Sample records for morphometric ct study

  1. Experimental sharp force injuries to ribs: Multimodal morphological and geometric morphometric analyses using micro-CT, macro photography and SEM.

    Science.gov (United States)

    Komo, Larissa; Grassberger, Martin

    2018-07-01

    Tool marks on bones induced by knife blades can be analysed morphometrically in order to enable an allocation of the suspected "inflicting weapon" to the particular morphology of the bone lesions. Until now, geometric morphometrics has not been used to analyse the morphology of knife lesions on fleshed bones in detail. By using twelve experimental knives and a drop weight tower, stab/cut injuries were inflicted on untreated pig ribs. The morphology of the experimentally produced lesions was subsequently recorded with three imaging techniques (μCT, macro photography and SEM) and analysed with different morphometric software (Amira, tps and Morpheus). Based on the measured distances between the walls of the kerf marks, which corresponded to the thickness of the blade, one could conclude to the respective blade thickness with a deviation of max. ±0.35mm and match the injuries to the knives. With subsequent reanalysis after maceration, an average shrinkage factor up to 8.6% was observed. Among the three imaging techniques used in this study, μCT was the most accurate and efficient technique, particularly because it represented the only non-destructive modality to document injuries without maceration, even though μCT is more expensive and time-consuming as well as less accessible than a macro SLR-camera or a SEM. For optimal characterizations of the blades' and kerfs' shapes the software tps proofed to be the best choice. Accordingly, geometric morphometrics could serve as a tool in forensic investigations concerning kerf marks. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  3. A morphometric CT study of Down's syndrome showing small posterior fossa and calcification of basal ganglia

    International Nuclear Information System (INIS)

    Ieshima, A.; Yoshino, K.; Takashima, S.; Takeshita, K.; Kisa, T.

    1984-01-01

    We report characteristic and morphometric changes of cranial computed tomography (CT) with increasing age in 56 patients with Down's syndrome aged from 0 month to 37 years. Patients were compared with 142 normal controls aged 0 to 59 years. Width of ventricles, Sylvian fissures, posterior fossa, pons and cisterna magna were measured on CT. The incidences of the cavum septi pellucidi, cavum vergae and cavum veli interpositi and high density in the basal ganglia were examined. There was high incidence (10.7%) of bilateral calcification of basal ganglia in Down's syndrome, although that of pineal body and choroid plexus calcification was similar in Down's syndrome and controls. Basal ganglia calcification is more frequently seen in young Down's syndrome and may be related to the premature aging characteristic of Down's syndrome. The CT in Down's syndrome showed relatively small posterior fossa, small cerebellum, small brain stem and relatively large Sylvian fissures in those under one year of age. There was a high frequency of midline cava and large cisterna magna. There were no significant atrophic changes on CT except after the fifth decade comparing with controls. (orig.)

  4. The use of maxillary sinus dimensions in gender determination: a thin-slice multidetector computed tomography assisted morphometric study.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Inci, Ercan; Hocaoglu, Elif; Sayin, Ibrahim; Kayhan, Fatma Tulin; Can, Ismail Ozgur

    2014-05-01

    Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. In the present study, morphometric analysis of maxillary sinuses was performed to determine gender. For morphometric analysis, coronal and axial paranasal sinus computed tomography (CT) scan with 1-mm slice thickness was used. For this study, 140 subjects (70 women and 70 men) were enrolled (age ranged between 18 and 63). The size of each subject's maxillary sinuses was measured in anteroposterior, transverse, cephalocaudal, and volume directions. In each measurement, the size of the maxillary sinus is significantly small in female gender (P discrimination analysis was performed, the accuracy rate was detected as 80% for women and 74.3% for men with an overall rate of 77.15%. With the use of 1-mm slice thickness CT, morphometric analysis of maxillary sinuses will be helpful for gender determination.

  5. Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Wouters, Johan; Vercauteren, Tom; De Gersem, Werner; Duprez, Fréderic; De Neve, Wilfried; Van Hoof, Tom

    2015-01-01

    Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result

  6. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    International Nuclear Information System (INIS)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da; Alves, Jose Marcos

    2014-01-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  7. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da, E-mail: alhakme@sc.usp.br [Universidade de Sao Paulo (EESC/FMRP/IQSC/USP), Sao Carlos, SP (Brazil); Alves, Jose Marcos [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Departamento de Engenharia Eletrica e Computacao

    2014-07-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  8. Study of bony trabecular characteristics using bone morphometry and micro-CT

    International Nuclear Information System (INIS)

    Song, Young Han; Lee, Wan; Lee, Chang Jin; Ji, Jung Hyun; Lee, Byung Do

    2007-01-01

    The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Twenty-one female (Newzeland, about 16 weeks old, 2.9-3.4 kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Basline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1,2,3,5,6 months respectively, BMD tests were performed on the proximal on the proximal femur by using PIXImus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custom computer program and 2D / 3D bone structure analysis by micro-CT (Skyscan1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD. BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp. Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change

  9. Automation process for morphometric analysis of volumetric CT data from pulmonary vasculature in rats.

    Science.gov (United States)

    Shingrani, Rahul; Krenz, Gary; Molthen, Robert

    2010-01-01

    With advances in medical imaging scanners, it has become commonplace to generate large multidimensional datasets. These datasets require tools for a rapid, thorough analysis. To address this need, we have developed an automated algorithm for morphometric analysis incorporating A Visualization Workshop computational and image processing libraries for three-dimensional segmentation, vascular tree generation and structural hierarchical ordering with a two-stage numeric optimization procedure for estimating vessel diameters. We combine this new technique with our mathematical models of pulmonary vascular morphology to quantify structural and functional attributes of lung arterial trees. Our physiological studies require repeated measurements of vascular structure to determine differences in vessel biomechanical properties between animal models of pulmonary disease. Automation provides many advantages including significantly improved speed and minimized operator interaction and biasing. The results are validated by comparison with previously published rat pulmonary arterial micro-CT data analysis techniques, in which vessels were manually mapped and measured using intense operator intervention. Published by Elsevier Ireland Ltd.

  10. Morphometric anatomical and CT study of the human adult sacroiliac region.

    Science.gov (United States)

    Postacchini, Roberto; Trasimeni, Guido; Ripani, Francesca; Sessa, Pasquale; Perotti, Stefano; Postacchini, Franco

    2017-01-01

    To identify and describe the morphometry and CT features of the articular and extra-articular portions of the sacroiliac region. The resulting knowledge might help to avoid complications in sacroiliac joint (SIJ) fusion. We analyzed 102 dry hemi-sacra, 80 ilia, and 10 intact pelves and assessed the pelvic computerized tomography (CT) scans of 90 patients, who underwent the examination for conditions not involving the pelvis. We assessed both the posterior aspect of sacrum with regard to the depressions located externally to the lateral sacral crest at the level of the proximal three sacral vertebrae and the posteroinferior aspect of ilium. Coronal and axial CT scans of the SIJ of patients were obtained and the joint space was measured. On each side, the sacrum exhibits three bone depressions, not described in anatomic textbooks or studies, facing the medial aspect of the posteroinferior ilium, not yet described in detail. Both structures are extra-articular portions situated posteriorly to the SIJ. Coronal CT scans of patients showing the first three sacral foramens and the interval between sacrum and ilium as a continuous space display only the S1 and S3 portions of SIJ, the intermediate portion being extra-articular. The S2 portion is visible on the most anterior coronal scan. Axial scans show articular and extra-articular portions and features improperly described as anatomic variations. Extra-articular portions of the sacroiliac region, not yet described exhaustively, have often been confused with SIJ. Coronal CT scans through the middle part of sacrum, the most used to evaluate degenerative and inflammatory conditions of SIJ, show articular and extra-articular portions of the region.

  11. Micro-computed tomography (μCT) as a novel method in ecotoxicology — determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    International Nuclear Information System (INIS)

    Brinkmann, Markus; Rizzo, Larissa Y.; Lammers, Twan; Gremse, Felix; Schiwy, Sabrina; Kiessling, Fabian; Hollert, Henner

    2016-01-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. - Highlights: • μCT was used for volumetric imaging sediment-exposed and unexposed rainbow trout • Liver volumes determined by μCT were highly correlated with liver weights. • The perfusion of organs in fish could also be studied by means of μCT. • It was shown that μCT is a useful tool in context of ecotoxicological research.

  12. Micro-computed tomography (μCT) as a novel method in ecotoxicology — determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    Energy Technology Data Exchange (ETDEWEB)

    Brinkmann, Markus, E-mail: markus.brinkmann@bio5.rwth-aachen.de [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Rizzo, Larissa Y.; Lammers, Twan; Gremse, Felix [Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen (Germany); Schiwy, Sabrina [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Kiessling, Fabian [Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen (Germany); Hollert, Henner, E-mail: henner.hollert@bio5.rwth-aachen.de [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); College of Resources and Environmental Science, Chongqing University, 1 Tiansheng Road Beibei, Chongqing 400715 (China); College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, 1239 Siping Road, Shanghai (China); State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University (China)

    2016-02-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. - Highlights: • μCT was used for volumetric imaging sediment-exposed and unexposed rainbow trout • Liver volumes determined by μCT were highly correlated with liver weights. • The perfusion of organs in fish could also be studied by means of μCT. • It was shown that μCT is a useful tool in context of ecotoxicological research.

  13. Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2010-09-01

    The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r

  14. Micro-computed tomography (μCT) as a novel method in ecotoxicology--determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss).

    Science.gov (United States)

    Brinkmann, Markus; Rizzo, Larissa Y; Lammers, Twan; Gremse, Felix; Schiwy, Sabrina; Kiessling, Fabian; Hollert, Henner

    2016-02-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography.

    Science.gov (United States)

    Song, Jin Wook; Cha, Jung Yul; Bechtold, Till Edward; Park, Young Chel

    2013-01-01

    To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro-computed tomography (micro-CT) for bone morphometric analysis. A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. BIC values from micro-CT analysis decreased when the PSD increased (P micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P micro-CT, at least 5 PSD from the metal implant surface is needed.

  16. Morphometric study of Euchiton (Gnaphalieae: Asteraceae)

    NARCIS (Netherlands)

    Flann, C.M.

    2010-01-01

    A morphometric study was undertaken to survey taxa in the genus Euchiton Cass., distributed across Australia, New Zealand and South-east Asia. Phenetic analyses of herbarium specimens showed several taxa to be well delimited, including E. brassii (Mattf.) Anderb., E. breviscapus (Mattf.) Anderb., E.

  17. A MORPHOMETRIC STUDY OF THE SELLA TURCICA; GENDER EFFECT

    OpenAIRE

    Ashraf Mohamed Elsayed Ali SAKRAN *1, Mohammad Afzal KHAN 2, Faris Mohammed Nour ALTAF 3, Hassan Elsiddig Hassan FARAGALLA 4, Amal Yousif Ahmed Elhaj MUSTAFA 5, Muhammad Mazhar HIJAZI 6, Rayan Abdulshakur NIYAZI 7, Abrar Jamal TAWAKUL 8, Abeer Zubair MALEBARI 9, Amal AbdulAziz SALEM 10.

    2015-01-01

    Background and objective: Precise anatomical knowledge of the sella turcica is important for neurologists and surgeons operating in the region of cavernous sinus or the surrounding structures. The current study was undertaken to record normal morphometric parameters for future reference and to determine if there is any significance difference in the sella turcica morphometry regarding the gender. Methodology: A Morphometric analysis of the Sella Turcica and structures in vicinity were done...

  18. Variability of morphometric parameters of human trabecular tissue from coxo-arthritis and osteoporotic samples

    Directory of Open Access Journals (Sweden)

    Franco Marinozzi

    2012-01-01

    Full Text Available Morphometric and architectural bone parameters change in diseases such as osteoarthritis and osteoporosis. The mechanical strength of bone is primarily influenced by bone quantity and quality. Bone quality is defined by parameters such as trabecular thickness, trabecular separation, trabecular density and degree of anisotropy that describe the micro-architectural structure of bone. Recently, many studies have validated microtomography as a valuable investigative technique to assess bone morphometry, thanks to micro-CT non-destructive, non-invasive and reliability features, in comparison to traditional techniques such as histology. The aim of this study is the analysis by micro-computed tomography of six specimens, extracted from patients affected by osteoarthritis and osteoporosis, in order to observe the tridimensional structure and calculate several morphometric parameters.

  19. Alveolar bone healing in rats: micro-CT, immunohistochemical and molecular analysis

    Directory of Open Access Journals (Sweden)

    Jaqueline Suemi HASSUMI

    2018-06-01

    Full Text Available Abstract Alveolar bone healing after upper incisor extraction in rats is a classical model of preclinical studies. The underlying morphometric, cellular and molecular mechanism, however, remains imprecise in a unique study. Objectives The aim of this study was therefore to characterize the alveolar bone healing after upper incisor extraction in rats by micro computed tomographic (Micro-CT, immunohistochemical and real-time polymerase chain reaction (RT-PCR analysis. Material and Methods Thirty animals (Rattus norvegicus, Albinus Wistar were divided into three groups after upper incisors extraction at 7, 14, and 28 days. Micro-CT was evaluated based on the morphometric parameters. Subsequently, the histological analyses and immunostaining of osteoprotegerin (OPG, receptor activator of nuclear kappa B ligand (RANKL and tartrate resistant acid phosphate (TRAP was performed. In addition, RT-PCR analyses of OPG, RANKL, the runt-related transcription factor 2 (RUNX2, osteocalcin (OC, osteopontin (OPN, osterix (OST and receptor activator of nuclear kappa B (RANK were performed to determine the expression of these proteins in the alveolar bone healing. Results Micro-CT: The morphometric parameters of bone volume and trabecular thickness progressively increased over time. Consequently, a gradual decrease in trabecular separation, trabecular space and total bone porosity was observed. Immunohistochemical: There were no differences statistically significant between the positive labeling for OPG, RANKL and TRAP in the different periods. RT-PCR: At 28 days, there was a significant increase in OPG expression, while RANKL expression and the RANKL/OPG ratio both decreased over time. Conclusion Micro-CT showed the newly formed bone had favorable morphometric characteristics of quality and quantity. Beyond the RUNX2, OC, OPN, OST, and RANK proteins expressed in the alveolar bone healing, OPG and RANKL activity showed to be essential for activation of basic

  20. STUDY OF MORPHOMETRIC CHANGES OF FOETAL STOMACH

    Directory of Open Access Journals (Sweden)

    Mohammed Aneesur Rahman

    2017-07-01

    Full Text Available BACKGROUND Interest in human development is very widespread largely because of the curiosity about our beginnings and desire to improve the quality of life. Understanding of the processes involved in the formation of various organs and systems has unrevealed most cryptic secrets of the nature. Human development begins at fertilisation when a male gamete or sperm unites with a female gamete or oocyte to form a single cell, a zygote. With the formation of zygote (single-celled stage, foetal development begins. The aim of the study is to- 1 Study the morphometric parameters of foetal stomach at various gestational ages. 2 Compare these observations with the previous studies. MATERIALS AND METHODS Present work was the cross-sectional study carried out in the Department of Anatomy in collaboration with the Department of Obstetrics and Gynaecology at SRTRGMC and Hospital, Ambajogai Dist., Beed, Maharashtra. For this, approval of Institutional Ethical Committee was taken. 30 aborted human foetuses of different age groups ranging from 12 to 36 weeks of fertilisation were taken from the Department of OB-GYN. Foetuses were preserved by using 10% formalin. Age of foetuses were determined by crown-rump length and history given by mother. Foetuses were dissected after preservation for 15 days and morphometric studies were done on stomach. RESULTS Various quantitative parameters like weight of foetus, crown-rump length, total length of stomach, weight of stomach, length of greater curvature, lesser curvature, width of cardia and width of pylorus were used. For the purpose of study and comparison with other researchers, the foetuses were divided into 3 groups. Morphometric changes were observed in different groups and compared with previous studies. CONCLUSION With the increase in the body weight, crown-rump length and gestational age of the foetus, there is gradual increase on various parameters of stomach.

  1. Climatic effects on the nasal complex: a CT imaging, comparative anatomical, and morphometric investigation of Macaca mulatta and Macaca fascicularis.

    Science.gov (United States)

    Márquez, Samuel; Laitman, Jeffrey T

    2008-11-01

    Previous studies exploring the effects of climate on the nasal region have largely focused on external craniofacial linear parameters, using dry crania of modern human populations. This investigation augments traditional craniofacial morphometrics with internal linear and volumetric measures of the anatomic units comprising the nasal complex (i.e., internal nasal cavity depth, maxillary sinus volumes). The study focuses on macaques (i.e., Macaca mulatta and Macaca fascicularis) living at high and low altitudes, rather than on humans, since the short residency of migratory human populations may preclude using them as reliable models to test the long-term relationship of climate to nasal morphology. It is hypothesized that there will be significant differences in nasal complex morphology among macaques inhabiting different climates. This study integrated three different approaches: CT imaging, comparative anatomy, and morphometrics-in an effort to better understand the morphological structure and adaptive nature of the nasal complex. Results showed statistically significant differences when subsets of splanchnocranial and neurocranial variables were regressed against total maxillary sinus volume for particular taxa. For example, basion-hormion was significant for M. fascicularis, whereas choanal dimensions were significant only for M. mulatta. Both taxa revealed strong correlation between sinus volume and prosthion to staphylion distance, which essentially represents the length of the nasal cavity floor-and is by extension an indicator of the air conditioning capacity of the nasal region. These results clearly show that climatic effects play a major role in shaping the anatomy of the nasal complex in closely related species. The major influence upon these differing structures appears to be related to respiratory-related adaptations subserving differing climatic factors. In addition, the interdependence of the paranasal sinuses with other parts of the complex strongly

  2. Microtomographic and morphometric characterization of a bioceramic bone substitute in dental implantology

    Directory of Open Access Journals (Sweden)

    Deborah Meleo

    2012-01-01

    Full Text Available In recent years, bone tissue regeneration studies have led to a deeper knowledge of chemical and structural features of the best biomaterials to be used as replacements for lost bone structures, with the autologus bone still today the only graft material able to ostegenerate, osteinduct and/or osteoconduct. The difficulties of the small available amount of autologus bone, together with morbidity of a second surgical operation on the same patient, have been overcome using both synthetic and biologic substitute bones. The possibility of investigating morphometric characteristics of substitute bones makes it possible to evaluate the predictability of regenerative processes and, so far, a range of different methods have been used for the purpose. X-ray microtomography (micro-CT is a miniaturized form of conventional tomography, able to analyze the internal structure of small objects, performing three-dimensional images with high spatial resolution (<10 micron pixel size. For a correct analysis, samples need not be altered or treated in any way, as micro-CT is a non-invasive and non-destructive technique. It shows promising results in biomaterial studies and tissue engineering. This work shows the potential applications of this microtomographic technique by means of an in vitro analysis system, in characterizing morphometric features of human bone tissue, and contributes to the use of this technique in studies concerning biomaterials and bioscaffolds inserted in bone tissue.

  3. Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

    Science.gov (United States)

    Qian, Li-Xiong; Hao, Ding-Jun; He, Bao-Rong; Jiang, Yong-Hong

    2013-05-01

    To quantify the dimensions of the atlas pedicles and to analyze the relationship between extra medullary height (EMH) with intra medullary height (IMH) of the atlas pedicle. The images of the patients who had CT scanning and three-dimensional (3D) reconstruction involving atlantoaxial complex between June 2011 and April 2012 and meet our inclusion criteria were studied retrospectively. After reformatting the original images, the EMH and IMH of the atlas pedicles were measured. Extra medullary height and IMH were, respectively, 4.83 ± 1.13 and 1.29 ± 1.10 mm for males and 3.75 ± 0.93 and 0.60 ± 0.83 mm for females, with statistical difference (P atlas pedicles were measured by using CT images of the atlas, providing anatomic parameters for surgery. They showed a certain correlation but with a high variability. C1 pedicle screw fixation was well performed when the medullary canal was ≥1 mm, but the surgical procedure should be careful when it was between 0 and 1 mm, and avoided when there was no medullary canal in the atlas pedicle! So 3D CT reconstruction should be conducted to obtain data and establish individualized fixation strategy preoperatively.

  4. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  5. MicroCT Scan in paleobiology: application to the study of dental tissues

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, M.; Casali, F. E-mail: casali@bo.infn.it; Romani, D.; Bondioli, L.; Macchiarelli, R.; Rook, L

    2004-01-01

    State of the art in paleoanthropological and paleoprimatological research foresees the use of advanced non-destructive investigative approaches. Microcomputed tomography (microCT) is a fundamental tool, since it offers the opportunity to get high quality morphological information with high spatial resolution. We carried out the set-up of an experimental microCT system able to examine paleobiological samples. The equipment can operate on small objects (size up to 3 cm) with a nominal spatial resolution of 30 {mu}m, allowing their 3D volume reconstruction and morphometric analysis. This approach represents a forefront technique in paleobiological studies, successfully employed only in a limited number of advanced research centers. A specific program of microCT analysis has been planned on a sample of human and non-human fossil primate dentitions, in order to assess the specific nature of a number of tooth lesions (e.g. caries versus abrasion). This currently in progress experimental activity represents the first step for the set-up of a research center specifically devoted to the realization of advanced studies in the field of archaeo-paleobiology.

  6. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  7. Watershed-based Morphometric Analysis: A Review

    Science.gov (United States)

    Sukristiyanti, S.; Maria, R.; Lestiana, H.

    2018-02-01

    Drainage basin/watershed analysis based on morphometric parameters is very important for watershed planning. Morphometric analysis of watershed is the best method to identify the relationship of various aspects in the area. Despite many technical papers were dealt with in this area of study, there is no particular standard classification and implication of each parameter. It is very confusing to evaluate a value of every morphometric parameter. This paper deals with the meaning of values of the various morphometric parameters, with adequate contextual information. A critical review is presented on each classification, the range of values, and their implications. Besides classification and its impact, the authors also concern about the quality of input data, either in data preparation or scale/the detail level of mapping. This review paper hopefully can give a comprehensive explanation to assist the upcoming research dealing with morphometric analysis.

  8. Increased Insular Cortical Thickness Associated With Symptom Severity in Male Youths With Internet Gaming Disorder: A Surface-Based Morphometric Study

    Science.gov (United States)

    Wang, Shuai; Liu, Jing; Tian, Lin; Chen, Limin; Wang, Jun; Tang, Qunfeng; Zhang, Fuquan; Zhou, Zhenhe

    2018-01-01

    With the rising increase in Internet-usage, Internet gaming disorder (IGD) has gained massive attention worldwide. However, detailed cerebral morphological changes remain unclear in youths with IGD. In the current study, our aim was to investigate cortical morphology and further explore the relationship between the cortical morphology and symptom severity in male youths with IGD. Forty-eight male youths with IGD and 32 age- and education-matched normal controls received magnetic resonance imaging scans. We employed a recently proposed surface-based morphometric approach for the measurement of cortical thickness (CT). We found that youths with IGD showed increased CT in the bilateral insulae and the right inferior temporal gyrus. Moreover, significantly decreased CT were found in several brain areas in youths with IGD, including the bilateral banks of the superior temporal sulci, the right inferior parietal cortex, the right precuneus, the right precentral gyrus, and the left middle temporal gyrus. Additionally, youths with IGD demonstrated a significantly positive correlation between the left insular CT and symptom severity. Our data provide evidence for the finding of abnormal CT in distributed cerebral areas and support the notion that altered structural abnormalities observed in substance addiction are also manifested in IGD. Such information extends current knowledge about IGD-related brain reorganization and could help future efforts in identifying the role of insula in the disorder. PMID:29666588

  9. Increased Insular Cortical Thickness Associated With Symptom Severity in Male Youths With Internet Gaming Disorder: A Surface-Based Morphometric Study

    Directory of Open Access Journals (Sweden)

    Shuai Wang

    2018-04-01

    Full Text Available With the rising increase in Internet-usage, Internet gaming disorder (IGD has gained massive attention worldwide. However, detailed cerebral morphological changes remain unclear in youths with IGD. In the current study, our aim was to investigate cortical morphology and further explore the relationship between the cortical morphology and symptom severity in male youths with IGD. Forty-eight male youths with IGD and 32 age- and education-matched normal controls received magnetic resonance imaging scans. We employed a recently proposed surface-based morphometric approach for the measurement of cortical thickness (CT. We found that youths with IGD showed increased CT in the bilateral insulae and the right inferior temporal gyrus. Moreover, significantly decreased CT were found in several brain areas in youths with IGD, including the bilateral banks of the superior temporal sulci, the right inferior parietal cortex, the right precuneus, the right precentral gyrus, and the left middle temporal gyrus. Additionally, youths with IGD demonstrated a significantly positive correlation between the left insular CT and symptom severity. Our data provide evidence for the finding of abnormal CT in distributed cerebral areas and support the notion that altered structural abnormalities observed in substance addiction are also manifested in IGD. Such information extends current knowledge about IGD-related brain reorganization and could help future efforts in identifying the role of insula in the disorder.

  10. External morphometric study of hatchery reared mahseer ( Tor ...

    African Journals Online (AJOL)

    Different samples of Mahseer (Tor putitora) were examined for the study of external morphometric characters of the fish. Slopes of log transformed data were used for comparison with an isometric slopes (b=1, b= 0.33 or b= 3). Relationships between wet body weight and external body parts lengths showed that increasing ...

  11. Morphometric studies on a part of Central Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Kodagali, V.N.

    Morphometric and slope angle studies carried out on a part of Indian Ocean Basin have shown that gentle slope angle ranges dominate, 92% of the area represented by 0-3 degrees slopes. Young's hypothesis of log-normal distribution of slope angle...

  12. Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

    Science.gov (United States)

    Picard de Muller, Gaël; Ait-Belkacem, Rima; Bonnel, David; Longuespée, Rémi; Stauber, Jonathan

    2017-12-01

    Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric - number of objects and total surface - information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. [Figure not available: see fulltext.

  13. Morphometric Studies Of The Cerebellum And Forebrain Of The ...

    African Journals Online (AJOL)

    Morphometric studies were undertaken using the brains of six African giant rats. The mean of weights and lengths (tip of the olfactory bulb to the caudal border of the cerebellum) were observed tobe 4.88 0.183g and 4.40 0.193g, respectively. Similarly, the mean weight and length of the cerebellum and the forebrain ...

  14. The effect of morphometric atlas selection on multi-atlas-based automatic brachial plexus segmentation

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Wouters, Johan; Vercauteren, Tom; De Gersem, Werner; Achten, Eric; De Neve, Wilfried; Van Hoof, Tom

    2015-01-01

    The present study aimed to measure the effect of a morphometric atlas selection strategy on the accuracy of multi-atlas-based BP autosegmentation using the commercially available software package ADMIRE® and to determine the optimal number of selected atlases to use. Autosegmentation accuracy was measured by comparing all generated automatic BP segmentations with anatomically validated gold standard segmentations that were developed using cadavers. Twelve cadaver computed tomography (CT) atlases were included in the study. One atlas was selected as a patient in ADMIRE®, and multi-atlas-based BP autosegmentation was first performed with a group of morphometrically preselected atlases. In this group, the atlases were selected on the basis of similarity in the shoulder protraction position with the patient. The number of selected atlases used started at two and increased up to eight. Subsequently, a group of randomly chosen, non-selected atlases were taken. In this second group, every possible combination of 2 to 8 random atlases was used for multi-atlas-based BP autosegmentation. For both groups, the average Dice similarity coefficient (DSC), Jaccard index (JI) and Inclusion index (INI) were calculated, measuring the similarity of the generated automatic BP segmentations and the gold standard segmentation. Similarity indices of both groups were compared using an independent sample t-test, and the optimal number of selected atlases was investigated using an equivalence trial. For each number of atlases, average similarity indices of the morphometrically selected atlas group were significantly higher than the random group (p < 0,05). In this study, the highest similarity indices were achieved using multi-atlas autosegmentation with 6 selected atlases (average DSC = 0,598; average JI = 0,434; average INI = 0,733). Morphometric atlas selection on the basis of the protraction position of the patient significantly improves multi-atlas-based BP autosegmentation accuracy

  15. MORPHOMETRICAL PARAMETERS OF GUT MICROFLORA IN HUMAN VOLUNTEERS

    NARCIS (Netherlands)

    Wilkinson, M.H.F.; Meijer, B.C

    1991-01-01

    The morphology of faecal microflora of nine healthy human volunteers was studied by digital image analysis of microscopic slides. Weekly specimens were collected during an 8-week period. Seven morphometrical parameters were derived: the means and medians of components 1, 2 and 3, and morphometrical

  16. Morphometric analysis of the infraorbital foramen, canal and groove using cone beam CT: considerations for creating artificial organs.

    Science.gov (United States)

    Orhan, Kaan; Misirli, Melis; Aksoy, Secil; Seki, Umut; Hincal, Evren; Ormeci, Tugrul; Arslan, Ahmet

    2016-01-01

    The aim of this study was to examine the anatomy and variations of the infraorbital foramen and its surroundings via morphometric measurements using cone beam computed tomography (CBCT) scans derived from a 3D volumetric rendering program. 354 sides of CBCT scans from 177 patients were examined in this study. DICOM data from these images were exported to Maxilim® software in order to generate 3D surface models. The morphometric measurements were done for infraorbital foramen (IOF), infraorbital groove (IOG) and infraorbital canal (IOC). All images were evaluated by 1 radiologist. To assess intra-observer reliability, the Wilcoxon matched-pairs signed rank test was used. Differences between sex, side, age and measurements were evaluated using chi-square and paired t-test and measurements were evaluated using 1-way ANOVA tests. Differences were considered significant when p0.05). No significant difference was found according to age groups (p>0.05). These results provide detailed knowledge of the anatomical characteristics in this particular area. CBCT imaging with lower radiation dose and thin slices can be a powerful tool for anesthesia procedures like infra orbital nerve blocks, for surgical approaches like osteotomies and neurectomies and also for generating artificial prostheses.

  17. Morphometric and Histological Study of Osteophytes in Human Cadaveric Lumbar Vertebrae

    OpenAIRE

    Ashwini Aithal Padur; Naveen Kumar; Swamy Ravindra Shanthakumar; Arijit Bishnu

    2017-01-01

    Introduction: Osteophytes are bony outgrowth on the vertebral column. Its prevalence in the lumbar region and clinical importance mandates to conduct a detailed study of lumbar osteophytes in the cadaveric vertebral column. Aim: The present study was conducted to study the detailed features of lumbar osteophytes and document its prevalence, morphometric and histological structure. Materials and Methods: This was an observational study in which frequency of occurrence of lumbar osteophyt...

  18. Re-description and Reassignment of the Damselfish Abudefduf luridus (Cuvier, 1830) Using Both Traditional and Geometric Morphometric Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W. James [Washington State Univ., Pullman, WA (United States); Albertson, R Craig [Univ. of Massachusetts, Amherst, MA (United States); Jacob, Rick E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westneat, Mark W. [Field Museum of Natural History, Chicago, IL (United States)

    2014-12-01

    Here we present a re-description of Abudefduf luridus and reassign it to the genus Similiparma. We supplement traditional diagnoses and descriptions of this species with quantitative anatomical data collected from a family-wide geometric morphometric analysis of head morphology (44 species representing all 30 damselfish genera) and data from cranial micro-CT scans of fishes in the genus Similiparma. The use of geometric morphometric analyses (and other methods of shape analysis) permits detailed comparisons between the morphology of specific taxa and the anatomical diversity that has arisen in an entire lineage. This provides a particularly useful supplement to traditional description methods and we recommend the use of such techniques by systematists. Similiparma and its close relatives constitute a branch of the damselfish phylogenetic tree that predominantly inhabits rocky reefs in the Atlantic and Eastern Pacific, as opposed to the more commonly studied damselfishes that constitute a large portion of the ichthyofauna on all coral-reef communities.

  19. A web-system of virtual morphometric globes

    Science.gov (United States)

    Florinsky, Igor; Garov, Andrei; Karachevtseva, Irina

    2017-04-01

    represents morphometric models with the resolution of 15'. In the final version of the system, we plan to implement a multiscale 3D visualization for models of 17 morphometric variables with the resolution from 15' to 30". The web-system of virtual morphometric globes is designed as a separate unit of a 3D web GIS for storage, processing, and access to planetary data [2], which is currently developed as an extension of an existing 2D web GIS (http://cartsrv.mexlab.ru/geoportal). Free, real-time web access to the system of virtual globes will be provided. The testing version of the system is available at: http://cartsrv.mexlab.ru/virtualglobe. The study is supported by the Russian Foundation for Basic Research, grant 15-07-02484. References 1. Florinsky, I.V., 2016. Digital Terrain Analysis in Soil Science and Geology. 2nd ed. Academic Press, Amsterdam, 486 p. 2. Garov, A.S., Karachevtseva, I.P., Matveev, E.V., Zubarev, A.E., and Florinsky, I.V., 2016. Development of a heterogenic distributed environment for spatial data processing using cloud technologies. International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 41(B4): 385-390.

  20. Morphometric Characterization of Small Cell Lymphocytic Lymphoma

    Directory of Open Access Journals (Sweden)

    Chisoi Anca

    2014-11-01

    Full Text Available The morphometry in histopathology is used to characterize cell populations belonging to different tissues and to identify differences in their parameters with prognostic implications. To achieve morphometric examination were selected 6 of 24 cases identified as small cell lymphocytic lymphoma. For each case analysis was done on five fields, for each field measuring the parameters of 20 cells. The studied parameters were for cytoplasm: cytoplasmic area, maximum and minimum cytoplasmic diameter, cytoplasmic perimeter; for nucleus were measured: nuclear area, minimum and maximum nuclear diameter, nuclear perimeter, nuclear contour index, nuclear ellipticity index, nuclear irregularity index. Also the nucleocytoplasmic ratio was calculated in all studied cases. Small cell lymphocytic lymphoma is characterized in morphometric terms having a small cytoplasmic area (average 29.206 and also a small nuclear area (mean 28.939 having a nucleo-cytoplasmic ratio appearance suggestive for adult lymphocyte. A nuclear contour index small value (3.946, ellipticity index value also small (3.521 and small nuclear irregularity index (3.965. Standard deviations, in any of the studied morphometric categories, is around or below 1 suggesting monomorphic cell appearance. These morphometric and microscopic features characterized mainly by a small population of adult lymphocytes, monomorphic, with rounded hipercromic nuclei, dense chromatin, support the framing into indolent lymphoma group in terms of clinical outcome.

  1. Digital Morphometrics: A New Upper Airway Phenotyping Paradigm in OSA.

    Science.gov (United States)

    Schwab, Richard J; Leinwand, Sarah E; Bearn, Cary B; Maislin, Greg; Rao, Ramya Bhat; Nagaraja, Adithya; Wang, Stephen; Keenan, Brendan T

    2017-08-01

    OSA is associated with changes in pharyngeal anatomy. The goal of this study was to objectively and reproducibly quantify pharyngeal anatomy by using digital morphometrics based on a laser ruler and to assess differences between subjects with OSA and control subjects and associations with the apnea-hypopnea index (AHI). To the best of our knowledge, this study is the first to use digital morphometrics to quantify intraoral risk factors for OSA. Digital photographs were obtained by using an intraoral laser ruler and digital camera in 318 control subjects (mean AHI, 4.2 events/hour) and 542 subjects with OSA (mean AHI, 39.2 events/hour). The digital morphometric paradigm was validated and reproducible over time and camera distances. A larger modified Mallampati score and having a nonvisible airway were associated with a higher AHI, both unadjusted (P digital morphometrics is an accurate, high-throughput, and noninvasive technique to identify anatomic OSA risk factors. Morphometrics may also provide a more reproducible and standardized measurement of the Mallampati score. Digital morphometrics represent an efficient and cost-effective method of examining intraoral crowding and tongue size when examining large populations, genetics, or screening for OSA. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  2. Morphometric Analysis of Didessa River Catchment in Blue Nile ...

    African Journals Online (AJOL)

    Morphometric Analysis of Didessa River Catchment in Blue Nile Basin, Western Ethiopia. ... In the present paper an attempt has been made to study the morphometric characteristics of Didessa ... Stream networks and watersheds were delineated in ArcGIS 10.1 software environment by utilizing ... HOW TO USE AJOL.

  3. 3D osteocyte lacunar morphometric properties and distributions in human femoral cortical bone using synchrotron radiation micro-CT images.

    Science.gov (United States)

    Dong, Pei; Haupert, Sylvain; Hesse, Bernhard; Langer, Max; Gouttenoire, Pierre-Jean; Bousson, Valérie; Peyrin, Françoise

    2014-03-01

    Osteocytes, the most numerous bone cells, are thought to be actively involved in the bone modeling and remodeling processes. The morphology of osteocyte is hypothesized to adapt according to the physiological mechanical loading. Three-dimensional micro-CT has recently been used to study osteocyte lacunae. In this work, we proposed a computationally efficient and validated automated image analysis method to quantify the 3D shape descriptors of osteocyte lacunae and their distribution in human femurs. Thirteen samples were imaged using Synchrotron Radiation (SR) micro-CT at ID19 of the ESRF with 1.4μm isotropic voxel resolution. With a field of view of about 2.9×2.9×1.4mm(3), the 3D images include several tens of thousands of osteocyte lacunae. We designed an automated quantification method to segment and extract 3D cell descriptors from osteocyte lacunae. An image moment-based approach was used to calculate the volume, length, width, height and anisotropy of each osteocyte lacuna. We employed a fast algorithm to further efficiently calculate the surface area, the Euler number and the structure model index (SMI) of each lacuna. We also introduced the 3D lacunar density map to directly visualize the lacunar density variation over a large field of view. We reported the lacunar morphometric properties and distributions as well as cortical bone histomorphometric indices on the 13 bone samples. The mean volume and surface were found to be 409.5±149.7μm(3) and 336.2±94.5μm(2). The average dimensions were of 18.9±4.9μm in length, 9.2±2.1μm in width and 4.8±1.1μm in depth. We found lacunar number density and six osteocyte lacunar descriptors, three axis lengths, two anisotropy ratios and SMI, that are significantly correlated to bone porosity at a same local region. The proposed method allowed an automatic and efficient direct 3D analysis of a large population of bone cells and is expected to provide reliable biological information for better understanding the

  4. Morphometrics applied to medical entomology.

    Science.gov (United States)

    Dujardin, Jean-Pierre

    2008-12-01

    Morphometrics underwent a revolution more than one decade ago. In the modern morphometrics, the estimate of size is now contained in a single variable reflecting variation in many directions, as many as there are landmarks under study, and shape is defined as their relative positions after correcting for size, position and orientation. With these informative data, and the corresponding software freely available to conduct complex analyses, significant biological and epidemiological features can be quantified more accurately. We discuss the evolutionary significance of the environmental impact on metric variability, mentioning the importance of concepts like genetic assimilation, genetic accommodation, and epigenetics. We provide examples of measuring the effect of selection on metric variation by comparing (unpublished) Qst values with corresponding (published) Fst. The primary needs of medical entomologists are to distinguish species, especially cryptic species, and to detect them where they are not expected. We explain how geometric morphometrics could apply to these questions, and where there are deficiencies preventing the approach from being utilized at its maximum potential. Medical entomologists in connection with control programs aim to identify isolated populations where the risk of reinfestation after treatment would be low ("biogeographical islands"). Identifying them can be obtained from estimating the number of migrants per generation. Direct assessment of movement remains the most valid approach, but it scores active movement only. Genetic methods estimating gene flow levels among interbreeding populations are commonly used, but gene flow does not necessarily mean the current flow of migrants. Methods using the morphometric variation are neither suited to evaluate gene flow, nor are they adapted to estimate the flow of migrants. They may provide, however, the information needed to create a preliminary map pointing to relevant areas where one could

  5. Changes in mast cells during acute radiation sickness(a morphometric study)

    International Nuclear Information System (INIS)

    Datsenko, A.V.; Shikhodyrov, V.V.

    1985-01-01

    Changes in the morphometric parameters of rat mast cells during acute radiation sickness have been studied. The most significant deviation of the quantitative indices of mast cells from the control values were noted at the height of the bone-marrow, at the terminal stage of the intestinal, and during the first few hours of the cerebral forms of acute radiation sickness

  6. Morphometric and Histological Study of Osteophytes in Human Cadaveric Lumbar Vertebrae

    Directory of Open Access Journals (Sweden)

    Ashwini Aithal Padur

    2017-10-01

    Full Text Available Introduction: Osteophytes are bony outgrowth on the vertebral column. Its prevalence in the lumbar region and clinical importance mandates to conduct a detailed study of lumbar osteophytes in the cadaveric vertebral column. Aim: The present study was conducted to study the detailed features of lumbar osteophytes and document its prevalence, morphometric and histological structure. Materials and Methods: This was an observational study in which frequency of occurrence of lumbar osteophytes was studied in 40 cadaveric vertebral columns over a period of four years. The lumbar part of the vertebral columns was dissected and examined meticulously. The occurrence of lumbar osteophytes with their vertebral levels and morphometric measurements were recorded. A small excision of the osteophyte was processed histologically to study its microscopic details using routine Haematoxylin & Eosin stain. Results: Lumbar osteophytes were present in 4 specimens (10%. They were mostly found on the right side of the vertebral bodies. Histopathological examination of the osteophytes revealed degenerative osteophytic cartilage and fibrillation overlying the trabecular bone enclosing fatty marrow spaces containing haematopoietic elements. Conclusion: Lumbar osteophytes were found in 10% of the specimens studied and it is assumed that these cadaveric reports deserve further attention given their potential clinical implications. Knowledge regarding occurrence and incidence of osteophytes is essential for management of common degenerative changes of the vertebral column.

  7. Occipital plagiocephaly: deformation or lambdoid synostosis? I. morphometric analysis and results of unilateral lambdoid craniectomy

    International Nuclear Information System (INIS)

    Dias, M.S.; Klein, D.M.; Backstrom, J.W.

    1997-01-01

    Between 1987 and 1992, 30 infants aged 1.4-13 months (mean 7.3 months) underwent unilateral lambdoid strip craniectomy at the Children's Hospital of Buffalo for occipital plagiocephaly. Males outnumbered females (22:8) and right-sided occipital flattening was significantly more common than left-sided flattening (25:5). The deformity was noticed at an average age of 3.2 months; 16% of the infants had an asymmetry at birth. Positional preferences (a distinct tendency to lie preferentially on the back, in most cases with the head turned to the ipsilateral side) were described in 79% of infants for whom this information was available, and torticollis was present in 10%. Pre-and post-operative CT scans were analyzed using several morphometric measurements. Asymmetries were measured between the flattened and contralateral sides, both posteriorly and anteriorly, using a translucent grid placed over the CT slice showing maximum asymmetry. The average maximum asymmetry between the flattened and contralateral sides was 24% posteriorly and 16% anteriorly. Significant improvements were seen postoperatively, with both anterior and posterior asymmetries improving by an average of one third (p < 0.05). However, when compared with CT scans from a control group of infants without synostosis, the operated group showed persistent and significant asymmetries postoperatively. The morphometric measurements described allow an objective and reproducible means of assessing the results of various treatments for this disorders. The improvements following unilateral lambdoid craniectomy are difficult to interpret in isolation; we suggest that future efforts be directed toward similarly assessing the results of both nonoperative treatments such as positional changes and molding helmets, and more aggressive surgical treatments that have been advocated for this disorders. (authors)

  8. Reproducibility of morphometric X-ray absorptiometry

    International Nuclear Information System (INIS)

    Culton, N.; Pocock, N.

    1999-01-01

    Full text: Morphometric X-ray absorptiometry (MXA) using DXA is potentially a useful clinical tool which may provide additional vertebral fracture information with low radiation exposure. While morphometric analysis is semi-automated, operator intervention is crucial for the accurate positioning of the six data points quantifying the vertebral heights at the anterior, middle and posterior positions. Our study evaluated intra-operator reproducibility of MXA in an elderly patient population and assessed the effect of training and experience on vertebral height precision. Ten patients, with a mean lumbar T score of - 2.07, were studied. Images were processed by a trained operator who had initially only limited morphometric experience. The analysis of the data files were repeated at 2 and 6 weeks, during which time the operator had obtained further experience and training. The intra-operator precision of vertebral height measurements was calculated using the three separate combinations of paired analyses, and expressed as the coefficient of variation. This study confirms the importance of adequate training and attention to detail in MXA analysis. The data indicate that the precision of MXA is adequate for its use in the diagnosis of vertebral fractures, based on a 20% deformity criteria. Use of MXA for monitoring would require approximately an 8% change in vertebral heights to achieve statistical significance

  9. Morphometric analysis of llama (Lama glama) sperm head.

    Science.gov (United States)

    Casaretto, C; Lombardo, D M; Giuliano, S; Gambarotta, M; Carretero, M I; Miragaya, M H

    2012-05-01

    Llama production in Argentina has increased, as the international interest in breeding this type of animals has grown in the last years. Considering the great polymorphism that llama spermatozoa present at evaluation using light microscopy, the aim of this study was to objectively evaluate llama sperm head morphometry using digital morphometric analysis. Five ejaculates from each of eight males were obtained to evaluate morphometric parameters of 8000 sperm heads stained with Tinción 15(®). The following average results were obtained for each parameter: size parameters: area 20.09 μm(2), length 6.60 μm, width 4.14 μm, equivalent circle diameter 5.06 μm, curve length 5.79 μm and curve width 3.48 μm; boundary parameters: perimeter 18.54 μm and convex perimeter 17.34 μm; and shape parameters: roundness 1.28 and elongation 1.59. Morphometric parameters of sperm head were compared between ejaculates of the same male and between males. Significant differences between ejaculates of the same male were found for all parameters evaluated (P < 0.01). Significant differences between males were found for all morphometric parameters (P < 0.01) except for curve length, curve width and perimeter. The differences detected would indicate that there is not a single morphometric pattern for Lama glama sperm head, because parameter values cannot be standardised. © 2011 Blackwell Verlag GmbH.

  10. CT-based morphometric analysis of the occipital condyle: focus on occipital condyle screw insertion.

    Science.gov (United States)

    Zhou, Jinsong; Espinoza Orías, Alejandro A; Kang, Xia; He, Jade; Zhang, Zhihai; Inoue, Nozomu; An, Howard S

    2016-11-01

    OBJECTIVE The segmental occipital condyle screw (OCS) is an alternative fixation technique in occipitocervical fusion. A thorough morphological study of the occipital condyle (OC) is critical for OCS placement. The authors set out to introduce a more precise CT-based method for morphometric analysis of the OC as it pertains to the placement of the segmental OCS, and they describe a novel preoperative simulation method for screw placement. Two new clinically relevant parameters, the height available for the OCS and the warning depth, are proposed. METHODS CT data sets from 27 fresh-frozen human cadaveric occipitocervical spines were used. All measurements were performed using a commercially available 3D reconstruction software package. The length, width, and sagittal angle of the condyle were measured in the axial plane at the base of the OC. The height of the OC and the height available for the segmental OCS were measured in the reconstructed oblique sagittal plane, fitting the ideal trajectory of the OCS recommended in the literature. The placement of a 3.5-mm-diameter screw that had the longest length of bicortical purchase was simulated into the OC in the oblique sagittal plane, with the screw path not being blocked by the occiput and not violating the hypoglossal canal cranially or the atlantooccipital joint caudally. The length of the simulated screw was recorded. The warning depth was measured as the shortest distance from the entry point of the screw to the posterior border of the hypoglossal canal. RESULTS The mean length and width of the OC were found to be larger in males: 22.2 ± 1.7 mm and 12.1 ± 1.0 mm, respectively, overall (p < 0.0001 for both). The mean sagittal angle was 28.0° ± 4.9°. The height available for the OCS was significantly less than the height of the OC (6.2 ± 1.3 mm vs 9.4 ± 1.5 mm, p < 0.0001). The mean screw length (19.3 ± 1.9 mm) also presented significant sex-related differences: male greater than female (p = 0.0002). The

  11. Intestinal morphometric and biomechanical changes during aging in rats

    DEFF Research Database (Denmark)

    Zhao, Jingbo; Gregersen, Hans

    2015-01-01

    Background and aim: Previously we demonstrated pronounced morphometric and biomechanical remodeling in the rat intestine during physiological growth up to 32 weeks of age. The aim of the present study is to study intestinal geometric and biomechanical changes in aging rats. Materials and methods...... in the circumferential direction. In conclusion pronounced morphometric and biomechanical remodeling occurred in the rat intestine during aging. The observed changes likely reflect the changes of the physiological function of the intestine during ageing, similar to other tissues where function, mechanical loading......: Twenty-four male Wistar rats, aged from 6 to 22 months, were used in the study. The body weight and the wet weight per length of duodenal and ileal segments were measured at the termination of experiment. Morphometric data were obtained by measuring the wall thickness and wall cross-sectional area...

  12. Outline-based morphometrics, an overlooked method in arthropod studies?

    Science.gov (United States)

    Dujardin, Jean-Pierre; Kaba, D; Solano, P; Dupraz, M; McCoy, K D; Jaramillo-O, N

    2014-12-01

    Modern methods allow a geometric representation of forms, separating size and shape. In entomology, as well as in many other fields involving arthropod studies, shape variation has proved useful for species identification and population characterization. In medical entomology, it has been applied to very specific questions such as population structure, reinfestation of insecticide-treated areas and cryptic species recognition. For shape comparisons, great importance is given to the quality of landmarks in terms of comparability. Two conceptually and statistically separate approaches are: (i) landmark-based morphometrics, based on the relative position of a few anatomical "true" or "traditional" landmarks, and (ii) outline-based morphometrics, which captures the contour of forms through a sequence of close "pseudo-landmarks". Most of the studies on insects of medical, veterinary or economic importance make use of the landmark approach. The present survey makes a case for the outline method, here based on elliptic Fourier analysis. The collection of pseudo-landmarks may require the manual digitization of many points and, for this reason, might appear less attractive. It, however, has the ability to compare homologous organs or structures having no landmarks at all. This strength offers the possibility to study a wider range of anatomical structures and thus, a larger range of arthropods. We present a few examples highlighting its interest for separating close or cryptic species, or characterizing conspecific geographic populations, in a series of different vector organisms. In this simple application, i.e. the recognition of close or cryptic forms, the outline approach provided similar scores as those obtained by the landmark-based approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. MORPHOMETRIC ANALYSIS OF CORPUS CALLOSUM- A STUDY IN CADAVER AND MRI

    Directory of Open Access Journals (Sweden)

    Ambili Puthanveetil

    2017-07-01

    Full Text Available BACKGROUND The Corpus Callosum (CC can best be seen in the mid-sagittal section of brain both in cadaver and MRI. The morphometric measurements of the same will be of use in neurosurgical procedures. Sexual dimorphism and the age-related changes in its measurements remained controversial. Till date, no studies have been done on corpus callosum in Kerala. MATERIALS AND METHODS Measurements of CC has been taken and studied in detail in 24 formalin fixed brains from the Department of Anatomy and 48 MR images from the Department of Radiology. The changes according to age and sex were analysed. RESULTS The mean length of CC in the cadaver was 7.24 cm, which was 3.38 cm posterior to frontal pole and 5.73 cm anterior to occipital pole. In MR images, the mean length was 7.10 in males and 6.76 in females. The difference we got was not statistically significant. The length increased with age. Thickness of genu and body decreased as the age advances, but the splenial thickness was found to be increasing with age. There was significant correlation between the thicknesses of various parts of CC. CONCLUSION The values were almost similar to those in the previous studies. Morphometrically, a significant gender difference was not identified in the present study. There were changes according to age both in males and females.

  14. Establishing some Correlations between Certain Morphometric Parameters and Embryo Quality

    Directory of Open Access Journals (Sweden)

    Nicolae Păcală

    2011-05-01

    Full Text Available The aim of this paper was to establish some correlations between certain morphometric parameters and embryo quality. The morphometric parameters taken into consideration were: zona pellucida thickness, outer and inner diameter, and outer and inner perimeter. For experiments we used embryos recovered at 24 hours from mouse females superovulated with gonadotrope hormones (eCG and hCG. The embryos recovered were cultivated in KSOM media, supplemented with amino acids, and during the in vitro cultivation they were measured at different time intervals for establishing morphometric parameters. The data obtained were statistically analyzed using Minitab 15, using Fitted Line Plot regression that allows testing of the linear and polynomial regression of one variable. After statistical analyze of the data we found that the thickness of the zona pellucida can constitute a morphometric parameter that can be used as an indicator of subsequent development of the 2 cell embryos to morula and blastocyst stage respectively. The other morphometric parameters studied (outer and inner diameter, and outer and inner perimeter cannot be used as indicators of the embryo development.

  15. A computed tomography morphometric study of occipital bone and C2 pedicle anatomy for occipital-cervical fusion.

    Science.gov (United States)

    King, Nicolas K K; Rajendra, Tiruchelvarayan; Ng, Ivan; Ng, Wai Hoe

    2014-01-01

    Occipital-cervical fusion (OCF) has been used to treat instability of the occipito-cervical junction and to provide biomechanical stability after decompressive surgery. The specific areas that require detailed morphologic knowledge to prevent technical failures are the thickness of the occipital bone and diameter of the C2 pedicle, as the occipital midline bone and the C2 pedicle have structurally the strongest bone to provide the biomechanical purchase for cranio-cervical instrumentation. The aim of this study was to perform a quantitative morphometric analysis using computed tomography (CT) to determine the variability of the occipital bone thickness and C2 pedicle thickness to optimize screw placement for OCF in a South East Asian population. Thirty patients undergoing cranio-cervical junction instrumentation during the period 2008-2010 were included. The thickness of the occipital bone and the length and diameter of the C2 pedicle were measured based on CT. The thickest point on the occipital bone was in the midline with a maximum thickness below the external occipital protuberance of 16.2 mm (±3.0 mm), which was thicker than in the Western population. The average C2 pedicle diameter was 5.3 mm (±2.0 mm). This was smaller than Western population pedicle diameters. The average length of the both pedicles to the midpoint of the C2 vertebral body was 23.5 mm (±3.3 mm on the left and ±2.3 mm on the right). The results of this first study in the South East Asian population should help guide and improve the safety in occipito-cervical region instrumentation. Thus reducing the risk of technical failures and neuro-vascular injury.

  16. Correlation of F-18 FDG PET with morphometric tumor response after neoadjuvant chemoradiation in locally advanced (stage III) non-small cell lung cancer (NSCLC)

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Bonnet, R.; Presselt, N.; Przetak, C.; Junker, K.; Schneider, C.P.; Hoeffken, K.; Wendt, T.G.

    2002-01-01

    Aim: To determine the role of 2-[(18)F] fluoro-2- deoxy-D-glucose (FDG) positron emission tomography (PET) in morphometric tumor response after neoadjuvant chemoradiation, findings in 32 patients were analyzed prospectively in an ongoing multicenter trial (LUCAS-MD, Germany). Material and Methods: Inclusion criteria was histologically confirmed NSCLC stage IIIA/IIIB. For staging all patients received a PET scan in addition to a spiral CT and/or MRI before therapy. Neoadjuvant treatment consisted of 2-3 cycles of chemotherapy with paclitaxel (225 mg/m 2 ) and carboplatin (AUC 6), each d1 q22 and a block of chemoradiation (45Gy, 1.5Gy b.i.d., concomitant with paclitaxel (50 mg/m 2 ) and carboplatin (AUC = 2), each d1, d8, d15) followed by surgery. All patients received a second PET after completion of neoadjuvant therapy prior to surgery. Whole-body PET (ECAT Exact 47) studies (attenuation corrected, iteratively reconstructed) were obtained 60 min. after injection of 6 MBq/kg body weight F-18 FDG. For semi-quantitative analysis, the tumor standardized uptake values (SUV), the tumor to background SUV ratio (T/B ratio), the metabolic tumor diameter (MTD) and the metabolic tumor index (MTI = SUV x MTD) were assessed in all primary tumors and in metastatic lymph nodes. Additionally, image fusion of PET with CT data was applied (using a HERMES Computer, Nuclear Diagnostics, Sweden). Results: So far, all patients (7/32) with complete metabolic response in lymph node metastases detected by PET, had no vital tumor cells (morphometric regression grade III). In primary tumors showing complete metabolic response, the regression grade was IIB (less than 10% vital tumor cells) or III. Conclusion: Morphometric tumor response after neoadjuvant therapy correlates strongly with metabolic remission by FDG-PET. PET precedes the tumor response as measured by CT after neoadjuvant treatment and may predict the long term therapeutic outcome in stage III NSCLC

  17. Sperm kinematic, head morphometric and kinetic-morphometric subpopulations in the blue fox (Alopex lagopus

    Directory of Open Access Journals (Sweden)

    Carles Soler

    2017-01-01

    Full Text Available This work provides information on the blue fox ejaculated sperm quality needed for seminal dose calculations. Twenty semen samples, obtained by masturbation, were analyzed for kinematic and morphometric parameters by using CASA-Mot and CASA-Morph system and principal component (PC analysis. For motility, eight kinematic parameters were evaluated, which were reduced to PC1, related to linear variables, and PC2, related to oscillatory movement. The whole population was divided into three independent subpopulations: SP1, fast cells with linear movement; SP2, slow cells and nonoscillatory motility; and SP3, medium speed cells and oscillatory movement. In almost all cases, the subpopulation distribution by animal was significantly different. Head morphology analysis generated four size and four shape parameters, which were reduced to PC1, related to size, and PC2, related to shape of the cells. Three morphometric subpopulations existed: SP1: large oval cells; SP2: medium size elongated cells; and SP3: small and short cells. The subpopulation distribution differed between animals. Combining the kinematic and morphometric datasets produced PC1, related to morphometric parameters, and PC2, related to kinematics, which generated four sperm subpopulations - SP1: high oscillatory motility, large and short heads; SP2: medium velocity with small and short heads; SP3: slow motion small and elongated cells; and SP4: high linear speed and large elongated cells. Subpopulation distribution was different in all animals. The establishment of sperm subpopulations from kinematic, morphometric, and combined variables not only improves the well-defined fox semen characteristics and offers a good conceptual basis for fertility and sperm preservation techniques in this species, but also opens the door to use this approach in other species, included humans.

