approach. The purpose of this study was to determine in a mouse model of corneal infection if mature biofilms formed and to visualize the stages of biofilm formation. A bacterial keratitis model was established using Pseudomonas aeruginosa ATCC 9027 (1 × 10(8) CFU/ml) to infect the cornea of C57BL/6 black mouse. Eyes were examined post-infection (PI) on days 1, 2, 3, 5, and 7, and imaged by slit lamp microscopy, and light, confocal, and electron microscopy to identify the stages of biofilm formation and the time of appearance. On PI day 1, Gram staining showed rod-shaped bacteria adherent on the corneal surface. On PI days 2 and 3, bacteria were seen within webs of extracellular polymeric substance (EPS) and glycocalyx secretion, imaged by confocal microscopy. Scanning electron microscopy demonstrated microcolonies of active infectious cells bound with thick fibrous material. Transmission electron microscopy substantiated the formation of classical biofilm architecture with P. aeruginosa densely packed within the extracellular polymeric substances on PI days 5 and 7. Direct visual evidence showed that biofilms routinely developed on the biotic surface of the mouse cornea. The mouse model can be used to develop new approaches to deal therapeutically with biofilms in corneal infections. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Anterior corneal profile with variable asphericity.

    Science.gov (United States)

    Rosales, Marco A; Juárez-Aubry, Montserrat; López-Olazagasti, Estela; Ibarra, Jorge; Tepichín, Eduardo

    2009-12-10

    We present a corneal profile in which the eccentricity, e(Q=-e(2)), has a nonlinear continuous variation from the center outwards. This nonlinear variation is intended to fit and reproduce our current experimental data in which the anterior corneal surface of the human eye exhibits different values of e at different diameters. According to our clinical data, the variation is similar to an exponential decay. We propose a linear combination of two exponential functions to describe the variation of e. We then calculate the corneal sagittal height by substituting e in the first-order aspherical surface equation to obtain the corneal profile. This corneal profile will be used as a reference to analyze the resultant profiles of the customized corneal ablation in refractive surgery.

  10. Topical thrombin-related corneal calcification.

    Science.gov (United States)

    Kiratli, Hayyam; Irkeç, Murat; Alaçal, Sibel; Söylemezoğlu, Figen

    2006-09-01

    To report a highly unusual case of corneal calcification after brief intraoperative use of topical thrombin. A 44-year-old man underwent sclerouvectomy for ciliochoroidal leiomyoma, during which 35 UNIH/mL lyophilized bovine thrombin mixed with 9 mL of diluent containing 1500 mmol/mL calcium chloride was used. From the first postoperative day, corneal and anterior lenticular capsule calcifications developed, and corneal involvement slightly enlarged thereafter. A year later, 2 corneal punch biopsies confirmed calcification mainly in the Bowman layer. Topical treatment with 1.5% ethylenediaminetetraacetic acid significantly restored corneal clarity. Six months later, a standard extracapsular cataract extraction with intraocular lens placement improved visual acuity to 20/60. This case suggests that topical thrombin drops with elevated calcium concentrations may cause acute corneal calcification in Bowman layer and on the anterior lens capsule.

  11. Evaluation of corneal symmetry after UV corneal crosslinking for keratoconus

    Directory of Open Access Journals (Sweden)

    Mofty H

    2017-11-01

    Full Text Available Hanan Mofty,1,2 Khaled Alzahrani,2 Fiona Carley,3 Sophie Harper,3 Arun Brahma,3 Leon Au,3 Debbie Morley,3 M Chantal Hillarby2 1Optometry Department, College of Applied Medical Science, King Saud University, Riyadh, Kingdom of Saudi Arabia; 2Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, 3Manchester Royal Eye Hospital, Manchester, UK Purpose: The purpose of this study was to assess UV corneal crosslinking (CXL treatment outcomes for keratoconus by evaluating the corneal regularity in patients through follow-up using the Oculus Pentacam.Patients and methods: A total of 18 eyes from CXL patients with keratoconus were studied before and after CXL treatment, and six eyes from six patients who were not treated with CXL served as controls. Treated patients had Pentacam images taken before CXL treatment and regularly 3 months post treatment up to the 12th month. Controls were imaged during their first appointment and after 12 months. Symmetry and asphericity were evaluated and correlated with both best-corrected visual acuity (BCVA and maximum K-readings.Results: In the CXL-treated group, there was a significant improvement in the index of symmetrical variation (ISV and keratoconus index (KI at 3 months and in the index of height asymmetry (IHA and minimum radius of curvature (Rmin at 9 months post treatment. On the contrary, the untreated group’s indices showed some significant worsening in ISV, KI, central keratoconus index (CKI, and Rmin. A novel finding in our study was a slight positive shift of anterior asphericity in the 6 mm, 7 mm, and 8 mm 3 months after treatment, which had a correlation with BCVA (R2=0.390, p=0.053 and a strong correlation with maximum K-reading (R2=0.690, p=0.005. However, the untreated group had no significant changes after 1 year.Conclusion: The corneal asymmetrical shape is associated with the spherical aberration alteration

  12. Diospyros kaki Extract Inhibits Alkali Burn-Induced Corneal Neovascularization.

    Science.gov (United States)

    Yang, Sung Jae; Jo, Hyoung; Kim, Kyung-A; Ahn, Hong Ryul; Kang, Suk Woo; Jung, Sang Hoon

    2016-01-01

    The purpose of this study was to evaluate the effect of ethanol extract of Diospyros kaki (EEDK) leaves on corneal neovascularization (CoNV) in rats. One week after the alkali burns in the corneas, the CoNV area coverage in the CoNV-positive control group, 100 mg/kg EEDK group, and 200 mg/kg EEDK group was 43.3% ± 5.5%, 337.7% ± 2.5%, and 27.2% ± 4.3%, respectively. The areas of CoNV in the EEDK-treated groups were significantly different from those of the CoNV group. EEDK significantly attenuated the upregulation of vascular endothelial growth factor, fibroblast growth factor, interleukin-6, and matrix metalloproteinase-2 (MMP-2) protein levels. Orally administrated D. kaki inhibited CoNV development in rats.

  13. Corneal Transplantation in Auckland, New Zealand, 1999-2009: Indications, Patient Characteristics, Ethnicity, Social Deprivation, and Access to Services.

    Science.gov (United States)

    Crawford, Alexandra Z; McKelvie, James; Craig, Jennifer P; McGhee, Charles N J; Patel, Dipika V

    2017-05-01

    To analyze characteristics and indications for corneal transplantation in patients undergoing penetrating, lamellar, and endothelial keratoplasty in Auckland, New Zealand (NZ). Corneal transplantation data from the NZ National Eye Bank and hospital records of corneal transplant recipients in the Auckland region from January 1, 2000, to December 31, 2009, were collated. Patient demographics, preoperative diagnosis, indication, ocular and medical history, visual acuity, deprivation index, and access to transplantation surgery were analyzed. A total of 941 corneal transplants involving 770 patients were included for analysis. Mean age was 46 years. Age and ethnicity varied according to the transplant indication. A male preponderance and disproportionally high rates of Māori and Pacific ethnicity with a mean age of 30 years were observed in transplants for keratoconus. A total of 67.2% of corneal transplants were completed in the public health system and were associated with higher levels of deprivation than those completed in private facilities. Preoperative visual acuity varied according to the transplant type and indication. The most common clinical indication for corneal transplantation was keratoconus (41.3%), followed by repeat transplantation (21.0%). There was no significant change in the relative proportion of transplant indications in any year over the duration of this study (P = 0.41). A contralateral corneal transplant was present in 24.4% and glaucoma in 12.8% of penetrating keratoplasty recipients. Keratoconus is the leading indication for corneal transplantation in Auckland, NZ, and involves a disproportionately high rate of Māori and Pacific transplant recipients with a male preponderance and comparatively low mean age at the time of surgery.

  14. Corneal iron ring after conductive keratoplasty.

    Science.gov (United States)

    Kymionis, George D; Naoumidi, Tatiana L; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-08-01

    To report formation of corneal iron ring deposits after conductive keratoplasty. Observational case report. Case report. A 54-year-old woman underwent conductive keratoplasty for hyperopia. One year after conductive keratoplasty, iron ring pattern pigmentation was detected at the corneal epithelium of both eyes. This is the first report of the appearance of corneal iron ring deposits following conductive keratoplasty treatment in a patient. It is suggested that alterations in tear film stability, resulting from conductive keratoplasty-induced changes in corneal curvature, constitute the contributory factor for these deposits.

  15. Mouse adenovirus type 1 infection of macrophages

    NARCIS (Netherlands)

    Ashley, S.L.; Welton, A.R.; Harwood, K.M.; Rooijen, van N.; Spindler, K.R.

    2009-01-01

    Mouse adenovirus type 1 (MAV-1) causes acute and persistent infections in mice, with high levels of virus found in the brain, spinal cord and spleen in acute infections. MAV-1 infects endothelial cells throughout the mouse, and monocytes/macrophages have also been implicated as targets of the virus.

  16. The relationship between corneal biomechanical properties and confocal microscopy findings in normal and keratoconic eyes.

    Science.gov (United States)

    Hurmeric, Volkan; Sahin, Afsun; Ozge, Gokhan; Bayer, Atilla

    2010-06-01

    To investigate the relationship between corneal biomechanical properties and confocal microscopy (CM) findings in normal and keratoconic eyes. The study consisted of 28 eyes of 28 healthy volunteers and 23 eyes of 15 patients with keratoconus. The diagnosis of keratoconus was made with corneal topography and clinical findings. The corneal hysteresis (CH) and corneal resistance factor (CRF) were measured by the ocular response analyzer. In vivo CM was performed with NIDEK Confoscan 3. CH and CRF were compared with corneal morphological findings (detailed cell counts of endothelial, stromal, and epithelial cells) in vivo. CH was 10.1 +/- 1.3 mm Hg in normal eyes and 7.4 +/- 1.5 mm Hg in keratoconic eyes (P < 0.0001). CRF was 10.1 +/- 1.8 mm Hg in normal eyes and 6.2 +/- 1.4 mm Hg in keratoconic eyes (P < 0.0001). CH and CRF were negatively correlated with full-thickness stromal keratocyte density (P < 0.01; r = -0.52 and P < 0.001; r = -0.67, respectively) in healthy eyes. Keratocyte density of the posterior half of the stroma was found to be significantly related with CRF in healthy eyes (beta = -0.404; P = 0.01). There was no significant relationship among CH, CRF, and CM findings in eyes with keratoconus. There is a significant relationship between CRF and keratocyte density of the posterior half of the stroma in healthy eyes. Our results suggest that corneal elasticity is related to not only stromal matrix but also cellular structure of the cornea.

  17. The Role of Titanium Surface Microtopography on Adhesion, Proliferation, Transformation, and Matrix Deposition of Corneal Cells.

    Science.gov (United States)

    Zhou, Chengxin; Lei, Fengyang; Chodosh, James; Paschalis, Eleftherios I

    2016-04-01

    Titanium (Ti) is an excellent implantable biomaterial that can be further enhanced by surface topography optimization. Despite numerous data from orthopedics and dentistry, the effect of Ti surface topography on ocular cells is still poorly understood. In light of the recent adaptation of Ti in the Boston Keratoprosthesis artificial cornea, we attempted to perform an extended evaluation of the effect of Ti surface topography on corneal cell adhesion, proliferation, cytotoxicity, transformation, and matrix deposition. Different surface topographies were generated on medical grade Ti-6Al-4V-ELI (extra-low interstitial), with linearly increased roughness (polished to grit blasted). Biological response was evaluated in vitro using human corneal limbal epithelial (HCLE) cells, stromal fibroblasts (HCF), and endothelial cells (HCEnC). None of the Ti surface topographies caused cytotoxicity to any of the three corneal cell types. However, rough Ti surface inhibited HCLE and HCF cell adhesion and proliferation, while HCEnC proliferation was unaffected. Long-term experiments with HCF revealed that rough Ti surface with R(a) (the arithmetic average of the profile height from the mean line) ≥ 1.15 μm suppressed HCF focal adhesion kinase phosphorylation, changed fibroblast morphology, and caused less aligned and reduced deposition of collagen matrix as compared to smooth Ti (R(a) ≤ 0.08 μm). In the presence of transforming growth factor β1 (TGFβ1) stimulation, rough Ti inhibited alpha-smooth muscle actin (α-SMA) expression and collagen deposition, leading to decreased myofibroblast transformation and disorganization of the collagen fibrils as compared to smooth Ti. This study suggests that Ti surface topography regulates corneal cell behavior in a tissue-dependent manner that varies across the corneal strata. Contrary to the accepted paradigm, smooth surface topography can enhance cell adhesion and proliferation and increase matrix deposition by corneal cells.

  18. Corneal Structural Changes in Nonneoplastic and Neoplastic Monoclonal Gammopathies.

    Science.gov (United States)

    Aragona, Pasquale; Allegra, Alessandro; Postorino, Elisa Imelde; Rania, Laura; Innao, Vanessa; Wylegala, Edward; Nowinska, Anna; Ieni, Antonio; Pisani, Antonina; Musolino, Caterina; Puzzolo, Domenico; Micali, Antonio

    2016-05-01

    To investigate corneal confocal microscopic changes in nonneoplastic and neoplastic monoclonal gammopathies. Three groups of subjects were considered: group 1, twenty normal subjects; group 2, fifteen patients with monoclonal gammopathy of undetermined significance (MGUS); group 3, eight patients with smoldering multiple myeloma and eight patients with untreated multiple myeloma. After hematologic diagnosis, patients underwent ophthalmologic exam and in vivo confocal microscopic study. The statistical analysis was performed using ANOVA and Student-Newman-Keuls tests and receiver operating characteristic (ROC) curve analysis. Epithelial cells of gammopathic patients showed significantly higher reflectivity than controls, demonstrated by optical density (P < 0.001). Subbasal nerve density, branching, and beading were significantly altered in gammopathic patients (P = 0.01, P = 0.02, P = 0.02, respectively). The number of keratocytes was significantly reduced in neoplastic patients (P < 0.001 versus both normal and MGUS) in the anterior, medium, and posterior stroma. The ROC curve analysis showed good sensitivity and specificity for this parameter. Group 2 and 3 keratocytes showed higher nuclear and cytoplasmatic reflectivity in the medium and posterior stroma. Endothelial cells were not affected. Patients with neoplastic gammopathies showed peculiar alterations of the keratocyte number, which appeared significantly reduced. A follow-up with corneal confocal microscopy of patients with MGUS is suggested as a useful tool to identify peripheral tissue alterations linked to possible neoplastic disease development.

  19. A robotic platform for laser welding of corneal tissue

    Science.gov (United States)

    Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo

    2017-07-01

    Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.

  20. Therapeutic Effects of Topical Netrin-4 Inhibits Corneal Neovascularization in Alkali-Burn Rats

    Science.gov (United States)

    Han, Yun; Shao, Yi; Liu, Tingting; Qu, Yang-Luowa; Li, Wei; Liu, Zuguo

    2015-01-01

    Netrins are secreted molecules involved in axon guidance and angiogenesis. However, the role of netrins in the vasculature remains unclear. Netrin-4 and netrin-1 have been found to be either pro- or antiangiogenic factors. Previously, we found that netrin-1 acts as an anti-angiogenic factor in rats by inhibiting alkali burn-induced corneal neovascularization. Here, we further investigate the effects of netrin-4, another member of the same netrin family, on neovascularization in vitro and in vivo. We found that netrin-4 functions similarly as netrin-1 in angiogenesis. In vitro angiogenesis assay shows that netrin-4 affected human umbilical vein endothelial cell (HUVEC) tube formation, viability and proliferation, apoptosis, migration, and invasion in a dose-dependent manner. Netrin-4 was topically applied in vivo to alkali-burned rat corneas on day 0 (immediately after injury) and/or day 10 post-injury. Netrin-4 subsequently suppressed and reversed corneal neovascularization. Netrin-4 inhibited corneal epithelial and stromal cell apoptosis, inhibited vascular endothelial growth factor (VEGF), but promoted pigment epithelium-derived factor (PEDF) expression, decreased NK-KB p65 expression, and inhibits neutrophil and macrophage infiltration. These results indicate that netrin-4 shed new light on its potential roles in treatmenting for angiogenic diseases that affect the ocular surface, as well as other tissues. PMID:25853509

  1. Effect of chemical composition on corneal cellular response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid

    International Nuclear Information System (INIS)

    Lai, Jui-Yang

    2013-01-01

    Characterization of corneal cellular response to hydrogel materials is an important issue in ophthalmic applications. In this study, we aimed to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and material compatibility towards corneal stromal and endothelial cells. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Results of electrokinetic measurements showed that an increase in absolute zeta potential of photopolymerized membranes is observed with increasing the volume ratios of AAc/HEMA. Following 4 days of incubation with various hydrogels, the primary rabbit corneal stromal and endothelial cell cultures were examined for viability, proliferation, and pro-inflammatory gene expression. The samples prepared from the solution mixture containing 0–10 vol.% AAc displayed good cytocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the decreased viability, inhibited proliferation, and stimulated inflammation were noted in both cell types, probably due to the stronger charge–charge interactions. On the other hand, the ionic pump function of corneal endothelial cells exposed to photopolymerized membranes was examined by analyzing the Na + ,K + -ATPase alpha 1 subunit (ATP1A1) expression level. The presence of material samples having higher anionic charge density (i.e., zeta potential of − 38 to − 56 mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal stromal and endothelial cell responses to polymeric biomaterials. - Highlights: • We examine the corneal cellular responses to photopolymerized biomaterials. • Charge density of membranes was increased with increasing volume ratio of AAc/HEMA. • 15–20 vol.% AAc decreased viability and proliferation of all

  2. Effect of chemical composition on corneal cellular response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Jui-Yang, E-mail: jylai@mail.cgu.edu.tw

    2013-10-15

    Characterization of corneal cellular response to hydrogel materials is an important issue in ophthalmic applications. In this study, we aimed to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and material compatibility towards corneal stromal and endothelial cells. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Results of electrokinetic measurements showed that an increase in absolute zeta potential of photopolymerized membranes is observed with increasing the volume ratios of AAc/HEMA. Following 4 days of incubation with various hydrogels, the primary rabbit corneal stromal and endothelial cell cultures were examined for viability, proliferation, and pro-inflammatory gene expression. The samples prepared from the solution mixture containing 0–10 vol.% AAc displayed good cytocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the decreased viability, inhibited proliferation, and stimulated inflammation were noted in both cell types, probably due to the stronger charge–charge interactions. On the other hand, the ionic pump function of corneal endothelial cells exposed to photopolymerized membranes was examined by analyzing the Na{sup +},K{sup +}-ATPase alpha 1 subunit (ATP1A1) expression level. The presence of material samples having higher anionic charge density (i.e., zeta potential of − 38 to − 56 mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal stromal and endothelial cell responses to polymeric biomaterials. - Highlights: • We examine the corneal cellular responses to photopolymerized biomaterials. • Charge density of membranes was increased with increasing volume ratio of AAc/HEMA. • 15–20 vol.% AAc decreased viability and proliferation

  3. Sustainability of Routine Notification and Request legislation on eye bank tissue supply and corneal transplantation wait times in Canada.

    Science.gov (United States)

    Lee, Kenneth; Boimer, Corey; Hershenfeld, Samantha; Sharpen, Linda; Slomovic, Allan R

    2011-10-01

    To assess whether provinces with Routine Notification and Request (RNR) legislation have sustained increases in corneal tissue supply and decreases in wait times for corneal transplantation surgery. Cross-sectional survey of Canadian corneal transplant (CT) surgeons and eye banks. Canadian CT surgeons and representatives from the 10 Canadian eye banks. Voluntary and anonymous surveys were distributed between July and October 2009. Eligible CT surgeons were defined as ophthalmologists who practice in Canada; currently perform Penetrating keratoplasty (PKP), Deep anterior lamellar keratoplasty (DALK), Deep lamellar endothelial keratoplasty (DLEK), Descemet stripping endothelial keratoplasty (DSEK), or Descemet membrane endothelial keratoplasty (DMEK); and have obtained tissues from a Canadian eye bank. From 2006 to 2009, for provinces with RNR legislation and where data are available, mean wait times from date of diagnosis to date of CT surgery have increased: in Ontario, from 31 ± 34 weeks to 36 ± 27 weeks; in British Columbia, from 39 ± 20 weeks to 42 ± 35 weeks; in Manitoba, from 32 ± 23 weeks to 49 ± 36 weeks. In addition, the amount of corneal tissue in RNR provinces suitable for transplant, with the exception of British Columbia, has declined between 2006 and 2008: in Ontario, 1186 tissues to 999 tissues (16% decline); in Manitoba, 92 tissues to 83 tissues (10% decline); in New Brunswick, 129 tissues to 98 tissues (24% decline). Although initially effective, RNR legislation has not sustained an increase in corneal tissue availability nor has it shortened wait times in most provinces. Incorporation of community hospitals into the RNR catchment, improved enforcement, and continued education of hospital staff regarding the RNR process may be effective in making this legislation more sustainable in the long term. Copyright © 2011 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Management of corneal ectasia after LASIK with combined, same-day, topography-guided partial transepithelial PRK and collagen cross-linking: the athens protocol.

