WorldWideScience

Sample records for mouse bioassay hplc

  1. Use of cyanopropyl-bonded hplc column for bioassay-directed fractionation of organic extracts from incinerator emissions

    International Nuclear Information System (INIS)

    DeMarini, D.M.; Williams, R.W.; Brooks, L.R.; Taylor, M.S.

    1992-01-01

    The present study has shown that cyanopropyl-(CN) bonded silica HPLC columns are applicable for the fractionation of mass and mutagenic activity of organic extracts from some incinerator emissions. Dichloromethane-extractable organics from particles emitted by two different municipal waste incinerators and by a pilot-scale rotary kiln incinerator that was combusting polyethylene were fractionated by HPLC, and the mutagenicity of the fractions was determined by means of a microsuspension mutagenicity assay with Salmonella TA98. The CN-bonded silica columns provided high (80-100 percent) mass and mutagenicity recoveries for most emission extracts, and it fractionated the mutagenic activity. The results suggest that the emissions from municipal waste incinerators contain a high amount of direct-acting (-S9) mutagenic activity that is resolvable by HPLC using CN-bonded silica. Sub-fractionation of selected mutagenic HPLC fractions and subsequent analysis by gas chromatography/mass spectroscopy can be used to identify mutagenic species within complex incinerator emissions. The coupling of microsuspension bioassays to HPLC fractionation should be a useful tool for this type of analysis

  2. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    Science.gov (United States)

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  3. Potency determination of follitropin, lutropin And thyrotropin: a comparison between the quantification by reversed-phase high-performance liquid chromatography and in vivo bioassay

    International Nuclear Information System (INIS)

    Almeida, Beatriz Elane de

    2013-01-01

    With the intention of setting up physico-chemical methods as an alternative to in vivo bioassay for determining biological activity, the hFSH, hTSH and hLH content of native and recombinant preparations was determined by reversed-phase high-performance liquid chromatography (RP-HPLC) and compared with the data obtained by the classical mouse or rat in vivo bioassays (BA). A linear relationship between the two methods was found for these hormones: hFSH BA U= 0.9925 RP-HPLC U– 1.3165, r = 0.9371, p IU = 0.8771 RP-HPLC IU + 12.41, r = 0.9786, p < 0.01, n = 5. For nine other hFSH and eleven hTSH preparations, the mean difference ( ) between the bioactivity predicted from RP-HPLC data via these equations and the mean of the bioactivities obtained with the two methods was as follows. For hLH this difference could not be estimated due to lack of different samples. In the case of hFSH, ± SD = -2.11 ± 3.49% with a precision of 1.16% and in the case of hTSH, ± SD = -2.01 ± 5.56 %, with precision of 1.68%. Partly-degraded hFSH, hTSH and hLH samples presented different activity degrees that could be predicted by RP-HPLC, with an acceptable agreement with the in vivo bioassays. These results demonstrate that the employment of a non-animal physico-chemical assay, such as RP-HPLC, is a viable alternative to the use of an in vivo bioassay for hFSH and hTSH potency determination, thus reducing the number of animals currently used for assuring quality and efficacy of a pharmaceutical product. (author)

  4. Development and validation of microbial bioassay for quantification of Levofloxacin in pharmaceutical preparations

    Directory of Open Access Journals (Sweden)

    Nishant A. Dafale

    2015-02-01

    Full Text Available The aim of this study was to develop and validate a simple, sensitive, precise and cost-effective one-level agar diffusion (5+1 bioassay for estimation of potency and bioactivity of Levofloxacin in pharmaceutical preparation which has not yet been reported in any pharmacopoeia. Among 16 microbial strains, Bacillus pumilus ATCC-14884 was selected as the most significant strain against Levofloxacin. Bioassay was optimized by investigating several factors such as buffer pH, inoculums concentration and reference standard concentration. Identification of Levofloxacin in commercial sample Levoflox tablet was done by FTIR spectroscopy. Mean potency recovery value for Levofloxacin in Levoflox tablet was estimated as 100.90%. A validated bioassay method showed linearity (r2=0.988, precision (Interday RSD=1.05%, between analyst RSD=1.02% and accuracy (101.23%, RSD=0.72%. Bioassay was correlated with HPLC using same sample and estimated potencies were 100.90% and 99.37%, respectively. Results show that bioassay is a suitable method for estimation of potency and bioactivity of Levofloxacin pharmaceutical preparations. Keywords: Levofloxacin, Antibiotic resistance, Microbiological bioassay, HPLC, Pharmacopoeia

  5. Potency determination of follitropin, lutropin And thyrotropin: a comparison between the quantification by reversed-phase high-performance liquid chromatography and in vivo bioassay; Determinacao de potencia de diferentes preparacoes de foliculotrofina, luteotrofina e tireotrofina: comparacao entre a quantificacao por cromatografia liquida em fase reversa e por bioensaio in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Beatriz Elane de

    2013-07-01

    With the intention of setting up physico-chemical methods as an alternative to in vivo bioassay for determining biological activity, the hFSH, hTSH and hLH content of native and recombinant preparations was determined by reversed-phase high-performance liquid chromatography (RP-HPLC) and compared with the data obtained by the classical mouse or rat in vivo bioassays (BA). A linear relationship between the two methods was found for these hormones: hFSH BA{sub U=} 0.9925 RP-HPLC{sub U–} 1.3165, r = 0.9371, p < 0.001, n = 24; hTSH BAμg = 0.9790 RP-HPLCμg - 0.052, r = 0.8725, p < 0.001, n = 14; hLH BA{sub IU} = 0.8771 RP-HPLC{sub IU} + 12.41, r = 0.9786, p < 0.01, n = 5. For nine other hFSH and eleven hTSH preparations, the mean difference ( ) between the bioactivity predicted from RP-HPLC data via these equations and the mean of the bioactivities obtained with the two methods was as follows. For hLH this difference could not be estimated due to lack of different samples. In the case of hFSH, ± SD = -2.11 ± 3.49% with a precision of 1.16% and in the case of hTSH, ± SD = -2.01 ± 5.56 %, with precision of 1.68%. Partly-degraded hFSH, hTSH and hLH samples presented different activity degrees that could be predicted by RP-HPLC, with an acceptable agreement with the in vivo bioassays. These results demonstrate that the employment of a non-animal physico-chemical assay, such as RP-HPLC, is a viable alternative to the use of an in vivo bioassay for hFSH and hTSH potency determination, thus reducing the number of animals currently used for assuring quality and efficacy of a pharmaceutical product. (author)

  6. A rapid bioassay for detecting saxitoxins using a Daphnia acute toxicity test

    Energy Technology Data Exchange (ETDEWEB)

    Ferrao-Filho, Aloysio da S., E-mail: aloysio@ioc.fiocruz.b [Laboratorio de Avaliacao e Promocao da Saude Ambiental, Departamento de Biologia, Instituto Oswaldo Cruz, FIOCRUZ, Av. Brasil 4365, Manguinhos, Rio de Janeiro, RJ 21045-900 (Brazil); Soares, Maria Carolina S., E-mail: mcarolsoares@gmail.co [Departamento de Engenharia Sanitaria e Ambiental Faculdade de Engenharia, Universidade Federal de Juiz de Fora, Juiz de Fora, MG 36036-900 (Brazil); Freitas de Magalhaes, Valeria, E-mail: valeria@biof.ufrj.b [Laboratorio de Ecofisiologia e Toxicologia de Cianobacterias, Instituto de Biofisica Carlos Chagas Filho, CCS, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Rio de Janeiro, RJ 21949-900 (Brazil); Azevedo, Sandra M.F.O., E-mail: sazevedo@biof.ufrj.b [Laboratorio de Ecofisiologia e Toxicologia de Cianobacterias, Instituto de Biofisica Carlos Chagas Filho, CCS, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Rio de Janeiro, RJ 21949-900 (Brazil)

    2010-06-15

    Bioassays using Daphnia pulex and Moina micrura were designed to detect cyanobacterial neurotoxins in raw water samples. Phytoplankton and cyanotoxins from seston were analyzed during 15 months in a eutrophic reservoir. Effective time to immobilize 50% of the exposed individuals (ET{sub 50}) was adopted as the endpoint. Paralysis of swimming movements was observed between approx0.5-3 h of exposure to lake water containing toxic cyanobacteria, followed by an almost complete recovery of the swimming activity within 24 h after being placed in control water. The same effects were observed in bioassays with a saxitoxin-producer strain of Cylindrospermopsis raciborskii isolated from the reservoir. Regression analysis showed significant relationships between ET{sub 50}vs. cell density, biomass and saxitoxins content, suggesting that the paralysis of Daphnia in lake water samples was caused by saxitoxins found in C. raciborskii. Daphnia bioassay was found to be a sensitive method for detecting fast-acting neurotoxins in natural samples, with important advantages over mouse bioassays. - A new Daphnia bioassay, as an alternative to the mouse bioassay, is able to detect effects of fast-acting, potent neurotoxins in raw water.

  7. A rapid bioassay for detecting saxitoxins using a Daphnia acute toxicity test

    International Nuclear Information System (INIS)

    Ferrao-Filho, Aloysio da S.; Soares, Maria Carolina S.; Freitas de Magalhaes, Valeria; Azevedo, Sandra M.F.O.

    2010-01-01

    Bioassays using Daphnia pulex and Moina micrura were designed to detect cyanobacterial neurotoxins in raw water samples. Phytoplankton and cyanotoxins from seston were analyzed during 15 months in a eutrophic reservoir. Effective time to immobilize 50% of the exposed individuals (ET 50 ) was adopted as the endpoint. Paralysis of swimming movements was observed between ∼0.5-3 h of exposure to lake water containing toxic cyanobacteria, followed by an almost complete recovery of the swimming activity within 24 h after being placed in control water. The same effects were observed in bioassays with a saxitoxin-producer strain of Cylindrospermopsis raciborskii isolated from the reservoir. Regression analysis showed significant relationships between ET 50 vs. cell density, biomass and saxitoxins content, suggesting that the paralysis of Daphnia in lake water samples was caused by saxitoxins found in C. raciborskii. Daphnia bioassay was found to be a sensitive method for detecting fast-acting neurotoxins in natural samples, with important advantages over mouse bioassays. - A new Daphnia bioassay, as an alternative to the mouse bioassay, is able to detect effects of fast-acting, potent neurotoxins in raw water.

  8. Real-time PCR for the early detection and quantification of Coxiella burnetii as an alternative to the murine bioassay.

    Science.gov (United States)

    Howe, Gerald B; Loveless, Bonnie M; Norwood, David; Craw, Philip; Waag, David; England, Marilyn; Lowe, John R; Courtney, Bernard C; Pitt, M Louise; Kulesh, David A

    2009-01-01

    Real-time PCR was used to analyze archived blood from non-human primates (NHP) and fluid samples originating from a well-controlled Q fever vaccine efficacy trial. The PCR targets were the IS1111 element and the com1 gene of Coxiella burnetii. Data from that previous study were used to evaluate real-time PCR as an alternative to the use of sero-conversion by mouse bioassay for both quantification and early detection of C. burnetii bacteria. Real-time PCR and the mouse bioassay exhibited no statistical difference in quantifying the number of microorganisms delivered in the aerosol challenge dose. The presence of C. burnetii in peripheral blood of non-human primates was detected by real-time PCR as early after exposure as the mouse bioassay with results available within hours instead of weeks. This study demonstrates that real-time PCR has the ability to replace the mouse bioassay to measure dosage and monitor infection of C. burnetii in a non-human primate model.

  9. Genetic mouse embryo assay: improving performance and quality testing for assisted reproductive technology (ART) with a functional bioassay.

    Science.gov (United States)

    Gilbert, Rebecca S; Nunez, Brandy; Sakurai, Kumi; Fielder, Thomas; Ni, Hsiao-Tzu

    2016-03-24

    Growing concerns about safety of ART on human gametes, embryos, clinical outcomes and long-term health of offspring require improved methods of risk assessment to provide functionally relevant assays for quality control testing and pre-clinical studies prior to clinical implementation. The one-cell mouse embryo assay (MEA) is the most widely used for development and quality testing of human ART products; however, concerns exist due to the insensitivity/variability of this bioassay which lacks standardization and involves subjective analysis by morphology alone rather than functional analysis of the developing embryos. We hypothesized that improvements to MEA by the use of functional molecular biomarkers could enhance sensitivity and improve detection of suboptimal materials/conditions. Fresh one-cell transgenic mouse embryos with green fluorescent protein (GFP) expression driven by Pou6f1 or Cdx2 control elements were harvested and cultured to blastocysts in varied test and control conditions to compare assessment by standard morphology alone versus the added dynamic expression of GFP for screening and selection of critical raw materials and detection of suboptimal culture conditions. Transgenic mouse embryos expressing functionally relevant biomarkers of normal early embryo development can be used to monitor the developmental impact of culture conditions. This novel approach provides a superior MEA that is more meaningful and sensitive for detection of embryotoxicity than morphological assessment alone.

  10. PCR und ELISA - Alternativen zum Maustest für die Analyse des Botulismus-Neurotoxin-C1 Giftbildungspotentiales in Umweltproben? [PCR and ELISA - in vitro alternatives to the mouse-bioassay for assessing the botulinum-neurotoxin-C1 production potential in environmental samples?

    Science.gov (United States)

    Zechmeister, T.C.; Farnleitner, A.H.; Rocke, T.E.; Pittner, F.; Rosengarten, R.; Mach, R.L.; Herzig, A.; Kirschner, A.K.T.

    2002-01-01

    Botulism is one of the most important bird diseases world-wide and is caused by the intoxication with Botulinum-Neurotoxin-C1 (BoNt-C1), which is produced by toxigenic clostridia under appropriate conditions. Avian botulism leads regularly to large losses among the migrating bird populations breeding and resting at the saltwater pools of the Austrian national park Neusiedler See-Seewinkel. Despite of its ethical dubiousness and its high technical expense the mouse-bioassay is still used as the routine standard method for the detection of BoNt-C1. According to the 3R-concept, in vitro alternative methods for the qualitative detection of BoNt-C1 (immunostick-ELISA) and a corresponding BoNt-C1 gene fragment (nested-PCR) were established. In order to estimate the BoNt-C1 production potential the methods were tested with sediment samples from different saltwater pools subjected to cultivation conditions appropriate for in vitro BoNt-C1-production. With the mouse-bioassay, 52 out of 77 samples were found to have a positive toxin production potential. The immunostick-ELISA showed a similar sensitivity as the mouse-bioassay and exhibited a highly significant positive correlation (r=0.94; pELISA (r=0.09; p=0.46). Obviously, the PCR approach detected the BoNt-C1 gene fragment in some of the samples where no toxin expression has occurred. Thus it is suggested that the qualitative immunostick-ELISA represents a potential in vitro alternative to the mouse-bioassay for assessing the BoNt-C1 production potential in environmental samples. In contrast, qualitative BoNt-C1 gene fragment detection via PCR led to an overestimation of the actual toxin production potential.

  11. A Medical Research and Evaluation Facility (MREF) and Studies Supporting the Medical Chemical Defense Program: Task 95-39: Methods Development and Validation of Two Mouse Bioassays for Use in Quantifying Botulinum Toxins (A, B, C, D and E) and Toxin Antibody Titers

    National Research Council Canada - National Science Library

    Olson, Carl

    1997-01-01

    Ths task was conducted for the U.S. Army Medical Materiel Development Activity (USAMMDA) to validate two mouse bioassays for quantify botulinum toxin potency and neutralizing antibodies to botulimun toxins...

  12. A rapid bioassay for detecting saxitoxins using a Daphnia acute toxicity test.

    Science.gov (United States)

    Ferrão-Filho, Aloysio da S; Soares, Maria Carolina S; de Magalhães, Valéria Freitas; Azevedo, Sandra M F O

    2010-06-01

    Bioassays using Daphnia pulex and Moina micrura were designed to detect cyanobacterial neurotoxins in raw water samples. Phytoplankton and cyanotoxins from seston were analyzed during 15 months in a eutrophic reservoir. Effective time to immobilize 50% of the exposed individuals (ET50) was adopted as the endpoint. Paralysis of swimming movements was observed between approximately 0.5-3 h of exposure to lake water containing toxic cyanobacteria, followed by an almost complete recovery of the swimming activity within 24 h after being placed in control water. The same effects were observed in bioassays with a saxitoxin-producer strain of Cylindrospermopsis raciborskii isolated from the reservoir. Regression analysis showed significant relationships between ET50 vs. cell density, biomass and saxitoxins content, suggesting that the paralysis of Daphnia in lake water samples was caused by saxitoxins found in C. raciborskii. Daphnia bioassay was found to be a sensitive method for detecting fast-acting neurotoxins in natural samples, with important advantages over mouse bioassays. Copyright 2010 Elsevier Ltd. All rights reserved.

  13. Bioassay guideline 1: general guidlines for bioassay programs

    International Nuclear Information System (INIS)

    1980-01-01

    This guideline is the first of a series of documents which elaborate criteria for bioassay programs, to be presented as recommendations to the Atomic Energy Control Board. It specifies which workers require routine bioassays, the accuracy and frequency of measurements, the dose levels at which specific actions must be taken, and the documentation required

  14. Comparison of mouse and swine bioassays for determination of soil arsenic relative bioavailability

    Science.gov (United States)

    Evaluation of soil arsenic (As) relative bioavailability (RBA) is essential to accurately assess human exposure to As contaminated soils via the incidental ingestion pathway. A variety of animal bioassays have been developed to estimate As RBA in contaminated soils and dusts, wit...

  15. Body weight considerations in the B6C3F1 mouse and the use of dietary control to standardize background tumor incidence in chronic bioassays

    International Nuclear Information System (INIS)

    Leakey, Julian E.A.; Seng, John E.; Allaben, William T.

    2003-01-01

    In B6C3F 1 mice, the rate of body growth influences susceptibility to liver neoplasia and large variations in body weight can complicate the interpretation of bioassay data. The relationship between body weight and liver tumor incidence was calculated for historical control populations of male and female ad libitum-fed mice (approx. 2750 and 2300 animals, respectively) and in populations of male and female mice which had been subjected to forced body weight reduction due to either dietary restriction or exposure to noncarcinogenic chemicals (approx. 1600 and 1700, respectively). Resulting tumor risk data were then used to construct idealized weight curves for male and female B6C3F 1 mice; these curves predict a terminal background liver tumor incidence of 15-20%. Use of dietary control to manipulate body growth of male B6C3F 1 mice to fit the idealized weight curve was evaluated in a 2-year bioassay of chloral hydrate. Cohorts of mice were successfully maintained at weights approximating their idealized target weights throughout the study. These mice exhibited less body weight variation than their ad libitum-fed counterparts (e.g., standard deviations of body weight were 1.4 and 3.4 g for respective control groups at 36 weeks). Historical control body weight and tumor risk data from the two male mouse populations were utilized to predict background liver tumor rates for each experimental group of the chloral hydrate study. The predicted background tumor rates closely matched the observed rates for both the dietary controlled and ad libitum-fed chloral hydrate control groups when each mouse was evaluated according to either its weekly food consumption or its weekly change in body weight

  16. Formation of DNA adducts in mouse tissues after 1-nitropyrene administration

    International Nuclear Information System (INIS)

    Mitchell, C.E.

    1986-01-01

    DNA adducts were isolated and characterized in mouse lung, liver and kidney after intratracheal instillation of [ 3 H]-1-nitropyrene (1-NP). HPLC analysis of the enzymatically digested DNA indicated the presence of multiple DNA adducts in mouse lung, liver and kidney. These results indicate that DNA adducts of 1-NP are formed in mouse lung, liver and kidney after intratracheal instillation of 1-NP; the HPLC profiles of the multiple adducts suggests that adducts may be formed via metabolic pathways that involve both nitroreduction and ring-oxidation. 6 references, 1 figure

  17. Characterization of estrogen and androgen activity of food contact materials by different in vitro bioassays (YES, YAS, ERα and AR CALUX and chromatographic analysis (GC-MS, HPLC-MS.

    Directory of Open Access Journals (Sweden)

    Johannes Mertl

    Full Text Available Endocrine active substances (EAS show structural similarities to natural hormones and are suspected to affect the human endocrine system by inducing hormone dependent effects. Recent studies with in vitro tests suggest that EAS can leach from packaging into food and may therefore pose a risk to human health. Sample migrates from food contact materials were tested for estrogen and androgen agonists and antagonists with different commonly used in vitro tests. Additionally, chemical trace analysis by GC-MS and HPLC-MS was used to identify potential hormone active substances in sample migrates. A GC-MS method to screen migrates for 29 known or potential endocrine active substances was established and validated. Samples were migrated according to EC 10/2011, concentrated by solid phase extraction and tested with estrogen and androgen responsive reporter gene assays based on yeast cells (YES and YAS or human osteoblast cells (ERα and AR CALUX. A high level of agreement between the different bioassays could be observed by screening for estrogen agonists. Four out of 18 samples tested showed an estrogen activity in a similar range in both, YES and ERα CALUX. Two more samples tested positive in ERα CALUX due to the lower limits of detection in this assay. Androgen agonists could not be detected in any of the tested samples, neither with YAS nor with AR CALUX. When testing for antagonists, significant differences between yeast and human cell-based bioassays were noticed. Using YES and YAS many samples showed a strong antagonistic activity which was not observed using human cell-based CALUX assays. By GC-MS, some known or supposed EAS were identified in sample migrates that showed a biological activity in the in vitro tests. However, no firm conclusions about the sources of the observed hormone activity could be obtained from the chemical results.

  18. Coupling of In Vitro Bioassays with Planar Chromatography in Effect-Directed Analysis.

    Science.gov (United States)

    Weiss, Stefan C; Egetenmeyer, Nicole; Schulz, Wolfgang

    Modern analytical test methods increasingly detect anthropogenic organic substances and their transformation products in water samples and in the environment. The presence of these compounds might pose a risk to the aquatic environment. To determine a possible (eco)toxicological risk, aquatic samples are tested using various bioassays, including sub-organismic assays such as the luminescent bacteria inhibition test, the acetylcholinesterase inhibition test, and the umu-test. The effect-directed analysis (EDA) combines physicochemical separation methods with biological (in vitro) tests. High-performance thin-layer chromatography (HPTLC) has proved to be particularly well suited for the separation of organic compounds and the subsequent analysis of effects by the application of the biotests directly on the surface of the HPTLC plate. The advantage of using HPTLC in comparison to high-performance liquid chromatography (HPLC) for EDA is that the solvent which is used as a mobile phase during chromatography is completely evaporated after the separation and therefore can no longer influence the applied bioassays.A prioritization during the complex identification process can be achieved when observed effects are associated with the separated zones in HPTLC. This increases the probability of identifying the substance responsible for an adverse effect from the multitude of organic trace substances in environmental samples. Furthermore, by comparing the pattern of biological effects of a separated sample, it is possible to track and assess changes in biological activity over time, over space, or in the course of a process, even without identifying the substance. HPTLC has already been coupled with various bioassays.Because HPTLC is a very flexible system, various detection techniques can be used and combined. In addition to the UV/Vis absorption and fluorescence measurements, TLC can also be coupled with a mass spectrometer (MS) for compound identification. In addition

  19. Mouse bioassay to assess oestrogenic and anti-oestrogenic compounds: Hydroxytamoxifen, Diethylstilbestrol and Genistein

    Czech Academy of Sciences Publication Activity Database

    Köhlerová, Eva; Škarda, Josef

    2004-01-01

    Roč. 51, č. 5 (2004), s. 209-217 ISSN 0931-184X R&D Projects: GA ČR GA524/02/0406; GA AV ČR IBS5045302; GA AV ČR KSK5020115 Institutional research plan: CEZ:AV0Z5045916 Keywords : bioassay * anti-oestrogens * oestrogenicity Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition Impact factor: 0.471, year: 2004

  20. Bio-assay guided isolation of α-glucosidase inhibitory constituents from Hibiscus mutabilis leaves.

    Science.gov (United States)

    Kumar, Deepak; Kumar, Hemanth; Vedasiromoni, J R; Pal, Bikas C

    2012-01-01

    The increasing demand for natural-product-based medicines and health-care products for the management of diabetes encouraged investigation of this commonly available Indian plant. To establish the anti-diabetic (α-glucosidase inhibitory) activity of H. mutabilis leaf extract, isolate and identify the constituents responsible for the activity, and validate a HPLC method for quantification of the active constituents for standardisation of the extract. The methanolic extract of leaves was partitioned between water, n-butanol and ethyl acetate. Bio-assay guided fractionation, based on inhibition of α-glucosidase, allowed isolation and identification of the active components. The active components were quantified using RP-HPLC-DAD validated for linearity, limit of detection, limit of quantification, precision, accuracy and robustness for this plant extract and the partitioned fractions. Ferulic acid and caffeic acid were identified as the α-glucosidase inhibitors present in H. mutabilis. They were partitioned into an ethyl acetate fraction. The HPLC-DAD calibration curve showed good linearity (r² > 0.99). For the recovery studies the %RSD was less than 2%. The interday and intraday variations were found to be less than 4% RSD for retention time and response. The identification of α-glucosidase inhibition activity in H. mutabilis supports further investigations into the possible use of the plant for the management of diabetes. The HPLC method validated for these extracts will be useful in future research with the plant. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Antiplasmodial Properties and Bioassay-Guided Fractionation of Ethyl Acetate Extracts from Carica papaya Leaves

    Science.gov (United States)

    Melariri, Paula; Campbell, William; Etusim, Paschal; Smith, Peter

    2011-01-01

    We investigated the antiplasmodial properties of crude extracts from Carica papaya leaves to trace the activity through bioassay-guided fractionation. The greatest antiplasmodial activity was observed in the ethyl acetate crude extract. C. papaya showed a high selectivity for P. falciparum against CHO cells with a selectivity index of 249.25 and 185.37 in the chloroquine-sensitive D10 and chloroquine-resistant DD2 strains, respectively. Carica papaya ethyl acetate extract was subjected to bioassay-guided fractionation to ascertain the most active fraction, which was purified and identified using high-pressure liquid chromatography (HPLC) and GC-MS (Gas chromatography-Mass spectrometry) methods. Linoleic and linolenic acids identified from the ethyl acetate fraction showed IC50 of 6.88 μg/ml and 3.58 μg/ml, respectively. The study demonstrated greater antiplasmodial activity of the crude ethyl acetate extract of Carica papaya leaves with an IC50 of 2.96 ± 0.14 μg/ml when compared to the activity of the fractions and isolated compounds. PMID:22174990

  2. Determination of Two Sulfonylurea Herbicides Residues in Soil Environment Using HPLC and Phytotoxicity of These Herbicides by Lentil Bioassay.

    Science.gov (United States)

    Mehdizadeh, Mohammad; Alebrahim, Mohammad Taghi; Roushani, Mahmoud

    2017-07-01

    A HPLC-UV detection system was used for determination of sulfosulfuron and tribenuron methyl residues from soils. The soils were fortified with sulfosulfuron and tribenuron methyl at rates of 26 and 15 g a.i. ha -1 respectively and samples were taken randomly on 0 (2 h), 1, 2, 4, 10, 20, 40, 60, 90 and 120 days after treatment. The final extracts were prepared for analysis by HPLC. The results showed that degradation of both herbicides in the silty loam soil was faster than sandy loam soil. Half-life of sulfosulfuron was ranged from 5.37 to 10.82 days however this value for tribenuron methyl was ranged from 3.23 to 5.72 days on different soils. The residue of both herbicides at 120 days after application in wheat field had no toxicitic effect on lentil. It was concluded that HPLC analysis procedure was an appropriate method for determination of these herbicides from soils.

  3. Rapid bioassay for oil-contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Ashworth, J. [ALS Environmental, Edmonton, AB (Canada); Oosterbroek, L. [HydroQual, Calgary, AB (Canada)

    2010-07-01

    This PowerPoint presentation described a study conducted to develop a rapid bioassay for soils contaminated with oil. The bioassay method was designed for a weight of evidence (WoE) approach and eco-contact guideline derivation protocol. Microtox bioassays were conducted on cyclodextrin extracts of soil quantified by solvent extraction and gas chromatography. The method was demonstrated using straight {beta}-cyclodextrin soil extracts and activated {beta}-cyclodextrin soil extracts. An analysis of the methods showed that the activation step weakens or breaks the cyclodextrin and polycyclic hydrocarbon (PHC) inclusion complex. The released PHC became toxic to the microtox organism. Results from the bioassays were then correlated with earthworm reproduction bioassay results. tabs., figs.

  4. Detection of Toxoplasma gondii by PCR and mouse bioassay in commercial cuts of pork from experimentally infected pigs Detecção do Toxoplasma gondii por PCR e bioensaio em camundongo em cortes comerciais de carnes de suínos infectados experimentalmente

    Directory of Open Access Journals (Sweden)

    V.S. Tsutsui

    2007-02-01

    Full Text Available The distribution of T. gondii in commercial cuts of pork (ham, tenderloin, spareribs and arm picnic by PCR and bioassay from experimentally infected pigs, was evaluated. Eighteen mixed breed pigs were divided into two groups (G. The G1 animals (n=10 were infected with 4 x10(4 oocysts of the T. gondii VEG strain and the G2 animals (n=8 were used as control. Pigs of both groups were slaughtered at 59th day after infection, and meat samples were collected for bioassay and PCR. All animals from G1 were positive by at least one or both tests, and all control animals were negative. T. gondii was identified in pork by mouse bioassay and PCR in 27/40 (67.5% and in 9/40 (22.5% of the evaluated samples, respectively. There were no statistical differences in the distribution of tissue cysts from commercial cuts of pork by bioassay (P>0.05. However, statistical differences were observed when mouse bioassay and PCR were compared (PAvaliou-se a presença de T. gondii em cortes comerciais de carne suína (pernil, lombo, costela e paleta, por meio do bioensaio e PCR, em animais experimentalmente inoculados. Dois grupos (G foram formados. Os animais do G1 (n=10 foram inoculados com 4 x10(4 oocistos da cepa VEG e os do G2 (n=8 permaneceram como grupo-controle, não inoculado. Todos os animais foram abatidos no dia 59 após a infecção, quando foram colhidas as amostras de carne para a realização das provas de bioensaio e da PCR. Todos os suínos do G1 apresentaram-se positivos a pelo menos um dos testes de diagnóstico ou a ambos, e os do grupo-controle permaneceram negativos. Não houve diferenças significativas em relação aos tipos de cortes comerciais e à presença do parasita no bioensaio (P>0,05. O bioensaio foi capaz de detectar T. gondii em 27/40 (67,5% amostras e a PCR em 9/40 (22,5%. O estudo mostrou diferença entre o bioensaio e a PCR (P<0,01.

  5. Solid-phase extraction clean-up of ciguatoxin-contaminated coral fish extracts for use in the mouse bioassay.

    Science.gov (United States)

    Wong, Chun Kwan; Hung, Patricia; Lee, Kellie L H; Kam, Kai Man

    2009-02-01

    Florisil solid-phase extraction (SPE) cartridges were used for purifying ciguatoxin (CTX)-contaminated coral fish extracts, with the aim of removing extracted lipid but retaining optimal level of CTXs in the purified fractions. The CTX-containing fraction (target fraction) in fish ether extract was isolated and purified by eluting through a commercially available Florisil cartridge with hexane-acetone-methanol solvent mixtures of increasing polarity (hexane-acetone (4:1, v/v) < acetone-methanol (7:3, v/v) < 100% methanol). Application of Florisil SPE using acetone-methanol (7:3, v/v) condition facilitated the separation of 4.2 +/- 0.4 mg (mean +/- standard error of the mean (SEM)) of purified target fraction from 20 mg ether extract with good retention of CTXs. The mouse bioassay was used to demonstrate that the average CTX recovery of the target fraction from CTX-spiked samples was 75.8% +/- 3.3%, which was significantly increased by 96.7% +/- 15% when compared with CTX recovery from ether extracts (44.8% +/- 5.2%) without performing SPE purification. Over 70% of non-target lipids were removed in which no CTX toxicity was found. Moreover, the target fractions of both CTX-spiked and naturally CTX-contaminated samples gave more prominent toxic responses of hypothermia and/or induced more rapid death of the mice. The use of acetone-methanol (7:3, v/v) condition in the elution could significantly improve overall recovery of CTXs, while minimizing the possible interferences of lipid matrix from co-extractants on mice.

  6. A comparative study for PSP toxins quantification by using MBA and HPLC official methods in shellfish.

    Science.gov (United States)

    Ben-Gigirey, B; Rodríguez-Velasco, M L; Otero, A; Vieites, J M; Cabado, A G

    2012-10-01

    Commission Regulation (EC) N° 2074/2005 recognises the biological method as the reference method for Paralytic Shellfish Poisoning (PSP) toxins detection in molluscs. It was amended by Commission Regulation (EC) N° 1664/2006 that accepted the so-called Lawrence method as an alternative to the reference method. The goal of this study was to compare AOAC Official Methods of Analysis 959.08 (Biological method) and 2005.06 (Prechromatographic Oxidation and Liquid Chromatography with fluorescence detection) in samples with different toxin profiles. The influence of extraction solvent in the total samples toxicity was also evaluated. A total of 40 samples including mussels, clams, scallops, razor-clams, cockles, oysters and barnacles were analysed by both official methods. Samples were selected with Alexandrium and Gymnodinium toxic profiles, from different origin and including several presentations: fresh, frozen, canned and boiled. Acetic and hydrochloric acid extractions were performed in all samples and the extracts were simultaneously analysed by both methods. Most samples were naturally contaminated and two samples were spiked. Comparison of both official methods, mouse bioassay (MBA) with HCl extraction and Liquid Chromatography with fluorescence detection (HPLC-FLD) with acetic acid extraction, led to an 85% of consistent results regarding compliance with legal limit, including samples below and above it. The linear correlation coefficient was r² = 0.69 and the paired t test (two tails, α = 0.05) indicated that there were not significant differences among both sets of data. Nevertheless, toxicity differences were found in several samples. In 15 out of 18 shellfish with a Gymnodinium toxic profile, higher toxicity levels were obtained by MBA. This fact was more evident in 7 samples, partially related to the lack of standards and the impossibility of analysing dc-NEO, C1, 2 and GTX6 at the beginning of the study. However, other factors concerning the extraction

  7. Bioassay Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Bioassay Laboratory is an accredited laboratory capable of conducting standardized and innovative environmental testing in the area of aquatic ecotoxicology. The...

  8. Edible seaweed as future functional food: Identification of α-glucosidase inhibitors by combined use of high-resolution α-glucosidase inhibition profiling and HPLC-HRMS-SPE-NMR.

    Science.gov (United States)

    Liu, Bingrui; Kongstad, Kenneth T; Wiese, Stefanie; Jäger, Anna K; Staerk, Dan

    2016-07-15

    Crude chloroform, ethanol and acetone extracts of nineteen seaweed species were screened for their antioxidant and α-glucosidase inhibitory activity. Samples showing more than 60% α-glucosidase inhibitory activity, at a concentration of 1 mg/ml, were furthermore investigated using high-resolution α-glucosidase inhibition profiling combined with high-performance liquid chromatography-high-resolution mass spectrometry-solid-phase extraction-nuclear magnetic resonance spectroscopy (HR-bioassay/HPLC-HRMS-SPE-NMR). The results showed Ascophyllum nodosum and Fucus vesicolosus to be rich in antioxidants, equaling a Trolox equivalent antioxidant capacity of 135 and 108 mM Troloxmg(-1) extract, respectively. HR-bioassay/HPLC-HRMS-SPE-NMR showed the α-glucosidase inhibitory activity of A. nodosum, F. vesoculosus, Laminaria digitata, Laminaria japonica and Undaria pinnatifida to be caused by phlorotannins as well as fatty acids - with oleic acid, linoleic acid and eicosapentaenoic acid being the most potent with IC50 values of 0.069, 0.075 and 0.10 mM, respectively, and showing a mixed-type inhibition mode. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. 77 FR 14837 - Bioassay at Uranium Mills

    Science.gov (United States)

    2012-03-13

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0057] Bioassay at Uranium Mills AGENCY: Nuclear Regulatory..., ``Bioassay at Uranium Mills.'' This guide describes a bioassay program acceptable to the NRC staff for uranium mills and applicable portions of uranium conversion facilities where the possibility of exposure...

  10. Bioassay criteria for environmental restoration workers

    International Nuclear Information System (INIS)

    Carbaugh, E.H.; Bihl, D.E.

    1993-01-01

    Environmental restoration (ER) work at the U. S. Department of Energy Hanford Site posed questions concerning when to perform bioassay monitoring of workers for potential intakes of radioactivity. Application of criteria originally developed for use inside radionuclide processing facilities to ER work resulted in overly restrictive bioassay requirements. ER work typically involves site characterization or, excavating large quantities of potentially contaminated soil, rather than working with concentrated quantities of radioactivity as in a processing facility. An improved approach, tailored to ER work, provided soil contamination concentrations above which worker bioassay would be required. Soil concentrations were derived assuming acute or chronic intakes of 2% of an Annual Limit on Intake (ALI), or a potential committed effective dose equivalent of 100 mrem, and conservative dust loading of air from the work. When planning ER work, the anticipated soil concentration and corresponding need for bioassay could be estimated from work-site historical records. Once site work commenced, soil sampling and work-place surveys could be used to determine bioassay needs. This approach substantially reduced the required number of bioassay samples with corresponding reductions in analytical costs, schedules, and more flexible work-force management. (Work supported by the US Department of Energy under contract DOE-AC06-76RLO 1830.)

  11. Bioassay programs for radiation protection

    International Nuclear Information System (INIS)

    1979-01-01

    This report discusses the rationale for the establishment of bioassay programs as a means of protection for radiation workers in the nuclear industry. The bioassay program of the Radiation Protection Bureau is described for the years 1966-1978 and plans for future changes are outlined. (auth)

  12. Investigation of independence in inter-animal tumor-type occurrences within the NTP rodent-bioassay database

    Energy Technology Data Exchange (ETDEWEB)

    Bogen, K.T. [Lawrence Livermore National Lab., CA (United States); Seilkop, S. [Analytical Sciences, Inc., Durham, NC (United States)

    1993-05-01

    Statistically significant elevation in tumor incidence at multiple histologically distinct sites is occasionally observed among rodent bioassays of chemically induced carcinogenesis. If such data are to be relied on (as they have, e.g., by the US EPA) for quantitative cancer potency assessment, their proper analysis requires a knowledge of the extent to which multiple tumor-type occurrences are independent or uncorrelated within individual bioassay animals. Although difficult to assess in a statistically rigorous fashion, a few significant associations among tumor-type occurrences in rodent bioassays have been reported. However, no comprehensive studies of animal-specific tumor-type occurrences at death or sacrifice have been conducted using the extensive set of available NTP rodent-bioassay data, on which most cancer-potency assessment for environmental chemicals is currently based. This report presents the results of such an analysis conducted on behalf of the National Research Council`s Committee on Risk Assessment for Hazardous Air Pollutants. Tumor-type associations among individual animals were examined for {approximately}2500 to 3000 control and {approximately}200 to 600 treated animals using pathology data from 62 B6C3F1 mouse studies and 61 F/344N rat studies obtained from a readily available subset of the NTP carcinogenesis bioassay database. No evidence was found for any large correlation in either the onset probability or the prevalence-at-death or sacrifice of any tumor-type pair investigated in control and treated rats and niece, although a few of the small correlations present were statistically significant. Tumor-type occurrences were in most cases nearly independent, and departures from independence, where they did occur, were small. This finding is qualified in that tumor-type onset correlations were measured only indirectly, given the limited nature of the data analyzed.

  13. Development of On-Line High Performance Liquid Chromatography (HPLC)-Biochemical Detection Methods as Tools in the Identification of Bioactives

    Science.gov (United States)

    Malherbe, Christiaan J.; de Beer, Dalene; Joubert, Elizabeth

    2012-01-01

    Biochemical detection (BCD) methods are commonly used to screen plant extracts for specific biological activities in batch assays. Traditionally, bioactives in the most active extracts were identified through time-consuming bio-assay guided fractionation until single active compounds could be isolated. Not only are isolation procedures often tedious, but they could also lead to artifact formation. On-line coupling of BCD assays to high performance liquid chromatography (HPLC) is gaining ground as a high resolution screening technique to overcome problems associated with pre-isolation by measuring the effects of compounds post-column directly after separation. To date, several on-line HPLC-BCD assays, applied to whole plant extracts and mixtures, have been published. In this review the focus will fall on enzyme-based, receptor-based and antioxidant assays. PMID:22489144

  14. Bioassay guideline 2: guidelines for tritium bioassay

    International Nuclear Information System (INIS)

    1983-01-01

    This guideline is one of a series under preparation by the Federal-Provincial Working Group on Bioassay and In Vivo Monitoring Criteria. In this report tritium compounds have been grouped into four categories for the purpose of calculating Annual Limits on Intake and Investigation Levels: tritium gas, tritiated water, tritium-labelled compounds and nucleic acid precursors

  15. Bioassay method for Uranium in urine by Delay Neutron counting; Metoda Bioassay Uranium dalam urin dengan pencacahan Netron Kasip

    Energy Technology Data Exchange (ETDEWEB)

    Suratman,; Purwanto,; Sukarman-Aminjoyo, [Yogyakarta Nuclear Research Centre, National Atomic Energy Agency, Yogyakarta (Indonesia)

    1996-04-15

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 {mu}g.

  16. Circular Bioassay Platforms for Applications in Microwave-Accelerated Techniques.

    Science.gov (United States)

    Mohammed, Muzaffer; Clement, Travis C; Aslan, Kadir

    2014-12-02

    In this paper, we present the design of four different circular bioassay platforms, which are suitable for homogeneous microwave heating, using theoretical calculations (i.e., COMSOL™ multiphysics software). Circular bioassay platforms are constructed from poly(methyl methacrylate) (PMMA) for optical transparency between 400-800 nm, has multiple sample capacity (12, 16, 19 and 21 wells) and modified with silver nanoparticle films (SNFs) to be used in microwave-accelerated bioassays (MABs). In addition, a small monomode microwave cavity, which can be operated with an external microwave generator (100 W), for use with the bioassay platforms in MABs is also developed. Our design parameters for the circular bioassay platforms and monomode microwave cavity during microwave heating were: (i) temperature profiles, (ii) electric field distributions, (iii) location of the circular bioassay platforms inside the microwave cavity, and (iv) design and number of wells on the circular bioassay platforms. We have also carried out additional simulations to assess the use of circular bioassay platforms in a conventional kitchen microwave oven (e.g., 900 W). Our results show that the location of the circular bioassay platforms in the microwave cavity was predicted to have a significant effect on the homogeneous heating of these platforms. The 21-well circular bioassay platform design in our monomode microwave cavity was predicted to offer a homogeneous heating pattern, where inter-well temperature was observed to be in between 23.72-24.13°C and intra-well temperature difference was less than 0.21°C for 60 seconds of microwave heating, which was also verified experimentally.

  17. A cytocidal tissue kallikrein isolated from mouse submandibular glands.

    Science.gov (United States)

    Murakami, K; Ikigai, H; Nagumo, N; Tomita, M; Shimamura, T

    1989-11-06

    A cytocidal factor against mouse thymocytes was purified from the submandibular glands of female BALB/c mice using Sephadex G-50 gel filtration chromatography and reverse-phase HPLC. SDS-PAGE and amino acid sequence analysis revealed that the cytocidal factor was mouse glandular kallikrein (mGK)-6. mGK-6 showed an optimal enzyme activity at pH 10 and a cytocidal activity against thymocytes in a dose-dependent manner.

  18. [Investigation on pattern and methods of quality control for Chinese materia medica based on dao-di herbs and bioassay - bioassay for Coptis chinensis].

    Science.gov (United States)

    Yan, Dan; Xiao, Xiao-he

    2011-05-01

    Establishment of bioassay methods is the technical issues to be faced with in the bioassay of Chinese materia medica. Taking the bioassay of Coptis chinensis Franch. as an example, the establishment process and application of the bioassay methods (including bio-potency and bio-activity fingerprint) were explained from the aspects of methodology, principle of selection, experimental design, method confirmation and data analysis. The common technologies were extracted and formed with the above aspects, so as to provide technical support for constructing pattern and method of the quality control for Chinese materia medica based on the dao-di herbs and bioassay.

  19. Radioimmunoassay of paralytic shellfish toxins in clams and mussels

    International Nuclear Information System (INIS)

    Yang, G.C.; Imagire, S.J.; Yasaei, P.; Ragelis, E.P.; Park, D.L.; Page, S.W.; Carlson, R.E.; Guire, P.E.

    1987-01-01

    Shellfish contaminated with paralytic shellfish poisons (PSP) compromise human health. The threat of this contamination results in enormous economic losses in the recreational and commercial exploitation of shellfish resources in the affected areas. Most states deal with the PSP problem either by prohibiting the collection of shellfish during certain time periods or by instituting monitoring programs. The only recognized method of analysis for PSP that is currently and routinely used in monitoring programs is the time-of-death mouse bioassay. Several attempts to develop simple and highly specific biochemical assays for the detection and quantitation of the PSP toxins have been reported. More recently, much improved immunoassays have been developed. To evaluate the validity and usefulness of the immunoassay for the determination of PSP toxins, the authors have used extracts of shellfish gathered from Maine and Connecticut to compare the results of the mouse bioassay and HPLC methods with the radioimmunoassay developed previously

  20. Rapid bioassay-guided screening of toxic substances in vegetable oils that shorten the life of SHRSP rats

    Directory of Open Access Journals (Sweden)

    Lewandowski Paul

    2010-02-01

    Full Text Available Abstract It has been consistently reported that vegetable oils including canola oil have a life shortening effect in Stroke-Prone Spontaneously Hypertensive Rats (SHRSP and this toxic effect is not due to the fatty acid composition of the oil. Although it is possible that the phytosterol content or type of phytosterol present in vegetable oils may play some role in the life shortening effect observed in SHRSP rats this is still not completely resolved. Furthermore supercritical CO2 fractionation of canola oil with subsequent testing in SHRSP rats identified safe and toxic fractions however, the compounds responsible for life shortening effect were not characterised. The conventional approach to screen toxic substances in oils using rats takes more than six months and involves large number of animals. In this article we describe how rapid bioassay-guided screening could be used to identify toxic substances derived from vegetable oils and/or processed foods fortified with vegetable oils. The technique incorporates sequential fractionation of oils/processed foods and subsequent treatment of human cell lines that can be used in place of animal studies to determine cytotoxicity of the fractions with structural elucidation of compounds of interest determined via HPLC-MS and GC-MS. The rapid bioassay-guided screening proposed would require two weeks to test multiple fractions from oils, compared with six months if animal experiments were used to screen toxic effects. Fractionation of oil before bio-assay enhances the effectiveness of the detection of active compounds as fractionation increases the relative concentration of minor components.

  1. Studies on Erythropoietin Bioassay Method

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kyoung Sam; Ro, Heung Kyu; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1975-09-15

    It is the purpose of this paper to design the most preferable method of erythropoietin bioassay in Korea. Bioassay utilizing polycythemic mice are currently in general use for the indirect determination of erythropoietin. Assay animals are usually prepared either by transfusion or by exposure to reduced oxygen tension in specially constructed chamber. We prepared the polycythemic mice by the specially constructed hypobaric chamber. We observed weights and hematocrits of the mice in the hypobaric chamber, then hematocrits and 72 hours {sup 59}Fe red cell uptake ratio of the polycythemic mice induced by hypoxia after removal from the hypobaric chamber. We designed the method of erythropoietin bioassay according to the results obtained by above experiments. Then we measured the 72 hours {sup 59}Fe red cell uptake ratio of the polycythemic mice with normal saline, normal plasma and anemic plasma according to the method we designed. The results are followed:1) The hematocrits of the mice in hypobaric chamber increased to 74% in 11 days. It is preferable to maintain the pressure of the chamber to 400 mmHg for first 4 days then 300 mmHg for last 10 days to reduce the death rate and time consuming in hypobaric chamber. 2) After removal from the hypobaric chamber, the 72 hours {sup 59}Fe red cell uptake ratio decreased rapidly and maintained the lowest level from the fourth day to tenth day. 3) We design the method of erythropoietin bioassay according to the results of above experiment and to the half life of erythropoietin. 4) The Korean product {sup 59}Fe is mixture of {sup 55}Fe and {sup 59}Fe. And the {sup 59}Fe red cell uptake ratio in normal mice was far less with Korean product {sup 59}Fe than with pure {sup 59}Fe of foreign product. So it is desirable to use pure {sup 59}Fe in this method of erythropoietin bioassay. 5) Considering the cost, the technique, the time consuming and the sensitivity it is the most preferable method of erythropoietin bioassay in Korea

  2. Effect of Associated Bacteria on the Growth and Toxicity of Alexandrium catenella

    Science.gov (United States)

    Uribe, Paulina; Espejo, Romilio T.

    2003-01-01

    Saprophytic bacteria in cultures of the marine dinoflagellate Alexandrium catenella were removed to assess their effect on growth and paralytic shellfish poisoning toxin production of this dinoflagellate. The actual axenic status was demonstrated by the lack of observable bacteria both immediately after treatment and following extended incubation in the absence of antibiotics. Bacteria were measured by counting CFU and also by epifluorescence microscopy and PCR amplification of bacterial 16S-23S spacer ribosomal DNA to detect noncultivable bacteria. Removal of bacteria did not have any effect on the growth of the dinoflagellate except for the inhibition of A. catenella disintegration after reaching the stationary phase. Toxicity was determined in dinoflagellate cell extracts by different methods: high-performance liquid chromatography (HPLC); an electrophysiological test called the Electrotest, which measures the inhibition of saxitoxin-sensitive Na+ channels expressed in a cell line; and a mouse bioassay, which measures the toxic effect on the whole mammal neuromuscular system. A lower toxicity of the dinoflagellates in axenic culture was observed by these three methods, though the difference was significant only by the mouse bioassay and HPLC methods. Altogether the results indicate that axenic cultures of A. catenella are able to produce toxin, though the total toxicity is probably diminished to about one-fifth of that in nonaxenic cultures. PMID:12514056

  3. A cytotoxic serine proteinase isolated from mouse submandibular gland.

    Science.gov (United States)

    Shimamura, T; Nagumo, N; Ikigai, H; Murakami, K; Okubo, S; Toda, M; Ohnishi, R; Tomita, M

    1989-08-01

    We have isolated a novel cytotoxic factor from the submandibular glands of male BALB/c mice by Sephadex G-50 gel filtration chromatography and reverse-phase HPLC. The cytotoxic factor is a serine proteinase, which belongs to the mouse glandular kallikrein (mGK) family, with an Mr of approximately 27,000. The purified serine proteinase showed cytotoxic activity against mouse thymocytes in a dose-dependent manner, and a serine proteinase inhibitor, diisopropyl fluorophosphate, blocked its cytotoxic activity.

  4. Rapid Bioassay-Guided Isolation of Antibacterial Clerodane Type Diterpenoid from Dodonaea viscosa (L. Jaeq.

    Directory of Open Access Journals (Sweden)

    Muhammad Khurram

    2015-08-01

    Full Text Available Plant extracts are complex matrices and, although crude extracts are widely in use, purified compounds are pivotal in drug discovery. This study describes the application of automated preparative-HPLC combined with a rapid off-line bacterial bioassay, using reduction of a tetrazolium salt as an indicator of bacterial metabolism. This approach enabled the identification of fractions from Dodonaea viscosa that were active against Staphylococcus aureus and Escherichia coli, which, ultimately, resulted in the identification of a clerodane type diterpenoid, 6β-hydroxy-15,16-epoxy-5β, 8β, 9β, 10α-cleroda-3, 13(16, 14-trien-18-oic acid, showing bacteriostatic activity (minimum inhibitory concentration (MIC = 64–128 µg/mL against test bacteria. To the best of our knowledge, this is the first report on antibacterial activity of this metabolite from D. viscosa.

  5. Third-generation Ah receptor-responsive luciferase reporter plasmids: amplification of dioxin-responsive elements dramatically increases CALUX bioassay sensitivity and responsiveness.

    Science.gov (United States)

    He, Guochun; Tsutsumi, Tomoaki; Zhao, Bin; Baston, David S; Zhao, Jing; Heath-Pagliuso, Sharon; Denison, Michael S

    2011-10-01

    2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD, dioxin) and related dioxin-like chemicals are widespread and persistent environmental contaminants that produce diverse toxic and biological effects through their ability to bind to and activate the Ah receptor (AhR) and AhR-dependent gene expression. The chemically activated luciferase expression (CALUX) system is an AhR-responsive recombinant luciferase reporter gene-based cell bioassay that has been used in combination with chemical extraction and cleanup methods for the relatively rapid and inexpensive detection and relative quantitation of dioxin and dioxin-like chemicals in a wide variety of sample matrices. Although the CALUX bioassay has been validated and used extensively for screening purposes, it has some limitations when screening samples with very low levels of dioxin-like chemicals or when there is only a small amount of sample matrix for analysis. Here, we describe the development of third-generation (G3) CALUX plasmids with increased numbers of dioxin-responsive elements, and stable transfection of these new plasmids into mouse hepatoma (Hepa1c1c7) cells has produced novel amplified G3 CALUX cell bioassays that respond to TCDD with a dramatically increased magnitude of luciferase induction and significantly lower minimal detection limit than existing CALUX-type cell lines. The new G3 CALUX cell lines provide a highly responsive and sensitive bioassay system for the detection and relative quantitation of very low levels of dioxin-like chemicals in sample extracts.

  6. Third-Generation Ah Receptor–Responsive Luciferase Reporter Plasmids: Amplification of Dioxin-Responsive Elements Dramatically Increases CALUX Bioassay Sensitivity and Responsiveness

    Science.gov (United States)

    He, Guochun; Tsutsumi, Tomoaki; Zhao, Bin; Baston, David S.; Zhao, Jing; Heath-Pagliuso, Sharon; Denison, Michael S.

    2011-01-01

    2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD, dioxin) and related dioxin-like chemicals are widespread and persistent environmental contaminants that produce diverse toxic and biological effects through their ability to bind to and activate the Ah receptor (AhR) and AhR-dependent gene expression. The chemically activated luciferase expression (CALUX) system is an AhR-responsive recombinant luciferase reporter gene–based cell bioassay that has been used in combination with chemical extraction and cleanup methods for the relatively rapid and inexpensive detection and relative quantitation of dioxin and dioxin-like chemicals in a wide variety of sample matrices. Although the CALUX bioassay has been validated and used extensively for screening purposes, it has some limitations when screening samples with very low levels of dioxin-like chemicals or when there is only a small amount of sample matrix for analysis. Here, we describe the development of third-generation (G3) CALUX plasmids with increased numbers of dioxin-responsive elements, and stable transfection of these new plasmids into mouse hepatoma (Hepa1c1c7) cells has produced novel amplified G3 CALUX cell bioassays that respond to TCDD with a dramatically increased magnitude of luciferase induction and significantly lower minimal detection limit than existing CALUX-type cell lines. The new G3 CALUX cell lines provide a highly responsive and sensitive bioassay system for the detection and relative quantitation of very low levels of dioxin-like chemicals in sample extracts. PMID:21775728

  7. A specific bioassay for the inhibition of flowering.

    Science.gov (United States)

    Blake, J

    1972-06-01

    A bioassay for the inhibition of flowering involving the in vitro culture of excised, partially-induced, apices of Viscaria candida is described. This bioassay has been used to detect flowering inhibition in extracts from Kalanchoe blossfeldiana.

  8. Bioassay of naturally occurring allelochemicals for phytotoxicity.

    Science.gov (United States)

    Leather, G R; Einhellig, F A

    1988-10-01

    The bioassay has been one of the most widely used tests to demonstrate allelopathic activity. Often, claims that a particular plant species inhibits the growth of another are based entirely on the seed germination response to solvent extracts of the suspected allelopathic plant; few of these tests are of value in demonstrating allelopathy under natural conditions. The veracity of the bioassay for evaluating naturally occurring compounds for phytotoxicity depends upon the physiological and biochemical response capacity of the bioassay organism and the mechanism(s) of action of the allelochemicals. The possibility that more than one allelochemical, acting in concert at very low concentrations, may be responsible for an observed allelopathic effect makes it imperative that bioassays be extremely sensitive to chemical growth perturbation agents. Among the many measures of phytotoxicity of allelochemicals, the inhibition (or stimulation) of seed germination, radicle elongation, and/or seedling growth have been the parameters of choice for most investigations. Few of these assays have been selected with the view towards the possible mechanism of the allelopathic effect.

  9. Herbicide impact on Hormosira banksii gametes measured by fluorescence and germination bioassays

    International Nuclear Information System (INIS)

    Seery, Cliff R.; Gunthorpe, Leanne; Ralph, Peter J.

    2006-01-01

    The innovative bioassay described here involves chlorophyll a fluorescence measurements of gametes from the macroalgae, Hormosira banksii, where gametes (eggs) were exposed to Diuron, Irgarol and Bromacil. Response was assessed as percent inhibition from control of effective quantum yield (ΔF/Fm') of photosystem II, herein referred to as % PSII Inhibition. This was measured with the dual-channelled pulse amplitude modulated (PAM) fluorometer, ToxY-PAM. The fluorescence bioassay was run simultaneously with an established H. banksii germination bioassay to compare sensitivity, precision, and time-to-result. The fluorescence bioassay gave highly sensitive results evidenced by EC 5 s (% PSII Inhibition) for Diuron, Irgarol and Bromacil being three, four and three orders of magnitude (respectively) lower than EC 5 s generated from the germination bioassays. Precision of the fluorescence bioassay was demonstrated with low coefficient of variations (<30%) for all three toxicants. With regard to time, the fluorescence bioassay gave results within 6 h, as opposed to more than 50 h for the germination bioassay. - Chlorophyll a fluorescence measurements form the basis of a macroalgal bioassay with many advantages over germination-based methods

  10. Herbicide impact on Hormosira banksii gametes measured by fluorescence and germination bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Seery, Cliff R. [Institute for Water and Environmental Resource Management, Department of Environmental Sciences, University of Technology, Sydney, Westbourne Street, Gore Hill, 2065 NSW (Australia); Gunthorpe, Leanne [Primary Industries Research Victoria (PIRVic), VIC (Australia); Ralph, Peter J. [Institute for Water and Environmental Resource Management, Department of Environmental Sciences, University of Technology, Sydney, Westbourne Street, Gore Hill, 2065 NSW (Australia)]. E-mail: peter.ralph@uts.edu.au

    2006-03-15

    The innovative bioassay described here involves chlorophyll a fluorescence measurements of gametes from the macroalgae, Hormosira banksii, where gametes (eggs) were exposed to Diuron, Irgarol and Bromacil. Response was assessed as percent inhibition from control of effective quantum yield ({delta}F/Fm') of photosystem II, herein referred to as % PSII Inhibition. This was measured with the dual-channelled pulse amplitude modulated (PAM) fluorometer, ToxY-PAM. The fluorescence bioassay was run simultaneously with an established H. banksii germination bioassay to compare sensitivity, precision, and time-to-result. The fluorescence bioassay gave highly sensitive results evidenced by EC{sub 5}s (% PSII Inhibition) for Diuron, Irgarol and Bromacil being three, four and three orders of magnitude (respectively) lower than EC{sub 5}s generated from the germination bioassays. Precision of the fluorescence bioassay was demonstrated with low coefficient of variations (<30%) for all three toxicants. With regard to time, the fluorescence bioassay gave results within 6 h, as opposed to more than 50 h for the germination bioassay. - Chlorophyll a fluorescence measurements form the basis of a macroalgal bioassay with many advantages over germination-based methods.

  11. Applied in vitro radio bioassay

    International Nuclear Information System (INIS)

    Gaburo, J.C.G.; Sordi, G.M.A.A.

    1992-11-01

    The aim of this publication is to show the concepts and in vitro bioassay techniques as well as experimental procedures related with internal contamination evaluation. The main routes of intake, metabolic behavior, and the possible types of bioassay samples that can be collected for radionuclides analysis are described. Both biological processes and the chemical and physical behavior of the radioactive material of interest are considered and the capabilities of analytical techniques to detect and quantify the radionuclides are discussed. Next, the need of quality assurance throughout procedures are considered and finally a summary of the techniques applied to the internal routine monitoring of IPEN workers is given. (author)

  12. Experimental photoallergic contact dermatitis: a mouse model

    International Nuclear Information System (INIS)

    Maguire, H.C. Jr.; Kaidbey, K.

    1982-01-01

    We have induced photoallergic contact dermatitis in mice to 3,3',4',5 tetrachlorosalicylanilide (TCSA), chlorpromazine and 6-methylcoumarin. These compounds are known to produce photoallergic contact dermatitis in humans. The photoallergic contact dermatitis reaction in the mouse is immunologically specific viz. mice photosensitized to TCSA react, by photochallenge, to that compound and not to chlorpromazine, and conversely. The reaction requires UVA at both sensitization and challenge. It appears to be T-cell mediated in that it can be passively transferred to syngeneic mice by lymph node cells from actively sensitized mice, the histology of the reactions resembles that of classic allergic contact dermatitis in mice, challenge reactions are seen at 24 but not at 4 hr, and photoallergic contact dermatitis can be induced in B-cell deficient mice. The availability of a mouse model for the study of photo-ACD will facilitate the identification of pertinent control mechanisms and may aid in the management of the disease. It is likely that a bioassay for photoallergens of humans can be based on this mouse model

  13. Bioassay method for Uranium in urine by Delay Neutron counting

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Sukarman-Aminjoyo

    1996-01-01

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 μg

  14. Determination of cyanobacteria toxins (microcystins): current situation; Problematica y situacion actual de la determinacion de toxinas de cianobacterias: microcistinas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Navarro, I. M.; Pichardo Sanchez, S.; Carmean Fernandez, A. M. [Universidad de Sevilla (Spain)

    2003-07-01

    A review of the different biological and chemical methods developed to determine cyano bacterial toxins, microcystins (MC), in freshwater has been carried out. However, any of them have been accepted as a standard method by the official environmental agencies. Biological methods as the mouse bioassays, immunoassays or protein phosphatase, inhibition assays are used as screening methods to detect MC. Analytical methods as High Performance Liquid Chromatography (HPLC) or Capillary Electrophoresis (CE), with different detectors, allow to identify and quantify the individual toxins produced by different cyano bacterial species. (Author) 40 refs.

  15. Bioassay Phantoms Using Medical Images and Computer Aided Manufacturing

    International Nuclear Information System (INIS)

    Xu, X. Geroge

    2011-01-01

    A radiation bioassay program relies on a set of standard human phantoms to calibrate and assess radioactivity levels inside a human body for radiation protection and nuclear medicine imaging purposes. However, the methodologies in the development and application of anthropomorphic phantoms, both physical and computational, had mostly remained the same for the past 40 years. We herein propose a 3-year research project to develop medical image-based physical and computational phantoms specifically for radiation bioassay applications involving internally deposited radionuclides. The broad, long-term objective of this research was to set the foundation for a systematic paradigm shift away from the anatomically crude phantoms in existence today to realistic and ultimately individual-specific bioassay methodologies. This long-term objective is expected to impact all areas of radiation bioassay involving nuclear power plants, U.S. DOE laboratories, and nuclear medicine clinics.

  16. Comparison of five bioassay techniques for assessing sediment-bound contaminants

    OpenAIRE

    Ahlf, Wolfgang; Calmano, Wolfgang; Erhard, Judith; Förstner, Ulrich

    1989-01-01

    Biological response could not be predicted based on chemical concentration of the sediment contaminants. Bioassays integrate the response of test organisms to contaminants and nutrients. Comparative results of five acute bioassays indicated that Neubauer phytoassay was the most sensitive. The mircobial biomass and algal growth tests indicated a response to the availability of contaminants and nutrients. These results suggest the usefulness of a diversity of bioassays in toxicity testing of se...

  17. Internal dosimetry performing dose assessments via bioassay measurements

    International Nuclear Information System (INIS)

    Bailey, K.M.

    1993-01-01

    The Internal Dosimetry Department at the Y-12 Plant maintains a state-of-the-art bioassay program managed under the guidance and regulations of the Department of Energy. The two major bioassay techniques currently used at Y-12 are the in vitro (urinalysis) and in vivo (lung counting) programs. Fecal analysis (as part of the in vitro program) is another alternative; however, since both urine and fecal analysis provide essentially the same capabilities for detecting exposures to uranium, the urinalysis is the main choice primarily for aesthetic reasons. The bioassay frequency is based on meeting NCRP 87 objectives which are to monitor the accumulation of radioactive material in exposed individuals, and to ensure that significant depositions are detected

  18. [Quality evaluation of rhubarb dispensing granules based on multi-component simultaneous quantitative analysis and bioassay].

    Science.gov (United States)

    Tan, Peng; Zhang, Hai-Zhu; Zhang, Ding-Kun; Wu, Shan-Na; Niu, Ming; Wang, Jia-Bo; Xiao, Xiao-He

    2017-07-01

    This study attempts to evaluate the quality of Chinese formula granules by combined use of multi-component simultaneous quantitative analysis and bioassay. The rhubarb dispensing granules were used as the model drug for demonstrative study. The ultra-high performance liquid chromatography (UPLC) method was adopted for simultaneously quantitative determination of the 10 anthraquinone derivatives (such as aloe emodin-8-O-β-D-glucoside) in rhubarb dispensing granules; purgative biopotency of different batches of rhubarb dispensing granules was determined based on compound diphenoxylate tablets-induced mouse constipation model; blood activating biopotency of different batches of rhubarb dispensing granules was determined based on in vitro rat antiplatelet aggregation model; SPSS 22.0 statistical software was used for correlation analysis between 10 anthraquinone derivatives and purgative biopotency, blood activating biopotency. The results of multi-components simultaneous quantitative analysisshowed that there was a great difference in chemical characterizationand certain differences inpurgative biopotency and blood activating biopotency among 10 batches of rhubarb dispensing granules. The correlation analysis showed that the intensity of purgative biopotency was significantly correlated with the content of conjugated anthraquinone glycosides (Panalysis and bioassay can achieve objective quantification and more comprehensive reflection on overall quality difference among different batches of rhubarb dispensing granules. Copyright© by the Chinese Pharmaceutical Association.