  18. Population studies of Glossina pallidipes in Ethiopia: emphasis on cuticular hydrocarbons and wing morphometric analysis.

    Science.gov (United States)

    Getahun, M N; Cecchi, G; Seyoum, E

    2014-10-01

    Tsetse flies, like many insects, use pheromones for inter- and intra-specific communication. Several of their pheromones are cuticular hydrocarbons (CHCs) that are perceived by contact at close range. We hypothesized that for a successful implementation of the Sterile Insect Technique (SIT), along with proper identification of target area and target species, the target tsetse populations and the sterile flies must chemically communicate with each other. To study the population structuring of Glossina pallidipes in Ethiopia, CHCs were extracted and analyzed from three tsetse belts. As a comparative approach, wing morphometric analysis was performed. The analysis of the relative abundance of CHCs revealed that populations of G. pallidipes from the Rift Valley tsetse belt showed a distinct clustering compared to populations from the other two belts. The spatial pattern of CHC differences was complemented by the wing morphometric analysis. Our data suggest that CHCs of known biological and ecological role, when combined with wing morphometric data, will provide an alternative means for the study of population structuring of Glossina populations. This could aid the planning of area wide control strategies using SIT, which is dependent on sexual competence. Copyright © 2014 International Atomic Energy Agency 2014. Published by Elsevier B.V. All rights reserved.

  19. Morphometric Evaluation of Preeclamptic Placenta Using Light Microscopic Images

    Directory of Open Access Journals (Sweden)

    Rashmi Mukherjee

    2014-01-01

    Full Text Available Deficient trophoblast invasion and anomalies in placental development generally lead to preeclampsia (PE but the inter-relationship between placental function and morphology in PE still remains unknown. The aim of this study was to evaluate the morphometric features of placental villi and capillaries in preeclamptic and normal placentae. The study included light microscopic images of placental tissue sections of 40 preeclamptic and 35 normotensive pregnant women. Preprocessing and segmentation of these images were performed to characterize the villi and capillaries. Fisher’s linear discriminant analysis (FLDA, hierarchical cluster analysis (HCA, and principal component analysis (PCA were applied to identify the most significant placental (morphometric features from microscopic images. A total of 10 morphometric features were extracted, of which the villous parameters were significantly altered in PE. FLDA identified 5 highly significant morphometric features (>90% overall discrimination accuracy. Two large subclusters were clearly visible in HCA based dendrogram. PCA returned three most significant principal components cumulatively explaining 98.4% of the total variance based on these 5 significant features. Hence, quantitative microscopic evaluation revealed that placental morphometry plays an important role in characterizing PE, where the villous is the major component that is affected.

  20. PRAGMA-CF. A quantitative structural lung disease CT outcome in young children with cystic fibrosis

    DEFF Research Database (Denmark)

    Rosenow, Tim; Oudraad, Merel C.J.; Murray, Conor P.

    2015-01-01

    RATIONALE: Chest computed tomography (CT) is the gold standard for demonstrating cystic fibrosis (CF) airways disease. However, there are no standardised outcome measures appropriate for children under 6 years. OBJECTIVES: We developed the Perth-Rotterdam Annotated Grid Morphometric Analysis for ...

  1. Sex determination from the frontal bone: a geometric morphometric study.

    Science.gov (United States)

    Perlaza, Néstor A

    2014-09-01

    Sex estimation in human skeletal remains when using the cranium through traditional methods is a fundamental pillar in human identification; however, it may be possible to incur in a margin of error due because of the state of preservation in incomplete or fragmented remains. The aim of this investigation was sex estimation through the geometric morphometric analysis of the frontal bone. The sample employed 60 lateral radiographs of adult subjects of both sexes (30 males and 30 females), aged between 18 and 40 years, with mean age for males of 28 ± 4 and 30 ± 6 years for females. Thin-plate splines evidenced strong expansion of the glabellar region in males and contraction in females. No significant differences were found between sexes with respect to size. The findings suggest differences in shape and size in the glabellar region, besides reaffirming the use of geometric morphometrics as a quantitative method in sex estimation. © 2014 American Academy of Forensic Sciences.

  2. CT morphometric analysis to determine the anatomical basis for the use of transpedicular screws during reconstruction and fixations of anterior cervical vertebrae.

    Directory of Open Access Journals (Sweden)

    Chun Chen

    Full Text Available BACKGROUND: Accurate placement of pedicle screw during Anterior Transpedicular Screw fixation (ATPS in cervical spine depends on accurate anatomical knowledge of the vertebrae. However, little is known of the morphometric characteristics of cervical vertebrae in Chinese population. METHODS: Three-dimensional reconstructions of CT images were performed for 80 cases. The anatomic data and screw fixation parameters for ATPS fixation were measured using the Mimics software. FINDINGS: The overall mean OPW, OPH and PAL ranged from 5.81 to 7.49 mm, 7.77 to 8.69 mm, and 33.40 to 31.13 mm separately, and SPA was 93.54 to 109.36 degrees from C3 to C6, 104.99 degrees at C7, whereas, 49.00 to 32.26 degrees from C4 to C7, 46.79 degrees at C3 (TPA. Dl/rSIP had an increasing trend away from upper endplate with mean value from 1.87 to 5.83 mm. Dl/rTIP was located at the lateral portion of the anterior cortex of vertebrae for C3 to C5 and ipsilateral for C6 to C7 with mean value from -2.70 to -3.00 mm, and 0.17 to 3.18 mm. The entrance points for pedicular screw insertion for C3 to C5 and C6 to C7 were recommended -2∼-3 mm and 0-4 mm from the median sagittal plane, respectively, 1-4 mm and 5-6 mm from the upper endplate, with TPA being 46.79-49.00 degrees and 40.89-32.26 degrees, respectively, and SPA being 93.54-106.69 degrees and 109.36-104.99 degrees, respectively. The pedicle screw insertion diameter was recommended 3.5 mm (C3 and C4, 4.0 mm (C5 to C7, and the pedicle axial length was 21-24 mm for C3 to C7 for both genders. However, the ATPS insertion in C3 should be individualized given its relatively small anatomical dimensions. CONCLUSIONS: The data provided a morphometric basis for the ATPS fixation technique in lower cervical fixation. It will help in preoperative planning and execution of this surgery.

  3. 2D/3D Quantification of bone morphometric parameter changes using X-ray microtomograpphy with different pixel sizes

    International Nuclear Information System (INIS)

    Vidal, F.; Assis, J.T. de; Lopes, R.T.; Lima, I.

    2014-01-01

    In recent years, bone quantification led to a deeper knowledge of the 3D microarchitecture. In this study the bone architecture of rats was investigated based on 2D/3D morphometric analysis using microcomputed tomography, aiming at determining the effect of the image acquisition pixel on the quality of some 2D/3D morphometric parameters, such as porosity and trabecular density. Six pairs of bone samples were used and the scans were carried out using high microcomputed tomography system, operating at three different pixel sizes of 33.3 μm, 15.0 μm and 9.5 μm. The results showed 2D parameters values lower than those obtained in the 3D analysis, mainly for trabecular density, separation and thickness. - Highlights: ► Bone quantification led to a deeper knowledge of the 3D microarchitecture. ► μCT was used in order to investigate condyles bone in 03 different pixel sizes. ► The results showed 2D parameters values lower than those obtained in the 3D analysis. ► The parameters trabecular density, separation and thickness were the most affected

  4. Geometric morphometrics as a tool for improving the comparative study of behavioural postures.

    Science.gov (United States)

    Fureix, Carole; Hausberger, Martine; Seneque, Emilie; Morisset, Stéphane; Baylac, Michel; Cornette, Raphaël; Biquand, Véronique; Deleporte, Pierre

    2011-07-01

    Describing postures has always been a central concern when studying behaviour. However, attempts to compare postures objectively at phylogenetical, populational, inter- or intra-individual levels generally either rely upon a few key elements or remain highly subjective. Here, we propose a novel approach, based on well-established geometric morphometrics, to describe and to analyse postures globally (i.e. considering the animal's body posture in its entirety rather than focusing only on a few salient elements, such as head or tail position). Geometric morphometrics is concerned with describing and comparing variation and changes in the form (size and shape) of organisms using the coordinates of a series of homologous landmarks (i.e. positioned in relation to skeletal or muscular cues that are the same for different species for every variety of form and function and that have derived from a common ancestor, i.e. they have a common evolutionary ancestry, e.g. neck, wings, flipper/hand). We applied this approach to horses, using global postures (1) to characterise behaviours that correspond to different arousal levels, (2) to test potential impact of environmental changes on postures. Our application of geometric morphometrics to horse postures showed that this method can be used to characterise behavioural categories, to evaluate the impact of environmental factors (here human actions) and to compare individuals and groups. Beyond its application to horses, this promising approach could be applied to all questions involving the analysis of postures (evolution of displays, expression of emotions, stress and welfare, behavioural repertoires…) and could lead to a whole new line of research.

  5. Postmortem acinar autolysis in rat sublingual gland: a morphometric study.

    Science.gov (United States)

    Nery, Leticia Rodrigues; Moreira, Carla Ruffeil; Cestari, Tania Mary; Taga, Rumio; Damante, José Humberto

    2010-01-01

    To analyze and to quantify morphological acinar postmortem changes in rat sublingual glands (SLG). MATERIAL AND METHODSs: Fifty rats were divided into two groups of 25 animals each. Group I was used for morphological and morphometric evaluations and group II for the determination of gland density and processed gland volume. Acinar autolytic changes were studied at 0 (control group), 3, 6, 12 and 24 h postmortem periods. The morphometric analysis of the volume density (Vv) and total volume (Vt) of intact (ia) and autolyzed (aa) acini was performed under light microscopy using a Zeiss II integration grid with 100 symmetrically distributed points. Morphologically, temporal progressive nuclear alterations and gradual loss of the structural architecture of acinar cells were found. Regarding quantitative results, both the Vvaa and the Vvia showed statistically significant differences among all postmortem periods (p0.05), respectively. Vtaa increased from 0.18 mm³ at 0 h to 38.17 mm³ at 12 h, while Vtia showed a decrease from 33.47 mm³ to 0 mm³ between 3-24 h postmortem. Data concerning Vtaa were adjusted by two-variable linear regression, obtaining the equation: y=-3.54+3.38x (r²=0.90). The Vtaa growth rate calculated by this equation was 3.38 mm³/h between 0-12 h. Acinar autolysis on rat SLG demonstrated the most significant signs during the first 6 h postmortem and was widely spread through the gland at 12 h.

  6. Retrospective Morphometric Analysis of the Infraorbital Foramen ...

    African Journals Online (AJOL)

    Objective: The aim of our study is to examine the morphometric characteristics of the infraorbital foramen (IOF) and its anatomic localization by using conebeam computerized tomography (CBCT). Materials and Methods: In our study, the anatomic characteristics of the IOF were identified by studying retrospectively the CBCT ...

  7. Morphometric Study on Male Specimens of Hyalomma Anatolicum (Acari: Ixodidae in West of Iran

    Directory of Open Access Journals (Sweden)

    M Abdigoudarzi

    2011-12-01

    Full Text Available Background: Hyalomma anatolicum is the well-known hard tick, which is one of the most important livestock and hu­man pathogens vector, wide range in host and distributed in all over the Hyalomma geographic fauna as well as in Iran. Taxonomy of the Hyalomma ssp. is debatable whereas their identification is a problematic work. The reasons for this claim is time consuming Delpy’s researches in Iran also Schulze School, Feldman-Muhsam and the Russian tick workers. We would like to understand morphometric variation in the field collected H. anatolicum in Iran also validat­ing some morphologic quantitative and qualitative characters.Methods: A total 247 field-collected tick specimens from different geographical regions in west of Iran includes Khuzestan and Lorestan Provinces were studied. The morphologic characters of the ticks were measured by the cali­brated stereomicroscope ‎armed scaled lens. The measurements were analyzed using SPSS ‎for windows, version 16 on an IBM PC, ‎so varied shapes of species in different geographic ‎regions were drawn by the ‎aid of a drawing tube con­nected to a light stereomicroscope.‎Results: One way ANOVA test revealed significant differences among the quantitative parameters in five zones (P<‎‎ 0.‎‎00‎‎1‎ also each zone to other zone by Post Hoc Tests e.g. LSD. No significant differences in the lateral grooves length/conscutum length ratio parameter were found.Conclusion: Morphometric variation in Hyalomma spp is poorly studied. The variation in range and quantity of the mor­phometric parameters of H.anatolicum ‎underlies that the correct recognition and key construction for Hyalomma spe­cies dependes ‎on a complement morphometric study on the other species.

  8. Quantification of in-stent restenosis parameters in rabbits by micro-CT

    International Nuclear Information System (INIS)

    Langheinrich, A.C.; Zoerb, C.; Jajima, J.; Lommel, D.; Rau, W.S.; Walker, G.; Mueller, K.M.; Bohle, R.M.

    2005-01-01

    Purpose: The well-defined model of angioplasty and stent implantation in the rabbit aorta is useful in experimental studies of restenosis. This study was performed to evaluate the feasibility of Micro-CT for quantification of in-stent restenosis in a rabbit aortic in-stent restenosis model. Material and Methods: To induce in-stent restenosis seven female New Zealand rabbits underwent balloon dilation and denudation prior to stenting the abdominal aorta. After six weeks on atherogenic diet, animals were killed and the aorta was perfused with contrast agent. Micro-CT morphometric analysis of balloon and stent injured arteries obtained by 700 transverse sections (voxel size 10 μm) was compared to conventional histological analysis. Results: Intimal hyperplasia was present in stented and balloon injured arteries with a moderate intimal area assessed by Micro-CT and conventional histology (3.91±0.5 mm 2 vs. 4.18±0.42; r=0.9). High significant correlations between Micro-CT image analysis and conventional histomorphometry were obtained for lesion size, size of media, size of lumen and stent area (r=0.84 to 0.96). Conclusion: Micro-CT is feasible for quantitative information about restenosis following balloon angioplasty and stent implantation and has the potential to become a standard technique in many laboratories which will augment serial histology as the reference method for ex-vivo studies of restenosis. (orig.)

  9. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT.

    Science.gov (United States)

    Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde

    The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except

  10. Novel Automated Morphometric and Kinematic Handwriting Assessment: A Validity Study in Children with ASD and ADHD

    Science.gov (United States)

    Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.

    2017-01-01

    This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…

  11. Magnetic resonance imaging in schizophrenia: a morphometric study

    International Nuclear Information System (INIS)

    Castro, Claudio Campi de

    2001-01-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  12. Histopathological and Digital Morphometrical Evaluation of Uterine Leiomyoma in Brazilian Women

    Directory of Open Access Journals (Sweden)

    Ana Paula Fernandes da Silva

    2016-01-01

    Full Text Available The current study aims to evaluate histopathological and digital morphometrical aspects associated with uterine leiomyomas in one hundred and fifty (150 patients diagnosed with leiomyoma. Uterine tissues were subjected to the histopathological and digital morphometric analyses of the interstitial collagen distribution. The analysis of medical records indicates that most of the women diagnosed with uterine leiomyomas (68.7% are between 37 and 48 years old. As for the anatomic location of the tumors, approximately 61.4% of the patients had intramural and subserosal lesions. In 50% of the studied cases, the patients developed uterine leiomyomatosis (with more than eight tumors. As for the morphometric study, the average size of the interstitial collagen distribution held approximately 28.53% of the capture area, whereas it was of 7.43% in the normal tissue adjacent to the tumor. Another important aspect observed in the current study was the high rate of young women subjected to total hysterectomy, a fact that resulted in early and definitive sterility.

  13. A Morphometric Study of Auricular Concha in the Population of Young Chinese Adults

    OpenAIRE

    Zhu, Zhaohua; Ji, Xiaomin; Gao, Zhu; Hu, Gang

    2017-01-01

    SUMMARY: A detailed data of concha is currently not available. Therefore, the present study aimed to determine twelve morphometric measurements of concha, to investigate its sexual dimorphism and bilateral asymmetry, and to establish basic shapes of concha for both sexes and sides. The study sample comprised of 310 young Chinese aged 18-28 years. 141 left and 141 right ear impressions for females, 169 left and 169 right ear impressions for males were collected and scanned. The 3D coordinates ...

  14. Quantification of Runoff as Influenced by Morphometric Characteristics in a Rural Complex Catchment

    Science.gov (United States)

    Abdulkareem, Jabir Haruna; Pradhan, Biswajeet; Sulaiman, Wan Nor Azmin; Jamil, Nor Rohaizah

    2018-03-01

    This study addresses the critical scientific question of assessing the relationship between morphometric features and the hydrological factors that increase the risk of flooding in Kelantan River basin, Malaysia. Two hypotheses were developed to achieve this aim, namely: the alternate hypothesis (runoff, is influenced by morphometric characteristics in the study watershed) and the null hypothesis (runoff is not influenced by morphometric characteristics). First, the watershed was delineated into four major catchments, namely: Galas, Pergau, Lebir, and Nenggiri. Next, quantitative morphometric characters such as linear aspects, areal aspects, and relief aspects were determined on each of these catchments. Furthermore, HEC-HMS and flood response analyses were employed to simulate the hydrological response of the catchments. From the results of morphometric analysis, profound spatial changes were observed between runoff features of Kelantan River and the morphometric characteristics. The length of overflow that was related to drainage density and constant channel maintenance was found to be 0.12 in Pergau, 0.04 in both Nenggiri and Lebir, and 0.03 in Galas. Drainage density as influenced by geology and vegetation density was found to be low in all the catchments (0.07-0.24). Results of hydrological response indicated that Lebir, Nenggiri, Galas, and Pergau recorded a flood response factor of 0.75, 0.63, 0.40, and 0.05, respectively. Therefore, Lebir and Nenggiri are more likely to be flooded during a rainstorm. There was no clear indication with regard to the catchment that emerged as the most prevailing in all the morphological features. Hence, the alternate hypothesis was affirmed. This study can be replicated in other catchments with different hydrologic setup.

  15. Morphometric evaluation of Arbor Acre parent stock broilers reared ...

    African Journals Online (AJOL)

    Morphometric evaluation of Arbor Acre parent stock broilers reared in ... Economic importance of morphometric parameters such as live weight and body ... (R2) value of 60.30 included forecast indices such as BL, WS, WL, TL, BG and SL.

  16. Immunohistochemical and morphometric study of the development of fetal and newborn rat pancreatic islets

    International Nuclear Information System (INIS)

    Badawoud, Mohammed H.

    2003-01-01

    Aim of this study is to perform a detailed morphometric immunohistochemichal study of develpment of fetal and newborn rat pancreatic islets. 24 pancreas were obtained from 19 and 21-day-old fetal rats,1 and 4-day-old newborn rats. They were fixed in a buffered neutral formalin ,dehydrated and embedded in paraplast. Sections were stained with anti-insulin antibodies. Study was performed at Department of Anatomy, King Abdul-Aziz University, Jeddah,Kingdom of Saudi Arabia, between 2001 and 2002. The volume density of B cells showed a grdual increase during the last days of gestation and a slight increase during the first 4 days after birth. All the other morphometric parameters showed a gradual increase during the last days of gestation and during the first days after birth.The B cell nuclear diameter and volume showed a slight increase after birth. B cells were stained and present in the central part of of fetal and new born islets,while the other islet cells were present in the periphery of the islets. The size of endocrine tissue, which was represented by the islet diameter, islet volume, islet volume density, total number of islet cells,number of B cells and volume density of B cells showed a progressive increase during the prenatal period. (author)

  17. Morphometric analysis of the mandible in the Durban Metropolitan population of South Africa.

    Science.gov (United States)

    Ishwarkumar, S; Pillay, P; Haffajee, M R; Satyapal, K S

    2017-01-01

    The identification of an individual from skeletal remains plays a vital role in forensic investigation as it is essential for the identification of the individual's age, sex, and/or race and further analysis. Skeletal characteristics differ from one population group to another since population-specific osteometric standards exist for sex determination. Since the mandible is the largest, strongest and most durable compact facial bone, it is the best preserved after death. While sexual dimorphism of the mandible is indicated by its shape and size, morphometric analysis is more accurate in the determination of sex from the skull. The aim of this study was to evaluate the morphometric parameters of the mandible in the Durban Metropolitan population. Various morphometric parameters of the mandible were measured and assessed in 265 digital panoramic radiographs aged between 16 and 30 years (n = 530). Each parameter recorded was statistically analysed using SPSS to determine if a relationship existed between the parameter, and sex and age. In this study the morphometric parameters of the male mandibles were greater than that of the females. This concurred with the findings of previous studies. The length of the mandibular ramus on the right and left sides was statistically significant with sex. This correlated with previous studies, indicating that the length of the mandibular ramus generally has higher sexual dimorphism than any other morphometric mandibular parameter (p = 0.000). However, only the length of the right mandibular body was statistically significant when compared with sex (p = 0.040). The findings of this study may assist forensic investigators, anatomists, anthropologists and maxillo-facial surgeons.

  18. A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry.

    Science.gov (United States)

    Damstra, Janalt; Fourie, Zacharias; De Wit, Marnix; Ren, Yijin

    2012-02-01

    Morphometric methods are used in biology to study object symmetry in living organisms and to determine the true plane of symmetry. The aim of this study was to determine if there are clinical differences between three-dimensional (3D) cephalometric midsagittal planes used to describe craniofacial asymmetry and a true symmetry plane derived from a morphometric method based on visible facial features. The sample consisted of 14 dry skulls (9 symmetric and 5 asymmetric) with metallic markers which were imaged with cone-beam computed tomography. An error study and statistical analysis were performed to validate the morphometric method. The morphometric and conventional cephalometric planes were constructed and compared. The 3D cephalometric planes constructed as perpendiculars to the Frankfort horizontal plane resembled the morphometric plane the most in both the symmetric and asymmetric groups with mean differences of less than 1.00 mm for most variables. However, the standard deviations were often large and clinically significant for these variables. There were clinically relevant differences (>1.00 mm) between the different 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features. The difference between 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features were clinically relevant. Care has to be taken using cephalometric midsagittal planes for diagnosis and treatment planning of craniofacial asymmetry as they might differ from the true plane of symmetry as determined by morphometrics.

  19. Morphometric synaptology of a whole neuron profile using a semiautomatic interactive computer system.

    Science.gov (United States)

    Saito, K; Niki, K

    1983-07-01

    We propose a new method of dealing with morphometric synaptology that processes all synapses and boutons around the HRP marked neuron on a large composite electron micrograph, rather than a qualitative or a piecemeal quantitative study of a particular synapse and/or bouton that is not positioned on the surface of the neuron. This approach requires the development of both neuroanatomical procedures, by which a specific whole neuronal profile is identified, and valuable specialized tools, which support the collection and analysis of a great volume of morphometric data from composite electron micrographs, in order to reduce the burden of the morphologist. The present report is also concerned with the total and reliable semi-automatic interactive computer system for gathering and analyzing morphometric data that has been under development in our laboratory. A morphologist performs the pattern recognition portion by using a large-sized tablet digitizer and a menu-sheet command, and the system registers the various morphometric values of many different neurons and performs statistical analysis. Some examples of morphometric measurements and analysis show the usefulness and efficiency of the proposed system and method.

  20. ROUNDSCALE SPEARFISH branchiostegal morphometric data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The morphometric characteristics that separate white marlin Kajikia albidus from roundscale spearfish Tetrapturus georgii can be difficult for non-experts to...

  1. A geometric morphometric study into the sexual dimorphism of the human scapula.

    Science.gov (United States)

    Scholtz, Y; Steyn, M; Pretorius, E

    2010-08-01

    Sex determination is vital when attempting to establish identity from skeletal remains. Two approaches to sex determination exists: morphological and metrical. The aim of this paper was to use geometric morphometrics to study the shape of the scapula and its sexual dimorphism. The sample comprised 45 adult black male and 45 adult black female scapulae of known sex. The scapulae were photographed and 21 homologous landmarks were plotted to use for geometric morphometric analysis with the 'tps' series of programs, as well as the IMP package. Consensus thin-plate splines and vector plots for males and females were compared. The CVA and TwoGroup analyses indicated that significant differences exist between males and females. The lateral and medial borders of females are straighter while the supraspinous fossa is more convexly curved than that of males. More than 91% of the females and 95% of the males were correctly assigned. Hotelling's T(2)-test yielded a significant p-value of 0.00039. In addition, 100 equidistant landmarks representing the curve only were also assigned. These, however, yielded considerably poorer results. It is concluded that it is better to use homologous landmarks rather than curve data only, as it is most probable that the shape of the outline relative to the fixed homologous points on the scapula is sexually dimorphic.

  2. Effects of freezing on white perch Morone americana (Gmelin, 1789): Implications for multivariate morphometrics

    Science.gov (United States)

    Kocovsky, Patrick

    2016-01-01

    This study tested the hypothesis that duration of freezing differentially affects whole-body morphometrics of a derived teleost. Whole-body morphometrics are frequently analyzed to test hypotheses of different species, or stocks within a species, of fishes. Specimens used for morphometric analyses are typically fixed or preserved prior to analysis, yet little research has been done on how fixation or preservation methods or duration of preservation of specimens might affect outcomes of multivariate statistical analyses of differences in shape. To determine whether whole-body morphometrics changed as a result of freezing, 23 whole-body morphometrics of age-1 white perch (Morone americana) from western Lake Erie (n = 211) were analyzed immediately after capture, after being held on ice overnight, and after freezing for 100 or 200 days. Discriminant function analysis revealed that all four groups differed significantly from one another (P time to avoid biases related to the length of time they were frozen. Similar experiments should be conducted on other species and also using formalin- and alcohol-preserved specimens.

  3. Vitamin B12 deficiency: Characterization of psychometrics and MRI morphometrics.

    Science.gov (United States)

    Hsu, Yen-Hsuan; Huang, Ching-Feng; Lo, Chung-Ping; Wang, Tzu-Lan; Tu, Min-Chien

    2016-01-01

    Vitamin B12 is essential for the integrity of the central nervous system. However, performances in different cognitive domains relevant to vitamin B12 deficiency remain to be detailed. To date, there have been limited studies that examined the relationships between cognitions and structural neuroimaging in a single cohort of low-vitamin B12 status. The present study aimed to depict psychometrics and magnetic resonance imaging (MRI) morphometrics among patients with vitamin B12 deficiency, and to examine their inter-relations. We compared 34 consecutive patients with vitamin B12 deficiency (serum level ≤ 250 pg/ml) to 34 demographically matched controls by their cognitive performances and morphometric indices of brain MRI. The correlations between psychometrics and morphometrics were analyzed. The vitamin B12 deficiency group had lower scores than the controls on total scores of Mini-Mental Status Examination (MMSE) and Cognitive Abilities Screening Instrument (CASI) (both P psychometric and morphometric indices, pronounced correlations between bicaudate ratio and long-term memory, mental manipulation, orientation, language, and verbal fluency were noted (all P < 0.01). Vitamin B12 deficiency is associated with a global cognition decline with language, orientation, and mental manipulation selectively impaired. Preferential atrophy in frontal regions is the main neuroimaging feature. Although the frontal ratio highlights the relevant atrophy among patients, the bicaudate ratio might be the best index on the basis of its strong association with global cognition and related cognitive domains, implying dysfunction of fronto-subcortical circuits as the fundamental pathogenesis related to vitamin B12 deficiency.

  4. Semi-automated landmark-based 3D analysis reveals new morphometric characteristics in the trochlear dysplastic femur.

    Science.gov (United States)

    Van Haver, Annemieke; De Roo, Karel; De Beule, Matthieu; Van Cauter, Sofie; Audenaert, Emmanuel; Claessens, Tom; Verdonk, Peter

    2014-11-01

    The authors hypothesise that the trochlear dysplastic distal femur is not only characterised by morphological changes to the trochlea. The purpose of this study is to describe the morphological characteristics of the trochlear dysplastic femur in and outside the trochlear region with a landmark-based 3D analysis. Arthro-CT scans of 20 trochlear dysplastic and 20 normal knees were used to generate 3D models including the cartilage. To rule out size differences, a set of landmarks were defined on the distal femur to isotropically scale the 3D models to a standard size. A predefined series of landmark-based reference planes were applied on the distal femur. With these landmarks and reference planes, a series of previously described characteristics associated with trochlear dysplasia as well as a series of morphometric characteristics were measured. For the previously described characteristics, the analysis replicated highly significant differences between trochlear dysplastic and normal knees. Furthermore, the analysis showed that, when knee size is taken into account, the cut-off values of the trochlear bump and depth would be 1 mm larger in the largest knees compared to the smallest knees. For the morphometric characteristics, the analysis revealed that the trochlear dysplastic femur is also characterised by a 10% smaller intercondylar notch, 6-8% larger posterior condyles (lateral-medial) in the anteroposterior direction and a 6% larger medial condyle in the proximodistal direction compared to a normal femur. This study shows that knee size is important in the application of absolute metric cut-off values and that the posterior femur also shows a significantly different morphology.

  5. Morphometric studies on the facial skeleton of humans and pongids based on CT-scans.

    Science.gov (United States)

    Schumacher, K U; Koppe, T; Fanghänel, J; Schumacher, G H; Nagai, H

    1994-10-01

    The changes of the skull, which we can observe during the anthropogenesis, are reflected especially in the different skull proportions. We carried out metric measurements at the median level on 10 adult skulls each of humans, chimpanzees and gorillas as well as 11 skulls of orangutans. All skulls were scanned with a CT at the median level. We measured the lines and angles of the scans and the means and the standard deviations were calculated. We carried out a correlation analysis to observe the relation of their characteristics. We showed that there is a relation between the length of the skull base and the facial length in all species. From the results of the correlation analysis, we can also conclude that a relation exists between the degree of prognathism and the different length measurements of the facial skeleton. We also found a bending of the facial skeleton in relation to the cranial base towards the ventral side, also known as klinorhynchy, in all observed species. The highest degree of klinorhynchy was found in humans and the lowest in orangutans. We will discuss the different definition of the term klinorhynchy and its importance in the evolution of the hominoids.

  6. Morphometric analysis in basaltic Terrain of Central India using GIS techniques: a case study

    Science.gov (United States)

    Sahu, Nisha; Obi Reddy, G. P.; Kumar, Nirmal; Nagaraju, M. S. S.; Srivastava, Rajeev; Singh, S. K.

    2017-09-01

    Morphometric analysis is significant for investigation and management of the watershed. This study depicts the morphometric analysis of Miniwada Watershed in Nagpur district, Maharashtra, Central India using Geographic Information System (GIS) techniques, which has been carried out through measurement of various aspects like linear, aerial and relief aspects of watershed. The drainage network of the watershed was generated from Cartosat-I DEM (10 m) using ESRI Software ArcGIS (ver.10.2). The analysis reveals that drainage pattern is dendritic and the stream order in the watershed varies from 1 to 4. The total number of stream segments of all orders counted as 37, out of which the majority of orders (70.27 %) was covered by 1st order streams and 4th order stream segments covers only 2.70 %. The bifurcation ratio reflects the geological and tectonic characteristics of the watershed and estimated as 3.08. The drainage density of the watershed is 3.63 km/sq km and it indicates the closeness of spacing of channels. The systematic analysis of various parameters in GIS helps in better understanding the soil resources distribution, watersheds prioritization, planning and management.

  7. Construction of Individual Morphological Brain Networks with Multiple Morphometric Features

    Directory of Open Access Journals (Sweden)

    Chunlan Yang

    2017-04-01

    Full Text Available In recent years, researchers have increased attentions to the morphological brain network, which is generally constructed by measuring the mathematical correlation across regions using a certain morphometric feature, such as regional cortical thickness and voxel intensity. However, cerebral structure can be characterized by various factors, such as regional volume, surface area, and curvature. Moreover, most of the morphological brain networks are population-based, which has limitations in the investigations of individual difference and clinical applications. Hence, we have extended previous studies by proposing a novel method for realizing the construction of an individual-based morphological brain network through a combination of multiple morphometric features. In particular, interregional connections are estimated using our newly introduced feature vectors, namely, the Pearson correlation coefficient of the concatenation of seven morphometric features. Experiments were performed on a healthy cohort of 55 subjects (24 males aged from 20 to 29 and 31 females aged from 20 to 28 each scanned twice, and reproducibility was evaluated through test–retest reliability. The robustness of morphometric features was measured firstly to select the more reproducible features to form the connectomes. Then the topological properties were analyzed and compared with previous reports of different modalities. Small-worldness was observed in all the subjects at the range of the entire network sparsity (20–40%, and configurations were comparable with previous findings at the sparsity of 23%. The spatial distributions of the hub were found to be significantly influenced by the individual variances, and the hubs obtained by averaging across subjects and sparsities showed correspondence with previous reports. The intraclass coefficient of graphic properties (clustering coefficient = 0.83, characteristic path length = 0.81, betweenness centrality = 0.78 indicates

  8. Micro-computed tomography (μCT) as a novel method in ecotoxicology - determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    NARCIS (Netherlands)

    Brinkmann, M.; Rizzo, L.Y.; Lammers, Twan Gerardus Gertudis Maria; Gremse, F.; Schiwy, S.; Kiessling, F.; Hollert, H.

    2016-01-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's

  9. Longitudinal morphometric MRI study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Ogomori, Koji; Takano, Koichi; Kuwabara, Yasuo; Nakano, Seigo; Nawata, Hideyuki; Yano, Rika; Nishimura, Ryoji; Takita, Masashi

    2009-01-01

    A longitudinal morphometric MRI study of Alzheimer's disease (AD) was conducted to determine the relationship between the progression of the symptoms and the progression of the brain atrophy. The Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), developed by Matsuda et al. was used as a method of morphometry to perform the statistical MR image analysis. Thirty-eight patients of AD patients were investigated with VSRAD. These patients were divided into two groups according to the progression of symptoms based on a clinical evaluation. One group was the progress group (20 patients), while the other group was the stable group (18 patients) for comparison. The relationship was investigated between the speed of the symptomatic progression and the change in each VSRAD indicator. Consequently, the entorhinal Z-score and the entorhinal atrophy rate showed a correlation with the speed of the symptomatic progression. The increase of the entorhinal Z-score in the follow-up was larger in the progress group than that in the stable group (0.65/1.28 years in the progress group and 0.05/1.26 years in the stable group.). These results suggest that a rapid symptomatic progression in an AD patient accompanies the rapid progression of atrophy in the entorhinal cortex. (author)

  10. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  11. Interrelationships between morphometric variables and rounded fish body yields evaluated by path analysis

    Directory of Open Access Journals (Sweden)

    Rafael Vilhena Reis Neto

    2012-07-01

    Full Text Available The objective of this study was to verify which morphometric measures and ratios are more directly associated with the weight and body yields of rounded fish. A total of 225 specimens of rounded fish (59 pacus, 61 tambaquis, 52 tambacus and 53 paquis with average weight of 972.43 g (±115.52 g were sampled, stunned, slaughtered, weighed, measured, and processed for morphometric and processing yield analysis. The morphometric measures taken were: standard length (CP; head length (CC; head height (AC; body height (A1; and body width (L1. For completeness, the following morphometric ratios were calculated: CC/CP, AC/CP, A1/CP, L1/CP, CC/A1, AC/A1, L1/A1, CC/AC and L1/CC. The yields of carcass, filet, rib and filet with rib were estimated after processing. Initially, a "stepwise" procedure was performed in order to eliminate multicollinearity problems among the morphometric variables, and the phenotypic correlations were then calculated for the dependent variables (weight and body yields and independent variables (morphometric measurements and ratios. These correlations were later deployed in direct and indirect effects through path analysis, and the direct and indirect contributions of each variable were measured in percentage terms. The CC and A1 measures were important for determining the weight of rounded fish. The CC/A1 ratio was the variable most directly associated with carcass yield. For filet, filet with rib and rib yields, the L1/CC ratio was found to be more appropriate and can be used directly.

  12. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  13. Use of morphometric analysis and self-organizing maps for alluvial fan classification: case study on Ostorankooh altitudes, Iran

    International Nuclear Information System (INIS)

    Mokarram, Marzieh; Seif, Abdollah; Sathyamoorthy, Dinesh

    2014-01-01

    The aim of this study is to classify alluvial fans formed by high-gradient braided streams and torrents that discharge into the Oshtorankook altitudes in the Lorestan province, Iran. The morphology of the fans and their watershed is quantitatively described through estimated morphometric parameters. For relationships between geomorphological features of the fans and their drainage basins, self-organizingmaps (SOM) were used. In SOM, according to both qualitative data and morphometric variables, the clustering tendency of alluvial fans was investigated using 15 alluvial fans parameters. The results of the analysis showed that several morphologically different fan types were recognizedbased on their geomorphological characteristics in the study area. A strong positive relationship was found between the drainage basin area and size of the fan with a simple power function. In addition, the relationship between fan slope and drainage area was found to be negative and moderately strong with a simple power function

  14. Parasites and Morphometric Indices of Frozen Fish Sold in Nsukka ...

    African Journals Online (AJOL)

    The parasites and morphometric indices of frozen fish sold in Nsukka Urban Market in Nsukka Local Government Area of Enugu State, Nigeria were investigated between June and December 2008 to determine the parasite prevalence, mean intensity and abundance and some morphometric indices associated with ...

  15. Morphometric features of a low-elevation urban catchment and the ...

    African Journals Online (AJOL)

    River basin morphometric is a geomorphological tool that applies to physical measurements about a river form, from which can be derived quantities that explain its characteristics, such as size, shape, stream network and discharge. This paper used basin morphometric to assess flood occurrence in Port Harcourt, Nigeria.

  16. Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT

    Science.gov (United States)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan

    2017-09-01

    Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and

  17. Morphometric analysis of the Marmara Sea river basins, Turkey

    Science.gov (United States)

    Elbaşı, Emre; Ozdemir, Hasan

    2014-05-01

    The drainage basin, the fundamental unit of the fluvial landscape, has been focus of research aimed at understanding the geometric characteristics of the master channel and its tributary network. This geometry is referred to as the basin morphometry and is nicely reviewed by Abrahams (1984). A great amount of research has focused on geometric characteristic of drainage basins, including the topology of the stream networks, and quantitative description of drainage texture, pattern, shape, and relief characteristics. Evaluation of morphometric parameters necessitates the analysis of various drainage parameters such as ordering of the various streams, measurement of basin area and perimeter, length of drainage channels, drainage density (Dd), stream frequency (Fs), bifurcation ratio (Rb), texture ratio (T), basin relief (Bh), Ruggedness number (Rn), time of concentration (Tc), hypsometric curve and integral (Hc and Hi) (Horton, 1932, Schumn, 1956, Strahler, 1957; Verstappen 1983; Keller and Pinter, 2002; Ozdemir and Bird, 2009). These morphometric parameters have generally been used to predict flood peaks, to assess sediment yield, and to estimate erosion rates in the basins. River basins of the Marmara Sea, has an area of approximately 40,000 sqkm, are the most important basins in Turkey based on their dense populations, industry and transportation systems. The primary aim of this study is to determine and analyse of morphometric characteristics of the Marmara Sea river basins using 10 m resolution Digital Elevation Model (DEM) and to evaluate of the results. For these purposes, digital 10 m contour maps scaled 1:25000 and geological maps scaled 1:100000 were used as the main data sources in the study. 10 m resolution DEM data were created using the contour maps and then drainage networks and their watersheds were extracted using D8 pour point model. Finally, linear, areal and relief morphometries were applied to the river basins using Geographic Information Systems

  18. Morphometric analysis of Dactylorhiza hatagirea (D. Don), a critically ...

    African Journals Online (AJOL)

    The morphometric study was conducted during 2009 to 2010. About 28 morphological characters were measured under 13 natural populations of Dactylorhiza hatagirea. Geographic variation in morphology reflects phenotypic responses to environmental gradients and evolutionary history of populations and species.

  19. Morphometric and landuse analysis: implications on flood hazards ...

    African Journals Online (AJOL)

    This study assessed the morphometric, landuse and lithological attributes of five basins (Iwaraja, Ilesa, Olupona, Osogbo I and Osogbo II) with particular reference to flood hazards in Ilesa and Osogbo metropolis, Osun State Nigeria. Ilesa town is situated within Iwaraja and Ilesa basins while Osogbo metropolis spread ...

  20. Physical and morphometric characterization of indigenous cattle of Assam

    Directory of Open Access Journals (Sweden)

    A. Haque

    2011-01-01

    Full Text Available The present investigation was undertaken to study the physical and morphometric characteristics in indigenous cattle of Assam. The data pertain to 339 indigenous cattle of different categories. The physical characteristics included colour pattern of body coat, muzzle, tail switch, hoof and horn. Body length, height at wither, heart girth, pouch girth, length of tail, switch, neck, ear and head were taken up for morphometric characterization. The main body coat colour of indigenous cattle was brown (31.18% followed by white (28.53%, fawn (15.29%, grey (13.53%, black (4.41% and mixed (7.06%. The prominent colour of tail switch was black (74.53%. Most of animals had black muzzle (86.47%, black hooves (84.71% and black horn (100%. Morphometric characteristics data obtained were classified according to location, age group and sex of the animal. The means for body length, height at wither, heart girth, pouch girth, length of tail, switch, neck, ear and head were 83.668±0.590, 91.942±0.55, 113.146±0.738, 121.181±0.761, 54.196±0.527, 26.098±0.186, 32.705±0.166, 18.131±0.111 and 35.035±0.195 cm respectively. Age and sex had significant effect on all the morphometric characters however, location effect was non significant. The indigenous cattle of Assam are comparatively smaller in size than most of the recognized breeds of cattle however coat colour showed sizeable variation. The data generated for indigenous cattle of Assam would be useful to characterize them.

  1. MORPHOMETRIC CHARACTERISTICS OF RED BLOOD CELLS OF Telestes metohiensis (Steindachner, 1901

    Directory of Open Access Journals (Sweden)

    Radoslav Dekić

    2013-02-01

    Full Text Available The paper presents the morphometric characteristics of red blood cells of endemic fish species of Bosnia and Herzegovina, Telestes metohiensis (Steindachner, 1901 inhabiting the Vrijeka river in the Dabar field. A total of 30 fish were sampled during August, 2010. Morphological measurements included the following parameters: axes of the red blood cells and nuclei, the surface of the red blood cells and nuclei and the thickness of the red blood cells. Morphometric characteristics of the erythrocyte maturation stages (acidophilic and polychromatic erythroblasts were also studied as well as their proportion in the peripheral blood. 100 mature forms were measured for each individual. The propotion of the immature forms was expressed per 1000 erythrocytes. Results showed that dimensions of the erythrocytes differed in systematic categories as well as fish types. Dimensions of mature erythrocytes and their maturation stages of the same species differed in shape and size of the nuclei. Proportion of the erythrocyte maturation stages was very low in comparison with the mature erythrocytes, indicating the optimal environmental conditions for the studied species.Key words: morphometric characteristics, erythrocytes, Telestes metohiensis, proportion of immature stages

  2. Pulmonary hypertension in patients with chronic pulmonary thromboembolism: chest radiograph and CT evaluation before and after surgery

    International Nuclear Information System (INIS)

    Schmidt, H.C.; Kauczor, H.U.; Schild, H.H.; Renner, C.; Kirchhoff, E.; Lang, P.; Iversen, S.; Thelen, M.

    1996-01-01

    The purpose of this study was to assess the value of morphometric data on conventional radiography and CT predicting the presence and degree of pulmonary hypertension and to assess the reversibility after surgery. On preoperative X-ray films and CT scans of 50 patients with pulmonary hypertension secondary to chronic thromboembolism, we measured the cardiothoracic ratio, basal diameter, length of cardiac contact to sternum, pulmonary trunk, right and left descending pulmonary artery, and the septum angle. These data were correlated with pulmonary arterial pressure. In 14 X-ray patients and 18 CT patients, with follow-up after surgical thromboendarterectomy the reversibility of these changes was assessed. A dilated pulmonary trunk was the most common abnormality (96% each on X-ray and CT). Pulmonary arteries were dilated on X-ray in 40% (right) and 14% (left), and on CT in 92% (right) and 96% (left). The best correlation with mean arterial pressure was found measuring the pulmonary trunk on CT (r=0.43, p<0.01). After surgery, reversibility was most significant for the pulmonary trunk on CT (p<0.0001). In patients with chronic pulmonary embolism, pulmonary hypertension can best be predicted by assessing the diameter of the pulmonary trunk both on X-ray and CT. No close correlation is present between the extent of any parameter and the level of the pulmonary pressure. (orig.)

  3. Morphometrical Analysis and Peak Runoff Estimation for the Sub-Lower Niger River Basin, Nigeria

    Directory of Open Access Journals (Sweden)

    Salami Adebayo Wahab

    2016-03-01

    Full Text Available This study utilized Spatial Information Technology (SIT such as Remote Sensing (RS, a Geographical Information System (GIS, the Global Positioning System (GPS and a high-resolution Digital Elevation Model (DEM for a morphometrical analysis of five sub-basins within the Lower Niger River Basin, Nigeria. Morpho-metrical parameters, such as the total relief, relative relief, relief ratio, ruggedness number, texture ratio, elongation ratio, circularity ratio, form factor ratio, drainage density, stream frequency, sinuosity factor and bifurcation ratio, have been computed and analyzed. The study revealed that the contribution of the morphometric parameters to flooding suggest catchment No. 1 has the least concentration time and the highest runoff depth. Catchment No. 4 has the highest circularity ratio (0.35 as the most hazardous site where floods could reach a great volume over a small area.

  4. Morphometric study of newly emerged unmated queens of honey bee Apis mellifera L. in Ismailia Governorate, Egypt

    Directory of Open Access Journals (Sweden)

    S.M. Kamel

    2013-06-01

    Full Text Available Recently, morphometric analysis is being a very good tool for identification of honey bee races and characterization of genetic materials. This fact has motivated the present work to investigate the effects of two grafting methods, three types of artificial queen wax cups and four periods of queen rearing on some morphological characters of newly emerged queens. The developed technique used in the present study depends on the integration between Scanner unit and Photoshop program, called Scan Photo Method (SPM. The measurements of 23 morphological characteristics of reared queens were estimated by using SPM. Results indicated significant differences between periods in the measurements of the studied characteristics on forewing such as cubital index, distance C, distance D, radial field, inner wing length, inner wing width, dumb bell index, distance I, II, III and IV, except cubital A and cubital B. Regarding the effects of cup types and grafting methods, data also revealed significant differences in all measurements of studied characteristics, except tibial length, hind wing length, cubital B, radial field and distance IV. Further works in this area were recommended to find out a relation between some morphometric characters and important of some quantitative characters.

  5. Symmetry analysis of talus bone: A Geometric morphometric approach.

    Science.gov (United States)

    Islam, K; Dobbe, A; Komeili, A; Duke, K; El-Rich, M; Dhillon, S; Adeeb, S; Jomha, N M

    2014-01-01

    The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones. Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified. Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery. We conclude that left and right talus bones of intact human ankle joints show a strong degree of symmetry. The results of this study may have significance with respect to talus surgery, and in investigating traumatic talus injury where the geometric shape of the contralateral talus can be used as control. Cite this article: Bone Joint Res 2014;3:139-45.

  6. Discriminant analysis of morphometric differentiation in the West ...

    African Journals Online (AJOL)

    This study evaluated the usefulness of morphological characteristics to distinguish two important indigenous goat breeds in Nigeria. Fifteen morphometric traits were measured on West African Dwarf – WAD (n = 160) and Red Sokoto – RS (n = 142) goats that ranged in age of up to 19 months and were reared extensively in ...

  7. Morphometric and landsliding analyses in chain domain: the Roccella basin, NE Sicily, Italy

    Science.gov (United States)

    Rapisarda, Francesco

    2009-10-01

    The dynamic interaction of endogenic and exogenic processes in active geodynamic context leads to the deterioration of the physico-mechanical characteristics of the rocks, inducing slopes instability. In such context, the morphometric parameters and the analysis of landslide distribution contribute to appraise the evolutive state of hydrographic basins. The aim of the study is the morphometric characterization of the Roccella Torrent basin (Rtb) located in South Italy. Landsliding and tectonic structure dynamically interact with the drainage pattern that records these effects and permits the definition of the evolutive geomorphic stage of the basin. The Air Photograph Investigation and field surveys permitted to draw the main geomorphic features, the drainage pattern of the Rtb, to calculate the morphometric parameters and to delimit the landslides’ bodies. Detailed analysis about the landslide distribution within a test site 17 km2 wide were carried out to elaborate indicative indexes of the landslides type and to single out the lithotypes that are more involved in slope instability phenomena. The morphometric parameters indicate the rejuvenation state within the Rtb where the stream reaches show the effects of increased energy relief in agreement with the geological settings of this sector of the Apennine-Maghrebian Chain.

  8. Morphometric Identification of Queens, Workers and Intermediates in In Vitro Reared Honey Bees (Apis mellifera).

    Science.gov (United States)

    De Souza, Daiana A; Wang, Ying; Kaftanoglu, Osman; De Jong, David; Amdam, Gro V; Gonçalves, Lionel S; Francoy, Tiago M

    2015-01-01

    In vitro rearing is an important and useful tool for honey bee (Apis mellifera L.) studies. However, it often results in intercastes between queens and workers, which are normally are not seen in hive-reared bees, except when larvae older than three days are grafted for queen rearing. Morphological classification (queen versus worker or intercastes) of bees produced by this method can be subjective and generally depends on size differences. Here, we propose an alternative method for caste classification of female honey bees reared in vitro, based on weight at emergence, ovariole number, spermatheca size and size and shape, and features of the head, mandible and basitarsus. Morphological measurements were made with both traditional morphometric and geometric morphometrics techniques. The classifications were performed by principal component analysis, using naturally developed queens and workers as controls. First, the analysis included all the characters. Subsequently, a new analysis was made without the information about ovariole number and spermatheca size. Geometric morphometrics was less dependent on ovariole number and spermatheca information for caste and intercaste identification. This is useful, since acquiring information concerning these reproductive structures requires time-consuming dissection and they are not accessible when abdomens have been removed for molecular assays or in dried specimens. Additionally, geometric morphometrics divided intercastes into more discrete phenotype subsets. We conclude that morphometric geometrics are superior to traditional morphometrics techniques for identification and classification of honey bee castes and intermediates.

  9. Morphometric comparisons of Diaphorina citri (Hemiptera: Liviidae) populations from Iran, USA and Pakistan.

    Science.gov (United States)

    Lashkari, Mohammadreza; Hentz, Matthew G; Boykin, Laura M

    2015-01-01

    The Asian citrus psyllid (ACP), Diaphorina citri Kuwayama (Hemiptera: Liviidae), vector of citrus greening disease pathogen, Huanglongbing (HLB), is considered the most serious pest of citrus in the world. Prior molecular based studies have hypothesized a link between the D. citri in Iran and the USA (Florida). The purpose of this study was to collect morphometric data from D. citri populations from Iran (mtCOI haplotype-1), Florida (mtCOI haplotype-1), and Pakistan (mtCOI haplotype-6), to determine whether different mtCOI haplotypes have a relationship to a specific morphometric variation. 240 samples from 6 ACP populations (Iran-Jiroft, Chabahar; Florida-Ft. Pierce, Palm Beach Gardens, Port St. Lucie; and Pakistan-Punjab) were collected for comparison. Measurements of 20 morphological characters were selected, measured and analysed using ANOVA and MANOVA. The results indicate differences among the 6 ACP populations (Wilks' lambda = 0.0376, F = 7.29, P citri species in this study, (1) Iran, (2) USA (Florida) and (3) Pakistan population. Morphometric comparisons provided further resolution to the mtCOI haplotypes and distinguished the Florida and Iranian populations.

  10. Weight and morphometric growth of different strains of tilapia (Oreochromis sp

    Directory of Open Access Journals (Sweden)

    Ivan Bezerra Allaman

    2013-05-01

    Full Text Available The objective of this study was to evaluate the morphometric growth and weight gain of strains of tilapia (Thai, Red, UFLA and Commercial by nonlinear models. Initially, 500 male fingerlings of each strain, at 85 (Red and UFLA and 86 (Thai and Commercial days of age, were stocked separately in raceways with 56 m³. Twenty fish of each strain were randomly sampled, weighed and measured monthly. Five nonlinear models (Brody, von Bertalanffy, Gompertz, logistic and exponential were tested, choosing one that best fit to the data. The variables studied were: weight, standard length (SL, head length (HL, height 1 (H1, height 2 (H2, height 3 (H3, first distance (D1, second distance (D2, first width (W1, second width (W2 and third width (W3. The exponential model had the best fit to weight and morphometric data, with the exception of W2, in which the best fitted model was von Bertalanffy. The convergence of the exponential model to data indicates that the cultivation period studied was not enough for the strains to reach maturity weight. The UFLA strain presented the lowest value for parameter "a" (initial weight estimate, 8.71 g, and the highest for parameter k (specific growth rate, 0.0127, when compared with other evaluated strains. However, the highest k of UFLA was not enough to overcome the final weight observed for the Commercial strain (603.1 g, which was higher than all other strains. Regarding the morphometric measurements, the UFLA strain also had the highest k for the variables SL, HL, HH, H1, H2, H3 and D2, and similar k to Commercial and Thai strains for the variables D1 and W3 respectively. The strains differ as to weight gain and morphometric growth.

  11. Skull shape differentiation of black and white olms (Proteus anguinus anguinus and Proteus a. parkelj): an exploratory analysis with micro-CT scanning

    NARCIS (Netherlands)

    Ivanović, A.; Aljančič, G.; Artzen, J.W.

    2013-01-01

    We performed an exploratory analysis of the morphology of the cranium in the white olm (Proteus anguinus anguinus) and the black olm (P. a. parkelj) with micro-CT scanning and geometric morphometrics. The mudpuppy (Necturus maculosus) was used as an outgroup. The black olm falls outside the white

  12. Morphometrical study of the human kidney. Radiodiagnosis and patological anatomy applications

    International Nuclear Information System (INIS)

    Sampaio, J.B.; Lacerda, C.A.M. de

    1987-01-01

    A morphometrical estimate was made on 100 human kidneys obtained by necropsies. The results of the renal measurements showed the averages of 11.06cm long, 6.24cm wide for the superior pole, 5.42cm wide for the inferior pole, 3.26cm thickness, and 119.48g weight. The left kidney presented a greater lenght, greater width, greater thickness and greater weight than the kidney. The statistical analysis of the correlation between several indices is presented. (author) [pt

  13. Conformation of phylogenetic relationship of Penaeidae shrimp based on morphometric and molecular investigations.

    Science.gov (United States)

    Rajakumaran, P; Vaseeharan, B; Jayakumar, R; Chidambara, R

    2014-01-01

    Understanding of accurate phylogenetic relationship among Penaeidae shrimp is important for academic and fisheries industry. The Morphometric and Randomly amplified polymorphic DNA (RAPD) analysis was used to make the phylogenetic relationsip among 13 Penaeidae shrimp. For morphometric analysis forty variables and total lengths of shrimp were measured for each species, and removed the effect of size variation. The size normalized values obtained was subjected to UPGMA (Unweighted Pair-Group Method with Arithmetic Mean) cluster analysis. For RAPD analysis, the four primers showed reliable differentiation between species, and used correlation coefficient between the DNA banding patterns of 13 Penaeidae species to construct UPGMA dendrogram. Phylogenetic relationship from morphometric and molecular analysis for Penaeidae species found to be congruent. We concluded that as the results from morphometry investigations concur with molecular one, phylogenetic relationship obtained for the studied Penaeidae are considered to be reliable.

  14. Morphometric variations of laelapine mite (Acari: Mesostigmata populations infesting small mammals (Mammalia in Brazil

    Directory of Open Access Journals (Sweden)

    F. Martins-Hatano

    Full Text Available The goal of this study was to evaluate the morphometric variation of laelapine populations (Acari, Mesostigmata associated with neotropical oryzomyine rodents at different geographic localities in Brazil. Three nominal mite species were selected for study, all infesting the pelage of small mammals at different localities in Rio de Janeiro, Espírito Santo, Bahia, and the Federal District, Brazil. To analyse morphometric characteristics, thirty-seven morphological characters distributed across the whole body of each specimen were measured. We use the Analysis of Principal Components, extracting the three first axes and projecting each mite in these axes. Major species level changes in the taxonomy of the host mammals allows an independent examination of morphometric variation of mites infesting a set of distinctly different host species at different geographic localities. Gigantolaelaps vitzthumi and Laelaps differens are associated with oryzomyine rodents of the genus Cerradomys, and consistently showed a tendency to cluster by host phylogeny. Laelaps manguinhosi associated with Nectomys rattus in central Brazil is morphometrically distinct from mites infesting N. squamipes in the coastal restingas of Rio de Janeiro and Espírito Santo. The results obtained here indicate that laelapine mite populations can vary among geographic areas and among phylogenetically related host species. Clearly, the study of these mites at the population level can be an important tool for clarifying the taxonomy of both mites and hosts.