    Science.gov (United States)

    Kanellopoulos, Anastasios John; Binder, Perry S

    2011-05-01

    To evaluate a series of patients with corneal ectasia after LASIK that underwent the Athens Protocol: combined topography-guided photorefractive keratectomy (PRK) to reduce or eliminate induced myopia and astigmatism followed by sequential, same-day ultraviolet A (UVA) corneal collagen cross-linking (CXL). Thirty-two consecutive corneal ectasia cases underwent transepithelial PRK (WaveLight ALLEGRETTO) immediately followed by CXL (3 mW/cm(2)) for 30 minutes using 0.1% topical riboflavin sodium phosphate. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, keratometry, central ultrasonic pachymetry, corneal tomography (Oculus Pentacam), and endothelial cell counts were analyzed. Mean follow-up was 27 months (range: 6 to 59 months). Twenty-seven of 32 eyes had an improvement in UDVA and CDVA of 20/45 or better (2.25 logMAR) at last follow-up. Four eyes showed some topographic improvement but no improvement in CDVA. One of the treated eyes required a subsequent penetrating keratoplasty. Corneal haze grade 2 was present in 2 eyes. Combined, same-day, topography-guided PRK and CXL appeared to offer tomographic stability, even after long-term follow-up. Only 2 of 32 eyes had corneal ectasia progression after the intervention. Seventeen of 32 eyes appeared to have improvement in UDVA and CDVA with follow-up >1.5 years. This technique may offer an alternative in the management of iatrogenic corneal ectasia. Copyright 2011, SLACK Incorporated.

  5. Changes in the corneal Na-K ATPase levels in eyes stored in moist chamber at 4°C

    Directory of Open Access Journals (Sweden)

    Devi B

    1996-01-01

    Full Text Available This report deals with a chronological measurement of Na-K ATPase enzyme activity in human and bovine corneas stored in a moist chamber at 4°C. Paired human and bovine eyes were sterilized by the standard eye bank procedure and stored up to 6 days. At the desired time, the corneal endothelium was assayed for Na-K ATPase activity. The protein content of each tissue sample was also determined. In a parallel set of experiments, the viability of identical stored corneas was determined by trypan blue and alizarin red staining technique, and morphometric analysis was done to quantify the extent of the corneal endothelial damage. The human corneas showed that there was a significant progressive decrease in the Na-K ATPase activity as the storage time increased. The decrease was related to morphological endothelial damage.

  6. Rechazo y retrasplante corneal Corneal rejection and re-transplantation

    Directory of Open Access Journals (Sweden)

    Miguel O Mokey Castellanos

    2007-06-01

    Full Text Available Se efectuó una investigación observacional análítica retrospectiva, sobre los transplantes corneales efectuados en el Servicio de Oftalmología del Hospital "Hermanos Ameijeiras. Rechazaron 76 pacientes, que se compararon con un control de 89 pacientes, que en un período similar no tuvieron rechazo. El queratocono fue la afección corneal que predominó. El primer lugar en los rechazos correspondió a queratoherpes (43,5 %. El menor índice de rechazo fue para el queratocono (8,8 %. Se analizó la multiplicidad de rechazos; y fue frecuente que se presentara un solo rechazo, aunque sí hubo congruencia entre el número de rechazos y la necesidad de retrasplantes. Se encontró que los resultados de la conducta médica o quirúrgica se relacionaban con la causa. Se calcula un índice de supervivencia (Kaplan-Meier, que concluye que en los primeros dos años existe menos posibilidad de aparición de rechazoAn retrospective observational analytical research was conducted on corneal transplants performed at Ophthalmological Service in “Hermanos Ameijeiras” hospital . Seventy six patients had graft rejection and were compared to a control group of 89 patients that did not present rejection in the same period of time. Keratoconus was the prevailing corneal problem. The highest rejection rate corresponded to keratoherpes (43,5% whereas the lowest rate was for keratoconus (8,8%. Multiplicity of rejections was analyzed and it was found that mostly one graft rejection occured, but number of rejections was associated with the need of re-transplantation. It was found that the results of medical or surgical performance were related to the cause of graft rejection. A survival index (Kaplan-Meier was estimated, which showed that occurence of graf rejection is less probable in the first two years

  7. An easy and inexpensive method for quantitative analysis of endothelial damage by using vital dye staining and Adobe Photoshop software.

    Science.gov (United States)

    Saad, Hisham A; Terry, Mark A; Shamie, Neda; Chen, Edwin S; Friend, Daniel F; Holiman, Jeffrey D; Stoeger, Christopher

    2008-08-01

    We developed a simple, practical, and inexpensive technique to analyze areas of endothelial cell loss and/or damage over the entire corneal area after vital dye staining by using a readily available, off-the-shelf, consumer software program, Adobe Photoshop. The purpose of this article is to convey a method of quantifying areas of cell loss and/or damage. Descemet-stripping automated endothelial keratoplasty corneal transplant surgery was performed by using 5 precut corneas on a human cadaver eye. Corneas were removed and stained with trypan blue and alizarin red S and subsequently photographed. Quantitative assessment of endothelial damage was performed by using Adobe Photoshop 7.0 software. The average difference for cell area damage for analyses performed by 1 observer twice was 1.41%. For analyses performed by 2 observers, the average difference was 1.71%. Three masked observers were 100% successful in matching the randomized stained corneas to their randomized processed Adobe images. Vital dye staining of corneal endothelial cells can be combined with Adobe Photoshop software to yield a quantitative assessment of areas of acute endothelial cell loss and/or damage. This described technique holds promise for a more consistent and accurate method to evaluate the surgical trauma to the endothelial cell layer in laboratory models. This method of quantitative analysis can probably be generalized to any area of research that involves areas that are differentiated by color or contrast.

  8. Técnica de separação da membrana de Descemet para transplante de células endoteliais da córnea: estudo experimental em coelhos Technique for separating Descemet membrane for corneal endothelial cells transplantation: experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Daniel Wasilewski

    2010-02-01

    Full Text Available OBJETIVO: Avaliar a porcentagem de dano endotelial induzido por uma técnica cirúrgica para a separação da membrana de Descemet contendo endotélio sadio, analisar a viabilidade e eficácia desta técnica, e avaliar a porcentagem de dano endotelial causado pela inversão da córnea em câmara anterior artificial. MÉTODOS: As córneas de três grupos de 12 coelhos da linhagem Nova Zelândia foram avaliadas. O grupo 1 foi usado como controle; portanto, as córneas foram analisadas após coletadas e trepanadas. O grupo 2 foi analisado após a inversão da córnea (endotélio para cima na posição convexa, montada em câmara anterior artificial, para o cálculo da porcentagem do dano endotelial induzido por esta inversão. O grupo 3 foi avaliado após a separação entre a membrana de Descemet e o estroma com o uso de substância viscoelástica em córneas invertidas e montadas em câmara anterior artificial. O dano endotelial foi avaliado por meio de fotografias digitais tiradas no microscópio após impregnar o endotélio com vermelho de alizarina. Amostras do grupo 3 foram processadas para avaliação histopatológica. RESULTADOS: O grupo 3 (separação viscoelástica apresentou um índice de lesão celular endotelial de 10,06%, o grupo 2 apresentou um índice de 3,58% e o grupo controle um índice de 0,18% de lesão celular endotelial (pPURPOSE: To evaluate the percentage of endothelial cell damage induced during a surgical technique of Descemet's membrane separation containing healthy endothelium, analyze the viability and efficacy of this technique, and evaluate the percentage of endothelial cell damage caused by inversion of the cornea on an artificial anterior chamber. METHODS: The corneas from three groups of 12 New Zealand rabbits were evaluated. The Group one was used as the control, so the corneas were analyzed after collected and trephinated. The Group two was analyzed after inversion of the cornea (endothelial side up at a convex

  9. Corynebacterium macginleyi isolated from a corneal ulcer

    Directory of Open Access Journals (Sweden)

    Kathryn Ruoff

    2010-02-01

    Full Text Available We report the isolation of Corynebacterium macginleyi from the corneal ulcer culture of a patient, later enrolled in the Steroids for Corneal Ulcer Trial (SCUT. To our knowledge this is the first published report from North America of the recovery of C. macginleyi from a serious ocular infection.

  10. Do topical antibiotics help corneal epithelial trauma?

    OpenAIRE

    King, J. W.; Brison, R. J.

    1993-01-01

    Topical antibiotics are routinely used in emergency rooms to treat corneal trauma, although no published evidence supports this treatment. In a noncomparative clinical trial, 351 patients with corneal epithelial injuries were treated without antibiotics. The infection rate was 0.7%, suggesting that such injuries can be safely and effectively managed without antibiotics. A comparative clinical trial is neither warranted nor feasible.

  11. Corneal laceration caused by river crab

    Directory of Open Access Journals (Sweden)

    Vinuthinee N

    2015-01-01

    Full Text Available Naidu Vinuthinee,1,2 Anuar Azreen-Redzal,1 Jaafar Juanarita,1 Embong Zunaina2 1Department of Ophthalmology, Hospital Sultanah Bahiyah, Alor Setar, 2Department of Ophthalmology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Malaysia Abstract: A 5-year-old boy presented with right eye pain associated with tearing and photophobia of 1-day duration. He gave a history of playing with a river crab when suddenly the crab clamped his fingers. He attempted to fling the crab off, but the crab flew and hit his right eye. Ocular examination revealed a right eye corneal ulcer with clumps of fibrin located beneath the corneal ulcer and 1.6 mm level of hypopyon. At presentation, the Seidel test was negative, with a deep anterior chamber. Culture from the corneal scrapping specimen grew Citrobacter diversus and Proteus vulgaris, and the boy was treated with topical gentamicin and ceftazidime eyedrops. Fibrin clumps beneath the corneal ulcer subsequently dislodged, and revealed a full-thickness corneal laceration wound with a positive Seidel test and shallow anterior chamber. The patient underwent emergency corneal toileting and suturing. Postoperatively, he was treated with oral ciprofloxacin 250 mg 12-hourly for 1 week, topical gentamicin, ceftazidime, and dexamethasone eyedrops for 4 weeks. Right eye vision improved to 6/9 and 6/6 with pinhole at the 2-week follow-up following corneal suture removal. Keywords: corneal ulcer, pediatric trauma, ocular injury

  12. Designing Hydrogel Adhesives for Corneal Wound Repair

    Science.gov (United States)

    Grinstaff, Mark W.

    2013-01-01

    Today, corneal wounds are repaired using nylon sutures. Yet there are a number of complications associated with suturing the cornea, and thus there is interest in an adhesive to replace or supplement sutures in the repair of corneal wounds. We are designing and evaluating corneal adhesives prepared from dendrimers – single molecular weight, highly branched polymers. We have explored two strategies to form these ocular adhesives. The first involves a photocrosslinking reaction and the second uses a peptide ligation reactions to couple the individual dendrimers together to from the adhesive. These adhesives were successfully used to repair corneal perforations, close the flap produced in a LASIK procedure, and secure a corneal transplant. PMID:17889330

  13. Healed corneal ulcer with keloid formation.

    Science.gov (United States)

    Alkatan, Hind M; Al-Arfaj, Khalid M; Hantera, Mohammed; Al-Kharashi, Soliman

    2012-04-01

    We are reporting a 34-year-old Arabic white female patient who presented with a white mass covering her left cornea following multiple ocular surgeries and healed corneal ulcer. The lesion obscured further view of the iris, pupil and lens. The patient underwent penetrating keratoplasty and the histopathologic study of the left corneal button showed epithelial hyperplasia, absent Bowman's layer and subepithelial fibrovascular proliferation. The histopathologic appearance was suggestive of a corneal keloid which was supported by further ultrastructural study. The corneal graft remained clear 6 months after surgery and the patient was satisfied with the visual outcome. Penetrating keratoplasty may be an effective surgical option for corneal keloids in young adult patients.

  14. The SULFs, extracellular sulfatases for heparan sulfate, promote the migration of corneal epithelial cells during wound repair.

    Directory of Open Access Journals (Sweden)

    Inna Maltseva

    Full Text Available Corneal epithelial wound repair involves the migration of epithelial cells to cover the defect followed by the proliferation of the cells to restore thickness. Heparan sulfate proteoglycans (HSPGs are ubiquitous extracellular molecules that bind to a plethora of growth factors, cytokines, and morphogens and thereby regulate their signaling functions. Ligand binding by HS chains depends on the pattern of four sulfation modifications, one of which is 6-O-sulfation of glucosamine (6OS. SULF1 and SULF2 are highly homologous, extracellular endosulfatases, which post-synthetically edit the sulfation status of HS by removing 6OS from intact chains. The SULFs thereby modulate multiple signaling pathways including the augmentation of Wnt/ß-catenin signaling. We found that wounding of mouse corneal epithelium stimulated SULF1 expression in superficial epithelial cells proximal to the wound edge. Sulf1⁻/⁻, but not Sulf2⁻/⁻, mice, exhibited a marked delay in healing. Furthermore, corneal epithelial cells derived from Sulf1⁻/⁻ mice exhibited a reduced rate of migration in repair of a scratched monolayer compared to wild-type cells. In contrast, human primary corneal epithelial cells expressed SULF2, as did a human corneal epithelial cell line (THCE. Knockdown of SULF2 in THCE cells also slowed migration, which was restored by overexpression of either mouse SULF2 or human SULF1. The interchangeability of the two SULFs establishes their capacity for functional redundancy. Knockdown of SULF2 decreased Wnt/ß-catenin signaling in THCE cells. Extracellular antagonists of Wnt signaling reduced migration of THCE cells. However in SULF2- knockdown cells, these antagonists exerted no further effects on migration, consistent with the SULF functioning as an upstream regulator of Wnt signaling. Further understanding of the mechanistic action of the SULFs in promoting corneal repair may lead to new therapeutic approaches for the treatment of corneal injuries.

  15. Donor disc attachment assessment with intraoperative spectral optical coherence tomography during descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Edward Wylegala

    2013-01-01

    Full Text Available Optical coherence tomography has already been proven to be useful for pre- and post-surgical anterior eye segment assessment, especially in lamellar keratoplasty procedures. There is no evidence for intraoperative usefulness of optical coherence tomography (OCT. We present a case report of the intraoperative donor disc attachment assessment with spectral-domain optical coherence tomography in case of Descemet stripping automated endothelial keratoplasty (DSAEK surgery combined with corneal incisions. The effectiveness of the performed corneal stab incisions was visualized directly by OCT scan analysis. OCT assisted DSAEK allows the assessment of the accuracy of the Descemet stripping and donor disc attachment.

  16. VISUAL PERCEPTION BASED AUTOMATIC RECOGNITION OF CELL MOSAICS IN HUMAN CORNEAL ENDOTHELIUMMICROSCOPY IMAGES

    Directory of Open Access Journals (Sweden)

    Yann Gavet

    2011-05-01

    Full Text Available The human corneal endothelium can be observed with two types of microscopes: classical optical microscope for ex-vivo imaging, and specular optical microscope for in-vivo imaging. The quality of the cornea is correlated to the endothelial cell density and morphometry. Automatic methods to analyze the human corneal endothelium images are still not totally efficient. Image analysis methods that focus only on cell contours do not give good results in presence of noise and of bad conditions of acquisition. More elaborated methods introduce regional informations in order to performthe cell contours completion, thus implementing the duality contour-region. Their good performance can be explained by their connections with several basic principles of human visual perception (Gestalt Theory and Marr's computational theory.

  17. Late onset corneal ectasia after LASIK surgery.

    Science.gov (United States)

    Said, Ashraf; Hamade, Issam H; Tabbara, Khalid F

    2011-07-01

    To report late onset corneal ectasia following myopic LASIK. A retrospective cohort case series. Nineteen patients with late onset corneal ectasia following LASIK procedure were examined at The Eye Center, Riyadh, Saudi Arabia. Patients underwent LASIK for myopia with spherical equivalent ranging from -1.4 to -13.75 diopters. Age and gender, history of systemic or local diseases, and time of onset of corneal ectasia were recorded. Eye examination and corneal topographical analyses were done before and after LASIK surgery. Nineteen patients (29 eyes) with late onset corneal ectasia were identified from 1998 to 2008 in 13 male and six female patients. The mean follow-up period was 108 ± 23 months (range 72-144 months). No patient had pre-operative identifiable risk factors for corneal ectasia and the mean time of onset was 57 ± 24 months (range 24-120 months after LASIK). The pre-operative values included mean central pachymetry 553 ± 25 μm, mean keratometry reading of 42.9 ± 1.5 diopters, average oblique cylinder of 1.4 ± 1.2 diopters, posterior surface elevation of 26 ± 2.1 diopters, corneal flap thickness of 160 μm, mean spherical equivalent of -5.6 ± 3.6 diopters, and calculated residual corneal stromal bed thickness was 288 ± 35 μm. Three (5 eyes) patients developed ectasia after pregnancy. Three (4 eyes) patients developed corneal ectasia following severe adenoviral keratoconjunctivitis and had positive PCR for adenovirus type 8. Corneal ectasia may develop many years after LASIK surgery and symptoms could go undetected for some time. Pregnancy and adenoviral keratoconjunctivitis occurred post-operatively in six patients.

  18. Segmentation of corneal endothelium images using a U-Net-based convolutional neural network.

    Science.gov (United States)

    Fabijańska, Anna

    2018-04-18

    Diagnostic information regarding the health status of the corneal endothelium may be obtained by analyzing the size and the shape of the endothelial cells in specular microscopy images. Prior to the analysis, the endothelial cells need to be extracted from the image. Up to today, this has been performed manually or semi-automatically. Several approaches to automatic segmentation of endothelial cells exist; however, none of them is perfect. Therefore this paper proposes to perform cell segmentation using a U-Net-based convolutional neural network. Particularly, the network is trained to discriminate pixels located at the borders between cells. The edge probability map outputted by the network is next binarized and skeletonized in order to obtain one-pixel wide edges. The proposed solution was tested on a dataset consisting of 30 corneal endothelial images presenting cells of different sizes, achieving an AUROC level of 0.92. The resulting DICE is on average equal to 0.86, which is a good result, regarding the thickness of the compared edges. The corresponding mean absolute percentage error of cell number is at the level of 4.5% which confirms the high accuracy of the proposed approach. The resulting cell edges are well aligned to the ground truths and require a limited number of manual corrections. This also results in accurate values of the cell morphometric parameters. The corresponding errors range from 5.2% for endothelial cell density, through 6.2% for cell hexagonality to 11.93% for the coefficient of variation of the cell size. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Construction of a human corneal stromal equivalent with non-transfected human corneal stromal cells and acellular porcine corneal stromata.

    Science.gov (United States)

    Diao, Jin-Mei; Pang, Xin; Qiu, Yue; Miao, Ying; Yu, Miao-Miao; Fan, Ting-Jun

    2015-03-01

    A tissue-engineered human corneal stroma (TE-HCS) has been developed as a promising equivalent to the native corneal stroma for replacement therapy. However, there is still a crucial need to improve the current approaches to render the TE-HCS equivalent more favorable for clinical applications. At the present study, we constructed a TE-HCS by incubating non-transfected human corneal stromal (HCS) cells in an acellular porcine corneal stromata (aPCS) scaffold in 20% fetal bovine serum supplemented DMEM/F12 (1:1) medium at 37 °C with 5% CO2in vitro. After 3 days of incubation, the constructed TE-HCS had a suitable tensile strength for transplantation, and a transparency that is comparable to native cornea. The TE-HCS had a normal histological structure which contained regularly aligned collagen fibers and differentiated HCS cells with positive expression of marker and functional proteins, mimicking a native HCS. After transplantation into rabbit models, the TE-HCS reconstructed normal corneal stroma in vivo and function well in maintaining corneal clarity and thickness, indicating that the completely biological TE-HCS could be used as a HCS equivalent. The constructed TE-HCS has promising potentials in regenerative medicine and treatment of diseases caused by corneal stromal disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Intraoperative corneal thickness measurements during corneal collagen cross-linking with isotonic riboflavin solution without dextran in corneal ectasia.

    Science.gov (United States)

    Cınar, Yasin; Cingü, Abdullah Kürşat; Sahin, Alparslan; Türkcü, Fatih Mehmet; Yüksel, Harun; Caca, Ihsan

    2014-03-01

    Abstract Objective: To monitor the changes in corneal thickness during the corneal collagen cross-linking procedure by using isotonic riboflavin solution without dextran in ectatic corneal diseases. The corneal thickness measurements were obtained before epithelial removal, after epithelial removal, following the instillation of isotonic riboflavin solution without dextran for 30 min, and after 10 min of ultraviolet A irradiation. Eleven eyes of eleven patients with progressive keratoconus (n = 10) and iatrogenic corneal ectasia (n = 1) were included in this study. The mean thinnest pachymetric measurements were 391.82 ± 30.34 µm (320-434 µm) after de-epithelialization of the cornea, 435 ± 21.17 µm (402-472 µm) following 30 min instillation of isotonic riboflavin solution without dextran and 431.73 ± 20.64 µm (387-461 µm) following 10 min of ultraviolet A irradiation to the cornea. Performing corneal cross-linking procedure with isotonic riboflavin solution without dextran might not induce corneal thinning but a little swelling throughout the procedure.