  19. Collection and control of tritium bioassay samples at Pantex

    International Nuclear Information System (INIS)

    Fairrow, N.L.; Ivie, W.E.

    1992-01-01

    Pantex is the final assembly/disassembly point for US nuclear weapons. The Pantex internal dosimetry section monitors radiation workers once a month for tritium exposure. In order to manage collection and control of the bioassay specimens efficiently, a bar code system for collection of samples was developed and implemented to speed up the process and decrease the number of errors probable when transferring data. In the past, all the bioassay data from samples were entered manually into a computer database. Transferring the bioassay data from the liquid scintillation counter to each individual's dosimetry record required as much as two weeks of concentrated effort

  20. Experimental Studies of quantitative evaluation using HPLC and safety of Bee Venom Acupuncture

    Directory of Open Access Journals (Sweden)

    Seong Bong Jang

    2006-02-01

    Full Text Available Objectives : This study was conducted to carry out quantitative evaluation and safety of Bee Venom Acupuncture. Methods : Content analysis was done using HPLC, measurement of , and histological observations were made on the skin and muscles. Results : 1. According to HPLC analysis, each BVA-1 contained approximately , and BVA-2 contained approximately . But the volume of coating was so minute, slight difference exists between each needle. 2. LD50 of mouse with BVA-1 was 16 counts and this is equivalent to 640 needles/kg, making Bee Venom Acupuncture safe treatment apparatus. 3. Regardless of the number of needles, there was no sign of blood stasis or inflammation detected on the skin and muscle tissues. Conclusion : Above results indicate that the Bee Venom Acupuncture can complement shortcomings of syringe usage as a part of Oriental medicine treatment, but extensive researches should be done for further verification.

  1. Bioassays for risk assessment of coal conversion products

    Energy Technology Data Exchange (ETDEWEB)

    Schacht, S.; Sinder, C.; Pfeifer, F.; Klein, J. [DMT-Gesellschaft fuer Forschung und Pruefung mbH, Essen (Germany)

    1999-07-01

    Traditional as well as biotechnological processing coal leads to complex mixtures of products. Besides chemical and physical characterization, which provides the information for product application, there is a need for bioassays to monitor properties that are probably toxic, mutagenic or cancerogenic. Investigations carried out focused on the selection, adaptation and validation of bioassays for the sensitive estimation of toxic effects. Organisms like bacteria, Daphnia magna and Scenedesmus subspicatus, representing different complexities in the biosphere, were selected as test systems for ecotoxicological and mutagenicity studies. The results obtained indicate that bioassays are, in principle, suitable tools for characterization and evaluation of coal-derived substances and bioconversion products. Using coal products, coal-relevant model compounds and bioconversion products, data for risk assessment are presented. (orig.)

  2. The BIDAS: bioassay data analysis software for evaluating radionuclide intake and dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Lee, Jong Il; Chang, Si Young

    2003-01-01

    The BIDAS (BIoassay Data Analysis Software) computer code was developed for the interpretation of bioassay measurements in terms of the intake and dose using the International Commission on Radiological Protection's(ICRP's) currently recommended respiratory tract, GI-tract and biokinetic models to describe the behavior of the radioactive materials within the body. The code consists of a data base module to the manage bioassay data, a data base module containing the predicted bioassay quantities of each radionuclide, and a computational module to the estimate radionuclide intake and dose from either an acute or a chronic exposure based on the measured bioassay quantities. This paper describes the features of the code as well as the results of the BIDAS validation

  3. Determination of the viability of Toxoplasma gondii in cured ham using bioassay: influence of technological processing and food safety implications.

    Science.gov (United States)

    Bayarri, Susana; Gracia, María J; Lázaro, Regina; Pe Rez-Arquillué, Consuelo; Barberán, Montserrat; Herrera, Antonio

    2010-12-01

    Toxoplasmosis is a zoonotic disease caused by the protozoan Toxoplasma gondii and distributed worldwide. Ingestion of viable cysts from infected raw or undercooked meat is an important route of horizontal transmission of the parasite to humans. Little information is available concerning the effect of commercial curing on cysts of T. gondii. This study is the first in which the influence of processing of cured ham on the viability of T. gondii has been evaluated, using bioassay to assess the risk of infection from eating this meat product. Naturally infected pigs were selected for the study, and a mouse concentration bioassay technique was used to demonstrate viable bradyzoites of T. gondii in porcine tissues and hams. No viable parasites were found in the final product (14 months of curing) based on results of the indirect immunofluorescence assay and histological and PCR analyses. Our results indicate that the consumption of hams cured as described here poses an insignificant risk of acquiring toxoplasmosis. However, additional studies are required to evaluate the safety of ham products cured under different conditions of curing time, salt, and nitrite concentration.

  4. Fluorescence-Based Bioassays for the Detection and Evaluation of Food Materials

    OpenAIRE

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-01-01

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based mi...

  5. Structuring a risk-based bioassay program for uranium usage in university laboratories

    Science.gov (United States)

    Dawson, Johnne Talia

    Bioassay programs are integral in a radiation safety program. They are used as a method of determining whether individuals working with radioactive material have been exposed and have received a resulting dose. For radionuclides that are not found in nature, determining an exposure is straightforward. However, for a naturally occurring radionuclide like uranium, it is not as straightforward to determine whether a dose is the result of an occupational exposure. The purpose of this project is to address this issue within the University of Nevada, Las Vegas's (UNLV) bioassay program. This project consisted of two components that studied the effectiveness of a bioassay program in determining the dose for an acute inhalation of uranium. The first component of the plan addresses the creation of excretion curves, utilizing MATLAB that would allow UNLV to be able to determine at what time an inhalation dose can be attributed to. The excretion curves were based on the ICRP 30 lung model, as well as the Annual Limit Intake (ALI) values located in the Nuclear Regulatory Commission's 10CFR20 which is based on ICRP 30 (International Commission on Radiological Protection). The excretion curves would allow UNLV to be able to conduct in-house investigations of inhalation doses without solely depending on outside investigations and sources. The second component of the project focused on the creation of a risk based bioassay program to be utilized by UNLV that would take into account bioassay frequency that depended on the individual. Determining the risk based bioassay program required the use of baseline variance in order to minimize the investigation of false positives among those individuals who undergo bioassays for uranium work. The proposed program was compared against an evaluation limit of 10 mrem per quarter, an investigational limit of 125 mrem per quarter, and the federal/state requirement of 1.25 rem per quarter. It was determined that a bioassay program whose bioassay

  6. Validation of a Novel Bioassay for Low-level Perchlorate Determination

    Science.gov (United States)

    2014-04-01

    was not attractive, since these reduce PMS2 , and it was thought they would interfere with the stoichiometry of NADH and perchlorate in the bioassay...these reduce PMS2 directly, and would interfere with the stoichiometry of NADH and perchlorate in the bioassay. Thus the only approach that could be

  7. The effect of pesticide residue on caged mosquito bioassays.

    Science.gov (United States)

    Barber, J A S; Greer, Mike; Coughlin, Jamie

    2006-09-01

    Wind tunnel experiments showed that secondary pickup of insecticide residue by mosquitoes in cage bioassays had a significant effect on mortality. Cage bioassays using adult Ochlerotatus taeniorhynchus (Wiedemann) investigated the effect of exposure time to a contaminated surface. Cages were dosed in a wind tunnel using the LC50 for naled (0.124 mg a.i./ml) and an LC25 (0.0772 mg a.i./ml) for naled. Half of the bioassay mosquitoes were moved directly into clean cages with the other half remaining in the sprayed, hence contaminated, cage. Treatment mortality was assessed at 8, 15, 30, 60, 120, 240, and 1,440 min postapplication. Cage contamination had a significant effect on mosquito mortality for both the LC25 and LC50 between 15 and 30 min postapplication.

  8. Integration of laboratory bioassays into the risk-based corrective action process

    International Nuclear Information System (INIS)

    Edwards, D.; Messina, F.; Clark, J.

    1995-01-01

    Recent data generated by the Gas Research Institute (GRI) and others indicate that residual hydrocarbon may be bound/sequestered in soil such that it is unavailable for microbial degradation, and thus possibly not bioavailable to human/ecological receptors. A reduction in bioavailability would directly equate to reduced exposure and, therefore, potentially less-conservative risk-based cleanup soil goals. Laboratory bioassays which measure bioavailability/toxicity can be cost-effectively integrated into the risk-based corrective action process. However, in order to maximize the cost-effective application of bioassays several site-specific parameters should be addressed up front. This paper discusses (1) the evaluation of parameters impacting the application of bioassays to soils contaminated with metals and/or petroleum hydrocarbons and (2) the cost-effective integration of bioassays into a tiered ASTM type framework for risk-based corrective action

  9. Bioassay for aquatic ecosystems review and classification; Rassegna dei principali test di ecotossicologia acquatica

    Energy Technology Data Exchange (ETDEWEB)

    Sanci, Antonella; Rosa, Silvia [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente

    1997-09-01

    Bioassay play a crucial role in assessing the actual or potential impacts of anthropogenic agents on the natural environment. In this technical report, literature on bioassays for aquatic ecosystems has been reviewed and classified. Problems associated with the choice and application of bioassays are discussed.

  10. Comparison of solid and liquid-phase bioassays using ecoscores to assess contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Lors, Christine [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, LGCgE-MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France); Centre National de Recherche sur les Sites et Sols Pollues, 930 Boulevard Lahure, BP 537, 59505 Douai Cedex (France); Ponge, Jean-Francois, E-mail: ponge@mnhn.fr [Museum National d' Histoire Naturelle, Departement Ecologie et Gestion de la Biodiversite, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Martinez Aldaya, Maite [Museum National d' Histoire Naturelle, Departement Ecologie et Gestion de la Biodiversite, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Damidot, Denis [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, LGCgE-MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France)

    2011-10-15

    Bioassays on aqueous and solid phases of contaminated soils were compared, belonging to a wide array of trophic and response levels and using ecoscores for evaluating ecotoxicological and genotoxicological endpoints. The method was applied to four coke factory soils contaminated mainly with PAHs, but also to a lesser extent by heavy metals and cyanides. Aquatic bioassays do not differ from terrestrial bioassays when scaling soils according to toxicity but they are complementary from the viewpoint of ecological relevance. Both aquatic and terrestrial endpoints are strongly correlated with concentrations of 3-ring PAHs. This evaluation procedure allows us to propose a cost-effective battery which embraces a wide array of test organisms and response levels: it includes two rapid bioassays (Microtox) and springtail avoidance), a micronucleus test and three bioassays of a longer duration (algal growth, lettuce germination and springtail reproduction). This battery can be recommended for a cost-effective assessment of polluted/remediated soils. - Highlights: > Comparison of liquid- and solid-phase bioassays on contaminated soils, using ecoscores. > Complementarity of liquid- and solid-phase bioassays for the evaluation of environmental hazards. > Proposal for a restricted battery of 5 most sensitive tests. > Use of this restricted battery for a cost-effective assessment of polluted/remediated soils. - Aqueous and solid phases of contaminated soils give similar results in terms of toxicity but are complementary for the evaluation of environmental hazards by ecoscores.

  11. Soil bioassays as tools for sludge compost quality assessment

    International Nuclear Information System (INIS)

    Domene, Xavier; Sola, Laura; Ramirez, Wilson; Alcaniz, Josep M.; Andres, Pilar

    2011-01-01

    Composting is a waste management technology that is becoming more widespread as a response to the increasing production of sewage sludge and the pressure for its reuse in soil. In this study, different bioassays (plant germination, earthworm survival, biomass and reproduction, and collembolan survival and reproduction) were assessed for their usefulness in the compost quality assessment. Compost samples, from two different composting plants, were taken along the composting process, which were characterized and submitted to bioassays (plant germination and collembolan and earthworm performance). Results from our study indicate that the noxious effects of some of the compost samples observed in bioassays are related to the low organic matter stability of composts and the enhanced release of decomposition endproducts, with the exception of earthworms, which are favored. Plant germination and collembolan reproduction inhibition was generally associated with uncomposted sludge, while earthworm total biomass and reproduction were enhanced by these materials. On the other hand, earthworm and collembolan survival were unaffected by the degree of composting of the wastes. However, this pattern was clear in one of the composting procedures assessed, but less in the other, where the release of decomposition endproducts was lower due to its higher stability, indicating the sensitivity and usefulness of bioassays for the quality assessment of composts.

  12. Biomonitoring of cyanotoxins in two tropical reservoirs by cladoceran toxicity bioassays.

    Science.gov (United States)

    da S Ferrão-Filho, Aloysio; Soares, Maria Carolina S; de Freitas Magalhães, Valeria; Azevedo, Sandra M F O

    2009-02-01

    This study evaluates the potential for the use of cladocerans in biomonitoring of cyanobacterial toxins. Two zooplankton species (Daphnia gessneri and Moina micrura) were cultivated in the laboratory for use in acute (48 h) and chronic (10 days) bioassays. Water samples were collected from two reservoirs and diluted in mineral water at four concentrations. Survivorship in the acute bioassays was used to calculate LC50, and survivorship and fecundity in chronic bioassays were used to calculate the intrinsic population growth rate (r) and the EC50. Analysis of phytoplankton in the water samples from one reservoir revealed that cyanobacteria were the dominant group, represented by the genera Anabaena, Cylindrospermopsis, and Microcystis. Results of bioassays showed adverse effects including death, paralysis, and reduced population growth rate, generally proportional to the reservoir water concentration. These effects may be related to the presence of cyanobacteria toxins (microcystins or saxitoxins) in the water.

  13. Establishment of a bioassay for the toxicity evaluation and quality control of Aconitum herbs

    International Nuclear Information System (INIS)

    Qin, Yi; Wang, Jia-bo; Zhao, Yan-ling; Shan, Li-mei; Li, Bao-cai; Fang, Fang; Jin, Cheng; Xiao, Xiao-he

    2012-01-01

    Highlights: ► A new bioassay was optimized to evaluate the toxicity of Aconitum herbs. ► Characterizing total toxicity is its unique advantage over chemical analysis methods. ► The application of this bioassay promotes the safe use of Aconitum herbs in clinic. - Abstract: Currently, no bioassay is available for evaluating the toxicity of Aconitum herbs, which are well known for their lethal cardiotoxicity and neurotoxicity. In this study, we established a bioassay to evaluate the toxicity of Aconitum herbs. Test sample and standard solutions were administered to rats by intravenous infusion to determine their minimum lethal doses (MLD). Toxic potency was calculated by comparing the MLD. The experimental conditions of the method were optimized and standardized to ensure the precision and reliability of the bioassay. The application of the standardized bioassay was then tested by analyzing 18 samples of Aconitum herbs. Additionally, three major toxic alkaloids (aconitine, mesaconitine, and hypaconitine) in Aconitum herbs were analyzed using a liquid chromatographic method, which is the current method of choice for evaluating the toxicity of Aconitum herbs. We found that for all Aconitum herbs, the total toxicity of the extract was greater than the toxicity of the three alkaloids. Therefore, these three alkaloids failed to account for the total toxicity of Aconitum herbs. Compared with individual chemical analysis methods, the chief advantage of the bioassay is that it characterizes the total toxicity of Aconitum herbs. An incorrect toxicity evaluation caused by quantitative analysis of the three alkaloids might be effectively avoided by performing this bioassay. This study revealed that the bioassay is a powerful method for the safety assessment of Aconitum herbs.

  14. The limits of two-year bioassay exposure regimens for identifying chemical carcinogens.

    Science.gov (United States)

    Huff, James; Jacobson, Michael F; Davis, Devra Lee

    2008-11-01

    Chemical carcinogenesis bioassays in animals have long been recognized and accepted as valid predictors of potential cancer hazards to humans. Most rodent bioassays begin several weeks after birth and expose animals to chemicals or other substances, including workplace and environmental pollutants, for 2 years. New findings indicate the need to extend the timing and duration of exposures used in the rodent bioassay. In this Commentary, we propose that the sensitivity of chemical carcinogenesis bio-assays would be enhanced by exposing rodents beginning in utero and continuing for 30 months (130 weeks) or until their natural deaths at up to about 3 years. Studies of three chemicals of different structures and uses-aspartame, cadmium, and toluene-suggest that exposing experimental animals in utero and continuing exposure for 30 months or until their natural deaths increase the sensitivity of bioassays, avoid false-negative results, and strengthen the value and validity of results for regulatory agencies. Government agencies, drug companies, and the chemical industry should conduct and compare the results of 2-year bioassays of known carcinogens or chemicals for which there is equivocal evidence of carcinogenicity with longer-term studies, with and without in utero exposure. If studies longer than 2 years and/or with in utero exposure are found to better identify potential human carcinogens, then regulatory agencies should promptly revise their testing guidelines, which were established in the 1960s and early 1970s. Changing the timing and dosing of the animal bioassay would enhance protection of workers and consumers who are exposed to potentially dangerous workplace or home contaminants, pollutants, drugs, food additives, and other chemicals throughout their lives.

  15. Efficacy of Enrofloxacin in a Mouse Model of Sepsis

    OpenAIRE

    Slate, Andrea R; Bandyopadhyay, Sheila; Francis, Kevin P; Papich, Mark G; Karolewski, Brian; Hod, Eldad A; Prestia, Kevin A

    2014-01-01

    We examined the efficacy of enrofloxacin administered by 2 different routes in a mouse model of sepsis. Male CD1 mice were infected with a bioluminescent strain of enteropathogenic Escherichia coli and treated with enrofloxacin either by injection or in drinking water. Peak serum levels were evaluated by using HPLC. Mice were monitored for signs of clinical disease, and infections were monitored by using bioluminescence imaging. Serum levels of enrofloxacin and the active metabolite ciproflox...

  16. Are bioassays useful tools to assess redox processes and biodegradation?

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Pedersen, Philip Grinder; Ludvigsen, L.

    2002-01-01

    sensitive hydrochemical or geochemical parameters, levels of hydrogen, and redox potential. However, all these approaches have to be evaluated against TEAP-bioassays as the most direct measure. We assessed successfully ongoing microbial-mediated redox processes by TEAP-bioassays in degradation studies...... of aromatic and chlorinated aliphatic compounds in landfill leachate plumes, and of pesticides in aquifers with various redox conditions....

  17. Comparison of solid and liquid-phase bioassays using ecoscores to assess contaminated soils

    International Nuclear Information System (INIS)

    Lors, Christine; Ponge, Jean-Francois; Martinez Aldaya, Maite; Damidot, Denis

    2011-01-01

    Bioassays on aqueous and solid phases of contaminated soils were compared, belonging to a wide array of trophic and response levels and using ecoscores for evaluating ecotoxicological and genotoxicological endpoints. The method was applied to four coke factory soils contaminated mainly with PAHs, but also to a lesser extent by heavy metals and cyanides. Aquatic bioassays do not differ from terrestrial bioassays when scaling soils according to toxicity but they are complementary from the viewpoint of ecological relevance. Both aquatic and terrestrial endpoints are strongly correlated with concentrations of 3-ring PAHs. This evaluation procedure allows us to propose a cost-effective battery which embraces a wide array of test organisms and response levels: it includes two rapid bioassays (Microtox) and springtail avoidance), a micronucleus test and three bioassays of a longer duration (algal growth, lettuce germination and springtail reproduction). This battery can be recommended for a cost-effective assessment of polluted/remediated soils. - Highlights: → Comparison of liquid- and solid-phase bioassays on contaminated soils, using ecoscores. → Complementarity of liquid- and solid-phase bioassays for the evaluation of environmental hazards. → Proposal for a restricted battery of 5 most sensitive tests. → Use of this restricted battery for a cost-effective assessment of polluted/remediated soils. - Aqueous and solid phases of contaminated soils give similar results in terms of toxicity but are complementary for the evaluation of environmental hazards by ecoscores.

  18. Paper-based chromatic toxicity bioassay by analysis of bacterial ferricyanide reduction.

    Science.gov (United States)

    Pujol-Vila, F; Vigués, N; Guerrero-Navarro, A; Jiménez, S; Gómez, D; Fernández, M; Bori, J; Vallès, B; Riva, M C; Muñoz-Berbel, X; Mas, J

    2016-03-03

    Water quality assessment requires a continuous and strict analysis of samples to guarantee compliance with established standards. Nowadays, the increasing number of pollutants and their synergistic effects lead to the development general toxicity bioassays capable to analyse water pollution as a whole. Current general toxicity methods, e.g. Microtox(®), rely on long operation protocols, the use of complex and expensive instrumentation and sample pre-treatment, which should be transported to the laboratory for analysis. These requirements delay sample analysis and hence, the response to avoid an environmental catastrophe. In an attempt to solve it, a fast (15 min) and low-cost toxicity bioassay based on the chromatic changes associated to bacterial ferricyanide reduction is here presented. E. coli cells (used as model bacteria) were stably trapped on low-cost paper matrices (cellulose-based paper discs, PDs) and remained viable for long times (1 month at -20 °C). Apart from bacterial carrier, paper matrices also acted as a fluidic element, allowing fluid management without the need of external pumps. Bioassay evaluation was performed using copper as model toxic agent. Chromatic changes associated to bacterial ferricyanide reduction were determined by three different transduction methods, i.e. (i) optical reflectometry (as reference method), (ii) image analysis and (iii) visual inspection. In all cases, bioassay results (in terms of half maximal effective concentrations, EC50) were in agreement with already reported data, confirming the good performance of the bioassay. The validation of the bioassay was performed by analysis of real samples from natural sources, which were analysed and compared with a reference method (i.e. Microtox). Obtained results showed agreement for about 70% of toxic samples and 80% of non-toxic samples, which may validate the use of this simple and quick protocol in the determination of general toxicity. The minimum instrumentation

  19. Inhibiting Effects of Achyranthes Bidentata Polysaccharide and Lycium Barbarum Polysaccharide on Nonenzyme Glycation in D-galactose Induced Mouse Aging Model

    Institute of Scientific and Technical Information of China (English)

    HONG-BIN DENG; DA-PENG CUI; JIAN-MING JIANG; YAN-CHUN FENG; NIAN-SHENG CAI; DIAN-DONG LI

    2003-01-01

    To investigate the inhibiting effects and mechanism of achyranthes bidentata polysaccharide (ABP) and lycium barbarum polysaccharide (LBP) on nonenzyme glycation in D-galactose induced mouse aging model. Methods Serum AGE levels were determined by AGE-ELISA, MTT method was used to determine lymphocyte proliferation, IL-2 activity was determined by a bioassay method. Spontaneous motor activity was used to detect mouse's neuromuscular movement, latency of step-through method was used to examine learning and memory abilities of mouse, colormetric assay was used to determine hydroxyproline concentration in mouse skin, pyrogallol autoxidation method was used to determine superoxide dismutase (SOD) activity of erythrocytes. Results Decreased levels of serum AGE, hydroxyproline concentration in mouse skin and spontaneous motor activity in D-galactose mouse aging model were detected after treated with ABP or LBP, while lymphocyte proliferation and IL-2 activity, learning and memory abilities,SOD activity of erythrocytes, were enhanced. Conclusions ABP and LBP could inhibit nonenzyme glycation in D-galactose induced mouse aging model in vivo and ABP has a better inhibiting effect than LBP.

  20. Manual on theory and practical aspects of bioassay

    International Nuclear Information System (INIS)

    Nuraini Hambali.

    1985-06-01

    This manual is set to provide necessary basic guidance on theory and practical aspects of bioassay specially for the newcomer in this field and the man in the laboratory. The first part is a brief information on the entry of radionuclides into the body, the metabolism and the programs of bioassay. All other factors to be considered in assessing internal contamination in man have also been brought up. In the second part, various procedures of radiochemical separations, detection and measurements are abstracted from journals and other revisions. Some methods have been attempted and to be followed where appropriate. (author)

  1. Exposure dose assessment using bioassay

    International Nuclear Information System (INIS)

    Suga, Shinichi

    1994-01-01

    Bioassay involves following steps: sampling, pre-treatment, chemical separation and counting of radioactivity. As bioassay samples, urines are usually used, although faecal analysis may be required in some occasions for example to assess intake of non-transferable radioactive materials. Nasal smear is a useful indicator of an inhalation case. Exhalation air is used to estimate the intake of tritiated water. Sample pre-treatment includes evaporation for concentration, wet ashing, dry ashing and co-precipitation. After adding small amount of nitric acid, the sample can be concentrated by 1/10 of initial volume, which may be used to identify γ-emitters. As the pre-treatment of urine, wet ashing is used for example for analysis of Pu, and co-precipitation is used for example for analysis of Sr. Dry ashing by electric furnace is usually adopted for faecal samples. Methods of chemical separation depend on the radionuclide(s) to be analysed. The detection limit depends also on radionuclide, and for example typical detection limits are 0.4Bq / l (volume of urine sample) for 89 Sr or 90 Sr, and 0.01 Bq / l with urine and 0.01 Bq per sample with faeces for 238 Pu, 239 Pu or 241 Am. Simpler methods can be used for some radionuclides: For example, radioactivity concentration of tritium can be determined by liquid scintillation counting of urine or condensed water from exhaled air, and natural uranium in urine can be quantified by using fluorometric method. In some circumstances, gross-α or gross-β analyses are useful for quick estimation. To estimate intakes by inhalation or by ingestion from bioassay results and to assess the committed dose equivalent, commonly available bases are the relevant publications by the ICRP and domestic guides and manuals that conform to the radiation protection regulations. (author)

  2. Review of literature on bioassay methods for estimating radionuclides in urine

    International Nuclear Information System (INIS)

    Prasad, M.V.R.; Surya Narayana, D.S.; Jeevanram, R.K.; Sundarajan, A.R.

    1991-01-01

    Bioassay methods of certain important radionuclides encountered in the nuclear fuel cycle operations, viz., thorium, uranium, sup(239)Pu, sup(241)Am, sup(90)Sr, sup(99)Tc, sup(106)Ru, sup(137)Cs are reviewed, with special emphasis on urinalysis. Since the preconcentration is an important prerequisite for bioassay, various preconcentration methods are also discussed. Brief account of various instruments both nuclear and analytical used in the bioassay programme is included. The sensitivities of the methods cited in the literature vis-a-vis the derived recording levels indicated in ICRP recommendations are compared. Literature surveyed up to 1990 is tabulated. (author). 96 refs., 1 fig ., 3 tabs

  3. Analysis of 'wet-landscape' surface water fractions using medaka embryo-toxicity bioassay

    Energy Technology Data Exchange (ETDEWEB)

    Peters, L. E.; McConkey, B. J.; Vanden Heuvel, M. R. (Waterloo, Univ., Dept, of Biology, Waterloo, ON (Canada)); MacKinnon, M. D. (Syncrude Canada Ltd., Fort McMurray, AB (Canada)) Munkittricx, K. (Environment Canada, Burlington, ON (Canada))

    1998-01-01

    The self-sustaining biological potential of Syncrude's 'wetland-scape' waste disposal method was evaluated by testing water extracts from experimental pits of different ages and fine tailings/natural water compositions. This waste disposal method involves capping fine tailings with a layer of surface water. Preliminary estimates suggests a higher incidence of mortality and deformity in Japanese Medaka embryos incubated in pit waters containing elevated concentrations of naphthenates. Another study on adult perch stocked in the demonstration pit indicated the presence of PAHs in the fish bile at biologically relevant concentrations. This study was designed to determine the causative agents of the fish embryo toxicity and the level of concentrations at which chronic effects occur. The water extracts were fractionated into acid (containing naphthenates) and base-neutral (containing PAHs) components and tested using the Japanese Medaka bioassay. Endpoints measured were the presence of deformity, hatch success, swim-bladder inflation, length at hatch and time to mortality. HPLC analysis showed that PAHs were present at concentrations in the part/billion and the parts/million range. This is being taken as an indication that PAHs are not directly responsible for the observed toxicity to the embryos.

  4. Worldwide bioassay data resources for plutonium/americium internal dosimetry studies

    International Nuclear Information System (INIS)

    Miller, G.; Bertelli, L.; Little, T.; Guilmette, R.; Riddell, T.; Filipy, R.

    2005-01-01

    Full text: Biokinetic models are the scientific underpinning of internal dosimetry. These models describe how materials of interest taken into the body by various routes (for example inhalation) are transported through the body, allowing the modelling of bioassay measurements and the estimation of radiation dose. The International Commission on Radiation Protection (ICRP) publishes biokinetic models for use in internal dosimetry. These models represent the consensus judgement of a committee of experts, based on human and animal data. Nonetheless, it is important to validate biokinetic models using directly applicable data, in a scientifically transparent manner, especially for internal dosimetry research purposes (as opposed to radiation protection), as in epidemiology studies. Two major goals would be to determine individual variations of model parameters for the purpose of assessing this source of uncertainty in internal dose calculations, and to determine values of workplace specific parameters (such as particle solubility in lung fluids) for different representative workplaces. Furthermore, data on the observed frequency of intakes under various conditions can be used in the interpretation of bioassay data. All of the above may be couched in the terminology of Bayesian statistical analysis and amount to the determination of the Bayesian prior probability distributions needed in a Bayesian interpretation of bioassay data. The authors have direct knowledge of several significant databases of plutonium/americium bioassay data (including autopsy data). The purpose of this paper is to acquaint the worldwide community with these resources and to invite others who may know of other such databases to participate with us in a publication that would document the content, form, and the procedures for seeking access to these databases. These databases represent a tremendous scientific resource in this field. Examples of databases known to the authors include: the

  5. [Application of bioassay in quality control of Chinese materia medica-taking Radix Isatidis as an example].

    Science.gov (United States)

    Yan, Dan; Ren, Yongshen; Luo, Jiaoyang; Li, Hanbing; Feng, Xue; Xiao, Xiaohe

    2010-10-01

    Bioassay, which construct the characteristics consistents with Chinese medical science, is the core mode and methods for the quality control of Chinese materia medica. Taking the bioassay of Radix Isatidis as an example, the contribution, status and application of bioassay in the quality control of Chinese materia medica were introduced in this article, and two key issue (the selection of reference and measurement methods) in the process of establishing bioassay were also explained. This article expects to provide a reference for the development and improvement of the bioassay of Chinese materia medica in a practical manipulation level.

  6. In vitro bioassays to evaluate complex chemical mixtures in recycled water

    Science.gov (United States)

    Jia, Ai; Escher, Beate I.; Leusch, Frederic D.L.; Tang, Janet Y.M.; Prochazka, Erik; Dong, Bingfeng; Snyder, Erin M.; Snyder, Shane A.

    2016-01-01

    With burgeoning population and diminishing availability of freshwater resources, the world continues to expand the use of alternative water resources for drinking, and the quality of these sources has been a great concern for the public as well as public health professionals. In vitro bioassays are increasingly being used to enable rapid, relatively inexpensive toxicity screening that can be used in conjunction with analytical chemistry data to evaluate water quality and the effectiveness of water treatment. In this study, a comprehensive bioassay battery consisting of 36 bioassays covering 18 biological endpoints was applied to screen the bioactivity of waters of varying qualities with parallel treatments. Samples include wastewater effluent, ultraviolet light (UV) and/or ozone advanced oxidation processed (AOP) recycled water, and infiltrated recycled groundwater. Based on assay sensitivity and detection frequency in the samples, several endpoints were highlighted in the battery, including assays for genotoxicity, mutagenicity, estrogenic activity, glucocorticoid activity, aryl hydrocarbon receptor activity, oxidative stress response, and cytotoxicity. Attenuation of bioactivity was found to be dependent on the treatment process and bioassay endpoint. For instance, ozone technology significantly removed oxidative stress activity, while UV based technologies were most efficient for the attenuation of glucocorticoid activity. Chlorination partially attenuated genotoxicity and greatly decreased herbicidal activity, while groundwater infiltration efficiently attenuated most of the evaluated bioactivity with the exception of genotoxicity. In some cases, bioactivity (e.g., mutagenicity, genotoxicity, and arylhydrocarbon receptor) increased following water treatment, indicating that transformation products of water treatment may be a concern. Furthermore, several types of bioassays with the same endpoint were compared in this study, which could help guide the selection

  7. US Army Radiological Bioassay and Dosimetry: The RBD software package

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Ward, R.C.; Maddox, L.B.

    1993-01-01

    The RBD (Radiological Bioassay and Dosimetry) software package was developed for the U. S. Army Material Command, Arlington, Virginia, to demonstrate compliance with the radiation protection guidance 10 CFR Part 20 (ref. 1). Designed to be run interactively on an IBM-compatible personal computer, RBD consists of a data base module to manage bioassay data and a computational module that incorporates algorithms for estimating radionuclide intake from either acute or chronic exposures based on measurement of the worker's rate of excretion of the radionuclide or the retained activity in the body. In estimating the intake,RBD uses a separate file for each radionuclide containing parametric representations of the retention and excretion functions. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent. For a given nuclide, if measurements exist for more than one type of assay, an auxiliary module, REPORT, estimates the intake by applying weights assigned in the nuclide file for each assay. Bioassay data and computed results (estimates of intake and committed dose equivalent) are stored in separate data bases, and the bioassay measurements used to compute a given result can be identified. The REPORT module creates a file containing committed effective dose equivalent for each individual that can be combined with the individual's external exposure

  8. BioAssay templates for the semantic web

    Directory of Open Access Journals (Sweden)

    Alex M. Clark

    2016-05-01

    Full Text Available Annotation of bioassay protocols using semantic web vocabulary is a way to make experiment descriptions machine-readable. Protocols are communicated using concise scientific English, which precludes most kinds of analysis by software algorithms. Given the availability of a sufficiently expressive ontology, some or all of the pertinent information can be captured by asserting a series of facts, expressed as semantic web triples (subject, predicate, object. With appropriate annotation, assays can be searched, clustered, tagged and evaluated in a multitude of ways, analogous to other segments of drug discovery informatics. The BioAssay Ontology (BAO has been previously designed for this express purpose, and provides a layered hierarchy of meaningful terms which can be linked to. Currently the biggest challenge is the issue of content creation: scientists cannot be expected to use the BAO effectively without having access to software tools that make it straightforward to use the vocabulary in a canonical way. We have sought to remove this barrier by: (1 defining a BioAssay Template (BAT data model; (2 creating a software tool for experts to create or modify templates to suit their needs; and (3 designing a common assay template (CAT to leverage the most value from the BAO terms. The CAT was carefully assembled by biologists in order to find a balance between the maximum amount of information captured vs. low degrees of freedom in order to keep the user experience as simple as possible. The data format that we use for describing templates and corresponding annotations is the native format of the semantic web (RDF triples, and we demonstrate some of the ways that generated content can be meaningfully queried using the SPARQL language. We have made all of these materials available as open source (http://github.com/cdd/bioassay-template, in order to encourage community input and use within diverse projects, including but not limited to our own

  9. Application of Bioassays for the Ecotoxicity Assessment of Contaminated Soils

    Science.gov (United States)

    Fernández, María D.; Babín, Mar; Tarazona, José V.

    The use of bioassays for soil characterization is receiving significant attention as a complementary tool to chemical analysis. Bioassays consist of direct toxicity assays of environmental samples that are transferred to the laboratory and analyzed for toxicity against selected organisms. Such soil samples contain the combination of the different pollutants present in situ and enable factors such as the bioavailability of contaminants or the interactions (synergic and antagonic) between them to be simultaneously studied.

  10. 7 Vascular Hydrophytes for Bioassay.cdr

    African Journals Online (AJOL)

    Administrator

    4 water (see Table 1). tool. The greater extension growth of macrophyte shoots in water from downstream of STWs (Fig. 1) was supported by both chemical analysis, which showed increased phosphate concentration (Table 1), and by conventional Selenastrum bioassay in which higher cell concentrations were achieved.

  11. Acquisition of HPLC-Mass Spectrometer

    Science.gov (United States)

    2015-08-18

    31-Jan-2015 Approved for Public Release; Distribution Unlimited Final Report: Acquisition of HPLC -Mass Spectrometer The views, opinions and/or findings...published in peer-reviewed journals: Final Report: Acquisition of HPLC -Mass Spectrometer Report Title The acquisition of the mass spectrometer has been a

  12. Bioassay-based risk assessment of hazardous waste

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, K.C.; Brown, K.W.; He, L.Y. [Texas A and M Univ., College Station, TX (United States)

    1994-12-31

    Microbial bioassays have been used to assess the genotoxic hazard at more than 30 different hazardous waste sites. Environmental samples were extracted with dichloromethane and methanol, and the resulting residue tested using GC/MS analysis as well as the Salmonella Microsomal and E. coli Prophage Induction assays. At a munitions wastewater contaminated site, there was no correlation between mutagenicity in bacteria, and the risk as estimated from chemical analysis data of trinitrotoluene. Samples 202 and 204 from a coal gasification site contained 72 mg/kg and 9 mg/kg benzo(a)pyrene, whereas the mutagenic responses of these samples were 231 net revertants/mg and 902 revertants/mg, respectively. The data suggest that microbial bioassays provide a valuable tool for monitoring the interactions of the components of a complex mixture.

  13. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils.

    OpenAIRE

    Lors , Christine; Ponge , Jean-François; Martínez Aldaya , Maite; Damidot , Denis

    2010-01-01

    International audience; Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the co...

  14. Interpretation of thorium bioassay data

    International Nuclear Information System (INIS)

    Juliao, L.M.Q.C.; Azeredo, A.M.G.F.; Santos, M.S.; Melo, D.R.; Dantas, B.M.; Lipsztein, J.L.

    1994-01-01

    A comparison have been made between bioassay data of thorium-exposed workers from two different facilities. The first of these facilities is a monazite sand extraction plant. Isotopic equilibrium between 232 Th and 238 Th was not observed in excreta samples of these workers. The second facility is a gas mantle factory. An isotopic equilibrium between 232 Th and 228 Th was observed in extra samples. Whole body counter measurements have indicated a very low intake of thorium through inhalation. As the concentration of thorium in feces was very high it was concluded that the main pathway of entrance of the nuclide was ingestion, mainly via contamination through dirty hands. The comparison between the bioassay results of workers from the two facilities shows that the lack of Th isotopic equilibrium observed in the excretion from the workers at the monazite sand plant possibly occurred due to an additional Th intake by ingestion of contaminated fresh food. This is presumably because 228 Ra is more efficiently taken up from the soil by plants, in comparison to 228 Th or 232 Th, and subsequently, 228 Th grows in from its immediate parent, 228 Ra. (author) 5 refs.; 3 tabs

  15. Micro-organism distribution sampling for bioassays

    Science.gov (United States)

    Nelson, B. A.

    1975-01-01

    Purpose of sampling distribution is to characterize sample-to-sample variation so statistical tests may be applied, to estimate error due to sampling (confidence limits) and to evaluate observed differences between samples. Distribution could be used for bioassays taken in hospitals, breweries, food-processing plants, and pharmaceutical plants.

  16. Initial sample extract stock concentration affects in vitro bioassay-based toxicological risk characterization

    NARCIS (Netherlands)

    Montano, M.; Loffmann, L.; Murk, A.J.; Gutleb, A.C.

    2014-01-01

    Purpose Bioassays have become an alternative for sediment risk profiling, including potential compliance with sediment quality criteria (SQC). In vitro functional bioassays have evolved through standardization and validation towards a confident toxicological hazard estimate of sediments. Sample

  17. Activities of Jatropha curcas phorbol esters in various bioassays.

    Science.gov (United States)

    Devappa, Rakshit K; Rajesh, Sanjay K; Kumar, Vikas; Makkar, Harinder P S; Becker, Klaus

    2012-04-01

    Jatropha curcas seeds contain 30-35% oil, which can be converted to high quality biodiesel. However, Jatropha oil is toxic, ascribed to the presence of phorbol esters (PEs). In this study, isolated phorbol ester rich fraction (PEEF) was used to evaluate the activity of PEs using three aquatic species based bioassays (snail (Physa fontinalis), brine shrimp (Artemeia salina), daphnia (Daphnia magna)) and microorganisms. In all the bioassays tested, increase in concentration of PEs increased mortality with an EC(50) (48 h) of 0.33, 26.48 and 0.95 mg L(-1) PEs for snail, artemia and daphnia, respectively. The sensitivity of various microorganisms for PEs was also tested. Among the bacterial species tested, Streptococcus pyogenes and Proteus mirabilis were highly susceptible with a minimum inhibitory concentration (MIC) of 215 mg L(-1) PEs; and Pseudomonas putida were also sensitive with MIC of 251 mg L(-1) PEs. Similarly, Fusarium species of fungi exhibited EC(50) of 58 mg L(-1) PEs, while Aspergillus niger and Curvularia lunata had EC(50) of 70 mg L(-1). The snail bioassay was most sensitive with 100% snail mortality at 1 μg of PEs mL(-1). In conclusion, snail bioassay could be used to monitor PEs in Jatropha derived products such as oil, biodiesel, fatty acid distillate, kernel meal, cake, glycerol or for contamination in soil or other environmental matrices. In addition, PEs with molluscicidal/antimicrobial activities could be utilized for agricultural and pharmaceutical applications. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Soil plate bioassay: an effective method to determine ecotoxicological risks.

    Science.gov (United States)

    Boluda, R; Roca-Pérez, L; Marimón, L

    2011-06-01

    Heavy metals have become one of the most serious anthropogenic stressors for plants and other living organisms. Having efficient and feasible bioassays available to assess the ecotoxicological risks deriving from soil pollution is necessary. This work determines pollution by Cd, Co, Cr, Cu, Ni, Pb, V and Zn in two soils used for growing rice from the Albufera Natural Park in Valencia (Spain). Both were submitted to a different degree of anthropic activity, and their ecotoxicological risk was assessed by four ecotoxicity tests to compare their effectiveness: Microtox test, Zucconi test, pot bioassay (PB) and soil plate bioassay (SPB). The sensitivity of three plant species (barley, cress and lettuce) was also assessed. The results reveal a different degree of effectiveness and level of inhibition in the target organisms' growth depending on the test applied, to such an extent that the one-way analysis of variance showed significant differences only for the plate bioassay results, with considerable inhibition of root and shoot elongation in seedlings. Of the three plant species selected, lettuce was the most sensitive species to toxic effects, followed by cress and barley. Finally, the results also indicate that the SPB is an efficient, simple and economic alternative to other ecotoxicological assays to assess toxicity risks deriving from soil pollution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. In vitro bioassays to evaluate complex chemical mixtures in recycled water.

    Science.gov (United States)

    Jia, Ai; Escher, Beate I; Leusch, Frederic D L; Tang, Janet Y M; Prochazka, Erik; Dong, Bingfeng; Snyder, Erin M; Snyder, Shane A

    2015-09-01

    With burgeoning population and diminishing availability of freshwater resources, the world continues to expand the use of alternative water resources for drinking, and the quality of these sources has been a great concern for the public as well as public health professionals. In vitro bioassays are increasingly being used to enable rapid, relatively inexpensive toxicity screening that can be used in conjunction with analytical chemistry data to evaluate water quality and the effectiveness of water treatment. In this study, a comprehensive bioassay battery consisting of 36 bioassays covering 18 biological endpoints was applied to screen the bioactivity of waters of varying qualities with parallel treatments. Samples include wastewater effluent, ultraviolet light (UV) and/or ozone advanced oxidation processed (AOP) recycled water, and infiltrated recycled groundwater. Based on assay sensitivity and detection frequency in the samples, several endpoints were highlighted in the battery, including assays for genotoxicity, mutagenicity, estrogenic activity, glucocorticoid activity, arylhydrocarbon receptor activity, oxidative stress response, and cytotoxicity. Attenuation of bioactivity was found to be dependent on the treatment process and bioassay endpoint. For instance, ozone technology significantly removed oxidative stress activity, while UV based technologies were most efficient for the attenuation of glucocorticoid activity. Chlorination partially attenuated genotoxicity and greatly decreased herbicidal activity, while groundwater infiltration efficiently attenuated most of the evaluated bioactivity with the exception of genotoxicity. In some cases, bioactivity (e.g., mutagenicity, genotoxicity, and arylhydrocarbon receptor) increased following water treatment, indicating that transformation products of water treatment may be a concern. Furthermore, several types of bioassays with the same endpoint were compared in this study, which could help guide the selection

  20. Sensitive detectors in HPLC

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Detection of sample components in HPLC is difficult for many reasons; the key difficulty is the mobile phase which usually has properties similar to the solute. A variety of detectors have been developed for use in HPLC based on one of the above approaches; however, the search is still continuing for an ideal or universal detector. A universal detector should have the following characteristics: (1) responds to all solutes or has predictable specificity; (2) high detectability and the same predictable response; (3) fast response; (4) wide range of linearity; (5) unaffected by changes in temperature and mobile-phase flow; (6) responds independently of the mobile phase; (7) makes no contribution to extracolumn band broadening; (8) reliable and convenient to use; (9) nondestructive to the solute; (10) provides qualitative information on the detected peak. Unfortunately, no available HPLC detector possesses all these properties. 145 refs

  1. HPLC: Early and Recent Perspectives.

    Science.gov (United States)

    Karger, Barry L.

    1997-01-01

    Provides a perspective on what it was like in the early days of high-performance liquid chromatography (HPLC) and several of the key developments. Focuses on the advances in HPLC generally, and more specifically for the biological sciences, that were necessary for the method to reach the preeminent stage of today. Contains 20 references. (JRH)

  2. Spinal cord neuronotrophic factors (SCNTFs): I. Bioassay of schwannoma and other conditioned media.

    Science.gov (United States)

    Longo, F M; Manthorpe, M; Varon, S

    1982-02-01

    We present a procedure for the dissociation and growth in serum-free defined culture medium of 4-day chick embryo lumbar spinal cord (LC4) neurons. LC4 neurons will not survive for even 24 h without the addition of trophic supplements (putative spinal cord neuronotrophic factors, SCNTFs). Serum-free medium conditioned over chick embryo heart and skeletal muscle, mouse Schwann and rat RN22 Schwannoma cell cultures were found to contain SCNTF activity which could be quantitated using a convenient neuronal survival bioassay. RN22 conditioned medium also contains polyornithine-binding neurite promoting factors (PNPFs) which can be physically separated from SCNTF. When SCNTF and PNPF were presented to LC4 neurons individually or in combination (i) SCNTF, but not PNPF, supported neuronal survival whereas (ii) PNPF, but not SCNTF, induced neurite production. When LC4 neurons were grown in SCNTF alone, nearly all of them exhibited a flattened, circular, 'fried-egg' morphology. The subsequent addition of PNPF caused these cells to extend long neurites with characteristic terminal growth-cone-like structures.

  3. Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

    Science.gov (United States)

    Mustafa, Ahmed M; Caprioli, Giovanni; Ricciutelli, Massimo; Maggi, Filippo; Marín, Rosa; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twenty samples showed that gentiopicroside is the most dominant compound (1.85-3.97%), followed by loganic acid (0.11-1.30%), isogentisin (0.03-0.48%), sweroside (0.05-0.35%), swertiamarin (0.08-0.30%), and amarogentin (0.01-0.07%). The results confirmed the high quality of the G.lutea cultivated in the Monti Sibillini National Park. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Evaluation of the toxicity of two soils from Jales Mine (Portugal) using aquatic bioassays.

    Science.gov (United States)

    Loureiro, Susana; Ferreira, Abel L G; Soares, Amadeu M V M; Nogueira, António J A

    2005-10-01

    Soil contamination can be one path for streams and groundwater contamination. As a complement of chemical analysis and total contaminants determination, bioassays can provide information on the bioavailable fraction of chemical compounds, focusing on the retention and habitat function of soils. In this study the evaluation of the toxicity of two soils from the abandoned Jales Mine (Portugal) regarded both functions. The buffer capacity of soils was tested with bioassays carried out using the cladoceran Daphnia magna and the marine bacteria Vibrio fischeri. The habitat function of soils was evaluated with the reproduction bioassay with the collembolan Folsomia candida. The Microtox solid-phase test was performed with V. fischeri using soil as test medium, and soil elutriates were extracted to perform the Microtox basic test, and an immobilization and reproduction bioassay with D. magna. The marine bacteria showed high sensitivity to the soil with low heavy metal content (JNC soil) and to JNC soil elutriates, while the soil with highest heavy metal content (JC soil) or soil elutriates exposure did not cause any toxic effect. In the bioassays with D. magna, organisms showed sensitivity to JNC and also to JC soil elutriates. Both mobilization and reproduction features were inhibited. The bioassay with F. candida did not reflect any influence of the contaminants on their reproduction. Although JNC soil presented lower heavy metal contents, elutriates showed different patterns of contamination when compared to JC soil and elutriates, which indicates different retention and buffer capacities between soils. Results obtained in this study underlined the sensitivity and importance of soil elutriate bioassays with aquatic organisms in the evaluation strategy in soil ERA processes.

  5. Benchmarking organic micropollutants in wastewater, recycled water and drinking water with in vitro bioassays.

    Science.gov (United States)

    Escher, Beate I; Allinson, Mayumi; Altenburger, Rolf; Bain, Peter A; Balaguer, Patrick; Busch, Wibke; Crago, Jordan; Denslow, Nancy D; Dopp, Elke; Hilscherova, Klara; Humpage, Andrew R; Kumar, Anu; Grimaldi, Marina; Jayasinghe, B Sumith; Jarosova, Barbora; Jia, Ai; Makarov, Sergei; Maruya, Keith A; Medvedev, Alex; Mehinto, Alvine C; Mendez, Jamie E; Poulsen, Anita; Prochazka, Erik; Richard, Jessica; Schifferli, Andrea; Schlenk, Daniel; Scholz, Stefan; Shiraishi, Fujio; Snyder, Shane; Su, Guanyong; Tang, Janet Y M; van der Burg, Bart; van der Linden, Sander C; Werner, Inge; Westerheide, Sandy D; Wong, Chris K C; Yang, Min; Yeung, Bonnie H Y; Zhang, Xiaowei; Leusch, Frederic D L

    2014-01-01

    Thousands of organic micropollutants and their transformation products occur in water. Although often present at low concentrations, individual compounds contribute to mixture effects. Cell-based bioassays that target health-relevant biological endpoints may therefore complement chemical analysis for water quality assessment. The objective of this study was to evaluate cell-based bioassays for their suitability to benchmark water quality and to assess efficacy of water treatment processes. The selected bioassays cover relevant steps in the toxicity pathways including induction of xenobiotic metabolism, specific and reactive modes of toxic action, activation of adaptive stress response pathways and system responses. Twenty laboratories applied 103 unique in vitro bioassays to a common set of 10 water samples collected in Australia, including wastewater treatment plant effluent, two types of recycled water (reverse osmosis and ozonation/activated carbon filtration), stormwater, surface water, and drinking water. Sixty-five bioassays (63%) showed positive results in at least one sample, typically in wastewater treatment plant effluent, and only five (5%) were positive in the control (ultrapure water). Each water type had a characteristic bioanalytical profile with particular groups of toxicity pathways either consistently responsive or not responsive across test systems. The most responsive health-relevant endpoints were related to xenobiotic metabolism (pregnane X and aryl hydrocarbon receptors), hormone-mediated modes of action (mainly related to the estrogen, glucocorticoid, and antiandrogen activities), reactive modes of action (genotoxicity) and adaptive stress response pathway (oxidative stress response). This study has demonstrated that selected cell-based bioassays are suitable to benchmark water quality and it is recommended to use a purpose-tailored panel of bioassays for routine monitoring.

  6. Literatuuronderzoek HPLC-methoden voor vitamine E

    OpenAIRE

    Altena, A.; Hollman, P.C.H.

    1985-01-01

    Doel van dit onderzoek is: het inventariseren van HPLC-methoden voor vitamine E, eventueel in combinatie met vitamine A, in levensmiddelen. Een overzicht van de in de literatuur beschreven HPLC-methoden vanaf ca. 1977 wordt gegeven.

  7. A versatile electrowetting-based digital microfluidic platform for quantitative homogeneous and heterogeneous bio-assays

    Science.gov (United States)

    Vergauwe, Nicolas; Witters, Daan; Ceyssens, Frederik; Vermeir, Steven; Verbruggen, Bert; Puers, Robert; Lammertyn, Jeroen

    2011-05-01

    Electrowetting-on-dielectric (EWOD) lab-on-a-chip systems have already proven their potential within a broad range of bio-assays. Nevertheless, research on the analytical performance of those systems is limited, yet crucial for a further breakthrough in the diagnostic field. Therefore, this paper presents the intrinsic possibilities of an EWOD lab-on-a-chip as a versatile platform for homogeneous and heterogeneous bio-assays with high analytical performance. Both droplet dispensing and splitting cause variations in droplet size, thereby directly influencing the assay's performance. The extent to which they influence the performance is assessed by a theoretical sensitivity analysis, which allows the definition of a basic framework for the reduction of droplet size variability. Taking advantage of the optimized droplet manipulations, both homogeneous and heterogeneous bio-assays are implemented in the EWOD lab-on-a-chip to demonstrate the analytical capabilities and versatility of the device. A fully on-chip enzymatic assay is realized with high analytical performance. It demonstrates the promising capabilities of an EWOD lab-on-a-chip in food-related and medical applications, such as nutritional and blood analyses. Further, a magnetic bio-assay for IgE detection using superparamagnetic nanoparticles is presented whereby the nanoparticles are used as solid carriers during the bio-assay. Crucial elements are the precise manipulation of the superparamagnetic nanoparticles with respect to dispensing and separation. Although the principle of using nano-carriers is demonstrated for protein detection, it can be easily extended to a broader range of bio-related applications like DNA sensing. In heterogeneous bio-assays the chip surface is actively involved during the execution of the bio-assay. Through immobilization of specific biological compounds like DNA, proteins and cells a reactive chip surface is realized, which enhances the bio-assay performance. To demonstrate

  8. Improving global laboratory capabilities for emergency radionuclide bioassay

    International Nuclear Information System (INIS)

    Li, C.; Jourdain, J.; Kramer, G. H.

    2012-01-01

    During a radiological or nuclear emergency, first-responders and the general public may be internally contaminated with the radionuclide(s) involved. A timely radionuclide bioassay provides important information about contamination, for subsequent dose assessment and medical management. Both technical and operational gaps are discussed in this paper. As many people may need to be assessed in a short period of time, any single laboratory may find its capabilities insufficient. Laboratories from other regions or other countries may be called upon for assistance. This paper proposes a road-map to improve global capabilities in emergency radionuclide bioassay, suggesting a phased approach for establishing a global laboratory network. Existing international collaboration platforms could provide the base on which to build such a network. (authors)

  9. PET/CT imaging of c-Myc transgenic mice identifies the genotoxic N-nitroso-diethylamine as carcinogen in a short-term cancer bioassay.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available BACKGROUND: More than 100,000 chemicals are in use but have not been tested for their safety. To overcome limitations in the cancer bioassay several alternative testing strategies are explored. The inability to monitor non-invasively onset and progression of disease limits, however, the value of current testing strategies. Here, we report the application of in vivo imaging to a c-Myc transgenic mouse model of liver cancer for the development of a short-term cancer bioassay. METHODOLOGY/PRINCIPAL FINDINGS: μCT and ¹⁸F-FDG μPET were used to detect and quantify tumor lesions after treatment with the genotoxic carcinogen NDEA, the tumor promoting agent BHT or the hepatotoxin paracetamol. Tumor growth was investigated between the ages of 4 to 8.5 months and contrast-enhanced μCT imaging detected liver lesions as well as metastatic spread with high sensitivity and accuracy as confirmed by histopathology. Significant differences in the onset of tumor growth, tumor load and glucose metabolism were observed when the NDEA treatment group was compared with any of the other treatment groups. NDEA treatment of c-Myc transgenic mice significantly accelerated tumor growth and caused metastatic spread of HCC in to lung but this treatment also induced primary lung cancer growth. In contrast, BHT and paracetamol did not promote hepatocarcinogenesis. CONCLUSIONS/SIGNIFICANCE: The present study evidences the accuracy of in vivo imaging in defining tumor growth, tumor load, lesion number and metastatic spread. Consequently, the application of in vivo imaging techniques to transgenic animal models may possibly enable short-term cancer bioassays to significantly improve hazard identification and follow-up examinations of different organs by non-invasive methods.

  10. 3,3',5-Triiodo-L-thyronine-like activity in effluents from domestic sewage treatment plants detected by in vitro and in vivo bioassays

    International Nuclear Information System (INIS)

    Murata, Tomonori; Yamauchi, Kiyoshi

    2008-01-01

    Thyroid system-disrupting activity in effluents from municipal domestic sewage treatment plants was detected using three in vitro assays and one in vivo assay. Contaminants in the effluents were extracted by solid-phase extraction (SPE) and eluted stepwise with different organic solvents. The majority of the thyroid system-disrupting activity was detected in the dichloromethane/methanol (1/1) fraction after SPE in all three in vitro assays: competitive assays of 3,3',5-[ 125 I]triiodo-L-thyronine ([ 125 I]T 3 ) binding to the plasma protein transthyretin (TTR assay) and thyroid hormone receptor (TR assay) and T 3 -dependent luciferase assay (Luc assay). Subsequent reverse-phase high-performance liquid chromatography (RP-HPLC) of the dichloromethane/methanol (1/1) fraction separated contaminants potent in the TR and Luc assays from those potent in the TTR assay. The contaminants potent in the TR and Luc assays were also potent in an in vivo short-term gene expression assay in Xenopus laevis (Tadpole assay). The present study demonstrated that the effluents from domestic sewage treatment plants contain contaminants with T 3 -like activity of ∼ 10 -10 M T 3 -equivalent concentration (T 3 EQ) and that the TR and Luc assays are powerful in vitro bioassays for detecting thyroid system-disrupting activity in effluents. The availability and applicability of these bioassays for screening contaminants with thyroid system-disrupting activity in the water environment are discussed

  11. Re-purification of labelled ferritin antigen with HPLC

    International Nuclear Information System (INIS)

    Zhang Haoyi; Jin Lichun

    2002-01-01

    Objective: To improve the quality of long-term stored labelled ferritin antigen with HPLC. Methods: The antigen was analyzed and purified with HPLC and again analyzed with RIA afterwards. Results: Ferritin antigen underwent significant polymerization after long-term (aggregation) storage. After re-purification with HPLC, its immuno-activity and labelled specific radioactivity were both significantly improved. Conclusion: Quality of stored ferritin RIA kit could be greatly improved after re-purification with HPLC

  12. The use of bioassays to assess the toxicity of sediment in an acid ...

    African Journals Online (AJOL)

    Exposure of river sediment from 7 sampling sites to these bioassays provided an eco-toxicological estimation of the acute toxicity and chronic toxicity emanating from the contaminated sediments. Physico-chemical analyses revealed higher levels of sediment contamination closer to the mine. The bioassays displayed a ...

  13. Sample preparation for combined chemical analysis and bioassay application in water quality assessment

    NARCIS (Netherlands)

    Kolkman, A.; Schriks, M.; Brand, W; Bäuerlein, P.S.; van der Kooi, M.M.E.; van Doorn, R.H.; Emke, E.; Reus, A.; van der Linden, S.; de Voogt, P.; Heringa, M.B.

    2013-01-01

    The combination of in vitro bioassays and chemical screening can provide a powerful toolbox to determine biologically relevant compounds in water extracts. In this study, a sample preparation method is evaluated for the suitability for both chemical analysis and in vitro bioassays. A set of 39

  14. The CALUX bioassay: current status of its application to screening food and feed

    NARCIS (Netherlands)

    Hoogenboom, L.A.P.; Goeyens, L.; Carbonnelle, S.; Loco, van J.; Beernaert, H.; Baeyens, W.; Traag, W.A.; Bovee, T.F.H.; Jacobs, G.; Schoeters, G.

    2006-01-01

    The CALUX bioassay is at present the best screening method for dioxins and dioxin-like (dl) polychlorinated biphenyls (PCBs) in food and feed, and the only assay used in routine monitoring and during larger incidents. Furthermore, the use of bioassays in addition to chemical reference methods allows

  15. Assessment of acrylamide toxicity using a battery of standardised bioassays.

    Science.gov (United States)

    Zovko, Mira; Vidaković-Cifrek, Željka; Cvetković, Želimira; Bošnir, Jasna; Šikić, Sandra

    2015-12-01

    Acrylamide is a monomer widely used as an intermediate in the production of organic chemicals, e.g. polyacrylamides (PAMs). Since PAMs are low cost chemicals with applications in various industries and waste- and drinking water treatment, a certain amount of non-polymerised acrylamide is expected to end up in waterways. PAMs are non-toxic but acrylamide induces neurotoxic effects in humans and genotoxic, reproductive, and carcinogenic effects in laboratory animals. In order to evaluate the effect of acrylamide on freshwater organisms, bioassays were conducted on four species: algae Desmodesmus subspicatus and Pseudokirchneriella subcapitata, duckweed Lemna minor and water flea Daphnia magna according to ISO (International Organization for Standardisation) standardised methods. This approach ensures the evaluation of acrylamide toxicity on organisms with different levels of organisation and the comparability of results, and it examines the value of using a battery of low-cost standardised bioassays in the monitoring of pollution and contamination of aquatic ecosystems. These results showed that EC50 values were lower for Desmodesmus subspicatus and Pseudokirchneriella subcapitata than for Daphnia magna and Lemna minor, which suggests an increased sensitivity of algae to acrylamide. According to the toxic unit approach, the values estimated by the Lemna minor and Daphnia magna bioassays, classify acrylamide as slightly toxic (TU=0-1; Class 1). The results obtained from algal bioassays (Desmodesmus subspicatus and Pseudokirchneriella subcapitata) revealed the toxic effect of acrylamide (TU=1-10; Class 2) on these organisms.

  16. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  17. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Lors, Christine [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France); Centre National de Recherche sur les Sites et Sols Pollues, 930 Boulevard Lahure, BP 537, 59505 Douai Cedex (France); Ponge, Jean-Francois, E-mail: ponge@mnhn.f [Museum National d' Histoire Naturelle, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Martinez Aldaya, Maite [Museum National d' Histoire Naturelle, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Damidot, Denis [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France)

    2010-08-15

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. - The avoidance test using the soil springtail Folsomia candida is globally more sensitive to PAH contamination than acute and chronic toxicity bioassays using plants and animals but a battery of tests could reveal better in detail.

  18. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils

    International Nuclear Information System (INIS)

    Lors, Christine; Ponge, Jean-Francois; Martinez Aldaya, Maite; Damidot, Denis

    2010-01-01

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. - The avoidance test using the soil springtail Folsomia candida is globally more sensitive to PAH contamination than acute and chronic toxicity bioassays using plants and animals but a battery of tests could reveal better in detail.

  19. Dermal oncogenicity bioassays of monofunctional and multifunctional acrylates and acrylate-based oligomers.

    Science.gov (United States)

    DePass, L R; Maronpot, R R; Weil, C S

    1985-01-01

    Several important components of photocurable coatings were studied for dermal tumorigenic activity by repeated application to the skin of mice. The substances tested were 2-ethylhexyl acrylate (EHA) and methylcarbamoyloxyethyl acrylate (MCEA) (monomers); neopentyl glycol diacrylate (NPGDA), esterdiol-204-diacrylate (EDDA), and pentaerythritol tri(tetra)acrylate (PETA) (cross-linkers); and three acrylated urethane oligomers. For each bioassay, 40 C3H/HeJ male mice were dosed 3 times weekly on the dorsal skin for their lifetime with the highest dose of the test agent that caused no local irritation or reduction in body weight gain. Two negative control groups received acetone (diluent) only. A positive control group received 0.2% methylcholanthrene (MC). NPGDA and EHA had significant tumorigenic activity with tumor yields of eight and six tumor-bearing mice (three and two malignancies), respectively. The MC group had 34 mice with carcinomas and 1 additional mouse with a papilloma. MCEA had no dermal tumorigenic activity but resulted in early mortality. No skin tumors in the treatment area were observed in the other groups. Additional studies will be necessary to elucidate possible relationships between structure and tumorigenic activity for the acrylates.

  20. Experience with NQA-1 quality assurance standards applied to in vitro bioassay

    International Nuclear Information System (INIS)

    Bihl, D.E.; MacLellan, J.A.

    1991-10-01

    On June 1, 1990, the large (about 4000 samples per year) excreta bioassay program at the Hanford Site ceased abruptly when the contract with the bioassay laboratory was terminated. An intense, high-priority effort was begun to replace the services on an interim basis until a new contract could be procured. Despite the urgency to get the excreta bioassay program going again, the Hanford Internal Dosimetry Program was constrained to use only labs that could meet stringent quality assurance (QA) requirements, even during the interim period. The QA requirements were based on NQA-1 with selected additions from the Environmental Protection Agency's QAMS 005/80 (EPA 1983) and the American Society for Testing and Materials' C 1009-83 (ASTM 1984). This constraint was driven both by legal reasons and by the Hanford Site contractors and workers not wanting the quality of the data to be sacrificed. Finding labs that could (1) handle the large throughput, (2) meet the technical requirements, and (3) pass the QA audit proved more difficult than first anticipated. This presentation focuses on the QA requirements that the labs had to meet and how those very broad requirements were applied specifically to excreta bioassay. 5 refs

  1. Experience with NQA-1 quality assurance standards applied to in vitro bioassay

    International Nuclear Information System (INIS)

    Bihl, D.E.; MacLellan, J.A.