  15. Morphometric variations of laelapine mite (Acari: Mesostigmata) populations infesting small mammals (Mammalia) in Brazil.

    Science.gov (United States)

    Martins-Hatano, F; Gettinger, D; Manhães, M L; Bergallo, H G

    2012-08-01

    The goal of this study was to evaluate the morphometric variation of laelapine populations (Acari, Mesostigmata) associated with neotropical oryzomyine rodents at different geographic localities in Brazil. Three nominal mite species were selected for study, all infesting the pelage of small mammals at different localities in Rio de Janeiro, Espírito Santo, Bahia, and the Federal District, Brazil. To analyse morphometric characteristics, thirty-seven morphological characters distributed across the whole body of each specimen were measured. We use the Analysis of Principal Components, extracting the three first axes and projecting each mite in these axes. Major species level changes in the taxonomy of the host mammals allows an independent examination of morphometric variation of mites infesting a set of distinctly different host species at different geographic localities. Gigantolaelaps vitzthumi and Laelaps differens are associated with oryzomyine rodents of the genus Cerradomys, and consistently showed a tendency to cluster by host phylogeny. Laelaps manguinhosi associated with Nectomys rattus in central Brazil is morphometrically distinct from mites infesting N. squamipes in the coastal restingas of Rio de Janeiro and Espírito Santo. The results obtained here indicate that laelapine mite populations can vary among geographic areas and among phylogenetically related host species. Clearly, the study of these mites at the population level can be an important tool for clarifying the taxonomy of both mites and hosts.

  16. MORPHOMETRIC CHARACTERISTICS OF TROPICAL SHALLOW RESERVOIR USED FOR AQUACULTURE AND AGRICULTURE IN THE MEXICAN PLATEAU

    Directory of Open Access Journals (Sweden)

    Aldama GR

    2013-01-01

    Full Text Available Morphometric characteristics of a tropical shallow reservoir situated in the Southern Mexican Highlands were studied. Seventeen morphometric parameters were measured. Results of the morphometric parameters showed that this reservoir presented a soft and roughness bottom, with an ellipsoid form and a concave depression that allow the mix up of water and sediments, causing turbidity and broken thermal gradients; its slight slopes allowed the colonization of submerged macrophyte and halophyte plants and they improve the incidence of sunlight on water surface increasing evaporation and primary productivity. Tropical shallow reservoirs have fluctuations in area and volume according to the amount of rainfall, the effect of evaporation, the temperature levels, lost of volume due to irrigation, and other causes.

  17. Morphometric characteristics in the horseshoe crab Tachypleus gigas (Arthropoda: Merostomata)

    Digital Repository Service at National Institute of Oceanography (India)

    Vijayakumar, R.; Das, S.; Chatterji, A.; Parulekar, A.H.

    comparative morphometry. This study also emphasizes that care must be taken to apply morphometric for a uniform size group of horseshoe crab populations. It is known that the changes in the form of an animal cannot be described satisfactorily...

  18. Morphometric Changes in the Cortical Microvascular Network in Alzheimer's Disease

    NARCIS (Netherlands)

    Richard, E.; van Gool, W.A.; Hoozemans, J.J.M.; van Haastert, E.S.; Eikelenboom, P.; Rozemuller, A.J.M.; van de Berg, W.D.J.

    2010-01-01

    Alzheimer's disease (AD) pathology is accompanied by abnormalities of the microvasculature. Despite the potential importance of morphometric changes in the cortical capillary network on neuronal dysfunction and cognitive impairment, few autopsy studies have addressed this issue. In the present

  19. Cytological study of DNA content and nuclear morphometric analysis for aid in the diagnosis of high-grade dysplasia within oral leukoplakia.

    Science.gov (United States)

    Yang, Xi; Xiao, Xuan; Wu, Wenyan; Shen, Xuemin; Zhou, Zengtong; Liu, Wei; Shi, Linjun

    2017-09-01

    To quantitatively examine the DNA content and nuclear morphometric status of oral leukoplakia (OL) and investigate its association with the degree of dysplasia in a cytologic study. Oral cytobrush biopsy was carried out to obtain exfoliative epithelial cells from lesions before scalpel biopsy at the same location in a blinded series of 70 patients with OL. Analysis of nuclear morphometry and DNA content status using image cytometry was performed with oral smears stained with the Feulgen-thionin method. Nuclear morphometric analysis revealed significant differences in DNA content amount, DNA index, nuclear area, nuclear radius, nuclear intensity, sphericity, entropy, and fractal dimension (all P content analysis identified 34 patients with OL (48.6%) with DNA content abnormality. Nonhomogeneous lesion (P = .018) and high-grade dysplasia (P = .008) were significantly associated with abnormal DNA content. Importantly, the positive correlation between the degree of oral dysplasia and DNA content status was significant (P = .004, correlation coefficient = 0.342). Cytology analysis of DNA content and nuclear morphometric status using image cytometry may support their use as a screening and monitoring tool for OL progression. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Bio-mechanical and morphometric evaluation of late radiation-induced changes in the mouse rectum

    International Nuclear Information System (INIS)

    Lundby, L.

    1998-01-01

    The overall aim of this thesis was to study the development of late radiation induced damage of the rectum and describe the histopathological and morphometric characteristics of the late injury. This required the design of a new, small probe for rectal measurements of cross-sectional area and distension pressure in mice. The impedance planimetric method was developed and validated in vitro and applied in in vivo studies of normal mice. The study of radiation induced damage of the rectum also required a new set-up for selective irradiation of a specific part of the rectum, shielding other organs. Mice were irradiated with varying single doses and followed with impedance planimetric measurements at regular intervals until death of the animals. In order to compare observed changes of the functional properties of the rectum following irradiation, a description of morphometric and morphologic characteristics by a stereolic technique was planned. A simplified stereological method has been applied to this study to describe late morphometric changes in the different intestinal layers after irradiation with varying single doses. (EG)

  1. Geometric morphometrics in primatology: craniofacial variation in Homo sapiens and Pan troglodytes.

    Science.gov (United States)

    Lynch, J M; Wood, C G; Luboga, S A

    1996-01-01

    Traditionally, morphometric studies have relied on statistical analysis of distances, angles or ratios to investigate morphometric variation among taxa. Recently, geometric techniques have been developed for the direct analysis of landmark data. In this paper, we offer a summary (with examples) of three of these newer techniques, namely shape coordinate, thin-plate spline and relative warp analyses. Shape coordinate analysis detected significant craniofacial variation between 4 modern human populations, with African and Australian Aboriginal specimens being relatively prognathous compared with their Eurasian counterparts. In addition, the Australian specimens exhibited greater basicranial flexion than all other samples. The observed relationships between size and craniofacial shape were weak. The decomposition of shape variation into affine and non-affine components is illustrated via a thin-plate spline analysis of Homo and Pan cranial landmarks. We note differences between Homo and Pan in the degree of prognathism and basicranial flexion and the position and orientation of the foramen magnum. We compare these results with previous studies of these features in higher primates and discuss the utility of geometric morphometrics as a tool in primatology and physical anthropology. We conclude that many studies of morphological variation, both within and between taxa, would benefit from the graphical nature of these techniques.

  2. Morphometric Evaluation of Occipital Condyles: Defining Optimal Trajectories and Safe Screw Lengths for Occipital Condyle-Based Occipitocervical Fixation in Indian Population.

    Science.gov (United States)

    Bosco, Aju; Venugopal, Prakash; Shetty, Ajoy Prasad; Shanmuganathan, Rajasekaran; Kanna, Rishi Mugesh

    2018-04-01

    Computed tomographic (CT) morphometric analysis. To assess the feasibility and safety of occipital condyle (OC)-based occipitocervical fixation (OCF) in Indians and to define anatomical zones and screw lengths for safe screw placement. Limitations of occipital squama-based OCF has led to development of two novel OC-based OCF techniques. Morphometric analysis was performed on the OCs of 70 Indian adults. The feasibility of placing a 3.5-mm-diameter screw into OCs was investigated. Safe trajectories and screw lengths for OC screws and C0-C1 transarticular screws without hypoglossal canal or atlantooccipital joint compromise were estimated. The average screw length and safe sagittal and medial angulations for OC screws were 19.9±2.3 mm, ≤6.4°±2.4° cranially, and 31.1°±3° medially, respectively. An OC screw could not be accommodated by 27% of the population. The safe sagittal angles and screw lengths for C0-C1 transarticular screw insertion (48.9°±5.7° cranial, 26.7±2.9 mm for junctional entry technique; 36.7°±4.6° cranial, 31.6±2.7 mm for caudal C1 arch entry technique, respectively) were significantly different than those in other populations. The risk of vertebral artery injury was high for the caudal C1 arch entry technique. Screw placement was uncertain in 48% of Indians due to the presence of aberrant anatomy. There were significant differences in the metrics of OC-based OCF between Indian and other populations. Because of the smaller occipital squama dimensions in Indians, OC-based OCF techniques may have a higher application rate and could be a viable alternative/salvage option in selected cases. Preoperative CT, including three-dimensional-CT-angiography (to delineate vertebral artery course), is imperative to avoid complications resulting from aberrant bony and vascular anatomy. Our data can serve as a valuable reference guide in placing these screws safely under fluoroscopic guidance.

  3. Geometric morphometric footprint analysis of young women

    OpenAIRE

    Domjanic, Jacqueline; Fieder, Martin; Seidler, Horst; Mitteroecker, Philipp

    2013-01-01

    Background Most published attempts to quantify footprint shape are based on a small number of measurements. We applied geometric morphometric methods to study shape variation of the complete footprint outline in a sample of 83 adult women. Methods The outline of the footprint, including the toes, was represented by a comprehensive set of 85 landmarks and semilandmarks. Shape coordinates were computed by Generalized Procrustes Analysis. Results The first four principal components represented t...

  4. [Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3 Tesla magnetic resonance images].

    Science.gov (United States)

    Alberich-Bayarri, A; Martí-Bonmatí, L; Sanz-Requena, R; Sánchez-González, J; Hervás Briz, V; García-Martí, G; Pérez, M Á

    2014-01-01

    We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT). We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2D fractal dimension (D(2D)), the 3D fractal dimension (D(3D)), and the elastic module in the three spatial directions (Ex, Ey and Ez). The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (μCT) was high, with errors less than 15% for BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z. Our experimental results in animals confirm that the parameters of BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  5. Energy-related parameters and their association with age, gender, and morphometric measurements in healthy donkeys.

    Science.gov (United States)

    Mendoza, F J; Estepa, J C; Gonzalez-De Cara, C A; Aguilera-Aguilera, R; Toribio, R E; Perez-Ecija, A

    2015-05-01

    Donkeys are commonly afflicted by endocrine and metabolic disturbances but few studies have investigated endocrine variables involved in energy regulation and their association with morphometric indices, age or gender in this species. Hemostatic and clinical differences have been demonstrated between horses and donkeys, so to consider both species as metabolically and endocrinologically similar could lead to misdiagnosis. In this study, plasma concentrations of glucose, triglycerides and endocrine factors involved in energy homeostasis (insulin, glucagon, leptin, adiponectin, ghrelin and insulin-like growth factor [IGF]-1) were measured and their association with morphometric variables (body condition score, neck scoring and body mass index), gender and age was determined in 62 healthy donkeys. In addition, a neck scoring system specific for donkeys was developed. Insulin, glucagon, leptin and IGF-1 concentrations were found to be similar between donkeys and other species, but adiponectin and active ghrelin were lower in donkeys than horses. Donkeys with larger neck scores and body mass indices had higher triglyceride, leptin and IGF-1 concentrations. A sexual dimorphism was observed on all morphometric measurements and plasma glucose concentrations independent of adiposity. Younger animals had lower morphometric measurements and triglyceride and leptin concentrations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Effect of Urtica dioica on morphometric indices of kidney in streptozotocin diabetic rats--a stereological study.

    Science.gov (United States)

    Golalipour, Mohammad Jafar; Gharravi, Anneh Mohammad; Ghafari, Sorya; Afshar, Mohammad

    2007-11-01

    The aim of the present study was to investigate the effect of Urtica dioica on Morphometric indices of kidney in diabetic rats. Thirty male adult albino wistar rats of 125-175 g divided into control, diabetic and Urtica dioica treatment groups. In treatment Group, diabetic rats received 100 mg kg(-1) daily hydroalcoholic extract of U. dioica intraperitoneally for 4 weeks. After the animals had been sacrified, the kidneys were removed and fixed by formaldehyde, cut horizontally into 1 mm slices and processed, Stained with H and E. Stereological study performed using light microscope and the image projected on a table of olysa software. Cavalieri principle was used to estimate the volume of cortex, medulla and whole kidney. All the grouped data statistically evaluated using Student's t-test, expressed as the Mean +/- SE. Ration of kidney weight/body weight in diabetes (0.51) and diabetes-extract group (0.67) were higher then control group (0.42). Ratio of kidney volume/body weight in diabetes (350) and diabetes-extract group (348) were higher then control group (323). Volume Ratio of cortex/medulla in diabetes-extract group (1.65) was higher then control (1.34) and diabetes group (1.33). Glomerular area and diameter and proximal tubule diameter in diabetes-Extract group was higher than control and diabetes groups. This study revealed that Urtica dioica has no effect on renal morphometric indices in induced diabetic rats.

  7. A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image

    International Nuclear Information System (INIS)

    Han, Seung Yun; Lee, Sun Bok; Oh, Sung Ook; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; Kim, Jong Dae

    2003-01-01

    To evaluate the relationship between morphometric analysis of microstructure from digital radiographic image and trabecular bone strength. One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI(100 x 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p<0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  8. Morphometric variations of three species of harvested cephalopods found in northern sea of Aceh Province, Indonesia

    Directory of Open Access Journals (Sweden)

    ZAINAL ABIDIN MUCHLISIN

    2014-10-01

    Full Text Available Muchlisin ZA, Zulkarnaini B, Purnawan S, Muhadjier A, Fadli N, Cheng SH. 2014. Morphometric variations of three species of harvested cephalopods found in northern sea of Aceh Province, Indonesia. Biodiversitas 15: 142-146. The purpose of the present study was to evaluate the morphometrics of three harvested cephalopods, Sepioteuthis lessoniana, Sepia officinalis and Uroteuthis sp. found in northern sea of Aceh Province, Indonesia. Sampling was conducted for six months from July to December 2012 in one week interval. A total of 318 cephalopods; 139 Sepioteuthis lessoniana, 139 Uroteuthis sp. and 40 Sepia officinalis were analyzed for morphometric study and 13 anatomical characters were measured to the nearest 0.01 mm using a digital calipers. Morphometric measurements were significantly different between the different species of cephalopods (ANOVA, p<0.05. S. officinalis differed in six morphological characters (head length, head width, tentacles length, gladius width, rancis width and length from the squid species. Fin width and length were significantly greater in S. lessoniana than in S. officinalis and Uroteuthis sp. On the other hand, Uroteuthis sp. had significantly greater mantle lengths, standard lengths and gladius lengths than the other two cephalopod species (Duncan Test, p<0.05. However, fin width was similar between S. lessoniana and Uroteuthis sp., while eye diameter was similar between S. officinalis and Uroteuthis sp. A Discriminant Function Analysis scatter plot successfully discriminated the three species indicating significant differences in morphological variation. This analysis also indicates that morphometrically, S. lessoniana and S. officinalis are more similar to each other despite being in different orders.

  9. Geoinformatics for assessing the morphometric control on ...

    Indian Academy of Sciences (India)

    natural disasters are one of the serious geo-hazards, ... Natural features such as land use and land cover, soil and .... steps followed for the generation of morphometric ... language. Infiltration number. Area, perimeter, basin length, min & max.

  10. Acute pulmonary emphysema in death by hanging: a morphometric digital study.

    Science.gov (United States)

    Castiglioni, Claudia; Baumann, Pia; Fracasso, Tony

    2016-09-01

    Acute pulmonary emphysema (APE) has been described in cases of mechanical asphyxia such as ligature or manual strangulation but not in cases of hanging. In this study, we wanted to verify by morphometric digital analysis of lung tissue whether APE occurs in death by hanging.We investigated 16 cases of hanging (eight complete, eight incomplete), 10 cases of freshwater drowning (positive control group), and 10 cases of acute external bleeding (negative control group). Tissue sections were obtained from each pulmonary lobe. For each slide, five fields were randomly selected. The area of every alveolar space was measured by image analysis software. The mean alveolar area (MAA) was calculated for each group.In incomplete hanging, MAA was significantly higher than that observed in complete hanging and similar to the one observed in freshwater drowning.APE in cases of incomplete hanging can be considered as a sign of vitality. The high number of conditions that can cause alveolar distension (that were excluded in this study) limits the applicability of this vital sign in the routine forensic practice.

  11. Genetic parameters and trends of morphometric traits of GIFT tilapia under selection for weight gain

    Directory of Open Access Journals (Sweden)

    Rafael Vilhena Reis Neto

    2014-08-01

    Full Text Available The main factor considered in breeding programs for fish is growth, which can be assessed in terms of a gain in either weight or body measurements. This study was undertaken to evaluate the morphometric traits of GIFT strain tilapia (Oreochromis sp. selected for weight gain. The data set used contained information on 6,650 animals. The genetic values of 8,590 animals in a relationship matrix of five generations were predicted. The following morphometric measurements were evaluated: standard length; body depth and body width. Body area and volume were also calculated. Bi-character analyses involving morphometric traits were used to estimate (covariance components. Heritability, larval and fingerling common environmental effects were estimated for each trait, together with the genetic and phenotypic correlations between traits. Bayesian procedures were utilised by Gibbs chains, and the convergence of the chains was tested using the Heidelberger and Welch method. Genetic trends were estimated by segmented regression of the fish breeding values of the generations considered in this study. Estimates of heritability (0.28 a 0.31 had moderate to high magnitudes for all traits. Genetic correlations between traits were all above 0.8, and the genetic gains were satisfactory from the third generation onwards. From the estimates of the genetic parameters and genetic gain the morphometric traits evaluated have good potential for selection.

  12. Morphometric relations of fractal-skeletal based channel network model

    Directory of Open Access Journals (Sweden)

    B. S. Daya Sagar

    1998-01-01

    Full Text Available A fractal-skeletal based channel network (F-SCN model is proposed. Four regular sided initiator-basins are transformed as second order fractal basins by following a specific generating mechanism with non-random rule. The morphological skeletons, hereafter referred to as channel networks, are extracted from these fractal basins. The morphometric and fractal relationships of these F-SCNs are shown. The fractal dimensions of these fractal basins, channel networks, and main channel lengths (computed through box counting method are compared with those of estimated length–area measures. Certain morphometric order ratios to show fractal relations are also highlighted.

  13. Morphological changes of carotid bodies in acute respiratory distress syndrome: a morphometric study in humans

    Directory of Open Access Journals (Sweden)

    Vinhaes E.N.G.

    2002-01-01

    Full Text Available Carotid bodies are chemoreceptors sensitive to a fall of partial oxygen pressure in blood (hypoxia. The morphological alterations of these organs in patients with chronic obstructive pulmonary disease (COPD and in people living at high altitude are well known. However, it is not known whether the histological profile of human carotid bodies is changed in acute clinical conditions such as acute respiratory distress syndrome (ARDS. The objective of the present study was to perform a quantitative analysis of the histology of carotid bodies collected from patients who died of ARDS. A morphometric study of carotid bodies collected during routine autopsies was carried out on three groups: patients that died of non-respiratory diseases (controls, N = 8, patients that presented COPD and died of its complications or associated diseases (N = 7, and patients that died of ARDS (N = 7. Morphometric measurements of the volume fraction of clusters of chief cells were performed in five fields on each slide at 40X magnification. The numerical proportion of the four main histological cell types (light, dark, progenitor and sustentacular cells was determined analyzing 10 fields on each slide at 400X magnification. The proportion of dark cells was 0.22 in ARDS patients, 0.12 in controls (P<0.001, and 0.08 in the COPD group. The proportion of light cells was 0.33 (ARDS, 0.44 (controls (P<0.001, and 0.36 (COPD. These findings suggest that chronic and acute hypoxia have different effects on the histology of glomic tissue.

  14. Bat Species Comparisons Based on External Morphology: A Test of Traditional versus Geometric Morphometric Approaches.

    Science.gov (United States)

    Schmieder, Daniela A; Benítez, Hugo A; Borissov, Ivailo M; Fruciano, Carmelo

    2015-01-01

    External morphology is commonly used to identify bats as well as to investigate flight and foraging behavior, typically relying on simple length and area measures or ratios. However, geometric morphometrics is increasingly used in the biological sciences to analyse variation in shape and discriminate among species and populations. Here we compare the ability of traditional versus geometric morphometric methods in discriminating between closely related bat species--in this case European horseshoe bats (Rhinolophidae, Chiroptera)--based on morphology of the wing, body and tail. In addition to comparing morphometric methods, we used geometric morphometrics to detect interspecies differences as shape changes. Geometric morphometrics yielded improved species discrimination relative to traditional methods. The predicted shape for the variation along the between group principal components revealed that the largest differences between species lay in the extent to which the wing reaches in the direction of the head. This strong trend in interspecific shape variation is associated with size, which we interpret as an evolutionary allometry pattern.

  15. Bat Species Comparisons Based on External Morphology: A Test of Traditional versus Geometric Morphometric Approaches.

    Directory of Open Access Journals (Sweden)

    Daniela A Schmieder

    Full Text Available External morphology is commonly used to identify bats as well as to investigate flight and foraging behavior, typically relying on simple length and area measures or ratios. However, geometric morphometrics is increasingly used in the biological sciences to analyse variation in shape and discriminate among species and populations. Here we compare the ability of traditional versus geometric morphometric methods in discriminating between closely related bat species--in this case European horseshoe bats (Rhinolophidae, Chiroptera--based on morphology of the wing, body and tail. In addition to comparing morphometric methods, we used geometric morphometrics to detect interspecies differences as shape changes. Geometric morphometrics yielded improved species discrimination relative to traditional methods. The predicted shape for the variation along the between group principal components revealed that the largest differences between species lay in the extent to which the wing reaches in the direction of the head. This strong trend in interspecific shape variation is associated with size, which we interpret as an evolutionary allometry pattern.

  16. CT study in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji [Tokyo Metropolitan Matsuzawa Hospital (Japan)

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, II and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefore, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease.

  17. CT study in Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, Ii and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefor, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease. (J.P.N.)

  18. The potential of statistical shape modelling for geometric morphometric analysis of human teeth in archaeological research.

    Science.gov (United States)

    Woods, Christopher; Fernee, Christianne; Browne, Martin; Zakrzewski, Sonia; Dickinson, Alexander

    2017-01-01

    This paper introduces statistical shape modelling (SSM) for use in osteoarchaeology research. SSM is a full field, multi-material analytical technique, and is presented as a supplementary geometric morphometric (GM) tool. Lower mandibular canines from two archaeological populations and one modern population were sampled, digitised using micro-CT, aligned, registered to a baseline and statistically modelled using principal component analysis (PCA). Sample material properties were incorporated as a binary enamel/dentin parameter. Results were assessed qualitatively and quantitatively using anatomical landmarks. Finally, the technique's application was demonstrated for inter-sample comparison through analysis of the principal component (PC) weights. It was found that SSM could provide high detail qualitative and quantitative insight with respect to archaeological inter- and intra-sample variability. This technique has value for archaeological, biomechanical and forensic applications including identification, finite element analysis (FEA) and reconstruction from partial datasets.

  19. Morphometric traits in arbor-acres broiler chicken ( Gallus gallus )fed ...

    African Journals Online (AJOL)

    Fifty sixth day morphometric and body weight measurements were taken on one hundred and forty eight Arbor Acres broiler chickens reared under the Deep Litter system in the guinea savana Zone of Nigeria. This study aimed to determine the effects of substituting treated and untreated Cocoa Bean Shell (CBS) at 50 and ...

  20. Effects of Temperature, Photoperiod, and Rainfall on Morphometric Variation of Diaphorina citri (Hemiptera: Liviidae).

    Science.gov (United States)

    Paris, Thomson M; Allan, Sandra A; Hall, David G; Hentz, Matthew G; Croxton, Scott D; Ainpudi, Niharika; Stansly, Philip A

    2017-02-01

    Phenotypic plasticity provides a mechanism by which an organism can adapt to new or changing environments. Earlier studies have demonstrated the variability of Diaphorina citri Kuwayama (Asian citrus psyllid) population dynamics, but no analysis of morphological changes induced by seasonal or artificial laboratory-induced conditions has yet been documented. Such morphometric variation has been found to correspond in dispersal capabilities in several insect taxa. In this study, the effects of temperature and photoperiod on morphometric variation of D. citri were examined through laboratory rearing of psyllids under controlled temperatures (20 °C, 28 °C, and 30 °C) and under a short photoperiod of 10.5:13.5 (L:D) h and a long photoperiod of 16:8 (L:D) h. Diaphorina citri were field-collected monthly from three citrus groves in Fort Pierce, Gainesville, and Immokalee, FL, to evaluate potential field-associated environmental effects. Both traditional and geometric morphometric data were used to analyze the correlation between environmental and morphometric variation. A strong correlation was found between temperature and shape change, with larger and broader wings at colder temperatures in the laboratory. Short day length resulted in shorter and narrower wings as well. From the field, temperature, rainfall, and photoperiod were moderately associated with shape parameters. Adult D. citri with blue/green abdomens collected in the laboratory and field studies were larger in size and shape than those with brown/gray abdomens. Published by Oxford University Press on behalf of Entomological Society of America 2016. This work is written by US Government employees and is in the public domain in the US.

  1. Pelvic Floor Morphometric Differences in Elderly Women with or without Urinary Incontinence.

    Science.gov (United States)

    Fradet, Sarah; Morin, Mélanie; Kruger, Jennifer; Dumoulin, Chantale

    2018-01-01

    Purpose: Urinary incontinence (UI) affects as many as 50% of women aged 60 years and older, but UI pathophysiology, specifically in elderly women, remains unclear. A better understanding of morphometric differences between continent and urinary incontinent elderly women is needed to improve the effectiveness of conservative treatment approaches. We hypothesized that morphometric differences in the pelvic floor muscles (PFM) among elderly women with and without UI could be observed using three- and four-dimensional (3D/4D) transperineal ultrasound (TPU) imaging. Method: A total of 40 elderly women (20 women with and 20 women without UI), with a mean age of 67.10 (SD 4.94) years, participated in the study. This was a case-control study in which TPU images were taken under three conditions: rest, maximal voluntary contraction (MVC), and Valsalva. Independent t -tests were conducted to compare measurements between the groups. Results: The study revealed statistically significant differences between the groups. At rest, the levator hiatal area and transverse diameter were bigger, and the PFM position was lower in the incontinent group. During MVC, all axial plane parameters were bigger in the incontinent group. In the sagittal plane, PFM position was again lower in the incontinent group. During Valsalva, the anorectal angle was wider in the women with incontinence. Conclusion: PFM morphometric differences were present and were observed using 3D/4D TPU imaging in elderly women with and without UI.

  2. Morphometric study of the Habo dome, Kachchh, Gujarat, India: implications on neotectonic activity

    Science.gov (United States)

    Bhattacharjee, N.; Mohanty, S. P.

    2017-12-01

    The Kachchh Basin of western India was developed during the separation of the Indian plate from the Gondwanaland in Mesozoic. Series of E-W striking master faults were generated during this extensional phase. The collision of the Indian and Eurasian plates in Eocene time resulted in the change of stress regime to a compressional setting when the built-up stress developed NNW-SSE to NNE-SSW striking transverse faults and reactivated the earlier E-W master faults. The present work was carried out in the Habo dome, located in the central part of the Kachchh Basin, to analyse the morphometric features such as the bifurcation ratio, circulation ratio, drainage texture, asymmetric factor, hypsometric indices and mountain front sinuosity of selected sub-watersheds of the area to understand the effects of fault reactivation and neotectonic activities on the geometry of the dome. Shuttle Radar Topographic Mission (SRTM) Digital Elevation Model (DEM) data were used to extract drainage network for morphometric analysis of the Kaswati, Khari, and Pur river basins. The study area is elliptical in outline with the long axis trending approximately E-W. The evolution of this domal structure is interpreted to be the result of fault-bound nature of the block. The northern slope of the dome is bound by the Kachchh Mainland Fault and the eastern and western boundaries are marked by transverse faults. The undulating topography was developed by differential movements along several transverse faults striking NW-SE, N-S, and NE-SW. The earlier interpretation of laccolith intrusion into the sedimentary rocks is not supported by the data analysis and field mapping. Stress propagations from the Himalayan range in the northeast and Sulaiman range in the northwest are identified to be the causative factor for historical seismicity and drainage anomalies in the area. Keywords: Basin morphometry, Geographical Information System, Lineament patterns, Kachchh basin, Neotectonics, Fault reactivation

  3. Application of Multilevel Models to Morphometric Data. Part 2. Correlations

    Directory of Open Access Journals (Sweden)

    O. Tsybrovskyy

    2003-01-01

    Full Text Available Multilevel organization of morphometric data (cells are “nested” within patients requires special methods for studying correlations between karyometric features. The most distinct feature of these methods is that separate correlation (covariance matrices are produced for every level in the hierarchy. In karyometric research, the cell‐level (i.e., within‐tumor correlations seem to be of major interest. Beside their biological importance, these correlation coefficients (CC are compulsory when dimensionality reduction is required. Using MLwiN, a dedicated program for multilevel modeling, we show how to use multivariate multilevel models (MMM to obtain and interpret CC in each of the levels. A comparison with two usual, “single‐level” statistics shows that MMM represent the only way to obtain correct cell‐level correlation coefficients. The summary statistics method (take average values across each patient produces patient‐level CC only, and the “pooling” method (merge all cells together and ignore patients as units of analysis yields incorrect CC at all. We conclude that multilevel modeling is an indispensable tool for studying correlations between morphometric variables.

  4. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    International Nuclear Information System (INIS)

    Bartalena, Tommaso; Giannelli, Giovanni; Rinaldi, Maria Francesca; Rimondi, Eugenio; Rinaldi, Giovanni; Sverzellati, Nicola; Gavelli, Giampaolo

    2009-01-01

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  5. BIOCHEMICAL AND MORPHOMETRIC PARAMETERS OF PRE-LARVAE OF THREE SALMONIDS SPECIES AT ONE-DAY AGE

    Directory of Open Access Journals (Sweden)

    Ye. Barylo

    2016-06-01

    Full Text Available Purpose. To study and analyze the morphometric and some biochemical parameters of pre-larval brown trout, rainbow trout and brook trout in post-embryonic period under the conditions of "Rybnyi Potik” farm in the Transcarpathian region for further use of the obtained data in scientific and practical works related to the cultivation of the juveniles of valuable salmonid species. Methodology. One-day free embryos (pre-larvae of brown trout, rainbow trout and brook trout we used as study materials. Morphometric parameters we studied by the methods of N. O. Lange, E. N. Dmitrieva. The content of total lipids was determined in accordance with Folch. in the tissuesm, which were taken for biochemical studies. Separate classes of lipids were received by thin layer chromatography. Findings. We carried out a comparative analysis of morphometric measurements and biochemical parameters of one-day pre-larval brown trout, rainbow trout and brook trout based on the obtained data. We investigated morphometric and biochemical specific features of pre-larvae in post-embryonic period and showed the species differences of morphometric measurements. Significant differences were observed between the content of lipids in the body and yolk sac of free embryos. In particular, a higher content of phospholipids and triglycerides was observed in the body of brook trout compared to brown trout. We also recorded higher contents of mono- and diacylglycerols, free cholesterol, non-etherified fatty acids (NEFA, triacylglycerols and cholesterol esters in the yolk sac of brook trout. Compared to brown trout, rainbow trout had a significant increase in mono- and diacylglycerols, free cholesterol and NEFA in both body and yolk sac as well higher levels of total lipids, triacylglycerols and cholesterol esters were registered in yolk sac. Originality. For the first time we carried out and compared the specific features of pre-larval brown trout, rainbow trout and brook trout in the

  6. Monthly morphometric data on captive Kemps ridley sea turtles from 1998-2014 (NCEI Accession 0156880)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data contains monthly morphometric measurements on captive reared sea turtles at the Galveston, TX NOAA lab. Morphometric measurements are taken to track growth...

  7. Computed Tomography-Based Occipital Condyle Morphometry in an Indian Population to Assess the Feasibility of Condylar Screws for Occipitocervical Fusion.

    Science.gov (United States)

    Srivastava, Abhishek; Nanda, Geetanjali; Mahajan, Rajat; Nanda, Ankur; Mishra, Nirajana; Karmaran, Srinivasa; Batra, Sahil; Chhabra, Harvinder Singh

    2017-12-01

    A retrospective computed tomography (CT)-based morphometric study of 82 occipital condyles in the Indian population, focusing on critical morphometric dimensions with relation to placing condylar screws. This study focused on determining the feasibility of placing occipital condylar screws in an Indian population using CT anatomical morphometric data. The occipital condylar screw is a novel technique being explored as one of the options in occipitocervical stabilization. Sex and ethnic variations in anatomical structures may restrict the feasibility of this technique in some populations. To the best of our knowledge, there are no CT-based data on an Indian population that assess the feasibility of occipital condylar screws. We measured the dimensions of 82 occipital condyles in 41 adults on coronal, sagittal, and axial reconstructed CT images. The differences were noted between the right and left sides and also between males and females. Statistical analysis was performed using the t -test, with a p -value of occipital condyle shows that condylar screws are anatomically feasible in a large portion of the Indian population. However, because a small number of population may not be suitable for this technique, meticulous study of preoperative anatomy using detailed CT data is advised.

  8. Geospatial tool-based morphometric analysis using SRTM data in Sarabanga Watershed, Cauvery River, Salem district, Tamil Nadu, India

    Science.gov (United States)

    Arulbalaji, P.; Gurugnanam, B.

    2017-11-01

    A morphometric analysis of Sarabanga watershed in Salem district has been chosen for the present study. Geospatial tools, such as remote sensing and GIS, are utilized for the extraction of river basin and its drainage networks. The Shuttle Radar Topographic Mission (SRTM-30 m resolution) data have been used for morphometric analysis and evaluating various morphometric parameters. The morphometric parameters of Sarabanga watershed have been analyzed and evaluated by pioneer methods, such as Horton and Strahler. The dendritic type of drainage pattern is draining the Sarabanga watershed, which indicates that lithology and gentle slope category is controlling the study area. The Sarabanga watershed is covered an area of 1208 km2. The slope of the watershed is various from 10 to 40% and which is controlled by lithology of the watershed. The bifurcation ratio ranges from 3 to 4.66 indicating the influence of geological structure and suffered more structural disturbances. The form factor indicates elongated shape of the study area. The total stream length and area of watershed indicate that mean annual rainfall runoff is relatively moderate. The basin relief expressed that watershed has relatively high denudation rates. The drainage density of the watershed is low indicating that infiltration is more dominant. The ruggedness number shows the peak discharges that are likely to be relatively higher. The present study is very useful to plan the watershed management.

  9. Foot morphometric phenomena.

    Science.gov (United States)

    Agić, Ante

    2007-06-01

    Knowledge of the foot morphometry is important for proper foot structure and function. Foot structure as a vital part of human body is important for many reasons. The foot anthropometric and morphology phenomena are analyzed together with hidden biomechanical descriptors in order to fully characterize foot functionality. For Croatian student population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot morphometric descriptors are influenced by many factors, such as life style, climate, and things of great importance in human society. Dominant descriptors related to fit and comfort are determined by the use 3D foot shape and advanced foot biomechanics. Some practical recommendations and conclusions for medical, sportswear and footwear practice are highlighted.

  10. A geometric morphometric assessment of the optic cup in glaucoma.

    Science.gov (United States)

    Sanfilippo, Paul G; Cardini, Andrea; Sigal, Ian A; Ruddle, Jonathan B; Chua, Brian E; Hewitt, Alex W; Mackey, David A

    2010-09-01

    The morphologic appearance of the optic disc is of interest in glaucoma. In contrast to descriptive classification systems that are currently used, a quantitative approach to the analysis of optic disc morphology is required. Our goal was to determine the optimal method for quantifying optic cup shape by comparing traditional (ovality, form-factor and neuroretinal rim (NRR) width ratio) and geometric morphometric approaches. Left optic disc stereophotographs of 160 (80 normal and 80 glaucomatous (stratified by severity)) subjects were examined. The optic cup margins were stereoscopically delineated with a custom tracing system and saved as a series of discrete points. The geometric morphometric methods of elliptic Fourier analysis (EFA) and sliding semi-landmark analysis (SSLA) were used to eliminate variation unrelated to shape (e.g. size) and yield a series of shape variables. Differences in optic cup shape between normal and glaucoma groups were investigated. Discriminant functions were computed and the sensitivity and specificity of each technique determined. Receiver operator characteristic (ROC) curves were calculated for all methods and evaluated in their potential to discriminate between normal and glaucomatous eyes based on the shape variables. All geometric morphometric methods revealed differences between normal and glaucomatous eyes in optic cup shape, in addition to the traditional parameters of ovality, form-factor and NRR width ratio (pgeometric morphometric approach for discriminating between normal and glaucomatous eyes in optic cup shape is superior to that provided by traditional single parameter shape measures. Such analytical techniques could be incorporated into future automated optic disc screening modalities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  11. The experimental study of sinal wall thickening on CT

    International Nuclear Information System (INIS)

    Kase, Yasuhiro; Iinuma, Tositaka; Oyama, Kazuyuki.

    1988-01-01

    In our previous report, we investigated several factors which cause apparent thickening of the walls of maxillary sinus. We confirmed, however, that the major factor for the sinal wall thickening is the artifact of CT. In present study, we report the results obtained by phantom models of isolated maxillary bone and egg shell. As the substance corresponding to the soft tissue density, solutions of CaCl 2 in various concentrations were used. In the maxillary bone studies, the thickness of the anterior sinus wall by CT was larger than the actual value even though only the air was contained. When solutions of CaCl 2 were contained and in touch with the anterior wall, the thickness by CT was larger than that of containing air. In the egg shell studies, the increase in thickness by CT correlated to the increase in percentage of solutions. The above results indicate that the apparent increased thickness of the sinal walls by CT is largely the artifact by CT and is dependent upon the soft tissue density or CT value (X-ray attenuation coefficient) of substances in touch with the sinal walls. In CT images obtained by clinical cases, the increased thickness of the sinal walls, in sinuses filled with soft tissue density, is more apparent than real. (author)

  12. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  13. Morphometric analysis of cinder cones on Tenerife (Canary Islands, Spain): results and applications

    International Nuclear Information System (INIS)

    Doniz Paez, F. J.

    2009-01-01

    This paper applied morphometric to the cinder cones of Tenerife. The technical morphometric allows to establish simple models of morphology, and size to the most frequent volcanoes of Tenerife's mafic volcanism. The obtained classification allow to distinguish four morphological types of scoria cones and three size groups, which is also extended to other volcanic regions. (Author) 5 refs.

  14. Morphometric variation of the Herichthys bartoni (Bean, 1892 species group (Teleostei: Cichlidae: How many species comprise H. labridens (Pellegrin, 1903?

    Directory of Open Access Journals (Sweden)

    Omar Mejía

    Full Text Available Cichlids of the tribe Heroini have long been a source of taxonomical conflict. In particular, the species included in the Herichthys bartoni group have failed to be recovered as monophyletic in different molecular studies. In this paper we use traditional and geometric morphometrics to evaluate morphological variation in the species included in the H. bartoni complex in order to evaluate the number of species it contains. An update of a previously published DNA barcoding study suggests the existence of three genetic clusters that included the six recognized species analyzed in this study, none of them recovered as monophyletic. On the other hand, geometric morphometrics arise as a useful tool to discriminate species due that traditional morphometrics showed a high overlap in the characters analyzed that prevents the proposal of diagnostic characters.

  15. The potential of statistical shape modelling for geometric morphometric analysis of human teeth in archaeological research.

    Directory of Open Access Journals (Sweden)

    Christopher Woods

    Full Text Available This paper introduces statistical shape modelling (SSM for use in osteoarchaeology research. SSM is a full field, multi-material analytical technique, and is presented as a supplementary geometric morphometric (GM tool. Lower mandibular canines from two archaeological populations and one modern population were sampled, digitised using micro-CT, aligned, registered to a baseline and statistically modelled using principal component analysis (PCA. Sample material properties were incorporated as a binary enamel/dentin parameter. Results were assessed qualitatively and quantitatively using anatomical landmarks. Finally, the technique's application was demonstrated for inter-sample comparison through analysis of the principal component (PC weights. It was found that SSM could provide high detail qualitative and quantitative insight with respect to archaeological inter- and intra-sample variability. This technique has value for archaeological, biomechanical and forensic applications including identification, finite element analysis (FEA and reconstruction from partial datasets.

  16. Discrete tomography in an in vivo small animal bone study.

    Science.gov (United States)

    Van de Casteele, Elke; Perilli, Egon; Van Aarle, Wim; Reynolds, Karen J; Sijbers, Jan

    2018-01-01

    This study aimed at assessing the feasibility of a discrete algebraic reconstruction technique (DART) to be used in in vivo small animal bone studies. The advantage of discrete tomography is the possibility to reduce the amount of X-ray projection images, which makes scans faster and implies also a significant reduction of radiation dose, without compromising the reconstruction results. Bone studies are ideal for being performed with discrete tomography, due to the relatively small number of attenuation coefficients contained in the image [namely three: background (air), soft tissue and bone]. In this paper, a validation is made by comparing trabecular bone morphometric parameters calculated from images obtained by using DART and the commonly used standard filtered back-projection (FBP). Female rats were divided into an ovariectomized (OVX) and a sham-operated group. In vivo micro-CT scanning of the tibia was done at baseline and at 2, 4, 8 and 12 weeks after surgery. The cross-section images were reconstructed using first the full set of projection images and afterwards reducing them in number to a quarter and one-sixth (248, 62, 42 projection images, respectively). For both reconstruction methods, similar changes in morphometric parameters were observed over time: bone loss for OVX and bone growth for sham-operated rats, although for DART the actual values were systematically higher (bone volume fraction) or lower (structure model index) compared to FBP, depending on the morphometric parameter. The DART algorithm was, however, more robust when using fewer projection images, where the standard FBP reconstruction was more prone to noise, showing a significantly bigger deviation from the morphometric parameters obtained using all projection images. This study supports the use of DART as a potential alternative method to FBP in X-ray micro-CT animal studies, in particular, when the number of projections has to be drastically minimized, which directly reduces

  17. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  18. Landmark-based geometric morphometric analysis of wing shape among certain species of Aedes mosquitoes in District Dehradun (Uttarakhand), India.

    Science.gov (United States)

    Mondal, Ritwik; Devi, N Pemola; Jauhari, R K

    2015-06-01

    Insect wing morphology has been used in many studies to describe variations among species and populations using traditional morphometrics, and more recently geometric morphometrics. A landmark-based geometric morphometric analysis of the wings of three species of Aedes (Diptera: Culicidae), viz. Ae. aegypti, Ae. albopictus and Ae. pseudotaeniatus, at District Dehradun was conducted belling on the fact that it can provide insight into the population structure, ecology and taxonomic identification. Adult Aedes mosquito specimens were randomly collected using aerial nets and morphologically examined and identified. The landmarks were identified on the basis of landmark based geometric morphometric analysis thin-plate spline (mainly the software tps-Util 1.28; tps-Dig 1.40; tps-Relw 1.53; and tps-Spline 1.20) and integrated morphometrics programme (mainly twogroup win8 and PCA win8) were utilized. In relative warp (RW) analysis, the first two RW of Ae. aegypti accounted for the highest value (95.82%), followed by Ae. pseudotaeniatus (90.89%), while the lowest (90.12%) being recorded for Ae. albopictus. The bending energies of Ae. aegypti and Ae. pseudotaeniatus were quite identical being 0.1882 and 0.1858 respectively, while Ae. albopictus recorded the highest value of 0.9774. The mean difference values of the distances among Aedes species performing Hotelling's T 2 test were significantly high, predicting major differences among the taxa. In PCA analysis, the horizontal and vertical axis summarized 52.41 and 23.30% of variances respectively. The centroid size exhibited significant differences among populations (non-parametric Kruskal-Wallis test, H = 10.56, p < 0.01). It has been marked out that the geometric morphometrics utilizes powerful and comprehensive statistical procedures to analyze the shape differences of a morphological feature, assuming that the studied mosquitoes may represent different genotypes and probably come from one diverse gene pool.

  19. A morphometry map and a new method for honey bee morphometric analysis by using the ArcGIS

    Directory of Open Access Journals (Sweden)

    Hossam F. Abou-Shaara

    2013-12-01

    Full Text Available The morphometric analysis of honey bees has a substantial importance for honey bee subspecies characterization and discrimination while the ArcGIS is a geographical program for data analysis. In the present research, the combination between the morphometric data and the spatial analysis options of the ArcGIS was done and subsequently tested in creating a morphometry map for honey bees from some regions in Egypt as well as for the discrimination between two honey bee subspecies. Therefore, I present a model for creating the morphometry maps and a new method for the morphometric analysis by the transformation of the morphometric data to raster data layers. The obtained results showed that the created morphometry map classified the regions successfully according to the morphological character means. The morphometric analysis was successfully performed by using trend analysis and raster difference range. The analysis of the morphometric data as raster layers showed high sensitivity for the differences between subspecies and regions. The presented model and the method are effective and can be applied for the discrimination between subspecies, regions and colonies as well as can be used with other insects.

  20. Host-based identification is not supported by morphometrics in natural populations of Gyrodactylus salaris and G. thymalli (Platyhelminthes, Monogenea).

    Science.gov (United States)

    Olstad, K; Shinn, A P; Bachmann, L; Bakke, T A

    2007-12-01

    Gyrodactylus salaris is a serious pest of wild pre-smolt Atlantic salmon (Salmo salar) in Norway. The closely related G. thymalli, originally described from grayling (Thymallus thymallus), is assumed harmless to both grayling and salmon. The 2 species are difficult to distinguish using traditional, morphometric methods or molecular approaches. The aim of this study was to explore whether there is a consistent pattern of morphometrical variation between G. salaris and G. thymalli and to analyse the morphometric variation in the context of 'diagnostic realism' (in natural populations). Specimens from the type-material for the 2 species are also included. In total, 27 point-to-point measurements from the opisthaptoral hard parts were used and analysed by digital image processing and uni- and multivariate morphometry. All populations most closely resembled its respective type material, as expected from host species, with the exception of G. thymalli from the Norwegian river Trysilelva. We, therefore, did not find clear support in the morphometrical variation among G. salaris and G. thymalli for an a priori species delineation based on host. The present study also indicates an urgent need for more detailed knowledge on the influence of environmental factors on the phenotype of gyrodactylid populations.

  1. Morphometric comparisons of Diaphorina citri (Hemiptera: Liviidae populations from Iran, USA and Pakistan

    Directory of Open Access Journals (Sweden)

    Mohammadreza Lashkari

    2015-05-01

    Full Text Available The Asian citrus psyllid (ACP, Diaphorina citri Kuwayama (Hemiptera: Liviidae, vector of citrus greening disease pathogen, Huanglongbing (HLB, is considered the most serious pest of citrus in the world. Prior molecular based studies have hypothesized a link between the D. citri in Iran and the USA (Florida. The purpose of this study was to collect morphometric data from D. citri populations from Iran (mtCOI haplotype-1, Florida (mtCOI haplotype-1, and Pakistan (mtCOI haplotype-6, to determine whether different mtCOI haplotypes have a relationship to a specific morphometric variation. 240 samples from 6 ACP populations (Iran—Jiroft, Chabahar; Florida—Ft. Pierce, Palm Beach Gardens, Port St. Lucie; and Pakistan—Punjab were collected for comparison. Measurements of 20 morphological characters were selected, measured and analysed using ANOVA and MANOVA. The results indicate differences among the 6 ACP populations (Wilks’ lambda = 0.0376, F = 7.29, P < 0.0001. The body length (BL, circumanal ring length (CL, antenna length (AL, forewing length (WL and Rs vein length of forewing (RL were the most important characters separating the populations. The cluster analysis showed that the Iran and Florida populations are distinct from each other but separate from the Pakistan population. Thus, three subgroups can be morphologically discriminated within D. citri species in this study, (1 Iran, (2 USA (Florida and (3 Pakistan population. Morphometric comparisons provided further resolution to the mtCOI haplotypes and distinguished the Florida and Iranian populations.

  2. MORPHOMETRIC EVIDENCE FOR NUTRITIONAL STRESS IN ENGLISH SOLE

    Science.gov (United States)

    We present an application of the powerful thin plate spline method of morphometric analysis to demonstrate its utility for detecting environmental stress in an estuarine flatfish. Juvenile English sole (Pleuronectes vetulus) were captured from Yaquina Bay, Oregon, photographed w...

  3. Loggerhead sea turtle oral cavity morphometrics and size class from 2001 to 2004 (NCEI Accession 0164321)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains standard external morphometrics and internal oral cavity morphometrics from wild and captive reared loggerhead sea turtles in size classes...

  4. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    Science.gov (United States)

    Akça, Kivanç; Chang, Ting-Ling; Tekdemir, Ibrahim; Fanuscu, Mete I

    2006-08-01

    The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and mandible of a human cadaver. Experiments were undertaken to quantify initial implant stability and bone micro-morphology. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to determine initial intraosseous implant stability. For quantification of relative bone volume and micro-architecture, sectioned implant-bone and bone core specimens of each implant placement site were consecutively scanned and trabecular bone was analyzed in a micro-computed tomography (micro-CT) unit. Experimental outcomes were evaluated for correlations among implant designs, initial intraosseous implant stability and bone micro-structural parameters. ITVs correlated higher with bone volume fraction (BV/TV) than ISQs, at 88.1% and 68.9% levels, respectively. Correlations between ITVs and micro-morphometric parameters were significant at the 95% confidence level (Pimplant designs used were not significant at the 95% confidence level (P>0.05). Bone micro-morphology has a prevailing effect over implant design on intraosseus initial implant stability, and ITV is more sensitive in terms of revealing biomechanical properties at the bone-implant interface in comparison with ISQ.

  5. Aneurysms of the anterior and posterior cerebral circulation: comparison of the morphometric features.

    Science.gov (United States)

    Tykocki, Tomasz; Kostkiewicz, Bogusław

    2014-09-01

    Intracranial aneurysms (IAs) located in the posterior circulation are considered to have higher annual bleed rates than those in the anterior circulation. The aim of the study was to compare the morphometric factors differentiating between IAs located in the anterior and posterior cerebral circulation. A total number of 254 IAs diagnosed between 2009 and 2012 were retrospectively analyzed. All patients qualified for diagnostic, three-dimensional rotational angiography. IAs were assigned to either the anterior or posterior cerebral circulation subsets for the analysis. Means were compared with a t-test. The univariate and stepwise logistic regression analyses were used to determine the predictors of morphometric differences between the groups. For the defined predictors, ROC (receiver-operating characteristic) curves and interactive dot diagrams were calculated with the cutoff values of the morphometric factors. The number of anterior cerebral circulation IAs was 179 (70.5 %); 141 (55.5 %) aneurysms were ruptured. Significant differences between anterior and posterior circulation IAs were found for: the parent artery size (5.08 ± 1.8 mm vs. 3.95 ± 1.5 mm; p 45) and aspect ratio (AR) (1.91 ± 0.8 vs. 2.75 ± 1.8; p = 0.02). Predicting factors differentiating anterior and posterior circulation IAs were: the AR (OR = 2.20; 95 % CI 1.80-270; Is 270 correct or should it be 2.70 and parent artery size (OR = 0.44; 95 % CI 0.38-0.54). The cutoff point in the ROC curve was 2.185 for the AR and 4.89 mm for parent artery size. Aspect ratio and parent artery size were found to be predictive morphometric factors in differentiating between anterior and posterior cerebral IAs.

  6. Morphometric analyses of the river basins in Goa

    Digital Repository Service at National Institute of Oceanography (India)

    Iyer, S.D.; Wagle, B.G.

    Morphometric analyses of seven river basins in Goa, India have been carried out. The linear and areal aspects of these basins are reported here. The plots of stream order versus stream numbers and stream orders versus mean stream lengths are found...

  7. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    Energy Technology Data Exchange (ETDEWEB)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Patrie, James T.; Xin, Wenjun [University of Virginia, Department of Public Health Sciences, Charlottesville, VA (United States); Wintermark, Max [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Centre Hospitalier Universitaire Vaudois, Department of Radiology, Lausanne (Switzerland)

    2014-03-15

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI{sub vol}), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI{sub vol} and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  8. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    International Nuclear Information System (INIS)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah; Patrie, James T.; Xin, Wenjun; Wintermark, Max

    2014-01-01

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI vol ), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI vol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  9. The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults—application to CT dosimetry

    International Nuclear Information System (INIS)

    Geyer, Amy M; O'Reilly, Shannon; Long, Daniel J; Bolch, Wesley E; Lee, Choonsik

    2014-01-01

    Substantial increases in pediatric and adult obesity in the US have prompted a major revision to the current UF/NCI (University of Florida/National Cancer Institute) family of hybrid computational phantoms to more accurately reflect current trends in larger body morphometry. A decision was made to construct the new library in a gridded fashion by height/weight without further reference to age-dependent weight/height percentiles as these become quickly outdated. At each height/weight combination, circumferential parameters were defined and used for phantom construction. All morphometric data for the new library were taken from the CDC NHANES survey data over the time period 1999–2006, the most recent reported survey period. A subset of the phantom library was then used in a CT organ dose sensitivity study to examine the degree to which body morphometry influences the magnitude of organ doses for patients that are underweight to morbidly obese in body size. Using primary and secondary morphometric parameters, grids containing 100 adult male height/weight bins, 93 adult female height/weight bins, 85 pediatric male height/weight bins and 73 pediatric female height/weight bins were constructed. These grids served as the blueprints for construction of a comprehensive library of patient-dependent phantoms containing 351 computational phantoms. At a given phantom standing height, normalized CT organ doses were shown to linearly decrease with increasing phantom BMI for pediatric males, while curvilinear decreases in organ dose were shown with increasing phantom BMI for adult females. These results suggest that one very useful application of the phantom library would be the construction of a pre-computed dose library for CT imaging as needed for patient dose-tracking. (paper)

  10. DNA-based and geometric morphometric analysis to validate species designation: a case study of the subterranean rodent Ctenomys bicolor.

    Science.gov (United States)

    Stolz, J F B; Gonçalves, G L; Leipnitz, L; Freitas, T R O

    2013-10-25

    The genus Ctenomys (Rodentia: Ctenomyidae) shows several taxonomic inconsistencies. In this study, we used an integrative approach including DNA sequences, karyotypes, and geometric morphometrics to evaluate the taxonomic validity of a nominal species, Ctenomys bicolor, which was described based on only one specimen in 1912 by Miranda Ribeiro, and since then neglected. We sampled near the type locality assigned to this species and collected 10 specimens. A total of 820 base pairs of the cytochrome b gene were sequenced and analyzed together with nine other species and four morphotypes obtained from GenBank. Bayesian analyses showed that C. bicolor is monophyletic and related to the Bolivian-Matogrossense group, a clade that originated about 3 mya. We compared the cranial shape through morphometric geometrics of C. bicolor, including the specimen originally sampled in 1912, with other species representative of the same phylogenetic group (C. boliviensis and C. steinbachi). C. bicolor shows unique skull traits that distinguish it from all other currently known taxa. Our findings confirm that the specimen collected by Miranda Ribeiro is a valid species, and improve the knowledge about Ctenomys in the Amazon region.

  11. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  12. Morphometric Study of Vocal Folds in Indian Cadavers

    Directory of Open Access Journals (Sweden)

    Rawal J.D.

    2015-06-01

    Full Text Available Introduction: -The larynx is an air passage and a sphincteric device used in respiration and phonation. The larynx, from inside outwards has a framework of mucosa surrounded by fibro-elastic membrane which in turn is surrounded by cartilages and then a layer of muscles. Vocal folds are intrinsic ligament of larynx covered by mucosal folds. Larynx generates sound through rhythmic opening and closing of the vocal folds. The perceived pitch of human voice mainly depends upon fundamental frequency of sound generated by larynx. Aim: - The aim of present study is to measure various dimensions of vocal folds in Indian cadavers. Material & Methods: - 50 larynx were obtained from embalmed cadavers, of which 10 larynx were of females. Vocal cords were dissected from the larynx and morphometric analysis was done. Results and Conclusions: - The average total length of the vocal folds was found to be 16.11 mm. ± 2.62 mm. in male and 14.10 mm. ± 1.54 mm. in female cadavers. The average width of the vocal folds was found to be 4.38 mm. ± 0.74 mm. in male and 3.60 mm. ± 0.64 mm. in female cadavers. The average total length of the membranous part of the vocal folds was found to be 11.90 mm. ± 1.86 mm. in male and 10.45 mm. ± 1.81 mm. in female cadavers. The average ratio of the length of the membranous and the cartilaginous parts of the vocal folds was calculated to be 3.10 ± 0.96in male and 2.85 ± 0.73in female cadavers.