  1. Corneal modeling for analysis of photorefractive keratectomy

    Science.gov (United States)

    Della Vecchia, Michael A.; Lamkin-Kennard, Kathleen

    1997-05-01

    Procedurally, excimer photorefractive keratectomy is based on the refractive correction of composite spherical and cylindrical ophthalmic errors of the entire eye. These refractive errors are inputted for correction at the corneal plane and for the properly controlled duration and location of laser energy. Topography is usually taken to correspondingly monitor spherical and cylindrical corneorefractive errors. While a corneal topographer provides surface morphologic information, the keratorefractive photoablation is based on the patient's spherical and cylindrical spectacle correction. Topography is at present not directly part of the procedural deterministic parameters. Examination of how corneal curvature at each of the keratometric reference loci affect the shape of the resultant corneal photoablated surface may enhance the accuracy of the desired correction. The objective of this study was to develop a methodology to utilize corneal topography for construction of models depicting pre- and post-operative keratomorphology for analysis of photorefractive keratectomy. Multiple types of models were developed then recreated in optical design software for examination of focal lengths and other optical characteristics. The corneal models were developed using data extracted from the TMS I corneal modeling system (Computed Anatomy, New York, NY). The TMS I does not allow for manipulation of data or differentiation of pre- and post-operative surfaces within its platform, thus models needed to be created for analysis. The data were imported into Matlab where 3D models, surface meshes, and contour plots were created. The data used to generate the models were pre- and post-operative curvatures, heights from the corneal apes, and x-y positions at 6400 locations on the corneal surface. Outlying non-contributory points were eliminated through statistical operations. Pre- and post- operative models were analyzed to obtain the resultant changes in the corneal surfaces during PRK

  2. The New Zealand National Eye Bank study: trends in the acquisition and storage of corneal tissue over the decade 2000 to 2009.

    Science.gov (United States)

    Cunningham, William J; Moffatt, S Louise; Brookes, Nigel H; Twohill, Helen C; Pendergrast, David G C; Stewart, Joanna M; McGhee, Charles N J

    2012-05-01

    To evaluate trends in the acquisition, storage, and utilization of donated corneal tissue in New Zealand, 2000 to 2009. The New Zealand National Eye Bank records were analyzed for the decade January 2000 to December 2009. Variables analyzed included donor demographics (age, sex, and ethnicity), donor source, donor cause of death, death-to-preservation interval (DPI), corneal storage time, tissue contamination, endothelial assessment, cornea suitability for transplantation, and corneal tissue utilization. A total of 1268 eye donors were identified during the 10-year period. Overall, 36% (n = 457) were female and 64% male (n = 813). Median donor age was 67 years, and 23% of donors were younger than 50 years (range, 5-90 years). There was a decrease in donor age over the decade (P = 0.006). The median DPI was 18.5 hours. No relationship was identified between cornea suitability for transplantation and DPI (P = 0.28) or donor gender (P = 0.54). There was a low microbial contamination rate (1%). Human immunodeficiency virus, hepatitis B, or hepatitis C serology was positive in 48 donors (4%). Overall, 90% of corneas were suitable for transplantation with a high utilization rate (88%). A novel association was identified between male sex and lower corneal endothelial cell density (P = 0.03). This New Zealand National Eye Bank analysis identified trends in the acquisition, storage, and utilization of donated corneal tissue throughout New Zealand over the past decade and provides valuable additional information to the international eye bank data.

  3. [Clinical pilot study to evaluate the efficacy of a preservative-free hypertonic ophthalmic solution for patients with symptomatic corneal edema].

    Science.gov (United States)

    Rouland, J-F

    2015-11-01

    This exploratory clinical trial aims to assess the effect on visual acuity and central corneal thickness of an unpreserved hypertonic ophthalmic solution containing sodium chloride (5%) and sodium hyaluronate, in patients with chronic corneal edema caused by endothelial disease reducing their visual acuity. Twenty patients were enrolled and treated with the hypertonic solution (1 to 2 drops per eye, 4 times a day over 28 days). Progression of visual acuity (ETDRS score) and corneal thickness (ultrasonic pachymetry) was measured from baseline (without treatment) through the treatment period (Day 7 and Day 28). The analyses were performed on 18 patients (Full Analysis Set [FAS] population). The causes of corneal edema were Fuchs endothelial dystrophy in 10 cases and post-cataract surgery endothelial decompensation in 8 patients. The mean visual acuity values for the FAS population compared between baseline (Day-7) and one week of treatment (Day+7) show a significant 5-point VA improvement (Psolution containing sodium chloride and sodium hyaluronate significantly improved ETDRS visual acuity after one week of use. In this clinical trial, the solution also showed excellent tolerability results. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. Alloimmunity and Tolerance in Corneal Transplantation.

    Science.gov (United States)

    Amouzegar, Afsaneh; Chauhan, Sunil K; Dana, Reza

    2016-05-15

    Corneal transplantation is one of the most prevalent and successful forms of solid tissue transplantation. Despite favorable outcomes, immune-mediated graft rejection remains the major cause of corneal allograft failure. Although low-risk graft recipients with uninflamed graft beds enjoy a success rate ∼90%, the rejection rates in inflamed graft beds or high-risk recipients often exceed 50%, despite maximal immune suppression. In this review, we discuss the critical facets of corneal alloimmunity, including immune and angiogenic privilege, mechanisms of allosensitization, cellular and molecular mediators of graft rejection, and allotolerance induction. Copyright © 2016 by The American Association of Immunologists, Inc.

  5. Corneal iron ring after hyperopic photorefractive keratectomy.

    Science.gov (United States)

    Bilgihan, K; Akata, F; Gürelik, G; Adigüzel, U; Akpinar, M; Hasanreisoğlu, B

    1999-05-01

    To report the incidence and course of corneal iron deposition after hyperopic photorefractive keratectomy (PRK). Gazi University, Medical School, Department of Ophthalmology, Ankara, Turkey. Between January 1995 and December 1997, 62 eyes had PRK to correct hyperopia. Nine eyes developed corneal iron ring 5 to 8 months (mean 6.25 months +/- 1.3 [SD]) after PRK for hyperopia. The rings persisted during the mean follow-up of 19 +/- 11.09 months. The ring-shaped iron deposition after PRK for hyperopia must be differentiated from the Fleischer ring. Our results suggest that the slitlamp findings of peripheral corneal iron deposition in hyperopic PRK patients correlate with achieved correction.

  6. Applications of corneal topography and tomography: a review.

    Science.gov (United States)

    Fan, Rachel; Chan, Tommy Cy; Prakash, Gaurav; Jhanji, Vishal

    2018-03-01

    Corneal imaging is essential for diagnosing and management of a wide variety of ocular diseases. Corneal topography is used to characterize the shape of the cornea, specifically, the anterior surface of the cornea. Most corneal topographical systems are based on Placido disc that analyse rings that are reflected off the corneal surface. The posterior corneal surface cannot be characterized using Placido disc technology. Imaging of the posterior corneal surface is useful for diagnosis of corneal ectasia. Unlike corneal topographers, tomographers generate a three-dimensional recreation of the anterior segment and provide information about the corneal thickness. Scheimpflug imaging is one of the most commonly used techniques for corneal tomography. The cross-sectional images generated by a rotating Scheimpflug camera are used to locate the anterior and posterior corneal surfaces. The clinical uses of corneal topography include, diagnosis of corneal ectasia, assessment of corneal astigmatism, and refractive surgery planning. This review will discuss the applications of corneal topography and tomography in clinical practice. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  7. Generation of Corneal Keratocytes from Human Embryonic Stem Cells.

    Science.gov (United States)

    Hertsenberg, Andrew J; Funderburgh, James L

    2016-01-01

    Human Embryonic Stem Cells (hESC) offer an important resource as a limitless supply of any differentiated cell type of the human body. Keratocytes, cells from the corneal stroma, may have the potential for restoration of vision in cell therapy and biomedical engineering applications, but these specialized cells are not readily expanded in vitro. Here we describe a two-part method to produce keratocytes from the H1 hESC cell line. The hESC cells, maintained and expanded in feeder-free culture medium are first differentiated to neural crest cells using the stromal-derived inducing activity (SDIA) of the PA6 mouse embryonic fibroblast cell line. The resulting neural crest cells are selected by their expression of cell-surface CD271 and subsequently cultured as 3D pellets in a defined differentiation medium to induce a keratocyte phenotype.

  8. Effect of chemical composition on corneal tissue response to photopolymerized materials comprising 2-hydroxyethyl methacrylate and acrylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Jui-Yang, E-mail: jylai@mail.cgu.edu.tw

    2014-01-01

    The purpose of this work was to investigate the relationship between the feed composition of 2-hydroxyethyl methacrylate (HEMA)/acrylic acid (AAc) and hydrogel material compatibility towards ocular anterior segment tissues, particularly the corneal endothelium. The monomer solutions of HEMA and AAc were mixed at varying volume ratios of 92:0, 87:5, 82:10, 77:15, and 72:20, and were subjected to UV irradiation. Then, the 7-mm-diameter membrane implants made from photopolymerized materials were placed into the ocular anterior chamber for 4 days and assessed by biomicroscopic examinations, corneal thickness measurements, and quantitative real-time reverse transcription polymerase chain reaction analyses. The poly(HEMA-co-AAc) implants prepared from the solution mixture containing 0–10 vol.% AAc displayed good biocompatibility. However, with increasing volume ratio of AAc and HEMA from 15:77 to 20:72, the enhanced inflammatory response, decreased endothelial cell density, and increased ocular score and corneal thickness were observed, probably due to the influence of surface charge of copolymer membranes. On the other hand, the ionic pump function of corneal endothelium exposed to photopolymerized membranes was examined by analyzing the Na{sup +},K{sup +}-ATPase alpha 1 subunit (ATP1A1) expression level. The presence of the implants having higher amount of AAc incorporated in the copolymers (i.e., 15.1 to 24.7 μmol) and zeta potential (i.e., -38.6 to − 56.5 mV) may lead to abnormal transmembrane transport. It is concluded that the chemical composition of HEMA/AAc has an important influence on the corneal tissue responses to polymeric biomaterials. - Highlights: • We examine the corneal tissue responses to photopolymerized biomaterials. • Carboxyl groups in copolymers increased with increasing volume ratio of AAc/HEMA. • 15–20 vol.% AAc raised ocular score and caused corneal endothelial loss and edema. • High anionic charge density stimulated inflammation

  9. Central corneal thickness among glaucoma patients attending ...

    African Journals Online (AJOL)

    AAU_CHS

    ocular pressure measurement and is different among different ethnic population and subtypes of glaucoma. The central corneal thickness of different subtypes of glaucoma at Menelik II Hospital ... Intraocular pressure is a key element in the.

  10. Celastrol nanoparticles inhibit corneal neovascularization induced by suturing in rats

    Directory of Open Access Journals (Sweden)

    Li ZR

    2012-03-01

    Full Text Available Zhanrong Li1, Lin Yao1, Jingguo Li2, Wenxin Zhang1, Xianghua Wu1, Yi Liu1, Miaoli Lin1, Wenru Su1, Yongping Li1, Dan Liang11State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, 2School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou, People's Republic of ChinaPurpose: Celastrol, a traditional Chinese medicine, is widely used in anti-inflammation and anti-angiogenesis research. However, the poor water solubility of celastrol restricts its further application. This paper aims to study the effect of celastrol nanoparticles (CNPs on corneal neovascularization (CNV and determine the possible mechanism.Methods: To improve the hydrophilicity of celastrol, celastrol-loaded poly(ethylene glycol-block-poly(ε-caprolactone nanopolymeric micelles were developed. The characterization of CNPs was measured by dynamic light scattering and transmission electron microscopy analysis. Celastrol loading content and release were assessed by ultraviolet-visible analysis and high performance liquid chromatography, respectively. In vitro, human umbilical vein endothelial cell proliferation and capillary-like tube formation were assayed. In vivo, suture-induced CNV was chosen to evaluate the effect of CNPs on CNV in rats. Immunohistochemistry for CD68 assessed the macrophage infiltration of the cornea on day 6 after surgery. Real-time quantitative reverse transcription-polymerase chain reaction and enzyme-linked immunosorbent assay were used to evaluate the messenger ribonucleic acid and protein levels, respectively, of vascular endothelial growth factor, matrix metalloproteinase 9, and monocyte chemoattractant protein 1 in the cornea.Results: The mean diameter of CNPs with spherical shape was 48 nm. The celastrol loading content was 7.36%. The release behavior of CNPs in buffered solution (pH 7.4 showed a typical two-phase release profile. CNPs inhibited the proliferation of human umbilical vein endothelial

  11. Risk factors for corneal ectasia after LASIK.

    Science.gov (United States)

    Tabbara, Khalid F; Kotb, Amgad A

    2006-09-01

    To establish a grading system that helps identify high-risk individuals who may experience corneal ectasia after LASIK. Retrospective, comparative, interventional case series. One hundred forty-eight consecutive patients (148 eyes) were included in this study. Thirty-seven patients who underwent LASIK at other refractive centers experienced corneal ectasia in 1 eye after LASIK. One hundred eleven eyes of 111 patients who underwent successful LASIK during the same period were age and gender matched and served as controls. All patients underwent preoperative and postoperative topographic analysis of the cornea. The follow-up period in both groups of patients ranged from 2 to 5 years, with a mean follow-up of 3.6 years. All patients underwent LASIK for myopia (spherical equivalent, -4.00 to -8.00 diopters). Corneal keratometry, oblique cylinder, pachymetry, posterior surface elevation, difference between the inferior and superior corneal diopteric power, and posterior best sphere fit (BSF) over anterior BSF were given a grade of 1 to 3 each. An ectasia grading system was established, and the cumulative risk score was assessed. Patients who had a grade of 7 or less showed no evidence of corneal ectasia, whereas 16 (59%) of 27 patients who had a grade of 8 to 12 had corneal ectasia. Twenty-one (100%) of 21 patients with a grade of more than 12 had corneal ectasia after LASIK (P<0.0001). A risk score may help in the prediction of patients who are at risk of experiencing corneal ectasia after LASIK. A prospective clinical study is needed to assess the validity of these risk factors.

  12. Healed corneal ulcer with keloid formation

    OpenAIRE

    Alkatan, Hind M.; Al-Arfaj, Khalid M.; Hantera, Mohammed; Al-Kharashi, Soliman

    2012-01-01

    We are reporting a 34-year-old Arabic white female patient who presented with a white mass covering her left cornea following multiple ocular surgeries and healed corneal ulcer. The lesion obscured further view of the iris, pupil and lens. The patient underwent penetrating keratoplasty and the histopathologic study of the left corneal button showed epithelial hyperplasia, absent Bowman’s layer and subepithelial fibrovascular proliferation. The histopathologic appearance was suggestive of a co...

  13. Corneal elastosis within lattice dystrophy lesions.

    Science.gov (United States)

    Pe'er, J; Fine, B S; Dixon, A; Rothberg, D S

    1988-01-01

    Corneal buttons of two patients with lattice corneal dystrophy were studied by light and electron microscopy. They showed elastotic degeneration within the amyloid deposits. The amyloid deposits displayed characteristic staining; the elastotic material (elastin) within the deposits stained positive with Verhoeff-van Gieson and Movat pentachrome stains and showed autofluorescence. The characteristic ultrastructural findings of amyloid and elastotic material were also demonstrated. The possibility of the associations of these two materials in the cornea is discussed. Images PMID:3258531

  14. Intraocular pressure, corneal thickness, and corneal hysteresis in Steinert's myotonic dystrophy

    Directory of Open Access Journals (Sweden)

    Carlos Alexandre de A. Garcia Filho

    2011-06-01

    Full Text Available PURPOSE: Low intraocular pressure (IOP measured by Goldmann applanation tonometry (GAT is one of the ocular manifestations of Steinert's myotonic dystrophy. The goal of this study was to evaluate the corneal-compensated IOP as well as corneal properties (central corneal thickness and corneal hysteresis in patients with myotonic dystrophy. METHODS: A total of 12 eyes of 6 patients with Steinert's myotonic dystrophy (dystrophy group and 12 eyes of 6 age-, race-, and gender-matched healthy volunteers (control group were included in the study. GAT, Dynamic Contour Tonometry (DCT-Pascal and Ocular Response Analyzer (ORA were used to assess the IOP. Central corneal thickness was obtained by ultrasound pachymetry, and corneal hysteresis was analyzed using the ORA device. In light of the multiplicity of tests performed, the significance level was set at 0.01 rather than 0.05. RESULTS: The mean (standard deviation [SD] GAT, DCT, and corneal-compensated ORA IOP in the dystrophy group were 5.4 (1.4 mmHg, 9.7 (1.5 mmHg, and 10.1 (2.6 mmHg, respectively. The mean (SD GAT, DCT, and corneal-compensated ORA IOP in the control group was 12.6 (2.9 mmHg, 15.5 (2.7 mmHg, and 15.8 (3.4 mmHg, respectively. There were significant differences in IOP values between dystrophy and control groups obtained by GAT (mean, -7.2 mmHg; 99% confidence interval [CI], -10.5 to -3.9 mmHg; P<0.001, DCT (mean, -5.9 mmHg; 99% CI, -8.9 to -2.8 mmHg; P<0.001, and corneal-compensated ORA measurements (mean, -5.7 mmHg; 99% CI, -10.4 to -1.0 mmHg; P=0.003. The mean (SD central corneal thickness was similar in the dystrophy (542 [31] µm and control (537 [11] µm groups (P=0.65. The mean (SD corneal hysteresis in the dystrophy and control groups were 11.2 (1.5 mmHg and 9.7 (1.2 mmHg, respectively (P=0.04. CONCLUSIONS: Patients with Steinert's myotonic dystrophy showed lower Goldmann and corneal-compensated IOP in comparison with healthy individuals. Since central corneal thickness and

  15. Corneal refractive index-hydration relationship by objective refractometry.

    Science.gov (United States)

    Patel, Sudi; Alió, Jorge L

    2012-11-01

    To compare an objective (VCH-1) with a manual subjective Abbé refractometer (MSAR) and evaluate the refractive index (RI)-hydration (H) relationship for the corneal stroma. Epithelial and endothelial layers were removed from a fresh postmortem ovine corneal buttons. RI was measured at both surfaces using (i) MSAR then (ii) VCH-1. The sample was weighed, slowly dehydrated under controlled conditions (2 h), and RI measures were repeated. Sample was oven dried (90°C) for 3 d to obtain dry weight and hydration at each episode of RI measurement. Average difference between individual pairs of measurements obtained using the two refractometers (ΔRI) was 0.00071 (standard deviation ± 0.0029, 95% confidence interval ± 0.0058). Root mean square difference between measurements obtained by the refractometers was 0.0024. There was no relationship between ΔRI and the mean of each measurement pair (r = 0.201, n = 40, p = 0.214). Linear regression revealed a significant relationship between RI and reciprocal of H at both surfaces as follows: anterior (i) RI = 1.355 + 0.111/H (r = -0.852, n = 20, p = <0.001), (ii) RI = 1.357 + 0.105/H (r = -0.849, n = 20, p = <0.001) and posterior (i) RI = 1.353 + 0.085/H (r = -0.882, n = 20, p = <0.001), (ii) RI = 1.350 + 0.088/H (r = -0.813, n = 20, p = <0.001). VCH-1 measurements are in good agreement with MSAR. RI at the anterior stroma was consistently higher suggesting hydration is lower by 1.10 units (6%) compared with the posterior stroma. Dehydration increased RI at both surfaces by similar rates. Current hypothetical models are useful for predicting RI from H for the posterior, but not the anterior, stroma.

  16. An “All-laser” Endothelial Transplant

    Science.gov (United States)

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-01-01

    The “all laser” assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event. PMID:26167711

  17. An "All-laser" Endothelial Transplant.

    Science.gov (United States)

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-07-06

    The "all laser" assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event.

  18. Optical Coherence Tomography Examination of the Anterior Segment in a Case of Corneal Perforation and Lens Trauma by Chestnut Burr

    Directory of Open Access Journals (Sweden)

    Takashi Ono

    2018-02-01

    Full Text Available Chestnut burrs, the thorny encapsulation of chestnut fruit, can sometimes cause corneal injuries and ulceration, with poor prognoses. We report a case of corneal perforation and damaged anterior lens capsule due to a chestnut burr, using anterior segment optical coherence tomography (AS-OCT. A 67-year-old woman with a chestnut burr injury in her right eye was referred to our hospital. Her right best-corrected visual acuity (BCVA was 0.8. Slit-lamp examination and AS-OCT showed perforation involving the endothelial layer at the center of the cornea. The iris and anterior lens capsule were damaged. Cell infiltration was observed around the wound. Bacterial examination showed gram-positive cocci but no fungi. The patient was diagnosed with a corneal perforation and bacterial keratitis. Levofloxacin 1.5% and cefmenoxime treatments were initiated and a soft contact lens was placed to seal the wound. On day 3, there was no improvement in the corneal cell infiltration, but AS-OCT suggested that the inner wound had closed. A culture test revealed the presence of Propionibacterium acnes, which was sensitive to both levofloxacin and cefmenoxime. Therefore, we continued the same antibiotic treatment. On day 26, the opacification and cell infiltration at the center of the cornea had improved. AS-OCT showed healing of the corneal wound with reduction in the central corneal thickness. Her BCVA improved to 1.0. AS-OCT was a valuable tool to noninvasively observe wound shape and detect the presence of any intracorneal foreign bodies.

  19. Glutaminolysis is Essential for Energy Production and Ion Transport in Human Corneal Endothelium

    Directory of Open Access Journals (Sweden)

    Wenlin Zhang

    2017-02-01

    Full Text Available Corneal endothelium (CE is among the most metabolically active tissues in the body. This elevated metabolic rate helps the CE maintain corneal transparency by its ion and fluid transport properties, which when disrupted, leads to visual impairment. Here we demonstrate that glutamine catabolism (glutaminolysis through TCA cycle generates a large fraction of the ATP needed to maintain CE function, and this glutaminolysis is severely disrupted in cells deficient in NH3:H+ cotransporter Solute Carrier Family 4 Member 11 (SLC4A11. Considering SLC4A11 mutations leads to corneal endothelial dystrophy and sensorineural deafness, our results indicate that SLC4A11-associated developmental and degenerative disorders result from altered glutamine catabolism. Overall, our results describe an important metabolic mechanism that provides CE cells with the energy required to maintain high level transport activity, reveal a direct link between glutamine metabolism and developmental and degenerative neuronal diseases, and suggest an approach for protecting the CE during ophthalmic surgeries.