    1991-01-01

    On June 1, 1990, the large (about 4,000 samples per year) excreta bioassay program at the Hanford Site ceased abruptly when the contract with the bioassay laboratory was terminated. An intense, high-priority effort was begun to replace the services on an interim basis until a new contract could be procured. Despite the urgency to get the excreta bioassay program going again, the Hanford Internal Dosimetry Program was constrained to use only labs that could meet stringent quality assurance (QA) requirements, even during the interim period. The QA requirements were based on NQA-1 with selected additions from the Environmental Protection Agency's QAMS 005/80 (EPA 1983) and the American Society for Testing and Materials' C 1009-83 (ASTM 1984). This constraint was driven both by legal reasons and by the Hanford Site contractors and workers not wanting the quality of the data to be sacrificed. Finding labs that could (1) handle the large throughput, (2) meet the technical requirements, and (3) pass the QA audit proved more difficult than first anticipated. This presentation focuses on the QA requirements that the labs had to meet and how those very broad requirements were applied specifically to excreta bioassay

  2. Enhancement of mouse sperm motility by trophinin-binding peptide

    Directory of Open Access Journals (Sweden)

    Park Seong

    2012-11-01

    Full Text Available Abstract Background Trophinin is an intrinsic membrane protein that forms a complex in the cytoplasm with bystin and tastin, linking it microtubule-associated motor dynein (ATPase in some cell types. Previously, we found that human sperm tails contain trophinin, bystin and tastin proteins, and that trophinin-binding GWRQ (glycine, tryptophan, arginine, glutamine peptide enhanced motility of human sperm. Methods Immunohistochemistry was employed to determine trophinin protein in mouse spermatozoa from wild type mouse, by using spermatozoa from trophinin null mutant mice as a negative control. Multivalent 8-branched GWRQ (glycine, tryptophan, arginine, glutamine peptide or GWRQ-MAPS, was chemically synthesized, purified by HPLC and its structure was confirmed by MALDI-TOF mass spectrometry. Effect of GWRQ-MAPS on mouse spermatozoa from wild type and trophinin null mutant was assessed by a computer-assisted semen analyzer (CASA. Results Anti-trophinin antibody stained the principal (central piece of the tail of wild type mouse sperm, whereas the antibody showed no staining on trophinin null sperm. Phage particles displaying GWRQ bound to the principal piece of sperm tail from wild type but not trophinin null mice. GWRQ-MAPS enhanced motility of spermatozoa from wild type but not trophinin null mice. CASA showed that GWRQ-MAPS enhanced both progressive motility and rapid motility in wild type mouse sperm. Conclusions Present study established the expression of trophinin in the mouse sperm tail and trophinin-dependent effect of GWRQ-MAPS on sperm motility. GWRQ causes a significant increase in sperm motility.

  3. The 10th Annual Bioassays and Bioanalytical Method Development Conference.

    Science.gov (United States)

    Ma, Mark; Tudan, Christopher; Koltchev, Dolly

    2015-01-01

    The 10th Annual Bioassays and Bioanalytical Method Development Conference was hosted in Boston, MA, USA on 20-22 October 2014. This meeting brought together scientists from the biopharmaceutical and life sciences industries, the regulatory agency and academia to share and discuss current trends in cell-based assays and bioanalysis, challenges and ideas for the future of the bioassays and bioanalytical method development. The experiences associated with new and innovative technologies were evaluated as well as their impact on the current bioassays methodologies and bioanalysis workflow, including quality, feasibility, outsourcing strategies and challenges, productivity and compliance. Several presentations were also provided by members of the US FDA, sharing both scientific and regulatory paradigms including a most recent update on the position of the FDA with specific aspects of the draft Bioanalytical Method Validation guidance following its review of the industry's responses. The meeting was jointly coincided with the 15th Annual Immunogenicity for Biotherapeutics meeting, allowing for attendees to also familiarize themselves with new and emerging approaches to overcome the effect of immunogenicity, in addition to investigative strategies.

  4. [Development of Tianma HPLC fingerprint and discriminant analysis].

    Science.gov (United States)

    Xiao, Jia-Jia; Huang, Hong; Lei, You-Cheng; Lin, Ting-Wen; Ma, Yue; Zhang, Jing; Zhang, Xing-Guo; Zhang, Da-Quan; Lv, Guang-Hua

    2017-07-01

    Tianma(the tuber of Gastrodia eleta) is a widely used and pricy Chinese herb. Its counterfeits are often found in herbal markets, which are the plant materials with similar macroscopic characteristics of Tianma. Moreover, the prices of Winter Tianma(cultivated Tianma) and Spring Tianma(mostly wild Tianma) have significant difference. However, it is difficult to identify the true or false, good or bad quality of Tianma samples. Thus, a total of 48 Tianma samples with different characteristics(including Winter Tianma, Spring Tianma, slice, powder, etc.) and 9 plant species 10 samples of Tianma counterfeits were collected and analyzed by HPLC-DAD-MS techniques. After optimizing the procedure of sample preparation, chromatographic and mass-spectral conditions, the HPLC chromatograms of all those samples were collected and compared. The similarities and Fisher discriminant analysis were further conducted between the HPLC chromatograms of Tianma and counterfeit, Winter Tianma and Spring Tianma. The results showed the HPLC chromatograms of 48 Tianma samples were similar at the correlation coefficient more than 0.848(n=48). Their mean chromatogram was simulated and used as Tianma HPLC fingerprint. There were 11 common peaks on the HPLC chromatograms of Tianma, in which 6 main peaks were chosen as characteristic peaks and identified as gastrodin, p-hydroxybenzyl alcohol, parishin A, parishin B, parishin C, parishin E, respectively by comparison of the retention time, UV and MS data with those of standard chemical compounds. All the six chemical compounds are bioactive in Tianma. However, the HPLC chromatograms of the 10 counterfeit samples were significantly different from Tianma fingerprint. The correlation coefficients between HPLC fingerprints of Tianma with the HPLC chromatograms of counterfeits were less than 0.042 and the characteristic peaks were not observed on the HPLC chromatograms of these counterfeit samples. It indicated the true or false Tianma can be

  5. 9 CFR 147.16 - Procedure for the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment).

    Science.gov (United States)

    2010-01-01

    ... mycoplasma reactors by in vivo bio-assay (enrichment). 147.16 Section 147.16 Animals and Animal Products... the evaluation of mycoplasma reactors by in vivo bio-assay (enrichment). This procedure has been shown... publications: (a) Bigland, C. H. and A. J. DaMassa, “A Bio-Assay for Mycoplasma Gallisepticum.” In: United...

  6. Development by flow cytometry of bioassays based on chlorella for environmental monitoring

    Directory of Open Access Journals (Sweden)

    Petrescu C-M,

    2016-05-01

    Full Text Available In ecotoxicological assessments, bioassays (ecotoxicity tests or biotests are one of the main tools, defined as methods which use living cells, tissues, organism or communities to assess exposure-related effects of chemicals. The increasing complexity of environmental degradation requires an increase in the capacity of scientific approach in monitoring and notification as early as possible risks. Our own objective concerns the detection of aquatic environment pollution in Romania and particularly in the Danube basin. For assessing aquatic environment pollution degree or for assessing cytotoxicity or ecotoxicity of pollutants (heavy metals, nanoparticles, pesticides, etc. we developed news experimental bioassays based on the use of viability and apoptosis biomarkers of Chlorella cells by flow cytometry. Our proposed bioassays could be rapid and very sensitive tests for in laboratory aquatic risk assessment and biomonitoring.

  7. HPLC ‘Multi-Analyte’ Detection Method

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticides carrying chromophoric structures by HPLC is described. Details are given on the materials and methods used. Recorded UV spectra of active substances are presented for allowing the verification of purity and the confirmation of substances eluting from the HPLC column. (author)

  8. A rapid and inexpensive bioassay to evaluate the decontamination of organophosphates.

    Science.gov (United States)

    Claborn, David M; Martin-Brown, Skylar A; Sagar, Sanjay Gupta; Durham, Paul

    2012-01-01

    An inexpensive and rapid bioassay using adult red flour beetles was developed for use in assessing the decontamination of environments containing organophosphates and related chemicals. A decontamination protocol was developed which demonstrated that 2 to 3 applications of 5% bleach solution were required to obtain nearly complete decontamination of malathion. The bioassay was also used to screen common household cleaners as potential decontaminating agents, but only 5% bleach was effective at improving survival of insects on steel plates treated with 25% malathion. A toxic degradation product (malaoxon) was detected using gas chromatography/mass spectrophotometry; this toxin affected the decontamination efficacy and resulted in continued toxicity to the beetles until subsequent decontaminations. The bioassay provides evidence to support the use of red flour beetles as a sensitive, less expensive method for determining safety levels of environments contaminated with malathion and other toxins, and may have application in the study of chemical warfare agents.

  9. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils.

    Science.gov (United States)

    Lors, Christine; Ponge, Jean-François; Martínez Aldaya, Maite; Damidot, Denis

    2010-08-01

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. Analysing traces of autoinducer-2 requires standardization of the Vibrio harveyi bioassay.

    Science.gov (United States)

    Vilchez, Ramiro; Lemme, André; Thiel, Verena; Schulz, Stefan; Sztajer, Helena; Wagner-Döbler, Irene

    2007-01-01

    Autoinducer-2 (furanosyl borate diester) is a biologically active compound whose role as a universal bacterial signalling molecule is currently under intense investigation. Because of its instability and the low concentrations of it found in biological samples, its detection relies at present on a bioassay that measures the difference in the timing of the luminescence of the Vibrio harveyi BB170 sensor strain with and without externally added AI-2. Here we systematically investigated which parameters affected the fold induction values of luminescence obtained in the bioassay and developed a modified protocol. Our experiments showed that growth and luminescence of V. harveyi BB170 are strongly influenced by trace elements. In particular, addition of Fe(3+) within a certain concentration range to the growth medium of the preinoculum culture improved the reproducibility and reduced the variance of the bioassay. In contrast, trace elements and vitamins introduced directly into the bioassay caused inhibitory effects. The initial density and luminescence of the sensor strain are very important and the values required for these parameters were defined. Borate interferes with the detection of AI-2 by giving false positive results. The response of V. harveyi BB170 to chemically synthesized AI-2 in the bioassay is nonlinear except over a very small concentration range; it is maximum over three orders of magnitude and shows inhibition above 35 microM. Based on the modified protocol, we were able to detect AI-2 in the absence of inhibitors with maximum fold induction values for the positive control (chemically synthesized AI-2) of >120 with a standard deviation of approximately 30% in a reliable and reproducible way.

  11. An examination of the analysis of radiostrontiums in bioassay applications

    International Nuclear Information System (INIS)

    Linauskas, S.H.; Leon, J.W.

    1993-05-01

    Radiostrontiums are among the most radiologically significant radionuclides in the nuclear reactor environment due to their relatively high fission yield, long physical half-life, volatility and mobility in the workplace, and long retention times in tissues such as bone. Effective bioassay programs include analytical processes that consider prospective monitoring requirements provided by screening measurements, as well as the retrospective monitoring requirements provided by screening measurements following an intake. Chromatography using crown ethers as well as the use of spectrometry techniques with advanced liquid-scintillation counters or solid-state surface-barrier detectors appear to have significant benefits for Sr bioassay programs. (author). 90 refs., 2 tabs., 3 figs

  12. An examination of the analysis of radiostrontiums in bioassay applications

    Energy Technology Data Exchange (ETDEWEB)

    Linauskas, S H; Leon, J W

    1993-05-01

    Radiostrontiums are among the most radiologically significant radionuclides in the nuclear reactor environment due to their relatively high fission yield, long physical half-life, volatility and mobility in the workplace, and long retention times in tissues such as bone. Effective bioassay programs include analytical processes that consider prospective monitoring requirements provided by screening measurements, as well as the retrospective monitoring requirements provided by screening measurements following an intake. Chromatography using crown ethers as well as the use of spectrometry techniques with advanced liquid-scintillation counters or solid-state surface-barrier detectors appear to have significant benefits for Sr bioassay programs. (author). 90 refs., 2 tabs., 3 figs.

  13. The IMBA suite: integrated modules for bioassay analysis

    Energy Technology Data Exchange (ETDEWEB)

    Birchall, A.; Jarvis, N.S.; Peace, M.S.; Riddell, A.E.; Battersby, W.P

    1998-07-01

    The increasing complexity of models representing the biokinetic behaviour of radionuclides in the body following intake poses problems for people who are required to implement these models. The problem is exacerbated by the current paucity of suitable software. In order to remedy this situation, a collaboration between British Nuclear Fuels, Westlakes Research Institute and the National Radiological Protection Board has started with the aim of producing a suite of modules for estimating intakes and doses from bioassay measurements using the new ICRP models. Each module will have a single purpose (e.g. to calculate respiratory tract deposition) and will interface with other software using data files. The elements to be implemented initially are plutonium, uranium, caesium, iodine and tritium. It is intended to make the software available to other parties under terms yet to be decided. This paper describes the proposed suite of integrated modules for bioassay analysis, IMBA. (author)

  14. Immuno-detection of cleaved SNAP-25 from differentiated mouse embryonic stem cells provides a sensitive assay for determination of botulinum A toxin and antitoxin potency.

    Science.gov (United States)

    Yadirgi, G; Stickings, P; Rajagopal, S; Liu, Y; Sesardic, D

    2017-12-01

    Botulinum toxin type A is a causative agent of human botulism. Due to high toxicity and ease of production it is classified by the Centres for Disease Control and Prevention as a category A bioterrorism agent. The same serotype, BoNT/A, is also the most widely used in pharmaceutical preparations for treatment of a diverse range of neuromuscular disorders. Traditionally, animals are used to confirm the presence and activity of toxin and to establish neutralizing capabilities of countermeasures in toxin neutralization tests. Cell based assays for BoNT/A have been reported as the most viable alternative to animal models, since they are capable of reflecting all key steps (binding, translocation, internalization and cleavage of intracellular substrate) involved in toxin activity. In this paper we report preliminary development of a simple immunochemical method for specifically detecting BoNT/A cleaved intracellular substrate, SNAP-25, in cell lysates of neurons derived from mouse embryonic stem cells. The assay offers sensitivity of better than 0.1LD50/ml (3fM) which is not matched by other functional assays, including the mouse bioassay, and provides serotype specificity for quantitative detection of BoNT/A and anti-BoNT/A antitoxin. Subject to formal validation, the method described here could potentially be used as a substitute for the mouse bioassay to measure potency and consistency of therapeutic products. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Expermental Studies of quantitative evaluation using HPLC

    Directory of Open Access Journals (Sweden)

    Ki Rok Kwon

    2005-06-01

    Full Text Available Methods : This study was conducted to carry out quantitative evaluation using HPLC Content analysis was done using HPLC Results : According to HPLC analysis, each BVA-1 contained approximately 0.36㎍ melittin, and BVA-2 contained approximately 0.54㎍ melittin. But the volume of coating was so minute, slight difference exists between each needle. Conclusion : Above results indicate that the bee venom acupuncture can complement shortcomings of syringe usage as a part of Oriental medicine treatment, but extensive researches should be done for further verification.

  16. A Bioassay System Using Bioelectric Signals from Small Fish

    Science.gov (United States)

    Terawaki, Mitsuru; Soh, Zu; Hirano, Akira; Tsuji, Toshio

    Although the quality of tap water is generally examined using chemical assay, this method cannot be used for examination in real time. Against such a background, the technique of fish bioassay has attracted attention as an approach that enables constant monitoring of aquatic contamination. The respiratory rhythms of fish are considered an efficient indicator for the ongoing assessment of water quality, since they are sensitive to chemicals and can be indirectly measured from bioelectric signals generated by breathing. In order to judge aquatic contamination accurately, it is necessary to measure bioelectric signals from fish swimming freely as well as to stably discriminate measured signals, which vary between individuals. However, no bioassay system meeting the above requirements has yet been established. This paper proposes a bioassay system using bioelectric signals generated from small fish in free-swimming conditions. The system records signals using multiple electrodes to cover the extensive measurement range required in a free-swimming environment, and automatically discriminates changes in water quality from signal frequency components. This discrimination is achieved through an ensemble classification method using probability neural networks to solve the problem of differences between individual fish. The paper also reports on the results of related validation experiments, which showed that the proposed system was able to stably discriminate between water conditions before and after bleach exposure.

  17. Methodology for estimation of 32P in bioassay samples by Cerenkov counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Yadav, R.K.B.; Rao, D.D.

    2016-01-01

    Radioactive phosphorus ( 32 P) as phosphate is used to effectively reduce bone pain in terminal cancer patients. Several hospitals in India carry out this palliative care procedure on a regular basis. Thus, production as well as synthesis of 32 P compounds has increased over the years to meet this requirement. Monitoring of radiation workers handling 32 P compounds is important for further strengthening of radiological protection program at processing facility. 32 P being a pure beta emitter (β max = 1.71 MeV, t 1/2 = 14.3 d), bioassay is the preferred individual monitoring technique. Method standardized at Bioassay Lab, Trombay, includes estimation of 32 P in urine by co-precipitation with ammonium phosphomolybdate (AMP) followed by gross beta counting. In the present study, feasibility of Cerenkov counting for detection of 32 P in bioassay samples was explored and the results obtained were compared with the gross beta counting technique

  18. In vitro bioassays for detecting dioxin-like activity--application potentials and limits of detection, a review.

    Science.gov (United States)

    Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner

    2014-07-15

    Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Development of androgen-and estrogen-responsive bioassays, members of a panel of human cell line-based highly selective steroid-responsive bioassays

    NARCIS (Netherlands)

    Sonneveld, E.; Jansen, H.J..; Riteco, J.A.C.; Brouwer, A.

    2005-01-01

    We have established highly sensitive and specific androgen and estrogen reporter cell lines which we have named AR (androgen receptor) and ERα (estrogen receptor alpha) CALUX® (Chemically Activated LUciferase eXpression), respectively. Both bioassays are member of a panel of CALUX reporter cell

  20. Fluorescence-based bioassays for the detection and evaluation of food materials.

    Science.gov (United States)

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-10-13

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR)-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA)-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials.

  1. Fluorescence-Based Bioassays for the Detection and Evaluation of Food Materials

    Directory of Open Access Journals (Sweden)

    Kentaro Nishi

    2015-10-01

    Full Text Available We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials.

  2. In Vitro Androgen Bioassays as a Detection Method for Designer Androgens

    Directory of Open Access Journals (Sweden)

    Alison K. Heather

    2013-02-01

    Full Text Available Androgens are the class of sex steroids responsible for male sexual characteristics, including increased muscle mass and decreased fat mass. Illicit use of androgen doping can be an attractive option for those looking to enhance sporting performance and/or physical appearance. The use of in vitro bioassays to detect androgens, especially designer or proandrogens, is becoming increasingly important in combating androgen doping associated with nutritional supplements. The nutritional sports supplement market has grown rapidly throughout the past decade. Many of these supplements contain androgens, designer androgens or proandrogens. Many designer or proandrogens cannot be detected by the standard highly-sensitive screening methods such as gas chromatography-mass spectrometry because their chemical structure is unknown. However, in vitro androgen bioassays can detect designer and proandrogens as these assays are not reliant on knowing the chemical structure but instead are based on androgen receptor activation. For these reasons, it may be advantageous to use routine androgen bioassay screening of nutraceutical samples to help curb the increasing problem of androgen doping.

  3. Sensitive measurement of positron emitters eluted from HPLC

    International Nuclear Information System (INIS)

    Takei, Makoto; Kida, Takayo; Suzuki, Kazutoshi

    2001-01-01

    For sensitive analysis of the radioactive-metabolite in human PET, a radio-HPLC system coupled to a newly designed positron detector was constructed. The detector had the advantages of low noise level (1.7±1.0 cpm) and high sensitivity (32±1%) due to coincidence counting and large BGO crystals. Furthermore, the detector was easy to move, since a pair of the BGO housings coupled to photomultipliers was effectively arranged in parallel and a HPLC cell with different volume could be inserted between the BGO housing. This radio-HPLC system was useful for analyzing samples with low radioactivity. It was applied to the measurement of [ 11 C]FLB457 in plasma, having high affinity and high selectivity with dopamine D2 receptors. Extremely low radioactivity of [ 11 C]FLB457 (2500 dpm) could be analyzed by using the radio-HPLC system. The performance of this detector was compared with those of commercially available systems that had been used as sensitive detectors for HPLC

  4. Development of K-bioassay for the efficient potassium fertilization of citrus tree

    Energy Technology Data Exchange (ETDEWEB)

    U, Jang Kual [Cheju National University, Cheju (Korea, Republic of); Han, Hae Ryong [Cheju National University, Cheju (Korea, Republic of); Moon, Duk Young; Kim, Chang Myung; Lim, Han Cheol; Moon, Do Kyung [Cheju Citrus Research Institute, Cheju (Korea, Republic of); Song, Sung Jun [Cheju National Univerisity, Cheju (Korea, Republic of)

    1994-12-31

    a Similar to the {sup 42} K uptake, {sup 86} Rb uptake by the roots of Hordeum distichum grown in the hydroponic culture was negatively correlated with the concentration of K supplied previously, showing that {sup 86} Rb can be used for the K-bioassay. {sup 86} Rb having longer half life(18.86 day) than {sup 42} K(12.36 hr) allowed the use of larger number of root samples. {sup 86} Rb uptake of 3 years old Citrus unshiu Marc. grown in water culture decreased drastically with the increase of K concentration of the culture solution, thus demonstrating that the nutrition status of K for citrus trees can be diagnosed by K-bioassay using {sup 86} Rb tracer. {sup 86} Rb uptake by the excised roots of Hordeum distichum correlated with the exchangeable K in soil. The amount of exchangeable K in soil for the optimal plant growth can be determined by its relationship. {sup 42} K- and {sup 86} Rb-uptake by the Hordeum distichum roots were markedly inhibited by 5 x 10{sup -3} M KCN in the bioassay solution, indicating that uptake is metabolically controlled. There was no significant relationship between K content in citrus leaves and K concentration in the water-culture medium. It is concluded that K-bioassay is a potentially useful tool for determining of K requirement in citrus trees. (author)

  5. 'Dose per unit content' functions: A robust tool for the interpretation of bioassay data

    International Nuclear Information System (INIS)

    Berkovski, V.; Bonchuk, Y.; Ratia, G.

    2003-01-01

    The purposes of this study were to investigate the influence of the consequences of the lack of primary bioassay information and to elaborate approaches which could improve the reliability of dose assessments. The aggregated time-dependent functions 'dose per unit organ (excretion) content' z(t) have been proposed in this study as a convenient and reliable tool for bioassay. The analysis of the variation of z with changes of AMAD has demonstrated the existence of areas of the relative invariance of z, which permits the selection of one (reference) function z for the whole area of stability. Within the framework of such an approach an arbitrary set of bioassay data can be approximated by the linear combination F(t) S i E/ i z(t-t i ), whereI> F(t) function of time t, which approximates the observed bioassay time trend; t i = time shift of the acute intake i; E i effective dose, associated with the acute intake i (the two last parameters are results of the approximation procedure). (author)

  6. HPLC-ESR techniques for detection of complex trapped radicals

    International Nuclear Information System (INIS)

    Tu Tiecheng; Dong Jirong; Lin Nianyun; Xie Leidong; Liu Rengzhong

    1992-01-01

    High performance liquid chromatography (HPLC) and ESR combined examination of radical species is an advanced techniques for separation and identification of complex radical species. At SRCL, Waters 990 HPLC has been used to separate the complex trapped radicals and Varian E-112 ESR spectrometer to record the spectra of single trapped radicals after HPLC separation. The advantages of the combined techniques are described as bellow: HPLC is used to separate the long-lived complex trapped radicals derived from reaction of short-lived radicals with spin trap. ESR spectra from single trapped radicals, obtained following HPLC separation of complex trapped radicals, are recorded one by one and well resolved. The structures of short-lived radicals can be inferred from the ESR spectra of the long-lived trapped radicals

  7. Hierarchical responses to organic contaminants in aquatic ecotoxicological bioassays: from microcystins to biodegradation

    OpenAIRE

    Montenegro, Katia

    2008-01-01

    In this thesis I explore the ecotoxicological responses of aquatic organisms at different hierarchical levels to organic contaminants by means of bioassays. The bioassays use novel endpoints or approaches to elucidate the effects of exposure to contaminants and attempt to give mechanistic explanations that could be used to interpret effects at higher hierarchical scales. The sensitivity of population growth rate in the cyanobacteria species Microcystis aeruginosa to the herbicide glyp...

  8. Issues in weighting bioassay data for use in regressions for internal dose assessments

    International Nuclear Information System (INIS)

    Strom, D.J.

    1992-11-01

    For use of bioassay data in internal dose assessment, research should be done to clarify the goal desired, the choice of method to achieve the goal, the selection of adjustable parameters, and on the ensemble of information that is available. Understanding of these issues should determine choices of weighting factors for bioassay data used in regression models. This paper provides an assessment of the relative importance of the various factors

  9. Changes in chemical composition and bioassay assessment of ...

    African Journals Online (AJOL)

    Changes in chemical composition and bioassay assessment of nutritional potentials of almond fruit waste as an alternative feedstuff for livestock. ... AFW using day-old cockerels and considering performance parameters showed that treated AFW improved feed intake, body weight gain and feed conversion ratio even better ...

  10. Chemical fingerprinting and quantitative analysis of a Panax notoginseng preparation using HPLC-UV and HPLC-MS

    Directory of Open Access Journals (Sweden)

    Shao Qing

    2011-02-01

    Full Text Available Abstract Background Xuesaitong (XST injection, consisting of total saponins from Panax notoginseng, was widely used for the treatment of cardio- and cerebro-vascular diseases in China. This study develops a simple and global quality evaluation method for the quality control of XST. Methods High performance liquid chromatography-ultraviolet detection (HPLC-UV was used to identify and quantify the chromatographic fingerprints of the XST injection. Characteristic common peaks were identified using HPLC with photo diode array detection/electrospray ionization tandem mass spectrometry (HPLC-PDA/ESI-MSn. Results Representative fingerprints from ten batches of samples showed 27 'common saponins' all of which were identified and quantified using ten reference saponins. Conclusion Chemical fingerprinting and quantitative analysis identified most of the common saponins for the quality control of P. notoginseng products such as the XST injection.

  11. The use of cultivars of Raphanus sativus for cytokinin bioassay

    Directory of Open Access Journals (Sweden)

    Dorota Kubowicz

    2013-12-01

    Full Text Available Six cultivars of radish (Raphanus sativus were tested for their usefulness in radish cytokinin bioassay by the method of Letham (1971. The best cultivar was found to be 'Sopel Lodu' which responds well to both zeatin and 2iP over a wide range of concentrations. The fresh weight of cotyledons increased at most by 71.5% (if treated with zeatin or 101.0% (if treated with 2iP compared to untreated cotyledons. This cultivar is also sensitive to the partially purified cytokinin-like fraction isolated from the pine (Pinus silvestris cambial region. The cultivar 'Sopel Lodu' is therefore proposed to be a suitable plant for cytokinin bioassays.

  12. [Investigation on pattern of quality control for Chinese materia medica based on famous-region drug and bioassay--the work reference].

    Science.gov (United States)

    Yan, Dan; Xiao, Xiaohe

    2011-05-01

    Selection and standardization of the work reference are the technical issues to be faced with in the bioassay of Chinese materia medica. Taking the bioassay of Coptis chinensis. as an example, the manufacture process of the famous-region drugs extraction was explained from the aspects of original identification, routine examination, component analysis and bioassay. The common technologies were extracted, and the selection and standardization procedures of the work reference for the bioassay of Chinese materia medica were drawn up, so as to provide technical support for constructing a new mode and method of the quality control of Chinese materia medica based on the famous-region drugs and bioassay.

  13. Natural products phytotoxicity A bioassay suitable for small quantities of slightly water-soluble compounds.

    Science.gov (United States)

    Dornbos, D L; Spencer, G F

    1990-02-01

    A large variety of secondary metabolites that can inhibit germination and/or seedling growth are produced by plants in low quantities. The objective of this study was to develop a bioassay capable of reliably assessing reductions in germination percentage and seedling length of small-seeded plant species caused by exposure to minute quantities of these compounds. The germination and growth of alfalfa (Medicago saliva), annual ryegrass (Lolium multiflorum), and velvetleaf (Abutilon theophrasti) were evaluated against six known phytotoxins from five chemical classes; cinmethylin (a herbicidal cineole derivative) was selected as a comparison standard. Each phytotoxin, dissolved in a suitable organic solvent, was placed on water-agar in small tissue culture wells. After the solvent evaporated, imbibed seeds were placed on the agar; after three days, germination percentages and seedling lengths were measured. Compared to a commonly used filter paper procedure, this modified agar bioassay required smaller quantities of compound per seed for comparable bioassay results. This bioassay also readily permitted the measurement of seedling length, a more sensitive indicator of phytotoxicity than germination. Seedling length decreased sigmoidally as the toxin concentration increased logarithmically. Phytotoxicity was a function of both compound and plant species. Cinmethylin, a grass herbicide, reduced the length of annual ryegrass seedlings by 90-100%, whereas that of alfalfa and velvetleaf was inhibited slightly. The agar bioassay facilitated the rapid and reliable testing of slightly water-soluble compounds, requiring only minute quantities of each compound to give reproducible results.

  14. The Intersection of CMOS Microsystems and Upconversion Nanoparticles for Luminescence Bioimaging and Bioassays

    Directory of Open Access Journals (Sweden)

    Liping Wei

    2014-09-01

    Full Text Available Organic fluorophores and quantum dots are ubiquitous as contrast agents for bio-imaging and as labels in bioassays to enable the detection of biological targets and processes. Upconversion nanoparticles (UCNPs offer a different set of opportunities as labels in bioassays and for bioimaging. UCNPs are excited at near-infrared (NIR wavelengths where biological molecules are optically transparent, and their luminesce in the visible and ultraviolet (UV wavelength range is suitable for detection using complementary metal-oxide-semiconductor (CMOS technology. These nanoparticles provide multiple sharp emission bands, long lifetimes, tunable emission, high photostability, and low cytotoxicity, which render them particularly useful for bio-imaging applications and multiplexed bioassays. This paper surveys several key concepts surrounding upconversion nanoparticles and the systems that detect and process the corresponding luminescence signals. The principle of photon upconversion, tuning of emission wavelengths, UCNP bioassays, and UCNP time-resolved techniques are described. Electronic readout systems for signal detection and processing suitable for UCNP luminescence using CMOS technology are discussed. This includes recent progress in miniaturized detectors, integrated spectral sensing, and high-precision time-domain circuits. Emphasis is placed on the physical attributes of UCNPs that map strongly to the technical features that CMOS devices excel in delivering, exploring the interoperability between the two technologies.

  15. Development of Androgen- and Estrogen-Responsive bio-assays, members of a panel of human cell line-based highly selective steroid-responsive bioassays

    NARCIS (Netherlands)

    Sonneveld, E.; Jansen, H.J.

    2004-01-01

    We have established highly sensitive and specific androgen and estrogen reporter cell lines which we have named AR (androgen receptor) and ERα (estrogen receptor alpha) CALUX® (Chemically Activated LUciferase eXpression), respectively. Both bioassays are member of a panel of CALUX reporter cell

  16. Particle size fractionation of paralytic shellfish toxins (PSTs): seasonal distribution and bacterial production in the St Lawrence estuary, Canada.

    Science.gov (United States)

    Michaud, S; Levasseur, M; Doucette, G; Cantin, G

    2002-10-01

    We determined the seasonal distribution of paralytic shellfish toxins (PSTs) and PST producing bacteria in > 15, 5-15, and 0.22-5 microm size fractions in the St Lawrence. We also measured PSTs in a local population of Mytilus edulis. PST concentrations were determined in each size fraction and in laboratory incubations of sub-samples by high performance liquid chromatography (HPLC), including the rigorous elimination of suspected toxin 'imposter' peaks. Mussel toxin levels were determined by mouse bioassay and HPLC. PSTs were detected in all size fractions during the summer sampling season, with 47% of the water column toxin levels associated with particles smaller than Alexandrium tamarense ( 15 microm size fraction, we estimated that as much as 92% of PSTs could be associated with particles other than A. tamarense. Our results stress the importance of taking into account the potential presence of PSTs in size fractions other than that containing the known algal producer when attempting to model shellfish intoxication, especially during years of low cell abundance. Finally, our HPLC results confirmed the presence of bacteria capable of autonomous PST production in the St Lawrence as well as demonstrating their regular presence and apparent diversity in the plankton. Copyright 2002 Elsevier Science Ltd.

  17. Bioassay-Guided Isolation of Neuroprotective Compounds from Uncaria rhynchophylla against Beta-Amyloid-Induced Neurotoxicity.

    Science.gov (United States)

    Xian, Yan-Fang; Lin, Zhi-Xiu; Mao, Qing-Qiu; Hu, Zhen; Zhao, Ming; Che, Chun-Tao; Ip, Siu-Po

    2012-01-01

    Uncaria rhynchophylla is a component herb of many Chinese herbal formulae for the treatment of neurodegenerative diseases. Previous study in our laboratory has demonstrated that an ethanol extract of Uncaria rhynchophylla ameliorated cognitive deficits in a mouse model of Alzheimer's disease induced by D-galactose. However, the active ingredients of Uncaria rhynchophylla responsible for the anti-Alzheimer's disease activity have not been identified. This study aims to identify the active ingredients of Uncaria rhynchophylla by a bioassay-guided fractionation approach and explore the acting mechanism of these active ingredients by using a well-established cellular model of Alzheimer's disease, beta-amyloid- (Aβ-) induced neurotoxicity in PC12 cells. The results showed that six alkaloids, namely, corynoxine, corynoxine B, corynoxeine, isorhynchophylline, isocorynoxeine, and rhynchophylline were isolated from the extract of Uncaria rhynchophylla. Among them, rhynchophylline and isorhynchophylline significantly decreased Aβ-induced cell death, intracellular calcium overloading, and tau protein hyperphosphorylation in PC12 cells. These results suggest that rhynchophylline and isorhynchophylline are the major active ingredients responsible for the protective action of Uncaria rhynchophylla against Aβ-induced neuronal toxicity, and their neuroprotective effect may be mediated, at least in part, by inhibiting intracellular calcium overloading and tau protein hyperphosphorylation.

  18. Toxicity of hydrogen sulfide to goldfish (Carassius auratus L. ) as influenced by temperature, oxygen, and bioassay techniques

    Energy Technology Data Exchange (ETDEWEB)

    Adelman, I.R.; Smith, L.L. Jr.

    1972-01-01

    Bioassays were conducted to test the effect of temperature and oxygen on H/sub 2/S toxicity to goldfish (Carassius auratus L.) and to investigate some factors that influence bioassay results. Relation of H/sub 2/S toxicity to temperature is negatively logarithmic over the range of 6.5-25 C. The mean 96-hr TL50 at 6 C was 530 ..mu..g/liter and at 25 C was 4 ..mu..g/liter. At temperatures of 14, 20, and 26 C, most acute mortality from H/sub 2/S ended by 11 days and the 11-day TL50's at these temperatures were significantly different. In bioassays with and without prior oxygen acclimation, decreasing oxygen concentrations increased H/sub 2/S toxicity. In the former, mean TL50's were 62 and 48 ..mu..g/liter H/sub 2/S at oxygen concentrations of 6 and 1.5 mg/liter, respectively, and in the latter, 71 and 53 ..mu..g/liter H/sub 2/S at the same oxygen concentrations. Variability in bioassay results was not affected by test temperatures of 14, 20, and 26 C, and in most cases 1 week of temperature acclimation was adequate. Stocks of fish responded differently after 11 days of bioassay, although differences were not detected after 4 days of bioassay. 27 references, 4 figures, 3 tables.

  19. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  20. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  1. The application of bioassays as indicators of petroleum-contaminated soil remediation.

    Science.gov (United States)

    Płaza, Grazyna; Nałecz-Jawecki, Grzegorz; Ulfig, Krzysztof; Brigmon, Robin L

    2005-04-01

    Bioremediation has proven successful in numerous applications to petroleum contaminated soils. However, questions remain as to the efficiency of bioremediation in lowering long-term soil toxicity. In the present study, the bioassays Spirotox, Microtox, Ostracodtoxkit F, umu-test with S-9 activation, and plant assays were applied, and compared to evaluate bioremediation processes in heavily petroleum contaminated soils. Six higher plant species (Secale cereale L., Lactuca sativa L., Zea mays L., Lepidium sativum L., Triticum vulgare L., Brassica oleracea L.) were used for bioassay tests based on seed germination and root elongation. The ecotoxicological analyses were made in DMSO/H2O and DCM/DMSO soil extracts. Soils were tested from two biopiles at the Czechowice oil refinery, Poland, that have been subjected to different bioremediation applications. In biopile 1 the active or engineered bioremediation process lasted four years, while biopile 2 was treated passively or non-engineered for eight months. The test species demonstrated varying sensitivity to soils from both biopiles. The effects on test organisms exposed to biopile 2 soils were several times higher compared to those in biopile 1 soils, which correlated with the soil contaminants concentration. Soil hydrocarbon concentrations indeed decreased an average of 81% in biopile 1, whereas in biopile 2 TPH/TPOC concentrations only decreased by 30% after eight months of bioremediation. The bioassays were presented to be sensitive indicators of soil quality and can be used to evaluate the quality of bioremediated soil. The study encourages the need to combine the bioassays with chemical monitoring for evaluation of the bioremediation effectiveness and assessing of the contaminated/remediated soils.

  2. Methods and applications of HPLC-AMS

    International Nuclear Information System (INIS)

    Buchholz, Bruce A.; Dueker, Stephen R.; Lin, Yumei; Clifford, Andrew J.; Vogel, John S.

    2000-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a 14 C-labeled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the 14 C content above the control predose tissue and converting to equivalents of the parent compound. High performance liquid chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are tentatively identified by co-elution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the 14 C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of 14 C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected 14 C activity <0.17 Bq (4.5 pCi) on the HPLC column

  3. Resolutions of ICRP models with BIOKMOD: Application for the bioassays evaluation

    International Nuclear Information System (INIS)

    Sanchez, G.

    2005-01-01

    Biokmod is a tool box developed using Mathematic for solving compartmental modes. It gives analytic and numeric solutions. Biokmod solves the current ICRP models including Acute, constant, continuous variable, multi-inputs and random intakes. All parameters (deposition factors, rate transfer coefficients, fractional rate of absorption, etc.) can be modified by users. It can be also applied for evaluating unknown intakes fitting bioassay experimental data and for evacuating uncertainties in the ICRP models. There is a web version (BiokmodWeb) at http://www3.enusa.es//webMathematica/public/biokmode.html. In this article we describe the application of Biokmod for evaluating Bioassays. (Author) 8 refs

  4. Requirements for radiation emergency urine bioassay techniques for the public and first responders.

    Science.gov (United States)

    Li, Chunsheng; Vlahovich, Slavica; Dai, Xiongxin; Richardson, Richard B; Daka, Joseph N; Kramer, Gary H

    2010-11-01

    Following a radiation emergency, the affected public and the first responders may need to be quickly assessed for internal contamination by the radionuclides involved. Urine bioassay is one of the most commonly used methods for assessing radionuclide intake and radiation dose. This paper attempts to derive the sensitivity requirements (from inhalation exposure) for the urine bioassay techniques for the top 10 high-risk radionuclides that might be used in a terrorist attack. The requirements are based on a proposed reference dose to adults of 0.1 Sv (CED, committed effective dose). In addition, requirements related to sample turnaround time and field deployability of the assay techniques are also discussed. A review of currently available assay techniques summarized in this paper reveals that method development for ²⁴¹Am, ²²⁶Ra, ²³⁸Pu, and ⁹⁰Sr urine bioassay is needed.

  5. Quality Control of Selected Pesticides with HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Karasali, H. [Benaki Phytopathological Institute Laboratory of Physical and Chemical Analysis of Pesticides, Ekalis (Greece)

    2009-07-15

    Laboratory data obtained on two different HPLC separation columns and detection by UV and DAD under repeatability conditions are presented and discussed. The behaviour of pesticides on different HPLC columns under gradient and isocratic conditions is evaluated concerning the applicability of respective methodologies. Representative chromatograms of real formulations and “empty” formlants are given for illustration. (author)

  6. Responses of lone star tick (acari: ixodidae) nymphs to the repellent deet applied in acetone and ethanol solutions in vitro bioassays

    Science.gov (United States)

    Behavioral bioassays remain a standard tool in the discovery, development, and registration of repellents. Although tick repellent bioassays tend to be rather uncomplicated, several factors can influence their outcomes. Typically repellent bioassays use a solvent, such as acetone or ethanol, to disp...

  7. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  8. Progress in herbicide determination with the thylakoid bioassay.

    Science.gov (United States)

    Trapmann, S; Etxebarria, N; Schnabl, H; Grobecker, K H

    1998-01-01

    Chloroplast thylakoids are used as biological units to determine herbicides in different kinds of water samples as well as in aqueous extracts of compost, soil or food samples. The thylakoid bioassay shows clearly inhibition of fluorescence yield in the presence of photosystem II specific herbicides. Due to this method the ecotoxicological effect of samples with unknown pollutants can be tested fast and cost effective. It has been proven that all photosynthetic active compounds are recorded at the same time because only additive interactions occur. Therefore, the contamination level can be expressed as cumulative parameter for photosystem II active substances. Application was improved clearly by the addition of the radical scavenger sodium ascorbate to the isolation media and by a higher concentration of the measuring medium. A new data evaluation method is described yielding in a lower detection limit of 0.4 microg diuron/1. The guidelines for the quality of water for human consumption with an allowable concentration of pesticides in groups is 0,5 microg/1 and can be controlled with the thylakoid bioassay without performing any preconcentration steps.

  9. Androgen Bioassay for the Detection of Nonlabeled Androgenic Compounds in Nutritional Supplements.

    Science.gov (United States)

    Cooper, Elliot R; McGrath, Kristine C Y; Li, XiaoHong; Heather, Alison K

    2018-01-01

    Both athletes and the general population use nutritional supplements. Athletes often turn to supplements hoping that consuming the supplement will help them be more competitive and healthy, while the general population hopes to improve body image or vitality. While many supplements contain ingredients that may have useful properties, there are supplements that are contaminated with compounds that are banned for use in sport or have been deliberately adulterated to fortify a supplement with an ingredient that will produce the advertised effect. In the present study, we have used yeast cell and mammalian cell androgen bioassays to characterize the androgenic bioactivity of 112 sports supplements available from the Australian market, either over the counter or via the Internet. All 112 products did not declare an androgen on the label as an included ingredient. Our findings show that six out of 112 supplements had strong androgenic bioactivity in the yeast cell bioassay, indicating products spiked or contaminated with androgens. The mammalian cell bioassay confirmed the strong androgenic bioactivity of five out of six positive supplements. Supplement 6 was metabolized to weaker androgenic bioactivity in the mammalian cells. Further to this, Supplement 6 was positive in a yeast cell progestin bioassay. Together, these findings highlight that nutritional supplements, taken without medical supervision, could expose or predispose users to the adverse consequences of androgen abuse. The findings reinforce the need to increase awareness of the dangers of nutritional supplements and highlight the challenges that clinicians face in the fast-growing market of nutritional supplements.

  10. Photoeffects of near ultraviolet light upon a polycyclic aromatic hydrocarbon exposed to mouse skin microsomes

    International Nuclear Information System (INIS)

    Peirano, W.B.

    1991-01-01

    Near ultraviolet (UV) light has been reported to both enhance and inhibit the tumor incidence in mice dermally exposed to benzo(a)pyrene (BaP) or polycyclic aromatic hydrocarbon (PAH) mixtures. Near UV light interacts with PAHs producing a variety of oxygenated products such as phenols, endoperoxides and quinones. However, little is known about BaP products formed from near UV irradiation of BaP-exposed mouse skin. Therefore, 14 C-BaP was incubated with 3-methylcholanthrene (3-MC) induced C 3 H/HeJ and DBA/2J mouse skin microsomes with or without a 365 nm light source. The results indicated that the concurrent 365 nm light irradiation of induced mouse skin microsomes and BaP greatly enhanced the total conversion of BaP to its products, approximately 3-fold for the C 3 H/HeJ and approximately 7-fold for the DBA/2J mouse microsomes, compared to the induced mouse skin microsomes and BaP alone. HPLC analyses of organic extracts indicated a more than additive enhancement of the formation of most of the individual cochromatographed BaP metabolites due to the combined interaction of 365 nm light with BaP and skin microsomes. Similar interactions were observed using benz(a)anthracene (BaA) in this system. These data show that near UV light alters the metabolic profile of PAHs produced by mouse skin microsomes

  11. Application of the CALUX bioassay for epidemiological study. Analyses of Belgian human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Wouwe, N. van; Debacker, N.; Sasse, A. [Scientific Institute of Public Health, Brussels (BE)] (and others)

    2004-09-15

    The CALUX bioassay is a promising screening method for the detection of dioxin-like compounds. The observed good sensitivity, low number of false negative results as well as the good correlations with the GC-HRMS TEQ-values in case of feed and food analyses allow this method to climb in the first assessment methods' scale. The low amount of sample needed in addition to those latest advantages suggest that the CALUX bioassay could be a good screening method for epidemiological studies. The Belgian epidemiological study concerning the possible effect of the dioxin incident on the body burden of the Belgian population was an opportunity to test this method in comparison to the gold reference one: the GC-HRMS. The first part of this abstract presents epidemiological parameters (sensibility, specificity,) of the CALUX bioassay using CALUX TEQ-values as estimators of the TEQ-values of the 17 PCDD/Fs. The second part examines epidemiological determinants observed for CALUX and GCHRMS TEQ-values.

  12. Assessing the genotoxicity of urban air pollutants using two in situ plant bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Villarini, M.; Fatigoni, C.; Dominici, L.; Maestri, S. [Department of Medical-Surgical Specialties and Public Health, University of Perugia, I-06126 (Italy); Ederli, L.; Pasqualini, S. [Department of Applied Biology, University of Perugia, I-06121 (Italy); Monarca, S. [Department of Medical-Surgical Specialties and Public Health, University of Perugia, I-06126 (Italy); Moretti, M., E-mail: massimo.moretti@unipg.i [Department of Medical-Surgical Specialties and Public Health, University of Perugia, I-06126 (Italy)

    2009-12-15

    Genotoxicity of urban air has been analysed almost exclusively in airborne particulates. We monitored the genotoxic effects of airborne pollutants in the urban air of Perugia (Central Italy). Two plant bioindicators with different genetic endpoints were used: micronuclei in meiotic pollen mother cells using Tradescantia-micronucleus bioassay (Trad-MCN) and DNA damage in nuclei of Nicotiana tabacum leaves using comet assay (Nicotiana-comet). Buds of Tradescantia clone no. 4430 and young N. tabacum cv. Xanthi plants were exposed for 24 h at three sites with different pollution levels. One control site (indoor control) was also used. The two bioassays showed different sensitivities toward urban pollutants: Trad-MCN assay was the most sensitive, but DNA damage in N. tabacum showed a better correlation with the pollutant concentrations. In situ biomonitoring of airborne genotoxins using higher plants combined with chemical analysis is thus recommended for characterizing genotoxicity of urban air. - Plant bioassays used to explore in situ the correlation between air pollution and genotoxicity.

  13. Assessing the genotoxicity of urban air pollutants using two in situ plant bioassays

    International Nuclear Information System (INIS)

    Villarini, M.; Fatigoni, C.; Dominici, L.; Maestri, S.; Ederli, L.; Pasqualini, S.; Monarca, S.; Moretti, M.

    2009-01-01

    Genotoxicity of urban air has been analysed almost exclusively in airborne particulates. We monitored the genotoxic effects of airborne pollutants in the urban air of Perugia (Central Italy). Two plant bioindicators with different genetic endpoints were used: micronuclei in meiotic pollen mother cells using Tradescantia-micronucleus bioassay (Trad-MCN) and DNA damage in nuclei of Nicotiana tabacum leaves using comet assay (Nicotiana-comet). Buds of Tradescantia clone no. 4430 and young N. tabacum cv. Xanthi plants were exposed for 24 h at three sites with different pollution levels. One control site (indoor control) was also used. The two bioassays showed different sensitivities toward urban pollutants: Trad-MCN assay was the most sensitive, but DNA damage in N. tabacum showed a better correlation with the pollutant concentrations. In situ biomonitoring of airborne genotoxins using higher plants combined with chemical analysis is thus recommended for characterizing genotoxicity of urban air. - Plant bioassays used to explore in situ the correlation between air pollution and genotoxicity.

  14. Impact of Spodoptera frugiperda neonate pretreatment conditions on Vip3Aa19 insecticidal protein activity and laboratory bioassay variation.

    Science.gov (United States)

    Da Silva, Karen F; Spencer, Terence A; Camargo Gil, Carolina; Siegfried, Blair D; Walters, Frederick S

    2016-04-01

    Variation in response to insecticidal proteins is common upon repetition of insect bioassays. Understanding this variation is a prerequisite to detecting biologically important differences. We tracked neonate Spodoptera frugiperda (J.E. Smith) susceptibility to Vip3Aa19 over 17 generations using standardized bioassay methods. Five larval pretreatment conditions and one bioassay condition were tested to determine whether susceptibility was affected. These included: storage time; prefeeding; storage at reduced temperature; storage at reduced humidity; colony introgression of field-collected individuals. Extremes of photoperiod during the bioassay itself were also examined. LC50 values for two strains of S. frugiperda varied 6.6-fold or 8.8-fold over 17 generations. Storage time and humidity had no impact on Vip3Aa19 susceptibility, whereas prefeeding significantly reduced subsequent mortality (by 27%). Storage at reduced temperature increased mortality for one colony (from 45.6 to 73.0%) but not for the other. Introgression of field-collected individuals affected susceptibility at the first generation but not for subsequent generations. A 24 h bioassay photophase significantly reduced susceptibility (by 26%) for both colonies. Certain pretreatment and bioassay conditions were identified that can affect S. frugiperda Vip3Aa19 susceptibility, but innate larval heterogeneity was also present. Our observations should help to increase the consistency of insecticidal protein bioassay results. © 2015 Syngenta Crop Protection, LLC. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

  15. [Studies on HPLC-FPS of the saponins from Semen Ziziphi Spinosae].

    Science.gov (United States)

    Wu, He-zhen; Chen, Jing; Liu, Yan-wen

    2006-09-01

    To establish a method of HPLC-fingerprint spectrum (HPLC-FPS) for the active part in Semen Ziziphi Spinosae (SZS) in order to control the quality of SZS from different places. The gradient elution mode was applied in chromatographic separation, and data were analysed by" Similarity Evaluation software" to compare the HPLC-FPS of SZS from different places. The conditions for HPLC analysis of SZS were established and the FPS of samples from different habitats showed some differences. All components in the spectrum were separated well and the HPLC fingerprint method is repeatable. The method can be used in quality assessment of SZS.

  16. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    Science.gov (United States)

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  17. Development of bacteria-based bioassays for arsenic detection in natural waters.

    Science.gov (United States)

    Diesel, Elizabeth; Schreiber, Madeline; van der Meer, Jan Roelof

    2009-06-01

    Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams.

  18. Development of bacteria-based bioassays for arsenic detection in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Diesel, Elizabeth; Schreiber, Madeline [Virginia Tech, Department of Geosciences, Blacksburg, VA (United States); Meer, Jan Roelof van der [University of Lausanne, Department of Fundamental Microbiology, Lausanne (Switzerland)

    2009-06-15

    Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams. (orig.)

  19. Bioassay of procoagulant albumin in human plasma.

    Science.gov (United States)

    Grosset, A; Liu, L; Parker, C J; Rodgers, G M

    1994-09-01

    Procoagulant albumin (P-Al) is present in normal human plasma and increases monocyte and endothelial cell expression of tissue factor activity. To develop a bioassay for P-Al, we partially purified plasma from healthy volunteers and several patient groups using BaCl2 and (NH4)2SO4 precipitation. The samples were assayed for tissue factor (TF) inducing activity, expressed as a percentage increase compared to a serum-free media control. Over six months, the assay was reproducible in stored samples and in serial samples from normal volunteers. The plasma P-Al activities of 35 volunteers averaged 141 +/- 8.2% (SEM). There was no diurnal variation. There was no difference in the P-Al activity after a 12 hour fast and 2 hours after a large meal in 4 healthy volunteers. There was no increase in activity (r = 0.16) with the subject's age. The average activity from 16 poorly-controlled diabetics was 131 +/- 11% (SEM). No alteration in activity was seen with samples from patients with uremia, liver dysfunction, hemophilia, thrombotic events, or adenocarcinoma. These results indicate that P-Al activity can be bioassayed in individual patient samples; however, pathologic states associated with abnormal P-Al-induced tissue factor activity presently remain unidentified.

  20. A Rapid and Simple Bioassay Method for Herbicide Detection

    Directory of Open Access Journals (Sweden)

    Xiu-Qing Li

    2008-01-01

    Full Text Available Chlamydomonas reinhardtii, a unicellular green alga, has been used in bioassay detection of a variety of toxic compounds such as pesticides and toxic metals, but mainly using liquid culture systems. In this study, an algal lawn--agar system for semi-quantitative bioassay of herbicidal activities has been developed. Sixteen different herbicides belonging to 11 different categories were applied to paper disks and placed on green alga lawns in Petri dishes. Presence of herbicide activities was indicated by clearing zones around the paper disks on the lawn 2-3 days after application. The different groups of herbicides induced clearing zones of variable size that depended on the amount, mode of action, and chemical properties of the herbicides applied to the paper disks. This simple, paper-disk-algal system may be used to detect the presence of herbicides in water samples and act as a quick and inexpensive semi-quantitative screening for assessing herbicide contamination.

  1. Effect of the Changes of Respiratory Tract Model on the Uranium Bioassay Data

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Taeeun; Noh, Siwan; Kim, Meeryeong; Lee, Jaiki [Hanyang Univ., Seoul (Korea, Republic of); Lee, Jongil; Kim, Jang Lyul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The HRTM, however, was revised based on the recent experimental data in OIR (Occupational Intakes of Radionuclides) draft report of ICRP. The changes of respiratory tract model are predicted to directly affect bioassay data like retention and excretion functions. Lung retention function is especially important to internal exposure assessment for workers related to fuel manufacturing because the place could be contaminated by uranium. In addition, faecel samples are recommended to be used for in-vitro bioassay of uranium because of very slow excretion via urine. More reliable assessments for the workers in fuel manufacturing could be achieved by recalculation of bioassay data for uranium and the comparing study using original and revised HRTM. In this study, therefore, the lung retention and faecal excretion functions for inhalation of UO{sub 2} and U{sub 3}O{sub 8} were recalculated using revised HRTM and the results were compared with those of original HRTM. In this study the lung retention and faecal excretion functions for inhalation of UO{sub 2} and U{sub 3}O{sub 8} were calculated based on original and revised HRTM. The results show that the revised HRTM increases lung retention and uptakes to alimentary tract which cause the more faecal excretion. The results in this study confirm the effect of the changes of respiratory tract model on the uranium bioassay data although the more study is needed to apply to practical fields.

  2. Applications of HPLC/MS in the analysis of traditional Chinese medicines

    Science.gov (United States)

    Li, Miao; Hou, Xiao-Fang; Zhang, Jie; Wang, Si-Cen; Fu, Qiang; He, Lang-Chong

    2012-01-01

    In China, traditional Chinese medicines (TCMs) have been used in clinical applications for thousands of years. The successful hyphenation of high-Performance liquid chromatography (HPLC) and mass spectrometry (MS) has been applied widely in TCMs and biological samples analysis. Undoubtedly, HPLC/MS technique has facilitated the understanding of the treatment mechanism of TCMs. We reviewed more than 350 published papers within the last 5 years on HPLC/MS in the analysis of TCMs. The present review focused on the applications of HPLC/MS in the component analysis, metabolites analysis, and pharmacokinetics of TCMs etc. 50% of the literature is related to the component analysis of TCMs, which show that this field is the most populär type of research. In the metabolites analysis, HPLC coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry has been demonstrated to be the powerful tool for the characterization of structural features and fragmentation behavior patterns. This paper presented a brief overview of the applications of HPLC/MS in the analysis of TCMs. HPLC/MS in the fingerprint analysis is reviewed elsewhere. PMID:29403684

  3. Evaluating the efficacy of biological and conventional insecticides with the new 'MCD bottle' bioassay.

    Science.gov (United States)

    Sternberg, Eleanore D; Waite, Jessica L; Thomas, Matthew B

    2014-12-16

    Control of mosquitoes requires the ability to evaluate new insecticides and to monitor resistance to existing insecticides. Monitoring tools should be flexible and low cost so that they can be deployed in remote, resource poor areas. Ideally, a bioassay should be able to simulate transient contact between mosquitoes and insecticides, and it should allow for excito-repellency and avoidance behaviour in mosquitoes. Presented here is a new bioassay, which has been designed to meet these criteria. This bioassay was developed as part of the Mosquito Contamination Device (MCD) project and, therefore, is referred to as the MCD bottle bioassay. Presented here are two experiments that serve as a proof-of-concept for the MCD bottle bioassay. The experiments used four insecticide products, ranging from fast-acting, permethrin-treated, long-lasting insecticide nets (LLINs) that are already widely used for malaria vector control, to the slower acting entomopathogenic fungus, Beauveria bassiana, that is currently being evaluated as a prospective biological insecticide. The first experiment used the MCD bottle to test the effect of four different insecticides on Anopheles stephensi with a range of exposure times (1 minute, 3 minutes, 1 hour). The second experiment is a direct comparison of the MCD bottle and World Health Organization (WHO) cone bioassay that tests a subset of the insecticides (a piece of LLIN and a piece of netting coated with B. bassiana spores) and a further reduced exposure time (5 seconds) against both An. stephensi and Anopheles gambiae. Immediate knockdown and mortality after 24 hours were assessed using logistic regression and daily survival was assessed using Cox proportional hazards models. Across both experiments, fungus performed much more consistently than the chemical insecticides but measuring the effect of fungus required monitoring of mosquito mortality over several days to a week. Qualitatively, the MCD bottle and WHO cone performed comparably

  4. Single-core magnetic markers in rotating magnetic field based homogeneous bioassays and the law of mass action

    Energy Technology Data Exchange (ETDEWEB)

    Dieckhoff, Jan, E-mail: j.dieckhoff@tu-bs.de [Institut fuer Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig (Germany); Schrittwieser, Stefan; Schotter, Joerg [Molecular Diagnostics, AIT Austrian Institute of Technology, Vienna (Austria); Remmer, Hilke; Schilling, Meinhard; Ludwig, Frank [Institut fuer Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig (Germany)

    2015-04-15

    In this work, we report on the effect of the magnetic nanoparticle (MNP) concentration on the quantitative detection of proteins in solution with a rotating magnetic field (RMF) based homogeneous bioassay. Here, the phase lag between 30 nm iron oxide single-core particles and the RMF is analyzed with a fluxgate-based measurement system. As a test analyte anti-human IgG is applied which binds to the protein G functionalized MNP shell and causes a change of the phase lag. The measured phase lag changes for a fixed MNP and a varying analyte concentration are modeled with logistic functions. A change of the MNP concentration results in a nonlinear shift of the logistic function with the analyte concentration. This effect results from the law of mass action. Furthermore, the bioassay results are used to determine the association constant of the binding reaction. - Highlights: • A rotating magnetic field based homogeneous bioassay concept was presented. • Here, single-core iron oxide nanoparticles are applied as markers. • The impact of the particle concentration on the bioassay results is investigated. • The relation between particle concentration and bioassay sensitivity is nonlinear. • This finding can be reasonably explained by the law of mass action.

  5. Vergelijking van HPLC-methoden voor de bepaling van pentachloorfenol in houtmonsters

    NARCIS (Netherlands)

    Goewie; C.E.; Berkhoff; C.J.

    1986-01-01

    Een vergelijkend onderzoek is verricht naar de bruikbaarheid van verschillende detectiemethoden in combinatie met HPLC voor de analyse van pentachloorfenol in hout. In het onderzoek wordt RP-HPLC met UK en amperometrische detectie beschreven, evenals NP-HPLC met elektroneninvangdetectie. In

  6. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    Science.gov (United States)

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  7. Functional diagnostics for thyrotropin hormone receptor autoantibodies: bioassays prevail over binding assays.

    Science.gov (United States)

    Lytton, Simon David; Schluter, Anke; Banga, Paul J

    2018-06-01

    Autoantibodies to the thyrotropin hormone receptor (TSH-R) are directly responsible for the hyperthyroidism in Graves' disease and mediate orbital manifestations in Graves' orbitopathy (otherwise known as thyroid eye disease). These autoantibodies are heterogeneous in their function and collectively referred to as TRAbs. Measurement of TRAbs is clinically important for diagnosis of a variety of conditions and different commercial assays with high sensitivity and specificity are available for diagnostic purposes. This review provides overwhelming evidence that the TRAbs detected in binding assays by mainly the automated electrochemical luminescence immunoassays (ECLIA) do not distinguish TRAbs that stimulate the TSH-R (called TSIs or TSAbs) and TRAbs that just inhibit the binding of TSH without stimulating the TSH-R (called TBAbs). However, TSAbs and TBAbs have divergent pathogenic roles, and depending which fraction predominates cause different clinical symptoms and engender different therapeutic regimen. Therefore, diagnostic distinction of TSAbs and TBAbs is of paramount clinical importance. To date, only bioassays such as the Mc4 TSH-R bioassay (Thyretain TM , Quidel) and the Bridge assay (Immulite 2000, Siemens) can measure TSAbs, with only the former being able to distinguish between TSAbs and TBAbs. On this note, it is strongly recommended to only use the term TSI or TSAb when reporting the results of bioassays, whereas the results of automated TRAb binding assays should be reported as TRAbs (of undetermined functional significance). This review aims to present a technical and analytical account of leading commercial diagnostic methods of anti-TSH-R antibodies, a metaanalysis of their clinical performance and a perspective for the use of cell based TSH-R bioassays in the clinical diagnostics of Graves' disease.

  8. Seasonally and regionally determined indication potential of bioassays in contaminated river sediments.

    Science.gov (United States)

    Hilscherová, Klára; Dusek, Ladislav; Sídlová, Tereza; Jálová, Veronika; Cupr, Pavel; Giesy, John P; Nehyba, Slavomír; Jarkovský, Jirí; Klánová, Jana; Holoubek, Ivan

    2010-03-01

    River sediments are a dynamic system, especially in areas where floods occur frequently. In the present study, an integrative approach is used to investigate the seasonal and spatial dynamics of contamination of sediments from a regularly flooded industrial area in the Czech Republic, which presents a suitable model ecosystem for pollutant distribution research at a regional level. Surface sediments were sampled repeatedly to represent two different hydrological situations: spring (after the peak of high flow) and autumn (after longer period of low flow). Samples were characterized for abiotic parameters and concentrations of priority organic pollutants. Toxicity was assessed by Microtox test; genotoxicity by SOS-chromotest and green fluorescent protein (GFP)-yeast test; and the presence of compounds with specific mode of action by in vitro bioassays for dioxin-like activity, anti-/androgenicity, and anti-/estrogenicity. Distribution of organic contaminants varied among regions and seasonally. Although the results of Microtox and genotoxicity tests were relatively inconclusive, all other specific bioassays led to statistically significant regional and seasonal differences in profiles and allowed clear separation of upstream and downstream regions. The outcomes of these bioassays indicated an association with concentrations of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) as master variables. There were significant interrelations among dioxin-like activity, antiandrogenicity and content of organic carbon, clay, and concentration of PAHs and PCBs, which documents the significance of abiotic factors in accumulation of pollutants. The study demonstrates the strength of the specific bioassays in indicating the changes in contamination and emphasizes the crucial role of a well-designed sampling plan, in which both spatial and temporal dynamics should be taken into account, for the correct interpretations of information in risk assessments.

  9. On-line radioactivity detector for HPLC

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1986-01-01

    Over the last ten years the technique of high performance liquid chromotography (HPLC) has become extensively employed for the separation and quantitation of various biological, organic, and inorganic substances. The use of HPLC for the separation of various metabolic compounds has become routine. The major problem of analyzing the metabolism process is that the quantitation is accomplished by the use of radioactive substrates. Until recently the only method to quantitate these radioactive compounds eluting from the HPLC was by collecting fractions at preset times, removing aliquots and quantitating in a liquid scintillation counter. Once the radioactivity present in each fraction was determined, the results were plotted on a graph and the area of each of the radioactive peaks was determined. This entire process required from 3-20 hours. The introduction of the flow through radioactivity detector enable the investigator to directly quantitate the radioactive peaks as they elute from the HPLC in real time and at about one-tenth the original cost of the previous methods. The detection limits of this technique are dependent on the residence time of the sample in the flow cell and the type of flow cell used for the analysis. Using a 2.5 ml liquid flow cell, (mixing with liquid scintillation solution), base line resolution can be obtained for peaks 1.5 minutes apart, and a sensitivity of 70 dpm for tritium and 30 dpm for carbon-14 can be achieved

  10. Comparison of liquid chromatographic and bioassay procedures for determining depletion of intramuscularly injected tylosin.

