WorldWideScience

Sample records for morphometric ct study

  1. A morphometric CT study of Down's syndrome showing small posterior fossa and calcification of basal ganglia

    International Nuclear Information System (INIS)

    Ieshima, A.; Yoshino, K.; Takashima, S.; Takeshita, K.; Kisa, T.

    1984-01-01

    We report characteristic and morphometric changes of cranial computed tomography (CT) with increasing age in 56 patients with Down's syndrome aged from 0 month to 37 years. Patients were compared with 142 normal controls aged 0 to 59 years. Width of ventricles, Sylvian fissures, posterior fossa, pons and cisterna magna were measured on CT. The incidences of the cavum septi pellucidi, cavum vergae and cavum veli interpositi and high density in the basal ganglia were examined. There was high incidence (10.7%) of bilateral calcification of basal ganglia in Down's syndrome, although that of pineal body and choroid plexus calcification was similar in Down's syndrome and controls. Basal ganglia calcification is more frequently seen in young Down's syndrome and may be related to the premature aging characteristic of Down's syndrome. The CT in Down's syndrome showed relatively small posterior fossa, small cerebellum, small brain stem and relatively large Sylvian fissures in those under one year of age. There was a high frequency of midline cava and large cisterna magna. There were no significant atrophic changes on CT except after the fifth decade comparing with controls. (orig.)

  2. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  3. Morphometric anatomical and CT study of the human adult sacroiliac region.

    Science.gov (United States)

    Postacchini, Roberto; Trasimeni, Guido; Ripani, Francesca; Sessa, Pasquale; Perotti, Stefano; Postacchini, Franco

    2017-01-01

    To identify and describe the morphometry and CT features of the articular and extra-articular portions of the sacroiliac region. The resulting knowledge might help to avoid complications in sacroiliac joint (SIJ) fusion. We analyzed 102 dry hemi-sacra, 80 ilia, and 10 intact pelves and assessed the pelvic computerized tomography (CT) scans of 90 patients, who underwent the examination for conditions not involving the pelvis. We assessed both the posterior aspect of sacrum with regard to the depressions located externally to the lateral sacral crest at the level of the proximal three sacral vertebrae and the posteroinferior aspect of ilium. Coronal and axial CT scans of the SIJ of patients were obtained and the joint space was measured. On each side, the sacrum exhibits three bone depressions, not described in anatomic textbooks or studies, facing the medial aspect of the posteroinferior ilium, not yet described in detail. Both structures are extra-articular portions situated posteriorly to the SIJ. Coronal CT scans of patients showing the first three sacral foramens and the interval between sacrum and ilium as a continuous space display only the S1 and S3 portions of SIJ, the intermediate portion being extra-articular. The S2 portion is visible on the most anterior coronal scan. Axial scans show articular and extra-articular portions and features improperly described as anatomic variations. Extra-articular portions of the sacroiliac region, not yet described exhaustively, have often been confused with SIJ. Coronal CT scans through the middle part of sacrum, the most used to evaluate degenerative and inflammatory conditions of SIJ, show articular and extra-articular portions of the region.

  4. Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2010-09-01

    The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r

  5. Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

    Science.gov (United States)

    Qian, Li-Xiong; Hao, Ding-Jun; He, Bao-Rong; Jiang, Yong-Hong

    2013-05-01

    To quantify the dimensions of the atlas pedicles and to analyze the relationship between extra medullary height (EMH) with intra medullary height (IMH) of the atlas pedicle. The images of the patients who had CT scanning and three-dimensional (3D) reconstruction involving atlantoaxial complex between June 2011 and April 2012 and meet our inclusion criteria were studied retrospectively. After reformatting the original images, the EMH and IMH of the atlas pedicles were measured. Extra medullary height and IMH were, respectively, 4.83 ± 1.13 and 1.29 ± 1.10 mm for males and 3.75 ± 0.93 and 0.60 ± 0.83 mm for females, with statistical difference (P atlas pedicles were measured by using CT images of the atlas, providing anatomic parameters for surgery. They showed a certain correlation but with a high variability. C1 pedicle screw fixation was well performed when the medullary canal was ≥1 mm, but the surgical procedure should be careful when it was between 0 and 1 mm, and avoided when there was no medullary canal in the atlas pedicle! So 3D CT reconstruction should be conducted to obtain data and establish individualized fixation strategy preoperatively.

  6. Morphometric studies on the facial skeleton of humans and pongids based on CT-scans.

    Science.gov (United States)

    Schumacher, K U; Koppe, T; Fanghänel, J; Schumacher, G H; Nagai, H

    1994-10-01

    The changes of the skull, which we can observe during the anthropogenesis, are reflected especially in the different skull proportions. We carried out metric measurements at the median level on 10 adult skulls each of humans, chimpanzees and gorillas as well as 11 skulls of orangutans. All skulls were scanned with a CT at the median level. We measured the lines and angles of the scans and the means and the standard deviations were calculated. We carried out a correlation analysis to observe the relation of their characteristics. We showed that there is a relation between the length of the skull base and the facial length in all species. From the results of the correlation analysis, we can also conclude that a relation exists between the degree of prognathism and the different length measurements of the facial skeleton. We also found a bending of the facial skeleton in relation to the cranial base towards the ventral side, also known as klinorhynchy, in all observed species. The highest degree of klinorhynchy was found in humans and the lowest in orangutans. We will discuss the different definition of the term klinorhynchy and its importance in the evolution of the hominoids.

  7. Morphometric study of Euchiton (Gnaphalieae: Asteraceae)

    NARCIS (Netherlands)

    Flann, C.M.

    2010-01-01

    A morphometric study was undertaken to survey taxa in the genus Euchiton Cass., distributed across Australia, New Zealand and South-east Asia. Phenetic analyses of herbarium specimens showed several taxa to be well delimited, including E. brassii (Mattf.) Anderb., E. breviscapus (Mattf.) Anderb., E.

  8. STUDY OF MORPHOMETRIC CHANGES OF FOETAL STOMACH

    Directory of Open Access Journals (Sweden)

    Mohammed Aneesur Rahman

    2017-07-01

    Full Text Available BACKGROUND Interest in human development is very widespread largely because of the curiosity about our beginnings and desire to improve the quality of life. Understanding of the processes involved in the formation of various organs and systems has unrevealed most cryptic secrets of the nature. Human development begins at fertilisation when a male gamete or sperm unites with a female gamete or oocyte to form a single cell, a zygote. With the formation of zygote (single-celled stage, foetal development begins. The aim of the study is to- 1 Study the morphometric parameters of foetal stomach at various gestational ages. 2 Compare these observations with the previous studies. MATERIALS AND METHODS Present work was the cross-sectional study carried out in the Department of Anatomy in collaboration with the Department of Obstetrics and Gynaecology at SRTRGMC and Hospital, Ambajogai Dist., Beed, Maharashtra. For this, approval of Institutional Ethical Committee was taken. 30 aborted human foetuses of different age groups ranging from 12 to 36 weeks of fertilisation were taken from the Department of OB-GYN. Foetuses were preserved by using 10% formalin. Age of foetuses were determined by crown-rump length and history given by mother. Foetuses were dissected after preservation for 15 days and morphometric studies were done on stomach. RESULTS Various quantitative parameters like weight of foetus, crown-rump length, total length of stomach, weight of stomach, length of greater curvature, lesser curvature, width of cardia and width of pylorus were used. For the purpose of study and comparison with other researchers, the foetuses were divided into 3 groups. Morphometric changes were observed in different groups and compared with previous studies. CONCLUSION With the increase in the body weight, crown-rump length and gestational age of the foetus, there is gradual increase on various parameters of stomach.

  9. Experimental sharp force injuries to ribs: Multimodal morphological and geometric morphometric analyses using micro-CT, macro photography and SEM.

    Science.gov (United States)

    Komo, Larissa; Grassberger, Martin

    2018-07-01

    Tool marks on bones induced by knife blades can be analysed morphometrically in order to enable an allocation of the suspected "inflicting weapon" to the particular morphology of the bone lesions. Until now, geometric morphometrics has not been used to analyse the morphology of knife lesions on fleshed bones in detail. By using twelve experimental knives and a drop weight tower, stab/cut injuries were inflicted on untreated pig ribs. The morphology of the experimentally produced lesions was subsequently recorded with three imaging techniques (μCT, macro photography and SEM) and analysed with different morphometric software (Amira, tps and Morpheus). Based on the measured distances between the walls of the kerf marks, which corresponded to the thickness of the blade, one could conclude to the respective blade thickness with a deviation of max. ±0.35mm and match the injuries to the knives. With subsequent reanalysis after maceration, an average shrinkage factor up to 8.6% was observed. Among the three imaging techniques used in this study, μCT was the most accurate and efficient technique, particularly because it represented the only non-destructive modality to document injuries without maceration, even though μCT is more expensive and time-consuming as well as less accessible than a macro SLR-camera or a SEM. For optimal characterizations of the blades' and kerfs' shapes the software tps proofed to be the best choice. Accordingly, geometric morphometrics could serve as a tool in forensic investigations concerning kerf marks. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Automation process for morphometric analysis of volumetric CT data from pulmonary vasculature in rats.

    Science.gov (United States)

    Shingrani, Rahul; Krenz, Gary; Molthen, Robert

    2010-01-01

    With advances in medical imaging scanners, it has become commonplace to generate large multidimensional datasets. These datasets require tools for a rapid, thorough analysis. To address this need, we have developed an automated algorithm for morphometric analysis incorporating A Visualization Workshop computational and image processing libraries for three-dimensional segmentation, vascular tree generation and structural hierarchical ordering with a two-stage numeric optimization procedure for estimating vessel diameters. We combine this new technique with our mathematical models of pulmonary vascular morphology to quantify structural and functional attributes of lung arterial trees. Our physiological studies require repeated measurements of vascular structure to determine differences in vessel biomechanical properties between animal models of pulmonary disease. Automation provides many advantages including significantly improved speed and minimized operator interaction and biasing. The results are validated by comparison with previously published rat pulmonary arterial micro-CT data analysis techniques, in which vessels were manually mapped and measured using intense operator intervention. Published by Elsevier Ireland Ltd.

  11. Longitudinal morphometric MRI study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Ogomori, Koji; Takano, Koichi; Kuwabara, Yasuo; Nakano, Seigo; Nawata, Hideyuki; Yano, Rika; Nishimura, Ryoji; Takita, Masashi

    2009-01-01

    A longitudinal morphometric MRI study of Alzheimer's disease (AD) was conducted to determine the relationship between the progression of the symptoms and the progression of the brain atrophy. The Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD), developed by Matsuda et al. was used as a method of morphometry to perform the statistical MR image analysis. Thirty-eight patients of AD patients were investigated with VSRAD. These patients were divided into two groups according to the progression of symptoms based on a clinical evaluation. One group was the progress group (20 patients), while the other group was the stable group (18 patients) for comparison. The relationship was investigated between the speed of the symptomatic progression and the change in each VSRAD indicator. Consequently, the entorhinal Z-score and the entorhinal atrophy rate showed a correlation with the speed of the symptomatic progression. The increase of the entorhinal Z-score in the follow-up was larger in the progress group than that in the stable group (0.65/1.28 years in the progress group and 0.05/1.26 years in the stable group.). These results suggest that a rapid symptomatic progression in an AD patient accompanies the rapid progression of atrophy in the entorhinal cortex. (author)

  12. A MORPHOMETRIC STUDY OF THE SELLA TURCICA; GENDER EFFECT

    OpenAIRE

    Ashraf Mohamed Elsayed Ali SAKRAN *1, Mohammad Afzal KHAN 2, Faris Mohammed Nour ALTAF 3, Hassan Elsiddig Hassan FARAGALLA 4, Amal Yousif Ahmed Elhaj MUSTAFA 5, Muhammad Mazhar HIJAZI 6, Rayan Abdulshakur NIYAZI 7, Abrar Jamal TAWAKUL 8, Abeer Zubair MALEBARI 9, Amal AbdulAziz SALEM 10.

    2015-01-01

    Background and objective: Precise anatomical knowledge of the sella turcica is important for neurologists and surgeons operating in the region of cavernous sinus or the surrounding structures. The current study was undertaken to record normal morphometric parameters for future reference and to determine if there is any significance difference in the sella turcica morphometry regarding the gender. Methodology: A Morphometric analysis of the Sella Turcica and structures in vicinity were done...

  13. The use of maxillary sinus dimensions in gender determination: a thin-slice multidetector computed tomography assisted morphometric study.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Inci, Ercan; Hocaoglu, Elif; Sayin, Ibrahim; Kayhan, Fatma Tulin; Can, Ismail Ozgur

    2014-05-01

    Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. In the present study, morphometric analysis of maxillary sinuses was performed to determine gender. For morphometric analysis, coronal and axial paranasal sinus computed tomography (CT) scan with 1-mm slice thickness was used. For this study, 140 subjects (70 women and 70 men) were enrolled (age ranged between 18 and 63). The size of each subject's maxillary sinuses was measured in anteroposterior, transverse, cephalocaudal, and volume directions. In each measurement, the size of the maxillary sinus is significantly small in female gender (P discrimination analysis was performed, the accuracy rate was detected as 80% for women and 74.3% for men with an overall rate of 77.15%. With the use of 1-mm slice thickness CT, morphometric analysis of maxillary sinuses will be helpful for gender determination.

  14. Morphometric Studies Of The Cerebellum And Forebrain Of The ...

    African Journals Online (AJOL)

    Morphometric studies were undertaken using the brains of six African giant rats. The mean of weights and lengths (tip of the olfactory bulb to the caudal border of the cerebellum) were observed tobe 4.88 0.183g and 4.40 0.193g, respectively. Similarly, the mean weight and length of the cerebellum and the forebrain ...

  15. Morphometric studies on a part of Central Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Kodagali, V.N.

    Morphometric and slope angle studies carried out on a part of Indian Ocean Basin have shown that gentle slope angle ranges dominate, 92% of the area represented by 0-3 degrees slopes. Young's hypothesis of log-normal distribution of slope angle...

  16. External morphometric study of hatchery reared mahseer ( Tor ...

    African Journals Online (AJOL)

    Different samples of Mahseer (Tor putitora) were examined for the study of external morphometric characters of the fish. Slopes of log transformed data were used for comparison with an isometric slopes (b=1, b= 0.33 or b= 3). Relationships between wet body weight and external body parts lengths showed that increasing ...

  17. CT-based morphometric analysis of the occipital condyle: focus on occipital condyle screw insertion.

    Science.gov (United States)

    Zhou, Jinsong; Espinoza Orías, Alejandro A; Kang, Xia; He, Jade; Zhang, Zhihai; Inoue, Nozomu; An, Howard S

    2016-11-01

    OBJECTIVE The segmental occipital condyle screw (OCS) is an alternative fixation technique in occipitocervical fusion. A thorough morphological study of the occipital condyle (OC) is critical for OCS placement. The authors set out to introduce a more precise CT-based method for morphometric analysis of the OC as it pertains to the placement of the segmental OCS, and they describe a novel preoperative simulation method for screw placement. Two new clinically relevant parameters, the height available for the OCS and the warning depth, are proposed. METHODS CT data sets from 27 fresh-frozen human cadaveric occipitocervical spines were used. All measurements were performed using a commercially available 3D reconstruction software package. The length, width, and sagittal angle of the condyle were measured in the axial plane at the base of the OC. The height of the OC and the height available for the segmental OCS were measured in the reconstructed oblique sagittal plane, fitting the ideal trajectory of the OCS recommended in the literature. The placement of a 3.5-mm-diameter screw that had the longest length of bicortical purchase was simulated into the OC in the oblique sagittal plane, with the screw path not being blocked by the occiput and not violating the hypoglossal canal cranially or the atlantooccipital joint caudally. The length of the simulated screw was recorded. The warning depth was measured as the shortest distance from the entry point of the screw to the posterior border of the hypoglossal canal. RESULTS The mean length and width of the OC were found to be larger in males: 22.2 ± 1.7 mm and 12.1 ± 1.0 mm, respectively, overall (p < 0.0001 for both). The mean sagittal angle was 28.0° ± 4.9°. The height available for the OCS was significantly less than the height of the OC (6.2 ± 1.3 mm vs 9.4 ± 1.5 mm, p < 0.0001). The mean screw length (19.3 ± 1.9 mm) also presented significant sex-related differences: male greater than female (p = 0.0002). The

  18. Climatic effects on the nasal complex: a CT imaging, comparative anatomical, and morphometric investigation of Macaca mulatta and Macaca fascicularis.

    Science.gov (United States)

    Márquez, Samuel; Laitman, Jeffrey T

    2008-11-01

    Previous studies exploring the effects of climate on the nasal region have largely focused on external craniofacial linear parameters, using dry crania of modern human populations. This investigation augments traditional craniofacial morphometrics with internal linear and volumetric measures of the anatomic units comprising the nasal complex (i.e., internal nasal cavity depth, maxillary sinus volumes). The study focuses on macaques (i.e., Macaca mulatta and Macaca fascicularis) living at high and low altitudes, rather than on humans, since the short residency of migratory human populations may preclude using them as reliable models to test the long-term relationship of climate to nasal morphology. It is hypothesized that there will be significant differences in nasal complex morphology among macaques inhabiting different climates. This study integrated three different approaches: CT imaging, comparative anatomy, and morphometrics-in an effort to better understand the morphological structure and adaptive nature of the nasal complex. Results showed statistically significant differences when subsets of splanchnocranial and neurocranial variables were regressed against total maxillary sinus volume for particular taxa. For example, basion-hormion was significant for M. fascicularis, whereas choanal dimensions were significant only for M. mulatta. Both taxa revealed strong correlation between sinus volume and prosthion to staphylion distance, which essentially represents the length of the nasal cavity floor-and is by extension an indicator of the air conditioning capacity of the nasal region. These results clearly show that climatic effects play a major role in shaping the anatomy of the nasal complex in closely related species. The major influence upon these differing structures appears to be related to respiratory-related adaptations subserving differing climatic factors. In addition, the interdependence of the paranasal sinuses with other parts of the complex strongly

  19. Morphometric studies on Culex quinquefasciatus and Mansonia ...

    African Journals Online (AJOL)

    are difficult to identify based solely on examination of adult females using the available morphological keys. In this study, adult mosquitoes were collected ... ures) it is necessary to identify the species of adult females which are found near ... M. africana is known to transmit Rift Valley fever. (Meegan & Bailey, 1988; Fontenille ...

  20. A MORPHOMETRIC STUDY OF THE VARIEGATED GRASSHOPPER

    African Journals Online (AJOL)

    BIG TIMMY

    Department of Zoology, Obafemi Awolowo University, Ile-Ife, Nigeria. Correspondence a. Morphometry of the dry-season population of adult ... female specimens from Port-Harcourt were the most correctly classified compared to specimens from other locations . The present study demonstrated the morphological similarities ...

  1. Morphometric study of the avian adrenal gland.

    Science.gov (United States)

    Aire, T A

    1980-01-01

    The interrenal and medullary cords as well as the blood vessels and connective tissue proportions in the adrenal glands of the male Nigerian fowl (Gallus domesticus) and guinea-fowl (Numida meleagris) were studied by microstereological techniques. Laying domestic fowl of the Rhode Island Red breed were entirely defeathered and maintained in a hot, humid pen for a period of three months, after which the adrenal glands were also studied microstereologically. Interrenal cord width was also measured in all the birds studied. The interrenal cords of the subscapular zone were consistently wider than those cords in the inner zone of the adrenal glands. This clearly suggested morphological zoning. The proportion of interrenal tissue was significantly greater in the guinea-fowl than in the Nigerian fowl, but the medullary tissue and the blood vessels and connective tissue were not significantly different. Interrenal hypoplasia or medullary hyperplasia occurred in the defeathered Rhode Island Red fowl as compared to the control birds of the same breed and sex. The significance of these findings is discussed. PMID:7440402

  2. Morphometric Study of the Anterior Thalamoperforating Arteries

    Science.gov (United States)

    Kim, Sung-Ho; Yeo, Dong-Kyu; Shim, Jae-Joon; Yoon, Seok-Mann; Chang, Jae-Chil

    2015-01-01

    Objective To evaluate the morphometry of the anterior thalamoperforating arteries (ATPA). Methods A microanatomical study was performed in 79 specimens from 42 formalin-fixed adult cadaver brains. The origins of the ATPAs were divided into anterior, middle, and posterior segments according to the crowding pattern. The morphometry of the ATPAs, including the premammillary artery (PMA), were examined under a surgical microscope. Results The anterior and middle segments of the ATPAs arose at mean intervals of 1.75±1.62 mm and 5.86±2.05 mm from the internal carotid artery (ICA), and the interval between these segments was a mean of 3.17±1.64 mm. The posterior segment arose at a mean interval of 2.43±1.46 mm from the posterior cerebral artery (PCA), and the interval between the middle and posterior segments was a mean of 3.45±1.39 mm. The mean numbers of perforators were 2.66±1.19, 3.03±1.84, and 1.67±0.98 in the anterior, middle, and posterior segments, respectively. The PMA originated from the middle segment in 66% of cases. A perforator-free zone was located >2 mm from the ICA in 30.4% and >2 mm from the PCA in 67.1% of cases. Conclusion Most perforators arose from the anterior and middle segments, within the anterior two-thirds of the posterior communicating artery (PCoA). The safest perforator-free zone was located closest to the PCA. These anatomical findings may be helpful to verify safety when treating lesions around the PCoA and in the interpeduncular fossa. PMID:26113962

  3. Micro-computed tomography (μCT) as a novel method in ecotoxicology — determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    Energy Technology Data Exchange (ETDEWEB)

    Brinkmann, Markus, E-mail: markus.brinkmann@bio5.rwth-aachen.de [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Rizzo, Larissa Y.; Lammers, Twan; Gremse, Felix [Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen (Germany); Schiwy, Sabrina [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Kiessling, Fabian [Department of Experimental Molecular Imaging, Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Aachen (Germany); Hollert, Henner, E-mail: henner.hollert@bio5.rwth-aachen.de [Department of Ecosystem Analysis, Institute for Environmental Research, RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); College of Resources and Environmental Science, Chongqing University, 1 Tiansheng Road Beibei, Chongqing 400715 (China); College of Environmental Science and Engineering, State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, 1239 Siping Road, Shanghai (China); State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University (China)

    2016-02-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. - Highlights: • μCT was used for volumetric imaging sediment-exposed and unexposed rainbow trout • Liver volumes determined by μCT were highly correlated with liver weights. • The perfusion of organs in fish could also be studied by means of μCT. • It was shown that μCT is a useful tool in context of ecotoxicological research.