  20. In vitro effects of three blood derivatives on human corneal epithelial cells.

    Science.gov (United States)

    Freire, Vanesa; Andollo, Noelia; Etxebarria, Jaime; Durán, Juan A; Morales, María-Celia

    2012-08-15

    We compared the effects of three blood derivatives, autologous serum (AS), platelet-rich plasma (PRP), and serum derived from plasma rich in growth factors (PRGF), on a human corneal epithelial (HCE) cell line to evaluate their potential as an effective treatment for corneal epithelial disorders. The concentrations of epidermal growth factor (EGF), fibroblast growth factor (FGF), vascular endothelial growth factor (VEGF), hepatocyte growth factor (HGF), platelet-derived growth factor (PDGF), and fibronectin were quantified by ELISA. The proliferation and viability of HCE cells were measured by an 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) colorimetric assay. Cell morphology was assessed by phase-contrast microscopy. The patterns of expression of several connexin, involucrin, and integrin α6 genes were analyzed by real-time RT-PCR. We found significantly higher levels of EGF in PRGF compared to AS and PRP. However, AS and PRGF induced robust proliferation of HCE cells. In addition, PRGF cultured cells grew as heterogeneous colonies, exhibiting differentiated and non-differentiated cell phenotypes, whereas AS- and PRP-treated cultures exhibited quite homogeneous colonies. Finally, PRGF upregulated the expression of several genes associated with communication and cell differentiation, in comparison to AS or PRP. PRGF promotes biological processes required for corneal epithelialization, such as proliferation and differentiation. Since PRGF effects are similar to those associated with routinely used blood derivatives, the present findings warrant further research on PRGF as a novel alternative treatment for ocular surface diseases.

  1. Instillation of Sericin Enhances Corneal Wound Healing through the ERK Pathway in Rat Debrided Corneal Epithelium

    Directory of Open Access Journals (Sweden)

    Noriaki Nagai

    2018-04-01

    Full Text Available Sericin is a major constituent of silk produced by silkworms. We previously found that the instillation of sericin enhanced the proliferation of corneal epithelial cells, and acted to promote corneal wound healing in both normal and diabetic model rats. However, the mechanisms by which sericin promotes the proliferation of corneal cells have not been established. In this study, we investigated the effects of sericin on Akt and ERK activation in a human corneal epithelial cell line (HCE-T cells and rat debrided corneal epithelium. Although Akt phosphorylation was not detected following the treatment of HCE-T cells with sericin, ERK1/2 phosphorylation was enhanced. The growth of HCE-T cells treated with sericin was significantly increased, with the cell growth of sericin-treated HCE-T cells being 1.7-fold higher in comparison with vehicle-treated HCE-T cells. On the other hand, both of an ERK inhibitor U0126 (non-specific specific inhibitor and SCH772984 (specific inhibitor attenuated the enhanced cell growth by sericin, and the growth level in the case of co-treatment with sericin and ERK1/2 inhibitor was similar to that of cells treated with ERK1/2 inhibitor alone. In an in vivo study using rat debrided corneal epithelium, the corneal wound healing rate was enhanced by the instillation of sericin, and this enhancement was also attenuated by the instillation of U0126. In addition, the corneal wound healing rate in rats co-instilled with sericin and U0126 was similar to that following the instillation of U0126 alone. In conclusion, we found that the instillation of sericin enhanced cell proliferation via the activation of the MAPK/ERK pathway, resulting in the promotion of corneal wound healing in rat eyes. These findings provide significant information for designing further studies to develop potent corneal wound-healing drugs.

  2. Topographic characteristics after Descemet's membrane endothelial keratoplasty and Descemet's stripping automated endothelial keratoplasty.

    Directory of Open Access Journals (Sweden)

    Takahiko Hayashi

    Full Text Available To investigate the topographic characteristics of the posterior corneal surface after Descemet's endothelial membrane keratoplasty (DMEK and Descemet's stripping automated endothelial keratoplasty (DSAEK and their effects on postoperative visual acuity.Nineteen eyes of 19 patients after DMEK, 23 eyes of 23 patients after DSAEK, and 18 eyes of 18 control subjects were retrospectively analyzed. Best spectacle-corrected visual acuity (BSCVA, aberration factors (higher-order aberrations [HOAs], spherical aberrations [SAs], and coma aberrations [Comas] at 6.0 mm were evaluated preoperatively and at 1, 3, and 6 months postoperatively. The posterior refractive pattern of the topography map was classified into 5 grades (0-5 (posterior color grade using anterior segment optical coherence tomography. Correlations between BSCVA and some factors (abbreviation factors, posterior color grade were analyzed.BSCVA was significantly better after DMEK than after DSAEK (P < 0.001. Posterior HOAs, SAs, and Comas after each type of endothelial keratoplasty were significantly greater compared to control (P < 0.01. Posterior HOAs, total/anterior/posterior SAs, and posterior color grade were significantly lower in the DMEK group than in the DSAEK group at 3 months (P < 0.024 [posterior HOAs], P = 0.047 [total SA], P < 0.001 [anterior SAs], P = 0.021 [posterior SAs], and P < 0.001 [posterior color grade] and 6 months postoperatively (P = 0.034 [posterior HOAs], P < 0.001 [total SAs], P < 0.001 [anterior SAs], P = 0.013 [posterior SAs], and P = 0.004 [posterior color grade]. BSCVA was significantly correlated with HOAs, SAs, and posterior color grade (P < 0.001 for all except anterior HOAs [P = 0.004].High posterior color grades were associated with larger aberration factors and had a negative effect on visual function after endothelial keratoplasty. Rapid improvement of visual function after DMEK may be attributed to less change at the posterior surface.

  3. Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    The purpose of this project was to determine the role of corneal implants in the management of corneal thinning disease conditions. An evidence-based review was conducted to determine the safety, effectiveness and durability of corneal implants for the management of corneal thinning disorders. The evolving directions of research in this area were also reviewed. SUBJECT OF THE EVIDENCE-BASED ANALYSIS: The primary treatment objectives for corneal implants are to normalize corneal surface topography, improve contact lens tolerability, and restore visual acuity in order to delay or defer the need for corneal transplant. Implant placement is a minimally invasive procedure that is purported to be safe and effective. The procedure is also claimed to be adjustable, reversible, and both eyes can be treated at the same time. Further, implants do not limit the performance of subsequent surgical approaches or interfere with corneal transplant. The evidence for these claims is the focus of this review. The specific research questions for the evidence review were as follows: SafetyCorneal Surface Topographic Effects:Effects on corneal surface remodellingImpact of these changes on subsequent interventions, particularly corneal transplantation (penetrating keratoplasty [PKP])Visual AcuityRefractive OutcomesVISUAL QUALITY (SYMPTOMS): such as contrast vision or decreased visual symptoms (halos, fluctuating vision)Contact lens toleranceFunctional visual rehabilitation and quality of lifePatient satisfaction:Disease Process:Impact on corneal thinning processEffect on delaying or deferring the need for corneal transplantation TARGET POPULATION AND CONDITION Corneal ectasia (thinning) comprises a range of disorders involving either primary disease conditions such as keratoconus and pellucid marginal corneal degeneration or secondary iatrogenic conditions such as corneal thinning occurring after LASIK refractive surgery. The condition occurs when the normally round dome-shaped cornea

  4. Role of glutathione biosynthesis in endothelial dysfunction and fibrosis

    Directory of Open Access Journals (Sweden)

    Cristina Espinosa-Díez

    2018-04-01

    Full Text Available Glutathione (GSH biosynthesis is essential for cellular redox homeostasis and antioxidant defense. The rate-limiting step requires glutamate-cysteine ligase (GCL, which is composed of the catalytic (GCLc and the modulatory (GCLm subunits. To evaluate the contribution of GCLc to endothelial function we generated an endothelial-specific Gclc haplo-insufficient mouse model (Gclc e/+ mice. In murine lung endothelial cells (MLEC derived from these mice we observed a 50% reduction in GCLc levels compared to lung fibroblasts from the same mice. MLEC obtained from haplo-insufficient mice showed significant reduction in GSH levels as well as increased basal and stimulated ROS levels, reduced phosphorylation of eNOS (Ser 1177 and increased eNOS S-glutathionylation, compared to MLEC from wild type (WT mice. Studies in mesenteric arteries demonstrated impaired endothelium-dependent vasodilation in Gclc(e/+ male mice, which was corrected by pre-incubation with GSH-ethyl-ester and BH4. To study the contribution of endothelial GSH synthesis to renal fibrosis we employed the unilateral ureteral obstruction model in WT and Gclc(e/+ mice. We observed that obstructed kidneys from Gclc(e/+ mice exhibited increased deposition of fibrotic markers and reduced Nrf2 levels. We conclude that the preservation of endothelial GSH biosynthesis is not only critical for endothelial function but also in anti-fibrotic responses. Keywords: Glutamate-cysteine ligase, ROS, Glutathione, Endothelial dysfunction, Kidney Fibrosis

  5. Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae

    Directory of Open Access Journals (Sweden)

    Gustavo Victor

    2014-04-01

    Full Text Available Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500µm. The laser cuts were made using an LDV® femtosecond laser in a Ziemer® anterior chamber. To obtain a better edge, the lamellae were trephined with an 8mm trephine (Katena®. The central corneal thickness and the anterior lamellae were measured using a Mitutoyo® thickness gauge with an accuracy of 0.001mm. Results: The central thickness of the 25 corneas ranged from 500 to 705µm (mean, 584 ± 51µm. The thickness of the anterior lamellae ranged from 420 to 480µm (mean, 455 ± 12.7µm. The anterior lamellae diameters were 7.90 ± 0.1mm, and all laser cuts were round. The lamellar interfaces appeared regular by surgical microscopy. There were no cases of inter-lamellar adhesion. Conclusion: The LDV® femtosecond laser appears to be a safe and reliable instrument for cutting deep anterior lamellae from donor corneoscleral buttons. Minimal variation in donor lamellar depth with the laser will be useful for creating donor corneal tissue for deeper anterior lamellar keratoplasty or endothelial keratoplasty surgery or both from a single donor cornea.

  6. Biodegradable and biocompatible poly(ethylene glycol)-based hydrogel films for the regeneration of corneal endothelium.

    Science.gov (United States)

    Ozcelik, Berkay; Brown, Karl D; Blencowe, Anton; Ladewig, Katharina; Stevens, Geoffrey W; Scheerlinck, Jean-Pierre Y; Abberton, Keren; Daniell, Mark; Qiao, Greg G

    2014-09-01

    Corneal endothelial cells (CECs) are responsible for maintaining the transparency of the human cornea. Loss of CECs results in blindness, requiring corneal transplantation. In this study, fabrication of biocompatible and biodegradable poly(ethylene glycol) (PEG)-based hydrogel films (PHFs) for the regeneration and transplantation of CECs is described. The 50-μm thin hydrogel films have similar or greater tensile strengths to human corneal tissue. Light transmission studies reveal that the films are >98% optically transparent, while in vitro degradation studies demonstrate their biodegradation characteristics. Cell culture studies demonstrate the regeneration of sheep corneal endothelium on the PHFs. Although sheep CECs do not regenerate in vivo, these cells proliferate on the films with natural morphology and become 100% confluent within 7 d. Implantation of the PHFs into live sheep corneas demonstrates the robustness of the films for surgical purposes. Regular slit lamp examinations and histology of the cornea after 28 d following surgery reveal minimal inflammatory responses and no toxicity, indicating that the films are benign. The results of this study suggest that PHFs are excellent candidates as platforms for the regeneration and transplantation of CECs as a result of their favorable biocompatibility, degradability, mechanical, and optical properties. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The inhibitory effect of different concentrations of KH902 eye drops on corneal neovascularization induced by alkali burn

    Directory of Open Access Journals (Sweden)

    Yan Wu

    2017-01-01

    Full Text Available Purpose: The aim of this study was to evaluate the inhibitory effect of different concentrations of KH902 eye drops on rabbit corneal neovascularization (CNV induced by alkali burn. Methods: Forty-eight adult rabbits were randomized into four groups after alkali burning: Group A (2.5 mg/ml, Group B (5 mg/ml, and Group C (10 mg/ml by different concentrations of KH902 eye drops and Group D by saline solution as control with three times a day for 2 weeks. At days 7, 14, and 28, the anterior segment photographs, confocal microscopy, and histopathology were performed to evaluate corneal opacity, neovascularization, inflammatory cell density, vessel size, and edema. Immunohistochemistry was applied to analyze the vascular endothelial growth factor (VEGF level. Results: (1 The CNV in the medicine-treated groups showed a reduction without obvious corneal side effects histologically. (2 Compared to the control group, the three medicine-treated groups showed a reduction in the VEGF levels and CNV areas on days 7, 14, and 28 and in the inflammatory cell density on days 14 and 28 (P 0.05. Conclusion: KH902 eye drops in lower concentration showed an obvious reduction of the CNV growing for rabbit corneal alkali burn without side effects.

  8. Prevalence and causes of corneal blindness.

    Science.gov (United States)

    Wang, Haijing; Zhang, Yaoguang; Li, Zhijian; Wang, Tiebin; Liu, Ping

    2014-04-01

    The study aimed to assess the prevalence and causes of corneal blindness in a rural northern Chinese population. Cross-sectional study. The cluster random sampling method was used to select the sample. This population-based study included 11 787 participants of all ages in rural Heilongjiang Province, China. These participants underwent a detailed interview and eye examination that included the measurement of visual acuity, slit-lamp biomicroscopy and direct ophthalmoscopy. An eye was considered to have corneal blindness if the visual acuity was blindness and low vision. Among the 10 384 people enrolled in the study, the prevalence of corneal blindness is 0.3% (95% confidence interval 0.2-0.4%). The leading cause was keratitis in childhood (40.0%), followed by ocular trauma (33.3%) and keratitis in adulthood (20.0%). Age and illiteracy were found to be associated with an increased prevalence of corneal blindness. Blindness because of corneal diseases in rural areas of Northern China is a significant public health problem that needs to be given more attention. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  9. Riboflavin for corneal cross-linking.

    Science.gov (United States)

    O'Brart, D P S

    2016-06-01

    Corneal collagen cross-linking (CXL) with riboflavin and ultraviolet A (UVA) radiation is the first therapeutic modality that appears to arrest the progression of keratoconus and other corneal ectasias. Riboflavin is central to the process, acting as a photosensitizer for the production of oxygen singlets and riboflavin triplets. These free radicals drive the CXL process within the proteins of the corneal stroma, altering its biomechanical properties. Riboflavin also absorbs the majority of the UVA radiation, which is potentially cytotoxic and mutagenic, within the anterior stroma, preventing damage to internal ocular structures, such as the corneal endothelium, lens and retina. Clinical studies report cessation of ectatic progression in over 90% of cases and the majority document significant improvements in visual, keratometric and topographic parameters. Clinical follow-up is limited to 5-10 years, but suggests sustained stability and enhancement in corneal shape. Sight-threatening complications are rare. The optimal stromal riboflavin dosage for CXL is as yet undetermined. Copyright 2016 Prous Science, S.A.U. or its licensors. All rights reserved.

  10. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  11. Interface Fluid Syndrome After Laser In Situ Keratomileusis (LASIK) Because of Fuchs Endothelial Dystrophy Reversed by Descemet Membrane Endothelial Keratoplasty (DMEK).

    Science.gov (United States)

    Luceri, Salvatore; Baksoellah, Zainab; Ilyas, Abbas; Baydoun, Lamis; Melles, Gerrit R J

    2016-12-01

    To describe a case that developed "interface fluid syndrome" after previous laser in situ keratomileusis (LASIK) because of Fuchs endothelial dystrophy (FED), which was reversed by Descemet membrane endothelial keratoplasty (DMEK). A 58-year-old male patient presented with bilateral visual impairment owing to FED and visually significant cataract. Cataract surgery was carried out in both eyes followed by DMEK in his left eye. After cataract surgery, visual acuity did not improve sufficiently because corneal thickness increased and a fine cleft with interface fluid developed between the LASIK-flap and the residual stromal bed. After uneventful DMEK in his left eye, the fluid resolved within a week and visual acuity improved rapidly. This case demonstrates that "interface fluid syndrome" after LASIK caused by concomitant endothelial dysfunction may be reversed by DMEK allowing fast visual recovery.

  12. Laminar shear stress modulates endothelial luminal surface stiffness in a tissue-specific manner.

    Science.gov (United States)

    Merna, Nick; Wong, Andrew K; Barahona, Victor; Llanos, Pierre; Kunar, Balvir; Palikuqi, Brisa; Ginsberg, Michael; Rafii, Shahin; Rabbany, Sina Y

    2018-04-17

    Endothelial cells form vascular beds in all organs and are exposed to a range of mechanical forces that regulate cellular phenotype. We sought to determine the role of endothelial luminal surface stiffness in tissue-specific mechanotransduction of laminar shear stress in microvascular mouse cells and the role of arachidonic acid in mediating this response. Microvascular mouse endothelial cells were subjected to laminar shear stress at 4 dynes/cm 2 for 12 hours in parallel plate flow chambers that enabled real-time optical microscopy and atomic force microscopy measurements of cell stiffness. Lung endothelial cells aligned parallel to flow, while cardiac endothelial cells did not. This rapid alignment was accompanied by increased cell stiffness. The addition of arachidonic acid to cardiac endothelial cells increased alignment and stiffness in response to shear stress. Inhibition of arachidonic acid in lung endothelial cells and embryonic stem cell-derived endothelial cells prevented cellular alignment and decreased cell stiffness. Our findings suggest that increased endothelial luminal surface stiffness in microvascular cells may facilitate mechanotransduction and alignment in response to laminar shear stress. Furthermore, the arachidonic acid pathway may mediate this tissue-specific process. An improved understanding of this response will aid in the treatment of organ-specific vascular disease. © 2018 John Wiley & Sons Ltd.

  13. Air Versus Sulfur Hexafluoride Gas Tamponade in Descemet Membrane Endothelial Keratoplasty: A Fellow Eye Comparison.

    Science.gov (United States)

    von Marchtaler, Philipp V; Weller, Julia M; Kruse, Friedrich E; Tourtas, Theofilos

    2018-01-01

    To perform a fellow eye comparison of outcomes and complications when using air or sulfur hexafluoride (SF6) gas as a tamponade in Descemet membrane endothelial keratoplasty (DMEK). One hundred thirty-six eyes of 68 consecutive patients who underwent uneventful DMEK in both eyes for Fuchs endothelial corneal dystrophy were included in this retrospective study. Inclusion criteria were air tamponade (80% of the anterior chamber volume) in the first eye and 20% SF6 gas tamponade (80% of the anterior chamber volume) in the second eye; and same donor tissue culture condition in both eyes. All eyes received laser iridotomy on the day before DMEK. Main outcome measures included preoperative and postoperative best-corrected visual acuity, endothelial cell density, corneal volume, rebubbling rate, and rate of postoperative pupillary block caused by the air/gas bubble. Thirteen of 68 eyes (19.1%) with an air tamponade needed rebubbling compared with 4 of 68 eyes (5.9%) with an SF6 gas tamponade (P = 0.036). Postoperative pupillary block necessitating partial release of air/gas occurred in 1 eye (1.5%) with an air tamponade and 3 eyes (4.4%) with an SF6 gas tamponade (P = 0.301). There were no significant differences in preoperative and postoperative best-corrected visual acuity, endothelial cell density, and corneal volume within 3-month follow-up. Our results confirm the previously reported better graft adhesion when using an SF6 gas tamponade in DMEK without increased endothelial cell toxicity. The rate of pupillary block in eyes with an SF6 gas tamponade was comparable to that with an air tamponade. As a consequence, we recommend using SF6 gas as the tamponade in DMEK.

  14. Efficacy of Tectonic Corneal Patch Graft for Progressive Peripheral Corneal Thinning

    Directory of Open Access Journals (Sweden)

    Cafer Tanrıverdio

    2014-12-01

    Full Text Available Objectives: To report the results of tectonic corneal patch graft (TCPG in patients with progressive peripheral corneal thinning (PCT. Materials and Methods: In this study, we included 8 patients who underwent TCPG for PCT or perforated corneal ulceration at Ankara Training and Research Hospital. Results: We performed TCPG in 7 patients for PCT and in 1 patient for perforated corneal ulceration. Mean age was 57.2±16.7 (38- 82 years. Postoperative follow-up time ranged from 6 to 24 months (mean 13.9±6.7. Possible etiologies leading to progressive PCT were trachoma, infectious corneal ulcer, and rheumatoid arthritis-severe dry eye in 2 patients each. Other 2 patients had a progressive PCT following ocular surgery. One of the patients with infectious corneal ulcer also had a trauma caused by a scissor. Amnion membrane transplantation was performed in 3 patients prior to TCPG. While the anatomic success was achieved in all 8 patients, best-corrected visual acuity (BCVA was 0.1 or better in 4 patients (50%. Postoperative BCVA was better than preoperative BCVA in 6 patients (75%. Local peripheral anterior synechiae developed in two eyes. Conclusion: TCPG is a useful therapeutic option in selected cases of corneal thinning and perforations because it effectively restores the integrity of the globe and allows acceptable visual results. (Turk J Ophthalmol 2014; 44: 440-4

  15. Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants

    Directory of Open Access Journals (Sweden)

    Ozdemir Ozdemir

    2014-08-01

    Full Text Available Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP were allocated to Group 1 (n=138, while those without ROP were allocated to Group 2 (n=236. All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male. The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks, the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g, and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p0.05. Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.