    Science.gov (United States)

    Moats, W A; Harris, E W; Steele, N C

    1985-01-01

    Crossbred pigs weighing 80-110 kg were injected intramuscularly in the ham with 8.8 mg/kg tylosin. Animals were slaughtered in groups of 3 at intervals of 4 h, and 1, 2, 4, and 8 days after injection, and samples of blood, injected muscle, uninjected muscle, liver, and kidney were analyzed by liquid chromatography (LC) and by bioassay using Sarcina lutea as the test organism. The LC method was far more sensitive with a detection limit of less than 0.1 ppm, while the detection limit by bioassay was about 0.5 ppm in tissue. Results by bioassay and LC sometimes differed considerably for tissue samples. Residues in all tissues were below the tolerance limit of 0.2 ppm at 24 h, except in the injected muscle in one animal. Residues were not detected in any tissue of any animal at 48 h after treatment.

  11. Fluorescent bioassays for toxic metals in milk and yoghurt

    Science.gov (United States)

    2012-01-01

    Background From a human health viewpoint, contaminated milk and its products could be a source of long-term exposure to toxic metals. Simple, inexpensive, and on-site assays would enable constant monitoring of their contents. Bioassays that can measure toxic metals in milk or yoghurt might reduce the risk. For this purpose, the green fluorescent protein (GFP)-tagged trans factors, ArsR-GFP and CadC-GFP, together with their cis elements were used to develop such bioassays. Results ArsR-GFP or CadC-GFP, which binds either toxic metal or DNA fragment including cis element, was directly mixed with cow’s milk or yoghurt within a neutral pH range. The fluorescence of GFP, which is reflected by the association/dissociation ratio between cis element and trans factor, significantly changed with increasing externally added As (III) or Cd (II) whereas smaller responses to externally added Pb (II) and Zn (II) were found. Preparation and dilution of whey fraction at low pH were essential to intrinsic zinc quantification using CadC-GFP. Using the extraction procedure and bioassay, intrinsic Zn (II) concentrations ranging from 1.4 to 4.8 mg/l for milk brands and from 1.2 to 2.9 mg/kg for yoghurt brands were determined, which correlated to those determined using inductively coupled plasma atomic emission spectroscopy. Conclusions GFP-tagged bacterial trans factors and cis elements can work in the neutralized whole composition and diluted whey fraction of milk and yoghurt. The feature of regulatory elements is advantageous for establishment of simple and rapid assays of toxic metals in dairy products. PMID:23098077

  12. Fluorescent bioassays for toxic metals in milk and yoghurt

    Directory of Open Access Journals (Sweden)

    Siddiki Mohammad Shohel

    2012-10-01

    Full Text Available Abstract Background From a human health viewpoint, contaminated milk and its products could be a source of long-term exposure to toxic metals. Simple, inexpensive, and on-site assays would enable constant monitoring of their contents. Bioassays that can measure toxic metals in milk or yoghurt might reduce the risk. For this purpose, the green fluorescent protein (GFP-tagged trans factors, ArsR-GFP and CadC-GFP, together with their cis elements were used to develop such bioassays. Results ArsR-GFP or CadC-GFP, which binds either toxic metal or DNA fragment including cis element, was directly mixed with cow’s milk or yoghurt within a neutral pH range. The fluorescence of GFP, which is reflected by the association/dissociation ratio between cis element and trans factor, significantly changed with increasing externally added As (III or Cd (II whereas smaller responses to externally added Pb (II and Zn (II were found. Preparation and dilution of whey fraction at low pH were essential to intrinsic zinc quantification using CadC-GFP. Using the extraction procedure and bioassay, intrinsic Zn (II concentrations ranging from 1.4 to 4.8 mg/l for milk brands and from 1.2 to 2.9 mg/kg for yoghurt brands were determined, which correlated to those determined using inductively coupled plasma atomic emission spectroscopy. Conclusions GFP-tagged bacterial trans factors and cis elements can work in the neutralized whole composition and diluted whey fraction of milk and yoghurt. The feature of regulatory elements is advantageous for establishment of simple and rapid assays of toxic metals in dairy products.

  13. Efficient algal bioassay based on short-term photosynthetic response

    International Nuclear Information System (INIS)

    Giddings, J.M.; Stewart, A.J.; O'Neill, R.V.; Gardner, R.H.

    1983-01-01

    A procedure is described for measuring the effects of toxicants on algal photosynthesis (carbon-14 bicarbonate (H 14 CO 3 )uptake) in 4-h experiments. The results for individual aromatic compounds and the water-soluble fraction (WSF) of a synthetic oil are presented as examples of applications of the bioassay. The toxicity of the WSF varied among the seven algal species tested, and the responses of some species were pH-dependent. With Selenastrum capricornutum as the test organism, the bioassay results were unaffected by variations in pH from 7.0 to 9.0, light intensity from 40 to 200 μeinsteins m -2 s -1 , culture density up to 0.5 mg chlorophyll a per litre, and agitation up to 100 rpm. The photosynthesis bioassay is simpler and faster (4 h versus 4 to 14 days), uses smaller culture volumes, and requires less space than static culture-growth tests. One person can conveniently test four materials per day, and the entire procedure, including preparation, exposure, and analysis, takes less than two days. The short incubation time reduces bottle effects such as pH changes, accumulation of metabolic products, nutrient depletion, and bacterial growth. Processes that remove or alter the test materials are also minimized. The data presented here indicate that algal photosynthesis is inhibited at toxicant concentrations similar to those that cause acute effects in aquatic animals. A model of a pelagic ecosystem is used to demonstrate that even temporary (seven-day) inhibition of algal photosynthesis can have a measurable impact on other trophic levels, particularly if the other trophic levels are also experiencing toxic effects. 25 references, 6 figures, 1 table

  14. High-throughput mosquito and fly bioassay system for natural and artificial substrates treated with residual insecticides.

    Science.gov (United States)

    Aldridge, Robert L; Wynn, W Wayne; Britch, Seth C; Allan, Sandra A; Walker, Todd W; Geden, Christopher J; Hogsette, Jerome A; Linthicum, Kenneth J

    2013-03-01

    A high-throughput bioassay system to evaluate the efficacy of residual pesticides against mosquitoes and muscid flies with minimal insect handling was developed. The system consisted of 4 components made of readily available materials: 1) a CO2 anaesthetizing chamber, 2) a specialized aspirator, 3) a cylindrical flat-bottomed glass bioassay chamber assembly, and 4) a customized rack.

  15. Assessment of N and P in organic fertilizer using the missing element technique and a microbial bioassay

    International Nuclear Information System (INIS)

    Salas, E.; Ramirez, C.

    2002-01-01

    Assessment of N and P in organic fertilizers using the missing element technique and a microbial bioassay.Through a greenhouse bioassay, using sorghum (Sorghum vulgare) as a test plant, and a microbial assay the availability of N and P in 6 substrates was determined, namely: soil alone and in combination with several organic amendments 10% W/W of chicken manure (CM), compost (C), bocashi (B), vermicompost (V) and coffe hulls (Br). In the microbial assay a complete randomized design with 6 replicates was used; the microbial biomass (BM) was determined 2 days after the glucose amendment of each treatment. In both bioassays a 2 X 2 factorial (N and P fertilization) was establish and the following combinations resulted: +N, +P, +P+N and -P-N (control). For the greenhouse experiment, a complete randomized design with 4 replicates was used. Above-ground plant material of sorghum was harvested 34 days after showing to determine plant dry weight (PS) and content of N and P. Both assays showed a response to the soil amendment with N and P. Soil treatments with CM, C and B showed the highest values of PS and BM. Soil treatment with CM amended with N, P or both did not showed a response in PS or BM, in C and B there was a response to N addition but not to P. In treatments with V and Br, the lowest values for PS and BM were obtained, and there was a growth response to N and P. Both bioassays were able to pinpoint N and P defficiencies in the soil as well in some of the mixtures of soil with organic amendments. A high correlation was encountered between the greenhouse assay and the microbial bioassay (r= 0.86, P=0.0001). Therefore, the microbial bioassay can be a cheaper alternative to the plant bioassay not only to evaluate the nutritional quality of compost but also to identify nutrient deficiencies in soils as well as in substrates amended with organic fertilizers. (Author) [es

  16. Phototoxicity activity of Psoralea drupacea L. using Atremia salina bioassay system

    Directory of Open Access Journals (Sweden)

    Mohammad Ramezani

    2011-07-01

    Conclusion: The result showed that P. drupacea methanolic extract and chloroform fraction have phototoxicity in A. salina bioassay system and their toxic effect is related to phototoxic constituents such as psoralen.

  17. UTILITY OF A FULL LIFE-CYCLE COPEPOD BIOASSAY APPROACH FOR ASSESSMENT OF SEDIMENT-ASSOCIATED CONTAMINANT MIXTURES. (R825279)

    Science.gov (United States)

    AbstractWe compared a 21 day full life-cycle bioassay with an existing 14 day partial life-cycle bioassay for two species of meiobenthic copepods, Microarthridion littorale and Amphiascus tenuiremis. We hypothesized that full life-cycle tests would bette...

  18. Bioassay-Guided Isolation of Neuroprotective Compounds from Uncaria rhynchophylla against Beta-Amyloid-Induced Neurotoxicity

    Directory of Open Access Journals (Sweden)

    Yan-Fang Xian

    2012-01-01

    Full Text Available Uncaria rhynchophylla is a component herb of many Chinese herbal formulae for the treatment of neurodegenerative diseases. Previous study in our laboratory has demonstrated that an ethanol extract of Uncaria rhynchophylla ameliorated cognitive deficits in a mouse model of Alzheimer’s disease induced by D-galactose. However, the active ingredients of Uncaria rhynchophylla responsible for the anti-Alzheimer’s disease activity have not been identified. This study aims to identify the active ingredients of Uncaria rhynchophylla by a bioassay-guided fractionation approach and explore the acting mechanism of these active ingredients by using a well-established cellular model of Alzheimer’s disease, beta-amyloid- (Aβ- induced neurotoxicity in PC12 cells. The results showed that six alkaloids, namely, corynoxine, corynoxine B, corynoxeine, isorhynchophylline, isocorynoxeine, and rhynchophylline were isolated from the extract of Uncaria rhynchophylla. Among them, rhynchophylline and isorhynchophylline significantly decreased Aβ-induced cell death, intracellular calcium overloading, and tau protein hyperphosphorylation in PC12 cells. These results suggest that rhynchophylline and isorhynchophylline are the major active ingredients responsible for the protective action of Uncaria rhynchophylla against Aβ-induced neuronal toxicity, and their neuroprotective effect may be mediated, at least in part, by inhibiting intracellular calcium overloading and tau protein hyperphosphorylation.

  19. Building bio-assays with magnetic particles on a digital microfluidic platform.

    Science.gov (United States)

    Kokalj, Tadej; Pérez-Ruiz, Elena; Lammertyn, Jeroen

    2015-09-25

    Digital microfluidics (DMF) has emerged as a promising liquid handling technology for a variety of applications, demonstrating great potential both in terms of miniaturization and automation. DMF is based on the manipulation of discrete, independently controllable liquid droplets, which makes it highly reconfigurable and reprogrammable. One of its most exclusive advantages, compared to microchannel-based microfluidics, is its ability to precisely handle solid nano- and microsized objects, such as magnetic particles. Magnetic particles have become very popular in the last decade, since their high surface-to-volume ratio and the possibility to magnetically separate them from the matrix make them perfect suitable as a solid support for bio-assay development. The potential of magnetic particles in DMF-based bio-assays has been demonstrated for various applications. In this review we discuss the latest developments of magnetic particle-based DMF bio-assays with the aim to present, identify and analyze the trends in the field. We also discuss the state-of-the art of device integration, current status of commercialization and issues that still need to be addressed. With this paper we intend to stimulate researchers to exploit and unveil the potential of these exciting tools, which will shape the future of modern biochemistry, microbiology and biomedical diagnostics. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Investigation of animal and algal bioassays for reliable saxitoxin ecotoxicity and cytotoxicity risk evaluation.

    Science.gov (United States)

    Perreault, François; Matias, Marcelo Seleme; Melegari, Silvia Pedroso; Pinto, Catia Regina Silva de Carvalho; Creppy, Edmond Ekué; Popovic, Radovan; Matias, William Gerson

    2011-05-01

    Contamination of water bodies by saxitoxin can result in various toxic effects in aquatic organisms. Saxitoxin contamination has also been shown to be a threat to human health in several reported cases, even resulting in death. In this study, we evaluated the sensitivity of animal (Neuro-2A) and algal (Chlamydomonas reinhardtii) bioassays to saxitoxin effect. Neuro-2A cells were found to be sensitive to saxitoxin, as shown by a 24 h EC50 value of 1.5 nM, which was obtained using a cell viability assay. Conversely, no saxitoxin effect was found in any of the algal biomarkers evaluated, for the concentration range tested (2-128 nM). These results indicate that saxitoxin may induce toxic effects in animal and human populations at concentrations where phytoplankton communities are not affected. Therefore, when evaluating STX risk of toxicity, algal bioassays do not appear to be reliable indicators and should always be conducted in combination with animal bioassays. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Experimental and Computational Characterization of Biological Liquid Crystals: A Review of Single-Molecule Bioassays

    Directory of Open Access Journals (Sweden)

    Sungsoo Na

    2009-09-01

    Full Text Available Quantitative understanding of the mechanical behavior of biological liquid crystals such as proteins is essential for gaining insight into their biological functions, since some proteins perform notable mechanical functions. Recently, single-molecule experiments have allowed not only the quantitative characterization of the mechanical behavior of proteins such as protein unfolding mechanics, but also the exploration of the free energy landscape for protein folding. In this work, we have reviewed the current state-of-art in single-molecule bioassays that enable quantitative studies on protein unfolding mechanics and/or various molecular interactions. Specifically, single-molecule pulling experiments based on atomic force microscopy (AFM have been overviewed. In addition, the computational simulations on single-molecule pulling experiments have been reviewed. We have also reviewed the AFM cantilever-based bioassay that provides insight into various molecular interactions. Our review highlights the AFM-based single-molecule bioassay for quantitative characterization of biological liquid crystals such as proteins.

  2. Evaluation of soil bioassays for use at Washington state hazardous waste sites: A pilot study

    International Nuclear Information System (INIS)

    Blakley, N.; Norton, D.; Stinson, M.; Boyer, R.

    1994-01-01

    The Washington State Department of Ecology (Ecology) is developing guidelines to assess soil toxicity at hazardous waste sites being investigated under the Washington Model Toxics Control Act Cleanup Regulation. To evaluate soil toxicity, Ecology selected five bioassay protocols -- Daphnia, Earthworm, Seedling, Fathead Minnow, and Frog Embryo Teratogenesis Assay Xenopus (FETAX) -- for use as screening level assessment tools at six State hazardous waste sites. Sites contained a variety of contaminants including metals, creosote, pesticides, and petroleum products (leaking underground storage tanks). Three locations, representing high, medium, and low levels of contamination, were samples at each site. In general, the high contaminant samples resulted in the highest toxic response in all bioassays. The order of site toxicity, as assessed by overall toxic response, is creosote, petroleum products, metals, and pesticides. Results indicate that human health standards, especially for metals, may not adequately protect some of the species tested. The FETAX bioassay had the greatest overall number of toxic responses and lowest variance. The seedling and Daphnia bioassays had lower and similar overall toxic response results, followed by the earthworm and fathead minnow. Variability was markedly highest for the seedling. The Daphnia and fathead minnow variability were similar to the FETAX level, while the earthworm variability was slightly higher

  3. Bioassay-guided studies on the cytotoxic and in vitro trypanocidal ...

    African Journals Online (AJOL)

    This paper reports a bioassay-guided study to search for possible biological activity (cytotoxic and trypanocidal) in two Ugandan medicinal plants. The methodology adopted was the so-called ping-pong approach, involving phytochemical purification (column chromatography and preparative thin layer chromatography), ...

  4. Intemational collaborative study on the preparation of 1st international standard for rhTSH for bioassay

    International Nuclear Information System (INIS)

    Huang Ying; Shen Hongzheng; Yu Ting; Xu Ligen

    2007-01-01

    The history of the international collaborative studies on the preparation of standards of TSH for bioassay and immunoassay was reviewed. The result of collaborative study on the 1st international standard for thyroid-stimulating hormone, recombinant, human, for bioassay was reported in detail in this article. Based on the results of this collaborative study, it is proposed that the candidate standard be established as the international standard for rhTSH for bioassay, and be assigned an activity of 9.5 IU per ampoule. The national standard preparation of TSH for immunoassay was also reassayed, revealing the potency to be 0.557 mIU/ampoule, i.e. 92. 8% of the labelled value of 0.600mIU/ampoule, a reasonable consistency. (authors)

  5. Direct 13C NMR Detection in HPLC Hyphenation Mode

    DEFF Research Database (Denmark)

    Wubshet, Sileshi Gizachew; Johansen, Kenneth; Nyberg, Nils

    2012-01-01

    Solid phase extraction (SPE) was introduced as a crucial step in the HPLC-SPE-NMR technique to enable online analyte enrichment from which proton-detected NMR experiments on submicrogram amounts from complex mixtures were possible. However, the significance of direct-detected (13)C NMR experiments...... application of HPLC-SPE-NMR analysis using direct-detected (13)C NMR spectra. HPLC column loading, accumulative SPE trappings, and the effect of different elution solvents were evaluated and optimized. A column loading of approximately 600 mug of a prefractionated triterpenoid mixture, six trappings...

  6. HPLC-RID-DAD-MS analysis of 18F-Fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Macasek, F.; Buriova, E.; Bruder, P.

    2001-01-01

    Objective of new method of FDG analysis development is to replace existing tests by more complex assay. In this work, a liquid chromatography/refractive index detector/diode array detector/mass spectrometric detector combination (HPLC/RID/DAD/MSD) was used for development of a complex routine technique. Optimization of the HPLC/MS analysis was performed investigating MSD analytical signal as a function of various eluent composition. HPLC-RID-DAD-MSD analysis has potentiality of a complex quality control of radiopharmaceuticals, FDG in particular, providing information about: isotope composition; chemical composition; biochemical composition; radiation stability; pharmacodynamics. (author)

  7. Bioassays with terrestrial and aquatic species as monitoring tools of hydrocarbon degradation.

    Science.gov (United States)

    Bori, Jaume; Vallès, Bettina; Ortega, Lina; Riva, Maria Carme

    2016-09-01

    In this study chemical analyses and ecotoxicity tests were applied for the assessment of a heavily hydrocarbon-contaminated soil prior and after the application of a remediation procedure that consisted in the stimulation of soil autochthonous populations of hydrocarbon degraders in static-ventilated biopiles. Terrestrial bioassays were applied in mixtures of test soils and artificial control soil and studied the survival and reproduction of Eisenia fetida and the avoidance response of E. fetida and Folsomia candida. Effects on aquatic organisms were studied by means of acute tests with Vibrio fischeri, Raphidocelis subcapitata, and Daphnia magna performed on aqueous elutriates from test soils. The bioremediation procedure led to a significant reduction in the concentration of hydrocarbons (from 34264 to 3074 mg kg(-1), i.e., 91 % decrease) and toxicity although bioassays were not able to report a percentage decrease of toxicity as high as the percentage reduction. Sublethal tests proved the most sensitive terrestrial bioassays and avoidance tests with earthworms and springtails showed potential as monitoring tools of hydrocarbon remediation due to their high sensitivity and short duration. The concentrations of hydrocarbons in water extracts from test soils were 130 and 100 μg L(-1) before and after remediation, respectively. Similarly to terrestrial tests, most aquatic bioassays detected a significant reduction in toxicity, which was almost negligible at the end of the treatment. D. magna survival was the most affected by soil elutriates although toxicity to the crustacean was associated to the salinity of the samples rather than to the concentration of hydrocarbons. Ecotoxicity tests with aqueous soil elutriates proved less relevant in the assessment of hydrocarbon-contaminated soils due to the low hydrosolubility of hydrocarbons and the influence of the physicochemical parameters of the aquatic medium.

  8. Interpretation of bioassay data from nuclear fuel fabrication workers

    International Nuclear Information System (INIS)

    Melo, D.; Xavier, M.

    2005-01-01

    Full text: In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Although in this kind of facility the main route of intake is inhalation, ingestion may occur in some situations. The interpretation of the bioassay data is very complex, since it is necessary taking into account all the different parameters, which is a big challenge. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this paper, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. Results of monitoring of working environment may provide information that assists in interpretation on particle size, chemical form and solubility, time of intake. A group of seventeen workers from controlled area of the fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary and faecal excretion (collected over a period of 3 consecutive days), chest counting and personal air sampling. The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown to be the more appropriate methodology for assessing internal dose in this situation. (author)

  9. Analysis of brominated and phosphate-based flame retardants in polymer samples by HPLC-UV/MS and online-GPC-HPLC-UV

    Energy Technology Data Exchange (ETDEWEB)

    Schlummer, M.; Brandl, F. [Fraunhofer-Institut fuer Verfahrenstechnik und Verpackung (IVV), Freising (Germany); Maeurer, A.

    2004-09-15

    Here we present two analytical approaches for the identification and quantification of brominated and phosphate-based flame retardants. The first is an HPLC-UV/MS approach, which allows the separation and unequivocal identification and quantification of at least 15 different technical flame retardants. The second approach was set-up as a screening tool, consisting of a GPC separation coupled to an HPLC-UV device.

  10. Optimization and field use of a bioassay to monitor sea lice Lepeophtheirus salmonis sensitivity to emamectin benzoate.

    Science.gov (United States)

    Westcott, Jillian D; Stryhn, Henrik; Burka, John F; Hammell, K Larry

    2008-04-01

    A bioassay for sea lice Lepeophtheirus salmonis sensitivity towards emamectin benzoate (EMB) was validated for field use. A probit regression model with natural responsiveness was used for the number of affected (moribund or dead) sea lice in bioassays involving different concentrations of EMB. Bioassay optimization included an evaluation of the inter-rater reliability of sea lice responsiveness to EMB and an evaluation of gender-related differences in susceptibility. Adoption of a set of bioassay response criteria improved the concordance (evaluated using the concordance correlation coefficient) between raters' assessments and the model estimation of EC50 values (the 'effective concentration' leading to a response of 50% of the lice not prone to natural response). An evaluation of gender-related differences in EMB susceptibility indicated that preadult stage female sea lice exhibited a significantly larger sensitivity towards EMB in 12 of 19 bioassays compared to preadult males. In order to evaluate sea lice sensitivity to EMB in eastern Canada, the intensive salmon farming area in the Bay of Fundy in southwestern New Brunswick was divided into 4 distinct regions based on industry health management practices and hydrographics. A total of 38 bioassays were completed from 2002 to 2005 using populations of preadult stage sea lice collected from Atlantic salmon Salmo salar farms within the 4 described regions. There was no significant overall effect of region or year on EC50 values; however, analysis of variance indicated a significant effect of time of year on EC50 values in 2002 and a potential effect in 2004 to 2005. Although the range of EC50 values obtained in this 3 yr study did not appear sufficient to affect current clinical success in the control of sea lice, the results suggest a seasonal- or temperature-associated variation in sensitivity to EMB. This will need to be considered if changes in EMB efficacy occur in the future.

  11. 72 - 80_Aminu_HPLC1

    African Journals Online (AJOL)

    pc

    HPLC, Gymnema sylvestre, carbohydrate hydrolyzing enzymes, lipid a chronic .... Method. Test for Tannins and Flavonoids was by. Trease and Evans (2002). Soluble Starch ... Fenton reaction was quantified using 2- deoxyribose oxidative ...

  12. Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods

    Energy Technology Data Exchange (ETDEWEB)

    D' Assignies, Gaspard; Ruel, Martin; Khiat, Abdesslem; Lepanto, Luigi; Kauffmann, Claude; Tang, An [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement de Radiologie, Montreal, Quebec (Canada); Chagnon, Miguel [Universite de Montreal (UDEM), Departement de Mathematiques et de Statistique, Montreal, Quebec (Canada); Gaboury, Louis [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement d' Anatomo-Pathologie, Montreal, Quebec (Canada); Boulanger, Yvan [Centre Hospitalier de l' Universite de Montreal (CHUM), Departement de Radiologie, Montreal, Quebec (Canada); Hopital Saint-Luc du CHUM, Departement de Radiologie, Montreal, Quebec (Canada)

    2009-08-15

    The purpose was to evaluate the ability of three magnetic resonance (MR) techniques to detect liver steatosis and to determine which noninvasive technique (MR, bioassays) or combination of techniques is optimal for the quantification of hepatic fat using histopathology as a reference. Twenty patients with histopathologically proven steatosis and 24 control subjects underwent single-voxel proton MR spectroscopy (MRS; 3 voxels), dual-echo in phase/out of phase MR imaging (DEI) and diffusion-weighted MR imaging (DWI) examinations of the liver. Blood or urine bioassays were also performed for steatosis patients. Both MRS and DEI data allowed to detect steatosis with a high sensitivity (0.95 for MRS; 1 for DEI) and specificity (1 for MRS; 0.875 for DEI) but not DWI. Strong correlations were found between fat fraction (FF) measured by MRS, DEI and histopathology segmentation as well as with low density lipoprotein (LDL) and cholesterol concentrations. A Bland-Altman analysis showed a good agreement between the FF measured by MRS and DEI. Partial correlation analyses failed to improve the correlation with segmentation FF when MRS or DEI data were combined with bioassay results. Therefore, FF from MRS or DEI appear to be the best parameters to both detect steatosis and accurately quantify fat liver noninvasively. (orig.)

  13. Evaluation of the toxic effects of arsenite, chromate, cadmium, and copper using a battery of four bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kyung-Seok; Lee, Pyeong-Koo [Korea Institute of Geoscience and Mineral Resources (KIGAM), Daejeon (Korea, Republic of). Geologic Environment Div.; Kong, In Chul [Yeungnam Univ., Kyungbuk (Korea, Republic of). Dept. of Environmental Engineering

    2012-09-15

    The sensitivities of four different kinds of bioassays to the toxicities of arsenite, chromate, cadmium, and copper were compared. The different bioassays exhibited different sensitivities, i.e., they responded to different levels of toxicity of each of the different metals. However, with the exception of the {alpha}-glucosidase enzyme activity, arsenite was the most toxic compound towards all the tested organisms, exhibiting the highest toxic effect on the seeds of Lactuca, with an EC{sub 50} value of 0.63 mg/L. The sensitivities of Lactuca and Raphanus were greater than the sensitivities of two other kinds of seeds tested. Therefore, these were the seeds appropriate for use in a seed germination assay. A high revertant mutagenic ratio (5:1) of Salmonella typhimurium was observed with an arsenite concentration of 0.1 {mu}g/plate, indicative of a high possibility of mutagenicity. These different results suggested that a battery of bioassays, rather than one bioassay alone, is needed as a more accurate and better tool for the bioassessment of environmental pollutants. (orig.)

  14. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses.

    Science.gov (United States)

    De Lange, H J; Van Griethuysen, C; Koelmans, A A

    2008-01-01

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics.

  15. BIOASSAY STUDIES OF METAL(II) COMPLEXES OF 2,2'-(ETHANE ...

    African Journals Online (AJOL)

    Preferred Customer

    diyldiimino)diacetic acid (EDDA) were prepared and characterized. Coordination complexes of the EDDA ... corresponding amines with alkyl halide to bear diammines of the same class with different substituents. ... Bioassay studies of metal(II) complexes of 2,2'-(ethane-1,2-diyldiimino)diacetic acid. Bull. Chem. Soc. Ethiop.

  16. A Bayesian statistical analysis of mouse dermal tumor promotion assay data for evaluating cigarette smoke condensate.

    Science.gov (United States)

    Kathman, Steven J; Potts, Ryan J; Ayres, Paul H; Harp, Paul R; Wilson, Cody L; Garner, Charles D

    2010-10-01

    The mouse dermal assay has long been used to assess the dermal tumorigenicity of cigarette smoke condensate (CSC). This mouse skin model has been developed for use in carcinogenicity testing utilizing the SENCAR mouse as the standard strain. Though the model has limitations, it remains as the most relevant method available to study the dermal tumor promoting potential of mainstream cigarette smoke. In the typical SENCAR mouse CSC bioassay, CSC is applied for 29 weeks following the application of a tumor initiator such as 7,12-dimethylbenz[a]anthracene (DMBA). Several endpoints are considered for analysis including: the percentage of animals with at least one mass, latency, and number of masses per animal. In this paper, a relatively straightforward analytic model and procedure is presented for analyzing the time course of the incidence of masses. The procedure considered here takes advantage of Bayesian statistical techniques, which provide powerful methods for model fitting and simulation. Two datasets are analyzed to illustrate how the model fits the data, how well the model may perform in predicting data from such trials, and how the model may be used as a decision tool when comparing the dermal tumorigenicity of cigarette smoke condensate from multiple cigarette types. The analysis presented here was developed as a statistical decision tool for differentiating between two or more prototype products based on the dermal tumorigenicity. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Cryopreserved semen in ecotoxicological bioassays: sensitivity and reliability of cryopreserved Sparus aurata spermatozoa.

    Science.gov (United States)

    Fabbrocini, Adele; D'Adamo, Raffaele; Del Prete, Francesco; Langellotti, Antonio Luca; Rinna, Francesca; Silvestri, Fausto; Sorrenti, Gerarda; Vitiello, Valentina; Sansone, Giovanni

    2012-10-01

    The aim of this study was to evaluate the feasibility of using cryopreserved S. aurata semen in spermiotoxicity tests. Cryopreservation is a biotechnology that can provide viable gametes and embryos on demand, rather than only in the spawning season, thus overcoming a limitation that has hindered the use of some species in ecotoxicological bioassays. Firstly, the sperm motility pattern of cryopreserved semen was evaluated after thawing by means of both visual and computer-assisted analyses. Motility parameters in the cryopreserved semen did not change significantly in the first hour after thawing, meaning that they were maintained for long enough to enable their use in spermiotoxicity tests. In the second phase of the research, bioassays were performed, using cadmium as the reference toxicant, in order to evaluate the sensitivity of cryopreserved S. aurata semen to ecotoxicological contamination. The sensitivity of the sperm motility parameters used as endpoints (motility percentages and velocities) proved to be comparable to what has been recorded for the fresh semen of other aquatic species (LOECs from 0.02 to 0.03 mg L(-1)). The test showed good reliability and was found to be rapid and easy to perform, requiring only a small volume of the sample. Moreover, cryopreserved semen is easy to store and transfer and makes it possible to perform bioassays in different sites or at different times with the same batch of semen. The proposed bioassay is therefore a promising starting point for the development of toxicity tests that are increasingly tailored to the needs of ecotoxicology and environmental quality evaluation strategies. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Retinoid quantification by HPLC/MS(n)

    Science.gov (United States)

    McCaffery, Peter; Evans, James; Koul, Omanand; Volpert, Amy; Reid, Kevin; Ullman, M. David

    2002-01-01

    Retinoic acid (RA) mediates most of the biological effects of vitamin A that are essential for vertebrate survival. It acts through binding to receptors that belong to the nuclear receptor transcription factor superfamily (Mangelsdorf et al. 1994). It is also a highly potent vertebrate teratogen. To determine the function and effects of endogenous and exogenous RA, it is important to have a highly specific, sensitive, accurate, and precise analytical procedure. Current analyses of RA and other retinoids are labor intensive, of poor sensitivity, have limited specificity, or require compatibility with RA reporter cell lines (Chen et al. 1995. BIOCHEM: Pharmacol. 50: 1257-1264; Creech Kraft et al. 1994. BIOCHEM: J. 301: 111-119; Lanvers et al. 1996. J. Chromatogr. B Biomed. Appl. 685: 233-240; Maden et al. 1998. DEVELOPMENT: 125: 4133-4144; Wagner et al. 1992. DEVELOPMENT: 116: 55-66). This paper describes an HPLC/mass spectrometry/mass spectrometry product ion scan (HPLC/MS(n)) procedure for the analysis of retinoids that employs atmospheric pressure chemical ionization MS. The retinoids are separated by normal-phase column chromatography with a linear hexane-isopropanol-dioxane gradient. Each retinoid is detected by a unique series of MS(n) functions set at optimal collision-induced dissociation energy (30% to 32%) for all MS(n) steps. The scan events are divided into three segments, based on HPLC elution order, to maximize the mass spectrometer duty cycle. The all-trans, 9-cis, and 13-cis RA isomers are separated, if desired, by an isocratic hexane-dioxane-isopropanol mobile phase. This paper describes an HPLC/MS(n) procedure possessing high sensitivity and specificity for retinoids.

  19. A review of metal (Pb and Zn) sensitive and pH tolerant bioassay organisms for risk screening of metal-contaminated acidic soils

    International Nuclear Information System (INIS)

    Chapman, E.Emily V.; Dave, Göran; Murimboh, John D.

    2013-01-01

    To improve risk estimates at the screening stage of Ecological Risk Assessment (ERA), short duration bioassays tailored to undisturbed soil cores from the contaminated site could be useful. However, existing standardized bioassays use disturbed soil samples and often pH sensitive organisms. This is a problem as naturally acidic soils are widespread. Changing soil properties to suit the test organism may change metal bioavailability, leading to erroneous risk estimates. For bioassays in undisturbed soil cores to be effective, species able to withstand natural soil properties must be identified. This review presents a critical examination of bioassay species' tolerance of acidic soils and sensitivity to metal contaminants such as Pb and Zn. Promising organisms include; Dendrobaena octaedra, Folsomia candida, Caenorhabditis elegans, Oppia nitens, Brassica rapa, Trifolium pratense, Allium cepa, Quercus rubra and Acer rubrum. The MetSTICK test and the Bait lamina test were also identified as suitable microorganism tests. -- Highlights: •Risk screening of metal contaminated soils should consider metal bioavailability. •Metal bioavailability is dependent on soil properties such as pH. •Many standardized bioassay organisms are sensitive to acidic soils. •This review identifies acid tolerant and metal sensitive bioassays and species. •The identified tests can improve risk screening of acidic metal contaminated soil. -- This review identifies bioassay species able to withstand naturally acidic soils while being sensitive to metal contaminants

  20. HPLC/MS analysis of glucose and fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Bruder, P.; Macasek, F.; Patakyova, A.; Buriova, E.

    2001-01-01

    Objective of a new method of FDG analysis development is to replace existing tests by a more complex assay. In this work, a liquid chromatography/refractive index detector/ radiometric detector/mass spectrometric detector combination (HPLC/RID/RAD/MSD) was used for development of a complex routine technique. Optimization of HPLC/MS analysis was performed investigating the MSD analytical signal as a function of various eluent composition. Solutions of glucose in methanol/water and acetonitrile/water solutions of various semi-volatile electrolytes (ammonium chloride, formic acid, ammonium formate) were analyzed on the Agilent 1100 HPLC/RID/DAD/MSD system either in the flow injection (FIA) mode of analysis, and after passing the samples through Zorbax C-18 column. The most intensive signals of the ions were obtained in the acetonitrile : 0.25% ammonium formate = 80:20 solutions. This eluent would be also used for the radioactive FDG analysis on the Asahipak NH2P columns. (authors)

  1. HPLC/MS analysis of glucose and fluorodeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Bruder, P; Macasek, F; Patakyova, A; Buriova, E [Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, 84215 Bratislava (Slovakia)

    2001-05-31

    Objective of a new method of FDG analysis development is to replace existing tests by a more complex assay. In this work, a liquid chromatography/refractive index detector/ radiometric detector/mass spectrometric detector combination (HPLC/RID/RAD/MSD) was used for development of a complex routine technique. Optimization of HPLC/MS analysis was performed investigating the MSD analytical signal as a function of various eluent composition. Solutions of glucose in methanol/water and acetonitrile/water solutions of various semi-volatile electrolytes (ammonium chloride, formic acid, ammonium formate) were analyzed on the Agilent 1100 HPLC/RID/DAD/MSD system either in the flow injection (FIA) mode of analysis, and after passing the samples through Zorbax C-18 column. The most intensive signals of the ions were obtained in the acetonitrile : 0.25% ammonium formate = 80:20 solutions. This eluent would be also used for the radioactive FDG analysis on the Asahipak NH2P columns. (authors)

  2. Reverse-phase HPLC analysis of human alpha crystallin.

    Science.gov (United States)

    Swamy, M S; Abraham, E C

    1991-03-01

    A rapid and highly sensitive reverse-phase HPLC (RP-HPLC) method was used to separate crystallin subunits from human alpha crystallin. Three distinct peaks were separated; by electrophoretic and immunological analyses the first and second peaks were identified as alpha B and alpha A respectively. On the other hand, peak 3 appeared to be a modified form of alpha crystallin. The ratio of alpha A and alpha B proteins was 3:1 in 1 day old lenses which gradually changed to 2:1 in 17 year old lenses and to 1:1 in the 50 and 82 year old whole lenses and 82 year old lens cortex, with a concomitant increase in the modified alpha, suggesting that alpha A subunits are relatively more involved in aggregation. Analysis of the 82 year old lens nucleus also supported this conclusion. The RP-HPLC analysis of the HMW aggregate fraction showed substantial enrichment of the modified alpha. The alpha A and alpha B subunits independently reassociated to form polymeric alpha crystallin whereas the modified alpha reassociated to form HMW aggregates as shown by molecular sieve HPLC. Hence it appears that the HMW aggregate peak was constituted by modified alpha crystallin. Only in the peak 3 material the 280 nm absorbance was about 2-fold higher than what was expected from the actual protein content. The data suggest that the changes induced by post-translational modifications may have some role in the formation of modified alpha. The present RP-HPLC method is useful in separating these modified alpha from the unmodified alpha A and alpha B subunits.

  3. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    Science.gov (United States)

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  4. Biomagnification of bioassay derived 2,3,7,8-tetrachlorodibenzo-p-dioxin equivalents

    Science.gov (United States)

    Jones, P.D.; Ankley, G.T.; Best, D. A.; Crawford, R.; DeGalan, N.; Giesy, J.P.; Kubiak, T.J.; Ludwig, J. P.; Newsted, J.L.; Tillitt, D. E.; Verbrugge, D.A.

    1993-01-01

    In recent years contamination of the Great Lakes ecosystem with planar chlorinated hydrocarbons (PCHs) has attracted considerable concern due to their known reproductive and teratogenic effects. The H4IIE bioassay has been standardized as a means of measuring the biological potency of a PCH mixture as 2,3,7,8-tetrachloro-p-dibenzodioxin equivalents (TCDD-EQ). Using this bioassay we have investigated the biomagnification of TCDD-EQ in a semi-closed ecosystem. The biomagnification of TCDD-EQ is demonstrated and results indicate that the food chain is the major pathway for TCDD-EQ through this ecosystem. The H4IIE assay system is demonstrated to be a viable integrative measure of the total concentration of TCDD-EQ in different trophic levels.

  5. Intercomparison programs - a tool for the implementation of a quality assurance program in bioassay

    International Nuclear Information System (INIS)

    Mesquita, Sueli A. de; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Santos, Maristela S.; Fernandes, Paulo C.P.

    2009-01-01

    In vitro bioassay laboratories need to have means to demonstrate that they are technically competent, operate an effective quality system, and are able to generate technically valid calibration and test results. The reliability of the results of measurements has a high influence on the reliability of the dose assessment. Inter-laboratory tests are one of the tools for assessing the analytical consistency of in vitro bioassay laboratories. The intercomparison exercises provide an opportunity to compare radiochemistry techniques for in vitro analysis of biological samples. The in vitro Laboratory of the Instituto de Radioprotecao e Dosimetria has therefore participated in the intercomparison exercises sponsored by PROCORAD, ARCAL and IAEA since 1998. The intercomparison exercises comprise measurements of gamma and beta emitters in urine samples and alpha emitters in urine and faecal samples. This paper presents the performance of the IRD in vitro bioassay laboratory in the past intercomparisons. The results demonstrate that in vitro laboratory is able to generate technically valid results, which also guarantee the support for a quality assurance program and accreditation by competent organism in Brazil. (author)

  6. Qualitative and Quantitative Analysis of Lignan Constituents in Caulis Trachelospermi by HPLC-QTOF-MS and HPLC-UV

    Directory of Open Access Journals (Sweden)

    Xiao-Ting Liu

    2015-05-01

    Full Text Available A high-performance liquid chromatography coupled with quadrupole tandem time-of-flight mass (HPLC-QTOF-MS and ultraviolet spectrometry (HPLC-UV was established for simultaneous qualitative and quantitative analysis of the major chemical constituents in Caulis Trachelospermi, respectively. The analysis was performed on an Agilent Zorbax Eclipse Plus C18 column (4.6 mm × 150 mm, 5 μm using a binary gradient system of water and methanol, with ultraviolet absorption at 230 nm. Based on high-resolution ESI-MS/MS fragmentation behaviors of the reference standards, the characteristic cleavage patterns of lignano-9, 9'-lactones and lignano-8'-hydroxy-9, 9'-lactones were obtained. The results demonstrated that the characteristic fragmentation patterns are valuable for identifying and differentiating lignano-9,9'-lactones and lignano-8'-hydroxy-9,9'-lactones. As such, a total of 25 compounds in Caulis Trachelospermi were unambiguously or tentatively identified via comparisons with reference standards or literature. In addition, 14 dibenzylbutyrolatone lignans were simultaneously quantified in Caulis Trachelospermi by HPLC-UV method. The method is suitable for the qualitative and quantitative analyses of dibenzylbutyrolatone lignans in Caulis Trachelospermi.

  7. Development of a new rapid HPLC method for the fractionation of histones

    International Nuclear Information System (INIS)

    Gurley, L.R.; Valdez, J.G.; Prentice, D.A.; Spall, W.D.

    1983-01-01

    To study histone functions, it is necessary to fractionate the histones into their five classes (H1, H2A, H2B, H3 and H4) and then to subfractionate these classes into variants having slightly different primary structures and into different phosphorylated and acetylated forms. With the advent of high-performance liquid chromatography (HPLC), it was hoped that laborious and time-consuming conventional methods could be replaced by a simple, rapid, high-resolving HPLC method for fractionating histones. However, problems of irreversible adsorption of the histones to HPLC column packings discouraged this development. Our laboratory has now determined that the strong adsorption of histones to HPLC columns results from two different forces: (1) polar interactions between the histones and the silanol groups of silica-based HPLC column packing, and (2) hydrophobic interactions between the histones and the bound organic phase of the column packings. By minimizing these forces, we have succeeded in developing an HPLC method suitable for histone studies

  8. Use of 236Pu and 242Pu as a radiochemical tracer for estimation of Pu in bioassay samples by fission track analysis

    International Nuclear Information System (INIS)

    Sawant, Pramilla D.; Prabhu, Supreetha P.; Kalsi, P.C.

    2008-01-01

    236 Pu and 242 Pu are routinely used as radiochemical yield monitors in India for bioassay monitoring of occupational workers by alpha spectrometry. Fission Track Analysis (FTA) is also being standardized for trace level determination of Pu in bioassay samples. The present study, reports the utility of 236 Pu and 242 Pu as radiochemical tracers in estimation of Pu in bioassay samples by FTA technique. The advantages of using 236 Pu tracer in FTA over 242 Pu as well as the interference caused due to presence of 241 Pu in the bioassay samples of occupational workers handling power reactor grade Pu is discussed. (author)

  9. Microplate Bioassay for Determining Substrate Selectivity of "Candida rugosa" Lipase

    Science.gov (United States)

    Wang, Shi-zhen; Fang, Bai-shan

    2012-01-01

    Substrate selectivity of "Candida rugosa" lipase was tested using "p"-nitrophenyl esters of increasing chain length (C[subscript 1], C[subscript 7], C[subscript 15]) using the high-throughput screening method. A fast and easy 96-well microplate bioassay was developed to help students learn and practice biotechnological specificity screen. The…

  10. Cytotoxic activity of abietane diterpenoids from roots of Salvia sahendica by HPLC-based activity profiling

    Directory of Open Access Journals (Sweden)

    Fahimeh Moradi-Afrapoli

    Full Text Available ABSTRACT Screening of medicinal plants from Iranian flora against human cancer cell-lines have shown that an hexane extract from roots of Salvia sahendica Boiss. & Buhse, Lamiaceae, is active against human cervical cancer (HeLa and colorectal adenocarcinoma (Caco-2 cell-lines at the test concentration of 100 µg/ml (100% inhibition. Cytotoxicity of the extract was localized with the aid of HPLC-time-based activity profiling adapted to the tetrazolium colorimetric bioassay. Four abietane-type diterpenoids in active time-windows were identified as cytotoxic compounds namely: sahandone (1, sahandol (2, 12-deoxy-salvipisone (3 and sahandinone (4. Compound 1 showed the highest toxicity against HeLa cells (IC50 = 5.6 ± 0.1 µg/ml, which was comparable with betulinic acid (IC50 = 4.3 ± 1.2 µg/ml, the positive control. Compound 2 was active against the HeLa cells (IC50 = 8.9 ± 0.7 µg/ml but not the Caco-2 cell-line. Compounds 1, 3 and 4 exhibited moderate activity (IC50 = 22.9–41.4 µg/ml against the Caco-2 cells. This study reveals that the HeLa cells are more sensitive to all tested compounds than the Caco-2 cells. In silico molecular docking study showed a rigid binding of the compounds to tyrosine kinase pp60src, and proved their cytotoxic activity.

  11. Integrating bioassays and analytical chemistry as an improved approach to support safety assessment of food contact materials.

    Science.gov (United States)

    Veyrand, Julien; Marin-Kuan, Maricel; Bezencon, Claudine; Frank, Nancy; Guérin, Violaine; Koster, Sander; Latado, Hélia; Mollergues, Julie; Patin, Amaury; Piguet, Dominique; Serrant, Patrick; Varela, Jesus; Schilter, Benoît

    2017-10-01

    Food contact materials (FCM) contain chemicals which can migrate into food and result in human exposure. Although it is mandatory to ensure that migration does not endanger human health, there is still no consensus on how to pragmatically assess the safety of FCM since traditional approaches would require extensive toxicological and analytical testing which are expensive and time consuming. Recently, the combination of bioassays, analytical chemistry and risk assessment has been promoted as a new paradigm to identify toxicologically relevant molecules and address safety issues. However, there has been debate on the actual value of bioassays in that framework. In the present work, a FCM anticipated to release the endocrine active chemical 4-nonyphenol (4NP) was used as a model. In a migration study, the leaching of 4NP was confirmed by LC-MS/MS and GC-MS. This was correlated with an increase in both estrogenic and anti-androgenic activities as measured with bioassays. A standard risk assessment indicated that according to the food intake scenario applied, the level of 4NP measured was lower, close or slightly above the acceptable daily intake. Altogether these results show that bioassays could reveal the presence of an endocrine active chemical in a real-case FCM migration study. The levels reported were relevant for safety assessment. In addition, this work also highlighted that bioactivity measured in migrate does not necessarily represent a safety issue. In conclusion, together with analytics, bioassays contribute to identify toxicologically relevant molecules leaching from FCM and enable improved safety assessment.

  12. Compatibility of hydroxypropyl-β-cyclodextrin with algal toxicity bioassays

    International Nuclear Information System (INIS)

    Fai, Patricia Bi; Grant, Alastair; Reid, Brian J.

    2009-01-01

    Numerous reports have indicated that hydrophobic organic compound bioaccessibility in sediment and soil can be determined by extraction using aqueous hydroxypropyl-β-cyclodextrin (HPCD) solutions. This study establishes the compatibility of HPCD with Selenastrum capricornutum and assesses whether its presence influences the toxicity of reference toxicants. Algal growth inhibition (72 h) showed no significant (P > 0.05) difference at HPCD concentrations up to and including 20 mM. HPCD presence did not influence the toxicity of the inorganic reference toxicant (ZnSO 4 ), with IC50 values of 0.82 μM and 0.85 μM, in the presence and absence of HPCD (20 mM), respectively. However, HPCD presence (20 mM) reduced the toxicity of 2,4-dichlorophenol and the herbicides diuron and isoproturon. These reductions were attributed to inclusion complex formation between the toxicants and the HPCD cavity. Liberation of complexed toxicants, by sample manipulation prior to toxicity assessment, is proposed to provide a sensitive, high throughput, bioassay that reflects compound bioaccessibility. - Compatibility of the biomimetic HPCD extraction method with algal cell growth inhibition bioassays to assess toxicity of reference toxicants and environmental relevant herbicides

  13. Compatibility of hydroxypropyl-{beta}-cyclodextrin with algal toxicity bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Fai, Patricia Bi; Grant, Alastair [School of Environmental Sciences, University of East Anglia, Norwich NR4 7TJ (United Kingdom); Reid, Brian J. [School of Environmental Sciences, University of East Anglia, Norwich NR4 7TJ (United Kingdom)], E-mail: b.reid@uea.ac.uk

    2009-01-15

    Numerous reports have indicated that hydrophobic organic compound bioaccessibility in sediment and soil can be determined by extraction using aqueous hydroxypropyl-{beta}-cyclodextrin (HPCD) solutions. This study establishes the compatibility of HPCD with Selenastrum capricornutum and assesses whether its presence influences the toxicity of reference toxicants. Algal growth inhibition (72 h) showed no significant (P > 0.05) difference at HPCD concentrations up to and including 20 mM. HPCD presence did not influence the toxicity of the inorganic reference toxicant (ZnSO{sub 4}), with IC50 values of 0.82 {mu}M and 0.85 {mu}M, in the presence and absence of HPCD (20 mM), respectively. However, HPCD presence (20 mM) reduced the toxicity of 2,4-dichlorophenol and the herbicides diuron and isoproturon. These reductions were attributed to inclusion complex formation between the toxicants and the HPCD cavity. Liberation of complexed toxicants, by sample manipulation prior to toxicity assessment, is proposed to provide a sensitive, high throughput, bioassay that reflects compound bioaccessibility. - Compatibility of the biomimetic HPCD extraction method with algal cell growth inhibition bioassays to assess toxicity of reference toxicants and environmental relevant herbicides.

  14. Methods and applications of HPLC-AMS (WBio 5)

    International Nuclear Information System (INIS)

    Bucholz, B A; Clifford, A J; Duecker, S R; Lin, Y; Vogel, J S

    1999-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a(sup 14)C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the(sup 14)C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the(sup 14)C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of(sup 14)C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected(sup 14)C activity and lt;0.17 Bq (4.5 pCi) on the HPLC column

  15. Estimation of uranium in bioassay samples of occupational workers by laser fluorimetry

    International Nuclear Information System (INIS)

    Suja, A.; Prabhu, S.P.; Sawant, P.D.; Sarkar, P.K.; Tiwari, A.K.; Sharma, R.

    2010-01-01

    A newly established uranium processing facility has been commissioned at BARC, Trombay. Monitoring of occupational workers at regulars intervals is essential to assess intake of uranium by the workers in this facility. The design and engineering safety features of the plant are such that there is very low probability of uranium getting air borne during normal operations. However, the leakages from the system during routine maintenance of the plant may result in intake of uranium by workers. As per the new biokinetic model for uranium, 63% of uranium entering the blood stream gets directly excreted in urine. Therefore, bioassay monitoring (urinalysis) was recommended for these workers. A group of 21 workers was selected for bioassay monitoring to assess the existing urinary excretion levels of uranium before the commencement of actual work. For this purpose, sample collection kit along with an instruction slip was provided to the workers. Bioassay samples received were wet ashed with conc. nitric acid and hydrogen peroxide to break down the metabolized complexes of uranium and it was co-precipitated with calcium phosphate. Separation of uranium from the matrix was done using ion exchange technique and final activity quantification in these samples was done using laser fluorimeter (Quantalase, Model No. NFL/02). Calibration of the laser fluorimeter is done using 10 ppb uranium standard (WHO, France Ref. No. 180000). Verification of the system performance is done by measuring concentration of uranium in the standards (1 ppb to 100 ppb). Standard addition method was followed for estimation of uranium concentration in the samples. Uranyl ions present in the sample get excited by pulsed nitrogen laser at 337.1 nm, and on de-excitation emit fluorescence light (540 nm) intensity which is measured by the PMT. To estimate the uranium in the bioassay samples, a known aliquot of the sample was mixed with 5% sodium pyrophosphate and fluorescence intensity was measured

  16. Methods for conducting bioassays using embryos and larvae of Pacific herring, Clupea pallasi.

    Science.gov (United States)

    Dinnel, Paul A; Middaugh, Douglas P; Schwarck, Nathan T; Farren, Heather M; Haley, Richard K; Hoover, Richard A; Elphick, James; Tobiason, Karen; Marshall, Randall R

    2011-02-01

    The rapid decrease of several stocks of Pacific herring, Clupea pallasi, in Puget Sound, Washington, has led to concerns about the effects of industrial and nonpoint source contamination on the embryo and larval stages of this and related forage fish species. To address these concerns, the state of Washington and several industries have funded efforts to develop embryo and larval bioassay protocols that can be used by commercial laboratories for routine effluent testing. This article presents the results of research to develop herring embryo and larval bioassay protocols. Factors evaluated during protocol development included temperature, salinity, dissolved oxygen (DO), light intensity, photoperiod, larval feeding regimes, use of brine and artificial sea salts, gonad sources, collection methods, and egg quality.

  17. Identification and evaluation of radiolysis products of irradiated chloramphenicol by HPLC-MS and HPLC-DAD

    Energy Technology Data Exchange (ETDEWEB)

    Hong, L; Altorfer, H R [Institute of Pharmaceutical Science, Swiss Federal Institute of Technology (ETH), Zurich (Switzerland); Horni, A; Hesse, M [Institute of Organic Chemistry, University of Zurich, Zurich (Switzerland)

    2005-07-01

    The radiolysis products of chloramphenicol under {gamma}-radiation sterilization were investigated systematically in the present study. Eight main radiolysis products were identified and quantified by HPLC-MS and HPLC-DAD, including two compounds that have never been reported. The minor radiolysis products were quantified, which shows that they are at the concentration levels below the threshold for identification. Carbon-carbon rupture reaction and oxidation reaction were proposed as the main radiolysis reactions of chloramphenicol powder. The applicability of {gamma}-sterilization for chloramphenicol products was quantitatively evaluated with qualitative and quantitative data and the data were compared to the threshold requirements of international regulations for identification. It was concluded that toxicities of the radiolysis products of chloramphenicol produced by {gamma}-radiation sterilization can be neglected, the radiolysis products are safe for human health from chemical view. (author)

  18. Identification and evaluation of radiolysis products of irradiated chloramphenicol by HPLC-MS and HPLC-DAD

    International Nuclear Information System (INIS)

    Hong, L.; Altorfer, H.R.; Horni, A.; Hesse, M.

    2005-01-01

    The radiolysis products of chloramphenicol under γ-radiation sterilization were investigated systematically in the present study. Eight main radiolysis products were identified and quantified by HPLC-MS and HPLC-DAD, including two compounds that have never been reported. The minor radiolysis products were quantified, which shows that they are at the concentration levels below the threshold for identification. Carbon-carbon rupture reaction and oxidation reaction were proposed as the main radiolysis reactions of chloramphenicol powder. The applicability of γ-sterilization for chloramphenicol products was quantitatively evaluated with qualitative and quantitative data and the data were compared to the threshold requirements of international regulations for identification. It was concluded that toxicities of the radiolysis products of chloramphenicol produced by γ-radiation sterilization can be neglected, the radiolysis products are safe for human health from chemical view. (author)

  19. Kinetic microplate bioassays for relative potency of antibiotics improved by partial Least Square (PLS) regression.

    Science.gov (United States)

    Francisco, Fabiane Lacerda; Saviano, Alessandro Morais; Almeida, Túlia de Souza Botelho; Lourenço, Felipe Rebello

    2016-05-01

    Microbiological assays are widely used to estimate the relative potencies of antibiotics in order to guarantee the efficacy, safety, and quality of drug products. Despite of the advantages of turbidimetric bioassays when compared to other methods, it has limitations concerning the linearity and range of the dose-response curve determination. Here, we proposed to use partial least squares (PLS) regression to solve these limitations and to improve the prediction of relative potencies of antibiotics. Kinetic-reading microplate turbidimetric bioassays for apramacyin and vancomycin were performed using Escherichia coli (ATCC 8739) and Bacillus subtilis (ATCC 6633), respectively. Microbial growths were measured as absorbance up to 180 and 300min for apramycin and vancomycin turbidimetric bioassays, respectively. Conventional dose-response curves (absorbances or area under the microbial growth curve vs. log of antibiotic concentration) showed significant regression, however there were significant deviation of linearity. Thus, they could not be used for relative potency estimations. PLS regression allowed us to construct a predictive model for estimating the relative potencies of apramycin and vancomycin without over-fitting and it improved the linear range of turbidimetric bioassay. In addition, PLS regression provided predictions of relative potencies equivalent to those obtained from agar diffusion official methods. Therefore, we conclude that PLS regression may be used to estimate the relative potencies of antibiotics with significant advantages when compared to conventional dose-response curve determination. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Qualitative analysis of MDR-reversing Anastasia Black (Russian black sweet pepper, Capsicum annuum, Solanaceae) extracts and fractions by HPLC and LC-MS-MS methods.

    Science.gov (United States)

    Schelz, Zsuzsanna; Molnár, Joseph; Fogliano, Vincenzo; Ferracane, Rosalia; Pernice, Rita; Shirataki, Yoshiaki; Motohashi, Noboru

    2006-01-01

    In earlier experiments, the MDR (multidrug resistance)-reversal activities of Anastasia Black (Russian black sweet pepper) extracts had been analysed. Recently, the most effective MDR reversing extracts and fractions have been separated by HPLC (high-performance liquid chromatography, for carotenoids) and LC-MS-MS (HPLC combined with mass spectrometry, for phenolic compounds) methods. As a result of the analytical studies, the following flavonoids had been identified: feruloyl glucopyranoside, quercetin rhamnopyranoside glucopyranoside, luteolin glucopyranoside arabinopyranoside, apigenin glucopyranoside arabinopyranoside, quercetin rhamnopyranoside, luteolin arabinopyranoside diglucopy-ranoside, hesperidine and luteolin glucuronide. According to the literature, the aglycones of these phenolic compounds exhibit MDR-reversal activity in vitro, and the connection between the phenolic content of Anastasia Black and MDR-reversal action was therefore studied by different analytical methods. The results of this study revealed that the identified flavonoids of Anastasia Black may be only partially responsible for the modulation of the MDR of mouse lymphoma cells. Other lipophilic compounds, most probably carotenoids, present in Russian black sweet pepper may act as inhibitors of MDR reversal.

  1. [Study on the fingerprint of Morus alba from different habitats by HPLC].

    Science.gov (United States)

    Chen, Cheng; Li, Hong-Bo; Wang, Liu-Ping; Li, Yun-Rong; Xin, Ning

    2012-12-01

    To establish HPLC fingerprint of Morus alba from different habitats by HPLC and provide basis for its quality control. HPLC analysis was performed on an Agilent XDB C18 Column (4.6 mm x 250 mm, 5 microm), gradient eluted composed of acetonitrile and 0.3% phosphate acid. The column temperature was set at 35 degrees C and the flow rate was 0.5 mL/min. The detective wavelength was 290 nm. The HPLC fingerprint for 10 batches of Morus alba was studied on their similarity. There were twelve common peaks in the fingerprint. The similarity of 7 batches was above 0.9 and the other batches had low similarity. The HPLC fingerprint can be used for quality control of Morus alba with high characteristics and specificity.

  2. Abrin Toxicity and Bioavailability after Temperature and pH Treatment.

    Science.gov (United States)

    Tam, Christina C; Henderson, Thomas D; Stanker, Larry H; He, Xiaohua; Cheng, Luisa W

    2017-10-13

    Abrin, one of most potent toxins known to man, is derived from the rosary pea (jequirity pea), Abrus precatorius and is a potential bioterror weapon. The temperature and pH stability of abrin was evaluated with an in vitro cell free translation (CFT) assay, a Vero cell culture cytotoxicity assay, and an in vivo mouse bioassay. pH treatment of abrin had no detrimental effect on its stability and toxicity as seen either in vitro or in vivo. Abrin exposure to increasing temperatures did not completely abrogate protein translation. In both the cell culture cytotoxicity model and the mouse bioassay, abrin's toxic effects were completely abrogated if the toxin was exposed to temperatures of 74 °C or higher. In the cell culture model, 63 °C-treated abrin had a 30% reduction in cytotoxicity which was validated in the in vivo mouse bioassay with all mice dying but with a slight time-to-death delay as compared to the non-treated abrin control. Since temperature inactivation did not affect abrin's ability to inhibit protein synthesis (A-chain), we hypothesize that high temperature treatment affected abrin's ability to bind to cellular receptors (affecting B-chain). Our results confirm the absolute need to validate in vitro cytotoxicity assays with in vivo mouse bioassays.

  3. Enhancing the response of CALUX and CAFLUX cell bioassays for quantitative detection of dioxin-like compounds

    Science.gov (United States)

    ZHAO, Bin; BASTON, David S.; KHAN, Elaine; SORRENTINO, Claudio; DENISON, Michael S.

    2011-01-01

    Reporter genes produce a protein product in transfected cells that can be easily measured in intact or lysed cells and they have been extensively used in numerous basic and applied research applications. Over the past 10 years, reporter gene assays have been widely accepted and used for analysis of 2,3,7,8-tetrachlorodibenzo-p-dioxin and related dioxin-like compounds in various types of matrices, such as biological, environmental, food and feed samples, given that high-resolution instrumental analysis techniques are impractical for large-scale screening analysis. The most sensitive cell-based reporter gene bioassay systems developed are the mechanism-based CALUX (Chemically Activated Luciferase Expression) and CAFLUX (Chemically Activated Fluorescent Expression) bioassays, which utilize recombinant cell lines containing stably transfected dioxin (AhR)-responsive firefly luciferase or enhanced green fluorescent protein (EGFP) reporter genes, respectively. While the current CALUX and CAFLUX bioassays are very sensitive, increasing their lower limit of sensitivity, magnitude of response and dynamic range for chemical detection would significantly increase their utility, particularly for those samples that contain low levels of dioxin-like HAHs (i.e., serum). In this study, we report that the addition of modulators of cell signaling pathways or modification of cell culture conditions results in significant improvement in the magnitude and overall responsiveness of the existing CALUX and CAFLUX cell bioassays. PMID:21394221

  4. Cleavable DNA-protein hybrid molecular beacon: A novel efficient signal translator for sensitive fluorescence anisotropy bioassay.

    Science.gov (United States)

    Hu, Pan; Yang, Bin

    2016-01-15

    Due to its unique features such as high sensitivity, homogeneous format, and independence on fluorescent intensity, fluorescence anisotropy (FA) assay has become a hotspot of study in oligonucleotide-based bioassays. However, until now most FA probes require carefully customized structure designs, and thus are neither generalizable for different sensing systems nor effective to obtain sufficient signal response. To address this issue, a cleavable DNA-protein hybrid molecular beacon was successfully engineered for signal amplified FA bioassay, via combining the unique stable structure of molecular beacon and the large molecular mass of streptavidin. Compared with single DNA strand probe or conventional molecular beacon, the DNA-protein hybrid molecular beacon exhibited a much higher FA value, which was potential to obtain high signal-background ratio in sensing process. As proof-of-principle, this novel DNA-protein hybrid molecular beacon was further applied for FA bioassay using DNAzyme-Pb(2+) as a model sensing system. This FA assay approach could selectively detect as low as 0.5nM Pb(2+) in buffer solution, and also be successful for real samples analysis with good recovery values. Compatible with most of oligonucleotide probes' designs and enzyme-based signal amplification strategies, the molecular beacon can serve as a novel signal translator to expand the application prospect of FA technology in various bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Genotoxicity monitoring of industrial wastes using plant bioassays and management through vermitechnology: A review

    Directory of Open Access Journals (Sweden)

    Sartaj Ahmad Bhat

    2017-10-01

    Full Text Available The main objective of this review was to summarize and present a comprehensive account of the cytotoxic, genotoxic and mutagenic potential of various industrial wastes/sludges using some well-known plant bioassays followed by their bioremediation using vermitechnology. Industries are the main origin of discharges of various types of chemical wastes and are the main causes of environmental degradation. The direct application of industrial sludges could also harm the local biota. The genotoxicity of industrial sludges is assessed using various plant bioassays (for example Allium cepa, Vicia faba and these bioassays are comparatively more sensitive and cost-effective compared to other in-vitro genotoxicity bioassays. In addition, the materials used for toxicity evaluation are easily available and are being routinely used for the monitoring of environmental pollution. In most studies, the increases in root length and mitotic index, as well as the decrease in chromosomal aberrations in post vermicomposted sludges/wastes indicate that earthworms have the ability to reduce the ecotoxicogenetic effects of sludges/wastes. Post vermicompost is considered an excellent material of a homogenous nature as it has reduced levels of contaminants and holds more nutrients over a longer time without affecting the environment. The biotransformation potential of earthworms and their ability to detoxify most of the heavy metals in industrial sludges is because of their strong metabolic system and the involvement of diverse intestinal microflora and chloragocytic cells that reduce toxic forms to nontoxic forms. This unique ability of earthworms confirms the effectiveness of vermitechnology in reducing the toxicity of industrial wastes. Keywords: Allium cepa, Earthworm, Industrial sludge, Toxicity, Vermicomposting

  6. Analysis of the radiochemical purity of 18F-FDG by HPLC

    International Nuclear Information System (INIS)

    Chen Liguang; Tang Anwu; He Shanzhen; Chen Yulong

    2001-01-01

    The radiochemical purity (RCP) of 18 F-FDG is analyzed by HPLC. Eighty-five percent acetonitrile is used as the eluting solution. Carbon hydrate column is used as separation column. The t R of 18 F - is 6.50 min and 18 F-FDG is 9.00 min. HPLC take less time and has higher sensitivity than TLC for the same sample at the same time. So HPLC excels TLC in analyzing RCP of 18 F-FDG

  7. DETERMINATION AND VALIDATION OF MEBHYDROLINE NAPADISYLATE IN TABLETS BY HPLC

    Directory of Open Access Journals (Sweden)

    Lestyo Wulandari

    2010-06-01

    Full Text Available An accurate and sensitive HPLC method has been developed for the determination of mebhydroline napadisylate in the tablet. The Chromatography was performed on a reversed phase C-18 column, using a mobile phase of acetonitrile : ammonia 25% (80 : 20 v/v at ambient temperature 25±5 °C and UV detection operates at 320 nm in an overall analysis time of about 15 min, based on peak area. This HPLC method is selective, precise, and accurate and can be used for routine analysis of pharmaceutical preparation in industrial quality-control laboratories.   Keywords : HPLC, mebhydroline napadisylate, validation

  8. Lanthanide-containing polymer microspheres by multiple-stage dispersion polymerization for highly multiplexed bioassays.

