WorldWideScience

Sample records for motors repair techniques

  1. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  2. The optimization of electric motors repair techniques as a mean for electric energy saving; La optimizacion de las tecnicas de reparacion de motores electricos como un medio para ahorrar energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Zagal Leon, Juan Ruben [Fideicomiso para el Ahorro de Energia Electrica (FIDE), Mexico, D. F. (Mexico)

    1999-12-31

    This paper presents, in a very concise, which are the techniques to optimize the electric motors repair made by the Fideicomiso para el Ahorro de Energia Electrica (FIDE), the loss of efficiency that might exist after repairing an electric motor, as well as the procedures to perform an optimum reparation of the electric motors. Furthermore, some recommendations are given for the selection of an adequate rewinding shop to guarantee that the motor does not suffer efficiency losses after its repair. [Espanol] Este trabajo presenta, de manera muy concreta, cuales son las tecnicas para optimizar las tecnicas de reparacion de motores electricos realizado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE), el nivel de perdida de eficiencia que puede existir despues de reparar un motor electrico, asi como los procedimientos para realizar una optima reparacion en motores electricos. Asimismo, se proporcionan algunas recomendaciones para seleccionar un taller de reembobinado adecuado para garantizar que el motor no sufra perdidas de eficiencia despues de su reparacion.

  3. Mountain Plains Learning Experience Guide: Electric Motor Repair.

    Science.gov (United States)

    Ziller, T.

    This Electric Motor Repair Course is designed to provide the student with practical information for winding, repairing, and troubleshooting alternating current and direct current motors, and controllers. The course is comprised of eight units: (1) Electric Motor Fundamentals, (2) Rewinding, (3) Split-phase Induction Motors, (4) Capacitor Motors,…

  4. Radar rainfall image repair techniques

    Directory of Open Access Journals (Sweden)

    Stephen M. Wesson

    2004-01-01

    Full Text Available There are various quality problems associated with radar rainfall data viewed in images that include ground clutter, beam blocking and anomalous propagation, to name a few. To obtain the best rainfall estimate possible, techniques for removing ground clutter (non-meteorological echoes that influence radar data quality on 2-D radar rainfall image data sets are presented here. These techniques concentrate on repairing the images in both a computationally fast and accurate manner, and are nearest neighbour techniques of two sub-types: Individual Target and Border Tracing. The contaminated data is estimated through Kriging, considered the optimal technique for the spatial interpolation of Gaussian data, where the 'screening effect' that occurs with the Kriging weighting distribution around target points is exploited to ensure computational efficiency. Matrix rank reduction techniques in combination with Singular Value Decomposition (SVD are also suggested for finding an efficient solution to the Kriging Equations which can cope with near singular systems. Rainfall estimation at ground level from radar rainfall volume scan data is of interest and importance in earth bound applications such as hydrology and agriculture. As an extension of the above, Ordinary Kriging is applied to three-dimensional radar rainfall data to estimate rainfall rate at ground level. Keywords: ground clutter, data infilling, Ordinary Kriging, nearest neighbours, Singular Value Decomposition, border tracing, computation time, ground level rainfall estimation

  5. Quality electric motor repair: A guidebook for electric utilities

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, V.; Douglass, J.

    1995-08-01

    This guidebook provides utilities with a resource for better understanding and developing their roles in relation to electric motor repair shops and the industrial and commercial utility customers that use them. The guidebook includes information and tools that utilities can use to raise the quality of electric motor repair practices in their service territories.

  6. Arthroscopic Hip Labral Repair: The Iberian Suture Technique

    OpenAIRE

    Stubbs, Allston J.; Andersen, Jason S.; Mannava, Sandeep; Wooster, Benjamin M.; Howse, Elizabeth A.; Winter, S. Bradley

    2014-01-01

    Arthroscopic hip labral repair has beneficial short-term outcomes; however, debate exists regarding ideal surgical labral repair technique. This technical note presents an arthroscopic repair technique that uses intrasubstance labral suture passage to restore the chondrolabral interface. This “Iberian suture technique” allows for an anatomic repair while posing minimal risk of damage to the labral and chondral tissues.

  7. Laboratory testing of closure cap repair techniques

    International Nuclear Information System (INIS)

    Persoff, P.; Moridis, G.; Tuck, D.M.

    1996-10-01

    Landfill design requires a low permeability closure cap as well as a low permeability liner. The Savannah River Site, in South Carolina, has approximately 85 acres of mixed waste landfills covered with compacted kaolin clay. Maintaining low permeability of the clay cap requires both that the permeability of the compacted clay itself remain low and that the integrity of the barrier be maintained. Barrier breaches typically result from penetration by roots or animals, and especially cracks caused by uneven settling or desiccation. In this study, clay layers, 0.81 m in diameter and 7.6 cm thick, were compacted in 7 lysimeters to simulate closure caps. The hydraulic conductivity of each layer was measured, and the compacted clay layers (CCL's) were cracked by drying. Then various repair techniques were applied and the effectiveness of each repair was assessed by remeasuring the hydraulic conductivity. Finally the repaired CCL was again dried and measured to determine how the repair responded to the conditions that caused the original failure. For a full report of this investigation see Persoff et al. Six repair techniques have been tested, four of which involve the use of injectable barrier liquids colloidal silica (CS) and polysiloxane (PSX) described below: (I) covering the crack with a bentonite geosynthetic clay liner (GCL), (ii) recompaction of new kaolinite at STD+3 moisture content joined to existing kaolinite that had dried and shrunk, (iii) direct injection of colloidal silica to a crack, (iv) injection of colloidal silica (CS) to wells in an overlying sand layer, (v) direct injection of polysiloxane to a crack, and (vi), injection of polysiloxane (PSX) to wells in an overlying soil layer

  8. Qualification of electric motors class 1E for supply of motors and its repair

    International Nuclear Information System (INIS)

    Perez, E.; Gonzalez, J. J.; Fernandez, A.; Garcia, D.

    2005-01-01

    Different original suppliers of nuclear grade equipment have either disappeared or discontinued the manufacture of this kind equipment. Under this situation nuclear plants are experiencing difficulties when dealing with the substitution or maintenance of these equipment. Tecnatom and Cantarey have developed a new line of Class 1E qualified electric low voltage motors which can be used as an alternative to originally installed safety-related motors or for its repair and maintenance. (Author)

  9. An Overview of Corroded Pipe Repair Techniques Using Composite Materials

    OpenAIRE

    K. S. Lim; S. N. A. Azraai; N. M. Noor; N. Yahaya

    2015-01-01

    Polymeric composites are being increasingly used as repair material for repairing critical infrastructures such as building, bridge, pressure vessel, piping and pipeline. Technique in repairing damaged pipes is one of the major concerns of pipeline owners. Considerable researches have been carried out on the repair of corroded pipes using composite materials. This article attempts a short review of the subject matter to provide insight into various techniques used in repa...

  10. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  11. Training in the Motor Vehicle Repair and Sales Sector in Greece. Report for the FORCE Programme.

    Science.gov (United States)

    Papaionnou, Skevos; Patsatzis, N.

    A study listed and analyzed the vocational training and continuing training systems for staff in the motor vehicle repair and sales sector in Greece. Heavy taxation on motor vehicles led to difficulty in replacing vehicles that resulted in a very high demand for vehicle repairs, which, in conjunction with the ambiguous legislation governing the…

  12. Training in the Motor Vehicle Repair and Sales Sector. Report for the FORCE Programme. European Report.

    Science.gov (United States)

    Rauner, Felix; And Others

    Trends in training for employment in the motor vehicle repair and sales sectors in the 12 European Community (EC) countries were identified through a review of 12 national reports that were prepared by 16 research teams involved in an EC study on continuing training in the motor vehicle sales and repair sector. Special attention was paid to the…

  13. Rapid repair advisor for motor-operated valves

    International Nuclear Information System (INIS)

    Somsel, J.K.

    1991-01-01

    This paper reports on the initial proposed application for the Rapid Repair Advisor project for motor-operated valves (MOVs). The expected benefits from an MOV testing expert system depend on the purpose of the testing. Straight acceptance testing (post-maintenance and surveillance) could benefit from field verification of test validity. Troubleshooting of failed operators is seldom difficult. Intermittent problems are difficult to resolve suggesting that trace recording capabilities are needed. Predictive diagnosis places the most demands on the interpretive skills of the engineer. However, the limit to predictive capabilities seems to lie in the design of the MOV and the measurable parameters. Utilities are expected to require a knowledgeable MOV maintenance engineer to make decisions on MOV maintenance and operability. The economics of developing an expert system are comparable to improved training for the end-users

  14. Innovative Concrete Repairing Technique Using Post Tensioning Steel Straps

    Directory of Open Access Journals (Sweden)

    Ma Chau-Khun

    2017-01-01

    Full Text Available In this paper, innovative technique using low-cost recycled steel straps confinement to repair load-induced damaged high-strength concrete (HSC columns were studied. This paper explains the effects of repairing technique using post tensioning steel straps. A series of experimental test was carried out to investigate the stress-strain relationships of such concrete. A total of 6 HSC columns were compressed 50% of their ultimate strength, then repaired by using steel straps. The proposed repairing technique significantly improved the performance of damaged concrete columns, in both strength and ductility. It was evidenced from this study that the steel strapping confining technique is effective in repairing of damaged HSC columns but ensured reasonable operating costs.

  15. Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique.

    Science.gov (United States)

    Tocci, Stephen L; Tashjian, Robert Z; Leventhal, Evan; Spenciner, David B; Green, Andrew; Fleming, Braden C

    2008-01-01

    This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.

  16. Factors Influencing Choice of Inguinal Hernia Repair Technique ...

    African Journals Online (AJOL)

    Background: Inguinal hernia repair surgery is one of the most frequently performed surgical procedures worldwide. This study sought to highlight factors that may influence decisions concerning inguinal hernia repair techniques. Methods: This descriptive crosssectional study was carried out in September 2014 among ...

  17. Factors Influencing Choice of Inguinal Hernia Repair Technique

    African Journals Online (AJOL)

    This study sought to highlight factors that may influence ... Experienced peers play a major role in training on the various repair ... Reasons influencing choice of repair technique include training ... (after appendectomy) accounting for 10 to 15% of all surgical ..... in medical school [as undergraduate students or as residents].

  18. a technique to repair peripheral nerve injury

    African Journals Online (AJOL)

    attached nerve does occi.rr, and functional recovery (sensory and motor) has been demonstrated. ..... Brachial plexus. Upper trunk to lower. 19 Nov 1998 ... Fractured. 13 Mar 1998 Mid shaft hiunerus Radial nerve to. 14 Mar 1999 humerus cut.

  19. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  20. Recovering full repair costs of INDOT infrastructure damaged by motor vehicle crashes.

    Science.gov (United States)

    2011-01-01

    There are approximately 4,000 instances per year where state property located along Indiana Department of Transportation : (INDOT) maintained right-of-way needs to be replaced or repaired due to motor vehicle crashes. INDOT incurs significant financi...

  1. Recovering full repair costs of INDOT infrastructure damaged by motor vehicle crashes : [technical summary].

    Science.gov (United States)

    2011-09-01

    There are approximately 4,000 instances per year that require infrastructure located along right-of-way maintained by the Indiana Department of Transportation (INDOT) to be replaced or repaired due to motor vehicle crashes. This infrastructure includ...

  2. The electric motor handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Feltham, P. (eds.)

    2004-05-01

    This handbook outlines the important role that electric motors play in modern society. It covers the field of motor applications from various motor types to their use and repair. It also presents practical applications of electric motors and methods on motor efficiency. More than half of all electricity generated, and 75 per cent of all industrial electricity consumption is consumed by electric motors. Electrical personnel must be aware of all factors involved in electric motors in order to choose and apply the appropriate size of electric motor. These factors include efficiency, sizing and proper application. The efficient use and maximum life expectancy of electric motors depends on proper motor protection, control and maintenance. This handbook includes articles from leading experts on electric motors in modern electrical systems. The content includes: design considerations; proper electric motor sizing techniques; optimal electric motor application; electric motor protection technology; electric motor control principles; electric motor maintenance and troubleshooting; induction electric motors; electric motor bearing currents; electric motor bearing lubrication; electromagnetism; electric motor enclosures; electric motor testing; electric motor repair; DC electric motor; electric motor starters; electric motor brushes; industrial electric motors; electric motor diagrams; AC electric motors; electric motor wiring; electric motor service; electric motor rewinding; electric motor winding; diagram of electric motor wiring; electric motor kit; and, troubleshooting electric motors. A directory of motor manufacturers and suppliers was also included. refs., tabs., figs.

  3. Advanced inspection and repair techniques for primary side components

    International Nuclear Information System (INIS)

    Elm, Ralph

    1998-01-01

    The availability of nuclear power plant mainly depends on the components of the Nuclear Steam Supply System (NSSS) such as reactor pressure vessel, core internals and steam generators. The last decade has been characterized by intensive inspection and repair work on PWR steam generators. In the future, it can be expected, that the inspection of the reactor pressure vessel and the inspection and repair of its internals, in both PWR and BWR will be one of the challenges for the nuclear community. Due to this challenge, new, advanced inspection and repair techniques for the vital primary side components have been developed and applied, taking into account such issues as: use of reliable and fast inspection methods, repair of affected components instead of costly replacement, reduction of outage time compared to conventional methods, minimized radiation exposure, acceptable costs. This paper reflects on advanced inspection and repair techniques such as: Baffle Former Bolt inspection and replacement, Barrel Former Bolt inspection and replacement, Mechanized UT and visual inspection of reactor pressure vessels, Steam Generator repair by advanced sleeving technology. The techniques described have been successfully applied in nuclear power plants and improved the operation performance of the components and the NPP. (author). 6 figs

  4. [Progress of Masquelet technique to repair bone defect].

    Science.gov (United States)

    Yin, Qudong; Sun, Zhenzhong; Gu, Sanjun

    2013-10-01

    To summarize the progress of Masquelet technique to repair bone defect. The recent literature concerning the application of Masquelet technique to repair bone defect was extensively reviewed and summarized. Masquelet technique involves a two-step procedure. First, bone cement is used to fill the bone defect after a thorough debridement, and an induced membrane structure surrounding the spacer formed; then the bone cement is removed after 6-8 weeks, and rich cancellous bone is implanted into the induced membrane. Massive cortical bone defect is repaired by new bone forming and consolidation. Experiments show that the induced membrane has vascular system and is also rich in vascular endothelial growth factor, transforming growth factor beta1, bone morphogenetic protein 2, and bone progenitor cells, so it has osteoinductive property; satisfactory results have been achieved in clinical application of almost all parts of defects, various types of bone defect and massive defect up to 25 cm long. Compared with other repair methods, Masquelet technique has the advantages of reliable effect, easy to operate, few complications, low requirements for recipient site, and wide application. Masquelet technique is an effective method to repair bone defect and is suitable for various types of bone defect, especially for bone defects caused by infection and tumor resection.

  5. Advanced Inspection and Repair Welding Techniques for SCC Countermeasures

    International Nuclear Information System (INIS)

    Takagi, T.; Nishimoto, K.; Uchimoto, T.

    2012-01-01

    Feasibility studies of advanced inspection and repair welding techniques were conducted in the framework of the Nuclear and Industry Safety Agency of Japan (NISA) project on the enhancement of ageing management and maintenance of NPPs. In this paper, features of NDE methods investigated in the projects, main results of research activities and prospect of nickel based alloy weld inspection are discussed. We also make a review for the integrity and reliability evaluation techniques for repair welding of ageing plants which were intensively investigated in view of regulatory criteria, in NISA project. (author)

  6. Motor of Lift RSG-GAS Performance Analysis after Repair

    International Nuclear Information System (INIS)

    Asep-Saepuloh; Yayan-Andriyanto; Yuyut-Suraniyanto

    2006-01-01

    The out of order an equipment is ordinary natural process happened, above all the equipment be used continually with very old time, as for as out of order can be resulted from kinds of cause. Lift motor out of order can be result by motor is broken or happened the body shorten then affected do not function it the lift, so until done rewinding process. The rewinding is furl to repeat at motor coils. Motor of Lift represent main activator machine turning around shares pulley. Lift Motor will work if there is called in normal operation condition or the moment manual switch if done maintenance. Motor used at lift is motor three phases with two speeds that is low speed and high speed. Rewinding process must be done removed the motor from Lift machine and have to be done by professional workshop. In during function test take place, temperature at coil reach 70 o C (exceeding boundary permitted). After done installation addition thermal at motor coil hence his temperature become normal that is only reach 50 o C. (author)

  7. A very simple technique to repair Grynfeltt-Lesshaft hernia.

    Science.gov (United States)

    Solaini, Leonardo; di Francesco, F; Gourgiotis, S; Solaini, Luciano

    2010-08-01

    A very simple technique to repair a superior lumbar hernia is described. The location of this type of hernia, also known as the Grynfeltt-Lesshaft hernia, is defined by a triangle placed in the lumbar region. An unusual case of a 67-year-old woman with a superior lumbar hernia is reported. The diagnosis was made by physical examination. The defect of the posterior abdominal wall was repaired with a polypropylene dart mesh. The patient had no evidence of recurrence at 11 months follow up. The surgical approach described in this paper is simple and easy to perform, and its result is comparable with other techniques that are much more sophisticated. No cases on the use of dart mesh to repair Grynfeltt-Lesshaft hernia have been reported by surgical journals indexed in PubMed.

  8. The corset platysma repair: a technique revisited.

    Science.gov (United States)

    Jacob, Carolyn I; Kaminer, Michael S

    2002-03-01

    Platysma banding along with excess submental adipose tissue and sagging skin can lead to an aged appearance. Several methods for improving neck and submental contours exist, including neck liposuction, bilateral platysma plication, midline platysma plication with transection of distal fibers, necklift with skin excision, and botulinum toxin injection for platysma relaxation. With the current interest in minimally invasive procedures, surgeons and patients are searching for techniques that produce maximal improvement with minimal intervention. To present a modified technique for maximizing neck contouring, discuss possible complications of the procedure, and describe appropriate candidates for the corset platysmaplasty. We performed a retrospective analysis of 10 consecutive patients who underwent neck liposuction with concomitant corset platysmaplasty at our institution. All 10 patients achieved good to excellent submental and jawline contouring, determined by both physician and patient assessment, with no visible platysma banding at 6 months follow-up. No major complications were noted. Use of corset platysmaplasty is a safe and effective method for neck rejuvenation. This variation of platysmaplasty can be used in conjunction with neck liposuction to maximize jawline and neck contour enhancement.

  9. Exploration Challenges: Transferring Ground Repair Techniques to Space Flight Application

    Science.gov (United States)

    McLemore, Carole A.; Kennedy, James P.; Rose, Frederick A.; Evans, Brian W.

    2007-01-01

    Fulfilling NASA's Vision for Space Exploration will demand an extended presence in space at distances from our home planet that exceed our current experience in space logistics and maintenance. The ability to perform repairs in lieu of the customary Orbital Replacement Unit (ORU) process where a faulty part is replaced will be elevated from contingency to routine to sustain operations. The use and cost effectiveness of field repairs for ground based operations in industry and the military have advanced with the development of technology in new materials, new repair techniques and new equipment. The unique environments, accessibility constraints and Extra Vehicular Activity (EVA) issues of space operations will require extensive assessment and evolution of these technologies to provide an equivalent and expected level of assurance to mission success. Challenges include the necessity of changes in design philosophy and policy, extremes in thermal cycling, disruptive forces (such as static charge and wind entrainment) on developed methods for control of materials, dramatically increased volatility of chemicals for cleaning and other compounds due to extremely low pressures, the limits imposed on dexterity and maneuverability by current EVA equipment and practices, and the necessity of unique verification methodology. This paper describes these challenges in and discusses the effects on the established ground techniques for repair. The paper also describes the leading repair methodology candidates and their beneficial attributes for resolving these issues with the evolution of technology.

  10. Gravity Compensation Technique Uses Small dc Motor

    Science.gov (United States)

    Hollow, Richard

    1988-01-01

    Small dc servomotor powered by simple constant-current source and with suitable gearing used to cancel effect of gravity upon load. Lead-screw positioning system has load counterbalanced by small supplementary motor powered by constant current source. Motor lighter and more compact alternative to counterbalance. Used in variety of mechanical systems where load positioned or accelerated in vertical plane.

  11. [Plug-technique for umbilical hernia repair in the adult].

    Science.gov (United States)

    Brancato, G; Privitera, A; Gandolfo, L; Donati, M; Caglià, P

    2002-02-01

    Umbilical hernia represents 6% of all abdominal wall hernias in the adult. Surgical repair should always be carried out due to possible occurrence of complications. Aim of this paper is to evaluate the efficacy of the plug-technique. From October 1995 to April 2000, the authors performed 21 operations for acquired umbilical hernia with a defect smaller than 4 cm. Local anesthesia was used and a light intravenous sedation added in particularly anxious patients. The repair was achieved by insertion of a polypropylene dart plug sutured to the margins of the hernial defect. All patients were up and about straightaway and were discharged within 24 hours of surgery. Postoperative pain was mild and required hospital analgesia in only 19% of cases and domiciliary analgesia in 24%. During a follow-up ranging from 6 to 60 months (mean 30), only one recurrence has been recorded. This tension-free technique allows immediate rehabilitation, with few complications and a low recurrence rate.

  12. Damage Tolerant Repair Techniques for Pressurized Aircraft Fuselages

    Science.gov (United States)

    1994-01-01

    RepoW Techniques for Prwurized Aircraft AXWdOg 4.9 Summary and Conclusions The basics of adhesive bonded repairs for aluminum aircraft fuselages have... of cruise altitude and bending stresses in the plate at the tip of one-sided reinforcements (chapter 5). The expanded Rose model was transformed into a...DEPARTMEN1 OF THE AIR FORCE AGENCY REPORT NUMBER AFIT/CI 2950 P STREET WRIGHT-PATTERSON AFB OH 45433-7765 11. SUPPLEMENTARY NOTES Usa. DISTRUISUIOII

  13. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    Science.gov (United States)

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  14. ANALYSIS OF RELATIONS BETWEEN JUDO TECHNIQUES AND SPECIFIC MOTOR ABILITIES

    Directory of Open Access Journals (Sweden)

    Patrik Drid

    2006-06-01

    Full Text Available Specific physical preparation affects the development of motor abilities required for execution of specific movements in judo. When selecting proper specific exercises for judo for a target motor ability, it is necessary to precede it with the study of the structure of specific judo techniques and activities of individual muscle groups engaged for execution of the technique. On the basis of this, one can understand which muscles are most engaged during realization of individual techniques, which serves as a standpoint for selection of a particular complex of specific exercises to produce the highest effects. In addition to the development of particular muscle groups, the means of specific preparation will take effect on the development of those motor abilities which are evaluated as the indispensable for the development of particular qualities which are characteristic for judo. This paper analyses the relationship between judo techniques field and specific motor abilities.

  15. Evolution of Autologous Chondrocyte Repair and Comparison to Other Cartilage Repair Techniques

    Directory of Open Access Journals (Sweden)

    Ashvin K. Dewan

    2014-01-01

    Full Text Available Articular cartilage defects have been addressed using microfracture, abrasion chondroplasty, or osteochondral grafting, but these strategies do not generate tissue that adequately recapitulates native cartilage. During the past 25 years, promising new strategies using assorted scaffolds and cell sources to induce chondrocyte expansion have emerged. We reviewed the evolution of autologous chondrocyte implantation and compared it to other cartilage repair techniques. Methods. We searched PubMed from 1949 to 2014 for the keywords “autologous chondrocyte implantation” (ACI and “cartilage repair” in clinical trials, meta-analyses, and review articles. We analyzed these articles, their bibliographies, our experience, and cartilage regeneration textbooks. Results. Microfracture, abrasion chondroplasty, osteochondral grafting, ACI, and autologous matrix-induced chondrogenesis are distinguishable by cell source (including chondrocytes and stem cells and associated scaffolds (natural or synthetic, hydrogels or membranes. ACI seems to be as good as, if not better than, microfracture for repairing large chondral defects in a young patient’s knee as evaluated by multiple clinical indices and the quality of regenerated tissue. Conclusion. Although there is not enough evidence to determine the best repair technique, ACI is the most established cell-based treatment for full-thickness chondral defects in young patients.

  16. Determining flexor-tendon repair techniques via soft computing

    Science.gov (United States)

    Johnson, M.; Firoozbakhsh, K.; Moniem, M.; Jamshidi, M.

    2001-01-01

    An SC-based multi-objective decision-making method for determining the optimal flexor-tendon repair technique from experimental and clinical survey data, and with variable circumstances, was presented. Results were compared with those from the Taguchi method. Using the Taguchi method results in the need to perform ad-hoc decisions when the outcomes for individual objectives are contradictory to a particular preference or circumstance, whereas the SC-based multi-objective technique provides a rigorous straightforward computational process in which changing preferences and importance of differing objectives are easily accommodated. Also, adding more objectives is straightforward and easily accomplished. The use of fuzzy-set representations of information categories provides insight into their performance throughout the range of their universe of discourse. The ability of the technique to provide a "best" medical decision given a particular physician, hospital, patient, situation, and other criteria was also demonstrated.

  17. No patch technique for complete atrioventricular canal repair.

    Science.gov (United States)

    Aramendi, José Ignacio; Rodriguez, Miguel Angel; Luis, Teresa; Voces, Roberto

    2006-08-01

    We describe our initial experience with a new technique, consisting in direct closure of the ventricular septal defect component of the AV canal, by directly attaching the common bridging leaflets to the crest of the ventricular septum with interrupted sutures. After closure of the cleft, the ostium primum defect was closed with a running suture suturing the border of the septum primum to the newly created AV valve annulus. Three patients were operated upon. There was no mortality. Mean ischemic time was 39 min and mean pump time 77 min. All patients remained in sinus rhythm. At follow-up only trivial or mild mitral regurgitation was observed. This new technique permits the repair of complete AV canal without the need for any patch. It is fast, simple and reproducible.

  18. Training in the Motor Vehicle Repair and Sales Sector in the Netherlands. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Warmerdam, John; And Others

    Training in the motor vehicle repair and sales sector in the Netherlands was examined in a study that included the following approaches: review of the sector's structure/characteristics, institutional and social context, employment practices, changing conditions, and available education and training; in-depth case studies of four auto repair shops…

  19. A Review of the Labor Market, Manpower Characteristics and Training of Motor Vehicle Repair Personnel. Final Report.

    Science.gov (United States)

    McCutcheon, R. W.; And Others

    To determine whether current automotive mechanic training programs provide adequate exposure to the knowledge and skills needed to properly service and repair motor vehicles, data were gathered on the tasks, service and repair establishments, job market, labor force, and training programs. Primary sources of data are reports prepared by various…

  20. Cyclic Testing of the 6-Strand Tang and Modified Lim-Tsai Flexor Tendon Repair Techniques.

    Science.gov (United States)

    Kang, Gavrielle Hui-Ying; Wong, Yoke-Rung; Lim, Rebecca Qian-Ru; Loke, Austin Mun-Kitt; Tay, Shian-Chao

    2018-03-01

    In this study, we compared the Tang repair technique with the 6-strand modified Lim-Tsai repair technique under cyclic testing conditions. Twenty fresh-frozen porcine flexor tendons were randomized into 2 groups for repair with either the modified Lim-Tsai or the Tang technique using Supramid 4-0 core sutures and Ethilon 6-0 epitendinous running suture. The repaired tendons were subjected to 2 stage cyclic loading. The survival rate and gap formation at the repair site were recorded. Tendons repaired by the Tang technique achieved an 80% survival rate. None of the modified Lim-Tsai repairs survived. The mean gap formed at the end of 1000 cycles was 1.09 mm in the Tang repairs compared with 4.15 mm in the modified Lim-Tsai repairs. The Tang repair is biomechanically stronger than the modified Lim-Tsai repair under cyclic loading. The Tang repair technique may exhibit a higher tolerance for active mobilization after surgery with less propensity for gap formation. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Fundamental study on repairing technique for cracked or damaged parts of structures by cold gas dynamic spray technique

    International Nuclear Information System (INIS)

    Ogawa, Kazuhiro; Amao, Satoshi; Ichikawa, Yuji; Shoji, Tetsuo

    2008-01-01

    This study proposes an innovative technique for repairing of cracked or damaged parts of structures, such as nuclear or thermal power plants, by means of cold gas dynamic spray (CS) technique. In the case of generation of cracks etc. in the structure, the cracks can be repaired by welding. However, the welding spends considerable time on repair, and also needs special skills. The CS technique is known as a new technique not only for coatings but also for thick depositions. It has many advantages, i.e. dense deposition, high deposition rate and low oxidation. Therefore, it has a possibility to apply the CS technique instead of welding to repair the cracks etc. In this study, the cold gas dynamic spray technique as a new repairing technique for some structures is introduced. (author)

  2. Repair and tissue engineering techniques for articular cartilage.

    Science.gov (United States)

    Makris, Eleftherios A; Gomoll, Andreas H; Malizos, Konstantinos N; Hu, Jerry C; Athanasiou, Kyriacos A

    2015-01-01

    Chondral and osteochondral lesions due to injury or other pathology commonly result in the development of osteoarthritis, eventually leading to progressive total joint destruction. Although current progress suggests that biologic agents can delay the advancement of deterioration, such drugs are incapable of promoting tissue restoration. The limited ability of articular cartilage to regenerate renders joint arthroplasty an unavoidable surgical intervention. This Review describes current, widely used clinical repair techniques for resurfacing articular cartilage defects; short-term and long-term clinical outcomes of these techniques are discussed. Also reviewed is a developmental pipeline of acellular and cellular regenerative products and techniques that could revolutionize joint care over the next decade by promoting the development of functional articular cartilage. Acellular products typically consist of collagen or hyaluronic-acid-based materials, whereas cellular techniques use either primary cells or stem cells, with or without scaffolds. Central to these efforts is the prominent role that tissue engineering has in translating biological technology into clinical products; therefore, concomitant regulatory processes are also discussed.

  3. Qualification of electric motors class 1E for supply of motors and its repair; Calificacion de motores electricos clase 1E para el suministro de motores alternativos a los orginales y su reparacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez, E.; Gonzalez, J. J.; Fernandez, A.; Garcia, D.

    2005-07-01

    Different original suppliers of nuclear grade equipment have either disappeared or discontinued the manufacture of this kind equipment. Under this situation nuclear plants are experiencing difficulties when dealing with the substitution or maintenance of these equipment. Tecnatom and Cantarey have developed a new line of Class 1E qualified electric low voltage motors which can be used as an alternative to originally installed safety-related motors or for its repair and maintenance. (Author)

  4. Improvement of AC motor reliability from technique standardization

    International Nuclear Information System (INIS)

    Muniz, P.R.; Faria, M.D.R.; Mendes, M.P.; Silva, J.N.; Dos Santos, J.D.

    2005-01-01

    The purpose of this paper is to explain the increase of reliability of motors serviced in the Electrical Maintenance Shop of Companhia Siderurgica de Tubarao by standardization of the technique based on Brazilian and International Standards, manufacturer's recommendations and the experience of the maintenance staff. (author)

  5. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique.

    Science.gov (United States)

    Park, Maxwell C; Tibone, James E; ElAttrache, Neal S; Ahmad, Christopher S; Jun, Bong-Jae; Lee, Thay Q

    2007-01-01

    We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of 1 mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for all cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.

  6. A Barbed Suture Repair For Flexor Tendons: A Novel Technique With No Exposed Barbs

    Directory of Open Access Journals (Sweden)

    Cormac W. Joyce, MB BCh

    2014-10-01

    Conclusions: We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  7. Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique.

    Science.gov (United States)

    Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael

    2018-04-24

    Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.

  8. Direct repair of lumbar spondylolysis by Buck′s technique

    Directory of Open Access Journals (Sweden)

    S Rajasekaran

    2011-01-01

    encountered in the perioperative or postoperative period. Conclusions: In carefully selected patients, direct repair of the pars defect by the Buck′s technique of internal fixation and bone grafting was a safe and effective alternative to fusion in younger patients with symptomatic spondylolysis, without associated spondylolisthesis, who failed conservative management.

  9. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    Directory of Open Access Journals (Sweden)

    Natalia Perussi Biscola

    2016-01-01

    Full Text Available Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons.

  10. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

    OpenAIRE

    Mook, William R.; Greenspoon, Joshua A.; Millett, Peter J.

    2016-01-01

    Background: Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. Methods: The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construc...

  11. Hypospadias repair with the glanular-frenular collar (GFC) technique.

    Science.gov (United States)

    Özbey, Hüseyin; Etker, Şeref

    2017-02-01

    In the normal human penis, the glans wings merge in the midline ventrally, but are separated by the 'septum glandis' in conjunction with the frenulum. The frenulum is also included in the formation of the distal (glanular and subcoronal) urethra, which has a special part known as the 'fossa navicularis'. This has inspired a hypospadias repair technique that simulates the development of the glanular and subcoronal urethra, which can be incorporated into the repair of all cases of hypospadias. A total of 121 patients with varying degrees of hypospadias underwent surgery with the described technique: a Y-V plasty was used to dissect the inner foreskin, in a fashion that allowed for its ventral mobilization as a frenular mucosal collar. After tubularization of the proximal urethra, a partial spongioplasty was performed that extended up to the subcoronal level. The glans wings were approximated only at their outermost convexities, with a couple of subepithelial sutures, leaving a slit for the meatus. The cleft-like area between the split wings of the glans penis was filled with the terminal ends of the spongiosum and the dartos of the mucosal collar, which converged to form a septum and a neo-frenulum (glanular-frenular collar, GFC). The midline skin closure of the ventral collar and the circumferential foreskin closure was completed as usual. At a mean follow-up of 10 months, two patients developed urethral fistula (2%), six had meatal stenosis (5%), and two had glans dehiscence (2%) that resulted in meatal retraction. Overall, patients had a cosmetically satisfying appearance (Figure). Forty-one received secondary circumcision; the parents of 80 (66%) patients were satisfied with the final foreskin appearance obtained with this method. The split wings of the glans penis or so-called ventral cleft between the glans wings that accommodate the frenulum is part of normal anatomy. Hence, in hypospadias surgery, the approximated glans wings should allow for ventral support

  12. Robotic Inguinal Hernia Repair: Technique and Early Experience.

    Science.gov (United States)

    Arcerito, Massimo; Changchien, Eric; Bernal, Oscar; Konkoly-Thege, Adam; Moon, John

    2016-10-01

    Laparoscopic inguinal hernia repair has been shown to have multiple advantages compared with open repair such as less postoperative pain and earlier resume of daily activities with a comparable recurrence rate. We speculate robotic inguinal hernia repair may yield equivalent benefits, while providing the surgeon added dexterity. One hundred consecutive robotic inguinal hernia repairs with mesh were performed with a mean age of 56 years (25-96). Fifty-six unilateral hernias and 22 bilateral hernias were repaired amongst 62 males and 16 females. Polypropylene mesh was used for reconstruction. All but, two patients were completed robotically. Mean operative time was 52 minutes per hernia repair (45-67). Five patients were admitted overnight based on their advanced age. Regular diet was resumed immediately. Postoperative pain was minimal and regular activity was achieved after an average of four days. One patient recurred after three months in our earlier experience and he was repaired robotically. Mean follow-up time was 12 months. These data, compared with laparoscopic approach, suggest similar recurrence rates and postoperative pain. We believe comparative studies with laparoscopic approach need to be performed to assess the role robotic surgery has in the treatment of inguinal hernia repair.

  13. Repair technique for steam generator tubes using electroforming

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992{delta}1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10{delta}400{mu}m makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties.

  14. Repair technique for steam generator tubes using electroforming

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jeong, Hyun Kyu; Seo, Moon Hong

    2001-07-01

    Pickering B CANDU Unit 5 had experienced leakage at sleeve/tube joint due to severe and local pitting in 1992δ1993. One year later, OHT developed electrosleeving techniques for steam generator tube repair which was applied at Pickering B CANDU Unit 5, Oconee Unit 1 and Callaway in 1994, 1995 and 1999 respectively. In the results of electrosleeved tube test, electrosleeve materials were stronger than mother tubes in mechanical properties and corrosion resistance under design criteria. Two analytical models were originally developed for estimating the failure temperature under severe accident transients. Electrosleeve, a structural layer of fine grained nickel is electroformed onto the strike by circulating an aqueous solution of Ni sulfate or sulfamate with NiCO3. The patents published by FTI said that the electrolyte for electroforming the structural layer contains a pinning agent to inhibit growth of metal grains in the electroformed layer. The pinning agent contains phosphoric, phosphorous acid, molybdenum. In localization of electrosleeving, there are some problems like as 1)low plating rate, 2)high residual stress, 3)alloy composition, 4)low material properties at high temperature. Ni-Fe plating exhibit anomalous codeposition; that is less noble metal, Fe, deposits preferentially to the more noble metal, Ni. Ductility decrease and residual stress increase with increase of Fe content in plate layer. Addition of particle size of 10δ400μm makes residual stress compressive in plate layer. Composite plating show excellent high temperature properties

  15. Imaging techniques for the assessment of fracture repair.

    Science.gov (United States)

    Augat, P; Morgan, E F; Lujan, T J; MacGillivray, T J; Cheung, W H

    2014-06-01

    Imaging of a healing fracture provides a non-invasive and often instructive reproduction of the fracture repair progress and the healing status of bone. However, the interpretation of this reproduction is often qualitative and provides only an indirect and surrogate measure of the mechanical stability of the healing fracture. Refinements of the available imaging techniques have been suggested to more accurately determine the healing status of bone. Plain radiographs provide the ability to determine the degree of bridging of the fracture gap and to quantify the amount of periosteal callus formation. Absorptiometric measures including dual X-ray absorptiometry and computed tomography provide quantitative information on the amount and the density of newly formed bone around the site of the fracture. To include the effect of spatial distribution of newly formed bone, finite element models of healing fracture can be employed to estimate its load bearing capacity. Ultrasound technology not only avoids radiation doses to the patients but also provides the ability to additionally measure vascularity in the surrounding soft tissue of the fracture and in the fracture itself. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Anatomic deltoid ligament repair with anchor-to-post suture reinforcement: technique tip.

    Science.gov (United States)

    Lack, William; Phisitkul, Phinit; Femino, John E

    2012-01-01

    The deltoid ligament is the primary ligamentous stabilizer of the ankle joint. Both superficial and deep components of the ligament can be disrupted with a rotational ankle fracture, chronic ankle instability, or in late stage adult acquired flatfoot deformity. The role of deltoid ligament repair in these conditions has been limited and its contribution to arthritis is largely unknown. Neglect of the deltoid ligament in the treatment of ankle injuries may be due to difficulties in diagnosis and lack of an effective method for repair. Most acute repair techniques address the superficial deltoid ligament with direct end-to-end repair, fixation through bone tunnels, or suture anchor repair of avulsion injuries. Deep deltoid ligament repair has been described using direct end-to-end repair with sutures, as well as by autograft and allograft tendon reconstruction utilizing various techniques. Newer tenodesis techniques have been described for late reconstruction of both deep and superficial components in patients with stage 4 adult acquired flatfoot deformity. We describe a technique that provides anatomic ligament-to-bone repair of the superficial and deep bundles of the deltoid ligament while reducing the talus toward the medial malleolar facet of the tibiotalar joint with anchor-to-post reinforcement of the ligamentous repair. This technique may protect and allow the horizontally oriented fibers of the deep deltoid ligament to heal with the appropriate resting length while providing immediate stability of the construct.

  17. A barbed suture repair for flexor tendons: a novel technique with no exposed barbs.

    Science.gov (United States)

    Joyce, Cormac W; Sugrue, Conor; Chan, Jeffrey C; Delgado, Luis; Zeugolis, Dimitrios; Carroll, Seam M; Kelly, Jack L

    2014-10-01

    Barbed suture technology has shown promise in flexor tendon repairs, as there is an even distribution of load and the need for a knot is eliminated. We propose that a quick and simple, novel, barbed technique without any exposed barbs on the tendon surface has comparable strength and a smaller cross-sectional area at the repair site than traditional methods of repair. Forty porcine flexor tendons were randomized to polybutester 4-strand barbed repair or to 4-strand Adelaide monofilament repair. The cross-sectional area was measured before and after repair. Biomechanical testing was carried out and 2-mm gap formation force, ultimate strength of repair, and method of failure were recorded. The mean ultimate strength of the barbed repairs was 54.51 ± 17.9 while that of the Adelaide repairs was 53.17 ± 16.35. The mean 2-mm gap formation force for the barbed group was 44.71 ± 17.86 whereas that of the Adelaide group was 20.25 ± 4.99. The postrepair percentage change in cross-sectional area at the repair site for the Adelaide group and barbed group was 12.0 ± 2.3 and 4.6 ± 2.8, respectively. We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  18. Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique.

    Science.gov (United States)

    Mook, William R; Greenspoon, Joshua A; Millett, Peter J

    2016-01-01

    Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. The preferred technique for rotator cuff repair of the senior author was reviewed and described in a step by step fashion. The final construct is a knotless double row transosseous equivalent construct. The described technique includes the advantages of a double-row construct while also offering self reinforcement, decreased risk of suture cut through, decreased risk of medial row overtensioning and tissue strangulation, improved vascularity, the efficiency of a knotless system, and no increased risk for subacromial impingement from the burden of suture knots. Arthroscopic knotless double row rotator cuff repair is a safe and effective method to repair rotator cuff tears.

  19. Repair-oriented classification of aortic insufficiency: impact on surgical techniques and clinical outcomes.

    Science.gov (United States)

    Boodhwani, Munir; de Kerchove, Laurent; Glineur, David; Poncelet, Alain; Rubay, Jean; Astarci, Parla; Verhelst, Robert; Noirhomme, Philippe; El Khoury, Gébrine

    2009-02-01

    Valve repair for aortic insufficiency requires a tailored surgical approach determined by the leaflet and aortic disease. Over the past decade, we have developed a functional classification of AI, which guides repair strategy and can predict outcome. In this study, we analyze our experience with a systematic approach to aortic valve repair. From 1996 to 2007, 264 patients underwent elective aortic valve repair for aortic insufficiency (mean age - 54 +/- 16 years; 79% male). AV was tricuspid in 171 patients bicuspid in 90 and quadricuspid in 3. One hundred fifty three patients had type I dysfunction (aortic dilatation), 134 had type II (cusp prolapse), and 40 had type III (restrictive). Thirty six percent (96/264) of the patients had more than one identified mechanism. In-hospital mortality was 1.1% (3/264). Six patients experienced early repair failure; 3 underwent re-repair. Functional classification predicted the necessary repair techniques in 82-100% of patients, with adjunctive techniques being employed in up to 35% of patients. Mid-term follow up (median [interquartile range]: 47 [29-73] months) revealed a late mortality rate of 4.2% (11/261, 10 cardiac). Five year overall survival was 95 +/- 3%. Ten patients underwent aortic valve reoperation (1 re-repair). Freedoms from recurrent Al (>2+) and from AV reoperation at 5 years was 88 +/- 3% and 92 +/- 4% respectively and patients with type I (82 +/- 9%; 93 +/- 5%) or II (95 +/- 5%; 94 +/- 6%) had better outcomes compared to type III (76 +/- 17%; 84 +/- 13%). Aortic valve repair is an acceptable therapeutic option for patients with aortic insufficiency. This functional classification allows a systematic approach to the repair of Al and can help to predict the surgical techniques required as well as the durability of repair. Restrictive cusp motion (type III), due to fibrosis or calcification, is an important predictor for recurrent Al following AV repair.

  20. Training in the Motor Vehicle Repair and Sales Sector in Germany. Report of the FORCE Programme. First Edition.

    Science.gov (United States)

    Lichte, Rainer; And Others

    Training in the motor vehicle repair and sales sector in Germany was examined in a study that included the following approaches: review of the sector's structure/characteristics, institutional and social context, employment practices/trends, changes in the type of work and employment/training requirements, and available initial and continuing…

  1. Training in the Motor Vehicle Repair and Sales Sector in Italy. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Volonta, Marco

    An international team of researchers studied the following aspects of training in Italy's motor vehicle repair and sales sector: structure and characteristics; institutional and social context; relationship to Italy's overall labor market; changing structural, economic, and organizational conditions; and training and recruitment and relationship…

  2. Training in the Motor Vehicle Repair and Sales Sector in Denmark. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Knoblauch, Jan; And Others

    Training in Denmark's motor vehicle repair and sales sector was examined in a study that included the following approaches: review of the sector's structure/characteristics, institutional/social context, changing conditions and their implications for skill requirements and training, and available initial and continuing vocational education and…

  3. Training in the Motor Vehicle Repair and Sales Sector in the United Kingdom. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Rhys, Garel

    An international team of researchers studied the following aspects of training in the United Kingdom's motor vehicle repair and sales sector: structure and characteristics; institutional and social context; relationship to the labor market; changing structural, economic, and organizational conditions; and training/recruitment and relationship to…

  4. Training in the Motor Vehicle Repair and Sales Sector in Belgium. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Denys, Jan; And Others

    An international team of researchers studied the following aspects of training in Belgium's motor vehicle repair and sales sector: structure and characteristics; institutional and social context; relationship to Belgium's overall labor market; changing structural, economic, and organizational conditions; and training and recruitment and…

  5. Short Summary European Reports on Retail Sector, Motor Vehicle Repair and Sales Sector, Food and Beverages Sector.

    Science.gov (United States)

    European Centre for the Development of Vocational Training, Berlin (Germany).

    This document is composed of European synthesis reports on retail trade, the agro-food sector, and the motor vehicle sales and repair sector. They are based on the most important findings of the European report and the 12 national reports for each sector. Section 1, "Retail Sector," deals in part 1 with the structure of retailing in the…

  6. Training in the Motor Vehicle Repair and Sales Sector in Spain. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    European Centre for the Development of Vocational Training, Berlin (Germany).

    An international team of researchers studied the following aspects of training in Spain's motor vehicle repair and sales sector: structure and characteristics; institutional and social context; relationship to Spain's overall labor market; changing structural, economic, and organizational conditions; and training and recruitment and relationship…

  7. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  8. Motor Oil Classification using Color Histograms and Pattern Recognition Techniques.

    Science.gov (United States)

    Ahmadi, Shiva; Mani-Varnosfaderani, Ahmad; Habibi, Biuck

    2018-04-20

    Motor oil classification is important for quality control and the identification of oil adulteration. In thiswork, we propose a simple, rapid, inexpensive and nondestructive approach based on image analysis and pattern recognition techniques for the classification of nine different types of motor oils according to their corresponding color histograms. For this, we applied color histogram in different color spaces such as red green blue (RGB), grayscale, and hue saturation intensity (HSI) in order to extract features that can help with the classification procedure. These color histograms and their combinations were used as input for model development and then were statistically evaluated by using linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and support vector machine (SVM) techniques. Here, two common solutions for solving a multiclass classification problem were applied: (1) transformation to binary classification problem using a one-against-all (OAA) approach and (2) extension from binary classifiers to a single globally optimized multilabel classification model. In the OAA strategy, LDA, QDA, and SVM reached up to 97% in terms of accuracy, sensitivity, and specificity for both the training and test sets. In extension from binary case, despite good performances by the SVM classification model, QDA and LDA provided better results up to 92% for RGB-grayscale-HSI color histograms and up to 93% for the HSI color map, respectively. In order to reduce the numbers of independent variables for modeling, a principle component analysis algorithm was used. Our results suggest that the proposed method is promising for the identification and classification of different types of motor oils.

  9. Recurrent Tricuspid Insufficiency: Is the Surgical Repair Technique a Risk Factor?

    OpenAIRE

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair.

  10. Combined laparoscopic and open technique for repair of congenital abdominal hernia

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-01-01

    Abstract Background: Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. Materials and methods: We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. Results: The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Conclusions: Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality. PMID:29049186

  11. ON THE ROLE OF THE TECHNIQUES FACILITATING MOTOR RECOVERY

    Directory of Open Access Journals (Sweden)

    Corneliu BOTEZ

    2013-06-01

    Full Text Available Movement created a differentiated aparatus – the loco‐ motory one – the basic component of which is the kinetic unit, formed of joint‐movement‐nerves, each one playing a well‐established role, motivated only within an interde‐ pendence relation of the whole kinetic unit. Activation of the motor unit, considered as the smallest functional neu‐ romuscular unit described in 1925 by Liddel and Sher‐ rington, involves a series of complex processes, developed at the level of the three components (pericarion‐cylindrax‐ muscular fibers, the result being muscular contraction. The control of motricity, of the voluntary movements we perform so easily, sometimes wholly automatically, repre‐ sents a real computer performance, the organism organ‐ izing this type of control on successive levels, continuously enriching the phylogenetic scale, along the evolution of species, with new neuronal levels of integration, control and command. The scope of the present study was to evi‐ dence the efficiency of the facilitation techniques as to the following aspects of neuromotor recovery: recovery of the muscular tonus, recovery of the muscular power, increased joint mobility and recovery of movements coordination, by means of facilitation techniques. Materials and method. During January 2010‐January 2012, in the Military Hospital of Iaşi there have been hospitalized 120 patients with ages between 23‐64 years, with various etiologies of functional deficit: lumbosciatica with prolongued muscular contrac‐ tion in 52 cases – 43.33%, hemiplegia + arthroses 8 cases – 6.66%, systemic eritematous lupus 4 cases – 3.34%, post‐ fracture algoneurosistrophy (blocked knee 4 cases – 3.34%, rheumatoid polyarthritis – 24 cases – 20.00%, scapulo‐ humeral periarthritis 28 cases – 23.33%. Results and dis‐ cussion. The highest frequency of patients with neuro‐motor pathology requiring the application of some techniques facilitating

  12. [Motor nerves of the face. Surgical and radiologic anatomy of facial paralysis and their surgical repair].

    Science.gov (United States)

    Vacher, C; Cyna-Gorse, F

    2015-10-01

    Motor innervation of the face depends on the facial nerve for the mobility of the face, on the mandibular nerve, third branch of the trigeminal nerve, which gives the motor innervation of the masticator muscles, and the hypoglossal nerve for the tongue. In case of facial paralysis, the most common palliative surgical techniques are the lengthening temporalis myoplasty (the temporal is innervated by the mandibular nerve) and the hypoglossal-facial anastomosis. The aim of this work is to describe the surgical anatomy of these three nerves and the radiologic anatomy of the facial nerve inside the temporal bone. Then the facial nerve penetrates inside the parotid gland giving a plexus. Four branches of the facial nerve leave the parotid gland: they are called temporal, zygomatic, buccal and marginal which give innervation to the cutaneous muscles of the face. Mandibular nerve gives three branches to the temporal muscles: the anterior, intermediate and posterior deep temporal nerves which penetrate inside the deep aspect of the temporal muscle in front of the infratemporal line. The hypoglossal nerve is only the motor nerve to the tongue. The ansa cervicalis, which is coming from the superficial cervical plexus and joins the hypoglossal nerve in the submandibular area is giving the motor innervation to subhyoid muscles and to the geniohyoid muscle. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Integrated technique of planning the capital repair of residential buildings and objects of transport infrastructure

    Science.gov (United States)

    Dement'eva, Marina

    2017-10-01

    The paper presents the results of a comparative analysis of two fundamentally different methods for planning capital repairs of objects of transport infrastructure and residential development. The first method was based on perspective long-term plans. Normative service life were the basis for planning the periodicity of repairs. The second method was based on the performance of repairs in fact of the onset of the malfunction. Problems of financing repair work, of the uneven aging of constructs and engineering systems, different wear mechanism in different conditions of exploitation, absence of methods of planning repairs of administrative and production buildings (depots, stations, etc.) justify the need to optimize methods of planning the repair and the relevance of this paper. The aim of the study was to develop the main provisions of an integrated technique for planning the capital repair of buildings of any functional purpose, which combines the advantages of each of the discussed planning methods. For this purpose, the consequences of technical and economic risk were analyzed of the buildings, including stations, depots, transport transfer hubs, administrative buildings, etc when choosing different planning methods. One of the significant results of the study is the possibility of justifying the optimal period of capital repairs on the basis of the proposed technical and economic criteria. The adjustment of the planned repair schedule is carried out taking into account the reliability and cost-effectiveness of the exploitation process.

  14. One-flap Palatoplasty: A Cohort Study to Evaluate a Technique for Unilateral Cleft Palate Repair

    Directory of Open Access Journals (Sweden)

    Percy Rossell-Perry, PhD, FACS

    2015-04-01

    Conclusions: Use of a 1-flap technique for unilateral cleft palate repair allowed us to achieve results comparable to those of a 2-flap technique in terms of postoperative fistula development and hypernasal speech. Additional studies are required to evaluate the effect of this technique on palatal growth.

  15. New Surface-Treatment Technique of Concrete Structures Using Crack Repair Stick with Healing Ingredients.

    Science.gov (United States)

    Ahn, Tae-Ho; Kim, Hong-Gi; Ryou, Jae-Suk

    2016-08-04

    This study focused on the development of a crack repair stick as a new repair method along with self-healing materials that can be used to easily repair the cracks in a concrete structure at the construction site. In developing this new repair technique, the self-healing efficiency of various cementitious materials was considered. Likewise, a crack repair stick was developed to apply to concrete structures with 0.3 mm or lower crack widths. The crack repair stick was made with different materials, such as cement, an expansive material (C 12 A₇), a swelling material, and calcium carbonate, to endow it with a self-healing property. To verify the performance of the crack repair stick for concrete structures, two types of procedures (field experiment and field absorption test) were carried out. As a result of such procedures, it was concluded that the developed crack repair stick could be used on concrete structures to reduce repair expenses and for the improved workability, usability, and serviceability of such structures. On the other hand, to evaluate the self-healing performance of the crack repair stick, various tests were conducted, such as the relative dynamic modulus of elasticity test, the water tightness test, the water permeability test, observation via a microscope, and scanning electron microscope (SEM) analysis. From the results, it is found that water leakage can be prevented and that the durability of a concrete structure can be improved through self-healing. Also, it was verified that the cracks were perfectly closed after 28 days due to application of the crack repair stick. These results indicate the usability of the crack repair stick for concrete structures, and its self-healing efficiency.

  16. Transvaginal Cystocele Repair by Purse-String Technique Reinforced with Three Simple Sutures: Surgical Technique and Results

    Directory of Open Access Journals (Sweden)

    Ho-Sook Song

    2012-09-01

    Full Text Available Purpose Different techniques for cystocele repair including the conventional anterior colporrhaphy and mesh technique are known. Our goal was to evaluate the anatomical success and safety of our method of transvaginal anterior vaginal wall repair by the purse-string technique reinforced with three simple additional sutures in the repair of cystocele over a 4-year follow-up period. Methods This was a retrospective review of 69 consecutive patients (grades 2 to 4 who underwent the above operations between 2001 and 2011, including their success rates as assessed by use of the Baden-Walker halfway classification system. Results Of the patients, 62 patients (98% were completely cured of cystocele and 1 patient showed grade 2 cystocele recurrence that required no further treatment. Two patients with grade 4 cystocele were completely cured. There was no vaginal erosion related to the cystocele repair. Conclusions Transvaginal anterior colporrhaphy by a purse-string technique reinforced with simple additive sutures appears to be a simple, safe, and easily performed approach in cystocele repair. There is no need for other material for reinforcement, even in high-grade cystocele, which is an advantage of our technique.

  17. Brazing and diffusion bonding processes as available repair techniques for gas turbine blades and nozzles

    International Nuclear Information System (INIS)

    Mazur, Z.

    1997-01-01

    The conventionally welding methods are not useful for repair of heavily damaged gas turbine blades and nozzles. It includes thermal fatigue and craze cracks, corrosion, erosion and foreign object damage, which extend to the large areas. Because of required extensive heat input and couponing, it can cause severe distortion of the parts and cracks in the heat affected zone, and can made the repair costs high. For these cases, the available repair methods of gas turbine blades and nozzles, include brazing and diffusion bonding techniques are presented. Detailed analysis of the brazing and diffusion bonding processes applied for gas turbine blades repair with all elements which presented. Detailed analysis of the brazing and diffusion bonding processes applied for gas turbine blades repair with all elements which have influence to get sound joint is carried out. Depend of kind of blades and nozzle damage or deterioration registered a different methods of brazing and diffusion bonding applicability is presented. (Author) 65 refs

  18. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  19. Laparoscopic Pediatric Inguinal Hernia Repair: Overview of "True Herniotomy" Technique and Review of Current Evidence.