  16. Keratocyte apoptosis and corneal antioxidant enzyme activities after refractive corneal surgery.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Adiguzel, U; Sezer, C; Yis, O; Akyol, G; Hasanreisoglu, B

    2002-01-01

    Refractive corneal surgery induces keratocyte apoptosis and generates reactive oxygen radicals (ROS) in the cornea. The purpose of the present study is to evaluate the correlation between keratocyte apoptosis and corneal antioxidant enzyme activities after different refractive surgical procedures in rabbits. Rabbits were divided into six groups. All groups were compared with the control group (Group 1), after epithelial scraping (Group 2), epithelial scrape and photorefractive keratectomy (PRK) (traditional PRK: Group 3), transepithelial PRK (Group 4), creation of a corneal flap with microkeratome (Group 5) and laser-assisted in situ keratomileusis (LASIK, Group 6). Terminal deoxyribonucleotidyl transferase-mediated dUTP-digoxigenin nick-end labelling assay (to detect DNA fragmentation in situ) and light microscopy were used to detect apoptosis in rabbit eyes. Glutathione peroxidase (Gpx) and superoxide dismutase (SOD) activities of the corneal tissues were measured with spectrophotometric methods. Corneal Gpx and SOD activities decreased significantly in all groups when compared with the control group (P<0.05) and groups 2, 3 and 6 showed a significantly higher amount of keratocyte apoptosis (P<0.05). Not only a negative correlation was observed between corneal SOD activity and keratocyte apoptosis (cc: -0.3648) but Gpx activity also showed negative correlation with keratocyte apoptosis (cc: -0.3587). The present study illustrates the negative correlation between keratocyte apoptosis and corneal antioxidant enzyme activities. This finding suggests that ROS may be partly responsible for keratocyte apoptosis after refractive surgery.

  17. Chitosan and thiolated chitosan: Novel therapeutic approach for preventing corneal haze after chemical injuries.

    Science.gov (United States)

    Zahir-Jouzdani, Forouhe; Mahbod, Mirgholamreza; Soleimani, Masoud; Vakhshiteh, Faezeh; Arefian, Ehsan; Shahosseini, Saeed; Dinarvand, Rasoul; Atyabi, Fatemeh

    2018-01-01

    Corneal haze, commonly caused by deep physical and chemical injuries, can greatly impair vision. Growth factors facilitate fibroblast proliferation and differentiation, which leads to haze intensity. In this study, the potential effect of chitosan (CS) and thiolated-chitosan (TCS) nanoparticles and solutions on inhibition of fibroblast proliferation, fibroblast to myofibroblast differentiation, neovascularization, extracellular matrix (ECM) deposition, and pro-fibrotic cytokine expression was examined. Transforming growth factor beta-1 (TGFβ 1 ) was induced by interleukin-6 (IL6) in human corneal fibroblasts and expression levels of TGFβ 1 , Platelet-derived growth factor (PDGF), α-smooth muscle actins (α-SMA), collagen type I (Col I), fibronectin (Fn) and vascular endothelial growth factor (VEGF) were quantified using qRT-PCR. To assess wound-healing capacity, TCS-treated mice were examined for α-SMA positive cells, collagen deposition, inflammatory cells and neovascularization through pathological immunohistochemistry. The results revealed that CS and TCS could down-regulate the expression levels of TGFβ 1 and PDGF comparable to that of TGFβ 1 knockdown experiment. However, down-regulation of TGFβ 1 was not regulated through miR29b induction. Neovascularization along with α-SMA and ECM deposition were significantly diminished. According to these findings, CS and TCS can be considered as potential anti-fibrotic and anti-angiogenic therapeutics. Furthermore, TCS, thiolated derivative of CS, will increase mucoadhesion of the polymer at the corneal surface which makes the polymer efficient and non-toxic therapeutic approach for corneal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Comparative Ultrastructural Studies on the Impact of Moderate and Hyperthermic Environment on the Corneal Structure of two Species of Wild Rodents

    International Nuclear Information System (INIS)

    Naguib, N.I.; El-Dawi, E.F.

    2011-01-01

    This study was carried out to investigate the impact of environmental climate (temperature) on the corneal structure of two wild rodents; the nocturnal Norway rats (Rattus norvegicus) and the diurnal golden spiny mouse (Acomys russatus). Both rodents were collected from two extreme climatic environment and their dissected corneas were prepared for light, scanning and transmission electron microscopy. The corneas of both rodents are composed of three main layers; an outer epithelium, stroma, Descemet's membrane, and an inner endothelium. The mean thickness of the epithelium, stroma, Descemet's membrane and inner endothelium of both rodents were measured. The scanning electron microscopy revealed that in R. norvegicus and A. russatus; the outermost cells of the corneal epithelium, are mostly polygonal in shape with nearly regular borders and show dense pattern of microplicae with different scatter electron that exhibits three polymorphic appearances (A, B, C) and two (A, B), respectively. Numerous A-light cells with dense microplicae, many B-dark cells with a moderate density of microplicae and few C-dark cells with a less density of microplicae were observed. Using transmission electron microscope, the epithelial cells of both species possess glycocalyx and the cytokeratin filaments are more extensive in the apical epithelial cells in A. russatus. The stroma in R. norvegicus is formed of outer and inner lamellar zones with spaces in between its wavy bundles. In A. russatus, the stroma is formed of one lamellar zone of flattened bundles of highly wavy and branched collagen fibrils. On the other hand, the surface of the endothelial cells in R. norvegicus is slightly bulging with many blebs whereas it showed flattened and nearly smooth surface in A. russatus. In conclusion, the differences in the number of the superficial epithelial cells and the thickness of the stroma and structure of the endothelium of R. norvegicus (nocturnal) and A. russatus (diurnal) are most

  19. Evaluation of corneal higher order aberrations in normal topographic patterns

    Directory of Open Access Journals (Sweden)

    Ali Mirzajani

    2016-06-01

    Conclusions: Based on results in this study, there were a good correlation between corneal topographic pattern and corneal HOAs in normal eyes. These results indicate that the corneal HOAs values are largely determined by the topographic patterns. A larger sample size would perhaps have been beneficial to yield in more accurate outcomes.

  20. Clinical Validation of Point-Source Corneal Topography in Keratoplasty

    NARCIS (Netherlands)

    Vrijling, A C L; Braaf, B.; Snellenburg, J.J.; de Lange, F.; Zaal, M.J.W.; van der Heijde, G.L.; Sicam, V.A.D.P.

    2011-01-01

    Purpose. To validate the clinical performance of point-source corneal topography (PCT) in postpenetrating keratoplasty (PKP) eyes and to compare it with conventional Placido-based topography. Methods. Corneal elevation maps of the anterior corneal surface were obtained from 20 post-PKP corneas using

  1. Corneal surface temperature change as the mode of stimulation of the non-contact corneal aesthesiometer.

    Science.gov (United States)

    Murphy, P J; Morgan, P B; Patel, S; Marshall, J

    1999-05-01

    The non-contact corneal aesthesiometer (NCCA) assesses corneal sensitivity by using a controlled pulse of air, directed at the corneal surface. The purpose of this paper was to investigate whether corneal surface temperature change was a component in the mode of stimulation. Thermocouple experiment: A simple model corneal surface was developed that was composed of a moistened circle of filter paper placed on a thermocouple and mounted on a glass slide. The temperature change produced by different stimulus pressures was measured for five different ambient temperatures. Thermal camera experiment: Using a thermal camera, the corneal surface temperature change was measured in nine young, healthy subjects after exposure to different stimulus air pulses. Pulse duration was set at 0.9 s but was varied in pressure from 0.5 to 3.5 millibars. Thermocouple experiment: An immediate drop in temperature was detected by the thermocouple as soon as the air flow was incident on the filter paper. A greater temperature change was produced by increasing the pressure of the incident air flow. A relationship was found and a calibration curve plotted. Thermal camera experiment: For each subject, a drop in surface temperature was detected at each stimulus pressure. Furthermore, as the stimulus pressure increased, the induced reduction in temperature also increased. A relationship was found and a calibration curve plotted. The NCCA air-pulse stimulus was capable of producing a localized temperature change on the corneal surface. The principal mode of corneal nerve stimulation, by the NCCA air pulse, was the rate of temperature change of the corneal surface.

  2. Applications of biomaterials in corneal wound healing

    Directory of Open Access Journals (Sweden)

    I-Lun Tsai

    2015-04-01

    Full Text Available Disease affecting the cornea is a common cause of blindness worldwide. To date, the amniotic membrane (AM is the most widely used clinical method for cornea regeneration. However, donor-dependent differences in the AM may result in variable clinical outcomes. To overcome this issue, biomaterials are currently under investigation for corneal regeneration in vitro and in vivo. In this article, we highlight the recent advances in hydrogels, bioengineered prosthetic devices, contact lenses, and drug delivery systems for corneal regeneration. In clinical studies, the therapeutic effects of biomaterials, including fibrin and collagen-based hydrogels and silicone contact lenses, have been demonstrated in damaged cornea. The combination of cells and biomaterials may provide potential treatment in corneal wound healing in the future.

  3. Regulation of corneal stroma extracellular matrix assembly.

    Science.gov (United States)

    Chen, Shoujun; Mienaltowski, Michael J; Birk, David E

    2015-04-01

    The transparent cornea is the major refractive element of the eye. A finely controlled assembly of the stromal extracellular matrix is critical to corneal function, as well as in establishing the appropriate mechanical stability required to maintain corneal shape and curvature. In the stroma, homogeneous, small diameter collagen fibrils, regularly packed with a highly ordered hierarchical organization, are essential for function. This review focuses on corneal stroma assembly and the regulation of collagen fibrillogenesis. Corneal collagen fibrillogenesis involves multiple molecules interacting in sequential steps, as well as interactions between keratocytes and stroma matrix components. The stroma has the highest collagen V:I ratio in the body. Collagen V regulates the nucleation of protofibril assembly, thus controlling the number of fibrils and assembly of smaller diameter fibrils in the stroma. The corneal stroma is also enriched in small leucine-rich proteoglycans (SLRPs) that cooperate in a temporal and spatial manner to regulate linear and lateral collagen fibril growth. In addition, the fibril-associated collagens (FACITs) such as collagen XII and collagen XIV have roles in the regulation of fibril packing and inter-lamellar interactions. A communicating keratocyte network contributes to the overall and long-range regulation of stromal extracellular matrix assembly, by creating micro-domains where the sequential steps in stromal matrix assembly are controlled. Keratocytes control the synthesis of extracellular matrix components, which interact with the keratocytes dynamically to coordinate the regulatory steps into a cohesive process. Mutations or deficiencies in stromal regulatory molecules result in altered interactions and deficiencies in both transparency and refraction, leading to corneal stroma pathobiology such as stromal dystrophies, cornea plana and keratoconus. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Dextran Preserves Native Corneal Structure During Decellularization.

    Science.gov (United States)

    Lynch, Amy P; Wilson, Samantha L; Ahearne, Mark

    2016-06-01

    Corneal decellularization has become an increasingly popular technique for generating scaffolds for corneal regeneration. Most decellularization procedures result in tissue swelling, thus limiting their application. Here, the use of a polysaccharide, dextran, to reduce swelling and conserve the native corneal structure during decellularization was investigated. Corneas were treated with 1% Triton X-100, 0.5% sodium dodecyl sulfate, and nucleases under constant rotation followed by extensive washing. To reduce swelling, decellularization solutions were supplemented with 5% dextran either throughout the whole decellularization process or during the washing cycles only. Quantitative analysis of DNA content showed a 96% reduction after decellularization regardless of the addition of dextran. Dextran resulted in a significant reduction in swelling from 3.85 ± 0.43 nm without to 1.94 ± 0.29-2.01 ± 0.37 nm (p dextran must be present throughout the decellularization protocol to preserve the native corneal architecture, anisotropy analysis demonstrated comparable results (0.22 ± 0.03) to the native cornea (0.24 ± 0.02), p > 0.05. Dextran can counteract the detrimental effects of decellularizing agents on the biomechanical properties of the tissue resulting in similar compressive moduli (mean before decellularization: 5.40 ± 1.18 kPa; mean after decellularization with dextran: 5.64 ± 1.34 kPa, p > 0.05). Cells remained viable in the presence of decellularized scaffolds. The findings of this study indicate that dextran not only prevents significant corneal swelling during decellularization but also enhances the maintenance of the native corneal ultrastructure.

  5. Comparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo.

    Science.gov (United States)

    Lee, Jun Ho; Lee, Seunghun; Gho, Yong Song; Song, In Seok; Tchah, Hungwon; Kim, Myoung Joon; Kim, Ki Hean

    2015-03-01

    High-resolution imaging of the cornea is important for studying corneal diseases at cellular levels. Confocal microscopy (CM) has been widely used in the clinic, and two-photon microscopy (TPM) has recently been introduced in various pre-clinical studies. We compared the performance of CM and TPM in normal mouse corneas and neovascularized mouse corneas induced by suturing. Balb/C mice and C57BL/6 mice expressing green fluorescent protein (GFP) were used to compare modalities based on intrinsic contrast and extrinsic fluorescence contrast. CM based on reflection (CMR), CM based on fluorescence (CMF), and TPM based on intrinsic/extrinsic fluorescence and second harmonic generation (SHG) were compared by imaging the same sections of mouse corneas sequentially in vivo. In normal mouse corneas, CMR visualized corneal cell morphologies with some background noise, and CMF visualized GFP expressing corneal cells clearly. TPM visualized corneal cells and collagen in the stroma based on fluorescence and SHG, respectively. However, in neovascularized mouse corneas, CMR could not resolve cells deep inside the cornea due to high background noise from the effects of increased structural irregularity induced by suturing. CMF and TPM visualized cells and induced vasculature better than CMR because both collect signals from fluorescent cells only. Both CMF and TPM had signal decays with depth due to the structural irregularity, with CMF having faster signal decay than TPM. CMR, CMF, and TPM showed different degrees of image degradation in neovascularized mouse corneas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Electrospun nanofibrous SF/P(LLA-CL) membrane: a potential substratum for endothelial keratoplasty.

    Science.gov (United States)

    Chen, Junzhao; Yan, Chenxi; Zhu, Mengyu; Yao, Qinke; Shao, Chunyi; Lu, Wenjuan; Wang, Jing; Mo, Xiumei; Gu, Ping; Fu, Yao; Fan, Xianqun

    2015-01-01

    Cornea transplant technology has progressed markedly in recent decades, allowing surgeons to replace diseased corneal endothelium by a thin lamellar structure. A thin, transparent, biocompatible, tissue-engineered substratum with corneal endothelial cells for endothelial keratoplasty is currently of interest. Electrospinning a nanofibrous structure can simulate the extracellular matrix and have beneficial effects for cell culture. Silk fibroin (SF) has good biocompatibility but poor mechanical properties, while poly(L-lactic acid-co-ε-caprolactone) (P(LLA-CL)) has good mechanical properties but poor biocompatibility. Blending SF with P(LLA-CL) can maintain the advantages of both these materials and overcome their disadvantages. Blended electrospun nanofibrous membranes may be suitable for regeneration of the corneal endothelium. The aim of this study was to produce a tissue-engineered construct suitable for endothelial keratoplasty. Five scaffolds containing different SF:P(LLA-CL) blended ratios (100:0, 75:25, 50:50, 25:75, 0:100) were manufactured. A human corneal endothelial (B4G12) cell line was cultured on the membranes. Light transmission, speed of cell adherence, cell viability (live-dead test), cell proliferation (Ki-67, BrdU staining), and cell monolayer formation were detected on membranes with the different blended ratios, and expression of some functional genes was also detected by real-time polymerase chain reaction. Different blended ratios of scaffolds had different light transmittance properties. The 25:75 blended ratio membrane had the best transmittance among these scaffolds. All electrospun nanofibrous membranes showed improved speed of cell adherence when compared with the control group, especially when the P(LLA-CL) ratio increased. The 25:75 blended ratio membranes also had the highest cell proliferation. B4G12 cells could form a monolayer on all scaffolds, and most functional genes were also stably expressed on all scaffolds. Only two genes

  7. Gliovascular and cytokine interactions modulate brain endothelial barrier in vitro.

    Science.gov (United States)

    Chaitanya, Ganta V; Cromer, Walter E; Wells, Shannon R; Jennings, Merilyn H; Couraud, P Olivier; Romero, Ignacio A; Weksler, Babette; Erdreich-Epstein, Anat; Mathis, J Michael; Minagar, Alireza; Alexander, J Steven

    2011-11-23

    The glio-vascular unit (G-unit) plays a prominent role in maintaining homeostasis of the blood-brain barrier (BBB) and disturbances in cells forming this unit may seriously dysregulate BBB. The direct and indirect effects of cytokines on cellular components of the BBB are not yet unclear. The present study compares the effects of cytokines and cytokine-treated astrocytes on brain endothelial barrier. 3-dimensional transwell co-cultures of brain endothelium and related-barrier forming cells with astrocytes were used to investigate gliovascular barrier responses to cytokines during pathological stresses. Gliovascular barrier was measured using trans-endothelial electrical resistance (TEER), a sensitive index of in vitro barrier integrity. We found that neither TNF-α, IL-1β or IFN-γ directly reduced barrier in human or mouse brain endothelial cells or ECV-304 barrier (independent of cell viability/metabolism), but found that astrocyte exposure to cytokines in co-culture significantly reduced endothelial (and ECV-304) barrier. These results indicate that the barrier established by human and mouse brain endothelial cells (and other cells) may respond positively to cytokines alone, but that during pathological conditions, cytokines dysregulate the barrier forming cells indirectly through astrocyte activation involving reorganization of junctions, matrix, focal adhesion or release of barrier modulating factors (e.g. oxidants, MMPs). © 2011 Chaitanya et al; licensee BioMed Central Ltd.

  8. Assessment of the Dutch organ-culture system of corneal preservation within the Eye Bank of South Australia.

    Science.gov (United States)

    Williams, K A; Noack, L M; Alfrich, S J; Danz, R; Erickson, S A; Coster, D J

    1988-02-01

    Thirteen per cent of all corneas harvested by the Eye Bank of South Australia during 1986 were discarded because storage time in McCarey-Kaufman medium exceeded four days. We have therefore examined the suitability of the Dutch method of long-term corneal storage for our purposes. Twenty-two human corneas that had been discarded from the Eye Bank were assessed using the trypan blue-sucrose staining technique, and then placed into long-term storage for 15 to 17 days. They were then reassessed by vital dye staining before permanent flat-mounts were prepared for silver staining of the endothelium. A good correlation (albeit subjective) was found between the non-destructive and destructive techniques of endothelial cell assessment. Those corneas that failed to survive organ culture storage were easily detected. The Dutch system of corneal preservation and post-storage assessment seems well-suited to Australian eye-banking.

  9. Host immune cellular reactions in corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Nizar S. Abdelfattah

    2016-04-01

    Full Text Available Corneal neovascularization (CNV is a global important cause of visual impairment. The immune mechanisms leading to corneal heme- and lymphangiogenesis have been extensively studied over the past years as more attempts were made to develop better prophylactic and therapeutic measures. This article aims to discuss immune cells of particular relevance to CNV, with a focus on macrophages, Th17 cells, dendritic cells and the underlying immunology of common pathologies involving neovascularization of the cornea. Hopefully, a thorough understanding of these topics would propel the efforts to halt the detrimental effects of CNV.

  10. Research on inhibition of corneal neovascularization

    Directory of Open Access Journals (Sweden)

    Zhang-Hui Yang

    2015-12-01

    Full Text Available Corneal transparency is the basis of the normal physiological functions.However, corneal neovascularization(CNVmay occur in the infection, mechanical and chemical injury or under other pathological conditions,which make the cornea lose original transparency and severe visual impairment. In recent years, along with the development of immunology, molecular biology, biochemistry and other disciplines, there is more in-depth understanding on the CNV, and clinical treatment of CNV has made new breakthroughs. This article provides an overview of the inhibition of CNV.

  11. The effect of ABO blood incompatibility on corneal transplant failure in conditions with low-risk of graft rejection.

    Science.gov (United States)

    Dunn, Steven P; Stark, Walter J; Stulting, R Doyle; Lass, Jonathan H; Sugar, Alan; Pavilack, Mark A; Smith, Patricia W; Tanner, Jean Paul; Dontchev, Mariya; Gal, Robin L; Beck, Roy W; Kollman, Craig; Mannis, Mark J; Holland, Edward J

    2009-03-01

    To determine whether corneal graft survival over a 5-year follow-up period was affected by ABO blood type compatibility in participants in the Cornea Donor Study undergoing corneal transplantation principally for Fuchs dystrophy or pseudophakic corneal edema, conditions at low-risk for graft rejection. Multi-center prospective, double-masked, clinical trial. ABO blood group compatibility was determined for 1,002 donors and recipients. During a 5-year follow-up period, episodes of graft rejection were documented, and graft failures were classified as to whether or not they were attributable to immunologic rejection. Endothelial cell density was determined by a central reading center for a subset of subjects. ABO donor-recipient incompatibility was not associated with graft failure attributable to any cause including graft failure because of rejection, or with the occurrence of a rejection episode. The 5-year cumulative incidence of graft failure attributable to rejection was 32 (6%) for recipients with ABO recipient-donor compatibility and 12 (4%) for those with ABO incompatibility (hazard ratio, 0.65; 95% confidence interval, 0.33 to 1.25; P = .20). The 5-year incidence for a definite rejection episode, irrespective of whether graft failure ultimately occurred, was 64 (12%) for ABO compatible compared with 25 (8%) for ABO incompatible cases (P = .09). Among clear grafts at 5 years, percent loss of endothelial cells was similar in ABO compatible and incompatible cases. In patients undergoing penetrating keratoplasty for Fuchs dystrophy or pseudophakic corneal edema, ABO matching is not indicated since ABO incompatibility does not increase the risk of transplant failure attributable to graft rejection.