    Science.gov (United States)

    Abdelrahman, Ahmed I; Dai, Sheng; Thickett, Stuart C; Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Winnik, Mitchell A

    2009-10-28

    We describe the synthesis and characterization of metal-encoded polystyrene microspheres by multiple-stage dispersion polymerization with diameters on the order of 2 mum and a very narrow size distribution. Different lanthanides were loaded into these microspheres through the addition of a mixture of lanthanide salts (LnCl(3)) and excess acrylic acid (AA) or acetoacetylethyl methacrylate (AAEM) dissolved in ethanol to the reaction after about 10% conversion of styrene, that is, well after the particle nucleation stage was complete. Individual microspheres contain ca. 10(6)-10(8) chelated lanthanide ions, of either a single element or a mixture of elements. These microspheres were characterized one-by-one utilizing a novel mass cytometer with an inductively coupled plasma (ICP) ionization source and time-of-flight (TOF) mass spectrometry detection. Microspheres containing a range of different metals at different levels of concentration were synthesized to meet the requirements of binary encoding and enumeration encoding protocols. With four different metals at five levels of concentration, we could achieve a variability of 624, and the strategy we report should allow one to obtain much larger variability. To demonstrate the usefulness of element-encoded beads for highly multiplexed immunoassays, we carried out a proof-of-principle model bioassay involving conjugation of mouse IgG to the surface of La and Tm containing particles and its detection by an antimouse IgG bearing a metal-chelating polymer with Pr.

  9. Influence of cAMP on reporter bioassays for dioxin and dioxin-like compounds

    International Nuclear Information System (INIS)

    Kasai, Ayumi; Yao, Jian; Yamauchi, Kozue; Hiramatsu, Nobuhiko; Hayakawa, Kunihiro; Meng, Yiman; Maeda, Shuichiro; Kitamura, Masanori

    2006-01-01

    In reporter assays for detection of dioxins, the dioxin-responsive element (DRE) is generally used as a sensor sequence. In several systems, the CYP1A1 promoter containing DREs (DRE cyp ) is inserted into a part of the long terminal repeat of mouse mammary tumor virus (LTR MMTV ) to improve sensitivity of assays. We found that DRE cyp -LTR MMTV responds not only to dioxins and dioxin-like compounds but also to forskolin, a cAMP-elevating agent. This effect was dose-dependent and reproduced by other cAMP-elevating agents including 8-bromo-cAMP and 3-isobutyl-methylxanthine. The cAMP response element (CRE) and CRE-like sequences were absent in DRE cyp -LTR MMTV and not involved in this process. In contrast to the effect of dioxin, the activation of DRE cyp -LTR MMTV by cAMP was independent of the aryl hydrocarbon receptor (AhR), a ligand-dependent transcription factor for DRE. Furthermore, neither DRE cyp , LTR MMTV nor the consensus sequence of DRE alone was activated in response to cAMP. These data elucidated for the first time that the combination of DRE cyp with LTR MMTV causes a peculiar response to cAMP and suggested that use of AhR antagonists is essential to exclude false-positive responses of DRE cyp -LTR MMTV -based bioassays for detection and quantification of dioxins and dioxin-like compounds

  10. Quantitation of radiolabeled compounds eluting from the HPLC system

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1982-01-01

    Three techniques are compared for the quantitation of various radiolabeled compounds eluting in the high performance liquid chromatography system. The first technique requires fraction-collecting the effluent from the HPLC, removing an aliquot to scintillation vials, and counting each fraction in a liquid scintillation counter. The second uses direct interface of the HPLC effluent to a flow-through radioactivity detector. The third involves quantitation of various radiolabeled compounds (proteins, steroids, and nucleotides) by splitting the effluent from the HPLC with an electronic steam splitter, thus diverting a present portion to the fraction collector for further chemical characterization and the remainder to the radioactivity flow detector for direct quantitation. A direct comparison of the chromatograms and the radioactivity counting efficiencies of these three techniques is presented

  11. Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) as standard fish in bioassays and their reaction to potential reference toxicants

    Energy Technology Data Exchange (ETDEWEB)

    Adelman, I.R.; Smith, L.L. Jr.

    1976-02-01

    Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) were compared for their suitability as standard bioassay fish. Both species showed the same variability of bioassay results when tested with four toxicants. Fathead minnows are recommended on the basis of their small size and on their capability for use in complete life cycle tests. On the basis of minimum variability of bioassay results, sodium chloride was superior for use as a reference toxicant. Both sodium chloride and pentachlorophenol seemed capable of detecting abnormal fish. On the basis of seven listed criteria either sodium chloride or pentachlorophenol would be acceptable as a reference toxicant.

  12. Design and Proof-of-Concept Use of a Circular PMMA Platform with 16-Well Sample Capacity for Microwave-Accelerated Bioassays.

    Science.gov (United States)

    Mohammed, Muzaffer; Aslan, Kadir

    2013-01-01

    We demonstrate the design and the proof-of-concept use of a new, circular poly(methyl methacrylate)-based bioassay platform (PMMA platform), which affords for the rapid processing of 16 samples at once. The circular PMMA platform (5 cm in diameter) was coated with a silver nanoparticle film to accelerate the bioassay steps by microwave heating. A model colorimetric bioassay for biotinylated albumin (using streptavidin-labeled horse radish peroxidase) was performed on the PMMA platform coated with and without silver nanoparticles (a control experiment), and at room temperature and using microwave heating. It was shown that the simulated temperature profile of the PMMA platform during microwave heating were comparable to the real-time temperature profile during actual microwave heating of the constructed PMMA platform in a commercial microwave oven. The model colorimetric bioassay for biotinylated albumin was successfully completed in ~2 min (total assay time) using microwave heating, as compared to 90 min at room temperature (total assay time), which indicates a ~45-fold decrease in assay time. Our PMMA platform design afforded for significant reduction in non-specific interactions and low background signal as compared to non-silvered PMMA surfaces when employed in a microwave-accelerated bioassay carried out in a conventional microwave cavity.

  13. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses

    Energy Technology Data Exchange (ETDEWEB)

    Lange, H.J. de [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands); Centre for Ecosystem Studies, Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA, Wageningen (Netherlands)], E-mail: marieke.delange@wur.nl; Griethuysen, C. van; Koelmans, A.A. [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands)

    2008-01-15

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics. - Change in AVS is a good proxy for sediment disturbance and combined with SEM it can be used as a suitable predictor for biotic effects of sediment contamination.

  14. High performance wash-free magnetic bioassays through microfluidically enhanced particle specificity.

    Science.gov (United States)

    Bechstein, Daniel J B; Lee, Jung-Rok; Ooi, Chin Chun; Gani, Adi W; Kim, Kyunglok; Wilson, Robert J; Wang, Shan X

    2015-06-30

    Magnetic biosensors have emerged as a sensitive and versatile platform for high performance medical diagnostics. These magnetic biosensors require well-tailored magnetic particles as detection probes, which need to give rise to a large and specific biological signal while showing very low nonspecific binding. This is especially important in wash-free bioassay protocols, which do not require removal of particles before measurement, often a necessity in point of care diagnostics. Here we show that magnetic interactions between magnetic particles and magnetized sensors dramatically impact particle transport and magnetic adhesion to the sensor surfaces. We investigate the dynamics of magnetic particles' biomolecular binding and magnetic adhesion to the sensor surface using microfluidic experiments. We elucidate how flow forces can inhibit magnetic adhesion, greatly diminishing or even eliminating nonspecific signals in wash-free magnetic bioassays, and enhancing signal to noise ratios by several orders of magnitude. Our method is useful for selecting and optimizing magnetic particles for a wide range of magnetic sensor platforms.

  15. Theoretische en practische aspecten van het gebruik van micro-HPLC

    NARCIS (Netherlands)

    de Fluiter P; Jansen EHJM

    1992-01-01

    A practical and theoretical approach for the implementation of micro high performance liquid chromatography (HPLC) is described. A new simple and rapid test procedure was developed in wich a HPLC system can be validated for its suitability for micro-bore columns. It appeared that the detector

  16. Eubacterium brachy - Reactivity in In Vitro Bone Resorptive Bioassay,

    Science.gov (United States)

    1983-02-10

    Center Washington, D. C . 20307 If Eubacterium brachy - Reactivity in In Vitro Bone Resorptive Bioassay 1. ABSTRACT Recent studies have demonstrated an...Relative distribution of bacteria at clinically healthy and periodontally diseased sites in humans. J Clin Periodontal 5:115, 1978. 3. Evian, C ...applied foreign protein into rat gingiva. J Periodont Res 6:89, 1971. 21. Gaffer, A., Coleman, E.J., and Marcussen, H.W.: Penetration of dental plaque

  17. [HPLC characteristic fingerprints of sedi linearis herba and sedi herba].

    Science.gov (United States)

    Lu, Lan-Qing; Mei, Qing; Wan, Ding-Rong; Yang, Xin-Zhou; Qiao, Shu; Zhao, Yu-Dan

    2014-04-01

    To study HPLC characteristic fingerprint of Sedum lineare from different harvest periods, and to compare with its related species Sedum sarmentosum. The HPLC fingerprints of Sedum lineare from different collecting periods were established and compared with Sedum sarmentosum by the same detection method. Hyperin, isoquercitrin and astragaloside were identified from the HPLC fingerprint of Sedum lineare. The fingerprint of Sedum lineare growing in the same area but different environment were basically identical; while there were remarkable differences of Sedum lineare growing in the same place but from different harvest periods, with the area of most common peaks changing from little to great, and slightly different peak number. The HPLC fingerprint of the two Sedum species had four common peaks, but could be distinguished from each other. The optimal harvest period of these two species should be full-bloom stage. The established method can provide reference for identification and quality analysis of Sedum lineare.

  18. Continuous flow bioassay method to evaluate the effects of outboard motor exhausts and selected aromatic toxicants on fish. [Carassius auratus

    Energy Technology Data Exchange (ETDEWEB)

    Brenniman, G. (Univ. of Illinois, Chicago); Hartung, R.; Weber, W.J. Jr.

    1976-01-01

    A continuous flow bioassay system was designed to measure the effects of outboard motor exhaust (OME) emissions and selected volatile and evaporative aromatic toxicants on goldfish (Carassius auratus). Continuous flow bioassays were run for 24, 48, 72, 96, and 720 h to determine lethal concentrations for 50 percent of individuals (LC 50's) for leaded OME, non-leaded OME, toluene, xylene, and 1,3,5 trimethylbenzene, the three individual compounds having been identified as significant aromatic components of OME. The 96 h LC-50's for these substances were found to be 171, 168, 23, 17, and 13 ppm, respectively. The values of 171 and 168 ppm for the two OME's are given in terms of gallons of fuel burned per million gallons of water. The continuous flow bioassay method was demonstrated to be a more reliable indicator of the effects of OME pollutants on aquatic organisms than is the static bioassay method.

  19. Assessment of the genotoxicity of 137Cs radiation using Vicia-micronucleus, Tradescantia-micronucleus and Tradescantia-stamen-hair mutation bioassays.

    Science.gov (United States)

    Minouflet, Marion; Ayrault, Sophie; Badot, Pierre-Marie; Cotelle, Sylvie; Ferard, Jean-François

    2005-01-01

    Since the middle of the 20th century, ionizing radiations from radioactive isotopes including 137Cs have been investigated to determine their genotoxic impact on living organisms. The present study was designed to compare the effectiveness of three plant bioassays to assess DNA damage induced by low doses of 137Cs: Vicia-micronucleus test (Vicia-MCN), Tradescantia-micronucleus test (Trad-MCN) and Tradescantia-stamen-hair mutation test (Trad-SH) were used. Vicia faba (broad bean) and Tradescantia clone 4430 (spiderwort) were exposed to 137Cs according to different scenarios: external and internal (contamination) irradiations. Experiments were conducted with various levels of radioactivity in solution or in soil, using solid or liquid 137Cs sources. The three bioassays showed different sensitivities to the treatments. Trad-MCN appeared to be the most sensitive test (significative response from 1.5 kBq/200 ml after 30 h of contamination). Moreover, at comparable doses, internal irradiations led to larger effects for the three bioassays. These bioassays are effective tests for assessing the genotoxic effects of radioactive 137Cs pollution.

  20. Assessment of the genotoxicity of 137Cs radiation using Vicia-micronucleus, Tradescantia-micronucleus and Tradescantia-stamen-hair mutation bioassays

    International Nuclear Information System (INIS)

    Minouflet, Marion; Ayrault, Sophie; Badot, Pierre-Marie; Cotelle, Sylvie; Ferard, Jean-Francois

    2005-01-01

    Since the middle of the 20th century, ionizing radiations from radioactive isotopes including 137 Cs have been investigated to determine their genotoxic impact on living organisms. The present study was designed to compare the effectiveness of three plant bioassays to assess DNA damage induced by low doses of 137 Cs: Vicia-micronucleus test (Vicia-MCN), Tradescantia-micronucleus test (Trad-MCN) and Tradescantia-stamen-hair mutation test (Trad-SH) were used. Vicia faba (broad bean) and Tradescantia clone 4430 (spiderwort) were exposed to 137 Cs according to different scenarios: external and internal (contamination) irradiations. Experiments were conducted with various levels of radioactivity in solution or in soil, using solid or liquid 137 Cs sources. The three bioassays showed different sensitivities to the treatments. Trad-MCN appeared to be the most sensitive test (significative response from 1.5 kBq/200 ml after 30 h of contamination). Moreover, at comparable doses, internal irradiations led to larger effects for the three bioassays. These bioassays are effective tests for assessing the genotoxic effects of radioactive 137 Cs pollution

  1. [HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].

    Science.gov (United States)

    Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan

    2014-11-01

    To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.

  2. Bioassay directed identification of natural aryl hydrocarbon-receptor agonists in marmalade

    NARCIS (Netherlands)

    Ede, van K.I.; Li, A.; Antunes Fernandes, E.C.; Mulder, P.P.J.; Peijnenburg, A.A.C.M.; Hoogenboom, L.A.P.

    2008-01-01

    Citrus fruit and citrus fruit products, like grapefruit, lemon and marmalade were shown to contain aryl hydrocarbon receptor (AhR) agonists, as detected with the DR CALUX® bioassay. This is of interest regarding the role of the Ah-receptor pathway in the adverse effects of dioxins, PCBs and other

  3. Guidance document for prepermit bioassay testing of low-level radioactive waste

    International Nuclear Information System (INIS)

    Anderson, S.L.; Harrison, F.L.

    1990-11-01

    In response to the mandate of Public Law 92-532, the Marine Protection, Research, and Sanctuaries Act (MPRSA) of 1972, as amended, the Environmental Protection Agency (EPA) has developed a program to promulgate regulations and criteria to control the ocean disposal of radioactive wastes. The EPA seeks to understand the mechanisms for biological response of marine organisms to the low levels of radioactivity that may arise from the release of these wastes as a result of ocean-disposal practices. Such information will play an important role in determining the adequacy of environmental assessments provided to the EPA in support of any disposal permit application. Although the EPA requires packaging of low-level radioactive waste to prevent release during radiodecay of the materials, some release of radioactive material into the deep-sea environment may occur when a package deteriorates. Therefore, methods for evaluating the impact on biota are being evaluated. Mortality and phenotypic responses are not anticipated at the expected low environmental levels that might occur if radioactive materials were released from the low-level waste packages. Therefore, traditional bioassay systems are unsuitable for assessing sublethal effects on biota in the marine environment. The EPA Office of Radiation Programs (ORP) has had an ongoing program to examine sublethal responses to radiation at the cellular level, using cytogenetic end points. This technical guidance report represents prepermit bioassay procedures that potentially may be applicable to the assessment of effects from a mixture of radionuclides that could be released from a point source at the ocean bottom. Methodologies along with rationale and a discussion of uncertainty are presented for the sediment benthic bioassay protocols identified in this report

  4. GHSI emergency radionuclide bioassay laboratory network - summary of the second exercise

    International Nuclear Information System (INIS)

    Li, Chunsheng; Ko, Raymond; Quayle, Debora; Sadi, Baki; Bartizel, Christine; Battisti, Paolo; Boettger, Axel; Bouvier, Celine; Paquet, Francois; CapoteCuellar, Antonio; Carr, Zhanat; Hammond, Derek; Hartmann, Martina; Heikkinen, Tarja; Jones, Robert L.; Kim, Eunjoo; Koga, Roberto; Kukhta, Boris; Mitchell, Lorna; Morhard, Ryan; Rulik, Petr; Sergei, Aleksanin; Sierra, Inmaculada; Oliveira Sousa, Wandersonde; Szabo, Gyula

    2017-01-01

    The Global Health Security Initiative (GHSI) established a laboratory network within the GHSI community to develop collective surge capacity for radionuclide bioassay in response to a radiological or nuclear emergency as a means of enhancing response capability, health outcomes and community resilience. GHSI partners conducted an exercise in collaboration with the WHO Radiation Emergency Medical Preparedness and Assistance Network and the IAEA Response and Assistance Network, to test the participating laboratories (18) for their capabilities in in vitro assay of biological samples, using a urine sample spiked with multiple high-risk radionuclides ( 90 Sr, 106 Ru, 137 Cs, and 239 Pu). Laboratories were required to submit their reports within 72 h following receipt of the sample, using a pre-formatted template, on the procedures, methods and techniques used to identify and quantify the radionuclides in the sample, as well as the bioassay results with a 95% confidence interval. All of the participating laboratories identified and measured all or some of the radionuclides in the sample. However, gaps were identified in both the procedures used to assay multiple radionuclides in one sample, as well as in the methods or techniques used to assay specific radionuclides in urine. Two-third of the participating laboratories had difficulties in determining all the radionuclides in the sample. Results from this exercise indicate that challenges remain with respect to ensuring that results are delivered in a timely, consistent and reliable manner to support medical interventions. Laboratories within the networks are encouraged to work together to develop and maintain collective capabilities and capacity for emergency bioassay, which is an important component of radiation emergency response. (authors)

  5. Guidance document for prepermit bioassay testing of low-level radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, S.L.; Harrison, F.L.

    1990-11-01

    In response to the mandate of Public Law 92-532, the Marine Protection, Research, and Sanctuaries Act (MPRSA) of 1972, as amended, the Environmental Protection Agency (EPA) has developed a program to promulgate regulations and criteria to control the ocean disposal of radioactive wastes. The EPA seeks to understand the mechanisms for biological response of marine organisms to the low levels of radioactivity that may arise from the release of these wastes as a result of ocean-disposal practices. Such information will play an important role in determining the adequacy of environmental assessments provided to the EPA in support of any disposal permit application. Although the EPA requires packaging of low-level radioactive waste to prevent release during radiodecay of the materials, some release of radioactive material into the deep-sea environment may occur when a package deteriorates. Therefore, methods for evaluating the impact on biota are being evaluated. Mortality and phenotypic responses are not anticipated at the expected low environmental levels that might occur if radioactive materials were released from the low-level waste packages. Therefore, traditional bioassay systems are unsuitable for assessing sublethal effects on biota in the marine environment. The EPA Office of Radiation Programs (ORP) has had an ongoing program to examine sublethal responses to radiation at the cellular level, using cytogenetic end points. This technical guidance report represents prepermit bioassay procedures that potentially may be applicable to the assessment of effects from a mixture of radionuclides that could be released from a point source at the ocean bottom. Methodologies along with rationale and a discussion of uncertainty are presented for the sediment benthic bioassay protocols identified in this report.

  6. Review of Bioassays for Monitoring Fate and Transport ofEstrogenic Endocrine Disrupting Compounds in Water

    Energy Technology Data Exchange (ETDEWEB)

    CGCampbell@lbl.gov

    2004-01-30

    Endocrine disrupting compounds (EDCs) are recognizedcontaminants threatening water quality. Despite efforts in sourceidentification, few strategies exist for characterization or treatment ofthis environmental pollution. Given that there are numerous EDCs that cannegatively affect humans and wildlife, general screening techniques likebioassays and biosensors provide an essential rapid and intensiveanalysis capacity. Commonly applied bioassays include the ELISA and YESassays, but promising technologies include ER-CALUXa, ELRA, Endotecta,RIANA, and IR-bioamplification. Two biosensors, Endotecta and RIANA, arefield portable using non-cellular biological detection strategies.Environmental management of EDCs in water requires integration ofbiosensors and bioassays for monitoring and assessment.

  7. Electrochemically Pretreated Carbon Microfiber Electrodes as Sensitive HPLC-EC Detectors

    Directory of Open Access Journals (Sweden)

    Zdenka Bartosova

    2012-01-01

    Full Text Available The paper focuses on the analysis and detection of electroactive compounds using high-performance liquid chromatography (HPLC combined with electrochemical detection (EC. The fabrication and utilization of electrochemically treated carbon fiber microelectrodes (CFMs as highly sensitive amperometric detectors in HPLC are described. The applied pretreatment procedure is beneficial for analytical characteristics of the sensor as demonstrated by analysis of the model set of phenolic acids. The combination of CFM with separation power of HPLC technique allows for improved detection limits due to unique electrochemical properties of carbon fibers. The CFM proved to be a promising tool for amperometric detection in liquid chromatography.

  8. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  9. Development of acute and chronic sediment bioassays with the harpacticoid copepod Quinquelaophonte sp.

    Science.gov (United States)

    Stringer, Tristan J; Glover, Chris N; Keesing, Vaughan; Northcott, Grant L; Gaw, Sally; Tremblay, Louis A

    2014-01-01

    Reliable environmentally realistic bioassay methodologies are increasingly needed to assess the effects of environmental pollution. This study describes two estuarine sediment bioassays, one acute (96 h) and one chronic (14 d), with the New Zealand harpacticoid copepod Quinquelaophonte sp. utilising behavioural and reproductive endpoints. Spiked sediments were used to expose Quinquelaophonte sp. to three reference compounds representing important categories of estuarine chemical stressors: zinc (a metal), atrazine (a pesticide), and phenanthrene (a polycyclic aromatic hydrocarbon). Acute-to-chronic ratios (ACR) were used to further characterise species responses. Acute sediment (sandy and low total organic content) 96 h EC50 values for the sublethal inhibition of mobility for zinc, atrazine and phenanthrene were 137, 5.4, and 2.6 µg/g, respectively. The chronic EC50 values for inhibition of reproduction (total offspring) were 54.5, 0.0083, and 0.067 µg/g for zinc, atrazine, and phenanthrene, respectively. For phenanthrene, a potentially novel mode of action was identified on reproduction. Quinquelaophonte sp. was found to be more sensitive than several other estuarine species indicating choice of test organism is important to characterising the effects of environmentally relevant levels of contamination. The bioassay sediment results demonstrate the sensitivity and suitability of Quinquelaophonte sp. as a tool for the assessment use of estuarine health. © 2013 Published by Elsevier Inc.

  10. Intestinal antispasmodic effects of Helichrysum italicum (Roth) Don ssp. italicum and chemical identification of the active ingredients.

    Science.gov (United States)

    Rigano, Daniela; Formisano, Carmen; Senatore, Felice; Piacente, Sonia; Pagano, Ester; Capasso, Raffaele; Borrelli, Francesca; Izzo, Angelo A

    2013-12-12

    In the Mediterranean Area, the flowers of Helichrysum italicum ssp. italicum are a traditional remedy for the treatment of intestinal complaints and are used as herbal tea for curing digestive, stomachic and intestinal diseases. In order to find scientific evidence for the traditional utilization of this plant, the effect of an ethanolic extract of Helichrysum italicum was investigated by using in vivo and in vitro experimental models. Then, through bioassay-guided fractionation procedures, active component(s) were identified. Contractility in vitro was evaluated by stimulating the isolated ileum, in an organ bath, with acetylcholine and barium chloride; motility in vivo was evaluated by measuring upper gastrointestinal transit, both in control mice and in mice with experimental intestinal inflammation induced by croton oil. Chromatographic separation techniques such as HPLC and silica gel columns have yielded the active principles of Helichrysum italicum. We found that the ethanolic extract of Helichrysum italicum ssp. italicum flowers elicited antispasmodic actions in the isolated mouse ileum and inhibited transit preferentially in the inflamed gut. A bioassay guided fractionation of the extract yielded the known compounds 12-acetoxytremetone (1) and 2,3-dihydro-2-[1-(hydroxymethyl)ethenyl]-5-benzofuranyl]-ethanone (2). Present study supported the traditional use of Helichrysum italicum ssp. italicum flowers for intestinal complaints and through bioassay-guided fractionation procedures from the crude extract we showed that 12-acetoxytremetone (1) and 2,3-dihydro-2-[1-(hydroxymethyl)ethenyl]-5-benzofuranyl]-ethanone (2) acted in a synergistic way to produce an intestinal antispasmodic effect. © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. [Determination of rhynchophylline and isorhynchophylline in Uncaria rhynchophylla by HPLC].

    Science.gov (United States)

    Yang, Xiu-Juan; Hong, Yan-Long; Wu, Fei; Ruan, Ke-Feng; Feng, Yi

    2013-03-01

    To explore an HPLC method for determination of rhnchophylline and isorhnchophylline in Uncaria rhnchophylla. An HPLC method has been developed for determination of rhnchophylline and isorhnchophylline. The transformation of rhnchophylline and isorhnchophylline after heating was also studied by HPLC-ESI-MS. Good linearities of rhynchophylline and isorhynchophylline were 0.064-5.100, 0.064-5.110 mg, respectively. The average recoveries were from 87.51% to 88.83% for rhynchophylline and from 107.9% to 113.9% for isorhynchophylline. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 12.60% and 40.00% in the reflux extraction procedure, respectively. While in the ultrasonic extraction procedure, the average recoveries of rhynchophylline and isorhynchophylline was from 99.48% to 103.2% and from 97.00% to 99.59%, resepectively. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 47.08% and 51.03%, respectively. The unqualified recovery could be elucidated by HPLC-ESI-MS analysis, indicating that trhynchophylline could be transformed mostly into isorhynchophylline and a little amount of unkown composition, while isorhynchophylline could be transformed into rhynchophylline isocorynoxeine, corynoxeine and 22-O-beta-D-glucopyranosyl isocorynoxeinic acid during the extraction procedure. Ultrasonic extraction procedure was more sutble for HPLC determination of the content of rhynchophylline and isorhynchophylline in U. rhnchophylla, however, the recovery problems should be paid attention to when it comes to the determination.

  12. Determination of anthocyanins from camu-camu (Myrciaria dubia) by HPLC-PDA, HPLC-MS, and NMR.

    Science.gov (United States)

    Zanatta, Cinthia Fernanda; Cuevas, Elyana; Bobbio, Florinda O; Winterhalter, Peter; Mercadante, Adriana Z

    2005-11-30

    Camu-camu [Myrciaria dubia (HBK) McVaugh] is a small fruit native to the Amazonian rain forest. Its anthocyanin profile has now been investigated for the first time. Fruits from two different regions of the São Paulo state, Brazil, were analyzed. The major anthocyanins were isolated by high-speed countercurrent chromatography. HPLC-PDA, HPLC-MS/MS, and 1H NMR were used to confirm the identity of the main anthocyanins of camu-camu. Cyanidin-3-glucoside was identified as the major pigment in the fruits from both regions, representing 89.5% in the fruits produced in Iguape and 88.0% in those from Mirandópolis, followed by the delphinidin-3-glucoside, ranging between 4.2 and 5.1%, respectively. Higher total anthocyanin contents were detected in the fruits from Iguape (54.0 +/- 25.9 mg/100 g) compared to those from Mirandópolis (30.3 +/- 6.8 mg/100 g), most likely because of the lower temperatures in the Iguape region.

  13. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  14. In vitro metabolism studies of 18F-labeled 1-phenylpiperazine using mouse liver S9 fraction

    International Nuclear Information System (INIS)

    Ryu, Eun Kyoung; Choe, Yearn Seong; Kim, Dong Hyun; Ko, Bong-Ho; Choi, Yong; Lee, Kyung-Han; Kim, Byung-Tae

    2006-01-01

    The in vitro metabolism of 1-(4-[ 18 F]fluoromethylbenzyl)-4-phenylpiperazine ([ 18 F]1) and 1-(4-[ 18 F]fluorobenzyl)-4-phenylpiperazine ([ 18 F]2) was investigated using mouse liver S9 fraction. Results were compared to those of in vivo metabolism using mouse blood and bone and to in vitro metabolism using mouse liver microsomes. Defluorination was the main metabolic pathway for [ 18 F]1 in vitro and in vivo. Based on TLC, HPLC and LC-MS data, [ 18 F]fluoride ion and less polar radioactive metabolites derived from aromatic ring oxidation were detected in vitro, and the latter metabolites were rapidly converted into the former with time, whereas only the [ 18 F]fluoride ion was detected in vivo. Similarly, the in vitro metabolism of [ 18 F]2 using either S9 fraction or microsomes showed the same pattern as the in vivo method using blood; however, the radioactive metabolites derived from aromatic ring oxidation were not detected in vivo. These results demonstrate that liver S9 fraction can be widely used to investigate the intermediate radioactive metabolites and to predict the in vivo metabolism of radiotracers

  15. Transfusion Associated Peak in Hb HPLC Chromatogram – a Case Report

    Science.gov (United States)

    Jain, Sonal; Dass, Jasmita; Pati, Hara Prasad

    2012-01-01

    High performance liquid chromatography (HPLC) and electrophoresis are commonly used to diagnose various hemoglobinopathies. However, insufficient information about the transfusion history can lead to unexpected and confusing results. We are reporting a case of Juvenile myelomonocytic leukemia (JMML) in which HbHPLC was done to quantify fetal hemoglobin (HbF). The chromatogram showed elevated HbF along with a peak in the HbD window. A transfusion acquired peak was suspected based on the unexpectedly low percentage of HbD and was subsequently confirmed using parental HbHPLC. PMID:22348188

  16. Brine shrimp bioassay: importance of correct taxonomic identification of Artemia (Anostraca) species.

    Science.gov (United States)

    Ruebhart, David R; Cock, Ian E; Shaw, Glen R

    2008-08-01

    Despite the common use of the brine shrimp bioassay in toxicology, there is confusion in the literature regarding citation of the correct taxonomic identity of the Artemia species used. The genus Artemia, once thought to be represented by a single species Artemia salina, is now known to be composed of several bisexual species as well as parthenogenetic populations. Artemia franciscana is the best studied of the Artemia species and is considered to represent the vast majority of studies in which Artemia is used as an experimental test organism. We found that in studies referring to the use of A. salina, the zoogeography of the cyst harvest site indicated that the species used was actually A. franciscana. Those performing bioassays with Artemia need to exercise diligence in assigning correct species identification, as the identity of the test organism is an important parameter in assuring the validity of the results of the assay.

  17. The ICRP working party on bioassay interpretation

    International Nuclear Information System (INIS)

    Fry, F.A.; Lipsztein, J.L.; Birchall, A.

    2003-01-01

    In recent years there have been many developments in modelling the behaviour of radionuclides in the human body. The current generation of models are designed to be more 'realistic' than the previous generation of simple compartment models. The International Commission on Radiological Protection (ICRP) uses these models to produce dose coefficients and recognises that there is a need to give more guidance on how these models can be used to interpret bioassay data. A working party has been set up to address the issue. This paper describes some of the problems, some approaches to solving the problems and the progress of the ICRP working party. (author)

  18. Sediment toxicity assessment in the Lagoon of Venice (Italy) using Paracentrotus lividus (Echinodermata: Echinoidea) fertilization and embryo bioassays.

    Science.gov (United States)

    Volpi Ghirardini, A; Arizzi Novelli, A; Tagliapietra, D

    2005-09-01

    The capacity of two toxicity bioassays (fertilization and embryo toxicity tests) to discriminate sediment toxicity using the sea urchin Paracentrotus lividus was tested in five stations with different levels of pollution in the Lagoon of Venice. Two stations were located in estuarine sites, two in the industrial zone, and one in a site at the top of our quality gradient (reference). Elutriate was chosen as sediment matrix to assess the potential effects of bioavailable pollutants in the water column as a consequence of sediment resuspension (dredging and dumping, fishing gear, etc.). An experimental design based on Quality Assurance/Quality Control procedures (QA/QC) was adopted in order to set the methodological basis for an effective use of these bioassays in monitoring programs. Results revealed both higher embriotoxicity than spermiotoxicity in all stations and the efficacy of combined use of both toxicity bioassays in discriminating differing pollution/bioavailability between stations and periods. The good representativeness of the integrated sampling scheme and the standardization of all experimental phases yielded high precision of results. Clear Toxicity Fingerprints were evidenced for the investigated sites through the combined use of both bioassays. A good fit between ecotoxicological data and chemical contamination levels was found, except for unnatural sediment texture.

  19. Separation, purification and identification of flavonoid glycosides using reversed phase hplc

    International Nuclear Information System (INIS)

    Hasan, A.; Khan, M.A.

    2002-01-01

    Optimal high performance liquid chromatography (HPLC) separation conditions and semi-preparative scale isolation of flavonoid glycosides from three plant species namely Vitex nagunda, Rubus ulmifolious and Malotus philipensis is reported. Identification of purified flavonoid glycoside was achieved using spiking technique in HPLC. (author)

  20. A new approach for bioassays based on frequency- and time-domain measurements of magnetic nanoparticles.

    Science.gov (United States)

    Oisjöen, Fredrik; Schneiderman, Justin F; Astalan, Andrea Prieto; Kalabukhov, Alexey; Johansson, Christer; Winkler, Dag

    2010-01-15

    We demonstrate a one-step wash-free bioassay measurement system capable of tracking biochemical binding events. Our approach combines the high resolution of frequency- and high speed of time-domain measurements in a single device in combination with a fast one-step bioassay. The one-step nature of our magnetic nanoparticle (MNP) based assay reduces the time between sample extraction and quantitative results while mitigating the risks of contamination related to washing steps. Our method also enables tracking of binding events, providing the possibility of, for example, investigation of how chemical/biological environments affect the rate of a binding process or study of the action of certain drugs. We detect specific biological binding events occurring on the surfaces of fluid-suspended MNPs that modify their magnetic relaxation behavior. Herein, we extrapolate a modest sensitivity to analyte of 100 ng/ml with the present setup using our rapid one-step bioassay. More importantly, we determine the size-distributions of the MNP systems with theoretical fits to our data obtained from the two complementary measurement modalities and demonstrate quantitative agreement between them. Copyright 2009 Elsevier B.V. All rights reserved.

  1. Comparative performances of eggs and embryos of sea urchin (Paracentrotus lividus) in toxicity bioassays used for assessment of marine sediment quality.

    Science.gov (United States)

    Khosrovyan, A; Rodríguez-Romero, A; Salamanca, M J; Del Valls, T A; Riba, I; Serrano, F

    2013-05-15

    The potential toxicity of sediments from various ports was assessed by means of two different liquid-phase toxicity bioassays (acute and chronic) with embryos and eggs of sea urchin Paracentrotus lividus. Performances of embryos and eggs of P. lividus in these bioassays were compared for their interchangeable applicability in integrated sediment quality assessment. The obtained endpoints (percentages of normally developed plutei and fertilized eggs) were linked to physical and chemical properties of sediments and demonstrated dependence on sediment contamination. The endpoints in the two bioassays were strongly correlated and generally exhibited similar tendency throughout the samples. Therein, embryos demonstrated higher sensitivity to elutriate exposure, compared to eggs. It was concluded that these tests could be used interchangeably for testing toxicity of marine sediments. Preferential use of any of the bioassays can be determined by the discriminatory capacity of the test or vulnerability consideration of the test subject to the surrounding conditions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Abrin Toxicity and Bioavailability after Temperature and pH Treatment

    Directory of Open Access Journals (Sweden)

    Christina C. Tam

    2017-10-01

    Full Text Available Abrin, one of most potent toxins known to man, is derived from the rosary pea (jequirity pea, Abrus precatorius and is a potential bioterror weapon. The temperature and pH stability of abrin was evaluated with an in vitro cell free translation (CFT assay, a Vero cell culture cytotoxicity assay, and an in vivo mouse bioassay. pH treatment of abrin had no detrimental effect on its stability and toxicity as seen either in vitro or in vivo. Abrin exposure to increasing temperatures did not completely abrogate protein translation. In both the cell culture cytotoxicity model and the mouse bioassay, abrin’s toxic effects were completely abrogated if the toxin was exposed to temperatures of 74 °C or higher. In the cell culture model, 63 °C-treated abrin had a 30% reduction in cytotoxicity which was validated in the in vivo mouse bioassay with all mice dying but with a slight time-to-death delay as compared to the non-treated abrin control. Since temperature inactivation did not affect abrin’s ability to inhibit protein synthesis (A-chain, we hypothesize that high temperature treatment affected abrin’s ability to bind to cellular receptors (affecting B-chain. Our results confirm the absolute need to validate in vitro cytotoxicity assays with in vivo mouse bioassays.

  3. An Investigation Into HPLC Data Quality Problems

    Science.gov (United States)

    Hooker, Stanford B.; VanHeukelem, Laurie

    2011-01-01

    This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."

  4. Polycyclic aromatic hydrocarbons bioavailability in industrial and agricultural soils: Linking SPME and Tenax extraction with bioassays.

    Science.gov (United States)

    Guo, Meixia; Gong, Zongqiang; Li, Xiaojun; Allinson, Graeme; Rookes, James; Cahill, David

    2017-06-01

    The aims of this study were to evaluate the bioavailability of polycyclic aromatic hydrocarbons (PAHs) in industrial and agricultural soils using chemical methods and a bioassay, and to study the relationships between the methods. This was conducted by comparing the quantities of PAHs extracted from two manufactured gas plant (MGP) soils and an agricultural soil with low level contamination by solid-phase micro-extraction (SPME) and Tenax-TA extraction with the quantities taken up by the earthworm (Eisenia fetida). In addition, a biodegradation experiment was conducted on one MGP soil (MGP-A) to clarify the relationship between PAH removal by biodegradation and the variation in PAH concentrations in soil pore water. Results demonstrated that the earthworm bioassay could not be used to examine PAH bioavailability in the tested MGP soils; which was the case even in the diluted MGP-A soils after biodegradation. However, the bioassay was successfully applied to the agricultural soil. These results suggest that earthworms can only be used for bioassays in soils with low toxicity. In general, rapidly desorbing concentrations extracted by Tenax-TA could predict PAH concentrations accumulated in earthworms (R 2 =0.66), while SPME underestimated earthworm concentrations by a factor of 2.5. Both SPME and Tenax extraction can provide a useful tool to predict PAH bioavailability for earthworms, but Tenax-TA extraction was proven to be a more sensitive and precise method than SPME for the prediction of earthworm exposure in the agricultural soil. Copyright © 2017. Published by Elsevier Inc.

  5. Size exclusion HPLC of proteins for evaluation of durum wheat quality

    Science.gov (United States)

    The present research aimed to assess size exclusion HPLC (SE-HPLC) in protein molecular weight distribution determination for quality evaluation of durum semolina. Semolina samples were milled from 13 durum genotypes grown at 7 locations in 2009 and 2010 in ND. Sodium dodecyl sulfate (SDS) buffer ...

  6. Chemical Differentiation of Dendrobium officinale and Dendrobium devonianum by Using HPLC Fingerprints, HPLC-ESI-MS, and HPTLC Analyses

    Science.gov (United States)

    Ye, Zi; Dai, Jia-Rong; Zhang, Cheng-Gang; Lu, Ye; Wu, Lei-Lei; Gong, Amy G. W.; Wang, Zheng-Tao

    2017-01-01

    The stems of Dendrobium officinale Kimura et Migo (Dendrobii Officinalis Caulis) have a high medicinal value as a traditional Chinese medicine (TCM). Because of the limited supply, D. officinale is a high priced TCM, and therefore adulterants are commonly found in the herbal market. The dried stems of a closely related Dendrobium species, Dendrobium devonianum Paxt., are commonly used as the substitute; however, there is no effective method to distinguish the two Dendrobium species. Here, a high performance liquid chromatography (HPLC) method was successfully developed and applied to differentiate D. officinale and D. devonianum by comparing the chromatograms according to the characteristic peaks. A HPLC coupled with electrospray ionization multistage mass spectrometry (HPLC-ESI-MS) method was further applied for structural elucidation of 15 flavonoids, 5 phenolic acids, and 1 lignan in D. officinale. Among these flavonoids, 4 flavonoid C-glycosides were firstly reported in D. officinale, and violanthin and isoviolanthin were identified to be specific for D. officinale compared with D. devonianum. Then, two representative components were used as chemical markers. A rapid and reliable high performance thin layer chromatography (HPTLC) method was applied in distinguishing D. officinale from D. devonianum. The results of this work have demonstrated that these developed analytical methods can be used to discriminate D. officinale and D. devonianum effectively and conveniently. PMID:28769988

  7. Estimation of uranium in bioassay samples of occupational workers by laser fluorimetry

    International Nuclear Information System (INIS)

    Suja, A.; Prabhu, S.P.; Sawant, P.D.; Sarkar, P.K.; Tiwari, A.K.; Sharma, R.

    2012-01-01

    A newly established uranium processing facility has been commissioned at BARC, Trombay. Monitoring of occupational workers is essential to assess intake of uranium in this facility. A group of 21 workers was selected for bioassay monitoring to assess the existing urinary excretion levels of uranium before the commencement of actual work. Bioassay samples collected from these workers were analyzed by ion-exchange technique followed by laser fluorimetry. Standard addition method was followed for estimation of uranium concentration in the samples. The minimum detectable activity by this technique is about 0.2 ng. The range of uranium observed in these samples varies from 19 to 132 ng/L. Few of these samples were also analyzed by fission track analysis technique and the results were found to be comparable to those obtained by laser fluorimetry. The urinary excretion rate observed for the individual can be regarded as a 'personal baseline' and will be treated as the existing level of uranium in urine for these workers at the facility. (author)

  8. Comparative study of Graves' ophthalmopathy by ultrasonography, computed tomography, and fish bioassay

    International Nuclear Information System (INIS)

    Mann, K.; Schoener, W.; Juengst, D.; Karl, H.J.; Maier-Hauff, K.; Rothe, R.

    1979-01-01

    In 35 patients with Graves' ophthalmopathy (GO) thyroid function was tested by T 3 -RIA, T 4 -RIA, TBI, TRH-test, thyroid scanning, and determination of thyroid autoantibodies. Additional ultrasonography (A-scan), computed tomography (CT) of the orbit, and the determination of an exophthalmogenic serum activity in fish bioassay was performed. Typical alterations for GO were observed in 26 cases with ultrasonography. CT showed an enlargement of medial and/or lateral rectus muscles in 24 of 33 patients, and in 17 cases a region of high density in the apex of the muscle cone. The density of retrobulbar fat after i.v. injection of contrast medium did not differ significantly from that observed in normal men. Characteristic signs of GO were not detected in only 2 cases using both methods together. Exophthalmogenic serum activity was found in the IgG fraction of serum protein. The incidence rate was high (69%), but for diagnostic purpose the fish bioassay cannot be recommended. (orig.) 891 AJ/orig. 892 BRE [de

  9. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Effect-based trigger values for in vitro bioassays: Reading across from existing water quality guideline values.

    Science.gov (United States)

    Escher, Beate I; Neale, Peta A; Leusch, Frederic D L

    2015-09-15

    Cell-based bioassays are becoming increasingly popular in water quality assessment. The new generations of reporter-gene assays are very sensitive and effects are often detected in very clean water types such as drinking water and recycled water. For monitoring applications it is therefore imperative to derive trigger values that differentiate between acceptable and unacceptable effect levels. In this proof-of-concept paper, we propose a statistical method to read directly across from chemical guideline values to trigger values without the need to perform in vitro to in vivo extrapolations. The derivation is based on matching effect concentrations with existing chemical guideline values and filtering out appropriate chemicals that are responsive in the given bioassays at concentrations in the range of the guideline values. To account for the mixture effects of many chemicals acting together in a complex water sample, we propose bioanalytical equivalents that integrate the effects of groups of chemicals with the same mode of action that act in a concentration-additive manner. Statistical distribution methods are proposed to derive a specific effect-based trigger bioanalytical equivalent concentration (EBT-BEQ) for each bioassay of environmental interest that targets receptor-mediated toxicity. Even bioassays that are indicative of the same mode of action have slightly different numeric trigger values due to differences in their inherent sensitivity. The algorithm was applied to 18 cell-based bioassays and 11 provisional effect-based trigger bioanalytical equivalents were derived as an illustrative example using the 349 chemical guideline values protective for human health of the Australian Guidelines for Water Recycling. We illustrate the applicability using the example of a diverse set of water samples including recycled water. Most recycled water samples were compliant with the proposed triggers while wastewater effluent would not have been compliant with a few

  11. Use of a modified microplate bioassay method to investigate antibacterial activity in the Peruvian medicinal plant Peperomia galioides.

    Science.gov (United States)

    Langfield, Richard D; Scarano, Frank J; Heitzman, Mary E; Kondo, Miwako; Hammond, Gerald B; Neto, Catherine C

    2004-10-01

    A versatile microplate bioassay for quick and sensitive determination of antibacterial activity was developed for use in screening medicinal plants and identification of their active principles. This assay can be used to determine minimum inhibitory concentrations for small quantities of organic or water-soluble plant extracts. Bioassay-guided fractionation of the stem and leaves of Peperomia galioides using this method found fractions containing grifolin and grifolic acid, which inhibited growth of Staphylococcus aureus and Staphylococcus epidermidis.

  12. Comparative susceptibility of bemisia tabaci to imidacloprid in field- and laboratory-based bioassays

    Science.gov (United States)

    Bemisia tabaci biotype B is a resistance-prone pest of protected and open agriculture. Systemic uptake bioassays used in resistance monitoring programs have provided important information on susceptibility to neonicotinoid insecticides, but have remained decoupled from field performance. Simultaneou...

  13. Evaluation of two autoinducer-2 quantification methods for application in marine environments

    KAUST Repository

    Wang, Tian-Nyu; Kaksonen, Anna H.; Hong, Pei-Ying

    2018-01-01

    This study evaluated two methods, namely high performance liquid chromatography with fluorescence detection (HPLC-FLD) and Vibrio harveyi BB170 bioassay, for autoinducer-2 (AI-2) quantification in marine samples. Using both methods, the study also

  14. In situ bioassays with Chironomus riparius larvae to biomonitor metal pollution in rivers and to evaluate the efficiency of restoration measures in mine areas

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Mafalda S. [CESAM and Departamento de Biologia da Universidade de Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal)], E-mail: mafaldafaria@sapo.pt; Lopes, Ricardo J. [CIBIO, Centro de Investigacao em Biodiversidade e Recursos Geneticos, Campus Agrario de Vairao, 4485-661 Vairao (Portugal); Malcato, Joao; Nogueira, Antonio J.A.; Soares, Amadeu M.V.M. [CESAM and Departamento de Biologia da Universidade de Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal)

    2008-01-15

    In this study we evaluate the ability of an in situ bioassay with Chironomus riparius larvae, using larval development and growth as endpoints, to biomonitor water quality and to assess the biological recovery of metal contaminated freshwater ecosystems of mine areas that are subject of restoration measures. The bioassay was carried out in streams located near an abandoned goldmine in North Portugal, throughout an environmental rehabilitation of the mine (2002-2004). During this period, a decrease in the inhibition of larval growth in the metal contaminated stream was observed. The bioassay was also performed in streams located near an active tungsten mine in Central Portugal. Larval growth and development were highly inhibited in the stream that receives acid drainage from the tungsten mine and treated water from the AMD treatment station. The results indicate that the bioassay can be used to evaluate the efficiency of environmental restoration measures in mining areas. - In situ bioassays with Chironomus riparius larvae can be a suitable tool to monitor restoration efficiency after a long time of metallic sediment contamination.

  15. In situ bioassays with Chironomus riparius larvae to biomonitor metal pollution in rivers and to evaluate the efficiency of restoration measures in mine areas

    International Nuclear Information System (INIS)

    Faria, Mafalda S.; Lopes, Ricardo J.; Malcato, Joao; Nogueira, Antonio J.A.; Soares, Amadeu M.V.M.

    2008-01-01

    In this study we evaluate the ability of an in situ bioassay with Chironomus riparius larvae, using larval development and growth as endpoints, to biomonitor water quality and to assess the biological recovery of metal contaminated freshwater ecosystems of mine areas that are subject of restoration measures. The bioassay was carried out in streams located near an abandoned goldmine in North Portugal, throughout an environmental rehabilitation of the mine (2002-2004). During this period, a decrease in the inhibition of larval growth in the metal contaminated stream was observed. The bioassay was also performed in streams located near an active tungsten mine in Central Portugal. Larval growth and development were highly inhibited in the stream that receives acid drainage from the tungsten mine and treated water from the AMD treatment station. The results indicate that the bioassay can be used to evaluate the efficiency of environmental restoration measures in mining areas. - In situ bioassays with Chironomus riparius larvae can be a suitable tool to monitor restoration efficiency after a long time of metallic sediment contamination

  16. Strategies for Transferring Mixtures of Organic Contaminants from Aquatic Environments into Bioassays

    DEFF Research Database (Denmark)

    Jahnke, Annika; Mayer, Philipp; Schäfer, Sabine

    2016-01-01

    and monitoring of such mixtures, a variety of cell-based in vitro and low-complexity in vivo bioassays based on algae, daphnids or fish embryos are available. A very important and sometimes unrecognized challenge is how to combine sampling, extraction and dosing to transfer the mixtures from the environment...

  17. Development of a chick bioassay for determination of infectivity of viral pathogens in poultry litter.

    Science.gov (United States)

    Islam, A F M F; Walkden-Brown, S W; Groves, P J; Wells, B

    2013-01-01

    To develop a chicken bioassay to detect infective viral pathogens in poultry litter and to determine the effects of type of chicken and age of exposure, as well as the effect of simulated litter transportation, on the level of viral infectivity detected. A 5 × 2 × 2 factorial design, plus negative controls. Five chicken litters, including two with deliberate contamination (one transported and one not), two chicken types (specific-pathogen-free (SPF) Leghorns and Cobb broilers) and two ages at initial exposure (days 1 and 8). Two replicates of each treatment combination. The 10 chickens in each of 22 isolators were either exposed (20 isolators) or not (2 isolators) to 8 L of previously used or deliberately contaminated poultry litter in two deep scratch trays. At day 35 post-exposure, sera were assayed for antibodies against chicken anaemia virus (CAV), infectious bronchitis virus (IBV), infectious bursal disease virus (IBDV), Newcastle disease virus (NDV) and fowl adenovirus (FAV). Spleen samples were tested for Marek's disease virus (MDV) using real-time polymerase chain reaction. The bioassay detected CAV, IBDV and FAV, but not NDV, IBV or MDV, in chickens exposed to infected litters. Infection in SPF chickens was detected with greater sensitivity than in the broiler chickens. Sensitivity increased with age at exposure in broiler but not SPF chickens. Simulated transportation for 24 h had little effect on pathogen detection. A bioassay based on the exposure of day-old SPF chickens to poultry litter and measurement of seroconversion at day 35 post-exposure is a useful semi-quantitative assay for viral infectivity in poultry litter, with overnight transportation of litter having little effect on the level of viral infectivity detected. This bioassay has applications in research on litter treatment protocols. © 2013 The Authors. Australian Veterinary Journal © 2013 Australian Veterinary Association.

  18. Fluorescence lifetime based bioassays

    Science.gov (United States)

    Meyer-Almes, Franz-Josef

    2017-12-01

    Fluorescence lifetime (FLT) is a robust intrinsic property and material constant of fluorescent matter. Measuring this important physical indicator has evolved from a laboratory curiosity to a powerful and established technique for a variety of applications in drug discovery, medical diagnostics and basic biological research. This distinct trend was mainly driven by improved and meanwhile affordable laser and detection instrumentation on the one hand, and the development of suitable FLT probes and biological assays on the other. In this process two essential working approaches emerged. The first one is primarily focused on high throughput applications employing biochemical in vitro assays with no requirement for high spatial resolution. The second even more dynamic trend is the significant expansion of assay methods combining highly time and spatially resolved fluorescence data by fluorescence lifetime imaging. The latter approach is currently pursued to enable not only the investigation of immortal tumor cell lines, but also specific tissues or even organs in living animals. This review tries to give an actual overview about the current status of FLT based bioassays and the wide range of application opportunities in biomedical and life science areas. In addition, future trends of FLT technologies will be discussed.

  19. Ecotoxicological assessment of metal-polluted urban soils using bioassays with three soil invertebrates.

    NARCIS (Netherlands)

    Santarufo, L.; van Gestel, C.A.M.; Maisto, G.

    2012-01-01

    This study aimed at assessing the quality of urban soils by integrating chemical and ecotoxicological approaches. Soils from five sites in downtown Naples, Italy, were sampled and characterized for physical-chemical properties and total and water-extractable metal concentrations. Bioassays with

  20. Proof of concept for a novel insecticide bioassay based on sugar feeding by adult Aedes aegypti (Stegomyia aegypti).

    Science.gov (United States)

    Stell, F M; Roe, R M; Arellano, C; Kennedy, L; Thornton, H; Saavedra-Rodriguez, K; Wesson, D M; Black, W C; Apperson, C S

    2013-09-01

    Aedes aegypti L. (Stegomyia aegypti) (Diptera: Culicidae) is the principal vector of dengue and yellow fever viruses in tropical and subtropical regions of the world. Disease management is largely based on mosquito control achieved by insecticides applied to interior resting surfaces and through space sprays. Population monitoring to detect insecticide resistance is a significant component of integrated disease management programmes. We developed a bioassay method for assessing insecticide susceptibility based on the feeding activity of mosquitoes on plant sugars. Our prototype sugar-insecticide feeding bioassay system was composed of inexpensive, disposable components, contained minimal volumes of insecticide, and was compact and highly transportable. Individual mosquitoes were assayed in a plastic cup that contained a sucrose-permethrin solution. Trypan blue dye was added to create a visual marker in the mosquito's abdomen for ingested sucrose-permethrin solution. Blue faecal spots provided further evidence of solution ingestion. With the sugar-insecticide feeding bioassay, the permethrin susceptibility of Ae. aegypti females from two field-collected strains was characterized by probit analysis of dosage-response data. The field strains were also tested by forced contact of females with permethrin residues on filter paper. Dosage-response patterns were similar, indicating that the sugar-insecticide feeding bioassay had appropriately characterized the permethrin susceptibility of the two strains. © 2012 The Royal Entomological Society.

  1. Determination of 5-fluorouracil in plasma with HPLC-tandem mass spectrometry

    NARCIS (Netherlands)

    van Kuilenburg, A. B. P.; van Lenthe, H.; Maring, J. G.; van Gennip, A. H.

    2006-01-01

    In this article, we describe a fast and specific method to measure 5FU with HPLC tandem-mass spectrometry. Reversed-phase HPLC was combined with electrospray ionization tandem mass spectrometry and detection was performed by multiple-reaction monitoring. Stable-isotope-labeled 5FU (1,3-15N2-5FU) was

  2. A Choline Oxidase Amperometric Bioassay for the Detection of Mustard Agents Based on Screen-Printed Electrodes Modified with Prussian Blue Nanoparticles

    Directory of Open Access Journals (Sweden)

    Fabiana Arduini

    2015-02-01

    Full Text Available In this work a novel bioassay for mustard agent detection was proposed. The bioassay is based on the capability of these compounds to inhibit the enzyme choline oxidase. The enzymatic activity, which is correlated to the mustard agents, was electrochemically monitored measuring the enzymatic product, hydrogen peroxide, by means of a screen-printed electrode modified with Prussian Blue nanoparticles. Prussian Blue nanoparticles are able to electrocatalyse the hydrogen peroxide concentration reduction at low applied potential (−50 mV vs. Ag/AgCl, thus allowing the detection of the mustard agents with no electrochemical interferences. The suitability of this novel bioassay was tested with the nitrogen mustard simulant bis(2-chloroethylamine and the sulfur mustard simulants 2-chloroethyl ethyl sulfide and 2-chloroethyl phenyl sulfide. The bioassay proposed in this work allowed the detection of mustard agent simulants with good sensitivity and fast response, which are excellent premises for the development of a miniaturised sensor well suited for an alarm system in case of terrorist attacks.

  3. High-throughput tri-colour flow cytometry technique to assess Plasmodium falciparum parasitaemia in bioassays

    DEFF Research Database (Denmark)

    Tiendrebeogo, Regis W; Adu, Bright; Singh, Susheel K

    2014-01-01

    BACKGROUND: Unbiased flow cytometry-based methods have become the technique of choice in many laboratories for high-throughput, accurate assessments of malaria parasites in bioassays. A method to quantify live parasites based on mitotracker red CMXRos was recently described but consistent...... distinction of early ring stages of Plasmodium falciparum from uninfected red blood cells (uRBC) remains a challenge. METHODS: Here, a high-throughput, three-parameter (tri-colour) flow cytometry technique based on mitotracker red dye, the nucleic acid dye coriphosphine O (CPO) and the leucocyte marker CD45...... for enumerating live parasites in bioassays was developed. The technique was applied to estimate the specific growth inhibition index (SGI) in the antibody-dependent cellular inhibition (ADCI) assay and compared to parasite quantification by microscopy and mitotracker red staining. The Bland-Altman analysis...

  4. Bioassay using the water soluble fraction of a Nigerian Light Crude ...

    African Journals Online (AJOL)

    Summary: A 96-hour bioassay was conducted using the water soluble fraction of a Nigerian light crude oil sample on Clarias gariepinus fingerlings. 0, 2.5, 5.0, 7.5 and 10 mls of water soluble fractions (WSF) of the oil were added to 1000 litres of de-chlorinated tap water to form 0, 25, 50 , 75 and 100 parts per million ...

  5. Multi-Analyte Separation Methods for HPLC Determination of the Active Ingredients of Pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Virtics, I.; Korsós, I.; Homoki, E.; Lantos, J. [Plant Protection and Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The practical quality control of selected pesticides, such as carbamates, organophosphorous compounds, phthalimides, pyrethroids, with HPLC is described. Detailed descriptions are given of materials and methods used, including sample preparation and HPLC operating conditions. The relationship between pH value of the HPLC eluent and the logP{sub ow} is discussed, illustrated by chromatograms, graphics and tables. The results are also compared with those elaborated by. E. Dudar and presented above. (author)

  6. Detection of estrogen receptor endocrine disruptor potency of commonly used organochlorine pesticides using the LUMI-CELL ER bioassay

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, J D; Chu, A C; Clark, G C [Xenobiotic Detection Systems, Inc., Durham, NC (United States); Chu, M D [Alta Analytical Perspectives, Wilmington, NC (United States); Denison, M S [Dept. of Environmental Toxicology, Univ. of California, Davis, CA (United States)

    2004-09-15

    In order to detect the endocrine disrupting potency of organochlorine pesticides and other compounds, BG-1 (human ovarian carcinoma) cells containing a stably transfected estrogenresponsive luciferase reporter gene plasmid (BG1Luc4E2), was used. This cell line, termed the LUMI-CELL trademark ER estrogenic cell bioassay system, responds in a time-, dose dependent- and chemical-specific manner with the induction of luciferase gene expression in response to exposure to estrogen (but not other steroid hormones) and estrogenic chemicals in a high-throughput screening (HTPS) format6. Here we describe studies in which the LUMI-CELL trademark ER estrogenic cell bioassay system was used for high throughput screening (HTPS) analysis of the estrogenic disrupting potency of several commonly used pesticides and organochlorines: p,p'DDT; p,p'-DDE; DDD; {alpha}a-chlordane; {psi}-chlordane; Kepone; Methoxychlor; Vinclozolin; Fenarimol; 2,4,5-Trichlorophenoxyacetic Acid; and Dieldrin. Our results demonstrate the utility of XDS's LUMI-CELL trademark ER bioassay HTPS system for screening chemicals for estrogenic activity.

  7. Field and Bioassay Indicators for Internal Dose Intervention Therapy

    International Nuclear Information System (INIS)

    Carbaugh, Eugene H.

    2007-01-01

    Guidance is presented that is used at the U.S. Department of Energy Hanford Site to identify the potential need for medical intervention in response to intakes of radioactivity. The guidance, based on ICRP Publication 30 models and committed effective dose equivalents of 20 mSv and 200 mSv, is expressed as numerical workplace measurements and derived first-day bioassay results for large intakes. It is used by facility radiation protection staff and on-call dosimetry support staff during the first few days following an intake

  8. Biomarkers and bioassays as alternative screening methods for the presence and effects of PCDD, PCDF and PCB

    International Nuclear Information System (INIS)

    Bosveld, A.T.C.B.; Berg, M.V.

    1994-01-01

    Polyhalogenated aromatic hydrocarbons (PHAH) are wide spread, highly toxic, environmental contaminants. As such they pose risks for both humans and wildlife. For risk assessment purposes, concentrations are generally analyzed by HRGC-HR/LRMS. With the analytical data, mixture toxicity is calculated using the TEF concept. With this method only the defined congeners are taken into account and additivity for all congeners is assumed, whereas synergistic and antagonistic effects for several PCDD/F in combination with PCB have also been reported. To avoid these problems and high analytical costs, bioassays can be used for screening purposes. Cytochrome P 450 1 A 1 induction and vitamin A and thyroid hormone levels are shown to be useful markers for PHAH exposure. When bioassays based on cytochrome P 450 1 A 1 induction, in cultured cells, in multi-well culturing plates, are used, 2,3,7,8-TCDD detection limits <0.2 pg are possible. As such these bioassays are highly sensitive, cost effective and time saving. This application can be used as a pre-screening method to determine total ''dioxin'' content of environmental samples. (orig.)

  9. Log bioassay of residual effectiveness of insecticides against bark beetles

    Science.gov (United States)

    Richard H. Smith

    1982-01-01

    Residual effectiveness of nine insecticides applied to bark was tested against western, mountain, and Jeffrey pine beetles. Ponderosa and Jeffrey pine trees were treated and logs cut from them 2 to 13 months later, and bioassayed with the three beetles. The insecticides were sprayed at the rate of 1 gal (3.8 l) per 40- or 80-ft² (3.6 or 7.2 m²) bark surface at varying...

  10. Radio-activity detectors in HPLC

    International Nuclear Information System (INIS)

    Kremers, H.D.

    1984-01-01

    Two different approaches were adopted to put the eluate from the HPLC into contact with the scintillator, i.e. a homogeneous and a heterogeneous system. In the heterogeneous system, the eluate runs directly through a cell filled with a fine-grain solid scintillator. In the homogeneous system, a liquid scintillator is admixed to the eluate or to a proportion of the eluate before flowing through the measurement cell. Both systems are contrasted with the fractionation method according to the criterias of handling, rapidity of analysis and facility cost. On-line detection of radio-activity will be easily settled for when comparing its investment cost with those of materials consumed in fractionation. A device prepared for scintillator admixture contains an integrated scintillator pump and a mixer but is suitable for application of solid scintillator cells, too. Such a system features a wider range of practical applications than a device exclusively designed for the heterogeneous system. A further asset of the detectors in the fact that they are adapted in their performance to up-to-date HPLC facilities in terms of speed and resolution. (orig./HP) [de

  11. Bioassays for Evaluating Water Quality: Screening for total bioactivity to assess water safety

    Science.gov (United States)

    Bioassays are a potential solution for assessing complex samples since they screen for total bioactivity for a given pathway or mode of action (MOA), such as estrogen receptor activation, in the samples. Overall, they can account for the three challenges listed above, and can sim...

  12. Comparison of piracetam measured with HPLC-DAD, HPLC-ESI-MS, DIP-APCI-MS, and a newly developed and optimized DIP-ESI-MS.