    Science.gov (United States)

    Feehan, Brendan P; Fromm, David S

    2017-05-01

    Inguinal hernia repair is one of the most commonly performed operations in the pediatric population. While the majority of pediatric surgeons routinely use laparoscopy in their practices, a relatively small number prefer a laparoscopic inguinal hernia repair over the traditional open repair. This article provides an overview of the three port laparoscopic technique for inguinal hernia repair, as well as a review of the current evidence with respect to visualization and identification of hernias, recurrence rates, operative times, complication rates, postoperative pain, and cosmesis. The laparoscopic repair presents a viable alternative to open repair and offers a number of benefits over the traditional approach. These include superior visualization of the relevant anatomy, ability to assess and repair a contralateral hernia, lower rates of metachronous hernia, shorter operative times in bilateral hernia, and the potential for lower complication rates and improved cosmesis. This is accomplished without increasing recurrence rates or postoperative pain. Further research comparing the different approaches, including standardization of techniques and large randomized controlled trials, will be needed to definitively determine which is superior. Copyright© South Dakota State Medical Association.

  20. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  1. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  2. IVO develops a new repair technique for underwater sites. Viscous doughlike substance underwater cracks

    Energy Technology Data Exchange (ETDEWEB)

    Klingstedt, G.; Leisio, C. [ed.

    1998-07-01

    A viscous sealant is revolutionizing repair of the stone and concrete masonry of underwater dams, bridges and canals. There is now no need for expensive and time-consuming cofferdams, since a diver can extrude quick-setting mortar into underwater structures needing repair. This technique has worked well in recent years in various parts of Finland even in strongly flowing water. IVO experts are now starting to look more beyond the borders of Finland

  3. A Novel Analytic Technique for the Service Station Reliability in a Discrete-Time Repairable Queue

    Directory of Open Access Journals (Sweden)

    Renbin Liu

    2013-01-01

    Full Text Available This paper presents a decomposition technique for the service station reliability in a discrete-time repairable GeomX/G/1 queueing system, in which the server takes exhaustive service and multiple adaptive delayed vacation discipline. Using such a novel analytic technique, some important reliability indices and reliability relation equations of the service station are derived. Furthermore, the structures of the service station indices are also found. Finally, special cases and numerical examples validate the derived results and show that our analytic technique is applicable to reliability analysis of some complex discrete-time repairable bulk arrival queueing systems.

  4. Techniques and outcome of repair of cleft of the secondary palate at ...

    African Journals Online (AJOL)

    Background: The technique adopted in the repair of cleft of the secondary palate must not just be based on the choice of the surgeon but on several factors which include the width of the cleft, length of palate and age of the patient. The aim of the article was to document our 4-year experience of the techniques and outcome ...

  5. The PASTA Bridge: A Technique for the Arthroscopic Repair of PASTA Lesions.

    Science.gov (United States)

    Hirahara, Alan M; Andersen, Wyatt J

    2017-10-01

    PASTA (partial articular supraspinatus tendon avulsion) lesions of greater than 50% thickness are usually repaired, whereas those of less than 50% thickness receive subacromial decompression and debridement. However, tears of greater than 25% thickness of the tendon result in increased strain of the adjacent, intact tendon fibers. Re-creating the tendon footprint at the greater tuberosity is the goal of a repair. Transtendon repairs have been considered the gold standard in repair but have shown varying outcomes and are technically difficult procedures. This report details the PASTA bridge-a technique for the arthroscopic, percutaneous repair of PASTA lesions. The PASTA bridge uses a spinal needle to ensure the repair includes the leading edge of the good tissue and is at the appropriate angle and area. Most procedures use a knife or trocar blindly to access the joint to place anchors, which has the potential to damage surrounding tissues and result in poor anchor and suture placement. The PASTA bridge is a safe, reliable procedure that is easily reproducible and appropriate for surgeons of all experience levels and should be strongly considered when repairing PASTA lesions.

  6. Single incision laparoscopic surgery (SILS) inguinal hernia repair - recent clinical experiences of this novel technique.

    Science.gov (United States)

    Yussra, Y; Sutton, P A; Kosai, N R; Razman, J; Mishra, R K; Harunarashid, H; Das, S

    2013-01-01

    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.

  7. Sexual dysfunction after inguinal hernia repair with the Onstep versus Lichtenstein technique

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Fonnes, Siv

    2017-01-01

    BACKGROUND: Sequelae after inguinal hernia repair include pain-related impairment of sexual function. Pain during intercourse can originate from the scar, scrotum, penis, or during ejaculation. The aim of this study was to investigate if the Onstep technique resulted in better results than...... the Lichtenstein technique regarding pain-related impairment of sexual function. METHODS: This study was part of the randomized ONLI trial (NCT01753219, Onstep versus Lichtenstein for inguinal hernia repair). Separate reporting of pain-related impairment of sexual function was planned before the study start......, with a separate sample size calculation. Participants were randomized to the Onstep or Lichtenstein technique for repair of their primary inguinal hernia and followed up at 6 months postoperative with the use of a questionnaire specific for pain-related impairment of sexual function. RESULTS: A total of 259...

  8. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Science.gov (United States)

    Jungmann, Pia M.; Baum, Thomas; Bauer, Jan S.; Karampinos, Dimitrios C.; Link, Thomas M.; Li, Xiaojuan; Trattnig, Siegfried; Rummeny, Ernst J.; Woertler, Klaus; Welsch, Goetz H.

    2014-01-01

    Background. New quantitative magnetic resonance imaging (MRI) techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC), and diffusion weighted imaging (DWI) are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair. PMID:24877139

  9. Cartilage Repair Surgery: Outcome Evaluation by Using Noninvasive Cartilage Biomarkers Based on Quantitative MRI Techniques?

    Directory of Open Access Journals (Sweden)

    Pia M. Jungmann

    2014-01-01

    Full Text Available Background. New quantitative magnetic resonance imaging (MRI techniques are increasingly applied as outcome measures after cartilage repair. Objective. To review the current literature on the use of quantitative MRI biomarkers for evaluation of cartilage repair at the knee and ankle. Methods. Using PubMed literature research, studies on biochemical, quantitative MR imaging of cartilage repair were identified and reviewed. Results. Quantitative MR biomarkers detect early degeneration of articular cartilage, mainly represented by an increasing water content, collagen disruption, and proteoglycan loss. Recently, feasibility of biochemical MR imaging of cartilage repair tissue and surrounding cartilage was demonstrated. Ultrastructural properties of the tissue after different repair procedures resulted in differences in imaging characteristics. T2 mapping, T1rho mapping, delayed gadolinium-enhanced MRI of cartilage (dGEMRIC, and diffusion weighted imaging (DWI are applicable on most clinical 1.5 T and 3 T MR scanners. Currently, a standard of reference is difficult to define and knowledge is limited concerning correlation of clinical and MR findings. The lack of histological correlations complicates the identification of the exact tissue composition. Conclusions. A multimodal approach combining several quantitative MRI techniques in addition to morphological and clinical evaluation might be promising. Further investigations are required to demonstrate the potential for outcome evaluation after cartilage repair.

  10. Repair of lesser tuberosity osteotomy for shoulder arthroplasty: biomechanical evaluation of the Backpack and Dual Row techniques.

    Science.gov (United States)

    Heckman, Daniel S; Hoover, Stephen A; Weinhold, Paul S; Spang, Jeffrey T; Creighton, R Alexander

    2011-04-01

    Subscapularis dysfunction following total shoulder arthroplasty can result in permanent loss of function. The lesser tuberosity osteotomy (LTO) has been proposed as a method which utilizes bone-to-bone healing to improve subscapularis function. This study evaluates the biomechanical properties of two described techniques for LTO repair. We hypothesized that a Dual Row repair would be stronger and demonstrate less cyclic displacement than a Backpack repair. Ten matched pairs of cadaveric humeri were dissected, leaving the subscapularis intact, and a lesser tuberosity osteotomy was performed. Matched shoulders were randomized to either a Backpack repair or a Dual Row repair. Repairs were subjected to cyclic loading to 180 N for 500 cycles, followed by ramp-up loading to ultimate failure. Clinical failure was defined as displacement >5 mm after 500 cycles. Displacement after 500 cycles was significantly greater for the Backpack repair (6.9 mm) than for the Dual Row repair (4.6 mm) (P = .007). Most displacement occurred on the first cycle (Backpack, 4.6 mm; Dual Row, 2.1 mm) (P Row repair (3/10). Ultimate tensile strength was significantly greater for the Dual Row repair (632.3 N) than for the Backpack repair (510.9 N) (P = .01). The Dual Row technique is significantly stronger and demonstrates less cyclic displacement than the Backpack technique. Clinical studies are needed to determine the impact of LTO repair technique on subscapularis function following shoulder arthroplasty. Copyright © 2011. Published by Mosby, Inc.

  11. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  12. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    Science.gov (United States)

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Comparison the Impact of Spark Motor Program and Basketball Techniques on Improving Gross Motor Skills in Educable Intellectually Disabled Boys

    Directory of Open Access Journals (Sweden)

    Hashem Faal Moghanlo

    2014-09-01

    Full Text Available Background & objectives : Different types of practises are known for improving motor skills in intellectually disabled boys. The purpose of this study was to compar e the impact of spark motor program and basketball on improving of gross motor skills in this people.   Methods: In this semi-experimental study , from 98 educable intellectually disabled students who studied in special school in Urmia, 30 children ( age range of 9 to 13 years and IQ mean 64.4 were selected objectively and divided in three groups (2 experimental and 1 control based on pre - test. BOTMP was used as a measurement of motor ability. Selected motor program (Spark motor program including strengthening training, games, sports and basketball techniques was performed for 24 sessions. T-tests (dependent and co-variance were used to comparison of results.   Results: In Spark group after 24 sessions, there were significant effects on balance (p= 0.000, bilateral coordination (p=0.000 and strength (p=0.001. There was no significant effect in agility and speed (p= 0.343 in basketball techniques group after 24 sessions, there were significant effects in agility and speed (p= 0.001, balance (p= 0.000, bilateral coordination (p= 0.013 and strength (p= 0.007.   Conclusion: Based on the results of this study, it can be claimed that the Spark program and basketball techniques improve gross motor skills in educable intellectually disabled students. We also found a significant difference between the Spark program and basketball techniques efficacy on the improved skills. Furthermore, the efficacy of Spark program was significantly higher than basketball techniques (p<0.05.

  14. Determination of damage and In vivo DNA repairing through the unicellular in gel electrophoresis technique

    International Nuclear Information System (INIS)

    Mendiola C, M.T.; Morales R, P.

    1997-01-01

    The experimental conditions were standardized for the unicellular in gel electrophoresis technique setting up (EUG) at the Cellular Radiobiology laboratory. Preliminary experiments were realized with human cells and mouse which were exposed to ionizing radiation or hydroxide peroxide (H 2 O 2 ) to induce DNA damage and to verify the technique performance. It was analysed the In vivo repairing kinetics of induced damage by gamma radiation in mouse leukocytes which were exposed to 137 Cs source and taking samples of peripheric blood of the tail of each mouse at different exposure times and processing them for EUG. In function of the cells proportion with damage in each time it was determined the existence of fast repairing mechanism at the first 15 minutes followed by a slight increase in the damage and a late repairing stage between 30 and 90 minutes. It was analysed this behavior and the potentiality of this In vivo system. (Author)

  15. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  16. AC electric motors control advanced design techniques and applications

    CERN Document Server

    Giri, Fouad

    2013-01-01

    The complexity of AC motor control lies in the multivariable and nonlinear nature of AC machine dynamics. Recent advancements in control theory now make it possible to deal with long-standing problems in AC motors control. This text expertly draws on these developments to apply a wide range of model-based control designmethods to a variety of AC motors. Contributions from over thirty top researchers explain how modern control design methods can be used to achieve tight speed regulation, optimal energetic efficiency, and operation reliability and safety, by considering online state var

  17. Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

    Science.gov (United States)

    Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Sutker, Michael J

    2009-09-01

    To evaluate the biomechanical characteristics of current meniscal repair techniques containing ultra high-molecular weight polyethylene (UHMWPE) suture with and without cyclic loading. Vertical longitudinal cuts made in porcine menisci were secured with a single repair device. Noncycled and cycled (500 cycles) biomechanical tests were performed on the following groups: group 1, No. 2-0 Mersilene vertical suture (Ethicon, Somerville, NJ); group 2, No. 2-0 Orthocord vertical suture (DePuy Mitek, Westwood, MA); group 3, No. 0 Ultrabraid vertical suture (Smith & Nephew Endoscopy, Andover, MA); group 4, No. 2-0 FiberWire vertical suture (Arthrex, Naples, FL); group 5, vertically oriented mattress suture by use of an Ultra FasT-Fix device (Smith & Nephew Endoscopy) with No. 0 Ultrabraid; group 6, vertically oriented mattress suture by use of a RapidLoc A2 device (DePuy Mitek) with No. 2-0 Orthocord suture; group 7, vertically oriented stitch by use of a MaxFire device with MaxBraid PE suture (Biomet Sports Medicine, Warsaw, IN); and group 8, an obliquely oriented stitch of No. 0 UHMWPE suture inserted by use of a CrossFix device (Cayenne Medical, Scottsdale, AZ). Endpoints were failure loads, failure modes, stiffness, and cyclic displacement. Mean single-pull loads were calculated for Ultra FasT-Fix (121 N), FiberWire (110 N), MaxFire (130 N), Mersilene (84 N), Orthocord (124 N), RapidLoc A2 (86 N), CrossFix (77 N), and Ultrabraid (109 N). After 500 cyclic loads, the Orthocord (222 N) repair was stronger than the others: Ultra FasT-Fix (110 N), FiberWire (117 N), MaxFire (132 N), Mersilene (89 N), RapidLoc A2 (108 N), CrossFix (95 N), and Ultrabraid (126 N) (P Fix, RapidLoc A2, and MaxFire) were comparable to the isolated UHMWPE-containing suture repairs on single-failure load testing. UHMWPE-containing suture repairs are stronger than braided polyester suture repairs, but pure UHMWPE suture (Ultrabraid) elongated more during cycling. Orthocord suture is significantly

  18. Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial.

    Science.gov (United States)

    Randelli, Pietro; Stoppani, Carlo Alberto; Zaolino, Carlo; Menon, Alessandra; Randelli, Filippo; Cabitza, Paolo

    2017-07-01

    Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic. To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. Randomized controlled trial; Level of evidence, 1. Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories. Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81). No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).

  19. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  20. Minilaparoscopic technique for inguinal hernia repair combining transabdominal pre-peritoneal and totally extraperitoneal approaches.

    Science.gov (United States)

    Carvalho, Gustavo L; Loureiro, Marcelo P; Bonin, Eduardo A; Claus, Christiano P; Silva, Frederico W; Cury, Antonio M; Fernandes, Flavio A M

    2012-01-01

    Endoscopic surgical repair of inguinal hernia is currently conducted using 2 techniques: the totally extraperitoneal (TEP) and the transabdominal (TAPP) hernia repair. The TEP procedure is technically advantageous, because of the use of no mesh fixation and the elimination of the peritoneal flap, leading to less postoperative pain and faster recovery. The drawback is that TEP is not performed as frequently, because of its complexity and longer learning curve. In this study, we propose a hybrid technique that could potentially become the gold standard of minimally invasive inguinal hernia surgery. This will be achieved by combining established advantages of TEP and TAPP associated with the precision and cosmetics of minilaparoscopy (MINI). Between January and July 2011, 22 patients were admitted for endoscopic inguinal hernia repair. The combined technique was initiated with TAPP inspection and direct visualization of a minilaparoscopic trocar dissection of the preperitoneum space. A10-mm trocar was then placed inside the previously dissected preperitoneal space, using the same umbilical TAPP skin incision. Minilaparoscopic retroperitoneal dissection was completed by TEP, and the surgical procedure was finalized with intraperitoneal review and correction of the preperitoneal work. The minilaparoscopic TEP-TAPP combined approach for inguinal hernia is feasible, safe, and allows a simple endoscopic repair. This is achieved by combining features and advantages of both TAPP and TEP techniques using precise and sophisticated MINI instruments. Minilaparoscopic preperitoneal dissection allows a faster and easier creation of the preperitoneal space for the TEP component of the procedure.

  1. On failure of the pruning technique in "error repair in shift-reduce parsers"

    NARCIS (Netherlands)

    Bertsch, E; Nederhof, MJ

    A previous article presented a technique to compute the least-cost error repair by incrementally generating configurations that result from inserting and deleting tokens in a syntactically incorrect input. An additional mechanism to improve the run-time efficiency of this algorithm by pruning some

  2. A 5‑year Review of Darning Technique of Inguinal Hernia Repair

    African Journals Online (AJOL)

    modes of presentation,[8,9] and in many hospitals where the experience ... will be ideal. This study aims to present our experience with the use of the. Darning technique for repair of inguinal hernia in a Nigerian ... Study Design: A descriptive retrospective study ... site infection was the most common complication occurring in.

  3. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Bryan G. Vopat

    2014-05-01

    Full Text Available Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthro- scopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author’s practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001. This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  4. Biomechanical Comparison of Arthroscopic Single- and Double-Row Repair Techniques for Acute Bony Bankart Lesions.

    Science.gov (United States)

    Spiegl, Ulrich J; Smith, Sean D; Todd, Jocelyn N; Coatney, Garrett A; Wijdicks, Coen A; Millett, Peter J

    2014-08-01

    Single- and double-row arthroscopic reconstruction techniques for acute bony Bankart lesions have been described in the literature. The double-row fixation technique would provide superior reduction and stability of a simulated bony Bankart lesion at time zero in a cadaveric model compared with the single-row technique. Controlled laboratory study. Testing was performed on 14 matched pairs of glenoids with simulated bony Bankart fractures with a defect width of 25% of the glenoid diameter. Half of the fractures were repaired with a double-row technique, while the contralateral glenoids were repaired with a single-row technique. The quality of fracture reduction was measured with a coordinate measuring machine. To determine the biomechanical stability of the repairs, specimens were preconditioned with 10 sinusoidal cycles between 5 and 25 N at 0.1 Hz and then pulled to failure in the anteromedial direction at a rate of 5 mm/min. Loads at 1 mm and 2 mm of fracture displacement were determined. The double-row technique required significantly higher forces to achieve fracture displacements of 1 mm (mean, 60.6 N; range, 39.0-93.3 N; P = .001) and 2 mm (mean, 94.4 N; range, 43.4-151.2 N; P = .004) than the single-row technique (1 mm: mean, 30.2 N; range, 14.0-54.1 N and 2 mm: mean, 63.7 N; range, 26.6-118.8 N). Significantly reduced fracture displacement was seen after double-row repair for both the unloaded condition (mean, 1.1 mm; range, 0.3-2.4 mm; P = .005) and in response to a 10-N anterior force applied to the defect (mean, 1.6 mm; range, 0.5-2.7 mm; P = .001) compared with single-row repair (unloaded: mean, 2.1 mm; range, 1.3-3.4 mm and loaded: mean, 3.4 mm; range, 1.9-4.7 mm). The double-row fixation technique resulted in improved fracture reduction and superior stability at time zero in this cadaveric model. This information may influence the surgical technique used to treat large osseous Bankart fractures and the postoperative rehabilitation protocols

  5. Current surgical practices in cleft care: cleft palate repair techniques and postoperative care.

    Science.gov (United States)

    Katzel, Evan B; Basile, Patrick; Koltz, Peter F; Marcus, Jeffrey R; Girotto, John A

    2009-09-01

    The purpose of this study was to objectively report practices commonly used in cleft palate repair in the United States. This study investigates current surgical techniques, postoperative care, and complication rates for cleft palate repair surgery. All 803 surgeon members of the American Cleft Palate-Craniofacial Association were sent online and/or paper surveys inquiring about their management of cleft palate patients. Three-hundred six surveys were received, a 38 percent response rate. This represented responses of surgeons from 100 percent of American Cleft Palate-Craniofacial Association registered cleft teams. Ninety-six percent of respondents perform a one-stage repair. Eighty-five percent of surgeons perform palate surgery when the patient is between 6 and 12 months of age. The most common one-stage repair techniques are the Bardach style (two flaps) with intravelar veloplasty and the Furlow palatoplasty. After surgery, 39 percent of surgeons discharge patients within 24 hours. Another 43 percent discharge patients within 48 hours. During postoperative management, 92 percent of respondents implement feeding restrictions. Eighty-five percent of physicians use arm restraints. Surgeons' self-reported complications rates are minimal: 54 percent report a fistula in less than 5 percent of cases. The reported need for secondary speech surgery varies widely. The majority of respondents repair clefts in one stage. The most frequently used repair techniques are the Furlow palatoplasty and the Bardach style with intravelar veloplasty. After surgery, the majority of surgeons discharge patients in 1 or 2 days, and nearly all surgeons implement feeding restrictions and the use of arm restraints. The varying feeding protocols are reviewed in this article.

  6. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    Science.gov (United States)

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  7. 'Batman excision' of ventral skin in hypospadias repair, clue to aesthetic repair (point of technique).

    Science.gov (United States)

    Hoebeke, P B; De Kuyper, P; Van Laecke, E

    2002-11-01

    In the hypospadiac penis the ventral skin is poorly developed, while dorsal skin is redundant. The classical Byars' flaps are a way to use the excess dorsal skin to cover the penile shaft. The appearance after Byars' flaps however is not natural. We use a more natural looking skin allocation with superior aesthetic results. The clue in this reconstruction is an inverted triangle shaped excision of ventral skin expanding over the edges of the hooded prepuce (which makes it look like Batman). After excision of the ventral skin it is possible to close the penile skin in the midline, thus mimicking the natural raphe. In case of preputial reconstruction the excised ventral skin makes the prepuce look more natural. The trend of further refining aesthetic appearance of the hypospadiac penis often neglects the penile skin reconstruction. A technique is presented by which the total penile appearances after surgery ameliorates due to better skin reconstruction.

  8. A new technique for repair of a dislocated sternoclavicular joint using a sternal tension cable system.

    Science.gov (United States)

    Janson, Jacques T; Rossouw, Gawie J

    2013-02-01

    An unstable anterior or posterior sternoclavicular joint dislocation can cause severe morbidity with poor shoulder movement and strength. These dislocations need to be repaired, which can be challenging. Many different procedures have been described to obtain a stable joint fixation with varying results. We report a new technique for repairing a sternoclavicular joint dislocation by using a figure-of-eight sternal cable system. This procedure is relatively simple and reproducible to create a stable and functional sternoclavicular joint. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  10. Design and Comparison Direct Torque Control Techniques for Induction Motors

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Kazmierkowski, Marian P.; Zelechowski, Marcin

    2005-01-01

    In this paper a comparison of two significant control methods of induction motor are presented. The first one is a classical Direct Torque and Flux Control (DTC) and is compared with a scheme, which uses Space Vector Modulator (DTC-SVM). A comparison in respect to dynamic and steady state...

  11. Control and sensor techniques for PAD servo motor drive

    DEFF Research Database (Denmark)

    Zsurzsan, Tiberiu-Gabriel; Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    The Piezoelectric Actuator Drive (PAD) is a new type of electrical motor that employs piezoelectric multilayer actuators coupled with a form-fitted micro-mechanical gearing to generate rotary motion. The PAD is precise, having a positioning error of less than 2 arc-seconds. Its typical output...

  12. Multilevel Spondylolysis Repair Using the "Smiley Face" Technique with 3-Dimensional Intraoperative Spinal Navigation.

    Science.gov (United States)

    Voisin, Mathew R; Witiw, Christopher D; Deorajh, Ryan; Guha, Daipayan; Oremakinde, Adetunji; Wang, Shelly; Yang, Victor

    2018-01-01

    Multilevel spondylolysis is a rare cause of progressive lower back pain, and patients who fail conservative management are treated surgically. Direct repair methods can maintain mobility and lead to decreased morbidity compared with spinal fusion in single-level spondylolysis. In this paper, we present a patient with nonadjacent multilevel spondylolysis who underwent the "smiley face" technique of direct multilevel repair without fusion using 3-dimensional intraoperative spinal navigation. Bilateral spondylolysis at L3 and L5 with associated spondylolisthesis in a 50-year-old male was repaired using the "smiley face" technique. Patient-reported outcomes, including the Oswestry Disability Index (ODI) and visual analog scale scores for back and leg pain, were assessed preoperatively along with 6 weeks and 4 months postoperatively. Postoperative computed tomography imaging showed precise screw insertion and rod placement along with stable hardware alignment in follow-up imaging. The patient's ODI and lower back visual analog scale scores decreased from 25 to 8 and 7.5 to 4, respectively, correlating to an excellent outcome on ODI. Direct repair and avoidance of fusion is possible and can provide good functional outcomes in patients with nonadjacent multilevel spondylolysis and associated spondylolisthesis. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Fault location repair, rewinding and commissioning of 3.3 kV, 850 kW synchronous motor (Paper No. 5.9)

    International Nuclear Information System (INIS)

    Subramanian, A.R.; Palani, R.A.A.

    1992-01-01

    The 20K41 compressor in Heavy Water Plant, Tuticorin is compressing medium pressure synthesis gas to high pressure. The compressor is driven by synchronous motor of capacity 850 kW at 3.3 kV. The synchronous motor had been selected for operating a reciprocating compressor because of the compressor's low speed, higher capacity, vibration level etc. Partially it helps for power factor improvement and constant compression of the gas. This paper describes the details of the motor, stator and rotor, method of repair and rewinding of synchronous motor. (author)

  14. THE POWER FACTOR IMPROVING OF THE MOTORS IN ENTERPRISES WITH REPAIR OF RAILWAY EQUIPMENT

    Directory of Open Access Journals (Sweden)

    O. L. Marenych

    2008-03-01

    Full Text Available In this article the following problem has been considered: ways of power factor increase for electric drives installed at the railway machinery repair enterprises with taking into account the specific conditions of technological processes.

  15. The initial experience of introducing the Onstep technique for inguinal hernia repair in a general surgical department

    DEFF Research Database (Denmark)

    Andresen, K; Burcharth, Jakob Hornstrup Frølunde; Rosenberg, J

    2015-01-01

    BACKGROUND AND AIMS: A new technique for the repair of inguinal hernia, called Onstep, has been described. This technique places the mesh in the preperitoneal space medially and between the internal and external oblique muscles laterally. The Onstep technique has not yet been described outside...... repair. Inguinal Pain Questionnaire results: 95.5% reported no pain or pain that was easily ignored. CONCLUSIONS: It seems from this study that the Onstep technique is a safe method for inguinal hernia repair regarding perioperative and postoperative complications. The postoperative pain seems...

  16. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    Science.gov (United States)

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  17. Novel technique for repairing posterior medial meniscus root tears using porcine knees and biomechanical study.

    Directory of Open Access Journals (Sweden)

    Jia-Lin Wu

    Full Text Available Transtibial pullout suture (TPS repair of posterior medial meniscus root (PMMR tears was shown to achieve good clinical outcomes. The purpose of this study was to compare biomechanically, a novel technique designed to repair PMMR tears using tendon graft (TG and conventional TPS repair. Twelve porcine tibiae (n = 6 each TG group: flexor digitorum profundus tendon was passed through an incision in the root area, created 5 mm postero-medially along the edge of the attachment area. TPS group: a modified Mason-Allen suture was created using no. 2 FiberWire. The tendon grafts and sutures were threaded through the bone tunnel and then fixed to the anterolateral cortex of the tibia. The two groups underwent cyclic loading followed by a load-to-failure test. Displacements of the constructs after 100, 500, and 1000 loading cycles, and the maximum load, stiffness, and elongation at failure were recorded. The TG technique had significantly lower elongation and higher stiffness compared with the TPS. The maximum load of the TG group was significantly lower than that of the TPS group. Failure modes for all specimens were caused by the suture or graft cutting through the meniscus. Lesser elongation and higher stiffness of the constructs in TG technique over those in the standard TPS technique might be beneficial for postoperative biological healing between the meniscus and tibial plateau. However, a slower rehabilitation program might be necessary due to its relatively lower maximum failure load.

  18. Training in the Motor Vehicle Repair and Sales Sector in Ireland. Report for the FORCE Programme.

    Science.gov (United States)

    Tuite, Dominick

    A study viewed the existing motor vehicle sector, structure, and trading conditions and identified and analyzed the best and most significant continuing vocational training practices in Ireland. In 1991, the motor vechicle sector accounted for 6.2 percent of the Gross National Product. Employment in the sector has decreased from an estimated…

  19. An Enhanced Vacuum Cure Technique for On-Aircraft Repair of Carbon-Bismaleimide Composites

    Science.gov (United States)

    Rider, Andrew N.; Baker, Alan A.; Wang, Chun H.; Smith, Graeme

    2011-06-01

    Carbon/bismaleimide (BMI) composite is increasingly employed in critical load carrying aircraft structures designed to operate at temperatures approaching 180°C. The high post-cure temperature (above 220°C) required to fully react the BMI resin, however, renders existing on-aircraft prepreg or wet layup repair methods invalid. This paper presents a new on-aircraft repair technique for carbon/BMI composites. The composite prepregs are first warm-staged to improve the ability to evacuate entrapped air. Then the patch is cured in the scarf cavity using the vacuum bag technique, followed by off-aircraft post-cure. The fully cured patch then can be bonded using a structural adhesive.

  20. Congenital superior sternal cleft repair using our modified Sally technique: A case report

    Directory of Open Access Journals (Sweden)

    Tomoyuki Kuwata

    2014-12-01

    Full Text Available We report the case of an 8-month-old male neonate who underwent reconstructive surgery for a congenital superior sternal cleft to decrease the risk of commotio cordis. With regard to use of the Sally technique for the repair of a relatively wide cleft (4 × 4 cm, we were concerned about respiratory problems caused by compression following closure of the sternal halves. By closing the sternal halves imperfectly, elevation of intrapleural pressure can be avoided to some extent. By bridging the surplus resected cartilage from the lower sternum over the gap of the upper sternum, the heart is protected by more rigid material. We recommend our modified Sally technique because it is both flexible and effective for sternal cleft repair.

  1. Development of laser repair technique for cutting impurities in secondary side of a steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Jung; Chung, Chin Man; Kim, Min Suk; Jeong, Tae Moon

    1999-12-01

    In this research, the laser repair technique was investigated for the purpose of cutting impurities in secondary side of a steam generator. For this research, a high quality Nd:YAG laser was manufactured and the beam delivery experiments was performed with multimode optical fibers. Also, the small size focusing system was designed and fabricated for remote cutting and the laser cutting experiment was performed. (author)

  2. Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique.

    Science.gov (United States)

    Savvidou, Christiana; Tsai, Tsu-Min

    2015-06-01

    The purpose of this study is to report the clinical results after repair of flexor tendon zone II injuries utilizing a 6-strand double-loop technique and early post-operative active rehabilitation. We retrospectively reviewed 22 patients involving 51 cases with zone II flexor tendon repair using a six strand double loop technique from September 1996 to December 2012. Most common mechanism of injuries was sharp lacerations (86.5 %). Tendon injuries occurred equally in manual and non-manual workers and were work-related in 33 % of the cases. The Strickland score for active range of motion (ROM) postoperatively was excellent and good in the majority of the cases (81 %). The rupture rate was 1.9 %. The six strand double loop technique for Zone II flexor tendon repair leads to good and excellent motion in the majority of patients and low re- rupture rate. It is clinically effective and allows for early postoperative active rehabilitation.

  3. Critical and subcritical damage monitoring of bonded composite repairs using innovative non-destructive techniques

    Science.gov (United States)

    Grammatikos, S. A.; Kordatos, E. Z.; Aggelis, D. G.; Matikas, T. E.; Paipetis, A. S.

    2012-04-01

    Infrared Thermography (IrT) has been shown to be capable of detecting and monitoring service induced damage of repair composite structures. Full-field imaging, along with portability are the primary benefits of the thermographic technique. On-line lock-in thermography has been reported to successfully monitor damage propagation or/and stress concentration in composite coupons, as mechanical stresses in structures induce heat concentration phenomena around flaws. During mechanical fatigue, cyclic loading plays the role of the heating source and this allows for critical and subcritical damage identification and monitoring using thermography. The Electrical Potential Change Technique (EPCT) is a new method for damage identification and monitoring during loading. The measurement of electrical potential changes at specific points of Carbon Fiber Reinforced Polymers (CFRPs) under load are reported to enable the monitoring of strain or/and damage accumulation. Along with the aforementioned techniques Finally, Acoustic Emission (AE) method is well known to provide information about the location and type of damage. Damage accumulation due to cyclic loading imposes differentiation of certain parameters of AE like duration and energy. Within the scope of this study, infrared thermography is employed along with AE and EPCT methods in order to assess the integrity of bonded repair patches on composite substrates and to monitor critical and subcritical damage induced by the mechanical loading. The combined methodologies were effective in identifying damage initiation and propagation of bonded composite repairs.

  4. Correlation between histological outcome and surgical cartilage repair technique in the knee: A meta-analysis.

    Science.gov (United States)

    DiBartola, Alex C; Everhart, Joshua S; Magnussen, Robert A; Carey, James L; Brophy, Robert H; Schmitt, Laura C; Flanigan, David C

    2016-06-01

    Compare histological outcomes after microfracture (MF), autologous chondrocyte implantation (ACI), and osteochondral autograft transfer (OATS). Literature review using PubMed MEDLINE, SCOPUS, Cumulative Index for Nursing and Allied Health Literature (CINAHL), and Cochrane Collaboration Library. Inclusion criteria limited to English language studies International Cartilage Repair Society (ICRS) grading criteria for cartilage analysis after ACI (autologous chondrocyte implantation), MF (microfracture), or OATS (osteochondral autografting) repair techniques. Thirty-three studies investigating 1511 patients were identified. Thirty evaluated ACI or one of its subtypes, six evaluated MF, and seven evaluated OATS. There was no evidence of publication bias (Begg's p=0.48). No statistically significant correlation was found between percent change in clinical outcome and percent biopsies showing ICRS Excellent scores (R(2)=0.05, p=0.38). Percent change in clinical outcome and percent of biopsies showing only hyaline cartilage were significantly associated (R(2)=0.24, p=0.024). Mean lesion size and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Most common lesion location and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Microfracture has poorer histologic outcomes than other cartilage repair techniques. OATS repairs primarily are comprised of hyaline cartilage, followed closely by cell-based techniques, but no significant difference was found cartilage quality using ICRS grading criteria among OATS, ACI-C, MACI, and ACI-P. IV, meta-analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model

    Science.gov (United States)

    Redler, Lauren H.; Byram, Ian R.; Luchetti, Timothy J.; Tsui, Ying Lai; Moen, Todd C.; Gardner, Thomas R.; Ahmad, Christopher S.

    2014-01-01

    Background: Redundancies in the rotator cuff tissue, commonly referred to as “dog ear” deformities, are frequently encountered during rotator cuff repair. Knowledge of how these deformities are created and their impact on rotator cuff footprint restoration is limited. Purpose: The goals of this study were to assess the impact of tear size and repair method on the creation and management of dog ear deformities in a human cadaveric model. Study Design: Controlled laboratory study. Methods: Crescent-shaped tears were systematically created in the supraspinatus tendon of 7 cadaveric shoulders with increasing medial to lateral widths (0.5, 1.0, and 1.5 cm). Repair of the 1.5-cm tear was performed on each shoulder with 3 methods in a randomized order: suture bridge, double-row repair with 2-mm fiber tape, and fiber tape with peripheral No. 2 nonabsorbable looped sutures. Resulting dog ear deformities were injected with an acrylic resin mixture, digitized 3-dimensionally (3D), and photographed perpendicular to the footprint with calibration. The volume, height, and width of the rotator cuff tissue not in contact with the greater tuberosity footprint were calculated using the volume injected, 3D reconstructions, and calibrated photographs. Comparisons were made between tear size, dog ear measurement technique, and repair method utilizing 2-way analysis of variance and Student-Newman-Keuls multiple-comparison tests. Results: Utilizing 3D digitized and injection-derived volumes and dimensions, anterior dog ear volume, height, and width were significantly smaller for rotator cuff repair with peripheral looped sutures compared with a suture bridge (P repair with 2-mm fiber tape alone (P repair with looped peripheral sutures compared with a suture bridge (P repair technique, peripheral No. 2 nonabsorbable looped sutures significantly decreased the volume, height, and width of dog ear deformities, better restoring the anatomic footprint of the rotator cuff. Clinical

  6. A simple novel technique [PUIT] for closure of urethrocutaneous fistula after hypospadias repair: Preliminary results

    Directory of Open Access Journals (Sweden)

    Awad M

    2005-01-01

    Full Text Available Urethrocutaneous fistula is a common complication of urethroplasty for severe hypospadias, even when a microsurgical technique is applied, the closure of the fistula is a challenging problem. We present a simple surgical procedure, posterior urethral incision technique [PUIT] to close the fistula in our department. Between February 2001 and December 2004 we prospectively evaluated 32 patients, 26 patients with initial hypospadias fistulas and 6 with recurrent fistulas who underwent closure of urethrocutaneous fistula after hypospadias repair. The mean age of patients was 5 years, the operation consisted of trimming the fistula edge after mobilization of the skin all-around then a midline posterior urethral incision was done 2 mm above and 2 mm below the fistula opening then re-approximation of the urethral edges using 6/0 vicryl sutures with loop magnification. The timing of fistula repair was between 6 and 13 months after it was formed, all of these were effectively closed except three cases with stricture and fistula. Of these, two were completely relieved after repeated urethral dilatation, three times a week for 2 weeks. The third failed case will need another sitting after 6 months. The posterior midline urethral incision gives a good opportunity for repair without tension with a good cosmetic outcome. This may be done under local anesthesia in adults. The procedure is considered simple rapid and easy to be done for variable fistulas types whatever of its site and the age.

  7. Cell Seeding Densities in Autologous Chondrocyte Implantation Techniques for Cartilage Repair.

    Science.gov (United States)

    Foldager, Casper Bindzus; Gomoll, Andreas H; Lind, Martin; Spector, Myron

    2012-04-01

    Cartilage repair techniques have been among the most intensively investigated treatments in orthopedics for the past decade, and several different treatment modalities are currently available. Despite the extensive research effort within this field, the generation of hyaline cartilage remains a considerable challenge. There are many parameters attendant to each of the cartilage repair techniques that can affect the amount and types of reparative tissue generated in the cartilage defect, and some of the most fundamental of these parameters have yet to be fully investigated. For procedures in which in vitro-cultured autologous chondrocytes are implanted under a periosteal or synthetic membrane cover, or seeded onto a porous membrane or scaffold, little is known about how the number of cells affects the clinical outcome. Few published clinical studies address the cell seeding density that was employed. The principal objective of this review is to provide an overview of the cell seeding densities used in cell-based treatments currently available in the clinic for cartilage repair. Select preclinical studies that have informed the use of specific cell seeding densities in the clinic are also discussed.

  8. Controlled, all-position, butterbead-temperbead welding technique for nuclear repairs

    International Nuclear Information System (INIS)

    Clark, J.N.; Lambert, J.A.

    1986-01-01

    Sections III and XI of the ASME boiler and pressure vessel code describe a half-bead temper repair welding technique specifically designed for in-service BWR and PWR repair applications without postweld heat treatment. The method relies on deposition of two layers of weld beads. Prior to deposition of the second layer, half the first layer is ground away. As a result, the first layer HAZ is tempered or retransformed by the second layer heat input. It is on the basis of this tempering that a concession is granted to omit postweld heat treatment. The grinding stage is difficult to control, time consuming, and can involve long exposure of personnel to a radioactive environment. Consequently, there has been pressure to find a viable alternative to the half-bead technique. Much interest has been shown in the butterbead-temperbead technique, which is essentially the CEGB two-layer HAZ refinement technique. This does not require grinding of the first layer and achieves HAZ retransformation by increasing the heat input of the second layer. The elimination of the grinding stage considerably reduces repair time and, consequently, radiation exposure. The method has now been included as an acceptable alternative to the half-bead technique in section XI of the ASME code. The CEGB method has been used successfully in the U.K. power industry, mainly for prevention of stress relief cracking, but also to improve HAZ toughness for low temperature service. Two-layer HAZ refinement is achieved by retransformation of the first layer HAZ by the thermal field of the second layer

  9. End-to-side neurorrhaphy repairs peripheral nerve injury: sensory nerve induces motor nerve regeneration.

    Science.gov (United States)

    Yu, Qing; Zhang, She-Hong; Wang, Tao; Peng, Feng; Han, Dong; Gu, Yu-Dong

    2017-10-01

    End-to-side neurorrhaphy is an option in the treatment of the long segment defects of a nerve. It involves suturing the distal stump of the disconnected nerve (recipient nerve) to the side of the intimate adjacent nerve (donor nerve). However, the motor-sensory specificity after end-to-side neurorrhaphy remains unclear. This study sought to evaluate whether cutaneous sensory nerve regeneration induces motor nerves after end-to-side neurorrhaphy. Thirty rats were randomized into three groups: (1) end-to-side neurorrhaphy using the ulnar nerve (mixed sensory and motor) as the donor nerve and the cutaneous antebrachii medialis nerve as the recipient nerve; (2) the sham group: ulnar nerve and cutaneous antebrachii medialis nerve were just exposed; and (3) the transected nerve group: cutaneous antebrachii medialis nerve was transected and the stumps were turned over and tied. At 5 months, acetylcholinesterase staining results showed that 34% ± 16% of the myelinated axons were stained in the end-to-side group, and none of the myelinated axons were stained in either the sham or transected nerve groups. Retrograde fluorescent tracing of spinal motor neurons and dorsal root ganglion showed the proportion of motor neurons from the cutaneous antebrachii medialis nerve of the end-to-side group was 21% ± 5%. In contrast, no motor neurons from the cutaneous antebrachii medialis nerve of the sham group and transected nerve group were found in the spinal cord segment. These results confirmed that motor neuron regeneration occurred after cutaneous nerve end-to-side neurorrhaphy.

  10. Small Engine Repair Modules (Workbook) = Reparacion de Motores Pequenos (Guia de Trabajo)

    Science.gov (United States)

    New York State Dept. of Correctional Services, Albany.

    This package contains an English-Language set of task procedure sheets dealing with small-engine repair and a Spanish translation of the same material. Addressed in the individual sections of the manual are the following aspects of engine tune-up, reconditioning, and troubleshooting: servicing air cleaners; cleaning gas tanks, fuel lines, and fuel…

  11. One-Step Cartilage Repair Technique as a Next Generation of Cell Therapy for Cartilage Defects: Biological Characteristics, Preclinical Application, Surgical Techniques, and Clinical Developments.

    Science.gov (United States)

    Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin

    2016-07-01

    To provide a comprehensive overview of the basic science rationale, surgical technique, and clinical outcomes of 1-step cartilage repair technique used as a treatment strategy for cartilage defects. A systematic review was performed in the main medical databases to evaluate the several studies concerning 1-step procedures for cartilage repair. The characteristics of cell-seed scaffolds, behavior of cells seeded into scaffolds, and surgical techniques were also discussed. Clinical outcomes and quality of repaired tissue were assessed using several standardized outcome assessment tools, magnetic resonance imaging scans, and biopsy histology. One-step cartilage repair could be divided into 2 types: chondrocyte-matrix complex (CMC) and autologous matrix-induced chondrogenesis (AMIC), both of which allow a simplified surgical approach. Studies with Level IV evidence have shown that 1-step cartilage repair techniques could significantly relieve symptoms and improve functional assessment (P studies clearly showed hyaline-like cartilage tissue in biopsy tissues by second-look arthroscopy. The 1-step cartilage repair technique, with its potential for effective, homogeneous distribution of chondrocytes and multipotent stem cells on the surface of the cartilage defect, is able to regenerate hyaline-like cartilage tissue, and it could be applied to cartilage repair by arthroscopy. Level IV, systematic review of Level II and IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Efficacy of bone marrow-stimulating technique in rotator cuff repair.

    Science.gov (United States)

    Bilsel, Kerem; Yildiz, Fatih; Kapicioglu, Mehmet; Uzer, Gokcer; Elmadag, Mehmet; Pulatkan, Anil; Esrefoglu, Mukaddes; Bozdag, Ergun; Milano, Giuseppe

    2017-08-01

    This study used a chronic rotator cuff (RC) tear model to investigate the effect of microfracture as a bone marrow-stimulating (BMS) technique for RC healing. A chronic retracted RC tendon tear model was created bilaterally in the subscapularis tendons of 20 New Zealand rabbits. The tendons were repaired after 8 weeks using a single-row configuration. Tendons in the right shoulder were repaired in standard fashion (control group). Microfractures were performed in the left shoulders before repair (microfracture group). The animals were euthanized 8 and 16 weeks after repair. The repaired tendons were tested biomechanically for their ultimate failure load, linear stiffness, and elongation at failure. Gross and histologic evaluations of the tendon-to-bone healing were evaluated. Macroscopically, subscapularis tendons were attached on the lesser tuberosity. In the microfracture group, collagen fibers were organized in relatively thicker bundles. The mean ultimate failure load of the microfracture group was significantly greater at 8 weeks (148.4 ± 31 N vs. 101.4 ± 26 N, respectively; P = .011) and 16 weeks (155 ± 30 N vs. 114.9 ± 25 N, respectively; P = .017) after repair. There were no significant differences between the groups for linear stiffness at 8 weeks (15.9 ± 2.7 N/mm vs. 15.8 ± 1.3 N/mm, respectively; P = .798) and 16 weeks (16.9 ± 4.3 N/mm vs. 17.1 ± 3.6 N/mm, respectively, P = .848) and elongation at failure at 8 weeks (4.7 ± 1.1 mm vs. 4.7 ± 1.3 mm, respectively; P = .848) and 16 weels (4.8 ± 1.5 mm vs. 4.9 ± 0.9 mm, respectively; P = .749). The microfracture on the tuberosity of the repaired chronic rotator cuff tear promoted dynamic tendon healing with significantly increased ultimate force to failure and with thicker collagen bundles and more fibrocartilage histologically at 8 weeks. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of

  13. The use of the Ma-Griffith technique for percutaneous repair of fresh ruptured tendo Achillis.

    Science.gov (United States)

    Klein, W; Lang, D M; Saleh, M

    1991-01-01

    All patients treated for a rupture of the Achilles tendon by the technique of percutaneous repair were identified from a five year period up to 1987. A review of the patients and results of this technique was undertaken using a clinical grading system. Review was conducted between 18 and 81 months following the injury. Of 38 patients followed up, 71% achieved good results and only 8% poor results. The re-rupture rate for this series was 8%. Sural nerve involvement (13%) was found to be a troublesome complication. During the period under study, a modification to the technique was introduced which abolished this complication. We present our results and describe the modification to the technique. The importance of the use of nonabsorbable sutures is emphasized.

  14. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair.

    Science.gov (United States)

    Kim, David H; Elattrache, Neal S; Tibone, James E; Jun, Bong-Jae; DeLaMora, Sergai N; Kvitne, Ronald S; Lee, Thay Q

    2006-03-01

    Reestablishment of the native footprint during rotator cuff repair has been suggested as an important criterion for optimizing healing potential and fixation strength. A double-row rotator cuff footprint repair will demonstrate superior biomechanical properties compared with a single-row repair. Controlled laboratory study. In 9 matched pairs of fresh-frozen cadaveric shoulders, the supraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique: 2 medial anchors with horizontal mattress sutures and 2 lateral anchors with simple sutures. The tendon from the contralateral shoulder was repaired using a single lateral row of 2 anchors with simple sutures. Each specimen underwent cyclic loading from 10 to 180 N for 200 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a video digitizing system; stiffness and failure load were determined from testing machine data. Gap formation for the double-row repair was significantly smaller (P row repair for the first cycle (1.67 +/- 0.75 mm vs 3.10 +/- 1.67 mm, respectively) and the last cycle (3.58 +/- 2.59 mm vs 7.64 +/- 3.74 mm, respectively). The initial strain over the footprint area for the double-row repair was nearly one third (P row repair. Adding a medial row of anchors increased the stiffness of the repair by 46% and the ultimate failure load by 48% (P row repair improved initial strength and stiffness and decreased gap formation and strain over the footprint when compared with a single-row repair. To achieve maximal initial fixation strength and minimal gap formation for rotator cuff repair, reconstructing the footprint attachment with 2 rows of suture anchors should be considered.

  15. Combined laparoscopic and open technique for repair of congenital abdominal hernia: A case report of prune belly syndrome.

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-10-01

    Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality.

  16. Data on electrical energy conservation using high efficiency motors for the confidence bounds using statistical techniques.

    Science.gov (United States)

    Shaikh, Muhammad Mujtaba; Memon, Abdul Jabbar; Hussain, Manzoor

    2016-09-01

    In this article, we describe details of the data used in the research paper "Confidence bounds for energy conservation in electric motors: An economical solution using statistical techniques" [1]. The data presented in this paper is intended to show benefits of high efficiency electric motors over the standard efficiency motors of similar rating in the industrial sector of Pakistan. We explain how the data was collected and then processed by means of formulas to show cost effectiveness of energy efficient motors in terms of three important parameters: annual energy saving, cost saving and payback periods. This data can be further used to construct confidence bounds for the parameters using statistical techniques as described in [1].

  17. Capstan screw rotator cuff repair: a novel two-row mini-open technique

    Science.gov (United States)

    Goubran, Alex; Jaques, Aishling; Smith, Christopher; Bunker, Tim

    2014-01-01

    Background Prospective data collection occurred between 2000 and 2010 on 143 consecutive patients with symptomatic rotator cuff tears, aiming to examine the end-result of a new technique of mini-open double row repair: the Capstan screw technique. Methods All patients had a pre- and postoperative Oxford Shoulder Score (OSS), American Shoulder and Elbow Surgeons (ASES) score and range of movement measurements. All were followed up for a minimum of 1 year with an exit questionnaire. Subscapularis repairs, small (5 cm) supraspinatus repairs were excluded. Ninety-nine patients fitted the inclusion and exclusion criteria of whom 87 had a complete data set. Results The mean (SD) pre-operative OSS was 21.85 (8.6) and the mean (SD) postoperative OSS was 44.58 (5.2) (p < 0.0001). The mean (SD) pre-operative ASES score was 51.5 (19.4) and the mean (SD) postoperative ASES score was 86.42 (17.06) (p < 0.0001). Flexion improved from a mean of 119° to 170° (p < 0.0001). The clinical re-tear rate was 3.4% and the imaged re-tear rate was 6.8%. In total, 91% of patients were satisfied with the procedure. There were no deep infections and two (2%) minor wound infections. There was no single instance of deltoid dysfunction. Conclusions The Capstan screw technique represents a simple, rapid, strong and reliable mini-open technique. PMID:27582933

  18. Cell biological and biomechanical evaluation of two different fixation techniques for rotator cuff repair.

    Science.gov (United States)

    Klinger, H-M; Koelling, S; Baums, M H; Kahl, E; Steckel, H; Smith, M M; Schultz, W; Miosge, N

    2009-06-01

    Our objective was to evaluate the cell biology and biomechanical aspects of the healing process after two different techniques in open rotator cuff surgery - double-loaded bio-absorbable suture anchors combined with so-called arthroscopic Mason-Allen stitches (AAMA) and a trans-osseous suture technique combined with traditional modified Mason-Allen stitches (SMMA). Thirty-six mature sheep were randomized into two repair groups. After 6, 12, or 26 weeks, evaluation of the reinsertion site of the infraspinatus tendon was performed. The mechanical load-to-failure and stiffness results did not indicate a significant difference between the two groups. After 26 weeks, fibrocartilage was sparse in the AAMA group, whereas the SMMA group showed the most pronounced amount of fibrocartilage. We found no ultrastructural differences in collagen fiber organization between the two groups. The relative expression of collagen type II mRNA in the normal group was 1.11. For the AAMA group, 6 weeks after surgery, the relative expression was 55.47, whereas for the SMMA group it was 1.90. This in vivo study showed that the AAMA group exhibited a tendon-to-bone healing process more favorable in its cell biology than that of the traditional SMMA technique. Therefore, the AAMA technique might also be more appropriate for arthroscopic repair.

  19. Evaluation of a New Knotless Suture Anchor Repair in Acute Achilles Tendon Ruptures: A Biomechanical Comparison of Three Techniques.

    Science.gov (United States)

    Cottom, James M; Baker, Joseph S; Richardson, Phillip E; Maker, Jared M

    Acute ruptures of the Achilles tendon are a common injury, and debate has continued in published studies on how best to treat these injuries. Specifically, controversy exists regarding the surgical approaches for Achilles tendon repair when one considers percutaneous versus open repair. The present study investigated the biomechanical strength of 3 different techniques for Achilles tendon repair in a cadaveric model. A total of 36 specimens were divided into 3 groups, each of which received a different construct. The first group received a traditional Krackow suture repair, the second group was repaired using a jig-assisted percutaneous suture, and the third group received a repair using a jig-assisted percutaneous repair modified with suture anchors placed into the calcaneus. The specimens were tested with cyclical loading and to ultimate failure. Cyclical loading showed a trend toward a stronger repair with the use of suture anchors after 10 cycles (p = .295), 500 cycles (p = .120), and 1000 cycles (p = .040). The ultimate load to failure was greatest in the group repaired with the modified knotless technique using the suture anchors (p = .098). The results of the present study show a clear trend toward a stronger construct in Achilles repair using a knotless suture anchor technique, which might translate to a faster return to activity and be more resistant to an early and aggressive rehabilitation protocol. Further clinical studies are warranted to evaluate this technique in a patient population. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique.

    Science.gov (United States)

    Lee, Kwang Won; Yang, Dae Suk; Lee, Gyu Sang; Ma, Chang Hyun; Choy, Won Sik

    2018-05-23

    This retrospective study compared the clinical and radiologic outcomes of patients who underwent arthroscopic rotator cuff repairs by the suture-bridge and double-row modified Mason-Allen techniques. From January 2012 to May 2013, 76 consecutive cases of full-thickness rotator cuff tear, 1 to 4 cm in the sagittal plane, for which arthroscopic rotator cuff repair was performed, were included. The suture-bridge technique was used in 37 consecutive shoulders; and the double-row modified Mason-Allen technique, in 39 consecutive shoulders. Clinical outcomes at a minimum of 2 years (mean, 35.7 months) were evaluated postoperatively using the visual analog scale; University of California, Los Angeles Shoulder Scale; American Shoulder and Elbow Surgeons Subjective Shoulder Scale; and Constant score. Postoperative cuff integrity was evaluated at a mean of 17.7 months by magnetic resonance imaging. At the final follow-up, the clinical outcomes improved in both groups (all P  .05). The retear rate was 18.9% in the shoulders subjected to suture-bridge repair and 12.8% in the double-row modified Mason-Allen group; the difference was not significant (P = .361). Despite the presence of fewer suture anchors, the patients who underwent double-row modified Mason-Allen repair had comparable shoulder functional outcomes and a comparable retear rate with those who underwent suture-bridge repair. Therefore, the double-row modified Mason-Allen repair technique can be considered an effective treatment for patients with medium- to large-sized full-thickness rotator cuff tears. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Training in the Motor Vehicle Repair and Sales Sector in the Grand Duchy of Luxembourg. Report for the FORCE Programme. First Edition.

    Science.gov (United States)

    Krier, Paul; Mathgen, Ted

    An international team of researchers studied the following aspects of training in Luxembourg's motor vehicle repair and sales sector: structure and characteristics; institutional and social context; relationship to Luxembourg's overall labor market; changing structural, economic, and organizational conditions; and training and recruitment and…

  2. New In-Field Composite Repair Techniques for Transmission or Distribution Pipelines

    Science.gov (United States)

    2009-05-18

    In-field repair of a damaged pipeline must be performed safely, efficiently, rapidly and reliably. Reinforcement of damaged pipelines is typically accomplished by welding a repair patch and then recoating the repaired area. The welded full-encircleme...

  3. Selected technological problems of repair of hydraulic drive systems for shearer loaders with the example of A2V-107 pumps and SHT-630W motors

    Energy Technology Data Exchange (ETDEWEB)

    Kusak, E.; Paluch, J.

    1983-07-01

    Major elements of hydraulic drive systems as well as their wear and repair characteristics are described. Types of wear and standardized repair methods are comparatively evaluated. The evaluations are aimed at development of standardized procedures for use in large repair shops. The following stages of repair operations of A2V-107 pumps and SHT-630W motors are analyzed: disassembling hydraulic systems, washing and cleaning, classification of equipment elements (elements for scrapping and for regeneration), regeneration, assembling and final tests. The following regeneration methods are discussed: cutting, burnishing, bushing (e.g. the Heli Coil method), regeneration using copper, tin or zinc dusts and a temperature from 950 to 1,000 K under inert atmosphere, heat treatments. Methods are reviewed for comparative evaluations of repair efficiency and repair quality as well as documents used for recording repair in the shops. Economic aspects of using standardized procedures for repair of hydraulic equipment for shearer loaders are discussed and recommendations are made. (6 refs.)