  12. Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Morgan-Warren PJ

    2015-02-01

    Full Text Available Peter J Morgan-Warren, Walter Andreatta, Amit K Patel Department of Ophthalmology, Solihull Hospital, Heart of England NHS Foundation Trust, Birmingham, UK Purpose: Opacification of hydrophilic acrylic intraocular lenses (IOLs is an emerging complication following Descemet stripping automated endothelial keratoplasty (DSAEK. We report six cases and review the current literature.Methods: In this retrospective, noncomparative, observational case series, patients with IOL opacification after previous DSAEK surgery were identified from corneal clinic records. Case notes were reviewed for demographic details, indication for DSAEK, IOL model, incidence of rebubbling, and postoperative course.Results: Six patients developed IOL opacification after DSAEK. All patients had Fuchs’ endothelial dystrophy and had previously received hydrophilic acrylic IOL models. Central anterior IOL opacification was noted in all six cases. Five cases (83% had required rebubbling due to dislocated graft tissue, and one had an early postoperative intraocular pressure (IOP rise. Five cases (83% were managed conservatively, and one case with a failed graft underwent redo DSAEK and IOL exchange.Conclusion: Repeated exposure to intracameral air, raised IOP, and other patient influences may be major etiological factors for IOL opacification after DSAEK. We advise avoiding hydrophilic acrylic IOL models in patients who may require future endothelial keratoplasty. Keywords: IOL, DSAEK, lamellar keratoplasty, endothelial corneal transplantation

  13. Current status of accelerated corneal cross-linking

    Directory of Open Access Journals (Sweden)

    Michael Mrochen

    2013-01-01

    Full Text Available Corneal cross-linking with riboflavin is a technique to stabilize or reduce corneal ectasia, in diseases such as keratoconus and post-laser-assisted in situ keratomileusis (LASIK ectasia. There is an interest by patient as well as clinicians to reduce the overall treatment time. Especially, the introduction of corneal cross-linking in combination with corneal laser surgery demands a shorter treatment time to assure a sufficient patient flow. The principles and techniques of accelerated corneal cross-linking is discussed.

  14. Hypoxia-induced mitogenic factor enhances angiogenesis by promoting proliferation and migration of endothelial cells

    International Nuclear Information System (INIS)

    Tong Qiangsong; Zheng Liduan; Li Bo; Wang Danming; Huang Chuanshu; Matuschak, George M.; Li Dechun

    2006-01-01

    Our previous studies have indicated that hypoxia-induced mitogenic factor (HIMF) has angiogenic properties in an in vivo matrigel plug model and HIMF upregulates expression of vascular endothelial growth factor (VEGF) in mouse lungs and cultured lung epithelial cells. However, whether HIMF exerts angiogenic effects through modulating endothelial cell function remains unknown. In this study, mouse aortic rings cultured with recombinant HIMF protein resulted in enhanced vascular sprouting and increased endothelial cell spreading as confirmed by Dil-Ac-LDL uptake, von Willebrand factor and CD31 staining. In cultured mouse endothelial cell line SVEC 4-10, HIMF dose-dependently enhanced cell proliferation, in vitro migration and tubulogenesis, which was not attenuated by SU1498, a VEGFR2/Flk-1 receptor tyrosine kinase inhibitor. Moreover, HIMF stimulation resulted in phosphorylation of Akt, p38 and ERK1/2 kinases in SVEC 4-10 cells. Treatment of mouse aortic rings and SVEC 4-10 cells with LY294002, but not SB203580, PD098059 or U0126, abolished HIMF-induced vascular sprouting and angiogenic responses. In addition, transfection of a dominant-negative mutant of phosphatidylinositol 3-kinase (PI-3K), Δp85, blocked HIMF-induced phosphorylation of Akt, endothelial activation and tubulogenesis. These results indicate that HIMF enhances angiogenesis by promoting proliferation and migration of endothelial cells via activation of the PI-3K/Akt pathways

  15. Corneal hydrops induced by Bell’s paralysis in a case of corneal ectasia

    Directory of Open Access Journals (Sweden)

    Lokman Aslan

    2017-09-01

    Full Text Available An 18-year-old male patient presented with suddenly decreased vision, itching, corneal edema and an inability to close the left eye. They had left Bell’s paralysis for two weeks and had used high diopter glasses for five years. The best corrected visual acuity was 0.4 in their right eye and counting fingers in the left eye. Biomicroscopic examination revealed thinning and steepening of the cornea in the right eye and anterior protrusion of the cornea, stromal edema and punctate disruption of the epithelium in the left eye. Topographic image of the right eye was consistent with keratoconus. Six months later, stromal edema gradually regressed and a corneal scar ensued. This case presentation emphasizes that Bell’s palsy may induce disease progression in a patient with preexisting corneal ectasia and results in corneal hydrops. [Arch Clin Exp Surg 2017; 6(3.000: 165-167

  16. Corneal-Wavefront guided transepithelial photorefractive keratectomy after corneal collagen cross linking in keratoconus

    Directory of Open Access Journals (Sweden)

    Massimo Camellin

    2017-01-01

    Conclusions: Corneal-Wavefront guided transepithelial PRK ablation profiles after conventional CXL yields to good visual, optical, and refractive results. These treatments are safe and efficacious for the correction of refracto-therapeutic problems in keratoconic patients.

  17. Estudio del endotelio corneal en el queratocono por microscopia confocal Study of the corneal endothelium confocal microscopy in keratoconus

    Directory of Open Access Journals (Sweden)

    María del Carmen Benítez Merino

    2011-12-01

    CONFOSCAN S-4 in order to study their corneal endothelium according to the keratoconus condition. The evolution of keratoconus was analyzed in terms of age and sex. Tailor-made software made the analysis and processing of images possible. Results: The ages of patients with keratoconus grades I and II, (35,2 and 34,7 years were pretty similar whereas the average age of keratoconus grade III patients (38,4 years was higher, but no significant differences were found (p=0,279. Females prevailed (in our study accounting for 80,4%. One hundred percent of keratoconus grade III presented with pathological endothelium. The values averages of the cell density in the keratoconus grade III (2585,9 cell/mm2 it was not significant (p= 0,339. The polymegathism of 48, 69% in the keratoconus grade III were significant (p= 0,002. As for the pleomorphism, the differences were statistically significant among the three grades (p= 0,002 Conclusions: Keratoconus grade II prevailed in women and the grade I in men. From the morphological point of view, the morphological findings lied in the form and size of the endothelial cells. Keratoconus grade II and II showed a combination of medium and large cells and loss of hexagonal shape. The cell density was within the normal range of values for any keratoconus grade.

  18. Evolution of endothelial keratoplasty.

    Science.gov (United States)

    Price, Francis W; Price, Marianne O

    2013-11-01

    Endothelial keratoplasty has evolved into a popular alternative to penetrating keratoplasty (PK) for the treatment of endothelial dysfunction. Although the earliest iterations were challenging and were not widely adopted, the iteration known as Descemet stripping endothelial keratoplasty (DSEK) has gained widespread acceptance. DSEK combines a simplified technique for stripping dysfunctional endothelium from the host cornea and microkeratome dissection of the donor tissue, a step now commonly completed in advance by eye bank technicians. Studies show that a newer endothelial keratoplasty iteration, known as Descemet membrane endothelial keratoplasty (DMEK), provides an even faster and better visual recovery than DSEK does. In addition, DMEK significantly reduces the risk of immunologic graft rejection episodes compared with that in DSEK or in PK. Although the DMEK donor tissue, consisting of the bare endothelium and Descemet membrane without any stroma, is more challenging to prepare and position in the recipient eye, recent improvements in instrumentation and surgical techniques are increasing the ease and the reliability of the procedure. DSEK successfully mitigates 2 of the main liabilities of PK: ocular surface complications and structural problems (including induced astigmatism and perpetually weak wounds), whereas DMEK further mitigates the 2 principal remaining liabilities of PK: immunologic graft reactions and secondary glaucoma from prolonged topical corticosteroid use.

  19. Mitochondria and Endothelial Function

    Science.gov (United States)

    Kluge, Matthew A.; Fetterman, Jessica L.; Vita, Joseph A.

    2013-01-01

    In contrast to their role in other cell types with higher energy demands, mitochondria in endothelial cells primarily function in signaling cellular responses to environmental cues. This article provides an overview of key aspects of mitochondrial biology in endothelial cells, including subcellular location, biogenesis, dynamics, autophagy, ROS production and signaling, calcium homeostasis, regulated cell death, and heme biosynthesis. In each section, we introduce key concepts and then review studies showing the importance of that mechanism to endothelial control of vasomotor tone, angiogenesis, and inflammatory activation. We particularly highlight the small number of clinical and translational studies that have investigated each mechanism in human subjects. Finally, we review interventions that target different aspects of mitochondrial function and their effects on endothelial function. The ultimate goal of such research is the identification of new approaches for therapy. The reviewed studies make it clear that mitochondria are important in endothelial physiology and pathophysiology. A great deal of work will be needed, however, before mitochondria-directed therapies are available for the prevention and treatment of cardiovascular disease. PMID:23580773

  20. Síndrome iridocórneo-endotelial: Presentación de un caso Iridocorneal-endothelial syndrome: A case presentation

    Directory of Open Access Journals (Sweden)

    Belmary Aragonés Cruz

    2007-12-01

    Full Text Available Se describen los cambios endoteliales en varios pacientes de una serie de casos que presentaron atrofia esencial progresiva de iris unilateral en diversos estadios. Se comparan con los hallazgos encontrados en las escasas publicaciones existentes sobre las alteraciones endoteliales que presentan los pacientes con síndromes iridocórneo-endoteliales. explorados con microscopio confocal. A todos se les realizó raspado corneal para mediante reacción de polimerasa en cadena descartar etiología herpética.The endothelial changes occurred in several patients from a case series that presented with unilateral progressive essential iris atrophy at various stagings were described and compared with those findings of the few publications on the endothelial alterations in patients with iridocorneal endothelial syndromes observed at a confocal microscope. All the patients were performed corneal exudate to rule out any herpetic etiology through polymerase chain reaction testing.

  1. Ultraviolet induced lysosome activity in corneal epithelium

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, A.P.

    1980-01-01

    A 5.000 W Xe-Hg high pressure lamp and a double monochromator were used to produce a 3.3 nm half-bandpass ultraviolet radiation at 295 nm. Pigmented rabbit eyes were irradiated with radiant exposures from 140 Jm/sup -2/ to 10.000 Jm/sup -2/ and evaluated by slit-lamp biomicroscopy, light and electron microscopy. Corneal threshold (Hsub(c) was 200 Jm/sup -2/ and lens threshold (Hsub(L)) was 7.500 Jm/sup -2/. The most repeatable and reliable corneal response to these levels of UV was the development of corneal epithelial granules. Histological changes included a loss of superficial epithelial cells and selective UV induced autolysis of the wing cells. It is suggested that the biomicroscopically observed granules are the clinical manifestation of the secondary lysosomes revealed by light and electron microscopy. It is proposed that UV breaks down the primary lysosome membranes to release hydrolytic enzymes which in turn form the secondary lysosomes during autolysis. Extreme levels of radiant exposure at 295 nm result in indiscriminate destruction of all layers of the corneal epithelium, but the posterior cornea was spared.

  2. Ultraviolet induced lysosome activity in corneal epithelium

    International Nuclear Information System (INIS)

    Cullen, A.P.

    1980-01-01

    A 5.000 W Xe-Hg high pressure lamp and a double monochromator were used to produce a 3.3 nm half-bandpass ultraviolet radiation at 295 nm. Pigmented rabbit eyes were irradiated with radiant exposures from 140 Jm -2 to 10.000 Jm -2 and evaluated by slit-lamp biomicroscopy, light and electron microscopy. Corneal threshold (Hsub(c) was 200 Jm -2 and lens threshold (Hsub(L)) was 7.500 Jm -2 . The most repeatable and reliable corneal response to these levels of UV was the development of corneal epithelial granules. Histological changes included a loss of superficial epithelial cells and selective UV induced autolysis of the wing cells. It is suggested that the biomicroscopically observed granules are the clinical manifestation of the secondary lysosomes revealed by light and electron microscopy. It is proposed that UV breaks down the primary lysosome membranes to release hydrolytic enzymes which in turn form the secondary lysosomes during autolysis. Extreme levels of radiant exposure at 295 nm result in indiscriminate destruction of all layers of the corneal epithelium, but the posterior cornea was spared. (orig.) [de

  3. Corneal ulcers: For the general practitioner

    African Journals Online (AJOL)

    Speci c enquiry as to instillation of medication (e.g. steroid drops) or home ... unaided and then with pinhole, with the fellow eye occluded. As a corneal ... topical anaesthetic drops will assist in making the patient comfortable enough to open ...

  4. Past and present of corneal refractive surgery

    DEFF Research Database (Denmark)

    Vestergaard, Anders Højslet

    Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become...

  5. Management of Corneal Bee Sting Injuries.

    Science.gov (United States)

    Rai, Ruju R; Gonzalez-Gonzalez, Luis A; Papakostas, Thanos D; Siracuse-Lee, Donna; Dunphy, Robert; Fanciullo, Lisa; Cakiner-Egilmez, Tulay; Daly, Mary K

    2017-01-01

    To review the management of keratitis after corneal bee stings and to report a case of deep stromal corneal infiltrate secondary to a retained bee stinger managed conservatively in a patient who presented three days after unsanitary manipulation of the stinger apparatus. Case report and review of literature. A 57-year-old male beekeeper was evaluated for pain, blurry vision, and photosensitivity after a corneal bee sting. Of note, the venom sac had been removed with dirty tweezers three days prior to his visit. On exam, a focal infiltrate with diffuse edema was seen surrounding a retained bee stinger in the peripheral cornea. Trace cells in the anterior chamber were also noted. Based on a high suspicion for infectious keratitis, a conservative treatment strategy was elected. Administration of broad-spectrum topical antibiotics with concomitant abstention of corticosteroids led to rapid resolution of the symptoms. Over 16 months of follow-up, the stinger has remained in situ without migration and the patient has maintained 20/20 visual acuity without complications. There is debate on the preferred method for the management of corneal injury secondary to bee stings, especially when it is associated with a retained stinger. We herein present our findings in our appraisal of reported cases. In the aftermath of an ocular bee sting, close surveillance for inflammation and infection is essential. Individual manifestations of these injuries vary in timing, type, and severity; therefore, the accessibility of the stinger and the evolving clinical picture should guide therapeutic decisions.

  6. 21 CFR 886.1220 - Corneal electrode.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal electrode. 886.1220 Section 886.1220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... to the cornea to provide data showing the changes in electrical potential in the retina after...

  7. Corneal topography measurements for biometric applications

    Science.gov (United States)

    Lewis, Nathan D.

    The term biometrics is used to describe the process of analyzing biological and behavioral traits that are unique to an individual in order to confirm or determine his or her identity. Many biometric modalities are currently being researched and implemented including, fingerprints, hand and facial geometry, iris recognition, vein structure recognition, gait, voice recognition, etc... This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have his or her corneal topography measured. Human subject topography data were collected with this device and compared to measurements made with the commercially available Keratron Piccolo topographer (Optikon, Rome, Italy). A third topographer that departs from the standard Placido disk technology allows for arbitrary pattern illumination through the use of LCD monitors. This topographer was built and tested to be used in future research studies. Topography data was collected from 59 subjects and modeled using Zernike polynomials, which provide for a simple method of compressing topography data and comparing one topographical measurement with a database for biometric identification. The data were analyzed to determine the biometric error rates associated with corneal topography measurements. Reasonably accurate results, between three to eight percent simultaneous false match and false non-match rates, were achieved.

  8. Role of glutathione biosynthesis in endothelial dysfunction and fibrosis.

    Science.gov (United States)

    Espinosa-Díez, Cristina; Miguel, Verónica; Vallejo, Susana; Sánchez, Francisco J; Sandoval, Elena; Blanco, Eva; Cannata, Pablo; Peiró, Concepción; Sánchez-Ferrer, Carlos F; Lamas, Santiago

    2018-04-01

    Glutathione (GSH) biosynthesis is essential for cellular redox homeostasis and antioxidant defense. The rate-limiting step requires glutamate-cysteine ligase (GCL), which is composed of the catalytic (GCLc) and the modulatory (GCLm) subunits. To evaluate the contribution of GCLc to endothelial function we generated an endothelial-specific Gclc haplo-insufficient mouse model (Gclc e/+ mice). In murine lung endothelial cells (MLEC) derived from these mice we observed a 50% reduction in GCLc levels compared to lung fibroblasts from the same mice. MLEC obtained from haplo-insufficient mice showed significant reduction in GSH levels as well as increased basal and stimulated ROS levels, reduced phosphorylation of eNOS (Ser 1177) and increased eNOS S-glutathionylation, compared to MLEC from wild type (WT) mice. Studies in mesenteric arteries demonstrated impaired endothelium-dependent vasodilation in Gclc(e/+) male mice, which was corrected by pre-incubation with GSH-ethyl-ester and BH 4 . To study the contribution of endothelial GSH synthesis to renal fibrosis we employed the unilateral ureteral obstruction model in WT and Gclc(e/+) mice. We observed that obstructed kidneys from Gclc(e/+) mice exhibited increased deposition of fibrotic markers and reduced Nrf2 levels. We conclude that the preservation of endothelial GSH biosynthesis is not only critical for endothelial function but also in anti-fibrotic responses. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. A new nanosecond UV laser at 355 nm: early results of corneal flap cutting in a rabbit model.

    Science.gov (United States)

    Trost, Andrea; Schrödl, Falk; Strohmaier, Clemens; Bogner, Barbara; Runge, Christian; Kaser-Eichberger, Alexandra; Krefft, Karolina; Vogel, Alfred; Linz, Norbert; Freidank, Sebastian; Hilpert, Andrea; Zimmermann, Inge; Grabner, Günther; Reitsamer, Herbert A

    2013-12-03

    A new 355 nm UV laser was used for corneal flap cutting in an animal model and tested for clinical and morphologic alterations. Corneal flaps were created (Chinchilla Bastards; n = 25) with an UV nanosecond laser at 355 nm (150 kHz, pulse duration 850 ps, spot-size 1 μm, spot spacing 6 × 6 μm, side cut Δz 1 μm; cutting depth 130 μm) and pulse energies of 2.2 or 2.5 μJ, respectively. Following slit-lamp examination, animals were killed at 6, 12, and 24 hours after treatment. Corneas were prepared for histology (hematoxylin and eosin [HE], TUNEL-assay) and evaluated statistically, followed by ultrastructural investigations. Laser treatment was tolerated well, flap lift was easier at 2.5 μJ compared with 2.2 μJ. Standard HE at 24 hours revealed intact epithelium in the horizontal cut, with similar increase in corneal thickness at both energies. Irrespective of energy levels, TUNEL assay revealed comparable numbers of apoptotic cells in the horizontal and vertical cut at 6, 12, and 24 hours, becoming detectable in the horizontal cut as an acellular stromal band at 24 hours. Ultrastructural analysis revealed regular morphology in the epi- and endothelium, while in the stroma, disorganized collagen lamellae were detectable representing the horizontal cut, again irrespective of energy levels applied. This new UV laser revealed no epi- nor endothelial damage at energies feasible for corneal flap cutting. Observed corneal swelling was lower compared with existing UV laser studies, albeit total energy applied here was much higher. Observed loss of stromal keratinocytes is comparable with available laser systems. Therefore, this new laser is suitable for refractive surgery, awaiting its test in a chronic environment.

  10. Effects of artificial tear treatment on corneal epithelial thickness and corneal topography findings in dry eye patients.

    Science.gov (United States)

    Çakır, B; Doğan, E; Çelik, E; Babashli, T; Uçak, T; Alagöz, G

    2018-05-01

    To investigate the effects of artificial tear treatment on central corneal epithelial thickness, and central, mid-peripheral and peripheral corneal thicknesses in patients with dry eye disease (DED). Patients with DED underwent ocular examinations, including Schirmer-2 test, slit lamp examination for tear break-up time (BUT), corneal topography (CT) for measuring mean central, mid-peripheral and peripheral corneal thickness values and anterior segment optic coherence tomography (AS-OCT) for obtaining central corneal epithelial thickness. After artificial tear treatment (carboxymethylcellulose and sodium hyaluronate formulations) for one month, patients were examined again at a second visit and the results were compared. Sixty-one eyes of 33 female dry eye patients (mean age: 38.3±5.7 years) were enrolled. The mean follow-up time was 36.4±3.3 days. The mean tear BUT and Schirmer-1 tests revealed significant improvement after treatment (P=0.000, P=0.000, respectively). Central corneal epithelium and mean mid-peripheral corneal thicknesses measured significantly higher after treatment (P=0.001, P=0.02). Changes in central and peripheral corneal thicknesses were not statistically significant. Artificial tear treatment in dry eye patients seems to increase central corneal epithelial and mid-peripheral corneal thicknesses. Measurement of corneal epithelial thickness can be a useful tool for evaluation of treatment response in dry eye patients. Further long-term prospective studies are needed to investigate this item. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. The Steroids for Corneal Ulcers Trial

    Science.gov (United States)

    Srinivasan, Muthiah; Mascarenhas, Jeena; Rajaraman, Revathi; Ravindran, Meenakshi; Lalitha, Prajna; Glidden, David V.; Ray, Kathryn J.; Hong, Kevin C.; Oldenburg, Catherine E.; Lee, Salena M.; Zegans, Michael E.; McLeod, Stephen D.; Lietman, Thomas M.; Acharya, Nisha R.