  13. High prevalence of morphometric vertebral deformities in patients with inflammatory bowel disease.

    Science.gov (United States)

    Heijckmann, Anna Caroline; Huijberts, Maya S P; Schoon, Erik J; Geusens, Piet; de Vries, Jolanda; Menheere, Paul P C A; van der Veer, Eveline; Wolffenbuttel, Bruce H R; Stockbrugger, Reinhold W; Dumitrescu, Bianca; Nieuwenhuijzen Kruseman, Arie C

    2008-08-01

    Earlier studies have documented that the prevalence of decreased bone mineral density (BMD) is elevated in patients with inflammatory bowel disease. The objective of this study was to investigate the prevalence of vertebral deformities in inflammatory bowel disease patients and their relation with BMD and bone turnover. One hundred and nine patients with Crohn's disease (CD) and 72 with ulcerative colitis (UC) (age 44.5+/-14.2 years) were studied. BMD of the hip (by dual X-ray absorptiometry) was measured and a lateral single energy densitometry of the spine for assessment of vertebral deformities was performed. Serum markers of bone resorption (carboxy-terminal cross-linked telopeptide of type I collagen) and formation (procollagen type I amino-terminal propeptide) were measured, and determinants of prevalent vertebral deformities were assessed using logistic regression analysis. Vertebral deformities were found in 25% of both CD and UC patients. Comparing patients with and without vertebral deformities, no significant difference was found between Z-scores and T-scores of BMD, or levels of serum carboxy-terminal cross-linked telopeptide of type I collagen and serum procollagen type I amino-terminal propeptide. Using logistic regression analysis the only determinant of any morphometric vertebral deformity was sex. The presence of multiple vertebral deformities was associated with older age and glucocorticoid use. The prevalence of morphometric vertebral deformities is high in CD and UC. Male sex, but neither disease activity, bone turnover markers, clinical risk factors, nor BMD predicted their presence. The determinants for having more than one vertebral deformity were age and glucocorticoid use. This implies that in addition to screening for low BMD, morphometric assessment of vertebral deformities is warranted in CD and UC.

  14. Morphometric growth characteristics and body composition of bullfrog tadpoles in captivity

    Directory of Open Access Journals (Sweden)

    Cleber Menegasso Mansano

    2014-10-01

    Full Text Available Feed management needs to be improved in frog farming to reduce the indirect effects of inadequate feeding and, consequently, to increase growth rates and nutrient deposition, obtaining better quality animals. The objective of this study was to establish morphometric growth curves for bullfrog tadpoles (Lithobates catesbeianus and to determine nutrient deposition in the carcass. A total of 6,480 bullfrogs (Gosner stage 25 received an experimental diet (26.23% digestible protein and 32.68% crude protein and a commercial diet (37.92% crude protein ad libitum. A Gompertz model was used to describe the growth curve. Tadpoles fed the experimental diet presented higher final protein deposition. In addition, the sigmoidal curve was much more homogenous, indicating a more constant daily protein deposition rate. The Gompertz model provided an excellent fit of the data to describe the morphometric growth curve and carcass nutrient deposition of bullfrog tadpoles, showing that animals fed the experimental diet presented a better growth rate and nutrient deposition.

  15. Morphometric analysis of Dactylorhiza hatagirea (D. Don), a critically ...

    African Journals Online (AJOL)

    Admin

    2012-07-12

    Jul 12, 2012 ... interplay of climate, geographical history and evolutionary dynamics in ... morphometric analysis of living plant (Dressler and. Dodson, 1960) and to the .... Number of flowers. 25. UPPINT ..... Classification and phylogeny in the.

  16. Biometric and morphometric studies of Perna viridis and Perna indica along the southwest coast of India: a statistical approach

    Digital Repository Service at National Institute of Oceanography (India)

    Jayalakshmy, K.V.; Nair, M.; DileepKumar, R.; Vijayan, M.

    morphometric gradient groups (spat and adult), indicating the different phenotypic plasticity between them. The factor scores classified P. indica as a unimodal, positively skewed leptokurtic population and P. viridis as a unimodal, negatively skewed...

  17. The analysis of morphometric data on rocky mountain wolves and artic wolves using statistical method

    Science.gov (United States)

    Ammar Shafi, Muhammad; Saifullah Rusiman, Mohd; Hamzah, Nor Shamsidah Amir; Nor, Maria Elena; Ahmad, Noor’ani; Azia Hazida Mohamad Azmi, Nur; Latip, Muhammad Faez Ab; Hilmi Azman, Ahmad

    2018-04-01

    Morphometrics is a quantitative analysis depending on the shape and size of several specimens. Morphometric quantitative analyses are commonly used to analyse fossil record, shape and size of specimens and others. The aim of the study is to find the differences between rocky mountain wolves and arctic wolves based on gender. The sample utilised secondary data which included seven variables as independent variables and two dependent variables. Statistical modelling was used in the analysis such was the analysis of variance (ANOVA) and multivariate analysis of variance (MANOVA). The results showed there exist differentiating results between arctic wolves and rocky mountain wolves based on independent factors and gender.

  18. Morphometric magnetic resonance imaging and genetic testing in cerebellar abiotrophy in Arabian horses

    Science.gov (United States)

    2013-01-01

    Background Cerebellar abiotrophy (CA) is a rare but significant disease in Arabian horses caused by progressive death of the Purkinje cells resulting in cerebellar ataxia characterized by a typical head tremor, jerky head movements and lack of menace response. The specific role of magnetic resonance imaging (MRI) to support clinical diagnosis has been discussed. However, as yet MR imaging has only been described in one equine CA case. The role of MR morphometry in this regard is currently unknown. Due to the hereditary nature of the disease, genetic testing can support the diagnosis of CA. Therefore, the objective of this study was to perform MR morphometric analysis and genetic testing in four CA-affected Arabian horses and one German Riding Pony with purebred Arabian bloodlines in the third generation. Results CA was diagnosed pathohistologically in the five affected horses (2 months - 3 years) supported by clinical signs, necropsy, and genetic testing which confirmed the TOE1:g.2171G>A SNP genotype A/A in all CA-affected horses. On MR images morphometric analysis of the relative cerebellar size and relative cerebellar cerebrospinal fluid (CSF) space were compared to control images of 15 unaffected horses. It was demonstrated that in MR morphometric analyses, CA affected horses displayed a relatively smaller cerebellum compared to the entire brain mass than control animals (P = 0.0088). The relative cerebellar CSF space was larger in affected horses (P = 0.0017). Using a cut off value of 11.0% for relative cerebellar CSF space, the parameter differentiated between CA-affected horses and controls with a sensitivity of 100% and a specificity of 93.3%. Conclusions In conclusion, morphometric MRI and genetic analysis could be helpful to support the diagnosis of CA in vivo. PMID:23702154

  19. An insight into morphometric descriptors of cell shape that pertain to regenerative medicine.

    Science.gov (United States)

    Lobo, Joana; See, Eugene Yong-Shun; Biggs, Manus; Pandit, Abhay

    2016-07-01

    Cellular morphology has recently been indicated as a powerful indicator of cellular function. The analysis of cell shape has evolved from rudimentary forms of microscopic visual inspection to more advanced methodologies that utilize high-resolution microscopy coupled with sophisticated computer hardware and software for data analysis. Despite this progress, there is still a lack of standardization in quantification of morphometric parameters. In addition, uncertainty remains as to which methodologies and parameters of cell morphology will yield meaningful data, which methods should be utilized to categorize cell shape, and the extent of reliability of measurements and the interpretation of the resulting analysis. A large range of descriptors has been employed to objectively assess the cellular morphology in two-dimensional and three-dimensional domains. Intuitively, simple and applicable morphometric descriptors are preferable and standardized protocols for cell shape analysis can be achieved with the help of computerized tools. In this review, cellular morphology is discussed as a descriptor of cellular function and the current morphometric parameters that are used quantitatively in two- and three-dimensional environments are described. Furthermore, the current problems associated with these morphometric measurements are addressed. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  1. Leaf morphology, taxonomy and geometric morphometrics: a simplified protocol for beginners.

    Directory of Open Access Journals (Sweden)

    Vincenzo Viscosi

    Full Text Available Taxonomy relies greatly on morphology to discriminate groups. Computerized geometric morphometric methods for quantitative shape analysis measure, test and visualize differences in form in a highly effective, reproducible, accurate and statistically powerful way. Plant leaves are commonly used in taxonomic analyses and are particularly suitable to landmark based geometric morphometrics. However, botanists do not yet seem to have taken advantage of this set of methods in their studies as much as zoologists have done. Using free software and an example dataset from two geographical populations of sessile oak leaves, we describe in detailed but simple terms how to: a compute size and shape variables using Procrustes methods; b test measurement error and the main levels of variation (population and trees using a hierachical design; c estimate the accuracy of group discrimination; d repeat this estimate after controlling for the effect of size differences on shape (i.e., allometry. Measurement error was completely negligible; individual variation in leaf morphology was large and differences between trees were generally bigger than within trees; differences between the two geographic populations were small in both size and shape; despite a weak allometric trend, controlling for the effect of size on shape slighly increased discrimination accuracy. Procrustes based methods for the analysis of landmarks were highly efficient in measuring the hierarchical structure of differences in leaves and in revealing very small-scale variation. In taxonomy and many other fields of botany and biology, the application of geometric morphometrics contributes to increase scientific rigour in the description of important aspects of the phenotypic dimension of biodiversity. Easy to follow but detailed step by step example studies can promote a more extensive use of these numerical methods, as they provide an introduction to the discipline which, for many biologists, is

  2. Heritability of face shape in twins: a preliminary study using 3D stereophotogrammetry and geometric morphometrics

    Directory of Open Access Journals (Sweden)

    Seth M. Weinberg

    2013-11-01

    Full Text Available Introduction: Previous research suggests that aspects of facial surface morphology are heritable.  Traditionally, heritability studies have used a limited set of linear distances to quantify facial morphology and often employ statistical methods poorly designed to deal with biological shape.  In this preliminary report, we use a combination of 3D photogrammetry and landmark-based morphometrics to explore which aspects of face shape show the strongest evidence of heritability in a sample of twins. Methods: 3D surface images were obtained from 21 twin pairs (10 monozygotic, 11 same-sex dizygotic.  Thirteen 3D landmarks were collected from each facial surface and their coordinates subjected to geometric morphometric analysis.  This involved superimposing the individual landmark configurations and then subjecting the resulting shape coordinates to a principal components analysis.  The resulting PC scores were then used to calculate rough narrow-sense heritability estimates. Results: Three principal components displayed evidence of moderate to high heritability and were associated with variation in the breadth of orbital and nasal structures, upper lip height and projection, and the vertical and forward projection of the root of the nose due to variation in the position of nasion. Conclusions: Aspects of facial shape, primarily related to variation in length and breadth of central midfacial structures, were shown to demonstrate evidence of strong heritability. An improved understanding of which facial features are under strong genetic control is an important step in the identification of specific genes that underlie normal facial variation.

  3. Linear versus geometric morphometric approaches for the analysis of head shape dimorphism in lizards.

    Science.gov (United States)

    Fabre, Anne-Claire; Cornette, Raphäel; Huyghe, Katleen; Andrade, Denis V; Herrel, Anthony

    2014-09-01

    Differences between the sexes may arise because of differences in reproductive strategy, with females investing more in traits related to reproductive output and males investing more in traits related to resource holding capacity and territory defence. Sexual dimorphism is widespread in lizards and in many species males and females also differ in head shape. Males typically have bigger heads than females resulting in intersexual differences in bite force. Whereas most studies documenting differences in head dimensions between sexes use linear dimensions, the use of geometric morphometrics has been advocated as more appropriate to characterize such differences. This method may allow the characterization of local shape differences that may have functional consequences, and provides unbiased indicators of shape. Here, we explore whether the two approaches provide similar results in an analyses of head shape in Tupinambis merianae. The Argentine black and white tegu differs dramatically in body size, head size, and bite force between the sexes. However, whether the intersexual differences in bite force are simply the result of differences in head size or whether more subtle modifications (e.g., in muscle insertion areas) are involved remains currently unknown. Based on the crania and mandibles of 19 lizards with known bite force, we show intersexual differences in the shape of the cranium and mandible using both linear and geometric morphometric approaches. Although both types of analyses showed generally similar results for the mandible, this was not the case for the cranium. Geometric morphometric approaches provided better insights into the underlying functional relationships between the cranium and the jaw musculature, as illustrated by shape differences in muscle insertion areas not detected using linear morphometric data. © 2014 Wiley Periodicals, Inc.

  4. Hybridization within a Pilosella population: a morphometric analysis

    Czech Academy of Sciences Publication Activity Database

    Urfus, Tomáš; Krahulec, František; Krahulcová, Anna

    2014-01-01

    Roč. 49, č. 2 (2014), s. 223-238 ISSN 1211-9520 R&D Projects: GA ČR GA206/08/0890 Institutional research plan: CEZ:AV0Z60050516 Institutional support: RVO:67985939 Keywords : hybridization * introgression * multivariate morphometrics Subject RIV: EF - Botanics Impact factor: 1.778, year: 2014

  5. ANALISIS KARAKTER TRUSS MORPHOMETRICS PADA IKAN KEMPRIT (Ilisha megaloptera FAMILIA PRISTIGASTERIDAE

    Directory of Open Access Journals (Sweden)

    Tri Wijayanti

    2017-06-01

    Full Text Available The fish auction site at Ocean Fishing Port of Cilacap is one of the major fish landings sites in Indonesia. Fishes landed in this port mainly of large pelagic fish, bycatch, crustaceans including kemprit fish (Ilisha megaloptera Swainson,1839. Kemprit fish is a member of the family Pristigasteridae, which has an elongated body shape-sprawl. Fishers use this fish as the main ingredient to produce fish crackers and dried salted fish. Overfishing is the greatest threat to kemprit fish, and without conservation efforts the future population is uncertain. Fish farming is one right answer in kemprit fish conservation. However, information on this fish biology is insufficient. One of the biological aspects is sexual dimorphism, the morphological properties that can be used to distinguish between male and female fish. Truss morphometrics can measure the morphological traits differences of male and female. This technique in which the measurement of the distance Truss morphometrics in certain parts, by the benchmark points (dots Truss morphometrics, then compared with standard size. The result of the preliminary survey indicated that kemprit fish did not show sexual dimorphism, therefore truss morphometric technique applies to distinguish sexes of this fish. This research was a survey, and purposive sampling techniques were used to collect data. Data were then analyzed using the “t” test. The results showed that distinct truss distance between male and female fish was the distance between the anterior base of the dorsal fin to the anterior base of the ventral fins and the distance between the posterior base of the dorsal fin to the anterior base of the anal fin.

  6. PET/CT and contrast enhanced CT in single vs. two separate sessions: a cost analysis study.

    Science.gov (United States)

    Picchio, M; Mansueto, M; Crivellaro, C; Guerra, L; Marcelli, S; Arosio, M; Sironi, S; Gianolli, L; Grimaldi, A; Messa, C

    2012-06-01

    Aim of the study was to quantify the economic impact of PET/CT and contrast enhanced (c.e.) CT performed in a single session examination vs. stand-alone modalities in oncological patients. One-hundred-forty-five cancer patients referred to both PET/CT and c.e. CT, to either stage (N.=46) or re-stage (N.=99) the disease, were included. Seventy-two/145 performed both studies in a single session (innovative method) and 73/145 in two different sessions (traditional method). The cost-minimization analysis was performed by evaluating: 1) institutional costs, data obtained by hospital accountability (staff, medical materials, equipment maintenance and depreciation, departments utilities); 2) patients costs, data obtained by a specific survey provided to patients (travel, food, accommodation costs, productivity loss). Economic data analysis showed that the costs for innovative method was lower than those of traditional method, both for Institution (106 € less per test) and for patient (21 € less per patient). The loss of productivity for patient and caregivers resulted lower for the innovative method than the traditional method (3 work-hour less per person). PET/CT and c.e. CT performed in a single session is more cost-effective than stand-alone modalities, by reducing both Institutional and patients costs. These advantages are mainly due to lower Institutional cost (single procedure) and to lower cost related to travel and housing.

  7. The anterior cruciate ligament: a study on its bony and soft tissue anatomy using novel 3D CT technology.

    Science.gov (United States)

    Tampere, Thomas; Van Hoof, Tom; Cromheecke, Michiel; Van der Bracht, Hans; Chahla, Jorge; Verdonk, Peter; Victor, Jan

    2017-01-01

    The purpose of this study is twofold: first, to visualize both the tibial and femoral bony insertion surfaces and second, to describe the anterior cruciate ligament (ACL) geometrically, using novel 3D CT imaging. In addition, new concepts of best-fit cylinder and central axis are introduced and evaluated. Eight unpaired knees of embalmed cadavers were used in this study. Following the dissection process, the ACL was injected with a contrast medium for CT imaging. The obtained CT images in extension, 45°, 90° and full flexion were segmented and rendered in 3D allowing morphological and morphometric analysis of the ACL. Anatomical footprint centres, femoral and tibial footprint surface area, best-fit ACL-cylinder intersection area, best-fit ACL-cylinder/footprint coverage ratio, best-fit ACL-cylinder central axis projections at the tibial and femoral footprint in the four positions were used to describe the anatomy of the ACL, based on the Bernard, Hertel and Amis grid. Based on these parameters, with the best-fit cylinder representing the bulk of the ACL, a changing fibre-recruitment pattern was seen with a moving position of the central axis from posterior to anterior on the femoral and tibial footprint, going from extension to flexion. Furthermore, the numerical data show an increase in tibial footprint coverage by the best-fit cylinder through the ACL when the knee is progressively flexed, whereas an inverse relationship was seen on the femoral side. This study is the first to describe the detailed anatomy of the human ACL with respect to its course and footprints using a 3D approach. It confirms the large difference and inter-patient variability between the tibial and femoral footprint area with the former being significantly smaller. The best-fit cylinder concept illustrates the recruitment pattern of the native ACL where in extension the postero-lateral fibres are recruited and in flexion rather the antero-medial bundle, which can be valuable information in

  8. The Oncogenic Risks of Diagnostic CT Scam Studies in Children

    International Nuclear Information System (INIS)

    Brent, R.

    2004-01-01

    Brenner et al (2001) reported that estimates of the exposure to children from CT scans indicates that the exposures are both higher than from conventional radiographic studies and higher than is necessary to obtain quality examinations. utilizing the oncogenic risk data from the RERF study in Japan, Brenner et al estimated that the oncogenic risk in this population of CT exposed children exposed each year would result in an additional 500 cases of cancer. This risk estimate is supported by the RERF epidemiological data obtained from the populations exposed in Hiroshima and Nagasaki. the increased risks associated with the increased exposure from CT scans have raised concern and stimulated discussion. Although there is little doubt about the benefits of CT scans in improving the health care of children, there is concern about the estimated oncogenic risk, especially since the frequency of CT studies has been increasing. Applying the oncogenic risks of ionizing radiation from the RERF data may not be appropriate for all types of radiation exposure for accurately predicting the incidence of cancer in exposed children because of the impact of 1) partial versus whole-body irradiation, and 2) the protraction of the exposure. Other population of children who have been exposed to radiation and whose incidence of cancer has been studied will be presented and those studies indicate that the risk of cancer is much lower or not increased at all with exposures in the diagnostic range. finally, the dramatic impact of the use of CT scans in clinical pediatric practice saves lives and improves diagnostic accuracy. Therefore, it is crucial that a scholarly evaluation of the risks and benefits should be initiated. The radiology community and the manufacturers have already initiated programs to decrease the exposure significantly. But it is essential that well-planned, retrospective and prospective epidemiology studies should be initiated to study the oncogenic risks. If you want to

  9. [Some morphometric parameters of nucleoli and nuclei in invasive ductal breast carcinomas in women].

    Science.gov (United States)

    Karpinska-Kaczmarczyk, Katarzyna

    2009-01-01

    The purpose of this study was to correlate seven morphometric parameters of nucleoli and nuclei of invasive ductal cancer cells with some clinico-pathological factors such as age, tumor size, axillary lymph node status, MIB-1 proliferation index, and estrogen receptor expression in tumor cells. Methyl green-pyronin Y (MG-PY) was used for simultaneous staining of nuclei and nucleoli in histological sections of 150 invasive ductal breast carcinomas. Next, morphometric parameters of nucleoli and nuclei of tumor cells were measured with computerized image analysis. Nuclear area and number of nucleoli in breast tumor cells were greater in younger axillary node-negative patients. The number of nucleoli and nucleolar shape polymorphism were reduced in tumors measuring 20 mm or less or with lower histological grade. Nuclear area, nucleolar number, and nucleolar polymorphism in carcinomas with low proliferation index and estrogen receptor expression were smaller than in carcinomas with high proliferation index and no estrogen receptor expression. Nucleolar area in primary tumors without axillary node involvement was greater than in tumors with more than three axillary nodes positive. MG-PY selectively and simultaneously stains nucleoli and nuclei of tumor cells enabling standardized and reproducible examination of these structures with computerized image analysis. Univariate statistical analysis disclosed that some morphometric parameters of nucleoli and nuclei of tumor cells correlated with several established clinico-pathological prognostic factors. Therefore, the prognostic significance of these parameters should be studied in a larger group of patients with invasive ductal breast carcinomas.

  10. Morphometric analysis of sub-watershed in parts of Western Ghats, South India using ASTER DEM

    Directory of Open Access Journals (Sweden)

    Evangelin Ramani Sujatha

    2015-05-01

    Full Text Available Morphometric analysis is a key to understand the hydrological process and hence is a prerequisite for the assessment of hydrological characteristics of surface water basin. Morphometric analysis to determine the drainage characteristics of Palar sub-watershed, a part of Shanmukha watershed in the Amaravati sub-catchment is done using Advanced Space-borne Thermal Emission and Reflection Global Digital Elevation Model (ASTER GDEM data, and is supplemented with topographical maps in geographical information systems platform. This study uses ASTER GDEM data to extract morphometric features of a mountain stream at micro-watershed level. The sub-watershed is divided into six micro-watersheds. The sub-watershed includes a sixth-order stream. Lower stream orders, in particular first-order streams, dominate the sub-watershed. Development of stream segments is controlled by slope and local relief. Drainage pattern of the sub-watershed and micro-watersheds is dendritic in general. The mean bifurcation ratio of the sub-watershed is 3.69 but its variation between the various stream orders suggests structural control in the development of stream network. The shape factors reveal the elongation of the sub-watershed and micro-watersheds.The relief ratio reveals the high discharge capability of the sub-watershed and meagre groundwater potential. This study is a useful tool for planning strategies in control of soil erosion and soil conservation.

  11. Morphometric Characteristics and Length-Weight Relationship of Russian Sturgeon Juveniles Fed with Different Ratio

    Directory of Open Access Journals (Sweden)

    Raluca Cristina ANDREI(GURIENCU

    2017-11-01

    Full Text Available The aim of this paper was to analyze some morphometric characteristics and the correlation between them for Russian sturgeon juveniles (Acipenser gueldenstaedtii reared in a recirculating aquaculture system fed at different fed with different ratio: 1% body weight (BW, 1.5% BW, 2% BW and ad libitum feeding (which was around 2.8% BW.Fish, with an average body mass around 248.194 ± 1.59 g. Following biometric measurements were made for each fish, including weight (W, total length (TL, standard length (SL, fork length (FL, maximum body depth (last depth of caudal peduncle, H; preanal distance (AD, predorsal distance (PD, length of head (C, preorbital distance (PO, length of pectoral fin (LPF, interorbital distance (ID, maximum width of head (MH, width of mouth (WM, width of the head at the level of the mouth (WHM. The obtained results showed significant differences between all morphometric measurements (p<0.05 for all the experimental variants, emphasizing that in the ad libitum feeding all morphometric measurements were significantly higher than in the other experimental variants. In order to highlight more eloquent these differences, were developed some linear regressions between the morphometric measurements and significant positive correlation (p<0.05 between dependent and independent variables were found.

  12. Assessment Of Morphometric Characteristics Of Karwadi-Nandapur Micro Watershed Using Remote Sensing And Geographical Information System

    Directory of Open Access Journals (Sweden)

    N.P. Patil

    2015-04-01

    Full Text Available Abstract The study area is Karwadi-Nandapur watershed is a micro watershed which falls in the Kayadhu river watershed in Marathwada region of Maharashtra. Using the remotely sensed images of the Indian Remote Sensing Satellite P6 IRS P6 Linear Imaging Self Scanner IIILISS III images captured in October 2010 and November 2011 having resolution of 23.5m X 23.5m and images from Google Earth Pro of study area were used and cartosat satellites. Map of India with scale 11500000 and soil maps of India were used for the experimental study. The thematic maps like drainage map land use and land cover map soil maps and contour map were prepared adopting the PCI Geomatica10.0 software. The geographical information systems GIS analysis was made for the said themes using the Arc GIS ArcMap10.0. The Karwadi- Nandapur watershed was found to be the third order basin. The present study aims to assess the morphometric characteristics of the watershed basin and it has been assessed by applying GIS techniques. Strahlers method has been employed to assess the fluvial characteristics of the study watershed. Each morphometric characteristic is considered as a single parameter and knowledge based weight age has been assigned by considering its role in soil erosion. The morphometric properties determined for this watershed as a whole and for each watershed will be useful for the efficient planning of water harvesting and groundwater projects on watershed basis.

  13. EVOLUTION OF MORPHOMETRIC MEASURES IN THE MANGALARGA MARCHADOR BREED

    Directory of Open Access Journals (Sweden)

    JULIANO MARTINS SANTIAGO

    2016-01-01

    Full Text Available The Mangalarga Marchador breed accounts for the largest horse herd in Brazil and has been experiencing national and international expansion. Nevertheless, there is little scientific production on the evolution of this breed and there are no studies on the morphometric transformations that took place during its formation. In this context, the present study aimed to assess the evolution in morphometric measures of the Mangalarga Marchador breed between 1970 and 2010. The research used information archived at the Brazilian Association of Mangalarga Marchador Breeders from 23,148 males and 92,980 females in a completely randomized experimental design. The six treatments consisted of the animals measured between 1970 and 1979, 1980 and 1989, 1990 and 1994, 1995 and 1999, 2000 and 2004, and 2005 and 2010, respectively. The measures assessed were: height at withers and croup, length of the head, neck, back, croup, shoulder, and body, width of the head and croup, thoracic circumference, and cannon circumference Over the period analyzed, males and females experienced a reduction in thoracic circumference, in the lengths of the head, back, croup, and shoulder, and in the widths of the head and croup. In the males, neck length and cannon circumference also decreased, while body length increased in females. Over time, breed selection led to smaller head, higher stature, and shorter trunk length. However, important measures for the breed’s functionality, such as shoulder length and thoracic circumference, decreased.

  14. morphometric features of a low-elevation urban catchment

    African Journals Online (AJOL)

    PROF EKWUEME

    River basin morphometric is a geomorphological tool that applies to physical ... Harcourt region's drainage as it pertains to flooding described the area as ... floods in several sub-basins of a river that posed risks to ... Bight of Bonny, off the Gulf of Guinea into the Atlantic ..... the extreme; because such forest will be thick and.

  15. Morphometric and molecular differentiation between quetzal subspecies of Pharomachrus mocinno (Trogoniformes: Trogonidae).

    Science.gov (United States)

    Solórzano, Sofía; Oyama, Ken

    2010-03-01

    The resplendent Quetzal (Pharomachrus mocinno) is an endemic Mesoamerican bird species of conservation concern. Within this species, the subspecies P. m. costaricensis and P. m. mocinno, have been recognized by apparent morphometric differences; however, presently there is no sufficient data for confirmation. We analyzed eight morphometric attributes of the body from 41 quetzals: body length, tarsus and cord wing, as well as the length, wide and depth of the bill, body weight; and in the case of the males, the length of the long upper-tail cover feathers. We used multivariate analyses to discriminate morphometric differences between subspecies and contrasted each morphometric attribute between and within subspecies with paired non-parametric Wilcoxon test. In order to review the intraspecific taxonomic status of this bird, we added phylogenetic analysis, and genetic divergence and differentiation based on nucleotide variations in four sequences of mtDNA. The nucleotide variation was estimated in control region, subunit NDH6, and tRNAGlu and tRNAPhe in 26 quetzals from eight localities distributed in five countries. We estimated the genetic divergence and differentiation between subspecies according to a mutation-drift equilibrium model. We obtained the best mutation nucleotide model following the procedure implemented in model test program. We constructed the phylogenetic relationships between subspecies by maximum parsimony and maximum likelihood using PAUP, as well as with Bayesian statistics. The multivariate analyses showed two different morphometric groups, and individuals clustered according to the subspecies that they belong. The paired comparisons between subspecies showed strong differences in most of the attributes analyzed. Along the four mtDNA sequences, we identified 32 nucleotide positions that have a particular nucleotide according to the quetzals subspecies. The genetic divergence and the differentiation was strong and markedly showed two groups

  16. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-12-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: (1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. (2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. (3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis.

  17. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: 1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. 2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. 3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis. (author)

  18. Morphometric variation in the Tunisian green frog, Rana saharica ...

    African Journals Online (AJOL)

    Rana saharica is the most widely distributed anuran in Tunisia. We examined morphological variation in 124 specimens as a function of their geographical origin, using univariate and multivariate statistics with traditional morphometrics. Our results supported the existence of three morphotypes of this species, correctly ...

  19. A morphometric analysis of the genus Ficus Linn. (moraceae ...

    African Journals Online (AJOL)

    Foliar parameters of Ficus in Nigeria were subjected to quantitative analysis. The morphometric analysis is based on ten quantitative parameters of the leaves of species. Principal compound analysis produced six groups whose characters are described. Highly significant positive correlation exists between leaf length and ...

  20. Nerve growth factor induced changes in the Golgi apparatus of PC-12 rat pheochromocytoma cells as studied by ligand endocytosis, cytochemical and morphometric methods.

    Science.gov (United States)

    Hickey, W F; Stieber, A; Hogue-Angeletti, R; Gonatas, J; GOnatas, N K

    1983-10-01

    Cells of the PC-12 rat pheochromocytoma cell line respond to nerve growth factor (NGF) by sprouting neurites and biochemically differentiating into sympathetic ganglion-like cells. NGF-stimulated ('differentiated') and unstimulated ('undifferentiated') cells were studied by cytochemical techniques for the localization of the enzymes acid phosphatase (ACPase) and thiamine pyrophosphatase (TPPase), and by a morphometric analysis of the distribution of endocytosed wheat-germ agglutinin labelled with horseradish peroxidase (WGA-HRP). Both cytochemical stains showed the enzymes to be distributed in lysosomes and certain cisternae of the Golgi apparatus in both NGF stimulated and unstimulated cells. ACPase was not confined to GERL (Golgi-endoplasmic reticulum-lysosome) as in certain other cells. The morphometric studies demonstrated that the reaction product of the internalized WGA-HRP occupied 4.7% of the cytoplasmic area in unstimulated cells and 4.5% in NGF-stimulated ones. Despite this similarity, the distribution of the WGA-HRP among the studied intracellular compartments in these two cell groups varied. In the NGF-stimulated cells 3.3% of the WGA-HRP reaction product was found in the innermost Golgi cisterna(e) while in unstimulated cells only 0.3% was seen in this compartment. Similarly, 4.3% of the WGA-HRP stain was found in small vesicles at the 'trans' aspect of the Golgi apparatus in stimulated cells, when only 0.3% of the stain occupied this compartment in 'undifferentiated' cells. The morphometric analysis also revealed that when the PC-12 cells were stimulated with NGF, the Golgi apparatus increased in area by approximately 70%. These findings are consistent with the hypothesis that NGF induced differentiation of PC-12 cells is coupled with enhanced endocytosis of WGA and probably of its 'receptor' to the innermost Golgi cisterna(e) and the closely associated vesicles.

  1. THE PROBIOTIC Enterococcus faecium MODIFIES THE INTESTINAL MORPHOMETRIC PARAMETERS IN WEANING PIGLETS

    Directory of Open Access Journals (Sweden)

    Johana Andrea Ciro Galeano

    2016-01-01

    Full Text Available Global trends for animal production have seen a decrease in the use of antimicrobial compounds in feed, generating the need to implement new nutritional strategies that stimulate growth and promote intestinal health. This study aimed to determine whether the addition of E. faecium in drinking water improves intestinal morphometric parameters in post- weaning pigs compared with the probiotics strains L. acidophilus and L. casei on days 1 (21 days of age, 15 and 30 postweaning. The small intestine was completely removed to evaluate the morphometric parameters (length and width of villi and crypts in the different intestinal segments (duodenum, jejunum, and ileum. They were fed for 30 days with two diets: commercial diet with or without antibiotics. The different probiotics, L. acidophillus, L. casei and E. faecium, were administered in the drinking water of the animals that consumed the commercial diet without antibiotics. A randomized block design in split-plot arrangement was used. There was a significant increase (P<0.01 in the width and length of villi, and a decrease (P<0.01 in the values obtained for the width and depth of crypts in the animals that consumed E .faecium, as compared to those that consumed the diet with addition of antibiotics. The use of probiotics, especially E. faecium, is a nutritional treatment strategy when antimicrobial compound are used, improving the intestinal morphometric parameters and, at the same time, the digestive and productive parameters of the animals. Work is in progress to investigate the effects of probiotic supplementation on the mofication of gut microbiota of post-weaning piglets

  2. Penentuan Jenis Kelamin Benih Ikan Betutu (Oxyeleotris marmorata Blkr. dengan Teknik Truss Morphometrics

    Directory of Open Access Journals (Sweden)

    Atang Atang

    2015-01-01

    Full Text Available A study on The Gender Determination Of Betutu Germ (Oxyeleotris marmorata Blkr. by Truss Morphometrics used survey method with Simple Random Sampling design, Betutu’s germ as sample were taken from Penjalin reservoir,  Brebes. The 26 distance of 13 pile points were based or Truss Morphometrics it were recorded as variables. The result of this research indicated that the size of Betutu’s A2 (origin anterior tip of snout at upper jaw – most posterior aspect of neurocranium, A4 (origin posterior point maxillary – origin of pelvic fin, B5 (origin of pelvic fin – origin of dorsal fin, B6 (origin of pelvic fin – origin of anal fin, D1 (insertion of anal fin – origin of lower caudal fin and D3 (insertion of dorsal II fin – origin of lower caudal fin can differentiate the gender of Betutu’s germ.

  3. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  4. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  5. Reducing dose in paediatric CT: a preliminary study of radiographers' knowledge

    International Nuclear Information System (INIS)

    Heagney, J.; Lewis, S.; Chaffey, C.; Howlett, G.; Moran, A.; McLean, D.

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs. Copyright (2003) Australian Institute of Radiography

  6. Reducing dose in paediatric CT: a preliminary study of radiographers' Knowledge

    International Nuclear Information System (INIS)

    Heagney, Jillian; Lewis, Sarah; Chaffey, Clare; Howlett, Genevieve; Moran, Alexander; McLean, Donald

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs Copyright (2003) Australian Institute of Radiography

  7. CT quantitative diagnosis in fatty liver: a clinical study

    International Nuclear Information System (INIS)

    He Wen; Qian Linxue; Zhao Jixue; Ma Daqing; Feng Jie; Hu Zhihai

    2001-01-01

    Objective: To establish the CT criteria of quantitative diagnosis for liver steatosis by means of studying the CT features of fatty liver cases proven histologically. Methods: Twenty-eight cases of fatty liver were underwent non-enhanced CT scan, and the attenuation of liver parenchyma was measured. To differentiate the degree of fatty liver, the mean CT value and the relative density of hepatic vessels were observed. The quantitative diagnosis was made according to the CT number threshold and the criteria of relative density of hepatic vessels, respectively. Results: Among the 28 cases, there were 17 cases of mild steatosis with mean CT number of 46 HU (32-65 HU), 7 cases of middle degree fatty liver with mean CT number of 28 HU (15-38 HU), and 4 cases of sever fatty liver with mean CT number of 0.2 HU (-7-11 HU). For the relative density of hepatic vessels, 16 of the 17 cases of mild fatty liver had a appearance of hepatic vessels immersion and 1 mild case had reverse hepatic vessels display, 6 of 7 middle degree cases had reverse hepatic vessels display with 1 case having the appearance of hepatic vessels immersion, and all the 4 case of sever steatosis had the appearance of reverse hepatic vessels display with sharp contrast between vessels and the liver parenchyma. The accuracy of quantitative diagnosis was 65.9% and 93.1% by means of criteria of CT number threshold and relative density of hepatic vessels, respectively (x 2 = 7.153, P < 0.01). Conclusion: The criteria of relative density of hepatic vessels is more reliable than that of CT number threshold in quantitative diagnosis of fatty liver

  8. Morphometric aspects of the foramen magnum and the orbit in Brazilian dry skulls

    Directory of Open Access Journals (Sweden)

    Lucas A. S. Pires

    2016-04-01

    Full Text Available Morphometric analysis of crania structures are of great significance to anatomists, forensic doctors, anthropologists, and surgeons. We performed a morphometric study regarding the foramen magnum and the bony orbit on the right side of the cranium in 77 skulls with the purpose of identifying a correlation between these measures, as they are often employed alone to identify the genre and race of a skeleton with no other remains, since the cranium is a structure that can resist fire, explosions, and mutilations. The foramen magnum receives special attention, as it is located in a region together with many strong muscles and ligaments. The measures were taken with a sliding digital caliper. Our results showed that the foramen magnum had a mean anteroposterior diameter of 34.23±2.54 mm, and the mean transverse diameter was 28.62±2.83 mm. The most common shape for the foramen magnum was oval. The mean right orbital height was 32.89±2.45 mm, and the mean right orbital breadth was 37.15±2.68 mm. There was a weak to moderate correlation between these measures. Furthermore, the foramen magnum and the orbit are regions of surgical and clinical significance, thus requiring knowledge regarding the morphometric aspects of such areas, since they can often suffer morphological changes due to a number of diseases and they undergo surgical procedures in order to treat these conditions.

  9. Radioprotective effect of vitamin E in parotid glands: a morphometric analysis in rats

    International Nuclear Information System (INIS)

    Gomes, Carolina Cintra; Boscolo, Frab Norberto; Almeida, Solange Maria de; Ramos-Perez, Flavia Maria de Moraes; Perez, Danyel Elias da Cruz; Novaes, Pedro Duarte

    2013-01-01

    The aim of this study was to evaluate the radioprotective effect of vitamin E on rat parotid glands by morphometric analysis. Sixty male rats were divided into 5 groups (n=6): control, in which animals received olive oil solution; olive oil/irradiated, in which animals received olive oil and were irradiated with a dose of 15 Gy of gamma radiation; irradiated, in which animals were irradiated with a dose of 15 Gy gamma radiation; vitamin E, which received α-tocopherol acetate solution; vitamin E/irradiated, which received α-tocopherol acetate solution before irradiation with a dose of 15 Gy gamma rays. Half of the animals were euthanized at 8 h, and the remaining at 30 days after irradiation. Both parotid glands were surgically removed and morphometric analysis of acinar cells was performed. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Morphometric analysis showed a significant reduction in the number of parotid acinar cells at 30 days in olive oil/irradiated and irradiated groups. In groups evaluated over time a significant reduction was shown at 30 days in olive oil/irradiated and irradiated groups, indicating that ionizing radiation caused tissue damage. The vitamin E/irradiated group presented more acinar cells than the irradiated group, but no statistically significant difference was observed (p>0.05). In conclusion, vitamin E seems to have failed as a radioprotective agent on acinar cells in rat parotid glands. (author)

  10. Radioprotective effect of vitamin E in parotid glands: a morphometric analysis in rats

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Carolina Cintra; Boscolo, Frab Norberto; Almeida, Solange Maria de [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Dept. de Diagnostico Oral; Ramos-Perez, Flavia Maria de Moraes; Perez, Danyel Elias da Cruz, E-mail: flavia.ramosperez@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Clinica e Odontologia Preventiva; Novaes, Pedro Duarte [Universidade Estadual de Campinas (UNICAMP), Piracicaba, SP (Brazil). Escola de Odontologia. Dept. de Morfologia

    2013-11-01

    The aim of this study was to evaluate the radioprotective effect of vitamin E on rat parotid glands by morphometric analysis. Sixty male rats were divided into 5 groups (n=6): control, in which animals received olive oil solution; olive oil/irradiated, in which animals received olive oil and were irradiated with a dose of 15 Gy of gamma radiation; irradiated, in which animals were irradiated with a dose of 15 Gy gamma radiation; vitamin E, which received {alpha}-tocopherol acetate solution; vitamin E/irradiated, which received {alpha}-tocopherol acetate solution before irradiation with a dose of 15 Gy gamma rays. Half of the animals were euthanized at 8 h, and the remaining at 30 days after irradiation. Both parotid glands were surgically removed and morphometric analysis of acinar cells was performed. Data were subjected to two-way ANOVA and Tukey's test ({alpha}=0.05). Morphometric analysis showed a significant reduction in the number of parotid acinar cells at 30 days in olive oil/irradiated and irradiated groups. In groups evaluated over time a significant reduction was shown at 30 days in olive oil/irradiated and irradiated groups, indicating that ionizing radiation caused tissue damage. The vitamin E/irradiated group presented more acinar cells than the irradiated group, but no statistically significant difference was observed (p>0.05). In conclusion, vitamin E seems to have failed as a radioprotective agent on acinar cells in rat parotid glands. (author)

  11. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    International Nuclear Information System (INIS)

    Lewis, Maria; Honey, Ian; Goh, Vicky; Beggs, Shaun; Bridges, Andrew; Wayte, Sarah; Clewer, Philip; Davis, Anne; Foy, Trevelyan; Fuller, Karen; George, Jennifer; Higginson, Antony; Iball, Gareth; Mutch, Steve; Neil, Shellagh; Sutton, David; Rivett, Cat; Slater, Andrew; Weir, Nick

    2014-01-01

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI vol , DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml -1 and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  12. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Maria; Honey, Ian [Trust, Medical Physics Department, Guy' s and St. Thomas' NHS Foundation, London (United Kingdom); Goh, Vicky [King' s College London, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Beggs, Shaun [Bradford Teaching Hospitals NHS Foundation Trust, Radiation Physics Services, Bradford (United Kingdom); Bridges, Andrew; Wayte, Sarah [Radiology Physics University Hospitals Coventry and Warwickshire NHS Trust, Coventry (United Kingdom); Clewer, Philip [Medical Physics Department, University Hospital Southampton NHS Foundation Trust, Southampton (United Kingdom); Davis, Anne [Portsmouth Hospitals NHS Trust, Medical Physics Department, Portsmouth (United Kingdom); Foy, Trevelyan [Royal Cornwall Hospital NHS Trust, Medical Physics Department, Truro (United Kingdom); Fuller, Karen [Sheffield Teaching Hospitals NHS Foundation Trust, Medical Physics Department, Sheffield (United Kingdom); George, Jennifer [University Hospital of North Staffordshire NHS Trust, Medical Physics Department, Stoke-on-Trent (United Kingdom); Higginson, Antony [Portsmouth Hospitals NHS Trust, Department of Radiology, Portsmouth (United Kingdom); Iball, Gareth [Leeds Teaching Hospitals NHS Trust, Department of Medical Physics and Engineering, Leeds (United Kingdom); Mutch, Steve [Oxford University Hospitals NHS Trust, Radiation Physics and Protection Department, Oxford (United Kingdom); Neil, Shellagh; Sutton, David [NHS Tayside, Medical Physics Department, Dundee, Scotland (United Kingdom); Rivett, Cat [Plymouth Hospitals NHS Trust, Clinical and Radiation Physics, Plymouth (United Kingdom); Slater, Andrew [Oxford University Hospitals NHS Trust, Department of Radiology, Oxford (United Kingdom); Weir, Nick [Queen' s Medical Research Institute, Clinical Research Imaging Centre, Edinburgh, Scotland (United Kingdom); Collaboration: on behalf of the PROSPeCT Investigators

    2014-09-15

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI{sub vol}, DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml{sup -1} and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  13. 13 Morphometric Analysis of Ogunpa and Ogbere Drainage Basins ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    significance of these landscape parameters was ... reported that the geomorphic characteristics of a drainage basins play ... form and process of drainage basins that may ... tropical rain forest of Nigeria occupying an area of .... morphometric parameters such as relief, shape ... on floodplains can be pulled down while areas.

  14. Relative growth, sexual dimorphism and morphometric maturity of Trichodactylus fluviatilis (Decapoda: Brachyura: Trichodactylidae from Santa Terezinha, Bahia, Brazil

    Directory of Open Access Journals (Sweden)

    Tiago Rozário da Silva

    2014-02-01

    Full Text Available Freshwater crabs are important elements in the aquatic biota of brooks, rivers, lakes and ponds, from both ecological and the socio-economic aspects. Trichodactylidae comprises 51 endemic species from the Neotropical region. Among all the species of this family, Trichodactylus fluviatilis Latreille, 1828 has the widest geographic distribution throughout Brazil. Despite that, there are few published contributions on the biology of this species. The present study investigated the following aspects of T. fluviatilis: relative growth, mean size at onset of morphometric maturity, sexual dimorphism, laterality and heterochely. Specimens were collected monthly from September 2010 through August 2011, from the Velha Eugênia Brook, municipality of Santa Teresinha, State of Bahia. Carapace width (CW, carapace length (CL, major cheliped length (MaCL and minor cheliped length (MiCL, major cheliped height (MaCH and minor cheliped height (MiCH, and width of the fifth abdominal segment (5AB were measured to evaluate the presence of sexual dimorphism; the major difference between the sexes was in the CW vs. 5AB ratio. Heterochely was observed in males and females,with the right cheliped larger than the left in 89% of males and 81% of females. Crab size at the onset of morphometric maturity (= puberty molt was estimated based on the ratio between CL, cheliped dimensions, 5AB and CW (independent variable. Females were larger than males when they reached morphometric maturity in all studied relations. We recommend the use of chelipeds and abdominal width relationships to estimate the size at the morphometric maturity in males and females, respectively.

  15. Determination of a novel size proxy in comparative morphometrics

    Directory of Open Access Journals (Sweden)

    Andrew Gallagher

    2015-09-01

    Full Text Available Absolute size is a critical determinant of organismal biology, yet there exists no real consensus as to what particular metric of ‘size’ is empirically valid in assessments of extinct mammalian taxa. The methodological approach of JE Mosimann has found extensive favour in ‘size correction’ in comparative morphometrics, but not ‘size prediction’ in palaeontology and palaeobiology. Analyses of five distinct mammalian data sets confirm that a novel size variate (GMSize derived from k=8 dimensions of the postcranial skeleton effectively satisfies all expectations of the Jolicoeur–Mosimann theorem of univariate and multivariate size. On the basis of strong parametric correlations between the k=8 variates and between scores derived from the first principal component and geometric mean size (GMSize in all series, this novel size variable has considerable utility in comparative vertebrate morphometrics and palaeobiology as an appropriate descriptor of individual size in extant and extinct taxa.

  16. A Small-scale Cross-sectional Study for the Assessment of Cardiorespiratory Fitness in Relation to Body Composition and Morphometric Characters in Fishermen of Araku Valley, Andhra Pradesh, India

    Directory of Open Access Journals (Sweden)

    Pallav Sengupta

    2014-01-01

    Conclusions: Findings of this small-scale population-based study indicated that health and physical fitness of young fishermen is under the influence of both occupational workload and nutritional status, as found by body composition and morphometric characters.

  17. Brain atrophy during aging. Quantitative studies with X-CT and NMR-CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuzawa, Taiju; Yamada, Kenji; Yamada, Susumu; Ono, Shuichi; Takeda, Shunpei; Hatazawa, Jun; Ito, Masatoshi; Kubota, Kazuo

    1985-12-01

    Age-related brain atrophy was investigated in thousands of persons with no neurologic disturbances using X-CT and NMR-CT. Brain atrophy was minimal in 34-35 years old in both sexes, increased exponentially to the increasing age after 34-35 years, and probably resulted in dementia, such as vascular or multi-infarct dementia. Brain atrophy was significantly greater in men than in women at all ages. Brain volumes were maximal in 34-35 years old in both sexes with minimal individual differences which increased proportionally to the increasing age. Remarkable individual differences in the extent of brain atrophy (20 - 30 %) existed among aged subjects. Progression of brain atrophy was closely related to loss of mental activities independently of their ages. Our longitudinal study has revealed that the most important factors promoting brain atrophy during aging was the decrease in the cerebral blood flow. We have classified brain atrophy into sulcal and cisternal enlargement type (type I), ventricular enlargement type (type II) and mixed type (type III) according to the clinical study using NMR-CT. Brain atrophy of type I progresses significantly in almost all of the geriatric disorders. This type of brain atrophy progresses significantly in heavy smokers and drinkers. Therefore this type of brain atrophy might be caused by the decline in the blood flow in anterior and middle cerebral arteries. Brain atrophy of type II was caused by the disturbance of cerebrospinal fluid circulation after cerebral bleeding and subarachnoid bleeding. Brain atrophy of type III was seen in vascular dementia or multi-infarct dementia which was caused by loss of brain matter after multiple infarction, and was seen also in dementia of Alzheimer type in which degeneration of nerve cells results in brain atrophy. NMR-CT can easily detect small infarction (lacunae) and edematous lesions resulting from ischemia and hypertensive encephalopathy. (J.P.N.).

  18. Fundamental studies for CT in the oral region

    International Nuclear Information System (INIS)

    Suzuki, Shinichiro

    1984-01-01

    Fundamental studies were attempted regarding the clinical application of CT (TCT-60A) in the oral region. The investigation assessed the following: 1) calculation of CT-No for oral hard tissues, 2) test for linearity CT-No vs. the linear attenuation coefficient in high X-ray attenuation materials, 3) observation of artifacts caused by dental materials and 4) measurement of patient doses of CT used at the maxillary sinus. The results obtained were as follows. 1) Calculated CT-No (E=70 KeV) values for oral hard tissues were enamel 3.51 x 10 3 , dentine 2.40 x 10 3 , cementum 1.88 x 10 3 , cortical bone 1.48 x 10 3 and mandible 1.01 x 10 3 . 2) Linearity for CT-No vs. the linear attenuation coefficient gave a good relative coefficient between lucite and teflon, but linearity between lucite and aluminum was not good enough. 3) Three different artifacts from the copper rod were observed: (1) connection line artifact, (2) star-burst artifact and (3) figure-eight artifact. 4) Under shot caused by composite resin was observed, and artifact from both the radiopaque composite resin and amalgam were the same kinds as those from the copper rod. 5) Calculated CT-No (E=66 KeV) values for dental materials were copper 5.48 x 10 4 , composite resin 1.24 x 10 3 , radiopaque composite resin 4.65 x 10 3 and amalgam 2.27 x 10 5 . 6) Absorbed doses of lenses and thyroid gland using CT at the mixillary sinus region were 59 mrad (59 x 10 -2 mGy) and 17 mrad (17 x 10 -2 mGy) for a single scanning. 7) The volume dose of the head under a single CT scanning was estimated as 820 g.rad (820 x 10 -5 Kg.Gy) by the TLD method, and 900 g.rad (900 x 10 -5 Kg.Gy) by the film dosimetry method. The difference in these values was considered to be the effect arising from ununiformity of the X-ray beam. (author)

  19. Morphometrics and Theriology. Homage to Marco Corti

    Directory of Open Access Journals (Sweden)

    Anna Loy

    2008-02-01

    Full Text Available Abstract This paper discusses the role of museum theriological collections in the context of twenty years of morphometric progresses. It also recalls twenty years of collaboration and friendship with Marco Corti, Italian theriologist and morphometrician, died on January 2007. The synthesis is addressed to the many young students that are picking up the baton and will likely contribute to the growth of the Italian school of morphometrics, to which Marco Corti dedicated most of his work at the University of Rome "La Sapienza". Riassunto Morfometria e teriologia. Omaggio a Marco Corti. Il lavoro discute il ruolo delle collezioni teriologiche alla luce di venti anni di progressi della morfometria. Esso rappresenta anche la sintesi di un’esperienza umana e professionale, avendo l’autore condiviso molte tappe della ‘rivoluzione morfometrica’ degli anni ottanta con molti dei suoi protagonisti, alcuni dei quali oggi non sono più con noi. In particolare Marco Corti, teriologo e morfometrista, scomparso nel 2007. La sintesi è anche dedicata ai molti giovani studenti e ricercatori che stanno contribuendo alla crescita della scuola italiana di morfometria, cui Marco Corti ha dedicato gli ultimi venti anni di insegnamento e ricerca all’Università di Roma "La Sapienza".

  20. Assessment of the relationships between morphometric characteristics of relief with quantitative and qualitative characteristics of forests using ASTER and SRTM digital terrain models

    Directory of Open Access Journals (Sweden)

    D. M. Chernikhovsky

    2017-06-01

    different sets of morphometric characteristics. The results of the study suggest the presence of relationships between characteristics of forests and morphometric characteristics of relief on different levels of forest management.

  1. ADJUSTMENT OF MORPHOMETRIC PARAMETERS OF WATER BASINS BASED ON DIGITAL TERRAIN MODELS

    Directory of Open Access Journals (Sweden)

    Krasil'nikov Vitaliy Mikhaylovich

    2012-10-01

    Full Text Available The authors argue that effective use of water resources requires accurate morphometric characteristics of water basins. Accurate parameters are needed to analyze their condition, and to assure their appropriate control and operation. Today multiple water basins need their morphometric characteristics to be adjusted and properly stored. The procedure employed so far is based on plane geometric horizontals depicted onto topographic maps. It is described in the procedural guidelines issued in respect of the «Application of water resource regulations governing the operation of waterworks facilities of power plants». The technology described there is obsolete due to the availability of specialized software. The computer technique is based on a digital terrain model. The authors provide an overview of the technique implemented at Rybinsk and Gorkiy water basins in this article. Thus, the digital terrain model generated on the basis of the field data is used at Gorkiy water basin, while the model based on maps and charts is applied at Rybinsk water basin. The authors believe that the software technique can be applied to any other water basin on the basis of the analysis and comparison of morphometric characteristics of the two water basins.

  2. Pulmonary actinomycosis: CT studies of diagnostic and post-treatment findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Jung; Song, Sun Wha; Bo, Seal Hwang; Park, Hyun Jin; Kim, Hyeon Sook; Kim, Ki Jun; Kim, Horrim; Park, Seog Hee [College of Medicine, the Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2008-05-15

    To investigate the value of the computed tomography (CT) in the study of diagnostic and post-treatment findings of pulmonary actinomycosis. Clinical data and CT findings were retrospectively analyzed in 10 patients with histopathologically confirmed pulmonary actinomycosis. We analyzed the initial CT findings in search of patterns and distributions which suggest possible lung abnormalities and found the pleura, chest wall, and lymphadenopathy to be involved as part of the indicators of lung abnormalities. We analyzed follow-up CT findings for changes in the lungs after antibiotic therapy and recurrence after surgery. Of the 10 patients analyzed by CT for lung lesions, seven had been diagnosed with alcoholism and nine were male. The initial CTs (n = 10) indicated that all the pulmonary lesions were solitary without chest wall involvement. However, a transfissural extension was observed in 20% of the study population (n = 2). Furthermore, peripheral lung distribution and adjacent pleural thickening was observed in 70% of the study population (n = 7). Within the consolidation (n = 6) or mass (n = 4), a central low density with peripheral enhancement was seen in 70% of the study population (n = 7). A follow-up CT of the seven cases following antiobiotic therapy revealed that four cases showed minimal improvement or aggravation of their lung lesions, whereas three cases showed resolution or improvement. The improvement of the central low density was related to the improvement of consolidation or mass. Furthermore the presence of fibrosis was observed after the resolution of pulmonary lesions (n = 2). No relationship was found between the duration and response of antibiotic therapy. A follow-up CT (n = 4) subsequent to a lung resection revealed the onset of chest wall actinomycosis and a thickened pleura in one case. The results of this study highlight the value of the CT in pulmonary actinomycosis in order to diagnose and evaluate antibiotic responses, complications, or

  3. Morphometric Variations in the Grasshopper, Chromacris speciosa from Two Localities of Pernambuco in Northeastern Brazil

    Science.gov (United States)

    Cisneiros, Roberta Araújo; de Almeida, Argus Vasconcelos; de Melo, Gabriel Rivas; da Câmara, Cláudio Augusto Gomes

    2012-01-01

    The present study describes morphometric variations in the grasshopper, Chromacris speciosa (Thunberg, 1824) (Orthoptera: Acridoidea: Romaleidae) from two locations in the state of Pernambuco, Brazil. The distance between the sites chosen for collections (Recife and São Lourenço da Mata) is approximately 16 km. The investigation was based on a comparative study of external morphological characteristics of the grasshoppers. Morphometric measurements took into account the different body parts and appendages. Statistical analysis of the measurements revealed significant differences in the size of the specimens between the two locations. Homogeneity tests of the covariance and equality matrices between mean vectors of the results revealed that the grasshopper populations in Recife and São Lourenço da Mata are distinctly different. These findings provide morphological evidence for intraspecific variation in morphological characteristics of the C. speciosa populations from the two locations. PMID:23421530

  4. Morphometric analysis of the arteries of Willis Polygon

    Directory of Open Access Journals (Sweden)

    Canaz Huseyin

    2018-03-01

    Full Text Available Objective: Willis polygon forms the basis of the arterial circulation of the cerebrum. Willis polygon is a vascular structure whom variations are not rare. Knowledge of the anatomy and preservation of its integrity is crucial for performing neurovascular surgery and intracranial tumour surgery. Because of the important vascular and neurological structures, approaches to this region are considered extremely risky. One of the main variations in-person basis is the diameter differences of the arteries, which forms Willis polygon, between the left and right hemispheres. About structure and variations, studies of Rhoton and Yasargil had formed the touchstone. Our aim is to contribute to the literature and clinical studies, to be done in the future, by comparing our results with previous studies about variations and morphometric features of Willis polygon.