  4. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

    Science.gov (United States)

    Berezina, Tamara L; Fechtner, Robert D; Cohen, Amir; Kim, Eliott E; Chu, David S

    2015-01-01

    We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the right eye. Ahmed drainage device with sclera patch graft was implanted to control the intraocular pressure. Two years later the tube eroded through sclera graft and conjunctiva. Repair was performed by covering the tube with a corneal patch graft secured by tissue adhesive after the conjunctiva in this area was dissected away. The cornea graft was left uncovered due to fragility of adjacent conjunctiva. The healing of ocular and graft surfaces was complete prior to the 1 month follow-up. Conjunctival epithelium covered the corneal patch graft. At 12 months follow-up, the graft and the tube remained stable. Our report suggests that corneal patch graft fixation to the sclera by means of tissue adhesive, without closing the conjunctiva, can be considered as an effective alternative surgical approach for managing exposed glaucoma drainage tube, accompanied by adjacent conjunctiva tissue deficiency. How to cite this article: Berezina TL, Fechtner RD, Cohen A, Kim EE, Chu DS. New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case. J Curr Glaucoma Pract 2015;9(2):62-64.

  5. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  6. Robustness of movement detection techniques from motor execution

    DEFF Research Database (Denmark)

    Aliakbaryhosseinabadi, Susan; Jiang, Ning; Petrini, Laura

    2015-01-01

    subjects completed a set of movement executions prior to and following the oddball paradigm. The locality preserving projection followed by the linear discriminant analysis (LPP-LDA) and the matched-filter (MF) technique were applied offline for detection of movement. Results show that LPP...

  7. Direct surgical repair of spondylolysis in athletes: indications, techniques, and outcomes.

    Science.gov (United States)

    Drazin, Doniel; Shirzadi, Ali; Jeswani, Sunil; Ching, Harry; Rosner, Jack; Rasouli, Alexandre; Kim, Terrence; Pashman, Robert; Johnson, J Patrick

    2011-11-01

    Athletes present with back pain as a common symptom. Various sports involve repetitive hyperextension of the spine along with axial loading and appear to predispose athletes to the spinal pathology spondylolysis. Many athletes with acute back pain require nonsurgical treatment methods; however, persistent recurrent back pain may indicate degenerative disc disease or spondylolysis. Young athletes have a greater incidence of spondylolysis. Surgical solutions are many, and yet there are relatively few data in the literature on both the techniques and outcomes of spondylolytic repair in athletes. In this study, the authors undertook a review of the surgical techniques and outcomes in the treatment of symptomatic spondylolysis in athletes. A systematic review of the MEDLINE and PubMed databases was performed using the following key words to identify articles published between 1950 and 2011: "spondylolysis," "pars fracture," "repair," "athlete," and/or "sport." Papers on both athletes and nonathletes were included in the review. Articles were read for data on methodology (retrospective vs prospective), type of treatment, number of patients, mean patient age, and mean follow-up. Eighteen articles were included in the review. Eighty-four athletes and 279 nonathletes with a mean age of 20 and 21 years, respectively, composed the population under review. Most of the fractures occurred at L-5 in both patient groups, specifically 96% and 92%, respectively. The average follow-up period was 26 months for athletes and 86 months for nonathletes. According to the modified Henderson criteria, 84% (71 of 84) of the athletes returned to their sports activities. The time intervals until their return ranged from 5 to 12 months. For a young athlete with a symptomatic pars defect, any of the described techniques of repair would probably produce acceptable results. An appropriate preoperative workup is important. The ideal candidate is younger than 20 years with minimal or no listhesis and

  8. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  9. Motor Recovery and Synaptic Preservation after Ventral Root Avulsion and Repair with a Fibrin Sealant Derived from Snake Venom

    Science.gov (United States)

    Barbizan, Roberta; Castro, Mateus V.; Rodrigues, Antônio C.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2013-01-01

    Background Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. Methodology/Principal Findings Female Lewis rats (7 weeks old) were subjected to VRA and root replantation. The animals were divided into two groups: 1) avulsion only and 2) replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera). Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. Conclusions/Significance In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the astroglial reaction and

  10. Motor recovery and synaptic preservation after ventral root avulsion and repair with a fibrin sealant derived from snake venom.

    Directory of Open Access Journals (Sweden)

    Roberta Barbizan

    Full Text Available BACKGROUND: Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. METHODOLOGY/PRINCIPAL FINDINGS: Female Lewis rats (7 weeks old were subjected to VRA and root replantation. The animals were divided into two groups: 1 avulsion only and 2 replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera. Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. CONCLUSIONS/SIGNIFICANCE: In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the

  11. Sensorless AC electric motor control robust advanced design techniques and applications

    CERN Document Server

    Glumineau, Alain

    2015-01-01

    This monograph shows the reader how to avoid the burdens of sensor cost, reduced internal physical space, and system complexity in the control of AC motors. Many applications fields—electric vehicles, wind- and wave-energy converters and robotics, among them—will benefit. Sensorless AC Electric Motor Control describes the elimination of physical sensors and their replacement with observers, i.e., software sensors. Robustness is introduced to overcome problems associated with the unavoidable imperfection of knowledge of machine parameters—resistance, inertia, and so on—encountered in real systems. The details of a large number of speed- and/or position-sensorless ideas for different types of permanent-magnet synchronous motors and induction motors are presented along with several novel observer designs for electrical machines. Control strategies are developed using high-order, sliding-mode and quasi-continuous-sliding-mode techniques and two types of observer–controller schemes based on backstepping ...

  12. Performance of evaluation techniques for planning preventive repair of leakages on BWR vessel stub tubes

    International Nuclear Information System (INIS)

    Prat, J.P.

    1985-01-01

    Stub tubes have been installed on the control rod drive assemblies of the majority of boiling water reactor vessel bottoms. These stub tubes can undergo a slow process of cracking, producing no potential hazard but occasional plant unavailability due to leakage in excess of specification limits. In the case considered here, the development and application of remotely controlled equipment permitting access both from inside and outside the housing, and of crack evolution and location techniques, has made the progressive development, selection and planning of repairs a possibility, thus minimizing the risk of leakages appearing between refuelling outages. The example used here is of a Nuclear Power Plant in which a first leak appeared in 1981. Since that time extensive and progressive laboratory and field development work has been carried out. This paper presents the experience gained with customized, remote-control inspection equipment, and several developed or adapted techniques, as the basis for an in-service repair decision tree, the case in question being that of a BWR plant in which a cracking process, not affecting safety but potentially affecting availability, has given rise to leaks after ten years of operation

  13. Novel Repair Technique for Life-Extension of Hydraulic Turbine Components in Hydroelectric Power Stations

    Science.gov (United States)

    Hiramatsu, Yoichi; Ishii, Jun; Funato, Kazuhiro

    A significant number of hydraulic turbines operated in Japan were installed in the first half of the 20th century. Today, aging degradation and flaws are observed in these turbine equipments. So far, Japanese engineers have applied NDI technology of Ultrasonic Testing (UT) to detect the flaws, and after empirical evaluation of the remaining life they decided an adequate moment to replace the equipments. Since the replacement requires a large-scale field site works and high-cost, one of the solutions for life-extension of the equipments is introduction of repair services. We have been working in order to enhance the accuracy of results during the detection of flaws and flaws dimensioning, in particular focusing on the techniques of Tip-echo, TOFD and Phased-Array UT, accompanied by the conventional UT. These NDI methods made possible to recognize the entire image of surface and embedded flaws with complicated geometry. Then, we have developed an evaluation system of these flaws based on the theory of crack propagation, of the logic of crack growth driven by the stress-intensity factor of the crack tip front. The sophisticated evaluation system is constituted by a hand-made software and database of stress-intensity factor. Based on these elemental technologies, we propose a technique of repair welding to provide a life-extension of hydraulic turbine components.

  14. Short-term outcome after Onstep versus Lichtenstein technique for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, K; Burcharth, J; Fonnes, S

    2015-01-01

    was to investigate if there were differences in early postoperative pain during the first 10 days between the Onstep and the Lichtenstein technique. METHODS: This was a double-blinded, randomized clinical trial conducted in five surgical departments in Denmark, from April 2013 to June 2014. Eligible participants...... for this study were male patients, >18 years, with a primary inguinal hernia. Experimental treatment in this study was the Onstep technique, which was compared with the Lichtenstein repair. Primary outcome was postoperative pain during the first 10 days following surgery. Secondary outcomes included duration...... of surgery, period for return to normal daily activities (days), and recurrence. Randomization was done in blocks and stratified on centers. Participants and study personnel handling questionnaires and analysis were blinded to the allocation. RESULTS: In total, 290 participants were randomized. We found...

  15. The Tilburg double blind randomised controlled trial comparing inguinal hernia repair according to Lichtenstein and the transinguinal preperitoneal technique

    Directory of Open Access Journals (Sweden)

    Gerritsen Pieter G

    2009-09-01

    Full Text Available Abstract Background Anterior open treatment of the inguinal hernia with a tension free mesh has reduced the incidence of recurrence and direct postoperative pain. The Lichtenstein procedure rules nowadays as reference technique for hernia treatment. Not recurrences but chronic pain is the main postoperative complication in inguinal hernia repair after Lichtenstein's technique. Preliminary experiences with a soft mesh placed in the preperitoneal space showed good results and less chronic pain. Methods The TULIP is a double-blind randomised controlled trial in which 300 patients will be randomly allocated to anterior inguinal hernia repair according to Lichtenstein or the transinguinal preperitoneal technique with soft mesh. All unilateral primary inguinal hernia patients eligible for operation who meet inclusion criteria will be invited to participate in this trial. The primary endpoint will be direct postoperative- and chronic pain. Secondary endpoints are operation time, postoperative complications, hospital stay, costs, return to daily activities (e.g. work and recurrence. Both groups will be evaluated. Success rate of hernia repair and complications will be measured as safeguard for quality. To demonstrate that inguinal hernia repair according to the transinguinal preperitoneal (TIPP technique reduces postoperative pain to Discussion The TULIP trial is aimed to show a reduction in postoperative chronic pain after anterior hernia repair according to the transinguinal preperitoneal (TIPP technique, compared to Lichtenstein. In our hypothesis the TIPP technique reduces chronic pain compared to Lichtenstein. Trial registration ISRCTN 93798494

  16. Simultaneous demonstration of UV-type and ionizing radiation-type DNA repair by the nucleoid sedimentation technique

    International Nuclear Information System (INIS)

    Aldenhoff, P.; Sperling, K.

    1984-01-01

    The nucleoid sedimentation technique is one of the most sensitive methods for measuring DNA excision repair. With this technique, it is shown that both UV- and ionizing radiation-type repair (the latter induced by bleomycin) can be discriminated in HeLa and normal diploid cells using 1-β-D-arabinofuranosylcytosine. The latter compound inhibits UV-type repair synthesis, and thus causes DNA breaks due to enzymic incision to persist, but has no effect on rejoining DNA after ionizing radiation-type damage. It was then possible to prove that 4-nitroquinoline-1-oxide induces both types of lesions which are repaired simultaneously. This effect could be demonstrated in HeLa and normal human diploid cells in a single experimental set-up. (Auth.)

  17. Impingement syndrome of the shoulder following double row suture anchor technique for arthroscopic rotator cuff repair: a case report

    Directory of Open Access Journals (Sweden)

    Rambani Rohit

    2009-06-01

    Full Text Available Abstract Introduction Arthroscopic repair of the rotator cuff is a demanding surgery. Accurate placement of anchors is key to success. Case presentation A 38-year-old woman received arthroscopic repair of her rotator cuff using a double row suture anchor technique. Postoperatively, she developed impingement syndrome which resulted from vertical displacement of a suture anchor once the shoulder was mobilised. The anchor was removed eight weeks following initial surgery and the patient had an uneventful recovery. Conclusion Impingement syndrome following arthroscopic repair of the rotator cuffs using double row suture anchor has not been widely reported. This is the first such case where anchoring has resulted in impingement syndrome.

  18. Evaluation of the functional results after rotator cuff arthroscopic repair with the suture bridge technique

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic treatment of large and extensive rotator cuff injuries (RCI that involved the supra and infraspinatus muscles using the suture bridge (SB technique. METHODS: Between July 2010 and November 2014, 37 patients with RCI who were treated with SB technique were evaluated. The study included all patients with a minimum follow-up of 12 months who underwent primary surgery of the shoulder. Twenty-four patients were male and 13 were female. The mean age was 60 years (45-75. The dominant side was affected in 32 cases. The most common cause of injury was trauma (18 cases. The mean preoperative motion was 123°, 58°, T11. Through magnetic resonance imaging, 36 fatty degenerations were classified according to Goutallier. Patients underwent rotator cuff repair with SB technique, which consists of using a medial row anchor with two Corkscrew(r fibertape(r or fiberwire(r at the articular margin, associated with lateral fixation without stitch using PushLocks(r or SwiveLocks(r. RESULTS: The mean age was 60 years and mean fatty degeneration was 2.6. The mean range of motion (following the AAOS in the postoperative evaluation was 148° of forward elevation, 55° in lateral rotation and medial rotation in T9. Using the criteria of the University of California at Los Angeles (UCLA, 35 (94% patients had excellent and good results; one (2.7%, fair; and one (2.7%, poor. CONCLUSION: Arthroscopic repair of a large and extensive RCI using SB technique had good and excellent results in 94% of the patients.

  19. Electrical stimulation of paralyzed vibrissal muscles reduces endplate reinnervation and does not promote motor recovery after facial nerve repair in rats.

    Science.gov (United States)

    Sinis, Nektarios; Horn, Frauke; Genchev, Borislav; Skouras, Emmanouil; Merkel, Daniel; Angelova, Srebrina K; Kaidoglou, Katerina; Michael, Joern; Pavlov, Stoyan; Igelmund, Peter; Schaller, Hans-Eberhard; Irintchev, Andrey; Dunlop, Sarah A; Angelov, Doychin N

    2009-10-01

    The outcome of peripheral nerve injuries requiring surgical repair is poor. Recent work has suggested that electrical stimulation (ES) of denervated muscles could be beneficial. Here we tested whether ES has a positive influence on functional recovery after injury and surgical repair of the facial nerve. Outcomes at 2 months were compared to animals receiving sham stimulation (SS). Starting on the first day after end-to-end suture (facial-facial anastomosis), electrical stimulation (square 0.1 ms pulses at 5 Hz at an ex tempore established threshold amplitude of between 3.0 and 5.0V) was delivered to the vibrissal muscles for 5 min a day, 3 times a week. Restoration of vibrissal motor performance following ES or SS was evaluated using the video-based motion analysis and correlated with the degree of collateral axonal branching at the lesion site, the number of motor endplates in the target musculature and the quality of their reinnervation, i.e. the degree of mono- versus poly-innervation. Neither protocol reduced collateral branching. ES did not improve functional outcome, but rather reduced the number of innervated motor endplates to approximately one-fifth of normal values and failed to reduce the proportion of poly-innervated motor endplates. We conclude that ES is not beneficial for recovery of whisker function after facial nerve repair in rats.

  20. The success of 6-hour hospital discharge on patients having vaginal repair operations using a new conscious sedation technique.

    Science.gov (United States)

    Hill, N; Gupta, A; Zakaryan, A; Morey, R

    2011-01-01

    Anterior and posterior repair are standard surgical techniques for treatment of vaginal prolapse. These procedures are performed traditionally under general anaesthetic or spinal anaesthetic and usually require overnight admission in the hospital. We describe our case series of 40 patients who underwent anterior (18/40), posterior (20/40) or combined repair (2/40) under local anaesthetic and conscious sedation (Remifentanyl). The majority (35/40) were performed in the day-case surgery unit and 95% patients were discharged within 6 hours of the operation, with no complications. All the patients were satisfied with the anaesthetic technique. We concluded that our technique of vaginal repair avoids the risk of general and spinal anaesthetic. The majority of operations can be performed as day cases with good patient satisfaction and without increasing risks to the patients. This technique has potential significant financial saving for the hospitals.

  1. Difficulties and Problematic Steps in Teaching the Onstep Technique for Inguinal Hernia Repair, Results from a Focus Group Interview

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Laursen, Jannie; Rosenberg, Jacob

    2016-01-01

    technique for inguinal hernia repair, seen from the instructor's point of view. Methods. We designed a qualitative study using a focus group to allow participants to elaborate freely and facilitate a discussion. Participants were surgeons with extensive experience in performing the Onstep technique from...... course should preferably have experience with other types of hernia repairs. If trainees are inexperienced, the training setup should be a traditional step-by-step programme. A training setup should consist of an explanation of the technique with emphasis on anatomy and difficult parts of the procedure...

  2. [STUDY ON WOUND HEALING AFTER Sommerlad TECHNIQUE REPAIR OF ISOLATED CLEFT PALATE].

    Science.gov (United States)

    Lu, Yong; Shi, Bing; Wang, Zhiyong; Zhan, Xin

    2014-07-01

    To study the inhibitory effect of Sommerlad technique on the growth of the maxilla by comparing the wound healing between Sommerlad and Von Langenbeck techniques in repair of isolated cleft palate. A retrospective cohort study was conducted on 54 patients with isolated cleft palate who received palatoplasty with levator veli palatini retropositioning according to Sommerlad between June 2005 and August 2011 as trial group; 89 cleft patients received Von Langenbeck technique repair between June 2003 and September 2006 as control group. There was no significant difference in gender and age between 2 groups (P > 0.05). The operation time, intraoperative blood loss, body temperature, and fever were recorded and compared; the wound healing was observed, and the palatal mucosa was graded according to Karsten standard. The operation time of trial group [(72.2 ± 5.5) minutes] was significantly longer than that of control group [(58.1 ± 6.8) minutes] (t = 4.494, P = 0.000); the intraoperative blood loss of trial group [(18.6 ± 6.5) mL] was significantly less than that of control group [(34.2 ± 10.2) mL] (t = 2.447, P = 0.000). Within postoperative 48 hours, the highest body temperature was 36.6-37.6°C (mean, 36.9°C) in trial group, and was 36.8-38.2°C (mean, 37.3°C) in control group; fever occurred in 5 patients (9.3%) of trial group and 21 patients (23.6%) of control group, showing significant difference (χ2 = 4.640, P = 0.030). The patients were followed up 3-18 months (mean, 9 months) in the trial group, and 3-6 years (mean, 4 years) in the control group. Scar was rated as level 0, level 1, and level 2 in 38, 13, and 3 cases of trial group, and in 6, 35, and 48 cases of control group, showing significant difference (Z = -7.785, P = 0.000). The isolated cleft palate repair using Sommerlad technique has the advantages of less injury and less scar tissue, indicating no inhibitory effect on the growth of the maxilla.

  3. [PART-KESSLER TECHNIQUE WITH SUTURE ANCHOR IN REPAIR OF SPONTANEOUS Achilles TENDON RUPTURE].

    Science.gov (United States)

    Qi, Jie; Duan, Liang; Li, Weiwei; Wei, Wenbo

    2016-02-01

    To summarize the application and experience of repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor. Between January 2011 and December 2013, 31 patients with spontaneous Achilles tendon rupture were treated by part-Kessler technique with suture anchor. Of 31 cases, 23 were male and 8 were female, aged 16-53 years (mean, 38 years). The left side was involved in 15 cases and the right side in 16 cases. The causes of injury included sudden heel pain and walking weakness during sports in 22 cases; no surefooted down-stairs, slip, and carrying heavy loads in 9 cases. The distance from broken site to the calcaneus adhension of Achilles tendon was 3-6 cm (mean, 4.2 cm). The time from injury to operation was 7 hours to 4 days (mean, 36.8 hours). All incisions healed by first intention without nerve injury or adhering with skin. The patients were followed up 6-24 months (mean, 15 months). All patients could complete 25 times heel raising without difficulty at 6 months after operation. No Achilles tendon rupture occurred again during follow-up. At 6 months after operation, the range of motion of the ankle joint in dorsiflexion and plantar flexion showed no significant difference between normal and affected sides (t=0.648, P=0.525; t=0.524, P=0.605). The circumference of the affected leg was significantly smaller than that of normal leg at 6 months after operation (t=2.074, P=0.041), but no significant difference was found between affected and normal sides at 12 months after operation (t=0.905, P=0.426). The American Orthopedic Foot and Ankle Society (AOFAS) scores at 6, 12, 18, and 24 months after operation were significantly higher than preoperative score (P0.05). Repairing spontaneous Achilles tendon rupture by part-Kessler technique with suture anchor can supply strong strain and decrease the shear forces of suture. So part-Kessler technique with suture anchor is successful in repairing spontaneous Achilles tendon rupture.

  4. Mechanical cough augmentation techniques in amyotrophic lateral sclerosis/motor neuron disease

    OpenAIRE

    Rafiq, M.K.; Bradburn, M.; Mustfa, N.; Mcdermott, C.J.; Annane, D.

    2016-01-01

    © 2016 The Cochrane Collaboration.This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: To assess the effects of mechanical insufflator/exsufflator (MI-E) and the breath-stacking technique for reducing morbidity and mortality and enhancing quality of life in people with amyotrophic lateral sclerosis (ALS)/motor neuron disease (MND).

  5. All-inside arthroscopic lateral collateral ligament repair for ankle instability with a knotless suture anchor technique.

    Science.gov (United States)

    Vega, Jordi; Golanó, Pau; Pellegrino, Alexandro; Rabat, Eduard; Peña, Fernando

    2013-12-01

    Recently, arthroscopic-assisted techniques have been described to treat lateral ankle instability with excellent results. However, complications including neuritis of the superficial peroneal or sural nerve, and pain or discomfort due to a prominent anchor or suture knot have been reported. The aim of this study was to describe a novel technique, the "all-inside arthroscopic lateral collateral ankle ligament repair," and its results for treating patients with ankle instability. Sixteen patients (10 men and 6 women, mean age 29.3 years, 17-46) with lateral ankle instability were treated with an arthroscopic procedure. Using a suture passer and a knotless anchor, the ligaments were repaired with an all-inside technique. The right ankle was affected in 10 cases. Mean follow-up was 22.3 (12-35) months. On arthroscopic examination, 13 patients had an isolated anterior talofibular ligament (ATFL) injury, and in 3 patients, both the ATFL and calcaneofibular ligament (CFL) were affected. All-inside arthroscopic anatomic repair of the lateral collateral ligament complex was performed in all cases. All patients reported subjective improvement of their ankle instability. The mean AOFAS score increased from 67 preoperatively to 97 at final follow-up. No major complications were reported. The all-inside arthroscopic ligament repair was a safe, reliable, and reproducible technique that both provided an anatomic repair of the lateral collateral ligament complex and restored ankle stability while preserving all the advantages of an arthroscopic technique. Level IV, retrospective case series.

  6. Laparoscopic inguinal preperitoneal injection--novel technique for inguinal hernia repair: preliminary results of experimental study.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Rasputin, Andrey; Podkamenev, Alexey; Krasnov, Pavel; Weber, Irina; Solovjev, Alexey

    2012-04-01

    Inguinal hernia repair is the most common procedure in pediatric surgery. Suture techniques for laparoscopic inguinal hernia repair in children are easy to perform and popular with a low recurrence rate. The aim of this study was to evaluate the effect of laparoscopic preperitoneal injection of three-dimensional gel on closing of the inguinal hernia sac (IHS) in laboratory animals. With the animals under general anesthesia, we performed peritoneoscopy in 12 male Chinchilla rabbits weighing 1200-1400 g. The endoscope was introduced into the abdominal cavity, and bilateral deep inguinal rings were identified. A Tuohy needle with the injectable polymeric bulking agent DAM+™ (three-dimensional polyacrylamide gel with silver ions [Argiform(®) from Bioform(®)]) was introduced preperitoneally. The implant was then injected across the entire orifice of the deep inguinal rings and draped over the cord structures. After completion of bilateral repairs, the rabbits were extubated and observed in the animal laboratory. Then the second laparoscopy was performed 6 months later, and the deep inguinal rings were inspected. The postoperative course was uneventful in all the animals. At the second laparoscopy no reopening of the entire orifice of the deep inguinal rings was noted. Accurate placement of the polymeric agent and adequate coverage of the vas deferens were accomplished in all the animals. This study demonstrates that the biopolymeric implant gives good postoperative results and a stable trend of closing the IHS in long-term follow-up. In conclusion, we hope that injectable polymeric bulking agents can be used for treatment of inguinal hernias of pediatric patients after additional animal and human research.

  7. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    Science.gov (United States)

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  8. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair.

    Science.gov (United States)

    Burkhart, Stephen S; Adams, Christopher R; Burkhart, Sarah S; Schoolfield, John D

    2009-03-01

    The purpose of this study was to compare the biomechanical fixation parameters of a standard double-row rotator cuff repair with those of a knotless footprint reconstruction using the double-row SwiveLock-FiberChain technique (Arthrex, Naples, FL). Seven matched pairs of human cadaveric shoulders were used for testing (mean age, 48 +/- 10.3 years). A shoulder from each matched pair was randomly selected to receive a standard 4-anchor double-row repair of the supraspinatus tendon, and the contralateral shoulder received a 4-anchor double-row SwiveLock-FiberChain repair. The tendon was cycled from 10 N to 100 N at 1 Hz for 500 cycles, followed by a single-cycle pull to failure at 33 mm/s. Yield load, ultimate load, cyclic displacement, and mode of failure were recorded. Yield load and ultimate load were higher for the SwiveLock-FiberChain repair compared with the standard double-row repair for 6 of the 7 treatment pairs; however, 1 cadaver had a contrary outcome, so the overall mean differences in yield load and ultimate load were not significantly different from 0 by Student t test (P > .15). Furthermore, smaller differences between yield load and ultimate load for the SwiveLock-FiberChain repair in 5 of the 7 treatment pairs showed a self-reinforcing mechanism. Double-row footprint reconstruction with the knotless SwiveLock-FiberChain system in this study had yield loads, ultimate loads, and cyclic displacements that were statistically equivalent to those of standard double-row rotation cuff reconstructions. The SwiveLock-FiberChain system's combination of strength, self-reinforcement, and decreased operating time may offer advantages to the surgeon, particularly when dealing with older patients in whom poor tissue quality and total operative time are important considerations.

  9. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  10. [Motor capacities involved in the psychomotor skills of the cardiopulmonary resuscitation technique: recommendations for the teaching-learning process].

    Science.gov (United States)

    Miyadahira, A M

    2001-12-01

    It is a bibliographic study about the identification of the motor capacities involved in the psychomotor skills of the cardiopulmonary resuscitation (CPR) which aims to obtain subsidies to the planning of the teaching-learning process of this skill. It was found that: the motor capacities involved in the psychomotor skill of the CPR technique are predominantly cognitive and motor, involving 9 perceptive-motor capacities and 8 physical proficiency capacities. The CPR technique is a psychomotor skill classified as open, done in series and categorized as a thin and global skill and the teaching-learning process of the CPR technique has an elevated degree of complexity.

  11. Recurrent tricuspid insufficiency: is the surgical repair technique a risk factor?

    Science.gov (United States)

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair. In our clinic, 93 patients with functional tricuspid insufficiency underwent surgical tricuspid repair from May 2007 through October 2010. The study was retrospective, and all the data pertaining to the patients were retrieved from hospital records. Functional capacity, recurrent tricuspid insufficiency, and risk factors aggravating the insufficiency were analyzed for each patient. In the medium term (25.4 ± 10.3 mo), the rates of grades 3 and 4 tricuspid insufficiency in the De Vega, modified De Vega, and ring annuloplasty groups were 31%, 23.1%, and 6.1%, respectively. Logistic regression analysis revealed that chronic obstructive pulmonary disease, left ventricular dysfunction (ejection fraction, tricuspid insufficiency. Medium-term survival was 90.6% for the De Vega group, 96.3% for the modified De Vega group, and 97.1% for the ring annuloplasty group. Ring annuloplasty provided the best relief from recurrent tricuspid insufficiency when compared with DeVega annuloplasty. Modified De Vega annuloplasty might be a suitable alternative to ring annuloplasty when rings are not available.

  12. Fabrication of a two-level tumor bone repair biomaterial based on a rapid prototyping technique

    Energy Technology Data Exchange (ETDEWEB)

    Kai He; Yan Yongnian; Zhang Renji; Wang Xiaohong [Key Laboratory for Advanced Materials Processing Technology, Ministry of Education and Center of Organ Manufacturing, Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Wang Xinluan; Madhukar, Kumta Shekhar; Qin Ling [Department of Orthoapedics and Traumatology, The Chinese University of Hong Kong. Shatin, NT (Hong Kong)], E-mail: wangxiaohong@tsinghua.edu.cn, E-mail: kumta@cuhk.edu.hk, E-mail: qin@ort.cuhk.edu.hk

    2009-06-01

    After the removal of the giant cell tumor (GCT) of bone, it is necessary to fill the defects with adequate biomaterials. A new functional bone repair material with both stimulating osteoblast growth and inhibiting osteoclast activity has been developed with phosphorylated chitosan (P-chitosan) and disodium (1 {yields} 4)-2-deoxy-2-sulfoamino-{beta}-D-glucopyranuronan (S-chitosan) as the additives of poly(lactic acid-co-glycolic acid) (PLGA)/calcium phosphate (TCP) scaffolds based on a double-nozzle low-temperature deposition manufacturing technique. A computer-assisted design model was used and the optimal fabrication parameters were determined through the manipulation of a pure PLGA/TCP system. The microscopic structures, water absorbability and mechanical properties of the samples with different P-chitosan and S-chitosan concentrations were characterized correspondingly. The results suggested that this unique composite porous scaffold material is a potential candidate for the repair of large bone defects after a surgical removal of GCT.

  13. Sphenoid dysplasia in neurofibromatosis type 1: a new technique for repair.

    Science.gov (United States)

    Concezio, Di Rocco; Amir, Samii; Gianpiero, Tamburrini; Luca, Massimi; Mario, Giordano

    2017-06-01

    Sphenoid bone dysplasia in neurofibromatosis type 1 is characterized by progressive exophthalmos and facial disfiguration secondary to herniation of meningeal and cerebral structures. We describe a technique for reconstruction of the sphenoid defect apt at preventing or correcting the ocular globe dislocation. After placement of spinal cerebrospinal fluid drainage to reduce intracranial pressure, the temporal pole is posteriorly dislocated extradurally. The greater sphenoid wing defect is identified. A titanium mesh covered by lyophilized dura, modeled in a curved fashion, is interposed between the bone defect and the cerebro-meningeal structures with its convex surface over the retracted temporal pole. The particular configuration of the titanium mesh allows a self-maintaining position due to the pressure exerted by the brain over its convex central part with its lateral margins consequently pushed and self-anchored against the medial and lateral walls of the temporal fossa. Screw fixation is not needed. The technique utilized in four cases proved to be reliable at the long-term clinical and neuroradiological controls (6 to 19 years). Sphenoid bone dysplasia in NF1, resulting in proptosis and exophthalmos, is usually progressive. It can be surgically repaired using a curved titanium mesh with the convexity faced to the temporal pole that is in the opposite fashion from all the techniques previously introduced. When utilized early in life, the technique can prevent the occurrence of the orbital and facial disfiguration.

  14. Advanced analysis technique for the evaluation of linear alternators and linear motors

    Science.gov (United States)

    Holliday, Jeffrey C.

    1995-01-01

    A method for the mathematical analysis of linear alternator and linear motor devices and designs is described, and an example of its use is included. The technique seeks to surpass other methods of analysis by including more rigorous treatment of phenomena normally omitted or coarsely approximated such as eddy braking, non-linear material properties, and power losses generated within structures surrounding the device. The technique is broadly applicable to linear alternators and linear motors involving iron yoke structures and moving permanent magnets. The technique involves the application of Amperian current equivalents to the modeling of the moving permanent magnet components within a finite element formulation. The resulting steady state and transient mode field solutions can simultaneously account for the moving and static field sources within and around the device.

  15. The "Batman flap": a novel technique to repair a large central glabellar defect.

    Science.gov (United States)

    Puviani, Mario; Curci, Marco

    2018-04-01

    Given the critical position of central glabella among the frontal, nasal, and supraorbital aesthetic subunits of the face, the reconstruction of large defects in this area represents a surgical challenge. We describe a surgical technique based on a modified, curved, A-T flap to repair a large glabellar defect. Our modification is useful for large glabellar defects because it enables the distribution of the tension all over the reconstruction sides, avoiding a stressed central area and the subsequent risk of necrosis; functionally, it respects the eyebrows position and since the advancement is parallel to their major axes, it avoids the reduction of the distance between them. The "Batman flap" enables reconstructing a glabellar defect, with a good aesthetical result and the respect of the relevant aesthetical subunits. © 2017 The International Society of Dermatology.

  16. Ultrasonic techniques for repair of aircraft structures with bonded composite patches

    Science.gov (United States)

    Smith, S. H.; Senapati, N.; Francini, R. B.

    1994-01-01

    This is a paper on a research and development project to demonstrate a novel ultrasonic process for the field application of boron/epoxy (B/Ep) patches for repair of aircraft structures. The first phase of the project was on process optimization and testing to develop the most practical ultrasonic processing techniques. Accelerated testing and aging behavior of precured B/Ep patches, which were ultrasonically bonded to simulated B-52 wing panel assemblies, were performed by conducting flight-by-flight spectrum loading fatigue tests. The spectrum represented 2340 missions/flights or 30 years of service. The effects of steady-state applied temperature and prior exposure of the B/Ep composite patches were evaluated. Representative experimental results of this phase of the project are presented.

  17. Use of an extracapsular stabilization technique to repair cruciate ligament ruptures in two avian species.

    Science.gov (United States)

    Chinnadurai, Sathya K; Spodnick, Gary; Degernes, Laurel; DeVoe, Ryan S; Marcellin-Little, Denis J

    2009-12-01

    An extracapsular stabilization technique was used to repair cruciate ligament ruptures in a trumpeter hornbill (Bycanistes bucinator) and an African grey parrot (Psittacus erithacus). The hornbill demonstrated cranial drawer motion and severe rotational instability of the stifle from ruptures of the cranial and caudal cruciate ligaments and stifle joint capsule. The luxation was reduced, and the fibula was cranially transposed, in relation to the tibiotarsus, and anchored with 2 positive profile threaded acrylic pins. A lateral extracapsular stabilization was then performed. The African grey parrot had a traumatic stifle luxation, and an open reduction and a lateral extracapsular stabilization were performed. Both birds regained function of the affected leg by 1 month after surgery. Extracapsular stabilization allows motion of the stifle joint to be maintained during the postoperative recovery period, an advantage over rigid stabilization. Maintaining motion in the stifle joint facilitates physical therapy and can aid in full recovery after avian stifle injuries.

  18. Large-signal analysis of DC motor drive system using state-space averaging technique

    International Nuclear Information System (INIS)

    Bekir Yildiz, Ali

    2008-01-01

    The analysis of a separately excited DC motor driven by DC-DC converter is realized by using state-space averaging technique. Firstly, a general and unified large-signal averaged circuit model for DC-DC converters is given. The method converts power electronic systems, which are periodic time-variant because of their switching operation, to unified and time independent systems. Using the averaged circuit model enables us to combine the different topologies of converters. Thus, all analysis and design processes about DC motor can be easily realized by using the unified averaged model which is valid during whole period. Some large-signal variations such as speed and current relating to DC motor, steady-state analysis, large-signal and small-signal transfer functions are easily obtained by using the averaged circuit model

  19. Complications after pectus excavatum repair using pectus bars in adolescents and adults: risk comparisons between age and technique groups.

    Science.gov (United States)

    Choi, Soohwan; Park, Hyung Joo

    2017-10-01

    To compare the complications associated with age and technique groups in patients undergoing pectus excavatum (PE) repair. The data of 994 patients who underwent PE repair from March 2011 to December 2015 were retrospectively reviewed. Mean age was 9.59 years (range 31 months-55 years), and 756 patients were men (76.1%). The age groups were defined as follows: Group 1, Group 2, 5-9 years; Group 3, 10-14 years; Group 4, 15-17 years; Group 5, 18-19 years; Group 6, 20-24 years; and Group 7, >24 years. The technique groups were defined as follows: Group 1, patients who underwent repair with claw fixators and hinge plates; Group 2, patients who underwent repair with our 'bridge' technique. Complications were compared between age groups and technique groups. No cases of mortality occurred. Complication rates in the age groups 1-7 were 5.4%, 3.6%, 12.1%, 18.2%, 17.3%, 13.9% and 16.7%, respectively. The complication rate tripled after the age of 10. In multivariable analysis, odds ratio of Groups 4, 5 and 7 and asymmetric types were 3.04, 2.81, 2.97 and 1.70 (P Group 1 was 0.8% (6 of 780). No bar dislocations occurred in technique Group 2. Older patients have more asymmetric pectus deformity and they are also risk factors for complications following PE repair. The bridge technique provides a bar dislocation rate of 0%, even in adult patients. This procedure seems to reduce or prevent major complications following PE repair. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Development and validation of predictive simulation model of multi-layer repair welding process by temper bead technique

    International Nuclear Information System (INIS)

    Okano, Shigetaka; Miyasaka, Fumikazu; Mochizuki, Masahito; Tanaka, Manabu

    2015-01-01

    Stress corrosion cracking (SCC) has recently been observed in the nickel base alloy weld metal of dissimilar pipe joint used in pressurized water reactor (PWR) . Temper bead technique has been developed as one of repair procedures against SCC applicable in case that post weld heat treatment (PWHT) is difficult to carry out. In this regard, however it is essential to pass the property and performance qualification test to confirm the effect of tempering on the mechanical properties at repair welds before temper bead technique is actually used in practice. Thus the appropriate welding procedure conditions in temper bead technique are determined on the basis of the property and performance qualification testing. It is necessary for certifying the structural soundness and reliability at repair welds but takes a lot of work and time in the present circumstances. Therefore it is desirable to establish the reasonable alternatives for qualifying the property and performance at repair welds. In this study, mathematical modeling and numerical simulation procedures were developed for predicting weld bead configuration and temperature distribution during multi-layer repair welding process by temper bead technique. In the developed simulation technique, characteristics of heat source in temper bead welding are calculated from weld heat input conditions through the arc plasma simulation and then weld bead configuration and temperature distribution during temper bead welding are calculated from characteristics of heat source obtained through the coupling analysis between bead surface shape and thermal conduction. The simulation results were compared with the experimental results under the same welding heat input conditions. As the results, the bead surface shape and temperature distribution, such as A cl lines, were in good agreement between simulation and experimental results. It was concluded that the developed simulation technique has the potential to become useful for

  1. Features of kinematic structure of motor actions technique in the freestyle wrestlers with different qualification

    Directory of Open Access Journals (Sweden)

    Tupeev Y.V.

    2010-02-01

    Full Text Available The sequence of educational steps in teaching basic technique elements in stance for young wrestlers at the initial training stage was determined by the expert assessment method. The biomechanical features of technique of a sprint by an inclination hold of legs for differently qualified wrestlers in freestyle were ascertained by the biomechanical videocomputer analysis. The results of research of kinematic structure of motor actions technique testify that performance duration of phases in sprint by an inclination hold of legs was characterized by the greater values for qualified wrestlers in comparison with highly skilled ones.

  2. Position and Speed Control of Brushless DC Motors Using Sensorless Techniques and Application Trends

    Directory of Open Access Journals (Sweden)

    Jaime Gómez-Gil

    2010-07-01

    Full Text Available This paper provides a technical review of position and speed sensorless methods for controlling Brushless Direct Current (BLDC motor drives, including the background analysis using sensors, limitations and advances. The performance and reliability of BLDC motor drivers have been improved because the conventional control and sensing techniques have been improved through sensorless technology. Then, in this paper sensorless advances are reviewed and recent developments in this area are introduced with their inherent advantages and drawbacks, including the analysis of practical implementation issues and applications. The study includes a deep overview of state-of-the-art back-EMF sensing methods, which includes Terminal Voltage Sensing, Third Harmonic Voltage Integration, Terminal Current Sensing, Back-EMF Integration and PWM strategies. Also, the most relevant techniques based on estimation and models are briefly analysed, such as Sliding-mode Observer, Extended Kalman Filter, Model Reference Adaptive System, Adaptive observers (Full-order and Pseudoreduced-order and Artificial Neural Networks.

  3. Chondrogenesis of human adipose derived stem cells for future microtia repair using co-culture technique.

    Science.gov (United States)

    Goh, Bee See; Che Omar, Siti Nurhadis; Ubaidah, Muhammad Azhan; Saim, Lokman; Sulaiman, Shamsul; Chua, Kien Hui

    2017-04-01

    In conclusion, these result showed HADSCs could differentiate into chondrocytes-like cells, dependent on signaling induced by TGF-β3 and chondrocytes. This is a promising result and showed that HADSCs is a potential source for future microtia repair. The technique of co-culture is a positive way forward to assist the microtia tissue. Reconstructive surgery for the repair of microtia still remains the greatest challenge among the surgeons. Its repair is associated with donor-site morbidity and the degree of infection is inevitable when using alloplastic prosthesis with uncertain long-term durability. Thus, human adipose derived stem cells (HADSCs) can be an alternative cell source for cartilage regeneration. This study aims to evaluate the chondrogenic potential of HADSCs cultured with transforming growth factor-beta (TGF-β) and interaction of auricular chondrocytes with HADSCs for new cartilage generation. Multi-lineages differentiation features of HADSCs were monitored by Alcian Blue, Alizarin Red, and Oil Red O staining for chondrogenic, adipogenic, and osteogenic differentiation capacity, respectively. Further, HADSCs alone were culture in medium added with TGF-β3; and human auricular chondrocytes were interacted indirectly in the culture with and without TGF-βs for up to 21 days, respectively. Cell morphology and chondrogenesis were monitored by inverted microscope. For cell viability, Alamar Blue assay was used to measure the cell viability and the changes in gene expression of auricular chondrocyte markers were determined by real-time polymerase chain reaction analysis. For the induction of chondrogenic differentiation, HADSCs showed a feature of aggregation and formed a dense matrix of proteoglycans. Staining results from Alizirin Red and Oil Red O indicated the HADSCs also successfully differentiated into adipogenic and osteogenic lineages after 21 days. According to a previous study, HADSCs were strongly positive for the mesenchymal markers CD90, CD73

  4. [MINIMALLY INVASIVE SURGERY FOR DIRECT REPAIR OF LUMBAR SPONDYLOLYSIS BY UTILIZING INTRAOPERATIVE NAVIGATION AND MICROENDOSCOPIC TECHNIQUES].

    Science.gov (United States)

    Zhu, Xiaolong; Wang, Jian; Zhou, Yue; Zhang, Zhengfeng; Li, Changqing; Zheng, Wenjie

    2015-10-01

    To analyze the effectiveness of direct screw repair for lumbar spondylolysis by using intraoperative O-arm based navigation and microendoscopic techniques. Between February 2012 and May 2014, 11 consecutive patients with lumbar spondylolysis were treated with Buck's procedure by the aid of intraoperative O-arm based navigation and minimally invasive approach. The debridement and autograft of pars interarticularis defects was performed under microendoscopy. There were 7 males and 4 females, with an average age of 28.4 years (range, 19 - 47 years) and an average disease duration of 10.5 months (range, 8-23 months); no nerve symptoms or signs of lower limb was observed. The radiological examinations showed single level bilateral lumbar spondylolysis without obvious disc degeneration, lumbar instability, or spondylolisthesis. Isthmic injury located at L4 in 2 cases and at L5 in 9 cases. Of 11 patients, 7 were rated as grade 2 disc degeneration, and 4 as grade 3 disc degeneration according to the modified Pfirrmann classification system. The operation time, intraoperative blood loss, and complications were recorded. The fluoroscopic examinations were performed to assess defect repair and screw position. Visual analogue scale (VAS) score was used to evaluate the improvement of low back pain. The average operation time was 147.6 minutes (range, 126-183 minutes). The average blood loss was 54.9 mL (range, 40-85 mL). Primary healing of incision was obtained. There was no complication of nerve root injury, dural tear, or infection. Three patients had pain at donor site postoperatively, and pain disappeared within 3 weeks. The average follow-up duration was 15.7 months (range, 10-23 months). VAS score of low back pain was significantly decreased from preoperative 7.1 ± 2.3 to 1.8 ± 0.4 at last follow-up (t = 13.42, P = 0.01). Of 22 isthmic bone grafting, bilateral isthmic bony fusion was achieved in 7 patients and unilateral isthmic bony fusion in 3 patients at 6-10 months

  5. One and a half ventricle repair in association with tricuspid valve repair according to "peacock tail" technique in patients with Ebstein's malformation and failing right ventricle.

    Science.gov (United States)

    Prifti, Edvin; Baboci, Arben; Esposito, Giampiero; Kajo, Efrosina; Dado, Elona; Vanini, Vittorio

    2014-05-01

    The aim of this study was to evaluate the outcome in a series of patients with Ebstein's anomaly and a failing right ventricle (RV) undergoing tricuspid valve (TV) repair and bidirectional Glenn cavopulmonary anastomosis (BDG). Between January 2006 and September 2013, 11 consecutive patients diagnosed with severe forms of Ebstein's anomaly and a failing RV underwent TV surgery and BDG. The mean age was 16.5 ± 7 years. Most frequently found symptoms were cyanosis, dyspnea, and arrhythmias. The azygos or hemiazygos veins were left open. The TV was repaired using the "peacock tail" technique, which consisted of total detachment of the anterior and posterior leaflets of the TV and rotation in both directions reimplanting them to the true annulus. The mean follow-up was 3.8 ± 2.4 years (range three months to six years). Hospital mortality was 9% (one patient). TV repair was possible in 10 patients. None of the patients had AV block postoperatively. At one year after surgery, the indexed RV and RA diameter were reduced significantly versus the preoperative data (p = 0.003 and p TV area were 1.2 ± 0.42 and 1.6 ± 0.6 (mm/m2), significantly lower than preoperatively (p = 0.001 and p = 0.008, respectively). The mean NYHA functional class, SaO2 , and cardiothoracic ratio were significantly improved. The peacock tail technique for TV repair in combination with BDG in patients with Ebstein's malformation and depressed RV function results in TV preservation, a low incidence of recurrent regurgitation, favorable functional status and RV function, and resolution of cyanosis. © 2014 Wiley Periodicals, Inc.

  6. Arthroscopic anterior talofibular ligament repair for chronic ankle instability with a suture anchor technique.

    Science.gov (United States)

    Kim, Eung Soo; Lee, Kyung Tai; Park, Jun Sic; Lee, Young Koo

    2011-04-11

    The goal of this study was to retrospectively evaluate the clinical outcomes of arthroscopic repair for chronic ankle instability using a bioabsorbable anchor with 2 sutures. We evaluated the results of 28 ankles treated with arthroscopic anterior talofibular ligament repair using bioabsorbable anchors with a FiberWire and TigerWire suture (Arthrex, Inc, Naples, Florida) placed on the fibula from March 2008 to January 2009. Average follow-up was 15.9 months (range, 13-25 months). Patients were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot ankle score and stress radiographs. Mean AOFAS hindfoot ankle score was 92.48 ± 6.14 at last follow-up compared to the mean preoperative score of 60.78 ± 16.38 (P=.041). Mean postoperative anterior draw test score difference between 2 ankles was 0.61 ± 0.75 compared to the mean preoperative score difference of 3.59 ± 0.68 (P=.00). There was a 14% complication rate, including 3 cases of portal site irritation and 1 case of superficial infection. Stress radiographs revealed 3 cases of anterior displacement >3 mm compared to the other side. All patients returned to their previous activity level.Arthroscopic ligament reconstruction for chronic lateral ankle instability using suture anchors is effective in returning patients to their preinjury function levels. Good clinical results were obtained with some minor complications. This minimally invasive technique is a reasonable alternative to other open surgical procedures for chronic ankle instability. Copyright 2011, SLACK Incorporated.

  7. Comprehensive Biological Monitoring to Assess Isocyanates and Solvents Exposure in the NSW Australia Motor Vehicle Repair Industry.

    Science.gov (United States)

    Hu, Jimmy; Cantrell, Phillip; Nand, Aklesh

    2017-10-01

    Urethane products that contain isocyanates are extensively used in the motor vehicle repair (MVR) industry and other industries such as furniture and cabinet-making as two-pack spray paints, clears, and adhesives. Attention has recently been refocussed on isocyanate-containing chemicals, particularly in paints. The spray painters in the MVR industry had a propensity to develop industrial asthma at a rate 80 times higher than the general public, which was previously reported in the UK. To track workers exposure to isocyanates, urine samples were collected from 196 spray painters who worked mainly in 78 MVR shops across 54 New South Wales (NSW) towns and suburbs. The biological monitoring also covered exposure testing to a wide variety of solvents including aromatic hydrocarbons, ketones, and alcohols. The main finding of the study was that 2.6% of the spray painters surveyed in the MVR industry in NSW that handled isocyanate-containing paints showed exposure to isocyanates; with 1.0% being moderately exposed, which is more than twice the current UK's Health and Safety Executive (HSE) Biological Monitoring Guidance Value (BMGV) of 1 µmol mol-1 creatinine. Potential exposures to toluene (a solvent often found in paint thinners) was monitored via hippuric acid (HA) urine levels and showed 2.6% of the spray painters surveyed to be over the US' American Conference of Government Industrial Hygienists (ACGIH) Biological Exposure Index (BEI) of 1010 mmol/mole creatinine for HA. The other solvents or their metabolites were all below their respective BEI; these comprised benzene, xylene, ethyl benzene, methyl ethyl ketone, acetone, methanol, and ethanol. These findings indicate that isocyanates and certain solvents exposure were occurring in the NSW Australia vehicle repair industry, albeit at lower levels than previous occupational biological monitoring studies that showed higher exposure levels, particularly for isocyanates. One reason for this could be the increasing use

  8. The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

    International Nuclear Information System (INIS)

    Jaffan, Abdel Aziz A.; Prince, Ethan A.; Hampson, Christopher O.; Murphy, Timothy P.

    2013-01-01

    Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size (≥20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

  9. Review of In-Service Inspection and Repair Technique Developments for French Liquid Metal Fast Reactors

    International Nuclear Information System (INIS)

    Baque, F.

    2005-01-01

    In-service monitoring of nuclear plants is indispensable for both the Operator and the Regulator. The notion of in-service monitoring ranges from the continuous monitoring of the reactor in operation to the thorough in-service reactor inspection during programmed shutdowns. However, the highly specific environment found in French liquid metal fast reactor plants - Phenix and Superphenix - makes monitoring and inspection complicated because of the use of a sodium coolant that is hot, opaque, and difficult to drain.The Commissariat a l'Energie Atomique, in collaboration with its traditional French partners, Electricite de France utilities and FRAMATOME/Novatome Engineering, decided to conduct a 6-yr research and development program (1994-2000) to explore this problem vis-a-vis Superphenix, as well as the possibilities of intervening within the reactor block or on components in a sodium environment. Furthermore, the safety reevaluation of Phenix, conducted between 1994 and 2003, represented an excellent 'test bench' during which the limits of inspection processes - applied to an integrated reactor concept - were surpassed using techniques such as fuel subassembly head scanning, ultrasonic examination of the core support, and visual inspection of the cover-gas plenum following a partial sodium draining. Repair techniques were investigated for cleaning of sodium wet structure surfaces, cutting of damaged parts, and welding in sodium aerosol atmosphere. Both conventional and laser processes were tested

  10. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique.

    Science.gov (United States)

    Mihata, Teruhisa; Fukuhara, Tetsutaro; Jun, Bong Jae; Watanabe, Chisato; Kinoshita, Mitsuo

    2011-03-01

    After rotator cuff repair, the shoulder is immobilized in various abduction positions. However, there is no consensus on the proper abduction angle. To assess the effect of shoulder abduction angle on the biomechanical properties of the repaired rotator cuff tendons among 3 types of double-row techniques. Controlled laboratory study. Thirty-two fresh-frozen porcine shoulders were used. A simulated rotator cuff tear was repaired by 1 of 3 double-row techniques: conventional double-row repair, transosseous-equivalent repair, and a combination of conventional double-row and bridging sutures (compression double-row repair). Each specimen underwent cyclic testing followed by tensile testing to failure at a simulated shoulder abduction angle of 0° or 40° on a material testing machine. Gap formation and failure loads were measured. Gap formation in conventional double-row repair at 0° (1.2 ± 0.5 mm) was significantly greater than that at 40° (0.5 ± 0.3mm, P = .01). The yield and ultimate failure loads for conventional double-row repair at 40° were significantly larger than those at 0° (P row repair (P row repair was the greatest among the 3 double-row techniques at both 0° and 40° of abduction. Bridging sutures have a greater effect on the biomechanical properties of the repaired rotator cuff tendon at a low abduction angle, and the conventional double-row technique has a greater effect at a high abduction angle. Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.

  11. Current Biomechanical Concepts of Suture Bridge Repair Technique for Rotator Cuff Tear

    OpenAIRE

    Ming-Long Yeh; Chih-Kai Hong; Wei-Ren Su; I-Ming Jou; Cheng-Li Lin; Chii-Jen Lin

    2015-01-01

    Rotator cuff tears are one of the most common disorders of the shoulder and can have significant effects on daily activities as a result of pain, loss of motion and strength. The goal of rotator cuff repair is aimed at anatomic restoration of the rotator cuff tendon to reduce pain and improve the joint function. Recently, arthroscopic repair has been widely accepted for treatment of rotator cuff tears due to its equal or better results than those from open repair. In 2006, a...

  12. The use of recombinant DNA techniques to study radiation-induced damage, repair and genetic change in mammalian cells

    International Nuclear Information System (INIS)

    Thacker, J.

    1986-01-01

    A brief introduction is given to appropriate elements of recombinant DNA techniques and applications to problems in radiobiology are reviewed with illustrative detail. Examples are included of studies with both 254 nm ultraviolet light and ionizing radiation and the review progresses from the molecular analysis of DNA damage in vitro through to the nature of consequent cellular responses. The review is dealt with under the following headings: Molecular distribution of DNA damage, The use of DNA-mediated gene transfer to assess damage and repair, The DNA double strand break: use of restriction endonucleases to model radiation damage, Identification and cloning of DNA repair genes, Analysis of radiation-induced genetic change. (UK)

  13. Fetoscopic Open Neural Tube Defect Repair: Development and Refinement of a Two-Port, Carbon Dioxide Insufflation Technique.

    Science.gov (United States)

    Belfort, Michael A; Whitehead, William E; Shamshirsaz, Alireza A; Bateni, Zhoobin H; Olutoye, Oluyinka O; Olutoye, Olutoyin A; Mann, David G; Espinoza, Jimmy; Williams, Erin; Lee, Timothy C; Keswani, Sundeep G; Ayres, Nancy; Cassady, Christopher I; Mehollin-Ray, Amy R; Sanz Cortes, Magdalena; Carreras, Elena; Peiro, Jose L; Ruano, Rodrigo; Cass, Darrell L

    2017-04-01

    To describe development of a two-port fetoscopic technique for spina bifida repair in the exteriorized, carbon dioxide-filled uterus and report early results of two cohorts of patients: the first 15 treated with an iterative technique and the latter 13 with a standardized technique. This was a retrospective cohort study (2014-2016). All patients met Management of Myelomeningocele Study selection criteria. The intraoperative approach was iterative in the first 15 patients and was then standardized. Obstetric, maternal, fetal, and early neonatal outcomes were compared. Standard parametric and nonparametric tests were used as appropriate. Data for 28 patients (22 endoscopic only, four hybrid, two abandoned) are reported, but only those with a complete fetoscopic repair were analyzed (iterative technique [n=10] compared with standardized technique [n=12]). Maternal demographics and gestational age (median [range]) at fetal surgery (25.4 [22.9-25.9] compared with 24.8 [24-25.6] weeks) were similar, but delivery occurred at 35.9 (26-39) weeks of gestation with the iterative technique compared with 39 (35.9-40) weeks of gestation with the standardized technique (Pmet in 9 of 12 (75%) and 3 of 10 (30%), respectively, and 7 of 12 (58%) compared with 2 of 10 (20%) have been treated for hydrocephalus to date. These latter differences were not statistically significant. Fetoscopic open neural tube defect repair does not appear to increase maternal-fetal complications as compared with repair by hysterotomy, allows for vaginal delivery, and may reduce long-term maternal risks. ClinicalTrials.gov, https://clinicaltrials.gov, NCT02230072.