  4. Micro-computed tomography (μCT) as a novel method in ecotoxicology — determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    International Nuclear Information System (INIS)

    Brinkmann, Markus; Rizzo, Larissa Y.; Lammers, Twan; Gremse, Felix; Schiwy, Sabrina; Kiessling, Fabian; Hollert, Henner

    2016-01-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. - Highlights: • μCT was used for volumetric imaging sediment-exposed and unexposed rainbow trout • Liver volumes determined by μCT were highly correlated with liver weights. • The perfusion of organs in fish could also be studied by means of μCT. • It was shown that μCT is a useful tool in context of ecotoxicological research.

  5. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    International Nuclear Information System (INIS)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da; Alves, Jose Marcos

    2014-01-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  6. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da, E-mail: alhakme@sc.usp.br [Universidade de Sao Paulo (EESC/FMRP/IQSC/USP), Sao Carlos, SP (Brazil); Alves, Jose Marcos [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Departamento de Engenharia Eletrica e Computacao

    2014-07-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  7. 3D osteocyte lacunar morphometric properties and distributions in human femoral cortical bone using synchrotron radiation micro-CT images.

    Science.gov (United States)

    Dong, Pei; Haupert, Sylvain; Hesse, Bernhard; Langer, Max; Gouttenoire, Pierre-Jean; Bousson, Valérie; Peyrin, Françoise

    2014-03-01

    Osteocytes, the most numerous bone cells, are thought to be actively involved in the bone modeling and remodeling processes. The morphology of osteocyte is hypothesized to adapt according to the physiological mechanical loading. Three-dimensional micro-CT has recently been used to study osteocyte lacunae. In this work, we proposed a computationally efficient and validated automated image analysis method to quantify the 3D shape descriptors of osteocyte lacunae and their distribution in human femurs. Thirteen samples were imaged using Synchrotron Radiation (SR) micro-CT at ID19 of the ESRF with 1.4μm isotropic voxel resolution. With a field of view of about 2.9×2.9×1.4mm(3), the 3D images include several tens of thousands of osteocyte lacunae. We designed an automated quantification method to segment and extract 3D cell descriptors from osteocyte lacunae. An image moment-based approach was used to calculate the volume, length, width, height and anisotropy of each osteocyte lacuna. We employed a fast algorithm to further efficiently calculate the surface area, the Euler number and the structure model index (SMI) of each lacuna. We also introduced the 3D lacunar density map to directly visualize the lacunar density variation over a large field of view. We reported the lacunar morphometric properties and distributions as well as cortical bone histomorphometric indices on the 13 bone samples. The mean volume and surface were found to be 409.5±149.7μm(3) and 336.2±94.5μm(2). The average dimensions were of 18.9±4.9μm in length, 9.2±2.1μm in width and 4.8±1.1μm in depth. We found lacunar number density and six osteocyte lacunar descriptors, three axis lengths, two anisotropy ratios and SMI, that are significantly correlated to bone porosity at a same local region. The proposed method allowed an automatic and efficient direct 3D analysis of a large population of bone cells and is expected to provide reliable biological information for better understanding the

  8. Micro-computed tomography (μCT) as a novel method in ecotoxicology--determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss).

    Science.gov (United States)

    Brinkmann, Markus; Rizzo, Larissa Y; Lammers, Twan; Gremse, Felix; Schiwy, Sabrina; Kiessling, Fabian; Hollert, Henner

    2016-02-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's condition index) and somatic indices (e.g. hepatosomatic, and gonadosomatic index). Standard measurements of somatic indices are invasive and require, by definition, the sacrifice of examined animals, thus prohibiting longitudinal studies and relocation of animals captured in the field. As a potential solution, in the present study, we propose the use of micro-computed tomography (μCT) as imaging modality to non-invasively tomographically image rainbow trout (Oncorhynchus mykiss) exposed to different sediment suspensions. We here demonstrate that μCT can be used as a tool to reliably measure the volumes of different organs, which could then be applied as a substitute of their weights in calculation of somatic indices. To the best of our knowledge, this study is the first to report the results of μCT analyses in the context of ecotoxicological research in rainbow trout. It has the potential to greatly increase the information value of experiments conducted with fish and also to potentially reduce the number of animals required for studying temporal effects through facilitating longitudinal studies within the same individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Outline-based morphometrics, an overlooked method in arthropod studies?

    Science.gov (United States)

    Dujardin, Jean-Pierre; Kaba, D; Solano, P; Dupraz, M; McCoy, K D; Jaramillo-O, N

    2014-12-01

    Modern methods allow a geometric representation of forms, separating size and shape. In entomology, as well as in many other fields involving arthropod studies, shape variation has proved useful for species identification and population characterization. In medical entomology, it has been applied to very specific questions such as population structure, reinfestation of insecticide-treated areas and cryptic species recognition. For shape comparisons, great importance is given to the quality of landmarks in terms of comparability. Two conceptually and statistically separate approaches are: (i) landmark-based morphometrics, based on the relative position of a few anatomical "true" or "traditional" landmarks, and (ii) outline-based morphometrics, which captures the contour of forms through a sequence of close "pseudo-landmarks". Most of the studies on insects of medical, veterinary or economic importance make use of the landmark approach. The present survey makes a case for the outline method, here based on elliptic Fourier analysis. The collection of pseudo-landmarks may require the manual digitization of many points and, for this reason, might appear less attractive. It, however, has the ability to compare homologous organs or structures having no landmarks at all. This strength offers the possibility to study a wider range of anatomical structures and thus, a larger range of arthropods. We present a few examples highlighting its interest for separating close or cryptic species, or characterizing conspecific geographic populations, in a series of different vector organisms. In this simple application, i.e. the recognition of close or cryptic forms, the outline approach provided similar scores as those obtained by the landmark-based approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Magnetic resonance imaging in schizophrenia: a morphometric study

    International Nuclear Information System (INIS)

    Castro, Claudio Campi de

    2001-01-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  11. Postmortem acinar autolysis in rat sublingual gland: a morphometric study.

    Science.gov (United States)

    Nery, Leticia Rodrigues; Moreira, Carla Ruffeil; Cestari, Tania Mary; Taga, Rumio; Damante, José Humberto

    2010-01-01

    To analyze and to quantify morphological acinar postmortem changes in rat sublingual glands (SLG). MATERIAL AND METHODSs: Fifty rats were divided into two groups of 25 animals each. Group I was used for morphological and morphometric evaluations and group II for the determination of gland density and processed gland volume. Acinar autolytic changes were studied at 0 (control group), 3, 6, 12 and 24 h postmortem periods. The morphometric analysis of the volume density (Vv) and total volume (Vt) of intact (ia) and autolyzed (aa) acini was performed under light microscopy using a Zeiss II integration grid with 100 symmetrically distributed points. Morphologically, temporal progressive nuclear alterations and gradual loss of the structural architecture of acinar cells were found. Regarding quantitative results, both the Vvaa and the Vvia showed statistically significant differences among all postmortem periods (p0.05), respectively. Vtaa increased from 0.18 mm³ at 0 h to 38.17 mm³ at 12 h, while Vtia showed a decrease from 33.47 mm³ to 0 mm³ between 3-24 h postmortem. Data concerning Vtaa were adjusted by two-variable linear regression, obtaining the equation: y=-3.54+3.38x (r²=0.90). The Vtaa growth rate calculated by this equation was 3.38 mm³/h between 0-12 h. Acinar autolysis on rat SLG demonstrated the most significant signs during the first 6 h postmortem and was widely spread through the gland at 12 h.

  12. Morphometric Study of Vocal Folds in Indian Cadavers

    Directory of Open Access Journals (Sweden)

    Rawal J.D.

    2015-06-01

    Full Text Available Introduction: -The larynx is an air passage and a sphincteric device used in respiration and phonation. The larynx, from inside outwards has a framework of mucosa surrounded by fibro-elastic membrane which in turn is surrounded by cartilages and then a layer of muscles. Vocal folds are intrinsic ligament of larynx covered by mucosal folds. Larynx generates sound through rhythmic opening and closing of the vocal folds. The perceived pitch of human voice mainly depends upon fundamental frequency of sound generated by larynx. Aim: - The aim of present study is to measure various dimensions of vocal folds in Indian cadavers. Material & Methods: - 50 larynx were obtained from embalmed cadavers, of which 10 larynx were of females. Vocal cords were dissected from the larynx and morphometric analysis was done. Results and Conclusions: - The average total length of the vocal folds was found to be 16.11 mm. ± 2.62 mm. in male and 14.10 mm. ± 1.54 mm. in female cadavers. The average width of the vocal folds was found to be 4.38 mm. ± 0.74 mm. in male and 3.60 mm. ± 0.64 mm. in female cadavers. The average total length of the membranous part of the vocal folds was found to be 11.90 mm. ± 1.86 mm. in male and 10.45 mm. ± 1.81 mm. in female cadavers. The average ratio of the length of the membranous and the cartilaginous parts of the vocal folds was calculated to be 3.10 ± 0.96in male and 2.85 ± 0.73in female cadavers.

  13. Morphometric analysis of the infraorbital foramen, canal and groove using cone beam CT: considerations for creating artificial organs.

    Science.gov (United States)

    Orhan, Kaan; Misirli, Melis; Aksoy, Secil; Seki, Umut; Hincal, Evren; Ormeci, Tugrul; Arslan, Ahmet

    2016-01-01

    The aim of this study was to examine the anatomy and variations of the infraorbital foramen and its surroundings via morphometric measurements using cone beam computed tomography (CBCT) scans derived from a 3D volumetric rendering program. 354 sides of CBCT scans from 177 patients were examined in this study. DICOM data from these images were exported to Maxilim® software in order to generate 3D surface models. The morphometric measurements were done for infraorbital foramen (IOF), infraorbital groove (IOG) and infraorbital canal (IOC). All images were evaluated by 1 radiologist. To assess intra-observer reliability, the Wilcoxon matched-pairs signed rank test was used. Differences between sex, side, age and measurements were evaluated using chi-square and paired t-test and measurements were evaluated using 1-way ANOVA tests. Differences were considered significant when p0.05). No significant difference was found according to age groups (p>0.05). These results provide detailed knowledge of the anatomical characteristics in this particular area. CBCT imaging with lower radiation dose and thin slices can be a powerful tool for anesthesia procedures like infra orbital nerve blocks, for surgical approaches like osteotomies and neurectomies and also for generating artificial prostheses.

  14. MORPHOMETRIC STUDY OF MEDIAL COLLATERAL LIGAMENTS OF ANKLE

    Directory of Open Access Journals (Sweden)

    Neelu Prasad

    2016-06-01

    is very poorly understood. The ligament in case of tear or injury has to be repaired which is impossible to do so if a proper morphometric knowledge is not known. So a sincere effort has been put in the study to find the morphometry of the deltoid ligament. METHODS  One hundred specimens were dissected. In this, fifty belonged to the right and fifty belonged to the left side.  The study was done in the Department of Anatomy, Nalanda Medical College, Patna.  The study was done from June 2015 to April 2016.  The morphometry was seen and the comparisons were done.  The dissection was done to expose the deltoid ligament. The anterior, middle and posterior length was taken. Then, the superior, middle and inferior width was taken. Then, the thickness was measured.  Then, the presence or absence of the deep part was noted. RESULTS Irrespective of the side and sex to which the ligaments belong, the mean value of the length of the deltoid ligaments in the anterior, middle and posterior parts are 24.40 mm, 21.53 mm and 17.20 mm. The widths in the superior, middle and inferior parts are 19.94 mm, 22.59 mm and 27.45 mm. The thickness mean measurement is 6.94 mm. Deep Part was found in 100% of cases. The superficial part trapezoid in shape wide anteriorly and narrow posteriorly, also is narrow superiorly where it arises and broad inferiorly where it gets inserted. CONCLUSION The ligaments of the talocrural joint are one of the most difficult ligaments to study. A sincere effort has been put in this study to find the morphometry of ligaments of ankle joint. The same has been studied and reported successfully to help the surgeons to understand and help the needful in a better way.

  15. Sex determination from the frontal bone: a geometric morphometric study.

    Science.gov (United States)

    Perlaza, Néstor A

    2014-09-01

    Sex estimation in human skeletal remains when using the cranium through traditional methods is a fundamental pillar in human identification; however, it may be possible to incur in a margin of error due because of the state of preservation in incomplete or fragmented remains. The aim of this investigation was sex estimation through the geometric morphometric analysis of the frontal bone. The sample employed 60 lateral radiographs of adult subjects of both sexes (30 males and 30 females), aged between 18 and 40 years, with mean age for males of 28 ± 4 and 30 ± 6 years for females. Thin-plate splines evidenced strong expansion of the glabellar region in males and contraction in females. No significant differences were found between sexes with respect to size. The findings suggest differences in shape and size in the glabellar region, besides reaffirming the use of geometric morphometrics as a quantitative method in sex estimation. © 2014 American Academy of Forensic Sciences.

  16. Novel Automated Morphometric and Kinematic Handwriting Assessment: A Validity Study in Children with ASD and ADHD

    Science.gov (United States)

    Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.

    2017-01-01

    This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…

  17. Changes in mast cells during acute radiation sickness(a morphometric study)

    International Nuclear Information System (INIS)

    Datsenko, A.V.; Shikhodyrov, V.V.

    1985-01-01

    Changes in the morphometric parameters of rat mast cells during acute radiation sickness have been studied. The most significant deviation of the quantitative indices of mast cells from the control values were noted at the height of the bone-marrow, at the terminal stage of the intestinal, and during the first few hours of the cerebral forms of acute radiation sickness

  18. Morphometric and Histological Study of Osteophytes in Human Cadaveric Lumbar Vertebrae

    OpenAIRE

    Ashwini Aithal Padur; Naveen Kumar; Swamy Ravindra Shanthakumar; Arijit Bishnu

    2017-01-01

    Introduction: Osteophytes are bony outgrowth on the vertebral column. Its prevalence in the lumbar region and clinical importance mandates to conduct a detailed study of lumbar osteophytes in the cadaveric vertebral column. Aim: The present study was conducted to study the detailed features of lumbar osteophytes and document its prevalence, morphometric and histological structure. Materials and Methods: This was an observational study in which frequency of occurrence of lumbar osteophyt...

  19. A Morphometric Study of Auricular Concha in the Population of Young Chinese Adults

    OpenAIRE

    Zhu, Zhaohua; Ji, Xiaomin; Gao, Zhu; Hu, Gang

    2017-01-01

    SUMMARY: A detailed data of concha is currently not available. Therefore, the present study aimed to determine twelve morphometric measurements of concha, to investigate its sexual dimorphism and bilateral asymmetry, and to establish basic shapes of concha for both sexes and sides. The study sample comprised of 310 young Chinese aged 18-28 years. 141 left and 141 right ear impressions for females, 169 left and 169 right ear impressions for males were collected and scanned. The 3D coordinates ...

  20. Population studies of Glossina pallidipes in Ethiopia: emphasis on cuticular hydrocarbons and wing morphometric analysis.

    Science.gov (United States)

    Getahun, M N; Cecchi, G; Seyoum, E

    2014-10-01

    Tsetse flies, like many insects, use pheromones for inter- and intra-specific communication. Several of their pheromones are cuticular hydrocarbons (CHCs) that are perceived by contact at close range. We hypothesized that for a successful implementation of the Sterile Insect Technique (SIT), along with proper identification of target area and target species, the target tsetse populations and the sterile flies must chemically communicate with each other. To study the population structuring of Glossina pallidipes in Ethiopia, CHCs were extracted and analyzed from three tsetse belts. As a comparative approach, wing morphometric analysis was performed. The analysis of the relative abundance of CHCs revealed that populations of G. pallidipes from the Rift Valley tsetse belt showed a distinct clustering compared to populations from the other two belts. The spatial pattern of CHC differences was complemented by the wing morphometric analysis. Our data suggest that CHCs of known biological and ecological role, when combined with wing morphometric data, will provide an alternative means for the study of population structuring of Glossina populations. This could aid the planning of area wide control strategies using SIT, which is dependent on sexual competence. Copyright © 2014 International Atomic Energy Agency 2014. Published by Elsevier B.V. All rights reserved.

  1. Morphometric and rheological study of lunar domes of Marius Hills ...

    Indian Academy of Sciences (India)

    70

    (2013) had given emphasis to the study of the morphology of cones having diameters between 1 to2 km using .... for the dome-35 is marked with a white polygon as shown in Fig.5a. Orthoimage, ..... Geochemical and mineralogical analysis of ...

  2. Gross morphometric study on the reproductive system of Japanese ...

    African Journals Online (AJOL)

    Quail farming is emerging in commercial poultry farming to provide alternatives to domestic chicken production and also strengthen the poultry production demands for animal protein. This study was conducted to determine the gross morphometry of the ovary and oviduct of inapparently healthy adult laying Japanese quail ...

  3. Studies on the life cycle and morphometrics of honeybees, Apis ...

    African Journals Online (AJOL)

    The life cycle of the honeybee, Apis mellifera adansonii, was studied in mangrove area by monitoring the developmental stages and morphology of the castes. It was observed that the fate of the eggs were predetermined at the onset leading to drones, queens or workers. It was also established that the three different castes ...

  4. Anatomy of the Human Subthalamic Nucleus: A Combined Morphometric Study

    Directory of Open Access Journals (Sweden)

    Ioannis Mavridis

    2013-01-01

    Full Text Available Purpose. Our purpose was to provide a combined clinically oriented study focused on the detailed anatomy of the human STN, with great respect to its targeting. Methods. For our imaging study, we used cerebral magnetic resonance images (MRIs from 26 neurosurgical patients and for our anatomic study 32 cerebral hemispheres from 18 normal brains from cadaver donors. We measured and analyzed the STN dimensions (based on its stereotactic coordinates. Results. At stereotactic level Z=-4, the STN length was 7.7 mm on MRIs and 8.1 mm in anatomic specimens. Its width was 6 mm on MRIs and 6.3 mm in anatomic specimens. The STN was averagely visible in 3.2 transverse MRI slices and its maximum dimension was 8.5 mm. The intercommissural distance was 26.3 mm on MRIs and 27.3 mm in anatomic specimens. We found statistically significant difference of the STN width and length between individuals <60 and ≥60 years old. Conclusion. The identification of the STN limits was easier in anatomic specimens than on MRIs and easier on T2 compared to T1-weighted MRIs sections. STN dimensions appear slightly smaller on MRIs. Younger people have wider and longer STN.

  5. A voxel-based MRI morphometric study of Alzheimer's disease

    International Nuclear Information System (INIS)

    Hao Jing; Li Kuncheng; Yang Yanhui; Wang Wei; Li Ke; Yan Bin; Shan Baoci

    2005-01-01

    Objective: To assess the diagnostic value of voxel-based Morphometry (VBM) in studying Alzheimer's disease (AD). Methods: Graymatter density were comprehensive assessed by means of VBM on T 1 -weighted MRI volume sets in 19 patients with AD and 15 healthy subjects of similar age and gender ratio, 15 healthy adults. The data were collected on Siemens 1.5 T Sonata MRI systems and analyzed by SPM 99 to generate gray matter density map. Results: Relative to healthy controls, significant clusters of reduced gray matter density were found to affect medial temporal lobe ( hippocampus) (P<0.001). For hippocampus, reduced gray matter density were 1529 in the right and 1281 in the left with right-sided predominance. Moreover, atrophy of right caudate head and left medial thalamus were showed. We demonstrate global asymmetrical cortical atrophy with sparing of the sensorimotor cortex, occipital lobe and cerebellum. Conclusion: The results from VBM are in perfect agreement with those of earlier neuroimaging, which confirmed its value in demonstrating neuroanatomy of AD. VBM, the simple and automatic approach providing a full-brain assessment of AD morphology, has a good clinical perspective. (authors)

  6. Increased Insular Cortical Thickness Associated With Symptom Severity in Male Youths With Internet Gaming Disorder: A Surface-Based Morphometric Study

    Science.gov (United States)

    Wang, Shuai; Liu, Jing; Tian, Lin; Chen, Limin; Wang, Jun; Tang, Qunfeng; Zhang, Fuquan; Zhou, Zhenhe

    2018-01-01

    With the rising increase in Internet-usage, Internet gaming disorder (IGD) has gained massive attention worldwide. However, detailed cerebral morphological changes remain unclear in youths with IGD. In the current study, our aim was to investigate cortical morphology and further explore the relationship between the cortical morphology and symptom severity in male youths with IGD. Forty-eight male youths with IGD and 32 age- and education-matched normal controls received magnetic resonance imaging scans. We employed a recently proposed surface-based morphometric approach for the measurement of cortical thickness (CT). We found that youths with IGD showed increased CT in the bilateral insulae and the right inferior temporal gyrus. Moreover, significantly decreased CT were found in several brain areas in youths with IGD, including the bilateral banks of the superior temporal sulci, the right inferior parietal cortex, the right precuneus, the right precentral gyrus, and the left middle temporal gyrus. Additionally, youths with IGD demonstrated a significantly positive correlation between the left insular CT and symptom severity. Our data provide evidence for the finding of abnormal CT in distributed cerebral areas and support the notion that altered structural abnormalities observed in substance addiction are also manifested in IGD. Such information extends current knowledge about IGD-related brain reorganization and could help future efforts in identifying the role of insula in the disorder. PMID:29666588

  7. Increased Insular Cortical Thickness Associated With Symptom Severity in Male Youths With Internet Gaming Disorder: A Surface-Based Morphometric Study

    Directory of Open Access Journals (Sweden)

    Shuai Wang

    2018-04-01

    Full Text Available With the rising increase in Internet-usage, Internet gaming disorder (IGD has gained massive attention worldwide. However, detailed cerebral morphological changes remain unclear in youths with IGD. In the current study, our aim was to investigate cortical morphology and further explore the relationship between the cortical morphology and symptom severity in male youths with IGD. Forty-eight male youths with IGD and 32 age- and education-matched normal controls received magnetic resonance imaging scans. We employed a recently proposed surface-based morphometric approach for the measurement of cortical thickness (CT. We found that youths with IGD showed increased CT in the bilateral insulae and the right inferior temporal gyrus. Moreover, significantly decreased CT were found in several brain areas in youths with IGD, including the bilateral banks of the superior temporal sulci, the right inferior parietal cortex, the right precuneus, the right precentral gyrus, and the left middle temporal gyrus. Additionally, youths with IGD demonstrated a significantly positive correlation between the left insular CT and symptom severity. Our data provide evidence for the finding of abnormal CT in distributed cerebral areas and support the notion that altered structural abnormalities observed in substance addiction are also manifested in IGD. Such information extends current knowledge about IGD-related brain reorganization and could help future efforts in identifying the role of insula in the disorder.