  5. Study of dosimetry CT in Skull for pediatric patients

    International Nuclear Information System (INIS)

    Ramos Amores, D.; Serna Berna, A.; Mata Colodro, F.; Puchades Puchades, V.

    2013-01-01

    The dose that receiving the patients in CT studies is the highest that can be received in a study of Radiology. If patients are children and we do studies with the same parameters as adults, they will receive a higher dose of radiation. This work seeks to expose the result of a dosimetric study on CT for children aged 0-15, carried out at the Hospital General Universitario de Santa Lucia in Cartagena during the year 2012. (Author)

  6. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    Science.gov (United States)

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  7. Morphometric findings in avascular necrosis of the femoral head.

    Science.gov (United States)

    Kamal, Diana; Trăistaru, Rodica; Alexandru, D O; Kamal, C K; Pirici, D; Pop, O T; Mălăescu, D Gh

    2012-01-01

    Avascular necrosis of the femoral head is an illness with a controversial etiology, the trigger event being the suppression of blood flow to the femoral head. The disease affects mostly young adults within their third and fifth decade, the majority of the patients being men. The main risk factors are trauma, chronic alcohol consumption, smoking, corticotherapy. The main goal of our study is to describe the morphometric changes found in the bone tissue of patients diagnosed with avascular necrosis of the femoral head, with different risk factors, by comparing the area of bone trabeculae inside the area of necrosis with that from the adjacent viable tissue. The morphometric study used biological material from 16 patients with ages between 29 and 57 years, who underwent surgery for avascular necrosis of the femoral head. They were admitted in the Orthopedics Department at the Emergency County Hospital in Craiova between 2010 and 2011 and were split into four groups. Group I presented trauma as the main risk factor, Group II had corticotherapy as the defining risk factor, Group III presented chronic alcohol consumption and Group IV was represented by the patients who smoked and exhibited chronic alcohol consumption. There was not a significant statistical difference between the areas of bone trabeculae of the four groups when we compared viable bone tissue to the necrotized one. Knowing the risk factors of the avascular necrosis of the femoral head is critical to the management of the disease, because diagnosing it in an early stage is a necessity for obtaining a good result for conservative treatment.

  8. Population differentiation of the shore crab Carcinus maenas (Brachyura: Portunidae on the southwest English coast based on genetic and morphometric analyses

    Directory of Open Access Journals (Sweden)

    Inês C. Silva

    2010-08-01

    Full Text Available Carcinus maenas has a planktonic larval phase which can potentially disperse over large distances. Consequently, larval transport is expected to play an important role in promoting gene flow and determining population structure. In the present study, population structuring on the southwest coast of England was analysed using molecular and morphometric approaches. Variation at eight microsatellite loci suggested that the individuals sampled within this region comprise a single genetic population and that gene flow among them is not restricted. Nevertheless, the FST values estimated across loci for all populations suggested that the Tamar population was significantly different from the Exe, Camel and Torridge populations. This differentiation is not explained by isolation by distance, and coastal hydrological events that are apparently influencing larval flux might be the cause of this pattern. Morphometric analysis was also performed. Analysis of carapace and chela shape variation using landmark-based geometric morphometrics revealed extensive morphological variability, as the multivariate analysis of variance showed significant morphometric differences among geographic groups for both sexes. Thus, the morphological differentiation found may be a plastic response to habitat-specific selection pressures.

  9. Studies of extracerebral space on brain CT of infants

    International Nuclear Information System (INIS)

    Shibakiri, Ippei; Furukawa, Takashi; Fukakusa, Shunichi; Nemoto, Yutaka; Takashima, Sumio.

    1983-01-01

    Frontal extracerebral space (ECS) is frequently noticed on brain CT of infants. Based on 70 infants whose initial CTs were available under 1 year of age and who were observed serially by brain CT, we studied the relation between degrees of ECS enlargement and mental and physical development of infants. Development was assessed by clinical observation and the mental test according to Tsumori and Inage at about 1 year of age. 1) Under 1 year of age, ECS was observed both in the normally developed infants and the infants with retarded development. At 1 year of age, CT of the former showed no or only mild widening, but most CT of the latter showed marked dilatation of ECS. 2) Serial observation of brain CT revealed that ECS of normally developed infants tended to reduce at 1 year of age, but that of infants with retarded development did not. 3) Regarding prediction of infantile development, it is important to observe presence of ECS and of the tendency to reduce on brain CT at 1 year of age. 4) Appearance of ECS of normally developed infants is considered to be a physiological phenomenon. (author)

  10. Correlative CT and anatomic study of the sciatic nerve

    International Nuclear Information System (INIS)

    Pech, P.; Haughton, V.

    1985-01-01

    Sciatica can be caused by numerous processes affecting the sciatic nerve or its components within the pelvis including tumors, infectious diseases, aneurysms, fractures, and endometriosis. The CT diagnosis of these causes of sciatica has not been emphasized. This study identified the course and appearance of the normal sciatic nerve in the pelvis by correlating CT and anatomic slices in cadavers. For purposes of discussion, the sciatic nerve complex is conveniently divided into three parts: presacral, muscular, and ischial. Each part is illustrated here by two cryosections with corresponding CT images

  11. Wing morphometrics as a possible tool for the diagnosis of the Ceratitis fasciventris, C. anonae, C. rosa complex (Diptera, Tephritidae).

    Science.gov (United States)

    Van Cann, Joannes; Virgilio, Massimiliano; Jordaens, Kurt; De Meyer, Marc

    2015-01-01

    Previous attempts to resolve the Ceratitis FAR complex (Ceratitis fasciventris, Ceratitis anonae, Ceratitis rosa, Diptera, Tephritidae) showed contrasting results and revealed the occurrence of five microsatellite genotypic clusters (A, F1, F2, R1, R2). In this paper we explore the potential of wing morphometrics for the diagnosis of FAR morphospecies and genotypic clusters. We considered a set of 227 specimens previously morphologically identified and genotyped at 16 microsatellite loci. Seventeen wing landmarks and 6 wing band areas were used for morphometric analyses. Permutational multivariate analysis of variance detected significant differences both across morphospecies and genotypic clusters (for both males and females). Unconstrained and constrained ordinations did not properly resolve groups corresponding to morphospecies or genotypic clusters. However, posterior group membership probabilities (PGMPs) of the Discriminant Analysis of Principal Components (DAPC) allowed the consistent identification of a relevant proportion of specimens (but with performances differing across morphospecies and genotypic clusters). This study suggests that wing morphometrics and PGMPs might represent a possible tool for the diagnosis of species within the FAR complex. Here, we propose a tentative diagnostic method and provide a first reference library of morphometric measures that might be used for the identification of additional and unidentified FAR specimens.

  12. Aortic non communicating dissections. A study with helical CT

    International Nuclear Information System (INIS)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G.; D'Agostino, D.; De Luca Tupputi Schinosa, L.

    2000-01-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  13. MORPHOMETRIC ASPECTS IN THE BÂRLAD BASIN

    Directory of Open Access Journals (Sweden)

    BĂLAN OANA

    2015-03-01

    Full Text Available Bârlad valley morphometry is strongly influenced by lithology, geological structure and climatic conditions. Between its springs and the outflow we noticed notable deviations from valley monocline structure and from the consecvent overall direction of the river system. Morphometric analysis of the Bârlad valley cumulates and summarizes the sequence of events that occurred in its hydrographic basin, which in turn has been actively reflected in indices such as generated the altimetry, the relief depth fragmentation.

  14. Early prediction of therapy response and disease free survival after induction chemotherapy in stage III non-small cell lung cancer by FDG-PET: Correlation between tumor FDG-metabolism and morphometric tumor response

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Niesen, A.; Przetak, C.; Griesinger, F.

    2002-01-01

    Aim: Chemotherapy with Docetaxel and Carboplatin (DC) has shown high response rates in advanced non-small cell lung cancer (NSCLC). Histologic tumor response after chemotherapy or combined chemoradiotherapy is strongly associated with systemic tumor control and potentially cure. Metabolic tumor response assessed by FDG-PET after induction VIP-chemotherapy has been shown to be predictive of outcome in NSCLC. The aim of the present study was to correlate the tumor FDG metabolism as measured by F-18 FDG-PET with morphometric findings after DC induction chemotherapy plus Erythropoietin (10,000 IU Epo s.c. three times a week). Material and Methods: In this prospective multicenter study, 54 patients with NSCLC stage IIIA (9 patients) or IIIB (45 patients) were enrolled and received neoadjuvant treatment with D 100 mg/m 2 d1 and C AUC 7.5 d2 q21 days for 4 cycles prior to surgery. Postoperatively, all patients received adjuvant radiotherapy. WB-PET-studies (ECAT Exact 47) were obtained p.i. of 400 MBq F-18 FDG. Standardized uptake values (SUV), metabolic tumor diameter (MTD) and metabolic tumor index (MTI SUV x MTD) were assessed. Image fusion of PET and CT data was applied on a HERMES computer. Results: Of 54 enrolled patients, 46 were evaluable for response by CT. 30/46 patients (65%) achieved complete remission (CR, 1 patient) or partial remission (PR 29 patients.). Of the 46 patients, 37 patients completed neoadjuvant chemotherapy (Chx) and were studied before and after Chx by FDG-PET. 14 (30% of the 46 evaluable patients) had SUV < 2.5, corresponding to metabolic complete remission (mCR), 23 had PR or stable disease (non-mCR); in 9 patients, PET was not performed because of progressive disease demonstrated by CT. The R0-resection rate was 56% (27/48 evaluable patients). Of the 14 patients with metabolic CR, 9 were evaluated by morphometry. All had regression grades III (no vital tumor cells) or grade IIB (< 10% vital tumor cells and induced apoptosis). With a median

  15. Hip shape is symmetric, non-dependent on limb dominance and gender-specific. Implications for femoroacetabular impingement. A 3D CT analysis in asymptomatic subjects

    International Nuclear Information System (INIS)

    Mascarenhas, Vasco V.; Rego, Paulo; Dantas, Pedro; Castro, Miguel; Jans, Lennart; Marques, Rui M.; Gouveia, Nelia; Consciencia, Jose G.; Soldado, Francisco; Ayeni, Olufemi R.

    2018-01-01

    To determine the reference intervals (RefInt) of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in asymptomatic hips with computed tomography (CT) and determine their dependence on age, side, limb dominance and sex. We prospectively included 590 patients and evaluated 1111 hips with semi-automated CT analysis. We calculated overall, side- and sex-specific parameters for imaging signs of cam [omega and alpha angle (α )] and pincer-type morphology [acetabular version (ACvers), lateral centre-edge angle (LCEA) and cranio-caudal coverage]. Hip shape was symmetrical and did not depend on limb dominance. The 95% RefInt limits were sex-different for all cam-type parameters and extended beyond current abnormal thresholds. Specifically, the upper limits of RefInt for α at 12:00, 1:30 and 3:00 o'clock positions were 56 , 70 and 58 , respectively, and 45 for LCEA. Acetabular morphology varied between age groups, with a trend toward an LCEA/ACvers increase over time. Our morphometric measurements can be used to estimate normal hip morphology in asymptomatic individuals. Notably they extended beyond current thresholds used for FAI imaging diagnosis, which was most pronounced for cam-type parameters. We suggest the need to reassess α RefInt and consider a 60 threshold for the 12:00/3:00 positions and 65-70 for other antero-superior positions. (orig.)

  16. Morphometric and functional abnormalities of kidneys in the progeny of mice fed chocolate during pregnancy and lactation.

    Directory of Open Access Journals (Sweden)

    Ewa Skopińska-Rózewska

    2006-09-01

    Full Text Available Even most commonly consumed beverages like tea, coffee, chocolate and cocoa contain methylxanthines, biogenic amines and polyphenols, among them catechins, that exhibit significant biological activity and might profoundly affect the organism homeostasis. We have previously shown that 400 mg of bitter chocolate or 6 mg of theobromine added to the daily diet of pregnant and afterwards lactating mice affected embryonic angiogenesis and caused bone mineralization disturbances as well as limb shortening in 4-weeks old offspring. The aim of the present study was the morphometric and functional evaluation of kidneys in the 4-weeks old progeny mice fed according to the protocol mentioned above. Progeny from the mice fed chocolate presented considerable morphometric abnormalities in the kidney structure, with the lower number of glomeruli per mm2 and their increased diameter. Moreover, higher serum creatinine concentration was observed in that group of offspring. No morphometric or functional irregularities were found in the progeny of mice fed theobromine. Abnormalities demonstrated in the offspring of mice fed chocolate are not related to its theobromine content. Consequently, identification of active compound(s responsible for the observed effects is of vital importance.

  17. Applications of Micro-CT scanning in medicine and dentistry: Microstructural analyses of a Wistar Rat mandible and a urinary tract stone

    Science.gov (United States)

    Latief, F. D. E.; Sari, D. S.; Fitri, L. A.

    2017-08-01

    High-resolution tomographic imaging by means of x-ray micro-computed tomography (μCT) has been widely utilized for morphological evaluations in dentistry and medicine. The use of μCT follows a standard procedure: image acquisition, reconstruction, processing, evaluation using image analysis, and reporting of results. This paper discusses methods of μCT using a specific scanning device, the Bruker SkyScan 1173 High Energy Micro-CT. We present a description of the general workflow, information on terminology for the measured parameters and corresponding units, and further analyses that can potentially be conducted with this technology. Brief qualitative and quantitative analyses, including basic image processing (VOI selection and thresholding) and measurement of several morphometrical variables (total VOI volume, object volume, percentage of total volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity) were conducted on two samples, the mandible of a wistar rat and a urinary tract stone, to illustrate the abilities of this device and its accompanying software package. The results of these analyses for both samples are reported, along with a discussion of the types of analyses that are possible using digital images obtained with a μCT scanning device, paying particular attention to non-diagnostic ex vivo research applications.

  18. Magnetic resonance imaging in schizophrenia: a morphometric study; Ressonancia magnetica na esquizofrenia: um estudo morfometrico

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Claudio Campi de [Sao Paulo Univ., SP (Brazil). Instituto do Coracao (InCor). Secao de Ressonancia Magnetica]. E-mail: campi@uol.com.br

    2001-06-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  19. Ethnical evaluation of Bangladeshi young adults in terms of morphometrically-analyzed craniofacial skeleton

    Directory of Open Access Journals (Sweden)

    Hasan Md. Rizvi

    2013-01-01

    Full Text Available Morphometric study for the craniofacial relations and variations in humans have long been used to differentiate various racial groups in physical anthropology. The objective of this study was to describe the morphological features of craniofacial skeleton in Bangladeshi young adults and to compare it with already reported standards for the Caucasian population as well as cephalometric values of other Indian races using Steiner′s reference norms. The study was conducted for 52 Bangladeshi young adults (27 male and 25 females, aged 21-27 years, having balanced and harmonious facial profiles, clinically acceptable occlusion with permanent dentition and no history of orthodontic treatment. Lateral cephalograms taken of these subjects were used for a series of morphometric analyses. Bangladeshi subjects were more protrusive skeletally and dentally than Caucasians. Furthermore, the mandibular plane angle was smaller in Bangladeshi subjects than in the Caucasians. Present results also suggest that the Astrics, Dravidians, and Armenoid who penetrated into Bengal in the early ages may have contributed substantially to the morphogenesis of craniofacial skeleton in the present Bengalis. The results of this study support the idea that a single standard of facial esthetics should not be applied to all racial and ethnic groups.

  20. Identification of the species of the Cheilosia variabilis group (Diptera, Syrphidae) from the Balkan Peninsula using wing geometric morphometrics, with the revision of status of C. melanopa redi Vujic, 1996

    NARCIS (Netherlands)

    Francuski, Lj.; Vujic, A.; Kovacevic, A.; Ludoski, J.; Milankov, V.

    2009-01-01

    The present study investigates phenotypic differentiation patterns among four species of the Cheilosia variabilis group (Diptera, Syrphidae) using a landmark-based geometric morphometric approach. Herein, wing geometric morphometrics established species boundaries that confirm C. melanopa and C.

  1. Correlation of FDG-PET measurements with morphometric tumor response after induction chemotherapy and adjuvant radiotherapy in stage III non-small cell lung cancer (NSCLC)

    International Nuclear Information System (INIS)

    Baum, R.P.; Niesen, A.; Griesinger, F.

    2002-01-01

    Full text: Docetaxel (D) and carboplatin (C) combination chemotherapy (DC) has shown high response rates in advanced NSCLC. Histologic tumor response after chemotherapy or combined modality induction is strongly associated with systemic tumor control and potentially cure. Metabolic tumor response assessed by FDG-PET after induction chemotherapy with etoposide, ifosfamide and cisplatin (VIP) has been shown to be predictive of outcome in NSCLC. Finally, erythropoietin (EPO) may prevent the decrease in hemoglobin levels that was seen in a previous study of DC (median drop 2.7 g/dl) and thus may enhance treatment efficacy. The aim of the present study was to correlate FDG-PET studies with histomorphometric findings after DC induction chemotherapy plus Epo. 33 patients (pts) with NSCLC stage IIIA (7 pts) or IIIB (24 pts) were enrolled and received treatment with D 100 mg/m 2 dl and C AUC 7.5 d2 q21 days for 4 cycles. Epo was given at 10,000 IU s.c. three times a week. All pts received adjuvant radiotherapy. Of 33 enrolled patients, 22 were evaluable for response by CT imaging. 14/22 pts (64 %) achieved PR. Of the 22 responders, 20 were evaluable for repeated FDG-PET studies. 13/20 pts had a decrease of standardized uptake values (SUV) and of the metabolic tumor index (MTI) by >50 %, 9/20 had SUV <2.5 (CR). Seven of these 9 pts underwent tumor resection, and specimens were subjected to morphometric analysis. In 7/7 cases, no vital tumor cells were detected in the specimens. In contrast to our previous study, hemoglobin levels increased by a median of 0.3 g/dl. Morphometric tumor response after induction chemotherapy correlates strongly with metabolic remission by FDG-PET. FDG-PET appears to be a useful non-invasive diagnostic tool to predict pathologic response and potentially long-term outcome in stage III NSCLC. (author)

  2. Experimental chronic entrapment of the sciatic nerve in adult hamsters: an ultrastructural and morphometric study

    Directory of Open Access Journals (Sweden)

    Prinz R.A.D.

    2003-01-01

    Full Text Available Entrapment neuropathy is a group of clinical disorders involving compression of a peripheral nerve and interference with nerve function mostly through traction injury. We have investigated the chronic compression of peripheral nerves as an experimental procedure for detecting changes in ultrastructural nerve morphology. Adult hamsters (Mesocricetus auratus, N = 30 were anesthetized with a 25% pentobarbital solution and received a cuff around the right sciatic nerve. Left sciatic nerves were not operated (control group. Animals survived for varying times (up to 15 weeks, after which they were sacrificed and both sciatic nerves were immediately fixed with a paraformaldehyde solution. Experimental nerves were divided into segments based upon their distance from the site of compression (proximal, entrapment and distal. Semithin and ultrathin sections were obtained and examined by light and electron microscopy. Ultrastructural changes were qualitatively described and data from semithin sections were morphometrically analyzed both in control and in compressed nerves. We observed endoneurial edema along with both perineurial and endoneurial thickening and also the existence of whorled cell-sparse structures (Renaut bodies in the subperineurial space of compressed sciatic nerves. Morphometric analyses of myelinated axons at the compression sites displayed a remarkable increase in the number of small axons (up to 60% in comparison with the control axonal number. The distal segment of compressed nerves presented a distinct decrease in axon number (up to 40% comparatively to the control group. The present experimental model of nerve entrapment in adult hamsters was shown to promote consistent histopathologic alterations analogous to those found in chronic compressive neuropathies.

  3. How effective are geometric morphometric techniques for assessing functional shape variation? An example from the great ape temporomandibular joint.

    Science.gov (United States)

    Terhune, Claire E

    2013-08-01

    Functional shape analyses have long relied on the use of shape ratios to test biomechanical hypotheses. This method is powerful because of the ease with which results are interpreted, but these techniques fall short in quantifying complex morphologies that may not have a strong biomechanical foundation but may still be functionally informative. In contrast, geometric morphometric methods are continually being adopted for quantifying complex shapes, but they tend to prove inadequate in functional analyses because they have little foundation in an explicit biomechanical framework. The goal of this study was to evaluate the intersection of these two methods using the great ape temporomandibular joint as a case study. Three-dimensional coordinates of glenoid fossa and mandibular condyle shape were collected using a Microscribe digitizer. Linear distances extracted from these landmarks were analyzed using a series of one-way ANOVAs; further, the landmark configurations were analyzed using geometric morphometric techniques. Results suggest that the two methods are broadly similar, although the geometric morphometric data allow for the identification of shape differences among taxa that were not immediately apparent in the univariate analyses. Furthermore, this study suggests several new approaches for translating these shape data into a biomechanical context by adjusting the data using a biomechanically relevant variable. Copyright © 2013 Wiley Periodicals, Inc.

  4. A Retrospective 2D Morphometric Analysis of Adult Female Chiari Type I Patients with Commonly Reported and Related Conditions

    Directory of Open Access Journals (Sweden)

    Maggie S. Eppelheimer

    2018-01-01

    Full Text Available Purpose: Researchers have sought to better understand Chiari type I malformation (CMI through morphometric measurements beyond tonsillar position (TP. Soft tissue and bone structures within the brain and craniocervical junction have been shown to be different for CMI patients compared to healthy controls. Yet, several morphological characteristics have not been consistently associated with CMI. CMI is also associated with different prevalent conditions (PCs such as syringomyelia, pseudotumor, Ehlers-Danlos syndrome (EDS, scoliosis, and craniocervical instability. The goal of this study was two-fold: (1 to identify unique morphological characteristics of PCs, and (2 to better explain inconsistent results from case-control comparisons of CMI.Methods: Image, demographic, and PC information was obtained through the Chiari1000, a self-report web-accessed database. Twenty-eight morphometric measurements (MMs were performed on the cranial MR images of 236 pre-surgery adult female CMI participants and 140 female healthy control participants. Custom software was used to measure 28 structures within the posterior cranial fossa (PCF compartment, craniocervical junction, oral cavity, and intracranial area on midsagittal MR images for each participant.Results: Morphometric analysis of adult females indicated a smaller McRae line length in CMI participants with syringomyelia compared to those without syringomyelia. TP was reduced in CMI participants with EDS than those without EDS. Basion to posterior axial line was significantly longer in CMI participants with scoliosis compared to those without scoliosis. No additional MMs were found to differ between CMI participants with and without a specific PC. Four morphometric differences were found to be consistently different between CMI participants and healthy controls regardless of PC: larger TP and a smaller clivus length, fastigium, and corpus callosum height in CMI participants.Conclusion: Syringomyelia, EDS

  5. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    Science.gov (United States)

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  6. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  7. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    Directory of Open Access Journals (Sweden)

    Moritz Kaup

    2016-12-01

    Full Text Available Background Computed tomography (CT low-dose (LD imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA. Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR and signal-to-noise ratios (SNR were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy. Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768. Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4. Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

  8. Effect of Genotype and Age on Some Morphometric, Body Linear ...

    African Journals Online (AJOL)

    A population of 231 roosters of the Nigerian indigenous chickens of normal feathered frizzle feathered and naked neck genotypes was evaluated for the effect of genotype and age on some morphometric body linear measurements and semen characteristics of three Nigerian chicken genotypes. 20 roosters from each ...

  9. Influence of delayed placement and dietary lysine levels on small intestine morphometrics and performance of broilers

    Directory of Open Access Journals (Sweden)

    JRG Franco

    2006-12-01

    Full Text Available This experiment studied the influence of delayed placement (HI and digestible lysine level (DL on the morphometrics of the intestinal mucosa and on the performance of broilers. A total number of 1,705 Cobb 500 male chicks were used in a completely randomized experimental design in a factorial arrangement with four HI (12, 24, 36 and 48h, and two DL level in the starter diet (1.143 and 1.267%, with four replicates and 55 birds per experimental unit. The amino acids methionine-cystine, threonine, and tryptophan were balanced according to the ideal protein (IP concept. Small intestine morphometrics was evaluated using histology slides of the duodenum and jejunum. There was no interaction between HI and DL levels for any of the studied parameters. The 1.143% level of DL promoted better performance results at 21 and 42 days of age, as well as higher duodenum and jejunum crypt depth, and duodenum villi height at 21 days of age. HI negatively influenced the morphometrics of the small intestine during the starter phase, and the performance of broilers up to 42 days of age. There was no effect of the treatments on yolk sac utilization or abdominal fat percentage. It was concluded that the use of 1.143% DL and HI of 12 hours promoted better development of the small intestine mucosa up to 21 days of age, and broiler performance at market age.

  10. Machine Learning for Nuclear Mechano-Morphometric Biomarkers in Cancer Diagnosis.

    Science.gov (United States)

    Radhakrishnan, Adityanarayanan; Damodaran, Karthik; Soylemezoglu, Ali C; Uhler, Caroline; Shivashankar, G V

    2017-12-20

    Current cancer diagnosis employs various nuclear morphometric measures. While these have allowed accurate late-stage prognosis, early diagnosis is still a major challenge. Recent evidence highlights the importance of alterations in mechanical properties of single cells and their nuclei as critical drivers for the onset of cancer. We here present a method to detect subtle changes in nuclear morphometrics at single-cell resolution by combining fluorescence imaging and deep learning. This assay includes a convolutional neural net pipeline and allows us to discriminate between normal and human breast cancer cell lines (fibrocystic and metastatic states) as well as normal and cancer cells in tissue slices with high accuracy. Further, we establish the sensitivity of our pipeline by detecting subtle alterations in normal cells when subjected to small mechano-chemical perturbations that mimic tumor microenvironments. In addition, our assay provides interpretable features that could aid pathological inspections. This pipeline opens new avenues for early disease diagnostics and drug discovery.

  11. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  12. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  13. Morphometric analysis of hypoglossal canal of the occipital bone in Iranian dry skulls

    Directory of Open Access Journals (Sweden)

    Bayat Parvindokht

    2015-01-01

    Full Text Available Background: The hypoglossal canal (HC is in basal part of cranium that transmits the nerve that supplies the motor innervations to the muscles of tongue. Study on morphometry of (HC and its variations has been a considerable interest field to neurosurgeons and research workers especially because of their racial and regional. Material and Methods: In this retrospective study, 26 adult dry human crania of no sex known were studied for (HC and its variants. Thirty five skulls were observed for any damage of post cranial fossa and those in good condition (26 skullswere selected. Sliding Vernier caliper was used for morphometric analysis. Results: There were significant difference between distances of: a-(HC till anterior tip of condyles (right and left, b-(HC till posterior tip of condyles (right and left, c-(HCtill lower border of occipital condyles (right and left, d-(HC till external border of foramen jugular (right and left, e-(HC till opisthion(right and left, f-(HC till carotid canal (right and left, g-(HC till jugular tubercle (right and left. There wasn′t significant difference in other parameters. Conclusion: Detailed morphometric analysis of (HC will help in planning of surgical intervention of skull base in safer and easier ways.

  14. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    International Nuclear Information System (INIS)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille; Liozon, Eric; Ly, Kim Heang; Lambert, Marc; Aide, Nicolas; Manrique, Alain

    2017-01-01

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  15. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    Energy Technology Data Exchange (ETDEWEB)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille [Caen University Hospital, Department of Internal Medicine, Caen (France); Liozon, Eric; Ly, Kim Heang [Limoges University Hospital, Department of Internal Medicine, Limoges (France); Lambert, Marc [Lille University Hospital, Department of Internal Medicine, Lille (France); Aide, Nicolas [Caen University Hospital, Department of Nuclear Medicine, Caen (France); INSERM U1086 ' ' ANTICIPE' ' , Francois Baclesse Cancer Centre, Caen (France); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Caen (France); Normandy University, Caen (France)

    2017-12-15

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  16. A study on CT-guided stereotactic technique for functional neurosurgery

    International Nuclear Information System (INIS)

    Uetsuhara, Koichi; Asakura, Tetsuhiko; Hirahara, Kazuho; Gondo, Masazumi; Oda, Hiroshige

    1987-01-01

    Recently, CT-guided stereotactic surgery has become of major interest, and some authors have discussed its potential in functional neurosurgery. The following is a comparative study of the CT-guided stereotactic technique and the conventional roentogenographic stereotactic technique. The Brown-Roberts-Wells apparatus was used for both types of procedures. 37 stereotactic procedures were performed on 35 patients under local anesthesia; 16 for stereotactic biopsy and 21 for stereotactic functional neurosurgery. Target points for stereotactic biopsy were determined by the CT-guided technique and target points for functional neurosurgery were determined by the conventional roentogenographic technique. The correlation with the position of target point determined by both techniques was investigated in the 21 functional neurosurgical procedures. On these occasions the authors used the reformatted horizontal and sagittal CT through the anterior and posterior commissure to determine the position of target point by the CT-guided technique. Results: It was found that the AC-PC line crossed with Reid's base line at angle of 11 ± 1 deg, and therefore it is important to obtain a CT images including AC-PC line at this angle. When applying the CT guided stereotactic procedure for functional surgery, it should be known that there could be a discrepancy within 2 mm from the conventional target determination. (author)

  17. Morphometric Analysis of Mandibular Growth in Skeletal Class III Malocclusion

    Directory of Open Access Journals (Sweden)

    Jenny Zwei-Chieng Chang

    2006-01-01

    Conclusion: We conclude that thin-plate spline analysis and the finite element morphometric method are efficient for the localization and quantification of size and shape changes that occur during mandibular growth. Plots of maximum and minimum principal directions can provide useful information about the trends of growth changes.

  18. Technical note: a landmark-based approach to the study of the ear ossicles using ultra-high-resolution X-ray computed tomography data.

    Science.gov (United States)

    Schmidt, Jodi L; Cole, Theodore M; Silcox, Mary T

    2011-08-01

    Previous study of the ear ossicles in Primates has demonstrated that they vary on both functional and phylogenetic bases. Such studies have generally employed two-dimensional linear measurements rather than three-dimensional data. The availability of Ultra- high-resolution X-ray computed tomography (UhrCT) has made it possible to accurately image the ossicles so that broadly accepted methodologies for acquiring and studying morphometric data can be applied. Using UhrCT data also allows for the ossicular chain to be studied in anatomical position, so that it is possible to consider the spatial and size relationships of all three bones. One issue impeding the morphometric study of the ear ossicles is a lack of broadly recognized landmarks. Distinguishing landmarks on the ossicles is difficult in part because there are only two areas of articulation in the ossicular chain, one of which (the malleus/incus articulation) has a complex three-dimensional form. A measurement error study is presented demonstrating that a suite of 16 landmarks can be precisely located on reconstructions of the ossicles from UhrCT data. Estimates of measurement error showed that most landmarks were highly replicable, with an average CV for associated interlandmark distances of less than 3%. The positions of these landmarks are chosen to reflect not only the overall shape of the bones in the chain and their relative positions, but also functional parameters. This study should provide a basis for further examination of the smallest bones in the body in three dimensions. Copyright © 2011 Wiley-Liss, Inc.

  19. Prevalence of incidental or unexpected findings on low-dose CT performed during routine SPECT/CT nuclear medicine studies

    International Nuclear Information System (INIS)

    Yap, Kelvin Kwok-Ho; Sutherland, Tom; Shafik-Eid, Raymond; Taubman, Kim; Schlicht, Stephen; Ramaseshan, Ganeshan

    2015-01-01

    In nuclear medicine, single-photon-emission computed tomography (SPECT) is often combined with ‘simultaneous’ low-dose CT (LDCT) to provide complementary anatomical and functional correlation. As a consequence, numerous incidental and unexpected findings may be detected on LDCT. Recognition of these findings and appropriate determination of their relevance can add to the utility of SPECT/CT. We aimed to evaluate the prevalence and categorise the relevance of incidental and unexpected findings on LDCT scans performed as part of routine SPECT/CT studies. All available LDCT scans performed as part of SPECT/CT studies at St. Vincent's Hospital Melbourne in the year 2013 were retrospectively reviewed. Two qualified radiologists independently reviewed the studies and any previous available imaging and categorised any detected incidental findings. A total of 2447 LDCT studies were reviewed. The relevance of the findings was classified according to a modified version of a scale used in the Colonography Reporting and Data System: E1 = normal or normal variant (28.0%); E2 = clinically unimportant (63.5%); E3 = likely unimportant or incompletely characterised (6.2%); E4 = potentially important (2.5%). Imaging specialists need to be cognisant of incidental and unexpected findings present on LDCT studies performed as part of SPECT/CT. Appropriate categorisation of findings and communication of potentially important findings to referring clinicians should form part of routine practice. The overall prevalence of potentially significant incidental and unexpected findings in our series was 8.7% (E3, 6.2%; E4, 2.5%) and was comparable to rates in other published imaging series.

  20. Sperm morphological and morphometric evaluation in captive collared peccaries (Pecari tajacu

    Directory of Open Access Journals (Sweden)

    Patrícia C. Sousa

    2013-07-01

    Full Text Available The aim of this study was to compare different staining methods for the evaluation of sperm morphology by light microscopy and also to describe the morphometry of the entire sperm in collared peccaries (Pecari tajacu. Semen from 10 males was obtained by electroejaculation and evaluated for sperm motility, vigor, and concentration. Semen smears were prepared through three different staining methods: Bengal rose, brome-phenol blue, and eosin-nigrosin. Smears were evaluated under light microscopy and sperm morphologic alterations were determined in percentage. In addition, sperm morphometric analysis was conducted by light microscopy coupled to image analyzer software. The smears stained with Bengal Rose provide the best results for the visualization of the sperm tail, midpiece, and head. The use of eosin-nigrosin stain did not allow an adequate impregnation, and some sperm presented a few contrasts with the background. A higher incidence of bent coiled tails was verified in the use of brome-phenol blue staining (P<0.05. Through morphometric evaluation, it was observed that the tail occupies the greatest proportion (89% of the sperm which presents a discretely elongated head. According to the results, the use of the Bengal Rose stain is recommended for the morphologic evaluation of the collared peccary sperm.

  1. ANALYSIS OF MORPHOMETRIC PARAMETERS OF THE ROE DEER MANDIBLE (Capreolus capreolus AND MANDIBLE OF THE SHEEP (Ovis aries

    Directory of Open Access Journals (Sweden)

    Rizah Avdić

    2013-08-01

    Full Text Available Morphology and morphometry of the bones are the methods often used for identification of species, estimation of animals' age, and genetic and forensic investigation. The mandible as the largest bone of the head is perhaps the most representative sample for this research. The aim of this study was to determine the basic morphometric parameters of the mandible of roe deer and sheep in order to identify the species. All samples were described by linear measure morphometric analysis of 12 specific anatomical points on the mandibles of roe deer and sheep. The results obtained are presented in the Table as mean and standard deviation.Key words: morphology, morphometry, mandible, roe deer, shee

  2. Esophageal morphometric and biomechanical changes during aging in rats

    DEFF Research Database (Denmark)

    Zhao, Jingbo; Gregersen, Hans

    of the present study is to investigate the esophageal geometry and biomechanical changes during aging in rats. Materials and methods Twenty-four male Wistar rats, aged from 6 to 22 months, were used in the study. The body weight and the wet weight per length of esophageal segment were measured at the termination...... was found among 12, 18 and 22 months groups (p>0.05). The longitudinal stress-strain curves shifted from right to the left during aging (pstiffness has no obvious...... change after 12 months in the circumferential direction. Furthermore, we confirm that the esophagus was stiffer in the longitudinal direction than in the circumferential direction. Conclusions A pronounced morphometric and biomechanical remodeling was occurred in the rat esophagus during aging...

  3. Hepatic alveolar echinococcosis: correlative US and CT study

    International Nuclear Information System (INIS)

    Didier, D.; Weiler, S.; Rohmer, P.; Lasseque, A.; Deschamps, J.P.; Vuitton, D.; Miguet, J.P.; Weill, F.

    1985-01-01

    A total of 24 cases of hepatic alveolar echinococcosis (HAE) due to Echinococcus multilocularis was assessed by US and CT. The diagnosis was confirmed in all cases by immunologic and histologic study. Both US and CT patterns of HAE showed changes of liver morphology in both contour and size. Abnormal areas of parenchyma were nodular or in fields, irregular, heterogeneous, and basically echogenic. Clustered microcalcifications were encountered within the abnormal parenchymal fields in 50% of cases, and necrotized zones occurred in 40% of cases. Dilatation of intrahepatic bile ducts was commonly seen, especially on US; hilar involvement was frequent. Follow-up by both techniques can display increases of primary lesions, occurrence of new foci, and local or regional extensions. Precise evaluations of the lesions arising from correlative use of US and CT permits adequate therapeutic management

  4. Hepatic alveolar echinococcosis: correlative US and CT study

    Energy Technology Data Exchange (ETDEWEB)

    Didier, D.; Weiler, S.; Rohmer, P.; Lasseque, A.; Deschamps, J.P.; Vuitton, D.; Miguet, J.P.; Weill, F.

    1985-01-01

    A total of 24 cases of hepatic alveolar echinococcosis (HAE) due to Echinococcus multilocularis was assessed by US and CT. The diagnosis was confirmed in all cases by immunologic and histologic study. Both US and CT patterns of HAE showed changes of liver morphology in both contour and size. Abnormal areas of parenchyma were nodular or in fields, irregular, heterogeneous, and basically echogenic. Clustered microcalcifications were encountered within the abnormal parenchymal fields in 50% of cases, and necrotized zones occurred in 40% of cases. Dilatation of intrahepatic bile ducts was commonly seen, especially on US; hilar involvement was frequent. Follow-up by both techniques can display increases of primary lesions, occurrence of new foci, and local or regional extensions. Precise evaluations of the lesions arising from correlative use of US and CT permits adequate therapeutic management.

  5. Morphometric variations in gametocytes of Hepatozoon canis from naturally infected dogs.

    Science.gov (United States)

    Eljadar, Mohamed S M; Singla, L D; Mustafa, Radya A A; Uppal, S K

    2013-04-01

    This study presents the morphometric characteristic of canine haemoprotozoan, Hepatozoon canis, using software DP2-BSW (OLYMPUS). The gametocytes of H. canis found inside the neutrophils were characteristic in shape and size and varied from 9.50 to 11.80 μm × 5.10-6.00 μm. Parasitaemia ranged from 1.00 to 39.00 %. Few gametocytes without nuclei and of abnormal shapes were also observed. The results were compared with the measurements done by using ocular micrometer.

  6. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  7. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  8. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  9. Morphometric analysis with open source software to explore shallow hydrogeological features in Senegal and Guinea

    Science.gov (United States)

    Fussi, Fabio; Di Leo, Margherita; Bonomi, Tullia; Di Mauro, Biagio; Fava, Francesco; Fumagalli, Letizia; Hamidou Kane, Cheikh; Faye, Gayane; Niang, Magatte; Wade, Souleye; Hamidou, Barry; Colombo, Roberto

    2015-04-01

    Water represents a vital resource for everyone on this Planet, but, for some populations, the access to potable water is not given for granted. Recently, the interest in low cost technical solutions to improve access to ground water in developing countries, especially for people located in remote areas, has increased. Manual drilling (techniques to drill boreholes for water using human or animal power) is well known and practiced for centuries in many countries and represents a valid alternative to increase water access. Lately, this practice has raised the attention of national governments and international organizations. This technique is applicable only where hydrogeological conditions are suitable, namely in presence of thick layers of unconsolidated sediments and a shallow water table Aim of this study is exploring the potential of morphometric analysis to improve the methodology to identify areas with suitable hydrogeological conditions for manual drilling, supporting the implementation of water supply programs that can have great impact on living condition of the population. The characteristics of shallow geological layers are strongly dependent from geomorphological processes and are usually reflected in the morphological characteristics of landforms. Under these hypotheses, we have been investigating the geo-statistical correlation between several morphometric variables and a set of hydrogeological variables used in the estimation of suitability for manual drilling: thickness of unconsolidated sediments, texture, hydraulic conductivity of shallow aquifer, depth of water table. The morphology of two study areas with different landscape characteristics in Guinea and Senegal has been investigated coupling the Free and Open Source Software GRASS GIS and R. Several morphometric parameters have been extracted from ASTER GDEM digital elevation model, and have been compared with a set of hydrogeological characteristics obtained from semi-automatic analysis of

  10. Study of CT and etiology In 11B cases of eoute headache without hemlplegla

    Institute of Scientific and Technical Information of China (English)

    Daoming Tong

    2000-01-01

    objectal To study the relation between CT and etiology of acute headache without hemiplegia. Methods 118 cases of acute headache without hemiplegia were studied with CT scan. The patients with normal CT were diagnosed with lumbar punc -tura or diagnostic standard for establishing disease. Results The first three etiologies were cerebrovescular disease (65 cases, 55%), migraine (25 cases, 21%), meningitis and encephalitis (19 cases, 155. 9%). 53% of patients with subarachnoid hemorrhage(SAH) was diagnosed in CT unnormal group, and 12.4% of patients with Sall was showed by lumbar puncture in CT normal group(P<0. 001). CT was normal in 18% of patients with a definite SAH(7/39). The positive rates of intracranial infection in CT normal group(by lumbar puncture) was reearkably higher than in CT unnormal group (18/58 versus 2/60, p<0.005), Conolusion CT is more sensitive to intracranial hemorrhage, tumor and infarction. SAH of a negative Ctscan is not rare. CT is far inferior to lumbar puncture in meningitis or encephalitis.

  11. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  12. Entamoeba Clone-Recognition Experiments: Morphometrics, Aggregative Behavior, and Cell-Signaling Characterization.

    Science.gov (United States)

    Espinosa, Avelina; Paz-Y-Miño-C, Guillermo; Hackey, Meagan; Rutherford, Scott

    2016-05-01

    Studies on clone- and kin-discrimination in protists have proliferated during the past decade. We report clone-recognition experiments in seven Entamoeba lineages (E. invadens IP-1, E. invadens VK-1:NS, E. terrapinae, E. moshkovskii Laredo, E. moshkovskii Snake, E. histolytica HM-1:IMSS and E. dispar). First, we characterized morphometrically each clone (length, width, and cell-surface area) and documented how they differed statistically from one another (as per single-variable or canonical-discriminant analyses). Second, we demonstrated that amebas themselves could discriminate self (clone) from different (themselves vs. other clones). In mix-cell-line cultures between closely-related (E. invadens IP-1 vs. E. invadens VK-1:NS) or distant-phylogenetic clones (E. terrapinae vs. E. moshkovskii Laredo), amebas consistently aggregated with same-clone members. Third, we identified six putative cell-signals secreted by the amebas (RasGap/Ankyrin, coronin-WD40, actin, protein kinases, heat shock 70, and ubiquitin) and which known functions in Entamoeba spp. included: cell proliferation, cell adhesion, cell movement, and stress-induced encystation. To our knowledge, this is the first multi-clone characterization of Entamoeba spp. morphometrics, aggregative behavior, and cell-signaling secretion in the context of clone-recognition. Protists allow us to study cell-cell recognition from ecological and evolutionary perspectives. Modern protistan lineages can be central to studies about the origins and evolution of multicellularity. © 2016 The Author(s) Journal of Eukaryotic Microbiology © 2016 International Society of Protistologists.

  13. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Honda, Eiichi; Tetsumura, Akemi; Kurabayashi, Tohru

    2011-01-01

    Purpose: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases. Materials and methods: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom. Results: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64x) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64. Conclusions: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases.

  14. Using geometric morphometric visualizations of directional selection gradients to investigate morphological differentiation.

    Science.gov (United States)

    Weaver, Timothy D; Gunz, Philipp

    2018-04-01

    Researchers studying extant and extinct taxa are often interested in identifying the evolutionary processes that have lead to the morphological differences among the taxa. Ideally, one could distinguish the influences of neutral evolutionary processes (genetic drift, mutation) from natural selection, and in situations for which selection is implicated, identify the targets of selection. The directional selection gradient is an effective tool for investigating evolutionary process, because it can relate form (size and shape) differences between taxa to the variation and covariation found within taxa. However, although most modern morphometric analyses use the tools of geometric morphometrics (GM) to analyze landmark data, to date, selection gradients have mainly been calculated from linear measurements. To address this methodological gap, here we present a GM approach for visualizing and comparing between-taxon selection gradients with each other, associated difference vectors, and "selection" gradients from neutral simulations. To exemplify our approach, we use a dataset of 347 three-dimensional landmarks and semilandmarks recorded on the crania of 260 primate specimens (112 humans, 67 common chimpanzees, 36 bonobos, 45 gorillas). Results on this example dataset show how incorporating geometric information can provide important insights into the evolution of the human braincase, and serve to demonstrate the utility of our approach for understanding morphological evolution. © 2018 The Author(s). Evolution © 2018 The Society for the Study of Evolution.

  15. Accurate localization of intracavitary brachytherapy applicators from 3D CT imaging studies

    International Nuclear Information System (INIS)

    Lerma, F.A.; Williamson, J.F.

    2002-01-01

    Purpose: To present an accurate method to identify the positions and orientations of intracavitary (ICT) brachytherapy applicators imaged in 3D CT scans, in support of Monte Carlo photon-transport simulations, enabling accurate dose modeling in the presence of applicator shielding and interapplicator attenuation. Materials and methods: The method consists of finding the transformation that maximizes the coincidence between the known 3D shapes of each applicator component (colpostats and tandem) with the volume defined by contours of the corresponding surface on each CT slice. We use this technique to localize Fletcher-Suit CT-compatible applicators for three cervix cancer patients using post-implant CT examinations (3 mm slice thickness and separation). Dose distributions in 1-to-1 registration with the underlying CT anatomy are derived from 3D Monte Carlo photon-transport simulations incorporating each applicator's internal geometry (source encapsulation, high-density shields, and applicator body) oriented in relation to the dose matrix according to the measured localization transformations. The precision and accuracy of our localization method are assessed using CT scans, in which the positions and orientations of dense rods and spheres (in a precision-machined phantom) were measured at various orientations relative to the gantry. Results: Using this method, we register 3D Monte Carlo dose calculations directly onto post insertion patient CT studies. Using CT studies of a precisely machined phantom, the absolute accuracy of the method was found to be ±0.2 mm in plane, and ±0.3 mm in the axial direction while its precision was ±0.2 mm in plane, and ±0.2 mm axially. Conclusion: We have developed a novel, and accurate technique to localize intracavitary brachytherapy applicators in 3D CT imaging studies, which supports 3D dose planning involving detailed 3D Monte Carlo dose calculations, modeling source positions, shielding and interapplicator shielding

  16. Anatomic study of celiac ganglia using CT in cadavers

    International Nuclear Information System (INIS)

    Zhao Qionghui; Zhang Xiaoming; Zeng Nanlin; Cai Changping; Xie Xingguo; Li Chengjun

    2005-01-01

    Objective: To identify the celiac ganglia in cadavers by using current CT techniques, and to facilitate its identification in vivo by CT. Methods: Fifty cadavers were dissected, moving peritoneal organs such as liver and stomach to expose the celiac ganglia. The location, morphology, and dimensions of celiac ganglia, and their relationship to abutting structures, were noted. The celiac ganglia in 6 of the 50 cadavers without peripancreatic diseases and with clear anatomy were isolated and marked with yellow dye and Iohexol injection. In these 6 cadavers, the moved organs were relocated, the abdomen was closed, and CT was performed. CT derived measurements of celiac ganglia were compared with those from cadavers study. Results: The celiac ganglia of 47 of 50 cadavers (94%) were located between T12-L1, and those of 3 cadavers (6%) were located between T11-12. The superior-inferior diameter of the right ganglia was (25.01 ±6.09) mm, long (left-right) diameter was (13.18 ± 3.62) mm, and short (thickness) diameter was (1.40 ± 0.55) mm. In the left ganglia, these three diameters were (22.74 ± 5.70) mm, (15.07 ± 4.35) mm, and (2.00 ± 0.71 ) mm, respectively. On the CT images of 6 cadavers, the right and left ganglia were all identified and were hyperdense relative to viscus, such as liver and spleen. The long and short diameters on CT images were (15.20 ± 1.64) mm and (1.53 ± 0.52) mm for the right ganglia and (16.25 ± 1.73 ) mm and (2.20 ± 0.73) mm for the left ganglia. There was no significant difference between the diameters of the ganglia measured on CT images and by dissection (P>0.05). Conclusion: Current CT techniques can demonstrate accurately the celiac ganglia in cadavers. This can be a reference for identifying the celiac plexus in vivo. (authors)

  17. Comparative morphometrics of two populations of Mugil curema (Pisces: Mugilidae on the Atlantic and Mexican Pacific coasts

    Directory of Open Access Journals (Sweden)

    Ana Laura Ibáñez-Aguirre

    2006-03-01

    Full Text Available A population of Mugil curema in the Gulf of Mexico was compared with one in the Pacific Ocean using nine morphometric variables. The allometries of each measurement were estimated in relation to total length. Morphometric variations were analyzed using the normalization of the individuals of each group and two multivariate methods: correspondence analysis, used to explore the information, and discriminant analysis. Results indicated that the diameter of the eye differentiated the populations of both coasts, the Atlantic population showed a larger eye diameter. However, other than this and the body width (which can be strongly influenced by sexual maturation there was no difference between the shapes of both populations. We discuss the larger morphometric variability of the Atlantic population which may be due to the presence of more than one population unlike the Pacific population.

  18. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    Science.gov (United States)

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  19. Morphometric Relationship, Growth, and Condition Factor of Flyingfish, Hirundicththys oxycephalus during spawning season

    Science.gov (United States)

    Tuapetel, Friesland; Nessa, Natsir; Alam Ali, Syamsu; Sudirman; Hutubessy, B. G.; Mosse, J. W.

    2017-10-01

    Flyingfish, Hirundichthys oxycephalus together with its congener species has become a major artisanal fishery resource from the Seram Sea, an area between Seram and Papua Island. However, biological information about this species has been poorly documented. Our current study focused on the growth and morphometric relationships of spawning cohorts during spawning season (June to October 2013). Flyingfish which were trapped in bale-bale, an egg aggregation device for flying fish, were collected offshore of the Southeastern Seram Sea. Total samples of 1693 with Fork Length (FL) ranged from 156.15mm to 245.52mm and total weight from 53.15gr to 115.45gr. Von Bertalanffy growth functions (L∞) for-pooled sexes were FL = 251mm [1-e (1.82 (t+0.060)], K=1.82 and t0 = 0.060. Morphometrically, significant differences were observed for all individuals between sexes (F=14.20, P=0.0002), sampling locations (F=88.48 Pfish generally declined in July-August. During spawning season, this fish tended to form single spawning cohort. The results of this study provide a significant understanding of the life history of this valuable fish inhabiting this particular region that rarely receives scientific investigation. For management purposes, harvesting eggs including broodstocks will lead to critical population depletion.

  20. The Inappropriate Symmetries of Multivariate Statistical Analysis in Geometric Morphometrics.

    Science.gov (United States)

    Bookstein, Fred L

    In today's geometric morphometrics the commonest multivariate statistical procedures, such as principal component analysis or regressions of Procrustes shape coordinates on Centroid Size, embody a tacit roster of symmetries -axioms concerning the homogeneity of the multiple spatial domains or descriptor vectors involved-that do not correspond to actual biological fact. These techniques are hence inappropriate for any application regarding which we have a-priori biological knowledge to the contrary (e.g., genetic/morphogenetic processes common to multiple landmarks, the range of normal in anatomy atlases, the consequences of growth or function for form). But nearly every morphometric investigation is motivated by prior insights of this sort. We therefore need new tools that explicitly incorporate these elements of knowledge, should they be quantitative, to break the symmetries of the classic morphometric approaches. Some of these are already available in our literature but deserve to be known more widely: deflated (spatially adaptive) reference distributions of Procrustes coordinates, Sewall Wright's century-old variant of factor analysis, the geometric algebra of importing explicit biomechanical formulas into Procrustes space. Other methods, not yet fully formulated, might involve parameterized models for strain in idealized forms under load, principled approaches to the separation of functional from Brownian aspects of shape variation over time, and, in general, a better understanding of how the formalism of landmarks interacts with the many other approaches to quantification of anatomy. To more powerfully organize inferences from the high-dimensional measurements that characterize so much of today's organismal biology, tomorrow's toolkit must rely neither on principal component analysis nor on the Procrustes distance formula, but instead on sound prior biological knowledge as expressed in formulas whose coefficients are not all the same. I describe the problems

  1. Gross and morphometric anatomical changes of the thyroid gland in ...

    African Journals Online (AJOL)

    Gross and morphometric anatomical changes of the thyroid gland in the West African Dwarf Goat ( Capra hircus ) during the foetal and post-natal periods of development. ... The right lobe was more cranially located on the larynx and trachea than the left lobe in all age groups. Thyroid isthmus was absent in few foetal thyroid ...

  2. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  3. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  4. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  5. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  6. Morphometric analysis of the fascicular organisation of the optic nerve

    Directory of Open Access Journals (Sweden)

    Radunović Miroslav

    2015-01-01

    Full Text Available Background/Aim. The optic nerve is anatomically observed in four segments: intrabulbar, orbital, canalicular, and cranial. According to the literature, the surface of the transversal cut of the nerve is different through it. The aim of this study was to evaluate the fascicular organisation of the optic nerve, throughout its three segments from the eye. Methods. Five pairs of optic nerves, obtained from the autopsies were examined. Using Heidenhain's (azan staining, the cuts were prepared for microscopy. Morphometric analysis was performed using the stereological methods for morphometric cytology - the Weible’s testing system M42. The following measures were established: the surface of the transverse cut of the nerve, the entire surface of fasciculi, the entire surface of connective tissue and blood vessels, the number of fasciculi, the surface of a single fasciculus. Results. The surface of the transverse cut of the nerve was found to grow from the orbital to the cranial segment, as well as the entire surface of fasciculi. While their number is significantly lower in the cranial segment, the number of fasciculi varied slightly between the orbital and the canalicular segment. The surface of a single fasciculus grows from the bulb to the chiasma. There is probable a cause to believe that this may be due to fusion of the “small” fasciculi in the orbitocranial direction. Conclusion. There are significant differences among the examined parameters of the different parts of the optic nerve.

  7. Normal sacroiliac joint: a CT study of asymptomatic patients

    International Nuclear Information System (INIS)

    Vogler, J.B. III; Brown, W.H.; Helms, C.A.; Genant, H.K.

    1984-01-01

    The sacroiliac (SI) joints of 45 asymptomatic subjects were prospectively studied to define better the normal appearance of SI joints on CT scans and therby attach appropriate significance to CT signs of sacroiliitis. Joint space narrowing, subchondral sclerosis, erosions, ankylosis, osteophytes, subchondral cysts, and symmetry were evaluted. The results indicate that the SI joints demonstrate symmetry in patients under the age of 30 (100% of subjects in this age group). Those CT findings of sacroiliitis that occurred infrequently in the asymptomatic population, and hence may represent good indicators of sacroiliac disease, include increased sacral subchondral sclerosis in subjects under the age of 40 (11%), bilateral or unilateral uniform joint space of less than 2 mm (2% or 0%, respectively), erosions (2%), and intraarticular ankylosis (0%)

  8. Neck after total laryngectomy: CT study

    International Nuclear Information System (INIS)

    DiSantis, D.J.; Balfe, D.M.; Hayden, R.E.; Sagel, S.S.; Sessions, D.; Lee, J.K.T.