  14. Indications, techniques, and outcomes of arthroscopic repair of scapholunate ligament and triangular fibrocartilage complex.

    Science.gov (United States)

    Mathoulin, C L

    2017-07-01

    This review includes updated understanding of the roles of intrinsic and extrinsic carpal ligaments in scapholunate instability and details the author's experience of indications, arthroscopic repair methods, and outcomes of treating the instability. A classification on triangular fibrocartilage complex injuries is reviewed, followed by author's indications, methods, and outcomes of arthroscopic repair of triangular fibrocartilage complex injuries.

  15. Anatomic suture anchor versus the Broström technique for anterior talofibular ligament repair: a biomechanical comparison.

    Science.gov (United States)

    Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O

    2012-11-01

    Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than

  16. Dynamic augmentation restores anterior tibial translation in ACL suture repair: a biomechanical comparison of non-, static and dynamic augmentation techniques.

    Science.gov (United States)

    Hoogeslag, Roy A G; Brouwer, Reinoud W; Huis In 't Veld, Rianne; Stephen, Joanna M; Amis, Andrew A

    2018-02-03

    There is a lack of objective evidence investigating how previous non-augmented ACL suture repair techniques and contemporary augmentation techniques in ACL suture repair restrain anterior tibial translation (ATT) across the arc of flexion, and after cyclic loading of the knee. The purpose of this work was to test the null hypotheses that there would be no statistically significant difference in ATT after non-, static- and dynamic-augmented ACL suture repair, and they will not restore ATT to normal values across the arc of flexion of the knee after cyclic loading. Eleven human cadaveric knees were mounted in a test rig, and knee kinematics from 0° to 90° of flexion were recorded by use of an optical tracking system. Measurements were recorded without load and with 89-N tibial anterior force. The knees were tested in the following states: ACL-intact, ACL-deficient, non-augmented suture repair, static tape augmentation and dynamic augmentation after 10 and 300 loading cycles. Only static tape augmentation and dynamic augmentation restored ATT to values similar to the ACL-intact state directly postoperation, and maintained this after cyclic loading. However, contrary to dynamic augmentation, the ATT after static tape augmentation failed to remain statistically less than for the ACL-deficient state after cyclic loading. Moreover, after cyclic loading, ATT was significantly less with dynamic augmentation when compared to static tape augmentation. In contrast to non-augmented ACL suture repair and static tape augmentation, only dynamic augmentation resulted in restoration of ATT values similar to the ACL-intact knee and decreased ATT values when compared to the ACL-deficient knee immediately post-operation and also after cyclic loading, across the arc of flexion, thus allowing the null hypotheses to be rejected. This may assist healing of the ruptured ACL. Therefore, this study would support further clinical evaluation of dynamic augmentation of ACL repair.

  17. Comparison of histologic healing and biomechanical characteristics between repair techniques for a delaminated rotator cuff tear in rabbits.

    Science.gov (United States)

    Cheon, Sang-Jin; Kim, Jung-Han; Gwak, Heui-Chul; Kim, Chang-Wan; Kim, Jeon-Kyo; Park, Ji-Hwan

    2017-05-01

    The purpose of this study was to compare histologic healing and biomechanical characteristics between 2 repair techniques (layer by layer, repair of each layer to bone separately; and whole layer, repair of each layer to the bone en masse) for delaminated rotator cuff tear. Rabbits were used as subjects and classified into 2 groups: group A, right side, the layer-by-layer repair group; and group B, left side, the whole-layer repair group. Histologic evaluations were done at 3 weeks (n = 7) and 6 weeks (n = 4) after operation. Biomechanical tests to evaluate the tensile property were done at time 0 (n = 5) and 3 weeks (n = 5) after operation. Histologic healing improved in all groups. A smaller cleft was found between layers in group B compared with the cleft in group A at 3 weeks after operation. At time 0, group A showed a higher yield load and ultimate failure load (67 ± 10.5 N and 80 ± 7.8 N, respectively). However, at 3 weeks after operation, group B showed a higher yield load (48 ± 7.6 N). In the delaminated rotator cuff tear model in the rabbit, the whole-layer repair showed a narrow gap between layers and a higher yield load at 3 weeks after operation. Surgical techniques that unite the cleft in a delaminated tear could improve biomechanical strength after operation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Four-Strand Core Suture Improves Flexor Tendon Repair Compared to Two-Strand Technique in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Alice Wichelhaus

    2016-01-01

    Full Text Available Introduction. This study was designed to investigate the influence of the amount of suture material on the formation of peritendinous adhesions of intrasynovial flexor tendon repairs. Materials and Methods. In 14 rabbits, the flexor tendons of the third and the fourth digit of the right hind leg were cut and repaired using a 2- or 4-strand core suture technique. The repaired tendons were harvested after three and eight weeks. The range of motion of the affected toes was measured and the tendons were processed histologically. The distance between the transected tendon ends, the changes in the peritendinous space, and cellular and extracellular inflammatory reaction were quantified by different staining. Results. A 4-strand core suture resulted in significantly less gap formation. The 2-strand core suture showed a tendency to less adhesion formation. Doubling of the intratendinous suture material was accompanied by an initial increase in leukocyte infiltration and showed a greater amount of formation of myofibroblasts. From the third to the eighth week after flexor tendon repair, both the cellular and the extracellular inflammation decreased significantly. Conclusion. A 4-strand core suture repair leads to a significantly better tendon healing process with less diastasis between the sutured tendon ends despite initially pronounced inflammatory response.

  19. Postpartum perineal reapir performed by midwives: A randomised trial comparing two suture techniques for perineal repair leaving the skin unsutured

    DEFF Research Database (Denmark)

    Kindberg, Sara; Misan, Stehouwer; Hvidman, Lone

    2008-01-01

    Postpartum perineal repair performed by midwives: A randomised trial comparing two suture techniques leaving the skin unsutured. Objective      To compare a continuous suture technique to interrupted stitches using inverted knots for postpartum perineal repair of second-degree lacerations...... and episiotomies.   Design          A double blind randomised controlled trial.   Setting          A Danish university hospital with more than 4800 deliveries annually.   Population   400 healthy primiparous women with a vaginal delivery at term.   Method         Randomisation was computer-controlled. Structured...... healing, patient satisfaction, dyspareunia or need for resuturing. The continuous suture technique was significantly faster (15 min. vs. 17 min, p=0.03) and less suture material was used (1 vs. 2 packets, pskin unsutured...

  20. Evaluation of different techniques for repair of co-arctation of aorta

    Directory of Open Access Journals (Sweden)

    Karimi AA

    1998-08-01

    Full Text Available This study is on different surgical techniques for repair of Co-arctation of aort and their effect for correction of systemic hypertension and lower extremity hypotension. In addition to these, the clinical and paraclinical data were noticed. 50 pt were operated in "SHARIATI" hospital during 1370-1377 with diagnosis of Co-arctation of aorta (30 men, mean age 19.4 years, 20 women, mean age 16.6 years. In addition to older age of our patients which results in more post-op sequela, there was suprrisingly a long-lag between onset of symptoms, diagnosis and operation (mean 4.36 years. 62% of Co-arctation were juxtaductal and the remainder were non-classical forms. 52% of our patients had co-existing cardiac disease which were very high in comparison with other studies (12%. This is due to older age of our patients and more valvular heart diseases. Among complicated cases of co-arctation, 71.9% were in men and 28.1% in women and this difference is due to high incidence of bicuspid aortic valve in men. The mean angiographic gradient were 57.5 mmHg which increases with age. CXR was abnormal in 91.7% and ECG in 74.2% of patients. The different applied surgical techniques include ee-A=26%, TIG=40%, TBG=18%, DPR=14%, FSCR=2%. There is no significant difference regarding post-op complications, BP in post-op period, and increase in pedal pulses, except in TBG group which HTN was more common. Two early deaths occurred which were in DRP group.

  1. Modified closed-loop double-endobutton technique for repair of rockwood type III acromioclavicular dislocation

    Science.gov (United States)

    Zhang, Lei; Zhou, Xin; Qi, Ji; Zeng, Yan; Zhang, Shaoqun; Liu, Gang; Ping, Ruiyue; Li, Yikai; Fu, Shijie

    2018-01-01

    Acromioclavicular dislocation (ACD) is a common injury. According to the Rockwood classification, ACD is classified into six types (type I–VI); however, for type III injuries, it remains controversial whether or not operative treatment should be applied. Numerous studies have advocated early surgical treatment to ensure early rehabilitation activities. Thus, the present study aimed to investigate a modified closed-loop double-endobutton technique (MCDT), that may be used to repair Rockwood type III ACD. In the current study, 61 patients with Rockwood type III ACD were enrolled during a period of 5 years at the Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University. Patients were divided into three groups according to the surgical method used, the MCDT group (n=20), the common closed-loop double-endobutton technique (CCDT) group (n=21), and the clavicular hook plate fixation (CHPF) group (n=20). Preoperative and intraoperative information were recorded. Furthermore, the functional scores of injured shoulder were evaluated prior to surgery and following surgery with a 1-year follow-up. Among the three groups, postoperative functional scores were significantly more improved compared with those prior to surgery (P0.05). Postoperative functional scores in the MCDT and CCDT groups were significantly more improved compared those in the CHPF group (P<0.05). In addition, the duration of surgery in the MCDT group was significantly shorter compared with that in the CCDT group (P<0.05). Furthermore, compared with the CHPF group, the incision length was significantly shorter with reduced hemorrhage in the MCDT group (P<0.05). In conclusion, the results of the current study suggest that MCDT is more simple, convenient and efficient compared with CCDT, and is worth popularizing. PMID:29399102

  2. Arthroscopic Bankart repair and subscapularis augmentation: an alternative technique treating anterior shoulder instability with bone loss.

    Science.gov (United States)

    Maiotti, Marco; Russo, Raffaele; Zanini, Antonio; Schröter, Steffen; Massoni, Carlo; Bianchedi, Diana

    2016-06-01

    This study presents the preliminary results of a new arthroscopic technique consisting of the association of 2 procedures, capsulolabral repair and subscapularis augmentation tenodesis, in the treatment of traumatic anterior shoulder instability with both glenoid bone loss and a Hill-Sachs lesion. Eighty-nine patients engaged in sports were enrolled in this retrospective case-series study with 2 to 5 years' follow-up. All patients underwent a computed tomography scan to assess the percentage of glenoid bone loss by the Pico method. A prior stabilization procedure had failed in 20 patients, who were then segregated into a different group. Visual analog scale (VAS), Rowe, and American Shoulder and Elbow Surgeons (ASES) scores were used to assess the results. Only 3 of 89 patients had a post-traumatic redislocation. The mean length of follow-up was 31.5 months (range, 25-60 months). The VAS, Rowe, and ASES scores showed significant improvements: The VAS score decreased from a mean of 3.1 to 0.5 (P = .0157), the Rowe score increased from 58.9 to 94.1 (P = .0215), and the ASES score increased from 68.5 to 95.5 (P = .0197). The mean deficit of external rotation was 6° with the arm at the side of the trunk, and the mean deficit was 3° with the arm in 90° of abduction. The described procedure is a reproducible and effective technique used to restore joint stability in patients engaged in sports who have incurred anterior recurrent shoulder dislocation associated with glenoid bone loss (Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration

    Science.gov (United States)

    Makris, Eleftherios A.; Hadidi, Pasha; Athanasiou, Kyriacos A.

    2011-01-01

    Extensive scientific investigations in recent decades have established the anatomical, biomechanical, and functional importance that the meniscus holds within the knee joint. As a vital part of the joint, it acts to prevent the deterioration and degeneration of articular cartilage, and the onset and development of osteoarthritis. For this reason, research into meniscus repair has been the recipient of particular interest from the orthopedic and bioengineering communities. Current repair techniques are only effective in treating lesions located in the peripheral vascularized region of the meniscus. Healing lesions found in the inner avascular region, which functions under a highly demanding mechanical environment, is considered to be a significant challenge. An adequate treatment approach has yet to be established, though many attempts have been undertaken. The current primary method for treatment is partial meniscectomy, which commonly results in the progressive development of osteoarthritis. This drawback has shifted research interest towards the fields of biomaterials and bioengineering, where it is hoped that meniscal deterioration can be tackled with the help of tissue engineering. So far, different approaches and strategies have contributed to the in vitro generation of meniscus constructs, which are capable of restoring meniscal lesions to some extent, both functionally as well as anatomically. The selection of the appropriate cell source (autologous, allogeneic, or xenogeneic cells, or stem cells) is undoubtedly regarded as key to successful meniscal tissue engineering. Furthermore, a large variation of scaffolds for tissue engineering have been proposed and produced in experimental and clinical studies, although a few problems with these (e.g., byproducts of degradation, stress shielding) have shifted research interest towards new strategies (e.g., scaffoldless approaches, self-assembly). A large number of different chemical (e.g., TGF-β1, C-ABC) and

  4. An Intelligent Harmonic Synthesis Technique for Air-Gap Eccentricity Fault Diagnosis in Induction Motors

    Science.gov (United States)

    Li, De Z.; Wang, Wilson; Ismail, Fathy

    2017-11-01

    Induction motors (IMs) are commonly used in various industrial applications. To improve energy consumption efficiency, a reliable IM health condition monitoring system is very useful to detect IM fault at its earliest stage to prevent operation degradation, and malfunction of IMs. An intelligent harmonic synthesis technique is proposed in this work to conduct incipient air-gap eccentricity fault detection in IMs. The fault harmonic series are synthesized to enhance fault features. Fault related local spectra are processed to derive fault indicators for IM air-gap eccentricity diagnosis. The effectiveness of the proposed harmonic synthesis technique is examined experimentally by IMs with static air-gap eccentricity and dynamic air-gap eccentricity states under different load conditions. Test results show that the developed harmonic synthesis technique can extract fault features effectively for initial IM air-gap eccentricity fault detection.

  5. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  6. Assessment of Concrete Repair Techniques for Radiologically-Contaminated Tank Farm Pump and Valve Pits

    International Nuclear Information System (INIS)

    MINTEER, D.J.

    2000-01-01

    As part of the scope of Project W-314, ''Tank Farm Restoration and Safe Operations,'' the condition of pump and valve pit walls and floors is being assessed, and repairs made as needed, to support upgrading the infrastructure necessary to safely transfer tank waste for treatment. Flaws in the surfaces of the pits (e.g., concrete crack/faults, protective coating deterioration) must be repaired to ensure containment integrity and to facilitate future decontamination of the pits. This engineering study presents a cost/risk/benefit evaluation of concrete and protective coating repair methods in pump and valve pits using various manual and remote tool systems

  7. Rotor Pole Shape Optimization of Permanent Magnet Brushless DC Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    GHOLAMIAN, A. S.

    2009-06-01

    Full Text Available In this paper, a magnet shape optimization method for reduction of cogging torque and torque ripple in Permanent Magnet (PM brushless DC motors is presented by using the reduced basis technique coupled by finite element and design of experiments methods. The primary objective of the method is to reduce the enormous number of design variables required to define the magnet shape. The reduced basis technique is a weighted combination of several basis shapes. The aim of the method is to find the best combination using the weights for each shape as the design variables. A multi-level design process is developed to find suitable basis shapes or trial shapes at each level that can be used in the reduced basis technique. Each level is treated as a separated optimization problem until the required objective is achieved. The experimental design of Taguchi method is used to build the approximation model and to perform optimization. This method is demonstrated on the magnet shape optimization of a 6-poles/18-slots PM BLDC motor.

  8. Speed control of induction motor using fuzzy recursive least squares technique

    OpenAIRE

    Santiago Sánchez; Eduardo Giraldo

    2008-01-01

    A simple adaptive controller design is presented in this paper, the control system uses the adaptive fuzzy logic, sliding modes and is trained with the recursive least squares technique. The problem of parameter variation is solved with the adaptive controller; the use of an internal PI regulator produces that the speed control of the induction motor be achieved by the stator currents instead the input voltage. The rotor-flux oriented coordinated system model is used to develop and test the c...

  9. Speed control of induction motor using fuzzy recursive least squares technique

    Directory of Open Access Journals (Sweden)

    Santiago Sánchez

    2008-12-01

    Full Text Available A simple adaptive controller design is presented in this paper, the control system uses the adaptive fuzzy logic, sliding modes and is trained with the recursive least squares technique. The problem of parameter variation is solved with the adaptive controller; the use of an internal PI regulator produces that the speed control of the induction motor be achieved by the stator currents instead the input voltage. The rotor-flux oriented coordinated system model is used to develop and test the control system.

  10. Is the Dresden technique a mechanical design of choice suitable for the repair of middle third Achilles tendon ruptures? A biomechanical study.

    Science.gov (United States)

    de la Fuente, C; Carreño-Zillmann, G; Marambio, H; Henríquez, H

    2016-01-01

    To compare the mechanical failure of the Dresden technique for Achilles tendon repair with the double modified Kessler technique controlled repair technique. The maximum resistance of the two repair techniques are also compared. A total of 30 Achilles tendon ruptures in bovine specimens were repaired with an Ethibond(®) suture to 4.5cm from the calcaneal insertion. Each rupture was randomly distributed into one of two surgical groups. After repair, each specimen was subjected to a maximum traction test. The mechanical failure (tendon, suture, or knot) rates (proportions) were compared using the exact Fisher test (α=.05), and the maximum resistances using the Student t test (α=.05). There was a difference in the proportions of mechanical failures, with the most frequent being a tendon tear in the Dresden technique, and a rupture of the suture in the Kessler technique. The repair using the Dresden technique performed in the open mode, compared to the Kessler technique, has a more suitable mechanical design for the repair of middle third Achilles tendon ruptures on developing a higher tensile resistance in 58.7%. However, its most common mechanical failure was a tendon tear, which due to inappropriate loads could lead to lengthening of the Achilles tendon. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Lingual mucosal graft two-stage Bracka technique for redo hypospadias repair

    Directory of Open Access Journals (Sweden)

    Ahmed Sakr

    2017-09-01

    Conclusion: Lingual mucosa is a reliable and versatile graft material in the armamentarium of two-stage Bracka hypospadias repair with the merits of easy harvesting and minor donor-site complications.

  12. Modified suture-bridge technique to prevent a marginal dog-ear deformity improves structural integrity after rotator cuff repair.

    Science.gov (United States)

    Ryu, Keun Jung; Kim, Bang Hyun; Lee, Yohan; Lee, Yoon Seok; Kim, Jae Hwa

    2015-03-01

    The arthroscopic suture-bridge technique has proved to provide biomechanically firm fixation of the torn rotator cuff to the tuberosity by increasing the footprint contact area and pressure. However, a marginal dog-ear deformity is encountered not infrequently when this technique is used, impeding full restoration of the torn cuff. To evaluate the structural and functional outcomes of the use of a modified suture-bridge technique to prevent a marginal dog-ear deformity compared with a conventional suture-bridge method in rotator cuff repair. Cohort study; Level of evidence 2. A consecutive series of 71 patients aged 50 to 65 years who underwent arthroscopic rotator cuff repair for full-thickness medium-sized to massive tears was evaluated. Patients were divided into 2 groups according to repair technique: a conventional suture-bridge technique (34 patients; group A) versus a modified suture-bridge technique to prevent a marginal dog-ear deformity (37 patients; group B). Radiographic evaluations included postoperative cuff integrity using MRI. Functional evaluations included pre- and postoperative range of motion (ROM), pain visual analog scale (VAS), the University of California, Los Angeles (UCLA) shoulder rating scale, the Constant score, and the American Shoulder and Elbow Surgeons (ASES) score. All patients were followed up clinically at a minimum of 1 year. When the 2 surgical techniques were compared, postoperative structural integrity by Sugaya classification showed the distribution of types I:II:III:IV:V to be 4:20:2:4:4 in group A and 20:12:4:0:1 in group B. More subjects in group B had a favorable Sugaya type compared with group A (P bridge technique repairs were found in the retear group (P = .03). There were significant differences between healed and retear groups in functional outcome scores, with worse results in the retear group. A modified suture-bridge technique to prevent a marginal dog-ear deformity provided better structural outcomes than a

  13. A Comparison of the Need for Speech Therapy After 2 Palatal Repair Techniques.

    Science.gov (United States)

    Yen, Debra W; Nguyen, Dennis C; Skolnick, Gary B; Naidoo, Sybill D; Patel, Kamlesh B; Grames, Lynn Marty; Woo, Albert S

    2017-03-01

    Reconstruction of the levator musculature during cleft palate repair has been suggested to be important in long-term speech outcomes. In this study, we compare the need for postoperative speech therapy between 2 intravelar veloplasty techniques. Chart review was performed for patients with nonsyndromic cleft palate who underwent either primary Kriens or overlapping intravelar veloplasty before 18 months of age. All subjects completed a follow-up visit at approximately 3 years of age. Data obtained included documentation of ongoing or recommended speech therapy at age 3 years and reasons for speech therapy, which were categorized as cleft-related and non-cleft-related by a speech-language pathologist. One surgeon performed all Kriens procedures (n = 81), and the senior author performed all overlapping procedures (n = 25). Mean age at surgery (Kriens = 13.5 ± 1.4 months; overlapping = 13.1 ± 1.5 months; P = 0.188) and age at 3-year follow-up (Kriens = 3.0 ± 0.5 years; overlapping = 2.8 ± 0.5 years; P = 0.148) were equivalent in both groups. Cleft severity by Veau classification (P = 0.626), prepalatoplasty pure tone averages, (P = 0.237), pure tone averages at 3-year follow-up (P = 0.636), and incidence of prematurity (P = 0.190) were also similar between the 2 groups. At 3 years of age, significantly fewer overlapping intravelar veloplasty patients required cleft-related speech therapy (Kriens = 47%; overlapping = 20%; P = 0.015). The proportions of patients requiring non-cleft-related speech therapy were equivalent (P = 0.906). At 3 years of age, patients who received overlapping intravelar veloplasty were significantly less likely to need cleft-related speech therapy compared with patients who received Kriens intravelar veloplasty. Cleft severity, hearing loss, and prematurity at birth did not appear to explain the difference found in need for speech therapy.

  14. A Simulation Based Analysis of Motor Unit Number Index (MUNIX) Technique Using Motoneuron Pool and Surface Electromyogram Models

    Science.gov (United States)

    Li, Xiaoyan; Rymer, William Zev; Zhou, Ping

    2013-01-01

    Motor unit number index (MUNIX) measurement has recently achieved increasing attention as a tool to evaluate the progression of motoneuron diseases. In our current study, the sensitivity of the MUNIX technique to changes in motoneuron and muscle properties was explored by a simulation approach utilizing variations on published motoneuron pool and surface electromyogram (EMG) models. Our simulation results indicate that, when keeping motoneuron pool and muscle parameters unchanged and varying the input motor unit numbers to the model, then MUNIX estimates can appropriately characterize changes in motor unit numbers. Such MUNIX estimates are not sensitive to different motor unit recruitment and rate coding strategies used in the model. Furthermore, alterations in motor unit control properties do not have a significant effect on the MUNIX estimates. Neither adjustment of the motor unit recruitment range nor reduction of the motor unit firing rates jeopardizes the MUNIX estimates. The MUNIX estimates closely correlate with the maximum M wave amplitude. However, if we reduce the amplitude of each motor unit action potential rather than simply reduce motor unit number, then MUNIX estimates substantially underestimate the motor unit numbers in the muscle. These findings suggest that the current MUNIX definition is most suitable for motoneuron diseases that demonstrate secondary evidence of muscle fiber reinnervation. In this regard, when MUNIX is applied, it is of much importance to examine a parallel measurement of motor unit size index (MUSIX), defined as the ratio of the maximum M wave amplitude to the MUNIX. However, there are potential limitations in the application of the MUNIX methods in atrophied muscle, where it is unclear whether the atrophy is accompanied by loss of motor units or loss of muscle fiber size. PMID:22514208

  15. An integrated approach to the biomechanics and motor control of cricket fast bowling techniques.

    Science.gov (United States)

    Glazier, Paul S; Wheat, Jonathan S

    2014-01-01

    To date, scientific investigations into the biomechanical aspects of cricket fast bowling techniques have predominantly focused on identifying the mechanical factors that may predispose fast bowlers to lower back injury with a relative paucity of research being conducted on the technical features that underpin proficient fast bowling performance. In this review paper, we critique the scientific literature examining fast bowling performance. We argue that, although many published investigations have provided some useful insights into the biomechanical factors that contribute to a high ball release speed and, to a lesser extent, bowling accuracy, this research has not made a substantive contribution to knowledge enhancement and has only had a very minor influence on coaching practice. To significantly enhance understanding of cricket fast bowling techniques and, therefore, have greater impact on practice, we recommend that future scientific research adopts an interdisciplinary focus, integrating biomechanical measurements with the analytical tools and concepts of dynamical systems motor control theory. The use of qualitative (topological) analysis techniques, in particular, promises to increase understanding of the coordinative movement patterns that define 'technique' in cricket fast bowling and potentially help distinguish between functional and dysfunctional aspects of technique for individual fast bowlers.

  16. A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior.

    Science.gov (United States)

    Spang, Jeffrey T; Buchmann, Stefan; Brucker, Peter U; Kouloumentas, Panos; Obst, Tobias; Schröder, Manuel; Burgkart, Rainer; Imhoff, Andreas B

    2009-08-01

    A novel double-row configuration was compared with a traditional double-row configuration for rotator cuff repair. In 10 matched-pair sheep shoulders in vitro repair was performed with either a double-row technique with corkscrew suture anchors for the medial row and insertion anchors for the lateral row (group A) or a double-row technique with a new tape-like suture material with insertion anchors for both the medial and lateral rows (group B). Each specimen underwent cyclic loading from 10 to 150 N for 100 cycles, followed by unidirectional failure testing. Gap formation and strain within the repair area for the first and last cycles were analyzed with a video digitizing system, and stiffness and failure load were determined from the load-elongation curve. The results were similar for the 2 repair types. There was no significant difference between the ultimate failure loads of the 2 techniques (421 +/- 150 N in group A and 408 +/- 66 N in group B, P = .31) or the stiffness of the 2 techniques (84 +/- 26 N/mm in group A and 99 +/- 20 N/mm in group B, P = .07). In addition, gap formation was not different between the repair types. Strain over the repair area was also not different between the repair types. Both tested rotator cuff repair techniques had high failure loads, limited gap formation, and acceptable strain patterns. No significant difference was found between the novel and conventional double-row repair types. Two double-row techniques-one with corkscrew suture anchors for the medial row and insertion anchors for the lateral row and one with insertion anchors for both the medial and lateral rows-provided excellent biomechanical profiles at time 0 for double-row repairs in a sheep model. Although the sheep model may not directly correspond to in vivo conditions, all-insertion anchor double-row constructs are worthy of further investigation.

  17. Comparison of Passive Stiffness Changes in the Supraspinatus Muscle after Double-row and Knotless Transosseous-equivalent Rotator Cuff Repair Techniques: A Cadaveric Study

    Science.gov (United States)

    Hatta, Taku; Giambini, Hugo; Hooke, Alexander W.; Zhao, Chunfeng; Sperling, John W.; Steinmann, Scott P.; Yamamoto, Nobuyuki; Itoi, Eiji; An, Kai-Nan

    2016-01-01

    Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double-row (DR) and knotless transosseous-equivalent (KL-TOE) repair techniques, using the shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh-frozen cadaveric shoulders with rotator cuff tear (tear size; small [6], medium-large [6]) were used. Passive stiffness of four anatomical regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL-TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increase ratio of SWE values after repair was compared among the four regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium-large size tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL-TOE repair showed uniform stiffness changes among the four regions of the supraspinatus muscle (mean, 189-218% increase after repair), whereas, DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187-319% after repair, P = 0.002). Although a repair-induced increase in muscle stiffness was observed also in small size tear, there were no significant differences in repaired stiffness changes between DR and KL-TOE (mean, 127-138% and 127-130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the four regions of the supraspinatus muscle (mean, 38.2-43.0 kPa). Conclusion Passive

  18. Stable adaptive PI control for permanent magnet synchronous motor drive based on improved JITL technique.

    Science.gov (United States)

    Zheng, Shiqi; Tang, Xiaoqi; Song, Bao; Lu, Shaowu; Ye, Bosheng

    2013-07-01

    In this paper, a stable adaptive PI control strategy based on the improved just-in-time learning (IJITL) technique is proposed for permanent magnet synchronous motor (PMSM) drive. Firstly, the traditional JITL technique is improved. The new IJITL technique has less computational burden and is more suitable for online identification of the PMSM drive system which is highly real-time compared to traditional JITL. In this way, the PMSM drive system is identified by IJITL technique, which provides information to an adaptive PI controller. Secondly, the adaptive PI controller is designed in discrete time domain which is composed of a PI controller and a supervisory controller. The PI controller is capable of automatically online tuning the control gains based on the gradient descent method and the supervisory controller is developed to eliminate the effect of the approximation error introduced by the PI controller upon the system stability in the Lyapunov sense. Finally, experimental results on the PMSM drive system show accurate identification and favorable tracking performance. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Effects of Laparascopic Hernia Repair by PIRS (Percutan Internal Ring Suturing) Technique on Testicular Artery Blood Supply.

    Science.gov (United States)

    Oral, Akgun; Karaca, Leyla; Ahiskalioglu, Ali; Yildiz, Abdullah; Yigiter, Murat; Celikkaya, Mehmet Emin; Chyndolotov, Temirlan; Salman, Ahmet Bedii

    2018-02-02

    Percutaneous internal ring suturing technique (PIRS) is a minimally invasive technique in pediatric inguinal hernia repair. In the present study, a negative effect on testicular blood flow using PIRS technique has been investigated. Forty male patients were included in the study prospectively. Two groups were formed as conventional open surgery (Group I) and PIRS technique (Group II). The resistive index (RI) value of the testicular artery was measured prospectively by using SMI (superb micro-vascular imaging) software with the color doppler ultrasound technique preoperatively and postoperatively at the first month. Inguinal hernia was present on the left in 35% (n = 14) of the patients and on the right in 65% (n = 26) of the patients. There was no statistically significant difference (p = 0.727) between Group I and II with regard to preoperative RI value (0.66 ± 0.07 vs. 0.66 ± 0.45, respectively). Similarly, there was no statistically significant difference (p = 0.220) between Group I and II with regard to the RI values measured at the postoperative first month (0.58 ± 0.04 vs. 0.60 ± 0.04, respectively). Although the postoperative RI values decreased compared to the preoperative values in both groups, this difference was not statistically significant. (p = 0.447 in Group I, and p = 0.175 in Group II for intragroup comparison). Besides PIRS technique has the advantages provided by all other laparoscopic techniques defined for inguinal hernia repair, there is no significant difference between this technique and conventional open surgery with regard to testicular blood flow. It is an innovative candidate technique instead of the open surgery method besides its additional advantages.

  20. Endovascular Aneurysm Repair Using a Reverse Chimney Technique in a Patient With Marfan Syndrome and Contained Ruptured Chronic Type B Dissection

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Kalender, Guenay; Heuschmid, Martin; Syha, Roland; Mangold, Stefanie; Claussen, Claus D.; Brechtel, Klaus

    2011-01-01

    We report endovascular thoracic and abdominal aneurysm repair (EVAR) with reverse chimney technique in a patient with contained ruptured type B dissection. EVAR seems feasible as a bailout option in Marfan patients with acute life-threatening disease.

  1. Motor current and leakage flux signature analysis technique for condition monitoring

    International Nuclear Information System (INIS)

    Pillai, M.V.; Moorthy, R.I.K.; Mahajan, S.C.

    1994-01-01

    Till recently analysis of vibration signals was the only means available to predict the state of health of plant equipment. Motor current and leakage magnetic flux signature analysis is acquiring importance as a technique for detection of incipient damages in the electrical machines and as a supplementary technique for diagnostics of driven equipment such as centrifugal and reciprocating pumps. The state of health of the driven equipment is assessed by analysing time signal, frequency spectrum and trend analysis. For example, the pump vane frequency, piston stroke frequency, gear frequency and bearing frequencies are indicated in the current and flux spectra. By maintaining a periodic record of the amplitudes of various frequency lines in the frequency spectra, it is possible to understand the trend of deterioration of parts and components of the pump. All problems arising out of inappropriate mechanical alignment of vertical pumps are easily identified by a combined analysis of current, flux and vibration signals. It is found that current signature analysis technique is a sufficient method in itself for the analysis of state of health of reciprocating pumps and compressors. (author). 10 refs., 4 figs

  2. Evolution of Employment and Qualifications in Motor Vehicle Repairs in France. Analysis of the Purpose of Coordinating the Overall System, Individual Organizations and Local Situations. Contribution for the CIRETOQ Meeting Organized at CEREQ/Marseille by CEDEFOP (November 20-21, 1995).

    Science.gov (United States)

    Bieganski, Richard; Cadet, Jean-Paul

    Considerations in analyzing and surveying the prospects for employment and training in the motor vehicle repair sector were explored by way of the example of France's motor vehicle repair sector. The discussion focused on the need to take the following steps: determine how labor is managed in the sector under consideration; consider the impact of…

  3. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

    Science.gov (United States)

    Bhatia, Sanjeev; Civitarese, David M; Turnbull, Travis Lee; LaPrade, Christopher M; Nitri, Marco; Wijdicks, Coen A; LaPrade, Robert F

    2016-03-01

    Complete radial tears of the medial meniscus have been reported to be functionally similar to a total meniscectomy. At present, there is no consensus on an ideal technique for repair of radial midbody tears of the medial meniscus. Prior attempts at repair with double horizontal mattress suture techniques have led to a reportedly high rate of incomplete healing or healing in a nonanatomic (gapped) position, which compromises the ability of the meniscus to withstand hoop stresses. A newly proposed 2-tunnel radial meniscal repair method will result in decreased gapping and increased ultimate failure loads compared with the double horizontal mattress suture repair technique under cyclic loading. Controlled laboratory study. Ten matched pairs of male human cadaveric knees (average age, 58.6 years; range, 48-66 years) were used. A complete radial medial meniscal tear was made at the junction of the posterior one-third and middle third of the meniscus. One knee underwent a horizontal mattress inside-out repair, while the contralateral knee underwent a radial meniscal repair entailing the same technique with a concurrent novel 2-tunnel repair. Specimens were potted and mounted on a universal testing machine. Each specimen was cyclically loaded 1000 times with loads between 5 and 20 N before experiencing a load to failure. Gap distances at the tear site and failure load were measured. The 2-tunnel repairs exhibited a significantly stronger ultimate failure load (median, 196 N; range, 163-212 N) than did the double horizontal mattress suture repairs (median, 106 N; range, 63-229 N) (P = .004). In addition, the 2-tunnel repairs demonstrated decreased gapping at all testing states (P meniscus significantly decrease the ability of the meniscus to dissipate tibiofemoral loads, predisposing patients to early osteoarthritis. Improving the ability to repair medial meniscal radial tears in a way that withstands cyclic loads and heals in an anatomic position could significantly

  4. Quality of Life after Ventral Hernia Repair with Endoscopic Component Separation Technique

    DEFF Research Database (Denmark)

    Thomsen, C Ø; Brøndum, T L; Jørgensen, Lars Nannestad

    2016-01-01

    of the hernia size. Demographic data, operative information, and postoperative complications were recorded. All patients completed two similar questionnaires regarding their function level, cosmetic satisfaction, analgesic medication, alcohol consumption, and self-estimated physical and mental health before...... center operated on with endoscopic components separation. MATERIAL AND METHODS: A total of 19 consecutive patients scheduled for open hernia repair with endoscopic components separation from October 2010 to June 2012 were included. All procedures included endoscopic components separation because...... and after the hernia repair. Patients were assessed as outpatient median 2 months and 16 months after operation for exclusion of hernia recurrence and completion of the postoperative questionnaire. RESULTS AND CONCLUSIONS: Operating room time was median 204 min and correlated significantly with the hernia...

  5. Rehabilitation of Motor Function after Stroke: A Multiple Systematic Review Focused on Techniques to Stimulate Upper Extremity Recovery

    Science.gov (United States)

    Hatem, Samar M.; Saussez, Geoffroy; della Faille, Margaux; Prist, Vincent; Zhang, Xue; Dispa, Delphine; Bleyenheuft, Yannick

    2016-01-01

    Stroke is one of the leading causes for disability worldwide. Motor function deficits due to stroke affect the patients' mobility, their limitation in daily life activities, their participation in society and their odds of returning to professional activities. All of these factors contribute to a low overall quality of life. Rehabilitation training is the most effective way to reduce motor impairments in stroke patients. This multiple systematic review focuses both on standard treatment methods and on innovating rehabilitation techniques used to promote upper extremity motor function in stroke patients. A total number of 5712 publications on stroke rehabilitation was systematically reviewed for relevance and quality with regards to upper extremity motor outcome. This procedure yielded 270 publications corresponding to the inclusion criteria of the systematic review. Recent technology-based interventions in stroke rehabilitation including non-invasive brain stimulation, robot-assisted training, and virtual reality immersion are addressed. Finally, a decisional tree based on evidence from the literature and characteristics of stroke patients is proposed. At present, the stroke rehabilitation field faces the challenge to tailor evidence-based treatment strategies to the needs of the individual stroke patient. Interventions can be combined in order to achieve the maximal motor function recovery for each patient. Though the efficacy of some interventions may be under debate, motor skill learning, and some new technological approaches give promising outcome prognosis in stroke motor rehabilitation. PMID:27679565

  6. Rehabilitation of motor function after stroke: a multiple systematic review focused on techniques to stimulate upper extremity recovery

    Directory of Open Access Journals (Sweden)

    Samar M Hatem

    2016-09-01

    Full Text Available Stroke is one of the leading causes for disability worldwide. Motor function deficits due to stroke affect the patients’ mobility, their limitation in daily life activities, their participation in society and their odds of returning to professional activities. All of these factors contribute to a low overall quality of life. Rehabilitation training is the most effective way to reduce motor impairments in stroke patients. This multiple systematic review focuses both on standard treatment methods and on innovating rehabilitation techniques used to promote upper extremity motor function in stroke patients. A total number of 5712 publications on stroke rehabilitation was systematically reviewed for relevance and quality with regards to upper extremity motor outcome. This procedure yielded 270 publications corresponding to the inclusion criteria of the systematic review. Recent technology-based interventions in stroke rehabilitation including non-invasive brain stimulation, robot-assisted training and virtual reality immersion are addressed. Finally, a decisional tree based on evidence from the literature and characteristics of stroke patients is proposed.At present, the stroke rehabilitation field faces the challenge to tailor evidence-based treatment strategies to the needs of the individual stroke patient. Interventions can be combined in order to achieve the maximal motor function recovery for each patient. Though the efficacy of some interventions may be under debate, motor skill learning and some new technological approaches give promising outcome prognosis in stroke motor rehabilitation.

  7. Remote manipulation techniques in the maintenance and repair of nuclear power plants

    International Nuclear Information System (INIS)

    Rininsland, H.; Boehme, G.

    1986-01-01

    Remote manipulation means the application of multi-purpose devices featuring high mobility and universal applicability. The paper describes such a remote manipulation system (manipulation vehicle MF1 and MF2, master-slave manipulator, TFTR maintenance manipulator) which can be used flexibly in the NNP during maintenance and repair and in incident and accident situations. Connecting elements and tools can be redesigned for remote manipulation to meet the specific application environments. (DG) [de

  8. Open-Phase Fault Tolerance Techniques of Five-Phase Dual-Rotor Permanent Magnet Synchronous Motor

    Directory of Open Access Journals (Sweden)

    Jing Zhao

    2015-11-01

    Full Text Available Multi-phase motors are gaining more attention due to the advantages of good fault tolerance capability and high power density, etc. By applying dual-rotor technology to multi-phase machines, a five-phase dual-rotor permanent magnet synchronous motor (DRPMSM is researched in this paper to further promote their torque density and fault tolerance capability. It has two rotors and two sets of stator windings, and it can adopt a series drive mode or parallel drive mode. The fault-tolerance capability of the five-phase DRPMSM is researched. All open circuit fault types and corresponding fault tolerance techniques in different drive modes are analyzed. A fault-tolerance control strategy of injecting currents containing a certain third harmonic component is proposed for five-phase DRPMSM to ensure performance after faults in the motor or drive circuit. For adjacent double-phase faults in the motor, based on where the additional degrees of freedom are used, two different fault-tolerance current calculation schemes are adopted and the torque results are compared. Decoupling of the inner motor and outer motor is investigated under fault-tolerant conditions in parallel drive mode. The finite element analysis (FMA results and co-simulation results based on Simulink-Simplorer-Maxwell verify the effectiveness of the techniques.

  9. Comparative Study of Time-Frequency Decomposition Techniques for Fault Detection in Induction Motors Using Vibration Analysis during Startup Transient

    Directory of Open Access Journals (Sweden)

    Paulo Antonio Delgado-Arredondo

    2015-01-01

    Full Text Available Induction motors are critical components for most industries and the condition monitoring has become necessary to detect faults. There are several techniques for fault diagnosis of induction motors and analyzing the startup transient vibration signals is not as widely used as other techniques like motor current signature analysis. Vibration analysis gives a fault diagnosis focused on the location of spectral components associated with faults. Therefore, this paper presents a comparative study of different time-frequency analysis methodologies that can be used for detecting faults in induction motors analyzing vibration signals during the startup transient. The studied methodologies are the time-frequency distribution of Gabor (TFDG, the time-frequency Morlet scalogram (TFMS, multiple signal classification (MUSIC, and fast Fourier transform (FFT. The analyzed vibration signals are one broken rotor bar, two broken bars, unbalance, and bearing defects. The obtained results have shown the feasibility of detecting faults in induction motors using the time-frequency spectral analysis applied to vibration signals, and the proposed methodology is applicable when it does not have current signals and only has vibration signals. Also, the methodology has applications in motors that are not fed directly to the supply line, in such cases the analysis of current signals is not recommended due to poor current signal quality.

  10. End-to-side nerve suture – a technique to repair peripheral nerve ...

    African Journals Online (AJOL)

    Lateral sprouting from an intact nerve into an attached nerve does occur, and functional recovery (sensory and motor) has been demonstrated. We have demonstrated conclusively that ETSNS in the human is a viable option in treating peripheral nerve injuries, including injuries to the brachial plexus. Among the many ...

  11. A novel technique for phase synchrony measurement from the complex motor imaginary potential of combined body and limb action

    Science.gov (United States)

    Zhou, Zhong-xing; Wan, Bai-kun; Ming, Dong; Qi, Hong-zhi

    2010-08-01

    In this study, we proposed and evaluated the use of the empirical mode decomposition (EMD) technique combined with phase synchronization analysis to investigate the human brain synchrony of the supplementary motor area (SMA) and primary motor area (M1) during complex motor imagination of combined body and limb action. We separated the EEG data of the SMA and M1 into intrinsic mode functions (IMFs) using the EMD method and determined the characteristic IMFs by power spectral density (PSD) analysis. Thereafter, the instantaneous phases of the characteristic IMFs were obtained by the Hilbert transformation, and the single-trial phase-locking value (PLV) features for brain synchrony measurement between the SMA and M1 were investigated separately. The classification performance suggests that the proposed approach is effective for phase synchronization analysis and is promising for the application of a brain-computer interface in motor nerve reconstruction of the lower limbs.

  12. Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

    Science.gov (United States)

    Cha, Jong Hyun; Lee, Yong Hae; Ruy, Wan Chul; Roe, Young; Moon, Myung Ho

    2016-01-01

    Background Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from 1.0952±0.0662 (ranging from 0.9917 to 1.2509) preoperatively to 0.9942±0.0427 (ranging from 0.9394 to 1.0680) postoperatively. Conclusion The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system. PMID:28913272

  13. Clinical Outcomes and Complications of Percutaneous Achilles Repair System Versus Open Technique for Acute Achilles Tendon Ruptures.

    Science.gov (United States)

    Hsu, Andrew R; Jones, Carroll P; Cohen, Bruce E; Davis, W Hodges; Ellington, J Kent; Anderson, Robert B

    2015-11-01

    Limited incision techniques for acute Achilles tendon ruptures have been developed in recent years to improve recovery and reduce postoperative complications compared with traditional open repair. The purpose of this retrospective cohort study was to analyze the clinical outcomes and postoperative complications between acute Achilles tendon ruptures treated using a percutaneous Achilles repair system (PARS [Arthrex, Inc, Naples, FL]) versus open repair and evaluate the overall outcomes for operatively treated Achilles ruptures. Between 2005 and 2014, 270 consecutive cases of operatively treated acute Achilles tendon ruptures were reviewed (101 PARS, 169 open). Patients with Achilles tendinopathy, insertional ruptures, chronic tears, or less than 3-month follow-up were excluded. Operative treatment consisted of a percutaneous technique (PARS) using a 2-cm transverse incision with FiberWire (Arthrex, Inc, Naples, FL) sutures or open repair using a 5- to 8-cm posteromedial incision with FiberWire in a Krackow fashion reinforced with absorbable sutures. Patient demographics were recorded along with medical comorbidities, activity at injury, time from injury to surgery, length of follow-up, return to baseline activities by 5 months, and postoperative complications. The most common activity during injury for both groups was basketball (PARS: 39%, open: 47%). A greater number of patients treated with PARS were able to return to baseline physical activities by 5 months compared with the open group (PARS: 98%, open: 82%; P = .0001). There were no significant differences (P > .05) between groups in rates of rerupture (P = 1.0), sural neuritis (P = .16), wound dehiscence (P = .74), superficial (P = .29) and/or deep infection (P = .29), or reoperation (P = .13). There were no deep vein thromboses (DVTs) or reruptures in either group. In the PARS group, there were no cases of sural neuritis, 3 cases (3%) of superficial wound dehiscence, and 2 reoperations (2%) for superficial

  14. A novel silk suture-assisted laparoscopic technique for the repair of a gastrocolic fistula in a pediatric patient

    Directory of Open Access Journals (Sweden)

    Seher Mughal

    2016-10-01

    Full Text Available Percutaneous placement of gastrostomy was first described in 1980. Since then it has become widely used in pediatric surgery throughout the world. Inherent in the technique is the possibility of inadvertent damage to adjacent anatomical structures, most commonly the transverse colon. Management previously had involved laparotomy and correction of the gastrocolic fistula. Here we describe a novel laparoscopic approach to the repair of a gastrocolic fistula following percutaneous gastrostomy, avoiding the morbidity of laparotomy in an immunocompromised patient with a rotund abdomen secondary to steroid usage.

  15. Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model.

    Science.gov (United States)

    Quigley, Ryan J; Gupta, Akash; Oh, Joo-Han; Chung, Kyung-Chil; McGarry, Michelle H; Gupta, Ranjan; Tibone, James E; Lee, Thay Q

    2013-08-01

    The transosseous-equivalent (TOE) rotator cuff repair technique increases failure loads and contact pressure and area between tendon and bone compared to single-row (SR) and double-row (DR) repairs, but no study has investigated if this translates into improved healing in vivo. We hypothesized that a TOE repair in a rabbit chronic rotator cuff tear model would demonstrate a better biomechanical profile than SR and DR repairs after 12 weeks of healing. A two-stage surgical procedure was performed on 21 New Zealand White Rabbits. The right subscapularis tendon was transected and allowed to retract for 6 weeks to simulate a chronic tear. Repair was done with the SR, DR, or TOE technique and allowed to heal for 12 weeks. Cyclic loading and load to failure biomechanical testing was then performed. The TOE repair showed greater biomechanical characteristics than DR, which in turn were greater than SR. These included yield load (p repair of a chronic, retracted rotator cuff tear, the TOE technique was the strongest biomechanical construct after healing followed by DR with SR being the weakest. Copyright © 2013 Orthopaedic Research Society.

  16. Tensile strength of the pullout repair technique for the medial meniscus posterior root tear: a porcine study.

    Science.gov (United States)

    Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi

    2017-10-01

    The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.

  17. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    Science.gov (United States)

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  18. Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations.

    Science.gov (United States)

    Pauly, Stephan; Kieser, Bettina; Schill, Alexander; Gerhardt, Christian; Scheibel, Markus

    2010-10-01

    Biomechanical comparison of different suture-bridge configurations of the medial row with respect to initial construct stability (time 0, porcine model). In 40 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected from their insertions. All specimens were operated on by use of the suture-bridge technique, only differing in terms of the medial-row suture-grasping configuration, and randomized into 4 groups: (1) single-mattress (SM) technique, (2) double-mattress (DM) technique, (3) cross-stitch (CS) technique, and (4) double-pulley (DP) technique. Identical suture anchors were used for all specimens (medial: Bio-Corkscrew FT 5.5 [Arthrex, Naples, FL]; lateral: Bio-PushLock 3.5 [Arthrex]). All repairs were cyclically loaded from 10 to 60 N until 10 to 200 N (20-N stepwise increase after 50 cycles each) with a material testing machine. Forces at 3 and 5 mm of gap formation, mode of failure, and maximum load to failure were recorded. The DM technique had the highest ultimate tensile strength (368.6 ± 99.5 N) compared with the DP (248.4 ± 122.7 N), SM (204.3 ± 90 N), and CS (184.9 ± 63.8 N) techniques (P = .004). The DM technique provided maximal force resistance until 3 and 5 mm of gap formation (90.0 ± 18.1 N and 128.0 ± 32.3 N, respectively) compared with the CS (72 ± 8.9 N and 108 ± 20.2 N, respectively), SM (66.0 ± 8.9 N and 90.0 ± 26.9 N, respectively), and DP (62.2 ± 6.2 N and 71 ± 13.2 N, respectively) techniques (P biomechanical construct stability at time 0 in this porcine ex vivo model. This technique increases initial stability and resistance to suture cutting through the rotator cuff tendon after arthroscopic suture-bridge repair. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Advanced Materials and Fabrication Techniques for the Orion Attitude Control Motor

    Science.gov (United States)

    Gorti, Sridhar; Holmes, Richard; O'Dell, John; McKechnie, Timothy; Shchetkovskiy, Anatoliy

    2013-01-01

    Rhenium, with its high melting temperature, excellent elevated temperature properties, and lack of a ductile-to-brittle transition temperature (DBTT), is ideally suited for the hot gas components of the ACM (Attitude Control Motor), and other high-temperature applications. However, the high cost of rhenium makes fabricating these components using conventional fabrication techniques prohibitive. Therefore, near-net-shape forming techniques were investigated for producing cost-effective rhenium and rhenium alloy components for the ACM and other propulsion applications. During this investigation, electrochemical forming (EL-Form ) techniques were evaluated for producing the hot gas components. The investigation focused on demonstrating that EL-Form processing techniques could be used to produce the ACM flow distributor. Once the EL-Form processing techniques were established, a representative rhenium flow distributor was fabricated, and samples were harvested for material properties testing at both room and elevated temperatures. As a lower cost and lighter weight alternative to an all-rhenium component, rhenium- coated graphite and carbon-carbon were also evaluated. The rhenium-coated components were thermal-cycle tested to verify that they could withstand the expected thermal loads during service. High-temperature electroforming is based on electrochemical deposition of compact layers of metals onto a mandrel of the desired shape. Mandrels used for electro-deposition of near-net shaped parts are generally fabricated from high-density graphite. The graphite mandrel is easily machined and does not react with the molten electrolyte. For near-net shape components, the inner surface of the electroformed part replicates the polished graphite mandrel. During processing, the mandrel itself becomes the cathode, and scrap or refined refractory metal is the anode. Refractory metal atoms from the anode material are ionized in the molten electrolytic solution, and are deposited

  20. Evaluation of native hyaline cartilage and repair tissue after two cartilage repair surgery techniques with 23Na MR imaging at 7 T: initial experience.

    Science.gov (United States)

    Zbýň, S; Stelzeneder, D; Welsch, G H; Negrin, L L; Juras, V; Mayerhoefer, M E; Szomolanyi, P; Bogner, W; Domayer, S E; Weber, M; Trattnig, S

    2012-08-01

    To compare the sodium normalized mean signal intensity (NMSI) values between patients after bone marrow stimulation (BMS) and matrix-associated autologous chondrocyte transplantation (MACT) cartilage repair procedures. Nine BMS and nine MACT patients were included. Each BMS patient was matched with one MACT patient according to age [BMS 36.7 ± 10.7 (mean ± standard deviation) years; MACT 36.9 ± 10.0 years], postoperative interval (BMS 33.5 ± 25.3 months; MACT 33.2 ± 25.7 months), and defect location. All magnetic resonance imaging (MRI) measurements were performed on a 7 T system. Proton images served for morphological evaluation of repair tissue using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system. Sodium NMSI values in the repair area and morphologically normal cartilage were calculated. Clinical outcome was assessed right after MRI. Analysis of covariance, t-tests, and Pearson correlation coefficients were evaluated. Sodium NMSI was significantly lower in BMS (P = 0.004) and MACT (P = 0.006) repair tissue, compared to reference cartilage. Sodium NMSI was not different between the reference cartilage in MACT and BMS patients (P = 0.664), however it was significantly higher in MACT than in BMS repair tissue (P = 0.028). Better clinical outcome was observed in BMS than in MACT patients. There was no difference between MOCART scores for MACT and BMS patients (P = 0.915). We did not observe any significant correlation between MOCART score and sodium repair tissue NMSI (r = -0.001; P = 0.996). Our results suggest higher glycosaminoglycan (GAG) content, and therefore, repair tissue of better quality in MACT than in BMS patients. Sodium imaging might be beneficial in non-invasive evaluation of cartilage repair surgery efficacy. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  1. Third-Order Spectral Techniques for the Diagnosis of Motor Bearing Condition Using Artificial Neural Networks

    Science.gov (United States)

    Yang, D.-M.; Stronach, A. F.; MacConnell, P.; Penman, J.

    2002-03-01

    This paper addresses the development of a novel condition monitoring procedure for rolling element bearings which involves a combination of signal processing, signal analysis and artificial intelligence methods. Seven approaches based on power spectrum, bispectral and bicoherence vibration analyses are investigated as signal pre-processing techniques for application in the diagnosis of a number of induction motor rolling element bearing conditions. The bearing conditions considered are a normal bearing and bearings with cage and inner and outer race faults. The vibration analysis methods investigated are based on the power spectrum, the bispectrum, the bicoherence, the bispectrum diagonal slice, the bicoherence diagonal slice, the summed bispectrum and the summed bicoherence. Selected features are extracted from the vibration signatures so obtained and these are used as inputs to an artificial neural network trained to identify the bearing conditions. Quadratic phase coupling (QPC), examined using the magnitude of bispectrum and bicoherence and biphase, is shown to be absent from the bearing system and it is therefore concluded that the structure of the bearing vibration signatures results from inter-modulation effects. In order to test the proposed procedure, experimental data from a bearing test rig are used to develop an example diagnostic system. Results show that the bearing conditions examined can be diagnosed with a high success rate, particularly when using the summed bispectrum signatures.

  2. A Contact Pressure Analysis Comparing an All-Inside and Inside-Out Surgical Repair Technique for Bucket-Handle Medial Meniscus Tears.

    Science.gov (United States)

    Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B

    2017-10-01

    To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P contact pressure at all flexion angles (all P contact pressure at all flexion angles (all P contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P contact area at 60° and 90° and peak contact pressure at 90° (both P contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of

  3. Salvage Flexor Hallucis Longus Transfer for a Failed Achilles Repair: Endoscopic Technique.

    Science.gov (United States)

    Gonçalves, Sérgio; Caetano, Rubén; Corte-Real, Nuno

    2015-10-01

    Flexor hallucis longus (FHL) transfer is a well-established treatment option in failed Achilles tendon (AT) repair and has been routinely performed as an open procedure. We detail the surgical steps needed to perform an arthroscopic transfer of the FHL for a chronic AT rupture. The FHL tendon is harvested as it enters in its tunnel beneath the sustentaculum tali; a tunnel is then drilled in the calcaneus as near to the AT footprint as possible. By use of a suture-passing device, the free end of the FHL is advanced to the plantar aspect of the foot. After adequate tension is applied to the construct, the tendon is fixed in place with an interference screw in an inside-out fashion. This minimally invasive approach is a safe and valid alternative to classic open procedures with the obvious advantages of preserving the soft-tissue envelope and using a biologically intact tendon.

  4. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    Science.gov (United States)

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  5. Humeral repair in birds by guided tissue regeneration and external and internal associated fixation techniques

    International Nuclear Information System (INIS)

    Delogu, M.