  8. Sexual dimorphism of the human corpus callosum: Digital morphometric study

    Directory of Open Access Journals (Sweden)

    Spasojević Goran

    2006-01-01

    Full Text Available Background/Aim. Changes in the morphology and the size of the corpus callosum, are related to various pathological conditions. An analysis of these changes requires data about sexual dimorphism of the corpus callosum, which we tried to obtain in our study. We also investigated the method of digital morphometry and compared the obtained results with the results of other authors obtained by magnetic resonance imaging or by planimetry. Methods. A morphological research included 34 human brains (cadavers of both sexes − 19 female and 15 male aged 26−72 years. By digital morphometry using an AutoCAD software we performed measurements in the corpus callosum: the length (L, width in the half of its length (WW’, length of its cortical margin (LCM, area and perimeter of the anterior and posterior callosal segments, as well as the area and perimeter of the corpus callosum section area. The investigated parameters were analyzed and compared between the females and males. Results. There was not a statistically significant difference between the males and females in the investigated parameters of the corpus callosum (t test; p > 0.05, including the mean values of the two most important parameters, the surface of its midsagittal section area (males 654.11 mm2; females 677.40 mm2 and of its perimeter (males 19.61 cm; females 19.72 cm. The results obtained by digital morphometry were in the range of the results of other authors obtained by magnetic resonance and by planimetry. However, the value of Pearson coefficient of linear correlation between the section surface area and perimeter of the corpus callosum in the males was highly significant (rxy = 0.6943, p < 0.01, while in the females this value was statistically insignificant. Conclusion. Digital morphometry is accurate method in encephalometric investigations. Our results suggest that the problem of sexual dimorphism of the corpus callosum is very complex, because the identical variables (section

  9. Morphometric Study on Male Specimens of Hyalomma Anatolicum (Acari: Ixodidae in West of Iran

    Directory of Open Access Journals (Sweden)

    M Abdigoudarzi

    2011-12-01

    Full Text Available Background: Hyalomma anatolicum is the well-known hard tick, which is one of the most important livestock and hu­man pathogens vector, wide range in host and distributed in all over the Hyalomma geographic fauna as well as in Iran. Taxonomy of the Hyalomma ssp. is debatable whereas their identification is a problematic work. The reasons for this claim is time consuming Delpy’s researches in Iran also Schulze School, Feldman-Muhsam and the Russian tick workers. We would like to understand morphometric variation in the field collected H. anatolicum in Iran also validat­ing some morphologic quantitative and qualitative characters.Methods: A total 247 field-collected tick specimens from different geographical regions in west of Iran includes Khuzestan and Lorestan Provinces were studied. The morphologic characters of the ticks were measured by the cali­brated stereomicroscope ‎armed scaled lens. The measurements were analyzed using SPSS ‎for windows, version 16 on an IBM PC, ‎so varied shapes of species in different geographic ‎regions were drawn by the ‎aid of a drawing tube con­nected to a light stereomicroscope.‎Results: One way ANOVA test revealed significant differences among the quantitative parameters in five zones (P<‎‎ 0.‎‎00‎‎1‎ also each zone to other zone by Post Hoc Tests e.g. LSD. No significant differences in the lateral grooves length/conscutum length ratio parameter were found.Conclusion: Morphometric variation in Hyalomma spp is poorly studied. The variation in range and quantity of the mor­phometric parameters of H.anatolicum ‎underlies that the correct recognition and key construction for Hyalomma spe­cies dependes ‎on a complement morphometric study on the other species.

  10. Morphometric and Histological Study of Osteophytes in Human Cadaveric Lumbar Vertebrae

    Directory of Open Access Journals (Sweden)

    Ashwini Aithal Padur

    2017-10-01

    Full Text Available Introduction: Osteophytes are bony outgrowth on the vertebral column. Its prevalence in the lumbar region and clinical importance mandates to conduct a detailed study of lumbar osteophytes in the cadaveric vertebral column. Aim: The present study was conducted to study the detailed features of lumbar osteophytes and document its prevalence, morphometric and histological structure. Materials and Methods: This was an observational study in which frequency of occurrence of lumbar osteophytes was studied in 40 cadaveric vertebral columns over a period of four years. The lumbar part of the vertebral columns was dissected and examined meticulously. The occurrence of lumbar osteophytes with their vertebral levels and morphometric measurements were recorded. A small excision of the osteophyte was processed histologically to study its microscopic details using routine Haematoxylin & Eosin stain. Results: Lumbar osteophytes were present in 4 specimens (10%. They were mostly found on the right side of the vertebral bodies. Histopathological examination of the osteophytes revealed degenerative osteophytic cartilage and fibrillation overlying the trabecular bone enclosing fatty marrow spaces containing haematopoietic elements. Conclusion: Lumbar osteophytes were found in 10% of the specimens studied and it is assumed that these cadaveric reports deserve further attention given their potential clinical implications. Knowledge regarding occurrence and incidence of osteophytes is essential for management of common degenerative changes of the vertebral column.

  11. Geometric morphometrics as a tool for improving the comparative study of behavioural postures.

    Science.gov (United States)

    Fureix, Carole; Hausberger, Martine; Seneque, Emilie; Morisset, Stéphane; Baylac, Michel; Cornette, Raphaël; Biquand, Véronique; Deleporte, Pierre

    2011-07-01

    Describing postures has always been a central concern when studying behaviour. However, attempts to compare postures objectively at phylogenetical, populational, inter- or intra-individual levels generally either rely upon a few key elements or remain highly subjective. Here, we propose a novel approach, based on well-established geometric morphometrics, to describe and to analyse postures globally (i.e. considering the animal's body posture in its entirety rather than focusing only on a few salient elements, such as head or tail position). Geometric morphometrics is concerned with describing and comparing variation and changes in the form (size and shape) of organisms using the coordinates of a series of homologous landmarks (i.e. positioned in relation to skeletal or muscular cues that are the same for different species for every variety of form and function and that have derived from a common ancestor, i.e. they have a common evolutionary ancestry, e.g. neck, wings, flipper/hand). We applied this approach to horses, using global postures (1) to characterise behaviours that correspond to different arousal levels, (2) to test potential impact of environmental changes on postures. Our application of geometric morphometrics to horse postures showed that this method can be used to characterise behavioural categories, to evaluate the impact of environmental factors (here human actions) and to compare individuals and groups. Beyond its application to horses, this promising approach could be applied to all questions involving the analysis of postures (evolution of displays, expression of emotions, stress and welfare, behavioural repertoires…) and could lead to a whole new line of research.

  12. A computed tomography morphometric study of occipital bone and C2 pedicle anatomy for occipital-cervical fusion.

    Science.gov (United States)

    King, Nicolas K K; Rajendra, Tiruchelvarayan; Ng, Ivan; Ng, Wai Hoe

    2014-01-01

    Occipital-cervical fusion (OCF) has been used to treat instability of the occipito-cervical junction and to provide biomechanical stability after decompressive surgery. The specific areas that require detailed morphologic knowledge to prevent technical failures are the thickness of the occipital bone and diameter of the C2 pedicle, as the occipital midline bone and the C2 pedicle have structurally the strongest bone to provide the biomechanical purchase for cranio-cervical instrumentation. The aim of this study was to perform a quantitative morphometric analysis using computed tomography (CT) to determine the variability of the occipital bone thickness and C2 pedicle thickness to optimize screw placement for OCF in a South East Asian population. Thirty patients undergoing cranio-cervical junction instrumentation during the period 2008-2010 were included. The thickness of the occipital bone and the length and diameter of the C2 pedicle were measured based on CT. The thickest point on the occipital bone was in the midline with a maximum thickness below the external occipital protuberance of 16.2 mm (±3.0 mm), which was thicker than in the Western population. The average C2 pedicle diameter was 5.3 mm (±2.0 mm). This was smaller than Western population pedicle diameters. The average length of the both pedicles to the midpoint of the C2 vertebral body was 23.5 mm (±3.3 mm on the left and ±2.3 mm on the right). The results of this first study in the South East Asian population should help guide and improve the safety in occipito-cervical region instrumentation. Thus reducing the risk of technical failures and neuro-vascular injury.

  13. MORPHOMETRIC ANALYSIS OF CORPUS CALLOSUM- A STUDY IN CADAVER AND MRI

    Directory of Open Access Journals (Sweden)

    Ambili Puthanveetil

    2017-07-01

    Full Text Available BACKGROUND The Corpus Callosum (CC can best be seen in the mid-sagittal section of brain both in cadaver and MRI. The morphometric measurements of the same will be of use in neurosurgical procedures. Sexual dimorphism and the age-related changes in its measurements remained controversial. Till date, no studies have been done on corpus callosum in Kerala. MATERIALS AND METHODS Measurements of CC has been taken and studied in detail in 24 formalin fixed brains from the Department of Anatomy and 48 MR images from the Department of Radiology. The changes according to age and sex were analysed. RESULTS The mean length of CC in the cadaver was 7.24 cm, which was 3.38 cm posterior to frontal pole and 5.73 cm anterior to occipital pole. In MR images, the mean length was 7.10 in males and 6.76 in females. The difference we got was not statistically significant. The length increased with age. Thickness of genu and body decreased as the age advances, but the splenial thickness was found to be increasing with age. There was significant correlation between the thicknesses of various parts of CC. CONCLUSION The values were almost similar to those in the previous studies. Morphometrically, a significant gender difference was not identified in the present study. There were changes according to age both in males and females.

  14. Immunohistochemical and morphometric study of the development of fetal and newborn rat pancreatic islets

    International Nuclear Information System (INIS)

    Badawoud, Mohammed H.

    2003-01-01

    Aim of this study is to perform a detailed morphometric immunohistochemichal study of develpment of fetal and newborn rat pancreatic islets. 24 pancreas were obtained from 19 and 21-day-old fetal rats,1 and 4-day-old newborn rats. They were fixed in a buffered neutral formalin ,dehydrated and embedded in paraplast. Sections were stained with anti-insulin antibodies. Study was performed at Department of Anatomy, King Abdul-Aziz University, Jeddah,Kingdom of Saudi Arabia, between 2001 and 2002. The volume density of B cells showed a grdual increase during the last days of gestation and a slight increase during the first 4 days after birth. All the other morphometric parameters showed a gradual increase during the last days of gestation and during the first days after birth.The B cell nuclear diameter and volume showed a slight increase after birth. B cells were stained and present in the central part of of fetal and new born islets,while the other islet cells were present in the periphery of the islets. The size of endocrine tissue, which was represented by the islet diameter, islet volume, islet volume density, total number of islet cells,number of B cells and volume density of B cells showed a progressive increase during the prenatal period. (author)

  15. CT study in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji [Tokyo Metropolitan Matsuzawa Hospital (Japan)

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, II and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefore, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease.

  16. CT study in Alzheimer's disease

    International Nuclear Information System (INIS)

    Arai, Heii; Kobayashi, Kazunari; Ikeda, Kenji; Nagao, Yoshiko; Ogihara, Ryuji; Kosaka, Kenji

    1983-01-01

    Cerebral atrophy on CT was studied in 18 patients with clinically diagnosed Alzheimer's disease and in 14 healthy age-matched subjects as the control. The patients with Alzheimer's disease were divided into three groups of Stages I, Ii and III, according to their clinical symptoms. The study of the measurement method disclosed that the computerized measurement involving calculation of the number of pixels contained within the range of the designated CT numbers is liable to produce errors for the determination of the subarachnoid spaces and the ventricles with calcified colloid plexus. Therefor, for the present study was the method adopted, in which the subarachnoid spaces and the ventricles are measured based on the number of pixels contained in the region of interest by tracing them on the display monitor. Then, both Subarachnoid Space Volume Index (SVI) and Ventricle Volume Index (VVI) were calculated as the indices for cortical atrophy and ventricular dilatation in a slice through the level of the foramen interventriculare Monroi and other three successive ones through upper regions. Cerebral atrophy observed on CT in Alzheimer patients is attributable to Alzheimer's disease processes, rather than to physiological aging of the brain. The degree of the atrophy increases in proportion to the clinical stage, and cortical atrophy is apparent even at Stage I, whereas ventricular dilatation becomes pronounced at later stage. CT is one of effective clinical tests for the diagnosis of Alzheimer's disease. (J.P.N.)

  17. A geometric morphometric study into the sexual dimorphism of the human scapula.

    Science.gov (United States)

    Scholtz, Y; Steyn, M; Pretorius, E

    2010-08-01

    Sex determination is vital when attempting to establish identity from skeletal remains. Two approaches to sex determination exists: morphological and metrical. The aim of this paper was to use geometric morphometrics to study the shape of the scapula and its sexual dimorphism. The sample comprised 45 adult black male and 45 adult black female scapulae of known sex. The scapulae were photographed and 21 homologous landmarks were plotted to use for geometric morphometric analysis with the 'tps' series of programs, as well as the IMP package. Consensus thin-plate splines and vector plots for males and females were compared. The CVA and TwoGroup analyses indicated that significant differences exist between males and females. The lateral and medial borders of females are straighter while the supraspinous fossa is more convexly curved than that of males. More than 91% of the females and 95% of the males were correctly assigned. Hotelling's T(2)-test yielded a significant p-value of 0.00039. In addition, 100 equidistant landmarks representing the curve only were also assigned. These, however, yielded considerably poorer results. It is concluded that it is better to use homologous landmarks rather than curve data only, as it is most probable that the shape of the outline relative to the fixed homologous points on the scapula is sexually dimorphic.

  18. Morphometric analysis in basaltic Terrain of Central India using GIS techniques: a case study

    Science.gov (United States)

    Sahu, Nisha; Obi Reddy, G. P.; Kumar, Nirmal; Nagaraju, M. S. S.; Srivastava, Rajeev; Singh, S. K.

    2017-09-01

    Morphometric analysis is significant for investigation and management of the watershed. This study depicts the morphometric analysis of Miniwada Watershed in Nagpur district, Maharashtra, Central India using Geographic Information System (GIS) techniques, which has been carried out through measurement of various aspects like linear, aerial and relief aspects of watershed. The drainage network of the watershed was generated from Cartosat-I DEM (10 m) using ESRI Software ArcGIS (ver.10.2). The analysis reveals that drainage pattern is dendritic and the stream order in the watershed varies from 1 to 4. The total number of stream segments of all orders counted as 37, out of which the majority of orders (70.27 %) was covered by 1st order streams and 4th order stream segments covers only 2.70 %. The bifurcation ratio reflects the geological and tectonic characteristics of the watershed and estimated as 3.08. The drainage density of the watershed is 3.63 km/sq km and it indicates the closeness of spacing of channels. The systematic analysis of various parameters in GIS helps in better understanding the soil resources distribution, watersheds prioritization, planning and management.

  19. CT morphometric analysis to determine the anatomical basis for the use of transpedicular screws during reconstruction and fixations of anterior cervical vertebrae.

    Directory of Open Access Journals (Sweden)

    Chun Chen

    Full Text Available BACKGROUND: Accurate placement of pedicle screw during Anterior Transpedicular Screw fixation (ATPS in cervical spine depends on accurate anatomical knowledge of the vertebrae. However, little is known of the morphometric characteristics of cervical vertebrae in Chinese population. METHODS: Three-dimensional reconstructions of CT images were performed for 80 cases. The anatomic data and screw fixation parameters for ATPS fixation were measured using the Mimics software. FINDINGS: The overall mean OPW, OPH and PAL ranged from 5.81 to 7.49 mm, 7.77 to 8.69 mm, and 33.40 to 31.13 mm separately, and SPA was 93.54 to 109.36 degrees from C3 to C6, 104.99 degrees at C7, whereas, 49.00 to 32.26 degrees from C4 to C7, 46.79 degrees at C3 (TPA. Dl/rSIP had an increasing trend away from upper endplate with mean value from 1.87 to 5.83 mm. Dl/rTIP was located at the lateral portion of the anterior cortex of vertebrae for C3 to C5 and ipsilateral for C6 to C7 with mean value from -2.70 to -3.00 mm, and 0.17 to 3.18 mm. The entrance points for pedicular screw insertion for C3 to C5 and C6 to C7 were recommended -2∼-3 mm and 0-4 mm from the median sagittal plane, respectively, 1-4 mm and 5-6 mm from the upper endplate, with TPA being 46.79-49.00 degrees and 40.89-32.26 degrees, respectively, and SPA being 93.54-106.69 degrees and 109.36-104.99 degrees, respectively. The pedicle screw insertion diameter was recommended 3.5 mm (C3 and C4, 4.0 mm (C5 to C7, and the pedicle axial length was 21-24 mm for C3 to C7 for both genders. However, the ATPS insertion in C3 should be individualized given its relatively small anatomical dimensions. CONCLUSIONS: The data provided a morphometric basis for the ATPS fixation technique in lower cervical fixation. It will help in preoperative planning and execution of this surgery.

  20. Magnetic resonance imaging in schizophrenia: a morphometric study; Ressonancia magnetica na esquizofrenia: um estudo morfometrico

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Claudio Campi de [Sao Paulo Univ., SP (Brazil). Instituto do Coracao (InCor). Secao de Ressonancia Magnetica]. E-mail: campi@uol.com.br

    2001-06-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  1. Morphological changes of carotid bodies in acute respiratory distress syndrome: a morphometric study in humans

    Directory of Open Access Journals (Sweden)

    Vinhaes E.N.G.

    2002-01-01

    Full Text Available Carotid bodies are chemoreceptors sensitive to a fall of partial oxygen pressure in blood (hypoxia. The morphological alterations of these organs in patients with chronic obstructive pulmonary disease (COPD and in people living at high altitude are well known. However, it is not known whether the histological profile of human carotid bodies is changed in acute clinical conditions such as acute respiratory distress syndrome (ARDS. The objective of the present study was to perform a quantitative analysis of the histology of carotid bodies collected from patients who died of ARDS. A morphometric study of carotid bodies collected during routine autopsies was carried out on three groups: patients that died of non-respiratory diseases (controls, N = 8, patients that presented COPD and died of its complications or associated diseases (N = 7, and patients that died of ARDS (N = 7. Morphometric measurements of the volume fraction of clusters of chief cells were performed in five fields on each slide at 40X magnification. The numerical proportion of the four main histological cell types (light, dark, progenitor and sustentacular cells was determined analyzing 10 fields on each slide at 400X magnification. The proportion of dark cells was 0.22 in ARDS patients, 0.12 in controls (P<0.001, and 0.08 in the COPD group. The proportion of light cells was 0.33 (ARDS, 0.44 (controls (P<0.001, and 0.36 (COPD. These findings suggest that chronic and acute hypoxia have different effects on the histology of glomic tissue.

  2. Morphometric study of the Habo dome, Kachchh, Gujarat, India: implications on neotectonic activity

    Science.gov (United States)

    Bhattacharjee, N.; Mohanty, S. P.

    2017-12-01

    The Kachchh Basin of western India was developed during the separation of the Indian plate from the Gondwanaland in Mesozoic. Series of E-W striking master faults were generated during this extensional phase. The collision of the Indian and Eurasian plates in Eocene time resulted in the change of stress regime to a compressional setting when the built-up stress developed NNW-SSE to NNE-SSW striking transverse faults and reactivated the earlier E-W master faults. The present work was carried out in the Habo dome, located in the central part of the Kachchh Basin, to analyse the morphometric features such as the bifurcation ratio, circulation ratio, drainage texture, asymmetric factor, hypsometric indices and mountain front sinuosity of selected sub-watersheds of the area to understand the effects of fault reactivation and neotectonic activities on the geometry of the dome. Shuttle Radar Topographic Mission (SRTM) Digital Elevation Model (DEM) data were used to extract drainage network for morphometric analysis of the Kaswati, Khari, and Pur river basins. The study area is elliptical in outline with the long axis trending approximately E-W. The evolution of this domal structure is interpreted to be the result of fault-bound nature of the block. The northern slope of the dome is bound by the Kachchh Mainland Fault and the eastern and western boundaries are marked by transverse faults. The undulating topography was developed by differential movements along several transverse faults striking NW-SE, N-S, and NE-SW. The earlier interpretation of laccolith intrusion into the sedimentary rocks is not supported by the data analysis and field mapping. Stress propagations from the Himalayan range in the northeast and Sulaiman range in the northwest are identified to be the causative factor for historical seismicity and drainage anomalies in the area. Keywords: Basin morphometry, Geographical Information System, Lineament patterns, Kachchh basin, Neotectonics, Fault reactivation

  3. Heritability of face shape in twins: a preliminary study using 3D stereophotogrammetry and geometric morphometrics

    Directory of Open Access Journals (Sweden)

    Seth M. Weinberg

    2013-11-01

    Full Text Available Introduction: Previous research suggests that aspects of facial surface morphology are heritable.  Traditionally, heritability studies have used a limited set of linear distances to quantify facial morphology and often employ statistical methods poorly designed to deal with biological shape.  In this preliminary report, we use a combination of 3D photogrammetry and landmark-based morphometrics to explore which aspects of face shape show the strongest evidence of heritability in a sample of twins. Methods: 3D surface images were obtained from 21 twin pairs (10 monozygotic, 11 same-sex dizygotic.  Thirteen 3D landmarks were collected from each facial surface and their coordinates subjected to geometric morphometric analysis.  This involved superimposing the individual landmark configurations and then subjecting the resulting shape coordinates to a principal components analysis.  The resulting PC scores were then used to calculate rough narrow-sense heritability estimates. Results: Three principal components displayed evidence of moderate to high heritability and were associated with variation in the breadth of orbital and nasal structures, upper lip height and projection, and the vertical and forward projection of the root of the nose due to variation in the position of nasion. Conclusions: Aspects of facial shape, primarily related to variation in length and breadth of central midfacial structures, were shown to demonstrate evidence of strong heritability. An improved understanding of which facial features are under strong genetic control is an important step in the identification of specific genes that underlie normal facial variation.