    1984-01-01

    Computed tomographic scans in 23 patients who had undergone total laryngectomy were analyzed retrospectively to determine normal postoperative appearance and to evaluate the role of CT in assessing recurrent neoplasm. Nine patients without clinical evidence of recurrence illustrated the normal postoperative changes: a round or ovoid neopharynx connecting the base of the tongue with the cervical esophagus and intact fat planes surrounding the neopharynx, neurovascular bundles, and sternocleidomastoid muscles. In the 12 patients with recurrent neoplasm, the CT manifestations included masses involving the internal jugular lymph node chain, tracheostomy site, or paratracheal region. CT supplemented physical examination and indirect mirror examination, providing data regarding presence and extent of recurrent tumor and aiding in planning the mode and scope of therapy

  9. Parametric modeling of the intervertebral disc space in 3D: application to CT images of the lumbar spine.

    Science.gov (United States)

    Korez, Robert; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-10-01

    Gradual degeneration of intervertebral discs of the lumbar spine is one of the most common causes of low back pain. Although conservative treatment for low back pain may provide relief to most individuals, surgical intervention may be required for individuals with significant continuing symptoms, which is usually performed by replacing the degenerated intervertebral disc with an artificial implant. For designing implants with good bone contact and continuous force distribution, the morphology of the intervertebral disc space and vertebral body endplates is of considerable importance. In this study, we propose a method for parametric modeling of the intervertebral disc space in three dimensions (3D) and show its application to computed tomography (CT) images of the lumbar spine. The initial 3D model of the intervertebral disc space is generated according to the superquadric approach and therefore represented by a truncated elliptical cone, which is initialized by parameters obtained from 3D models of adjacent vertebral bodies. In an optimization procedure, the 3D model of the intervertebral disc space is incrementally deformed by adding parameters that provide a more detailed morphometric description of the observed shape, and aligned to the observed intervertebral disc space in the 3D image. By applying the proposed method to CT images of 20 lumbar spines, the shape and pose of each of the 100 intervertebral disc spaces were represented by a 3D parametric model. The resulting mean (±standard deviation) accuracy of modeling was 1.06±0.98mm in terms of radial Euclidean distance against manually defined ground truth points, with the corresponding success rate of 93% (i.e. 93 out of 100 intervertebral disc spaces were modeled successfully). As the resulting 3D models provide a description of the shape of intervertebral disc spaces in a complete parametric form, morphometric analysis was straightforwardly enabled and allowed the computation of the corresponding

  10. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  11. Morphometric analysis of peroxisome proliferation by phthalate esters in rat liver

    NARCIS (Netherlands)

    Dormans JAMA; Jansen EHJM; de Vlugt-van den Koedijk FM; Riool-Nesselaar G

    1992-01-01

    Morphometric analysis was performed on liver sections of rats at light (LM) and electron microscopical (EM) level to demonstrate proliferation of peroxisomes after administration of di (2-ethylhexyl)phthalate at dietary levels of 0, 60, 200, 600, 2000 and 6000 mg/kg diet for 2 weeks. Enzyme

  12. Study of CT image texture using deep learning techniques

    Science.gov (United States)

    Dutta, Sandeep; Fan, Jiahua; Chevalier, David

    2018-03-01

    For CT imaging, reduction of radiation dose while improving or maintaining image quality (IQ) is currently a very active research and development topic. Iterative Reconstruction (IR) approaches have been suggested to be able to offer better IQ to dose ratio compared to the conventional Filtered Back Projection (FBP) reconstruction. However, it has been widely reported that often CT image texture from IR is different compared to that from FBP. Researchers have proposed different figure of metrics to quantitate the texture from different reconstruction methods. But there is still a lack of practical and robust method in the field for texture description. This work applied deep learning method for CT image texture study. Multiple dose scans of a 20cm diameter cylindrical water phantom was performed on Revolution CT scanner (GE Healthcare, Waukesha) and the images were reconstructed with FBP and four different IR reconstruction settings. The training images generated were randomly allotted (80:20) to a training and validation set. An independent test set of 256-512 images/class were collected with the same scan and reconstruction settings. Multiple deep learning (DL) networks with Convolution, RELU activation, max-pooling, fully-connected, global average pooling and softmax activation layers were investigated. Impact of different image patch size for training was investigated. Original pixel data as well as normalized image data were evaluated. DL models were reliably able to classify CT image texture with accuracy up to 99%. Results show that the deep learning techniques suggest that CT IR techniques may help lower the radiation dose compared to FBP.

  13. Hydrological inferences through morphometric analysis of lower Kosi river basin of India for water resource management based on remote sensing data

    Science.gov (United States)

    Rai, Praveen Kumar; Chandel, Rajeev Singh; Mishra, Varun Narayan; Singh, Prafull

    2018-03-01

    Satellite based remote sensing technology has proven to be an effectual tool in analysis of drainage networks, study of surface morphological features and their correlation with groundwater management prospect at basin level. The present study highlights the effectiveness and advantage of remote sensing and GIS-based analysis for quantitative and qualitative assessment of flood plain region of lower Kosi river basin based on morphometric analysis. In this study, ASTER DEM is used to extract the vital hydrological parameters of lower Kosi river basin in ARC GIS software. Morphometric parameters, e.g., stream order, stream length, bifurcation ratio, drainage density, drainage frequency, drainage texture, form factor, circularity ratio, elongation ratio, etc., have been calculated for the Kosi basin and their hydrological inferences were discussed. Most of the morphometric parameters such as bifurcation ratio, drainage density, drainage frequency, drainage texture concluded that basin has good prospect for water management program for various purposes and also generated data base that can provide scientific information for site selection of water-harvesting structures and flood management activities in the basin. Land use land cover (LULC) of the basin were also prepared from Landsat data of 2005, 2010 and 2015 to assess the change in dynamic of the basin and these layers are very noteworthy for further watershed prioritization.

  14. A geometric morphometric study of a Middle Pleistocene cranium from Hexian, China.

    Science.gov (United States)

    Cui, Yaming; Wu, Xinzhi

    2015-11-01

    The Hexian calvarium is one of the most complete and well-preserved Homo erectus fossils ever found in east Asia, apart from the Zhoukoudian specimens. Various methods bracket the age of the Hexian fossil to between 150 and 412 ka (thousands of years ago). The Hexian calvarium has been considered to be H. erectus given its morphological similarities to Zhoukoudian and Javan H. erectus. However, discussion continues regarding the affinities of the Hexian specimen with other H. erectus fossils. The arguments mainly focus on its relationships to other Asian H. erectus fossils, including those from both China and Java. To better determine the affinities of the Hexian cranium, our study used 3D landmark and semilandmark geometric morphometric techniques and multivariate statistical analyses to quantify the shape of the neurocranium and to compare the Hexian cranium to other H. erectus specimens. The results of this study confirmed the morphological similarities between Hexian and Chinese H. erectus in overall morphology, and particularly in the structure of the frontal bone and the posterior part of the neurocranium. Although the Hexian specimen shows the strongest connection to Chinese H. erectus, the morphology of the lateral neurocranium resembles early Indonesian H. erectus specimens, possibly suggesting shared common ancestry or gene flow from early Indonesian populations. Overall cranial and frontal bone morphology are strongly influenced by geography. Although geographically intermediate between Zhoukoudian and Indonesian H. erectus, the Hexian specimen does not form part of an obvious morphological gradient with regard to overall cranial shape. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Morphometric comparison of pumpkinseed (Centrarchidae populations in Poland

    Directory of Open Access Journals (Sweden)

    Grzegorz Zięba

    2015-11-01

    Full Text Available The pattern of morphometric differentiation between two populations of pumpkinseed (Lepomis gibbosus inhabiting distinctively different habitats in north-west Poland was examined. Fish were collected at sites that differ in water temperature and hydrology – an ambient temperature, urban pond vs an artificially-heated drainage channel, respectively. In principal component analysis, the first and second components, which accounted for 40% and 11 %, respectively, of the variability between the habitat types, revealed that the observed differences were related to head and body dimensions, with specimens from the heated site having generally larger heads, higher bodies, and longer anterior components. Larger body size is normally associated with greater survival in unnatural and highly variable environments. This study was funded by the National Science Centre, Poland (decision No DEC-2011/01/D/NZ8/01807.

  16. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  17. MicroCT Analysis of Micro-Nano Titanium Implant Surface on the Osseointegration.

    Science.gov (United States)

    Ban, Jaesam; Kang, Seongsoo; Kim, Jihyun; Lee, Kwangmin; Hyunpil, Lim; Vang, Mongsook; Yang, Hongso; Oh, Gyejeong; Kim, Hyunseung; Hwang, Gabwoon; Jung, Yongho; Lee, Kyungku; Park, Sangwon; Yunl, Kwidug

    2015-01-01

    This study was to investigate the effects of micro-nano titanium implant surface on the osseointegration. A total of 36 screw-shaped implants were used. The implant surfaces were classified into 3 groups (n = 12): machined surface (M group), nanosurface which is nanotube formation on the machined surface (MA group) and nano-micro surface which is nanotube formation on the RBM surface (RA group). Anodic oxidation was performed at a 20 V for 10 min with 1 M H3PO4 and 1.5 wt% HF solutions. The implants were installed on the humerus on 6 beagles. After 4 and 12 weeks, the morphometric analysis with micro CT (skyscan 1172, SKYSCAN, Antwerpen, Belgium) was done. The data were statistically analyzed with two-way ANOVA. Bone mineral density and bone volume were significantly increased depending on time. RA group showed the highest bone mineral density and bone volume at 4 weeks and 12 weeks significantly. It indicated that nano-micro titanium implant surface showed faster and more mature osseointegration.

  18. CT studies of brain abscesses in cats

    International Nuclear Information System (INIS)

    Kretzschmar, K.; Wallenfang, T.; Bohl, J.

    1981-01-01

    Cerebral abscesses were produced in 56 cats by introducing staphylococcus aureus into the white matter of one cerebral hemisphere, using a stereotaxic apparatus. The cats were treated with antibiotics and/or steroids. The size and density of the inflammatory process and the abscess ring were measured on postcontrast CT scans. Differences were found depending on the stage of the abscess, but the deviation of values was too great for determining the age of the abscess from one measurement, to be able to apply proper treatment. The size and density of the abscesses were the same on CT whether the animals were treated or not. This was contrary to the clinical picture, the measurements of edema, and the histopathological studies. (orig.)

  19. Study on the brain CT scan of SLE patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S; Narita, M; Katoh, K; Matsunaga, K; Ishigatsubo, Y [Yokohama City Univ. (Japan). Faculty of Medicine

    1982-03-01

    Cranial CT scanning revealed abnormality in 12 of 25 patients with SLE (48%). Ventricular sulcal enlargement was found mostly in younger patients between 16 and 36 years, an average of 25 years. Abnormality in electroencephalogram, principally paroxysmal abnormality, was found in 8 of 13 cases (62%) of normal CT findings. Non-paroxysmal slow-wave abnormality was observed in 9 of 12 abnormal CT cases. Of 13 patients with CNS symptoms, 8 had abnormal CT findings, and 5 had only mental disorder with normal CT findings. In 12 patients without neuropsychiatric involvement, 4 (33%) had abnormal CT findings. The rate of abnormal CT findings was increased in the patients receiving a high dosage of a steroid agent. Five of 6 patients who showed ventricular sulcal enlargement had been given prednisolone in a dosage of 35 mg or more per day.

  20. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  1. Body and skull morphometric variations between two shovel-headed species of Amphisbaenia (Reptilia: Squamata with morphofunctional inferences on burrowing

    Directory of Open Access Journals (Sweden)

    Leandro dos Santos Lima Hohl

    2017-07-01

    Full Text Available Background Morphological descriptions comparing Leposternon microcephalum and L. scutigerum have been made previously. However, these taxa lack a formal quantitative morphological characterization, and comparative studies suggest that morphology and burrowing performance are be related. The excavatory movements of L. microcephalum have been described in detail. However, there is a lack of studies comparing locomotor patterns and/or performance among different amphisbaenids sharing the same skull shape. This paper presents the first study of comparative morphometric variations between two closely related amphisbaenid species, L. microcephalum and L. scutigerum, with functional inferences on fossorial locomotion efficiency. Methods Inter-specific morphometric variations were verified through statistical analyses of body and cranial measures of L. microcephalum and L. scutigerum specimens. Their burrowing activity was assessed through X-ray videofluoroscopy and then compared. The influence of morphological variation on the speed of digging was tested among Leposternon individuals. Results Leposternon microcephalum and L. scutigerum are morphometrically distinct species. The first is shorter and robust with a wider head while the other is more elongated and slim with a narrower head. They share the same excavatory movements. The animals analyzed reached relatively high speeds, but individuals with narrower skulls dug faster. A negative correlation between the speed and the width of skull was determined, but not with total length or diameter of the body. Discussion The morphometric differences between L. microcephalum and L. scutigerum are in accord with morphological variations previously described. Since these species performed the same excavation pattern, we may infer that closely related amphisbaenids with the same skull type would exhibit the same excavatory pattern. The negative correlation between head width and excavation speed is also

  2. Comparison of Ct and MRI in the study of the pituitary gland

    International Nuclear Information System (INIS)

    Juliani, G.; Avataneo, T.; Potenzoni, F.; Sorrentino, T

    1989-01-01

    Normal CT and MR anatomy was studied in two series (53 and 25 cases respectively) of young volunteers of both sexes, asymptomatic and certainly without lesions of the pituitary gland. 115 other pathological cases (73 hyperprolactinemias, 8 acromegalies, 15 Cushing syndromes, 2 hyperthyroidisms, 17 non-secreting adenomas) were examined using both CT and MRI. Both an accurate review of the relative literature and the results of our own series prove that MR is superior to CT in diagnosing pituitary microadenomas (3.2% not diagnosed with MRI and 25.8% not diagnosed with CT), in the follow-up of prolactinomas subjected to medical therapy and in the study of extrasellar involvement of pituitery adenomas, particularly with regard to the demonstration of compression of the optic chiasma

  3. [Study of patients with prolonged fever with (18)F-FDG PET/CT].

    Science.gov (United States)

    Moragas, M; Cozar, M Puig; Buxeda, M; Soler, M; Riera, E; García, J R

    2015-01-01

    To review the findings on (18)F-FDG PET-CT in patients with fever of unknown origin lasting more than 7 days. This retrospective descriptive observational study included 93 (18)F-FDG PET-CT studies to detect a fever-causing focus done at three nuclear medicine centers from October 2006 through February 2014. A nuclear medicine specialist and a radiologist reviewed the images for foci of pathological uptake; another specialist's opinion resolved discrepancies. The findings on (18)F-FDG PET-CT studies were checked against clinical and/or histological findings. Abnormal (18)F-FDG uptake on PET-CT that could explain the cause of the fever was found in 52 (56%) of the 93 studies, and the cause of the fever was confirmed in 50 of these 52 studies. In the 50 cases in which the cause of the fever was confirmed, infection was the most common cause (54%), followed by noninfectious inflammatory disease (28%) and tumors (18%). (18)F-FDG PET-CT is useful in diagnosing the cause of prolonged febrile illness, so it might be practical to use it earlier in the diagnostic process. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  4. A morphometric study on regeneration of the human liver following hepatectomy by computed tomography

    International Nuclear Information System (INIS)

    Okamoto, Eizo; Yamanaka, Naoki

    1983-01-01

    A morphometric study has been carried out on the restoration of remnant hepatic volume (RHV) after various extent of hepatectomy in humans by serial computed tomography in 15 non-cirrhotics, 14 cirrhotics and 7 hepatic failures. Restoration of RHV has been observed only in patients with more than 10 % hepatectomy. In non-cirrhotics with major hepatectomy (RHV less than 600 cm 3 ), an early rapid increasing phase was followed by a subsequent decreasing phase and then a slow increasing phase. Decreasing phase was absent in most non-cirrhotics with moderate hepatectomy (RHV 600-1000 cm 3 ) and cirrhotics. Daily increase rate of RHV during the first posthepatectomy month was inversely proportional to the RHV at operation restoring invariably to 800-900 cm 3 at the end of this month. Termination of regeneration was within 6 months in non-cirrhotics with moderate hepatectomy and from 6 to 12 months in those with major hepatectomy. It was delayed in cirrhotics. RHV has finally attained to an average of 90 % of preoperative hepatic volume in non-cirrhotics and 81 % in cirrhotics. The restoration of RHV was extremely poor in hepatic failures. (author)

  5. East Greenland and Barents Sea polar bears (Ursus maritimus): adaptive variation between two populations using skull morphometrics as an indicator of environmental and genetic differences.

    Science.gov (United States)

    Pertoldi, Cino; Sonne, Christian; Wiig, Øystein; Baagøe, Hans J; Loeschcke, Volker; Bechshøft, Thea Østergaard

    2012-06-01

    A morphometric study was conducted on four skull traits of 37 male and 18 female adult East Greenland polar bears (Ursus maritimus) collected 1892-1968, and on 54 male and 44 female adult Barents Sea polar bears collected 1950-1969. The aim was to compare differences in size and shape of the bear skulls using a multivariate approach, characterizing the variation between the two populations using morphometric traits as an indicator of environmental and genetic differences. Mixture analysis testing for geographic differentiation within each population revealed three clusters for Barents Sea males and three clusters for Barents Sea females. East Greenland consisted of one female and one male cluster. A principal component analysis (PCA) conducted on the clusters defined by the mixture analysis, showed that East Greenland and Barents Sea polar bear populations overlapped to a large degree, especially with regards to females. Multivariate analyses of variance (MANOVA) showed no significant differences in morphometric means between the two populations, but differences were detected between clusters from each respective geographic locality. To estimate the importance of genetics and environment in the morphometric differences between the bears, a PCA was performed on the covariance matrix derived from the skull measurements. Skull trait size (PC1) explained approx. 80% of the morphometric variation, whereas shape (PC2) defined approx. 15%, indicating some genetic differentiation. Hence, both environmental and genetic factors seem to have contributed to the observed skull differences between the two populations. Overall, results indicate that many Barents Sea polar bears are morphometrically similar to the East Greenland ones, suggesting an exchange of individuals between the two populations. Furthermore, a subpopulation structure in the Barents Sea population was also indicated from the present analyses, which should be considered with regards to future management

  6. Genetic evidence and new morphometric data as essential tools to identify the Patagonian seahorse Hippocampus patagonicus (Pisces, Syngnathidae).

    Science.gov (United States)

    González, R; Dinghi, P; Corio, C; Medina, A; Maggioni, M; Storero, L; Gosztonyi, A

    2014-02-01

    A genetic study to support morphometric analyses was used to improve the description and validate the Patagonian seahorse Hippocampus patagonicus (Syngnathidae) on the basis of a large number of specimens collected in the type locality (San Antonio Bay, Patagonia, Argentina). DNA sequence data (from the cytochrome b region of the mitochondrial genome) were used to differentiate this species from its relatives cited for the west Atlantic Ocean. Both phylogenetic and genetic distance analyses supported the hypothesis that H. patagonicus is a species clearly differentiated from others, in agreement with morphometric studies. Hippocampus patagonicus can be distinguished from Hippocampus erectus by the combination of the following morphometric characteristics: (1) in both sexes and all sizes of H. patagonicus, the snout length is always less than the postorbital length, whereas the snout length of H. erectus is not shorter than the postorbital length in the largest specimens; (2) in both sexes of H. patagonicus, the trunk length:total length (LTr :LT ) is lower than in H. erectus (in female H. patagonicus: 0·27-0·39, H. erectus: 0·36-0·40 and in male H. patagonicus: 0·24-0·34, H. erectus: 0·33-0·43) and (3) in both sexes, tail length:total length (LTa :LT ) in H. patagonicus is larger than in H. erectus (0·61-0·78 v. 0·54-0·64). © 2014 The Fisheries Society of the British Isles.

  7. [Morphometric features of the structure of the central nucleus of the amygdala in men and women].

    Science.gov (United States)

    Antyukhov, A D

    2015-01-01

    To identify the interhemispheric asymmetry in the structure of the central nucleus of the amygdala in men and women. Morphometric features of the structure of neurons of the central nucleus amygdala complex were studied in histological sections of the brain of 6 men and 6 women (24 hemispheres), aged 19 to 55 years, with no lifetime diagnosis of mental or neurological disease. The value of the profile fields of neurons of the central nucleus amygdala complex in the left and right hemispheres of the brain were investigated. In women, the average value of neurons in the left hemisphere was somewhat greater than in the right hemisphere, while in men this value was greater in the right hemisphere. The interhemispheric morphometric differences were not significant regardless of gender. In addition, the quantity of relevant fields of neurons in the central nucleus of the amygdala in women was significantly larger than that of men in both hemispheres. The authors attempted to associate the results obtained in the study with emotional perception in men and women.

  8. Patient dosimetry study of a paediatric CT examination

    International Nuclear Information System (INIS)

    Hranitzky, C.; Stadtmann, H.

    2011-01-01

    Dosimetry studies are of increasing interest in diagnostic high-dose applications such as computed tomography especially for examinations of children. A routine CT scan protocol for paediatric head and neck imaging was investigated at a new multi-detector CT scanner using LiF:Mg,Cu,P thermoluminescence dosemeters (TLDs) and a 0.125 cm 3 thimble ionization chamber. Calibrations of the detectors in terms of absorbed dose to water were carried out at the Dosimetry Laboratory Seibersdorf in standard radiation fields. The dosimetry method was validated in the spiral CT X-ray field by comparing TLD and ionization chamber measurement results in cylindrical PMMA phantoms. Absorbed dose results were within stated uncertainties. An anthropomorphic phantom representing a child of about 5 years was loaded with TLD chips at various organ and tissue positions in the head and neck region as well as at some critical organ locations. Organ dose values were calculated from TLD based average absorbed dose with about 5% total uncertainty, e.g. 22 mGy (eyes), 21 mGy (thyroid), 19 mGy (brain), 3.4 mGy (thymus), and 0.03 mGy (testes). For comparison purposes an effective dose of 1.9 mSv was estimated for the investigated paediatric CT examination based on ICRP-103 age-independent tissue-weighting factors.

  9. Local Application of Growth Hormone to Enhance Osseointegration in Osteoporotic Bones: A Morphometric and Densitometric Study.

    Science.gov (United States)

    Martin-Monge, Elena; Tresguerres, Isabel F; Clemente, Celia; Tresguerres, Jesús Af

    The aim of this study was to assess the effect of local application of growth hormone on osseointegration of dental implants inserted in osteoporotic bones. Twenty female New Zealand rabbits were used in this study. Ten were ovariectomized and fed a low-calcium diet for 6 weeks, and the others remained intact. A titanium implant was inserted into each tibia, in both groups. In half of the rabbits, 2 IU of growth hormone was placed into the ostectomy prior to the implant insertion. Two weeks after implant surgery, all animals were sacrificed. Tibiae were dissected from soft tissues, and included in methacrylate to be studied under light microscopy. Bone-to-implant contact (BIC) and bone mineral density (BMD) were measured by morphometric and densitometric analysis, respectively. Multifactorial analysis of variance (ANOVA) was used for statistical evaluation. P growth hormone was able to increase the BIC in the ovariectomized group, with statistically significant differences with respect to the control group (P growth hormone at the moment of titanium implant insertion in rabbit tibiae significantly enhanced the BIC around titanium implants 15 days after the implantation in this experimental osteoporotic animal model, without affecting the BMD.

  10. Are morphometrics sufficient for estimating age of pre-fledging birds in the field? A test using common terns (Sterna hirundo.

    Directory of Open Access Journals (Sweden)

    Christy N Wails

    Full Text Available Age is a key component of fitness, affecting survival and reproductive capacities. Where it is not possible to study known individuals from birth, morphometrics (predominantly patterns of plumage development for birds are most often used to estimate age. Although criteria for age estimations exist for many species, the degree to which these criteria improve the precision of estimates remains to be tested, restricting their widespread acceptance. We develop a photographic tool for estimating ages of Common Tern (Sterna hirundo chicks and test it using 100 human observers of varying prior experience across four breeding colonies (three North American sites and one European site and under controlled laboratory conditions. We followed the design approach of other morphometric tools, expanding it to create a user-friendly guide (divided into six age groupings. The majority (86% of observers improved in chick-aging accuracy when using the tool by an average of 20.1% (±1.4 SE and correctly estimated 60.3% (±1.4 of chick ages. This was similar to the intrinsic aging ability of our best field observer (63.3%. Observers with limited experience showed the greatest increases in chick-aging accuracy over experienced observers who likely had established a method for estimating chick ages prior to using the tool. Even the best observers only correctly estimated ages of chicks 62.9% (±2.8 of the time in the field and 84.0% (±2.9 of the time in the lab when using the tool and typically underestimated ages. This indicates that developmental variation between individual chicks can prevent completely reliable age estimates and corroborates the few existing data that suggest that morphometric criteria fail to achieve robust levels of accuracy and may introduce error into studies that rely on them. We conclude that novel approaches for estimating age, not only morphometric criteria, must be pursued.

  11. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  12. Seed morphometric characteristics of European species of Elatine (Elatinaceae

    Directory of Open Access Journals (Sweden)

    Agnieszka Popiela

    2017-05-01

    Full Text Available Elatine L. contains ca. 25 small, herbaceous, annual species distributed in ephemeral waters in both hemispheres. All species are amphibious and characterized by a high degree of morphological variability. The importance of seed morphology in Elatine taxonomy has been emphasized by many authors. The degree of seed curvature and seed coat reticulation have been traditionally considered very important in recognizing individual species of this genus. Seed morphometric characteristics of 10 Elatine species, including all European native taxa, are provided on the basis of material from two or three populations of each species. A total of 24–50 seeds were studied from each population, altogether 1,260 images were used for the morphometric study. In total, six parameters were measured from SEM pictures: object surface area, profile specific perimeter (object circuit, rectangle of the object (a length, rectangle of the object (b width, angle of the seed curvature, and number of pits in the seed coat counted in the middle row. Our study shows that the range of morphological variation of seeds in European species of Elatine is great, both between the species and the populations. Discrimination analysis showed that all six traits significantly differentiate the populations studied (λ = 0.001, p < 0.001, and the greatest contributions were “number of pits”, “rectangle_a”, and “the angle curvature”. Multidimensional scaling based on a correlation matrix of Mahalanobis distance of the six features studied revealed the greatest similarity between the three populations of E. alsinastrum, E. macropoda, and E. hexandra. Regarding interspecific differences, a Kruskal–Wallis tests showed that, in many cases, lack of statistically significant differences between species relative to the studied seed traits. If distinction of species is only based on seeds, especially if only a few seeds are evaluated, the following species pairs can be easily

  13. Morphometric Changes in Talus of Club Foot A Gross Observation in Human Foetuses

    OpenAIRE

    Fazal-ur-Rehman,; Faruqi, Nafis A

    2012-01-01

    Both the feet of six human foetuses of different age groups having unilateral club feet, were dissected for morphological study. Six morphometric parameters considered for comparing gross anatomical changes in normal and deformed feet, were 1-Maximum length of the talus, 2-Longitudinal dimension of head of talus, 3-Anterior trochlear breadth, 4-Maximum medial talar height, 5-Talar neck and calcaneal angle, 6-Talocalcaneal angle. All the foetuses with congenital club feet have almost similar d...

  14. Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw [Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Liu, Shu-Hsin [Department of Nuclear Medicine, Buddhist Tzu-Chi General Hospital, 970, Hualien, Taiwan and Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Mok, Greta S. P. [Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, 112, Taipei, Taiwan (China)

    2014-09-15

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

  15. Morphometric analysis of the fiber populations of the rat sciatic nerve, its spinal roots, and its major branches

    NARCIS (Netherlands)

    Prodanov, D.P.; Feierabend, H.K.P.

    2007-01-01

    Correspondence between the nerve composition and the functional characteristics of its fiber populations is not always evident. To investigate such correspondence and to give a systematic picture of the morphology of the rat hind limb nerves, extensive morphometric study was performed on the sciatic

  16. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  17. PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan

    Energy Technology Data Exchange (ETDEWEB)

    Wong, K.; Rahill, J.; Cleary, K. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Petrillo, S.; Earl-Graef, D. [Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Banovac, F.; Levy, E. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Shekhar, R. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    2007-06-15

    Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

  18. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of)

    1994-11-15

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings.

  19. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    International Nuclear Information System (INIS)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung

    1994-01-01

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings

  20. Lung studies with spiral CT. pitch 1 versus pitch 2

    International Nuclear Information System (INIS)

    Sartoni Galloni, S.; Miceli, M.; Lipparino, M.; Burzi, M.; Gigli, F.; Rossi, M.S.; Santoli, G.; Guidarelli, G.

    1999-01-01

    In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality [it

  1. The comparative study of CT and MRI on femoral head necrosis

    International Nuclear Information System (INIS)

    Lin Yunliang; Liu Xianghua; Wu Shiqiang; Zeng Kangnian

    2008-01-01

    Objective: To compare the imaging features of CT and MRI in the femoral head necrosis as well as their pathological basis. Methods: 18 cases (30 hips) with femoral head necrosis proved by follow-up studies or pathology were analyzed, including 3 cases of pathological data. Results: The blurred high-density sclerotic line on CT in 28 hips were corresponded to 'line-like signs' on MRI, whereas, the other two hips without blurred high-density sclerosis line appeared 'line-like signs' on MRI. The normal area surrounded by the high-density line on CT in 26 hips were corresponded to fat-like signal area in 12 hips and mixed signal area in 14 hips on MRI. The other 4 hips with blurred bony trabeculum surrounded by the high-density line on CT showed mixed signal intensity on MRI. Conclusion: The high-density sclerotic line on CT corresponds to 'line-like sign' on MRI, which was considered as reactive interface between necrotic and viable region, was a specific signs to diagnose FHN. Compared with CT, MRI can accurately reflect pathological process during different repaired stages. (authors)

  2. Population structure of the Korean gizzard shad, Konosirus punctatus (Clupeiformes, Clupeidae) using multivariate morphometric analysis

    Science.gov (United States)

    Myoung, Se Hun; Kim, Jin-Koo

    2016-03-01

    The gizzard shad, Konosirus punctatus, is one of the most important fish species in Korea, China, Japan and Taiwan, and therefore the implementation of an appropriate population structure analysis is both necessary and fitting. In order to clarify the current distribution range for the two lineages of the Korean gizzard shad (Myoung and Kim 2014), we conducted a multivariate morphometric analysis by locality and lineage. We analyzed 17 morphometric and 5 meristic characters of 173 individuals, which were sampled from eight localities in the East Sea, the Yellow Sea and the Korean Strait. Unlike population genetics studies, the canonical discriminant analysis (CDA) results showed that the two morphotypes were clearly segregated by the center value "0" of CAN1, of which morphotype A occurred from the Yellow Sea to the western Korean Strait with negative values, and morphotype B occurred from the East Sea to the eastern Korean Strait with positive values even though there exists an admixture zone in the eastern Korean Strait. Further studies using more sensitive markers such as microsatellite DNA are required in order to define the true relationship between the two lineages.

  3. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  4. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  5. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  6. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  7. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  8. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    International Nuclear Information System (INIS)

    Poortman, Pieter; Lohle, Paul N.M.; Schoemaker, Cees M.; Cuesta, Miguel A.; Oostvogel, Henk J.M.; Lange-de Klerk, Elly S.M. de; Hamming, Jaap F.

    2010-01-01

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  9. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  10. Capability of applying morphometric parameters of relief in river basins for geomorphological zoning of a territory

    Science.gov (United States)

    Ivanov, M. A.; Yermolaev, O. P.

    2018-01-01

    Information about morphometric characteristics of relief is necessary for researches devoted to geographic characteristics of territory, its zoning, assessment of erosion processes, geoecological condition and others. For the Volga Federal District for the first time a spatial database of geomorphometric parameters 1: 200 000 scale was created, based on a river basin approach. Watersheds are used as a spatial units created by semi-automated method using the terrain and hydrological modeling techniques implemented in the TAS GIS and WhiteBox GIS. As input data DEMs SRTM and Aster GDEM and hydrographic network vectorized from topographic maps were used. Using DEM highlighted above for each river basin, basic morphometric relief characteristics such as mean height, slope steepness, slope length, height range, river network density and factor LS were calculated. Basins belonging to the geomorphological regions and landscape zones was determined, according to the map of geomorphological zoning and landscape map. Analysis of variance revealed a statistically significant relationship between these characteristics and geomorphological regions and landscape zones. Consequently, spatial trends of changes of analyzed morphometric characteristics were revealed.

  11. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  12. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  13. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  14. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  15. Feasibility of perfusion CT technique integrated into conventional {sup 18}FDG/PET-CT studies in lung cancer patients: clinical staging and functional information in a single study

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide; Capraro, Cristina; Sironi, Sandro [University of Milano-Bicocca, School of Medicine, Milan (Italy); University of Milano-Bicocca, Department of Diagnostic Radiology, H.S. Gerardo Monza, Via Pergolesi 11, Monza, Milan (Italy); Guerra, Luca [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); De Ponti, Elena [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Medical Physics, Monza (Italy); Messa, Cristina [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); Tecnomed Foundation, University of Milano-Bicocca, Institute for Bioimaging and Molecular Physiology, National Research Council, Milan (Italy)

    2013-02-15

    To assess the additional functional vascular information and the relationship between perfusion measurements and glucose metabolism (SUVmax) obtained by including a perfusion CT study in a whole-body contrast-enhanced PET/CT protocol in primary lung cancer lesions. Enrolled in this prospective study were 34 consecutive patients with a biopsy-proven diagnosis of lung cancer who were referred for contrast-enhanced PET/CT staging. This prospective study was approved by our institutional review board, and informed consent was obtained from all patients. Perfusion CT was performed with the following parameters: 80 kV, 200 mAs, 30 scans during intravenous injection of 50 ml contrast agent, flow rate 5 ml/s. Another bolus of contrast medium (3.5 ml/s, 80 ml, 60-s delay) was administered to ensure a full diagnostic contrast-enhanced CT scan for clinical staging. The perfusion CT data were used to calculate a range of tumour vascularity parameters (blood flow, blood volume and mean transit time), and tumour FDG uptake (SUVmax) was used as a metabolic indicator. Quantitative and functional parameters were compared and in relation to location, histology and tumour size. The nonparametric Kruskal-Wallis rank sum test was used for statistical analysis. A cut-off value of 3 cm was used according to the TNM classification to discriminate between T1 and T2 tumours (i.e. T1b vs. T2a). There were significant perfusion differences (lower blood volumes and higher mean transit time) between tumours with diameter >30 mm and tumours with diameter <30 mm (p < 0.05; blood volume 5.6 vs. 7.1 ml/100 g, mean transit time 8.6 vs. 3.9 s, respectively). Also there was a trend for blood flow to be lower in larger lesions (p < 0.053; blood flow 153.1 vs. 98.3 ml/100 g tissue/min). Significant inverse correlations (linear regression) were found between blood volume and SUVmax in tumours with diameter >30 mm in diameter. Perfusion CT combined with PET/CT is feasible technique that may provide

  16. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  17. Quantitative morphologic assessment of thoracolumbar vertebrae in Korean women by morphometric x-ray absorptiometry

    International Nuclear Information System (INIS)

    Cheon, Bong Jin; Huh, Jin Do; Kim, Sung Min; Oh, Kyong Seung; Kim, Jong Min; Jung, Gyoo Sik; Joh, Young Duk

    1999-01-01

    To compare the accuracy of lateral radiography of the spine with that of morphometric X-ray absorptiometry(MXA) in vertebral morphometry, and to evaluate normal vertebral morphometry using MXA in Korean women. A spine phantom was constructed using copper pipe. Its anterior and posterior heights were measured directly, with lateral radiographs and with MXA, and the values thus obtained were compared. Inter- and intra-observer variations were evaluated by three radiologists. The vertebral morphometry of 30 young women volunteers were imaged using thoracic and lumbar lateral radiographs and MXA, and analysis included the measurement of anterior and posterior heights from T4 to L4. We also obtained the vertebral morphometry of 200 normal Korean women who underwent MXA between March 1995 and February 1996, though those with osteoporosis and other spinal lesions were excluded from this study. Thoracolumbar vertebral indexes were statistically correlated with age, height and bone mineral density. There were no statistically significant differences in the heights of spine phantom measured by MXA compared with actual size (mean difference=0.28mm). Simple radiographs were magnified by 23.7% at a phantom-table distance of 15cm, and distortion ranged from 0.5% to 22.5%, depending on phantom level and phantom-table distance. In the study of volunteers, the magnification rate between a simple radiograph and MXA was about 26.6%. Anterior height increased progressively from the thoracic to the lumbar spine, though posterior height peaked at L2, and L4 was less than anterior height. In Korean women, indices of vertebral morphometry decreased significantly with aging, with the most prominent decrease occurring during the seventh decade. The mineral density of spinal bone decreased markedly after the sixth decade. Radiographs showed more magnification and distortion than did MXA, though between morphometric X-ray absorptiometry (MXA) and actual size, there was no significant

  18. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  19. Quantitative morphometric analysis for the tectonic characterisation of northern Tunisia.

    Science.gov (United States)

    Camafort, Miquel; Pérez-Peña, José Vicente; Booth-Rea, Guillermo; Ranero, César R.; Gràcia, Eulàlia; Azañón, José Miguel; Melki, Fetheddine; Ouadday, Mohamed

    2016-04-01

    Northern Tunisia is characterized by low deformation rates and low to moderate seismicity. Although instrumental seismicity reaches maximum magnitudes of Mw 5.5, some historical earthquakes have occurred with catastrophic consequences in this region. Aiming to improve our knowledge of active tectonics in Tunisia, we carried out both a quantitative morphometric analysis and field study in the north-western region. We applied different morphometric tools, like river profiles, knickpoint analysis, hypsometric curves and integrals and drainage pattern anomalies in order to differentiate between zones with high or low recent tectonic activity. This analysis helps identifying uplift and subsidence zones, which we relate to fault activity. Several active faults in a sparse distribution were identified. A selected sector was studied with a field campaign to test the results obtained with the quantitative analysis. During the fieldwork we identified geological evidence of recent activity and a considerable seismogenic potential along El Alia-Teboursouk (ETF) and Dkhila (DF) faults. The ETF fault could be responsible of one of the most devastating historical earthquakes in northern Tunisia that destroyed Utique in 412 A.D. Geological evidence include fluvial terraces folded by faults, striated and cracked pebbles, clastic dikes, sand volcanoes, coseismic cracks, etc. Although not reflected in the instrumental seismicity, our results support an important seismic hazard, evidenced by the several active tectonic structures identified and the two seismogenic faults described. After obtaining the current active tectonic framework of Tunisia we discuss our results within the western Mediterranean trying to contribute to the understanding of the western Mediterranean tectonic context. With our results, we suggest that the main reason explaining the sparse and scarce seismicity of the area in contrast with the adjacent parts of the Nubia-Eurasia boundary is due to its extended

  20. Scaling mimesis: Morphometric and ecomorphological similarities in three sympatric plant-mimetic fish of the family Carangidae (Teleostei).

    Science.gov (United States)

    Queiroz, Alexya Cunha de; Vallinoto, Marcelo; Sakai, Yoichi; Giarrizzo, Tommaso; Barros, Breno

    2018-01-01

    The mimetic juveniles of a number of carangid fish species resemble plant parts floating near the water surface, such as leaves, seeds and other plant debris. The present study is the first to verify the morphological similarities and ecomorphological relationships between three carangids (Oligoplites saurus, Oligoplites palometa and Trachinotus falcatus) and their associated plant models. Behavioral observations were conducted in the estuary of Curuçá River, in northeastern Pará (Brazil) between August 2015 and July 2016. Individual fishes and associated floating objects (models) were sampled for comparative analysis using both geometric and morphometric approaches. While the mimetic fish and their models retain their own distinct, intrinsic morphological features, a high degree of morphological similarity was found between each fish species and its model. The morphometric analyses revealed a general tendency of isometric development in all three fish species, probably related to their pelagic habitats, during all ontogenetic stages.

  1. Association between morphometric variables and nocturnal desaturation in sickle-cell anemia.

    Science.gov (United States)

    Salles, Cristina; Bispo, Marcelo; Trindade-Ramos, Regina Terse

    2014-01-01

    to evaluate associations between morphometric variables, cervical circumference (CC), and abdominal circumference (AC) with the presence of nocturnal desaturation in children and adolescents with sickle-cell anemia. all patients were submitted to baseline polysomnography, oral cavity measurements (maxillary intermolar distance, mandibular intermolar distance, and overjet), and CC and AC measurements. a total of 85 patients were evaluated. A positive correlation was observed between the height/age Z-score and CC measurement (r = 0.233, p = 0.031). The presence of nocturnal desaturation was associated with CC (59.2± 9.3 vs. 67.5 ± 10.7, p = 0.006) and AC measurements (27.0 ± 2.0 vs. 29.0± 2.1, p = 0.028). There was a negative correlation between desaturation and maxillary intermolar distance (r = -0.365, p = 0.001) and mandibular intermolar distance (r = -0.233, p = 0.037). the morphometric variables of CC and AC may contribute to raise suspicion of nocturnal desaturation in children and adolescents with sickle-cell anemia. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. Association between morphometric variables and nocturnal desaturation in sickle-cell anemia

    Directory of Open Access Journals (Sweden)

    Cristina Salles

    2014-07-01

    Full Text Available OBJECTIVE: to evaluate associations between morphometric variables, cervical circumference (CC, and abdominal circumference (AC with the presence of nocturnal desaturation in children and adolescents with sickle-cell anemia. METHODS: all patients were submitted to baseline polysomnography, oral cavity measurements (maxillary intermolar distance, mandibular intermolar distance, and overjet, and CC and AC measurements. RESULTS: a total of 85 patients were evaluated. A positive correlation was observed between the height/age Z-score and CC measurement (r = 0.233, p = 0.031. The presence of nocturnal desaturation was associated with CC (59.2± 9.3 vs. 67.5 ± 10.7, p = 0.006 and AC measurements (27.0 ± 2.0 vs. 29.0± 2.1, p = 0.028. There was a negative correlation between desaturation and maxillary intermolar distance (r = -0.365, p = 0.001 and mandibular intermolar distance (r = -0.233, p = 0.037. CONCLUSIONS: the morphometric variables of CC and AC may contribute to raise suspicion of nocturnal desaturation in children and adolescents with sickle-cell anemia.

  3. CT study in senile dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Yoshida, Ryoichi; Otomo, Eiichi

    1989-01-01

    In order to evaluate the utility of cranial CT in diagnosis of senile dementia of Alzheimer type (SDAT), various CT findings were studied. CT scans of 62 cases of SDAT (83±6 years old) were compared with those of 357 aged cases (means 78±8 years old) without psychiatric and/or neurological illness (normal control NC). The methods of evaluating CT findings were linear measurements of the ventricle, observation of sulci, brain atrophy ranking of microscopic observation, and presence of periventricular lucency. When SDAT were compared with NC, the cases were divided into two groups by the age (the eighth decade, 80 years old or over) to avoid the influence of physiological brain atrophy. In SDAT there was a positive correlation between the volume of the lateral ventricle in autopsy brain and each index which demonstrates the size of the lateral ventricle on CT. In SDAT the incidence of cases with degree III or more was significantly higher than that in NC. It was 82.6% in SDAT, 15.7% in NC in the eighth decade and 92.3% in SDAT, 32.1% in NC in 80 years or over. The mean values of indexes of lateral ventricle enlargement in SDAT increased more than those in NC significantly. In the eighth decade the mean lateral body ratio was 33.8% in SDAT, and 27.0% in NC and in 80 years or over, it was 33.1% in SDAT, 28.1% in NC. The differences between SDAT and NC were statistically significant. In SDAT the incidence of PVL was significantly higher than in NC. The mean maximum width of Sylvian fissure in SDAT was significantly larger than those in NC. However, the width of cingulate sulcus and central sulcus in SDAT were similar to those of NC. Brain atrophy ranking tended to increase with aging in SDAT, but this tendency was less clear than that in NC. In SDAT temporal atrophy was significantly remarkable than the other areas. Overall, CT revealed that brain atrophy in stage III patients was more remarkable than that in stage II patients. (J.P.N.)

  4. CT study in senile dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ryoichi; Otomo, Eiichi [Yokufukai Geriatric Hospital, Tokyo (Japan)

    1989-10-01

    In order to evaluate the utility of cranial CT in diagnosis of senile dementia of Alzheimer type (SDAT), various CT findings were studied. CT scans of 62 cases of SDAT (83{plus minus}6 years old) were compared with those of 357 aged cases (means 78{plus minus}8 years old) without psychiatric and/or neurological illness (NC). To evaluate CT findings linear measurements of the ventricle, observation of sulci, brain atrophy ranking of microscopic observation were compared along with presence of periventricular lucency. When SDAT were compared with NC, the cases were divided into two groups by the age (the eighth decade, 80 years old or over) to avoid the influence of physiological brain atrophy. In SDAT there was a positive correlation between the volume of the lateral ventricle in autopsy brain and each index which demonstrates the size of the lateral ventricle on CT. In SDAT the incidence of cases with degree III or more was significantly higher than that in NC. It was 82.6% in SDAT, 15.7% in NC in the eighth decade and 92.3% in SDAT, 32.1% in NC in 80 years or over. The mean values of indexes of lateral ventricle enlargement in SDAT increased more than those in NC. In the eighth decade the mean lateral body ratio was 33.8% in SDAT, and 27.0% in NC and in 80 years or over, it was 33.1% in SDAT, 28.1% in NC. The differences between SDAT and NC were statistically significant. In SDAT the incidence of PVL was significantly higher than in NC. The mean maximum width of Sylvian fissure in SDAT was significantly larger than those in NC. However, the width of cingulate sulcus and central sulcus in SDAT were similar to those of NC. Brain atrophy ranking tended to increase with aging in SDAT, but this tendency was less clear than that in NC. In SDAT temporal atrophy was more significant than the other areas. Overall, CT revealed that brain atrophy in stage III patients was more remarkable than that in stage II patients.

  5. Life history dependent morphometric variation in stream-dwelling Atlantic salmon

    Science.gov (United States)

    Letcher, B.H.

    2003-01-01

    The time course of morphometric variation among life histories for stream-dwelling Atlantic salmon (Salmo salar L.) parr (age-0+ to age-2+) was analyzed. Possible life histories were combinations of parr maturity status in the autumn (mature or immature) and age at outmigration (smolt at age-2+ or later age). Actual life histories expressed with enough fish for analysis in the 1997 cohort were immature/age-2+ smolt, mature/age-2 +smolt, and mature/age-2+ non-smolt. Tagged fish were assigned to one of the three life histories and digital pictures from the field were analyzed using landmark-based geometric morphometrics. Results indicated that successful grouping of fish according to life history varied with fish age, but that fish could be grouped before the actual expression of the life histories. By March (age-1+), fish were successfully grouped using a descriptive discriminant function and successful assignment ranged from 84 to 97% for the remainder of stream residence. A jackknife of the discriminant function revealed an average life history prediction success of 67% from age-1+ summer to smolting. Low sample numbers for one of the life histories may have limited prediction success. A MANOVA on the shape descriptors (relative warps) also indicated significant differences in shape among life histories from age-1+ summer through to smolting. Across all samples, shape varied significantly with size. Within samples, shape did not vary significantly with size for samples from December (age-0+) to May (age-1+). During the age-1+ summer however, shape varied significantly with size, but the relationship between shape and size was not different among life histories. In the autumn (age-1+) and winter (age-2+), life history differences explained a significant portion of the change in shape with size. Life history dependent morphometric variation may be useful to indicate the timing of early expressions of life history variation and as a tool to explore temporal and

  6. Quantitative diagnosis of bladder cancer by morphometric analysis of HE images

    Science.gov (United States)

    Wu, Binlin; Nebylitsa, Samantha V.; Mukherjee, Sushmita; Jain, Manu

    2015-02-01

    In clinical practice, histopathological analysis of biopsied tissue is the main method for bladder cancer diagnosis and prognosis. The diagnosis is performed by a pathologist based on the morphological features in the image of a hematoxylin and eosin (HE) stained tissue sample. This manuscript proposes algorithms to perform morphometric analysis on the HE images, quantify the features in the images, and discriminate bladder cancers with different grades, i.e. high grade and low grade. The nuclei are separated from the background and other types of cells such as red blood cells (RBCs) and immune cells using manual outlining, color deconvolution and image segmentation. A mask of nuclei is generated for each image for quantitative morphometric analysis. The features of the nuclei in the mask image including size, shape, orientation, and their spatial distributions are measured. To quantify local clustering and alignment of nuclei, we propose a 1-nearest-neighbor (1-NN) algorithm which measures nearest neighbor distance and nearest neighbor parallelism. The global distributions of the features are measured using statistics of the proposed parameters. A linear support vector machine (SVM) algorithm is used to classify the high grade and low grade bladder cancers. The results show using a particular group of nuclei such as large ones, and combining multiple parameters can achieve better discrimination. This study shows the proposed approach can potentially help expedite pathological diagnosis by triaging potentially suspicious biopsies.

  7. Multi-level tree analysis of pulmonary artery/vein trees in non-contrast CT images

    Science.gov (United States)

    Gao, Zhiyun; Grout, Randall W.; Hoffman, Eric A.; Saha, Punam K.

    2012-02-01

    Diseases like pulmonary embolism and pulmonary hypertension are associated with vascular dystrophy. Identifying such pulmonary artery/vein (A/V) tree dystrophy in terms of quantitative measures via CT imaging significantly facilitates early detection of disease or a treatment monitoring process. A tree structure, consisting of nodes and connected arcs, linked to the volumetric representation allows multi-level geometric and volumetric analysis of A/V trees. Here, a new theory and method is presented to generate multi-level A/V tree representation of volumetric data and to compute quantitative measures of A/V tree geometry and topology at various tree hierarchies. The new method is primarily designed on arc skeleton computation followed by a tree construction based topologic and geometric analysis of the skeleton. The method starts with a volumetric A/V representation as input and generates its topologic and multi-level volumetric tree representations long with different multi-level morphometric measures. A new recursive merging and pruning algorithms are introduced to detect bad junctions and noisy branches often associated with digital geometric and topologic analysis. Also, a new notion of shortest axial path is introduced to improve the skeletal arc joining two junctions. The accuracy of the multi-level tree analysis algorithm has been evaluated using computer generated phantoms and pulmonary CT images of a pig vessel cast phantom while the reproducibility of method is evaluated using multi-user A/V separation of in vivo contrast-enhanced CT images of a pig lung at different respiratory volumes.

  8. Morphometric study on age-dependent pulmonary lesions in rats exposed to nitrogen dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Kyono, H.; Kawai, K.

    1982-01-01

    Electronmicroscopic morphometry was performed on lung of 1, 3, 12 and 21 months-old rats exposed to 0.1, 0.5, 3 and 10 ppm nitrogen dioxide (NO/sub 2/) continuously for one month. The rats used in this experiment were all supplied at one time from one colony and kept under a barrier system until exposure. Effects of aging on the responses of lungs to NO/sub 2/ were studied by comparing the dose-effect reaction patterns among the age groups. A trend of dose-dependent increase of arithmetic mean thickness of air-blood barrier was found in all age groups examined. The response of lung to NO/sub 2/ exposure showed age-related differences. Based on the morphometric index, the response declines from 1 to 12 months, but increases again in 21-months-old rats. The compartmental components of alveolar wall tissue such as type I epithelial cells, type II epithelial cells, interstitial cells, interstitial matrix and capillary endothelium appeared to have various degrees of response due to both age at onset of exposure and NO/sub 2/ concentration, resulting in the appearance of varying stages in impairment or repair. Accordingly, the response of each compartmental component of lung to the concentrations of NO/sub 2/ did not always exhibit a simple dose-dependent increase or decrease but sometimes indicated a multiphasic reaction pattern.

  9. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  10. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  11. Comparação morfométrica da orelha interna entre ovinos e humanos através da tomografia computadorizada CT-Scan sheep and human inner ear morphometric comparison

    Directory of Open Access Journals (Sweden)

    Valter Ayres Seibel

    2006-06-01

    Full Text Available INTRODUÇÃO: trabalhos sobre o uso de ovelhas em cirurgias experimentais e treinamento em cirurgia otológica são raros. Este estudo pretende contribuir para ampliar o conhecimento nessa área. OBJETIVO: Estudar a orelha interna da ovelha por meio de tomografia computadorizada e cortes sucessivos com o intuito de apresentar dados morfométricos mais precisos relacionados à comparação entre a orelha de ovelhas e a de humanos. MATERIAL E MÉTODO: Foi realizado um estudo descritivo sem seguimento no qual foram comparadas as estruturas da orelha interna da ovelha com as dos humanos. As medidas foram obtidas através de tomografias computadorizadas e avaliadas por meio de um programa de análise de imagens médicas (Osíris 4.16. RESULTADOS: O estudo morfológico da orelha da ovelha, em média, e da orelha humana, em média, revelaram grande similaridade de anatomia. A maior parte das estruturas (10 de 15 preservou a relação proposta de 2/3 da dimensão humana em relação à dimensão ovina. CONCLUSÃO: Os achados contribuem para uso da orelha da ovelha como modelo em cirurgia experimental e treinamento em cirurgia otológica.INTRODUCTION: Studies about the use of sheep in surgical training and experimental otologic surgery are rare. This study intends to contribute to the knowledge on this field. AIM: To study sheep inner ear structures using computerized tomography and serial cross-sections to collect more accurate morphometric data to compare sheep and human ears. MATERIAL AND METHODS: This descriptive study compared the inner structures of sheep and human ears. Measurements were made using computerized tomography, and they were stored in a DICOM compact disc for later analysis and manipulation, with a program used for medical image analysis (Osíris 4.16. RESULTS: Mean measures for sheep and human ears were found to be similar in this morphological study. Most structures (10 out of 15 maintained the 2/3 ratio of sheep to human ear

  12. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    International Nuclear Information System (INIS)

    Kamijo, Keiichi

    1994-01-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122±18 H.U.(±SD) and did not change significatly with advancing age. The mean thyroid CT number (±SD) of 85±22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116±22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T 3 were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65±11 H.U. and increased significantly to 76±14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102±11 H.U. and fell significantly to 84±16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57±7 H.U. in 6 patients with silent thyroiditis and of 61±5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author)

  13. A combined morphometric analysis of foot form and its association with sex, stature, and body mass.

    Science.gov (United States)

    Domjanic, Jacqueline; Seidler, Horst; Mitteroecker, Philipp

    2015-08-01

    Morphometric analysis of footprints is a classic means for orthopedic diagnosis. In forensics and physical anthropology, it is commonly used for the estimation of stature and body mass. We studied individual variation and sexual dimorphism of foot dimensions and footprint shape by a combination of classic foot measurements and geometric morphometric methods. Left and right feet of 134 healthy adult males and females were scanned twice with a 3D optical laser scanner, and stature as well as body mass were recorded. Foot length and width were measured on the 3D scans. The 2D footprints were extracted as the plantar-most 2 mm of the 3D scans and measured with 85 landmarks and semilandmarks. Both foot size and footprint shape are sexually dimorphic and relate to stature and body mass. While dimorphism in foot length largely results from dimorphism in stature, dimorphism in footprint shape partly owes to the dimorphism in BMI. Stature could be estimated well based on foot length (R(2)  = 0.76), whereas body mass was more closely related to foot width (R(2)  = 0.62). Sex could be estimated correctly for 95% of the individuals based on a combination of foot width and length. Geometric morphometrics proved to be an effective tool for the detailed analysis of footprint shape. However, for the estimation of stature, body mass, and sex, shape variables did not considerably improve estimates based on foot length and width. © 2015 Wiley Periodicals, Inc.

  14. Morphometric characteristics of sweet chestnut (Castanea sativa Mill. fruits

    Directory of Open Access Journals (Sweden)

    Oľga Grygorieva

    2017-01-01

    Full Text Available Aim of this study was to determine morphometric differences of fruits between selected sweet chestnuts (Castanea sativa Mill.. The 28 genotypes (referred as CS-01 to CS-28 were introduced by seeds from Czech Republic, Carpathians, Kyrgyzstan. Genotypes of sweet chestnut are grow more than 30 years in Forest-Steppe of Ukraine in the M.M. Gryshko National Botanical Garden of NAS of Ukraine. They are well adapted to the climatic and soil conditions. The fruits were collected at the period of their full maturity (September. The population differs in weight, shape, size and color of fruits. Their morphometric parameters were following: weight from 1.70 g (CS-26 to 18.60 g (CS-20, length from 8.07 mm (CS-28 to 33.39 mm (CS-11, width from 16.34 mm (CS-28 to 40.95 mm (CS-11, thickness from 9.02 mm (CS-26 to 28.70 mm (CS-11 and hilum length from 6.62 mm (CS-26 to 31.30 mm (CS-07, hilum width from 6.50 mm (CS-23 to 19.99 mm (CS-07. The shape index of the fruits was found in the range of 0.81 (CS-20 to 0.98 (CS-12. The shape index of the hilum was found in the range of 1.48 (CS-04 to 2.03 (CS-23. The outcome of the research point to the fact that the genepool Ukrainian sweet chestnut is a rich source of genetic diversity and might be used in selection for creation a new genotypes and cultivars. Normal 0 21 false false false EN-GB X-NONE X-NONE Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  15. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  16. Applications of wavelets in morphometric analysis of medical images

    Science.gov (United States)

    Davatzikos, Christos; Tao, Xiaodong; Shen, Dinggang

    2003-11-01

    Morphometric analysis of medical images is playing an increasingly important role in understanding brain structure and function, as well as in understanding the way in which these change during development, aging and pathology. This paper presents three wavelet-based methods with related applications in morphometric analysis of magnetic resonance (MR) brain images. The first method handles cases where very limited datasets are available for the training of statistical shape models in the deformable segmentation. The method is capable of capturing a larger range of shape variability than the standard active shape models (ASMs) can, by using the elegant spatial-frequency decomposition of the shape contours provided by wavelet transforms. The second method addresses the difficulty of finding correspondences in anatomical images, which is a key step in shape analysis and deformable registration. The detection of anatomical correspondences is completed by using wavelet-based attribute vectors as morphological signatures of voxels. The third method uses wavelets to characterize the morphological measurements obtained from all voxels in a brain image, and the entire set of wavelet coefficients is further used to build a brain classifier. Since the classification scheme operates in a very-high-dimensional space, it can determine subtle population differences with complex spatial patterns. Experimental results are provided to demonstrate the performance of the proposed methods.