    1993-01-01

    Ten pigeons (Columba livia domestic form) with humeral diaphyseal fracture were treated with external and internal fixation techniques (Boston technique and intamedullary pin). Longitudinal space was intentionally left between fracture surfaces during osteosynthesis. This space was filled with bovine lyophilized collagen, set around an intramedullary pin, in five samples. Ossification process was checked by radiography every seven days. Results show the utility of this technique in pneumatic bird bones. In fact, shortening control and callus formation facility were observed [it

  6. Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.

    Science.gov (United States)

    DeHaan, Alexander M; Axelrad, Thomas W; Kaye, Elizabeth; Silvestri, Lorenzo; Puskas, Brian; Foster, Timothy E

    2012-05-01

    The advantage of single-row versus double-row arthroscopic rotator cuff repair techniques has been a controversial issue in sports medicine and shoulder surgery. There is biomechanical evidence that double-row techniques are superior to single-row techniques; however, there is no clinical evidence that the double-row technique provides an improved functional outcome. When compared with single-row rotator cuff repair, double-row fixation, although biomechanically superior, has no clinical benefit with respect to retear rate or improved functional outcome. Systematic review. The authors reviewed prospective studies of level I or II clinical evidence that compared the efficacy of single- and double-row rotator cuff repairs. Functional outcome scores included the American Shoulder and Elbow Surgeons (ASES) shoulder scale, the Constant shoulder score, and the University of California, Los Angeles (UCLA) shoulder rating scale. Radiographic failures and complications were also analyzed. A test of heterogeneity for patient demographics was also performed to determine if there were differences in the patient profiles across the included studies. Seven studies fulfilled our inclusion criteria. The test of heterogeneity across these studies showed no differences. The functional ASES, Constant, and UCLA outcome scores revealed no difference between single- and double-row rotator cuff repairs. The total retear rate, which included both complete and partial retears, was 43.1% for the single-row repair and 27.2% for the double-row repair (P = .057), representing a trend toward higher failures in the single-row group. Through a comprehensive literature search and meta-analysis of current arthroscopic rotator cuff repairs, we found that the single-row repairs did not differ from the double-row repairs in functional outcome scores. The double-row repairs revealed a trend toward a lower radiographic proven retear rate, although the data did not reach statistical significance. There

  7. A combined technique using a muscular flap and endobronchial stent to repair complex broncho-oesophageal fistulae supported by ECMO.

    Science.gov (United States)

    Baste, Jean-Marc; Haddad, Laura; Philouze, Guillaume

    2018-02-01

    Certain broncho-oesophageal fistulae require surgical repair. Herein, we describe an innovative surgical technique combining intercostal flap and endobronchial stenting. Two patients, each with a with complex broncho-oesophageal fistula 2 years after radio-chemotherapy, were hospitalised for severe respiratory infection and extension of the fistula despite previous endoscopic treatment. The first patient presented with respiratory distress (ARDS). She had emergency surgery under extra corporeal membrane oxygenation: oesophagectomy and reconstruction of the left bronchus by a vascularised intercostal flap. Stenting was performed on day 10, due to persistence of the fistula. At 3 months the bronchus was healed, but the patient died of cerebral bleeding. For the second patient, repair was proposed before severe ARDS with the same surgical and ventilatory strategy and a stent was preventively inserted after surgery. After 3 months, the stent was removed and the left bronchus was healed. Complex post-radiotherapy broncho-oesophageal fistulae should be treated surgically before respiratory complications arise, by combining reconstruction with a vascularised flap and transient stenting.

  8. Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Juszczak, Maciej T. [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Bratby, Mark J. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Sideso, Ediri [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Anthony, Susan; Tapping, Charles R. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Handa, Ashok; Darby, Christopher R.; Perkins, Jeremy [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Uberoi, Raman [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom)

    2015-08-15

    PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

  9. A comparison of the techniques of direct pars interarticularis repairs for spondylolysis and low-grade spondylolisthesis: a meta-analysis.

    Science.gov (United States)

    Mohammed, Nasser; Patra, Devi Prasad; Narayan, Vinayak; Savardekar, Amey R; Dossani, Rimal Hanif; Bollam, Papireddy; Bir, Shyamal; Nanda, Anil

    2018-01-01

    OBJECTIVE Spondylosis with or without spondylolisthesis that does not respond to conservative management has an excellent outcome with direct pars interarticularis repair. Direct repair preserves the segmental spinal motion. A number of operative techniques for direct repair are practiced; however, the procedure of choice is not clearly defined. The present study aims to clarify the advantages and disadvantages of the different operative techniques and their outcomes. METHODS A meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The following databases were searched: PubMed, Cochrane Library, Web of Science, and CINAHL ( Cumulative Index to Nursing and Allied Health Literature). Studies of patients with spondylolysis with or without low-grade spondylolisthesis who underwent direct repair were included. The patients were divided into 4 groups based on the operative technique used: the Buck repair group, Scott repair group, Morscher repair group, and pedicle screw-based repair group. The pooled data were analyzed using the DerSimonian and Laird random-effects model. Tests for bias and heterogeneity were performed. The I 2 statistic was calculated, and the results were analyzed. Statistical analysis was performed using StatsDirect version 2. RESULTS Forty-six studies consisting of 900 patients were included in the study. The majority of the patients were in their 2nd decade of life. The Buck group included 19 studies with 305 patients; the Scott group had 8 studies with 162 patients. The Morscher method included 5 studies with 193 patients, and the pedicle group included 14 studies with 240 patients. The overall pooled fusion, complication, and outcome rates were calculated. The pooled rates for fusion for the Buck, Scott, Morscher, and pedicle screw groups were 83.53%, 81.57%, 77.72%, and 90.21%, respectively. The pooled complication rates for the Buck, Scott, Morscher, and pedicle

  10. Clinical Results of Arthroscopic Repair of Isolated Longitudinal Tear of Medial Meniscus by Vertical Cruciate Double Mattress Sutures with Outside-in Technique

    Directory of Open Access Journals (Sweden)

    Seyied Hamid Barzgar

    2013-09-01

    Full Text Available Introduction : Meniscal tears are one of the most common injuries treated by arthroscopic techniques. Arthroscopic meniscal repair is an accepted way of treatment for meniscal tears. Different arthroscopic techniques for meniscal repair are: inside-out, outside-in and all inside. In the first 2 techniques, meniscus is repaired by sutures and in the later by suture or by commercial ready implants . The goal of current study is assessing clinical results of arthroscopic repair of longitudinal meniscal tears with vertical cruciate double mattress sutures by outside-in technique after 9 months.   Methods: In this case series study, in 13 patients having criteria for engaging the study with longitudinal isolated meniscus tear, arthroscopic meniscal repair was done with vertical cruciate double mattress sutures by outside-in technique and patients were followed for 9 months.   Results: Of 13 patients, there were 12 males (92.3% and one female (7.7% aged 15-38 (average 28.3 years. In follow up period, there was one case (7.7% of irritation by subcutaneous knot. There was not any failure of repair. Average Lysholm score increased from 55.23 to 91.23 after 9 months of follow up, which was statistically significant (p<0.001. At the end of follow up period, there was not any medial joint line tenderness of knee, giving way or significant effusion or pain.   Conclusion: This study shows that this technique has a good short term outcome with no failure and low complications but it is necessary to do more long term studies to prove it.

  11. Conditioning stimulation techniques for enhancement of transcranially elicited evoked motor responses

    NARCIS (Netherlands)

    Journee, H. -L.; Polak, H. E.; De Kleuver, M.

    2007-01-01

    Introduction. - In spite of the use of multipulse, transcranial electrical stimulation (TES) is still insufficient in a subgroup of patients to elicit motor-evoked potentials during intraoperative neurophysiological monitoring (IONM). Classic facilitation methods used in awake patients are precluded

  12. Fault detection and diagnosis in induction motor using artificial intelligence technique

    Directory of Open Access Journals (Sweden)

    Khireddine M.S.

    2014-01-01

    Full Text Available Induction machines play a vital role in industry and there is a strong demand for their reliable and safe operation. The online monitoring of induction motors is becoming increasingly important. The main difficulty in this task is the lack of an accurate analytical model to describe a faulty motor. Faults and failures of induction machines can lead to excessive downtimes and generate large losses in terms of maintenance and lost revenues, and this motivates the examination of on-line condition monitoring. The major difficulty is the lack of an accurate model that describes a fault motor. Moreover, experienced engineers are often required to interpret measurement data that are frequently inconclusive. A fuzzy logic approach may help to diagnose induction motor faults. In fact, fuzzy logic is reminiscent of human thinking processes and natural language enabling decisions to be made based on vague information.

  13. Pole Shape Optimization of Permanent Magnet Synchronous Motors Using the Reduced Basis Technique

    Directory of Open Access Journals (Sweden)

    A. Jabbari

    2010-03-01

    Full Text Available In the present work, an integrated method of pole shape design optimization for reduction of torque pulsation components in permanent magnet synchronous motors is developed. A progressive design process is presented to find feasible optimal shapes. This method is applied on the pole shape optimization of two prototype permanent magnet synchronous motors, i.e., 4-poles/6-slots and 4-poles-12slots.

  14. Mitek Anchor System: a new technique for tenodesis and ligamentous repair of the foot and ankle.

    Science.gov (United States)

    Pederson, B; Tesoro, D; Wertheimer, S J; Coraci, M

    1991-01-01

    The authors present an alternative method for securing tendon and ligaments to bone, utilizing the Mitek Anchor System. The description of the Mitek system and technique of application is presented. Technical simplicity and ease of adaptability within the foot and ankle are distinct advantages of this System.

  15. Extended aortic repair using frozen elephant trunk technique for Marfan syndrome with acute aortic dissection.

    Science.gov (United States)

    Uchida, Naomichi; Katayama, Akira; Kuraoka, Masatsugu; Katayama, Keijiro; Takahashi, Shinya; Takasaki, Taiichi; Sueda, Taijiro

    2013-01-01

    The aim of this study was to analyze midterm results of frozen elephant trunk technique for Marfan syndrome with acute aortic dissection. Between February 1999 and August 2011 we performed arch replacement uisng frozen elephant trunk technique for acute aortic dissection in 8 patients with Marfan syndrome containing two complicated type B dissections and six type A dissections.Five patients compromised annulo-aortic ectasia who performed Bentall operation. No patients died in the initial operation. Fate of false lumen on the stent graft border was expressed by CT scan follow-up that were patent in 0, thrombosis in 5 and absorption in 3 patients. One patient who had new aortic dissection 8 years after initial surgery required the Crawford V operation. Ten-years-survival rate was 100% and ten years-event free rate was 67%. Frozen elephant trunk technique was feasible for Marfan syndrome with acute aortic dissection and might become alternative prophylactic treatment to the downstream aorta for acute aortic dissection.

  16. Repair of Unstable Posterior Sternoclavicular Dislocation Using Nonabsorbable Tape Suture and Tension Band Technique: A Case Report with Good Results

    Directory of Open Access Journals (Sweden)

    Ekrem Aydın

    2015-01-01

    Full Text Available Posterior sternoclavicular joint dislocation (PSCJD is quite a rare condition. Nearly half of the closed reduction attempts fail due to various reasons. In this paper, we present a 25-year-old male patient who was admitted to the emergency department in our hospital after having a motor-vehicle accident. It was decided to do PSCJD after physical and imaging studies. Following necessary preparations, closed reduction was attempted with abduction-traction maneuver under general anesthesia; however, adequate stabilization could not be achieved and redislocation was detected during control. Therefore, joint was stabilized with tension band technique using 6 mm polyamide nonabsorbable type suture during open reduction. Painless and complete range of motion in shoulder was achieved at the postoperative 10th week.

  17. A novel collagen film with micro-rough surface structure for corneal epithelial repair fabricated by freeze drying technique

    International Nuclear Information System (INIS)

    Liu, Yang; Ren, Li; Wang, Yingjun

    2014-01-01

    Highlights: • Collagen film with micro-rough surface is fabricated by freeze drying technique. • The film has suitable water uptake capability and toughness performance. • The film has good optical performance. • Human corneal epithelial cells studies confirmed the biocompatibility of the film. - Abstract: Corneal epithelial defect is a common disease and keratoplasty is a common treatment method. A collagen film with micro-rough surface was fabricated through a simple freeze drying technique in this study. Compared with the air-dried collagen film (AD-Col), this freeze-dried collagen film (FD-Col) has a more suitable water uptake capability (about 85.5%) and toughness performance. Both of the two films have good optical properties and the luminousness of them is higher than 80%. Besides, the adhesion and proliferation rate of human corneal epithelial cells on the micro-rough surface of FD-Col film is higher than that on the smooth surface of AD-Col film. The results indicate that this FD-Col film may have potential applications for corneal epithelial repair

  18. A novel collagen film with micro-rough surface structure for corneal epithelial repair fabricated by freeze drying technique

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 (China); Ren, Li, E-mail: psliren@scut.edu.cn [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 (China); Wang, Yingjun, E-mail: imwangyj@163.com [School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); National Engineering Research Center for Tissue Restoration and Reconstruction, Guangzhou 510006 (China); Guangdong Province Key Laboratory of Biomedical Engineering, South China University of Technology, Guangzhou 510006 (China)

    2014-05-01

    Highlights: • Collagen film with micro-rough surface is fabricated by freeze drying technique. • The film has suitable water uptake capability and toughness performance. • The film has good optical performance. • Human corneal epithelial cells studies confirmed the biocompatibility of the film. - Abstract: Corneal epithelial defect is a common disease and keratoplasty is a common treatment method. A collagen film with micro-rough surface was fabricated through a simple freeze drying technique in this study. Compared with the air-dried collagen film (AD-Col), this freeze-dried collagen film (FD-Col) has a more suitable water uptake capability (about 85.5%) and toughness performance. Both of the two films have good optical properties and the luminousness of them is higher than 80%. Besides, the adhesion and proliferation rate of human corneal epithelial cells on the micro-rough surface of FD-Col film is higher than that on the smooth surface of AD-Col film. The results indicate that this FD-Col film may have potential applications for corneal epithelial repair.

  19. Preservation of bursal-sided tendon in partial-thickness articular-sided rotator cuff tears: a novel arthroscopic transtendon anatomic repair technique.

    Science.gov (United States)

    Shin, Sang-Jin; Jeong, Jae-Hoon; Jeon, Yoon Sang; Kim, Rag Gyu

    2016-12-01

    The purpose of this study was to introduce a novel arthroscopic transtendon anatomic repair technique that spares the intact bursal-sided tendon in articular-sided partial-thickness rotator cuff tears (PTRCT) and to present shoulder functional outcomes in patients with symptomatic articular-sided PCRCT that involves more than 50 % of its thickness after arthroscopic repair using a novel technique. Eighteen patients with symptomatic articular-sided PCRCT involving more than 50 % of the tendon's thickness underwent arthroscopic repair using a devised technique. The devised technique restores only the torn articular portion of the rotator cuff at the anatomical footprint using a suture anchor, and preserves the integrity of the corresponding bursal-sided tendon by tying knots at the most lateral bursal side on the subacromial space. Clinical and functional outcome using ASES and Constant scores were evaluated. The structural integrity of the rotator cuff was evaluated by MRI at 6 months postoperatively. Pain relief and shoulder functional outcomes were encouraging during the recovery phase after operation. ASES (preoperative 54.0 ± 10.3 to postoperative 92.6 ± 8.0), Constant score (61.2 ± 8.5-88.0 ± 5.3), VAS for pain (4.9 ± 2.6-0.6 ± 0.7) improved significantly after arthroscopic transtendon anatomic repair (p rotator cuff retears on 6-month MRI. No complications related to surgical procedures had occurred. The devised technique of arthroscopic transtendon repair provided satisfactory functional outcomes without postoperative discomforts. This technique minimizes over-tightening of the articular layer and reduces tension mismatches between the articular and bursal layers, which are considered as important factors for improvement of postoperative shoulder motion.

  20. Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears.

    Science.gov (United States)

    Zhang, Chun-Gang; Zhao, De-Wei; Wang, Wei-Ming; Ren, Ming-Fa; Li, Rui-Xin; Yang, Sheng; Liu, Yu-Peng

    2010-11-01

    For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of ≤ 45° into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Gap formation for the transtendon single-row repair was significantly smaller (P row repair for the first cycle ((1.74 ± 0.38) mm vs. (2.86 ± 0.46) mm, respectively) and the last cycle ((3.77 ± 0.45) mm vs. (5.89 ± 0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P row repair. Also, it had a higher mean ultimate tensile load and stiffness. For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation.

  1. Rehabilitation of patients with motor disabilities using computer vision based techniques

    Directory of Open Access Journals (Sweden)

    Alejandro Reyes-Amaro

    2012-05-01

    Full Text Available In this paper we present details about the implementation of computer vision based applications for the rehabilitation of patients with motor disabilities. The applications are conceived as serious games, where the computer-patient interaction during playing contributes to the development of different motor skills. The use of computer vision methods allows the automatic guidance of the patient’s movements making constant specialized supervision unnecessary. The hardware requirements are limited to low-cost devices like usual webcams and Netbooks.

  2. Pedicled Descending Branch Latissimus Dorsi Mini-flap for Repairing Partial Mastectomy Defect: A New Technique

    Directory of Open Access Journals (Sweden)

    Ruizhao Cai, M.D.

    2018-03-01

    Full Text Available Summary:. Volume loss is 1 of the major factors influencing cosmetic outcomes of breast after partial mastectomy (PM, especially for smaller breasts, and therefore, volume replacement is critical for optimizing the final aesthetic outcome. We present a novel technique of raising a pedicled descending branch latissimus dorsi (LD mini-flap for reconstruction of PM defects via an axillary incision. After PM, the LD mini-flap is harvested through the existing axillary incision of the axillary dissection or the sentinel lymph node biopsy. The descending branches of thoracodorsal vessels and nerve are carefully identified and isolated. The transverse branches are protected to maintain muscle innervation and function. The LD muscle is then undermined posteriorly and inferiorly to create a submuscular pocket and a subcutaneous pocket between LD muscle and superficial fascia. Once the submuscular plane is created, the muscle is divided along the muscle fibers from the deep surface including a layer of fat above the muscle. Finally, the LD mini-flap is transferred to the breast defect. Given the limited length and mobility of the LD mini-flap, this approach is best utilized for lateral breast defects. However, for medial defects, the lateral breast tissue is rearranged to reconstruct the medial breast defect, and an LD mini-flap is then used to reconstruct the lateral breast donor site. This technique can therefore be employed to reconstruct all quadrants of the breast and can provide aesthetic outcomes without scars on the back, with minimal dysfunction of LD muscle.

  3. Factors associated with clinical and structural outcomes after arthroscopic rotator cuff repair with a suture bridge technique in medium, large, and massive tears.

    Science.gov (United States)

    Choi, Sungwook; Kim, Myung Ku; Kim, Gyeong Min; Roh, Young-Ho; Hwang, Im Kyung; Kang, Hyunseong

    2014-11-01

    This study was conducted to evaluate clinical outcomes, maintenance of repair integrity, and retear rate after arthroscopic rotator cuff repair by a suture bridge technique among patients with medium, large, and massive rotator cuff tears. We evaluated 147 patients who had undergone arthroscopic rotator cuff repair. Clinical and functional evaluations were performed with the Constant and University of California-Los Angeles scores. All patients were confirmed to have magnetic resonance imaging evidence of tendon healing at least 12 months postoperatively. The average postoperative time to follow-up magnetic resonance imaging was 23.4 months (range, 12-48 months). A total of 25 (17.0%) retears were observed. All clinical outcome scores were improved significantly at follow-up. Larger intraoperative tear sizes were correlated with higher retear rates. The incidence of retear was also higher in cases in which the preoperative fatty degeneration grade was higher. The incidence of retear increased with age and in the heavy worker group (e.g., farmers, carriers, car mechanics) but was not statistically significant. Arthroscopic rotator cuff repair by a suture bridge technique yields improvements in clinical outcome measures and a relatively high degree of patient satisfaction despite the fact that repair integrity is not maintained in many cases. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. The Technique of Changing the Drive Method of Micro Step Drive and Sensorless Drive for Hybrid Stepping Motor

    Science.gov (United States)

    Yoneda, Makoto; Dohmeki, Hideo

    The position control system with the advantage large torque, low vibration, and high resolution can be obtained by the constant current micro step drive applied to hybrid stepping motor. However loss is large, in order not to be concerned with load torque but to control current uniformly. As the one technique of a position control system in which high efficiency is realizable, the same sensorless control as a permanent magnet motor is effective. But, it was the purpose that the control method proposed until now controls speed. Then, this paper proposed changing the drive method of micro step drive and sensorless drive. The change of the drive method was verified from the simulation and the experiment. On no load, it was checked not producing change of a large speed at the time of a change by making electrical angle and carrying out zero reset of the integrator. On load, it was checked that a large speed change arose. The proposed system could change drive method by setting up the initial value of an integrator using the estimated result, without producing speed change. With this technique, the low loss position control system, which employed the advantage of the hybrid stepping motor, has been built.

  5. Biomechanical comparison of four double-row speed-bridging rotator cuff repair techniques with or without medial or lateral row enhancement.

    Science.gov (United States)

    Pauly, Stephan; Fiebig, David; Kieser, Bettina; Albrecht, Bjoern; Schill, Alexander; Scheibel, Markus

    2011-12-01

    Biomechanical comparison of four different Speed-Bridge configurations with or without medial or lateral row reinforcement. Reinforcement of the knotless Speed-Bridge double-row repair technique with additional medial mattress- or lateral single-stitches was hypothesized to improve biomechanical repair stability at time zero. Controlled laboratory study: In 36 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected and shoulders were randomized to four groups: (1) Speed-Bridge technique with single tendon perforation per anchor (STP); (2) Speed-Bridge technique with double tendon perforation per anchor (DTP); (3) Speed-Bridge technique with medial mattress-stitch reinforcement (MMS); (4) Speed-Bridge technique with lateral single-stitch reinforcement (LSS). All repairs were cyclically loaded from 10-60 N up to 10-200 N (20 N stepwise increase) using a material testing device. Forces at 3 and 5 mm gap formation, mode of failure and maximum load to failure were recorded. The MMS-technique with double tendon perforation showed significantly higher ultimate tensile strength (338.9 ± 90.0 N) than DTP (228.3 ± 99.9 N), LSS (188.9 ± 62.5 N) and STP-technique (122.2 ± 33.8 N). Furthermore, the MMS-technique provided increased maximal force resistance until 3 and 5 mm gap formation (3 mm: 77.8 ± 18.6 N; 5 mm: 113.3 ± 36.1 N) compared with LSS, DTP and STP (P row defect by tendon sawing first, then laterally. No anchor pullout occurred. Double tendon perforation per anchor and additional medial mattress stitches significantly enhance biomechanical construct stability at time zero in this ex vivo model when compared with the all-knotless Speed-Bridge rotator cuff repair.

  6. A Novel Technique for Rotor Bar Failure Detection in Single-Cage Induction Motor Using FEM and MATLAB/SIMULINK

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Taher

    2011-01-01

    Full Text Available In this article, a new fault detection technique is proposed for squirrel cage induction motor (SCIM based on detection of rotor bar failure. This type of fault detection is commonly carried out, while motor continues to work at a steady-state regime. Recently, several methods have been presented for rotor bar failure detection based on evaluation of the start-up transient current. The proposed method here is capable of fault detection immediately after bar breakage, where a three-phase SCIM is modelled in finite element method (FEM using Maxwell2D software. Broken rotor bars are then modelled by the corresponding outer rotor impedance obtained by GA, thereby presenting an analogue model extracted from FEM to be simulated in a flexible environment such as MATLAB/SIMULINK. To improve the failure recognition, the stator current signal was analysed using discrete wavelet transform (DWT.

  7. [Three years results of transvaginal cystocele repair with polypropylene mesh using a tension-free technique].

    Science.gov (United States)

    El Harrech, Y; Ameur, A; Janane, A; Moufide, K; Ghadouane, M; Abbar, M

    2010-01-01

    To evaluate the long term efficacy and safety of transvaginal implantation of a non-resorbable synthetic prosthesis (Gynemesh) for the treatment of cystocele using transvaginal free tension technique. Prospective study of patients that have been submitted to correction of cystocele between April 2004 and July 2007. A prolene mesh was cut to an appropriate size to cover the whole cystocele leaving two tabs on each side. The two tabs of the mesh were then placed in paravaginal spaces, tension free, without stitches. Mesh was used in 31 patients. All patients had a symptomatic cystocele >or= 2 according to Baden-Walker halfway classification. Patients were reviewed initially at 1 and 3 month and then every 6 months. The mean age of the patients was 58 years (range: 47-70 years). Mean parity was 5.8 (range 1-11), and mean weight was 75 kg (range 60-82Kg). All women were postmenopausal. The operation was combined with vaginal hysterectomy in 2 patients, Posterior colporraphy in 2 patients, Perineorrhaphy in 1 patient, Sacrospinous fixation in 2 patients, transobturator tape for stress urinary incontinence in 7 women. Average time of surgery was 23 minutes for cystocele. There were no major complications, such as trauma to the bladder, urethra, bowels, or large vessels in the patient group treated. There was no immediate postoperative complications (up to 7 days) recorded. No hematoma or infection was observed in the operative area. Mesh erosion was detected in one patient. It was treated by excision of the eroded part of the mesh. Mean follow-up was 36.4 months (18 to 52 months). Using our definition of success based on both anatomic and functional outcomes, the overall cure rate was 74.19% (asymptomatic with no or grade 1 cystocele). The improvement rate (asymptomatic with a grade 2 cystocele) was 19.35% and the overall failure rate (symptomatic or with a grade 3 or 4 cystocele) was only 6.4% (2 women). The interposition of a sub-vesical transversal tension

  8. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Excellent healing rates and patient satisfaction after arthroscopic repair of medium to large rotator cuff tears with a single-row technique augmented with bone marrow vents.

    Science.gov (United States)

    Dierckman, Brian D; Ni, Jake J; Karzel, Ronald P; Getelman, Mark H

    2018-01-01

    This study evaluated the repair integrity and patient clinical outcomes following arthroscopic rotator cuff repair of medium to large rotator cuff tears using a single-row technique consisting of medially based, triple-loaded anchors augmented with bone marrow vents in the rotator cuff footprint lateral to the repair. This is a retrospective study of 52 patients (53 shoulders) comprising 36 males and 16 females with a median age of 62 (range 44-82) with more than 24-month follow-up, tears between 2 and 4 cm in the anterior-posterior dimension and utilizing triple-loaded anchors. Mann-Whitney test compared Western Ontario Rotator Cuff (WORC) outcome scores between patients with healed and re-torn cuff repairs. Multivariate logistic regression analysed association of variables with healing status and WORC score. Cuff integrity was assessed on MRI, read by a musculoskeletal fellowship-trained radiologist. Magnetic resonance imaging (MRI) demonstrated an intact repair in 48 of 53 shoulders (91%). The overall median WORC score was 95.7 (range 27.6-100.0). A significant difference in WORC scores were seen between patients with healed repairs 96.7 (range 56.7-100.0) compared with a re-tear 64.6 (27.6-73.8), p rotator cuff tears using a triple-loaded single-row repair augmented with bone marrow vents resulted in a 91% healing rate by MRI and excellent patient reported clinical outcomes comparable to similar reported results in the literature. IV.

  10. Mini- or Less-open Sublay Operation (MILOS): A New Minimally Invasive Technique for the Extraperitoneal Mesh Repair of Incisional Hernias.

    Science.gov (United States)

    Reinpold, Wolfgang; Schröder, Michael; Berger, Cigdem; Nehls, Jennifer; Schröder, Alexander; Hukauf, Martin; Köckerling, Ferdinand; Bittner, Reinhard

    2018-01-16

    Improvement of ventral hernia repair. Despite the use of mesh and other recent improvements, the currently popular techniques of ventral hernia repair have specific disadvantages and risks. We developed the endoscopically assisted mini- or less-open sublay (MILOS) concept. The operation is performed transhernially via a small incision with light-holding laparoscopic instruments either under direct, or endoscopic visualization. An endoscopic light tube was developed to facilitate this approach (EndotorchTM Wolf Company). Each MILOS operation can be converted to standard total extraperitoneal gas endoscopy once an extraperitoneal space of at least 8 cm has been created. All MILOS operations were prospectively documented in the German Hernia registry with 1 year questionnaire follow-up. Propensity score matching of incisional hernia operations comparing the results of the MILOS operation with the laparoscopic intraperitoneal onlay mesh operation (IPOM) and open sublay repair from other German Hernia registry institutions was performed. Six hundred fifteen MILOS incisional hernia operations were included. Compared with laparoscopic IPOM incisional hernia operation, the MILOS repair is associated with significantly a fewer postoperative surgical complications (P advantages of open sublay and the laparoscopic IPOM repair.ClinicalTrials.gov Identifier NCT03133000.

  11. Can inhibitory and facilitatory kinesiotaping techniques affect motor neuron excitability? A randomized cross-over trial.

    Science.gov (United States)

    Yoosefinejad, Amin Kordi; Motealleh, Alireza; Abbasalipur, Shekoofeh; Shahroei, Mahan; Sobhani, Sobhan

    2017-04-01

    The aim of this study was to investigate the immediate effects of facilitatory and inhibitory kinesiotaping on motor neuron excitability. Randomized cross-over trial. Twenty healthy people received inhibitory and facilitatory kinesiotaping on two testing days. The H- and M-waves of the lateral gasterocnemius were recorded before and immediately after applying the two modes of taping. The Hmax/Mmax ratio (a measure of motor neuron excitability) was determined and analyzed. The mean Hmax/Mmax ratios were -0.013 (95% CI: -0.033 to 0.007) for inhibitory taping and 0.007 (95% CI: -0.013 to 0.027) for facilitatory taping. The mean difference between groups was -0.020 (95% CI: -0.048 to 0.008). The statistical model revealed no significant differences between the two interventions (P = 0.160). Furthermore, there were no within-group differences in Hmax/Mmax ratio for either group. Our findings did not disclose signs of immediate change in motor neuron excitability in the lateral gasterocnemius. Copyright © 2016. Published by Elsevier Ltd.

  12. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    Science.gov (United States)

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  13. Early- and Mid-term Results of the Chimney Technique in the Repair of Aortic Arch Pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Junjie; Jiao, Yuanyong, E-mail: wishlucky@163.com, E-mail: johemail@163.com; Zhang, Xiwei; Jiang, Jun; Yang, Hongyu; Ma, Hao [First Affiliated Hospital of Nanjing Medical University, Division of Vascular Surgery, Department of General Surgery (China)

    2016-11-15

    PurposeTo examine the safety, feasibility, and mid-term efficacy of the chimney technique for aortic arch pathologies.MethodsFrom February 2011 to December 2014, a total of 35 patients (30 men; mean age 54.3 ± 14.1 years) with aortic arch pathologies underwent thoracic endovascular aortic repair combined with chimney stents. The indication was a proximal landing zone <1.5 cm. Follow-up was performed at 3, 6, and 12 months and then yearly thereafter.ResultsA total of 36 chimney stents were deployed (innominate artery, n = 1; left common carotid artery, n = 9; right subclavian artery, n = 1; left subclavian artery, n = 25). The technical success rate was 94.3 % (33/35). Immediate type Ia endoleaks (ELIa) were observed in two patients (8.6 %, 2/35). Twenty-five patients were successfully followed-up for a median period of 29.3 months (range, 6–48 months). One patient died due to aortic dissection aneurysm rupture at 36 months (mortality rate of 4 %, 1/25). Three late ELIa were observed and no reinterventions were performed. The overall incidence of ELIa was 20 % (5/25). During follow-up, the patency rate for chimney stents was 92 % (23/25).ConclusionOur limited experience demonstrates that the chimney technique is a viable and relatively safe treatment for patients with challenging thoracic aortic pathologies at least in the mid-term follow-up period.

  14. Early- and Mid-term Results of the Chimney Technique in the Repair of Aortic Arch Pathologies

    International Nuclear Information System (INIS)

    Zou, Junjie; Jiao, Yuanyong; Zhang, Xiwei; Jiang, Jun; Yang, Hongyu; Ma, Hao

    2016-01-01

    PurposeTo examine the safety, feasibility, and mid-term efficacy of the chimney technique for aortic arch pathologies.MethodsFrom February 2011 to December 2014, a total of 35 patients (30 men; mean age 54.3 ± 14.1 years) with aortic arch pathologies underwent thoracic endovascular aortic repair combined with chimney stents. The indication was a proximal landing zone <1.5 cm. Follow-up was performed at 3, 6, and 12 months and then yearly thereafter.ResultsA total of 36 chimney stents were deployed (innominate artery, n = 1; left common carotid artery, n = 9; right subclavian artery, n = 1; left subclavian artery, n = 25). The technical success rate was 94.3 % (33/35). Immediate type Ia endoleaks (ELIa) were observed in two patients (8.6 %, 2/35). Twenty-five patients were successfully followed-up for a median period of 29.3 months (range, 6–48 months). One patient died due to aortic dissection aneurysm rupture at 36 months (mortality rate of 4 %, 1/25). Three late ELIa were observed and no reinterventions were performed. The overall incidence of ELIa was 20 % (5/25). During follow-up, the patency rate for chimney stents was 92 % (23/25).ConclusionOur limited experience demonstrates that the chimney technique is a viable and relatively safe treatment for patients with challenging thoracic aortic pathologies at least in the mid-term follow-up period.

  15. DNA repair

    International Nuclear Information System (INIS)

    Van Zeeland, A.A.

    1984-01-01

    In this chapter a series of DNA repair pathways are discussed which are available to the cell to cope with the problem of DNA damaged by chemical or physical agents. In the case of microorganisms our knowledge about the precise mechanism of each DNA repair pathway and the regulation of it has been improved considerably when mutants deficient in these repair mechanisms became available. In the case of mammalian cells in culture, until recently there were very little repair deficient mutants available, because in almost all mammalian cells in culture at least the diploid number of chromosomes is present. Therefore the frequency of repair deficient mutants in such populations is very low. Nevertheless because replica plating techniques are improving some mutants from Chinese hamsters ovary cells and L5178Y mouse lymphoma cells are now available. In the case of human cells, cultures obtained from patients with certain genetic diseases are available. A number of cells appear to be sensitive to some chemical or physical mutagens. These include cells from patients suffering from xeroderma pigmentosum, Ataxia telangiectasia, Fanconi's anemia, Cockayne's syndrome. However, only in the case of xeroderma pigmentosum cells, has the sensitivity to ultraviolet light been clearly correlated with a deficiency in excision repair of pyrimidine dimers. Furthermore the work with strains obtained from biopsies from man is difficult because these cells generally have low cloning efficiencies and also have a limited lifespan in vitro. It is therefore very important that more repair deficient mutants will become available from established cell lines from human or animal origin

  16. Development of a Novel Motor Imagery Control Technique and Application in a Gaming Environment

    OpenAIRE

    Li, Ting; Zhang, Jinhua; Xue, Tao; Wang, Baozeng

    2017-01-01

    We present a methodology for a hybrid brain-computer interface (BCI) system, with the recognition of motor imagery (MI) based on EEG and blink EOG signals. We tested the BCI system in a 3D Tetris and an analogous 2D game playing environment. To enhance player’s BCI control ability, the study focused on feature extraction from EEG and control strategy supporting Game-BCI system operation. We compared the numerical differences between spatial features extracted with common spatial pattern (CSP)...

  17. Comparison of Broström technique, suture anchor repair, and tape augmentation for reconstruction of the anterior talofibular ligament.

    Science.gov (United States)

    Schuh, R; Benca, E; Willegger, M; Hirtler, L; Zandieh, S; Holinka, J; Windhager, R

    2016-04-01

    Recently, tape augmentation for Broström repair has been introduced in order to improve the primary stability of the reconstructed anterior talofibular ligament (ATFL). The biomechanical effect of tape augmentation suture anchor (SA) repair is not known yet. The aim of the present study was to compare construct stability of the traditional Broström (TB) repair compared with a stand alone SA repair (SutureTak, Arthrex) and SA repair combined with tape augmentation (InternalBrace, Arthrex) internal brace (IB) of the ATFL. Eighteen fresh-frozen human anatomic lower leg specimens were randomly assigned to three different groups: TB group, SA group, and IB augmentation group. In vivo torsion conditions in ankle sprain were carried out quasi-statically (0.5°/s). Torque (Nm) required to resist as well as the rotary displacement (°) of the load frame was recorded. Intergroup differences for age, bone mineral density (BMD), angle at failure, and torque at failure were analysed using ANOVA. In the TB group, ATFL reconstruction failed at an angle of 24.1°, in the SA group failure occurred at 35.5°, and in the IB group it failed at 46.9° (p = 0.02). Torque at failure reached 5.7 Nm for the TB repair, 8.0 Nm for the SA repair, and 11.2 Nm for the IB group (p = 0.04). There was no correlation between angle at ATFL failure, torque at failure, and BMD for the SA or IB groups. The present biomechanical study reveals statistically superior performance in terms of angle at failure as well as failure torque for the IB group compared to the other reconstruction methods. BMD did not influence the construct stability in the SA repair groups.

  18. "Digit anatomy": a new technique for learning anatomy using motor memory.

    Science.gov (United States)

    Oh, Chang-Seok; Won, Hyung-Sun; Kim, Kyong-Jee; Jang, Dong-Su

    2011-01-01

    Gestural motions of the hands and fingers are powerful tools for expressing meanings and concepts, and the nervous system has the capacity to retain multiple long-term motor memories, especially including movements of the hands. We developed many sets of successive movements of both hands, referred to as "digit anatomy," and made students practice the movements which express (1) the aortic arch, subclavian, and thoracoacromial arteries and their branches, (2) the celiac trunk, superior mesenteric artery and their branches, and formation of the portal vein, (3) the heart and the coronary arteries, and (4) the brachial, lumbar, and sacral plexuses. A feedback survey showed that digit anatomy was helpful for the students not only in memorizing anatomical structures but also in understanding their functions. Out of 40 students, 34 of them who learned anatomy with the help of digit anatomy were "very satisfied" or "generally satisfied" with this new teaching method. Digit anatomy that was used to express the aortic arch, subclavian, and thoracoacromial arteries and their branches was more helpful than those representing other structures. Although the movements of digit anatomy are expected to be remembered longer than the exact meaning of each movement, invoking the motor memory of the movement may help to make relearning of the same information easier and faster in the future. Copyright © 2011 American Association of Anatomists.

  19. Nonlinear control techniques of a controllable rectifier/inverter-motor drive system with a small dc-link capacitor

    International Nuclear Information System (INIS)

    Liutanakul, Pisit; Pierfederici, Serge; Meibody-Tabar, Farid

    2008-01-01

    The necessity of the converters compactness in many applications imposes the reduction of their different components size when it is possible. In this paper, a control method allowing the use of a small size dc-link capacitor for the cascade of voltage controlled-rectifier/inverter-motor drive system is proposed. This is achieved by adding the power balance equation in the system's model and the application of an exact input/output feedback linearization technique in a way that the rectifier controller compensates any sudden change in the inverter load, which is here an induction motor. Since the exact input/output feedback linearization technique is sensitive to the uncertainties over system parameters, a robust control strategy based on sliding mode controller is proposed. By this approach, the dc-link voltage becomes almost insensitive to the load variations. As a result, the level of the dc-link voltage could be stabilized with a small size dc-link capacitor. Without any considerations of the RMS current stress on this dc-link capacitor, a calculation method of a minimum value of this capacitor based on its storage energy is proposed. All the investigations are shown by computer simulations and the performance of controlled system is verified by experimentation results

  20. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Directory of Open Access Journals (Sweden)

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  1. Design and Simulation of Control Technique for Permanent Magnet Synchronous Motor Using Space Vector Pulse Width Modulation

    Science.gov (United States)

    Khan, Mansoor; Yong, Wang; Mustafa, Ehtasham

    2017-07-01

    After the rapid advancement in the field of power electronics devices and drives for last few decades, there are different kinds of Pulse Width Modulation techniques which have been brought to the market. The applications ranging from industrial appliances to military equipment including the home appliances. The vey common application for the PWM is three phase voltage source inverter, which is used to convert DC to AC in the homes to supply the power to the house in case electricity failure, usually named as Un-interrupted Power Supply. In this paper Space Vector Pulse Width Modulation techniques is discussed and analysed under the control technique named as Field Oriented Control. The working and implementation of this technique has been studied by implementing on the three phase bridge inverter. The technique is used to control the Permanente Magnet Synchronous Motor. The drive system is successfully implemented in MATLAB/Simulink using the mathematical equation and algorithm to achieve the satisfactory results. PI type of controller is used to tuned ers of the motothe parametr i.e. torque and current.

  2. Arthroscopic repair of anterosuperior rotator cuff tears: in-continuity technique vs. disruption of subscapularis-supraspinatus tear margin: comparison of clinical outcomes and structural integrity between the two techniques.

    Science.gov (United States)

    Kim, Sung-Jae; Jung, Min; Lee, Jae-Hoo; Kim, Chul; Chun, Yong-Min

    2014-12-17

    The purpose of this study was to compare the clinical outcomes and structural integrity after two techniques of arthroscopic anterosuperior rotator cuff repair: in continuity and disruption of the tear margin. This study included fifty-nine patients who underwent arthroscopic repair of an anterosuperior rotator cuff tear that was done either by disrupting the margin between the subscapularis and supraspinatus tears (Group A) or by performing the repair in continuity without disrupting the margin (Group B). Clinical outcomes were assessed on the basis of a visual analog scale (VAS) pain score, subjective shoulder value (SSV), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and active range of motion of the shoulder. Subscapularis strength was assessed with use of the modified belly-press test. Magnetic resonance arthrography (MRA) or computed tomographic arthrography (CTA) was performed at six months after surgery to assess the structural integrity of the repair. At the two-year follow-up evaluation, VAS pain scores, SSVs, ASES scores, UCLA shoulder scores, subscapularis strength, and active range of motion improved significantly in both groups compared with preoperatively (p tears of the rotator cuff, the technique of in-continuity repair did not produce better clinical outcomes or structural integrity than the technique involving disruption of the tear margin. If the muscle in an anterosuperior rotator cuff tear is of good quality, it does not appear to matter whether the tear margin between the subscapularis and supraspinatus is preserved or disrupted. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Development of a Novel Motor Imagery Control Technique and Application in a Gaming Environment.

    Science.gov (United States)

    Li, Ting; Zhang, Jinhua; Xue, Tao; Wang, Baozeng

    2017-01-01

    We present a methodology for a hybrid brain-computer interface (BCI) system, with the recognition of motor imagery (MI) based on EEG and blink EOG signals. We tested the BCI system in a 3D Tetris and an analogous 2D game playing environment. To enhance player's BCI control ability, the study focused on feature extraction from EEG and control strategy supporting Game-BCI system operation. We compared the numerical differences between spatial features extracted with common spatial pattern (CSP) and the proposed multifeature extraction. To demonstrate the effectiveness of 3D game environment at enhancing player's event-related desynchronization (ERD) and event-related synchronization (ERS) production ability, we set the 2D Screen Game as the comparison experiment. According to a series of statistical results, the group performing MI in the 3D Tetris environment showed more significant improvements in generating MI-associated ERD/ERS. Analysis results of game-score indicated that the players' scores presented an obvious uptrend in 3D Tetris environment but did not show an obvious downward trend in 2D Screen Game. It suggested that the immersive and rich-control environment for MI would improve the associated mental imagery and enhance MI-based BCI skills.

  4. Development of a Novel Motor Imagery Control Technique and Application in a Gaming Environment

    Directory of Open Access Journals (Sweden)

    Ting Li

    2017-01-01

    Full Text Available We present a methodology for a hybrid brain-computer interface (BCI system, with the recognition of motor imagery (MI based on EEG and blink EOG signals. We tested the BCI system in a 3D Tetris and an analogous 2D game playing environment. To enhance player’s BCI control ability, the study focused on feature extraction from EEG and control strategy supporting Game-BCI system operation. We compared the numerical differences between spatial features extracted with common spatial pattern (CSP and the proposed multifeature extraction. To demonstrate the effectiveness of 3D game environment at enhancing player’s event-related desynchronization (ERD and event-related synchronization (ERS production ability, we set the 2D Screen Game as the comparison experiment. According to a series of statistical results, the group performing MI in the 3D Tetris environment showed more significant improvements in generating MI-associated ERD/ERS. Analysis results of game-score indicated that the players’ scores presented an obvious uptrend in 3D Tetris environment but did not show an obvious downward trend in 2D Screen Game. It suggested that the immersive and rich-control environment for MI would improve the associated mental imagery and enhance MI-based BCI skills.

  5. Virtual reality techniques in older adults: exposure therapy, memory training, and training of motor balance

    NARCIS (Netherlands)

    Meyerbröker, K.; Emmelkamp, P.M.G.; Pachana, N.A.; Laidlaw, K.

    2014-01-01

    We reviewed the literature on virtual reality techniques in older adults. Although treatment of specific phobias in older adults by virtual reality exposure therapy (VRET) is feasible and might be effective, this has yet not been evaluated in randomized controlled trials. The few controlled studies

  6. Handbook of adhesive bonded structural repair

    CERN Document Server

    Wegman, Raymond F

    1992-01-01

    Provides repair methods for adhesive bonded and composite structures; identifies suitable materials and equipment for repairs; describes damage evaluation criteria and techniques, and methods of inspection before and after repair.

  7. Short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx: Description of the injury and a technique for repair.

    Science.gov (United States)

    Wright, I M; Minshall, G J

    2018-01-01

    Chip fractures of the dorsoproximal articular margin of the proximal phalanx are common injuries in racehorses. Large fractures can extend distal to the joint capsule insertion and have been described as dorsal frontal fractures. To report the location and morphology of short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx and describe a technique for repair under arthroscopic and radiographic guidance. Single centre retrospective case study. Case records of horses with frontal plane fractures restricted to the dorsoproximal epiphysis and metaphysis of the proximal phalanx referred to Newmarket Equine Hospital were retrieved, images reviewed and lesion morphology described. A technique for repair and the results obtained are reported. A total of 22 fractures in 21 horses commencing at the proximal articular surface exited the dorsal cortex of the proximal phalanx distal to the metacarpophalangeal/metatarsophalangeal joint capsule in 17 hind- and five forelimbs. All were in Thoroughbred racehorses. In 16 cases these were acute racing or training injuries; 20 fractures were medial, one lateral and one was midline. All were repaired with a single lag screw using arthroscopic and radiographically determined landmarks. A total of 16 horses raced after surgery with performance data similar to their preinjury levels. The study demonstrates substantial morphological similarities between individual lesions supporting a common pathophysiology, but does not identify precise causation. There are no cases managed differently that might permit assessment of the comparative efficacy of the treatment described. Short frontal plane fractures involving the dorsoproximal margin of the proximal phalanx that exit the bone distal to the metacarpophalangeal/metatarsophalangeal joint capsule have substantial morphological similarities, are amenable to minimally invasive repair and carry a good prognosis for return to training and racing.

  8. Bi Input-extended Kalman filter based estimation technique for speed-sensorless control of induction motors

    International Nuclear Information System (INIS)

    Barut, Murat

    2010-01-01

    This study offers a novel extended Kalman filter (EKF) based estimation technique for the solution of the on-line estimation problem related to uncertainties in the stator and rotor resistances inherent to the speed-sensorless high efficiency control of induction motors (IMs) in the wide speed range as well as extending the limited number of states and parameter estimations possible with a conventional single EKF algorithm. For this aim, the introduced estimation technique in this work utilizes a single EKF algorithm with the consecutive execution of two inputs derived from the two individual extended IM models based on the stator resistance and rotor resistance estimation, differently from the other approaches in past studies, which require two separate EKF algorithms operating in a switching or braided manner; thus, it has superiority over the previous EKF schemes in this regard. The proposed EKF based estimation technique performing the on-line estimations of the stator currents, the rotor flux, the rotor angular velocity, and the load torque involving the viscous friction term together with the rotor and stator resistance is also used in the combination with the speed-sensorless direct vector control of IM and tested with simulations under the challenging 12 scenarios generated instantaneously via step and/or linear variations of the velocity reference, the load torque, the stator resistance, and the rotor resistance in the range of high and zero speed, assuming that the measured stator phase currents and voltages are available. Even under those variations, the performance of the speed-sensorless direct vector control system established on the novel EKF based estimation technique is observed to be quite good.

  9. Bi Input-extended Kalman filter based estimation technique for speed-sensorless control of induction motors

    Energy Technology Data Exchange (ETDEWEB)

    Barut, Murat, E-mail: muratbarut27@yahoo.co [Nigde University, Department of Electrical and Electronics Engineering, 51245 Nigde (Turkey)

    2010-10-15

    This study offers a novel extended Kalman filter (EKF) based estimation technique for the solution of the on-line estimation problem related to uncertainties in the stator and rotor resistances inherent to the speed-sensorless high efficiency control of induction motors (IMs) in the wide speed range as well as extending the limited number of states and parameter estimations possible with a conventional single EKF algorithm. For this aim, the introduced estimation technique in this work utilizes a single EKF algorithm with the consecutive execution of two inputs derived from the two individual extended IM models based on the stator resistance and rotor resistance estimation, differently from the other approaches in past studies, which require two separate EKF algorithms operating in a switching or braided manner; thus, it has superiority over the previous EKF schemes in this regard. The proposed EKF based estimation technique performing the on-line estimations of the stator currents, the rotor flux, the rotor angular velocity, and the load torque involving the viscous friction term together with the rotor and stator resistance is also used in the combination with the speed-sensorless direct vector control of IM and tested with simulations under the challenging 12 scenarios generated instantaneously via step and/or linear variations of the velocity reference, the load torque, the stator resistance, and the rotor resistance in the range of high and zero speed, assuming that the measured stator phase currents and voltages are available. Even under those variations, the performance of the speed-sensorless direct vector control system established on the novel EKF based estimation technique is observed to be quite good.

  10. Extensive and equivalent repair in both radiation-resistant and radiation-sensitive E. coli determined by a DNA-unwinding technique

    International Nuclear Information System (INIS)

    Ahnstroem, G.; George, A.M.; Cramp, W.A.

    1978-01-01

    The extent of strand breakage and repair in irradiated E. coli B/r and Bsub(s-l) was studied using a DNA-unwinding technique in denaturing conditions of weak alkali. Although these two strains showed widely different response to the lethal effects of ionizing radiation, they both had an equal capacity to repair radiation-induced breaks in DNA. Oxygen enhancement ratios for the killing of B/r and Bsub(s-l) were respectively 4 and 2; but after repair in non-nutrient or nutrient post-irradiation conditions, the oxygen enhancement values for the residual strand breaks were always the same for the two strains. The equal abilities of E.coli B/r and E.coli Bsub(s-l) to remove the strand breaks measured by this weak-alkali technqiue has led to the suggestion that some other type of damage to either DNA or another macromolecule may play a major role in determining whether or not the cells survive to proliferate. (author)

  11. Extensive and equivalent repair in both radiation-resistant and radiation-sensitive E. coli determined by a DNA-unwinding technique

    Energy Technology Data Exchange (ETDEWEB)

    Ahnstroem, G [Stockholm Univ. (Sweden); George, A M; Cramp, W A

    1978-10-01

    The extent of strand breakage and repair in irradiated E. coli B/r and Bsub(s-l) was studied using a DNA-unwinding technique in denaturing conditions of weak alkali. Although these two strains showed widely different response to the lethal effects of ionizing radiation, they both had an equal capacity to repair radiation-induced breaks in DNA. Oxygen enhancement ratios for the killing of B/r and Bsub(s-l) were respectively 4 and 2; but after repair in non-nutrient or nutrient post-irradiation conditions, the oxygen enhancement values for the residual strand breaks were always the same for the two strains. The equal abilities of E.coli B/r and E.coli Bsub(s-l) to remove the strand breaks measured by this weak-alkali technqiue has led to the suggestion that some other type of damage to either DNA or another macromolecule may play a major role in determining whether or not the cells survive to proliferate.

  12. Orbital stability analysis in biomechanics: a systematic review of a nonlinear technique to detect instability of motor tasks.

    Science.gov (United States)

    Riva, F; Bisi, M C; Stagni, R

    2013-01-01

    Falls represent a heavy economic and clinical burden on society. The identification of individual chronic characteristics associated with falling is of fundamental importance for the clinicians; in particular, the stability of daily motor tasks is one of the main factors that the clinicians look for during assessment procedures. Various methods for the assessment of stability in human movement are present in literature, and methods coming from stability analysis of nonlinear dynamic systems applied to biomechanics recently showed promise. One of these techniques is orbital stability analysis via Floquet multipliers. This method allows to measure orbital stability of periodic nonlinear dynamic systems and it seems a promising approach for the definition of a reliable motor stability index, taking into account for the whole task cycle dynamics. Despite the premises, its use in the assessment of fall risk has been deemed controversial. The aim of this systematic review was therefore to provide a critical evaluation of the literature on the topic of applications of orbital stability analysis in biomechanics, with particular focus to methodologic aspects. Four electronic databases have been searched for articles relative to the topic; 23 articles were selected for review. Quality of the studies present in literature has been assessed with a customised quality assessment tool. Overall quality of the literature in the field was found to be high. The most critical aspect was found to be the lack of uniformity in the implementation of the analysis to biomechanical time series, particularly in the choice of state space and number of cycles to include in the analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  14. Relations between Anthropometric Characteristics and Motor Abilities of 14 – 15U Female Swimmers on 50m Result for each Technique

    Directory of Open Access Journals (Sweden)

    Goran Dimitrić

    2016-10-01

    Full Text Available In aim of correlation between antropometric characteristics, motor abilities and results of swimming 50m in all swimming techniques, a group of 22 swimmers (girls of Serbian national team, aged 14-15, underwent some anthropometric measurements as well as some motor abilities. Observed longitudinal dimensions were: body height, body mass, arm span and torax circumference and observed motor abilities were: body strength (arms, legs, stomach and flexibility (trunk and arms. Regression analisys showed that arm span corellated with 50m butterfly and free style score as well as strenght of body and legs corellated with 50m backstroke and free style score. Other measures didn΄t corelatted significantly on this sample. Study results confirms importance of arm span and some segments of body strenhgt of swimmers (girls for successful swimm on 50m in butterfly, backstroke and freestyle techniques in the age 14-15 years.

  15. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  16. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  17. Considerations Regarding the Opportunity of Using Psychological Techniques to Stimulate Solutions Characterized by Novelty and Inventive Step in TISR Transformers and Electric Motors with Shorted Moving Coil

    Directory of Open Access Journals (Sweden)

    Georgescu Daniel Ștefan

    2014-09-01

    Full Text Available This paper presents the appreciations and contributions regarding the use of psychological techniques to stimulate technical creativity with special reference to consonant association technique and inversion technique. The study is performed in the field of TISR transformers and electric motors with limited movement, starting from the analogy between a transformer and an electric motor with shorted coil. It approached a particular aspect of inversion technique in relation with the transformation of negative effects and results of laws, phenomena and processes into useful applications. The matter reffered to is related to the question: ,,why disadvantages and no advantages ?". At the end of the paper are presented and discussed some experimental models produced and studied by the authors in the Research Laboratory of Machines, Equipment and Drives at the University of Suceava and are exposed conclusions drawn from the experimental study and directions for future research.

  18. Clinical experience with arthroscopically-assisted repair of peripheral triangular fibrocartilage complex tears in adolescents--technique and results.

    Science.gov (United States)

    Farr, Sebastian; Zechmann, Ulrike; Ganger, Rudolf; Girsch, Werner

    2015-08-01

    The purpose of this study was to report our preliminary results after arthroscopically-assisted repair of peripheral triangular fibrocartilage complex (TFCC) tears in adolescent patients. All children and adolescents who underwent arthroscopically-assisted repair of a Palmer 1B tear were identified and prospectively evaluated after a mean follow-up of 1.3 years. The postoperative assessment included documentation of clinical parameters, pain score (visual analogue scale, VAS), grip strength and completion of validated outcome scores (Modified Mayo Wrist Score, MMWS; Disabilities of the Arm, Shoulder and Hand Inventory, DASH). A total of 12 patients (four males, eight females) with a mean age of 16.3 years at the time of surgery were evaluated. The mean VAS decreased significantly from 7.0 to 1.7 after the procedure. We observed a significant increase of the MMWS after surgery; however, MMWS was still significantly lower at final follow-up when compared to the contralateral side. A mean postoperative DASH score of 16 indicated an excellent outcome after the procedure. DASH Sports and Work Modules showed fair and good overall outcomes in the short-term, respectively. Grip strength averaged 86 % of the contralateral side at final follow-up, with no significant difference being found between both sides. Arthroscopically-assisted repair of peripheral TFCC tears in adolescents provided predictable pain relief and markedly improved functional outcome scores. Concomitant pathologies may have to be addressed at the same time to eventually achieve a satisfactory outcome. Sports participation, however, may be compromised in the short-term and should therefore be resumed six months postoperatively.