  4. Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT

    Science.gov (United States)

    Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Sedlmair, Martin; Choudhury, Kingshuk Roy; Pezeshk, Aria; Sahiner, Berkman; Samei, Ehsan

    2017-09-01

    Virtual nodule insertion paves the way towards the development of standardized databases of hybrid CT images with known lesions. The purpose of this study was to assess three methods (an established and two newly developed techniques) for inserting virtual lung nodules into CT images. Assessment was done by comparing virtual nodule volume and shape to the CT-derived volume and shape of synthetic nodules. 24 synthetic nodules (three sizes, four morphologies, two repeats) were physically inserted into the lung cavity of an anthropomorphic chest phantom (KYOTO KAGAKU). The phantom was imaged with and without nodules on a commercial CT scanner (SOMATOM Definition Flash, Siemens) using a standard thoracic CT protocol at two dose levels (1.4 and 22 mGy CTDIvol). Raw projection data were saved and reconstructed with filtered back-projection and sinogram affirmed iterative reconstruction (SAFIRE, strength 5) at 0.6 mm slice thickness. Corresponding 3D idealized, virtual nodule models were co-registered with the CT images to determine each nodule’s location and orientation. Virtual nodules were voxelized, partial volume corrected, and inserted into nodule-free CT data (accounting for system imaging physics) using two methods: projection-based Technique A, and image-based Technique B. Also a third Technique C based on cropping a region of interest from the acquired image of the real nodule and blending it into the nodule-free image was tested. Nodule volumes were measured using a commercial segmentation tool (iNtuition, TeraRecon, Inc.) and deformation was assessed using the Hausdorff distance. Nodule volumes and deformations were compared between the idealized, CT-derived and virtual nodules using a linear mixed effects regression model which utilized the mean, standard deviation, and coefficient of variation (Mea{{n}RHD} , ST{{D}RHD} and C{{V}RHD}{) }~ of the regional Hausdorff distance. Overall, there was a close concordance between the volumes of the CT-derived and

  5. Morphometric study of uninvolved rectal mucosa 10 cm and 20 cm away from the malignant tumor.

    Science.gov (United States)

    Despotović, Sanja Z; Milićević, Novica M; Milosević, Dragoslav P; Despotović, Nebojsa; Erceg, Predrag; Bojić, Bozidar; Bojić, Danijela; Svorcan, Petar; Mihajlović, Gordana; Dorđević, Jelena; Lalić, Ivana M; Milićević, Zivana

    2014-02-01

    Recently, many details of the interplay between tumor cells and tumor-associated stromal elements leading to the progression of malignant disease were elucidated. In contrast, little is known about the role of uninvolved stromal tissue in the remote surrounding of the malignant tumor. Therefore, we performed a computer-aided morphometric study of rectal mucosa in samples taken 10 cm and 20 cm away from the malignant tumor during endoscopic examination of 23 patients older than 60 years. The samples of rectal mucosa from 10 healthy persons of corresponding age subjected to diagnostic rectoscopy during active screening for asymptomatic cancer were used as control. All structural elements of the rectal mucosa were studied and the number of nucleated cells in the lamina propria per 0.1 mm² of tissue was assessed. Our study revealed a reduced number of cells in the lamina propria of the rectal mucosa 10 cm and 20 cm away from the tumor lesion in both male and female patients. The decreased mucosal height and increased crypt number were registered in female patients 10 cm away from the tumor. The connective tissue of lamina propria showed a disorderly organization: the collagen fibers were frail, loosely arranged and signs of tissue edema were present. Small blood vessels and capillaries were much more frequently seen than in healthy tissue. Our results demonstrate the complex interactions between the cancer and remote mucosal tissue of the affected organ.

  6. Local Application of Growth Hormone to Enhance Osseointegration in Osteoporotic Bones: A Morphometric and Densitometric Study.

    Science.gov (United States)

    Martin-Monge, Elena; Tresguerres, Isabel F; Clemente, Celia; Tresguerres, Jesús Af

    The aim of this study was to assess the effect of local application of growth hormone on osseointegration of dental implants inserted in osteoporotic bones. Twenty female New Zealand rabbits were used in this study. Ten were ovariectomized and fed a low-calcium diet for 6 weeks, and the others remained intact. A titanium implant was inserted into each tibia, in both groups. In half of the rabbits, 2 IU of growth hormone was placed into the ostectomy prior to the implant insertion. Two weeks after implant surgery, all animals were sacrificed. Tibiae were dissected from soft tissues, and included in methacrylate to be studied under light microscopy. Bone-to-implant contact (BIC) and bone mineral density (BMD) were measured by morphometric and densitometric analysis, respectively. Multifactorial analysis of variance (ANOVA) was used for statistical evaluation. P growth hormone was able to increase the BIC in the ovariectomized group, with statistically significant differences with respect to the control group (P growth hormone at the moment of titanium implant insertion in rabbit tibiae significantly enhanced the BIC around titanium implants 15 days after the implantation in this experimental osteoporotic animal model, without affecting the BMD.

  7. Morphometric and functional alterations of amygdale and hippocampus in patients with depression: a MRI study

    International Nuclear Information System (INIS)

    Wang Dongqing; Li Yuefeng; Luo Yifeng

    2011-01-01

    Objective: To explore the morphometric and functional alterations of amygdale and hippocampus in patients with depression by anatomical and functional MRI, and try to reveal the pattern and pathogenesis of the changes in depression. Methods: Sixty patients (divided equally into mild, moderate and major groups according to patient's scores of HAMD) and 20 healthy control groups were scanned using T 1 WI and fMRI. The outlines of hippocampus and amygdale were drawn manually by observer and the volumes were calculated and normalized subsequently. Functional MRI was processed using SPM5 and individual activation map was got subsequently. Dunnett-t test and Pearson correlation analysis were separately used to analyze the morphometric and functional changes and the correlations between cerebral changes and clinical severity. Results: The hippocampal volumes of control groups were 2296±202 left for left side and 2283±199 for right side. The hippocampal volumes of depressive patients were smaller than those of control groups, especially for the major group (left 1978±176, Dunnett-t =-10.0, P 0.05, right 2210±191, Dunnett-t =-1.6, P>0.05). The amygdale's volumes of control groups was 1762±185, the right was 1749±182, while those in patient group reduced along with the patient's condition, i. e., the mild groups (left 1992±200, Dunnett-t =4.8, P<0.01, right 1989±191, Dunnett-t =5.0, P<0.001), the moderate groups (left 1889±192, Dunnett-t =2.8, P<0.05, right 1896±195, Dunnett-t =2.8, P<0.05), and the major groups (left 1539±178, Dunnett-t =-6.8, P<0.01, right 1543±180, Dunnett-t =-7.0, P< 0.01). For fMRI study, patient group demonstrated more activation of the amygdale and hippocampus under the stimulations of negative images than controls. Furthermore, the strengthens of activation decreased along with the patient's condition, i. e., the major ones showed the weakest activation among the patients, though it was higher than that of control group. In patient group

  8. Acute pulmonary emphysema in death by hanging: a morphometric digital study.

    Science.gov (United States)

    Castiglioni, Claudia; Baumann, Pia; Fracasso, Tony

    2016-09-01

    Acute pulmonary emphysema (APE) has been described in cases of mechanical asphyxia such as ligature or manual strangulation but not in cases of hanging. In this study, we wanted to verify by morphometric digital analysis of lung tissue whether APE occurs in death by hanging.We investigated 16 cases of hanging (eight complete, eight incomplete), 10 cases of freshwater drowning (positive control group), and 10 cases of acute external bleeding (negative control group). Tissue sections were obtained from each pulmonary lobe. For each slide, five fields were randomly selected. The area of every alveolar space was measured by image analysis software. The mean alveolar area (MAA) was calculated for each group.In incomplete hanging, MAA was significantly higher than that observed in complete hanging and similar to the one observed in freshwater drowning.APE in cases of incomplete hanging can be considered as a sign of vitality. The high number of conditions that can cause alveolar distension (that were excluded in this study) limits the applicability of this vital sign in the routine forensic practice.

  9. Use of morphometric analysis and self-organizing maps for alluvial fan classification: case study on Ostorankooh altitudes, Iran

    International Nuclear Information System (INIS)

    Mokarram, Marzieh; Seif, Abdollah; Sathyamoorthy, Dinesh

    2014-01-01

    The aim of this study is to classify alluvial fans formed by high-gradient braided streams and torrents that discharge into the Oshtorankook altitudes in the Lorestan province, Iran. The morphology of the fans and their watershed is quantitatively described through estimated morphometric parameters. For relationships between geomorphological features of the fans and their drainage basins, self-organizingmaps (SOM) were used. In SOM, according to both qualitative data and morphometric variables, the clustering tendency of alluvial fans was investigated using 15 alluvial fans parameters. The results of the analysis showed that several morphologically different fan types were recognizedbased on their geomorphological characteristics in the study area. A strong positive relationship was found between the drainage basin area and size of the fan with a simple power function. In addition, the relationship between fan slope and drainage area was found to be negative and moderately strong with a simple power function

  10. Morphometric study on age-dependent pulmonary lesions in rats exposed to nitrogen dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Kyono, H.; Kawai, K.

    1982-01-01

    Electronmicroscopic morphometry was performed on lung of 1, 3, 12 and 21 months-old rats exposed to 0.1, 0.5, 3 and 10 ppm nitrogen dioxide (NO/sub 2/) continuously for one month. The rats used in this experiment were all supplied at one time from one colony and kept under a barrier system until exposure. Effects of aging on the responses of lungs to NO/sub 2/ were studied by comparing the dose-effect reaction patterns among the age groups. A trend of dose-dependent increase of arithmetic mean thickness of air-blood barrier was found in all age groups examined. The response of lung to NO/sub 2/ exposure showed age-related differences. Based on the morphometric index, the response declines from 1 to 12 months, but increases again in 21-months-old rats. The compartmental components of alveolar wall tissue such as type I epithelial cells, type II epithelial cells, interstitial cells, interstitial matrix and capillary endothelium appeared to have various degrees of response due to both age at onset of exposure and NO/sub 2/ concentration, resulting in the appearance of varying stages in impairment or repair. Accordingly, the response of each compartmental component of lung to the concentrations of NO/sub 2/ did not always exhibit a simple dose-dependent increase or decrease but sometimes indicated a multiphasic reaction pattern.

  11. A morphometric study on regeneration of the human liver following hepatectomy by computed tomography

    International Nuclear Information System (INIS)

    Okamoto, Eizo; Yamanaka, Naoki

    1983-01-01

    A morphometric study has been carried out on the restoration of remnant hepatic volume (RHV) after various extent of hepatectomy in humans by serial computed tomography in 15 non-cirrhotics, 14 cirrhotics and 7 hepatic failures. Restoration of RHV has been observed only in patients with more than 10 % hepatectomy. In non-cirrhotics with major hepatectomy (RHV less than 600 cm 3 ), an early rapid increasing phase was followed by a subsequent decreasing phase and then a slow increasing phase. Decreasing phase was absent in most non-cirrhotics with moderate hepatectomy (RHV 600-1000 cm 3 ) and cirrhotics. Daily increase rate of RHV during the first posthepatectomy month was inversely proportional to the RHV at operation restoring invariably to 800-900 cm 3 at the end of this month. Termination of regeneration was within 6 months in non-cirrhotics with moderate hepatectomy and from 6 to 12 months in those with major hepatectomy. It was delayed in cirrhotics. RHV has finally attained to an average of 90 % of preoperative hepatic volume in non-cirrhotics and 81 % in cirrhotics. The restoration of RHV was extremely poor in hepatic failures. (author)

  12. Study of needles morphometric indexes in Scots pine trees in 25 years after the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Makarenko, E.S. [Russian Institute of Agricultural Radiology and Agroecology, 249030, Obninsk, Russia, Kievskoe shosse 109 km (Russian Federation); Oudalova, A.A. [Russian Institute of Agricultural Radiology and Agroecology, 249030, Obninsk, Russia, Kievskoe shosse 109 km (Russian Federation); Obninsk Institute of Nuclear Power Engineering, National Research Nuclear University MEPhI, 249032, Obninsk, Russia, Studgorodok, 1 (Russian Federation)

    2014-07-01

    Long-term observations of coniferous tree populations within areas contaminated after radiation accidents provide unique information on biological consequences in plant populations from chronic radiation exposure. Many studies have been performed in a near zone of the Chernobyl NPP where in the primary period after the accident non-human biota was exposed to high doses, and dose rates essentially exceed natural radiation background up to now. Of special interest, however, are biological effects in plant and animal populations inhabiting territories with less pronounced exposure levels. Pine is especially important species for investigation in the field of environment radiation protection since it is included in the ICRP reference plants and animals list as one of the most radiosensitive plant species. The aim of this work was to estimate biological effects of chronic radiation impact for pine trees using needle indexes as test-functions. Study-sites are situated in the Bryansk Region of Russia contaminated after the Chernobyl accident. Scots pine populations under study have been growing in the radioactively contaminated areas over 20 years. In 2011 and 2013 samples of 2-years old needle were collected at 6 study-sites. {sup 137}Cs activities in soils at the time of sampling were from 1.57 to 96.9 kBq/kg. Estimated annual doses to pine tree crowns were calculated in a range of 7-130 mGy. Length and weight of the needles were measured, and necrosis rank was determined. Developmental disturbances were estimated via indexes of fluctuating asymmetry calculation for length (FA{sub L}) and weight (FA{sub W}) characteristics. Needle length of the Scots pine from study-sites ranged from 64.8 to 80.2 mm. Needle weight ranged from 18.2 to 30.5 mg, and was higher at radioactively contaminated sites in comparison to reference populations. Correlation of morphometric parameters and radiation impact was, however, statistically insignificant. Normal needle appeared with frequency

  13. Clinical study of CT colonography

    International Nuclear Information System (INIS)

    Nakazawa, Saburo; Hattori, Toshiyuki; Inui, Kazuo

    2011-01-01

    We studied the usefulness of CT colonography (CTC) for colon cancer diagnosis. CTC and optical colonoscopy were performed for 150 cases mainly including patients with a positive fecal occult blood test (FOBT). The results were compared and analyzed. The following are the final diagnoses given to the patients: advanced colon cancer: 41 cases; early cancer: 25 cases; adenoma: 74 cases; hyperplasia: 3 cases; submucosal tumor: 1 case; and no lesion: 6 cases. In terms of diagnostic performance of CTC, accuracy was found to be 96%, sensitivity was found to be 97.9%, and specificity was found to be 50%. Cancer stage-specific sensitivity was as follows: advanced colon cancer: 100%; early cancer: 96.3%; adenoma: 71.2%; and hyperplasia: 47.4%. Lesion site-specific sensitivity was as follows: caecum: 76.2%; ascending colon: 57.6%; transverse colon: 66.2%; descending colon: 83.3%; sigmoid colon: 85.1%; and rectum: 78.0%. Lesion size-specific sensitivity was as follows: 2 to 5 mm: 56.7%; 6 to 9 mm: 88.1%; 10 mm or more: 92.5%; and 6 mm or more: 90.9%. Therefore, the diagnostic sensitivity of CTC was confirmed to be high. The results suggest that CTC would be useful for colon cancer screening. (author)

  14. The prostate after administration of anabolic androgenic steroids: a morphometrical study in rats.

    Science.gov (United States)

    Vargas, Rafael Arêas; Oliveira, Leonardo Pires; Frankenfeld, Stephan; Souza, Diogo Benchimol de; Costa, Waldemar Silva; Favorito, Luciano Alves; Sampaio, Francisco José Barcellos

    2013-01-01

    Many adverse effects have been associated with abuse of anabolic-androgenic steroids (AAS), including disorders of the urogenital tract. The objective of this study is to analyze the morphological modifications in the prostate ventral lobe of pubertal and adult rats chronically treated with AAS, using morphometric methods. We studied 39 male Wistar rats weighing between 400 g and 550 g. The rats were divided into four groups: (a) control rats, with 105 days of age (C105) (n = 7); (b) control rats with 65 days of age (C65) (n = 9), injected only with the vehicle (peanut oil); (c) treated rats, with 105 days of age (T105) (n = 10) and (d) treated rats with 65 days of age (T65) (n = 13). The treated rats were injected with nandrolone decanoate at a dose of 10 mg.Kg-1 body weight. The steroid hormone and the vehicle were administered by intramuscular injection once a week for eight weeks. The rats were killed at 161 days of age (C105 and T105) and 121 days of age (C65 and T65) and the ventral prostate lobe was dissected and processed for histology. The height of the acinar epithelium, the surface densities of the lumen, epithelium and stroma were observed with X400 magnification using an Olympus light microscope coupled to a Sony CCD video camera, and the images transferred to a Sony monitor KX14-CP1. The selected histological areas were then quantified using the M42 test-grid system on the digitized fields. The data were analyzed with the Graphpad software. To compare the quantitative data in both groups (controls and treated) and the outcomes, Student's t-test was used (p anabolic androgenic steroids in rats promotes structural changes in the prostate. We observed structural changes in the weight, volume and epithelium height of the prostate ventral lobe and a predominance of collagen fibers.

  15. A geometric morphometric study of a Middle Pleistocene cranium from Hexian, China.

    Science.gov (United States)

    Cui, Yaming; Wu, Xinzhi

    2015-11-01

    The Hexian calvarium is one of the most complete and well-preserved Homo erectus fossils ever found in east Asia, apart from the Zhoukoudian specimens. Various methods bracket the age of the Hexian fossil to between 150 and 412 ka (thousands of years ago). The Hexian calvarium has been considered to be H. erectus given its morphological similarities to Zhoukoudian and Javan H. erectus. However, discussion continues regarding the affinities of the Hexian specimen with other H. erectus fossils. The arguments mainly focus on its relationships to other Asian H. erectus fossils, including those from both China and Java. To better determine the affinities of the Hexian cranium, our study used 3D landmark and semilandmark geometric morphometric techniques and multivariate statistical analyses to quantify the shape of the neurocranium and to compare the Hexian cranium to other H. erectus specimens. The results of this study confirmed the morphological similarities between Hexian and Chinese H. erectus in overall morphology, and particularly in the structure of the frontal bone and the posterior part of the neurocranium. Although the Hexian specimen shows the strongest connection to Chinese H. erectus, the morphology of the lateral neurocranium resembles early Indonesian H. erectus specimens, possibly suggesting shared common ancestry or gene flow from early Indonesian populations. Overall cranial and frontal bone morphology are strongly influenced by geography. Although geographically intermediate between Zhoukoudian and Indonesian H. erectus, the Hexian specimen does not form part of an obvious morphological gradient with regard to overall cranial shape. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. MORPHOMETRIC STUDY OF THE AREOLAR SPACE BETWEEN THE GREAT VESSELS AND THE LUMBAR SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2015-12-01

    Full Text Available Objective : This work aims to study the areolar space anterior to the lumbar spine, and also the positioning of the large vessels focusing a lateral approach. Methods :This is a morphometric study of 108 cases based on T2 weighted-MRI images in the supine position. The following measurements were performed: lumbar and segmental lordosis; anteroposterior disc diameter; space between the disc/vertebral body and the vessels; bifurcation between the abdominal aorta and the common iliac veins confluence in relation to the lumbar level. Results :The areolar space with respect to the iliac veins, and with the vena cava increased cranially (p<0.001, starting from average 0.6mm at L4-L5 and reaching 8.4mm at L2, while the abdominal aorta showed no increase or decrease pattern across the different levels (p=0.135 ranging from 1.8 to 4.6mm. The diameter of the discs increased distally (p<0.01 as well as the lordosis (p<0.001. The disc diameter was 11% larger when compared to the adjacent vertebral bodies (p<0.001 and that resulted in a smaller distance of the vessels in the disc level than in the level of the adjacent vertebral bodies (p<0.001. The aortic bifurcation was generally ahead of L4 (52% and less frequently at L3-L4 (28% and L4-L5 (18%. The confluence of the veins was usually at the L4-L5 level (38% and at L5 (37%, and less frequently at L4 (26%. Conclusions : There is an identifiable plane between the great vessels and the lumbar spine which is particularly narrow in its distal portion. It is theoretically feasible to reach this plan, handle the anterior complex disc/ALL and protect the great vessels by lateral approach, however, it is challenging.

  17. Micro-computed tomography (μCT) as a novel method in ecotoxicology - determination of morphometric and somatic data in rainbow trout (Oncorhynchus mykiss)

    NARCIS (Netherlands)

    Brinkmann, M.; Rizzo, L.Y.; Lammers, Twan Gerardus Gertudis Maria; Gremse, F.; Schiwy, S.; Kiessling, F.; Hollert, H.

    2016-01-01

    Fish are important sentinel organisms for the assessment of water quality and play a central role in ecotoxicological research. Of particular importance to the assessment of health and fitness of fish stocks in response to environmental conditions or pollution are morphometric (e.g. Fulton's

  18. Morphometrical Study of the Temporal Bone and Auditory Ossicles in Guinea Pig

    Directory of Open Access Journals (Sweden)

    Ahmadali Mohammadpour

    2011-03-01

    Full Text Available In this research, anatomical descriptions of the structure of the temporal bone and auditory ossicles have been performed based on dissection of ten guinea pigs. The results showed that, in guinea pig temporal bone was similar to other animals and had three parts; squamous, tympanic and petrous .The tympanic part was much better developed and consisted of oval shaped tympanic bulla with many recesses in tympanic cavity. The auditory ossicles of guinea pig concluded of three small bones; malleus, incus and stapes but the head of the malleus and the body of incus were fused and forming a malleoincudal complex. The average of morphometric parameters showed that the malleus was 3.53 ± 0.22 mm in total length. In addition to head and handle, the malleus had two distinct process; lateral and muscular. The incus had a total length 1.23 ± 0.02mm. It had long and short crus although the long crus was developed better than short crus. The lenticular bone was a round bone that articulated with the long crus of incus. The stapes had a total length 1.38 ± 0.04mm. The anterior crus(0.86 ± 0.08mm was larger than posterior crus (0.76 ± 0.08mm. It is concluded that, in the guinea pig, the malleus and the incus are fused, forming a junction called incus-malleus, while in the other animals these are separate bones. The stapes is larger and has a triangular shape and the anterior and posterior crus are thicker than other rodents. Therefore, for otological studies, the guinea pig is a good lab animal.

  19. Morphometric Study of the Irradiation Effect on the Cartilage Formation in the Rat Mandibular Condyle

    International Nuclear Information System (INIS)

    Kim, Jeong Hwa; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    1999-01-01

    This study was undertaken to quantitatively estimate the degree of the damage and recovery of the irradiated rat condylar cartilage using the Image Analyzer. Experimental animals were 16 male rats of the Sprague-Dawley strain at the age of 20 day irradiated with the dose of 10 Gy in their head and neck region. Four rats were sacrificed at the each of the following time intervals - 1, 4, 7 and 14 days, respectively. The same number of control group animals were sacrificed at the each age of 21, 24, 27 and 34 days, respectively. The specimens were stained with 0.5% toluidine blue and examined with light microscope. The condylar cartilage was divided into 4 zones; fibrous zone, proliferating zone, upper hypertrophic zone, and lower hypertrophic zone. And then, the proliferating zone was subdivided into 2 layers - upper and lower layer, and upper and lower hypertrophic zone were subdivided into three layers, respectively - upper, middle and lower layer. With the aid of Image Analyzer, morphometric analysis was performed. The thickness, the numerical density of cells, the cell area density, the extracellular matrix area density, the mean area of single cell, the mean area of extracellular matrix per single cell were measured and analysed. In the experimental group, the thickness of the fibrous zone was slightly increased and that of the proliferating zone and the upper and the lower hypertrophic zone was markedly decreased. With time, the thickness of the fibrous zone was gradually increased and that of the proliferating zone and the upper and the lower hypertrophic zone was steadily in the decreased state. The numerical density of cells of the proliferating zone was increased on post-irradiated 1 day, but decreased after post-irradiated 4 day, and that of the upper hypertrophic zone was decreased. The numerical density of cells of the lower hypertrophic zone was decreased in the early stage and then was decreased or not significantly different from that of the control

  20. Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Wouters, Johan; Vercauteren, Tom; De Gersem, Werner; Duprez, Fréderic; De Neve, Wilfried; Van Hoof, Tom

    2015-01-01

    Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result

  1. A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image

    International Nuclear Information System (INIS)

    Han, Seung Yun; Lee, Sun Bok; Oh, Sung Ook; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; Kim, Jong Dae

    2003-01-01

    To evaluate the relationship between morphometric analysis of microstructure from digital radiographic image and trabecular bone strength. One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI(100 x 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p<0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  2. Morphometric study of the upper intercostal nerves: practical application for neurotizations in traumatic brachial plexus palsies.