    2013-01-01

    Objectives To provide comprehensive trial methods and baseline data for the Steroids for Corneal Ulcers Trial and to present epidemiological characteristics such as risk factors, causative organisms, and ulcer severity. Methods Baseline data from a 1:1 randomized, placebo-controlled, double-masked clinical trial comparing prednisolone phosphate, 1%, with placebo as adjunctive therapy for the treatment of bacterial corneal ulcers. Eligible patients had a culture-positive bacterial corneal ulcer and had been taking moxifloxacin for 48 hours. The primary outcome for the trial is best spectacle-corrected visual acuity at 3 months from enrollment. This report provides comprehensive baseline data, including best spectacle-corrected visual acuity, infiltrate size, microbio-logical results, and patient demographics, for patients enrolled in the trial. Results Of 500 patients enrolled, 97% were in India. Two hundred twenty patients (44%) were agricultural workers. Median baseline visual acuity was 0.84 logMAR (Snellen, 20/125) (interquartile range, 0.36-1.7; Snellen, 20/50 to counting fingers). Baseline visual acuity was not significantly different between the United States and India. Ulcers in India had larger infiltrate/scar sizes (P=.04) and deeper infiltrates (P=.04) and were more likely to be localized centrally (P=.002) than ulcers enrolled in the United States. Gram-positive bacteria were the most common organisms isolated from the ulcers (n=366, 72%). Conclusions The Steroids for Corneal Ulcers Trial will compare the use of a topical corticosteroid with placebo as adjunctive therapy for bacterial corneal ulcers. Patients enrolled in this trial had diverse ulcer severity and on average significantly reduced visual acuity at presentation. PMID:21987581

  12. Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery

    DEFF Research Database (Denmark)

    Krarup, Therese; Holm, Lars Morten; la Cour, Morten

    2014-01-01

    and the contralateral eye operated by CPS (stop and chop technique). Both eyes had intraocular aspheric lenses implanted. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), central corneal endothelial cell count and hexagonality with a non-contact specular microscope were assessed......PURPOSE: To investigate the amount of endothelial cell loss (ECL) and refractive predictability by femtosecond laser-assisted cataract surgery (FLACS) compared to conventional phacoemulsification cataract surgery (CPS). METHODS: Forty-seven patients had one eye operated by FLACS...

  13. Systematic assessment of microneedle injection into the mouse cornea.

    Science.gov (United States)

    Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S

    2012-06-20

    Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

  14. Systematic assessment of microneedle injection into the mouse cornea

    Directory of Open Access Journals (Sweden)

    Matthaei Mario

    2012-06-01

    Full Text Available Abstract Background Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Methods Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. Results A mean corneal area of 5.0 ±1.4 mm2 (mean ± SD and 7.7 ±1.4 mm2 was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Conclusions Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively

  15. Anatomical characterization of central, apical and minimal corneal thickness

    Directory of Open Access Journals (Sweden)

    Federico Saenz-Frances

    2014-08-01

    Full Text Available AIM: To anatomically locate the points of minimum corneal thickness and central corneal thickness (pupil center in relation to the corneal apex.METHODS: Observational, cross-sectional study, 299 healthy volunteers. Thickness at the corneal apex (AT, minimum corneal thickness (MT and corneal thickness at the pupil center (PT were determined using the pentacam. Distances from the corneal apex to MT (MD and PT (PD were calculated and their quadrant position (taking the corneal apex as the reference determined:point of minimum thickness (MC and point of central thickness (PC depending on the quadrant position. Two multivariate linear regression models were constructed to examine the influence of age, gender, power of the flattest and steepest corneal axes, position of the flattest axis, corneal volume (determined using the Pentacam and PT on MD and PD. The effects of these variables on MC and PC were also determined in two multinomial regression models.RESULTS: MT was located at a mean distance of 0.909 mm from the apex (79.4% in the inferior-temporal quadrant. PT was located at a mean distance of 0.156 mm from the apex. The linear regression model for MD indicated it was significantly influenced by corneal volume (B=-0.024; 95%CI:-0.043 to -0.004. No significant relations were identified in the linear regression model for PD or the multinomial logistic regressions for MC and PC.CONCLUSION: MT was typically located at the inferior-temporal quadrant of the cornea and its distance to the corneal apex tended to decrease with the increment of corneal volume.

  16. Wine and endothelial function.

    Science.gov (United States)

    Caimi, G; Carollo, C; Lo Presti, R

    2003-01-01

    In recent years many studies have focused on the well-known relationship between wine consumption and cardiovascular risk. Wine exerts its protective effects through various changes in lipoprotein profile, coagulation and fibrinolytic cascades, platelet aggregation, oxidative mechanisms and endothelial function. The last has earned more attention for its implications in atherogenesis. Endothelium regulates vascular tone by a delicate balancing among vasorelaxing (nitric oxide [NO]) and vasoconstrincting (endothelins) factors produced by endothelium in response to various stimuli. In rat models, wine and other grape derivatives exerted an endothelium-dependent vasorelaxing capacity especially associated with the NO-stimulating activity of their polyphenol components. In experimental conditions, reservatrol (a stilbene polyphenol) protected hearts and kidneys from ischemia-reperfusion injury through antioxidant activity and upregulation of NO production. Wine polyphenols are also able to induce the expression of genes involved in the NO pathway within the arterial wall. The effects of wine on endothelial function in humans are not yet clearly understood. A favorable action of red wine or dealcoholized wine extract or purple grape juice on endothelial function has been observed by several authors, but discrimination between ethanol and polyphenol effects is controversial. It is, however likely that regular and prolonged moderate wine drinking positively affects endothelial function. The beneficial effects of wine on cardiovascular health are greater if wine is associated with a healthy diet. The most recent nutritional and epidemiologic studies show that the ideal diet closely resembles the Mediterranean diet.

  17. Infections and endothelial cells

    NARCIS (Netherlands)

    Keller, Tymen T.; Mairuhu, Albert T. A.; de Kruif, Martijn D.; Klein, Saskia K.; Gerdes, Victor E. A.; ten Cate, Hugo; Brandjes, Dees P. M.; Levi, Marcel; van Gorp, Eric C. M.

    2003-01-01

    Systemic infection by various pathogens interacts with the endothelium and may result in altered coagulation, vasculitis and atherosclerosis. Endothelium plays a role in the initiation and regulation of both coagulation and fibrinolysis. Exposure of endothelial cells may lead to rapid activation of

  18. Unilateral corneal leukoplakia without limbal involvement

    Directory of Open Access Journals (Sweden)

    Hirano K

    2015-05-01

    Full Text Available Koji Hirano,1 Mihoko Koide,2 Yoshikazu Mizoguchi,3 Yasuhiro Osakabe,4 Kaoru-Araki Sasaki5 1Department of Ophthalmology, Ban Buntane Hotokukai Hospital, School of Medicine, Fujita Health University, Nagoya, Japan; 2Koide Internal Medicine and Eye Clinic, Nagoya, Japan; 3Department of Pathology, Ban Buntane Hotokukai Hospital, School of Medicine, Fujita Health University, Nagoya, Japan; 4Department of Molecular Pathology, Tokyo Medical University, Tokyo, Japan; 5Department of Ophthalmology, Japan Health Care Organization, Hoshigaoka Medical Center, Hirakata, Japan Purpose: Leukoplakia is the term given to a white patch or plaque that is found mainly on the oral mucus membrane. It can occasionally be seen on the corneal surface. We report our clinical and histopathological findings in a case of unilateral corneal leukoplakia. Methods: A 26-year-old woman was referred to our hospital because of a white patch on her right cornea that continued to expand. She first noticed the white patch when she was 20 years old, and the white patch had expanded to cover the pupillary area affecting her vision. After plastic surgery on both eyelids for bilateral entropion to alleviate the pain caused by the eyelashes rubbing the cornea, the white corneal patch decreased in size. Because of this reduction, we performed surgery to remove the patch with microforceps under topical anesthesia. The plaque was removed easily and completely, and submitted for histopathological examination. Results: Histopathological examination showed that the specimen had characteristics of epidermis with a basal cell layer, spinous cell layer, granular cell layer, and horny layer with hyperkeratosis. She was diagnosed with leukoplakia of the corneal surface. The basic structure of the squamous cell layer was preserved, and there were no signs of metaplasia. Six months after the removal of the leukoplakia, no recurrence was seen and her corrected decimal visual acuity recovered to 1

  19. Congenital hereditary endothelial dystrophy with progressive sensorineural deafness (Harboyan syndrome

    Directory of Open Access Journals (Sweden)

    Abramowicz Marc

    2008-10-01

    Full Text Available Abstract Harboyan syndrome is a degenerative corneal disorder defined as congenital hereditary endothelial dystrophy (CHED accompanied by progressive, postlingual sensorineural hearing loss. To date, 24 cases from 11 families of various origin (Asian Indian, South American Indian, Sephardi Jewish, Brazilian Portuguese, Dutch, Gypsy, Moroccan, Dominican have been reported. More than 50% of the reported cases have been associated with parental consanguinity. The ocular manifestations in Harboyan syndrome include diffuse bilateral corneal edema occurring with severe corneal clouding, blurred vision, visual loss and nystagmus. They are apparent at birth or within the neonatal period and are indistinguishable from those characteristic of the autosomal recessive CHED (CHED2. Hearing deficit in Harboyan is slowly progressive and typically found in patients 10–25 years old. There are no reported cases with prelinglual deafness, however, a significant hearing loss in children as young as 4 years old has been detected by audiometry, suggesting that hearing may be affected earlier, even at birth. Harboyan syndrome is caused by mutations in the SLC4A11 gene located at the CHED2 locus on chromosome 20p13-p12, indicating that CHED2 and Harboyan syndrome are allelic disorders. A total of 62 different SLC4A11 mutations have been reported in 98 families (92 CHED2 and 6 Harboyan. All reported cases have been consistent with autosomal recessive transmission. Diagnosis is based on clinical criteria, detailed ophthalmological assessment and audiometry. A molecular confirmation of the clinical diagnosis is feasible. A variety of genetic, metabolic, developmental and acquired diseases presenting with clouding of the cornea should be considered in the differential diagnosis (Peters anomaly, sclerocornea, limbal dermoids, congenital glaucoma. Audiometry must be performed to differentiate Harboyan syndrome from CHED2. Autosomal recessive types of CHED (CHED2 and

  20. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  1. Induction of corneal collagen cross-linking in experimental corneal alkali burns in rabbits

    Directory of Open Access Journals (Sweden)

    Marcello Colombo-Barboza

    2014-10-01

    Full Text Available Objective: To evaluate the effect of riboflavin-ultraviolet-A-induced cross-linking (CXL following corneal alkali burns in rabbits. Methods: The right corneas and limbi of ten rabbits were burned using a 1N solution of NaOH and the animals were then divided into two groups: a control group submitted to clinical treatment alone and an experimental group that was treated 1 h after injury with CXL, followed by the same clinical treatment as administered to the controls. Clinical parameters were evaluated post-injury at 1, 7, 15, and 30 days by two independent observers. Following this evaluation, the corneas were excised and examined histologically. Results: There were no statistically significant differences in clinical parameters, such as hyperemia, corneal edema, ciliary injection, limbal ischemia, secretion, corneal neovascularization, symblepharon, or blepharospasm, at any of the time-points evaluated. However, the size of the epithelial defect was significantly smaller in the CXL group (p<0.05 (day 15: p=0.008 and day 30: p=0.008 and the extent of the corneal injury (opacity lesion was also smaller (day 30: p=0.021. Histopathology showed the presence of collagen bridges linking the collagen fibers in only the CXL group. Conclusions: These results suggest that the use of CXL may improve the prognosis of acute corneal alkali burns.

  2. Application of Novel Drugs for Corneal Cell Regeneration

    Directory of Open Access Journals (Sweden)

    Sang Beom Han

    2018-01-01

    Full Text Available Corneal transplantation has been the only treatment method for corneal blindness, which is the major cause of reversible blindness. However, despite the advancement of surgical techniques for corneal transplantation, demand for the surgery can never be met due to a global shortage of donor cornea. The development of bioengineering and pharmaceutical technology provided us with novel drugs and biomaterials that can be used for innovative treatment methods for corneal diseases. In this review, the authors will discuss the efficacy and safety of pharmacologic therapies, such as Rho-kinase (ROCK inhibitors, blood-derived products, growth factors, and regenerating agent on corneal cell regeneration. The promising results of these agents suggest that these can be viable options for corneal reconstruction and visual rehabilitation.

  3. Effect of Cycloplegia on Corneal Biometrics and Refractive State.

    Science.gov (United States)

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( P biometrics should be considered before cataract and refractive surgeries.

  4. Posterior amorphous corneal dystrophy: case report

    OpenAIRE

    Oliveira, Lauro Augusto de [UNIFESP; Vieira, Luiz Antônio [UNIFESP; Freitas, Denise de [UNIFESP; Sousa, Luciene Barbosa de [UNIFESP

    2006-01-01

    O objetivo deste trabalho é alertar o oftalmologista da possibilidade de se deparar com casos raros de distrofias corneanas. Neste caso correlacionamos os achados clínicos da distrofia amorfa posterior com refração, topografia e biomicroscopia ultra-sônica.The purpose of this paper is to warn the ophthalmologist about the possibility of facing rare cases of corneal dystrophies. Clinical findings of a case of posterior amorphous dystrophy were correlated with refraction, topography, and ultras...

  5. RECURRENT CORNEAL EROSION SYNDROME (a review

    Directory of Open Access Journals (Sweden)

    S. V. Trufanov

    2015-01-01

    Full Text Available Recurrent corneal erosion (RCE syndrome is characterized by episodes of recurrent spontaneous epithelial defects. Main clinical symptoms (pain, redness, photophobia, lacrimation occurred at night. Corneal lesions revealed by slit lamp exam vary depending on the presence of corneal epithelium raise, epithelial microcysts or epithelial erosions, stromal infiltrates and opacities. Microtraumas, anterior corneal dystrophies, and herpesvirus give rise to RCE. Other causes or factors which increase the risk of RCE syndrome include meibomian gland dysfunction, keratoconjunctivitis sicca, diabetes, and post-LASIK conditions. Basal membrane abnormalities and instability of epithelial adhesion to stroma play a key role in RCE pathogenesis. Ultrastructural changes in RCE include abnormalities of basal epithelial cells and epithelial basal membrane, absence or deficiency of semi-desmosomes, loss of anchor fibrils. Increase in matrix metalloproteinases and collagenases which contribute to basal membrane destruction results in recurrent erosions and further development of abnormal basal membrane. The goals of RCE therapy are to reduce pain (in acute stage, to stimulate re-epithelization, and to restore «adhesion complex» of basal membrane. In most cases, RCE responds to simple conservative treatment that includes lubricants, healing agents, and eye patches. RCEs that are resistant to simple treatment, require complex approach. Non-invasive methods include long-term contact lens use, instillations of autologous serum (eye drops, injections of botulinum toxin (induces ptosis, antiviral agent use or oral intake of metalloproteinase inhibitors. Cell membrane stabilizers, i.e., antioxidants, should be included into treatment approaches as well. Antioxidant effect of Emoxipine promotes tissue reparation due to the prevention of cell membrane lipid peroxidation as well as due to its anti-hypoxic, angioprotective, and antiplatelet effects. If conservative therapy

  6. Corneal Collagen Cross-Linking with Hypoosmolar Riboflavin Solution in Keratoconic Corneas

    Directory of Open Access Journals (Sweden)

    Shaofeng Gu

    2014-01-01

    Full Text Available Purpose. To report the 12-month outcomes of corneal collagen cross-linking (CXL with a hypoosmolar riboflavin and ultraviolet-A (UVA irradiation in thin corneas. Methods. Eight eyes underwent CXL using a hypoosmolar riboflavin solution after epithelial removal. The corrected distance visual acuity (CDVA, manifest refraction, the mean thinnest corneal thickness (MTCT, and the endothelial cell density (ECD were evaluated before and 6 and 12 months after CXL. Results. The MTCT was 413.9 ± 12.4 μm before treatment and reduced to 381.1 ± 7.3 μm after the removal of the epithelium. After CXL, the thickness decreased to 410.3 ± 14.5 μm at the last follow-up. Before treatment, the mean K-value of the apex of the keratoconus corneas was 58.7 ± 3.5 diopters and slightly decreased (57.7 ± 4.9 diopters at 12 months. The mean CDVA was 0.54 ± 0.23 logarithm of the minimal angle of resolution before treatment and increased to 0.51 ± 0.21 logarithm at the last follow-up. The ECD was 2731.4 ± 191.8 cells/mm2 before treatment and was 2733.4 ± 222.6 cells/mm2 at 12 months after treatment. Conclusions. CXL with a hypoosmolar riboflavin in thin corneas seems to be a promising method for keratoconic eyes with the mean thinnest corneal thickness less than 400 μm without epithelium.

  7. Laser thermokeratoplasty after lamellar corneal cutting.

    Science.gov (United States)

    Ismail, M M; Pérez-Santonja, J J; Alió, J L

    1999-02-01

    To evaluate the effect of laser thermokeratoplasty (LTK) in eyes that previously had a lamellar corneal cut. University of Al-Azhar, Cairo, Egypt, and Instituto Oftalmológico de Alicante, Spain. In 15 eyes (10 patients), noncontact LTK was applied 6 to 8 weeks after a lamellar corneal cut had been made. Central pachymetry, keratometry, and videokeratography were performed and uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest and cycloplegic refractions measured before and 1, 6, 12, and 18 months after LTK. Mean follow-up was 19.13 months. Mean refraction was +5.93 diopters (D) +/- 1.9 (SD) before LTK and -0.43 +/- 1.5 D at 1 month, +1.63 +/- 1.6 D at 6 months, 1.91 +/- 1.41 at 12 months, and +2.01 +/- 1.5 D at the end of the study. Total regression did not occur in any case. Mean BSCVA before LTK was 0.66 +/- 0.2, and spontaneous visual acuity at the end of the study was 0.58 +/- 0.18. No patient lost any lines of preoperative BSCVA. There was no significant difference between the results at 12 months and at the end of the study. Corneal lamellar cutting appeared to improve the magnitude of the refractive effect of noncontact LTK and to decrease the amount of regression.

  8. Study on phototherapeutic keratotomy for bacterial corneal lesions in rabbit

    Directory of Open Access Journals (Sweden)

    Xin Zhou

    2018-05-01

    Full Text Available AIM: To study the effect of phototherapeutic keratectomy(PTKon rabbit bacterial corneal ulcer model and explore the clinical potential of this method. METHODS: Totally 48 eyes from all the 24 New Zealand rabbits were inoculated with Staphylococcus aureus and bacterial corneal ulcer model was established successfully. At 1d after inoculation, 48 eyes were given levofloxacin eye drops when corneal ulcer was confirmed. Then slit lamp inspection and optical coherence tomography(OCTwere performed to measure the central corneal ulcer depth. All the rabbits right eyes were treated with PTK, as an observation group, left eyes were not treated as a control group. The eye section were observed by slit lamp and central thickness of corneal ulcer was measured by OCT at 3 and 7d after this operation. Rabbits were sacrificed and the cornea was removed for pathological section 7d later. RESULTS: The corneal ulcers in both groups had a tendency to heal, showing a decrease in ulcer area and smoothness of the surface. There was no significant difference in the depth of corneal ulcer between the observation group and the control group before PTK(t=0.706, P=0.484. The difference between the two groups of eyes at 3 and 7d after PTK was obviously(PCONCLUSION: PTK can effectively cure rabbit Staphylococcus aureus corneal ulcer and promote ulcer wound healing, which may be used for clinical treatment of patients with bacterial corneal lesions.

  9. Administration of Menadione, Vitamin K3, Ameliorates Off-Target Effects on Corneal Epithelial Wound Healing Due to Receptor Tyrosine Kinase Inhibition.

    Science.gov (United States)

    Rush, Jamie S; Bingaman, David P; Chaney, Paul G; Wax, Martin B; Ceresa, Brian P

    2016-11-01

    The antiangiogenic receptor tyrosine kinase inhibitor (RTKi), 3-[(4-bromo-2,6-difluorophenyl)methoxy]-5-[[[[4-(1-pyrrolidinyl) butyl] amino] carbonyl]amino]-4-isothiazolecarboxamide hydrochloride, targets VEGFR2 (half maximal inhibitory concentration [IC50] = 11 nM); however, off-target inhibition of epidermal growth factor receptor (EGFR) occurs at higher concentrations. (IC50 = 5.8 μM). This study was designed to determine the effect of topical RTKi treatment on EGF-mediated corneal epithelial wound healing and to develop new strategies to minimize off-target EGFR inhibition. In vitro corneal epithelial wound healing was measured in response to EGF using a transformed human cell line (hTCEpi cells). In vivo corneal wound healing was assessed using a murine model. In these complementary assays, wound healing was measured in the presence of varying RTKi concentrations. Immunoblot analysis was used to examine EGFR and VEGFR2 phosphorylation and the kinetics of EGFR degradation. An Alamar Blue assay measured VEGFR2-mediated cell biology. Receptor tyrosine kinase inhibitor exposure caused dose-dependent inhibition of EGFR-mediated corneal epithelial wound healing in vitro and in vivo. Nanomolar concentrations of menadione, a vitamin K3 analog, when coadministered with the RTKi, slowed EGFR degradation and ameliorated the inhibitory effects on epithelial wound healing both in vitro and in vivo. Menadione did not alter the RTKi's IC50 against VEGFR2 phosphorylation or its inhibition of VEGF-induced retinal endothelial cell proliferation. An antiangiogenic RTKi exhibited off-target effects on the corneal epithelium that can be minimized by menadione without deleteriously affecting its on-target VEGFR2 blockade. These data indicate that menadione has potential as a topical supplement for individuals suffering from perturbations in corneal epithelial homeostasis, especially as an untoward side effect of kinase inhibitors.