  19. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  20. Clinical implications of hypothermic ventricular fibrillation versus beating-heart technique during cardiopulmonary bypass for pulmonary valve replacement in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Lee, Ji-Hyun; Lee, Ji-Eun; Shin, Jungho; Song, In-Kyung; Kim, Hee-Soo; Kim, Chong-Sung; Kim, Woong-Han; Kim, Jin-Tae

    2017-09-01

    This study aimed to compare the effects of hypothermic ventricular fibrillation and beating-heart techniques during cardiopulmonary bypass (CPB) on postoperative outcomes after simple pulmonary valve replacement in patients with repaired tetralogy of Fallot (TOF). We retrospectively reviewed the data of 47 patients with repaired tetralogy of Fallot at a single institution, who received pulmonary valve replacement under the ventricular fibrillation or beating-heart technique without cardioplegic cardiac arrest during CPB between January 2005 and April 2015. The patients were divided into fibrillation (n = 32) and beating-heart (n = 15) groups. On comparing these groups, the fibrillation group had a larger sinotubular junction (27.1 ± 4.6 vs 22.1 ± 2.4 mm), had a longer operation duration (396 ± 108 vs 345 ± 57 min), required more postoperative transfusions (2.1 ± 2.6 vs 5.0 ± 6.3 units) and had a higher vasoactive-inotropic score at intensive care unit admission (8.0 vs 10, all P tetralogy of Fallot. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Application of computer-aided three-dimensional skull model with rapid prototyping technique in repair of zygomatico-orbito-maxillary complex fracture.

    Science.gov (United States)

    Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu

    2009-06-01

    With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.

  2. Speed control with torque ripple reduction of switched reluctance motor by Hybrid Many Optimizing Liaison Gravitational Search technique

    Directory of Open Access Journals (Sweden)

    Nutan Saha

    2017-06-01

    Full Text Available This paper presents a control scheme for simultaneous control of the speed of Switched Reluctance Motor (SRM and minimizing the torque ripple employing Hybrid Many Optimizing Liaison Gravitational Search Algorithm (Hybrid MOLGSA technique. The control mechanism includes two controlling loops, the outer loop is governed for speed control and a current controller for the inner loop, intelligent selection of turn on and turn off angle for a 60 KW, 3-phase 6/8 SRM. It is noticed that the torque ripple coefficient, ISE of speed & current are reduced by 12.81%, 38.60%, 16.74% respectively by Hybrid MOLGSA algorithm compared to Gravitational Search Algorithm (GSA algorithm. It is also observed that the settling times for the controller using the parameter values for obtaining best values of torque ripple, Integral square error of speed and current are reduced by 51.25%, 58.04% and 59.375% by proposed Hybrid MOLGSA algorithm compared to the GSA algorithm.

  3. Development of a liquid-holding technique for the study of DNA-repair in human diploid fibroblasts

    International Nuclear Information System (INIS)

    Simons, J.W.I.M.

    1979-01-01

    Liquid-holding conditions can be obtained for human diploid skin fibro-blasts by keeping confluent cultures stationary over periods of 7 days or longer by means of conditioned medium. Under this condition recovery of radiation damage induced by ultraviolet light or X-rays is observed as an increase in cloning efficiency. The amount of recovery when expressed in a dose-modifying-factor appears higher than in bacteria and yeast. The repair-deficient human cell strains XP25Ro and XP7Be (xeroderma pigmentosum from complementation groups A and D respectively) exhibit less but still discernible recovery after UV-irradiation and the same was observed for AT5Bi (ataxia telangiectasia) after X-irradiation. Experiments on mutation induction indicated that the repair which takes place during liquid holding of UV-irradiated XP7Be cells reduces the mutant frequency considerably while after liquid holding of UV-irradiated wild-type cells the same or lower mutant frequencies were found for the lower exposures and the same or higher mutant frequencies for the higher exposures. (Auth.)

  4. The combined use of scanning vibrating electrode technique and micro-potentiometry to assess the self-repair processes in defects on 'smart' coatings applied to galvanized steel

    International Nuclear Information System (INIS)

    Taryba, M.; Lamaka, S.V.; Snihirova, D.; Ferreira, M.G.S.; Montemor, M.F.; Wijting, W.K.; Toews, S.; Grundmeier, G.

    2011-01-01

    Research highlights: → Weldable primers were modified with submicron containers loaded with corrosion inhibitors. → SVET and micro-potentiometry were used to study the corrosion inhibition ability. → Submicron containers do not damage the barrier properties of model primers. → Artificial defects of 50μm x 50 μm in a coating can be easily analyzed by SVET and SIET. → Inhibiting dissolution of sacrificial Zn may result in detrimental dissolution of Fe. - Abstract: Model weldable primer coatings for galvanized steel were modified with submicron containers loaded with corrosion inhibitors. This procedure aims at introducing a new functionality in the thin coatings self-repair ability. The assessment of this property demands new protocols and new approaches, combining conventional electrochemical methods with electrochemical and analytical techniques of micrometer spatial resolution. Thus, in this work model defects were created in the coatings by using a focused ion beam (FIB). The coated samples, containing the model defects, were immersed in a NaCl 0.05 M solution and the corrosion inhibition ability was studied using the scanning vibrating electrode technique (SVET) and the scanning ion-selective electrode technique (SIET). SVET-SIET measurements were performed quasi-simultaneously. Qualitative chemical analysis was performed by SEM combined with EDS. Complementary studies were carried out by electrochemical impedance spectroscopy (EIS) to assess the effect of the containers filled with corrosion inhibitors on the barrier properties of the coatings. The electrochemical results highlight the importance of the combined use of integral and localized electrochemical techniques to extract information for a better understanding of the corrosion processes and corresponding repair of active microscopic defects formed on thin coatings containing inhibitor filled containers.

  5. DNA repair

    International Nuclear Information System (INIS)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals

  6. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2015-01-01

    Objective: Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. Methods: The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). Results: In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15th day and in 66.7% on the 30th day, making the biological tissue stronger and more resistant (p=0.095). Conclusion: This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques

  7. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION.

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2012-01-01

    Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15(th) day and in 66.7% on the 30(th) day, making the biological tissue stronger and more resistant (p=0.095). This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques applied.

  8. Some areas of reliability technique which have been neglected to some extent - maintainability - human reliability - mechanical reliability - repairable systems

    International Nuclear Information System (INIS)

    Akersten, P.A.

    1985-01-01

    The present thesis consists of four papers, three of which are of a expositary nature and one more theoretical. The first two papers have a natural coupling to the man-machine interface. The first paper is devoted to the concept of maintainability and the role of man as maintenance technician. The second paper discusses aspects of human reliability, mainly studying man as operator. However, maintenance tasks can be studied in the same manner. The third paper concerns reliability prediction for mechanical components. This is an area of vital importance for the reliability practitioner, who needs realistic and easy-to-use mathematical models for different failure modes. The fourth paper discusses mathematical models for repairable systems, especially the problem of testing whether a constant event intensity model is adequate or not. (author)

  9. Surfactant-induced skin irritation and skin repair. Evaluation of the acute human irritation model by noninvasive techniques.

    Science.gov (United States)

    Wilhelm, K P; Freitag, G; Wolff, H H

    1994-06-01

    Although the induction of irritant dermatitis by surfactants has been extensively studied in recent years, our understanding of the repair phase of irritant dermatitis is limited. We investigated qualitative and quantitative differences in surfactant-induced irritant skin reactions from short-term exposure to three structurally different surfactants. Sodium lauryl sulfate (SLS), dodecyl trimethyl ammonium bromide (DTAB), and potassium soap were the model irritants. Surfactant solutions (0.5%) were applied for 24 hours to the volar aspect of the forearm of 11 volunteers. Irritant reactions were assessed until complete healing was indicated by visual assessment and by various aspects of skin function, that is, transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum that is, transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum corneum hydration (electrical capacitance). SLS and DTAB induced similar degrees of erythema, whereas SLS induced significantly higher TEWL increase. Although both erythema and TEWL were highest 1 hour after exposure to surfactants, skin dryness was a symptom with delayed onset, justifying the long observation period in this study. Minimum hydration values were measured as late as 7 days after surfactant exposure. Dryness was significantly more pronounced in areas exposed to SLS than in areas exposed to DTAB. Complete repair of the irritant reaction induced by either SLS or DTAB was achieved 17 days after surfactant exposure. Stratum corneum hydration was the last feature to return to baseline values. Potassium soap did not significantly influence any skin function. We emphasize the importance of extended periods needed before a patient with irritant contact dermatitis can be reexposed to irritant substances. The evaluation of the irritation potential of diverse surfactants depended significantly on the feature (erythema vs hydration and TEWL) measured.

  10. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  11. Comparison of Direct Pars Repair Techniques of Spondylolysis in Pediatric and Adolescent Patients: Pars Compression Screw Versus Pedicle Screw-Rod-Hook.

    Science.gov (United States)

    Karatas, Ali F; Dede, Ozgur; Atanda, Alfred A; Holmes, Larry; Rogers, Kenneth; Gabos, Peter; Shah, Suken A

    2016-08-01

    Retrospective clinical cohort study. To compare the clinical and radiographic outcomes of patients who were treated with intrasegmental pars fixation by either laminar compression screw (LS) or a pedicle screw, rod, and laminar hook (PSRH) construct. Spondylolysis is a nonunion defect of the pars interarticularis. In symptomatic spondylolysis, direct repair of the pars interarticularis defect can preserve motion and prevent abnormal stresses at the adjacent levels. Sixteen patients who failed nonoperative treatment and underwent direct pars repair by using LS (n=9) or PSRH (n=7) constructs were included in the study. Clinical outcome was assessed by using the MacNab criteria. Radiologic fusion and complications were evaluated using plain radiographs or computed tomography images and patient charts. The healing rate was 100% after 6 months. The healing time was similar in both the groups: LS, 6.5 months; PSRH, 6.2 months. Patients with PSRH (5.9 mo) were more likely to return to sports earlier relative to patients with LS (7.7 mo). There were no complications in the LS group; in the PSRH group, 1 patient had mild sensory deficit and 2 had superficial wound infections. The MacNab criteria for pain assessment showed an excellent or good outcome in 8 of 9 patients in LS group and 6 of 7 patients in PSRH group. Relative to LS patients, there was a significant increase in surgical time and estimated blood loss among PSRH patients. Either of the mentioned 2 techniques appears to produce acceptable results. Biplanar fluoroscopy and navigation systems could minimize the risk of screw misplacement with LS construct. Familiarity with the various fixation techniques will allow the surgeon to select the most appropriate surgical technique.

  12. Transvaginal repair of genital prolapse: preliminary results of a new tension-free vaginal mesh (Prolift technique)--a case series multicentric study.

    Science.gov (United States)

    Fatton, B; Amblard, J; Debodinance, P; Cosson, M; Jacquetin, B

    2007-07-01

    Our goal was to report the preliminary results of a transvaginal mesh repair of genital prolapse using the Prolift system. This retrospective multicentric study includes 110 patients. All patients had a stage 3 (at the hymen) or stage 4 (beyond the hymen) prolapse. Total mesh was used in 59 patients (53.6%), an isolated anterior mesh in 22 patients (20%) and an isolated posterior mesh in 29 patients (26.4%). We report one bladder injury sutured at surgery and two haematomas requiring secondary surgical management. At 3 months, 106 patients were available for follow-up. Mesh exposure occurred in five patients (4.7%), two of them requiring a surgical management. Granuloma without exposure occurred in three patients (2.8%). Failure rate (recurrent prolapse even asymptomatic or low grade symptomatic prolapse) was 4.7%. According to the perioperative and immediate post-operative results, Prolift repair seems to be a safe technique to correct pelvic organ prolapse. Anatomical and functional results must be assessed with a long-term follow-up to confirm the effectiveness and safety of the procedure.

  13. Refinement of Foam Backfill Technology for Expedient Airfield Damage Repair; Phase 2: Development of Prototype Foam Dispensing Equipment and Improved Tactics, Techniques and Procedures

    Science.gov (United States)

    2017-12-01

    ER D C TR -1 7- 14 U.S. Air Force Rapid Airfield Damage Repair Modernization Program Refinement of Foam Backfill Technology for...Backfill Technology for Expedient Airfield Damage Repair Phase II: Development of Prototype Foam Dispensing Equipment and Improved Tactics...procedures (TTPs) for rapid airfield damage repair (RADR) using foam backfill technology . Three different prototype foam dispensing systems were

  14. [Fabrication of 3-dimensional skull model with rapid prototyping technique and its primary application in repairing one case of cranio-maxillo-facial trauma].

    Science.gov (United States)

    Xia, Delin; Gui, Lai; Zhang, Zhiyong; Lu, Changsheng; Niu, Feng; Jin, Ji; Liu, Xiaoqing

    2005-10-01

    To investigate the methods of establishing 3-dimensional skull model using electron beam CT (EBCT) data rapid prototyping technique, and to discuss its application in repairing cranio-maxillo-facial trauma. The data were obtained by EBCT continuous volumetric scanning with 1.0 mm slice at thickness. The data were transferred to work-station for 3-dimensional surface reconstruction by computer-aided design software and the images were saved as STL file. The data can be used to control a laser rapid-prototyping device (AFS-320QZ) to construct geometric model. The material for the model construction is a kind of laser-sensitive resin power, which will become a mass when scanned by laser beam. The design and simulation of operation can be done on the model. The image data were transferred to the device slice by slice. Thus a geometric model is constructed according to the image data by repeating this process. Preoperative analysis, surgery simulation and implant of bone defect could be done on this computer-aided manufactured 3D model. One case of cranio-maxillo-facial bone defect resulting from trauma was reconstructed with this method. The EBCT scanning showed that the defect area was 4 cm x 6 cm. The nose was flat and deviated to left. The 3-dimensional skull was reconstructed with EBCT data and rapid prototyping technique. The model can display the structure of 3-dimensional anatomy and their relationship. The prefabricated implant by 3-dimensional model was well-matched with defect. The deformities of flat and deviated nose were corrected. The clinical result was satisfactory after a follow-up of 17 months. The 3-dimensional model of skull can replicate the prototype of disease and play an important role in the diagnosis and simulation of operation for repairing cranio-maxillo-facial trauma.

  15. Electrophysiologic assessment of regeneration in rat sciatic nerve repair using suture, fibrin glue or a combination of both techniques Avaliação eletrofisiológica da eficácia de três tipos de reparo após a secção do nervo ciático do rato

    Directory of Open Access Journals (Sweden)

    Roberto Sergio Martins

    2005-09-01

    Full Text Available We evaluated the repair of seccioned rat sciatic nerve by the comparison of electrophysiologic parameters. The repair was effected with suture (group A, fibrin glue (group B or a combination of both techniques (group C. The amplitude, latency and conduction velocity of the motor and nerve action potentials were assessed before the nerve section and at reoperation after 24 weeks. There was no difference between the groups when the nerve action potential was evaluated. Rats of group B presented better results than those of group A (pForam comparados os parâmetros obtidos na avaliação eletrofisiológica do potencial de ação do nervo e do potencial de ação motor antes e após 24 semanas do reparo no nervo ciático do rato previamente seccionado no lado direito com a utilização de sutura (grupo A, adesivo de fibrina (grupo B ou uma combinação das duas técnicas (grupo C. Não houve diferença entre os grupos na avaliação do potencial de ação do nervo. Quando consideradas a latência e a velocidade de condução mensurados na reoperação e a razão entre a velocidade de condução medida na reoperação e o mesmo parâmetro antes da secção do nervo, durante a mensuração do potencial de ação motor, os animais do grupo B apresentaram melhores resultados em relação aos do grupo A (p<0,05. Os animais do grupo C apresentaram melhores resultados em comparação com os do grupo A quando considerada a razão entre a velocidade de condução medida 24 semanas do reparo e antes da secção do nervo durante a avaliação do potencial de ação motor. Conclui-se que os animais em que o reparo dos nervos foi realizado com o adesivo de fibrina apresentaram melhores resultados em comparação com a sutura quando considerados os parâmetros obtidos na mensuração do potencial de ação motor.

  16. Surfactant-induced skin irritation and skin repair: evaluation of a cumulative human irritation model by noninvasive techniques.

    Science.gov (United States)

    Wilhelm, K P; Freitag, G; Wolff, H H

    1994-12-01

    Although surfactant-induced acute irritant dermatitis has been extensively studied, our understanding about the induction and repair of the clinically more relevant chronic form is limited. Our purpose was to investigate qualitative and quantitative differences in surfactant-induced irritant skin reactions from cumulative exposure to structurally unrelated surfactants and to compare the maximal irritant responses from this model with corresponding reactions noted in a previously reported acute irritation model. Sodium lauryl sulfate (SLS), dodecyl trimethyl ammonium bromide (DTAB), and potassium soap were the model irritants. Surfactant solutions (7.5%) were applied for 20 minutes daily (for 8 consecutive days excluding the weekend) to the volar aspect of the forearm of 11 volunteers. Irritant reactions were repeatedly assessed until complete healing was indicated by visual assessment and by measurements of transepidermal water loss (TEWL), erythema (skin color reflectance), and stratum corneum hydration (electrical capacitance). Maximum irritant responses were compared with corresponding reactions from an acute irritation model. TEWL was increased by SLS and DTAB to the same extent, but erythema was significantly higher in DTAB-treated skin. Skin dryness, as demonstrated by decreased capacitance values and increased scores for scaling and fissuring, was significantly more pronounced than in an acute irritation model for SLS and DTAB, although no difference was detected between the two surfactants. Potassium soap led to a slight increase in TEWL, whereas the remaining features were not significantly changed. This chronic irritation model appears to represent the clinical situation of irritant contact dermatitis with pronounced skin dryness more closely than the acute irritation model. The present study confirms that an extended time is needed for complete healing of irritant skin reactions. We also demonstrated that the evaluation of the irritation potential of

  17. Efficacy and safety of Elevate® system on apical and anterior compartment prolapse repair with personal technique modification

    Directory of Open Access Journals (Sweden)

    Daniele Castellani

    Full Text Available ABSTRACT Aim: To evaluate the effectiveness and safety of Anterior Elevate® mesh kit system (AES in woman with symptomatic stage 3 or 4 anterior and/or apical pelvic organ prolapse (POP. Materials and Methods: This retrospective, monocentric, single surgeon study enrolled between May 2010 and January 2013 fifty-six woman experiencing symptomatic anterior vaginal prolapse with or without apical descent (POP-Q stage 3 or 4. All women received a AES and 7 (12.5% received a concomitant transvaginal hysterectomy. Primary endpoint was anatomic correction of prolapse; success was defined as POP-Q stage ≤ 1 or asymptomatic stage 2. Secondary endpoints were quality-of-life (QOL results and patients' safety outcomes, which were assessed by 3 validated self-reporting questionnaires at baseline and annually: ICIQ-UI short form, ICIQ-VS and P-QOL. All patients completed 2-years and 28 women 3-years of follow-up. Surgical approach was modified in women with uterus, moving the two-propylene strips anteriorly around the cervix itself crossing one another, so the left will take place in the right side and the right on the opposite. This modification was made in order to better support the uterus. Results: Vaginal mesh exposure was present in 3 (5,3% patients. Very good anatomical outcomes were seen, with one (1,8% failure at 6-months, 4 (7,1% at 1-year, 6 at 2-years (10,7%. Statistically significant improvements were seen in the ICIQ-VS and P-QOL questionnaires throughout follow-up. Conclusion: Our data suggest that AES is a minimally-invasive transvaginal procedure to repair anterior and apical POP, with good evidence related to mid-term safety and efficacy.

  18. A sample speed control technique and pulsating torque elimination method in a brush less D C motor

    International Nuclear Information System (INIS)

    Faiz, J.; Aboulghasemian Azami, M.

    2000-01-01

    This paper presents a theoretical derivation and computer simulation of an optimal speed controller for a barrelhouse dc motor using feedback from a linear model running in parallel with the inverter-fed model. The intent of the feedback from the linear model is to eliminate torque ripples from the inverter drive. A nonlinear model of such a motor, transformed into a linear model by a local dipheomorphism (defined in section 2) and a new model is introduced in order to eliminate the undesirable effects of the inverter harmonics

  19. Determination of damage and In vivo DNA repairing through the unicellular in gel electrophoresis technique; Determinacion del dano y la reparacion del ADN In vivo mediante la tecnica de electroforesis unicelular en gel

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M.T.; Morales R, P. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The experimental conditions were standardized for the unicellular in gel electrophoresis technique setting up (EUG) at the Cellular Radiobiology laboratory. Preliminary experiments were realized with human cells and mouse which were exposed to ionizing radiation or hydroxide peroxide (H{sub 2}O{sub 2}) to induce DNA damage and to verify the technique performance. It was analysed the In vivo repairing kinetics of induced damage by gamma radiation in mouse leukocytes which were exposed to {sup 137} Cs source and taking samples of peripheric blood of the tail of each mouse at different exposure times and processing them for EUG. In function of the cells proportion with damage in each time it was determined the existence of fast repairing mechanism at the first 15 minutes followed by a slight increase in the damage and a late repairing stage between 30 and 90 minutes. It was analysed this behavior and the potentiality of this In vivo system. (Author)

  20. Electric Motor Thermal Management

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-01

    Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

  1. Learning from tradition. Construction techniques and repair of historical buildings in the area of Brescia: some examples

    Directory of Open Access Journals (Sweden)

    Barbara Scala

    2016-06-01

    The essay focuses on the area of Brescia where, in spite of significant transformations over time of buildings and territory, many examples of traditional architecture still exist. The aim of the paper is also to suggest, by presenting some case studies, a strategy for conservation which proposes a dialogue between traditional methods, technological innovations and economic sustainability of interventions. Keywords: Traditional architecture, Brescia, Sustainability, Construction techniques, Protection

  2. Ex vivo hydrodynamics after central and paracommissural edge-to-edge technique: A further step toward transcatheter tricuspid repair?

    Science.gov (United States)

    Stock, Sina; Bohm, Heidemarie; Scharfschwerdt, Michael; Richardt, Doreen; Meyer-Saraei, Roza; Tsvelodub, Stanislav; Sievers, Hans-Hinrich

    2018-03-01

    Transcatheter approaches in heart valve disease became tremendously important and are currently established in the aortic position, but transcatheter tricuspid repair is still in its beginning and remains challenging. Replicating the surgical edge-to-edge technique, for example, with the MitraClip System (Abbott Vascular, Santa Clara, Calif), represents a promising option and has been reported successfully in small numbers of cases. However, up to now, few data considering the edge-to-edge technique as a transcatheter approach are available. This study aims to determine the ex vivo hydrodynamics after the central and paracommissural edge-to-edge technique in different pathologies. Because of basal or apical dislocation of papillary muscles, leaflet prolapse or tethering was simulated in porcine tricuspid valves mounted on a flexible holding device. Central and paracommissural edge-to-edge techniques were evaluated successively in these pathologies. Regurgitant volume and mean transvalvular gradient were determined in a pulse duplicator. In this ex vivo model, the isolated edge-to-edge technique reduced tricuspid regurgitation. In the prolapse model, regurgitant volume decreased significantly after central edge-to-edge technique (from 49.4 ± 13.6 mL/stroke to 39.3 ± 14.1 mL/stroke). In the tethering model, both the central and the paracommissural edge-to-edge techniques led to a significant decrease (from 48.7 ± 13.9 to 43.6 ± 15.6 and to 41.1 ± 13.8 mL/stroke). In all cases, the reduction of regurgitant volume was achieved at the cost of significantly increased mean transvalvular gradient. This study provides a reduction of tricuspid regurgitation after the edge-to-edge technique in the specific experimental setup. Whether this reduction is sufficient to treat tricuspid regurgitation successfully in clinical practice remains to be established. Transcatheter approaches need to be evaluated further, probably with regard to concomitant annuloplasty

  3. Electric motor handbook

    CERN Document Server

    Chalmers, B J

    2013-01-01

    Electric Motor Handbook aims to give practical knowledge in a wide range of capacities such as plant design, equipment specification, commissioning, operation and maintenance. The book covers topics such as the modeling of steady-state motor performance; polyphase induction, synchronous, and a.c. commutator motors; ambient conditions, enclosures, cooling and loss dissipation; and electrical supply systems and motor drives. Also covered are topics such as variable-speed drives and motor control; materials and motor components; insulation types, systems, and techniques; and the installation, sit

  4. Electrocorticographic Temporal Alteration Mapping: A Clinical Technique for Mapping the Motor Cortex with Movement-Related Cortical Potentials

    Directory of Open Access Journals (Sweden)

    Zehan Wu

    2017-06-01

    Full Text Available We propose electrocorticographic temporal alteration mapping (ETAM for motor cortex mapping by utilizing movement-related cortical potentials (MRCPs within the low-frequency band [0.05-3] Hz. This MRCP waveform-based temporal domain approach was compared with the state-of-the-art electrocorticographic frequency alteration mapping (EFAM, which is based on frequency spectrum dynamics. Five patients (two epilepsy cases and three tumor cases were enrolled in the study. Each patient underwent intraoperative direct electrocortical stimulation (DECS procedure for motor cortex localization. Moreover, the patients were required to perform simple brisk wrist extension task during awake craniotomy surgery. Cross-validation results showed that the proposed ETAM method had high sensitivity (81.8% and specificity (94.3% in identifying sites which exhibited positive DECS motor responses. Moreover, although the sensitivity of the ETAM and EFAM approaches was not significantly different, ETAM had greater specificity compared with EFAM (94.3 vs. 86.1%. These results indicate that for the intraoperative functional brain mapping, ETAM is a promising novel approach for motor cortex localization with the potential to reduce the need for cortical electrical stimulation.

  5. Vertical-to-Horizontal Rotational Myocutaneous Flap for Repairing Cicatricial Lower Lid Ectropion: A Novel Surgical Technique

    Directory of Open Access Journals (Sweden)

    Yu-Fan Chang

    2017-01-01

    Full Text Available Objective. To evaluate the efficacy and complications of a novel surgical technique for cicatricial lower lid ectropion that uses a vertical-to-horizontal (V-to-H rotational myocutaneous flap procedure (Tsai procedure. Methods. We performed the V-to-H rotational myocutaneous flap procedure on 20 eyelids in 20 patients with mild to moderate cicatricial lower lid ectropion. A vertical myocutaneous flap was created from the anterior lamella of the vertical pedicle in the lateral third of the lower eyelid. Following a horizontal relaxing incision from the base of the flap, a vertical myocutaneous flap was created and rotated to horizontal. Two patients with combined cicatricial ectropion and paralytic lagophthalmos simultaneously underwent additional lateral tarsorrhaphy. Results. After a minimum follow-up period of 6 months, all patients showed good anatomical and functional improvement with decreased dependence on topical lubricants and a satisfactory cosmetic appearance. Two patients with combined cicatricial and paralytic ectropion had mild residual asymptomatic lagophthalmos. No patients required further revision surgery and there were no complications or recurrence. Conclusion. The V-to-H rotational myocutaneous flap technique was an effective and simple one-stage procedure for correcting cicatricial lower lid ectropion. It lengthened the anterior lamella and tightened horizontal eyelid laxity without the need for a free skin graft.

  6. A study of everyday repair: informing interaction design

    OpenAIRE

    Maestri, Leah Adriana

    2012-01-01

    Repair is typically seen in design as the restoration of broken objects to their original state. Repair by non-experts, or everyday repair, can often lead to novel forms of repair resulting in the creative repurposing of objects that are often unforeseen by designers. Using a grounded theory approach, this study describes key aspects of repair including: the techniques non-experts employ for repairing their objects; the motivations that prompt acts of repair; and the outcomes that result fr...

  7. Toward a more rationalized use of a special technique for repair of frontal air sinus after cerebral aneurysm surgery: The most effective technique

    Directory of Open Access Journals (Sweden)

    Ittichai Sakarunchai, MD

    2016-06-01

    Full Text Available A craniotomy that passes through the frontal air sinus (FAS often results in postoperative complications such as infection, cerebrospinal fluid leakage or mucocele formation. A good understanding of FAS reconstruction can decrease the morbidity rate of complications. This study describes the outcomes of treatment and establishes the most effective technique for FAS reconstruction in our institution. We enrolled 107 patients who had a bifrontal craniotomy which exposed the FAS during the operation for an anterior communicating artery (ACoA aneurysm. Demographic data including the follow-up information were collected and analyzed. The complications after surgery were observed and described in the treatment procedure. The patency of the nasofrontal outflow tract (NFOT was proved by removal of blood clots and bone dust by irrigation and by direct inspection under a microscope before closure of the frontal sinus mucosa with a monofilament non-absorbable 7/0 material suture. The dura was closed in a watertight fashion and an abdominal fat graft was packed into the FAS cavity. There were 33 male and 74 female patients and the mean age (range was 64 years (32–90 years. The mean follow-up time was 13 months (1–35 months and complications were found in only 2 patients. One patient suffered from dislocation of the fat graft and the other patient developed a surgical wound infection. At post-operation the first patient sneezed several times and the second patient suffered from trauma in the nasal area after discharge to home. Both patients were surgically treated and cured. In conclusion, FAS reconstruction from our technique is very effective for the prevention of complications after bifrontal craniotomy. Direct suturing of the frontal sinus mucosa and proving the patency of the NFOT are keys to successful treatment.

  8. Sodium magnetic resonance imaging of ankle joint in cadaver specimens, volunteers, and patients after different cartilage repair techniques at 7 T: initial results.

    Science.gov (United States)

    Zbýň, Štefan; Brix, Martin O; Juras, Vladimir; Domayer, Stephan E; Walzer, Sonja M; Mlynarik, Vladimir; Apprich, Sebastian; Buckenmaier, Kai; Windhager, Reinhard; Trattnig, Siegfried

    2015-04-01

    The goal of cartilage repair techniques such as microfracture (MFX) or matrix-associated autologous chondrocyte transplantation (MACT) is to produce repair tissue (RT) with sufficient glycosaminoglycan (GAG) content. Sodium magnetic resonance imaging (MRI) offers a direct and noninvasive evaluation of the GAG content in native cartilage and RT. In the femoral cartilage, this method was able to distinguish between RTs produced by MFX and MACT having different GAG contents. However, it needs to be clarified whether sodium MRI can be useful for evaluating RT in thin ankle cartilage. Thus, the aims of this 7-T study were (1) to validate our sodium MRI protocol in cadaver ankle samples, (2) to evaluate the sodium corrected signal intensities (cSI) in cartilage of volunteers, (3) and to compare sodium values in RT between patients after MFX and MACT treatment. Five human cadaver ankle samples as well as ankles of 9 asymptomatic volunteers, 6 MFX patients and 6 MACT patients were measured in this 7-T study. Sodium values from the ankle samples were compared with histochemically evaluated GAG content. In the volunteers, sodium cSI values were calculated in the cartilages of ankle and subtalar joint. In the patients, sodium cSI in RT and reference cartilage were measured, morphological appearance of RT was evaluated using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system, and clinical outcome before and after surgery was assessed using the American Orthopaedic Foot and Ankle Society score and Modified Cincinnati Knee Scale. All regions of interest were defined on morphological images and subsequently transferred to the corresponding sodium images. Analysis of variance, t tests, and Pearson correlation coefficients were evaluated. In the patients, significantly lower sodium cSI values were found in RT than in reference cartilage for the MFX (P = 0.007) and MACT patients (P = 0.008). Sodium cSI and MOCART scores in RT did not differ between

  9. Plastia da valva mitral com a técnica do "Duplo Teflon": resultados de 10 anos Mitral valve repair with "Double Teflon" technique: 10-year results

    Directory of Open Access Journals (Sweden)

    Carlos Manuel de Almeida Brandão

    2007-12-01

    Full Text Available OBJETIVO: O objetivo deste trabalho é apresentar os resultados clínicos tardios da plástica da valva mitral com a técnica do "Duplo Teflon". MÉTODOS: A plástica de "Duplo Teflon" consiste em técnica de reparo mitral com ressecção quadrangular da cúspide posterior, anuloplastia segmentar com plicatura do anel com de fios com "pledgets" sobre uma tira de Teflon, e sutura borda a borda da cúspide. Entre abril de 1994 e dezembro de 2003, 133 pacientes com diagnóstico de insuficiência mitral degenerativa com alongamento ou rotura de cordas da cúspide posterior foram submetidos à plástica com esta técnica. A idade média foi de 60,4 anos e 60,9% eram do sexo feminino. Quanto à avaliação clínica no pré-operatório, 29,3% dos pacientes estavam em classe funcional IV, 55,7% em classe III e 15,0% em classe II. Técnicas associadas de plástica mitral foram utilizadas em 15,2% dos pacientes, sendo a mais comum o encurtamento de cordas. Vinte e seis (19,5% pacientes foram submetidos a operações associadas. RESULTADOS: Houve um (0,75% óbito hospitalar. No período pós-operatório tardio, 95,5% dos sobreviventes estavam em classe funcional I. As taxas linearizadas de tromboembolismo, reoperação e óbito foram 0,9%, 0,3% e 0,6% pacientes/ano, respectivamente. A sobrevida atuarial em 10 anos foi de 94,1% ± 3,6%. As sobrevidas atuariais livre de tromboembolismo e reoperação foram de 97,3 ± 1,5% e 99,2 ± 0,8%, respectivamente. Não houve casos de endocardite ou hemólise. CONCLUSÃO: A plástica da valva mitral com a técnica do "Duplo Teflon" apresenta baixa morbi-mortalidade e boa evolução clínica tardia.OBJECTIVE: The purpose of this paper is to present the late clinical results of mitral valve repair with the "Double Teflon" technique. METHODS: "Double Teflon" technique consists of a quadrangular resection of the posterior leaflet, annulus plication with "pledgetted" stitches over a Teflon patch, and leaflet suture. Between

  10. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    Science.gov (United States)

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  11. Stress Distribution in the Dissimilar Metal Butt Weld of Nuclear Reactor Piping due to the Simulation Technique for the Repair Welding

    International Nuclear Information System (INIS)

    Lee, Hweeseung; Huh, Namsu; Kim, Jinsu; Lee, Jinho

    2013-01-01

    During welding, the dissimilar metal butt welds of nuclear piping are typically subjected to repair welding in order to eliminate defects that are found during post-weld inspection. It has been found that the repair weld can significantly increase the tensile residual stress in the weldment, and therefore, accurate estimation of the weld residual stress due to repair weld, especially for dissimilar metal welds using Ni-based alloy 82/182 in nuclear components, is of great importance in order to assess susceptibility to primary water stress corrosion cracking. In the present study, the stress distributions of dissimilar metal butt welds in nuclear reactor piping subjected to repair weld were investigated based on detailed nonlinear finite element analyses. Particular emphasis was placed on the variation of the stress distribution in the dissimilar metal butt weld according to the finite element welding analysis sequence for the repair welding process

  12. 40 CFR 51.369 - Improving repair effectiveness.

    Science.gov (United States)

    2010-07-01

    ... vehicles that fail I/M tests. (a) Technical assistance. The oversight agency shall provide the repair industry with information and assistance related to vehicle inspection diagnosis and repair. (1) The agency... monitor the performance of individual motor vehicle repair facilities, and provide to the public at the...

  13. 41 CFR 102-34.260 - May we replace a Government-owned motor vehicle sooner?

    Science.gov (United States)

    2010-07-01

    ... mechanical repairs that exceed the fair market value of the motor vehicle. Determine the fair market value by adding the current market value of the motor vehicle plus any capitalized motor vehicle additions (such...

  14. Anophthalmia, cleft lip/palate, absent vomer bone, nystagmus, and mental-motor retardation: a new syndrome or Fryns "anophthalmia-plus" syndrome?

    Science.gov (United States)

    Ozçelik, Derya; Sağlam, Ibrahim; SIlan, Fatma; Sezen, Gülbin; Unveren, Toygar

    2008-05-01

    We report that a 4-year-old boy presented with right unilateral complete cleft lip and palate, right anophthalmos, left congenital nystagmus, absence of the vomer bone, mental-motor retardation, and normal lymphocyte karyotype (46, XY). For reconstruction of the deformities, we performed cleft lip repair by Millard's rotation-advancement technique and planned cleft palate repair. This combination of cleft lip and palate, anophthalmos, congenital nystagmus, absent vomer bone, and mental-motor retardation has not, to our knowledge, previously been described. We suggest that this represents either another case of the rare Fryns "anophthalmia-plus" syndrome or a new syndrome.

  15. Meningocele repair

    Science.gov (United States)

    ... is surgery to repair birth defects of the spine and spinal membranes. Meningocele and myelomeningocele ... is covered by a sterile dressing. Your child may then be transferred to a neonatal intensive ...

  16. Motor degradation prediction methods

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, J.R.; Kelly, J.F.; Delzingaro, M.J.

    1996-12-01

    Motor Operated Valve (MOV) squirrel cage AC motor rotors are susceptible to degradation under certain conditions. Premature failure can result due to high humidity/temperature environments, high running load conditions, extended periods at locked rotor conditions (i.e. > 15 seconds) or exceeding the motor`s duty cycle by frequent starts or multiple valve stroking. Exposure to high heat and moisture due to packing leaks, pressure seal ring leakage or other causes can significantly accelerate the degradation. ComEd and Liberty Technologies have worked together to provide and validate a non-intrusive method using motor power diagnostics to evaluate MOV rotor condition and predict failure. These techniques have provided a quick, low radiation dose method to evaluate inaccessible motors, identify degradation and allow scheduled replacement of motors prior to catastrophic failures.

  17. Laparoscopic Repair of Inguinal Hernias

    OpenAIRE

    Carter, Jonathan; Duh, Quan-Yang

    2011-01-01

    For patients with recurrent inguinal hernia, or bilateral inguinal hernia, or for women, laparoscopic repair offers significant advantages over open techniques with regard to recurrence risk, pain, and recovery. For unilateral first-time hernias, either laparoscopic or open repair with mesh can offer excellent results. The major drawback of laparoscopy is that the technique requires a significant number of cases to master. For surgeons in group practice, it makes sense to have one surgeon in ...

  18. Transformers and motors

    CERN Document Server

    Shultz, George

    1991-01-01

    Transformers and Motors is an in-depth technical reference which was originally written for the National Joint Apprenticeship Training Committee to train apprentice and journeymen electricians. This book provides detailed information for equipment installation and covers equipment maintenance and repair. The book also includes troubleshooting and replacement guidelines, and it contains a minimum of theory and math.In this easy-to-understand, practical sourcebook, you'll discover:* Explanations of the fundamental concepts of transformers and motors* Transformer connections and d

  19. Sequelae of Endoscopic Inguinal Hernia Repair : Incidence, evaluation and management

    NARCIS (Netherlands)

    Burgmans, J.P.J.

    2015-01-01

    The endoscopic preperitoneal technique (TEP) is an appealing inguinal hernia repair technique, theoretically superior to other approaches. In practice some problems remain unsolved. Real incidences of chronic postoperative inguinal pain (CPIP) and other important sequelae of endoscopic hernia repair

  20. Aircraft Propeller Hub Repair

    Energy Technology Data Exchange (ETDEWEB)

    Muth, Thomas R [ORNL; Peter, William H [ORNL

    2015-02-13

    The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spray coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.

  1. Técnica do retalho pediculado para correção do sulco vocal The pediculated flap technique to sulcus vocalis repairing

    Directory of Open Access Journals (Sweden)

    Marcos Grellet

    Full Text Available Introdução: técnica do retalho pediculado de mucosa para reparar o sulco vocal permite o aparecimento da onda mucosa nessa região. A presença do sulco vocal traz como conseqüência rouquidão, soprosidade e aspereza. Outros sintomas podem estar presentes como fadiga ao falar, queimação ou ardor. Objetivo: provocar o aparecimento de onda mucosa com técnica cirúrgica. Forma de estudo: clínico retrospectivo. Material e método: Foram operados 3 pacientes para auxiliar no deslocamento do epitélio escamoso estratificado e da camada superficial da prega vocal aderidos ao ligamento vocal injetamos pequena quantidade de dexametasona. Obtemos o retalho pediculado descolando retalho de mucosa da prega vocal. Resultados: No pós-operatório, a videoestroboscopia mostra uniformidade do revestimento da cobertura da prega vocal na região do sulco vocal. Nos pacientes operados observamos a presença da onda mucosa nessa região e a coaptação das pregas vocais é satisfatória, no caso de sulco unilateral. A análise subjetiva e objetiva da voz apresenta resultados normais a partir de um ano da cirurgia. Os sintomas, esforço e fadiga ao falar, ardor e queimação, desapareceram nesse período. Para sulco bilateral operamos inicialmente o sulco de uma prega vocal com melhora dos índices acústicos utilizados, embora não atingisse valores normais em todos os parâmetros avaliados no curto período de evolução (30 dias de pós-operatório após realizarmos a correção cirúrgica do sulco da outra prega vocal. Conclusão: A técnica microfonocirúrgica de retalho pediculado de mucosa para correção do sulco vocal mostrou resultados amplamente favoráveis para reabilitação da voz nos três pacientes apresentados.Introduction: the pedicullate flap technique to repair sulcus vocalis allows the appearing of the mucous wave in this region. Sulcus vocalis cause hoarseness, breathing and roughness. Other symptoms can happen during the speech like

  2. Production and repair of chromosome damage in an X-ray sensitive CHO mutant visualized and analysed in interphase using the technique of premature chromosome condensation

    International Nuclear Information System (INIS)

    Iliakis, G.E.; Pantelias, G.E.

    1990-01-01

    Production of chromosome damage per unit of absorbed radiation dose was in xrs-5 cells larger by a factor of 2.6 than in CHO cells (5.2 breaks per cell per Gy). Changes in chromatin structure, associated with the radiation-sensitive pheno-type of xrs-5 cells, that increase the probability of conversion of a DNA double-strand break (dsb) to a chromosome break are invoked to explain this. Repair of chromosome breaks as measured in plateau-phase G 1 cells was deficient in xrs-5 cells and the number of residual chromosome breaks practically identical to the number of lethal lesions calculated from survival data, suggesting that non-repaired chromosome breaks are likely to be manifestations of lethal events in the cell. The yield of ring chromosomes scored after a few hours of repair was higher by a factor of three in xrs-5 compared with CHO cells. (author)

  3. Novel diffusion tensor imaging technique reveals developmental streamline volume changes in the corticospinal tract associated with leg motor control.

    Science.gov (United States)

    Kamson, David O; Juhász, Csaba; Chugani, Harry T; Jeong, Jeong-Won

    2015-04-01

    Diffusion tensor imaging (DTI) has expanded our knowledge of corticospinal tract (CST) anatomy and development. However, previous developmental DTI studies assessed the CST as a whole, overlooking potential differences in development of its components related to control of the upper and lower extremities. The present cross-sectional study investigated age-related changes, side and gender differences in streamline volume of the leg- and hand-related segments of the CST in children. DTI data of 31 children (1-14 years; mean age: 6±4 years; 17 girls) with normal conventional MRI were analyzed. Leg- and hand-related CST streamline volumes were quantified separately, using a recently validated novel tractography approach. CST streamline volumes on both sides were compared between genders and correlated with age. Higher absolute streamline volumes were found in the left leg-related CST compared to the right (p=0.001) without a gender effect (p=0.4), whereas no differences were found in the absolute hand-related CST volumes (p>0.4). CST leg-related streamline volumes, normalized to hemispheric white matter volumes, declined with age in the right hemisphere only (R=-.51; p=0.004). Absolute leg-related CST streamline volumes showed similar, but slightly weaker correlations. Hand-related absolute or normalized CST streamline volumes showed no age-related variations on either side. These results suggest differential development of CST segments controlling hand vs. leg movements. Asymmetric volume changes in the lower limb motor pathway may be secondary to gradually strengthening left hemispheric dominance and is consistent with previous data suggesting that footedness is a better predictor of hemispheric lateralization than handedness. Copyright © 2014 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  4. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  5. Proximity of the Triangular Fibrocartilage Complex to Key Surrounding Structures and Safety Assessment of an Arthroscopic Repair Technique: A Cadaveric Study.

    Science.gov (United States)

    Kuremsky, Marshall A; Habet, Nahir; Peindl, Richard D; Gaston, R Glenn

    2016-12-01

    To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and secondarily to assess the safety of an all-inside arthroscopic repair of the TFCC with a commonly used meniscal repair device with respect to the aforementioned structures. A custom K-wire with 1-mm gradation was used to determine the distance of at-risk structures from the periphery of the TFCC in 13 above-elbow human cadaver specimens. An all-inside repair of the TFCC at the location of a Palmer 1B tear was then performed using a commonly employed meniscal repair device. The distance from the deployed devices to the structure in closest proximity was then measured using digital calipers. The mean distance from the deployed device to the nearest structure of concern for iatrogenic injury was 9.4 mm (range, 5-15 mm). The closest structure to iatrogenic injury was usually, but not always, the dorsal ulnar sensory nerve in 9 of 13 wrists (69.2%) at 9.3 mm (range, 5-15 mm); on 3 occasions it was instead the ulnar nerve (23.1%) at 9.5 mm (range, 9-10 mm), and on 1 occasion 6 mm from the flexor digitorum profundus to the little finger (7.7%). Forearm rotation had no significant effect on measured distances (ulnar nerve: P = .98; dorsal sensory: P = .89; ECU: P = .90). The largest influence of forearm rotation was a 0.4-mm difference between pronation and supination with respect to the distance of the TFCC periphery on the ECU subsheath. An all-inside arthroscopic TFCC repair using a commonly used meniscal repair device appears safe with respect to nearby neurovascular structures and tendons under typical arthroscopic conditions. An all-inside arthroscopic TFCC repair using a commonly employed meniscal repair device appears safe in terms of proximity to important structures although further clinical investigation is warranted. Copyright © 2016 Arthroscopy

  6. Motor Neurons

    DEFF Research Database (Denmark)

    Hounsgaard, Jorn

    2017-01-01

    Motor neurons translate synaptic input from widely distributed premotor networks into patterns of action potentials that orchestrate motor unit force and motor behavior. Intercalated between the CNS and muscles, motor neurons add to and adjust the final motor command. The identity and functional...... in in vitro preparations is far from complete. Nevertheless, a foundation has been provided for pursuing functional significance of intrinsic response properties in motoneurons in vivo during motor behavior at levels from molecules to systems....

  7. The Impact of Re-tear on the Clinical Outcome after Rotator Cuff Repair Using Open or Arthroscopic Techniques – A Systematic Review

    Science.gov (United States)

    Galanopoulos, Ilias; Ilias, Aslanidis; Karliaftis, Konstantinos; Papadopoulos, Dimitrios; Ashwood, Neil

    2017-01-01

    Background: It is generally accepted that rotator cuff repair gives satisfactory results in the long term, although most studies have so far shown a fairly high rate of structural failure or re-tear. The purpose of this review study is to assess whether failure of the repaired cuff to heal could negatively affect the functional outcome. Methods: This article includes an extensive Internet PubMed based research in the current English-language literature including level I to level V studies as well as systematic reviews. Results: According to this extended study research, the results are mixed; certain reports show that patients with a healed rotator cuff repair have improved function and strength compared to those with structural failure, whereas other studies support the generally perceived concept that tendon re-tear does not lead to inferior clinical outcome. Conclusion: Further high-level prospective studies with larger numbers of patients and longer follow up are needed to overcome the current debate over function between healed and failed rotator cuff repairs. PMID:28400878

  8. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  9. Motor degradation prediction methods

    International Nuclear Information System (INIS)

    Arnold, J.R.; Kelly, J.F.; Delzingaro, M.J.

    1996-01-01

    Motor Operated Valve (MOV) squirrel cage AC motor rotors are susceptible to degradation under certain conditions. Premature failure can result due to high humidity/temperature environments, high running load conditions, extended periods at locked rotor conditions (i.e. > 15 seconds) or exceeding the motor's duty cycle by frequent starts or multiple valve stroking. Exposure to high heat and moisture due to packing leaks, pressure seal ring leakage or other causes can significantly accelerate the degradation. ComEd and Liberty Technologies have worked together to provide and validate a non-intrusive method using motor power diagnostics to evaluate MOV rotor condition and predict failure. These techniques have provided a quick, low radiation dose method to evaluate inaccessible motors, identify degradation and allow scheduled replacement of motors prior to catastrophic failures

  10. Comparative Study of Modulation-Based Individual Inverter Techniques for Direct and Inverse by using Star-Connection Induction Motor in Extra Low Voltage Application

    Directory of Open Access Journals (Sweden)

    Ardhia Wishnuprakasa

    2016-12-01

    Full Text Available In this study, the IEEE 519 Standard as a basis benchmarking for voltage (THDV and current (THDI in draft performance. Comparative Study based onthree-techniques of 2-Level Converter (2LC by using a Star-Connection Induction Motor (Y-CIM in ExtraLow Voltage (ELV Configuration.For the detail explanation, a primary inverter as Direct-Inverterby PWMdirect (PWM degreesand asecondary inverter as Inverse-Inverterby PWMinverse(PWM + PI degrees. It tends a modified algorithm,for eachof SPWM in six rules, and FHIPWM in 5th harmonics Injectedin standard modulation as the purpose for the Open-Ends of Pre-Dual Inverter in Decoupled SPWM for twelve rules, and Decoupled FHIPWM in combination of 5th harmonics Injectedin combination of two-standard-modulation. Those techniques are the purpose of two-inverter combination, which namelythe Equal Direct-Inverse (EDI algorithmproduct of prototyping in similarities. The observation is restricted in voltage scope between Simulation by using Power Simulator (PSIMand Application by using Microcontroller ARM STM32F4 Discovery.

  11. Sliding mode controller gain adaptation and chattering reduction techniques for DSP-based PM DC motor drives

    DEFF Research Database (Denmark)

    Dal, Mehmet; Teodorescu, Remus

    2011-01-01

    In order to achieve and maintain the prospective benefits of sliding mode control (SMC) methodology, the phenomenon known as “chattering”, the main obstacle encountered in real-time applications, has to be suppressed. In this study, two promising switching control gain adaptation and chattering...... reduction techniques are investigated, and the effectiveness of chattering suppression for current regulation of PM DC drives is tested. The sampling rate was also examined to determine how it affects the amplitude of chattering. This paper concentrates on various combinations of observer-based methods...... in order to find the best solution for chattering reduction. To find a practical solution a tunable low-pass filter (LPF) was used to average the discontinuous control term. The validity of the existing conditions for the gain adaptation methods are examined and observer gain value was determined through...

  12. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  13. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  14. Plan Repair as an Extension of Planning

    NARCIS (Netherlands)

    Van der Krogt, R.P.J.; De Weerdt, M.M.

    2005-01-01

    In dynamic environments, agents have to deal with changing situations. In these cases, repairing a plan is often more efficient than planning from scratch, but existing planning techniques are more advanced than existing plan repair techniques. Therefore, we propose a straightforward method to

  15. Innovative repair of subsidence damage

    International Nuclear Information System (INIS)

    Marino, G.G.

    1992-01-01

    In order to improve handling of subsidence damages the Illinois Mine Subsidence Insurance Fund supported the development of novel cost-effective methods of repair. The research in developing the repairs was directed towards the most common and costly damages that had been observed. As a result repair techniques were designed for structurally cracked foundations in the tension zone; structurally cracked foundations in the compression zone; and damaged or undamaged tilted foundations. When appropriate the postulated methods would result in: 1. significant cost savings (over conventional procedures); 2. a structural capacity greater than when the foundation was uncracked; and 3. an aesthetic appeal. All the postulated repair methodologies were laboratory and/or field tested. This paper will summarize the essentials of each technique developed and the test results

  16. Technique Tip: The Use of McGlamry Elevator to Assist Suture Passing in the Dorsal Technique of Plantar Plate Repair With Weil Osteotomy for Lesser Metatarsophalangeal Joint Instability.

    Science.gov (United States)

    Sullivan, Martin; Panti, Juan Paulo

    2015-06-01

    The combination of a dorsal approach to the plantar plate with a Weil's metatarsal osteotomy has been shown to provide an adequate exposure for plantar plate repair. However, soft tissues in a restricted area of the metatarsophalangeal joint could present as a technical difficulty during suture retrieval during repair of the plantar plate. The purpose of this article is to describe the use of the McGlamry elevator for assistance in the retrieval of sutures through the proximal phalanx. Level V: Expert opinion. © 2015 The Author(s).

  17. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  18. Valve repair for traumatic tricuspid regurgitation.

    Science.gov (United States)

    Maisano, F; Lorusso, R; Sandrelli, L; Torracca, L; Coletti, G; La Canna, G; Alfieri, O

    1996-01-01

    The review of six cases of valve repair for traumatic tricuspid regurgitation in our institution and 74 in the literature in order to assess effective methods of treating this lesion. Tricuspid valve regurgitation is a rare complication of blunt chest trauma. Optimal treatment for this condition is still controversial ranging from long-term medical therapy to early surgical correction. We followed the cases of six consecutive patients with post-traumatic tricuspid incompetence who were successfully treated with reparative techniques. All patients were male and their ages ranged from 18 years to 42 years. Valve regurgitation was always secondary to blunt chest trauma due to motor vehicle accident. The mechanism of valve insufficiency was invariably anterior leaflet prolapse due to chordal or papillary muscle rupture associated with annular dilatation. Surgical procedures included Carpentier ring implant (5 patients), Bex posterior annuloplasty (1 patient), implant of artificial chordae (4 patients), papillary muscle reinsertion (2 patients), commissuroplasty (1 patient) and "artificial double orifice" technique (1 patient). Tricuspid insufficiency improved in all patients after the correction. No complications were recorded and all patients were asymptomatic at the follow-up. Since post-traumatic tricuspid regurgitation is effectively correctable with reparative techniques, early operation is recommended to relieve symptoms and to prevent right ventricular dysfunction.

  19. A biomechanical and histological comparison of the suture bridge and conventional double-row techniques of the repair of full-thickness rotator cuff tears in a rabbit model.

    Science.gov (United States)

    Fei, Wenyong; Guo, Weichun

    2015-06-16

    The suture bridge (SB) technique and conventional double-row (DR) are both effective in repair of full-thickness rotator cuff tears . However, increasing numbers of scholars believe that the SB technique produces better results than conventional DR because of the higher bone-tendon contact area and pressure. However, The clinical outcomes have been mixed and little direct evidence has been supplied in vivo. This study was designed using the SB and DR techniques to determine which is the better technique. Sixty-four New Zealand white rabbits were randomly divided into 2 groups, the SB group and DR group. SB and DR were then used to repair their rotator cuff tears. Rabbits were then sacrificed at the 2(nd), 4(th), or 8(th) week after surgery and a histological comparison was made. The biomechanical comparison was made at the 8(th) week. The load to failure of the SB group was 134.59 ± 17.69 N at the 8(th) postoperative week, and that was significantly higher than in the DR group (103.83 ± 6.62, P = 0.001), but both repair groups remained lower than in the control group (199.25 ± 14.81). Histological evaluation showed that both the SB and DR groups healed at the bone-tendon interface. But there were subtle differences between the two groups in the structure and morphology of collagen fibers and cartilage cells at bone-tendon interface. In general, the collagen fibers of the SB group were more compact than those of the DR group at all times tested. At the 4(th) and 8(th) weeks, the collagen fibers and cartilage cells in the SB group were arranged in a column modality, but those in the DR group were distributed horizontally. The SB technique facilitated healing more effectively than the conventional DR technique. The difference in morphology of collagen fibers and cartilage cells may be related to the difference in bone-tendon contact pressure.

  20. Control allocation for for regenerative braking of electric vehicles with an electric motor at the front axle using the state-dependent Riccati equation control technique

    NARCIS (Netherlands)

    Kanarachos, S.A.; Alirezaei, M.; Jansen, S.T.H.; Maurice, J.P.