    Science.gov (United States)

    Asfazadourian, H; Tramond, B; Dauge, M C; Oberlin, C

    1999-01-01

    The aim of the study was a morphometric evaluation of the intercostal nerves at different levels along their course in order to determine their adequacy in neurotizing the recipient nerves. The intercostal nerves were harvested from 5 cadavers. A biopsy of the nerve was obtained at 2 levels for each nerve in the parasternal region and at the level of the mid-axillary line. The musculocutaneous nerve was isolated at its origin from the lateral cord. Each harvested specimen was embedded in paraffin and sections were made using a microtome. These sections were then stained histochemically using HPS (Hematein, Phloxine, Safran). Real-time digitalisation of the video image under the microscope was performed. The sum of the different fascicular zones is the effective sensorimotor surface of the nerve at the level being studied. Direct suture of the upper three intercostal nerves to the musculocutaneous nerve is always possible upto the axillary fossa. The sixth intercostal nerve can be delivered upto this level in only 50% of cases without dissection of the musculocutaneous nerve upto its entry into the coracobrachialis. The musculocutaneous nerve presents a mean surface area of 2.64 mm2 while the nerve to the biceps has a mean surface area of 0.34 mm2 i.e. a ration of 1/8. The mean surface area of the intercostal nerves at the parasternal level is 0.23 mm2 while that at the axillary level is 0.34 mm2. Thus a loss of 33% in surface area occurs between the axillary and the parasternal levels. Our study confirms the insufficiency between the surface area of the intercostal nerves and the different nerve trunks to be neurotized. The relationship between the surface area of the musculocutaneous nerve and the three intercostal nerves is 26.72% with a minimum of 17.2%. If a fourth intercostal nerve is added, this ratio nerves appears to be a superior technique. We were able to deliver the sixth intercostal nerve for a direct suture to the musculocutaneous nerve in only half

  3. Morphometrical study of the human kidney. Radiodiagnosis and patological anatomy applications

    International Nuclear Information System (INIS)

    Sampaio, J.B.; Lacerda, C.A.M. de

    1987-01-01

    A morphometrical estimate was made on 100 human kidneys obtained by necropsies. The results of the renal measurements showed the averages of 11.06cm long, 6.24cm wide for the superior pole, 5.42cm wide for the inferior pole, 3.26cm thickness, and 119.48g weight. The left kidney presented a greater lenght, greater width, greater thickness and greater weight than the kidney. The statistical analysis of the correlation between several indices is presented. (author) [pt

  4. Effect of Urtica dioica on morphometric indices of kidney in streptozotocin diabetic rats--a stereological study.

    Science.gov (United States)

    Golalipour, Mohammad Jafar; Gharravi, Anneh Mohammad; Ghafari, Sorya; Afshar, Mohammad

    2007-11-01

    The aim of the present study was to investigate the effect of Urtica dioica on Morphometric indices of kidney in diabetic rats. Thirty male adult albino wistar rats of 125-175 g divided into control, diabetic and Urtica dioica treatment groups. In treatment Group, diabetic rats received 100 mg kg(-1) daily hydroalcoholic extract of U. dioica intraperitoneally for 4 weeks. After the animals had been sacrified, the kidneys were removed and fixed by formaldehyde, cut horizontally into 1 mm slices and processed, Stained with H and E. Stereological study performed using light microscope and the image projected on a table of olysa software. Cavalieri principle was used to estimate the volume of cortex, medulla and whole kidney. All the grouped data statistically evaluated using Student's t-test, expressed as the Mean +/- SE. Ration of kidney weight/body weight in diabetes (0.51) and diabetes-extract group (0.67) were higher then control group (0.42). Ratio of kidney volume/body weight in diabetes (350) and diabetes-extract group (348) were higher then control group (323). Volume Ratio of cortex/medulla in diabetes-extract group (1.65) was higher then control (1.34) and diabetes group (1.33). Glomerular area and diameter and proximal tubule diameter in diabetes-Extract group was higher than control and diabetes groups. This study revealed that Urtica dioica has no effect on renal morphometric indices in induced diabetic rats.

  5. Morphometric study of newly emerged unmated queens of honey bee Apis mellifera L. in Ismailia Governorate, Egypt

    Directory of Open Access Journals (Sweden)

    S.M. Kamel

    2013-06-01

    Full Text Available Recently, morphometric analysis is being a very good tool for identification of honey bee races and characterization of genetic materials. This fact has motivated the present work to investigate the effects of two grafting methods, three types of artificial queen wax cups and four periods of queen rearing on some morphological characters of newly emerged queens. The developed technique used in the present study depends on the integration between Scanner unit and Photoshop program, called Scan Photo Method (SPM. The measurements of 23 morphological characteristics of reared queens were estimated by using SPM. Results indicated significant differences between periods in the measurements of the studied characteristics on forewing such as cubital index, distance C, distance D, radial field, inner wing length, inner wing width, dumb bell index, distance I, II, III and IV, except cubital A and cubital B. Regarding the effects of cup types and grafting methods, data also revealed significant differences in all measurements of studied characteristics, except tibial length, hind wing length, cubital B, radial field and distance IV. Further works in this area were recommended to find out a relation between some morphometric characters and important of some quantitative characters.

  6. DNA-based and geometric morphometric analysis to validate species designation: a case study of the subterranean rodent Ctenomys bicolor.

    Science.gov (United States)

    Stolz, J F B; Gonçalves, G L; Leipnitz, L; Freitas, T R O

    2013-10-25

    The genus Ctenomys (Rodentia: Ctenomyidae) shows several taxonomic inconsistencies. In this study, we used an integrative approach including DNA sequences, karyotypes, and geometric morphometrics to evaluate the taxonomic validity of a nominal species, Ctenomys bicolor, which was described based on only one specimen in 1912 by Miranda Ribeiro, and since then neglected. We sampled near the type locality assigned to this species and collected 10 specimens. A total of 820 base pairs of the cytochrome b gene were sequenced and analyzed together with nine other species and four morphotypes obtained from GenBank. Bayesian analyses showed that C. bicolor is monophyletic and related to the Bolivian-Matogrossense group, a clade that originated about 3 mya. We compared the cranial shape through morphometric geometrics of C. bicolor, including the specimen originally sampled in 1912, with other species representative of the same phylogenetic group (C. boliviensis and C. steinbachi). C. bicolor shows unique skull traits that distinguish it from all other currently known taxa. Our findings confirm that the specimen collected by Miranda Ribeiro is a valid species, and improve the knowledge about Ctenomys in the Amazon region.

  7. Morphometric changes of whole brain in patients with alcohol addiction: a voxel-based morphometry study

    International Nuclear Information System (INIS)

    Li Jinfeng; Chen Zhiye; Ma Lin

    2011-01-01

    Objective: To evaluate morphometric changes of brain in patients with alcohol addiction by voxel-based morphometry. Methods: Fifteen patients with alcohol addiction and 15 health controls were recruited and underwent fluid attenuated inversion recovery (FLAIR) and 3D fast spoiled gradient echo (FSPGR) T 1 -weighted sequences on a 3.0 T MRI system. 3D FSPGR T 1 structure images were normalized, segmented and smoothed, and then underwent voxel-based morphometry. An ANCOVA was applied with age, body mass index (BMI), and education years as covariates because of exact sex match. A statistical threshold of P 0.05). Conclusions: Regional gray and white matter atrophy can be the initial changes in patients with alcohol addiction and the frontal region is a relative specific damaged brain region. VBM has a potential value for the detection of subtle brain atrophy in patients with alcohol addiction. (authors)

  8. Experimental chronic entrapment of the sciatic nerve in adult hamsters: an ultrastructural and morphometric study

    Directory of Open Access Journals (Sweden)

    Prinz R.A.D.

    2003-01-01

    Full Text Available Entrapment neuropathy is a group of clinical disorders involving compression of a peripheral nerve and interference with nerve function mostly through traction injury. We have investigated the chronic compression of peripheral nerves as an experimental procedure for detecting changes in ultrastructural nerve morphology. Adult hamsters (Mesocricetus auratus, N = 30 were anesthetized with a 25% pentobarbital solution and received a cuff around the right sciatic nerve. Left sciatic nerves were not operated (control group. Animals survived for varying times (up to 15 weeks, after which they were sacrificed and both sciatic nerves were immediately fixed with a paraformaldehyde solution. Experimental nerves were divided into segments based upon their distance from the site of compression (proximal, entrapment and distal. Semithin and ultrathin sections were obtained and examined by light and electron microscopy. Ultrastructural changes were qualitatively described and data from semithin sections were morphometrically analyzed both in control and in compressed nerves. We observed endoneurial edema along with both perineurial and endoneurial thickening and also the existence of whorled cell-sparse structures (Renaut bodies in the subperineurial space of compressed sciatic nerves. Morphometric analyses of myelinated axons at the compression sites displayed a remarkable increase in the number of small axons (up to 60% in comparison with the control axonal number. The distal segment of compressed nerves presented a distinct decrease in axon number (up to 40% comparatively to the control group. The present experimental model of nerve entrapment in adult hamsters was shown to promote consistent histopathologic alterations analogous to those found in chronic compressive neuropathies.

  9. Watershed-based Morphometric Analysis: A Review

    Science.gov (United States)

    Sukristiyanti, S.; Maria, R.; Lestiana, H.

    2018-02-01

    Drainage basin/watershed analysis based on morphometric parameters is very important for watershed planning. Morphometric analysis of watershed is the best method to identify the relationship of various aspects in the area. Despite many technical papers were dealt with in this area of study, there is no particular standard classification and implication of each parameter. It is very confusing to evaluate a value of every morphometric parameter. This paper deals with the meaning of values of the various morphometric parameters, with adequate contextual information. A critical review is presented on each classification, the range of values, and their implications. Besides classification and its impact, the authors also concern about the quality of input data, either in data preparation or scale/the detail level of mapping. This review paper hopefully can give a comprehensive explanation to assist the upcoming research dealing with morphometric analysis.

  10. The morphological and morphometric study of tissues of dentoalveolar system in children with impaired course of the antenatal period

    Directory of Open Access Journals (Sweden)

    Drogomiretskaya M.S.

    2016-03-01

    Full Text Available Anomalies and deformation of dental system in children and adolescents contribute not only to the deterioration of dental health, bat quite often this is the cause of a wide range of somatic pathology. The aim of our study was to determine risk factors of dental system myofunctional disorders in children with impaired course of the antenatal period using morphological and morphometric studies. The changes that have been defined in the organs examined were dystrophic and dyscirculatory and differed in degrees of severity in all parts of the oral cavity. Dystrophic changes were detected in the gums and tongue epithelium. Dyscirculatory disorders were characterized by formation of submucosal edema, development of the vascular bed hyperemia and presence of hemorrhage under the basement membrane of the epithelium and salivary gland stroma. Pronounced changes were recorded in the nerve cells of the oral cavity.

  11. Dosimetry of inhaled plutonium-239 dioxide in rodent lung: a morphometric study

    International Nuclear Information System (INIS)

    Rhoads, K.

    1979-06-01

    Morphometric analysis of rat and hamster lung did not demonstrate any extensive changes in lung composition or structure following inhalation exposure to 239 Pu0 2 at levels near that for maximum tumor yield in rats. The problem of dosimetry for this compound thus appears to be relatively uncomplicated by any major radiation-induced pathological alterations in the lung. Rat and hamster lung were found to be similar in structure and composition, with few significant differences which could be directly related to the different tumor responses. The distribution of 239 Pu0 2 particles was not uniform in all regions of the lung; thus estimation of the dose to specific tissues or regions within the lung requires a correction for this effect. Species differences were found for particle distribution in the subpleural region and major airways, and in the spatial association of particles, both of which may affect the tumor development process. These regions contain the principal target cells for tumor production and serve as foci for the origin of tumors. Different dose distributions within these regions may therefore explain, at least in part, the difference in tumor response to inhaled 239 Pu0 2 for rats and hamsters

  12. CT perfusion study of neck lymph nodes

    International Nuclear Information System (INIS)

    Zhong Jin; Liu Jun; Hua Rui; Qiao Hui; Gong Yi

    2011-01-01

    Objective: To study the CT perfusion features of various lymph nodes in the neck. Methods: Dynamic perfusion CT scanning was performed in 83 neck lymph nodes proved by pathology, including tuberculosis lymph nodes, lymphoma and metastatic lymph nodes. The shapes, blood flow modes, and perfusion parameters of these lymph nodes were compared among 3 groups. Statistical analysis of L/T and CT perfusion parameters was performed by one-way ANOVA and LSD test. Results: The values of MTT of tuberculosis lymph nodes, lymphoma and metastatic lymph nodes were (28.13±5.08), (31.08±5.82), and (11.24±5.31) s, respectively. The MTT of metastatic lymph nodes was statistically lower than that of tuberculosis lymph nodes and lymphoma (P -1 · 100 g -1 , respectively. The values of BV were (24.68±2.84), (25.30±3.16), and (25.15± 8.81) ml·100 g -1 respectively. The values of TTP were (40.90±8.85), (40.67±6.45), and (40.98±6.62) s, respectively. There were no significant differences in L/T, BF, BV and TTP among tuberculosis lymph nodes, lymphoma and metastatic lymph nodes (P>0.05). Conclusion: CT perfusion, especially combination functional imaging with perfusion images may be helpful in judging the nature of neck lymph nodes. (authors)

  13. Effects of peroral supplementation of different forms of zinc on the ruminal mucosa of goat kids – a morphometric study

    Directory of Open Access Journals (Sweden)

    Julius Černík

    2013-01-01

    Full Text Available The aim of the study was to identify the effect of supplementation of various forms of zinc on the ruminal mucosa and dimensions of ruminal papillae in 6-month-old goat kids. The experimental period lasted from weaning to slaughter (4 months. All 20 kids divided into four groups of five animals, were fed with the same feeding dose, which was different only in the quantity and form of zinc. Control group was without additional zinc supplementation (group A, the other groups were supplemented with zinc in the form of ZnO (group B, zinc in the form of chelate (group C and zinc in the form of lactate (group D. Samples for histopathological and morphometric examination were collected after the slaughter of all animals from the bottom of saccus ruminis ventralis everytime from the same place. Significant differences were reported within the comparison of the length of ruminal papillae between groups B and C (P = 0.026 and B and D (P = 0.040, within the comparison of the width of ruminal papillae between groups A and D (P = 0.020 and within the comparison of the intensity of keratinisation of the mucosa of ruminal papillae between groups A and B (P = 0.034, A and C (P = 0.038 and A and D (P = 0.001. Histopathological and morphometric examination of ruminal mucosa indicated that the ruminal papillae of kids supplemented with zinc in the form of ZnO (group B were better developed compared to the other groups. This result indicates better utilisation of the supplemented zinc in the form of ZnO.

  14. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  15. Biometric and morphometric studies of Perna viridis and Perna indica along the southwest coast of India: a statistical approach

    Digital Repository Service at National Institute of Oceanography (India)

    Jayalakshmy, K.V.; Nair, M.; DileepKumar, R.; Vijayan, M.

    morphometric gradient groups (spat and adult), indicating the different phenotypic plasticity between them. The factor scores classified P. indica as a unimodal, positively skewed leptokurtic population and P. viridis as a unimodal, negatively skewed...

  16. Neuroanatomical circuitry associated with exploratory eye movement in schizophrenia: a voxel-based morphometric study.

    Directory of Open Access Journals (Sweden)

    Linlin Qiu

    Full Text Available Schizophrenic patients present abnormalities in a variety of eye movement tasks. Exploratory eye movement (EEM dysfunction appears to be particularly specific to schizophrenia. However, the underlying mechanisms of EEM dysfunction in schizophrenia are not clearly understood. To assess the potential neuroanatomical substrates of EEM, we recorded EEM performance and conducted a voxel-based morphometric analysis of gray matter in 33 schizophrenic patients and 29 well matched healthy controls. In schizophrenic patients, decreased responsive search score (RSS and widespread gray matter density (GMD reductions were observed. Moreover, the RSS was positively correlated with GMD in distributed brain regions in schizophrenic patients. Furthermore, in schizophrenic patients, some brain regions with neuroanatomical deficits overlapped with some ones associated with RSS. These brain regions constituted an occipito-tempro-frontal circuitry involved in visual information processing and eye movement control, including the left calcarine cortex [Brodmann area (BA 17], the left cuneus (BA 18, the left superior occipital cortex (BA 18/19, the left superior frontal gyrus (BA 6, the left cerebellum, the right lingual cortex (BA 17/18, the right middle occipital cortex (BA19, the right inferior temporal cortex (BA 37, the right dorsolateral prefrontal cortex (BA 46 and bilateral precentral gyri (BA 6 extending to the frontal eye fields (FEF, BA 8. To our knowledge, we firstly reported empirical evidence that gray matter loss in the occipito-tempro-frontal neuroanatomical circuitry of visual processing system was associated with EEM performance in schizophrenia, which may be helpful for the future effort to reveal the underlying neural mechanisms for EEM disturbances in schizophrenia.

  17. MicroCT Scan in paleobiology: application to the study of dental tissues

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, M.; Casali, F. E-mail: casali@bo.infn.it; Romani, D.; Bondioli, L.; Macchiarelli, R.; Rook, L

    2004-01-01

    State of the art in paleoanthropological and paleoprimatological research foresees the use of advanced non-destructive investigative approaches. Microcomputed tomography (microCT) is a fundamental tool, since it offers the opportunity to get high quality morphological information with high spatial resolution. We carried out the set-up of an experimental microCT system able to examine paleobiological samples. The equipment can operate on small objects (size up to 3 cm) with a nominal spatial resolution of 30 {mu}m, allowing their 3D volume reconstruction and morphometric analysis. This approach represents a forefront technique in paleobiological studies, successfully employed only in a limited number of advanced research centers. A specific program of microCT analysis has been planned on a sample of human and non-human fossil primate dentitions, in order to assess the specific nature of a number of tooth lesions (e.g. caries versus abrasion). This currently in progress experimental activity represents the first step for the set-up of a research center specifically devoted to the realization of advanced studies in the field of archaeo-paleobiology.

  18. CT studies of brain abscesses in cats

    International Nuclear Information System (INIS)

    Kretzschmar, K.; Wallenfang, T.; Bohl, J.

    1981-01-01

    Cerebral abscesses were produced in 56 cats by introducing staphylococcus aureus into the white matter of one cerebral hemisphere, using a stereotaxic apparatus. The cats were treated with antibiotics and/or steroids. The size and density of the inflammatory process and the abscess ring were measured on postcontrast CT scans. Differences were found depending on the stage of the abscess, but the deviation of values was too great for determining the age of the abscess from one measurement, to be able to apply proper treatment. The size and density of the abscesses were the same on CT whether the animals were treated or not. This was contrary to the clinical picture, the measurements of edema, and the histopathological studies. (orig.)

  19. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  20. Study of bony trabecular characteristics using bone morphometry and micro-CT

    International Nuclear Information System (INIS)

    Song, Young Han; Lee, Wan; Lee, Chang Jin; Ji, Jung Hyun; Lee, Byung Do

    2007-01-01

    The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Twenty-one female (Newzeland, about 16 weeks old, 2.9-3.4 kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Basline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1,2,3,5,6 months respectively, BMD tests were performed on the proximal on the proximal femur by using PIXImus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custom computer program and 2D / 3D bone structure analysis by micro-CT (Skyscan1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD. BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp. Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change

  1. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  2. Geometric and morphometric analysis of fish scales to identity genera, species and populations case study: the Cyprinid family

    Directory of Open Access Journals (Sweden)

    Seyedeh Narjes Tabatabei

    2014-01-01

    Full Text Available Using fish scale to identity species and population is a rapid, safe and low cost method. Hence, this study was carried out to investigate the possibility of using geometric and morphometric methods in fish scales for rapid identification of species and populations and compare the efficiency of applying few and/or high number of landmark points. For this purpose, scales of one population of Luciobarbus capito, four populations of Alburnoides eichwaldii and two populations of Rutilus frisii kutum, all belonging to cyprinid family, were examined. On two-dimensional images of the scales 7 and 23 landmark points were digitized in two separate times using TpsDig2, respectively. Landmark data after generalized procrustes analysis were analyzed using Principal Component Analysis (PCA, Canonical Variate Analysis (CVA and Cluster Analysis. The results of both methods (using 7 and 23 landmark points showed significant differences of the shape of scales among the three species studied (P0.05. The results also showed that few number of landmarks could display the differences between scale shapes. According to the results of this study, it could be stated that the scale of each species had unique shape patterns which could be utilized as a species identification key.

  3. Relationship between personality and gray matter volume in healthy young adults: a voxel-based morphometric study.

    Directory of Open Access Journals (Sweden)

    Fengmei Lu

    Full Text Available This study aims to investigate the neurostructural foundations of the human personality in young adults. High-resolution structural T1-weighted MR images of 71 healthy young individuals were processed using voxel-based morphometric (VBM approach. Multiple regression analyses were performed to identify the associations between personality traits and gray matter volume (GMV. The Eysenck Personality Questionnaire-Revised, Short Scale for Chinese was chosen to assess the personality traits. This scale includes four dimensions, namely, extraversion, neuroticism, psychoticism, and lie. Particularly, we studied on two dimensions (extraversion and neuroticism of Eysenck's personality. Our results showed that extraversion was negatively correlated with GMV of the bilateral amygdala, the bilateral parahippocampal gyrus, the right middle temporal gyrus, and the left superior frontal gyrus, all of which are involved in emotional and social cognitive processes. These results might suggest an association between extraversion and affective processing. In addition, a positive correlation was detected between neuroticism and GMV of the right cerebellum, a key brain region for negative affect coordination. Meanwhile, a negative association was revealed between GMV of the left superior frontal gyrus and neuroticism. These results may prove that neuroticism is related to several brain regions involved in regulating negative emotions. Based on those findings, we concluded that brain regions involved in social cognition and affective process accounted for modulation and shaping of personality traits among young individuals. Results of this study may serve as a basis for elucidating the anatomical factors of personality.