    Science.gov (United States)

    Lenzen, Claudia; Winterfeld, Gottfried A; Schmitz, Oliver J

    2016-06-01

    The direct inlet probe-electrospray ionization (DIP-ESI) presented here was based on the direct inlet probe-atmospheric pressure chemical ionization (DIP-APCI) developed by our group. It was coupled to an ion trap mass spectrometer (MS) for the detection of more polar compounds such as degradation products from pharmaceuticals. First, the position of the ESI tip, the gas and solvent flow rates, as well as the gas temperature were optimized with the help of the statistic program Minitab® 17 and a caffeine standard. The ability to perform quantitative analyses was also tested by using different concentrations of caffeine and camphor. Calibration curves with a quadratic calibration regression of R (2) = 0.9997 and 0.9998 for caffeine and camphor, respectively, were obtained. The limit of detection of 2.5 and 1.7 ng per injection for caffeine and camphor were determined, respectively. Furthermore, a solution of piracetam was used to compare established analytical methods for this drug and its impurities such as HPLC-diode array detector (DAD) and HPLC-ESI-MS with the DIP-APCI and the developed DIP-ESI. With HPLC-DAD and 10 μg piracetam on column, no impurity could be detected. With HPLC-ESI-MS, two impurities (A and B) were identified with only 4.6 μg piracetam on column, while with DIP-ESI, an amount of 1.6 μg piracetam was sufficient. In the case of the DIP-ESI measurements, all detected impurities could be identified by MS/MS studies. Graphical Abstract Scheme of the DIP-ESI principle.

  13. Rapid bioassay method for estimation of 90Sr in urine samples by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Chaudhary, Seema; Sawant, Pramilla D.

    2018-01-01

    Radiostrontium (Sr) is a by-product of the nuclear fission of uranium and plutonium in nuclear reactors and is an important radionuclide in spent nuclear fuel and radioactive waste. Rapid bioassay methods are required for estimating Sr in urine following internal contamination. Decision regarding medical intervention, if any can be based upon the results of urinalysis. The present method used at Bioassay Laboratory, Trombay is by Solid Extraction Chromatography (SEC) technique. The Sr separated from urine sample is precipitated as SrCO 3 and analyzed gravimetrically. However, gravimetric procedure is time consuming and therefore, in the present study, feasibility of Liquid Scintillation Counting for direct detection of radiostrontium in effluent was explored. The results obtained in the present study were compared with those obtained using gravimetric method

  14. Selection of gonadotrophin surge attenuating factor phage antibodies by bioassay.

    Science.gov (United States)

    Sorsa-Leslie, Tarja; Mason, Helen D; Harris, William J; Fowler, Paul A

    2005-09-26

    We aimed to combine the generation of "artificial" antibodies with a rat pituitary bioassay as a new strategy to overcome 20 years of difficulties in the purification of gonadotrophin surge-attenuating factor (GnSAF). A synthetic single-chain antibody (Tomlinson J) phage display library was bio-panned with partially purified GnSAF produced by cultured human granulosa/luteal cells. The initial screening with a simple binding immunoassay resulted in 8 clones that were further screened using our in-vitro rat monolayer bioassay for GnSAF. Initially the antibodies were screened as pooled phage forms and subsequently as individual, soluble, single-chain antibody (scAbs) forms. Then, in order to improve the stability of the scAbs for immunopurification purposes, and to widen the range of labelled secondary antibodies available, these were engineered into full-length human immunoglobulins. The immunoglobulin with the highest affinity for GnSAF and a previously described rat anti-GnSAF polyclonal antiserum was then used to immunopurify bioactive GnSAF protein. The two purified preparations were electrophoresed on 1-D gels and on 7 cm 2-D gels (pH 4-7). The candidate GnSAF protein bands and spots were then excised for peptide mass mapping. Three of the scAbs recognised GnSAF bioactivity and subsequently one clone of the purified scAb-derived immunoglobulin demonstrated high affinity for GnSAF bioactivity, also binding the molecule in such as way as to block its bioactivity. When used for repeated immunopurification cycles and then Western blot, this antibody enabled the isolation of a GnSAF-bioactive protein band at around 66 kDa. Similar results were achieved using the rat anti-GnSAF polyclonal antiserum. The main candidate molecules identified from the immunopurified material by excision of 2-D gel protein spots was human serum albumin precursor and variants. This study demonstrates that the combination of bioassay and phage display technologies is a powerful tool in the

  15. Bioassays for TSH Receptor Autoantibodies, from FRTL-5 Cells to TSH Receptor-LH/CG Receptor Chimeras: The Contribution of Leonard D. Kohn.

    Science.gov (United States)

    Giuliani, Cesidio; Saji, Motoyasu; Bucci, Ines; Napolitano, Giorgio

    2016-01-01

    Since the discovery 60 years ago of the "long-acting thyroid stimulator" by Adams and Purves, great progress has been made in the detection of thyroid-stimulating hormone (TSH) receptor (TSHR) autoantibodies (TRAbs) in Graves' disease. Today, commercial assays are available that can detect TRAbs with high accuracy and provide diagnostic and prognostic evaluation of patients with Graves' disease. The present review focuses on the development of TRAbs bioassays, and particularly on the role that Leonard D. Kohn had in this. Indeed, 30 years ago, the Kohn group developed a bioassay based on the use of FRTL-5 cells that was characterized by high reproducibility, feasibility, and diagnostic accuracy. Using this FRTL-5 bioassay, Kohn and his colleagues were the first to develop monoclonal antibodies (moAbs) against the TSHR. Furthermore, they demonstrated the multifaceted functional nature of TRAbs in patients with Graves' disease, with the identification of stimulating and blocking TRAbs, and even antibodies that activated pathways other than cAMP. After the cloning of the TSHR, the Kohn laboratory constructed human TSHR-rat luteinizing hormone/chorionic gonadotropin receptor chimeras. This paved the way to a new bioassay based on the use of non-thyroid cells transfected with the Mc4 chimera. The new Mc4 bioassay is characterized by high diagnostic and prognostic accuracy, greater than for other assays. The availability of a commercial kit based on the Mc4 chimera is spreading the use of this assay worldwide, indicating its benefits for these patients with Graves' disease. This review also describes the main contributions made by other researchers in TSHR molecular biology and TRAbs assay, especially with the development of highly potent moAbs. A comparison of the diagnostic accuracies of the main TRAbs assays, as both immunoassays and bioassays, is also provided.

  16. Multielemental speciation analysis by advanced hyphenated technique - HPLC/ICP-MS: A review.

    Science.gov (United States)

    Marcinkowska, Monika; Barałkiewicz, Danuta

    2016-12-01

    Speciation analysis has become an invaluable tool in human health risk assessment, environmental monitoring or food quality control. Another step is to develop reliable multielemental speciation methodologies, to reduce costs, waste and time needed for the analysis. Separation and detection of species of several elements in a single analytical run can be accomplished by high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC/ICP-MS). Our review assembles articles concerning multielemental speciation determination of: As, Se, Cr, Sb, I, Br, Pb, Hg, V, Mo, Te, Tl, Cd and W in environmental, biological, food and clinical samples analyzed with HPLC/ICP-MS. It addresses the procedures in terms of following issues: sample collection and pretreatment, selection of optimal conditions for elements species separation by HPLC and determination using ICP-MS as well as metrological approach. The presented work is the first review article concerning multielemental speciation analysis by advanced hyphenated technique HPLC/ICP-MS. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Cancer risk assessment of polycyclic aromatic hydrocarbon contaminated soils determined using bioassay-derived levels of benzo[a]pyrene equivalents.

    Science.gov (United States)

    Lemieux, Christine L; Long, Alexandra S; Lambert, Iain B; Lundstedt, Staffan; Tysklind, Mats; White, Paul A

    2015-02-03

    Here we evaluate the excess lifetime cancer risk (ELCR) posed by 10 PAH-contaminated soils using (i) the currently advocated, targeted chemical-specific approach that assumes dose additivity for carcinogenic PAHs and (ii) a bioassay-based approach that employs the in vitro mutagenic activity of the soil fractions to determine levels of benzo[a]pyrene equivalents and, by extension, ELCR. Mutagenic activity results are presented in our companion paper.1 The results show that ELCR values for the PAH-containing fractions, determined using the chemical-specific approach, are generally (i.e., 8 out of 10) greater than those calculated using the bioassay-based approach; most are less than 5-fold greater. Only two chemical-specific ELCR estimates are less than their corresponding bioassay-derived values; differences are less than 10%. The bioassay-based approach, which permits estimation of ELCR without a priori knowledge of mixture composition, proved to be a useful tool to evaluate the chemical-specific approach. The results suggest that ELCR estimates for complex PAH mixtures determined using a targeted, chemical-specific approach are reasonable, albeit conservative. Calculated risk estimates still depend on contentious PEFs and cancer slope factors. Follow-up in vivo mutagenicity assessments will be required to validate the results and their relevance for human health risk assessment of PAH-contaminated soils.

  18. Lanthanide-doped upconverting phosphors for bioassay and therapy

    Science.gov (United States)

    Guo, Huichen; Sun, Shiqi

    2012-10-01

    Lanthanide-doped fluorescent materials have gained increasing attention in recent years due to their unique luminescence properties which have led to their use in wide-ranging fields including those of biological applications. Aside from being used as agents for in vivo imaging, lanthanide-doped fluorescent materials also present many advantages for use in bioassays and therapy. In this review, we summarize the applications of lanthanide-doped up-converting phosphors (UCPs) in protein and gene detection, as well as in photodynamic and gene therapy in recent years, and outline their future potential in biological applications. The current report could serve as a reference for researchers in relevant fields.

  19. Bioassay for uranium mill tailings

    International Nuclear Information System (INIS)

    Tschaeche, A.N.

    1986-01-01

    Uranium mill tailings are composed of fine sand that contains, among other things, some uranium (U/sup 238/ primarily), and all of the uranium daughters starting with /sup 230/Th that are left behind after the usable uranium is removed in the milling process. Millions of pounds of tailings are and continue to be generated at uranium mills around the United States. Discrete uranium mill tailings piles exist near the mills. In addition, the tailings materials were used in communities situated near mill sites for such purposes as building materials, foundations for buildings, pipe runs, sand boxes, gardens, etc. The Uranium Mill Tailings Remedial Action Project (UMTRAP) is a U.S. Department of Energy Program designed with the intention of removing or stabilizing the mill tailings piles and the tailings used to communities so that individuals are not exposed above the EPA limits established for such tailings materials. This paper discusses the bioassay programs that are established for workers who remove tailings from the communities in which they are placed

  20. HPLC FOR CONTROL STABILITY OF QUERCETIN INJECTABLE DOSAGE FORM

    Directory of Open Access Journals (Sweden)

    Martynov AV

    2016-12-01

    Full Text Available Introduction. Quercetin is a flavone derivatives which known like a substances with vitamin activity, high antioxidant, antimutagenic and anticarcinogenic activity and many other types of biological activity. Wide usage of quercetin prevents their polyphenolic nature structure which does not allow a high bioavailability of pure quercetin when administered orally. This is associated with a wide spectrum variety of chemical reactions for the phenolic groups: from interaction with amino acid residues in proteins to reactions with amine heterocyclic alkaloids and polysaccharides. In our days Corvitin – one from the number of quercetin based drugs with sufficiently low levels all types toxicity, allergenic and has no irritating action on intravenous administration. In the same time quercetin cannot be used in full measure because of the limited number of publications with analysis methods, especially HPLC. Determining the stability over time of concentrate quercetin solution, as well as determining the stability of the concentrate to the original autoclave sterilization conditions is a promising direction in creating new drugs. Materials and methods The objective was to research quercetin soluble formulation samples in different conditions: 1 fresh dilute concentrate (0.9% sodium chloride; 2 the original dilute concentrate, which was stored at room temperature for 14 days in light and 3 similar to the first sample dilute concentrate, which went before breeding in autoclaving at 120 0 C for 20 minutes. The objects used in the studies were industrial drug-substance quercetin (Sinkea manufactured (China, the original pharmaceutical composition as the soluble form of quercetin for injection and aerosol applications, glycerol (Sigma, Polysorbat 80 (Merk, ethanol 96 %. For the HPLC – analysis, chromatograph "Milichrom A-02" (SiChrom, Knauer (Econova, Novosibirsk, Russia was used. Results and discussion Quercetin was identified using information on its

  1. An aggregated perylene-based broad-spectrum, efficient and label-free quencher for multiplexed fluorescent bioassays.

    Science.gov (United States)

    Liu, Tao; Hu, Rong; Lv, Yi-Fan; Wu, Yuan; Liang, Hao; Huan, Shuang-Yan; Zhang, Xiao-Bing; Tan, Weihong; Yu, Ru-Qin

    2014-08-15

    Fluorescent sensing systems based on the quenching of fluorophores have found wide applications in bioassays. An efficient quencher will endow the sensing system a high sensitivity. The frequently used quenchers are based on organic molecules or nanomaterials, which usually need tedious synthesizing and modifying steps, and exhibit different quenching efficiencies to different fluorophores. In this work, we for the first time report that aggregated perylene derivative can serve as a broad-spectrum and label-free quencher that is able to efficiently quench a variety of fluorophores, such as green, red and far red dyes labeled on DNA. By choosing nucleases as model biomolecules, such a broad-spectrum quencher was then employed to construct a multiplexed bioassay platform through a label-free manner. Due to the high quenching efficiency of the aggregated perylene, the proposed platform could detect nuclease with high sensitivity, with a detection limit of 0.03U/mL for EcoRV, and 0.05U/mL for EcoRI. The perylene quencher does not affect the activity of nuclease, which makes it possible to design post-addition type bioassay platform. Moreover, the proposed platform allows simultaneous and multicolor analysis of nucleases in homogeneous solution, demonstrating its value of potential application in rapid screening of multiple bio-targets. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Measurements of urinary kinins by HPLC-radioimmunoassay

    International Nuclear Information System (INIS)

    Fejes-Toth, G.; Naray-Fejes-Toth, A.; Froelich, J.C.

    1984-01-01

    In this paper the authors describe a method for the individual determination of urinary kinins. Extraction from the urine is performed on an Amberlite CG-50 column and kinins are eluted with formic acid. The samples are further purified and kinins are separated by reversed phase HPLC. Bradykinin and lysylbradykinin are quantified by a sensitive radioimmunoassay capable of detecting 0.1 fmol of either peptide. Procedural losses are monitored by measuring the recovery of [ 3 H]bradykinin and [ 3 H]lysylbradykinin. Simple methods for labeling of bradykinin and lysylbradykinin with tritium are also presented. Recoveries of [ 3 H]bradykinin and [ 3 H]lysylbradykinin from biological material ranged between 77 and 91%. The combination of HPLC with radioimmunoassay makes it possible to determine kinin concentrations of biological samples with a higher sensitivity and greater specificity than previous methods. (Auth.)

  3. Recent developments in HPLC analysis of β-blockers in biological samples.

    Science.gov (United States)

    Saleem, Kishwar; Ali, Imran; Kulsum, Umma; Aboul-Enein, Hassan Y

    2013-09-01

    β-Adrenergic blockers represent a very important class of drugs that are used worldwide for treating various cardiac diseases. The present article describes the state-of-the art of analyses of β-adrenergic blockers using high-performance liquid chromatography (HPLC). Sample preparation techniques such as liquid-liquid extraction, solid-phase extraction and solid-phase microextraction have been discussed, which are essential prior to HPLC analysis. Additionally, applications of liquid chromatography coupled with tandem mass spectrometry are included. HPLC methods have been reported to include 0.6-26 min as the run times and 0.01 ng/mL to 25 µg/mL as detection limits. The most commonly used columns were C18 with various buffers as the mobile phases, along with various organic modifiers. The optimization of HPLC conditions has been discussed. It has been observed that the reported methods are quite satisfactory for the analyses of β-adrenergic blockers in biological samples. Future perspectives in the hyphenation of solid-phase microextraction-nano-liquid chromatography-tandem mass spectrometry have also been highlighted to achieve detections at nanogram and picogram levels. The present article is very useful for academicians, scientists, drug and pharmaceutical personnel and government regulatory authorities.

  4. Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program

    International Nuclear Information System (INIS)

    Antonio, Cheryl L.; Rivard, James W.

    2009-01-01

    During the decommissioning and maintenance of some of the facilities at the U.S. Department of Energy Hanford Site in Washington State, workers have potential for a 90Sr intake. However, because of worldwide radioactive fallout, 90Sr is present in our environment, and can be detectable in routine urine bioassay samples. It is important for the Hanford Site bioassay program to discern an occupational intake from a non-occupational environmental one. A detailed study of the background 90Sr in the urine of unexposed Hanford workers was performed. A survey of the Hanford Site bioassay database found 128 Hanford workers who were hired between 1997 and 2002 and who had a very low potential for an occupational exposure prior to the baseline strontium urinalysis. Each urinalysis sample represented excretion during an approximate 24-hr period. The arithmetic mean value for the 128 pre-exposure baselines was 3.6 ± 5.1 mBq d-1. The 90Sr activities in urine varied from -12 to 20 mBq. The 99th percentile result was 16.4 mBqd-1, which was interpreted to mean that 1% of Hanford workers not occupationally exposed to strontium might exceed 16.4 mBq d-1.

  5. Contaminated sediments and bioassay responses of three macroinvertebrates, the midge larva Chironomus riparius, the water louse Asellus aquaticus and the mayfly nymph Ephoron virgo

    NARCIS (Netherlands)

    Lange, de H.J.; Haas, de E.M.; Maas, H.; Peeters, E.T.H.M.

    2005-01-01

    Bioassays are widely used to estimate ecological risks of contaminated sediments. We compared the results of three whole sediment bioassays, using the midge larva Chironomus riparius, the water louse Asellus aquaticus, and the mayfly nymph Ephoron virgo. We used sediments from sixteen locations in

  6. Detection of estrogen receptor endocrine disruptor potency of commonly used organochlorine pesticides using the LUMI-CELL ER bioassay

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, J.D.; Chu, A.C.; Clark, G.C. [Xenobiotic Detection Systems, Inc., Durham, NC (United States); Chu, M.D. [Alta Analytical Perspectives, Wilmington, NC (United States); Denison, M.S. [Dept. of Environmental Toxicology, Univ. of California, Davis, CA (United States)

    2004-09-15

    In order to detect the endocrine disrupting potency of organochlorine pesticides and other compounds, BG-1 (human ovarian carcinoma) cells containing a stably transfected estrogenresponsive luciferase reporter gene plasmid (BG1Luc4E2), was used. This cell line, termed the LUMI-CELL trademark ER estrogenic cell bioassay system, responds in a time-, dose dependent- and chemical-specific manner with the induction of luciferase gene expression in response to exposure to estrogen (but not other steroid hormones) and estrogenic chemicals in a high-throughput screening (HTPS) format6. Here we describe studies in which the LUMI-CELL trademark ER estrogenic cell bioassay system was used for high throughput screening (HTPS) analysis of the estrogenic disrupting potency of several commonly used pesticides and organochlorines: p,p'DDT; p,p'-DDE; DDD; {alpha}a-chlordane; {psi}-chlordane; Kepone; Methoxychlor; Vinclozolin; Fenarimol; 2,4,5-Trichlorophenoxyacetic Acid; and Dieldrin. Our results demonstrate the utility of XDS's LUMI-CELL trademark ER bioassay HTPS system for screening chemicals for estrogenic activity.

  7. Genotoxic evaluation of an industrial effluent from an oil refinery using plant and animal bioassays.

    Science.gov (United States)

    Rodrigues, Fernando Postalli; Angeli, José Pedro Friedmann; Mantovani, Mário Sérgio; Guedes, Carmen Luisa Barbosa; Jordão, Berenice Quinzani

    2010-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are genotoxic chemicals commonly found in effluents from oil refineries. Bioassays using plants and cells cultures can be employed for assessing environmental safety and potential genotoxicity. In this study, the genotoxic potential of an oil refinery effluent was analyzed by means of micronucleus (MN) testing of Alium cepa, which revealed no effect after 24 h of treatment. On the other hand, primary lesions in the DNA of rat (Rattus norvegicus) hepatoma cells (HTC) were observed through comet assaying after only 2 h of exposure. On considering the capacity to detect DNA damage of a different nature and of these cells to metabolize xenobiotics, we suggest the association of the two bioassays with these cell types, plant (Allium cepa) and mammal (HTC) cells, for more accurately assessing genotoxicity in environmental samples.

  8. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    Science.gov (United States)

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  9. APPLICATION OF PLANT AND EARTHWORM BIOASSAYS TO EVALUATE REMEDIATION OF A LEAD-CONTAMINATED SOIL

    Science.gov (United States)

    Earthworm acute toxicity, plant seed germination/root elongation (SG/RE) and plant genotoxicity bioassays were employed to evaluate the remediation of a lead-contaminated soil. The remediation involved removal of heavy metals by a soil washing/soil leaching treatment process. A p...

  10. Wastewater screening method for evaluating applicability of zero-valent iron to industrial wastewater

    International Nuclear Information System (INIS)

    Lee, J.W.; Cha, D.K.; Oh, Y.K.; Ko, K.B.; Jin, S.H.

    2010-01-01

    This study presents a screening protocol to evaluate the applicability of the ZVI pretreatment to various industrial wastewaters of which major constituents are not identified. The screening protocol consisted of a sequential analysis of UV-vis spectrophotometry, high-performance liquid chromatograph (HPLC), and bioassay. The UV-vis and HPLC analyses represented the potential reductive transformation of unknown constituents in wastewater by the ZVI. The UV-vis and HPLC results were quantified using principal component analysis (PCA) and Euclidian distance (ED). The short-term bioassay was used to assess the increased biodegradability of wastewater constituents after ZVI treatment. The screening protocol was applied to seven different types of real industrial wastewaters. After identifying one wastewater as the best candidate for the ZVI treatment, the benefit of ZVI pretreatment was verified through continuous operation of an integrated iron-sequencing batch reactor (SBR) resulting in the increased organic removal efficiency compared to the control. The iron pretreatment was suggested as an economical option to modify some costly physico-chemical processes in the existing wastewater treatment facility. The screening protocol could be used as a robust strategy to estimate the applicability of ZVI pretreatment to a certain wastewater with unknown composition.

  11. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    International Nuclear Information System (INIS)

    Karasawa, Koji; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-01-01

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H_2O_2 and O_2"− generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  12. A fish-feeding laboratory bioassay to assess the antipredatory activity of secondary metabolites from the tissues of marine organisms.

    Science.gov (United States)

    Marty, Micah J; Pawlik, Joseph R

    2015-01-11

    Marine chemical ecology is a young discipline, having emerged from the collaboration of natural products chemists and marine ecologists in the 1980s with the goal of examining the ecological functions of secondary metabolites from the tissues of marine organisms. The result has been a progression of protocols that have increasingly refined the ecological relevance of the experimental approach. Here we present the most up-to-date version of a fish-feeding laboratory bioassay that enables investigators to assess the antipredatory activity of secondary metabolites from the tissues of marine organisms. Organic metabolites of all polarities are exhaustively extracted from the tissue of the target organism and reconstituted at natural concentrations in a nutritionally appropriate food matrix. Experimental food pellets are presented to a generalist predator in laboratory feeding assays to assess the antipredatory activity of the extract. The procedure described herein uses the bluehead, Thalassoma bifasciatum, to test the palatability of Caribbean marine invertebrates; however, the design may be readily adapted to other systems. Results obtained using this laboratory assay are an important prelude to field experiments that rely on the feeding responses of a full complement of potential predators. Additionally, this bioassay can be used to direct the isolation of feeding-deterrent metabolites through bioassay-guided fractionation. This feeding bioassay has advanced our understanding of the factors that control the distribution and abundance of marine invertebrates on Caribbean coral reefs and may inform investigations in diverse fields of inquiry, including pharmacology, biotechnology, and evolutionary ecology.

  13. Comparison of ICRP Publication 30 lung model-based predictions with measured bioassay data for airborne natural UO2 exposure

    International Nuclear Information System (INIS)

    Thind, K.S.

    1987-01-01

    In this paper a comparison is made between the build-up of U thorax burdens and the predicted total lung (lung and lymph) burden, based on the lung model provided in ICRP Publication 30 for a group of 29 atomic radiation workers at a Canadian fuel fabrication facility. A similar comparison is made between the predicted ratio of the total lung burden to urinary excretion and the ratio obtained from bioassay data. The study period for the comparison is 5 y. The inhalation input for the lung model calculations was derived from air-sampling data and the choice of particle size activity median aerodynamic diameter (AMAD) was guided by particle size measurements made at representative work locations. The pulmonary clearance half-times studied were 100, 250 and 500 d. For the purpose of this comparison, averaged exposure and averaged bioassay data for the group were used. This comparison indicates that for the conditions of this facility, the assumption of a 500-d pulmonary clearance half-time and a particle size of 1 micron (AMAD) may be too conservative. It is suggested that measurements of air concentrations and particle size used as input parameters for the ICRP Publication 30 lung model may be used to calculate bioassay parameters which may then be tested against bioassay data obtained as part of an operational health physics program, thereby giving a useful step towards defining a derived air concentration value for U in the workplace

  14. Isolation and identification of phytochemicals and biological activities of Hericium ernaceus and their contents in Hericium strains using HPLC/UV analysis.

    Science.gov (United States)

    Lee, Dong Gu; Kang, Hee-Wan; Park, Chun-Geon; Ahn, Young-Sup; Shin, Yusu

    2016-05-26

    Hericium ernaceus has been traditionally used for the treatment of dyspepsia, gastric ulcer and enervation in traditional Chinese medicine for a long time. To examine the effect of Hericium strains on their ability to inhibit LPS and interferon-γ induced NO production in cell culture and the bioassay correlation of hericenone C, D, F, isolated from H. ernaceus. Hericenone C, D, F were isolated from H. ernaceus by open column chromatography and identified on the basis of spectroscopic analyses including (1)H NMR, (13)C NMR and MS. The amounts of hericenone C, D, and F in Hericium strains were determined by HPLC/UV analysis. In order to investigate the anti-inflammatory effect of Hericium strains extracts, RAW 264.7 cells were treated with 200μg/mL of Hericium strains extracts for 48h. Cell growth was assessed by MTT assay. Phytochemical constituents were isolated from H. ernaceus by open column chromatography. Their structures were elucidated as hericenones C, D, and F on the basis of spectroscopic analyses including (1)H NMR, (13)C NMR and MS. The amounts of hericenones C, D, and F in Hericium strains were determined by HPLC/UV analysis. Hericenones C, D, and F contents were highest in Norugungdenglee-2 (8.289±0.593mg/g), KFRI-1453 (4.657±0.462mg/g), and KFRI-1093 (5.408±0.420mg/g) strains, respectively. All Hericium strains extracts tested inhibited the lipopolysaccharide- and interferon-γ-induced inflammatory activity of RAW264.7 cells. The strain KFRI-1093 about 39.6% reduced NO generation with compared to control. We believe that the anti-inflammatory effect of KFRI-1093 was due to hericenone F content. Our results contribute towards validation of the traditional use, natural drugs and health supplements. And also, the developed simple, accurate and rapid LC method can be used determinate the content of hericenones from other Hericium strains. Copyright © 2016. Published by Elsevier Ireland Ltd.

  15. Bioassay techniques for 55Fe in urine samples

    International Nuclear Information System (INIS)

    Cregan, S.P.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for 55 Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH) 3 . precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs

  16. High performance liquid chromatography (HPLC fingerprints and primary structure identification of corn peptides by HPLC-diode array detection and HPLC-electrospray ionization tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chi Wang

    2016-01-01

    Full Text Available Corn peptides (CPs are reported to have many biological functions, such as facilitating alcohol metabolism, antioxidation, antitumor, antihypertension, and hepatoprotection. To develop a method for quality control, the high-performance liquid chromatography (HPLC system was applied. Twenty-eight common peaks were found in all the CPs of corn samples from Enshi, China, based on which, a fingerprinting chromatogram was established for use in quality control in future research. Subsequently, the major chemical constituents of these common peaks were identified respectively using the HPLC-diode-array detection electrospray ionization tandem mass spectrometry (DAD-ESI-MS/MS system, and 48 peptide fractions were determined ultimately. This was the first time for the majority of these peptides to be reported, and many of them contained amino acids of glutamine (Q, L and A, which might play an important role in the exhibition of the bioactivities of CPs. Many peptides had a similar primary structure to the peptides which had been proven to be bioactive such as facilitating alcohol metabolism, scavenging free radicals, and inhibiting lipid peroxidation. This systematical analysis of the primary structure of CPs facilitated subsequent studies on the relationship between the structures and functions, and could accelerate holistic research on CPs.

  17. A hybrid FIA/HPLC system incorporating monolithic column chromatography

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Francis, Paul S.; Agg, Kent M.; Marshall, Graham D.; Barnett, Neil W.

    2007-01-01

    We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2'-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection

  18. Establishing principal soil quality parameters influencing earthworms in urban soils using bioassays

    International Nuclear Information System (INIS)

    Hankard, Peter K.; Bundy, Jacob G.; Spurgeon, David J.; Weeks, Jason M.; Wright, Julian; Weinberg, Claire; Svendsen, Claus

    2005-01-01

    Potential contamination at ex-industrial sites means that, prior to change of use, it will be necessary to quantify the extent of risks to potential receptors. To assess ecological hazards, it is often suggested to use biological assessment to augment chemical analyses. Here we investigate the potential of a commonly recommended bioassay, the earthworm reproduction test, to assess the status of urban contaminated soils. Sample points at all study sites had contaminant concentrations above the Dutch soil criteria Target Values. In some cases, the relevant Intervention Values were exceeded. Earthworm survival at most points was high, but reproduction differed significantly in soil from separate patches on the same site. When the interrelationships between soil parameters and reproduction were studied, it was not possible to create a good model of site soil toxicity based on single or even multiple chemical measurements of the soils. We thus conclude that chemical analysis alone is not sufficient to characterize soil quality and confirms the value of biological assays for risk assessment of potentially contaminated soils. - Bioassays must be applied for the risk assessment complexly-polluted sites to complement chemical analysis of soils

  19. Use of a germination bioassay to test compost maturity in Tekelan Village

    Science.gov (United States)

    Oktiawan, Wiharyanto; Zaman, Badrus; Purwono

    2018-02-01

    Livestock waste from cattle farms in Tekelan village, Getasan Subdistrict, Semarang Regency can be grouped into three types, namely solid waste, slurry and waste water. Solid waste (cow dung) was processed into compost, while slurry and waste water were used to make liquid fertilizer. This compost was used as a component of planting media in horticultural crops and potted plants production. We evaluated the toxicity (phytochemical and ecotoxicological) test of compost by using germination index (GI). Vigna radiata seeds are sown on filter paper dampened with compost extract for different times. GI was calculated by relative germination (G) and relative radical length (L). The germination index (GI) = G / G0 x L / L0 x 100, where G0 and L0 are values obtained by distilled water as a control. The results showed that germination bioassay and radical length using aquades and groundwater in Tekelan village did not affect the radical length of Vigna radiata . Technically, groundwater in Tekelan village can be used as a germination bioassay control. The cow dung compost substrate appears to have a major influence on compost toxicity. Mature compost was produced on day 14 with a GI of 104.03.

  20. Evaluating the performance of the ORTECR DetectiveTM for emergency urine bioassay

    International Nuclear Information System (INIS)

    Li, C.; Ko, R.; Moodie, G.; Kramer, G. H.

    2011-01-01

    The performance of the ORTEC R Detective TM as a field deployable tool for emergency urine bioassay of 137 Cs, 60 Co, 192 Ir, 169 Yb and 75 Se was evaluated against ANSI N13.30. The tested activity levels represent 10 % RL (reference level) and 1 % RL defined by [Li C., Vlahovich S., Dai X., Richardson R. B., Daka J. N. and Kramer G. H. Requirements for radiation emergency urine bioassay techniques for the public and first responders. Health Phys (in press, 99(5), 702-707 (2010)]. The tests were conducted for both single radionuclide and mixed radionuclides at two geometries, one conventional geometry (CG) and one improved geometry (IG) which improved the MDAs (minimum detectable amounts) by a factor of 1.6-2.7. The most challenging radionuclide was 169 Yb. The measurement of the mixture radionuclides for 169 Yb at the CG did not satisfy the ANSI N13.30 requirements even at 10 % RL. At 1 % RL, 169 Yb and 192 Ir were not detectable at either geometry, while the measurement of 60 Co in the mixed radionuclides satisfied the ANSI N13.30 requirements only at the IG. (authors)

  1. Redox-flexible NADH oxidase biosensor: A platform for various dehydrogenase bioassays and biosensors

    International Nuclear Information System (INIS)

    Serban, Simona; El Murr, Nabil

    2006-01-01

    A generic amperometric bioassay based on the enzymatic oxidation catalysed by the stable NADH oxidase (NAox) from Thermus thermophilus has been developed for NADH measurements. The NAox uses O 2 as its natural electron acceptor and produces H 2 O 2 in a two-electron process. Electrochemical and spectrophotometric experiments showed that the NAox used in this work, presents a very good activity towards its substrate and, in contrary to previously mentioned NADH oxidases, does not require the addition of any exogenous flavin cofactor neither to promote nor to maintain its activity. In addition, the NAox used also works with artificial electron acceptors like ferrocene derivatives. O 2 was successfully replaced by redox mediators such as hydroxymethyl ferrocene (FcCH 2 OH) for the regeneration of the active enzyme. Combining the NAox with the mediator and the horseradish peroxidase we developed an original, high sensitive 'redox-flexible' NADH amperometric bioassay working in a large window of applied potentials in both oxidation and reduction modes. The biosensor has a continuous and complementary linearity range permitting to measure NADH concentrations starting from 5 x 10 -6 M in reduction until 2 x 10 3 M in oxidation. This redox-flexibility allows choosing the applied potential in order to avoid electrochemical interferences. The association of the 'redox-flexible' concept with NADH dependent enzymes opens a novel strategy for dehydrogenases based bioassays and biosensors. The great number of dehydrogenases available makes the concept applicable for numerous substrates to analyse. Moreover it allows the development of a wide range of biosensors on the basis of a generic platform. This gives several advantages over the previous manufacturing techniques and offers a general and flexible scheme for the fabrication of biosensors presenting high sensitivities, wide calibration ranges and less affected by electrochemical interferences

  2. Genotoxic evaluation of an industrial effluent from an oil refinery using plant and animal bioassays

    Directory of Open Access Journals (Sweden)

    Fernando Postalli Rodrigues

    2010-01-01

    Full Text Available Polycyclic aromatic hydrocarbons (PAHs are genotoxic chemicals commonly found in effluents from oil refineries. Bioassays using plants and cells cultures can be employed for assessing environmental safety and potential genotoxicity. In this study, the genotoxic potential of an oil refinery effluent was analyzed by means of micronucleus (MN testing of Alium cepa, which revealed no effect after 24 h of treatment. On the other hand, primary lesions in the DNA of rat (Rattus norvegicus hepatoma cells (HTC were observed through comet assaying after only 2 h of exposure. On considering the capacity to detect DNA damage of a different nature and of these cells to metabolize xenobiotics, we suggest the association of the two bioassays with these cell types, plant (Allium cepa and mammal (HTC cells, for more accurately assessing genotoxicity in environmental samples.

  3. Comparison of the effects of Mylabris and Acanthopanax senticosus on promising cancer marker polyamines in plasma of a Hepatoma-22 mouse model using HPLC-ESI-MS.

    Science.gov (United States)

    Wang, Qian; Wang, Yixiang; Liu, Ran; Yan, Xu; Li, Yujiao; Fu, Hui; Bi, Kaishun; Li, Qing

    2013-02-01

    A simple and sensitive method for the simultaneous determination of plasma concentrations of five polyamines in normal and Hepatoma-22 mice, and mice treated with Mylabris and Acanthopanax senticosus was developed by HPLC-ESI-MS. Male Kunming mice were divided into nine groups, a control group (inoculation without treatment), a positive group (Cyclophosphamide), treatment groups [Mylabris (4, 8, 16 mg/kg), Acanthopanax senticosus (6, 12, 24 g/kg)] and a normal group (without inoculation). Twenty-four hours after the last administration, plasma samples were collected. The derived polyamines were separated on a C(18) column by a gradient elution using methanol-water with excellent linearity within the range from 2.5 to 1000 ng/mL. Polyamines were confirmed as useful biochemical markers of hepatoma. The differences in anti-cancer therapeutic efficacy between Mylabris and Acanthopanax senticosus might contribute to the variability of polyamine levels in vivo. This HPLC-ESI-MS method was successfully applied to investigate the relationship between polyamines and cancer in mice and might be a useful method to test the activity of potential anti-tumor drugs. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Rapid HPLC-MS method for the simultaneous determination of tea catechins and folates.

    Science.gov (United States)

    Araya-Farias, Monica; Gaudreau, Alain; Rozoy, Elodie; Bazinet, Laurent

    2014-05-14

    An effective and rapid HPLC-MS method for the simultaneous separation of the eight most abundant tea catechins, gallic acid, and caffeine was developed. These compounds were rapidly separated within 9 min by a linear gradient elution using a Zorbax SB-C18 packed with sub 2 μm particles. This methodology did not require preparative and semipreparative HPLC steps. In fact, diluted tea samples can be easily analyzed using HPLC-MS as described in this study. The use of mass spectrometry detection for quantification of catechins ensured a higher specificity of the method. The percent relative standard deviation was generally lower than 4 and 7% for most of the compounds tested in tea drinks and tea extracts, respectively. Furthermore, the method provided excellent resolution for folate determination alone or in combination with catechins. To date, no HPLC method able to discriminate catechins and folates in a quick analysis has been reported in the literature.

  5. Deficiency of CCAAT/enhancer binding protein family DNA binding prevents malignant conversion of adenoma to carcinoma in NNK-induced lung carcinogenesis in the mouse

    Directory of Open Access Journals (Sweden)

    Kimura Shioko

    2012-12-01

    Full Text Available Abstract Background The CCAAT/enhancer binding proteins (C/EBPs play important roles in carcinogenesis of many tumors including the lung. Since multiple C/EBPs are expressed in lung, the combinatorial expression of these C/EBPs on lung carcinogenesis is not known. Methods A transgenic mouse line expressing a dominant negative A-C/EBP under the promoter of lung epithelial Clara cell secretory protein (CCSP gene in doxycycline dependent fashion was subjected to 4-(methylnitrosamino-1-(3-pyridyl-1-butanone (NNK-induced lung carcinogenesis bioassay in the presence and absence of doxycycline, and the effect of abolition of DNA binding activities of C/EBPs on lung carcinogenesis was examined. Results A-C/EBP expression was found not to interfere with tumor development; however, it suppressed the malignant conversion of adenoma to carcinoma during NNK-induced lung carcinogenesis. The results suggested that Ki67 may be used as a marker for lung carcinomas in mouse. Conclusions The DNA binding of C/EBP family members can be used as a potential molecular target for lung cancer therapy.

  6. Bioassay standardization for the detection of allelopathic compounds and environmental toxicants using lettuce

    Directory of Open Access Journals (Sweden)

    Mateus Salomão Simões

    2013-09-01

    Full Text Available The purpose of this study was to assess different experimental conditions to determine a protocol for bioassays based on seed germination and early seedling growth using lettuce (Lactuca sativa L. cv. Grand Rapids as indicator species. This protocol aims to provide support for the standardization of assays of various chemicals such as allelochemicals and environmental toxicants. The following tests were performed: time of germination, temperature, light, solution volume and Petri dish size. For each test (except for time of germination, the influence of the conditions investigated was determined by the endpoints germination percentage, germination speed index, root length, seedling fresh weight and total dry weight. The results showed that variations in the methods altered the results. It is recommended that bioassays using L. sativa L. cv. Grand Rapids be carried out for a minimum period of four days for assessments of both germination and initial growth and that the experimental conditions include a temperature of 20°C, 90-mm Petri dishes or larger, 0.1 mL cypsela solution, and continuous light or 12-hour photoperiod.

  7. Comparing the impacts of sediment-bound bifenthrin on aquatic macroinvertebrates in laboratory bioassays and field microcosms.

    Science.gov (United States)

    Boyle, Rhianna L; Hoak, Molly N; Pettigrove, Vincent J; Hoffmann, Ary A; Long, Sara M

    2016-11-01

    We conducted two laboratory bioassays and two field microcosm exposures with bifenthrin (a synthetic pyrethroid) in order to evaluate the capacity of single-species laboratory bioassays to predict lethal and sublethal impacts on aquatic invertebrates in microcosms. For the laboratory species, Chironomus tepperi, larval survival was reduced by 24% at 53.66µg/g OC, while adult emergence was reduced at concentrations of 33.33µg/g OC and higher, with a 61% decrease at 77.78µg/g OC and no emergence at 126.67µg/g OC. The abundance of several other microcosm taxa was reduced in the microcosms at a similar concentration range (33.33µg/g OC and above), however there was no impact on the abundance of the congeneric species, Chironomus oppositus. The differences in impacts between test systems were potentially due to both differing species sensitivity and the interaction of ambient temperature with bifenthrin toxicity. Bifenthrin also was associated with early emergence of Chironomus sp. in both test systems, at concentrations of 10µg/g OC and higher (laboratory) and 43.90µg/g OC (microcosm), and with a significant decrease in the proportion of C. oppositus males in a microcosm. These findings indicate that while laboratory bioassays accurately predict many impacts in the field, there are some limitations to the predictive capacity of these tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. Phytosterols from Spondias mombin Linn with Antimycobacterial ...

    African Journals Online (AJOL)

    Phytosterols from Spondias mombin Linn with Antimycobacterial Activities. ... African Journal of Biomedical Research ... Bioassay-guided fractionation of the methanol extract was carried out by Vacuum Liquid Chromatography (VLC) on Silica gel (230-400 mesh) and purification was done using HPLC and TLC. In vitro ...

  10. Colony-stimulating factor (CSF) radioimmunoassay: detection of a CSF subclass stimulating macrophage production

    International Nuclear Information System (INIS)

    Stanley, E.R.

    1979-01-01

    Colony-stimulating factors (CSFs) stimulate the differentiation of immature precursor cells to mature granulocytes and macrophages. Purified 125 I-labeled murine L cell CSF has been used to develop a radioimmunoassay (RIA) that detects a subclass of CSFs that stimulates macrophage production. Murine CSF preparations that contain this subclass of CSF compete for all of the CSF binding sites on anti-L cell CSF antibody. With the exception of mouse serum, which can contain inhibitors of the bioassay, there is complete correspondence between activities determined by RIA and those determined by bioassay. The RIA is slightly more sensitive than the bioassay, detecting approximately 0.3 fmol of purified L cell CSF. It can also detect this subclass of CSF in chickens, rats, and humans. In the mouse, the subclass is distinguished from other CSFs by a murine cell bioassay dose-response curve in which 90% of the response occurs over a 10-fold (rather than a 100-fold) increase in concentration, by stimulating the formations of colonies contaning a high proportion of mononuclear (rather than granulocytic) cells, and by certain physical characteristics

  11. Development of Reverse-Phase HPLC Method for Simultaneous ...

    African Journals Online (AJOL)

    Erah

    Purpose: To develop a simple, sensitive and rapid reverse phase HPLC method for the simultaneous analysis of metoprolol succinate and hydrochlorothiazide in a solid dosage form. Methods: The .... Extraction was carried out three times with.

  12. Analysis of taxines in Taxus plant material and cell cultures by hplc photodiode array and hplc-electrospray mass spectrometry

    NARCIS (Netherlands)

    Theodoridis, G.; Laskaris, G.; Rozendaal, E.L.M.; Verpoorte, R.

    2001-01-01

    A semi-purified Taxus baccata needles extract was analysed by RP-HPLC. More than 18 taxines and cinnamates were detected by photodiode array detection and LC-MS, 10 of them being positively identified. Furthermore, 10-deacetyl baccatin III (paclitaxel's main precursor) and other taxanes were also

  13. Development and application of bioassays for a site-specific risk assessment of contaminated soil

    NARCIS (Netherlands)

    Rila, J.-P.

    2008-01-01

    Soil risk assessment based on generic approaches is accompanied by a large number of uncertainties. In site-specific risk assessment aimed at identifying the actual effects on the ecosystem by using e.g. bioassays in soil elutriates and taking into account land-use these uncertainties can be largely

  14. An Inexpensive Digital Gradient Controller for HPLC.

    Science.gov (United States)

    Brady, James E.; Carr, Peter W.

    1983-01-01

    Use of gradient elution techniques in high performance liquid chromatography (HPLC) is often essential for direct separation of complex mixtures. Since most commercial controllers have features that are of marginal value for instructional purposes, a low-cost controller capable of illustrating essential features of gradient elution was developed.…

  15. Diagnostic doses and times for Phlebotomus papatasi and Lutzomyia longipalpis sand flies (Diptera: Psychodidae: Phlebotominae) using the CDC bottle bioassay to assess insecticide resistance.

    Science.gov (United States)

    Denlinger, David S; Creswell, Joseph A; Anderson, J Laine; Reese, Conor K; Bernhardt, Scott A

    2016-04-15

    Insecticide resistance to synthetic chemical insecticides is a worldwide concern in phlebotomine sand flies (Diptera: Psychodidae), the vectors of Leishmania spp. parasites. The CDC bottle bioassay assesses resistance by testing populations against verified diagnostic doses and diagnostic times for an insecticide, but the assay has been used limitedly with sand flies. The objective of this study was to determine diagnostic doses and diagnostic times for laboratory Lutzomyia longipalpis (Lutz & Nieva) and Phlebotomus papatasi (Scopoli) to ten insecticides, including pyrethroids, organophosphates, carbamates, and DDT, that are used worldwide to control vectors. Bioassays were conducted in 1,000-ml glass bottles each containing 10-25 sand flies from laboratory colonies of L. longipalpis or P. papatasi. Four pyrethroids, three organophosphates, two carbamates and one organochlorine, were evaluated. A series of concentrations were tested for each insecticide, and four replicates were conducted for each concentration. Diagnostic doses were determined only during the exposure bioassay for the organophosphates and carbamates. For the pyrethroids and DDT, diagnostic doses were determined for both the exposure bioassay and after a 24-hour recovery period. Both species are highly susceptible to the carbamates as their diagnostic doses are under 7.0 μg/ml. Both species are also highly susceptible to DDT during the exposure assay as their diagnostic doses are 7.5 μg/ml, yet their diagnostic doses for the 24-h recovery period are 650.0 μg/ml for Lu. longipalpis and 470.0 μg/ml for P. papatasi. Diagnostic doses and diagnostic times can now be incorporated into vector management programs that use the CDC bottle bioassay to assess insecticide resistance in field populations of Lu. longipalpis and P. papatasi. These findings provide initial starting points for determining diagnostic doses and diagnostic times for other sand fly vector species and wild populations using the CDC

  16. Novel assay of antibacterial components in manuka honey using lucigenin-chemiluminescence-HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, Koji, E-mail: koji180@pharm.showa-u.ac.jp; Haraya, Shiomi; Okubo, Sachie; Arakawa, Hidetoshi

    2017-02-15

    Five components (hydrogen peroxide, methylglyoxal, dihydroxyacetone, fructose and glucose) of New Zealand manuka honey (Leptospermum scoparium) were analyzed using lucigenin chemiluminescence high-performance liquid chromatography (lucigenin-CL-HPLC). We focused on active oxygen species produced from the components in order to easily detect these five components contained in manuka honey. H{sub 2}O{sub 2} and O{sub 2}{sup −} generated from these components were identified by lucigenin-CL and electron spin resonance (ESR), and the bactericidal effect of ROS was confirmed using E. coli. The previously reported assays for Manuka honey components have low specificities and require complicated preprocessing methods. As our results, the detection and identification of these components were possible within 30 min in lucigenin-CL-HPLC system, without any special treatment. It is considered that lucigenin-CL-HPLC is useful for the quality control and the analysis of various honey. - Highlights: • Antibacterial components in manuka honey by HPLC with lucigenin-CL. • Five antibacterial compounds measured via generation of reactive oxygen species. • Simple, sensitive and useful for quality control and analysis of antibacterial honey.

  17. Determination of blood cyanide by HPLC-MS.

    Science.gov (United States)

    Tracqui, A; Raul, J S; Géraut, A; Berthelon, L; Ludes, B

    2002-04-01

    An original high-performance liquid chromatographic-mass spectrometric (HPLC-MS) procedure was developed for the determination of cyanide (CN) in whole blood. After the addition of K13C15N as internal standard, blood was placed in a microdiffusion device, the inner well of which was filled with a mixture of taurine (50mM in water)/naphthalene-2,3-dicarboxaldehyde (NDA, 10mM in methanol)/methanol/ concentrated (approximately 20%) ammonia solution (25:25:45:5, v/v). Concentrated H2SO4 was added to the blood sample, and the microdiffusion chamber was sealed. After 30 min of gentle agitation, 2 microL of the contents of the inner vial were pipetted and directly injected onto a NovaPak C18 HPLC column. Separation was performed by a gradient of acetonitrile in 2mM NH4COOH, pH 3.0 buffer (35-80% in 10 min). Detection was done with a Perkin-Elmer Sciex API-100 mass analyzer with an ionspray interface, operated in the negative ionization mode. MS data were collected as either TIC or SIM at m/z (299 + 191) and (301 + 193) for the derivatives formed with CN and 13C15N, respectively. Inspired by previous works dealing with the complexation of CN by NDA + taurine to form a 1-cyano [f] benzoisoindole derivative analyzed by HPLC-fluorimetry, this method appears simple, rapid, and extremely specific. Limits of detection and quantitation for blood CN are 5 and 15 ng/mL, respectively. The use of 13C15N as internal standard allows the quantitation of CN with elegance and accuracy in comparison with previously reported methods.

  18. Bioassay requirements for 125I and 131I in medical, teaching and research institutions

    International Nuclear Information System (INIS)

    1983-09-01

    The more widespread use of radioactive isotopes of iodine (collectively referred to as radioiodines) as a research tool, coupled with their diagnostic and therapeutic uses in nuclear medicine, has resulted in an increased number of personnel who are exposed to these radioisotopes and who therefore should be monitored for internal radioiodine contamination. This document describes the minimum acceptable features of a bioassay programme which the Atomic Energy Control Board (AECB) requires to be available in institutions holding a prescribed substance licence authorising the use of significant quantities of 125 I or 131 I or both. A licensee may submit details of his own proposed bioassay programme to the AECB for approval. If such a programme fails to be approved, the programme described below shall be adhered to. This document does not deal with individuals who are likely to maintain a significant chronic thyroid burden of radioiodine. It is assumed that the radioiodine taken into the body is in a soluble, inorganic form (I 2 , iodide or iodate) or in an organic form (e.g. methyl iodide) which is metabolised in the body with a resultant release of iodide. Radioiodinated organic compounds which are not catabolised to iodide in the body to any significant degree are not the subject of this document, since the metabolism of the radioiodine will be dictated by the metabolism of the compound. This means that individuals whose only exposure to radioiodine is in the form of prepared radioiodinated compounds such as antigens and antibodies (e.g. individuals using radio immuno assay kits in which the antigen or antibody is supplied as radioiodinated material) are not required to participate in this bioassay programme for radioiodine

  19. Determination of cadmium and lead species and phytochelatins in pea (Pisum sativum) by HPLC-ICPMS and HPLC-ESIMSn

    International Nuclear Information System (INIS)

    Baralkiewicz, D.; Magorzata, K.; Piechalak, A.; Tomaszewska, B.

    2009-01-01

    Full text: Trace elements play an important role in the functioning of life on our planet. Some of them can be highly toxic, whereas others can be essential. These effects are very often related to particular form in which the element is present. Often these different chemical forms of a particular element or its compounds are referred to as 'species'. Cadmium and lead are widespread heavy metal pollutants released into the environment by human activities. The presence of Pb 2+ and Cd 2+ in the environment leads to a numerous disturbances in many metabolic processes in plants. Inhibition of growth is a major symptom. Hyphenated techniques, such as HPLC-ICPMS and HPLC-ESIMSn seem to be the best analytical instruments to study metal speciation in plants. In our study, we used hyphenated techniques to identify compounds engaged in Cd and Pb metabolism and to perform analysis of metal complexes induced in Pisum sativum exposed to cadmium and lead. These identified compounds might be valuable source of information to study metal accumulation mechanism for bioremediation processes. (author)

  20. Toxicity assessment using different bioassays and microbial biosensors.

    Science.gov (United States)

    Hassan, Sedky H A; Van Ginkel, Steven W; Hussein, Mohamed A M; Abskharon, Romany; Oh, Sang-Eun

    2016-01-01

    Toxicity assessment of water streams, wastewater, and contaminated sediments, is a very important part of environmental pollution monitoring. Evaluation of biological effects using a rapid, sensitive and cost effective method can indicate specific information on ecotoxicity assessment. Recently, different biological assays for toxicity assessment based on higher and lower organisms such as fish, invertebrates, plants and algal cells, and microbial bioassays have been used. This review focuses on microbial biosensors as an analytical device for environmental, food, and biomedical applications. Different techniques which are commonly used in microbial biosensing include amperometry, potentiometry, conductometry, voltammetry, microbial fuel cells, fluorescence, bioluminescence, and colorimetry. Examples of the use of different microbial biosensors in assessing a variety of environments are summarized. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Isolation of Fungi from Heterodera glycines and in vitro Bioassays for Their Antagonism to Eggs.

    Science.gov (United States)

    Meyer, S L; Huettel, R N; Sayre, R M

    1990-10-01

    Twenty fungi were assayed in vitro for antagonism to eggs of Heterodera glycines. Eight of the fungi were isolated from cysts or eggs of H. glycines during the current study, one was isolated from Panagrellus redivivus, and eleven were obtained from other researchers or collections. The bioassays were conducted on eggs from nematodes that had been grown monoxenically on excised root tips. Phoma chrysanthemicola, one strain of Verticillium chlamydosporium, and one strain of V. lecanii caused a decrease (P Trichoderma polysporum infected live eggs but enhanced (P Fusarium sp., Neocosmospora vasinfecta, Scytalidium fulvum, Trichoderma harzianum (two strains), V. chlamydosporium (one strain), V. lecanii (three strains), and an unidentified fungus did not measurably affect egg viability, even though hyphae of five of these fungi were seen in live eggs. The bioassay provides a useful step in the selection of a biological control agent for this major nematode pest.

  2. Fluconazole Pharmacokinetics in Galleria mellonella Larvae and Performance Evaluation of a Bioassay Compared to Liquid Chromatography-Tandem Mass Spectrometry for Hemolymph Specimens

    DEFF Research Database (Denmark)

    Astvad, Karen Marie Thyssen; Meletiadis, Joseph; Whalley, Sarah

    2017-01-01

    The invertebrate model organism Galleria mellonella can be used to assess the efficacy of treatment of fungal infection. The fluconazole dose best mimicking human exposure during licensed dosing is unknown. We validated a bioassay for fluconazole detection in hemolymph and determined...... the fluconazole pharmacokinetics and pharmacodynamics in larval hemolymph in order to estimate a humanized dose for future experiments. A bioassay using 4-mm agar wells, 20 μl hemolymph, and the hypersusceptible Candida albicans DSY2621 was established and compared to a validated liquid chromatography-tandem mass...... spectrometry (LC-MS-MS) method. G. mellonella larvae were injected with fluconazole (5, 10, and 20 mg/kg of larval weight), and hemolymph was harvested for 24 h for pharmacokinetics calculations. The exposure was compared to the human exposure during standard licensed dosing. The bioassay had a linear standard...

  3. Purple Corn (Zea mays L.) Phenolic Compounds Profile and Its Assessment as an Agent Against Oxidative Stress in Isolated Mouse Organs

    Science.gov (United States)

    Ramos-Escudero, Fernando; Muñoz, Ana María; Alvarado-Ortíz, Carlos; Alvarado, Ángel

    2012-01-01

    Abstract This study was designed to determine the contents of total polyphenols, flavonoids, flavonols, flavanols, and anthocyanins of purple corn (Zea mays L.) extracts obtained with different methanol:water concentrations, acidified with 1% HCl (1 N). Another objective was to determine the antioxidant activity by 1,1-diphenyl-2-picrylhydrazyl (DPPH), 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), ferric reducing antioxidant power (FRAP), and deoxyribose assay, individual phenolic compounds by high-performance liquid chromatography (HPLC), and endogenous antioxidant enzyme (superoxide dismutase [SOD], catalase [CAT], and total peroxidase [TPX]) activity and lipid peroxidation activity (thiobarbituric acid–reactive substances [TBARS] assay) in isolated mouse organs. Overall, the highest total content of polyphenols, anthocyanins, flavonoids, flavonols, and flavanols was obtained with the 80:20 methanol:water extract, acidified with 1% HCl (1 N). The 50% inhibitory concentration values obtained by the DPPH and ABTS assays with this extract were 66.3 μg/mL and 250 μg/mL, respectively. The antioxidant activity by the FRAP assay was 26.1 μM Trolox equivalents/g, whereas the deoxyribose assay presented 93.6% inhibition. Because of these results, the 80:20 methanol:water extract, acidified with 1% HCl (1 N), was used for the remaining tests. Eight phenolic compounds were identified by HPLC: chlorogenic acid, caffeic acid, rutin, ferulic acid, morin, quercetin, naringenin, and kaempferol. Furthermore, it was observed that the purple corn extract was capable of significantly reducing lipid peroxidation (lower malondialdehyde [MDA] concentrations by the TBARS assay) and at the same time increasing endogenous antioxidant enzyme (CAT, TPX, and SOD) activities in isolated mouse kidney, liver, and brain. On the basis of the results, it was concluded that the purple corn extract contained various bioactive phenolic compounds that exhibited

  4. Purple corn (Zea mays L.) phenolic compounds profile and its assessment as an agent against oxidative stress in isolated mouse organs.

    Science.gov (United States)

    Ramos-Escudero, Fernando; Muñoz, Ana María; Alvarado-Ortíz, Carlos; Alvarado, Ángel; Yáñez, Jaime A

    2012-02-01

    This study was designed to determine the contents of total polyphenols, flavonoids, flavonols, flavanols, and anthocyanins of purple corn (Zea mays L.) extracts obtained with different methanol:water concentrations, acidified with 1% HCl (1 N). Another objective was to determine the antioxidant activity by 1,1-diphenyl-2-picrylhydrazyl (DPPH), 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), ferric reducing antioxidant power (FRAP), and deoxyribose assay, individual phenolic compounds by high-performance liquid chromatography (HPLC), and endogenous antioxidant enzyme (superoxide dismutase [SOD], catalase [CAT], and total peroxidase [TPX]) activity and lipid peroxidation activity (thiobarbituric acid-reactive substances [TBARS] assay) in isolated mouse organs. Overall, the highest total content of polyphenols, anthocyanins, flavonoids, flavonols, and flavanols was obtained with the 80:20 methanol:water extract, acidified with 1% HCl (1 N). The 50% inhibitory concentration values obtained by the DPPH and ABTS assays with this extract were 66.3 μg/mL and 250 μg/mL, respectively. The antioxidant activity by the FRAP assay was 26.1 μM Trolox equivalents/g, whereas the deoxyribose assay presented 93.6% inhibition. Because of these results, the 80:20 methanol:water extract, acidified with 1% HCl (1 N), was used for the remaining tests. Eight phenolic compounds were identified by HPLC: chlorogenic acid, caffeic acid, rutin, ferulic acid, morin, quercetin, naringenin, and kaempferol. Furthermore, it was observed that the purple corn extract was capable of significantly reducing lipid peroxidation (lower malondialdehyde [MDA] concentrations by the TBARS assay) and at the same time increasing endogenous antioxidant enzyme (CAT, TPX, and SOD) activities in isolated mouse kidney, liver, and brain. On the basis of the results, it was concluded that the purple corn extract contained various bioactive phenolic compounds that exhibited considerable in vitro

  5. Using a macroalgal δ15N bioassay to detect cruise ship waste water effluent inputs

    International Nuclear Information System (INIS)

    Kaldy, James

    2011-01-01

    Highlights: → Green macroalgae exposed to nutrient solutions exhibited changes in tissue 15 N signatures. → Macroalgae exhibited no fractionation with NO 3 and slight fractionation with NH 4 . → Algae exposed to cruise ship waste water had increased tissue δ 15 N indicating a heavy N source. → Field bioassays exhibited decreased δ 15 N indicating isotopically light riverine δ 15 N-NO 3 was likely the dominant N source. → Algal bioassays could not detect a δ 15 N cruise ship waste water signal in this system. - Abstract: Green macroalgae bioassays were used to determine if the δ 15 N signature of cruise ship waste water effluent (CSWWE) could be detected in a small harbor. Opportunistic green macroalgae (Ulva spp.) were collected, cultured under nutrient depleted conditions and characterized with regard to N content and δ 15 N. Samples of algae were used in controlled incubations to evaluate the direction of isotope shift from exposure to CSWWE. Algae samples exposed to CSWWE exhibited an increase of 1-2.5 per mille in δ 15 N values indicating that the CSWWE had an enriched isotope signature. In contrast, algae samples exposed to field conditions exhibited a significant decrease in the observed δ 15 N indicating that a light N source was used. Isotopically light, riverine nitrogen derived from N 2 -fixing trees in the watershed may be a N source utilized by algae. These experiments indicate that the δ 15 N CSWWE signature was not detectable under the CSWWE loading conditions of this experiment.

  6. Screening and Analysis of the Potential Bioactive Components of Poria cocos (Schw. Wolf by HPLC and HPLC-MSn with the Aid of Chemometrics

    Directory of Open Access Journals (Sweden)

    Ling-Fang Wu

    2016-02-01

    Full Text Available The aim of the present study was to establish a new method based on Similarity Analysis (SA, Cluster Analysis (CA and Principal Component Analysis (PCA to determine the quality of different samples of Poria cocos (Schw. Wolf obtained from Yunnan, Hubei, Guizhou, Fujian, Henan, Guangxi, Anhui and Sichuan in China. For this purpose 15 samples from the different habitats were analyzed by HPLC-PAD and HPLC-MSn. Twenty-three compounds were detected by HPLC-MSn, of which twenty compounds were tentatively identified by comparing their retention times and mass spectrometry data with that of reference compounds and reviewing the literature. The characteristic fragmentations were summarized. 3-epi-Dehydrotumulosic acid (F13, 3-oxo-16α,25-dihydroxylanosta-7,9(11,24(31-trien-21-oic acid (F4, 3-oxo-6,16α-dihydroxylanosta-7,9(11,24(31-trien-21-oic acid (F7 and dehydropachymic acid (F15 were deemed to be suitable marker compounds to distinguish between samples of different quality according to CA and PCA. This study provides helpful chemical information for further anti-tumor activity and active mechanism research on P. cocos. The results proved that fingerprint combined with a chemometric approach is a simple, rapid and effective method for the quality discrimination of P. cocos.

  7. Investigating Pigment Radicals in Black Rice Using HPLC and Multi-EPR.

    Science.gov (United States)

    Nakagawa, Kouichi; Maeda, Hayato

    2017-01-01

    We investigated the location and distribution of paramagnetic species in black and white rice using electron paramagnetic resonance (EPR), X-band (9 GHz) EPR imaging (EPRI), and HPLC. EPR primarily detected two paramagnetic species in black rice, which were identified as a stable radical and Mn 2+ species, based on the g values and hyperfine components of the EPR signals. The signal from the stable radical appeared at g ≈ 2.00 and was relatively strong and stable. Subsequent noninvasive two-dimensional (2D) EPRI revealed that this stable radical was primarily located in the pigmented region of black rice, while very few radicals were observed in the rice interior. Pigments extracted from black rice were analyzed using HPLC; the major compound was found to be cyanidin-3-glucoside. EPR and HPLC results indicate that the stable radical was only found within the pigmented region of the rice, and that it could either be cyanidin-3-glucoside, or one of its oxidative decomposition products.

  8. A fatal forensic intoxication with fenarimol: analysis by HPLC/DAD/MSD.

    Science.gov (United States)

    Proença, P; Pinho Marques, E; Teixeira, H; Castanheira, F; Barroso, M; Avila, S; Vieira, D N

    2003-04-23

    Fenarimol (Rubigan) is a pyrimidine ergosterol biosynthesis inhibitor used as a systemic fungicide. The authors present a fatal fenarimol intoxication case analysed in the Forensic Toxicology Service of the National Institute of Legal Medicine. The results were used to compare two different HPLC techniques, regarding selectivity and sensitivity: an HPLC system with a diode array detector (DAD) and an HPLC system with a DAD and a mass spectrometry detector (MSD) with an electrospray interface. All biological samples were submitted to a solid-phase extraction procedure. The detection and quantification limits of fenarimol, linearity, precision and accuracy were evaluated. The fenarimol concentration levels determined were of 89.0 mg/ml in gastric contents, 1.9 mg/g in liver and 0.4 mg/g in kidney. Blood was not available at autopsy. No published data related to fenarimol self-poisoning were found, so it was not possible to interpret the results obtained by comparison with toxic/lethal levels.

  9. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    Science.gov (United States)

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Bioassays for the determination of nitrification inhibition

    Energy Technology Data Exchange (ETDEWEB)

    Grunditz, Camilla

    1999-07-01

    Requirements for nitrogen reduction in wastewater treatment plants were introduced in Sweden in the early 1990's. This was a governmental move to reduce the nitrogen discharges to the Baltic and Kattegat in order to prevent eutrophication. The nitrification process in wastewater treatment plants is performed by nitrifying bacteria. These are susceptible to inhibition and it is of great importance that the influent water does not contain toxic compounds. Therefore, there is a need for assays for the determination of nitrification inhibition. This thesis describes the development and applications of such bioassays. Pure cultures of Nitrosomonas sp. and Nitrobacter sp. were isolated from activated sludge of a wastewater treatment plant. These cultures were used as test organisms in the development of bioassays for nitrification inhibition measurements. The assays are based on two different principles; cell suspensions of the bacteria, performed in test tubes, and mediated amperometric biosensors with the bacteria immobilised. Ammonia oxidation and nitrite oxidation are studied separately without interference from other organisms, which makes it easier to interpret the results. The cell suspension assays were applied to samples of industrial and municipal wastewater. The Nitrosomonas and Nitrobacter assays showed to have different inhibition patterns. A large percentage of the Swedish municipal wastewater treatment plants were found to receive inhibitory influent water, but the inhibition level was generally low. Compared to an assay based on activated sludge, the screening method, the pure culture assays found more samples of influent water strongly inhibitory or stimulating. The highest correlation was found between the screening method and the Nitrosomonas assay. The Nitrobacter assay was found to be the most sensitive method. Assessment of toxicity of a number of chemical substances was studied using the biosensors, together with the cell suspension assays

  11. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    International Nuclear Information System (INIS)

    Jitaru, Petru; Goenaga-Infante, Heidi; Vaslin-Reimann, Sophie; Fisicaro, Paola

    2010-01-01

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  12. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jitaru, Petru, E-mail: Petru.Jitaru@lne.fr [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France); Goenaga-Infante, Heidi [LGC Limited, Queens Road, Teddington, TW11 OLY, Middlesex (United Kingdom); Vaslin-Reimann, Sophie; Fisicaro, Paola [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France)

    2010-01-11

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  13. HPLC quantification of phenolic content and assessment of ...