    2014-01-01

    In this paper the systematic development of an integrated braking controller for a vehicle driven by an electric motor on the front axle is presented. The objective is to engage the electric motor only during braking, up to the point at which the vehicle reaches its manoeuvrability and stability

  1. The combined use of scanning vibrating electrode technique and micro-potentiometry to assess the self-repair processes in defects on 'smart' coatings applied to galvanized steel

    Energy Technology Data Exchange (ETDEWEB)

    Taryba, M. [ICEMS, Instituto Superior Tecnico, UTL, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); Lamaka, S.V., E-mail: sviatlana.lamaka@ist.utl.p [ICEMS, Instituto Superior Tecnico, UTL, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); Snihirova, D. [ICEMS, Instituto Superior Tecnico, UTL, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); Ferreira, M.G.S. [ICEMS, Instituto Superior Tecnico, UTL, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); CICECO, Dep. Ceramics and Glass Eng., University of Aveiro, 3810-193 Aveiro (Portugal); Montemor, M.F. [ICEMS, Instituto Superior Tecnico, UTL, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); Wijting, W.K.; Toews, S.; Grundmeier, G. [Institute for Polymer Materials and Processes, University of Paderborn, 33098 Paderborn (Germany)

    2011-04-30

    Research highlights: {yields} Weldable primers were modified with submicron containers loaded with corrosion inhibitors. {yields} SVET and micro-potentiometry were used to study the corrosion inhibition ability. {yields} Submicron containers do not damage the barrier properties of model primers. {yields} Artificial defects of 50{mu}m x 50 {mu}m in a coating can be easily analyzed by SVET and SIET. {yields} Inhibiting dissolution of sacrificial Zn may result in detrimental dissolution of Fe. - Abstract: Model weldable primer coatings for galvanized steel were modified with submicron containers loaded with corrosion inhibitors. This procedure aims at introducing a new functionality in the thin coatings self-repair ability. The assessment of this property demands new protocols and new approaches, combining conventional electrochemical methods with electrochemical and analytical techniques of micrometer spatial resolution. Thus, in this work model defects were created in the coatings by using a focused ion beam (FIB). The coated samples, containing the model defects, were immersed in a NaCl 0.05 M solution and the corrosion inhibition ability was studied using the scanning vibrating electrode technique (SVET) and the scanning ion-selective electrode technique (SIET). SVET-SIET measurements were performed quasi-simultaneously. Qualitative chemical analysis was performed by SEM combined with EDS. Complementary studies were carried out by electrochemical impedance spectroscopy (EIS) to assess the effect of the containers filled with corrosion inhibitors on the barrier properties of the coatings. The electrochemical results highlight the importance of the combined use of integral and localized electrochemical techniques to extract information for a better understanding of the corrosion processes and corresponding repair of active microscopic defects formed on thin coatings containing inhibitor filled containers.

  2. Primary unilateral cleft lip repair

    OpenAIRE

    Adenwalla, H. S.; Narayanan, P. V.

    2009-01-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform clos...

  3. 49 CFR 177.854 - Disabled vehicles and broken or leaking packages; repairs.

    Science.gov (United States)

    2010-10-01

    ... spark producing devices to repair or maintain the cargo or fuel containment system of a motor vehicle... to contain cargo or fuel during loading or filling, transport, or unloading. (2) Repair and... repair of a cargo tank used for the transportation of any Class 3 (flammable liquid) or Division 6.1...

  4. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  5. FLEXOR TENDON REPAIR IN THE HAND

    African Journals Online (AJOL)

    Method of Repair. Cases. AGE, SEX ... method is at fault and not the dexterity of the operator or his technique. .... Physio- therapy seldom makes stiff fingers work, but it prevents .... or repaired later by direct suture, graft or transplant. No. of.

  6. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  7. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  8. Scarf Repair of Composite Laminates

    Directory of Open Access Journals (Sweden)

    Xie Zonghong

    2016-01-01

    Full Text Available The use of composite materials, such as carbon-fiber reinforced plastic (CFRP composites, aero-structures has led to an increased need of advanced assembly joining and repair technologies. Adhesive bonded repairs as an alternative to recover full or part of initial strength were investigated. Tests were conducted with the objective of evaluating the effectiveness of techniques used for repairing damage fiber reinforced laminated composites. Failure loads and failure modes were generated and compared with the following parameters: scarf angles, roughness of grind tool and number of external plies. Results showed that scarf angle was the critical parameter and the largest tensile strength was observed with the smallest scarf angle. Besides, the use of external plies at the outer surface could not increase the repairs efficiency for large scarf angle. Preparing the repair surfaces by sanding them with a sander ranging from 60 to 100 grit number had significant effect on the failure load. These results allowed the proposal of design principles for repairing CFRP structures.

  9. Imaging of cartilage repair procedures

    International Nuclear Information System (INIS)

    Sanghvi, Darshana; Munshi, Mihir; Pardiwala, Dinshaw

    2014-01-01

    The rationale for cartilage repair is to prevent precocious osteoarthritis in untreated focal cartilage injuries in the young and middle-aged population. The gamut of surgical techniques, normal postoperative radiological appearances, and possible complications have been described. An objective method of recording the quality of repair tissue is with the magnetic resonance observation of cartilage repair tissue (MOCART) score. This scoring system evaluates nine parameters that include the extent of defect filling, border zone integration, signal intensity, quality of structure and surface, subchondral bone, subchondral lamina, and records presence or absence of synovitis and adhesions. The five common techniques of cartilage repair currently offered include bone marrow stimulation (microfracture or drilling), mosaicplasty, synthetic resorbable scaffold grafts, osteochondral allograft transplants, and autologous chondrocyte implantation (ACI). Complications of cartilage repair procedures that may be demonstrated on magnetic resonance imaging (MRI) include plug loosening, graft protuberance, graft depression, and collapse in mosaicplasty, graft hypertrophy in ACI, and immune response leading to graft rejection, which is more common with synthetic grafts and cadaveric allografts

  10. Electric motor predictive and preventive maintenance guide

    International Nuclear Information System (INIS)

    Oliver, J.A.

    1992-07-01

    Electric motor performance is vital to the reliable and efficient operation of power plants. The failure of one or more critical motors could cause lost capacity and excessive repair and maintenance cost. However, existing maintenance recommendations proposed by vendors for electric motors have sometimes encouraged many overly conservative maintenance practices. These practices have lead to excessive maintenance activities and costs which have provided no extra margin of operability. EPRI has sponsored RP2814-35 to develop a guide which provides power plants with information and guidance for establishing an effective maintenance program which will aid in preventing unexpected motor failures and assist in planning motor maintenance efforts. The guide includes a technical description which summarizes technical data relative to the four basic types of motors and their components in general use in power plants. The significant causes of motor failures are investigated and described in detail and methods to optimize service life and minimize maintenance cost through appropriate preventive maintenance and conditioning program are presented. This guide provides a foundation for an effective electric motor maintenance program and simplifies the selection of predictive and preventive maintenance tasks. Its use will enable maintenance personnel in nuclear and fossil plants to plan motor repairs during scheduled outages and avoid costly unexpected failures

  11. MOTORIC STIMULATION RELATED TO FINE MOTORIC DEVELOPMENT ON CHILD

    Directory of Open Access Journals (Sweden)

    Mira Triharini

    2017-07-01

    Full Text Available Introduction: Motor developmental stimulation is an activity undertaken to stimulate the children basic skills and so they can grow and develop optimally. Children who obtain a direct stimulus will grow faster than who get less stimulus. Mother’s behavior of stimulation is very important for children, it is considering as the basic needs of children and it must be fulfilled. Providing good stimulation could optimize fine motor development in children. The purpose of this study was to analyze mother’s behavior about motor stimulation with fine motor development in toddler age 4-5 years old. Method: Design have been  used in this study was cross sectional. Population were mothers and their toddler in Group A of Dharma Wanita Persatuan Driyorejo Gresik Preschool. Sample were 51 respondents recruited by using purposive sampling technique according to inclusion and exclusion criteria. The independent variable was mother’s behavior about motor stimulation whereas dependent variable was fine motor development in toddler. The data were collected using questionnaire and conducting observation on fine motor development based on Denver Development Screening Test (DDST. Data then analyzed using Spearman Rho (r test to find relation between mother’s behaviors about stimulation motor on their toddler fine motor development. Result: Results  of this study showed that there were correlations between mother’s knowledge and fine motor development in toddler (p=0.000, between mother’s attitude and fine motor development in toddler (p=0.000, and between mother’s actions and fine motor development in toddler (p=0.000. Analysis: In sort study found that there were relation between fine motor development and mother’s behavior. Discussion: Therefore mother’s behavior needed to be improved. Further research about stimulation motor and fine motor development aspects in toddler is required.

  12. Comparación entre la reparación abierta con malla y la técnica de Desarda en la hernia inguinal Comparison between open repair with mesh and the Desarda technique in inguinal hernia

    Directory of Open Access Journals (Sweden)

    Pedro Rolando López Rodríguez

    2009-12-01

    Full Text Available INTRODUCCIÓN. Con el presente trabajo se buscó dar respuesta a algunas controversias en torno de la reparación de las hernias inguinales, así como realizar una valoración sobre el dolor posoperatorio y analizar los costos de las técnicas de reparación protésicas y la técnica que refuerza la pared posterior del canal inguinal con una franja aponeurótica pediculada del músculo oblicuo mayor. MÉTODOS. Se realizó un estudio prospectivo aleatorio de 836 pacientes con hernia inguinal, operados entre septiembre del 2001 y diciembre del 2007. A un grupo se le practicó una hernioplastia anterior con malla y al otro la técnica de Mohan P. Desarda, la cual consiste en una herniorrafia sin malla. RESULTADOS. Ambos grupos de pacientes fueron comparables, sin diferencias con respecto a la edad, la localización y el tipo de hernia. El tiempo quirúrgico fue menor en la hernioplastia con malla y no hubo diferencias significativas en cuanto al dolor durante el primer y tercer día del posoperatorio, pero en el grupo de la hernioplastia éste fue superior al quinto día. En tres pacientes hubo rechazo a la malla de polipropileno. CONCLUSIONES. La técnica de Desarda, al no utilizar malla, fue más económica que la hernioplastia con malla; esta diferencia fue estadísticamente significativa.INTRODUCTION: With present paper we gave response to some controversies around the repair of inguinal hernias as well as to make a valuation on postoperative pain and to analyze the costs of prosthetic repair techniques and the technique reinforcing the posterior wall of inguinal channel with a pediculate aponeurotic band of major obliquus muscle. METHODS: A random prospective study was conducted in 836 patients presenting with inguinal hernia, operated on between September, 2001 and December, 2007. A group underwent anterior hernioplasty with mesh and in the other we used Mohan P. Desarda technique, which is a herniorrhaphy without mesh. RESULTS: Both groups

  13. Iliohypogastric/ilioinguinal nerve block in inguinal hernia repair for postoperative pain management: comparison of the anatomical landmark and ultrasound guided techniques

    Directory of Open Access Journals (Sweden)

    Abdurrahman Demirci

    2014-10-01

    Full Text Available Objectives:The purpose of this study is to compare the efficacy of iliohypogastric/ilioinguinal nerve blocks performed with the ultrasound guided and the anatomical landmark techniques for postoperative pain management in cases of adult inguinal herniorrhaphy.Methods:40 patients, ASA I-II status were randomized into two groups equally: in Group AN (anatomical landmark technique and in Group ultrasound (ultrasound guided technique, iliohypogastric/ilioinguinal nerve block was performed with 20 ml of 0.5% levobupivacaine prior to surgery with the specified techniques. Pain score in postoperative assessment, first mobilization time, duration of hospital stay, score of postoperative analgesia satisfaction, opioid induced side effects and complications related to block were assessed for 24 h postoperatively.Results:VAS scores at rest in the recovery room and all the clinical follow-up points were found significantly less in Group ultrasound (p < 0.01 or p < 0.001. VAS scores at movement in the recovery room and all the clinical follow-up points were found significantly less in Group ultrasound (p < 0.001 in all time points. While duration of hospital stay and the first mobilization time were being found significantly shorter, analgesia satisfaction scores were found significantly higher in ultrasound Group (p < 0.05, p < 0.001, p < 0.001 respectively.Conclusion:According to our study, US guided iliohypogastric/ilioinguinal nerve block in adult inguinal herniorrhaphies provides a more effective analgesia and higher satisfaction of analgesia than iliohypogastric/ilioinguinal nerve block with the anatomical landmark technique. Moreover, it may be suggested that the observation of anatomical structures with the US may increase the success of the block, and minimize the block-related complications.

  14. Adaptive regenerative braking for electric vehicles with an electric motor at the front axle using the state dependent Riccati equation control technique

    NARCIS (Netherlands)

    Jansen, S.; Alirezaei, M.; Kanarachos, S.

    2014-01-01

    In this paper a novel adaptive regenerative braking control concept for electric vehicles with an electric motor at the front axle is presented. It is well known that the "phased" type regenerative braking systems of category B maximize the amount of regenerative energy during braking. However,

  15. The use of a special software for induction motor diagnostics in the diamond industry

    Directory of Open Access Journals (Sweden)

    Shevchuk Vladislav A.

    2017-01-01

    Full Text Available The field of induction motor application in the diamond industry has considerably increased due to the transition to the underground mining method. This article is devoted to the research the induction motor diagnostic technique in the diamond industry using special software. The practice shows that unreliability of induction motors causes some serious economic losses related to the expenses on premature maintenance and idle time. This article is devoted to the research of diagnostic technique of induction motors in the diamond industry using a special software. The article presents some data obtained in the course of the research conducted at an industrial site of the diamond company “ALROSA” in Mirny using the vibration-based diagnostics. Thus, based on the analysis of the findings some recommendations concerning the improvement of maintenance and servicing system have been given. The use of these recommendations allows assessing the operational reliability of induction motors in the diamond industry, minimizing the risk of sudden failures and reducing the maintenance and repair expenses.

  16. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs

    OpenAIRE

    Dorweiler, Matthew A.; Van Dyke, Rufus O.; Siska, Robert C.; Boin, Michael A.; DiPaola, Mathew J.

    2017-01-01

    Background: Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. Hypothesis: The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Study Design: Controlled laboratory study. Methods: Eighteen ca...

  17. Concepts of nerve regeneration and repair applied to brachial plexus reconstruction.

    Science.gov (United States)

    Bertelli, Jayme Augusto; Ghizoni, Marcos Flávio

    2006-01-01

    Brachial plexus injury is a serious condition that usually affects young adults. Progress in brachial plexus repair is intimately related to peripheral nerve surgery, and depends on clinical and experimental studies. We review the rat brachial plexus as an experimental model, together with its behavioral evaluation. Techniques to repair nerves, such as neurolysis, nerve coaptation, nerve grafting, nerve transfer, fascicular transfer, direct muscle neurotization, and end-to-side neurorraphy, are discussed in light of the authors' experimental studies. Intradural repair of the brachial plexus by graft implants into the spinal cord and motor rootlet transfer offer new possibilities in brachial plexus reconstruction. The clinical experience of intradural repair is presented. Surgical planning in root rupture or avulsion is proposed. In total avulsion, the authors are in favor of the reconstruction of thoraco-brachial and abdomino-antebrachial grasping, and on the transfer of the brachialis muscle to the wrist extensors if it is reinnervated. Surgical treatment of painful conditions and new drugs are also discussed.

  18. Switched reluctance motor drives

    Indian Academy of Sciences (India)

    Davis RM, Ray WF, Blake RJ 1981 Inverter drive for switched reluctance: circuits and component ratings. Inst. Elec. Eng. Proc. B128: 126-136. Ehsani M. 1991 Position Sensor elimination technique for the switched reluctance motor drive. US Patent No. 5,072,166. Ehsani M, Ramani K R 1993 Direct control strategies based ...

  19. Anomalia de Ebstein em paciente adulto: valvuloplastia modificada para correção de insuficiência tricúspide Ebstein's anomaly in adult patients: modified repair technique for tricuspid insufficiency

    Directory of Open Access Journals (Sweden)

    Mauro Barbosa ARRUDA FILHO

    2002-06-01

    Full Text Available OBJETIVOS: Avaliar a correção cirúrgica em pacientes adultos portadores de anomalia de Ebstein, utilizando uma variação técnica para correção da insuficiência tricúspide. CASUÍSTICA E MÉTODOS: Entre janeiro de 1990 e março de 2001, seis pacientes adultos foram submetidos à correção cirúrgica com uma variação da técnica apresentada por Carpentier. A idade variou de 18 a 34 anos. Todos se apresentavam em classe funcional III ou IV (NYHA, com piora da cianose ou arritmias freqüentes. Em quatro pacientes a valva tricúspide era do tipo B e em dois do tipo A (Carpentier, quatro apresentavam comunicação interatrial (CIA associada. O hematócrito variou de 33% a 68%. O índice cardíaco variou de 0.47 a 0.88. A fração de ejeção do ventrículo esquerdo variou de 50% a 80%. RESULTADOS: Não se registrou óbitos no período hospitalar. Um paciente foi reoperado por sangramento no pós-operatório imediato. Em dois pacientes ocorreram derrames pericárdicos de repetição. Foi registrado um óbito no 14º mês de pós-operatório por morte súbita. Os pacientes foram seguidos por um período de 10 a 108 meses. Quatro encontram-se em classe funcional I e um encontra-se em classe funcional II (NYHA. O ecocardiograma no pós-operatório imediato e na última avaliação mostra insuficiência tricúspide discreta ou moderada em quatro e importante em um paciente. CONCLUSÃO: Apesar do pequeno número de pacientes nesta série, a modificação técnica cumpriu o seu papel, com a melhora clínica e funcional dos pacientes tratados em até nove anos de seguimento.PURPOSE: To value the surgical treatment of adult patients with Ebstein's anomaly, using a Carpentier's modified repair technique. MATERIAL AND METHODS: Between January 1990 and March 2001 six adult patients with Ebstein's anomaly were treated using a modification of Carpentier's repair technique, four were males and two were females, ages ranging from 18 to 34 years (Mean 23

  20. Rapid road repair vehicle

    Science.gov (United States)

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  1. Fault diagnosis of induction motors

    CERN Document Server

    Faiz, Jawad; Joksimović, Gojko

    2017-01-01

    This book is a comprehensive, structural approach to fault diagnosis strategy. The different fault types, signal processing techniques, and loss characterisation are addressed in the book. This is essential reading for work with induction motors for transportation and energy.

  2. Motor homopolar

    OpenAIRE

    Martín Muñoz, Agustín

    2007-01-01

    Mostramos la construcción de un modelo de motor homopolar, uno de los más antiguos tipos de motores eléctricos. Se caracterizan porque el campo magnético del imán mantiene siempre la misma polaridad (de ahí su nombre, del griego homos, igual), de modo que, cuando una corriente eléctrica atraviesa el campo magnético, aparece una fuerza que hace girar los elementos no fijados mecánicamente. En el sencillísimo motor homopolar colgado (Schlichting y Ucke 2004), el imán puede girar ...

  3. A novel conduit-based coaptation device for primary nerve repair.

    Science.gov (United States)

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  4. Applications of bioactive material from snakehead fish (Channa striata) for repairing of learning-memory capability and motoric activity: a case study of physiological aging and aging-caused oxidative stress in rats

    Science.gov (United States)

    Sunarno, Sunarno; Muflichatun Mardiati, Siti; Rahadian, Rully

    2018-05-01

    Physiological aging and aging due to oxidative stress are a major factor cause accelerated brain aging. Aging is characterized by a decrease of brain function of the hippocampus which is linked to the decline in the capability of learning-memory and motoric activity. The objective of this research is to obtain the important information about the mechanisms of brain antiaging associated with the improvement of hippocampus function, which includes aspects of learning-memory capability and motoric activity as well as mitochondrial ultrastructure profile of hippocampus cornu ammonis cells after treated by fish snakehead fish extract. Snakehead fish in Rawa Pening Semarang District allegedly holds the potential of endemic, which contains bioactive antiaging material that can prevent aging or improve the function of the hippocampus. This research has been conducted using a completely randomized design consisting of four treatments with five replications. The treatments were including rats with physiological aging or aging due to oxidative stress which was treated and without treated with meat extract of snakehead fish. The research was divided into two stages, i.e., determining of learning-memory capability, and determining motoric activity. The measured-parameters are time response to find feed, distance travel, time stereotypes, ambulatory time, and resting time. The result showed that the snakehead fish meat extract might improve function hippocampus, both in physiological aging or aging due to oxidative stress. The capability of learning and memory showed that the rats in both conditions of aging after getting treatment of meat extract of snakehead fish could get a feed in the fourth arm maze faster than rats untreated snakehead fish meat extract. Similarly, the measurement of the distance traveled, time stereotypes, ambulatory time, and resting time showed that rats which received treatment of meat extract of snakehead fish were better than the untreated rats. To

  5. Electric Motor Thermal Management R&D

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, Kevin

    2016-06-07

    Thermal management enables more efficient and cost-effective motors. This Annual Merit Review presentation describes the technical accomplishments and progress in electric motor thermal management R&D over the last year. This project supports a broad industry demand for data, analysis methods, and experimental techniques to improve and better understand motor thermal management.

  6. Analysis for a two-dissimilar-component cold standby repairable system with repair priority

    International Nuclear Information System (INIS)

    Leung, Kit Nam Francis; Zhang Yuanlin; Lai, Kin Keung

    2011-01-01

    In this paper, a cold standby repairable system consisting of two dissimilar components and one repairman is studied. Assume that working time distributions and repair time distributions of the two components are both exponential, and Component 1 has repair priority when both components are broken down. After repair, Component 1 follows a geometric process repair while Component 2 obeys a perfect repair. Under these assumptions, using the perfect repair model, the geometric process repair model and the supplementary variable technique, we not only study some important reliability indices, but also consider a replacement policy T, under which the system is replaced when the working age of Component 1 reaches T. Our problem is to determine an optimal policy T* such that the long-run average loss per unit time (i.e. average loss rate) of the system is minimized. The explicit expression for the average loss rate of the system is derived, and the corresponding optimal replacement policy T* can be found numerically. Finally, a numerical example for replacement policy T is given to illustrate some theoretical results and the model's applicability. - Highlights: → A two-dissimilar-component cold standby system with repair priority is formulated. → The successive up/repair times of Component 1 form a decreasing/increasing geometric process. → Not only some reliability indices but also a replacement policy are studied.

  7. Assessment of capacity building needs among motor vehicle ...

    African Journals Online (AJOL)

    The motor vehicle mechanics trainers' are affected by the developments in the modern automobile technology (MAT) that brought about the use of auto scan tools for diagnosis and repair of modern vehicles in Nigeria. This study examined the capacity building needs among motor vehicle mechanics trainers in the use of ...

  8. Application of stepping motor

    International Nuclear Information System (INIS)

    1980-10-01

    This book is divided into three parts, which is about practical using of stepping motor. The first part has six chapters. The contents of the first part are about stepping motor, classification of stepping motor, basic theory og stepping motor, characteristic and basic words, types and characteristic of stepping motor in hybrid type and basic control of stepping motor. The second part deals with application of stepping motor with hardware of stepping motor control, stepping motor control by microcomputer and software of stepping motor control. The last part mentions choice of stepping motor system, examples of stepping motor, measurement of stepping motor and practical cases of application of stepping motor.

  9. Saturation of DNA repair in mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, F E; Setlow, R B

    1979-01-01

    Excision repair seems to reach a plateau in normal human cells at a 254 nm dose near 20 J/m/sup 2/. We measured excision repair in normal human fibroblasts up to 80 J/m/sup 2/. The four techniques used (unscheduled DNA synthesis, photolysis of BrdUrd incorporated during repair, loss of sites sensitive to a UV endonuclease from Micrococcus luteus, and loss of pyrimidine dimers from DNA) showed little difference between the two doses. Moreover, the loss of endonuclease sites in 24h following two 20 J/m/sup 2/ doses separated by 24h was similar to the loss observed following one dose. Hence, we concluded that the observed plateau in excision repair is real and does not represent some inhibitory process at high doses but a true saturation of one of the rate limiting steps in repair.

  10. Male Fertility After Inguinal Hernia Mesh Repair

    DEFF Research Database (Denmark)

    Kohl, Andreas Pagh; Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    OBJECTIVE:: To determine whether patients who receive an inguinal hernia repair father the same number of children as the background population. BACKGROUND:: Although the effect of inguinal hernia repair on male fertility has previously been investigated through indirect measures, no previous...... studies have evaluated the final measure of male fertility, which is the number of children fathered by patients. METHODS:: Prospectively collected data on 32,621 male patients between the ages of 18 and 55 years who received 1 or more inguinal hernia repairs during the years 1998 to 2012 were found in 5...... hernia repair using Lichtenstein technique or laparoscopic approach did not father fewer children than expected. Thus, inguinal hernia repair using Lichtenstein or laparoscopic approach did not impair male fertility....

  11. Iliohypogastric/ilioinguinal nerve block in inguinal hernia repair for postoperative pain management: comparison of the anatomical landmark and ultrasound guided techniques

    Directory of Open Access Journals (Sweden)

    Abdurrahman Demirci

    2014-09-01

    Full Text Available Objectives: The purpose of this study is to compare the efficacy of iliohypogastric/ilioinguinal nerve blocks performed with the ultrasound guided and the anatomical landmark techniques for postoperative pain management in cases of adult inguinal herniorrhaphy. Methods: 40 patients, ASA I–II status were randomized into two groups equally: in Group AN (anatomical landmark technique and in Group ultrasound (ultrasound guided technique, iliohypogastric/ilioinguinal nerve block was performed with 20 ml of 0.5% levobupivacaine prior to surgery with the specified techniques. Pain score in postoperative assessment, first mobilization time, duration of hospital stay, score of postoperative analgesia satisfaction, opioid induced side effects and complications related to block were assessed for 24 h postoperatively. Results: VAS scores at rest in the recovery room and all the clinical follow-up points were found significantly less in Group ultrasound (p < 0.01 or p < 0.001. VAS scores at movement in the recovery room and all the clinical follow-up points were found significantly less in Group ultrasound (p < 0.001 in all time points. While duration of hospital stay and the first mobilization time were being found significantly shorter, analgesia satisfaction scores were found significantly higher in ultrasound Group (p < 0.05, p < 0.001, p < 0.001 respectively. Conclusion: According to our study, US guided iliohypogastric/ilioinguinal nerve block in adult inguinal herniorrhaphies provides a more effective analgesia and higher satisfaction of analgesia than iliohypogastric/ilioinguinal nerve block with the anatomical landmark technique. Moreover, it may be suggested that the observation of anatomical structures with the US may increase the success of the block, and minimize the block-related complications. Resumo: Objetivo: Comparar a eficácia de bloqueios dos nervos ílio-hipogástrico/ilioinguinal feitos com a técnica guiada por

  12. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  13. Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign targets meaningful risk reduction in the Collision Repair source category to reduce air toxic emissions in their communities. The Campaign also helps shops to work towards early compliance with the Auto Body Rule.

  14. Retinal detachment repair

    Science.gov (United States)

    ... medicines Problems breathing You may not recover full vision. ... detachments can be repaired. Failure to repair the retina always results in loss of vision to some degree. After surgery, the quality of ...

  15. Visceral hybrid reconstruction of thoracoabdominal aortic aneurysm after open repair of type a aortic dissection by the Bentall procedure with the elephant trunk technique: A case report

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2014-01-01

    Full Text Available Introduction. Reconstruction of chronic type B dissection and thoracoabdominal aortic aneurysm (TAAA remaining after the emergency reconstruction of the ascending thoracic aorta and aortic arch for acute type A dissection represents one of the major surgical challenges. Complications of chronic type B dissection are aneurysmal formation and rupture of an aortic aneurysm with a high mortality rate. We presented a case of visceral hybrid reconstruction of TAAA secondary to chronic dissection type B after the Bentall procedure with the elephant trunk technique due to acute type A aortic dissection in a high-risk patient. Case report. A 62 year-old woman was admitted to our institution for reconstruction of Crawford type I TAAA secondary to chronic dissection. The patient had had an acute type A aortic dissection 3 years before and undergone reconstruction by the Bentall procedure with the elephant trunk technique with valve replacement. On admission the patient had coronary artery disease (myocardial infarction, two times in the past 3 years, congestive heart disease with ejection fraction of 25% and chronic obstructive pulmonary disease. On computed tomography (CT of the aorta TAAA was revealed with a maximum diameter of 93 mm in the descending thoracic aorta secondary to chronic dissection. All the visceral arteries originated from the true lumen with exception of the celiac artery (CA, and the end of chronic dissection was below the origin of the superior mesenteric artery (SMA. The patient was operated on using surgical visceral reconstruction of the SMA, CA and the right renal artery (RRA as the first procedure. Postoperative course was without complications. Endovascular TAAA reconstruction was performed as the second procedure one month later, when the elephant trunk was used as the proximal landing zone for the endograft, and distal landing zone was the level of origin of the RRA. Postoperatively, the patient had no neurological deficit and

  16. Primary unilateral cleft lip repair.

    Science.gov (United States)

    Adenwalla, H S; Narayanan, P V

    2009-10-01

    The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  17. Primary unilateral cleft lip repair

    Directory of Open Access Journals (Sweden)

    Adenwalla H

    2009-10-01

    Full Text Available The unilateral cleft lip is a complex deformity. Surgical correction has evolved from a straight repair through triangular and quadrilateral repairs to the Rotation Advancement Technique of Millard. The latter is the technique followed at our centre for all unilateral cleft lip patients. We operate on these at five to six months of age, do not use pre-surgical orthodontics, and follow a protocol to produce a notch-free vermillion. This is easy to follow even for trainees. We also perform closed alar dissection and extensive primary septoplasty in all these patients. This has improved the overall result and has no long-term deleterious effect on the growth of the nose or of the maxilla. Other refinements have been used for prevention of a high-riding nostril, and correction of the vestibular web.

  18. Advancing research in regeneration and repair of the motor circuitry: non-human primate models and imaging scales as the missing links for successfully translating injectable therapeutics to the clinic.

    Science.gov (United States)

    Tsintou, Magdalini; Dalamagkas, Kyriakos; Makris, Nikos

    2016-01-01

    Regeneration and repair is the ultimate goal of therapeutics in trauma of the central nervous system (CNS). Stroke and spinal cord injury (SCI) are two highly prevalent CNS disorders that remain incurable, despite numerous research studies and the clinical need for effective treatments. Neural engineering is a diverse biomedical field, that addresses these diseases using new approaches. Research in the field involves principally rodent models and biologically active, biodegradable hydrogels. Promising results have been reported in preclinical studies of CNS repair, demonstrating the great potential for the development of new treatments for the brain, spinal cord and peripheral nerve injury. Several obstacles stand in the way of clinical translation of neuroregeneration research. There seems to be a key gap in the translation of research from rodent models to human applications, namely non-human primate models, which constitute a critical bridging step. Applying injectable therapeutics and multimodal neuroimaging in stroke lesions using experimental rhesus monkey models is an avenue that a few research groups have begun to embark on. Understanding and assessing the changes that the injured brain or spinal cord undergoes after an intervention with biodegradable hydrogels in non-human primates seem to represent critical preclinical research steps. Existing innovative models in non-human primates allow us to evaluate the potential of neural engineering and injectable hydrogels. The results of these preliminary studies will pave the way for translating this research into much needed clinical therapeutic approaches. Cutting edge imaging technology using Connectome scanners represents a tremendous advancement, enabling the in vivo, detailed, high-resolution evaluation of these therapeutic interventions in experimental animals. Most importantly, they also allow quantifiable and clinically meaningful correlations with humans, increasing the translatability of these

  19. Weld Repair of Thin Aluminum Sheet

    Science.gov (United States)

    Beuyukian, C. S.; Mitchell, M. J.

    1986-01-01

    Weld repairing of thin aluminum sheets now possible, using niobium shield and copper heat sinks. Refractory niobium shield protects aluminum adjacent to hole, while copper heat sinks help conduct heat away from repair site. Technique limits tungsten/inert-gas (TIG) welding bombardment zone to melt area, leaving surrounding areas around weld unaffected. Used successfully to repair aluminum cold plates on Space Shuttle, Commercial applications, especially in sealing fractures, dents, and holes in thin aluminum face sheets or clad brazing sheet in cold plates, heat exchangers, coolers, and Solar panels. While particularly suited to thin aluminum sheet, this process also used in thicker aluminum material to prevent surface damage near weld area.

  20. Advanced repair methods for enhanced reactor safety

    International Nuclear Information System (INIS)

    Kornfeldt, H.

    1993-01-01

    A few innovative concepts are described of the ABB Atom Service Division for repair and mitigation techniques for primary systems in nuclear power plants. The concepts are based on Shape Memory Alloy (SMA) technology. A basic feature of all methods is that welding and component replacement is being avoided and the radiation dose imposed on maintenance personnel reduced. The SMA-based repair methods give plant operators new ways to meet increased safety standards and rising maintenance costs. (Z.S.) 4 figs

  1. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.

    Science.gov (United States)

    Maddox, Grady E; Ludwig, Jonathan; Craig, Eric R; Woods, David; Joiner, Aaron; Chaudhari, Nilesh; Killingsworth, Cheryl; Siegal, Gene P; Eberhardt, Alan; Ponce, Brent

    2015-05-01

    To compare and analyze biomechanical properties and histological characteristics of flexor tendons either repaired by a 4-strand modified Kessler technique or using barbed suture with a knotless repair technique in an in vivo model. A total of 25 chickens underwent surgical transection of the flexor digitorum profundus tendon followed by either a 4-strand Kessler repair or a knotless repair with barbed suture. Chickens were randomly assigned to 1 of 3 groups with various postoperative times to death. Harvested tendons were subjected to biomechanical testing or histologic analysis. Harvested tendons revealed failures in 25% of knotless repairs (8 of 32) and 8% of 4-strand Kessler repairs (2 of 24). Biomechanical testing revealed no significant difference in tensile strength between 4-strand Kessler and barbed repairs; however, this lack of difference may be attributed to lower statistical power. We noted a trend toward a gradual decrease in strength over time for barbed repairs, whereas we noticed the opposite for the 4-strand Kessler repairs. Mode of failure during testing differed between repair types. The barbed repairs tended toward suture breakage as opposed to 4-strand Kessler repairs, which demonstrated suture pullout. Histological analysis identified no difference in the degree of inflammation or fibrosis; however, there was a vigorous foreign body reaction around the 4-strand Kessler repair and no such response around the barbed repairs. In this model, knotless barbed repairs trended toward higher in vivo failure rates and biomechanical inferiority under physiologic conditions, with each repair technique differing in mode of failure and respective histologic reaction. We are unable to recommend the use of knotless barbed repair over the 4-strand modified Kessler technique. For the repair techniques tested, surgeons should prefer standard Kessler repairs over the described knotless technique with barbed suture. Copyright © 2015 American Society for Surgery

  2. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    Background For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. Data sources...... A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  3. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    BACKGROUND: For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. DATA SOURCES......: A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  4. Leak testing and repair of fusion devices

    International Nuclear Information System (INIS)

    Kozman, T.A.

    1983-01-01

    The leak testing, reporting and vacuum leak repair techniques of the MFTF yin-yang number one magnet system, the world's largest superconducting magnet system, are discussed. Based on this experience, techniques will be developed for testing and repairing leaks on the 42 MFTF-B magnets. The leak-hunting techniques for the yin-yang magnet systems were applied to two helium circuits (the coil bundle and guard vacuum; both require helium flow for magnet cooldown), their associated piping, liquid nitrogen radiation shields, and piping. Additionally, during MFTF-B operation there will be warm water plasma shields and piping that require leak checking

  5. The forked flap repair for hypospadias

    Directory of Open Access Journals (Sweden)

    Anil Chadha

    2012-01-01

    Full Text Available Context: Despite the abundance of techniques for the repair of Hypospadias, its problems still persist and a satisfactory design to correct the penile curvature with the formation of neourethra from the native urethral tissue or genital or extragenital tissues, with minimal postoperative complications has yet to evolve. Aim: Persisting with such an endeavor, a new technique for the repair of distal and midpenile hypospadias is described. Materials and Methods: The study has been done in 70 cases over the past 11 years. The "Forked-Flap" repair is a single stage method for the repair of such Hypospadias with chordee. It takes advantage of the rich vascular communication at the corona and capitalizes on the established reliability of the meatal based flip-flap. The repair achieves straightening of the curvature of the penis by complete excision of chordee tissue from the ventral surface of the penis beneath the urethral plate. The urethra is reconstructed using the native plate with forked flap extensions and genital tissue relying on the concept of meatal based flaps. Water proofing by dartos tissue and reinforcement by Nesbit′s prepucial tissue transfer completes the one stage procedure. Statistical Analysis: An analysis of 70 cases of this single stage technique of repair of penile hypospadias with chordee, operated at 3 to 5 years of age over the past 11 years is presented. Results and Conclusion: The Forked Flap gives comparable and replicable results; except for a urethrocutaneous fistula rate of 4% no other complications were observed.

  6. Low cost electronic ultracapacitor interface technique to provide load leveling of a battery for pulsed load or motor traction drive applications

    Science.gov (United States)

    King, Robert Dean; DeDoncker, Rik Wivina Anna Adelson

    1998-01-01

    A battery load leveling arrangement for an electrically powered system in which battery loading is subject to intermittent high current loading utilizes a passive energy storage device and a diode connected in series with the storage device to conduct current from the storage device to the load when current demand forces a drop in battery voltage. A current limiting circuit is connected in parallel with the diode for recharging the passive energy storage device. The current limiting circuit functions to limit the average magnitude of recharge current supplied to the storage device. Various forms of current limiting circuits are disclosed, including a PTC resistor coupled in parallel with a fixed resistor. The current limit circuit may also include an SCR for switching regenerative braking current to the device when the system is connected to power an electric motor.

  7. Content-Related Repairing of Inconsistencies in Distributed Data

    Institute of Scientific and Technical Information of China (English)

    Yue-Feng Du; De-Rong Shen; Tie-Zheng Nie; Yue Kou; Ge Yu

    2016-01-01

    Conditional functional dependencies (CFDs) are a critical technique for detecting inconsistencies while they may ignore some potential inconsistencies without considering the content relationship of data. Content-related conditional functional dependencies (CCFDs) are a type of special CFDs, which combine content-related CFDs and detect potential inconsistencies by putting content-related data together. In the process of cleaning inconsistencies, detection and repairing are interactive: 1) detection catches inconsistencies, 2) repairing corrects caught inconsistencies while may bring new incon-sistencies. Besides, data are often fragmented and distributed into multiple sites. It consequently costs expensive shipment for inconsistencies cleaning. In this paper, our aim is to repair inconsistencies in distributed content-related data. We propose a framework consisting of an inconsistencies detection method and an inconsistencies repairing method, which work iteratively. The detection method marks the violated CCFDs for computing the inconsistencies which should be repaired preferentially. Based on the repairing-cost model presented in this paper, we prove that the minimum-cost repairing using CCFDs is NP-complete. Therefore, the repairing method heuristically repairs the inconsistencies with minimum cost. To improve the efficiency and accuracy of repairing, we propose distinct values and rules sequences. Distinct values make less data shipments than real data for communication. Rules sequences determine appropriate repairing sequences to avoid some incorrect repairs. Our solution is proved to be more effective than CFDs by empirical evaluation on two real-life datasets.

  8. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time-efficien......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time...

  9. How to make spinal motor neurons.

    Science.gov (United States)

    Davis-Dusenbery, Brandi N; Williams, Luis A; Klim, Joseph R; Eggan, Kevin

    2014-02-01

    All muscle movements, including breathing, walking, and fine motor skills rely on the function of the spinal motor neuron to transmit signals from the brain to individual muscle groups. Loss of spinal motor neuron function underlies several neurological disorders for which treatment has been hampered by the inability to obtain sufficient quantities of primary motor neurons to perform mechanistic studies or drug screens. Progress towards overcoming this challenge has been achieved through the synthesis of developmental biology paradigms and advances in stem cell and reprogramming technology, which allow the production of motor neurons in vitro. In this Primer, we discuss how the logic of spinal motor neuron development has been applied to allow generation of motor neurons either from pluripotent stem cells by directed differentiation and transcriptional programming, or from somatic cells by direct lineage conversion. Finally, we discuss methods to evaluate the molecular and functional properties of motor neurons generated through each of these techniques.

  10. How Kinesthetic Motor Imagery works: A predictive-processing theory of visualization in sports and motor expertise

    NARCIS (Netherlands)

    Ridderinkhof, K.R.; Brass, M.

    2015-01-01

    Kinesthetic Motor Imagery (KMI) is an important technique to acquire and refine motor skills. KMI is widely used by professional athletes as an effective way to improve motor performance without overt motor output. Despite this obvious relevance, the functional mechanisms and neural circuits

  11. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  12. Shouldice Versus Lichtenstein Hernia Repair Techniques: A ...

    African Journals Online (AJOL)

    inguinal hernia surgery and to determine to what extent doctors in ... The inclusion criteria was men between 18 ... length and a minimal amount of purulent material expressed ... examination and personal interview; done by the ... *Values are mean (standard deviation). ... a shorter time, reflecting the ease of the operation is.

  13. Ontology Alignment Repair through Modularization and Confidence-Based Heuristics.

    Directory of Open Access Journals (Sweden)

    Emanuel Santos

    Full Text Available Ontology Matching aims at identifying a set of semantic correspondences, called an alignment, between related ontologies. In recent years, there has been a growing interest in efficient and effective matching methods for large ontologies. However, alignments produced for large ontologies are often logically incoherent. It was only recently that the use of repair techniques to improve the coherence of ontology alignments began to be explored. This paper presents a novel modularization technique for ontology alignment repair which extracts fragments of the input ontologies that only contain the necessary classes and relations to resolve all detectable incoherences. The paper presents also an alignment repair algorithm that uses a global repair strategy to minimize both the degree of incoherence and the number of mappings removed from the alignment, while overcoming the scalability problem by employing the proposed modularization technique. Our evaluation shows that our modularization technique produces significantly small fragments of the ontologies and that our repair algorithm produces more complete alignments than other current alignment repair systems, while obtaining an equivalent degree of incoherence. Additionally, we also present a variant of our repair algorithm that makes use of the confidence values of the mappings to improve alignment repair. Our repair algorithm was implemented as part of AgreementMakerLight, a free and open-source ontology matching system.

  14. Ontology Alignment Repair through Modularization and Confidence-Based Heuristics.

    Science.gov (United States)

    Santos, Emanuel; Faria, Daniel; Pesquita, Catia; Couto, Francisco M

    2015-01-01

    Ontology Matching aims at identifying a set of semantic correspondences, called an alignment, between related ontologies. In recent years, there has been a growing interest in efficient and effective matching methods for large ontologies. However, alignments produced for large ontologies are often logically incoherent. It was only recently that the use of repair techniques to improve the coherence of ontology alignments began to be explored. This paper presents a novel modularization technique for ontology alignment repair which extracts fragments of the input ontologies that only contain the necessary classes and relations to resolve all detectable incoherences. The paper presents also an alignment repair algorithm that uses a global repair strategy to minimize both the degree of incoherence and the number of mappings removed from the alignment, while overcoming the scalability problem by employing the proposed modularization technique. Our evaluation shows that our modularization technique produces significantly small fragments of the ontologies and that our repair algorithm produces more complete alignments than other current alignment repair systems, while obtaining an equivalent degree of incoherence. Additionally, we also present a variant of our repair algorithm that makes use of the confidence values of the mappings to improve alignment repair. Our repair algorithm was implemented as part of AgreementMakerLight, a free and open-source ontology matching system.

  15. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  16. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence.

    Science.gov (United States)

    Wall, Lindley B; Keener, Jay D; Brophy, Robert H

    2009-01-01

    A review of the current literature will show a difference between the biomechanical properties of double-row and single-row rotator cuff repairs. Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. We reviewed the literature of all biomechanical studies comparing double-row vs single-row repair techniques. Inclusion criteria included studies using cadaveric, animal, or human models that directly compared double-row vs single-row repair techniques, written in the English language, and published in peer reviewed journals. Identified articles were reviewed to provide a comprehensive conclusion of the biomechanical strength and integrity of the repair techniques. Fifteen studies were identified and reviewed. Nine studies showed a statistically significant advantage to a double-row repair with regards to biomechanical strength, failure, and gap formation. Three studies produced results that did not show any statistical advantage. Five studies that directly compared footprint reconstruction all demonstrated that the double-row repair was superior to a single-row repair in restoring anatomy. The current literature reveals that the biomechanical properties of a double-row rotator cuff repair are superior to a single-row repair. Basic Science Study, SRH = Single vs. Double Row RCR.

  17. An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.

    Science.gov (United States)

    Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P

    2017-11-01

    Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior

  18. 'Regular' and 'emergency' repair

    International Nuclear Information System (INIS)

    Luchnik, N.V.

    1975-01-01

    Experiments on the combined action of radiation and a DNA inhibitor using Crepis roots and on split-dose irradiation of human lymphocytes lead to the conclusion that there are two types of repair. The 'regular' repair takes place twice in each mitotic cycle and ensures the maintenance of genetic stability. The 'emergency' repair is induced at all stages of the mitotic cycle by high levels of injury. (author)

  19. Repair kinetics in tissues

    International Nuclear Information System (INIS)

    Thames, H.D.

    1989-01-01

    Monoexponential repair kinetics is based on the assumption of a single, dose-independent rate of repair of sublethal injury in the target cells for tissue injury after exposure to ionizing radiation. Descriptions of the available data based on this assumption have proved fairly successful for both acutely responding (skin, lip mucosa, gut) and late-responding (lung, spinal cord) normal tissues. There are indications of biphasic exponential repair in both categories, however. Unfortunately, the data usually lack sufficient resolution to permit unambiguous determination of the repair rates. There are also indications that repair kinetics may depend on the size of the dose. The data are conflicting on this account, however, with suggestions of both faster and slower repair after larger doses. Indeed, experiments that have been explicitly designed to test this hypothesis show either no effect (gut, spinal cord), faster repair after higher doses (lung, kidney), or slower repair after higher doses (skin). Monoexponential repair appears to be a fairly accurate description that provides an approximation to a more complicated picture, the elucidation of whose details will, however, require very careful and extensive experimental study. (author). 30 refs.; 1 fig

  20. Radiation repair models for clinical application.

    Science.gov (United States)

    Dale, Roger G

    2018-02-28

    A number of newly emerging clinical techniques involve non-conventional patterns of radiation delivery which require an appreciation of the role played by radiation repair phenomena. This review outlines the main models of radiation repair, focussing on those which are of greatest clinical usefulness and which may be incorporated into biologically effective dose assessments. The need to account for the apparent "slowing-down" of repair rates observed in some normal tissues is also examined, along with a comparison of the relative merits of the formulations which can be used to account for such phenomena. Jack Fowler brought valuable insight to the understanding of radiation repair processes and this article includes reference to his important contributions in this area.

  1. Design of linear pulse motor for control element drive mechanism of SMART

    International Nuclear Information System (INIS)

    Kim, J. H.; Huh, H.; Kim, J. I.; Jang, M. H.; Kang, D. H.

    1999-01-01

    49 Control Rod Drive Mechanisms(CEDMs) are densely installed on the reactor central head of SMART. The structural design should ensure the space for maintenance/repair, cable routing, and heat release from the motor. In this paper, an improved design is presented to enlarge the space between CEDMs by decreasing the diameter of linear pulse motor. The reduction of motor thrust force due to the decrease of the motor diameter is compensated by resizing the other structural components

  2. The Static Eccentricity Fault Diagnosis in Time Domain at Line Start Permanent Magnet Synchronous Motor

    OpenAIRE

    DOGAN, Zafer

    2016-01-01

    Recently, Line Start Permanent Magnet Synchronous Motor have been commonly utilized in industrial areas because of their high efficiency. Motor faults during operation cause losses of production and high maintenance and repair expenditures. In this study, the effect of static eccentricity fault on line start permanent magnet synchronous motor was investigated. The simulation models of motor belonging to healthy and fault status were formed via Finite Elements Method. The analyses in time doma...

  3. Jidosha's Motors

    OpenAIRE

    Shirakawa Okuma, Rosely; Calderón Orejuela, Javier

    2016-01-01

    La tesis narra la situación de una empresa concesionaria de vehículos nuevos, Jidosha's Motors, perteneciente a una corporación japonesa que cuenta con una cultura muy arraigada de ética y de cumplimiento. Se plantean respuestas, se identifican problemas y sus alternativas de solución para una toma adecuada de decisiones por parte de los directivos, siguiendo una estructura de análisis de situaciones de negocios (ASN). Tesis

  4. Perancangan dan Pembuatan Website E-Commerce Mulia Kencana Motor

    OpenAIRE

    Ericko, Stefanus; Dewi, Lily Puspa; Rostianingsih, Silvia

    2015-01-01

    Mulia Kencana Motor is a motorcycle repair shop. It sells spareparts which is located in Yogyakarta. Since it has opened until present, the selling-buying process is done directly, the user come to the seller, Mulia Kencana Motor, then buys the goods or either makes an order. Mulia Kencana Motor need to have an online website that could connect both parties to sell and buy via website, therefore the range area of customer will be expanded.Through website, Mulia Kencana Motor could do an onlin...

  5. X-ray diffraction based residual stress analysis of repair welds of CrMo steels

    International Nuclear Information System (INIS)

    Rai, Sanjay; Sujith, S.; Jayakumar, T.

    1996-01-01

    Premature failure of weldments is often reported in the industry. Once failure occurs, the common practice now a days is either to replace the whole component or repair the failed region by welding. Since repairing rather than replacing is more economical, the process of repair welding assumes technological significance. However, it is necessary to realise the problems associated with repair-welding. During most of the repair welding cases, after repair weldments are hard and brittle. In many cases it is not possible to give post weld heat treatment (PWHT). This demands better welding techniques for repair without affecting the microstructure. Repair welding requires adoption of special procedure and parameters to obtain acceptable properties of the repair welded regions. In this paper different repair welding methods have been compared from residual stress and hardness point of view. (author)

  6. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  7. A comparison of the DNA and chromosome repair kinetics after #betta# irradiation

    International Nuclear Information System (INIS)

    Hittelman, W.N.; Pollard, M.

    1982-01-01

    The kinetics of repair at the chromosome and DNA levels were compared after #betta# irradiation of Chinese hamster ovary cells (CHO). Induction and repair of DNA damage were measured by the alkaline and neutral elution techniques, while chromosome damage and repair were determined by the technique of premature chromosome condensation. During and after #betta# irradiation, significant DNA repair occurred within 2 min. This fast repair could be inhibited by EDTA and pyrophosphate and probably reflected polynucleotide ligase activity. A slower component of DNA repair was detected between 15 and 60 min after irradiation, by which time most of the DNA had been repaired. In contrast, chromosome repair was not detectable until 45 min after irradiation, and nearly half of the chromatid breaks were repaired by 60 min. Cycloheximide, an inhibitor of protein synthesis, prevented chromosome break repair, yet had no effect on the immediate formation of chromatid exchanges or DNA repair. These results suggest the following: (1) the rapidly repairing DNA lesions are not important in the repair of chromosomes; (2) chromosome damage involves only a minority of the DNA lesions measured by alkaline and neutral DNA elution; and (3) chromosome repair may involve more than simply the repair of damaged DNA that can be detected by the alkaline and neutral elution assays

  8. MR imaging of cartilage and its repair in the knee - a review

    International Nuclear Information System (INIS)

    Trattnig, S.; Welsch, G.W.; Domayer, S.; Mosher, T.; Eckstein, F.

    2009-01-01

    Chondral injuries are common lesions of the knee joint, and many patients could benefit from cartilage repair. Widespread cartilage repair techniques require sophisticated noninvasive follow-up using MRI. In addition to the precise morphological assessment of this area of cartilage repair, the cartilage's biochemical constitution can be determined using biochemical MRI techniques. The combination of the clinical outcome after cartilage repair together with the morphological and biochemical description of the cartilage repair tissue as well as the surrounding cartilage can lead to an optimal follow-up evaluation. The present article on MR imaging techniques of cartilage repair focuses on morphological description and scoring using techniques from conventional 2D through advanced isotropic 3D MRI sequences. Furthermore the ultrastructure of the repair tissue and the surrounding cartilage is evaluated in-vivo by biochemical T1-delayed gadolinium enhanced MRI of cartilage (dGEMRIC), T2 relaxation, and diffusion-weighted imaging techniques. (orig.)

  9. Snowmobile Repair. Teacher Edition.

    Science.gov (United States)

    Hennessy, Stephen S.; Conrad, Rex

    This teacher's guide contains 14 units on snowmobile repair: (1) introduction to snowmobile repair; (2) skis, front suspension, and steering; (3) drive clutch; (4) drive belts; (5) driven clutch; (6) chain drives; (7) jackshafts and axles; (8) rear suspension; (9) tracks; (10) shock absorbers; (11) brakes; (12) engines; (13) ignition and…

  10. DNA repair genes

    International Nuclear Information System (INIS)

    Morimyo, Mitsuoki

    1995-01-01

    Fission yeast S. pombe is assumed to be a good model for cloning of human DNA repair genes, because human gene is normally expressed in S. pombe and has a very similar protein sequence to yeast protein. We have tried to elucidate the DNA repair mechanisms of S. pombe as a model system for those of mammals. (J.P.N.)

  11. Behavioral evidence for left-hemisphere specialization of motor planning

    NARCIS (Netherlands)

    Janssen, L.; Meulenbroek, R.G.; Steenbergen, B.

    2011-01-01

    Recent studies suggest that the left hemisphere is dominant for the planning of motor actions. This left-hemisphere specialization hypothesis was proposed in various lines of research, including patient studies, motor imagery studies, and studies involving neurophysiological techniques. However,

  12. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

    LENUS (Irish Health Repository)

    Joyce, C W

    2014-01-01

    We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force was required to create a 2 mm gap in the four-strand repair method compared with the knotless barbed technique. There was a significant reduction in the cross-sectional area in the barbed suture group after repair compared with the Adelaide group. This would create better gliding within the pulley system in vivo and could decrease gapping and tendon rupture.

  13. Semiconductors detectors: basics principals, fabrication and repair

    International Nuclear Information System (INIS)

    Souza Coelho, L.F. de.

    1982-05-01

    The fabrication and repairing techniques of semiconductor detectors, are described. These methods are shown in the way they are applied by the semiconductor detector laboratory of the KFA-Julich, where they have been developed during the last 15 years. The history of the semiconductor detectors is presented here, being also described the detector fabrication experiences inside Brazil. The key problems of manufacturing are raised. In order to understand the fabrication and repairing techniques the working principles of these detectors, are described. The cases in which worked during the stay in the KFA-Julich, particularly the fabrication of a plane Ge (Li) detector, with side entry, and the repair of a coaxial Ge (Li) is described. The vanguard problems being researched in Julich are also described. Finally it is discussed a timetable for the semiconductor detector laboratory of the UFRJ, which laboratory is in the mounting stage now. (Author) [pt

  14. Biomechanical Analysis of an Arthroscopic Broström Ankle Ligament Repair and a Suture Anchor-Augmented Repair.

    Science.gov (United States)

    Giza, Eric; Whitlow, Scott R; Williams, Brady T; Acevedo, Jorge I; Mangone, Peter G; Haytmanek, C Thomas; Curry, Eugene E; Turnbull, Travis Lee; LaPrade, Robert F; Wijdicks, Coen A; Clanton, Thomas O

    2015-07-01

    Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair. © The Author(s) 2015.

  15. Predictable repair of provisional restorations.

    Science.gov (United States)

    Hammond, Barry D; Cooper, Jeril R; Lazarchik, David A

    2009-01-01

    The importance of provisional restorations is often downplayed, as they are thought of by some as only "temporaries." As a result, a less-than-ideal provisional is sometimes fabricated, in part because of the additional chair time required to make provisional modifications when using traditional techniques. Additionally, in many dental practices, these provisional restorations are often fabricated by auxillary personnel who may not be as well trained in the fabrication process. Because provisionals play an important role in achieving the desired final functional and esthetic result, a high-quality provisional restoration is essential to fabricating a successful definitive restoration. This article describes a method for efficiently and predictably repairing both methacrylate and bis-acryl provisional restorations using flowable composite resin. By use of this relatively simple technique, provisional restorations can now be modified or repaired in a timely and productive manner to yield an exceptional result. Successful execution of esthetic and restorative dentistry requires attention to detail in every aspect of the case. Fabrication of high-quality provisional restorations can, at times, be challenging and time consuming. The techniques for optimizing resin provisional restorations as described in this paper are pragmatic and will enhance the delivery of dental treatment.

  16. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    a learning curve of about 50-100 cases and decreases chronic pain, but slightly increases the risk of serious complications compared with open mesh repairs. Therefore, a simpler kind of operation is needed. The ONSTEP technique is a possible solution to this problem. The objective of the present randomised...... comparing the ONSTEP technique with the laparoscopic technique. The results from this study are needed before it can be decided whether the ONSTEP technique should replace the laparoscopic technique in general surgical practice. FUNDING: This study has not received external funding. TRIAL REGISTRATION: NCT...