  4. Morphometrics applied to medical entomology.

    Science.gov (United States)

    Dujardin, Jean-Pierre

    2008-12-01

    Morphometrics underwent a revolution more than one decade ago. In the modern morphometrics, the estimate of size is now contained in a single variable reflecting variation in many directions, as many as there are landmarks under study, and shape is defined as their relative positions after correcting for size, position and orientation. With these informative data, and the corresponding software freely available to conduct complex analyses, significant biological and epidemiological features can be quantified more accurately. We discuss the evolutionary significance of the environmental impact on metric variability, mentioning the importance of concepts like genetic assimilation, genetic accommodation, and epigenetics. We provide examples of measuring the effect of selection on metric variation by comparing (unpublished) Qst values with corresponding (published) Fst. The primary needs of medical entomologists are to distinguish species, especially cryptic species, and to detect them where they are not expected. We explain how geometric morphometrics could apply to these questions, and where there are deficiencies preventing the approach from being utilized at its maximum potential. Medical entomologists in connection with control programs aim to identify isolated populations where the risk of reinfestation after treatment would be low ("biogeographical islands"). Identifying them can be obtained from estimating the number of migrants per generation. Direct assessment of movement remains the most valid approach, but it scores active movement only. Genetic methods estimating gene flow levels among interbreeding populations are commonly used, but gene flow does not necessarily mean the current flow of migrants. Methods using the morphometric variation are neither suited to evaluate gene flow, nor are they adapted to estimate the flow of migrants. They may provide, however, the information needed to create a preliminary map pointing to relevant areas where one could

  5. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  6. A morphometric study of bone surfaces and skin reactions after stimulation with static magnetic fields in rats

    Energy Technology Data Exchange (ETDEWEB)

    Linder-Aronson, S.; Lindskog, S. (Karolinska Institutet, Stockholm (Sweden))

    1991-01-01

    The present investigation was undertaken to measure any bone surface changes after stimulation with orthodontic magnets and, furthermore, to examine the soft tissue in immediate contact with the magnets. Both distal parts of the tibial hind legs in six groups of young rats were fitted with devices holding two orthodontic magnets in the experimental legs and similar devices without magnets in the control legs. The animals were killed after 2, 3, and 4 weeks. Morphometric evaluation showed significant increases in resorbing areas after 3 and 4 weeks. Similarly, a reduction was evident in the number of epithelial cells under the areas where the magnets had been applied. These findings indicate that the stimulation of bone resorption in the present study may have been caused by inhibition of the bone-lining osteoblasts. This proposition is supported by the apparent inhibitory effect of the magnetic fields on epithelial recycling that was seen as a reduced thickness of the epithelium under the magnets. Consequently, static magnetic fields should be used with care in orthodontic practice until a more complete understanding of their mechanism of action has been established.

  7. A morphometric study of bone surfaces and skin reactions after stimulation with static magnetic fields in rats.

    Science.gov (United States)

    Linder-Aronson, S; Lindskog, S

    1991-01-01

    The present investigation was undertaken to measure any bone surface changes after stimulation with orthodontic magnets and, furthermore, to examine the soft tissue in immediate contact with the magnets. Both distal parts of the tibial hind legs in six groups of young rats were fitted with devices holding two orthodontic magnets in the experimental legs and similar devices without magnets in the control legs. The animals were killed after 2, 3, and 4 weeks. Morphometric evaluation showed significant increases in resorbing areas after 3 and 4 weeks. Similarly, a reduction was evident in the number of epithelial cells under the areas where the magnets had been applied. These findings indicate that the stimulation of bone resorption in the present study may have been caused by inhibition of the bone-lining osteoblasts. This proposition is supported by the apparent inhibitory effect of the magnetic fields on epithelial recycling that was seen as a reduced thickness of the epithelium under the magnets. Consequently, static magnetic fields should be used with care in orthodontic practice until a more complete understanding of their mechanism of action has been established.

  8. A Small-scale Cross-sectional Study for the Assessment of Cardiorespiratory Fitness in Relation to Body Composition and Morphometric Characters in Fishermen of Araku Valley, Andhra Pradesh, India

    Directory of Open Access Journals (Sweden)

    Pallav Sengupta

    2014-01-01

    Conclusions: Findings of this small-scale population-based study indicated that health and physical fitness of young fishermen is under the influence of both occupational workload and nutritional status, as found by body composition and morphometric characters.

  9. Cytological study of DNA content and nuclear morphometric analysis for aid in the diagnosis of high-grade dysplasia within oral leukoplakia.

    Science.gov (United States)

    Yang, Xi; Xiao, Xuan; Wu, Wenyan; Shen, Xuemin; Zhou, Zengtong; Liu, Wei; Shi, Linjun

    2017-09-01

    To quantitatively examine the DNA content and nuclear morphometric status of oral leukoplakia (OL) and investigate its association with the degree of dysplasia in a cytologic study. Oral cytobrush biopsy was carried out to obtain exfoliative epithelial cells from lesions before scalpel biopsy at the same location in a blinded series of 70 patients with OL. Analysis of nuclear morphometry and DNA content status using image cytometry was performed with oral smears stained with the Feulgen-thionin method. Nuclear morphometric analysis revealed significant differences in DNA content amount, DNA index, nuclear area, nuclear radius, nuclear intensity, sphericity, entropy, and fractal dimension (all P content analysis identified 34 patients with OL (48.6%) with DNA content abnormality. Nonhomogeneous lesion (P = .018) and high-grade dysplasia (P = .008) were significantly associated with abnormal DNA content. Importantly, the positive correlation between the degree of oral dysplasia and DNA content status was significant (P = .004, correlation coefficient = 0.342). Cytology analysis of DNA content and nuclear morphometric status using image cytometry may support their use as a screening and monitoring tool for OL progression. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Morphometric and ultrastructural studies of the effect of infrared laser on rabbit temporo-mandibular joint fibroblasts

    Directory of Open Access Journals (Sweden)

    Ricardo Cornejo Uribe

    2009-06-01

    Full Text Available The infrared laser beams has been successfully used in joint lesions treatment due to its analgesic anti inflamatory and healing action, and on a cellular level, inducing an accentuated synthesis of ATP, activating cellular proliferation and collagen synthesis. Samples of normal-control and irradiated tissue from temporo-mandibular joint disc of rabbit, were obtained, with daily doses of 2 joules/cm²during 10 consecutive days. They were prepared for transmission electronic microscopy.Transmission electronic micrographs of normal and irradiated fibroblasts were obtained with final increase of 11.500 X for morphometric studies with the purpose of quantifying the volumetric fractions of the cellular components pertaining to the mentioned cellular types. Volumetric fractions of the quoted cell corresponding to nucleus, cytoplasm, rough endoplasmatic reticule, eu and heterochromatin were evaluated. In the same manner, the nucleus - cytoplasmatic relation and the area of each cellular type were quantified. The results derived from the morphometric comparative study between the normal and irradiated fibroblasts indicated that there were significant differences with respect to the volumetric fractions of euchromatin and heterochromatin and fundamentally in the cellular areas of both types. On the other hand, the rest of quantified parameters remained constant. It could be concluded that the cellular function reflected in collagen synthesis and secretion remained constant in both cellular types. However, by means of infrared laser stimulations, this fibroblast facilitated protein synthesis, due to high percentage of transcriptionally active euchromatine.O raio laser infravermelho tem sido usado com sucesso no tratamento de lesoes articulares por sua ação analgesica, antinflamatoria e cicatrizante e, ao nivel celular, induzindo acentuada síntese de ATP, ativando a proliferação celular e a síntese do colágeno. Foram obtidas amostras do disco da

  11. Shape change in the atlas with congenital midline non-union of its posterior arch: a morphometric geometric study.

    Science.gov (United States)

    Ríos, Luis; Palancar, Carlos; Pastor, Francisco; Llidó, Susana; Sanchís-Gimeno, Juan Alberto; Bastir, Markus

    2017-10-01

    The congenital midline non-union of the posterior arch of the atlas is a developmental variant present at a frequency ranging from 0.7% to 3.9%. Most of the reported cases correspond to incidental findings during routine medical examination. In cases of posterior non-union, hypertrophy of the anterior arch and cortical bone thickening of the posterior arches have been observed and interpreted as adaptive responses of the atlas to increased mechanical stress. We sought to determine if the congenital non-union of the posterior arch results in a change in the shape of the atlas. This study is an analysis of the first cervical vertebrae from osteological collections through morphometric geometric techniques. A total of 21 vertebrae were scanned with a high-resolution three-dimensional scanner (Artec Space Spider, Artec Group, Luxembourg). To capture vertebral shape, 19 landmarks and 100 semilandmarks were placed on the vertebrae. Procrustes superimposition was applied to obtain size and shape data (MorphoJ 1.02; Klingenberg, 2011), which were analyzed through principal component analysis (PCA) and mean shape comparisons. The PCA resulted in two components explaining 22.32% and 18.8% of the total shape variance. The graphic plotting of both components indicates a clear shape difference between the control atlas and the atlas with posterior non-union. This observation was supported by statistically significant differences in mean shape comparisons between both types of vertebra (patlas is associated with significant changes in the shape of the vertebra. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve: histopathological and morphometric studies

    International Nuclear Information System (INIS)

    Vujaskovic, Zeljko; Powers, Barbara E.; Paardekoper, Gabriel; Gillette, Sharon M.; Gillette, Edward L.; Colacchio, Thomas A.

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate histopathological and histomorphometric changes in the sciatic nerve of dogs, after IORT with or without hyperthermia treatment. Methods and Materials: Young adult beagle dogs were randomized into five groups of 3-5 dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy. Six groups of 4-5 dogs each received IORT doses of 12, 16, 20, 24, or 28 Gy simultaneously with 44 deg. C of intraoperative hyperthermia (IOHT) for 60 min. One group of dogs acted as hyperthermia-alone controls. Two years after the treatment, dogs were euthanized, and histopathological and morphometric analyses were performed. Results: Qualitative histological analysis showed prominant changes such as focal necrosis, mineralization, fibrosis, and severe fiber loss in dogs which received combined treatment. Histomorphometric results showed a significantly higher decrease in axon and myelin and small blood vessels, with a corresponding increase in connective tissue in dogs receiving IORT plus hyperthermia treatment. The effective dose for 50% of nerve fiber loss (ED 50 ) in dogs exposed to IORT only was 25.3 Gy. The ED 50 for nerve fiber loss in dogs exposed to IORT combined with IOHT was 14.8 Gy. The thermal enhancement ratio (TER) was 1.7. Conclusion: The probability of developing peripheral neuropathies in a large animal model is higher when IORT is combined with IOHT, when compared to IORT application alone. To minimize the risk of peripheral neuropathy, clinical treatment protocols for the combination of IORT and hyperthermia should not assume a thermal enhancement ratio (TER) to be lower than 1.5

  13. Circle of willis and its variations; morphometric study in adult human cadavers

    OpenAIRE

    Raghavendra, Shirol VS, Daksha Dixit, Anil Kumar Reddy Y, Desai SP

    2014-01-01

    Background and Objectives: Circle of Willis plays a vital role in collateral circulation and redistribution of blood to all areas of the brain. Variation in circle of Willis is known to cause grave disorders like cerebrovascular disorders, subarachnoid haemorrhage, cerebral aneurysm and schizophrenia. The objectives of the present study are to study the formation and branching pattern of circle of Willis and also to study the distribution of variations. MATERIALS & Methods: The study was cond...

  14. A morphological and morphometric study of jugular foramen in dry skulls with its clinical implications

    Directory of Open Access Journals (Sweden)

    Chandni Gupta

    2014-01-01

    Full Text Available Objective: Jugular foramen of human skull is one of the most interesting foramina. It is a complex bony canal, numerous vital structures, including nerves and vessels are transmitted through it. Most of the intracranial and extra cranial lesions of posterior cranial fossa might affect the structures in jugular foramen in addition to intrinsic abnormalities. As the neurosurgeons have become courageous in approaching this area, so there is a need to become familiar with this area. Hence, the present study was done to examine the anatomy of jugular foramen, including its morphological features and dimensions. Materials and Methods: The study was carried out on 50 dried skulls. 100 jugular foramina were studied on both right and left side of skulls. The length, width of jugular foramen and width and depth of jugular fossa were measured using vernier calipers. Presence of dome, complete and incomplete septation was also looked for. Results: The mean right and left anteroposterior diameter, latero-medial diameter, area, jugular fossa width, depth in our study was 11.22, 16.52, 187.34, 6.83, 11.58 mm and 9.52, 16.02, 153.2, 5.69, 11.13 mm. Dome was present in jugular foramen in 74% on the right side and 58% on the left side. Complete septation in jugular foramen is seen in 44% on the right side and 42% on the left side. Conclusion: This study will help the neurosurgeons while doing surgery in this region.

  15. Morphometric studies with attached mouse C3H/10T 1/2 cells

    International Nuclear Information System (INIS)

    Geard, C.R.; Harding, T.

    1981-01-01

    Studies of in vitro transformation using the Syrian hamster embryo cell system and the mouse C3H/10T 1/2 cell system form an integral part of this laboratory's activities. As part of the studies with the mouse cell line we have monitored the behavior of these cells in culture in order to ascertain those variables which might influence the expression of transformation. The study of transformed cells versus normal cells could lead to insight into an earlier definition of transformation that the clonal morphological change currently in use. This present report details the changes in cellular morphology with time in culture of normal mouse C3H/10T 1/2 cells from early passages (9 to 13) and x-ray transformed cells which have been maintained in culture for three years

  16. Morphometric golgi study of some cortical locations in wag/rij and aci rat strains

    NARCIS (Netherlands)

    Karpova, A.V.; Bikbaev, A.F.; Coenen, A.M.L.; Luijtelaar, E.L.J.M. van; Luijtelaar, E.L.J.M. van; Kuznetsova, G.D.; Coenen, A.M.L.; Chepurnov, S.A.

    2004-01-01

    The present study was aimed to investigate the neuronal organization of two neocortical frontal zones using a Golgi staining technique in genetic epileptic rats, WAG/Rij's. One cortical zone was a specific part of the somatosensory cortex, which was recently proposed to contain a cortical epileptic

  17. A Cross-sectional Morphometric Study of Thyroid Glands in Cadavers

    Directory of Open Access Journals (Sweden)

    Shrish Patil

    2017-10-01

    Full Text Available Introduction: Thyroid gland is an organ with a highly variable morphology. Despite several studies having been done to assess its measurements, a consensus has not been arrived at as to what constitutes a ‘normal’ thyroid. Aim: To determine the dimensions of the normal thyroid gland obtained from cadavers of South Indian region and to derive the mean and standard deviations of the measurements of the gland in the given population, thus contributing to the existing data. We also aimed to study three common but not constant components of the thyroid gland, namely Pyramidal Lobe (PL, Tubercle of Zukerkandl (TZ and Levator Glandulae Thyroideae (LGT. Materials and Methods: The study was conducted on thyroid glands obtained from cadavers of South Indian region. Institutional ethics committee approval was obtained. Sixty thyroid glands were obtained from cadavers received for either routine dissection or autopsies. The thyroid glands were studied after adequate exposure and fixing in formalin. Dimensions were measured using Vernier calipers. Specimens with anomalies like absent isthmus etc were excluded from the study. Statistical analysis was done using the MedCalc Version 17.0 software. Results: The average dimensions of the lobes were: height 3.83 cm, width 2.62 cm, and thickness 2.69 cm. The average dimensions of the isthmus were: height 1.38 cm, width 1.36 cm and thickness 1.29 cm. The average dimensions of the pyramidal lobe were: height 2.03 cm, width at the base 1.91 cm and thickness 1.16 cm. Pyramidal lobe was present in 60% of cases. Levator glandulae thyroideae was observable in three cases (5%. Significant correlation was found between the dimensions of right and left lobes and regression equations were calculated. Conclusion: The dimensions of the thyroid gland are very variable. Knowledge of the wide ranging variations and measurements will be of help to surgeons and radiologists in correct interpretation, diagnosis and treatment of

  18. Circle of willis and its variations; morphometric study in adult human cadavers

    Directory of Open Access Journals (Sweden)

    Raghavendra, Shirol VS, Daksha Dixit, Anil Kumar Reddy Y, Desai SP

    2014-04-01

    Full Text Available Background and Objectives: Circle of Willis plays a vital role in collateral circulation and redistribution of blood to all areas of the brain. Variation in circle of Willis is known to cause grave disorders like cerebrovascular disorders, subarachnoid haemorrhage, cerebral aneurysm and schizophrenia. The objectives of the present study are to study the formation and branching pattern of circle of Willis and also to study the distribution of variations. MATERIALS & Methods: The study was conducted on 50 adult brain specimens. Each brain was removed in one piece by dissection and the circle of Willis was observed for its formation, pattern and variations. Results: Among the 50 specimens studied, 28 cases (56% had a normal pattern of circle of Willis and variations were observed in the remaining 22 cases (44%. More number of variations was observed on the right side than on the left side. The most common variation observed was hypoplastic posterior communicating artery (7 cases, 31.8%. Posterior communicating artery was found to be the most variable vessel while middle cerebral artery was the least variable vessel. Interpretation and Conclusion: The results with respect to the circle of Willis and all its component arteries were consistent with the results in the available literature. The only exception was the increased incidence of absence of both the anterior and posterior communicating arteries. This finding is of clinical significance to neurologists and neurosurgeons in this geographical location of north Karnataka. A higher incidence of variations in the communicating arteries is likely to manifest as a higher incidence in disorders like migraine, schizophrenia and cerebrovascular disorders due to compromised collateral circulation and poor redistribution of blood.

  19. Variability of morphometric parameters of human trabecular tissue from coxo-arthritis and osteoporotic samples

    Directory of Open Access Journals (Sweden)

    Franco Marinozzi

    2012-01-01

    Full Text Available Morphometric and architectural bone parameters change in diseases such as osteoarthritis and osteoporosis. The mechanical strength of bone is primarily influenced by bone quantity and quality. Bone quality is defined by parameters such as trabecular thickness, trabecular separation, trabecular density and degree of anisotropy that describe the micro-architectural structure of bone. Recently, many studies have validated microtomography as a valuable investigative technique to assess bone morphometry, thanks to micro-CT non-destructive, non-invasive and reliability features, in comparison to traditional techniques such as histology. The aim of this study is the analysis by micro-computed tomography of six specimens, extracted from patients affected by osteoarthritis and osteoporosis, in order to observe the tridimensional structure and calculate several morphometric parameters.

  20. Comparação morfométrica da orelha interna entre ovinos e humanos através da tomografia computadorizada CT-Scan sheep and human inner ear morphometric comparison

    Directory of Open Access Journals (Sweden)

    Valter Ayres Seibel

    2006-06-01

    Full Text Available INTRODUÇÃO: trabalhos sobre o uso de ovelhas em cirurgias experimentais e treinamento em cirurgia otológica são raros. Este estudo pretende contribuir para ampliar o conhecimento nessa área. OBJETIVO: Estudar a orelha interna da ovelha por meio de tomografia computadorizada e cortes sucessivos com o intuito de apresentar dados morfométricos mais precisos relacionados à comparação entre a orelha de ovelhas e a de humanos. MATERIAL E MÉTODO: Foi realizado um estudo descritivo sem seguimento no qual foram comparadas as estruturas da orelha interna da ovelha com as dos humanos. As medidas foram obtidas através de tomografias computadorizadas e avaliadas por meio de um programa de análise de imagens médicas (Osíris 4.16. RESULTADOS: O estudo morfológico da orelha da ovelha, em média, e da orelha humana, em média, revelaram grande similaridade de anatomia. A maior parte das estruturas (10 de 15 preservou a relação proposta de 2/3 da dimensão humana em relação à dimensão ovina. CONCLUSÃO: Os achados contribuem para uso da orelha da ovelha como modelo em cirurgia experimental e treinamento em cirurgia otológica.INTRODUCTION: Studies about the use of sheep in surgical training and experimental otologic surgery are rare. This study intends to contribute to the knowledge on this field. AIM: To study sheep inner ear structures using computerized tomography and serial cross-sections to collect more accurate morphometric data to compare sheep and human ears. MATERIAL AND METHODS: This descriptive study compared the inner structures of sheep and human ears. Measurements were made using computerized tomography, and they were stored in a DICOM compact disc for later analysis and manipulation, with a program used for medical image analysis (Osíris 4.16. RESULTS: Mean measures for sheep and human ears were found to be similar in this morphological study. Most structures (10 out of 15 maintained the 2/3 ratio of sheep to human ear

  1. Study of needle morphometric indices in Scots pine in the remote period after the Chernobyl accident

    International Nuclear Information System (INIS)

    Makarenko, E.S.; Geras'kin, S.A.; Oudalova, A.A.

    2016-01-01

    Biological effects in Scots pine populations experiencing chronic radiation exposure at doses up to 130 mGy per year as a result of the Chernobyl accident were studied in 2011 and 2013, using needle indices as endpoints. No relationships between the length, the mass of needles and the asymmetry in weight of paired needles and radiation exposure were revealed. The frequency of necrotic needles increases with the level of radiation exposure; however, the significance of these effects in different years was different. The index of fluctuating asymmetry in needle length significantly increases at annual doses of 90 and 130 mGy and correlates with the absorbed dose as well as 137 Cs and 90 Sr radionuclide activities in soils and cones at the study sites. The findings obtained are consistent with an international recommendation to consider radiation exposure of 100 mGy.y -1 as a margin for biota safety in chronic irradiation. (authors)

  2. Morphometric study of tensor of vastus intermedius in South Indian population.

    Science.gov (United States)

    Veeramani, Raveendranath; Gnanasekaran, Dhivyalakshmi

    2017-03-01

    Tensor of vastus intermedius is a newly discovered muscle located between vastus lateralis and vastus intermedius. The purpose of this study was to investigate the detailed morphology of tensor of vastus intermedius, specifically to provide data pertaining to the attachments, innervations, variation in the types and its morphometry in South Indian population. The tensor of vastus intermedius was studied in thirty six cadaveric lower limbs using macrodissection techniques. The origin of the muscle was from upper part of intertrochanteric line and anterior part of greater trochanter of femur inserted to medial aspect of upper border of patella. The muscle was classified into four types based on the origin and also the aponeurosis course with independent type (type 1) being common. The mean and standard deviation of the length of tensor of vastus intermedius and aponeurosis were 145.40±37.55 mm and 193.55±42.32 mm, respectively. The results of the study suggest that tensor of vastus intermedius is variable and the information provided regarding the attachments, types and quantitative data will contribute to the existing knowledge of the muscle.