    African Journals Online (AJOL)

    omotayo

    2016-03-02

    Mar 2, 2016 ... detection (HPLC-DAD) fingerprinting of phenolic content. Furthermore, the .... Briefly, deionised water (0.5 ml) and 125 μl of Folin–Colcalteu reagent were added to ..... to be organ-specific and can leak from a damaged or an.

  14. Novel bioassay demonstrates attraction of the white potato cyst nematode Globodera pallida (Stone) to non-volatile and volatile host plant cues.

    Science.gov (United States)

    Farnier, Kevin; Bengtsson, Marie; Becher, Paul G; Witzell, Johanna; Witzgall, Peter; Manduríc, Sanja

    2012-06-01

    Potato cyst nematodes (PCNs) are a major pest of solanaceous crops such as potatoes, tomatoes, and eggplants and have been widely studied over the last 30 years, with the majority of earlier studies focusing on the identification of natural hatching factors. As a novel approach, we focused instead on chemicals involved in nematode orientation towards its host plant. A new dual choice sand bioassay was designed to study nematode responses to potato root exudates (PRE). This bioassay, conducted together with a traditional hatching bioassay, showed that biologically active compounds that induce both hatching and attraction of PCNs can be collected by water extraction of incised potato roots. Furthermore, our results demonstrated that PCN also were attracted by potato root volatiles. Further work is needed to fully understand how PCNs use host plant chemical cues to orientate towards hosts. Nevertheless, the simple attraction assay used in this study provides an important tool for the identification of host-emitted attractants.

  15. Botulinum Neurotoxins: Qualitative and Quantitative Analysis Using the Mouse Phrenic Nerve Hemidiaphragm Assay (MPN

    Directory of Open Access Journals (Sweden)

    Hans Bigalke

    2015-11-01

    Full Text Available The historical method for the detection of botulinum neurotoxin (BoNT is represented by the mouse bioassay (MBA measuring the animal survival rate. Since the endpoint of the MBA is the death of the mice due to paralysis of the respiratory muscle, an ex vivo animal replacement method, called mouse phrenic nerve (MPN assay, employs the isolated N. phrenicus-hemidiaphragm tissue. Here, BoNT causes a dose-dependent characteristic decrease of the contraction amplitude of the indirectly stimulated muscle. Within the EQuATox BoNT proficiency 13 test samples were analysed using the MPN assay by serial dilution to a bath concentration resulting in a paralysis time within the range of calibration curves generated with BoNT/A, B and E standards, respectively. For serotype identification the diluted samples were pre-incubated with polyclonal anti-BoNT/A, B or E antitoxin or a combination of each. All 13 samples were qualitatively correctly identified thereby delivering superior results compared to single in vitro methods like LFA, ELISA and LC-MS/MS. Having characterized the BoNT serotype, the final bath concentrations were calculated using the calibration curves and then multiplied by the respective dilution factor to obtain the sample concentration. Depending on the source of the BoNT standards used, the quantitation of ten BoNT/A containing samples delivered a mean z-score of 7 and of three BoNT/B or BoNT/E containing samples z-scores <2, respectively.

  16. Centralized mouse repositories.

    Science.gov (United States)

    Donahue, Leah Rae; Hrabe de Angelis, Martin; Hagn, Michael; Franklin, Craig; Lloyd, K C Kent; Magnuson, Terry; McKerlie, Colin; Nakagata, Naomi; Obata, Yuichi; Read, Stuart; Wurst, Wolfgang; Hörlein, Andreas; Davisson, Muriel T

    2012-10-01

    Because the mouse is used so widely for biomedical research and the number of mouse models being generated is increasing rapidly, centralized repositories are essential if the valuable mouse strains and models that have been developed are to be securely preserved and fully exploited. Ensuring the ongoing availability of these mouse strains preserves the investment made in creating and characterizing them and creates a global resource of enormous value. The establishment of centralized mouse repositories around the world for distributing and archiving these resources has provided critical access to and preservation of these strains. This article describes the common and specialized activities provided by major mouse repositories around the world.

  17. Plasmonically amplified fluorescence bioassay with microarray format

    Science.gov (United States)

    Gogalic, S.; Hageneder, S.; Ctortecka, C.; Bauch, M.; Khan, I.; Preininger, Claudia; Sauer, U.; Dostalek, J.

    2015-05-01

    Plasmonic amplification of fluorescence signal in bioassays with microarray detection format is reported. A crossed relief diffraction grating was designed to couple an excitation laser beam to surface plasmons at the wavelength overlapping with the absorption and emission bands of fluorophore Dy647 that was used as a label. The surface of periodically corrugated sensor chip was coated with surface plasmon-supporting gold layer and a thin SU8 polymer film carrying epoxy groups. These groups were employed for the covalent immobilization of capture antibodies at arrays of spots. The plasmonic amplification of fluorescence signal on the developed microarray chip was tested by using interleukin 8 sandwich immunoassay. The readout was performed ex situ after drying the chip by using a commercial scanner with high numerical aperture collecting lens. Obtained results reveal the enhancement of fluorescence signal by a factor of 5 when compared to a regular glass chip.

  18. Identification and characterization of antifungal compounds using a Saccharomyces cerevisiae reporter bioassay.

    Directory of Open Access Journals (Sweden)

    Brad Tebbets

    Full Text Available New antifungal drugs are urgently needed due to the currently limited selection, the emergence of drug resistance, and the toxicity of several commonly used drugs. To identify drug leads, we screened small molecules using a Saccharomyces cerevisiae reporter bioassay in which S. cerevisiae heterologously expresses Hik1, a group III hybrid histidine kinase (HHK from Magnaporthe grisea. Group III HHKs are integral in fungal cell physiology, and highly conserved throughout this kingdom; they are absent in mammals, making them an attractive drug target. Our screen identified compounds 13 and 33, which showed robust activity against numerous fungal genera including Candida spp., Cryptococcus spp. and molds such as Aspergillus fumigatus and Rhizopus oryzae. Drug-resistant Candida albicans from patients were also highly susceptible to compounds 13 and 33. While the compounds do not act directly on HHKs, microarray analysis showed that compound 13 induced transcripts associated with oxidative stress, and compound 33, transcripts linked with heavy metal stress. Both compounds were highly active against C. albicans biofilm, in vitro and in vivo, and exerted synergy with fluconazole, which was inactive alone. Thus, we identified potent, broad-spectrum antifungal drug leads from a small molecule screen using a high-throughput, S. cerevisiae reporter bioassay.

  19. Reporter gene bioassays in environmental analysis.

    Science.gov (United States)

    Köhler, S; Belkin, S; Schmid, R D

    2000-01-01

    In parallel to the continuous development of increasingly more sophisticated physical and chemical analytical technologies for the detection of environmental pollutants, there is a progressively more urgent need also for bioassays which report not only on the presence of a chemical but also on its bioavailability and its biological effects. As a partial fulfillment of that need, there has been a rapid development of biosensors based on genetically engineered bacteria. Such microorganisms typically combine a promoter-operator, which acts as the sensing element, with reporter gene(s) coding for easily detectable proteins. These sensors have the ability to detect global parameters such as stress conditions, toxicity or DNA-damaging agents as well as specific organic and inorganic compounds. The systems described in this review, designed to detect different groups of target chemicals, vary greatly in their detection limits, specificity, response times and more. These variations reflect on their potential applicability which, for most of the constructs described, is presently rather limited. Nevertheless, present trends promise that additional improvements will make microbial biosensors an important tool for future environmental analysis.

  20. Annotating Human P-Glycoprotein Bioassay Data.

    Science.gov (United States)

    Zdrazil, Barbara; Pinto, Marta; Vasanthanathan, Poongavanam; Williams, Antony J; Balderud, Linda Zander; Engkvist, Ola; Chichester, Christine; Hersey, Anne; Overington, John P; Ecker, Gerhard F

    2012-08-01

    Huge amounts of small compound bioactivity data have been entering the public domain as a consequence of open innovation initiatives. It is now the time to carefully analyse existing bioassay data and give it a systematic structure. Our study aims to annotate prominent in vitro assays used for the determination of bioactivities of human P-glycoprotein inhibitors and substrates as they are represented in the ChEMBL and TP-search open source databases. Furthermore, the ability of data, determined in different assays, to be combined with each other is explored. As a result of this study, it is suggested that for inhibitors of human P-glycoprotein it is possible to combine data coming from the same assay type, if the cell lines used are also identical and the fluorescent or radiolabeled substrate have overlapping binding sites. In addition, it demonstrates that there is a need for larger chemical diverse datasets that have been measured in a panel of different assays. This would certainly alleviate the search for other inter-correlations between bioactivity data yielded by different assay setups.

  1. Seroprevalensi Toxoplasma gondii pada Kambing dan Bioassay Patogenitasnya pada Kucing

    Directory of Open Access Journals (Sweden)

    Ni Made Yunik Novita Dewi Dewi

    2013-11-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE The study aimed to determine seroprevalence of Toxoplasmosis in goats sloughtered at Kampung Jawa, Denpasar, Bali and to evaluate their pathogenicities through bioassay in cats.One hundred serums and meats of goats were collected. Anti-Toxoplasma gondii antibody was determined using Indirect Haemaglutination (IHA test. The pathogenicity bioassay of Toxoplasma gondii was carried out through inoculating the meats of goats which had seropositive of Toxoplasma gondii to the cats. The pathogenicity was evaluated using the intensity of oocyte sheding from the cats. The result showed that the seroprevalence of Toxoplasmosis was 46%. There was not significant difference between pathogenicity of Toxoplasma gondii in cat inoculated with meat of goat which had a high and low titer of antibody against Toxoplasma gondii. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; text-align:justify; line-height:150%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin;}

  2. Simultaneous HPLC quantitative analysis of mangostin derivatives in Tetragonula pagdeni propolis extracts

    Directory of Open Access Journals (Sweden)

    Sumet Kongkiatpaiboon

    2016-04-01

    Full Text Available Propolis has been used as indigenous medicine for curing numerous maladies. The one that is of ethnopharmacological use is stingless bee propolis from Tetragonula pagdeni. A simultaneous high-performance liquid chromatography (HPLC investigation was developed and validated to determine the contents of bioactive compounds: 3-isomangostin, gamma-mangostin, beta-mangostin, and alpha-mangostin. HPLC analysis was effectively performed using a Hypersil BDS C18 column, with the gradient elution of methanol–0.2% formic acid and a flow rate of 1 ml/min, at 25 °C and detected at 245 nm. Parameters for the validation included accuracy, precision, linearity, and limits of quantitation and detection. The developed HPLC technique was precise, with lower than 2% relative standard deviation. The recovery values of 3-isomangostin, gamma-mangostin, beta-mangostin, and alpha-mangostin in the extracts were 99.98%, 99.97%, 98.98% and 99.19%, respectively. The average contents of these mixtures in the propolis extracts collected from different seasons were 0.127%, 1.008%, 0.323% and 2.703% (w/w, respectively. The developed HPLC technique was suitable and practical for the simultaneous analysis of these mangostin derivatives in T. pagdeni propolis and would be a valuable guidance for the standardization of its pharmaceutical products.

  3. Brief on -Hyphenated Methods of HPLC for Determining the Presence of Solutes.

    Directory of Open Access Journals (Sweden)

    Mohamad Taleuzzaman

    2017-02-01

    Full Text Available HPLC is the tool in liquid chromatography is unique because of particle size, smaller particle in the stationary phase, increase efficiency of a separation. However, if the particles are made smaller, capillary action increases and it becomes more difficult to drain the column under gravity. For quantitative analysis different types of detector is used in conjunction with HPLC which give precise and accurate result and it is apply according to the nature of the substance. Various types of detectors used in HPLC are mass spectrometry, infrared spectroscopy, visible spectroscopy, ultraviolet spectroscopy, fluorescence spectroscopy, nuclear magnetic resonance, conductivity measurement, and refractive index measurement. Each detector has its assets, limitations and sample types for which it is most effective. The recent development of the so-called hyphenated techniques has improved the ability to separate and identify multiple entities within a mixture.

  4. Assessing soil ecotoxicity of methyl tert-butyl ether using earthworm bioassay; closed soil microcosm test for volatile organic compounds

    International Nuclear Information System (INIS)

    An, Youn-Joo

    2005-01-01

    An earthworm bioassay was conducted to assess ecotoxicity in methyl tert-butyl ether (MTBE)-amended soils. Ecotoxicity of MTBE to earthworms was evaluated by a paper contact method, natural field soil test, and an OECD artificial soil test. All tests were conducted in closed systems to prevent volatilization of MTBE out of test units. Test earthworm species were Perionyx excavatus and Eisenia andrei. Mortality and abnormal morphology of earthworms exposed to different concentrations of MTBE were examined. MTBE was toxic to both earthworm species and the severity of response increased with increasing MTBE concentrations. Perionyx excavatus was more sensitive to MTBE than Eisenia andrei in filter papers and two different types of soils. MTBE toxicity was more severe in OECD artificial soils than in field soils, possibly due to the burrowing behavior of earthworms into artificial soils. The present study demonstrated that ecotoxicity of volatile organic compounds such as MTBE can be assessed using an earthworm bioassay in closed soil microcosm with short-term exposure duration. - Earthworm bioassay can be a good protocol to assess soil ecotoxicity of volatile organic compounds such as MTBE

  5. Quantitative HPLC determination of [99mTc]-pertechnetate in radiopharmaceuticals and biological samples: Pt. 1

    International Nuclear Information System (INIS)

    Tianze Zhou; Hirth, W.W.; Heineman, W.R.; Deutsch, Edward

    1988-01-01

    Techniques have been developed which allow HPLC (high performance liquid chromatography) to be used for the quantitative determination of [ 99m Tc]pertechnetate in radiopharmaceuticals and biological samples. An instrumental technique accounts for 99m Tc species which do not elute from the HPLC column, while a chemical technique obviates interferences caused by Sn(II). These two techniques are incorporated into an anion exchange HPLC procedure which is applied to the determination of [ 99m Tc]pertechnetate in 99m Tc-diphosphonate radiopharmaceuticals and biological samples. (author)

  6. Detection of anabolic androgenic steroid abuse in doping control using mammalian reporter gene bioassays.

    Science.gov (United States)

    Houtman, Corine J; Sterk, Saskia S; van de Heijning, Monique P M; Brouwer, Abraham; Stephany, Rainer W; van der Burg, Bart; Sonneveld, Edwin

    2009-04-01

    Anabolic androgenic steroids (AAS) are a class of steroid hormones related to the male hormone testosterone. They are frequently detected as drugs in sport doping control. Being similar to or derived from natural male hormones, AAS share the activation of the androgen receptor (AR) as common mechanism of action. The mammalian androgen responsive reporter gene assay (AR CALUX bioassay), measuring compounds interacting with the AR can be used for the analysis of AAS without the necessity of knowing their chemical structure beforehand, whereas current chemical-analytical approaches may have difficulty in detecting compounds with unknown structures, such as designer steroids. This study demonstrated that AAS prohibited in sports and potential designer AAS can be detected with this AR reporter gene assay, but that also additional steroid activities of AAS could be found using additional mammalian bioassays for other types of steroid hormones. Mixtures of AAS were found to behave additively in the AR reporter gene assay showing that it is possible to use this method for complex mixtures as are found in doping control samples, including mixtures that are a result of multi drug use. To test if mammalian reporter gene assays could be used for the detection of AAS in urine samples, background steroidal activities were measured. AAS-spiked urine samples, mimicking doping positive samples, showed significantly higher androgenic activities than unspiked samples. GC-MS analysis of endogenous androgens and AR reporter gene assay analysis of urine samples showed how a combined chemical-analytical and bioassay approach can be used to identify samples containing AAS. The results indicate that the AR reporter gene assay, in addition to chemical-analytical methods, can be a valuable tool for the analysis of AAS for doping control purposes.

  7. Assessment of sediment contamination by spermiotoxicity and embryotoxicity bioassays with sea urchins (Paracentrotus lividus) and oysters (Crassostrea gigas).

    Science.gov (United States)

    Geffard, O; Budzinski, H; Augagneur, S; Seaman, M N; His, E

    2001-07-01

    Gametes (sperm) and fertilized eggs (embryos) of the Mediterranean sea urchin, Paracentrotus lividus, and the Japanese oyster, Crassostrea gigas, were used to investigate the toxicity of two marine sediments, one polluted by polycyclic aromatic hydrocarbons (PAH) and the other by heavy metals. The sediment samples were freeze-dried for storage, and three different treatments were used for analysis: whole sediment, unfiltered elutriate, and filtered elutriate. The two sediments were toxic to sea urchin spermatozoa but not to oyster spermatozoa, and embryotoxicity was almost always the more sensitive endpoint for toxicity assessment. As a rule, whole sediment was more toxic than the elutriates by nearly two orders of magnitude. With respect to embryotoxicity, the whole sediments and the elutriates of the PAH-contaminated sediment were more toxic to oyster embryos, whereas the elutriates of the sediment polluted by heavy metals had stronger effects on sea urchin embryos. The results confirm that bioassays with Japanese oyster embryos provide a more sensitive appraisal of toxicity in the marine environment than bioassays with other developmental stages. As a whole, Mediterranean sea urchins and Japanese oysters were similar in overall sensitivity and are therefore both equally suited as bioassay organisms, but tests with oysters are more reproducible because of the better performance of the controls.

  8. Evaluation of genotoxic effects caused by extracts of chlorinated drinking water using a combination of three different bioassays.

    Science.gov (United States)

    Zeng, Qiang; Zhang, Shao-Hui; Liao, Jing; Miao, Dong-Yue; Wang, Xin-Yi; Yang, Pan; Yun, Luo-Jia; Liu, Ai-Lin; Lu, Wen-Qing

    2015-10-15

    Potential genotoxic effects of chlorinated drinking water now are of a great concern. In this study, raw water, finished water, and tap water from a water plant in Wuhan, China were collected in two different sampling times of the year (January and July). Genotoxic effects of water extracts were evaluated using a combination of three different bioassays: SOS/umu test, HGPRT gene mutation assay, and micronucleus assay, which were separately used to detect DNA damage, gene mutation, and chromosome aberration. The results of three different bioassays showed that all water samples in January and July induced at least one types of genotoxic effects, of which the DNA-damage effects were all detectable. The levels of DNA-damage effects and gene-mutation effects of finished water and tap water in January were higher than those in July. Chlorination could increase the DNA-damage effects of drinking water in January and the gene-mutation effects of drinking water in both January and July, but did not increase the chromosome-aberration effects of drinking water in both January and July. Our results highlighted the importance of using a combination of different bioassays to evaluate the genotoxicity of water samples in different seasons. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Evolving BioAssay Ontology (BAO): modularization, integration and applications.

    Science.gov (United States)

    Abeyruwan, Saminda; Vempati, Uma D; Küçük-McGinty, Hande; Visser, Ubbo; Koleti, Amar; Mir, Ahsan; Sakurai, Kunie; Chung, Caty; Bittker, Joshua A; Clemons, Paul A; Brudz, Steve; Siripala, Anosha; Morales, Arturo J; Romacker, Martin; Twomey, David; Bureeva, Svetlana; Lemmon, Vance; Schürer, Stephan C

    2014-01-01

    The lack of established standards to describe and annotate biological assays and screening outcomes in the domain of drug and chemical probe discovery is a severe limitation to utilize public and proprietary drug screening data to their maximum potential. We have created the BioAssay Ontology (BAO) project (http://bioassayontology.org) to develop common reference metadata terms and definitions required for describing relevant information of low-and high-throughput drug and probe screening assays and results. The main objectives of BAO are to enable effective integration, aggregation, retrieval, and analyses of drug screening data. Since we first released BAO on the BioPortal in 2010 we have considerably expanded and enhanced BAO and we have applied the ontology in several internal and external collaborative projects, for example the BioAssay Research Database (BARD). We describe the evolution of BAO with a design that enables modeling complex assays including profile and panel assays such as those in the Library of Integrated Network-based Cellular Signatures (LINCS). One of the critical questions in evolving BAO is the following: how can we provide a way to efficiently reuse and share among various research projects specific parts of our ontologies without violating the integrity of the ontology and without creating redundancies. This paper provides a comprehensive answer to this question with a description of a methodology for ontology modularization using a layered architecture. Our modularization approach defines several distinct BAO components and separates internal from external modules and domain-level from structural components. This approach facilitates the generation/extraction of derived ontologies (or perspectives) that can suit particular use cases or software applications. We describe the evolution of BAO related to its formal structures, engineering approaches, and content to enable modeling of complex assays and integration with other ontologies and

  10. BIOSAY: a computer program to store and report bioassay data

    International Nuclear Information System (INIS)

    Williams, G.E.; Parlagreco, J.R.

    1978-12-01

    BIOSAY is a computer program designed to manipulate bioassay data. Using BIOSAY, the Dosimetry Group can generate a report suitable for an individual's dosimetry record. A second copy of this report may be mailed to the individual who provided the sample or the area health physicist for review. BIOSAY also contains a data sorting option which allows all the results for particular individuals, or groups of individuals with common attributes, to be separated from the data base. The computer code is written in a conversational tone with aids which make it usable by even casual users of the computer system

  11. TOXICOLOGICAL DRUG SCREENING BY GC-MS VERSUS HPLC-DAD USING A COMMON EFFICIENT EXTRACTION PROCEDURE SCREENING TOXICOLOGIQUE DES MEDICAMENTS PAR HPLC-DAD ET GC-MS: PROTOCOLE D’EXTRACTION UNIQUE

    Directory of Open Access Journals (Sweden)

    SELOUA ELMRABEH

    2015-05-01

    Full Text Available This paper presents a common extraction method for toxicological drug screening by gas chromatography-mass spectrometry (GC-MS and high-performance liquid chromatography with diode-array detection (HPLC-DAD. Liquid-liquid extraction was performed using plasma of 104 samples at the Laboratory of Moroccan Poison Control and Pharmacovigilance Center during a period of 12 months. The results obtained by HPLC-DAD are compared with those determined with GC-MS. 76 cases (73.08 % were found positive for at least by one of these two techniques. HPLC-DAD identified 59.87 % of all positive results, and 10 molecules were identified only by HPLC-DAD. GC/MS identified 40.13 % of all positives, and 4 molecules were identified only by GC/MS. In order to evaluate the performance of this extraction method, an extraction yield was calculated for three classes of drugs. All the analyzed molecules were obtained in satisfactory yields (higher than 50 % except for carbamazepine, amitriptyline and nortriptyline. Overall, the results indicate that the extraction method is well adapted for toxicological drug screening. The use of common extraction simultaneously for the two techniques can reduce workload and costs of screening, while increasing the validity and reliability of the results.

  12. Intake retention functions and their applications to bioassay and the estimation of internal radiation doses

    International Nuclear Information System (INIS)

    Skrable, K.W.; Chabot, G.E.; French, C.S.; La Bone, T.R.

    1988-01-01

    This paper describes a way of obtaining and gives applications of intake retention functions. These functions give the fraction of an intake of radioactive material expected to be present in a specified bioassay compartment at any time after a single acute exposure or after onset of a continuous exposure. The intake retention functions are derived from a multicompartmental model and a recursive catenary kinetics equation that completely describe the metabolism of radioelements from intake to excretion, accounting for the delay in uptake from compartments in the respiratory and gastrointestinal tracts and the recycling of radioelements between systemic compartments. This approach, which treats excretion as the 'last' compartment of all catenary metabolic pathways, avoids the use of convolution integrals and provides algebraic solutions that can be programmed on hand held calculators or personal computers. The estimation of intakes and internal radiation doses and the use of intake retention functions in the design of bioassay programs are discussed along with several examples

  13. The activity of the pyrrole insecticide chlorfenapyr in mosquito bioassay: towards a more rational testing and screening of non-neurotoxic insecticides for malaria vector control.

    Science.gov (United States)

    Oxborough, Richard M; N'Guessan, Raphael; Jones, Rebecca; Kitau, Jovin; Ngufor, Corine; Malone, David; Mosha, Franklin W; Rowland, Mark W

    2015-03-24

    The rapid selection of pyrethroid resistance throughout sub-Saharan Africa is a serious threat to malaria vector control. Chlorfenapyr is a pyrrole insecticide which shows no cross resistance to insecticide classes normally used for vector control and is effective on mosquito nets under experimental hut conditions. Unlike neurotoxic insecticides, chlorfenapyr owes its toxicity to disruption of metabolic pathways in mitochondria that enable cellular respiration. A series of experiments explored whether standard World Health Organization (WHO) guidelines for evaluation of long-lasting insecticidal nets, developed through testing of pyrethroid insecticides, are suitable for evaluation of non-neurotoxic insecticides. The efficacy of WHO recommended cone, cylinder and tunnel tests was compared for pyrethroids and chlorfenapyr. To establish bioassay exposure times predictive of insecticide-treated net (ITN) efficacy in experimental hut trials, standard three-minute bioassays of pyrethroid and chlorfenapyr ITNs were compared with longer exposures. Mosquito behaviour and response to chlorfenapyr ITN in bioassays conducted at night were compared to day and across a range of temperatures representative of highland and lowland transmission. Standard three-minute bioassay of chlorfenapyr produced extremely low levels of mortality compared to pyrethroids. Thirty-minute day-time bioassay produced mortality closer to hut efficacy of chlorfenapyr ITN but still fell short of the WHO threshold. Overnight tunnel test with chlorfenapyr produced 100% mortality and exceeded the WHO threshold of 80%. The endogenous circadian activity rhythm of anophelines results in inactivity by day and raised metabolism and flight activity by night. A model which explains improved toxicity of chlorfenapyr ITN when tested at night, and during the day at higher ambient temperature, is that activation of chlorfenapyr and disruption of respiratory pathways is enhanced when the insect is more metabolically

  14. Principles of Developing Multi-Pesticide Methods Based on HPLC Determination

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    Principles for the development of multi-pesticide methods based on HPLC determination are outlined. Flow charts and block diagrams give guidance on how to proceed stepwise in the set-up of respective analytical methods. Detailed information is provided on what to take into consideration for setting up a pesticide formulation analysis method. HPLC variables like the types of column, solvents and their strength, pH value, eluent modifiers, column temperature, etc, and the influence on the separation and resolution of chromatographic peaks are discussed as well as the necessity and benefits of internal standardization. Examples of system suitability testing experiments are given for illustration. (author)

  15. Combined HPLC-CUPRAC (cupric ion reducing antioxidant capacity) assay of parsley, celery leaves, and nettle.

    Science.gov (United States)

    Yildiz, Leyla; Başkan, Kevser Sözgen; Tütem, Esma; Apak, Reşat

    2008-10-19

    This study aims to identify the essential antioxidant compounds present in parsley (Petroselinum sativum) and celery (Apium graveolens) leaves belonging to the Umbelliferae (Apiaceae) family, and in stinging nettle (Urtica dioica) belonging to Urticaceae family, to measure the total antioxidant capacity (TAC) of these compounds with CUPRAC (cupric ion reducing antioxidant capacity) and ABTS spectrophotometric methods, and to correlate the TAC with high performance liquid chromatography (HPLC) findings. The CUPRAC spectrophotometric method of TAC assay using copper(II)-neocuproine (2,9-dimethyl-1,10-phenanthroline) as the chromogenic oxidant was developed in our laboratories. The individual antioxidant constituents of plant extracts were identified and quantified by HPLC on a C18 column using a modified mobile phase of gradient elution comprised of MeOH-0.2% o-phosphoric acid and UV detection for polyphenols at 280 nm. The TAC values of HPLC-quantified antioxidant constituents were found, and compared for the first time with those found by CUPRAC. The TAC of HPLC-quantified compounds accounted for a relatively high percentage of the observed CUPRAC capacities of plant extracts, namely 81% of nettle, 60-77% of parsley (in different hydrolyzates of extract and solid sample), and 41-57% of celery leaves (in different hydrolyzates). The CUPRAC total capacities of the 70% MeOH extracts of studied plants (in the units of mmol trolox g(-1)plant) were in the order: celery leaves>nettle>parsley. The TAC calculated with the aid of HPLC-spectrophotometry did not compensate for 100% of the CUPRAC total capacities, because all flavonoid glycosides subjected to hydrolysis were either not detectable with HPLC, or not converted to the corresponding aglycons (i.e., easily detectable and quantifiable with HPLC) during the hydrolysis step.

  16. Evidence for paralytic shellfish poisons in the freshwater cyanobacterium Lyngbya wollei (Farlow ex Gomont) comb. nov.

    Science.gov (United States)

    Carmichael, W W; Evans, W R; Yin, Q Q; Bell, P; Moczydlowski, E

    1997-08-01

    Lyngbya wollei (Farlow ex Gomont) comb. nov., a perennial mat-forming filamentous cyanobacterium prevalent in lakes and reservoirs of the southeastern United States, was found to produce a potent, acutely lethal neurotoxin when tested in the mouse bioassay. Signs of poisoning were similar to those of paralytic shellfish poisoning. As part of the Tennessee Valley Authority master plan for Guntersville Reservoir, the mat-forming filamentous cyanobacterium L. wollei, a species that had recently invaded from other areas of the southern United States, was studied to determine if it could produce any of the known cyanotoxins. Of the 91 field samples collected at 10 locations at Guntersville Reservoir, Ala., on the Tennessee River, over a 3-year period, 72.5% were toxic. The minimum 100% lethal doses of the toxic samples ranged from 150 to 1,500 mg kg of lyophilized L. wollei cells-1, with the majority of samples being toxic at 500 mg kg-1. Samples bioassayed for paralytic shellfish toxins by the Association of Official Analytical Chemists method exhibited saxitoxin equivalents ranging from 0 to 58 micrograms g (dry weight)-1. Characteristics of the neurotoxic compound(s), such as the lack of adsorption by C18 solid-phase extraction columns, the short retention times on C18 high-performance liquid chromatography (HPLC) columns, the interaction of the neurotoxins with saxiphilin (a soluble saxitoxin-binding protein), and external blockage of voltage-sensitive sodium channels, led to our discovery that this neurotoxin(s) is related to the saxitoxins, the compounds responsible for paralytic shellfish poisonings. The major saxitoxin compounds thus far identified by comparison of HPLC fluorescence retention times are decarbamoyl gonyautoxins 2 and 3. There was no evidence of paralytic shellfish poison C toxins being produced by L. wollei. Fifty field samples were placed in unialgal culture and grown under defined culture conditions. Toxicity and signs of poisoning for these

  17. Neotropical electric fishes (Gymnotiformes as model organisms for bioassays

    Directory of Open Access Journals (Sweden)

    Milena Ferreira

    2015-04-01

    Full Text Available Electric fishes (Gymnotiformes inhabit Central and South America and form a relatively large group with more than 200 species. Besides a taxonomic challenge due to their still unresolved systematic, wide distribution and the variety of habitats they occupy, these fishes have been intensively studied due to their peculiar use of bioelectricity for electrolocation and communication. Conventional analysis of cells, tissues and organs have been complemented with the studies on the electric organ discharges of these fishes. This review compiles the results of 13 bioassays developed during the last 50 years, which used the quickness, low costs and functionality of the bioelectric data collection of Gymnotiformes to evaluate the effects of environmental contaminants and neuroactive drugs.

  18. Bioassay techniques for {sup 55}Fe in urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Cregan, S P; Leon, J W; Linauskas, S H

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for {sup 55}Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH){sub 3}. precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs.

  19. Validated RP-HPLC Method for Quantification of Phenolic ...

    African Journals Online (AJOL)

    Purpose: To evaluate the total phenolic content and antioxidant potential of the methanol extracts of aerial parts and roots of Thymus sipyleus Boiss and also to determine some phenolic compounds using a newly developed and validated reversed phase high performance liquid chromatography (RP-HPLC) method.

  20. Addressing the recovery of feeding rates in post-exposure feeding bioassays: Cyathura carinata as a case study

    Energy Technology Data Exchange (ETDEWEB)

    Pais-Costa, Antonia Juliana [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal); Acevedo, Pelayo [SaBio IREC, Instituto de Investigación en Recursos Cinegéticos (UCLM-CSIC-JCCM), Ciudad Real 13005 (Spain); Marques, João Carlos [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal); Martinez-Haro, Mónica, E-mail: monica.martinezharo@gmail.com [IMAR—Institute of Marine Research, MARE—Marine and Environmental Sciences Centre, Faculty of Sciences and Technology, University of Coimbra, 3004-517 Coimbra (Portugal)

    2015-02-15

    Post-exposure bioassays are used in environmental assessment as a cost-effective tool, but the effects of organism's recovery after exposure to pollutant has not yet been addressed in detail. The recoveries of post-exposure feeding rates after being exposed to two sublethal concentrations of cadmium during two different exposure periods (48 h and 96 h) were evaluated under laboratory conditions using the estuarine isopod Cyathura carinata. Results showed that feeding depression was a stable endpoint up to 24 h after cadmium exposure, which is useful for ecotoxicological bioassays. - Highlights: • We studied recovery of post-exposure feeding rates 48–96 h after cadmium exposure. • The assay is based on the isopod Cyathura carinata. • Post-exposure feeding inhibition is a stable sublethal endpoint.

  1. Determination of sulfonamides and trimethoprim using high temperature HPLC with simultaneous temperature and solvent gradient.

    Science.gov (United States)

    Giegold, Sascha; Teutenberg, Thorsten; Tuerk, Jochen; Kiffmeyer, Thekla; Wenclawiak, Bernd

    2008-10-01

    A fast HPLC method for the analysis of eight selected sulfonamides (SA) and trimethoprim has been developed with the use of high temperature HPLC. The separation could be achieved in less than 1.5 min on a 50 mm sub 2 microm column with simultaneous solvent and temperature gradient programming. Due to the lower viscosity of the mobile phase and the increased mass transfer at higher temperatures, the separation could be performed on a conventional HPLC system obtaining peak widths at half height between 0.6 and 1.3 s.

  2. In vivo genotoxicity of furan in F344 rats at cancer bioassay doses

    International Nuclear Information System (INIS)

    Ding, Wei; Petibone, Dayton M.; Latendresse, John R.; Pearce, Mason G.; Muskhelishvili, Levan; White, Gene A.; Chang, Ching-Wei; Mittelstaedt, Roberta A.; Shaddock, Joseph G.; McDaniel, Lea P.; Doerge, Daniel R.; Morris, Suzanne M.; Bishop, Michelle E.; Manjanatha, Mugimane G.; Aidoo, Anane; Heflich, Robert H.

    2012-01-01

    Furan, a potent rodent liver carcinogen, is found in many cooked food items and thus represents a human cancer risk. Mechanisms for furan carcinogenicity were investigated in male F344 rats using the in vivo Comet and micronucleus assays, combined with analysis of histopathological and gene expression changes. In addition, formamidopyrimidine DNA glycosylase (Fpg) and endonuclease III (EndoIII)-sensitive DNA damage was monitored as a measure of oxidative DNA damage. Rats were treated by gavage on four consecutive days with 2, 4, and 8 mg/kg bw furan, doses that were tumorigenic in 2-year cancer bioassays, and with two higher doses, 12 and 16 mg/kg. Rats were killed 3 h after the last dose, a time established as producing maximum levels of DNA damage in livers of furan-treated rats. Liver Comet assays indicated that both DNA strand breaks and oxidized purines and pyrimidines increased in a near-linear dose-responsive fashion, with statistically significant increases detected at cancer bioassay doses. No DNA damage was detected in bone marrow, a non-target tissue for cancer, and peripheral blood micronucleus assays were negative. Histopathological evaluation of liver from furan-exposed animals produced evidence of inflammation, single-cell necrosis, apoptosis, and cell proliferation. In addition, genes related to apoptosis, cell-cycle checkpoints, and DNA-repair were expressed at a slightly lower level in the furan-treated livers. Although a mixed mode of action involving direct DNA binding cannot be ruled out, the data suggest that furan induces cancer in rat livers mainly through a secondary genotoxic mechanism involving oxidative stress, accompanied by inflammation, cell proliferation, and toxicity. -- Highlights: ► Furan is a potent rodent liver carcinogen and represents a human cancer risk. ► Furan induces DNA damage in rat liver at cancer bioassay doses. ► Furan induces oxidative stress, inflammation and cell proliferation in rat liver. ► Expression of

  3. Human sperm bioassay has potential in evaluating the quality of cumulus-oocyte complexes.

    Science.gov (United States)

    Hossain, A M; Rizk, B; Huff, C; Helvacioglu, A; Thorneycroft, I H

    1996-01-01

    Human sperm bioassay is routinely used as a quality control check for the culture media. This is one of the three bioassays chosen by the College of American Pathologists (CAP) for interlaboratory proficiency testing to assess the standards of in vitro fertilization (IVF) and andrology laboratories. This study utilized sperm bioassay to assess the quality of cumulus-oocyte complexes (COCs) retrieved in IVF procedures COCs, harvested from the female partner of IVF couples, undergoing identical ovarian stimulation protocols, were individually inseminated with the sperm of the corresponding male partner. Sperm motility in sperm-COC cocultures were compared. Cocultures were established by inseminating the 103 COCs, retrieved from 18 IVF couples with 1 x 10(5) to 2 x 10(5) sperm of the corresponding male partners of the couples. In all 18 cases, the sperm were prepared identically using the Percoll wash method. The cocultures were maintained for 48 h but the oocytes were removed immediately after the fertilization check (approximately 16 h). The motility of sperm in the cocultures and in the insemination stocks were noted and 17 of 18 sperm stocks used for insemination had similar high preinsemination motility (90.2 +/- 5.0%). At 48 h the sperm motility had significantly decreased in the cocultures compared to the insemination stocks; 52.7 +/- 19.9% versus 67.2 +/- 10.4%. There was no difference in the motility among the small, medium, and large COCs (56.4 +/- 24.6%, 52.5 +/- 17.9%, and 50.8 +/- 20.9%, respectively). In 45% of IVF cases, the motility in cocultures varied widely, falling below as well as above that of their corresponding insemination stocks. Furthermore, the sperm motility varied among the cocultures in both pregnant and nonpregnant patients but the extent of variation appears to be greater in the latter. The inter-COC coculture sperm motility variation most likely is due to the differences in the quality of cumulus-oocyte complexes.

  4. Sensitivity and Specificity of Bioassay of Estrogenicity on Mammary Gland and Uterus of Female Mice

    Czech Academy of Sciences Publication Activity Database

    Škarda, Josef

    2002-01-01

    Roč. 51, - (2002), s. 407-412 ISSN 0862-8408 R&D Projects: GA ČR GA523/99/0843; GA AV ČR KSK5020115 Institutional research plan: CEZ:AV0Z5045916 Keywords : Bioassay * Estrogenicity * Mammary gland Subject RIV: ED - Physiology Impact factor: 0.984, year: 2002

  5. Determination of Biochemical Oxygen Demand of Area Waters: A Bioassay Procedure for Environmental Monitoring

    Science.gov (United States)

    Riehl, Matthew

    2012-01-01

    A graphical method for determining the 5-day biochemical oxygen demand (BOD5) for a body of water is described. In this bioassay, students collect a sample of water from a designated site, transport it to the laboratory, and evaluate the amount of oxygen consumed by naturally occurring bacteria during a 5-day incubation period. An accuracy check,…

  6. Quality control of radiopharmaceuticals with HPLC using aqueous size exclusion spherogel column

    International Nuclear Information System (INIS)

    Vallabhajosula, S.; Goldsmith, S.J.; Lipszyc, H.

    1982-01-01

    The application of HPLC for the analysis and quality control of 99 Tc-radiopharmaceuticals, using a weakly basic anion exchange column, has been reported. This HPLC method for the separation of the components is based on molecular size. 99 Tc-MDP, 99 Tc-HDP and 99 Tc-DTPA were analysed and UV absorption studies carried out on the components. Components of the 99 Tc-MDP separation were injected into rabbits and renal excretion and serial images studied. (U.K.)

  7. HPLC Analysis of nine corticosteroids in “natural creams” for atopic eczema

    OpenAIRE

    Ameti, Agim; Poposka, Zaklina; Memeti, Shaban; Shishovska, Maja; Mustafa, Zana; Starkoska, Katerina; Arsova-Sarafinovska, Zorica

    2013-01-01

    Purpose: The aim of the study was to determine whether “natural creams” sold for treatment of childhood atopic eczema illegally contain corticosteroids with a newly developed rapid and simple HPLC analysis with UV detection. Material and Methods: HPLC analysis was performed using a Schimadzu LC-2010 chromatographic system (Schimadzu, Kyoto, Japan) consisting of a LC-20AT Prominence liquid chromatography pump with DGU-20A5 Prominence degasser, a SPD-M20A Prominence Diode Array Detector, and...

  8. DOSEXPRT: A bioassay dosimetry code for Martin Marietta Energy Systems, Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Ward, R.C.; Eckerman, K.F.

    1992-04-01

    The bioassay code DOSEXPRT was developed for Martin Marietta Energy Systems, Inc., to provide compliance with Department of Energy (DOE) Order 5480, Chapter 11. DOSEXPRT computes the intake of a radionuclide in any year (considering both acute and chronic intakes) from in vivo measurements of the retained activity and/or measurements of the activity in excreta. The committed effective and organ doses for the intake are computed as well as the effective and organ doses expected to be received in each calendar year out to 50 years beyond the year of intake. The bioassay records used as input for DOSEXPRT are extracted from the Martin Marietta Energy Systems Occupational Health Information System (OHIS). DOSEXPRT implements a set of algorithms with parameters governing the translocation, retention, and excretion of the nuclide contained in data files specific to the nuclide. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent for the intakes in the year. Annual organ and effective doses are computed using additional dose-rate files that contain data on the dose rate at various times following a unit intake. If measurements are presented for more than one assay for a given nuclide, DOSEXPRT estimates the intake by applying weights assigned in the nuclide file for each assay. DOSEXPRT is accessed off the OHIS MENU No. 4 and designed to be run as a batch processor, but can also be run interactively for testing purposes.

  9. DOSEXPRT: A bioassay dosimetry code for Martin Marietta Energy Systems, Inc

    Energy Technology Data Exchange (ETDEWEB)

    Ward, R.C.; Eckerman, K.F.

    1992-04-01

    The bioassay code DOSEXPRT was developed for Martin Marietta Energy Systems, Inc., to provide compliance with Department of Energy (DOE) Order 5480, Chapter 11. DOSEXPRT computes the intake of a radionuclide in any year (considering both acute and chronic intakes) from in vivo measurements of the retained activity and/or measurements of the activity in excreta. The committed effective and organ doses for the intake are computed as well as the effective and organ doses expected to be received in each calendar year out to 50 years beyond the year of intake. The bioassay records used as input for DOSEXPRT are extracted from the Martin Marietta Energy Systems Occupational Health Information System (OHIS). DOSEXPRT implements a set of algorithms with parameters governing the translocation, retention, and excretion of the nuclide contained in data files specific to the nuclide. These files also contain dose-per-unit-intake coefficients used to compute the committed dose equivalent for the intakes in the year. Annual organ and effective doses are computed using additional dose-rate files that contain data on the dose rate at various times following a unit intake. If measurements are presented for more than one assay for a given nuclide, DOSEXPRT estimates the intake by applying weights assigned in the nuclide file for each assay. DOSEXPRT is accessed off the OHIS MENU No. 4 and designed to be run as a batch processor, but can also be run interactively for testing purposes.

  10. [Studies on fingerprinting of Flos Buddleja by RP-HPLC].

    Science.gov (United States)

    Han, Peng; Cui, Ya-jun; Guo, Hong-zhu; Guo, De-an

    2004-10-01

    To establish fingerprinting of Flos Buddleja by using RP-HPLC for the quality control. The HPLC condition was as follows: Inertsil ODS-3 C18 analytical column (4.6 mm x 250 mm, 5 microm), gredient eluation with MeCN (0.1% TFA)-H2O (0.1%TFA), flow rate 1.0 mL x min(-1), detection wavelength 254 nm. 10 commercial samples were analyzed to establish a fingerprinting. Among the obtained fingerprinting, most of the detected peaks were separated effectively. The accuracy, repeatability and stability of this method were satisfied. The RSDs of relative retention time and area of aimed peaks which existed in all samples wereless than 5%. Theresults were in accordance with the request of fingerprinting. The established fingerprinting can be used for the quality control of Flos Buddleja.

  11. Efficacy of enrofloxacin in a mouse model of sepsis.

    Science.gov (United States)

    Slate, Andrea R; Bandyopadhyay, Sheila; Francis, Kevin P; Papich, Mark G; Karolewski, Brian; Hod, Eldad A; Prestia, Kevin A

    2014-07-01

    We examined the efficacy of enrofloxacin administered by 2 different routes in a mouse model of sepsis. Male CD1 mice were infected with a bioluminescent strain of enteropathogenic Escherichia coli and treated with enrofloxacin either by injection or in drinking water. Peak serum levels were evaluated by using HPLC. Mice were monitored for signs of clinical disease, and infections were monitored by using bioluminescence imaging. Serum levels of enrofloxacin and the active metabolite ciprofloxacin were greater in the group treated by injection than in controls or the groups treated by administration in drinking water. Survival of the group treated with enrofloxacin injection was greater than that of controls and groups treated with enrofloxacin in the drinking water. Bioluminescence in the group treated with enrofloxacin injection was less than that in the groups treated with oral administration at 12 h and in the groups treated orally and the control group at 16 h. According to these findings, we recommend the use of injectable enrofloxacin at 5 mg/kg SC for mice with systemic infections.

  12. A preliminary evaluation of the toxic equivalence factor (TEF) for 2,3,4,7,8-PCDF (4-PCDF) using data from the recent NTP dioxin bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Budinsky, R.; Landenberger, B.; Fontaine, D. [The Dow Chemical Company (United States); Starr, T.B. [TBS Associates, Raleigh, NC (United States); Paustenbach, D. [ChemRisk (United States)

    2004-09-15

    PCDD/PCDF toxic equivalency factors (TEFs) are being routinely applied now in human cancer risk assessments for dioxin-like compounds despite the fact that until very recently only two congeners (1,2,3,6,7,8- and 1,2,3,7,8,9-hexachlorodibenzo-p-dioxin) other than 2,3,7,8-TCDD had been evaluated for carcinogenicity in a standard cancer bioassay. However, in December 2003, draft reports from the National Toxicology Program (NTP) cancer bioassays were made available for 2,3,7,8-TCDD, 4-PCDF, PCB 126, and a (presumably) equipotent mixture of these three compounds. These data provide important new information for evaluating the accuracy of TEFs in predicting the potential human cancer hazard for 4-PCDF and PCB126 alone and in combination with TCDD. We present herein results from a series of simple statistical tests demonstrating that the current TEF of 0.5 for 4-PCDF, when combined appropriately with the new TCDD bioassay data, fails to predict accurately the results from the new 4-PCDF bioassay.

  13. Competitive Nitration of Benzene-Fluorobenzene and Benzene-Toluene Mixtures: Orientation and Reactivity Studies Using HPLC

    Science.gov (United States)

    Blankespoor, Ronald L.; Hogendoorn, Stephanie; Pearson, Andrea

    2007-01-01

    The reactivity and orientation effects of a substituent are analyzed by using HPLC to determine the competitive nitration of the benzene-toluene and benzene-fluorobenzene mixtures. The results have shown that HPLC is an excellent instrumental method to use in analyzing these mixtures.

  14. New in vitro reporter gene bioassays for screening of hormonal active compounds in the environment

    Czech Academy of Sciences Publication Activity Database

    Svobodová, Kateřina; Cajthaml, Tomáš

    2010-01-01

    Roč. 88, č. 4 (2010), s. 839-847 ISSN 0175-7598 R&D Projects: GA ČR GAP503/10/0408 Institutional research plan: CEZ:AV0Z50200510 Keywords : endocrine disruptors * in vitro bioassays * reporter gene assays Subject RIV: EE - Microbiology, Virology Impact factor: 3.280, year: 2010

  15. Gradient Scouting in Reversed-Phase HPLC Revisited

    Science.gov (United States)

    Alcazar, A.; Jurado, J. M.; Gonzalez, A. G.

    2011-01-01

    Gradient scouting is the best way to decide the most suitable elution mode in reversed-phase high-performance liquid chromatography (RP-HPLC). A simple rule for this decision involves the evaluation of the ratio [delta]t/t[subscript G] (where [delta]t is the difference in the retention time between the last and the first peak and t[subscript G] is…

  16. Larval development ratio test with the calanoid copepod Acartia tonsa as a new bioassay to assess marine sediment quality.

    Science.gov (United States)

    Buttino, Isabella; Vitiello, Valentina; Macchia, Simona; Scuderi, Alice; Pellegrini, David

    2018-03-01

    The copepod Acartia tonsa was used as a model species to assess marine sediment quality. Acute and chronic bioassays, such as larval development ratio (LDR) and different end-points were evaluated. As a pelagic species, A. tonsa is mainly exposed to water-soluble toxicants and bioassays are commonly performed in seawater. However, an interaction among A. tonsa eggs and the first larval stages with marine sediments might occur in shallow water environments. Here we tested two different LDR protocols by incubating A. tonsa eggs in elutriates and sediments coming from two areas located in Tuscany Region (Central Italy): Livorno harbour and Viareggio coast. The end-points analyzed were larval mortality (LM) and development inhibition (DI) expressed as the percentage of copepods that completed the metamorphosis from nauplius to copepodite. Aims of this study were: i) to verify the suitability of A. tonsa copepod for the bioassay with sediment and ii) to compare the sensitivity of A. tonsa exposed to different matrices, such as water and sediment. A preliminary acute test was also performed. Acute tests showed the highest toxicity of Livorno's samples (two out of three) compared to Viareggio samples, for which no effect was observed. On the contrary, LDR tests with sediments and elutriates revealed some toxic effects also for Viareggio's samples. Results were discussed with regards to the chemical characterization of the samples. Our results indicated that different end-points were affected in A. tonsa, depending on the matrices to which the copepods were exposed and on the test used. Bioassays with elutriates and sediments are suggested and LDR test could help decision-makers to identify a more appropriate management of dredging materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Comparison of UHPLC and HPLC in Benzodiazepines Analysis of Postmortem Samples

    Science.gov (United States)

    Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein

    2015-01-01

    Abstract The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case–control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis. PMID:25860209

  18. Development and Validation of a Stability-Indicating RP-HPLC ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating RP-HPLC Method for ... of Paracetamol, Tramadol HCl and Domperidone in a Combined Dosage Form. ... testing, as well as for quality control of the combined drugs in pharmaceutical ...

  19. Potential effects of the herbicide Diuron on mammary and urinary bladder two-stage carcinogenesis in a female Swiss mouse model.

    Science.gov (United States)

    de Moura, Nelci Antunes; Grassi, Tony Fernando; Rodrigues, Maria Aparecida Marchesan; Barbisan, Luís Fernando

    2010-02-01

    The potential promoting effect of Diuron was investigated in a mouse model of mammary and urinary bladder carcinogenesis induced by 7,12-dimethylbenz(a)anthracene (DMBA) and N-butyl-N-(4-hydroxybutyl)nitrosamine (BBN). Four-week old female Swiss mice were allocated to five groups: Groups G1-G3 received DMBA (5 x 1.5 mg/mouse) and BBN (8 x 7.5 mg/mouse) and G4 and G5 groups received only vehicles during the first 6 weeks. At week 7, G1 and G5 groups received basal diet and G2, G3 and G4 groups were fed a diet containing Diuron at 1,250, 2,500 and 2,500 ppm, respectively, during 13 weeks. At week 20, the animals were euthanized and the gross tumors were registered. Mammary glands and urinary bladder were processed for histopathological analysis. Samples from non-tumor areas were evaluated for cell proliferation by 5-bromodeoxyuridine labeling index (BrdU-LI%) and apoptosis. Dietary treatment with Diuron at 1,250 and 2,500 ppm significantly increased BrdU-LI% (P Diuron 2,500 ppm (G3). In contrast, in the mammary gland, Diuron feeding for 13 weeks did not significantly alter cell proliferation and apoptosis indexes or the incidence of hyperplastic lesions or neoplasms in the DMBA/BBN-initiated groups. These findings suggest that Diuron is a promoting agent to the urinary bladder but not to the mammary gland in female Swiss mice submitted to a medium-term two-stage carcinogenesis bioassay.

  20. Arsenic-containing fatty acids and hydrocarbons in marine oils - Determination using reversed-phase HPLC-ICP-MS and HPLC-qTOF-MS

    DEFF Research Database (Denmark)

    Sele, Veronika; Sloth, Jens Jørgen; Holmelid, Bjarte

    2014-01-01

    ; dimethylarsinate (DMA), triphenylarsinoxide (Ph3AsO) and a synthesized arsenic-containing hydrocarbon (AsHC) (dimethylarsinoyl nonadecane; C21H43AsO). The observed variation in signal intensity for arsenic during the gradient elution profile in reversed-phase HPLC was compensated for by determining the time...

  1. Cluster analysis of historical and modern hard red spring wheat cultivars based on parentage and HPLC analysis of gluten forming proteins

    Science.gov (United States)

    In this study, 30 hard red spring (HRS) wheat cultivars released between 1910 and 2013 were analyzed to determine how they cluster in terms of parentage and protein data, analyzed by reverse-phase HPLC (RP-HPLC) of gliadins, and size-exclusion HPLC (SE-HPLC) of unreduced proteins. Dwarfing genes in...

  2. [Study on HPLC-FPS of raw and processed fructus polygoni orientalis].

    Science.gov (United States)

    Zhai, Yanjun; Zhao, Min; Zhang, Hui; Chu, Zhengyun; Kang, Tingguo

    2010-03-01

    To establish the HPLC fingerprint method of Fructus Polygoni Orientalis before and after processed by choosing taxifolin as reference to compare the changes of chemical composition. HPLC method was emplyed with a gradient elution phase in a flow rate of 1 mL x min(-1) and the detection wavelength of 270 nm. Twenty marker peaks were marked out in the raw samples and 33 marker peaks in the processed product. Methodology met was consistent with the requirement, similarity was exceeded 0.9. This method is stationary, precise and feasible, which provide references of quality control for Fructus Polygoni Orientalis.

  3. Bioassay-Guided Isolated Compounds from Morinda officinalis Inhibit Alzheimer’s Disease Pathologies

    Directory of Open Access Journals (Sweden)

    Yoon Kyoung Lee

    2017-09-01

    Full Text Available Due to the side effects of synthetic drugs, the therapeutic potential of natural products for Alzheimer’s disease (AD has gained interest. Morinda officinalis has demonstrated inhibitory effects on geriatric diseases, such as bone loss and osteoporosis. However, although AD is a geriatric disease, M. officinalis has not been evaluated in an AD bioassay. Therefore, M. officinalis extracts and fractions were tested for AD-related activity, including inhibition of acetylcholinesterase (AChE, butyrylcholinesterase (BChE, β-site amyloid precursor protein cleaving enzyme 1 (BACE1, and advanced glycation end-product (AGE formation. A bioassay-guided approach led to isolation of 10 active compounds, eight anthraquinones (1–8, one coumarin (9, and one phytosterol (10, from n-hexane and ethyl acetate fractions of M. officinalis. The five anthraquinones (4–8 were stronger inhibitors of AChE than were other compounds. Compounds 3 and 9 were good inhibitors of BChE, and compounds 3 and 8 were good inhibitors of BACE1. Compounds 1–5 and 7–9 were more active than the positive control in inhibiting AGE formation. In addition, we first suggested a structure-activity relationship by which anthraquinones inhibit AChE and BACE1. Our findings demonstrate the preventive and therapeutic efficacy of M. officinalis for AD and its potential use as a natural alternative medicine.

  4. Validated Reverse Phase HPLC Method for the Determination of Impurities in Etoricoxib

    Directory of Open Access Journals (Sweden)

    S. Venugopal

    2011-01-01

    Full Text Available This paper describes the development of reverse phase HPLC method for etoricoxib in the presence of impurities and degradation products generated from the forced degradation studies. The drug substance was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation of etoricoxib was observed under base and oxidation environment. The drug was found stable in other stress conditions studied. Successful separation of the drug from the process related impurities and degradation products were achieved on zorbax SB CN (250 x 4.6 mm 5 μm particle size column using reverse phase HPLC method. The isocratic method employed with a mixture of buffer and acetonitrile in a ratio of 60:40 respectively. Disodium hydrogen orthophosphate (0.02 M is used as buffer and pH adjusted to 7.20 with 1 N sodium hydroxide solution. The HPLC method was developed and validated with respect to linearity, accuracy, precision, specificity and ruggedness.

  5. Olfactoryresponse of the predatory mite Typhlodromus pyri (Acari: Phytoseiidae) to methyl salicylate in laboratory bioassays

    Science.gov (United States)

    The response of Typhlodromus pyri, a key predator of grapevine rust mite (Calepitrimerus vitis), to MeSA was tested using a Y-tube olfactometer in laboratory bioassays. Six doses ranging from 200 to 0.002 µg of diluted MeSA were tested. Significantly higher proportions of T. pyri preferred MeSA at ...

  6. Effect-based trigger values for in vitro and in vivo bioassays performed on surface water extracts supporting the environmental quality standards (EQS) of the European Water Framework Directive

    NARCIS (Netherlands)

    Escher, Beate I.; Aїt-Aїssa, Selim; Behnisch, Peter A.; Brack, Werner; Brion, François; Brouwer, Abraham; Buchinger, Sebastian; Crawford, Sarah E.; Du Pasquier, David; Hamers, Timo; Hettwer, Karina; Hilscherová, Klára; Hollert, Henner; Kase, Robert; Kienle, Cornelia; Tindall, Andrew J.; Tuerk, Jochen; van der Oost, Ron; Vermeirssen, Etienne; Neale, Peta A.

    Effect-based methods including cell-based bioassays, reporter gene assays and whole-organism assays have been applied for decades in water quality monitoring and testing of enriched solid-phase extracts. There is no common EU-wide agreement on what level of bioassay response in water extracts is

  7. Feasibility studies to assess the use of 236Pu as a radiochemical yield monitor in bioassay samples

    International Nuclear Information System (INIS)

    Sawant, P.D.; Kalsi, P.C.

    2007-01-01

    Various plutonium compounds are handled in nuclear facilities of BARC. Hence, there is a possibility of occupational workers getting exposed to Pu. In vitro bioassay monitoring in which Pu is separated by chemical procedures from excreta samples and estimated by alpha-spectrometry, is the method of choice for the evaluation of internal dose to the occupational workers handling Pu. However, this method requires a suitable Pu tracer for reducing the uncertainties due to chemical yield in the separation, electro-deposition and counting efficiency. 242 Pu is commonly used as a tracer but due to its non-availability, efforts were made earlier to indigenously synthesis 236 Pu by proton irradiation of 237 Np in BARC-TIFR pelletron facility. The present study, reports the feasibility of using 236 Pu as a radiochemical yield monitor (tracer) in bioassay samples. (author)

  8. Monitoring resistance to Bacillus thuringiensis subsp. israelensis in the field by performing bioassays with each Cry toxin separately

    Directory of Open Access Journals (Sweden)

    Guillaume Tetreau

    2013-11-01

    Full Text Available Bacillus thuringiensis subsp. israelensis (Bti is increasingly used worldwide for mosquito control and is the only larvicide used in the French Rhône-Alpes region since decades. The artificial selection of mosquitoes with field-persistent Bti collected in breeding sites from this region led to a moderate level of resistance to Bti, but to relatively high levels of resistance to individual Bti Cry toxins. Based on this observation, we developed a bioassay procedure using each Bti Cry toxin separately to detect cryptic Bti-resistance evolving in field mosquito populations. Although no resistance to Bti was detected in none of the three mosquito species tested (Aedes rusticus, Aedes sticticus and Aedes vexans, an increased tolerance to Cry4Aa (3.5-fold and Cry11Aa toxins (8-fold was found in one Ae. sticticus population compared to other populations of the same species, suggesting that resistance to Bti may be arising in this population. This study confirms previous works showing a lack of Bti resistance in field mosquito populations treated for decades with this bioinsecticide. It also provides a first panorama of their susceptibility status to individual Bti Cry toxins. In combination with bioassays with Bti, bioassays with separate Cry toxins allow a more sensitive monitoring of Bti-resistance in the field.

  9. Use of plant and earthworm bioassays to evaluate remediation of soil from a site contaminated with polychlorinated biphenyls

    Energy Technology Data Exchange (ETDEWEB)

    Meier, J.R.; Chang, L.W.; Meckes, M.C.; Smith, M.K. [Environmental Protection Agency, Cincinnati, OH (United States); Jacobs, S. [DynCorp, Cincinnati, OH (United States); Torsella, J. [Oak Ridge Inst. of Science and Education, Cincinnati, OH (United States)

    1997-05-01

    Soil from a site heavily contaminated with polychlorinated biphenyls (PCBs) was treated with a pilot-scale, solvent extraction technology. Bioassays in earthworms and plants were used to examine the efficacy of the remediation process for reducing the toxicity of the soil. The earthworm toxicity bioassays were the 14-d survival test and 21-d reproduction test, using Lumbricus terrestris and Eisenia fetida andrei. The plant bioassays included phytotoxicity tests for seed germination and root elongation in lettuce and oats, and a genotoxicity test (anaphase aberrations) in Allium cepa (common onion). Although the PCB content of the soil was reduced by 99% (below the remediation goal), toxicity to earthworm reproduction remained essentially unchanged following remediation. Furthermore, phytotoxicity and genotoxicity were higher for the remediated soil compared to the untreated soil. The toxicity remaining after treatment appeared to be due to residual solvent introduced during the remediation process, and/or to heavy metals or other inorganic contaminants not removed by the treatment. Mixture studies involving isopropanol and known toxicants indicated possible synergistic effects of the extraction solvent and soil contaminants. The toxicity in plants was essentially eliminated by a postremediation, water-rinsing step. These results demonstrate a need for including toxicity measurements in the evaluation of technologies used in hazardous waste site remediations, and illustrate the potential value of such measurements for making modifications to remediation processes.

  10. Fluconazole Pharmacokinetics in Galleria mellonella Larvae and Performance Evaluation of a Bioassay Compared to Liquid Chromatography-Tandem Mass Spectrometry for Hemolymph Specimens

    Science.gov (United States)

    Astvad, Karen Marie Thyssen; Meletiadis, Joseph; Whalley, Sarah

    2017-01-01

    ABSTRACT The invertebrate model organism Galleria mellonella can be used to assess the efficacy of treatment of fungal infection. The fluconazole dose best mimicking human exposure during licensed dosing is unknown. We validated a bioassay for fluconazole detection in hemolymph and determined the fluconazole pharmacokinetics and pharmacodynamics in larval hemolymph in order to estimate a humanized dose for future experiments. A bioassay using 4-mm agar wells, 20 μl hemolymph, and the hypersusceptible Candida albicans DSY2621 was established and compared to a validated liquid chromatography-tandem mass spectrometry (LC–MS-MS) method. G. mellonella larvae were injected with fluconazole (5, 10, and 20 mg/kg of larval weight), and hemolymph was harvested for 24 h for pharmacokinetics calculations. The exposure was compared to the human exposure during standard licensed dosing. The bioassay had a linear standard curve between 1 and 20 mg/liter. Accuracy and coefficients of variation (percent) values were below 10%. The Spearman coefficient between assays was 0.94. Fluconazole larval pharmacokinetics followed one-compartment linear kinetics, with the 24-h area under the hemolymph concentration-time curve (AUC24 h) being 93, 173, and 406 mg · h/liter for the three doses compared to 400 mg · h/liter in humans under licensed treatment. In conclusion, a bioassay was validated for fluconazole determination in hemolymph. The pharmacokinetics was linear. An exposure comparable to the human exposure during standard licensed dosing was obtained with 20 mg/kg. PMID:28760893

  11. Activity behavior of a HPLC column including α-chymotrypsin immobilized monosized-porous particles

    International Nuclear Information System (INIS)

    Bilici, Z.; Camli, S.T.; Unsal, E.; Tuncel, A.