  10. Unilateral Posterior Polymorphous Corneal Dystrophy Presented as Anisometropic Astigmatism: 3 Case Reports

    Directory of Open Access Journals (Sweden)

    Hyun Sun Jeon

    2017-04-01

    Full Text Available Background: Posterior polymorphous corneal dystrophy (PPCD is typically considered bilateral and asymptomatic. However, few case reports on patients with unilateral PPCD with asymmetric refractive error have mentioned anisometropic amblyopia development. In support of this, we report 3 cases of unilateral PPCD that presented as anisometropic astigmatism. Visual prognosis related to amblyopia development is discussed. Case Presentation: All 3 patients had a band lesion in the affected eye and a difference of at least 1.5 diopters in cylindrical refractive error between their eyes. The affected eye had a greater amount of astigmatism in all cases. Two patients (Cases 1 and 2 also had amblyopia in the affected eye. Case 1 was a 25-year-old male with a unilateral PPCD diagnosis and a band lesion involving the visual axis. Case 2 was an 11-year-old boy diagnosed with unilateral PPCD. The boy was treated with occlusion and atropine therapy over a 2-year period. Case 3 was a 4-year-old girl diagnosed with unilateral PPCD. The girl had a 30-month history of corrective spectacle use and had no amblyopia. In all cases, the corneal endothelial cell count was lower in the affected eye than in the unaffected contralateral eye. Conclusions: Practitioners should closely monitor patients with unilateral PPCD for astigmatic anisometropia and amblyopia development. Visual prognosis for patients with unilateral PPCD may be related to lesion position, age at diagnosis, astigmatism severity, and early-childhood corrective spectacle use.

  11. MMSC-LIKE LIMBAL CELLS COTRANSPLANTATION PROMOTES LOCAL IMMUNOCORRECTION AND CORNEAL GRAFT TRANSPARENT RETENTION IN HIGH RISK KERATOPLASTY

    Directory of Open Access Journals (Sweden)

    S. A. Borzenok

    2014-01-01

    Full Text Available Aim was to evaluate clinical results of donor corneal graft survival in high-risk recipients in co-transplantation of preserved allogenic limbal grafts. Materials and methods. Two types of penetrative keratoplasties were carried out in patients with corneal graft opacities and high risk of rejection (n = 69. Co-transplantation of donor cornea and allogenic MMSC-like limbal cells in the form of limbal transplants was carried out in the 1st group (n = 36; in the 2nd group (n = 33 only the cornea was transplanted. Results. Observation of the patients during one year after surgery showed that the rate of transparent cornea engraftment increased in the 1st group (86,1 against 69,7% in the 2nd group. The density of endothelial cells was also higher in the 1st group (85,9 against 76,2% in the 2nd group. At the same time, progressive decreasing of pro-inflammatory cytokines (IL-6, IFNγ, TNFα and increasing of anti-inflammatory cytokines (IL-10, IL-1RA, TGFβ along with higher level of HLA-G5 were revealed in the recipients’ tear fluid in the 1st group in comparison to the 2nd group. Conclusion. Simultaneous transplantation of preserved limbal grafts with corneal graft in high-risk keratoplasty favors the transparent cornea engraftment, obviously, this is due to immunoregulatory activity of the MMSC-like limbal cells. 

  12. [Circulating endothelial cells: biomarkers for monitoring activity of antiangiogenic therapy].

    Science.gov (United States)

    Farace, Françoise; Bidart, Jean-Michel

    2007-07-01

    Tumor vessel formation is largely dependent on the recruitment of endothelial cells. Rare in healthy individuals, circulating endothelial cells (CEC) are shed from vessel walls and enter the circulation reflecting endothelial damage or dysfunction. Increased numbers of CEC have been documented in different types of cancer. Recent studies have suggested the role for CEC in tumor angiogenesis, but whose presence could also reflect normal endothelium perturbation in cancer. Originating from the bone marrow rather than from vessel walls, endothelial progenitor cells (EPC) are mobilized following tissue ischemia and may be recruited to complement local angiogenesis supplied by existing endothelium. Recently, studies in mouse models suggest that the circulating fraction of endothelial progenitors (CEP) is involved in tumor angiogenesis but their contribution is less clear in humans. The detection of CEC and CEP is difficult and impeded by the rarity of these cells. They may have important clinical implication as novel biomarkers susceptible to predict more efficiently and rapidly the therapeutic response to anti-angiogenic treatments. However, a methodological consensus would be necessary in order to correctly evaluate the clinical interest of CEC and CEP in patients.

  13. Effect of sunitinib combined with ionizing radiation on endothelial cells

    International Nuclear Information System (INIS)

    Zhang Haiping; Jiao Xiaodong; Li Rui; Wang Jiejun; Takayama, Koichi; Su Bo

    2011-01-01

    The aims of present study were to evaluate the efficacy of combining sunitinib with ionizing radiation (IR) on endothelial cells in vitro and in vivo. Human umbilical vein endothelial cells (HUVECs) were exposed to IR with or without sunitinib pretreatment. Apoptosis assay and cell cycle distribution were analyzed by flow cytometry. Clonogenic survival assay at 3 Gy dose with or without sunitinib was performed. The activity of phosphatidylinositol 3-kinase (PI3K)/Akt signal pathway was detected by Western immunoblot. Lewis lung carcinoma mouse model was built to examine the effect of combination therapy on endothelial cells in vivo. Microvasculature changes were detected by immunohistochemistry using anti-CD31 antibody. Our results showed combination therapy of sunitinib and IR significantly increased apoptosis of endothelial cells and inhibited colony formation compared to sunitinib or radiotherapy alone. It also resulted in cell cycle redistribution (decreasing cells in S phase and increasing cells in G2/M phase). The activity of PI3K/Akt signal pathway was inhibited, which could be the potential mechanisms that account for the enhanced radiation response induced by sunitinib. In vivo analysis showed that combination therapy significantly decreased microvasculature formation. The results demonstrated that combination therapy of sunitinib and IR has the potential to increase the cytotoxic effects on endothelial cells. (author)

  14. A two-year's results of iontophoresis-assisted transepithelial corneal cross-linking for progressive keratoconus

    Directory of Open Access Journals (Sweden)

    Hong-Zhen Jia

    2016-07-01

    Full Text Available AIM: To report a two-year's results of iontophoresis-assisted transepithelial corneal cross-linking(I-CXLfor progressive keratoconus. METHODS: Thirty-four eyes in 24 patients with progressive keratoconus(mean age 21.0±5.6 years; range: 14-32 yearswere treated. After 1g/L riboflavin-distilled water solution was administered by iontophoresis-assited(current 1mAtransepithelial method for 5min in total, standard surface UVA irradiation(370nm, 3mW/cm2was performed at a 1-cm distance for 30min. The best corrected visual acuity(BCVAmeasured as LogMAR number, corneal refractive astigmatism, K1, K2, Kmean, Kmax, intraocular pressure, endothelial cell density, the thickness at corneal apex and the thinnest point were measured preoperatively and 2a postoperatively. RESULTS:At 2a after the procedure, BCVA(LogMARimproved from 0.32±0.25 to 0.25±0.19(t=2.849, P=0.015. K1 decreased from 47.12±4.33 to 46.06±4.77(t=2.652, P=0.015. K2 decreased from 51.36±5.59 to 50.40±6.16(t=2.121, P=0.047. Kmean decreased from 49.12±4.76 to 48.10±5.25(t=2.663, P=0.015. Kmax decreased from 57.57±8.30 to 55.91±8.14(t=2.398, P=0.026. The corneal apex thickness decreased from 476.90±38.71μm to 454.43±40.86μm(t=2.853, P=0.010. The thinnest thickness decreased from 464.38±39.92μm to 433.86±50.78μm(t=3.485, P=0.002. Corneal refractive astigmatism, intraocular pressure and endothelial cell density did not show significant changes. CONCLUSION: I-CXL for progressive keratoconus is safe and effective which can prevent deterioration of progressive keratoconus within 2a, but further long-term studies are necessary still.

  15. Corneal tissue welding with infrared laser irradiation after clear corneal incision.

    Science.gov (United States)

    Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat

    2010-09-01

    The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

  16. Hydrogen sulfide metabolism regulates endothelial solute barrier function

    Directory of Open Access Journals (Sweden)

    Shuai Yuan

    2016-10-01

    Full Text Available Hydrogen sulfide (H2S is an important gaseous signaling molecule in the cardiovascular system. In addition to free H2S, H2S can be oxidized to polysulfide which can be biologically active. Since the impact of H2S on endothelial solute barrier function is not known, we sought to determine whether H2S and its various metabolites affect endothelial permeability. In vitro permeability was evaluated using albumin flux and transendothelial electrical resistance. Different H2S donors were used to examine the effects of exogenous H2S. To evaluate the role of endogenous H2S, mouse aortic endothelial cells (MAECs were isolated from wild type mice and mice lacking cystathionine γ-lyase (CSE, a predominant source of H2S in endothelial cells. In vivo permeability was evaluated using the Miles assay. We observed that polysulfide donors induced rapid albumin flux across endothelium. Comparatively, free sulfide donors increased permeability only with higher concentrations and at later time points. Increased solute permeability was associated with disruption of endothelial junction proteins claudin 5 and VE-cadherin, along with enhanced actin stress fiber formation. Importantly, sulfide donors that increase permeability elicited a preferential increase in polysulfide levels within endothelium. Similarly, CSE deficient MAECs showed enhanced solute barrier function along with reduced endogenous bound sulfane sulfur. CSE siRNA knockdown also enhanced endothelial junction structures with increased claudin 5 protein expression. In vivo, CSE genetic deficiency significantly blunted VEGF induced hyperpermeability revealing an important role of the enzyme for barrier function. In summary, endothelial solute permeability is critically regulated via exogenous and endogenous sulfide bioavailability with a prominent role of polysulfides.

  17. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    Science.gov (United States)

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  18. Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

    Science.gov (United States)

    Hamed-Azzam, Shirin; Briscoe, Daniel; Tomkins, Oren; Shehedeh-Mashor, Raneen; Garzozi, Hanna

    2013-08-01

    Intraocular pressure is affected by corneal thickness and biomechanics. Following ablative corneal refractive surgery, corneal structural changes occur. The purpose of the study is to determine the relationship between the mean central corneal thickness (CCT) and the change in intraocular pressure measurements following various corneal ablation techniques, using different measurement methods. Two hundred myopic eyes undergoing laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) were enrolled into a prospective, non-randomized study. Corneal parameters examined included full ocular examination, measurement of CCT, corneal topography, corneal curvature and ocular refractivity. Intraocular pressure measurements were obtained using three different instruments-non-contact tonometer, Goldmann applanation tonometer and TonoPen XL (TonoPen-Central and TonoPen-Peripheral). All measurements were performed pre-operatively and 4 months post-operatively. Post-operative intraocular pressure was significantly lower than pre-operative values, with all instruments (p value tonometer and non-contact tonometer (p value < 0.001, ANOVA). Intraocular pressure readings are significantly reduced following corneal ablation surgery. We determined in our myopic patient cohort that the TonoPen XL intraocular pressure measurement method is the least affected following PRK and LASIK as compared to other techniques.

  19. Two cases of corneal perforation after oral administration of nonsteroidal anti-inflammatory drugs: oral NSAID-induced corneal damage.

    Science.gov (United States)

    Masuda, Ikuya; Matsuo, Toshihiko; Okamoto, Kazuo; Matsushita, Kyoko; Ohtsuki, Hiroshi

    2010-01-01

    To report 2 cases of corneal perforation associated with the use of oral nonsteroidal anti-inflammatory drugs (NSAIDs). In a 62-year-old woman and a 79-year-old woman, corneal perforation occurred after 7 days and 5 months of oral NSAIDs administration, respectively. After NSAIDs were discontinued, the cornea epithelialized and the anterior chamber formed within 14 and 10 days, respectively. It is well known that topical NSAIDs cause corneal perforation. Observations in the present cases suggest that the oral administration of NSAIDs may also cause corneal damage, and hence, medical professionals should consider the risk of damage to the cornea when administering these drugs orally.

  20. Ultrastructural morphology and morphometry of the normal corneal endothelium of adult crossbred pig Morfologia ultraestrutural e morfometria do endotélio corneal normal de suínos adultos mestiços

    Directory of Open Access Journals (Sweden)

    Lynda Jhailú Tamayo-Arango

    2009-02-01

    Full Text Available Corneal endothelium constitutes a monolayer of polygonal cells. The integrity and health of this layer are essential for the maintenance of normal corneal transparency. This study reported by the first time in a detailed way the ultrastructural morphology and morphometry of the corneal endothelium in normal adult crossbred pigs by using scanning electron microscopy (SEM. A regular pattern of polygonal cells, with predominantly hexagonal cells and clear cell borders, was observed. An oval nucleus that bulges in the centre of the cell, cilia (2-4 in a few peripheral cells, openings of the pinocytotic vesicles, microvilli, borders bars and interdigitated cell borders were observed. The mean endothelial cell area was significantly higher (PO endotélio corneal é uma monocamada de células poligonais. A integridade e saúde dessa camada são essenciais para a manutenção da transparência corneal normal. Este estudo reportou pela primeira vez, de forma detalhada, a morfologia ultra-estrutural e a morfometria do endotélio corneal de suínos adultos mestiços à microscopia eletrônica de varredura (MEV. A superfície endothelial corneal apresentou um padrão regular de células poligonais, com predomínio da forma hexagonal e de bordas celulares nítidas. O núcleo foi observado como protuberância arredondada no centro da célula. Também foram observados os cílios (2-4 em apenas algumas células da região periférica da córnea, as aberturas das vesículas pinocitóticas na proximidade dos cílios, as microvilosidades, as varas da borda e as bordas celulares em formato de zigzag. A área celular média foi significativamente maior (P<0,05 no centro da córnea do que na periferia, com um coeficiente de variação menor no centro da córnea. A densidade celular média foi significativamente maior na periferia (P<0,05 e 43,9% maior que os dados reportados por outros autores na microscopia especular, o que demonstra o efeito da retração celular

  1. Corneal donations in South Africa: A 15-year review.

    Science.gov (United States)

    York, Nicholas J; Tinley, Christopher

    2017-07-28

    Corneal pathology is one of the leading causes of preventable blindness in South Africa (SA). A corneal transplant can restore or significantly improve vision in most cases. However, in SA there is a gross shortage of corneal tissue available to ophthalmologists. Little has been published describing the magnitude of the problem. To describe trends in the number of corneal donors per year in SA, the number of corneal transplants performed each year, the origin of donors, the allocation of corneas to the public or private sector, and the demographics of donors. This was a retrospective review of all corneal donations to SA eye banks over the 15-year period 1 January 2002 - 31 December 2016. There was a progressive year-on-year decline in corneal donors over the study period, from 565 per year in 2002 to 89 in 2016. As a direct result, there has been an 85.5% decrease in the number of corneal transplants performed per year using locally donated corneas, from 1 049 in 2002 to 152 in 2016. Of the donors, 48.8% originated from mortuaries, 39.0% from private hospitals and 12.2% from government hospitals; donors from mortuaries showed the most significant decline over the 15-year period, decreasing by 94.8%. Of donated corneas, 79.3% were allocated to the private sector and 21.7% to the public sector. Males comprised 69.1% of donors, while 77.2% were white, 14.0% coloured, 6.3% black and 2.5% Indian/Asian. Donor age demonstrated a bimodal peak at 25 and 55 years. The number of corneal donations in SA has declined markedly, causing the burden of corneal disease requiring transplantation to rise steadily. Population groups with a low donor rate may have cultural and other objections to corneal donation, which should be a major focus of future research and initiatives aimed at reversing the current trends.

  2. Mouse adhalin

    DEFF Research Database (Denmark)

    Liu, L; Vachon, P H; Kuang, W

    1997-01-01

    . To analyze the biological roles of adhalin, we cloned the mouse adhalin cDNA, raised peptide-specific antibodies to its cytoplasmic domain, and examined its expression and localization in vivo and in vitro. The mouse adhalin sequence was 80% identical to that of human, rabbit, and hamster. Adhalin...... was specifically expressed in striated muscle cells and their immediate precursors, and absent in many other cell types. Adhalin expression in embryonic mouse muscle was coincident with primary myogenesis. Its expression was found to be up-regulated at mRNA and protein levels during myogenic differentiation...

  3. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

    Science.gov (United States)

    Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward

    2015-01-01

    To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  4. Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies

    Directory of Open Access Journals (Sweden)

    Anna K. Nowinska

    2015-01-01

    Full Text Available Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT in eyes with corneal dystrophies (CDs. Methods. Fifty healthy volunteers (50 eyes and 54 patients (96 eyes diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT, anterior chamber depth (ACD, and nasal and temporal trabecular iris angle (nTIA, tTIA were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.

  5. Descemet's membrane endothelial keratoplasty surgery: update on the evidence and hurdles to acceptance.

    Science.gov (United States)

    Price, Marianne O; Price, Francis W

    2013-07-01

    Descemet's stripping endothelial keratoplasty (DSEK) is the most popular treatment for endothelial dysfunction, but Descemet's membrane endothelial keratoplasty (DMEK) now provides better vision with lower risk of immunologic rejection. Although DMEK is more challenging, advances in instrumentation and techniques are reducing the learning curve. In contrast to DSEK, which includes posterior donor stroma, DMEK consists merely of donor endothelium and Descemet's membrane, so DMEK does not create a stromal interface and induces significantly less posterior surface aberrations, resulting in better vision. Furthermore, multiple centers report remarkably low (<1%) cumulative probability of immunologic graft rejection episodes through 2 years after DMEK. Initially, the biggest challenges were tissue loss in preparation and ensuring attachment. Subsequent improvements have reduced complication rates to levels experienced with DSEK. DMEK/DSEK hybrids and 'thin' DSEK also can provide better vision than standard DSEK; randomized controlled comparisons with DMEK are needed. DMEK provides an anatomically exact replacement of dysfunctional host endothelium and has set new benchmarks for rejection risk and visual outcomes following endothelial replacement. DMEK is providing new insights into how different corneal layers contribute to immunogenicity and immune tolerance and into the key factors that limit vision after endothelial keratoplasty.

  6. Collagen VII deficient mice show morphologic and histologic corneal changes that phenotypically mimic human dystrophic epidermolysis bullosa of the eye.

    Science.gov (United States)

    Chen, Vicki M; Shelke, Rajani; Nyström, Alexander; Laver, Nora; Sampson, James F; Zhiyi, Cao; Bhat, Najma; Panjwani, Noorjahan

    2018-06-16

    Absence of collagen VII causes blistering of the skin, eyes and many other tissues. This disease is termed dystrophic epidermolysis bullosa (DEB). Corneal fibrosis occurs in up to 41% and vision loss in up to 64% of patients. Standard treatments are supportive and there is no cure. The immune-histologic and morphologic changes in the corneas of the mouse model for this disease have not been described in the literature. Our purpose is to characterize the eyes of these mice to determine if this is an appropriate model for study of human therapeutics. Western blot analysis (WB) and immunohistochemistry (IHC) were performed to assess the relative collagen VII protein levels and its location within the cornea. Additional IHC for inflammatory and fibrotic biomarkers alpha-smooth muscle actin (α-SMA), transforming growth factor-beta (TGF-β), connective tissue growth factor (CTGF), proteinase 3, tenascin C and collagen III were performed. Clinical photographs documenting opacification of the corneas of animals of differing ages were assessed and scored independently by 2 examiners. Histology was then used to investigate morphologic changes. IHC and WB confirmed that these mice are deficient in collagen VII production at the level of the basement membrane when compared with wild-types. IHC showed anomalous deposition of collagen III throughout the stroma. Of the 5 biomarkers tested, TGF-β showed the strongest and most consistently staining. Photographs documented corneal opacities only in mice older than 10 weeks, opacities were not seen in younger animals. Histology showed multiple abnormalities, including epithelial hyperplasia, ulceration, fibrosis, edema, dysplasia, neovascularization and bullae formation. The collagen VII hypomorphic mouse shows reduced collagen VII production at the level of the corneal basement membrane. Corneal changes are similar to pathology seen in humans with this disease. The presence of anomalous stromal collagen III and TGF-β appear to be

  7. Endothelial RIG-I activation impairs endothelial function

    Energy Technology Data Exchange (ETDEWEB)

    Asdonk, Tobias, E-mail: tobias.asdonk@ukb.uni-bonn.de [Department of Medicine/Cardiology, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn (Germany); Motz, Inga; Werner, Nikos [Department of Medicine/Cardiology, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn (Germany); Coch, Christoph; Barchet, Winfried; Hartmann, Gunther [Institute for Clinical Chemistry and Clinical Pharmacology, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn (Germany); Nickenig, Georg; Zimmer, Sebastian [Department of Medicine/Cardiology, University of Bonn, Sigmund-Freud-Str. 25, 53105 Bonn (Germany)

    2012-03-30

    Highlights: Black-Right-Pointing-Pointer RIG-I activation impairs endothelial function in vivo. Black-Right-Pointing-Pointer RIG-I activation alters HCAEC biology in vitro. Black-Right-Pointing-Pointer EPC function is affected by RIG-I stimulation in vitro. -- Abstract: Background: Endothelial dysfunction is a crucial part of the chronic inflammatory atherosclerotic process and is mediated by innate and acq