  3. Extended Endoscopic Endonasal Approaches for Cerebral Aneurysms: Anatomical, Virtual Reality and Morphometric Study

    Directory of Open Access Journals (Sweden)

    Alberto Di Somma

    2014-01-01

    Full Text Available Introduction. The purpose of the present contribution is to perform a detailed anatomic and virtual reality three-dimensional stereoscopic study in order to test the effectiveness of the extended endoscopic endonasal approaches for selected anterior and posterior circulation aneurysms. Methods. The study was divided in two main steps: (1 simulation step, using a dedicated Virtual Reality System (Dextroscope, Volume Interactions; (2 dissection step, in which the feasibility to reach specific vascular territory via the nose was verified in the anatomical laboratory. Results. Good visualization and proximal and distal vascular control of the main midline anterior and posterior circulation territory were achieved during the simulation step as well as in the dissection step (anterior communicating complex, internal carotid, ophthalmic, superior hypophyseal, posterior cerebral and posterior communicating, basilar, superior cerebellar, anterior inferior cerebellar, vertebral, and posterior inferior cerebellar arteries. Conclusion. The present contribution is intended as strictly anatomic study in which we highlighted some specific anterior and posterior circulation aneurysms that can be reached via the nose. For clinical applications of these approaches, some relevant complications, mainly related to the endonasal route, such as proximal and distal vascular control, major arterial bleeding, postoperative cerebrospinal fluid leak, and olfactory disturbances must be considered.

  4. The neuroanatomical basis of panic disorder and social phobia in schizophrenia: a voxel based morphometric study.

    Science.gov (United States)

    Picado, Marisol; Carmona, Susanna; Hoekzema, Elseline; Pailhez, Guillem; Bergé, Daniel; Mané, Anna; Fauquet, Jordi; Hilferty, Joseph; Moreno, Ana; Cortizo, Romina; Vilarroya, Oscar; Bulbena, Antoni

    2015-01-01

    It is known that there is a high prevalence of certain anxiety disorders among schizophrenic patients, especially panic disorder and social phobia. However, the neural underpinnings of the comorbidity of such anxiety disorders and schizophrenia remain unclear. Our study aims to determine the neuroanatomical basis of the co-occurrence of schizophrenia with panic disorder and social phobia. Voxel-based morphometry was used in order to examine brain structure and to measure between-group differences, comparing magnetic resonance images of 20 anxious patients, 20 schizophrenic patients, 20 schizophrenic patients with comorbid anxiety, and 20 healthy control subjects. Compared to the schizophrenic patients, we observed smaller grey-matter volume (GMV) decreases in the dorsolateral prefrontal cortex and precentral gyrus in the schizophrenic-anxiety group. Additionally, the schizophrenic group showed significantly reduced GMV in the dorsolateral prefrontal cortex, precentral gyrus, orbitofrontal cortex, temporal gyrus and angular/inferior parietal gyrus when compared to the control group. Our findings suggest that the comorbidity of schizophrenia with panic disorder and social phobia might be characterized by specific neuroanatomical and clinical alterations that may be related to maladaptive emotion regulation related to anxiety. Even thought our findings need to be replicated, our study suggests that the identification of neural abnormalities involved in anxiety, schizophrenia and schizophrenia-anxiety may lead to an improved diagnosis and management of these conditions.

  5. Gross morphometric study of the eyeball and tongue of the Nigerian local dog.

    Science.gov (United States)

    Igado, Olumayowa Olawumi

    2011-01-01

    This study investigates the morphometry of two sense organs, the eyeball and tongue, of the Nigerian local dog (11 males, 14 females), all aged 2 years and above. The samples were grouped according to gender and weight (up to 12 kg or above that weight). The average values obtained for the weights of the left and right eyeballs and the tongue were 3.77 +/- 0.51 g, 3.68 +/- 0.74 g and 2.96 +/- 0.38 g respectively, while the length of the tongue, its thickness and width at the root and apex were 14.20 +/- 2.29 cm, 0.87 +/- 0.30 cm, and 0.21 +/- 0.05 cm respectively. The circumferences of the eyeballs (antero-posterior, mediolateral and peri-orbital) were all found to be higher in females, except the antero-posterior circumference of left eye, in spite of heavier eyeballs in males. Also, the females showed a wider rima oris and higher values for most of the tongue measurements. A positive correlation existed between the weight of the animal and that of the head and tongue, while a negative correlation was observed between the body weight and the weight of the eyeballs. This report highlights the presence of sexual dimorphism and mild lateral asymmetry in this rarely reported breed of dog. The data obtained from this study may find application in feeding physiology, ophthalmic clinical manipulations and comparative anatomy.

  6. Distal Insertional Footprint of the Brachialis Muscle: 3D Morphometric Study

    Directory of Open Access Journals (Sweden)

    Srinath Kamineni

    2015-01-01

    Full Text Available Objective. The purpose of this study is to describe the three-dimensional morphometry of the brachialis muscle at its distal attachment to the ulna. Methods. Fifty cadaveric elbows were dissected and the brachialis distal insertion was isolated on the ulna bone and probed with a three-dimensional digitizer, to create a three-dimensional model of the footprint. Measurements and analysis of each footprint shape were recorded and compared based on gender and size. Results. There was significant gender difference in the surface length (P= 0.002 and projected length (P= 0.001 of the brachialis footprint. The shapes of the footprint also differed among the specimens. Conclusion. The shape of the brachialis muscle insertion differed among all the specimens without significant variation in gender or sides. There was also a significant difference in muscle length between males and females with little difference in the width and surface area. Significance. The information obtained from this study is important for kinematic understanding and surgical procedures around the elbow joint as well as the understanding of the natural age related anatomy of the brachialis footprint morphology.

  7. Identification of components of fibroadenoma in cytology preparations using texture analysis: a morphometric study.

    Science.gov (United States)

    Singh, S; Gupta, R

    2012-06-01

    To evaluate the utility of image analysis using textural parameters obtained from a co-occurrence matrix in differentiating the three components of fibroadenoma of the breast, in fine needle aspirate smears. Sixty cases of histologically proven fibroadenoma were included in this study. Of these, 40 cases were used as a training set and 20 cases were taken as a test set for the discriminant analysis. Digital images were acquired from cytological preparations of all the cases and three components of fibroadenoma (namely, monolayered cell clusters, stromal fragments and background with bare nuclei) were selected for image analysis. A co-occurrence matrix was generated and a texture parameter vector (sum mean, energy, entropy, contrast, cluster tendency and homogeneity) was calculated for each pixel. The percentage of pixels correctly classified to a component of fibroadenoma on discriminant analysis was noted. The textural parameters, when considered in isolation, showed considerable overlap in their values of the three cytological components of fibroadenoma. However, the stepwise discriminant analysis revealed that all six textural parameters contributed significantly to the discriminant functions. Discriminant analysis using all the six parameters showed that the numbers of pixels correctly classified in training and tests sets were 96.7% and 93.0%, respectively. Textural analysis using a co-occurrence matrix appears to be useful in differentiating the three cytological components of fibroadenoma. These results could further be utilized in developing algorithms for image segmentation and automated diagnosis, but need to be confirmed in further studies. © 2011 Blackwell Publishing Ltd.

  8. Radio-morphometric Analysis of Sella Turcica in the South Indian Population: A Digital Cephalometric Study

    Directory of Open Access Journals (Sweden)

    Ch. Sai Kiran

    2017-06-01

    Results: A higher percentage of both males (70.0% and females (67.7% were presented with normal sella. The second best sella presentation was the shallow sella in males (16.2%. The mean antero-posterior diameter was significantly higher in females (12.25 mm than males (11.74 mm. The mean depth of sella turcica was greater in females (8.08 mm than males (7.68mm. Discriminant function analysis was done with gender as a grouping variable and antero-posterior dimensions and sella depth as independent variables. The formula obtained was D = 0.452 (x +0.295(y-7.753. (Where “D” is the discriminant score “x” is antero-posterior diameter of sella “y” is sella depth.The present study revealed an overall accuracy rate of58.1% in identifying correct gender using sella measurements. Conclusion: The present study was the first of its kind in the South Indian population and has presented results that justify the use of sella turcica for sex determination.

  9. Morphometric changes in the spinal cord during prenatal life: a stereological study in sheep.

    Science.gov (United States)

    Sadeghinezhad, Javad; Zadsar, Narges; Hasanzadeh, Beal

    2018-03-01

    This study describes the volumetric changes in the spinal cord during prenatal life in sheep using quantitative stereological methods. Twenty healthy sheep fetuses were included in the present study, divided into four groups representing 9-11, 12-14, 15-17, and 18-20 weeks of gestation. In each group, the spinal cord was dissected out and sampled according to the unbiased systematic random sampling method then used for stereological estimations. The total volume of spinal cord, volume of gray matter (GM), volume of white matter (WM), ratio of GM volume to WM volume, and volume of central canal (CC) were estimated in the whole spinal cord and its various regions using Cavalieri's principle. The total volume of the spinal cord increased 8 times from week 9 to week 20. The cervical region showed the greatest (9.7 times) and the sacral region the least (6.3 times) volumetric change. The CC volume of the whole spinal cord increased 5.8 times from week 9 to week 20. The cervical region developed faster (8.2 times) and the thoracic region slower (4.4 times) than the total spinal cord. During development, the volume ratio of GM to WM decreased from lower toward upper regions. The greatest volume changes occurred mostly in weeks 9-11 and 12-14. The cervical region showed the greatest volume changes in comparison with other regions of the spinal cord.

  10. A Comparative Morphometrical Study of the Pecten Oculi in Different Avian Species

    Directory of Open Access Journals (Sweden)

    Mustafa Orhun Dayan

    2013-01-01

    Full Text Available In this study was investigated the structure of pecten oculi in the ostrich, duck, pigeon, turkey, and starling. The pecten oculi of the ostrich was vaned type and made up primary, secondary, and few tertiary lamellae. However, duck, pigeon, turkey and starling had a pleated-type pecten oculi which displayed folded structure. The numbers of pleats of the pectens were 12, 13-14, 21-22, and 17 in duck, pigeon, turkey, and starling, respectively. Light microscopic investigation demonstrated that pecten oculi is basically composed of numerous capillaries, large blood vessels, and pigment cells in all investigating avian species. Capillaries were 20.23, 14.34, 11.78, 12.58, and 12.78 μm in diameter in ostrich, duck, pigeon, turkey, and starling, respectively. The capillaries are surrounded by thick basal membrane, and pigmented cells were observed around the capillaries.

  11. Anatomical variations and morphometric study of the optic strut and the anterior clinoid process

    Directory of Open Access Journals (Sweden)

    Eldan Kapur

    2012-05-01

    Full Text Available The optic strut and the anterior clinoid process represent bony structures that are closely related to anatomically and clinically significant elements such as the cavernous sinus, the internal carotid artery, the optic nerve and the pituitary gland. The objective of our study was to quantify dimensions of the optic strut and anterior clinoid process, and to determine variations in positions and forms of these structures. A descriptive anatomical study was performed on 200 dry human skulls. We analyzed dimensions and variations in position of the optic strut, dimensions of the anterior clinoid process as well as the incidence and forms of the caroticoclinoid foramen. The average thickness of the optic strut on skulls belonging to males was 3 mm and 2.8 mm on those belonging to females. The optic strut was most commonly attached to the anterior two fifths on the lower side of the anterior clinoid process. On the male skulls the average width of the anterior clinoid process was 9.4 mm (right and 9.1 mm (left. Its length was 9.9 and 9.3 mm. On female skulls the average width of the process was 8.7 mm (right and 8.3 mm (left, while the length measured 9.3 mm on the right and 8.9 mm on the opposite side. In our sample, a complete caroticoclinoid foramen appeared in 4.25%, a contact form in 2.75%. At last, an incomplete form of the foramen was observed in 9.75%. The anatomic variations of the investigated structures must be considered during the approaches to the cavernous sinus and neurovascular elements of the sellar region.

  12. A Voxel-Based Morphometric MRI Study in Young Adults with Borderline Personality Disorder.

    Directory of Open Access Journals (Sweden)

    Xinhu Jin

    Full Text Available Increasing evidence has documented subtle changes in brain morphology and function in patients with borderline personality disorder (BPD. However, results of magnetic resonance imaging volumetry in patients with BPD are inconsistent. In addition, few researchers using voxel-based morphometry (VBM have focused on attachment and childhood trauma in BPD. This preliminary study was performed to investigate structural brain changes and their relationships to attachment and childhood trauma in a homogenous sample of young adults with BPD.We examined 34 young adults with BPD and 34 healthy controls (HCs to assess regionally specific differences in gray matter volume (GMV and gray matter concentration (GMC. Multiple regressions between brain volumes measured by VBM and attachment style questionnaire (ASQ and childhood trauma questionnaire (CTQ scores were performed.Compared with HCs, subjects with BPD showed significant bilateral increases in GMV in the middle cingulate cortex (MCC/posterior cingulate cortex (PCC/precuneus. GMC did not differ significantly between groups. In multiple regression models, ASQ insecure attachment scores were correlated negatively with GMV in the precuneus/MCC and middle occipital gyrus in HCs, HCs with more severe insecure attachment showed smaller volumes in precuneus/MCC and middle occipital gyrus, whereas no negative correlations between insecure attachment and GMV in any region were found in BPD group. In addition, CTQ total scores were not correlated with GMV in any region in the two groups respectively.Our findings fit with those of previous reports of larger precuneus GMV in patients with BPD, and suggest that GMV in the precuneus/MCC and middle occipital gyrus is associated inversely with insecure attachment style in HCs. Our finding of increased GMV in the MCC and PCC in patients with BPD compared with HCs has not been reported in previous VBM studies.

  13. A morphometric anatomical and comparative study of the foramen magnum region in a Greek population.

    Science.gov (United States)

    Natsis, K; Piagkou, M; Skotsimara, G; Piagkos, G; Skandalakis, P

    2013-12-01

    The foramen magnum (FM), a complex area in craniocervical surgery, poses a challenge for neurosurgeons. The knowledge of the detailed anatomy of the FM, occipital condyles (OC) and variations of the region is crucial for the safety of vital structures. This study focuses on the FM and OC morphometry, highlights anatomical variability and investigates correlations between the parameters studied. One hundred and forty-three Greek adult dry skulls were examined using a digital sliding calliper (accuracy, 0.01 mm). Mean FM width and length were found 30.31 ± 2.79 and 35.53 ± 3.06 mm, respectively. The commonest FM shape was two semicircles (25.9 %), whereas the most unusual was irregular (0.7 %). The OC minimum width, maximum width and length were 5.71 ± 1.61, 13.09 ± 1.99 and 25.60 ± 2.91 mm on the right, and 6.25 ± 1.76, 13.01 ± 1.98 and 25.60 ± 2.70 mm on the left side. The commonest OC shape was S-like and the most unusual was ring, bilaterally. The mean anterior and posterior intercondylar distances were 19.30 ± 3.25 and 51.61 ± 5.01 mm, respectively. The OC protruded into the FM in 86.7 % of the skulls. Variations such as a third OC existed in 5.6 % and basilar processes in 2.8 %. Posterior condylar foramina were present in 75.5 %. The gender was correlated with FM width and length, OC length, bilaterally, anterior intercondylar distance (AID) and posterior intercondylar distance (PID). The OC protrusion and existence of posterior condylar foramina were correlated. Bilateral asymmetry for OC shape was statistically significant. Our results provide useful information that will enable effective and reliable surgical intervention in the FM region with the maximum safety and widest possible exposure.

  14. Comparative study of morphometric proportions among Campolina´s stallions and gelded ones

    Directory of Open Access Journals (Sweden)

    Jorge Eduardo Cavalcante Lucena

    2015-02-01

    Full Text Available In the equine species, the surface characteristics, present a close relationship with its functional classification. The scientific use of linear measurements can contribute decisively in the selective process of many breeds, by identifying the higher morphologically individuals and excluding from reproduction those that are not closed to desirable. The present study objected to evaluate and compare, the linear measures from stallions and gelded horses registered in ABCCCampolina’s CP6 and CP8 books, and to determinate the existing correlations. In order to reach so, 15 linear measures from 4.837 stallions and 1.371 gelded were evaluated from descriptive statistic, Pearson’s correlation and analysis of variance. Generally, higher values of correlations were observed for stallions than to gelded ones. To stallions, most of the measures were significantly influenced (P<0,01 by the year of birth, state of birth and coat color, while to gelded ones the coat color showed lower influence (P<0,01 upon the measures. It’s important to notice that castration did not committed the animal’s final growth, however the breeders non sense the lack of appropriated criteria during the selection process and personal preferences can contribute towards stablishing breed characters rather than functionals. This can be highlighted by the fact that Campolina’s gelded horses showed, in average, better proportioned than stallions.

  15. Improved survival of macroencapsulated islets of Langerhans by preimplantation of the immunoisolating device: a morphometric study.

    Science.gov (United States)

    Rafael, E; Wu, G S; Hultenby, K; Tibell, A; Wernerson, A

    2003-01-01

    Encapsulation of cells in a semipermeable membrane may in the future provide an opportunity to treat a variety of endocrine and neurological disorders, without the need for lifelong immunosuppression. The physiological conditions in the device are crucial factors for graft survival. Previously, we have shown that the exchange across the immunoisolating membrane and the microcirculation around the TheraCyte device increase around 3 months after implantation. The aim of this study was to determine whether preimplantation of the TheraCyte device would improve the survival of a later transplanted islet graft. A TheraCyte device was implanted SC on one side of the back of a nondiabetic SD rat. After 3 months, 1500 islets isolated from SD rats were transplanted via the device port. At the same time, another device, loaded with the same number of islets, was implanted on the other side of the back. Both devices were explanted 2 weeks after islet transplantation (i.e., 3.5 months and 0.5 month after device implantation, respectively). Six pairs of devices were evaluated by morphometery. The volume densities of viable islets were 0.22 +/- 0.04 in the preimplanted device vs. 0.06 +/- 0.03 in the nonpreimplanted one (p TheraCyte device seems to improve the survival of an encapsulated islet graft and reduce fibroblast outgrowth in the device.

  16. Morphometric study of the lumbar spinal canal in the Korean population.

    Science.gov (United States)

    Lee, H M; Kim, N H; Kim, H J; Chung, I H

    1995-08-01

    The anatomic dimensions of the vertebral body and spinal canal of the lumbar spine were analyzed in Koreans. To determine the normal dimension of the lumbar spinal canal in Koreans, to determine whether there are any racial differences in the morphometry of the lumbar spinal canal, and to provide criteria for diagnosing spinal stenosis in the Far Eastern Asian. Some radiologic and anatomic studies have been conducted regarding the size of the lumbar spinal canal of whites and blacks in western and African countries. One-thousand-eight-hundred measurements were performed on the transverse and sagittal diameters of vertebral bodies and spinal canals using complete sets of 90 lumbar vertebrae. The mean mid-sagittal diameter of the lumbar spinal canal in the Korean population was less than that measured in white and African populations, but there was no significant differences between the Korean, white, and African populations regarding the transverse diameter of the lumbar spinal canal. The mid-sagittal diameter of the lumbar spinal canal is narrowest in the Far Eastern Asian population; the radiologic criteria of spinal stenosis should be reconsidered for these people.

  17. Uncovering the social deficits in the autistic brain.A Source-Based Morphometric study

    Directory of Open Access Journals (Sweden)

    Alessandro Grecucci

    2016-08-01

    Full Text Available Autism is a neurodevelopmental disorder that mainly affects social interaction and communication. Evidence from behavioral and functional MRI studies supports the hypothesis that dysfunctional mechanisms involving social brain structures play a major role in autistic symptomatology. However, the investigation of anatomical abnormalities in the brain of people with autism has led to inconsistent results. We investigated whether specific brain regions, known to display functional abnormalities in autism, may exhibit mutual and peculiar patterns of covariance in their grey-matter concentrations. We analyzed structural MRI images of 32 young men affected by autistic disorder (AD and 50 healthy controls. Controls were matched for sex, age, handedness. IQ scores were also monitored to avoid confounding. A multivariate Source-Based Morphometry (SBM was applied for the first time on AD and controls to detect maximally independent networks of gray matter. Group comparison revealed a gray-matter source that showed differences in AD compared to controls. This network includes broad temporal regions involved in social cognition and high-level visual processing, but also motor and executive areas of the frontal lobe. Notably, we found that gray matter differences, as reflected by SBM, significantly correlated with social and behavioral deficits displayed by AD individuals and encoded via the Autism Diagnostic Observation Schedule scores. These findings provide support for current hypotheses about the neural basis of atypical social and mental states information processing in autism.

  18. Structural covariance and cortical reorganisation in schizophrenia: a MRI-based morphometric study.

    Science.gov (United States)

    Palaniyappan, Lena; Hodgson, Olha; Balain, Vijender; Iwabuchi, Sarina; Gowland, Penny; Liddle, Peter

    2018-05-06

    In patients with schizophrenia, distributed abnormalities are observed in grey matter volume. A recent hypothesis posits that these distributed changes are indicative of a plastic reorganisation process occurring in response to a functional defect in neuronal information transmission. We investigated the structural covariance across various brain regions in early-stage schizophrenia to determine if indeed the observed patterns of volumetric loss conform to a coordinated pattern of structural reorganisation. Structural magnetic resonance imaging scans were obtained from 40 healthy adults and 41 age, gender and parental socioeconomic status matched patients with schizophrenia. Volumes of grey matter tissue were estimated at the regional level across 90 atlas-based parcellations. Group-level structural covariance was studied using a graph theoretical framework. Patients had distributed reduction in grey matter volume, with high degree of localised covariance (clustering) compared with controls. Patients with schizophrenia had reduced centrality of anterior cingulate and insula but increased centrality of the fusiform cortex, compared with controls. Simulating targeted removal of highly central nodes resulted in significant loss of the overall covariance patterns in patients compared with controls. Regional volumetric deficits in schizophrenia are not a result of random, mutually independent processes. Our observations support the occurrence of a spatially interconnected reorganisation with the systematic de-escalation of conventional 'hub' regions. This raises the question of whether the morphological architecture in schizophrenia is primed for compensatory functions, albeit with a high risk of inefficiency.