  17. Use of Several Thermal Analysis Techniques to Study the Cracking of a Nitrile Butadiene Rubber (NBR) Insulator on the Booster Separation Motor (BSM) of the Space Shuttle

    Science.gov (United States)

    Wingard, Charles D.

    1999-01-01

    Two different vendor rubber formulations have been used to produce the silica-filled NBR insulators for the BSM of each of the two Solid Rocket Boosters (SRBs) on the Space Shuttle. Each cured insulator is bonded to the BSM aluminum aft closure with an epoxy adhesive, and some of the curved areas in the rubber may have significant residual stresses. A number of recently bonded NBR insulators have shown fine surface cracks, and stressed insulator areas may be aging at a faster rate than unstressed areas, thus hastening the surface cracking. Thermal analysis data on both vendor insulators by Dynamic Mechanical Analysis (DMA) through a temperature/frequency sweep from 24 to 74 C have shown a higher flexural storage modulus and Arrhenius activation energy for the stressed area than for the unstressed area. Other thermal analysis techniques are being used to study the insulator surface vs. bulk interior for better understanding this anomaly.

  18. Use of Several Thermal Analysis Techniques to Study the Cracking of an Nitrile Butadiene Rubber (NBR) Insulator on the Booster Separation Motor (BSM) of the Space Shuttle

    Science.gov (United States)

    Wingard, Charles D.; Whitaker, Ann F. (Technical Monitor)

    2000-01-01

    Two different vendor rubber formulations have been used to produce the silica-filled NBR insulators for the BSM used on both of the Solid Rocket Boosters (SRBs) of the Space Shuttle. A number of lots of the BSM insulator in 1998-99 exhibited surface cracks and/or crazing. Each insulator is bonded to the BSM aluminum aft closure with an epoxy adhesive. Induced insulator stresses from adhesive cure are likely greatest where the insulator/adhesive contour is the greatest, thus showing increased insulator surface cracking in this area. Thermal analysis testing by Dynamic Mechanical Analyzer (DMA) and Thermomechanical Analysis (TMA) was performed on one each of the two vendor BSM insulators previously bonded that exhibited the surface cracking. The TMA data from the film/fiber technique yielded the most meaningful results, with thin insulator surface samples containing cracks having roughly the same modulus (stiffness) as thin insulator bulk samples just underneath.

  19. Success of Meniscal Repair at ACL Reconstruction

    Science.gov (United States)

    Toman, Charles; Spindler, Kurt P.; Dunn, Warren R.; Amendola, Annunziata; Andrish, Jack T.; Bergfeld, John A.; Flanigan, David; Jones, Morgan; Kaeding, Christopher C.; Marx, Robert G.; Matava, Matthew J.; McCarty, Eric C.; Parker, Richard D.; Wolcott, Michelle; Vidal, Armando; Wolf, Brian R.; Huston, Laura J.; Harrell, Frank E.; Wright, Rick W.

    2013-01-01

    Background Meniscal repair is performed in an attempt to prevent posttraumatic arthritis resulting from meniscal dysfunction after meniscal tears. The socioeconomic implications of premature arthritis are significant in the young patient population. Investigations and techniques focusing on meniscus preservation and healing are now at the forefront of orthopaedic sports medicine. Hypothesis Concomitant meniscal repair with ACL reconstruction is a durable and successful procedure at two year follow-up. Study Design Case Series; Level of evidence, 4. Methods All unilateral primary ACL reconstructions entered in 2002 in a prospective cohort who had meniscal repair at the time of ACLR were evaluated. Validated patient oriented outcome instruments were completed preoperatively and then again at the two-year postoperative time point. Reoperation after the index procedure was also documented and confirmed by operative reports. Results 437 unilateral primary ACL reconstructions were performed with 86 concomitant meniscal repairs (57 medial, 29 lateral) in 84 patients during the study period. Patient follow-up was obtained on 94% (81/86) of the meniscal repairs, allowing confirmation of meniscal repair success (defined as no repeat arthroscopic procedure) or failure. The overall success rate for meniscal repairs was 96% (76/79 patients) at two-year follow-up. Conclusions Meniscal repair is a successful procedure in conjunction with ACL reconstruction. When confronted with a “repairable” meniscal tear at the time of ACL reconstruction, orthopaedic surgeons can expect an estimated >90% clinical success rate at two-year follow-up using a variety of methods as shown in our study. PMID:19465734

  20. Value maximizing maintenance policies under general repair

    International Nuclear Information System (INIS)

    Marais, Karen B.

    2013-01-01

    One class of maintenance optimization problems considers the notion of general repair maintenance policies where systems are repaired or replaced on failure. In each case the optimality is based on minimizing the total maintenance cost of the system. These cost-centric optimizations ignore the value dimension of maintenance and can lead to maintenance strategies that do not maximize system value. This paper applies these ideas to the general repair optimization problem using a semi-Markov decision process, discounted cash flow techniques, and dynamic programming to identify the value-optimal actions for any given time and system condition. The impact of several parameters on maintenance strategy, such as operating cost and revenue, system failure characteristics, repair and replacement costs, and the planning time horizon, is explored. This approach provides a quantitative basis on which to base maintenance strategy decisions that contribute to system value. These decisions are different from those suggested by traditional cost-based approaches. The results show (1) how the optimal action for a given time and condition changes as replacement and repair costs change, and identifies the point at which these costs become too high for profitable system operation; (2) that for shorter planning horizons it is better to repair, since there is no time to reap the benefits of increased operating profit and reliability; (3) how the value-optimal maintenance policy is affected by the system's failure characteristics, and hence whether it is worthwhile to invest in higher reliability; and (4) the impact of the repair level on the optimal maintenance policy. -- Highlights: •Provides a quantitative basis for maintenance strategy decisions that contribute to system value. •Shows how the optimal action for a given condition changes as replacement and repair costs change. •Shows how the optimal policy is affected by the system's failure characteristics. •Shows when it is

  1. Design and Analysis of a Stiffened Composite Structure Repair Concept

    Science.gov (United States)

    Przekop, Adam

    2011-01-01

    A design and analysis of a repair concept applicable to a stiffened thin-skin composite panel based on the Pultruded Rod Stitched Efficient Unitized Structure is presented. Since the repair concept is a bolted repair using metal components, it can easily be applied in the operational environment. Initial analyses are aimed at validating the finite element modeling approach by comparing with available test data. Once confidence in the analysis approach is established several repair configurations are explored and the most efficient one presented. Repairs involving damage to the top of the stiffener alone are considered in addition to repairs involving a damaged stiffener, flange and underlying skin. High fidelity finite element modeling techniques such as mesh-independent definition of compliant fasteners, elastic-plastic metallic material properties and geometrically nonlinear analysis are utilized in the effort. The results of the analysis are presented and factors influencing the design are assessed and discussed.

  2. Mechanical characterization of composite repairs for fiberglass wind turbine blades

    Science.gov (United States)

    Chawla, Tanveer Singh

    affects the propagation fracture toughness values of the repair. Repairs conducted on surfaces with partially ground top plies possess higher fracture toughness values than those conducted on surfaces with complete top plies ground off. The three top repair resin candidates were then evaluated against the base repair resin under fatigue loading. The specimen configuration and testing method were chosen so as to be able to test hand layup repairs under tension -- tension cyclic loading. It was observed that all three new repair resins perform better than the base repair resin. The selection of the optimum repair resin was based on results from mode I and fatigue testing. Global manufacturing regulations and standards were also of prime concern. The final new repair resin is being used by the company in all of its plants over the globe. The balance of this work involves study of the effect of mixed mode I -- mode II loading on the strength of repairs conducted on fiber reinforced composite parts using hand lay-up technique. The specimens for this part were similar to those manufactured for mode I testing but with different dimensions and layup. They were made and tested in accordance with ASTM D 6671 (Standard Test Method for Mixed Mode I -- Mode II Interlaminar Fracture Toughness of Unidirectional Fiber Reinforced Polymer Matrix Composites). Comparison was made between the fracture toughness of the above chosen optimum repair resin and the base repair resin. At least two levels of mode mixture GII/G (Mode II fracture toughness / Mode I and II fracture toughness) were examined. Also, two levels of grinding were considered (complete ply vs. partial ply ground off) in order to establish the influence of varying top-ply grinding depths on the strength of hand layup repairs conducted on fiberglass composite structures. The results of this work have the potential to improve the repair process for current fiberglass wind turbine blades.

  3. Repairing fuel for reinsertion

    International Nuclear Information System (INIS)

    Krukshenk, A.

    1986-01-01

    Eqiupment for nuclear reactor fuel assembly repairing produced by Westinghouse and Brawn Bovery companies is described. Repair of failed fuel assemblies replacement of defect fuel elements gives a noticeable economical effect. Thus if the cost of a new fuel assembly is 450-500 thousand dollars, the replacement of one fuel element in it costs approximately 40-60 thousand dollars. In simple cases repairing includes either removal of failed fuel elements from a fuel assembly and its reinsertion with the rest of fuel elements into the reactor core (reactor refueling), or replacement of unfailed fuel elements from one fuel assembly to a new one (fuel assembly overhaul and reconditioning)

  4. ONSTEP versus laparoscopy for inguinal hernia repair

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-01

    repair. Patients are recruited from surgical departments in Denmark and follow-up is one year. In total, 188 patients will be included. DISCUSSION: This protocol describes one of the first randomised clinical trials investigating the ONSTEP technique. To our knowledge, it is the first clinical trial...

  5. Auto Body Repair 103, 203, 303.

    Science.gov (United States)

    Manitoba Dept. of Education, Winnipeg.

    As part of the high school vocational industrial program in Manitoba, this course has been designed to provide students with the foundation for a career in auto-body repair. The program introduces and provides opportunities for student skill development in the theories and techniques of tool and equipment operation, metallurgy and welding, damage…

  6. New Technology in Automotive Body Repair.

    Science.gov (United States)

    Maze, Ronald W.

    1980-01-01

    The use of plastic and fiberglass materials in the manufacture of automobiles has caused a revolution in the field of collision work. Changes have occurred in tools, techniques, materials, and in the training for auto body repair. The skills necessary for employment in this field are now easier and faster to acquire. (CT)

  7. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review.

    Science.gov (United States)

    Yousif, Matthew John; Bicos, James

    2017-12-01

    The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss the previous case series of double-row fixation. Narrative review. A simple review of the literature was performed by PubMed search. Only biomechanical studies comparing single- versus double-row capsulolabral repair were included for review. Only those case series and descriptive techniques with clinical results for double-row repair were included in the discussion. Biomechanical comparisons evaluating the native footprint of the labrum demonstrated significantly superior restoration of the footprint through double-row capsulolabral repair compared with single-row repair. Biomechanical comparisons of contact pressure at the repair interface, fracture displacement in bony Bankart lesion, load to failure, and decreased external rotation (suggestive of increased load to failure) were also significantly in favor of double- versus single-row repair. Recent descriptive techniques and case series of double-row fixation have demonstrated good clinical outcomes; however, no comparative clinical studies between single- and double-row repair have assessed functional outcomes. The superiority of double-row capsulolabral repair versus single-row repair remains uncertain because comparative studies assessing clinical outcomes have yet to be performed.

  8. Motor vehicle stocks, scrappage, and sales

    OpenAIRE

    Alan Greenspan; Darrel Cohen

    1996-01-01

    This paper offers a framework for forecasting aggregate sales of new motor vehicles; this framework incorporates separate models for the change in the vehicle stock and for the rate of vehicle scrappage. Because this approach requires only a minimal set of assumptions about demographic trends, the state of the economy, consumer ''preferences,'' new vehicle prices and repair costs, and vehicle retirements, it is shown to be especially useful as a macroeconomic forecasting tool. In addition, th...

  9. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    . Discussion: Laparoscopy has advantages over open surgery in that it is associated with less pain, shorter length of hospital stay, better cosmesis, quicker recovery, and equal efficacy. Although cases of VUF are rarely noted, the laparoscopic skill obtained through other urological procedures suggest, that laparoscopic repair may be the procedure of choice for such cases (2. The reported operative time for the laparoscopic repair of VUF in the literature varies between 140 and 220 min (3. However, laparoscopic techniques should be considered as a mode of abdominal access and should not influence the method of surgical repair. Surgical success should depend on the adherence to good technique rather than the approach. Hence, this method appears to be a viable alternative for surgeons experienced with laparoscopic suturing techniques. Conclusion: Laparoscopic repair appears to be a viable alternative for surgeons experienced with laparoscopic suturing techniques.

  10. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  11. Inguinal hernia repair: anaesthesia, pain and convalescence

    DEFF Research Database (Denmark)

    Callesen, Torben

    2003-01-01

    of less serious complications is lower by local anaesthesia, compared to other anaesthetic techniques. Of special interest is, that the rate of urinary retention can be eliminated by the use of local anaesthesia. Local anaesthesia results, in comparative studies, in a higher degree of patient satisfaction...... than other anaesthetic techniques. Local anaesthesia also facilitates faster mobilisation and earlier discharge/fulfilment of discharge criteria from post anaesthetic care units than other anaesthetic techniques. Pain after hernia repair is more pronounced at mobilisation or coughing than during rest....... Pain after laparoscopic surgery is less pronounced than after open surgery, while different open repair techniques do not exhibit significant differences. Postoperative pain is best treated with a combination of local analgesia and peripherally acting agents (paracetamol, NSAID or their combination...

  12. Ultrasound-guided compression repair of pseudoaneurysms of brachial and femoral arteries - 2 cases-

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Choi, Yeon Hyeon; Kim, Ji Eun; Lee, Sang Hoon; Kim, Myung A; Kim, Tae Kyoung; Cho, Jae Min

    1994-01-01

    Ultrasound-guided compression repair of postcatherization pseudoaneurysm has been reported recently. We successfuly treated two cases of cardiac catherization-related pseudoaneurysms of brachial and femoral arteries with compression repair technique under color Doppler US-guidance. We regard US-guided compression repair as a saft and effective first-line treatment for catherization-related pseudoaneurysm

  13. DNA Repair Systems

    Indian Academy of Sciences (India)

    DNA molecule which makes it ideal for storage and propagation of genetic information. ... of these errors are broadly referred to as DNA repair. DNA can ... changes occur in the human genome per day. ..... nails, frequent physical and mental.

  14. Brain aneurysm repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000123.htm Brain aneurysm repair - discharge To use the sharing features ... this page, please enable JavaScript. You had a brain aneurysm . An aneurysm is a weak area in ...

  15. Ventral hernia repair

    Science.gov (United States)

    ... incarcerated) in the hernia and become impossible to push back in. This is usually painful. The blood supply ... you are lying down or that you cannot push back in. Risks The risks of ventral hernia repair ...

  16. Omphalocele repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100033.htm Omphalocele repair - series—Normal anatomy To use the sharing ... Go to slide 4 out of 4 Overview Omphalocele is an abdominal wall defect at the base ...

  17. Reoperation Rates for Laparoscopic vs Open Repair of Femoral Hernias in Denmark

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Bisgaard, Thue; Kehlet, Henrik

    2014-01-01

    IMPORTANCE: In Denmark approximately 10 000 groin hernias are repaired annually, of which 2% to 4% are femoral hernias. Several methods for repair of femoral hernias are used including sutured repair and different types of mesh repair with either open or laparoscopic techniques. The use of many...... laparoscopic vs open femoral hernia repair, analyzing data from a nationwide database. DESIGN, SETTING, AND PARTICIPANTS: A prospective cohort study was conducted. Data on femoral hernia repairs registered in the Danish Hernia Database from January 1998 until February 2012 were extracted and analyzed. All...... repairs were followed in the database and analyzed for reports of reoperation, which were used as a proxy for recurrence. Femoral hernia recurrence and inguinal hernia occurrence after the index repair were analyzed. EXPOSURE: Repair of a femoral hernia. MAIN OUTCOMES AND MEASURES: Reoperation...

  18. [Effect of "Xingnao Kaiqiao Zhenfa" (Acupuncture Technique for Restoring Consciousness) Combined with Rehabilitation Training on Nerve Repair and Expression of Growth-associated Protein-43 of Peri-ischemic Cortex in Ischemic Stroke Rats].

    Science.gov (United States)

    Xu, Lei; Yan, Xing-Zhou; Li, Zhen-Yu; Cao, Xiao-Fang; Wang, Min

    2017-06-25

    To observe the effect of "Xingnao Kaiqiao Zhenfa" (acupuncture technique for restoring consciousness) combined with enriched rehabilitation training on motor function and expression of growth-associated protein-43 (GAP-43) of peri-ischemic cortex in ischemic stroke rats, so as to investigate its mechanism underlying improvement of ischemic stroke. SD rats were randomly divided into sham operation, model, rehabilitation and comprehensive rehabilitation groups, which were further divided into 3 time-points:7, 14 and 21 d ( n =6 in each). Cerebral ischemia(CI) model was established by occlusion of the middle cerebral artery with heat-coagulation. The rehabilitation group was treated by enriched rehabilitation training, once a day. The comprehensive rehabilitation group was treated by acupuncture combined with enriched rehabilitation training. Acupuncture was applied to bilateral "Neiguan"(PC 6) and "Shuigou"(GV 26) for 30 min, once a day. The neurological function score, balance-beam walking test and rotating-rod walking test were evaluated at the end of the corresponding treatment time. The expression of GAP-43 in peri-ischemic cortex was detected by immunohistochemistry. In comparison with the sham operation group, the scores of neurological function, beam walking test and rotating-rod walking test were significantly higher in the model group ( P beam walking and rotating-rod walking tests in the rehabilitation group compared with the model group on day 7 ( P >0.05). Compared with the model group at the other time points, the scores of neurological function, balance-beam walking test and rotating-rod walking test were significantly lower in the rehabilitation and comprehensive rehabilitation groups ( P beam walking test and rotating-rod walking test were significantly lower in the comprehensive rehabilitation group ( P <0.05). In comparison with the sham operation group, the number of GAP-43 positive cells of peri-ischemic cortex was significantly higher in the

  19. Remodeling of motor units after nerve regeneration studied by quantitative electromyography

    DEFF Research Database (Denmark)

    Krarup, Christian; Boeckstyns, Michel; Ibsen, Allan

    2016-01-01

    different types of nerve repair. Methods: Reinnervation of muscle was compared clinically and electrophysiologically in complete median or ulnar nerve lesions with short gap lengths in the distal forearm repaired with a collagen nerve conduit (11 nerves) or nerve suture (10 nerves). Reestablishment of motor...

  20. Fine motor control

    Science.gov (United States)

    ... gross (large, general) motor control. An example of gross motor control is waving an arm in greeting. Problems ... out the child's developmental age. Children develop fine motor skills over time, by practicing and being taught. To ...

  1. Celebrating DNA's Repair Crew.

    Science.gov (United States)

    Kunkel, Thomas A

    2015-12-03

    This year, the Nobel Prize in Chemistry has been awarded to Tomas Lindahl, Aziz Sancar, and Paul Modrich for their seminal studies of the mechanisms by which cells from bacteria to man repair DNA damage that is generated by normal cellular metabolism and stress from the environment. These studies beautifully illustrate the remarkable power of DNA repair to influence life from evolution through disease susceptibility. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Laparoscopic totally extraperitoneal inguinal hernia repair: lessons learned from 3,100 hernia repairs over 15 years.

    Science.gov (United States)

    Dulucq, Jean-Louis; Wintringer, Pascal; Mahajna, Ahmad

    2009-03-01

    Two revolutions in inguinal hernia repair surgery have occurred during the last two decades. The first was the introduction of tension-free hernia repair by Liechtenstein in 1989 and the second was the application of laparoscopic surgery to the treatment of inguinal hernia in the early 1990s. The purposes of this study were to assess the safety and effectiveness of laparoscopic totally extraperitoneal (TEP) repair and to discuss the technical changes that we faced on the basis of our accumulative experience. Patients who underwent an elective inguinal hernia repair at the Department of Abdominal Surgery at the Institute of Laparoscopic Surgery (ILS), Bordeaux, between June 1990 and May 2005 were enrolled retrospectively in this study. Patient demographic data, operative and postoperative course, and outpatient follow-up were studied. A total of 3,100 hernia repairs were included in the study. The majority of the hernias were repaired by TEP technique; the repair was done by transabdominal preperitoneal (TAPP) repair in only 3%. Eleven percent of the hernias were recurrences after conventional repair. Mean operative time was 17 min in unilateral hernia and 24 min in bilateral hernia. There were 36 hernias (1.2%) that required conversion: 12 hernias were converted to open anterior Liechtenstein and 24 to laparoscopic TAPP technique. The incidence of intraoperative complications was low. Most of the patients were discharged at the second day of the surgery. The overall postoperative morbidity rate was 2.2%. The incidence of recurrence rate was 0.35%. The recurrence rate for the first 200 repairs was 2.5%, but it decreased to 0.47% for the subsequent 1,254 hernia repairs According to our experience, in the hands of experienced laparoscopic surgeons, laparoscopic hernia repair seems to be the favored approach for most types of inguinal hernias. TEP is preferred over TAPP as the peritoneum is not violated and there are fewer intra-abdominal complications.

  3. Prosthetic Mesh Repair for Incarcerated Inguinal Hernia

    Directory of Open Access Journals (Sweden)

    Cihad Tatar

    2016-08-01

    Full Text Available Background: Incarcerated inguinal hernia is a commonly encountered urgent surgical condition, and tension-free repair is a well-established method for the treatment of noncomplicated cases. However, due to the risk of prosthetic material-related infections, the use of mesh in the repair of strangulated or incarcerated hernia has often been subject to debate. Recent studies have demonstrated that biomaterials represent suitable materials for performing urgent hernia repair. Certain studies recommend mesh repair only for cases where no bowel resection is required; other studies, however, recommend mesh repair for patients requiring bowel resection as well. Aim: The aim of this study was to compare the outcomes of different surgical techniques performed for strangulated hernia, and to evaluate the effect of mesh use on postoperative complications. Study Design: Retrospective cross-sectional study. Methods: This retrospective study was performed with 151 patients who had been admitted to our hospital’s emergency department to undergo surgery for a diagnosis of incarcerated inguinal hernia. The patients were divided into two groups based on the applied surgical technique. Group 1 consisted of 112 patients treated with mesh-based repair techniques, while Group 2 consisted of 39 patients treated with tissue repair techniques. Patients in Group 1 were further divided into two sub-groups: one consisting of patients undergoing bowel resection (Group 3, and the other consisting of patients not undergoing bowel resection (Group 4. Results: In Group 1, it was observed that eight (7.14% of the patients had wound infections, while two (1.78% had hematomas, four (3.57% had seromas, and one (0.89% had relapse. In Group 2, one (2.56% of the patients had a wound infection, while three (7.69% had hematomas, one (2.56% had seroma, and none had relapses. There were no statistically significant differences between the two groups with respect to wound infection

  4. Analytical system availability techniques

    NARCIS (Netherlands)

    Brouwers, J.J.H.; Verbeek, P.H.J.; Thomson, W.R.

    1987-01-01

    Analytical techniques are presented to assess the probability distributions and related statistical parameters of loss of production from equipment networks subject to random failures and repairs. The techniques are based on a theoretical model for system availability, which was further developed

  5. Use of hydroxyurea in the measurement of DNA repair by the BND cellulose method

    International Nuclear Information System (INIS)

    Irwin, J.; Strauss, B.

    1980-01-01

    Hydroxyurea inhibition is a convenient method of suppressing replicative DNA synthesis for DNA excision-repair measurement by the BND cellulose technique. Nonetheless, hydroxyurea can introduce artefacts by direct reaction with repair-inducing compounds and by long-term inhibition of the overall repair process. A simple technique of overcoming these problems is described. Cells are reacted with repair-inducing compounds in the absence of hydroxyurea, the cells are washed free of inducer, hydroxyurea is added to 2 mM, and after a short period to establish replication inhibition, 3 H dThd is added and repair measured over a one-hour incubation period

  6. Biomechanical Comparison of Single- Versus Double-Row Capsulolabral Repair for Shoulder Instability: A Review

    OpenAIRE

    Yousif, Matthew John; Bicos, James

    2017-01-01

    Background: The glenohumeral joint is the most commonly dislocated joint in the body. Failure rates of capsulolabral repair have been reported to be approximately 8%. Recent focus has been on restoration of the capsulolabral complex by a double-row capsulolabral repair technique in an effort to decrease redislocation rates after arthroscopic capsulolabral repair. Purpose: To present a review of the biomechanical literature comparing single- versus double-row capsulolabral repairs and discuss ...

  7. The Biomechanical Role of Scaffolds in Augmented Rotator Cuff Tendon Repairs

    Science.gov (United States)

    2012-01-01

    The biomechanical role of scaffolds in augmented rotator cuff tendon repairs Amit Aurora, D Enga,b, Jesse A. McCarron, MDc, Antonie J. van den Bogert...used for rotator cuff repair augmentation; however, the appropriate scaffold material properties and/or surgical application techniques for achieving...The model predicts that the biomechanical performance of a rotator cuff repair can be modestly increased by augmenting the repair with a scaffold that

  8. [Compressive anterior thoracoplasty (modified Abramson's repair) for pectus carinatum repair].

    Science.gov (United States)

    Álvarez Muñoz, V; Prado Valle, M A; López López, A J; Martínez Suárez, M A; Oviedo Gutiérrez, M; Montalvo Ávalos, C; Fernández García, L

    2014-04-15

    For anterior protruding chest wall deformities treatment, mainly pectus carinatum, pediatric surgeons have been managing either orthotic methods or open surgical repairs. Anterior compressive thoracoplasty (Abramson's technique) has widened the therapeutic options. We describe herein a modification of this technique in the first reported Europen series. From 2010 to 2012, a total of five patients (four male and one female) underwent a modified Abramson's technique to correct pectus carinatum or combined protrusion of the chest at our center. We report the operative technique used for these reconstructions. In all five cases, the operation was completed uneventfully and with excellent results either for the surgical team or the patients. Mean operative time was 190 minutes and hospitalization lasted for three to six days, at the time of analgesic drugs withdrawal. We consider the anterior compresive thorocoplasty (modified Abramson's technique) a safe and feasible method to correct protruding chest deformities, particularly in those patients with stiff chest or lack of compliance, in order to avoid the agressive open procedures.

  9. Underwater inspection, repair and reconstitution of water reactor fuel

    International Nuclear Information System (INIS)

    1988-06-01

    On-site fuel examination plays an important role for evaluation of fuel irradiation performance under reactor operating conditions. Also fuel assembly repairs are economically very attractive for operating nuclear utilities. The status of the processes of examination and repair, equipment used and research plans in Member States are reviewed in these Proceedings. All presentations were divided into three sessions: inspection diagnostic: facilities, techniques, and programmes (8 papers); repair and reconstitution techniques (6 papers); power plant experience (6 papers). A separate abstract was prepared for each of these 20 papers. Refs, figs and tabs

  10. Motor control for a brushless DC motor

    Science.gov (United States)

    Peterson, William J. (Inventor); Faulkner, Dennis T. (Inventor)

    1985-01-01

    This invention relates to a motor control system for a brushless DC motor having an inverter responsively coupled to the motor control system and in power transmitting relationship to the motor. The motor control system includes a motor rotor speed detecting unit that provides a pulsed waveform signal proportional to rotor speed. This pulsed waveform signal is delivered to the inverter to thereby cause an inverter fundamental current waveform output to the motor to be switched at a rate proportional to said rotor speed. In addition, the fundamental current waveform is also pulse width modulated at a rate proportional to the rotor speed. A fundamental current waveform phase advance circuit is controllingly coupled to the inverter. The phase advance circuit is coupled to receive the pulsed waveform signal from the motor rotor speed detecting unit and phase advance the pulsed waveform signal as a predetermined function of motor speed to thereby cause the fundamental current waveform to be advanced and thereby compensate for fundamental current waveform lag due to motor winding reactance which allows the motor to operate at higher speeds than the motor is rated while providing optimal torque and therefore increased efficiency.

  11. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Cost-effectiveness of open versus arthroscopic rotator cuff repair.

    Science.gov (United States)

    Adla, Deepthi N; Rowsell, Mark; Pandey, Radhakant

    2010-03-01

    Economic evaluation of surgical procedures is necessary in view of more expensive newer techniques emerging in an increasingly cost-conscious health care environment. This study compares the cost-effectiveness of open rotator cuff repair with arthroscopic repair for moderately size tears. This was a prospective study of 30 consecutive patients, of whom 15 had an arthroscopic repair and 15 had an open procedure. Clinical effectiveness was assessed using Oxford and Constant shoulder scores. Costs were estimated from departmental and hospital financial data. At last follow-up, no difference Oxford and Constant shoulder scores was noted between the 2 methods of repair. There was no significant difference between the groups in the cost of time in the operating theater, inpatient time, amount of postoperative analgesia, number of postoperative outpatient visits, physiotherapy costs, and time off work. The incremental cost of each arthroscopic rotator cuff repair was pound675 ($1248.75) more than the open procedure. This was mainly in the area of direct health care costs, instrumentation in particular. Health care policy makers are increasingly demanding evidence of cost-effectiveness of a procedure. This study showed both methods of repair provide equivalent clinical results. Open cuff repair is more cost-effective than arthroscopic repair and is likely to have lower cost-utility ratio. In addition, the tariff for the arthroscopic procedure in some health care systems is same as open repair. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Repair of damaged DNA in vivo: Final technical report

    International Nuclear Information System (INIS)

    Hanawalt, P.C.

    1987-09-01

    This contract was initiated in 1962 with the US Atomic Energy Commission to carry out basic research on the effects of radiation on the process of DNA replication in bacteria. Within the first contract year we discovered repair replication at the same time that Setlow and Carrier discovered pyrimidine dimer excision. These discoveries led to the elucidation of the process of excision-repair, one of the most important mechanisms by which living systems, including humans, respond to structural damage in their genetic material. We improved methodology for distinguishing repair replication from semiconservative replication and instructed others in these techniques. Painter then was the first to demonstrate repair replication in ultraviolet irradiated human cells. He, in turn, instructed James Cleaver who discovered that skin fibroblasts from patients with xeroderma pigmentosum were defective in excision-repair. People with this genetic defect are extremely sensitive to sunlight and they develop carcinomas and melanomas of the skin with high frequency. The existence of this hereditary disease attests to the importance of DNA repair in man. We certainly could not survive in the normal ultraviolet flux from the sun if our DNA were not continuously monitored for damage and repaired. Other hereditary diseases such as ataxia telangiectasia, Cockayne's syndrome, Blooms syndrome and Fanconi's anemia also involve deficiencies in DNA damage processing. The field of DNA repair has developed rapidly as we have learned that most environmental chemical carcinogens as well as radiation produce repairable damage in DNA. 251 refs

  14. BMCloud: Minimizing Repair Bandwidth and Maintenance Cost in Cloud Storage

    Directory of Open Access Journals (Sweden)

    Chao Yin

    2013-01-01

    Full Text Available To protect data in cloud storage, fault tolerance and efficient recovery become very important. Recent studies have developed numerous solutions based on erasure code techniques to solve this problem using functional repairs. However, there are two limitations to address. The first one is consistency since the Encoding Matrix (EM is different among clouds. The other one is repairing bandwidth, which is a concern for most of us. We addressed these two problems from both theoretical and practical perspectives. We developed BMCloud, a new low repair bandwidth, low maintenance cost cloud storage system, which aims to reduce repair bandwidth and maintenance cost. The system employs both functional repair and exact repair while it inherits advantages from the both. We propose the JUDGE_STYLE algorithm, which can judge whether the system should adopt exact repair or functional repair. We implemented a networked storage system prototype and demonstrated our findings. Compared with existing solutions, BMCloud can be used in engineering to save repair bandwidth and degrade maintenance significantly.

  15. High efficiency motors; Motores de alta eficiencia

    Energy Technology Data Exchange (ETDEWEB)

    Uranga Favela, Ivan Jaime [Energia Controlada de Mexico, S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    This paper is a technical-financial study of the high efficiency and super-premium motors. As it is widely known, more than 60% of the electrical energy generated in the country is used for the operation of motors, in industry as well as in commerce. Therefore the importance that the motors have in the efficient energy use. [Espanol] El presente trabajo es un estudio tecnico-financiero de los motores de alta eficiencia y los motores super premium. Como es ampliamente conocido, mas del 60% de la energia electrica generada en el pais, es utilizada para accionar motores, dentro de la industria y el comercio. De alli la importancia que los motores tienen en el uso eficiente de la energia.

  16. High efficiency motors; Motores de alta eficiencia

    Energy Technology Data Exchange (ETDEWEB)

    Uranga Favela, Ivan Jaime [Energia Controlada de Mexico, S. A. de C. V., Mexico, D. F. (Mexico)

    1992-12-31

    This paper is a technical-financial study of the high efficiency and super-premium motors. As it is widely known, more than 60% of the electrical energy generated in the country is used for the operation of motors, in industry as well as in commerce. Therefore the importance that the motors have in the efficient energy use. [Espanol] El presente trabajo es un estudio tecnico-financiero de los motores de alta eficiencia y los motores super premium. Como es ampliamente conocido, mas del 60% de la energia electrica generada en el pais, es utilizada para accionar motores, dentro de la industria y el comercio. De alli la importancia que los motores tienen en el uso eficiente de la energia.

  17. Motor operated valve stroke timing; is there value?

    International Nuclear Information System (INIS)

    Green, K.; Rosch, F. Jr.; Neckowicz, T.

    1990-01-01

    Both ASME Section XI, Subsection IWV and ASME/ANSI OMa-1988, Part 10 require stroke timing of certain power operated valves. This requirement is intended to detect valve degradation and subsequent maintenance, repair or replacement needs. However, the adequacy of stroke timing, especially for motor operated valves, has met much skepticism in the industry. This paper will demonstrate that stroke timing for ac motor operated valves is inadequate and provide a non-intrusive testing alternative. It will also discuss the value of stroke timing for dc motor operated valves

  18. Modular PM Motor Drives for Automotive Traction Applications

    International Nuclear Information System (INIS)

    Su, G.J.

    2001-01-01

    This paper presents modular permanent magnet (PM) motor drives for automotive traction applications. A partially modularized drive system consisting of a single PM motor and multiple inverters is described. The motor has multiple three-phase stator winding sets and each winding set is driven with a separate three-phase inverter module. A truly modularized inverter and motor configuration based on an axial-gap PM motor is then introduced, in which identical PM motor modules are mounted on a common shaft and each motor module is powered by a separate inverter module. The advantages of the modular approach for both inverter and motor include: (1) power rating scalability-one design meets different power requirements by simply stacking an adequate number of modules, thus avoiding redesigning and reducing the development cost, (2) increased fault tolerance, and (3) easy repairing. A prototype was constructed by using two inverters and an axial-gap PM motor with two sets of three-phase stat or windings, and it is used to assist the diesel engine in a hybrid electric vehicle converted from a Chevrolet Suburban. The effect of different pulse-width-modulation strategies for both motoring and regenerative modes on current control is analyzed. Torque and regenerative control algorithms are implemented with a digital signal processor. Analytical and initial testing results are included in the paper

  19. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  20. Radiobiological significance of DNA repair

    International Nuclear Information System (INIS)

    Kuzin, A.M.

    1978-01-01

    A short outline is given on the history of the problem relating to the repair of radiation injuries, specifically its molecular mechanisms. The most urgent problems which currently confront the researchers are noted. This is a further study on the role of DNA repair in post-radiation recovery, search for ways to activate and suppress DNA repair, investigations into the activity balance of various repair enzymes as well as the problem of errors in the structure of repairing DNA. An important role is attached to the investigations of DNA repair in solving a number of practical problems

  1. Recombinational repair: workshop summary

    International Nuclear Information System (INIS)

    Howard-Flanders, P.

    1983-01-01

    Recombinational repair may or may not be synonymous with postreplication repair. Considerable progress has been made in the study of the relevant enzymes, particularly those from bacteria. In this workshop we focus on the recombination enzyme RecA protein. What structural changes take place in the protein and in DNA during repair. How does homologous pairing take place. How is ATP hydrolysis coupled to the stand exchange reaction and the formation of heteroduplx DNA. Turning to another enzyme needed for certain kinds of bacterial recombination, we will ask whether the purified recB protein and recC protein complement each other and are sufficient for exonuclease V activity. In higher cells, we would like to know whether sister exchanges, which occur in bacteria after uv irradiation, are also seen in animal cells

  2. Anterior cruciate ligament repair - past, present and future.

    Science.gov (United States)

    Mahapatra, Piyush; Horriat, Saman; Anand, Bobby S

    2018-06-15

    This article provides a detailed narrative review on the history and current concepts surrounding ligamentous repair techniques in athletic patients. In particular, we will focus on the anterior cruciate ligament (ACL) as a case study in ligament injury and ligamentous repair techniques. PubMed (MEDLINE), EMBASE and Cochrane Library databases for papers relating to primary anterior cruciate ligament reconstruction were searched by all participating authors. All relevant historical papers were included for analysis. Additional searches of the same databases were made for papers relating to biological enhancement of ligament healing. The poor capacity of the ACL to heal is one of the main reasons why the current gold standard surgical treatment for an ACL injury in an athletic patient is ACL reconstruction with autograft from either the hamstrings or patella tendon. It is hypothesised that by preserving and repairing native tissues and negating the need for autograft that primary ACL repair may represent a key step change in the treatment of ACL injuries. The history of primary ACL repair will be discussed and the circumstances that led to the near-abandonment of primary ACL repair techniques will be reviewed. There has been a recent resurgence in interest with regards to primary ACL repair. Improvements in imaging now allow for identification of tear location, with femoral-sided injuries, being more suitable for repair. We will discuss in details strategies for improving the mechanical and biological environment in order to allow primary healing to occur. In particular, we will explain mechanical supplementation such as Internal Brace Ligament Augmentation and Dynamic Intraligamentary Stabilisation techniques. These are novel techniques that aim to protect the primary repair by providing a stabilising construct that connects the femur and the tibia, thus bridging the repair. In addition, biological supplementation is being investigated as an adjunct and we will

  3. Motor demand-dependent activation of ipsilateral motor cortex.

    Science.gov (United States)

    Buetefisch, Cathrin M; Revill, Kate Pirog; Shuster, Linda; Hines, Benjamin; Parsons, Michael

    2014-08-15

    The role of ipsilateral primary motor cortex (M1) in hand motor control during complex task performance remains controversial. Bilateral M1 activation is inconsistently observed in functional (f)MRI studies of unilateral hand performance. Two factors limit the interpretation of these data. As the motor tasks differ qualitatively in these studies, it is conceivable that M1 contributions differ with the demand on skillfulness. Second, most studies lack the verification of a strictly unilateral execution of the motor task during the acquisition of imaging data. Here, we use fMRI to determine whether ipsilateral M1 activity depends on the demand for precision in a pointing task where precision varied quantitatively while movement trajectories remained equal. Thirteen healthy participants used an MRI-compatible joystick to point to targets of four different sizes in a block design. A clustered acquisition technique allowed simultaneous fMRI/EMG data collection and confirmed that movements were strictly unilateral. Accuracy of performance increased with target size. Overall, the pointing task revealed activation in contralateral and ipsilateral M1, extending into contralateral somatosensory and parietal areas. Target size-dependent activation differences were found in ipsilateral M1 extending into the temporal/parietal junction, where activation increased with increasing demand on accuracy. The results suggest that ipsilateral M1 is active during the execution of a unilateral motor task and that its activity is modulated by the demand on precision. Copyright © 2014 the American Physiological Society.

  4. Superficial or deep implantation of motor nerve after denervation: an experimental study--superficial or deep implantation of motor nerve.

    Science.gov (United States)

    Askar, Ibrahím; Sabuncuoglu, Bízden Tavíl

    2002-01-01

    Neurorraphy, conventional nerve grafting technique, and artificial nerve conduits are not enough for repair in severe injuries of peripheral nerves, especially when there is separation of motor nerve from muscle tissue. In these nerve injuries, reinnervation is indicated for neurotization. The distal end of a peripheral nerve is divided into fascicles and implanted into the aneural zone of target muscle tissue. It is not known how deeply fascicles should be implanted into muscle tissue. A comparative study of superficial and deep implantation of separated motor nerve into muscle tissue is presented in the gastrocnemius muscle of rabbits. In this experimental study, 30 white New Zealand rabbits were used and divided into 3 groups of 10 rabbits each. In the first group (controls, group I), only surgical exposure of the gastrocnemius muscle and motor nerve (tibial nerve) was done without any injury to nerves. In the superficial implantation group (group II), tibial nerves were separated and divided into their own fascicles. These fascicles were implanted superficially into the lateral head of gastrocnemius muscle-aneural zone. In the deep implantation group (group III), the tibial nerves were separated and divided into their own fascicles. These fascicles were implanted around the center of the muscle mass, into the lateral head of the gastrocnemius muscle-aneural zone. Six months later, histopathological changes and functional recovery of the gastrocnemius muscle were investigated. Both experimental groups had less muscular weight than in the control group. It was found that functional recovery was achieved in both experimental groups, and was better in the superficial implantation group than the deep implantation group. EMG recordings revealed that polyphasic and late potentials were frequently seen in both experimental groups. Degeneration and regeneration of myofibrils were observed in both experimental groups. New motor end-plates were formed in a scattered

  5. DNA repair and cancer

    International Nuclear Information System (INIS)

    Rathore, Shakuntla; Joshi, Pankaj Kumar; Gaur, Sudha

    2012-01-01

    DNA repair refers to a collection of processes by which a cell identifies and corrects damage to the DNA molecule that encode it's genome. In human cells, both normal metabolic activities and environmental factors such as UV light and radiation can cause DNA damage, resulting in as many one million individual molecular lesions per day. Many of these lesions cause structural damage to the DNA molecule and can alter or eliminate the cell's ability to transcribe the gene that the affected DNA encodes. Other lesions include potentially harmful mutation in cell's genome which affect the survival of it's daughter cells after it undergoes mitosis. As a consequence, the DNA repair process is constantly active as it responds to damage in the DNA structure. Inherited mutation that affect DNA repair genes are strongly associated with high cancer risks in humans. Hereditary non polyposis colorectal cancer (HNPCC) is strongly associated with specific mutation in the DNA mismatch repair pathway. BRCA1, BRCA2 two famous mutation conferring a hugely increased risk of breast cancer on carrier, are both associated with a large number of DNA repair pathway, especially NHEJ and homologous recombination. Cancer therapy procedures such as chemotherapy and radiotherapy work by overwhelming the capacity of the cell to repair DNA damage, resulting in cell death. Cells that are most rapidly dividing most typically cancer cells are preferentially affected. The side effect is that other non-cancerous but rapidly dividing cells such as stem cells in the bone marrow are also affected. Modern cancer treatment attempt to localize the DNA damage to cells and tissue only associated with cancer, either by physical means (concentrating the therapeutic agent in the region of the tumor) or by biochemical means (exploiting a feature unique to cancer cells in the body). (author)

  6. Surgical management of colorectal injuries: colostomy or primary repair?

    Science.gov (United States)

    Papadopoulos, V N; Michalopoulos, A; Apostolidis, S; Paramythiotis, D; Ioannidis, A; Mekras, A; Panidis, S; Stavrou, G; Basdanis, G

    2011-10-01

    Several factors have been considered important for the decision between diversion and primary repair in the surgical management of colorectal injuries. The aim of this study is to clarify whether patients with colorectal injuries need diversion or not. From 2008 to 2010, ten patients with colorectal injuries were surgically treated by primary repair or by a staged repair. The patients were five men and five women, with median age 40 years (20-55). Two men and two women had rectal injuries, while 6 patients had colon injuries. The mechanism of trauma in two patients was firearm injuries, in two patients was a stab injury, in four patients was a motor vehicle accident, in one woman was iatrogenic injury during vaginal delivery, and one case was the transanal foreign body insertion. Primary repair was possible in six patients, while diversion was necessary in four patients. Primary repair should be attempted in the initial surgical management of all penetrating colon and intraperitoneal rectal injuries. Diversion of colonic injuries should only be considered if the colon tissue itself is inappropriate for repair due to severe edema or ischemia. The role of diversion in the management of unrepaired extraperitoneal rectal injuries and in cases with anal sphincter injuries is mandatory.

  7. Repair of the spondylolysis in lumbar spine

    International Nuclear Information System (INIS)

    Matta Ibarra, Javier; Arrieta Maria, Victor; Torres Romero Fernando; Ramirez Cabrales, Vladimir

    2005-01-01

    The objective is to present the surgical experience in the repair of the spondylolysis in lumbar spine. Background: Spodylolysis is an important cause of low back pain in young adults and is responsible for high grade of incapacity. Classically, patients with surgical indications with Spondylolysis have been treated with vertebral arthrodesis arthrodesis, with the following functional lost of the intervened segment and biomechanical overload of the upper contiguous segment. There are not previous reports about repairing of lysis in national literature and international references in this technique are scarce. Materials and methods: Eight patients within 2002-2004 were operated, a direct repairing of the lyses by in situ, fusion and interfragmental osteosynthesis with AO 3.5 mm titanium cortical screws with autogenous bone grafts was achieved. The casuistic was analyzed depending on clinical presentation, consolidation, mobility and vitality of the disc in imaginology studies. Results: During the follow-up a firm fusion in all cases, mobility and vitality preservation of the L5-S1 intervertebral disc was detected. There was neither infection nor neurological deficit. Recommendations: Repairing of spondylolysis in lumbar column, in young symptomatic patients without or with mild lystesis (grade I) and without associated disc damage, is a safe surgical technique

  8. Repair technology for steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating.

  9. Repair technology for steam generator tubes

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Jung, Hyun Kyu; Jung, Seung Ho; Kim, Chang Hoi; Jung, Young Moo; Seo, Yong Chil; Kim, Jung Su; Seo, Moo Hong

    2001-02-01

    The most commonly used sleeving materials are thermally treated Alloy 600 and thermally treated Alloy 690 Alloy. Currently, thermally treated Alloy 690 and Alloy 800 are being offered although Alloy 800 has not been licensed in the US. To install sleeve, joint strength, leak tightness, PWSCC resistance, evaluation on process parameter range and the effect of equipments and procedures on repair plan and radiation damage have to be investigated before sleeving. ABB CE provides three type of leak tight Alloy 690 TIG welded and PLUSS sleeve. Currently, Direct Tube Repair technique using Nd:YAG laser has been developed by ABB CE and Westinghouse. FTI has brazed and kinetic sleeve designs for recirculating steam generator and hydraulic and rolled sleeve designs for one-through steam generators. Westinghouse provides HEJ, brazed and laser welded sleeve design. When sleeve is installed in order to repair the damaged S/G tubes, it is certain that defects can be occurred due to the plastic induced stress and thermal stress. Therefore it is important to minimize the residual stress. FTI provides the electrosleeve technique as a future repair candidate using electroplating

  10. Two Ports Laparoscopic Inguinal Hernia Repair in Children

    OpenAIRE

    Ibrahim, Medhat M.

    2015-01-01

    Introduction. Several laparoscopic treatment techniques were designed for improving the outcome over the last decade. The various techniques differ in their approach to the inguinal internal ring, suturing and knotting techniques, number of ports used in the procedures, and mode of dissection of the hernia sac. Patients and Surgical Technique. 90 children were subjected to surgery and they undergone two-port laparoscopic repair of inguinal hernia in children. Technique feasibility in relation...

  11. Biological radiolesions and repair

    International Nuclear Information System (INIS)

    Laskowski, W.

    1981-01-01

    In 7 chapters, the book answers the following questions: 1) What reactions are induced in biological matter by absorption of radiation energy. 2) In what parts of the cell do the radiation-induced reactions with detectable biological effects occur. 3) In which way are these cell components changed by different qualities of radiation. 4) What are the cell mechanisms by which radiation-induced changes can be repaired. 5) What is the importance of these repair processes for man, his life and evolution. At the end of each chapter, there is a bibliography of relevant publications in this field. (orig./MG) [de

  12. Contemporary methods of emergency repair works on transit pipelines. Repair works on in-service pipelines

    International Nuclear Information System (INIS)

    Olma, T.; Winckowski, J.

    2007-01-01

    The paper presents modern methods and relevant technologies of pipeline failure repairs, basing on TD Williamson technique for hermetic plugging of gas pipelines without interrupting service. Rules for management of emergency situations on the Polish Section of Yamal - Europe Transit Gas Pipeline are being discussed as well. (author)

  13. The Design of Intelligent Repair Welding Mechanism and Relative Control System of Big Gear

    Directory of Open Access Journals (Sweden)

    Hong-Yu LIU

    2014-10-01

    Full Text Available Effective repair of worn big gear has large influence on ensuring safety production and enhancing economic benefits. A kind of intelligent repair welding method was put forward mainly aimed at the big gear restriction conditions of high production cost, long production cycle and high- intensity artificial repair welding work. Big gear repair welding mechanism was designed in this paper. The work principle and part selection of big gear repair welding mechanism was introduced. The three dimensional mode of big gear repair welding mechanism was constructed by Pro/E three dimensional design software. Three dimensional motions can be realized by motor controlling ball screw. According to involute gear feature, the complicated curve motion on curved gear surface can be transformed to linear motion by orientation. By this way, the repair welding on worn gear area can be realized. In the design of big gear repair welding mechanism control system, Siemens S7-200 series hardware was chosen. Siemens STEP7 programming software was chosen as system design tool. The entire repair welding process was simulated by experiment simulation. It provides a kind of practical and feasible method for the intelligent repair welding of big worn gear.

  14. Motor Axonal Regeneration After Partial and Complete Spinal Cord Transection

    Science.gov (United States)

    Lu, Paul; Blesch, Armin; Graham, Lori; Wang, Yaozhi; Samara, Ramsey; Banos, Karla; Haringer, Verena; Havton, Leif; Weishaupt, Nina; Bennett, David; Fouad, Karim; Tuszynski, Mark H.

    2012-01-01

    We subjected rats to either partial mid-cervical or complete upper thoracic spinal cord transections and examined whether combinatorial treatments support motor axonal regeneration into and beyond the lesion. Subjects received cAMP injections into brainstem reticular motor neurons to stimulate their endogenous growth state, bone marrow stromal cell grafts in lesion sites to provide permissive matrices for axonal growth, and brain-derived neurotrophic factor (BDNF) gradients beyond the lesion to stimulate distal growth of motor axons. Findings were compared to several control groups. Combinatorial treatment generated motor axon regeneration beyond both C5 hemisection and complete transection sites. Yet despite formation of synapses with neurons below the lesion, motor outcomes worsened after partial cervical lesions and spasticity worsened after complete transection. These findings highlight the complexity of spinal cord repair, and the need for additional control and shaping of axonal regeneration. PMID:22699902

  15. Karolinska institutet 200-year anniversary. Symposium on traumatic injuries in the nervous system: injuries to the spinal cord and peripheral nervous system - injuries and repair, pain problems, lesions to brachial plexus.

    Science.gov (United States)

    Sköld, Mattias K; Svensson, Mikael; Tsao, Jack; Hultgren, Thomas; Landegren, Thomas; Carlstedt, Thomas; Cullheim, Staffan

    2011-01-01

    The Karolinska Institutet 200-year anniversary symposium on injuries to the spinal cord and peripheral nervous system gathered expertise in the spinal cord, spinal nerve, and peripheral nerve injury field spanning from molecular prerequisites for nerve regeneration to clinical methods in nerve repair and rehabilitation. The topics presented at the meeting covered findings on adult neural stem cells that when transplanted to the hypoglossal nucleus in the rat could integrate with its host and promote neuron survival. Studies on vascularization after intraspinal replantation of ventral nerve roots and microarray studies in ventral root replantation as a tool for mapping of biological patterns typical for neuronal regeneration were discussed. Different immune molecules in neurons and glia and their very specific roles in synapse plasticity after injury were presented. Novel strategies in repair of injured peripheral nerves with ethyl-cyanoacrylate adhesive showed functional recovery comparable to that of conventional epineural sutures. Various aspects on surgical techniques which are available to improve function of the limb, once the nerve regeneration after brachial plexus lesions and repair has reached its limit were presented. Moreover, neurogenic pain after amputation and its treatment with mirror therapy were shown to be followed by dramatic decrease in phantom limb pain. Finally clinical experiences on surgical techniques to repair avulsed spinal nerve root and the motoric as well as sensoric regain of function were presented.

  16. Karolinska Institutet 200-Year Anniversary. Symposium on Traumatic Injuries in the Nervous System: Injuries to the Spinal Cord and Peripheral Nervous System – Injuries and Repair, Pain Problems, Lesions to Brachial Plexus

    Science.gov (United States)

    Sköld, Mattias K.; Svensson, Mikael; Tsao, Jack; Hultgren, Thomas; Landegren, Thomas; Carlstedt, Thomas; Cullheim, Staffan

    2011-01-01

    The Karolinska Institutet 200-year anniversary symposium on injuries to the spinal cord and peripheral nervous system gathered expertise in the spinal cord, spinal nerve, and peripheral nerve injury field spanning from molecular prerequisites for nerve regeneration to clinical methods in nerve repair and rehabilitation. The topics presented at the meeting covered findings on adult neural stem cells that when transplanted to the hypoglossal nucleus in the rat could integrate with its host and promote neuron survival. Studies on vascularization after intraspinal replantation of ventral nerve roots and microarray studies in ventral root replantation as a tool for mapping of biological patterns typical for neuronal regeneration were discussed. Different immune molecules in neurons and glia and their very specific roles in synapse plasticity after injury were presented. Novel strategies in repair of injured peripheral nerves with ethyl-cyanoacrylate adhesive showed functional recovery comparable to that of conventional epineural sutures. Various aspects on surgical techniques which are available to improve function of the limb, once the nerve regeneration after brachial plexus lesions and repair has reached its limit were presented. Moreover, neurogenic pain after amputation and its treatment with mirror therapy were shown to be followed by dramatic decrease in phantom limb pain. Finally clinical experiences on surgical techniques to repair avulsed spinal nerve root and the motoric as well as sensoric regain of function were presented. PMID:21629875

  17. A Comparative Biomechanical Analysis of 2 Double-Row, Distal Triceps Tendon Repairs.

    Science.gov (United States)

    Dorweiler, Matthew A; Van Dyke, Rufus O; Siska, Robert C; Boin, Michael A; DiPaola, Mathew J

    2017-05-01

    Triceps tendon ruptures are rare orthopaedic injuries that almost always require surgical repair. This study tests the biomechanical properties of an original anchorless double-row triceps repair against a previously reported knotless double-row repair. The anchorless double-row triceps repair technique will yield similar biomechanical properties when compared with the knotless double-row repair technique. Controlled laboratory study. Eighteen cadaver arms were randomized into 2 groups. One group received the anchorless repair and the other received the knotless anchor repair. A materials testing system (MTS) machine was used to cycle the repaired arms from 0° to 90° with a 2.5-pound weight for 1500 cycles at 0.25 Hz. Real-time displacement of the tendon was measured during cycling using a probe. Load to failure was performed after completion of cyclic loading. The mean displacement with the anchorless technique was 0.77 mm (SD, 0.25 mm) at 0° (full elbow extension) and 0.76 mm (SD, 0.38 mm) at 90° (elbow flexion). The mean displacement with the anchored technique was 0.83 mm (SD, 0.57 mm) at 0° and 1.01 mm (SD, 0.62 mm) at 90°. There was no statistically significant difference for tendon displacement at 0º ( P = .75) or 90º ( P = .31). The mean load to failure with the anchorless technique was 618.9 N (SD, 185.6 N), while it was 560.5 N (SD, 154.1 N) with the anchored technique, again with no statistically significant difference ( P = .28). Our anchorless double-row triceps repair technique yields comparable biomechanical properties to previously described double-row triceps tendon repair techniques, with the added benefit of avoiding the cost of suture anchors. This anchorless double-row triceps tendon repair can be considered as an acceptable alternative to a knotless anchor repair for triceps tendon ruptures.

  18. Composite Repair System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — GTL has developed an innovative composite repair methodology known as the Composite Repair System (CRS). In this phase I effort, CRS is being developed for the...

  19. About the Collision Repair Campaign

    Science.gov (United States)

    EPA developed the Collision Repair Campaign to focus on meaningful risk reduction in the Collision Repair source sector to complement ongoing community air toxics work and attain reductions at a faster rate.

  20. Vesicovaginal Fistula Repair During Pregnancy

    African Journals Online (AJOL)

    Vesicovaginal Fistula Repair During Pregnancy: A Case Report ... Abstract. We report a repair of Vesicovaginal fistula during pregnancy that was aimed at preventing another spontaneous ... practices that encourage teenage marriage and girl.