    2004-01-01

    In this study, a polymer-based, α-chymotrypsin (CT) immobilized HPLC column was prepared as a potential material for affinity-HPLC and chiral separation applications. Monosized-macroporous particles were synthesized as the support material by a relatively new polymerization protocol, the so-called, 'modified seeded polymerization'. The particles were obtained in the form of styrene-glycidyl methacrylate- divinylbenzene terpolymer approximately 11 μm in size. The particles were treated with aqueous ammonia to have primary amine groups on the porous surface. The amine functionalized particles were reacted by glutaraldehyde and the enzyme, CT, was covalently attached. CT carrying monosized-porous particles were slurry packed into the HPLC column 50 mmx4.6 mm in size. Since the activity behavior of immobilized CT played an important role in the enantiomeric separations performed by similar columns, the enzymatic activity behavior of the column produced by our protocol was determined. For this purpose, HPLC column was used as a packed bed reactor and the enzymatic reaction was continuously followed by measuring the absorbance of the output flow by the UV-detector of HPLC. S-shaped absorbance-time curves were obtained by monitoring the reactor output both in dynamic and steady-state periods. The columns with relatively lower immobilized enzyme content were more sensitive to the changes in the operating conditions and responded with more appreciable substrate conversion changes. The maximum reaction rate of the immobilized enzyme was estimated as approximately 25% of the free one by the mathematical model describing the activity behavior of the column. No significant loss was observed in the activity of the immobilized enzyme during the course of the experiments

  12. Mouse allergen exposure and immunologic responses: IgE-mediated mouse sensitization and mouse specific IgG and IgG4 levels

    NARCIS (Netherlands)

    Matsui, Elizabeth C.; Krop, Esmeralda J. M.; Diette, Gregory B.; Aalberse, Rob C.; Smith, Abigail L.; Eggleston, Peyton A.

    2004-01-01

    Although there is evidence that contact with mice is associated with IgE-mediated mouse sensitization and mouse specific antibody responses, the exposure-response relationships remain unclear. To determine whether IgE-mediated mouse sensitization and mouse specific IgG (mIgG) and mIgG4 levels

  13. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    Science.gov (United States)

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  14. Bioassay of circulating luteinizing hormone in the rhesus monkey: comparison with radioimmunoassay during physiological changes

    International Nuclear Information System (INIS)

    Dufau, M.L.; Hodgen, G.D.; Goodman, A.L.; Catt, K.J.

    1977-01-01

    The concentration of biologically active LH in Rhesus monkey (Macaca mulatta) serum was measured by a highly sensitive bioassay based upon testosterone production by dispersed rat interstitial cells. The sensitivity of the in vitro bioassay was equal to or higher than that of radioimmunoassay, with detection limits of 0.1 mIU of human menopausal gonadotropin (hMG) or 10 ng of a Rhesus pituitary gonadotropin preparation (LER-1909-2). Parallel dose-response curves were obtained for hMG and Rhesus monkey pituitary gonadotropin. The method permits bioassay of LH in 20--100 μl of serum from adult male monkeys, and from female monkeys during the follicular and luteal phases of the menstrual cycle. Bioactive LH concentrations could be assayed in 0.25 to 5 μl of serum from mid-cycle, postmenopausal, and castrated female monkeys. Serum LH was undetectable in two hypophysectomized adult female monkeys and six intact immature animals, and was 13 +- 6 (SD) mIU/ml in adult male monkeys. In adult females, follicular phase LH levels ranged from 17 to 169 mIU/ml, with a mean of 76 +- 52 mIU/ml. The midcycle LH peak was 1738 +- 742 mIU/ml and the luteal phase values ranged from 6-47 mIU/ml, with a mean of 35 +- 5 mIU/ml. Serum LH concentrations ranged from 100 to 900 mIU/ml in two menopausal females, and from 590--1480 mIU/ml in castrated females. Treatment of castrated female monkeys with estrogen plus progesterone produced an initial two-fold rise in sepum LH within 3 days, followed by a gradual decline to one-fourth to one-tenth of the initial levels after 10 days of treatment. Serum LH was suppressed to undetectable levels during the third week, and remained so for the duration of the 60-day treatment period

  15. Expermental Studies of quantitative evaluation using HPLC and safety of Sweet Bee Venom

    OpenAIRE

    Ki Rok Kwon; Ching Seng Chu; Hee Soo Park; Min Ki Kim; Bae Chun Cha; Eun Lee

    2007-01-01

    Objectives : This study was conducted to carry out quantitative evaluation and safety of Sweet Bee Venom. Methods : Content analysis was done using HPLC, measurement of LD50 was conducted intravenous, subcutaneous, and intra-muscular injection to the ICR mice. Results : 1. According to HPLC analysis, removal of the enzymes containing phospholipase A2 was successfully rendered on Sweet Bee Venom. And analyzing melittin content, Sweet Bee Venom contained 12% more melittin than Bee Venom. ...

  16. Bioassay and characterization of soil microorganisms involved in the biodegradation of the fungicide, metalaxyl

    International Nuclear Information System (INIS)

    Bailey, A.M.

    1985-01-01

    A sensitive bioassay was developed to detect low concentrations of metalaxyl in soils. The quantitative estimation of metalaxyl in soils was based on a significant positive relationship between the radial growth of Phytophthora boehmeriae and the log concentration of the fungicide in the agar. The isolate of P. boehmeriae was chosen for its sensitivity to metalaxyl as manifested in a linear growth response on cornmeal agar over a range of 2 to 30 ng/ml. The sensitivity and quantitative nature of the bioassay was confirmed by comparison with data obtained by using 14 C-metalaxyl. Metabolism of metalaxyl was detected in three of five avocado soils that had repeated applications of the fungicide over 2-5 yr. The average disappearance of metalaxyl was 28 days, and in the most active soils was 14 days. The composition and level of the microbial populations of soils, either active or inactive in the breakdown of metalaxyl, did not differ. Fungal and bacterial microflora recovered from these two soils by use of either selective media or filtration techniques were capable of metabolizing metalaxyl over a 45-day period

  17. Efficiency Calibration of Phantom Family for Use in Direct Bioassay of Radionuclide in the Body

    International Nuclear Information System (INIS)

    Kim, Ji Seok; Ha, Wi Ho; Kim, Hyun Ki; Park, Gyung Deok; Lee, Jai Ki

    2008-01-01

    A major source of uncertainties of in vivo bioassay using a whole body counter calibrated against a body phantom containing known radioactivities is variation of counting geometry caused by the differences in body size of the subject from that of the phantom. Phantoms such as the BOMAB phantom are based on the body size of the reference man and usually single phantom is used in usual calibration of the counter. This is because it is difficult to apply a set of phantoms having different sizes. In order to reduce the potential errors due to variation of counting geometry, use of a set of phantoms having different body-shapes have been attempted. The efficiency files are stored in the computer analyzing the measurement data and a suitable one is retrieved for the specific subject. Experimental or computational approach can be employed in generation of the efficiency files. Carlan et al. demonstrated that Monte Carlo simulations can provide acceptable efficiencies by use of the IGOR phantom family. The body size of the individual subject undergoing in vivo bioassay should be determined by an appropriate method

  18. A Simple HPLC Bioanalytical Method for the Determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, accurate, and precise high performance chromatography (HPLC) method with spectrophotometric detection for the determination of doxorubicin hydrochloride in rat plasma. Methods: Doxorubicin hydrochloride and daunorubicin hydrochloride (internal standard, IS) were separated on a C18 ...

  19. Fast and accurate semantic annotation of bioassays exploiting a hybrid of machine learning and user confirmation.

    Science.gov (United States)

    Clark, Alex M; Bunin, Barry A; Litterman, Nadia K; Schürer, Stephan C; Visser, Ubbo

    2014-01-01

    Bioinformatics and computer aided drug design rely on the curation of a large number of protocols for biological assays that measure the ability of potential drugs to achieve a therapeutic effect. These assay protocols are generally published by scientists in the form of plain text, which needs to be more precisely annotated in order to be useful to software methods. We have developed a pragmatic approach to describing assays according to the semantic definitions of the BioAssay Ontology (BAO) project, using a hybrid of machine learning based on natural language processing, and a simplified user interface designed to help scientists curate their data with minimum effort. We have carried out this work based on the premise that pure machine learning is insufficiently accurate, and that expecting scientists to find the time to annotate their protocols manually is unrealistic. By combining these approaches, we have created an effective prototype for which annotation of bioassay text within the domain of the training set can be accomplished very quickly. Well-trained annotations require single-click user approval, while annotations from outside the training set domain can be identified using the search feature of a well-designed user interface, and subsequently used to improve the underlying models. By drastically reducing the time required for scientists to annotate their assays, we can realistically advocate for semantic annotation to become a standard part of the publication process. Once even a small proportion of the public body of bioassay data is marked up, bioinformatics researchers can begin to construct sophisticated and useful searching and analysis algorithms that will provide a diverse and powerful set of tools for drug discovery researchers.

  20. Fast and accurate semantic annotation of bioassays exploiting a hybrid of machine learning and user confirmation

    Directory of Open Access Journals (Sweden)

    Alex M. Clark

    2014-08-01

    Full Text Available Bioinformatics and computer aided drug design rely on the curation of a large number of protocols for biological assays that measure the ability of potential drugs to achieve a therapeutic effect. These assay protocols are generally published by scientists in the form of plain text, which needs to be more precisely annotated in order to be useful to software methods. We have developed a pragmatic approach to describing assays according to the semantic definitions of the BioAssay Ontology (BAO project, using a hybrid of machine learning based on natural language processing, and a simplified user interface designed to help scientists curate their data with minimum effort. We have carried out this work based on the premise that pure machine learning is insufficiently accurate, and that expecting scientists to find the time to annotate their protocols manually is unrealistic. By combining these approaches, we have created an effective prototype for which annotation of bioassay text within the domain of the training set can be accomplished very quickly. Well-trained annotations require single-click user approval, while annotations from outside the training set domain can be identified using the search feature of a well-designed user interface, and subsequently used to improve the underlying models. By drastically reducing the time required for scientists to annotate their assays, we can realistically advocate for semantic annotation to become a standard part of the publication process. Once even a small proportion of the public body of bioassay data is marked up, bioinformatics researchers can begin to construct sophisticated and useful searching and analysis algorithms that will provide a diverse and powerful set of tools for drug discovery researchers.

  1. A versatile and low-cost open source pipetting robot for automation of toxicological and ecotoxicological bioassays.

    Science.gov (United States)

    Steffens, Sebastian; Nüßer, Leonie; Seiler, Thomas-Benjamin; Ruchter, Nadine; Schumann, Mark; Döring, Ricarda; Cofalla, Catrina; Ostfeld, Avi; Salomons, Elad; Schüttrumpf, Holger; Hollert, Henner; Brinkmann, Markus

    2017-01-01

    In the past decades, bioassays and whole-organism bioassay have become important tools not only in compliance testing of industrial chemicals and plant protection products, but also in the monitoring of environmental quality. With few exceptions, such test systems are discontinuous. They require exposure of the biological test material in small units, such as multiwell plates, during prolonged incubation periods, and do not allow online read-outs. It is mostly due to these shortcomings that applications in continuous monitoring of, e.g., drinking or surface water quality are largely missing. We propose the use of pipetting robots that can be used to automatically exchange samples in multiwell plates with fresh samples in a semi-static manner, as a potential solution to overcome these limitations. In this study, we developed a simple and low-cost, versatile pipetting robot constructed partly using open-source hardware that has a small footprint and can be used for online monitoring of water quality by means of an automated whole-organism bioassay. We tested its precision in automated 2-fold dilution series and used it for exposure of zebrafish embryos (Danio rerio)-a common model species in ecotoxicology-to cadmium chloride and permethrin. We found that, compared to conventional static or semi-static exposure scenarios, effects of the two chemicals in zebrafish embryos generally occurred at lower concentrations, and analytically verified that the increased frequency of media exchange resulted in a greater availability of the chemical. In combination with advanced detection systems this custom-made pipetting robot has the potential to become a valuable tool in future monitoring strategies for drinking and surface water.

  2. A versatile and low-cost open source pipetting robot for automation of toxicological and ecotoxicological bioassays.

    Directory of Open Access Journals (Sweden)

    Sebastian Steffens

    Full Text Available In the past decades, bioassays and whole-organism bioassay have become important tools not only in compliance testing of industrial chemicals and plant protection products, but also in the monitoring of environmental quality. With few exceptions, such test systems are discontinuous. They require exposure of the biological test material in small units, such as multiwell plates, during prolonged incubation periods, and do not allow online read-outs. It is mostly due to these shortcomings that applications in continuous monitoring of, e.g., drinking or surface water quality are largely missing. We propose the use of pipetting robots that can be used to automatically exchange samples in multiwell plates with fresh samples in a semi-static manner, as a potential solution to overcome these limitations. In this study, we developed a simple and low-cost, versatile pipetting robot constructed partly using open-source hardware that has a small footprint and can be used for online monitoring of water quality by means of an automated whole-organism bioassay. We tested its precision in automated 2-fold dilution series and used it for exposure of zebrafish embryos (Danio rerio-a common model species in ecotoxicology-to cadmium chloride and permethrin. We found that, compared to conventional static or semi-static exposure scenarios, effects of the two chemicals in zebrafish embryos generally occurred at lower concentrations, and analytically verified that the increased frequency of media exchange resulted in a greater availability of the chemical. In combination with advanced detection systems this custom-made pipetting robot has the potential to become a valuable tool in future monitoring strategies for drinking and surface water.

  3. Sensitivity and specificity of the bioassay of estrogenicity in mammary gland and seminal vesicles of male mice

    Czech Academy of Sciences Publication Activity Database

    Škarda, Josef

    2002-01-01

    Roč. 51, č. 3 (2002), s. 267-276 ISSN 0862-8408 R&D Projects: GA ČR GA523/99/0843; GA AV ČR KSK5020115 Keywords : bioassay * estrogenicity * mammary gland Subject RIV: ED - Physiology Impact factor: 0.984, year: 2002

  4. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays.

    Science.gov (United States)

    Farenhorst, Marit; Knols, Bart G J

    2010-01-20

    Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers with accurate effective spore concentrations. The mosquito bioassay

  5. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays

    Directory of Open Access Journals (Sweden)

    Knols Bart GJ

    2010-01-01

    Full Text Available Abstract Background Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Methods Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. Results K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. Conclusions K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers

  6. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Development and Validation of a RP-HPLC Method for the Simultaneous Determination of Rifampicin and a Flavonoid Glycoside - A Novel ... range, accuracy, precision, limit of detection, limit of quantification, robustness and specificity.

  7. In situ and laboratory bioassays with Chironomus riparius larvae to assess toxicity of metal contamination in rivers: the relative toxic effect of sediment versus water contamination.

    Science.gov (United States)

    Faria, Mafalda S; Lopes, Ricardo J; Nogueira, António J A; Soares, Amadeu M V M

    2007-09-01

    We used bioassays employing head capsule width and body length increase of Chironomus riparius larvae as end points to evaluate metal contamination in streams. Bioassays were performed in situ near an abandoned Portuguese goldmine in the spring of 2003 and 2004. Bioassays also were performed under laboratory conditions with water and sediment collected from each stream to verify if laboratory bioassays could detect in situ toxicity and to evaluate the relative contribution of sediment and water to overall toxicity. We used field sediments with control water and control sediments with field water to discriminate between metal contamination in water and sediment. Field water with dry and sieved, organic matter-free, and nontreated sediments was used to determine the toxicity of heavy metals that enter the organism through ingested material. In both in situ and laboratory bioassays, body length increase was significantly inhibited by metal contamination, whereas head capsule width was not affected. Body length increase was more affected by contaminated sediment compared to contaminated water. The lowest-effect level of heavy metals was observed in the dry and sieved sediment that prevented ingestion of sediment particles by larvae. These results suggest that body length increase of C. riparius larvae can be used to indicate the impact of metal contamination in rivers. Chironomus riparius larvae are more affected by heavy metals that enter the organism through ingested sediment than by heavy metals dissolved in the water column. Nevertheless, several factors, such as the particle size and organic matter of sediment, must be taken into account.

  8. Bioactivity assays and application of 125I labeled human mouse chimeric anti-CD22 monoclonal antibody SM03

    International Nuclear Information System (INIS)

    Lu Pingping; Meng Zhiyun; Dou Guifang; Wu Yingliang; Wang Minwei

    2008-01-01

    To investigate the bioactivity and application of 125 I labeled human mouse chimeric monoclonal SM03, SM03 was labeled with 125 I using Indogen method. The labeled mixture was purified by Sephacryl S-300 HR separation chromospectry. The purity and concentration of separated fractions were determined by HPLC and Protein Assay Kit, respectively. Competitive binding method and ELISA method were used for bioactivity assays. 125 I-SM03 was applied to screen cell lines which express the most abundant CD22 antigen. The purity and recovery of 125 I-SM03 were >99% and >47%, respectively. The bioactivity of 125 I- SM03 and SM03 hasn't significant difference in statistics. Ramos cell line had the strongest special radioactivity when 125 I-SM03 bound with in Raji, Daudi and Ramos cell lines. Indogen method is a good way to label Human mouse chimeric anti-CD22 monoclonal antibody SM03 and the label will not affect the activity of SM03. The 125 I-SM03 not only can be used for detect agent, but also may be put into market for NHL therapy. (authors)

  9. ANALISIS RESIDU KLORPIRIFOS DALAM SAYUR-SAYURAN DENGAN TEKNIK HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC

    Directory of Open Access Journals (Sweden)

    Aman Sentosa Panggabean

    2016-06-01

    Full Text Available The research about analysis of chlorpyrifos residue in vegetables by using High Performance Liquid Chromatography (HPLC technique has been done. To obtain the optimal measurement results, the measurement performed several important parameters in the chromatographic system was composition of mobile phase, volume injection sample, flow rate and pH eluent. Optimum measurement conditions obtained was mobile phase composition (water : methanol with 70 : 30, volume injection sample are 5 mL, flow rate are 0.5mL/menit and pH eluent are 7. The analytical performance that obtained is good showed with the reproducibility value as percentage coefficient variance (% CV was 0.0664%, limit of detection (LOD was 0.44 ppm, with a recovery percentage of > 95%. The results obtained showed the HPLC technique can be used for the routine analysis in the determination of chlorpyrifos for the vegetable samples. Keywords: Chlorpyrifos, Vegetables, HPLC.

  10. Pungency Quantitation of Hot Pepper Sauces Using HPLC

    Science.gov (United States)

    Betts, Thomas A.

    1999-02-01

    A class of compounds known as capsaicinoids are responsible for the "heat" of hot peppers. To determine the pungency of a particular pepper or pepper product, one may quantify the capsaicinoids and relate those concentrations to the perceived heat. The format of the laboratory described here allows students to collectively develop an HPLC method for the quantitation of the two predominant capsaicinoids (capsaicin and dihydrocapsaicin) in hot-pepper products. Each small group of students investigated one of the following aspects of the method: detector wavelength, mobile-phase composition, extraction of capsaicinoids, calibration, and quantitation. The format of the lab forced students to communicate and cooperate to develop this method. The resulting HPLC method involves extraction with acetonitrile followed by solid-phase extraction clean-up, an isocratic 80:20 methanol-water mobile phase, a 4.6 mm by 25 cm C-18 column, and UV absorbance detection at 284 nm. The method developed by the students was then applied to the quantitation of capsaicinoids in a variety of hot pepper sauces. Editor's Note on Hazards in our April 2000 issue addresses the above.

  11. HPLC assisted Raman spectroscopic studies on bladder cancer

    Science.gov (United States)

    Zha, W. L.; Cheng, Y.; Yu, W.; Zhang, X. B.; Shen, A. G.; Hu, J. M.

    2015-04-01

    We applied confocal Raman spectroscopy to investigate 12 normal bladder tissues and 30 tumor tissues, and then depicted the spectral differences between the normal and the tumor tissues and the potential canceration mechanism with the aid of the high-performance liquid chromatographic (HPLC) technique. Normal tissues were demonstrated to contain higher tryptophan, cholesterol and lipid content, while bladder tumor tissues were rich in nucleic acids, collagen and carotenoids. In particular, β-carotene, one of the major types of carotenoids, was found through HPLC analysis of the extract of bladder tissues. The statistical software SPSS was applied to classify the spectra of the two types of tissues according to their differences. The sensitivity and specificity of 96.7 and 66.7% were obtained, respectively. In addition, different layers of the bladder wall including mucosa (lumps), muscle and adipose bladder tissue were analyzed by Raman mapping technique in response to previous Raman studies of bladder tissues. All of these will play an important role as a directive tool for the future diagnosis of bladder cancer in vivo.

  12. Photoprotective effect of vitamins A and E on polyamine and oxygenated free radical metabolism in hairless mouse epidermis.

    Science.gov (United States)

    Khettab, N; Amory, M C; Briand, G; Bousquet, B; Combre, A; Forlot, P; Barey, M

    1988-12-01

    The purpose of this study was to confirm the photoprotective effect on skin of vitamins A and E, due to inhibition of polyamine synthesis and production of free radicals. These variables were measured in the lumbar epidermis of the female hairless mouse subjected to UVA + B irradiation. Polyamines were assayed in epidermal homogenate by HPLC, and production of oxygenated free radicals was determined by spectrofluorometric assay of malonyl dialdehyde. It was determined that butyl-hydroxy-toluene and vitamin E inhibited production of free radicals (56% and 60%, respectively) and caused a significant reduction in polyamine biosynthesis (P less than 0.01), whereas the inhibitory effect of malonyl dialdehyde induced by vitamin A (30%) had no associated effect on polyamine metabolism.

  13. Insecticidal effect of plant extracts on Phlebotomus argentipes (Diptera: Psychodidae) in Bihar, India.

    Science.gov (United States)

    Dinesh, Diwakar Singh; Kumari, Seema; Pandit, Vibhishan; Kumar, Jainendra; Kumari, Nisha; Kumar, Prahlad; Hassan, Faizan; Kumar, Vijay; Das, Pradeep

    2015-12-01

    Phlebotomus argentipes (Diptera: Psychodidae), the established vector for kala-azar is presently being controlled by indoor residual spray of DDT in kala-azar endemic areas in India. Search for non-hazardous and non-toxic biodegradable active molecules from botanicals may provide cost-effective and eco-friendly alternatives to synthetic insecticides. The present study was aimed at evaluating various plant extracts from endemic and non-endemic areas of Bihar for their insecticidal activity against sandfly to identify the most effective plant extract. Bio-assay test was conducted with larvae and adult of P. argentipes with different plant extracts collected in distilled water, hexane, ethyl acetate, acetone and methanol. Thin layer chromatography (TLC), column chromatography and high performance liquid chromatography (HPLC) were conducted for detection of active molecules. Adults and larvae of sandflies exposed to the aqueous extract of Nicotiana tabacum resulted in 100 per cent mortality. The hexane extract of Clerodendrum infortunatum was found to kill 77 per cent adults but was ineffective against larvae. Bio-assay test of the ninth fraction (hexane extract-methanol phase) separated by column chromatography was found to be 63 per cent effective. The purple spot on the TLC of this fraction indicated the presence of a diterpenoid. HPLC of this fraction detected nine compounds with two peaks covering 20.44 and 56.52 per cent areas with retention time of 2.439 and 5.182 min, respectively supporting the TLC results. The column separated 9 [th] fraction of C. infortunatum extract was found to be effective in killing 63 per cent of adult P. argentipes. Compounds of this fraction need to be evaluated further for identification and characterization of the active molecule by conducting individual bio-assay tests followed by further fractionation and HPLC. Once the structure of the active molecule is identified and validated, it may be synthesized and formulated as a product.

  14. Early-stage bioassay for monitoring radioactive contamination in living livestock.

    Science.gov (United States)

    Yamaguchi, Toshiro; Sawano, Kaita; Kishimoto, Miori; Furuhama, Kazuhisa; Yamada, Kazutaka

    2012-12-01

    Soil samples from the ground surface and feces and blood from a mixed-breed male pig were collected on April 10, 2011 at a farm within 20 km of the Fukushima Daiichi nuclear power plant. The radioactivity of each sample was measured using a Ge semiconductor detector. Despite the fact that the pig had been fed non-contaminated imported feed, (131)I, (134)Cs and (137)Cs were detected in the feces, and (134)Cs and (137)Cs were detected in the blood clots. Because it is considerably difficult to measure radioactive contamination in the edible muscle of living livestock, bioassays are an option for the screening of radioactive contamination in living livestock to ensure food safety.

  15. Application of ABTS radical cation for selective on-line detection of radical scavengers in HPLC eluates

    NARCIS (Netherlands)

    Koleva, [No Value; Niederlander, HAG; van Beek, TA

    2001-01-01

    The radical cation 2,2 ' -azinobis-(3 -ethylbenzothiazoline-6-sulfonate), (ABTS(.+)) was utilized in an on-line HPLC method for the detection of radical scavengers in complex matrixes. The HPLC-separated analytes react postcolumn with the preformed ABTS(.+), and the induced bleaching is detected as

  16. Luciferase-Specific Coelenterazine Analogues for Optical Contamination-Free Bioassays.

    Science.gov (United States)

    Nishihara, Ryo; Abe, Masahiro; Nishiyama, Shigeru; Citterio, Daniel; Suzuki, Koji; Kim, Sung Bae

    2017-04-19

    Spectral overlaps among the multiple optical readouts commonly cause optical contamination in fluorescence and bioluminescence. To tackle this issue, we created five-different lineages of coelenterazine (CTZ) analogues designed to selectively illuminate a specific luciferase with unique luciferase selectivity. In the attempt, we found that CTZ analogues with ethynyl or styryl groups display dramatically biased bioluminescence to specific luciferases and pHs by modifying the functional groups at the C-2 and C-6 positions of the imidazopyradinone backbone of CTZ. The optical contamination-free feature was exemplified with the luciferase-specific CTZ analogues, which illuminated anti-estrogenic and rapamycin activities in a mixture of optical probes. This unique bioluminescence platform has great potential for specific and high throughput imaging of multiple optical readouts in bioassays without optical contamination.

  17. Bioassay method for toxicity studies of insecticide formulations to Tuta absoluta (meyrick, 1917)

    OpenAIRE

    Galdino, Tarcísio Visintin da Silva; Picanço, Marcelo Coutinho; Morais, Elisangela Gomes Fidelis de; Silva, Nilson Rodrigues; Silva, Geverson Aelton Rezende da; Lopes, Mayara Cristina

    2011-01-01

    Chemical control is the main method for controlling the tomato leafminer, Tuta absoluta (Meyrick, 1917) (Lepidoptera: Gelechiidae). Reported techniques for the evaluation of insecticide toxicity to the tomato leafminer are not in agreement with field conditions and do not allow us to verify whether doses used in the field are efficient for control. Thus, the objective of this work was to develop a bioassay methodology to study the toxicity of insecticide formulations to T. absoluta that repre...

  18. Bioassay method for toxicity studies of insecticide formulations to tuta absoluta (meyrick, 1917).

    OpenAIRE

    GALDINO, T. V. da S.; PICANÇO, M. C.; MORAIS, E. G. F. de; SILVA, N. R.; SILVA, G. A. R da; LOPES, M. C.

    2014-01-01

    Chemical control is the main method for controlling the tomato leafminer, Tuta absoluta (Meyrick, 1917) (Lepidoptera: Gelechiidae). Reported techniques for the evaluation of insecticide toxicity to the tomato leafminer are not in agreement with field conditions and do not allow us to verify whether doses used in the field are efficient for control. Thus, the objective of this work was to develop a bioassay methodology to study the toxicity of insecticide formulations to T. absoluta that repre...

  19. Mouse adhalin

    DEFF Research Database (Denmark)

    Liu, L; Vachon, P H; Kuang, W

    1997-01-01

    . To analyze the biological roles of adhalin, we cloned the mouse adhalin cDNA, raised peptide-specific antibodies to its cytoplasmic domain, and examined its expression and localization in vivo and in vitro. The mouse adhalin sequence was 80% identical to that of human, rabbit, and hamster. Adhalin...... was specifically expressed in striated muscle cells and their immediate precursors, and absent in many other cell types. Adhalin expression in embryonic mouse muscle was coincident with primary myogenesis. Its expression was found to be up-regulated at mRNA and protein levels during myogenic differentiation...

  20. Developmental status of bioassays in genetic toxicology: a report of Phase II of the US Environmental Protection Agency Gene-Tox program

    Energy Technology Data Exchange (ETDEWEB)

    Brusick, D; Auletta, A

    1985-01-01

    The Gene-Tox Program was structured around two phases of genetic test data evaluation. The first phase consisted of 36 Work Group reports, each evaluating the results and performance of a specific bioassay. The second phase consisted of a plan to summarize the information provided by the Work Groups. The Gene-Tox Coordinating Committee was to be responsible for Phase II, and several subgroups were assigned specific goals in implementing this analysis. This report deals with Goal I which is to identify the developmental status of the individual bioassays reviewed by the Gene-Tox Work Groups in the first phase of the Program. 5 references, 6 tables.

  1. Comparison of transferrin isoform analysis by capillary electrophoresis and HPLC for screening congenital disorders of glycosylation.

    Science.gov (United States)

    Dave, Mihika B; Dherai, Alpa J; Udani, Vrajesh P; Hegde, Anaita U; Desai, Neelu A; Ashavaid, Tester F

    2018-01-01

    Transferrin, a major glycoprotein has different isoforms depending on the number of sialic acid residues present on its oligosaccharide chain. Genetic variants of transferrin as well as the primary (CDG) & secondary glycosylation defects lead to an altered transferrin pattern. Isoform analysis methods are based on charge/mass variations. We aimed to compare the performance of commercially available capillary electrophoresis CDT kit for diagnosing congenital disorders of glycosylation with our in-house optimized HPLC method for transferrin isoform analysis. The isoform pattern of 30 healthy controls & 50 CDG-suspected patients was determined by CE using a Carbohydrate-Deficient Transferrin kit. The results were compared with in-house HPLC-based assay for transferrin isoforms. Transferrin isoform pattern for healthy individuals showed a predominant tetrasialo transferrin fraction followed by pentasialo, trisialo, and disialotransferrin. Two of 50 CDG-suspected patients showed the presence of asialylated isoforms. The results were comparable with isoform pattern obtained by HPLC. The commercial controls showed a <20% CV for each isoform. Bland Altman plot showed the difference plot to be within +1.96 with no systemic bias in the test results by HPLC & CE. The CE method is rapid, reproducible and comparable with HPLC and can be used for screening Glycosylation defects. © 2017 Wiley Periodicals, Inc.

  2. Laboratory algal bioassays using PAM fluorometry: effects of test conditions on the determination of herbicide and field sample toxicity.

    Science.gov (United States)

    Sjollema, Sascha B; van Beusekom, Sebastiaan A M; van der Geest, Harm G; Booij, Petra; de Zwart, Dick; Vethaak, A Dick; Admiraal, Wim

    2014-05-01

    Pulse Amplitude Modulation (PAM) fluorometry, based on chlorophyll a fluorescence, is a frequently used technique in algal bioassays to assess toxicity of single compounds or complex field samples. Several test conditions can influence the test results, and because a standardized test protocol is currently lacking, linking the results of different studies is difficult. Therefore, the aim of the present study was to gain insight into the effects of test conditions of laboratory algal bioassays using PAM fluorometry on the outcome of toxicity tests. To this purpose, we described the results from several pilot studies on test development in which information is provided on the effects of the main test factors during the pretest phase, the test preparation, the exposure period, and the actual measurement. The experiments were focused on individual herbicides and complex field samples and included the effects of culturing conditions, cell density, solvent concentration, exposure time, and the presence of actinic light. Several of these test conditions were found to influence the outcome of the toxicity test, and the presented information provides important background information for the interpretation of toxicity results and describes which test conditions should be taken into account when using an algal bioassay with PAM fluorometry. Finally, the application of PAM fluorometry in algal toxicity testing is discussed. © 2014 SETAC.

  3. HPLC determination of caffeine in coffee beverage

    Science.gov (United States)

    Fajara, B. E. P.; Susanti, H.

    2017-11-01

    Coffee is the second largest beverage which is consumed by people in the world, besides the water. One of the compounds which contained in coffee is caffeine. Caffeine has the pharmacological effect such as stimulating the central nervous system. The purpose of this study is to determine the level of caffeine in coffee beverages with HPLC method. Three branded coffee beverages which include in 3 of Top Brand Index 2016 Phase 2 were used as samples. Qualitative analysis was performed by Parry method, Dragendorff reagent, and comparing the retention time between sample and caffeine standard. Quantitative analysis was done by HPLC method with methanol-water (95:5v/v) as mobile phase and ODS as stationary phasewith flow rate 1 mL/min and UV 272 nm as the detector. The level of caffeine data was statistically analyzed using Anova at 95% confidence level. The Qualitative analysis showed that the three samples contained caffeine. The average of caffeine level in coffee bottles of X, Y, and Z were 138.048 mg/bottle, 109.699 mg/bottle, and 147.669 mg/bottle, respectively. The caffeine content of the three coffee beverage samples are statistically different (pcoffee beverage samples were not meet the requirements set by the Indonesian Standard Agency of 50 mg/serving.

  4. Analysis of D3-,4-,5-phosphorylated phosphoinositides using HPLC.

    Science.gov (United States)

    Munnik, Teun

    2013-01-01

    Detection of polyphosphoinositides (PPIs) is difficult due to their low chemical abundancy. This problem is further complicated by the fact that PPIs are present as various, distinct isomers, which are difficult, if not impossible, to separate by conventional thin layer chromatography (TLC) systems. PPIs in plants include PtdIns3P, PtdIns4P, PtdIns5P, PtdIns(3,5)P 2, and PtdIns(4,5)P 2. Here, a protocol is described analyzing plant PPIs using (32)P-orthophosphorus pre-labeled material. After extraction, lipids are deacylated and the resulting glycerophosphoinositol polyphosphates (GroPInsPs) separated by HPLC using a strong anion-exchange column and a shallow salt gradient. Alternatively, PPIs are first separated by TLC, the lipids reisolated, deacylated, and the GroPInsPs then separated by HPLC.

  5. An Efficient Method for the Preparative Isolation and Purification of Flavonoid Glycosides and Caffeoylquinic Acid Derivatives from Leaves of Lonicera japonica Thunb. Using High Speed Counter-Current Chromatography (HSCCC) and Prep-HPLC Guided by DPPH-HPLC Experiments.

    Science.gov (United States)

    Wang, Daijie; Du, Ning; Wen, Lei; Zhu, Heng; Liu, Feng; Wang, Xiao; Du, Jinhua; Li, Shengbo

    2017-02-02

    In this work, the n-butanol extract from leaves of Lonicera japonica Thunb. (L. japonica) was reacted with DPPH and subjected to a HPLC analysis for the guided screening antioxidants (DPPH-HPLC experiments). Then, nine antioxidants, including flavonoid glycosides and caffeoylquinic acid derivatives, were isolated and purified from leaves of L. japonica using high speed counter-current chromatography (HSCCC) and prep-HPLC. The n-butanol extract was firstly isolated by HSCCC using methyl tert-butyl ether/n-butanol/acetonitrile/water (0.5% acetic acid) (2:2:1:5, v/v), yielding five fractions F1, F2 (rhoifolin), F3 (luteoloside), F4 and F5 (collected from the column after the separation). The sub-fractions F1, F4 and F5 were successfully separated by prep-HPLC. Finally, nine compounds, including chlorogenic acid (1), lonicerin (2), rutin (3), rhoifolin (4), luteoloside (5), 3,4-Odicaffeoylquinic acid (6), hyperoside (7), 3,5-O-dicaffeoylquinic acid (8), and 4,5-O-dicaffeoylquinic acid (9) were obtained, respectively, with the purities over 94% as determined by HPLC. The structures were identified by electrospray ionization mass spectrometry (ESI-MS), 1H- and 13C-NMR. Antioxidant activities were tested, and the isolated compounds showed strong antioxidant activities.

  6. [Exploration on feasibility of introducing bioassay method into quality evaluation of Chinese herbal medicines by studying on the correlation between antioxidant activity of Prunella vulgaris and its total phenolic acids content for example].

    Science.gov (United States)

    Feng, Wei-Hong; Li, Chun; Xin, Wei-Mei; Lin, Li-Mei; Xia, Bo-Hou; Rong, Li-Xin; Yang, Li-Xin; Yi, Hong; Zhang, Yong-Xin; Chen, Liang-Mian; Wang, Zhi-Min

    2016-07-01

    of each organ of P. vulgaris and total phenolic acids content inside has a good linear correlation. Therefore, in certain quality range of crude drug, DPPH bioassay combined with HPLC content determination can be used for the quality control of P. vulgaris, as is a new method for the quality control of P. vulgaris. Copyright© by the Chinese Pharmaceutical Association.

  7. Recombinant cell bioassays for the detection of (gluco) corticosteroids and endocrine-disrupting potencies of several enviromental PCB contaminants

    NARCIS (Netherlands)

    Bovee, T.F.H.; Helsdingen, J.R.; Hamers, A.R.M.; Brouwer, B.A.; Nielen, M.W.F.

    2011-01-01

    Sensitive and robust bioassays for glucocorticoids are very useful for the pharmaceutical industry, environmental scientists and veterinary control. Here, a recombinant yeast cell was constructed that expresses the human glucocorticoid receptor alpha and a green fluorescent reporter protein in

  8. [Comparison between colorimetry and HPLC on the stability test of roxithromycin].

    Science.gov (United States)

    Wei, Z P; Mao, S R; Bi, D Z

    2000-11-01

    To compare the stability of roxithromycin in solutions of different pH. Roxithromycin solutions of different pH were prepared with water, simulate intestinal fluid (SIF) and simulate gastric fluid (SGF) shown to be the stability of these solutions were tested by colorimetry and HPLC. Roxithromycin was stable in water, SGF and SIF determined by colorimetry. However, it was found to be stable only in water and SIF but unstable in SGF as determined by HPLC. Roxithromycin is unstable in acidic medium like SGF. The metabolite of roxithromycin showed unfavorable interference on the assay of roxithromycin when colorimetry was used. Colorimetry can not be used for the determination and assay of roxithromycin in acidic solution like SGF.

  9. Simultaneous detection of water-soluble vitamins using the High Performance Liquid Chromatography (HPLC - a review

    Directory of Open Access Journals (Sweden)

    Rosemond Godbless Dadzie

    2014-01-01

    Full Text Available The water-soluble vitamins (WSV: ascorbic acid (vitamin C, thiamine (B1, riboflavin (B2, niacin (B3, panthothenic acid (B5, pyridoxine, and pyridoxal (B6, folic acid (B9, biotin(B8 , and B12 are very essential in the diet of humankind. As a result of ever increasing pressures from both consumers and legal enforcers, to specify accurately nutritive compositions of WSV that are present in food materials, many researchers have attempted to fill this niche through the provision of highly sensitive and rapid high performance liquid chromatography (HPLC procedures. In view of the health benefits of WSV, a replete of HPLC methods have been developed for simultaneous determination of their contents in nature and fortified food samples, nutritional supplements, as well as blood plasmas. The rate of losses of these vitamins during food processing and analysis, in addition to their transient dynamics, presents complexities in developing a highly sensitive HPLC procedure for their simultaneous separations and assays. This review critically assesses the different HPLC procedures developed by researchers and available in the open literature for simultaneous determination of water-soluble vitamins (WSV in dried tropical fruits materials. The study revealed that not a single chromatographic run developed by researchers can simultaneously elute all the WSV at a time. However, the HPLC procedures that are capable of determining all the WSV were coupled with electrospray ionization mass spectroscopy (ESI-MS, thus making the set-up expensive.

  10. HPLC-DAD determination of imidacloprid in onion

    OpenAIRE

    Mandić Aljoša; Lazić Sanja; Inđić Dušanka

    2003-01-01

    Imidacloprid is an insecticide most commonly used on vegetables, potato sugar beet, fruit, cereal, maize and rice. Imidacloprid residue has been determined in spiked onion and in onion samples. Sample preparation consisted of dichlormethane extraction of imidacloprid from onion, followed by purification of the obtained extract on a LC-Florisil disposable cartridge. The HPLC-DAD method bas been developed on reversed-phase for separation of imidacloprid with a mixture of 0.01 M phosphate buffer...

  11. Determination of carbonyl compounds in air by HPLC; Determinacion de compuestos carbonilicos en aire por HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, S; Perez, R M; Campos, A; Gonzalez, D

    1995-07-01

    A method for the determination of seven carbonyl compounds in air is presented. The procedure involve sampling of air by a Sep-Pak Cartridge impregnated with 2,4-dinitrophenylhydrazine. Elution was done with 3 mL of acetonitrile and the eluate was diluted to 5 mL. The analysis was done by HPLC with UV detection and external standard method quantification. It has been achieved relative standard deviations about 5% and detection limits of 80 ng/cartridge for formaldehyde, acetaldehyde and acetoacetonitrile. Three different types of samples (rural, urban, petrol emission) were successfully analyzed. (Author) 12 refs.

  12. Application of bioassays to evaluate a copper contaminated soil before and after a pilot-scale electrokinetic remediation

    Energy Technology Data Exchange (ETDEWEB)

    Wang Quanying [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Zhou Dongmei [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China)], E-mail: dmzhou@issas.ac.cn; Cang Long [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Sun Tianran [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China)

    2009-02-15

    Remediation programmes are considered to be complete when human risk-based criteria are met. However, these targets are often unsatisfied with the ecological parameters that may be important with regard to future soil use. Five soil subsamples, collecting along a pilot-scale soil column after electrokinetic treatment, were studied, from which about 42.0%-93.3% soil Cu had been successfully removed. A series of biological assays including soil microbial biomass carbon, basal soil respiration, soil urease activity, earthworm assays, and seed assays were used to evaluate their ecological risks. The results showed that the bioassay data from the treatment variants did not supposedly reflecting the decreased soil Cu concentrations after the electrokinetic treatment, but were highly correlated with some soil physicochemical characteristics. It suggests that bioassays are necessary to assess the ecotoxicity of soil after electrokinetic treatment. - There has been a motivation towards using biological indicators for risk assessment of contaminated soil after electrokinetic remediation.

  13. Application of bioassays to evaluate a copper contaminated soil before and after a pilot-scale electrokinetic remediation

    International Nuclear Information System (INIS)

    Wang Quanying; Zhou Dongmei; Cang Long; Sun Tianran

    2009-01-01

    Remediation programmes are considered to be complete when human risk-based criteria are met. However, these targets are often unsatisfied with the ecological parameters that may be important with regard to future soil use. Five soil subsamples, collecting along a pilot-scale soil column after electrokinetic treatment, were studied, from which about 42.0%-93.3% soil Cu had been successfully removed. A series of biological assays including soil microbial biomass carbon, basal soil respiration, soil urease activity, earthworm assays, and seed assays were used to evaluate their ecological risks. The results showed that the bioassay data from the treatment variants did not supposedly reflecting the decreased soil Cu concentrations after the electrokinetic treatment, but were highly correlated with some soil physicochemical characteristics. It suggests that bioassays are necessary to assess the ecotoxicity of soil after electrokinetic treatment. - There has been a motivation towards using biological indicators for risk assessment of contaminated soil after electrokinetic remediation

  14. GlycoExtractor: a web-based interface for high throughput processing of HPLC-glycan data.

    Science.gov (United States)

    Artemenko, Natalia V; Campbell, Matthew P; Rudd, Pauline M

    2010-04-05

    Recently, an automated high-throughput HPLC platform has been developed that can be used to fully sequence and quantify low concentrations of N-linked sugars released from glycoproteins, supported by an experimental database (GlycoBase) and analytical tools (autoGU). However, commercial packages that support the operation of HPLC instruments and data storage lack platforms for the extraction of large volumes of data. The lack of resources and agreed formats in glycomics is now a major limiting factor that restricts the development of bioinformatic tools and automated workflows for high-throughput HPLC data analysis. GlycoExtractor is a web-based tool that interfaces with a commercial HPLC database/software solution to facilitate the extraction of large volumes of processed glycan profile data (peak number, peak areas, and glucose unit values). The tool allows the user to export a series of sample sets to a set of file formats (XML, JSON, and CSV) rather than a collection of disconnected files. This approach not only reduces the amount of manual refinement required to export data into a suitable format for data analysis but also opens the field to new approaches for high-throughput data interpretation and storage, including biomarker discovery and validation and monitoring of online bioprocessing conditions for next generation biotherapeutics.

  15. Ellagitannin composition of blackberry as determined by HPLC-ESI-MS and MALDI-TOF-MS.

    Science.gov (United States)

    Hager, Tiffany J; Howard, Luke R; Liyanage, Rohana; Lay, Jackson O; Prior, Ronald L

    2008-02-13

    Blackberries ( Rubus sp.) were evaluated by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF-MS) to identify the ellagitannins present in flesh, torus (receptacle tissue), and seeds. Most ellagitannins were present (or detectable) only in seed tissues. Ellagitannins identified by HPLC-ESI-MS in the seeds included pedunculagin, casuarictin/potentillin, castalagin/vescalagin, lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D. For several of the ellagitannins, isomeric separation was also obtained. The MALDI-TOF-MS analysis was primarily utilized to evaluate and identify high molecular mass (>1000 Da) ellagitannins. The MALDI analysis verified the presence of the ellagitannins identified by HPLC-ESI-MS including lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D, but the analysis also indicated the presence of several other compounds that were most likely ellagitannins based on the patterns observed in the masses (i.e., loss or addition of a gallic acid moiety to a known ellagitannin). This study determined the presence of several possible isomeric forms of ellagitannins previously unidentified in fruit and presents a possible analytical HPLC method for the analysis of the major ellagitannins present in the fruit.

  16. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  17. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  18. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    Science.gov (United States)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  19. Evaluation of internal exposure of nuclear medicine staff through in vivo and in vitro bioassay techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, E.A.; Araujo, F.; Sousa, W.O.; Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioprotecao e Dosimetria, CNEN, Av. Salvador Allende s/n, CEP 22780-160 Rio de Janeiro (Brazil); Rebelo, A.M.O.; Corbo, R. [Hospital Universitario Clementino Fraga Filho, HU-UFRJ, Av. Brigadeiro Trompowsky, s/n, ILHA do Fundao, CEP 21945-560, Rio de Janeiro, RJ (Brazil)

    2007-07-01

    The manipulation of a wide variety of unsealed sources in Nuclear Medicine results in a significant risk of internal exposure of the workers. {sup 131}I should be highlighted among the most frequently used radionuclides because of its large application for diagnosis and therapy of thyroid diseases. The increasing use of radionuclides for medical purposes creates a demand for feasible methodologies to perform occupational control of internal contamination. Currently in Brazil, there are {approx}300 nuclear medicine centres in operation but individual monitoring is still restricted to the control of external exposure. This work presents the development of in vivo and in vitro bioassay techniques aimed to quantify incorporation of radionuclides used in Nuclear Medicine. It is also presented the results of a preliminary survey of internal exposure of a group of workers involved in the preparation of therapeutic doses of {sup 131}I. Workers were monitored with a gamma camera available in the Nuclear Medicine Service of the University Hospital of Rio de Janeiro and at the Institute of Radiation Protection and Dosimetry Whole-Body Counter (IRDWBC). The in vivo detection systems were calibrated with a neck-thyroid phantom developed in IRD. Urine samples from radiopharmacy workers were collected after preparation and administration of therapeutic doses (10-250 mCi) of {sup 131}I and measured with a HPGe detection system available in the Bioassay Laboratory of IRD. The results show that the bioassay methods developed in this work present enough sensitivity for routine monitoring of nuclear medicine workers. All workers monitored in this survey presented positive results for {sup 131}I in urine samples and two workers presented detectable activities in thyroid when measured at the IRD-WBC. The highest committed effective dose per preparation was estimated to be 17 {mu}Sv. (authors)

  20. Quantification of furanoheliangolides by HPLC and GC Quantificação dos furanoeliangolidos por HPLC e CG

    OpenAIRE

    Pierre Alexandre dos Santos; Izabel Cristina Casanova Turati; José Carlos Tomaz; Norberto Peporine Lopes

    2003-01-01

    The development and comparison of two analytical methods (HPLC and GC) for the quantification of the most common furanoheliangolides from Lychnophora is reported in this paper. Both methods are sensitive and suitable for quantification of these metabolites.Neste trabalho são descritos o desenvolvimento e comparação de dois métodos analíticos (CLAE e CG) para quantificação dos furanoeliangolidos mais comuns em Lychnophora.Ambos os métodos são sensíveis e adequados para a quantificação desses m...

  1. 'In-vivo' and bioassay results from two contrasting cases of plutonium-239 inhalation

    International Nuclear Information System (INIS)

    Ramsden, D.; Bains, M.E.D.; Fraser, D.C.

    1969-06-01

    'In-vivo' and bioassay measurements following two incidents involving plutonium-239 inhalation are described and contrasted. Incident 1, involving the inhalation of insoluble plutonium oxide, resulted in a lung content of about 20 nCi after the initial clearance. Urine excretion was negligible and the estimation of exposure was based on 'in-vivo' data and faecal excretion. Incident,2, involving the inhalation of soluble plutonium, proved negligible and the estimation of exposure, based on urinary excretion, was 0.6 nCi. (author)

  2. [Determination of genkwanin in flos Genkwa by HPLC].

    Science.gov (United States)

    Zhang, B; Yuan, S; Xia, K

    1996-04-01

    In this paper, the method for determining genkwanin in Flos Genkwa was established by HPLC. Detected at 332nm on a Lichrosorb 5 RP-18 column with a mobile phase of methanol-water-acetic acid (65:35:5), the content of genkwanin in Flos Genkwa was determined to be 0.16%. The recovery rate was 95.46% and RSD 1.15%.

  3. Application of Pattern Recognition Method for Color Assessment of Oriental Tobacco based on HPLC of Polyphenols

    Directory of Open Access Journals (Sweden)

    Dagnon S

    2014-12-01

    Full Text Available The color of Oriental tobaccos was organoleptically assayed, and high performance liquid chromatography (HPLC of polyphenols was performed. The major tobacco polyphenols (chlorogenic acid, its isomers, and rutin, as well as scopoletin and kaempferol-3-rutinoside were quantified. HPLC polyphenol profiles were processed by pattern recognition method (PRM, and the values of indexes of similarity (Is,% between the cultivars studied were determined. It was shown that data from organoleptic color assessment and from PRM based on HPLC profiles of polyphenols of the cultivars studied are largely compatible. Hence, PRM can be suggested as an additional tool for objective color evaluation and classification of Oriental tobacco.

  4. Guide to the bioassay of uranium at uranium mine-mill facilities

    International Nuclear Information System (INIS)

    1981-01-01

    As a result of occupational exposure, uranium may be taken into the body by inhalation, ingestion or absorption through skin wounds. The organs at risk are the lung, kidney, and bones. Analysis of urine samples for uranium is recommended on a regular monthly basis, before and after a rest period, and it is suggested that a worker be removed from a working area if a level above 300 μg/l is found before a rest period, or 150 μg/l after a rest period. Background information on the development of a bioassay program is given, and a recommended program for uranium mine and mill facilities is included. (L.L.)

  5. Ciclosporine A asxay: RIA or HPLC, plasma or total blood

    International Nuclear Information System (INIS)

    Lapalus, P.; Garraffo, R.; Krebs, B.; Lapalus, F.

    1985-01-01

    The two methods now in force for ciclosporine A assay are radioimmunoassay (RIA) and high pressure liquid chromatography (HPLC) in various biological media (plasma, serum, total blood). The advantages and disadvantages of the two methods are presented [fr

  6. Part 2. Assessment of genotoxicity after exposure to diesel exhaust from U.S. 2007-compliant diesel engines: report on 1- and 3-month exposures in the ACES bioassay.

    Science.gov (United States)

    Bemis, Jeffrey C; Torous, Dorothea K; Dertinger, Stephen D

    2012-09-01

    genotoxicity. Statistical approaches employed analysis of variance (ANOVA) to compare effects of sex, exposure condition, and duration, as well as their interactions. This initial assessment of MN was performed on both mouse and rat blood samples from the 1-month and 3-month exposures. The data from mice demonstrate the well established, sex-based difference in MN-RET and MN-NCE frequencies regularly observed in this species, with females exhibiting slightly lower frequencies. There were no sex-based differences observed in rats. An examination of the mean frequencies across the exposure groups and durations of exposure did not show an appreciable induction of MN at the 1- or 3-month exposures in either species. Further statistical analyses did not reveal any significant exposure-related effects. An examination of the potential genotoxic effects of DE is clearly valuable as part of a large-scale chronic-exposure bioassay. The data and observations from the 1-and 3-month exposure studies will eventually be combined with the results from the 1- and 2-year exposure studies to provide a comprehensive examination of chronic exposure to DE in a rodent model. This examination of chromosome damage serves an important role in the context of the entire ACES bioassay, which was designed to assess the safety of diesel combustion engines.

  7. Bioassays with caged hyalella azteca to determine in situ toxicity downstream of two Saskatchewan, Canada, uranium operations.

    Science.gov (United States)

    Robertson, Erin L; Liber, Karsten

    2007-11-01

    The main objectives of this in situ study were to evaluate the usefulness of an in situ bioassay to determine if downstream water bodies at the Key Lake and Rabbit Lake uranium operations (Saskatchewan, Canada) were toxic to Hyalella azteca and, if toxicity was observed, to differentiate between the contribution of surface water and sediment contamination to in situ toxicity. These objectives were achieved by performing 4-d in situ bioassays with laboratory-reared H. azteca confined in specially designed, paired, surface water and sediment exposure chambers. Results from the in situ bioassays revealed significant mortality, relative to the respective reference site, at the exposure sites at both Key Lake (p

  8. Plant genotoxicity: a molecular cytogenetic approach in plant bioassays.

    Science.gov (United States)

    Maluszynska, Jolanta; Juchimiuk, Jolanta

    2005-06-01

    It is important for the prevention of DNA changes caused by environment to understand the biological consequences of DNA damages and their molecular modes of action that lead to repair or alterations of the genetic material. Numerous genotoxicity assay systems have been developed to identify DNA reactive compounds. The available data show that plant bioassays are important tests in the detection of genotoxic contamination in the environment and the establishment of controlling systems. Plant system can detect a wide range of genetic damage, including gene mutations and chromosome aberrations. Recently introduced molecular cytogenetic methods allow analysis of genotoxicity, both at the chromosomal and DNA level. FISH gives a new possibility of the detection and analysis of chromosomal rearrangements in a great detail. DNA fragmentation can be estimated using the TUNEL test and the single cell gel electrophoresis (Comet assay).

  9. SCREENING CORD BLOOD FOR HEMOGLOBINOPATHIES AND THALASSEMIA BY HPLC

    NARCIS (Netherlands)

    VANDERDIJS, FPL; VANDENBERG, GA; SCHERMER, JG; MUSKIET, FD; LANDMAN, H; MUSKIET, FAJ

    We evaluated the use of an HPLC method for screening hemoglobins in cord blood. We studied the genotype frequencies of the structural hemoglobin variants HbS and HbC and the synthesis variants alpha- and beta+-thalassemia in babies born on Curacao. During three months, 67.2% of all (748) newborns

  10. Use of HPLC with flow-through radiometric detection for low level environmental analysis

    International Nuclear Information System (INIS)

    Mao, J.; Fackler, P.H.

    1992-01-01

    High Performance Liquid Chromatography with flow-through radiometric detection (HPLC-RAM) is increasingly becoming a standard analytical technique in pharmaceutical, agricultural and chemical industries for monitoring radiolabeled analytes. This paper focuses on the applications of this flow-through radiochromatographic technique for low level aquatic toxicology and environmental fate testing. Examples include parts per billion water, sediment/soil and fish tissue analyses using reverse phase as well as normal phase HPLC. The applications of both homogeneous (liquid) and heterogeneous (solid) flow cell scintillation counting are addressed. Compounds discussed are primarily pesticides and pharmaceuticals

  11. The use of dihexyldithiocarbamate in reverse-phase HPLC of metal chelates

    Science.gov (United States)

    Fatimah, S. S.; Bahti, H. H.; Hastiawan, I.; Permanasari, A.

    2018-05-01

    Dialkyldithiocarbamates have long been used as chelating agents in reverse-phase HPLC of transition metals. In the previous study, an alkyl homolog of this type of ligand, namely dihexyldithiocarbamate (DHDTC), was synthesized and characterized. The use of this particular ligand in the revese-phase HPLC of some selected transition metal ions is now reported for the first time. The mobile phase comprising of the flow rate and of the detection, in the separation of the metal chelates of Cd (II), Fe (III), Cu (II), and Co (III), were investigated on a C-18 column. The results showed that dihexylditiocarbamate could be used for separating Cd (II), Fe(III), Cu(II), and Co(III). Therefore, it could be used in simultaneous analysis.

  12. Optimisation of the microplate resazurin assay for screening and bioassay-guided fractionation of phytochemical extracts against Mycobacterium tuberculosis.

    Science.gov (United States)

    O'Neill, Taryn E; Li, Haoxin; Colquhoun, Caitlyn D; Johnson, John A; Webster, Duncan; Gray, Christopher A

    2014-01-01

    Because of increased resistance to current drugs, there is an urgent need to discover new anti-mycobacterial compounds for the development of novel anti-tuberculosis drugs. The microplate resazurin assay (MRA) is commonly used to evaluate natural products and synthetic compounds for anti-mycobacterial activity. However, the assay can be problematic and unreliable when screening methanolic phytochemical extracts. To optimise the MRA for the screening and bioassay-guided fractionation of phytochemical extracts using Mycobacterium tuberculosis H37Ra. The effects of varying assay duration, resazurin solution composition, solvent (dimethyl sulphoxide - DMSO) concentration and type of microtitre plate used on the results and reliability of the MRA were investigated. The optimal bioassay protocol was applied to methanolic extracts of medicinal plants that have been reported to possess anti-mycobacterial activity. The variables investigated were found to have significant effects on the results obtained with the MRA. A standardised procedure that can reliably quantify anti-mycobacterial activity of phytochemical extracts in as little as 48 h was identified. The optimised MRA uses 2% aqueous DMSO, with an indicator solution of 62.5 µg/mL resazurin in 5% aqueous Tween 80 over 96 h incubation. The study has identified an optimal procedure for the MRA when used with M. tuberculosis H37Ra that gives rapid, reliable and consistent results. The assay procedure has been used successfully for the screening and bioassay-guided fractionation of anti-mycobacterial compounds from methanol extracts of Canadian medicinal plants. Copyright © 2014 John Wiley & Sons, Ltd.

  13. A uHPLC-MS mathematical modeling approach to dry powder inhaler single agglomerate analysis.

    Science.gov (United States)

    Pennington, Justin; Lena, John; Medendorp, Joseph; Ewing, Gary

    2011-10-01

    Demonstration of content uniformity (CU) is critical toward the successful development of dry powder inhalers (DPIs). Methods for unit dose CU determination for DPI products are well-established within the field of respiratory science. Recent advances in the area include a uHPLC-MS method for high-throughput uniformity analysis, which allows for a greater understanding of blending operations as the industry transitions to a quality-by-design approach to development. Further enhancements to this uHPLC-MS method now enable it to determine CU and sample weight at the single agglomerate level, which is roughly 50× smaller than a unit dose. When coupled with optical microscopy-based agglomerate sizing, the enhanced uHPLC-MS method can also predict the density and porosity of individual agglomerates. Expanding analytical capabilities to the single agglomerate level provides greater insights and confidence in the DPI manufacturing process.

  14. Mixture effects in samples of multiple contaminants - An inter-laboratory study with manifold bioassays.

    Science.gov (United States)

    Altenburger, Rolf; Scholze, Martin; Busch, Wibke; Escher, Beate I; Jakobs, Gianina; Krauss, Martin; Krüger, Janet; Neale, Peta A; Ait-Aissa, Selim; Almeida, Ana Catarina; Seiler, Thomas-Benjamin; Brion, François; Hilscherová, Klára; Hollert, Henner; Novák, Jiří; Schlichting, Rita; Serra, Hélène; Shao, Ying; Tindall, Andrew; Tolefsen, Knut-Erik; Umbuzeiro, Gisela; Williams, Tim D; Kortenkamp, Andreas

    2018-05-01

    Chemicals in the environment occur in mixtures rather than as individual entities. Environmental quality monitoring thus faces the challenge to comprehensively assess a multitude of contaminants and potential adverse effects. Effect-based methods have been suggested as complements to chemical analytical characterisation of complex pollution patterns. The regularly observed discrepancy between chemical and biological assessments of adverse effects due to contaminants in the field may be either due to unidentified contaminants or result from interactions of compounds in mixtures. Here, we present an interlaboratory study where individual compounds and their mixtures were investigated by extensive concentration-effect analysis using 19 different bioassays. The assay panel consisted of 5 whole organism assays measuring apical effects and 14 cell- and organism-based bioassays with more specific effect observations. Twelve organic water pollutants of diverse structure and unique known modes of action were studied individually and as mixtures mirroring exposure scenarios in freshwaters. We compared the observed mixture effects against component-based mixture effect predictions derived from additivity expectations (assumption of non-interaction). Most of the assays detected the mixture response of the active components as predicted even against a background of other inactive contaminants. When none of the mixture components showed any activity by themselves then the mixture also was without effects. The mixture effects observed using apical endpoints fell in the middle of a prediction window defined by the additivity predictions for concentration addition and independent action, reflecting well the diversity of the anticipated modes of action. In one case, an unexpectedly reduced solubility of one of the mixture components led to mixture responses that fell short of the predictions of both additivity mixture models. The majority of the specific cell- and organism

  15. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    Science.gov (United States)

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Linking in situ bioassays and population dynamics of macroinvertebrates to assess agricultural contamination in streams of the Argentine pampa.

    Science.gov (United States)

    Jergentz, S; Pessacq, P; Mugni, H; Bonetto, C; Schulz, R

    2004-10-01

    The two local crustacean species Hyalella curvispina and Macrobrachium borelli were chosen for assessment of agricultural contamination in two streams (Horqueta and Maguire) in the Argentine pampa. In parallel with in situ bioassays of both species, the population dynamics and the organismic drift of H. curvispina were investigated throughout the main period of insecticide application, from December 2001 to March 2002. In Maguire none of the current-use insecticides (chlorpyrifos, alpha-cypermethrin, and endosulfan) in question were detected throughout the sampling period. During 1-week intervals with no contamination by insecticides the survival rate of H. curvispina varied between 77 +/- 6% (+/- SE, n = 4) and 85 +/- 3%. In Horqueta during a week with a peak insecticide contamination of 64 microg/kg chlorpyrifos in the suspended particles, a mortality of 100% was observed in the in situ bioassays for both species, H. curvispina and M. borelli. At the same time, in Maguire H. curvispina showed reduced survival rates of 23 +/- 5% and 25 +/- 18% at the two sites, while the survival rate of M. borelli was 60 +/- 11% upstream and 93 +/- 5% downstream, below a wetland. During the period with 100% mortality of H. curvispina in Horqueta, the population density of this species decreased correspondingly, from 106 +/- 26 to 0 individuals/m(2). We conclude that in situ bioassays can be successfully linked to in-stream population dynamics for the same species and that this link is very useful for interpreting causal exposure-effect relationships.

  17. Estimating Prion Adsorption Capacity of Soil by BioAssay of Subtracted Infectivity from Complex Solutions (BASICS)

    Science.gov (United States)

    Wyckoff, A. Christy; Lockwood, Krista L.; Meyerett-Reid, Crystal; Michel, Brady A.; Bender, Heather; VerCauteren, Kurt C.; Zabel, Mark D.

    2013-01-01

    Prions, the infectious agent of scrapie, chronic wasting disease and other transmissible spongiform encephalopathies, are misfolded proteins that are highly stable and resistant to degradation. Prions are known to associate with clay and other soil components, enhancing their persistence and surprisingly, transmissibility. Currently, few detection and quantification methods exist for prions in soil, hindering an understanding of prion persistence and infectivity in the environment. Variability in apparent infectious titers of prions when bound to soil has complicated attempts to quantify the binding capacity of soil for prion infectivity. Here, we quantify the prion adsorption capacity of whole, sandy loam soil (SLS) typically found in CWD endemic areas in Colorado; and purified montmorillonite clay (Mte), previously shown to bind prions, by BioAssay of Subtracted Infectivity in Complex Solutions (BASICS). We incubated prion positive 10% brain homogenate from terminally sick mice infected with the Rocky Mountain Lab strain of mouse-adapted prions (RML) with 10% SLS or Mte. After 24 hours samples were centrifuged five minutes at 200×g and soil-free supernatant was intracerebrally inoculated into prion susceptible indicator mice. We used the number of days post inoculation to clinical disease to calculate the infectious titer remaining in the supernatant, which we subtracted from the starting titer to determine the infectious prion binding capacity of SLS and Mte. BASICS indicated SLS bound and removed ≥ 95% of infectivity. Mte bound and removed lethal doses (99.98%) of prions from inocula, effectively preventing disease in the mice. Our data reveal significant prion-binding capacity of soil and the utility of BASICS to estimate prion loads and investigate persistence and decomposition in the environment. Additionally, since Mte successfully rescued the mice from prion disease, Mte might be used for remediation and decontamination protocols. PMID:23484043

  18. Responses in sediment bioassays used in the Netherlands: can observed toxicity be explained by routinely monitored priority pollutants?

    NARCIS (Netherlands)

    Lahr, J.; Maas-Diepeveen, J.L.; Stuijfzand, S.C.; Leonards, P.E.G.; Drueke, J.M.; Luecker, S.; Espeldoorn, A.

    2003-01-01

    In order to identify the cause of toxicity in sediments and suspended matter, a large number of samples with different degrees of contamination was taken at various locations in The Netherlands. Standard acute bioassays were carried out with the bacterium Vibrio fischeri, the rotifer Brachionus

  19. Ionisation constants of radiopharmaceuticals by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Stylli, C.G.; Theobald, A.E.

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation.

  20. Ionisation constants of radiopharmaceuticals by HPLC

    International Nuclear Information System (INIS)

    Stylli, C.G.; Theobald, A.E.

    1986-01-01

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation. (author)