  17. Morphologic and morphometric evaluation of pancreatic islets in chronic Chagas' disease

    Directory of Open Access Journals (Sweden)

    Saldanha João Carlos

    2001-01-01

    Full Text Available PURPOSE: Hyperglycemia and abnormal glucose tolerance tests observed in some patients with chronic Chagas' disease suggest the possibility of morphological changes in pancreatic islets and/or denervation. The purpose of this study was to describe the morphology and morphometry of pancreatic islets in chronic Chagas' disease. METHODS: Morphologic and computerized morphometric studies were performed in fragments of the head, body, and tail regions of the pancreas obtained at necropsies of 8 normal controls and 17 patients with chronic Chagas' disease: 8 with the digestive form (Megas and 9 with the congestive heart failure form. RESULTS: The Megas group had a larger (p < 0.05 pancreatic islet area in the tail of the pancreas (10649.3 ± 4408.8 µm² than the normal control (9481.8 ± 3242.4 µm² and congestive heart failure (9475.1 ± 2104.9 µm² groups; likewise, the density of the pancreatic islets (PI was greater (1.2 ± 0.7 vs. 0.9 ± 0.6 vs. 1.9 ± 1.0 PI/mm², respectively. In the tail region of the pancreas of patients with the Megas form, there was a significant and positive correlation (r = +0.73 between the area and density of pancreatic islets. Discrete fibrosis and leukocytic infiltrates were found in pancreatic ganglia and pancreatic islets of the patients with Chagas' disease. Trypanosoma cruzi nests were not observed in the examined sections. Individuals with the Megas form of Chagas' disease showed increased area and density of pancreatic islets in the tail of the pancreas. CONCLUSION: The observed morphometric and morphologic alterations are consistent with functional changes in the pancreas, including glycemia and insulin disturbances.

  18. Effects of peroral supplementation of different forms of zinc on the ruminal mucosa of goat kids – a morphometric study

    Directory of Open Access Journals (Sweden)

    Julius Černík

    2013-01-01

    Full Text Available The aim of the study was to identify the effect of supplementation of various forms of zinc on the ruminal mucosa and dimensions of ruminal papillae in 6-month-old goat kids. The experimental period lasted from weaning to slaughter (4 months. All 20 kids divided into four groups of five animals, were fed with the same feeding dose, which was different only in the quantity and form of zinc. Control group was without additional zinc supplementation (group A, the other groups were supplemented with zinc in the form of ZnO (group B, zinc in the form of chelate (group C and zinc in the form of lactate (group D. Samples for histopathological and morphometric examination were collected after the slaughter of all animals from the bottom of saccus ruminis ventralis everytime from the same place. Significant differences were reported within the comparison of the length of ruminal papillae between groups B and C (P = 0.026 and B and D (P = 0.040, within the comparison of the width of ruminal papillae between groups A and D (P = 0.020 and within the comparison of the intensity of keratinisation of the mucosa of ruminal papillae between groups A and B (P = 0.034, A and C (P = 0.038 and A and D (P = 0.001. Histopathological and morphometric examination of ruminal mucosa indicated that the ruminal papillae of kids supplemented with zinc in the form of ZnO (group B were better developed compared to the other groups. This result indicates better utilisation of the supplemented zinc in the form of ZnO.

  19. Possibility of Morphometrical Determining of Sex of Steppe Eagle Nestlings from Western and Eastern Populations?

    Directory of Open Access Journals (Sweden)

    Igor V. Karyakin

    2018-03-01

    Full Text Available Sexual dimorphism among nestlings of the Steppe Eagle (Aquila nipalensis is poorly manifested. Thus, determining of sex by morphometric methods encountered many difficulties and could be completed only by the most experienced ornithologists who knows the species very well. This article presents a morphometric method for determining sex of nestlings of the Steppe Eagles from different breeding populations that belongs to different size classes. The method is based on classification formula obtained via linear discriminant analysis conducted for the data set of measurements of Steppe Eagle’s nestlings from Central Kazakhstan and Altai Republic in 2017. To control the sex determination of nestlings a molecular-genetics method was used.

  1. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  2. The morphological and morphometric study of tissues of dentoalveolar system in children with impaired course of the antenatal period

    Directory of Open Access Journals (Sweden)

    Drogomiretskaya M.S.

    2016-03-01

    Full Text Available Anomalies and deformation of dental system in children and adolescents contribute not only to the deterioration of dental health, bat quite often this is the cause of a wide range of somatic pathology. The aim of our study was to determine risk factors of dental system myofunctional disorders in children with impaired course of the antenatal period using morphological and morphometric studies. The changes that have been defined in the organs examined were dystrophic and dyscirculatory and differed in degrees of severity in all parts of the oral cavity. Dystrophic changes were detected in the gums and tongue epithelium. Dyscirculatory disorders were characterized by formation of submucosal edema, development of the vascular bed hyperemia and presence of hemorrhage under the basement membrane of the epithelium and salivary gland stroma. Pronounced changes were recorded in the nerve cells of the oral cavity.

  3. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  4. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  5. Distribution of Vascular Patterns in Different Subtypes of Renal Cell Carcinoma. A Morphometric Study in Two Distinct Types of Blood Vessels.

    Science.gov (United States)

    Ruiz-Saurí, Amparo; García-Bustos, V; Granero, E; Cuesta, S; Sales, M A; Marcos, V; Llombart-Bosch, A

    2017-07-01

    To analyze the presence of mature and immature vessels as a prognostic factor in patients with renal cell carcinoma and propose a classification of renal cancer tumor blood vessels according to morphometric parameters. Tissue samples were obtained from 121 renal cell carcinoma patients who underwent radical nephrectomy. Staining with CD31 and CD34 was used to differentiate between immature (CD31+) and mature (CD34+) blood vessels. We quantified the microvascular density, microvascular area and different morphometric parameters: maximum diameter, minimum diameter, major axis, minor axis, perimeter, radius ratio and roundness. We found that the microvascular density was higher in CD31+ than CD34+ vessels, but CD34+ vessels were larger than CD31+ vessels, as well as being strongly correlated with the ISUP tumor grade. We also identified four vascular patterns: pseudoacinar, fascicular, reticular and diffuse. Pseudoacinar and fascicular patterns were more frequent in clear cell renal cell carcinoma (37.62 and 35.64% respectively), followed by reticular pattern (21.78%), while in chromophobe tumors the reticular pattern predominated (90%). The isolated pattern was present in all papillary tumors (100%). In healthy renal tissue, the pseudoacinar and isolated patterns were differentially found in the renal cortex and medulla respectively. We defined four distinct vascular patterns significantly related with the ISUP tumor grade in renal cell carcinomas. Further studies in larger series are needed in order to validate these results. Analysis of both mature and immature vessels (CD34+ and CD31+) provides additional information when evaluating microvascular density.

  6. Evaluation of radiation dose in pediatric head CT examination: a phantom study

    Science.gov (United States)

    Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, Ahmad Taufek Abdul

    2018-01-01

    The aim of this study was to evaluate the radiation dose in pediatric head Computed Tomography examination. It was reported that decreasing tube voltage in CT examination can reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The average dose was 2.60 mGy at CT imaging parameters of 80 kV and 10 - 30 mAs. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

  7. A study of long boone measurement by CT scanogram - Comparison with spot scanogram -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Kang, Heung Sik; Jung, Jin Wook; Yeon, Kyung Mo

    1987-01-01

    CT scanogram is a new technique for measuring leg length discrepancy and has many advantage as compared with conventional spot scanogram. 30 dried bones were measured by direct measurement, spot scanogram and CT scanogram. Accuracy of CT scanogram was compared with spot scanogram. For evaluation of systemic error of CT, steel rulers and dried bones were measured at two different window settings. Decentering error in spot scanogram was measured by using dried bones, and 180 spots of 30 clinical cases of Beli-thompson studies were reviewed for evaluation of incidence and degree of decentering. The results of measurements of CT and spot scanogram in ideal position and technique were equivalent to those of direct measurements. But in spot scanogram, significant errors were noted in flexion status and decentered film. 54 spot (42.9%) of 30 clinical cases were decentered more than 1 cm. In CT scanogram, decentering error was completely excluded and shortening due to flexion deformity was overcomed by lateral scanogram. CT scanogram is a simple and accurate method for leg length measurement. Thus we recommend CT scanogram as a routine use for evaluation of leg length discrepancy.

  8. Assessing population-level morphometric variation of the Mountain Mullet Agonostomus monticola (Teleostei: Mugilidae across its Middle American distribution

    Directory of Open Access Journals (Sweden)

    Bertha P. Díaz-Murillo

    2017-12-01

    Full Text Available ABSTRACT Population-level morphometric variation of the Mountain Mullet (Agonostomus monticola was assessed in 419 adult specimens from 25 sample sites (river basins across its Middle American distribution (Pacific and Atlantic-Caribbean drainages. This analysis was based on 36 standardized linear measurements and 19 landmarks on geometric morphometrics approach. Discriminant function analysis (DFA revealed 19 linear morphological characters with significant variation among groups. Geometrically, the most notable changes were associated to the curvature of the frontal region of the head, the anterior and posterior insertion of the first dorsal and anal fins. The resulting grouping based on the DFA and geometric morphometrics techniques (Pacific-A, Pacific-B and NE México-Caribbean were similar to those previously recovered by genetic techniques, where the Pacific-B (Ayuquila river basin was the most different group. Our results provide morphological evidence for considering Agonostomus monticola as a complex of evolutionary entities, represented by two forms in the Pacific Ocean and another in the Atlantic Ocean.

  9. CT study in primary low spinal fluid pressure syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Moritoshi; Okayama, Kenji; Kubo, Hiromasa; Watanabe, Hiromi; Endou, Riuko (Ohmiya Red Cross Hospital, Yono, Saitama (Japan))

    1991-02-01

    CT findings in primary low spinal fluid pressure syndrome were studied on the basis of 3 cases. Case 1 was a 43-year-old male with a complicated bilateral isodense subdural hematoma (SDH). Case 2 was a 45-year-old female with a complicated bilateral high dense SDH. Case 3 was a 36-year-old female discharged without any complications after spinal fluid pressure normalized. Slight downward displacement of the brain under low spinal fluid pressure was shown as the narrowing of a Sylvian fissures and infratentorial cisterns on CT. On the other hand, in this syndrome with a complicated bilateral isodense SDH, in addition to this finding, CT revealed distortion and narrowing of body lateral ventricles, which might be differential findings from this syndrome without complicated SDH. Under low spinal fluid pressure, bridging veins are more stretched by a downward displacement of the brain. And consequently they were easily injured and SDH was developed. (author).

  10. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  11. Intracranial ring enhancing lesions in dogs: a correlative CT scanning and neuropathologic study

    International Nuclear Information System (INIS)

    Wolf, Michael; Pedroia, Vince; Higgins, Robert J.; Koblik, Philip D.; Turrel, Jane M.; Owens, Jerry M.

    1995-01-01

    This retrospective analysis of 15 dogs with postcontrast ring enhancing brain lesions, each detected by a single Computed Tomography (CT) examination, searched for any association between their CT appearance and the pathologic diagnosis. In a subgroup of these dogs (n = 71) necropsied within 2 days of the last CT scan, we evaluated whether there was any anatomic correlation between the ring zone and the histopathologic features of the lesions. Our study consisted of eight dogs with primary brain tumors (3 meningiomas, 3 astrocytomas, 1 mixed glioma, 1 oligodendroglioma), 4 with metastatic brain tumors (2 fibrosarcomas, 1 mammary carcinoma, 1 melanoma) and 3 with non-neoplastic brain lesions (2 intraparenchymal hemorrhages, 1 pyogranulomatous meningoencephalitis). The overall size and shape of the contrast enhancing CT lesions, as well as the thickness, surface texture and degree of enhancement of the ring were subjectively evaluated. No association was found between the CT lesion characteristics and the pathologic diagnosis. In the sub-group of dogs euthanatized within 2 days of the CT examination, distinct histologic features which anatomically correlated with the zone of ring enhancement were found in 3 of 7 lesions. The findings of this study are consistent with those of ring-enhancing lesions in people, and indicates that CT ring enhancement is a nonspecific phenomenon which can occur in a variety of neoplastic and non-neoplastic lesions in the dog

  12. Dosimetry of inhaled plutonium-239 dioxide in rodent lung: a morphometric study

    International Nuclear Information System (INIS)

    Rhoads, K.

    1979-06-01

    Morphometric analysis of rat and hamster lung did not demonstrate any extensive changes in lung composition or structure following inhalation exposure to 239 Pu0 2 at levels near that for maximum tumor yield in rats. The problem of dosimetry for this compound thus appears to be relatively uncomplicated by any major radiation-induced pathological alterations in the lung. Rat and hamster lung were found to be similar in structure and composition, with few significant differences which could be directly related to the different tumor responses. The distribution of 239 Pu0 2 particles was not uniform in all regions of the lung; thus estimation of the dose to specific tissues or regions within the lung requires a correction for this effect. Species differences were found for particle distribution in the subpleural region and major airways, and in the spatial association of particles, both of which may affect the tumor development process. These regions contain the principal target cells for tumor production and serve as foci for the origin of tumors. Different dose distributions within these regions may therefore explain, at least in part, the difference in tumor response to inhaled 239 Pu0 2 for rats and hamsters

  13. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  14. Morphological and Morphometrical Description of Trichostrongylus Species Isolated from Domestic Ruminants in Khuzestan Province, Southwest Iran

    Directory of Open Access Journals (Sweden)

    B Golestan

    2011-09-01

    Full Text Available Backgrounds: Genus Trichostrongylus (Nematoda: Trichostrongylidae is one of the most impor­tant zoonotic nematodes with wide geographic distribution in the world. The purpose of the present study was to describe morphological and morphometrical characteristics of male Trichostrongylus species, currently prevalent in domestic ruminants of Khuzestan Province, south­west Iran.Methods: Gastro-intestinal organs of 1600 sheep, goats, cattle, and buffalos, slaughtered in Khuzestan Province, southwest Iran, were examined for infectivity with Trichostrongylus spe­cies. For examination and measurements of helminthes, Azo-carmine staining was per­formed, followed by camera lucida drawings of morphological characters and measurements of morphometrical criteria with a calibrated microscope. Using valid nematodes systematic keys, almost all the parasites were identified at the level of species.Results: Overall, 114 animals were found infected with at least one species of Trichostrongy­lus. Considering morphological characteristics of male Trichostrongylus, six species were identi­fied including T. colubriformis, T. vitrinus, T. probolorus, T. capricola, T. longispicu­laris and Trichostrongylus sp. Conclusion: Although, compared to the previous decades, currently Trichostrongylus is much less prevalent in the domestic ruminants of the study area, but still different species occur in these animals.

  15. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  16. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  17. Diagnostic accuracy of FDG PET/CT in mediastinal lymph nodal staging of the non-small cell lung cancer: prospective study with PET/CT of 182 cases

    International Nuclear Information System (INIS)

    Lee, J. W.; Kang, W. J.; Kim, B. S.; Lee, D. S.; Jeong, J. K.; Lee, M. C.

    2007-01-01

    This study was performed to assess the accuracy of fluorodeoxyglucose - positron emission tomography/computed tomography (FDG-PET/CT) in the mediastinal lymph nodal staging of non-small cell lung cancer as compared with CT. Between March 2004 and February 2006, 182 patients (126 men and 56 women; mean age, 60.7 y) with non-small cell lung cancer underwent FDG PET/CT and enhanced chest CT. PET/CT and CT images were acquired in a prospective manner. These images were evaluated separately by 2 different physicians and nodal stages were determined by using American Joint Committee on Cancer staging systems. The maxSUV, location, size, calcification and pattern of FDG uptake of lymph nodes were considered. Surgical and histological findings served as the reference standard. A total of 182 patients with 778 mediastinal nodal stations were evaluated. Among them, metastases were found in 36 patients with 53 nodal stations. The respective values for sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mediastinal lymph node staging were 36%, 80%, 30%, 84% and 71% with CT and 75%, 89%, 63%, 94% and 86% with PET/CT on per-patient basis, and 23%, 92%, 18%, 94% and 88% with CT and 66%, 96%, 54%, 98% and 94% with PET/CT on per-nodal-station basis. The maxSUVs of metastatic lymph nodes were significantly higher than those of benign nodes (p = 0.0008). Seventy seven percent (27/35) of the metastatic lymph nodes on FDG-PET/CT images were less than a 1cm in the short axis. Moreover, some benign lymph node patterns, such as bilateral symmetric nodes with similar FDG uptake, benign pattern of nodal calcification and small-sized lymph node with much higher maxSUV than primary tumor, were noted during the evaluation of FDG-PET/CT images. This prospective study suggests that FDG-PET/CT is more accurately stage the mediastinal lymph node staging than CT, and that it provides high specificity and a negative predictive value

  18. CT in the study of thoracic-pulmonary complications after liver transplantation

    International Nuclear Information System (INIS)

    Robiati, S.; Veltri, A.; Martina, M. C.; Gariazzo, G.; Gandini, G.; Cerutti, E.; Ottobrelli, A.

    2000-01-01

    In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) examinations had been performed with conventional CT scanning (100 with i.v. contrast agent and 33 without) and 19/152 (12.5%) with HRCT. Twenty of 152 (13.2%) examinations, in 16 patients were normal; in the other 84 patients, 132/152 (86.8%) CT/HRCT studies showed 247 pathological findings (99 pleural effusions, 3 pericardial effusions, 62 cases of atelectasis, 1 pulmonary calcification, 70 suspected inflammatory parenchymal consolidations, 64 of them alveolar and 6 interstitial, 4 cases of interstitial edema and finally 8 neoplastic infiltrates). Correlated with clinical data, CT findings are very useful in detailing clinical-radiographic screening findings, despite the limitations in typifying pleural effusions, in differentiating atelectasis from inflammatory parenchymal consolidations and in assessing pneumonia etiology. Also, despite its high sensitivity (94.1%) and specificity (92.8%), CT was not accurate enough in the differential diagnosis of pneumonia. History data were necessary to characterize the histology of

  19. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  20. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    Energy Technology Data Exchange (ETDEWEB)

    Kamijo, Keiichi (Kamijo Thyroid and Pituitary Clinic, Sapporo (Japan))

    1994-02-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122[+-]18 H.U.([+-]SD) and did not change significatly with advancing age. The mean thyroid CT number ([+-]SD) of 85[+-]22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116[+-]22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T[sub 3] were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65[+-]11 H.U. and increased significantly to 76[+-]14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102[+-]11 H.U. and fell significantly to 84[+-]16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57[+-]7 H.U. in 6 patients with silent thyroiditis and of 61[+-]5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author).

  1. A CT study of the prevalence of carotid artery calcification in dental patients

    International Nuclear Information System (INIS)

    Yoon, Suk Ja; Lee, Jae Seo; Yoon, Woong

    2006-01-01

    Stroke is one of the leading causes of death in Korea. Atherosclerotic disease in the carotid artery bifurcation is the most common cause of stroke. The carotid artery calcification is easily appreciated by CT(Computed tomography). CT is often taken in a dental hospital for the diagnosis of inflammation. injury, cyst or tumor on maxillofacial region. However, there was no report of carotid artery calcification on CT in dental patients. The presence of carotid artery calcification was evaluated by an experienced radiologist on CT scans of 287 patients (166 males, 121 females, average age 42, range 6 to 86 years) and the medical history of the patient and the interpretation of CT were reviewed. Carotid artery calcification was detected on CT scans of 57 patients (19.8%; 35 males, 22 females). All the male patients with carotid artery calcification were older than 50, and all the female patients with carotid artery calcification were older than 60. Among the 57 patients, 10 had Diabetes mellitus, 20 had cardiovascular disease, 3 had history of stroke and 3 underwent radiation therapy for head and neck cancer. Carotid artery calcification was not included in the interpretation of CT of dental patients except one patient. The prevalence of carotid artery calcification on CT of dental patients was about 20% in this study. Carotid artery calcification should be included in the interpretation of CT of dental patients

  2. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  3. Morphometric Measurements of Bony Nasolacrimal Canal in Children.

    Science.gov (United States)

    Ela, Araz Server; Cigdem, Kalaycik Ertugay; Karagoz, Yesim; Yigit, Ozgur; Longur, Ecem Sevim

    2018-05-01

    Morphology and dimensions of the bony nasolacrimal canal duct (BNLD) as a key factor in the development of primary acquired nasolacrimal duct obstruction. We aimed to obtain detailed morphometric analysis of BNLD in children without nasolacrimal duct pathology by using computed tomography and provide standard measurements by means of age which could be utilized in planning management or in invasive interventions. Picture Archiving Communication Systems database of our hospital's radiology department was searched for this retrospective study. Subjects were under 18 years of age who had undergone a paranasal, maxillofacial, or temporal bone high-resolution computed tomography scan in last 2 years with various indications. Those with fractures including facial bones and/or nasolacrimal canal or history of nasolacrimal duct pathology were excluded from the study. We measured the diameter, angle, and surface area of BNLD. A total number of 136 subjects (86 boys, 50 girls) were included in the study. The average age was 7.3 ± 5.1 years. We documented statistically significantly positive correlation between all measured diameters and ages (P  0.050). Our study demonstrated that development of BNLD continues during childhood, regardless of gender.

  4. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  5. The effect of morphometric scaling on deposition and clearance of inhaled radionuclides

    International Nuclear Information System (INIS)

    Bergmann, R.; Hofmann, W.; Koblinger, L.

    1996-01-01

    The linear dimensions of present lung models are based on morphometric measurements on fully inflated lungs. To simulate deposition and clearance of inhaled radionuclides in human lungs under normal breathing conditions, airway diameters and lengths have to be scaled down to the smaller dimensions at functional residual capacity of about 3000 ml

  6. PATHOMORPHOLOGICAL FEATURES OF BONE LESIONS AND CORRELATION OF CLINICAL, LABORATORY AND MORPHOMETRIC CRITERIA IN PATIENTS WITH LATENT SCLEROSING HEMATOGENOUS OSTEOMYELITIS (GARRÉ

    Directory of Open Access Journals (Sweden)

    V. V. Grigorovsky

    2018-01-01

    Full Text Available Introduction. Sclerosing hematogenous osteomyelitis of Garré (SHO holds a significant place among cases of latent hematogenous osteomyelitis. Pathomorphological studies of sclerosing hematogenous osteomyelitis are needed to improve differentiated diagnostics, to prognosticate morphology specifics of nidus and to choose the optimal treatment tactics.Purpose of the study — to identify statistical differences between manifestation patterns of various disease types and correlation between clinical, laboratorial and morphometric criteria of bone lesions in patients with sclerosing hematogenous osteomyelitis.Material and methods. The authors studied tissue fragments of affected bones of 25 patients with SHO which was diagnosed by clinical, laboratorial, visualizing and morphological methods. Gradation morphometric criteria were used to reflect condition of nidus tissues. The authors made the analysis of qualitative characters and correlation analysis of dependencies between clinical and laboratorial criteria on the one hand, and with morphometric criteria — on the other, and identified association factor. Results. Pathomorphological study of SHO nidus demonstrated variances of bone lesions in separate disease cases despite the overall similarity of morphological manifestation. About 2/3 of all cases correspond to fibrosing type whereby even small exudative inflammation sites are absent. In about 1/3 of all cases apart from fibrosis, osteosclerosis and remodeling, the osteomyelitis niduses contain microabscesses indicative of suppurative inflammation as well as the authors observed small sequestration. The maximum differences in patients with various types of SHO were identified in such parameters as share of stab microphages and erythrocyte sedimentation rate (ESR. In cases of long term morbidity the fibrosing disease type is prevailing, in cases of short term lesion (1–2 years — a fibrosing type with microabscesses formation.A series of

  7. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  8. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  9. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  10. Studies on diagnosis of lung emphysema by CT image using experimental models and clinical cases

    International Nuclear Information System (INIS)

    Nakatani, Seiki

    1998-01-01

    Since the detailed report between the degree of functional disorder in lung emphysema and the analysis of CT image is quite unknown, the present study was attempted to produce the experimental model of lung emphysema with various stages by the administration of papain to the focal lobe in canine lung. Using this model or clinical lung emphysema, the relationship between the degree of destruction of alveolar walls, clinical pulmonary functions and CT images was investigated. CT scan was performed at the level of 50% vital capacity in both experimental models and clinical subjects by using spirometric gating CT. CT density histogram was obtained from CT image which was produced by using the developed software for this purpose. Densitometric parameters, such as mean CT value, %LAA, the peak in the histogram and 5% tile were selected from CT image. Papain solution of 5 mg/kg body weight was cumulatively administered to the left lower lobe in canine lung, resulting in the destruction of lung alveolar walls in parallel to the increasing dosage of papain. There was a significant correlation between not only the increasing dosage of papain, but also %FEV 1.0 and CT densitometric parameters, indicating that the histological changes of alveolar walls and the lung function in lung emphysema could be estimated by analysis of CT image. These experimental and clinical studies suggest that the analysis of CT image can reflect the pathophysiological changes in the lung and be useful for precise clinical diagnosis of lung emphysema. (author)

  11. Fatty liver: prospective comparative study with sonography and CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kim, Y. M.; Kim, W. S.; Choi, B. I.; Lee, J. S.; Han, C. K.; Kim, C. W.

    1990-01-01

    To identify the reasonable criteria in detection of the degree of Fatty liver, we prospectively evaluated sonograms and CT scans in 33 Patients With bright liver on sonography. On sonograms, we analyzed the echogenicity of the liver, acoustic attenuation, and visualization of the portal vein and the diaphragm, Each criterion was scored from 0 to 2. CT criterion for fatty liver was assessed by the attenuation difference between the liver and the spleen on nonocontrast CT scans, The average sonographic grade for CT Grade I was 1.3, Grade II was 2.1,and Grade III was 2.8. The accurate detection rate of each sonographic grade was as follows, Grade

  12. Morphologic and Morphometric Analysis of Lingula in Localizing Mandibular Foramen with its Surgical Importance

    Directory of Open Access Journals (Sweden)

    Phalguni Srimani

    2017-10-01

    Full Text Available Introduction: Morphologic and morphometric evaluation of mandible is clinically important. Considering the close relationship of lingula with neurovascular structures entering through mandibular foramen, lingula is often used as an important bony landmark during oral and maxillofacial surgical approach and inferior alveolar nerve block anaesthesia. Inadequate anatomical knowledge may result various intra operative complications like haemorrhge, fractures and nerve injury. Also, structural variations of lingula followed by inaccurate localization of mandibular foramen have been implicated as causative factor for unsuccessful inferior alveolar nerve block anaesthesia. Aim: To determine morphological and morphometric variations related to lingula of mandible in localizing mandibular foramen and to compare the results with similar type of osteological studies performed earlier on different population group. Materials and Methods: The study was performed on 36 adult dry human mandibles on both sides to categorize lingula according to its various shapes and determine the location of lingula based on surrounding mandibular landmarks by using Vernier caliper as 5 distances from tip of lingula as follows: i to anterior border of ramus of mandible; ii to posterior border of ramus of mandible; iii to centre of mandibular notch; iv to the alveolar socket of second molar tooth; and v to the base of mandible. The present study also indicated bilingual distance between tips of lingula of both sides. Data collected were analyzed statistically. Results: The most common shape of lingula was observed as triangular (51.39% followed by truncated (23.61%, then nodular (20.83% and assimilated (4.17% as least prevalent type. The average distances of tip of lingula from anterior and posterior borders of ramus of mandible were 18.21±1.50 mm and 16.33±1.21 mm respectively. On average, the tip of lingula was situated at 18.17±1.51 mm, 33.40±2.11 mm and 32.07±2.68 mm

  13. Anatomic Variation in Morphometry of Human Coracoid Process among Asian Population

    Directory of Open Access Journals (Sweden)

    Manal Fathi

    2017-01-01

    Full Text Available Ethnic origin plays an important role in bone morphometry. Studies examining the influence of coracoid process have focused primarily on adults and have not included people from diverse Asian ethnic backgrounds. Our goal was to explore ethnic differences in morphometry of coracoid among Asian population. We performed morphometric measurements of coracoid process on cadaveric shoulders and shoulder CT scans from 118 specimens. The cadaveric sample included Indian (46%, Chinese (27%, and Myanmarese (27% subjects, while the CT scans sample included Chinese (67% and Malay (33% subjects. The morphometric measurements were performed using digital caliper and software developed at Golden Horses Health Sanctuary (GHHS. In the Indian cadaveric shoulders, the coracoid process is better developed than the other groups with the exception of the tip width of coracoid process. There are significant differences in almost all measurements (P<0.05 between the ethnic groups. On the other hand, the morphometry of coracoid process from CT scans data is bigger in Chinese than Malay subjects when stratified by sex (P<0.05. Moreover, in all morphometric measurements, the females had smaller measurements than males (P<0.05. Understanding such differences is important in anatomy, forensic and biological identity, and orthopaedic and shoulder surgeries.

  14. A study of requested CT head examinations and their positive yield rate

    International Nuclear Information System (INIS)

    Coakley, K.S.

    2004-01-01

    Full text: Requests for CT examinations are ever increasing, partly due to the excellent clinical information they can provide for patient management and partly due to a perceived need for 'evidence' that everything has been done to diagnose a patient correctly. This has led to many CT examinations being done on patients where many of the radiology community does not necessarily feel CT will yield a positive finding, i.e. in their eyes - a possible unjustified use of radiation. To determine whether this was in fact true, or merely a perception, a study was performed by medical imaging and physics staff at the Royal Brisbane Hospital to determine statistics of positive yield for CT head exams. 600 CT head examinations from the Emergency Department at the Royal Brisbane Hospital were retrospectively examined and their findings were tabulated under various clinical categories to determine positive yield statistics. These categories were also tabulated with the radiologists advice as to whether they would have expected a positive finding. For several categories the positive yield for CT head exams was so low as to be considered negligible. Other categories, although low were still considered significant. These will be presented to the emergency department along with a suggested protocol for requesting CT head exams. It was unfortunate that this study had to be performed to prove to clinical staff that medical imaging staff members do in general have an excellent idea of what will show up in an x-ray and what will not! However, it was useful to be able to categorise 'positive yield' statistics into such specific classes. The next step is to try and communicate these findings to staff to create more trust and better communication between departments. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  15. Child gluteal aggressive fibromatosis: a correlative study of CT findings and pathology

    International Nuclear Information System (INIS)

    Fan Miao; Li Ziping; Meng Quanfei; Guo Yan; Ye Bingbing; Xiao Gang

    2005-01-01

    Objective: To evaluate CT imaging in the diagnosis of child gluteal aggressive fibromatosis. Methods: CT manifestations of child gluteal aggressive fibromatosis were retrospectively analyzed. In total 7 males and 1 female, 2 to 11 years old, were enrolled in study. All cases had been confirmed by surgery and pathology. CT findings were correlatively studied with pathology. Results: Lesions located on the left side were noted in 7 cases, and a lesion located on right side was seen in the rest 1 cam The lesions were elliptical or lobulated on CT images. Three tumors originated from solitary muscle and multiple muscles were involved in other 5 cases. Tumors were well demarcated. Invasion to the adjacent structure was shown in 7 cases. All tumors were homogeneous in density in non-enhanced scan. Compared to the muscles in the same section, 5 tumors were iso -density and 3 tumors were hypo-density. Inside the lesions no hemorrhage, necrosis, cystic degeneration and calcification was revealed. After contrast medium was administrated, iso-dense and homogeneous enhancement as the adjacent muscles was seen in 1 tumor and apparent enhancement were demonstrated in 7 tumors. Seven tumors tended to grow along the longitudinal axis of muscles and infiltrated into fascial space. Atrophy resulting from compression was shown in the adjacent muscles in 6 cases. The major clinical manifestation was limp. Gluteal aggressive fibromatosis was confirmed by pathology in all cases. Conclusion: There are characteristics of child gluteal aggressive fibromatosis in age of onset, gender of the patients, site of the lesion and CT findings as well. CT manifestations were consistent with pathology. CT imaging is helpful in initial diagnosis and differential diagnosis, as well as in assessing the expansion of the tumor and involvement of the adjacent structures. (authors)

  16. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  17. Exploring Eucladoceros ecomorphology using geometric morphometrics.

    Science.gov (United States)

    Curran, Sabrina C

    2015-01-01

    An increasingly common method for reconstructing paleoenvironmental parameters of hominin sites is ecological functional morphology (ecomorphology). This study provides a geometric morphometric study of cervid rearlimb morphology as it relates to phylogeny, size, and ecomorphology. These methods are then applied to an extinct Pleistocene cervid, Eucladoceros, which is found in some of the earliest hominin-occupied sites in Eurasia. Variation in cervid postcranial functional morphology associated with different habitats can be summarized as trade-offs between joint stability versus mobility and rapid movement versus power-generation. Cervids in open habitats emphasize limb stability to avoid joint dislocation during rapid flight from predators. Closed-adapted cervids require more joint mobility to rapidly switch directions in complex habitats. Two skeletal features (of the tibia and calcaneus) have significant phylogenetic signals, while two (the femur and third phalanx) do not. Additionally, morphology of two of these features (tibia and third phalanx) were correlated with body size. For the tibial analysis (but not the third phalanx) this correlation was ameliorated when phylogeny was taken into account. Eucladoceros specimens from France and Romania fall on the more open side of the habitat continuum, a result that is at odds with reconstructions of their diet as browsers, suggesting that they may have had a behavioral regime unlike any extant cervid. © 2014 Wiley Periodicals, Inc.

  18. Morphometric evaluation of AgNORs in odontogenic cysts.

    Science.gov (United States)

    Sreeshyla, Huchanahalli S; Shashidara, Raju; Sudheendra, Udyavara Sridhara

    2013-10-01

    To evaluate the morphometry of AgNORs in odontogenic cysts and to compare their biologic behavior to determine whether AgNOR morphometry is helpful in predicting the behavior. Ten cases each of odontogenic keratocyst (OKC), dentigerous cyst (DC) and radicular cyst (RC) were stained with silver nitrate. Morphometric analysis of 100 selected epithelial and connective tissue cells was done to record their nuclear volume, nuclear perimeter, contour index of the nucleus, AgNOR count, AgNOR proportion and single AgNOR volume. The results were statistically analyzed using ANOVA. AgNOR count, nuclear volume and nuclear perimeter were greatest in the OKC followed by DC and RC, suggesting that these parameters differentiate between the aggressive and less aggressive odontogenic cysts. Single AgNOR volume and AgNOR proportion were greatest in the RC followed by OKC and DC, respectively. Results of our study taken in isolation point to AgNOR count as the most reliable factor in differentiating between aggressive and nonaggressive odontogenic cysts.

  19. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  20. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  1. CT study of the ethmoid labyrinth: technique of examination and normal anatomy

    International Nuclear Information System (INIS)

    Duvoisin, B.; Schnyder, P.; Chapuis, L.; Agrifoglio, A.; Krayenbuehl, M.

    1990-01-01

    These recent years, conservative endoscopic surgical treatments for inflammatory ethmoid disease have gained popularity and prompted a need for an optimal preoperative radiologic study. For this purpose, the routinely used axial and coronal CT slices are not sufficient. In our Center, the ethmoid labyrinth is studied with planes determined by the axis of drainage of all ethmoid cells. This axis corresponds to the axis of the nasofrontal duct, which is approximately angulated 50 sup(0) cephalad relative to the canto-meatal line (CML). We perform routinely CT sections in the planes CML sup(+) and CML -40 (which are respectively parallel and perpendicular to the nasofrontal duct axis). The normal anatomy of the ethmoid labyrinth is illustrated by sequential CT slices in these two planes. (author)

  2. Morphometrical differences between resectable and non-resectable pancreatic cancer: a fractal analysis.

    Science.gov (United States)

    Vasilescu, Catalin; Giza, Dana Elena; Petrisor, Petre; Dobrescu, Radu; Popescu, Irinel; Herlea, Vlad

    2012-01-01

    Pancreatic cancer is a highly aggressive cancer with a rising incidence and poor prognosis despite active surgical treatment. Candidates for surgical resection should be carefully selected. In order to avoid unnecessary laparotomy it is useful to identify reliable factors that may predict resectability. Nuclear morphometry and fractal dimension of pancreatic nuclear features could provide important preoperative information in assessing pancreas resectability. Sixty-one patients diagnosed with pancreatic cancer were enrolled in this retrospective study between 2003 and 2005. Patients were divided into two groups: one resectable cancer group and one with non-resectable pancreatic cancer. Morphometric parameters measured were: nuclear area, length of minor axis and length of major axis. Nuclear shape and chromatin distribution of the pancreatic tumor cells were both estimated using fractal dimension. Morphometric measurements have shown significant differences between the nuclear area of the resectable group and the non-resectable group (61.9 ± 19.8µm vs. 42.2 ± 15.6µm). Fractal dimension of the nuclear outlines and chromatin distribution was found to have a higher value in the non-resectable group (p<0.05). Objective measurements should be performed to improve risk assessment and therapeutic decisions in pancreatic cancer. Nuclear morphometry of the pancreatic nuclear features can provide important pre-operative information in resectability assessment. The fractal dimension of the nuclear shape and chromatin distribution may be considered a new promising adjunctive tool for conventional pathological analysis.

  3. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  4. Morphometric and functional alterations of amygdale and hippocampus in patients with depression: a MRI study

    International Nuclear Information System (INIS)

    Wang Dongqing; Li Yuefeng; Luo Yifeng

    2011-01-01

    Objective: To explore the morphometric and functional alterations of amygdale and hippocampus in patients with depression by anatomical and functional MRI, and try to reveal the pattern and pathogenesis of the changes in depression. Methods: Sixty patients (divided equally into mild, moderate and major groups according to patient's scores of HAMD) and 20 healthy control groups were scanned using T 1 WI and fMRI. The outlines of hippocampus and amygdale were drawn manually by observer and the volumes were calculated and normalized subsequently. Functional MRI was processed using SPM5 and individual activation map was got subsequently. Dunnett-t test and Pearson correlation analysis were separately used to analyze the morphometric and functional changes and the correlations between cerebral changes and clinical severity. Results: The hippocampal volumes of control groups were 2296±202 left for left side and 2283±199 for right side. The hippocampal volumes of depressive patients were smaller than those of control groups, especially for the major group (left 1978±176, Dunnett-t =-10.0, P 0.05, right 2210±191, Dunnett-t =-1.6, P>0.05). The amygdale's volumes of control groups was 1762±185, the right was 1749±182, while those in patient group reduced along with the patient's condition, i. e., the mild groups (left 1992±200, Dunnett-t =4.8, P<0.01, right 1989±191, Dunnett-t =5.0, P<0.001), the moderate groups (left 1889±192, Dunnett-t =2.8, P<0.05, right 1896±195, Dunnett-t =2.8, P<0.05), and the major groups (left 1539±178, Dunnett-t =-6.8, P<0.01, right 1543±180, Dunnett-t =-7.0, P< 0.01). For fMRI study, patient group demonstrated more activation of the amygdale and hippocampus under the stimulations of negative images than controls. Furthermore, the strengthens of activation decreased along with the patient's condition, i. e., the major ones showed the weakest activation among the patients, though it was higher than that of control group. In patient group

  5. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  6. Study of CT head scans using different voltages: image quality evaluation

    International Nuclear Information System (INIS)

    Pacheco de Freitas C, I.; Prata M, A.; Alonso, T. C.; Santana, P.

    2016-10-01

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  7. The problem of assessing landmark error in geometric morphometrics: theory, methods, and modifications.

    Science.gov (United States)

    von Cramon-Taubadel, Noreen; Frazier, Brenda C; Lahr, Marta Mirazón

    2007-09-01

    Geometric morphometric methods rely on the accurate identification and quantification of landmarks on biological specimens. As in any empirical analysis, the assessment of inter- and intra-observer error is desirable. A review of methods currently being employed to assess measurement error in geometric morphometrics was conducted and three general approaches to the problem were identified. One such approach employs Generalized Procrustes Analysis to superimpose repeatedly digitized landmark configurations, thereby establishing whether repeat measures fall within an acceptable range of variation. The potential problem of this error assessment method (the "Pinocchio effect") is demonstrated and its effect on error studies discussed. An alternative approach involves employing Euclidean distances between the configuration centroid and repeat measures of a landmark to assess the relative repeatability of individual landmarks. This method is also potentially problematic as the inherent geometric properties of the specimen can result in misleading estimates of measurement error. A third approach involved the repeated digitization of landmarks with the specimen held in a constant orientation to assess individual landmark precision. This latter approach is an ideal method for assessing individual landmark precision, but is restrictive in that it does not allow for the incorporation of instrumentally defined or Type III landmarks. Hence, a revised method for assessing landmark error is proposed and described with the aid of worked empirical examples. (c) 2007 Wiley-Liss, Inc.

  8. Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

    DEFF Research Database (Denmark)

    Zheng, Yi; Yang, Yan; Rogowska, M.

    2017-01-01

    to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection....... The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales...... of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk....

  9. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  10. Morphometrical Study of the Temporal Bone and Auditory Ossicles in Guinea Pig

    Directory of Open Access Journals (Sweden)

    Ahmadali Mohammadpour

    2011-03-01

    Full Text Available In this research, anatomical descriptions of the structure of the temporal bone and auditory ossicles have been performed based on dissection of ten guinea pigs. The results showed that, in guinea pig temporal bone was similar to other animals and had three parts; squamous, tympanic and petrous .The tympanic part was much better developed and consisted of oval shaped tympanic bulla with many recesses in tympanic cavity. The auditory ossicles of guinea pig concluded of three small bones; malleus, incus and stapes but the head of the malleus and the body of incus were fused and forming a malleoincudal complex. The average of morphometric parameters showed that the malleus was 3.53 ± 0.22 mm in total length. In addition to head and handle, the malleus had two distinct process; lateral and muscular. The incus had a total length 1.23 ± 0.02mm. It had long and short crus although the long crus was developed better than short crus. The lenticular bone was a round bone that articulated with the long crus of incus. The stapes had a total length 1.38 ± 0.04mm. The anterior crus(0.86 ± 0.08mm was larger than posterior crus (0.76 ± 0.08mm. It is concluded that, in the guinea pig, the malleus and the incus are fused, forming a junction called incus-malleus, while in the other animals these are separate bones. The stapes is larger and has a triangular shape and the anterior and posterior crus are thicker than other rodents. Therefore, for otological studies, the guinea pig is a good lab animal.

  11. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the

  12. Morphometric differences and fluctuating asymmetry in Melipona subnitida Ducke 1910 (Hymenoptera: Apidae in different types of housing

    Directory of Open Access Journals (Sweden)

    C. B. S. Lima

    Full Text Available Abstract A geometric morphometrics approach was applied to evaluate differences in forewing patterns of the Jandaira bee (Melipona subnitida Ducke. For this, we studied the presence of fluctuating asymmetry (FA in forewing shape and size of colonies kept in either rational hive boxes or natural tree trunks. We detected significant FA for wing size as well as wing shape independent of the type of housing (rational box or tree trunks, indicating the overall presence of stress during the development of the studied specimens. FA was also significant (p < 0.01 between rational boxes, possibly related to the use of various models of rational boxes used for keeping stingless bees. In addition, a Principal Component Analysis indicated morphometric variation between bee colonies kept in either rational hive boxes or in tree trunks, that may be related to the different origins of the bees: tree trunk colonies were relocated natural colonies while rational box colonies originated from multiplying other colonies. We conclude that adequate measures should be taken to reduce the amount of stress during bee handling by using standard models of rational boxes that cause the least disruption.

  13. Morphometric differences and fluctuating asymmetry in Melipona subnitida Ducke 1910 (Hymenoptera: Apidae) in different types of housing.

    Science.gov (United States)

    Lima, C B S; Nunes, L A; Carvalho, C A L; Ribeiro, M F; Souza, B A; Silva, C S B

    2016-01-01

    A geometric morphometrics approach was applied to evaluate differences in forewing patterns of the Jandaira bee (Melipona subnitida Ducke). For this, we studied the presence of fluctuating asymmetry (FA) in forewing shape and size of colonies kept in either rational hive boxes or natural tree trunks. We detected significant FA for wing size as well as wing shape independent of the type of housing (rational box or tree trunks), indicating the overall presence of stress during the development of the studied specimens. FA was also significant (p < 0.01) between rational boxes, possibly related to the use of various models of rational boxes used for keeping stingless bees. In addition, a Principal Component Analysis indicated morphometric variation between bee colonies kept in either rational hive boxes or in tree trunks, that may be related to the different origins of the bees: tree trunk colonies were relocated natural colonies while rational box colonies originated from multiplying other colonies. We conclude that adequate measures should be taken to reduce the amount of stress during bee handling by using standard models of rational boxes that cause the least disruption.

  14. An experimental study for qualitatively diagnosing stapes lesions by helical 3-dimensional CT

    International Nuclear Information System (INIS)

    Kawaue, Akifumi; Kuki, Kiyonori; Yamanaka, Noboru; Nishimura, Michihiko

    2001-01-01

    To evaluate qualitative diagnosis of stapes lesions by 3-dimensional computed tomography (3D-CT) combined with superselective image processing (3D-SS) of stapes, we studied helical 3D-CT on a phantom model of the temporal bone. Two stapes models were used-1 made from the bone filler, Celatite, consistent in bone density but changing in cross sectional area, and the other made from an apacerum rod used in quantitative computed tomography (QCT), consistent in cross sectional area but changing in bone density. These stapes models were put into a skull phantom and analyzed by helical 3D-CT. The influence of the tympanic cavity conditions on CT images of stapes was evaluated by filling the phantom model with Vaseline following 3D selective reconstruction. In all stapes models, lowering the lower CT window width threshold resulted in an enlarged cross-sectional area of the model. The higher the bone density, the lower the increase in cross-sectional area in the image. The stapes model with lower density had greater influence on the imaging by tympanic cavity conditions and was likely to be misdiagnosed as showing higher bone density. Based on the experimental study, 3D-SS by helical 3D-CT appears to be a useful measure for qualitatively diagnosing stapes lesions. (author)

  15. MORPHOMETRIC STUDY OF MEDIAL COLLATERAL LIGAMENTS OF ANKLE

    Directory of Open Access Journals (Sweden)

    Neelu Prasad

    2016-06-01

    is very poorly understood. The ligament in case of tear or injury has to be repaired which is impossible to do so if a proper morphometric knowledge is not known. So a sincere effort has been put in the study to find the morphometry of the deltoid ligament. METHODS  One hundred specimens were dissected. In this, fifty belonged to the right and fifty belonged to the left side.  The study was done in the Department of Anatomy, Nalanda Medical College, Patna.  The study was done from June 2015 to April 2016.  The morphometry was seen and the comparisons were done.  The dissection was done to expose the deltoid ligament. The anterior, middle and posterior length was taken. Then, the superior, middle and inferior width was taken. Then, the thickness was measured.  Then, the presence or absence of the deep part was noted. RESULTS Irrespective of the side and sex to which the ligaments belong, the mean value of the length of the deltoid ligaments in the anterior, middle and posterior parts are 24.40 mm, 21.53 mm and 17.20 mm. The widths in the superior, middle and inferior parts are 19.94 mm, 22.59 mm and 27.45 mm. The thickness mean measurement is 6.94 mm. Deep Part was found in 100% of cases. The superficial part trapezoid in shape wide anteriorly and narrow posteriorly, also is narrow superiorly where it arises and broad inferiorly where it gets inserted. CONCLUSION The ligaments of the talocrural joint are one of the most difficult ligaments to study. A sincere effort has been put in this study to find the morphometry of ligaments of ankle joint. The same has been studied and reported successfully to help the surgeons to understand and help the needful in a better way.

  16. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  17. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  18. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  19. Clinical utility of FDG PET/CT in acute complicated pyelonephritis - results from an observational study

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Hsing [Mackay Memorial Hospital at Taipei, Department of Nuclear Medicine, Taipei (China); Tseng, Jing-Ren; Yen, Tzu-Chen [Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan (China); Lee, Ming-Hsun [Chang Gung Memorial Hospital at Linkou, Division of Infectious Diseases, Department of Internal Medicine, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou, Biostatistics Unit, Clinical Trial Center, Taoyuan (China)

    2018-03-15

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of {sup 18}F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course. (orig.)

  20. Anterior mediastinal masses in the Framingham Heart Study: Prevalence and CT image characteristics

    International Nuclear Information System (INIS)

    Araki, Tetsuro; Nishino, Mizuki; Gao, Wei; Dupuis, Josée; Washko, George R.; Hunninghake, Gary M.; Murakami, Takamichi; O’Connor, George T.; Hatabu, Hiroto

    2015-01-01

    To investigate the prevalence and CT image characteristics of anterior mediastinal masses in a population-based cohort and their association with the demographics of the participants. Chest CT scans of 2571 Framingham Heart Study participants (mean age 58.9 years, 51% female) were evaluated by two board-certified radiologists with expertise in thoracic imaging for the presence of anterior mediastinal masses, their shape, contour, location, invasion of adjacent structures, fat content, and calcification. For participants with anterior mediastinal masses, a previous cardiac CT scan was reviewed for interval size change of the masses, when available. The demographics of the participants were studied for any association with the presence of anterior mediastinal masses. Of 2571, 23 participants (0.9%, 95% CI: 0.6–1.3) had anterior mediastinal masses on CT. The most common CT characteristics were oval shape, lobular contour, and midline location, showing soft tissue density (median 32.1 HU). Fat content was detected in a few cases (9%, 2/23). Six out of eight masses with available prior cardiac CT scans demonstrated an interval growth over a median period of 6.5 years. No risk factors for anterior mediastinal masses were detected among participants’ demographics, including age, sex, BMI, and cigarette smoking. The prevalence of anterior mediastinal masses is 0.9% in the Framingham Heart Study. Those masses may increase in size when observed over 5–7 years. Investigation of clinical significance in incidentally found anterior mediastinal masses with a longer period of follow-up would be necessary

  1. Morphometric analysis of hepatic steatosis in chronic hepatitis C infection

    International Nuclear Information System (INIS)

    Zubair, Alia; Jamal Shahid; Mubarik Azhar

    2009-01-01

    To quantitatively assess steatosis by a morphometric method and to study its relationship with other histological features of chronic hepatitis C (CHC). This was a comparative descriptive study. The study was carried out in the Department of Histopathology, Army Medical College, Rawalpindi, Pakistan, from March 2006 to March 2007. Patients who had undergone a liver biopsy for the evaluation of hepatitis C virus (HCV) infection were included in the study. Demographic characteristics and laboratory data were collected at the time of biopsy. The first hundred biopsy specimens that met the inclusion criteria were assessed for grades of steatosis (semiquantitatively), diameter of fat globules (by a morphometric method), necroinflammation, and fibrosis (semiquantitatively). Liver biopsies were processed for paraffin embedding, stained with hematoxylin and eosin, whereas Gomori's Reticulin stain was used for the evaluation of fibrosis. Out of 46 cases showing fatty change, pansteatosis was observed in 24 (52%) patients: 12 (26%) cases had a pericentral and mid zonal distribution of fat globules and eight (17.5%) cases revealed a mid zonal pattern only. There were two (4.5%) cases in which fat globules were found in periportal and mid zonal areas. None of the histological parameters (the stage of fibrosis and grades of inflammation) had any significant correlation with these distribution patterns of steatosis. The diameter of fat droplets was quantified by morphometry. A mixed pattern of steatosis was observed more frequently (21 out of 46 cases): 17 cases had microglobules and eight biopsies showed macroglobules. The size of the fat globules exhibited a significant correlation with the stage of fibrosis ( P < 0.0001). The analysis of the grades of necroinflammation did not reveal any significant relationship with the diameter of fat globules. A mixed pattern of fat globules is more frequently observed in CHC, but macrovesicular steatosis is associated with a higher stage

  2. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  3. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  4. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  5. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  6. Anatomic Variation in Morphometry of Human Coracoid Process among Asian Population.

    Science.gov (United States)

    Fathi, Manal; Cheah, Pike-See; Ahmad, Umar; Nasir, M Nizlan; San, Aye Aye; Abdul Rahim, Ezamin; Hussin, Paisal; Mahmud, Rozi; Othman, Fauziah

    2017-01-01

    Ethnic origin plays an important role in bone morphometry. Studies examining the influence of coracoid process have focused primarily on adults and have not included people from diverse Asian ethnic backgrounds. Our goal was to explore ethnic differences in morphometry of coracoid among Asian population. We performed morphometric measurements of coracoid process on cadaveric shoulders and shoulder CT scans from 118 specimens. The cadaveric sample included Indian (46%), Chinese (27%), and Myanmarese (27%) subjects, while the CT scans sample included Chinese (67%) and Malay (33%) subjects. The morphometric measurements were performed using digital caliper and software developed at Golden Horses Health Sanctuary (GHHS). In the Indian cadaveric shoulders, the coracoid process is better developed than the other groups with the exception of the tip width of coracoid process. There are significant differences in almost all measurements ( P Chinese than Malay subjects when stratified by sex ( P < 0.05). Moreover, in all morphometric measurements, the females had smaller measurements than males ( P < 0.05). Understanding such differences is important in anatomy, forensic and biological identity, and orthopaedic and shoulder surgeries.

  7. Effect of Chang Run Tong on the Biomechanical and Morphometric Remodeling of Colon and Rectum in STZ Induced Diabetic Rats

    DEFF Research Database (Denmark)

    Sha, Hong; Zhao, Dong; Zhao, Jingbo

    2013-01-01

    The present study investigates the effect of Chang Run Tong (CRT) on the biomechanical and morphometrical remodeling of colon and rectum in streptozotocin-induced diabetic rats. The colonic and rectal segments were obtained from diabetic (DM), CRT-treated diabetic (T1, high dosage: 50 g/kg/day; T2...

  8. Comparative study on developmental stages of the clavicle by postmortem MRI and CT imaging

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels; Jensen, K.E.

    2013-01-01

    Objectives: The developmental stages of the clavicles are important for forensic age estimation purposes in adolescents. This study compares the 4-stage system to evaluate the ossification of the medial end of the clavicle as visualized by magnetic resonance imaging (MRI) and computed tomography...... (CT). As several forensic institutes routinely perform CT scans, the large amount of available data may serve as reference sample for MRI in specific cases. Material and methods: This prospective study included an MRI and CT scan of 47 autopsy cases performed prior to medico-legal autopsy (age range...

  9. Basic studies of CT in the maxillofacial areas, 1

    International Nuclear Information System (INIS)

    Suzuki, Shinichiro; Kaneko, Hiroshi; Higashi, Tomomitsu; Takenaka, Eiichi.

    1982-01-01

    As CT values of hard tissues would pose problems in the application of CT to the maxillofacial area, attenuation coefficients of each oral hard tissue were examined based on the existing data, and the linearity in the area of high x-ray attenuation was examined. We thought that a new contrast scale suitable for each area should be established for measurements of CT values of tissues of high x-ray attenuation such as teeth. (Chiba, N.)

  10. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  11. Stroke Pattern in Enugu. A Study of CT images in South East Nigeria ...

    African Journals Online (AJOL)

    Non-contrast cranial computed tomography (CT) scan reliably distinguishes between ischemic stroke (IS) and hemorrhagic strokes (HS) and will provide a reliable characterization of stroke types in the developing countries. Aims: To examine stroke types based on CT Imaging studies and the differences in stroke types ...

  12. CT-guided radiolabelled aerosol studies for assessing pulmonary impairment in children with bronchiectasis

    International Nuclear Information System (INIS)

    Pifferi, M.; Baldini, M.; Caramella, D.; Bartolozzi, C.; Di Mauro, M.; Cangiotti, A.M.

    2000-01-01

    Objective. To determine whether CT-guided mucociliary clearance studies allow differentiation between bronchiectasis associated with primary ciliary dyskinesia (PCD) and those unrelated to congenital or genetically transmitted defects. Materials and methods. Fifteen children aged 4-18 years with a CT diagnosis of bronchiectasis were included in the study. Six had PCD, while in nine cases no congenital disorder was demonstrated. Results. CT showed bronchiectasis in 26 (29 %) of 90 lung regions. Radiolabelled aerosol studies were conducted globally for each lung and on the regions affected by bronchiectasis. Global half-time of activity (t 1/2 ) values of patients with PCD were significantly higher (P 1/2 values. Patients with bronchiectasis unrelated to congenital disorders showed significantly higher regional t 1/2 values in the affected regions with respect to the corresponding global pulmonary t 1/2 (P < 0.06). Conclusions. The combination of morphological CT information with functional data concerning the clearance of radiolabelled aerosol adds to our understanding of pulmonary impairment in children with bronchiectasis. In particular, regional studies allow the recognition of different mucociliary clearance patterns in bronchiectasis associated with PCD and those unrelated to congenital or genetically transmitted defects. (orig.)

  13. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  14. Variations in otolith patterns, sizes and body morphometrics of jack mackerel Trachurus japonicus juveniles.

    Science.gov (United States)

    Kanaji, Y; Kishida, M; Watanabe, Y; Kawamura, T; Xie, S; Yamashita, Y; Sassa, C; Tsukamoto, Y

    2010-10-01

    Variations in otolith patterns, sizes and body morphometrics of jack mackerel Trachurus japonicus juveniles were investigated. Under transmitted light, translucent (W(t)) and opaque otoliths (W(o)) were detected in juveniles collected from Wakasa Bay between July 2005 and April 2006, whereas only opaque otoliths (G(o)) were detected in Goto-nada Sea individuals between May and June 2006. Three groups of juveniles were distinguished based on differences in hatch season, otolith size and growth history, and body morphometrics. As T. japonicus has different spawning seasons according to spawning grounds, each group was estimated to hatch in different waters. Juveniles with W(t) otoliths were considered to have stayed in coastal habitat longer, as the hatch area was estimated to be near Wakasa Bay. Juveniles with W(o) and G(o) otoliths appear to recruit to coastal waters at larger size, since their hatch areas were estimated to be far from each collection area. Larger otoliths of W(t) were attributed to otolith accretion after the second growth flexion, which was observed only for W(t) . Standard length of W(t) fish at the second otolith growth flexion was estimated to correspond to recruitment size to coastal rocky reefs in Wakasa Bay. Body morphometrics were correlated with otolith size after removing body size effect, suggesting that morphological variations of T. japonicus juveniles were also associated with the timing of recruitment to coastal habitat. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  15. Morphometrics and structure of complete baleen racks in gray whales (Eschrichtius robustus) from the Eastern North Pacific Ocean.

    Science.gov (United States)

    Young, Samantha; DeméRé, Thomas A; Ekdale, Eric G; Berta, Annalisa; Zellmer, Nicholas

    2015-04-01

    Mysticetes have evolved a novel filter feeding apparatus-baleen-an epidermal keratinous tissue composed of keratin that grows as a serial arrangement of transverse cornified laminae from the right and left sides of the palate. The structure and function of baleen varies among extant mysticete clades and this variation likely can be viewed as adaptations related to different filter feeding strategies. In one of the first morphometric studies of the full baleen apparatus, we describe the morphology of complete baleen racks in neonate, yearling and adult gray whales (Eschrichtius robustus), and note morphometric variations between age groups as well as within individual racks. Morphometric data and detailed descriptions were collected from the full baleen apparatus of three frozen specimens of E. robustus using previously derived ecologically significant and broad scale measurements of baleen. Additionally, characters of the baleen apparatus were described based on visible patterns of baleen laminae and plates on the dorsal root of the rack. Results indicate that the longest, widest, and thickest plates and laminae are found toward the posterior half of the rack, resulting in the greatest surface area for filtration of prey occurring in this region. Ontogenetic changes were also documented that reveal a progressive increase in the filter surface area of the developing baleen apparatus as baleen laminae and main plates grow in length and width. Also noted was a progressive posterior shift in the position of greatest filtration area. Histological examination of the epithelial base (Zwischensubstanz) and laminae showed basic epidermal layers, as well as gapping between layers and vacuoles. © 2015 Wiley Periodicals, Inc.

  16. MORPHOMETRIC CHARACTERIZATION OF THE SAND FRACTION IN A SAND GRAIN IMAGE CAPTURE SYSTEM1

    Directory of Open Access Journals (Sweden)

    Lucimar Arruda Viana

    Full Text Available ABSTRACT Morphology studies assume significant importance in analysis of phenomena of granular systems packaging, in particular with a view to the use of the technique of soil stabilization named particle size correction in forest roads. In this context, this study aimed to develop and operationalize a Sand Grain Image Capture System and, hereby, determine the morphological indices of the sand fractions of two sandy soils called João Pinheiro (JP and Cachoeira da Prata (CP. Soil samples, air-dried, were sieved (2.0 mm nominal mesh size for removal of gravels. The materials that passed through the sieve were subjected to dispersion, washing in 0.053 mm nominal mesh size sieve, removal of organic matter and iron oxides to obtain the clean sand fractions. Subsequently, each soil sample was sieved for separation into twelve classes, between the diameters of 0.149 mm and 1.190 mm, using a Rotap shaker. Next, tests were carried out to characterize the morphometric attributes of the twelve classes of sand fractions of the soils studied. For validation of the performance of the Sand Grain Image Capture System, the results were compared to those obtained using a standard procedure for image analysis. The analysis of the results led to the following conclusions: (i the sand fraction of the JP soil presented higher values for the morphometric indices roundness, elongation and compactness compared to sand fraction of the CP soil; and (ii the Sand Grain Image Capture System worked properly, with practicality.

  17. Unveiling the neurotoxicity of methylmercury in fish (Diplodus sargus) through a regional morphometric analysis of brain and swimming behavior assessment.

    Science.gov (United States)

    Puga, Sónia; Pereira, Patrícia; Pinto-Ribeiro, Filipa; O'Driscoll, Nelson J; Mann, Erin; Barata, Marisa; Pousão-Ferreira, Pedro; Canário, João; Almeida, Armando; Pacheco, Mário

    2016-11-01

    The current study aims to shed light on the neurotoxicity of MeHg in fish (white seabream - Diplodus sargus) by the combined assessment of: (i) MeHg toxicokinetics in the brain, (ii) brain morphometry (volume and number of neurons plus glial cells in specific brain regions) and (iii) fish swimming behavior (endpoints associated with the motor performance and the fear/anxiety-like status). Fish were surveyed for all the components after 7 (E7) and 14 (E14) days of dietary exposure to MeHg (8.7μgg -1 ), as well as after a post-exposure period of 28days (PE28). MeHg was accumulated in the brain of D. sargus after a short time (E7) and reached a maximum at the end of the exposure period (E14), suggesting an efficient transport of this toxicant into fish brain. Divalent inorganic Hg was also detected in fish brain along the experiment (indicating demethylation reactions), although levels were 100-200 times lower than MeHg, which pinpoints the organic counterpart as the great liable for the recorded effects. In this regard, a decreased number of cells in medial pallium and optic tectum, as well as an increased hypothalamic volume, occurred at E7. Such morphometric alterations were followed by an impairment of fish motor condition as evidenced by a decrease in the total swimming time, while the fear/anxiety-like status was not altered. Moreover, at E14 fish swam a greater distance, although no morphometric alterations were found in any of the brain areas, probably due to compensatory mechanisms. Additionally, although MeHg decreased almost two-fold in the brain during post-exposure, the levels were still high and led to a loss of cells in the optic tectum at PE28. This is an interesting result that highlights the optic tectum as particularly vulnerable to MeHg exposure in fish. Despite the morphometric alterations reported in the optic tectum at PE28, no significant changes were found in fish behavior. Globally, the effects of MeHg followed a multiphasic profile, where

  18. Morphometric changes of whole brain in patients with alcohol addiction: a voxel-based morphometry study

    International Nuclear Information System (INIS)

    Li Jinfeng; Chen Zhiye; Ma Lin

    2011-01-01

    Objective: To evaluate morphometric changes of brain in patients with alcohol addiction by voxel-based morphometry. Methods: Fifteen patients with alcohol addiction and 15 health controls were recruited and underwent fluid attenuated inversion recovery (FLAIR) and 3D fast spoiled gradient echo (FSPGR) T 1 -weighted sequences on a 3.0 T MRI system. 3D FSPGR T 1 structure images were normalized, segmented and smoothed, and then underwent voxel-based morphometry. An ANCOVA was applied with age, body mass index (BMI), and education years as covariates because of exact sex match. A statistical threshold of P 0.05). Conclusions: Regional gray and white matter atrophy can be the initial changes in patients with alcohol addiction and the frontal region is a relative specific damaged brain region. VBM has a potential value for the detection of subtle brain atrophy in patients with alcohol addiction. (authors)

  19. CT-guided suprascapular nerve blocks: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A. [Department of Medical Imaging, Victoria House Private Hospital, 316 Malvern Road, Prahran 3181, Melbourne, Victoria (Australia)

    2004-05-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean ({+-}SEM) pain score of 7.0 ({+-}0.4) to 3.5 ({+-}0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% ({+-}4.9, P<0.001) and 16.8% ({+-}4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  20. CT-guided suprascapular nerve blocks: a pilot study

    International Nuclear Information System (INIS)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A.

    2004-01-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean (±SEM) pain score of 7.0 (±0.4) to 3.5 (±0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% (±4.9, P<0.001) and 16.8% (±4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  1. 3D automatic exposure control for 64-detector row CT: Radiation dose reduction in chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Atsushi [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Inokawa, Hiroyasu [Toshiba Medical Systems, Ohtawara, Tochigi (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, Kobe, Hyogo (Japan); Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Araki, Tsutomu [Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2011-03-15

    Purpose: The purpose of this study was to determine the utility of three-dimensional (3D) automatic exposure control (AEC) for low-dose CT examination in a chest phantom study. Materials and methods: A chest CT phantom including simulated focal ground-glass opacities (GGOs) and nodules was scanned with a 64-detector row CT with and without AEC. Performance of 3D AEC included changing targeted standard deviations (SDs) of image noise from scout view. To determine the appropriate targeted SD number for identification, the capability of overall identification with the CT protocol adapted to each of the targeted SDs was compared with that obtained with CT without AEC by means of receiver operating characteristic analysis. Results: When targeted SD values equal to or higher than 250 were used, areas under the curve (Azs) of nodule identification with CT protocol using AEC were significantly smaller than that for CT protocol without AEC (p < 0.05). When targeted SD numbers at equal to or more than 180 were adapted, Azs of CT protocol with AEC had significantly smaller than that without AEC (p < 0.05). Conclusion: This phantom study shows 3D AEC is useful for low-dose lung CT examination, and can reduce the radiation dose while maintaining good identification capability and good image quality.

  2. Study of metastatic foci by CT in autopsied lung cancer

    International Nuclear Information System (INIS)

    Koga, Mitsuru; Nobe, Yoshifumi; Fujii, Kyoichi.

    1983-01-01

    The authors reexamined all of the image diagnoses made during whole hospitalization in 11 lung cancer cases with autopsy. Of 39 metastatic foci observed at autopsy in the liver, kidney, pancreas, adrenal and brain, 12 had been diagnosed on transverse CT images before death. Three foci were missed at initial readings. The period from CT to autopsy was less than 3 months for 9 of 12 correctly diagnosed foci. For 13 of 27 foci undetected by CT, CT was conducted more than 3 months before death. (Chiba, N)

  3. Shaping up: a geometric morphometric approach to assemblage ecomorphology.

    Science.gov (United States)

    Bower, L M; Piller, K R

    2015-09-01

    This study adopts an ecomorphological approach to test the utility of body shape as a predictor of niche relationships among a stream fish assemblage of the Tickfaw River (Lake Pontchartrain Basin) in southeastern Louisiana, U.S.A. To examine the potential influence of evolutionary constraints, analyses were performed with and without the influence of phylogeny. Fish assemblages were sampled throughout the year, and ecological data (habitat and tropic guild) and body shape (geometric morphometric) data were collected for each fish specimen. Multivariate analyses were performed to examine relationships and differences between body shape and ecological data. Results indicate that a relationship exists between body shape and trophic guild as well as flow regime, but no significant correlation between body shape and substratum was found. Body shape was a reliable indicator of position within assemblage niche space. © 2015 The Fisheries Society of the British Isles.

  4. A clinical study of mucin producing tumor of pancreas with US and CT

    International Nuclear Information System (INIS)

    Suzuki, Tadashi; Imaizumi, Toshihide; Nakasako, Toshiaki; Hatori, Takashi; Takasaki, Ken

    1999-01-01

    We conclude that multilocular cysts are 3 cm and over, or elevated types as in mucin producing pancreatic tumors must be neoplasm in the pathological study. But, we question whether or not we can diagnose the elevated type before the operation. So, for the purpose of making a clear guideline of diagnosis for elevated types, we examined 46 operating cases of mucin producing tumors (Kuroda type I) documented from 1985 to 1994. We examined existence, height and properties of elevated lesions, 25 cases of elevated type and 21 cases of flat type. There is a significant difference of height with US and CT, and existence of enhancement with CT. As a result, we have obtained the following guidelines. The height of an elevated lesion with US is 4 mm and over, and the height of that with CT is 3 mm and over. It is enhanced with CT. Therefore, we find it possible to diagnose elevated types with US and CT. (author)

  5. Human body mass estimation: a comparison of "morphometric" and "mechanical" methods.

    Science.gov (United States)

    Auerbach, Benjamin M; Ruff, Christopher B

    2004-12-01

    In the past, body mass was reconstructed from hominin skeletal remains using both "mechanical" methods which rely on the support of body mass by weight-bearing skeletal elements, and "morphometric" methods which reconstruct body mass through direct assessment of body size and shape. A previous comparison of two such techniques, using femoral head breadth (mechanical) and stature and bi-iliac breadth (morphometric), indicated a good general correspondence between them (Ruff et al. [1997] Nature 387:173-176). However, the two techniques were never systematically compared across a large group of modern humans of diverse body form. This study incorporates skeletal measures taken from 1,173 Holocene adult individuals, representing diverse geographic origins, body sizes, and body shapes. Femoral head breadth, bi-iliac breadth (after pelvic rearticulation), and long bone lengths were measured on each individual. Statures were estimated from long bone lengths using appropriate reference samples. Body masses were calculated using three available femoral head breadth (FH) formulae and the stature/bi-iliac breadth (STBIB) formula, and compared. All methods yielded similar results. Correlations between FH estimates and STBIB estimates are 0.74-0.81. Slight differences in results between the three FH estimates can be attributed to sampling differences in the original reference samples, and in particular, the body-size ranges included in those samples. There is no evidence for systematic differences in results due to differences in body proportions. Since the STBIB method was validated on other samples, and the FH methods produced similar estimates, this argues that either may be applied to skeletal remains with some confidence. 2004 Wiley-Liss, Inc.

  6. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  7. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Study of needles morphometric indexes in Scots pine trees in 25 years after the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Makarenko, E.S. [Russian Institute of Agricultural Radiology and Agroecology, 249030, Obninsk, Russia, Kievskoe shosse 109 km (Russian Federation); Oudalova, A.A. [Russian Institute of Agricultural Radiology and Agroecology, 249030, Obninsk, Russia, Kievskoe shosse 109 km (Russian Federation); Obninsk Institute of Nuclear Power Engineering, National Research Nuclear University MEPhI, 249032, Obninsk, Russia, Studgorodok, 1 (Russian Federation)

    2014-07-01

    Long-term observations of coniferous tree populations within areas contaminated after radiation accidents provide unique information on biological consequences in plant populations from chronic radiation exposure. Many studies have been performed in a near zone of the Chernobyl NPP where in the primary period after the accident non-human biota was exposed to high doses, and dose rates essentially exceed natural radiation background up to now. Of special interest, however, are biological effects in plant and animal populations inhabiting territories with less pronounced exposure levels. Pine is especially important species for investigation in the field of environment radiation protection since it is included in the ICRP reference plants and animals list as one of the most radiosensitive plant species. The aim of this work was to estimate biological effects of chronic radiation impact for pine trees using needle indexes as test-functions. Study-sites are situated in the Bryansk Region of Russia contaminated after the Chernobyl accident. Scots pine populations under study have been growing in the radioactively contaminated areas over 20 years. In 2011 and 2013 samples of 2-years old needle were collected at 6 study-sites. {sup 137}Cs activities in soils at the time of sampling were from 1.57 to 96.9 kBq/kg. Estimated annual doses to pine tree crowns were calculated in a range of 7-130 mGy. Length and weight of the needles were measured, and necrosis rank was determined. Developmental disturbances were estimated via indexes of fluctuating asymmetry calculation for length (FA{sub L}) and weight (FA{sub W}) characteristics. Needle length of the Scots pine from study-sites ranged from 64.8 to 80.2 mm. Needle weight ranged from 18.2 to 30.5 mg, and was higher at radioactively contaminated sites in comparison to reference populations. Correlation of morphometric parameters and radiation impact was, however, statistically insignificant. Normal needle appeared with frequency

  9. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  10. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  11. Application of artificial neural networks in the CT study of solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Wang Xiaohua; Ma Daqing; Chen Hui; Gao Peiyi; Zhou Xinhua

    2006-01-01

    Objective: To establish a new-type discriminative method in differentiating benign from malignant solitary pulmonary nodule (SPN) on high-resolution CT/thin-section CT by using artificial neural networks theory in the CT diagnostic study of SPN. Methods: Two hundred SPNs pathologically proved by operation or biopsy (primary pulmonary carcinoma 135 eases, benign nodules 65 cases) were collected, 3 clinical characteristics (age, sex, with or without bloody sputum) and 9 high-resolution CT/thin-section CT characteristics (location, long and short diameter, contour, spiculation, halo sign, air-space, relation with the adjacent blood vessels and pleura) were analyzed. 140 cases were randomly selected to form the training samples, on which artificial neural networks model (BP networks) was built and compared with Logistic model from Statistical Package for the Social Science (SPSS) software. Results: The total consistent rate of BP neural networks (98.0%, 196/200) was higher than that of Logistic model (86.0%, 172/200) (P<0.001). Areas under ROC curve were 0.996±0.004 and 0.936±0.017, respectively, and the difference between the two was significant (P<0.001). Conclusion: Using high-resolution CT and thin-section CT in combination with artificial neural networks theory is feasible, and it is expected to become a useful and reliable clinical tool in differentiating benign from malignant SPN. (authors)

  12. CT and pathologic studies in detecting hepatic involvement of malignant lymphoma

    International Nuclear Information System (INIS)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1985-01-01

    In order to determine the value of CT in detecting lymphomatous involvement of the liver, 57 autopsied cases (48 cases of non-Hodgkin lymphoma and 9 of Hodgkin's disease) were analyzed in detail. Additionally, 90 recent cases of abdominal CT with liver study in the initial staging were reviewed and 6 cases in which the liver had been examined within 2 weeks before autopsy were compared for macroscopic and pathologic findings. The following results were obtained. 1) Autopsy findings in 57 cases of malignant lymphoma. (1) Hepatic involvement was demonstrated in 56% of the patients with non-Hodgkin lymphoma and in 67% of those with Hodgkin's disease. (2) Of these patients with hepatic involvement, intrahepatic nodular lesions over 1.0cm in diameter were macroscopically identified in 22% of the cases of non-Hodgkin lymphoma and 33% of those with Hodgkin's disease. (3) Lymphomatous involvements were seen in many organs in the cases of hepatic involvement. 2) CT examinations of 90 cases for the initial staging showed no significant abnormality in the liver or spleen. 3) Of the 6 cases in which the liver was examined by CT within about 2 weeks before autopsy, lymphomatous involvemet was pathologically diagnosed in 5. Of these, only one having multiple nodules larger than the tip of a thumb was correctly diagnosed by CT. 4) Hepatic involvement of lymphoma was thought to be the end stage, and minimal or early disease was detected in the region of Glisson's capsule. The above findings indicate that early hepatic involvement is not likely to be detected by CT at the present time. (author)

  13. Deep learning for staging liver fibrosis on CT: a pilot study.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Kunimatsu, Akira; Abe, Osamu; Kiryu, Shigeru

    2018-05-14

    To investigate whether liver fibrosis can be staged by deep learning techniques based on CT images. This clinical retrospective study, approved by our institutional review board, included 496 CT examinations of 286 patients who underwent dynamic contrast-enhanced CT for evaluations of the liver and for whom histopathological information regarding liver fibrosis stage was available. The 396 portal phase images with age and sex data of patients (F0/F1/F2/F3/F4 = 113/36/56/66/125) were used for training a deep convolutional neural network (DCNN); the data for the other 100 (F0/F1/F2/F3/F4 = 29/9/14/16/32) were utilised for testing the trained network, with the histopathological fibrosis stage used as reference. To improve robustness, additional images for training data were generated by rotating or parallel shifting the images, or adding Gaussian noise. Supervised training was used to minimise the difference between the liver fibrosis stage and the fibrosis score obtained from deep learning based on CT images (F DLCT score) output by the model. Testing data were input into the trained DCNNs to evaluate their performance. The F DLCT scores showed a significant correlation with liver fibrosis stage (Spearman's correlation coefficient = 0.48, p deep learning model based on CT images, with moderate performance. • Liver fibrosis can be staged by a deep learning model based on magnified CT images including the liver surface, with moderate performance. • Scores from a trained deep learning model showed moderate correlation with histopathological liver fibrosis staging. • Further improvement are necessary before utilisation in clinical settings.

  14. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  15. Morphometric analysis of three normal facial types in mixed dentition using posteroanterior cephalometric radiographs: preliminary results

    Directory of Open Access Journals (Sweden)

    Renato Bigliazzi

    2017-08-01

    Full Text Available The aim of the present investigation was to evaluate the craniofacial features of subjects with normal occlusion with different vertical patterns in the mixed dentition using morphometric analysis (Thin-Plate Spline analysis - TPS applied to posteroanterior (PA films. The sample comprised 39 individuals (18 females and 21 males, all in mixed dentition, aged from 8.4 to 10 years with satisfactory occlusion and balanced profile and with no history of orthodontic or facial orthopedic treatment. The sample was divided into three groups (mesofacial, brachyfacial and dolichofacial according to the facial types proposed by Ricketts (1989. The average craniofacial configurations of each study group were obtained by orthogonal superimposition of Procrustes, thereby eliminating size differences and allowing only shape differences between groups to be analyzed by viewing the TPS deformation grid. Significant differences were found among the three facial types but were more remarkable between mesofacials and dolichofacials than between mesofacials and brachyfacials. TPS morphometric analysis proved efficient for accurate visualization of transverse and vertical differences among facial types even before pubertal growth spurt. These differences cannot be easily detected by traditional posteroanterior cephalometry.

  16. Direct Determination of Lean Body Mass by CT in F-18 FDG PET/CT Studies: Comparison with Estimates Using Predictive Equations.

    Science.gov (United States)

    Kim, Chang Guhn; Kim, Woo Hyoung; Kim, Myoung Hyoun; Kim, Dae-Weung

    2013-06-01

    The purpose of this study was to estimate lean body mass (LBM) using CT (LBM CTs) and compare the results with LBM estimates of four different predictive equations (LBM PEs) to assess whether LBM CTs and LBM PEs can be used interchangeably for SUV normalization. Whole-body F-18 FDG PET/CT studies were conducted on 392 patients. LBM CT1 is modified adipose tissue-free body mass, and LBM CT2 is adipose tissue-free body mass. Four different PEs were used for comparison (LBM PE1-4). Agreement between the two measurement methods was assessed by Bland-Altman analysis. We calculated the difference between two methods (bias), the percentage of difference, and the limits of agreement, expressed as a percentage. For LBM CTs vs. LBM PEs, except LBM PE3, the ranges of biases and limits of agreement were -3.77 to 3.81 kg and 26.60-35.05 %, respectively, indicating the wide limits of agreement and differing magnitudes of bias. For LBM CTs vs. LBM PE3, LBM PE3 had wider limits of agreement and greater positive bias (44.28-46.19 % and 10.49 to 14.04 kg, respectively), showing unacceptably large discrepancies between LBM CTs and LBM PE3. This study demonstrated that there are substantial discrepancies between individual LBM CTs and LBM PEs, and this should be taken into account when LBM CTs and LBM PEs are used interchangeably between patients.

  17. Data on morphometric analysis of the pancreatic islets from C57BL/6 and BALB/c mice

    Directory of Open Access Journals (Sweden)

    Thiago Aparecido da Silva

    2016-09-01

    Full Text Available The endocrine portion of the pancreas, which is characterized by pancreatic islets, has been widely investigated among different species. The BALB/c and C57BL/6 mice are extensively used in experimental research, and the morphometric differences in the pancreatic islets of these animals have not been evaluated so far. Thus, our data have a comparative perspective related to the morphometric analysis of area, diameters, circularity, and density of pancreatic islets from BALB/c and C57BL/6 mice. The data presented here are focused to evaluate the differences in morphology of pancreatic islets of two common laboratory mouse strains. Keywords: Pancreatic islets, Morphometry, BALB/c and C57BL/6 mice

  18. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    Science.gov (United States)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  19. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    International Nuclear Information System (INIS)

    Osman, N D; Shamsuri, S B M; Razali, M A S M; Isa, S M; Tan, Y W

    2017-01-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDI vol and CTDI w ) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDI w ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients. (paper)

  20. Minamata disease demonstrated by computed tomography

    International Nuclear Information System (INIS)

    Matsumoto, S.C.; Okajima, T.; Inayoshi, S.; Ueno, H.

    1988-01-01

    Computed tomography was studied in the patients with Minamata disease, a methylmercury poisoning caused by the ingestion of contaminated sea foods. The characteristic changes in the acquired cases were atrophy of the visual calcarine cortex and of the cerebellar vermis and or hemisphere. Marked atrophy of the calcarine cortex produced the sac-shaped low density areas between the occipital lobes and diffuse and marked cerebellar atrophy with enlargement of the fourth ventricle and cisterns of the posterior fossa produced a shrunken image on CT. Morphometric analysis confirmed these findings. In the fetal cases, the changes on CT were slight and no definite atrophy was demonstrated in either the calcarine cortex or the cerebellum. Morphometric analysis disclosed an increase of size of the middle portions of the lateral ventricle and the third and fourth ventricles. (orig.)

  1. Estimating population age structure using otolith morphometrics

    DEFF Research Database (Denmark)

    Doering-Arjes, P.; Cardinale, M.; Mosegaard, Henrik

    2008-01-01

    known-age fish individuals. Here we used known-age Atlantic cod (Gadus morhua) from the Faroe Bank and Faroe Plateau stocks. Cod populations usually show quite large variation in growth rates and otolith shape. We showed that including otolith morphometrics into ageing processes has the potential...... populations. The intercalibration method was successful but generalization from one stock to another remains problematic. The development of an otolith growth model is needed for generalization if an operational method for different populations is required in the future....... to make ageing objective, accurate, and fast. Calibration analysis indicated that a known-age sample from the same population and environment is needed to obtain robust calibration; using a sample from a different stock more than doubles the error rate, even in the case of genetically highly related...

  2. Epidemiology Study on P53 (Rs1614984 C>T Mutation in Cigarette Smokers

    Directory of Open Access Journals (Sweden)

    Dilshad Ahmad

    2017-05-01

    Full Text Available ABSTRACT Epidemiology data have established that smoking is a prime threat for the cancers, largely lung cancer. Single-nucleotide polymorphisms (SNPs,P53 SNPs have been found to be associated with the predisposition of different cancers. Their decreased expression is reported in breast and lung cancer patients. p53 (rs1614984 had been reported to be linked with the SNPs found associated with breast cancer. The primary aim of this study to determine the association of p53 variant rs1614984 with the cigarette smokers and smoking related cancers in smokers. Among the smokers, 38% were found with CC genotype, 55% were heterozygous CT and 7% were TT, respectively. The homozygous TT genotype was seen in lower percentage of smokers (7% when compared to non-smokers (8% whereas; Significant difference was not observed when encompassed by CC, CT and TT genotypes (χ2 = 4.892, p=0.087. However, CC vs CT genotype showed a significant difference between smokers and non-smokers (p=0.031, OR 1.447 (1.035-2.025 and the dominant model CC vs CT+TT was also significantly different among smoker and non-smokers (p=0.047, OR 1.39 (1.004-1.924. Furthermore, smokers are at the risk of developing variety of diseases including lung cancer. Our finding suggests a higher percentage of heterozygous CT genotype in smokers when compared to non-smokers. Therefore, this finding gives a clue that the transition mutation of C>T (rs1614984 may leads to the lung diseases including cancer in smokers. However, there will be a need of more extensive and elaborated study to set down the aspect of p53(rs1614984 C>T in lung cancer among smokers.

  3. Morphometric characteristics of sycamore maple (Acer pseudoplatanus L. fruits in Novi Sad urban populations

    Directory of Open Access Journals (Sweden)

    Kostić Saša

    2017-01-01

    Full Text Available This paper shows the results of the analysis of the fruit morphometric characteristics of 29 trees of sycamore maple (Acer pseudoplatanus L. and red - leaf sycamore maple (Acer pseudoplatanus ‘Аtropurpureum’ Späth. in Novi Sad area. Based on the test trees, it can be concluded that the analyzed secondary population of sycamore maple has a high level of intra - populations variability, based on different degrees of variability of measured parameters and statistically significant differences of all analyzed parameters within the analysed genotypes. The results indicate that there are certain differences between fruit of sycamore maple and its red - leaf variety. Given that there is no statistically significant difference between sites and different urban spaces, it can be concluded that stress factors caused by a high degree of urbanity do not affect the morphometric characteristics of fruits in the analyzed test trees. Testing the symmetry of fruits indicates a high level of genetic variability within the analyzed population.

  4. Baseline study of morphometric traits of wild Capsicum annuum growing near two biosphere reserves in the Peninsula of Baja California for future conservation management.

    Science.gov (United States)

    Murillo-Amador, Bernardo; Rueda-Puente, Edgar Omar; Troyo-Diéguez, Enrique; Córdoba-Matson, Miguel Víctor; Hernández-Montiel, Luis Guillermo; Nieto-Garibay, Alejandra

    2015-05-10

    Despite the ecological and socioeconomic importance of wild Capsicum annuum L., few investigations have been carried out to study basic characteristics. The peninsula of Baja California has a unique characteristic that it provides a high degree of isolation for the development of unique highly diverse endemic populations. The objective of this study was to evaluate for the first time the growth type, associated vegetation, morphometric traits in plants, in fruits and mineral content of roots, stems and leaves of three wild populations of Capsicum in Baja California, Mexico, near biosphere reserves. The results showed that the majority of plants of wild Capsicum annuum have a shrub growth type and were associated with communities consisting of 43 species of 20 families the most representative being Fabaceae, Cactaceae and Euphorbiaceae. Significant differences between populations were found in plant height, main stem diameter, beginning of canopy, leaf area, leaf average and maximum width, stems and roots dry weights. Coverage, leaf length and dry weight did not show differences. Potassium, sodium and zinc showed significant differences between populations in their roots, stems and leaves, while magnesium and manganese showed significant differences only in roots and stems, iron in stems and leaves, calcium in roots and leaves and phosphorus did not show differences. Average fruit weight, length, 100 fruits dry weight, 100 fruits pulp dry weight and pulp/seeds ratio showed significant differences between populations, while fruit number, average fruit fresh weight, peduncle length, fruit width, seeds per fruit and seed dry weight, did not show differences. We concluded that this study of traits of wild Capsicum, provides useful information of morphometric variation between wild populations that will be of value for future decision processes involved in the management and preservation of germplasm and genetic resources.

  5. Morphological and morphometric features of nematode-cysts in Gymnotus inaequilabiatus liver in the Brazilian Pantanal.

    Science.gov (United States)

    Galindo, Gizela Melina; Rodrigues, Robson Andrade; Marcondes, Sandriely Fernanda; Soares, Priscilla; Tavares, Luiz Eduardo Roland; Fernandes, Carlos Eurico

    2017-01-01

    The aim of this study was to determine the morphometric measures and morphological aspects of nematode-cysts in Gymnotus inaequilabiatus, and the presence of melanomacrophage centers (MMCs) associated with the periphery of cysts and in the liver parenchyma. Adult specimens, 34 female (123.1 ± 43.9g) and 45 male (135.5 ± 43.4g), from Paraguay River, Corumbá, Brazil, were used. The number of nematode-cysts was determined in 79 livers and 25 of them randomly selected for histopathological analysis and morphometric measures of nematode-cysts (mean diameter, thickness of collagen layer, and cyst-wall layer). The percentage of cysts with MMCs on the periphery and density in the liver parenchyma was estimated. The average number of macroscopic cysts was of 48.7 ± 2.78. Granulomatous reaction was observed surrounding the cysts. Diameter, collagen layer and cyst-wall measurements were 293.0 ± 75.18 (µm), 17.72 ± 6.01 (µm) and 12.21 ± 9.51 (µm), respectively. The number of nematode-cysts was correlated with hepatosomatic index, (r=0.26, Pcyst diameter (r=0.62, Pnematode-cysts number. Morphological characteristics of hepatic tissue and cysts-nematodes measures suggest that G. inaequilabiatus acts as a paratenic host to nematodes in the larval stage.

  6. [Automated morphometric evaluation of the chromatin structure of liver cell nuclei after vagotomy].

    Science.gov (United States)

    Butusova, N N; Zhukotskiĭ, A V; Sherbo, I V; Gribkov, E N; Dubovaia, T K

    1989-05-01

    The morphometric analysis of the interphase chromatine structure of the hepatic cells nuclei was carried out on the automated TV installation for the quantitative analysis of images "IBAS-2" (by the OPTON firm, the FRG) according to 50 optical and geometric parameters during various periods (1.2 and 4 weeks) after the vagotomy operation. It is determined that upper-molecular organisation of chromatine undergoes the biggest changes one week after operation, and changes of granular component are more informative than changes of the nongranular component (with the difference 15-20%). It was also revealed that chromatine components differ in tinctorial properties, which are evidently dependent on physicochemical characteristics of the chromatine under various functional conditions of the cell. As a result of the correlation analysis the group of morphometric indices of chromatine structure was revealed, which are highly correlated with level of transcription activity of chromatine during various terms after denervation. The correlation quotient of these parameters is 0.85-0.97. The summing up: vagus denervation of the liver causes changes in the morphofunctional organisation of the chromatine.

  7. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  8. PFOS, PFNA, and PFOA sub-lethal exposure to embryonic zebrafish have different toxicity profiles in terms of morphometrics, behavior and gene expression.

    Science.gov (United States)

    Jantzen, Carrie E; Annunziato, Kate A; Bugel, Sean M; Cooper, Keith R

    2016-06-01

    Polyfluorinated compounds (PFC) are a class of anthropogenic, persistent and toxic chemicals. PFCs are detected worldwide and consist of fluorinated carbon chains of varying length, terminal groups, and industrial uses. Previous zebrafish studies in the literature as well as our own studies have shown that exposure to these chemicals at a low range of concentrations (0.02-2.0μM; 20-2000ppb) resulted in chemical specific developmental defects and reduced post hatch survival. It was hypothesized that sub-lethal embryonic exposure to perfluorooctanesulfonic acid (PFOS), perfluorononanoic acid (PFNA), or perfluorooctanoic acid (PFOA) would result in different responses with regard to morphometric, behavior, and gene expression in both yolk sac fry and larval zebrafish. Zebrafish were exposed to PFOS, PFOA, and PFNA (0.02, 0.2, 2.0μM) for the first five days post fertilization (dpf) and analyzed for morphometrics (5 dpf, 14 dpf), targeted gene expression (5 dpf, 14 dpf), and locomotive behavior (14 dpf). All three PFCs commonly resulted in a decrease in total body length, increased tfc3a (muscle development) expression and decreased ap1s (protein transport) expression at 5dpf, and hyperactive locomotor activity 14 dpf. All other endpoints measured at both life-stage time points varied between each of the PFCs. PFOS, PFNA, and PFOA exposure resulted in significantly altered responses in terms of morphometric, locomotion, and gene expression endpoints, which could be manifested in field exposed teleosts. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. JMorph: Software for performing rapid morphometric measurements on digital images of fossil assemblages

    Science.gov (United States)

    Lelièvre, Peter G.; Grey, Melissa

    2017-08-01

    Quantitative morphometric analyses of form are widely used in palaeontology, especially for taxonomic and evolutionary research. These analyses can involve several measurements performed on hundreds or even thousands of samples. Performing measurements of size and shape on large assemblages of macro- or microfossil samples is generally infeasible or impossible with traditional instruments such as vernier calipers. Instead, digital image processing software is required to perform measurements via suitable digital images of samples. Many software packages exist for morphometric analyses but there is not much available for the integral stage of data collection, particularly for the measurement of the outlines of samples. Some software exists to automatically detect the outline of a fossil sample from a digital image. However, automatic outline detection methods may perform inadequately when samples have incomplete outlines or images contain poor contrast between the sample and staging background. Hence, a manual digitization approach may be the only option. We are not aware of any software packages that are designed specifically for efficient digital measurement of fossil assemblages with numerous samples, especially for the purposes of manual outline analysis. Throughout several previous studies, we have developed a new software tool, JMorph, that is custom-built for that task. JMorph provides the means to perform many different types of measurements, which we describe in this manuscript. We focus on JMorph's ability to rapidly and accurately digitize the outlines of fossils. JMorph is freely available from the authors.

  10. CT of petrou bone. Utility to cholesteatoma location. Study of 28 cases

    International Nuclear Information System (INIS)

    Ferrer, M.D.; Espinos, M.A.; Molina, A.; Martinez-Rodrigo, J.; Galant, J.

    1993-01-01

    Twenty-eight patients with cholesteatoma were studied preoperatively by means of CT petrous bone to determine the localization and extension of their lesion. All the patients underwent survey and the intraoperative findings were compared with those resulting from CT. The reading was carried out with no knowledge of the intraoperative data. The following results were obtained: localization of cholesteatoma in attic, antrum and posterior tympanic cavity had a sensitivity of 0.91 and a specificity of 0.57, with a Fisher's p value less than 0.0005. When the erosion produced by the cholesteatoma was studied in the different structures, the accuracy was greatest with the stape, the septum and prussak's space; the highest number of false negatives corresponded to the tympanic membrane. The false positives were produced in the assessment of the facial canal, tegmen tympani and the labyrinthine fistula. The reliability of CT was very high for the diagnosis of ossicular destruction and displacement of the small bones, as well as for the state of the mastoid cells and congenital variations. In conclusion, we point out the importance of performing a CT study prior to surgery for cholesteatoma due to its elevated sensitivity in locating the lesion, and we stress the value of the knowledge of the erosion of the different structures since it constitutes a guide for intraoperative exploration and assessment. (Author)

  11. Topological data analysis as a morphometric method: using persistent homology to demarcate a leaf morphospace

    Science.gov (United States)

    Current morphometric methods that comprehensively measure shape cannot compare the disparate leaf shapes found in flowering plants and are sensitive to processing artifacts. Here we describe a persistent homology approach to measuring shape. Persistent homology is a topological method (concerned wit...

  12. Value of surveillance {sup 18}F FDG PET/CT in colorectal cancer:comparison with conventional imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Eun Kyoung; Yoo, Ie Ryung; Park, Hye Lim; Choi, Hyun Su; Han, Eun Ji; Kim, Sung Hoon; Chung, Soo Kyo; O, Joo Hyun [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2012-09-15

    To assess the value of PET/CT for detecting local or distant recurrence in patients who undergo surgery for colorectal cancer (CRC)and to compare the accuracy of PET/CT to that of conventional imaging studies (CIS). Tumor surveillance PET/CT scans done between March 2005 and December 2009 of disease free patients after surgery with or without adjuvant chemotherapy for CRC were retrospectively studied. CIS (serial enhanced CT from lung base to pelvis and plain chest radiograph)were performed within 1 month of PET/CT. We excluded patients with distant metastasis on initial staging, a known recurrent tumor, and a lack of follow up imaging. The final diagnosis was based on at least 6 months of follow up with colonoscopy, biopsy, and serial imaging studies in combination with carcinoembryonic antigen levels. A total of 262 PET/CT scans of 245 patients were included. Local and distant recurrences were detected in 27 cases (10.3%). On case based analysis, the overall sensitivity, specificity, and accuracy were 100, 97.0, and 97.3% for PET/CT and 85.1, 97.0, and 95.8% for CIS, respectively. On lesion based analysis, PET/CT detected more lesions compared to CIS in local recurrence and lung metastasis. PET/CT and CIS detected the same number of lesions in abdominal lymph nodes, hepatic metastasis, and peritoneal carcinomatosis. PET/CT detected two more metachronous tumors than did CIS in the lung and thyroid gland. PET/CT detected more recurrences in patients who underwent surgery for CRC than did CIS and had the additional advantage of evaluating the entire body during a single scan.

  13. A prospective study to evaluate the impact of FDG-PET on CT-based radiotherapy treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Leong, Trevor; Everitt, Craig; Yuen, Kally; Condron, Sara; Hui, Andrew; Ngan, Samuel Y.K.; Pitman, Alexander; Lau, Eddie W.F.; MacManus, Michael; Binns, David; Ackerly, Trevor; Hicks, Rodney J.

    2006-01-01

    Background and purpose: This prospective study sought to determine how the use of combined PET/CT for radiotherapy treatment planning of oesophageal cancer would alter the delineation of tumour volumes compared to CT alone if PET/CT is assumed to more accurately represent true disease extent. Patients and methods: All patients underwent FDG-PET/CT scanning in the radiotherapy treatment position. For each patient, two separate gross tumour volumes (GTV) were defined, one based on CT images alone (GTV-CT) and another based on combined PET/CT data (GTV-PET). Corresponding planning target volumes (PTV) were generated, and separate treatment plans were then produced. For each patient, volumetric analysis of GTV-CT, PTV-CT and GTV-PET was performed to quantify the proportion of PET-avid disease that was not included in the GTV and PTV (geographic miss) if CT data alone were used for radiotherapy planning. Assessment of the cranial and caudal extent of the primary oesophageal tumour as defined by CT alone vs PET/CT was also compared. Results: The addition of PET information altered the clinical stage in 8 of 21 eligible patients enrolled on the study (38%); 4 patients had distant metastatic disease and 4 had unsuspected regional nodal disease. Sixteen patients proceeded to the radiotherapy planning phase of the study and received definitive chemoradiation planned with the PET/CT data set. The GTV based on CT information alone excluded PET-avid disease in 11 patients (69%), and in five patients (31%) this would have resulted in a geographic miss of gross tumour. The discordance between CT and PET/CT was due mainly to differences in defining the longitudinal extent of disease in the oesophagus. The cranial extent of the primary tumour as defined by CT vs PET/CT differed in 75% of cases, while the caudal extent differed in 81%. Conclusions: This study demonstrates that if combined PET/CT is used for radiotherapy treatment planning, there may be alterations to the delineation

  14. Automated quantification of emphysema in CT studies of the lung

    International Nuclear Information System (INIS)

    Archer, D.C.; deKemp, R.A.; Coblentz, C.L.; Nahmias, C.

    1991-01-01

    Emphysema by definition is a pathologic diagnosis. Recently, in vivo quantification of emphysema from CT with point counting and with a GE 9800 CT scanner program called Density Mask has been described. These methods are laborious and time-consuming, making them unsuitable for screening. The propose of this paper is to create a screening test for emphysema. The authors developed a computer program that quantifies the amount of emphysema from standard CT-scans. The computer was programmed to recognize the lung edges on each section by identifying abrupt changes in CT numbers; grow regions within each lung to identify and separate the lungs from other structures; count regions of lung containing CT numbers measuring <-900 HU corresponding to areas of emphysema; and calculation the percentage of emphysema present from the volume of normal emphysematous lung. The programs were written in C and urn on a Sun 4/100 workstation

  15. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  16. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  17. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  18. Differentiation of adrenal adenomas from nonadenomas using CT histogram analysis method: A prospective study

    International Nuclear Information System (INIS)

    Halefoglu, Ahmet Mesrur; Bas, Nagihan; Yasar, Ahmet; Basak, Muzaffer

    2010-01-01

    Objective: The objective of our study was to prospectively evaluate the effectiveness of computed tomography (CT) histogram analysis method in the differentiation of benign and malignant adrenal masses. Materials and Methods: Between March 2007 and June 2008, 94 patients (46 males, 48 females, age range: 30-79 years, mean age: 57.7 years) with 113 adrenal masses (mean diameter: 3.03 cm, range: 1.07-8.02 cm) were prospectively evaluated. These included 66 adenomas, 45 metastases and 2 pheochromocytomas. Histogram analysis method was performed using a circular region of interest (ROI) and mean attenuation, total number of pixels, number of negative pixels and subsequent percentage of negative pixels were detected on both unenhanced and delayed contrast-enhanced CT images for each adrenal mass. A mean attenuation threshold of 10 Hounsfield unit (HU) for unenhanced CT and 5% and 10% negative pixel thresholds for both unenhanced and delayed contrast-enhanced CT were calculated by a consensus of at least two reviewers and the correlation between mean attenuation and percentage of negative pixels was determined. Final diagnoses were based on imaging follow-up of minimum 6 months, biopsy, surgery and adrenal washout study. Results: 51 of 66 adenomas (77.3%) showed attenuation values of ≤10 HU and 15 (22.7%) adenomas showed more than 10 HU on unenhanced CT. All of these adenomas contained negative pixels on unenhanced CT. Eight of 66 (12.1%) adenomas showed a mean attenuation value of ≤10 HU on delayed contrast-enhanced scans and 45 adenomas (68.2%) persisted on containing negative pixels. All metastases had an attenuation value of greater than 10 HU on unenhanced CT images. 21 of 45 (46.6%) metastases contained negative pixels on unenhanced images but only seven metastases (15.5%) had negative pixels on delayed contrast-enhanced images. Two pheochromocytomas had negative pixels on both unenhanced and delayed contrast-enhanced CT images. Increase in the percentage of

  19. Morphometric evaluation of keratocystic odontogenic tumor before and after marsupialization

    Directory of Open Access Journals (Sweden)

    Deborah Campos Telles

    2013-12-01

    Full Text Available The aim of the present study was the morphometric evaluation of the epithelial lining and fibrous capsule in histological specimens of keratocystic odontogenic tumors (KOTs before and after marsupialization. Histological sections from six KOTs that had undergone marsupialization followed by enucleation were photographed. The thickness and features of the capsule and of the epithelial lining of the tumor were evaluated upon marsupialization and upon subsequent enucleation using Axion Vision software. The histological specimens taken upon marsupialization presented an epithelial lining that is typical of KOTs. After marsupialization, the enucleated specimens had a modified epithelial lining and a fibrous capsule that both presented a greater median thickness (p = 0.0277 and p = 0.0212, respectively, morphological changes, and significant enlargement. These modifications can facilitate full surgical treatment and may well be related to a low KOT recurrence rate.

  20. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  1. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  2. Relationship between personality and gray matter volume in healthy young adults: a voxel-based morphometric study.

    Directory of Open Access Journals (Sweden)

    Fengmei Lu

    Full Text Available This study aims to investigate the neurostructural foundations of the human personality in young adults. High-resolution structural T1-weighted MR images of 71 healthy young individuals were processed using voxel-based morphometric (VBM approach. Multiple regression analyses were performed to identify the associations between personality traits and gray matter volume (GMV. The Eysenck Personality Questionnaire-Revised, Short Scale for Chinese was chosen to assess the personality traits. This scale includes four dimensions, namely, extraversion, neuroticism, psychoticism, and lie. Particularly, we studied on two dimensions (extraversion and neuroticism of Eysenck's personality. Our results showed that extraversion was negatively correlated with GMV of the bilateral amygdala, the bilateral parahippocampal gyrus, the right middle temporal gyrus, and the left superior frontal gyrus, all of which are involved in emotional and social cognitive processes. These results might suggest an association between extraversion and affective processing. In addition, a positive correlation was detected between neuroticism and GMV of the right cerebellum, a key brain region for negative affect coordination. Meanwhile, a negative association was revealed between GMV of the left superior frontal gyrus and neuroticism. These results may prove that neuroticism is related to several brain regions involved in regulating negative emotions. Based on those findings, we concluded that brain regions involved in social cognition and affective process accounted for modulation and shaping of personality traits among young individuals. Results of this study may serve as a basis for elucidating the anatomical factors of personality.

  3. Morphometric study of uninvolved rectal mucosa 10 cm and 20 cm away from the malignant tumor.

    Science.gov (United States)

    Despotović, Sanja Z; Milićević, Novica M; Milosević, Dragoslav P; Despotović, Nebojsa; Erceg, Predrag; Bojić, Bozidar; Bojić, Danijela; Svorcan, Petar; Mihajlović, Gordana; Dorđević, Jelena; Lalić, Ivana M; Milićević, Zivana

    2014-02-01

    Recently, many details of the interplay between tumor cells and tumor-associated stromal elements leading to the progression of malignant disease were elucidated. In contrast, little is known about the role of uninvolved stromal tissue in the remote surrounding of the malignant tumor. Therefore, we performed a computer-aided morphometric study of rectal mucosa in samples taken 10 cm and 20 cm away from the malignant tumor during endoscopic examination of 23 patients older than 60 years. The samples of rectal mucosa from 10 healthy persons of corresponding age subjected to diagnostic rectoscopy during active screening for asymptomatic cancer were used as control. All structural elements of the rectal mucosa were studied and the number of nucleated cells in the lamina propria per 0.1 mm² of tissue was assessed. Our study revealed a reduced number of cells in the lamina propria of the rectal mucosa 10 cm and 20 cm away from the tumor lesion in both male and female patients. The decreased mucosal height and increased crypt number were registered in female patients 10 cm away from the tumor. The connective tissue of lamina propria showed a disorderly organization: the collagen fibers were frail, loosely arranged and signs of tissue edema were present. Small blood vessels and capillaries were much more frequently seen than in healthy tissue. Our results demonstrate the complex interactions between the cancer and remote mucosal tissue of the affected organ.

  4. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  5. The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

    Science.gov (United States)

    Vorona, G A; Zuccoli, G; Sutcavage, T; Clayton, B L; Ceschin, R C; Panigrahy, A

    2013-01-01

    Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.

  6. A study of effective sequences on micro-CT in the dent-maxillo-facial region

    International Nuclear Information System (INIS)

    Kato, Masataka; Mori, Shintaro; Sakayanagi, Masashi; Fujita, Yuzo; Kaneda, Takashi

    2005-01-01

    Microfocus computed tomography (micro-CT) using cone-beam scan is becoming widely used for various studies of oral structures. However, this machine has not been used to evaluate the effective parameters for two-dimensional (2D) or three-dimensional (3D) images. This study evaluated the effective parameters of micro-CT for 2D or 3D images of oral hard tissue structures. We evaluated the CT value of 5 human teeth (upper first molars) to determine suitable CT value examined according to several X-ray parameters using conformal radiotherapy (CRT) on a work station. CT information from the specimens was obtained using a micro-CT (Toscaner-31300 μ, Toshiba ITC), under the conditions of tube voltage of 75 kV, tube current of 120 μA, 100∼1600 views, the number of times of addition, 512 x 512 pixel matrix, and 0.2 slice thickness. We made 3D-reconstruction images from the micro-CT data. Three-dimensional reconstruction was performed using 2D images processed by the volume-rendering method using 3D-reconstruction software (TRI/3D BON, RATOC system engineering). Then, we evaluate the 3D tooth images. In the assessment of images, three dental radiologists evaluated several 3D tooth images using 3D-reconstruction images. Each image was scored on a five-level scale by Scheffe one-pair comparison method as follows: 5: much easier to evaluate, 4: easier to evaluate, 3: equivalent, 2: harder to evaluate, 1: much harder to evaluate. In scoring, each of the three dental radiologists made an individual assessment, and when differences among individual scores occurred, the score was ultimately assigned by consensus among the three individuals. Statistical analysis of the scores assigned by the three dental radiologists as described above was carried out using Stat View-J 5.0 (Abacus Concepts, Inc, USA) statistical software and Tukey-Kramer multiple-comparison testing. The optimal CT value for evaluating the human tooth by micro-CT is 600 on 2D images. On 3D images, the optimal

  7. Value of CT scanning in radiation therapy treatment planning: a prospective study

    International Nuclear Information System (INIS)

    Goitein, M.; Wittenberg, J.; Mendiondo, M.; Doucette, J.; Friedberg, C.; Ferrucci, J.; Gunderson, L.; Linggood, R.; Shipley, W.U.; Fineberg, H.V.

    1979-01-01

    We report the results of a prospective study in which we assessed the value of computed tomography (CT) scanning in planning radiation therapy for 77 patients. First, conventional studies were performed, treatment fields were designed and simulated and, where appropriate, computer generated treatment plans drawn up. Then a CT scan was performed to delineate the location of the tumor and adjacent uninvolved tissues. The treatment goals and plans were reevaluated and changed when necessary. Forty of the 77 patients (52%) had their treatment changed as a result of the CT scan. Of these, four (5%) had a change of treatment modality. Thirty-two patients (42%) had changes in the radiotherapy technique because of inadequate tumor coverage (in 24 patients (31%) part of the tumor was outside one or more of the fields and in the other 8 patients (10%) the tumor coverage was marginal). Field changes resulting only from considerations of normal tissue coverage were made for 4 of these patients (5%). In total, normal tissue coverage was affected in 36 patients (47%). When the significance of these changes was evaluated, CT scanning was judged to be of major value for 28 of the 77 patients (36%) and of minor value in a further 12 patients

  8. CT study of infantile cerebral vitamin B1 deficiency (analysis of 22 cases)

    International Nuclear Information System (INIS)

    Liu Bin; Xi Meifang; Wang Mengding; Wang Chaoxiu

    1998-01-01

    Purpose: To study the CT features of infantile cerebral vitamin B 1 deficiency. Methods: The authors retrospectively reviewed the clinical manifestations and CT findings of 22 cases of infantile vitamin B 1 deficiency. Results: The main clinical signs were seizure malaise dullness and vomiting. CT scans showed bilateral symmetrical hypodense foci in lenticular nucleus (20/22), head of caudate nucleus (15/22), thalamus (3/22), anterior limb of internal capsule (4/22), external capsule (1/22) and para-ventricle white matter (2/22), and in many cases, signs of cerebral atrophy. 22 cases received thiamine treatment and were fully recovered. Conclusion: The authors concluded that bilateral symmetric hypodense foci in lenticular nucleus thalamus, head of caudate nucleus, anterior limb of internal capsule, external capsule and para-ventricle white matter were important CT signs suggestive of infantile cerebral vitamin B 1 deficiency

  9. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  10. Strategy study of quantification harmonization of SUV in PET/CT images

    International Nuclear Information System (INIS)

    Fischer, Andreia Caroline Fischer da Silveira

    2014-01-01

    In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative

  11. Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage.

    Science.gov (United States)

    Chen, Xiaoyan; Saravelos, Sotirios H; Liu, Yingyu; Huang, Jin; Wang, Chi Chiu; Li, Tin Chiu

    2017-06-01

    Power Doppler in combination with three-dimensional (3D-PD) ultrasonography has been used as a noninvasive tool to evaluate the vascularity. However, it is unclear whether 3D-PD can accurately reflect endometrial vascularization and replace the invasive endometrial biopsy. This study aims to investigate the correlation between 3D-PD and micro vessel morphometric measurement of endometrial vascularity. Twenty-five women with unexplained recurrent miscarriage were recruited for 3D-PD and endometrial biopsy on precisely day LH + 7. Immunohistochemistry using vWF was employed to identify micro vessels in endometrial biopsy specimens followed by the use of morphometric technique to measure the mean vessel diameter and volume fractions. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) assessed by 3D-PD were calculated for both the endometrial and sub-endometrial regions. There were no significant correlations between any of the ultrasonographic measurements (endometrial thickness, endometrial volume, endometrial VI/FI/VFI, sub-endometrial volume, sub-endometrial VI/FI/VFI) and morphometric features (number of micro vessel, mean diameter of micro vessel and volume fraction measurement of vessel). This study indicates that endometrial vascularity assessed by 3D-PD could not be used to reflect changes in micro vessels of the endometrium at the time of embryo implantation in women with unexplained recurrent miscarriage.

  12. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  13. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  14. CT study of pancreatic diseases with modified dynamic scanning

    International Nuclear Information System (INIS)

    Qian Minghui; Zhu Guangying

    1990-01-01

    Experience of 20 cases modified dynamic CT scanning is presented. With a slight increased X-ray tube burden, it is possible to investigate tumor blood supply and find small pancreatic insulinoma with this method. The capsular sign typical for chronic traumatic pancreatic hematoma on CT is presented

  15. Geometric and morphometric analysis of fish scales to identity genera, species and populations case study: the Cyprinid family

    Directory of Open Access Journals (Sweden)

    Seyedeh Narjes Tabatabei

    2014-01-01

    Full Text Available Using fish scale to identity species and population is a rapid, safe and low cost method. Hence, this study was carried out to investigate the possibility of using geometric and morphometric methods in fish scales for rapid identification of species and populations and compare the efficiency of applying few and/or high number of landmark points. For this purpose, scales of one population of Luciobarbus capito, four populations of Alburnoides eichwaldii and two populations of Rutilus frisii kutum, all belonging to cyprinid family, were examined. On two-dimensional images of the scales 7 and 23 landmark points were digitized in two separate times using TpsDig2, respectively. Landmark data after generalized procrustes analysis were analyzed using Principal Component Analysis (PCA, Canonical Variate Analysis (CVA and Cluster Analysis. The results of both methods (using 7 and 23 landmark points showed significant differences of the shape of scales among the three species studied (P0.05. The results also showed that few number of landmarks could display the differences between scale shapes. According to the results of this study, it could be stated that the scale of each species had unique shape patterns which could be utilized as a species identification key.

  16. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  17. MORPHOMETRIC PARAMETERS AND MICRORELIEF OF THE LUMBRICUS CELOMOCYTES IN THE CONDITIONS OF THE OSMOTIC PRESSURE

    Directory of Open Access Journals (Sweden)

    Andrey Andreevich Prisnyi

    2017-10-01

    Full Text Available Background: Study the morphometric parameters and microrelief of the coelomocytes membrane of the Lumbricus representatives in normal and under osmotic pressure. Materials and methods: In the experiments, representatives of three species belonging to the genus Lumbricus were used. To conduct each series of experiments a coelomic liquid of 15 representatives of each species was used. From the circulation system of each individual examined, at least 250 cells were processed. The study of morphometric parameters of coelomocytes was carried out in isotonic conditions, and also with the use of osmotic tests in vitro. The features of the surface topography of coelomocytes were study using the “Integra Vita Probe Nanaboratorium” (NT-MDT, Russia. The analysis of amplitude and functional average statistical parameters of membrane roughness is carried out. The results of the research were processed using statistics methods using the Microsoft Excel 7.0 analysis package. Results: The Lumbricus representatives of revealed differences in the responses of amoebocytes and eleocytes to the effect of osmotic stress. Under the conditions of osmotic pressure, several morphologically different forms were found among the cells of each type. This indicates the potential ability of coelomocytes to spread out on the substrate for any type of osmotic pressure. The change in the topography of the cell membrane of coelomocytes under the hypoosmotic pressure is characterized by a smoothing of the microrelief structures with a decrease in the size of the microvysings and microinvaginations. Conclusion: The microrelief of the coelomocytes membrane reflects the features of their functional status changing under the influence of environmental factors.

  18. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  19. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  20. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data