  19. Precuneus atrophy in early-onset Alzheimer's disease: a morphometric structural MRI study

    International Nuclear Information System (INIS)

    Karas, Giorgos; Scheltens, Philip; Jones, Bethany; Rombouts, Serge; Schijndel, Ronald van; Klein, Martin; Flier, Wiesje van der; Vrenken, Hugo; Barkhof, Frederik

    2007-01-01

    Alzheimer's disease (AD) usually first presents in elderly patients, but may also develop at an earlier age. Patients with an early age at onset tend to present with complaints other than memory impairment, such as visuospatial problems or apraxia, which may reflect a different distribution of cortical involvement. In this study we set out to investigate whether age at onset in patients with AD determines the pattern of atrophy on cerebral MRI scans. We examined 55 patients with AD over a wide age range and analyzed their 3-D T1-weighted structural MRI scans in standard space using voxel-based morphometry (VBM). Regression analysis was performed to estimate loss of grey matter as a function of age, corrected for mini-mental state examination (MMSE) scores and sex. The VBM analyses identified multiple areas (including the temporal and parietal lobes), showing more atrophy with advancing age. By contrast, a younger age at onset was found to be associated with lower grey matter density in the precuneus. Regionalized volumetric analysis of this region confirmed the existence of disproportionate atrophy in the precuneus in patients with early-onset AD. Application of a multivariate model with precuneus grey matter density as input, showed that precuneal and hippocampal atrophy are independent from each other. Additionally, we found that a smaller precuneus is associated with impaired visuospatial functioning. Our findings support the notion that age at onset modulates the distribution of cortical involvement, and that disproportionate precuneus atrophy is more prominent in patients with a younger age of onset. (orig.)

  20. Development of the human lateral geniculate nucleus: A morphometric and computerized 3D-reconstruction study.

    Science.gov (United States)

    Yamaguchi, Katsuyuki

    2018-04-04

    The lateral geniculate nucleus (LGN) is the major relay center of the visual pathway in humans. There are few quantitative data on the morphology of LGN in prenatal infants. In this study, using serial brain sections, the author investigated the morphology of this nucleus during the second half of fetal period. Eleven human brains were obtained at routine autopsy from preterm infants aged 20-39 postmenstrual weeks. After fixation, the brain was embedded en bloc in celloidin and cut serially at 30 μm in the horizontal plane. The sections were stained at regular intervals using the Klüver-Barrera method. At 20-21 weeks, the long axis of LGN declined obliquely from the vertical to horizontal plane, while a deep groove was noted on the ventro-lateral surface of the superior half. At this time, an arcuate cell-sparse zone appeared in the dorso-medial region, indicating the beginning of lamination. From 25 weeks onwards, the magnocellular and parvocellular layers were distinguishable, and the characteristic six-layered structure was recognized. The magnocellular layer covered most of the dorsal surface, and parts of the medial, lateral, and inferior surfaces but not the ventral and superior surfaces. Nuclear volume increased exponentially with age during 20-39 weeks, while the mean neuronal profile area increased linearly during 25-39 weeks. Human LGN develops a deep groove on the ventro-lateral surface at around mid-gestation, when the initial lamination is recognized in the prospective magnocellular layer. Thereafter, the nuclear volume increases with age in an exponential function. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. The morphometric study of the pons and cerebellum in Korean using MRI

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Kim, Dong Ik; Yun, Mi Jin; Chung, In Hyuk; Cho, Young Kook

    1995-01-01

    To evaluate the size of normal pons and cerebellum in vivo and the change in size according to age, and to compare those with measurement of the diseased pons and cerebellum. 121 normal adults (M:F=54:67), 5 patients with OPCD and 19 patients with Wallerian degeneration were studied. The normal group was divided into 5 subgroups according to the age (ranged from 20 to 72 years). 1.5T GE Signa MR unit was used. On axial plane, the AP(A) and transverse(B) diameters of the pons, the size of the middle cerebellar peduncle(C), and transverse diameter of the posterior fossa(D) and the cerebellum(E) were measured. On midsagittal plane, the longitudinal(F) and AP(G) diameters of the basis pontis were measured. The ratios of E/D and F/G were calculated. The student t test was used for statistical analysis. C, E and F/G were 15.5 mm ± 1.3, 99.8 mm ± 4.3 and 1.63 ± 10, respectively. F/G, H/I, and H/J were larger in male (ρ < .01). All data of the pons showed no statistically significant differences among age groups. E of the seventh decades was shorter than that of the third decades (ρ < .05). C(12.7 mm ± 1.4) in OPCD and F/G(1.81 ± .10) in Wallerian degeneration (± < .01) showed the most significant differences when they were compared to the normal. Although the cerebellum decreased in size with age, the pons maintained its size up to eighth decades. The measurement of middle cerebellar peduncle on axial plane (C) and the ratio of basis pontis on midsagittal plane (F/G) were important in the evaluation of OPCD and Wallerian degeneration, respectively

  2. Preliminary morphological and morphometric study of rat cerebellum following sodium arsenite exposure during rapid brain growth (RBG) period

    International Nuclear Information System (INIS)

    Dhar, Pushpa; Mohari, Nivedita; Mehra, Raj D.

    2007-01-01

    The effects of arsenic exposure during rapid brain growth (RBG) period were studied in rat brains with emphasis on the Purkinje cells of the cerebellum. The RBG period in rats extends from postnatal day 4 (PND 4) to postnatal day 10 (PND 10) and is reported to be highly vulnerable to environmental insults. Mother reared Wistar rat pups were administered intraperitoneal injections (i.p.) of sodium arsenite (aqueous solution) in doses of 1.0, 1.5 and 2.0 mg/kg body weight (bw) to groups II, III and IV (n = 6 animals/group) from PND 4 to 10 (sub acute). Control animals (group I) received distilled water by the same route. On PND 11, the animals were perfusion fixed with 4% paraformaldehyde in 0.1 M phosphate buffer (PB) with pH 7.4. The cerebellum obtained from these animals was post-fixed and processed for paraffin embedding. Besides studying the morphological characteristics of Purkinje cells in cresyl violet (CV) stained paraffin sections (10 μm), morphometric analysis of Purkinje cells was carried out using Image Analysis System (Image Proplus software version 4.5) attached to Nikon Microphot-FX microscope. The results showed that on PND 11, the Purkinje cells were arranged in multiple layers extending from Purkinje cell layer (PL) to outer part of granule cell layer (GL) in experimental animals (contrary to monolayer arrangement within PL in control animals). Also, delayed maturation (well defined apical cytoplasmic cones and intense basal basophilia) was evident in Purkinje cells of experimental animals on PND 11. The mean Purkinje cell nuclear area was significantly increased in the arsenic treated animals compared to the control animals. The observations of the present study (faulty migration, delayed maturation and alteration in nuclear area measurements of Purkinje cells subsequent to arsenic exposure) thus provided the morphological evidence of structural alterations subsequent to arsenite induced developmental neurotoxicity which could be presumed to be

  3. 1 Morphometric studies

    African Journals Online (AJOL)

    Administrator

    From the numerical character analysis, morphological characters like peduncle length ... diameter, filament length, style length, plant height, petiole diameter, sepal length and petal length were identified ..... variation and speciation in plants.

  4. Nerve growth factor induced changes in the Golgi apparatus of PC-12 rat pheochromocytoma cells as studied by ligand endocytosis, cytochemical and morphometric methods.

    Science.gov (United States)

    Hickey, W F; Stieber, A; Hogue-Angeletti, R; Gonatas, J; GOnatas, N K

    1983-10-01

    Cells of the PC-12 rat pheochromocytoma cell line respond to nerve growth factor (NGF) by sprouting neurites and biochemically differentiating into sympathetic ganglion-like cells. NGF-stimulated ('differentiated') and unstimulated ('undifferentiated') cells were studied by cytochemical techniques for the localization of the enzymes acid phosphatase (ACPase) and thiamine pyrophosphatase (TPPase), and by a morphometric analysis of the distribution of endocytosed wheat-germ agglutinin labelled with horseradish peroxidase (WGA-HRP). Both cytochemical stains showed the enzymes to be distributed in lysosomes and certain cisternae of the Golgi apparatus in both NGF stimulated and unstimulated cells. ACPase was not confined to GERL (Golgi-endoplasmic reticulum-lysosome) as in certain other cells. The morphometric studies demonstrated that the reaction product of the internalized WGA-HRP occupied 4.7% of the cytoplasmic area in unstimulated cells and 4.5% in NGF-stimulated ones. Despite this similarity, the distribution of the WGA-HRP among the studied intracellular compartments in these two cell groups varied. In the NGF-stimulated cells 3.3% of the WGA-HRP reaction product was found in the innermost Golgi cisterna(e) while in unstimulated cells only 0.3% was seen in this compartment. Similarly, 4.3% of the WGA-HRP stain was found in small vesicles at the 'trans' aspect of the Golgi apparatus in stimulated cells, when only 0.3% of the stain occupied this compartment in 'undifferentiated' cells. The morphometric analysis also revealed that when the PC-12 cells were stimulated with NGF, the Golgi apparatus increased in area by approximately 70%. These findings are consistent with the hypothesis that NGF induced differentiation of PC-12 cells is coupled with enhanced endocytosis of WGA and probably of its 'receptor' to the innermost Golgi cisterna(e) and the closely associated vesicles.

  5. Neck after total laryngectomy: CT study

    International Nuclear Information System (INIS)

    DiSantis, D.J.; Balfe, D.M.; Hayden, R.E.; Sagel, S.S.; Sessions, D.; Lee, J.K.T.

    1984-01-01

    Computed tomographic scans in 23 patients who had undergone total laryngectomy were analyzed retrospectively to determine normal postoperative appearance and to evaluate the role of CT in assessing recurrent neoplasm. Nine patients without clinical evidence of recurrence illustrated the normal postoperative changes: a round or ovoid neopharynx connecting the base of the tongue with the cervical esophagus and intact fat planes surrounding the neopharynx, neurovascular bundles, and sternocleidomastoid muscles. In the 12 patients with recurrent neoplasm, the CT manifestations included masses involving the internal jugular lymph node chain, tracheostomy site, or paratracheal region. CT supplemented physical examination and indirect mirror examination, providing data regarding presence and extent of recurrent tumor and aiding in planning the mode and scope of therapy

  6. The experimental study of sinal wall thickening on CT

    International Nuclear Information System (INIS)

    Kase, Yasuhiro; Iinuma, Tositaka; Oyama, Kazuyuki.

    1988-01-01

    In our previous report, we investigated several factors which cause apparent thickening of the walls of maxillary sinus. We confirmed, however, that the major factor for the sinal wall thickening is the artifact of CT. In present study, we report the results obtained by phantom models of isolated maxillary bone and egg shell. As the substance corresponding to the soft tissue density, solutions of CaCl 2 in various concentrations were used. In the maxillary bone studies, the thickness of the anterior sinus wall by CT was larger than the actual value even though only the air was contained. When solutions of CaCl 2 were contained and in touch with the anterior wall, the thickness by CT was larger than that of containing air. In the egg shell studies, the increase in thickness by CT correlated to the increase in percentage of solutions. The above results indicate that the apparent increased thickness of the sinal walls by CT is largely the artifact by CT and is dependent upon the soft tissue density or CT value (X-ray attenuation coefficient) of substances in touch with the sinal walls. In CT images obtained by clinical cases, the increased thickness of the sinal walls, in sinuses filled with soft tissue density, is more apparent than real. (author)

  7. Morphometric Analysis of Didessa River Catchment in Blue Nile ...

    African Journals Online (AJOL)

    Morphometric Analysis of Didessa River Catchment in Blue Nile Basin, Western Ethiopia. ... In the present paper an attempt has been made to study the morphometric characteristics of Didessa ... Stream networks and watersheds were delineated in ArcGIS 10.1 software environment by utilizing ... HOW TO USE AJOL.

  8. MORPHOMETRICAL PARAMETERS OF GUT MICROFLORA IN HUMAN VOLUNTEERS

    NARCIS (Netherlands)

    Wilkinson, M.H.F.; Meijer, B.C

    1991-01-01

    The morphology of faecal microflora of nine healthy human volunteers was studied by digital image analysis of microscopic slides. Weekly specimens were collected during an 8-week period. Seven morphometrical parameters were derived: the means and medians of components 1, 2 and 3, and morphometrical

  9. A communicating Thread -CT- case study: JIWY

    NARCIS (Netherlands)

    Jovanovic, D.S.; Hilderink, G.H.; Broenink, Johannes F.; Pascoe, P.W.J.; Loader, R.; Sunderman, V.

    2002-01-01

    This JIWY demonstrator is constructed in the context of the development of a design framework and software tools to efficiently support mechatronic engineers in developing sophisticated control computer code out of a set control laws. We use the CSP-based Communicating Threads -CT- library as the

  10. Retrospective Morphometric Analysis of the Infraorbital Foramen ...

    African Journals Online (AJOL)

    Objective: The aim of our study is to examine the morphometric characteristics of the infraorbital foramen (IOF) and its anatomic localization by using conebeam computerized tomography (CBCT). Materials and Methods: In our study, the anatomic characteristics of the IOF were identified by studying retrospectively the CBCT ...

  11. Study of dosimetry CT in Skull for pediatric patients

    International Nuclear Information System (INIS)

    Ramos Amores, D.; Serna Berna, A.; Mata Colodro, F.; Puchades Puchades, V.

    2013-01-01

    The dose that receiving the patients in CT studies is the highest that can be received in a study of Radiology. If patients are children and we do studies with the same parameters as adults, they will receive a higher dose of radiation. This work seeks to expose the result of a dosimetric study on CT for children aged 0-15, carried out at the Hospital General Universitario de Santa Lucia in Cartagena during the year 2012. (Author)

  12. CT quantitative diagnosis in fatty liver: a clinical study

    International Nuclear Information System (INIS)

    He Wen; Qian Linxue; Zhao Jixue; Ma Daqing; Feng Jie; Hu Zhihai

    2001-01-01

    Objective: To establish the CT criteria of quantitative diagnosis for liver steatosis by means of studying the CT features of fatty liver cases proven histologically. Methods: Twenty-eight cases of fatty liver were underwent non-enhanced CT scan, and the attenuation of liver parenchyma was measured. To differentiate the degree of fatty liver, the mean CT value and the relative density of hepatic vessels were observed. The quantitative diagnosis was made according to the CT number threshold and the criteria of relative density of hepatic vessels, respectively. Results: Among the 28 cases, there were 17 cases of mild steatosis with mean CT number of 46 HU (32-65 HU), 7 cases of middle degree fatty liver with mean CT number of 28 HU (15-38 HU), and 4 cases of sever fatty liver with mean CT number of 0.2 HU (-7-11 HU). For the relative density of hepatic vessels, 16 of the 17 cases of mild fatty liver had a appearance of hepatic vessels immersion and 1 mild case had reverse hepatic vessels display, 6 of 7 middle degree cases had reverse hepatic vessels display with 1 case having the appearance of hepatic vessels immersion, and all the 4 case of sever steatosis had the appearance of reverse hepatic vessels display with sharp contrast between vessels and the liver parenchyma. The accuracy of quantitative diagnosis was 65.9% and 93.1% by means of criteria of CT number threshold and relative density of hepatic vessels, respectively (x 2 = 7.153, P < 0.01). Conclusion: The criteria of relative density of hepatic vessels is more reliable than that of CT number threshold in quantitative diagnosis of fatty liver

  13. Study on broad beam heavy ion CT

    International Nuclear Information System (INIS)

    Ohno, Yumiko; Kohno, Toshiyuki; Sasaki, Hitomi; Nanbu, S.; Kanai, Tatsuaki

    2003-01-01

    To achieve the heavy ion radiotherapy more precisely, it is important to know the distribution of the electron density in a human body, which is highly related to the range of charged particles. From a heavy ion CT image, we can directly obtain the 2-D distribution of the electron density in a sample. For this purpose, we have developed a broad beam heavy ion CT system. The electron density was obtained using some kinds of solutions targets. Also the dependence of the spatial resolution on the target size and the kinds of beams was estimated in this work using cylinders targets of 40, 60 and 80 mm in diameter, each of them has a hole of 10 mm in diameter at the center of it. (author)

  14. CT study of intracionial Wegener's Granulomatosis

    International Nuclear Information System (INIS)

    Yago, M.D.; Torres, T.; Martinez, G.; Lopez, A.; Barrena, R.

    1995-01-01

    Wegener granulamatosis is a multi systemic necrotizing granulomatous vasculitis distinguished from others by its predilection to affect the respiratory tract and the kidneys. Nervous system involvement occurs in 25% of cases, and the most common neurological manifestation is mono neuritis multiplex. However, primary affectation of CNS in an unusual manifestation. We report a case of Wegener Granulomatosis with almost unique neurological manifestation. CT imaging findings of meningeal involvement and retro-orbital pseudotumor are presented. 12 refs

  15. Distribution of Vascular Patterns in Different Subtypes of Renal Cell Carcinoma. A Morphometric Study in Two Distinct Types of Blood Vessels.

    Science.gov (United States)

    Ruiz-Saurí, Amparo; García-Bustos, V; Granero, E; Cuesta, S; Sales, M A; Marcos, V; Llombart-Bosch, A

    2017-07-01

    To analyze the presence of mature and immature vessels as a prognostic factor in patients with renal cell carcinoma and propose a classification of renal cancer tumor blood vessels according to morphometric parameters. Tissue samples were obtained from 121 renal cell carcinoma patients who underwent radical nephrectomy. Staining with CD31 and CD34 was used to differentiate between immature (CD31+) and mature (CD34+) blood vessels. We quantified the microvascular density, microvascular area and different morphometric parameters: maximum diameter, minimum diameter, major axis, minor axis, perimeter, radius ratio and roundness. We found that the microvascular density was higher in CD31+ than CD34+ vessels, but CD34+ vessels were larger than CD31+ vessels, as well as being strongly correlated with the ISUP tumor grade. We also identified four vascular patterns: pseudoacinar, fascicular, reticular and diffuse. Pseudoacinar and fascicular patterns were more frequent in clear cell renal cell carcinoma (37.62 and 35.64% respectively), followed by reticular pattern (21.78%), while in chromophobe tumors the reticular pattern predominated (90%). The isolated pattern was present in all papillary tumors (100%). In healthy renal tissue, the pseudoacinar and isolated patterns were differentially found in the renal cortex and medulla respectively. We defined four distinct vascular patterns significantly related with the ISUP tumor grade in renal cell carcinomas. Further studies in larger series are needed in order to validate these results. Analysis of both mature and immature vessels (CD34+ and CD31+) provides additional information when evaluating microvascular density.

  16. Correlative CT and anatomic study of the sciatic nerve

    International Nuclear Information System (INIS)

    Pech, P.; Haughton, V.

    1985-01-01

    Sciatica can be caused by numerous processes affecting the sciatic nerve or its components within the pelvis including tumors, infectious diseases, aneurysms, fractures, and endometriosis. The CT diagnosis of these causes of sciatica has not been emphasized. This study identified the course and appearance of the normal sciatic nerve in the pelvis by correlating CT and anatomic slices in cadavers. For purposes of discussion, the sciatic nerve complex is conveniently divided into three parts: presacral, muscular, and ischial. Each part is illustrated here by two cryosections with corresponding CT images

  17. Histopathological and morphometric studies on the hooves of dairy and beef cattle in relation to overgrown sole and laminitis.

    Science.gov (United States)

    Singh, S S; Murray, R D; Ward, W R

    1992-10-01

    In dairy cattle, histopathology of the outer hind claws with overgrown sole revealed arteriosclerosis of blood vessels at the ulcer site in the sole. The laminae did not show any hyperplasia of the epidermis and thrombi were not seen in the blood vessels. Partial or complete disappearance of onychogenic substance was observed in the sole as well as in the wall epidermis. In beef animals, typical changes suggestive of chronic laminitis were seen: these included hyperplasia of the epidermis of the laminae, thrombus formation, arteriosclerosis in the corium of the sole, the abaxial wall and the coronary corium. Morphometric analysis quantified measurements of hooves of normal, beef and dairy cattle. It may be concluded that the changes associated with overgrowth of the sole in dairy cattle are localized to the sole without involvement of the laminae and that the term laminitis is not appropriate in the condition seen in dairy cattle.

  18. Morphometric Characterization of Small Cell Lymphocytic Lymphoma

    Directory of Open Access Journals (Sweden)

    Chisoi Anca

    2014-11-01

    Full Text Available The morphometry in histopathology is used to characterize cell populations belonging to different tissues and to identify differences in their parameters with prognostic implications. To achieve morphometric examination were selected 6 of 24 cases identified as small cell lymphocytic lymphoma. For each case analysis was done on five fields, for each field measuring the parameters of 20 cells. The studied parameters were for cytoplasm: cytoplasmic area, maximum and minimum cytoplasmic diameter, cytoplasmic perimeter; for nucleus were measured: nuclear area, minimum and maximum nuclear diameter, nuclear perimeter, nuclear contour index, nuclear ellipticity index, nuclear irregularity index. Also the nucleocytoplasmic ratio was calculated in all studied cases. Small cell lymphocytic lymphoma is characterized in morphometric terms having a small cytoplasmic area (average 29.206 and also a small nuclear area (mean 28.939 having a nucleo-cytoplasmic ratio appearance suggestive for adult lymphocyte. A nuclear contour index small value (3.946, ellipticity index value also small (3.521 and small nuclear irregularity index (3.965. Standard deviations, in any of the studied morphometric categories, is around or below 1 suggesting monomorphic cell appearance. These morphometric and microscopic features characterized mainly by a small population of adult lymphocytes, monomorphic, with rounded hipercromic nuclei, dense chromatin, support the framing into indolent lymphoma group in terms of clinical outcome.

  19. Lung studies with spiral CT. pitch 1 versus pitch 2

    International Nuclear Information System (INIS)

    Sartoni Galloni, S.; Miceli, M.; Lipparino, M.; Burzi, M.; Gigli, F.; Rossi, M.S.; Santoli, G.; Guidarelli, G.

    1999-01-01

    In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality [it

  20. Study on CT changes in autistic children

    International Nuclear Information System (INIS)

    Yaguchi, Katsumi

    1993-01-01

    Since 1979 we have performed CT examinations on 132 autistic children. Neurological diagnosis of the lesion was established by Dr. Segawa's group. On the CT of many autistic children, we found a small low density change located in the anterior wall of the temporal horn, or localized dilatation of the inferior horn near the damaged brain. We reviewed 96 of these patients who all had the obvious low density changes, or localized irregular dilatations in the anterior wall of the temporal horn. By measuring the distance of damage from the midline, we divided the 96 cases into two groups. Group 1 consisted of those with damage located laterally more than 30 mm line from the midline. Group 2 consisted of those with damage medially to the 30 mm line from the midline. Those cases with a large lesion both laterally and medially of the 30 mm line were categorized into group 1. In the adult brain the lateral border of the amygdaloid nucleus was never located laterally more than 30 mm from the midline. Laterally over the 30 mm line there were two marked fiber systems running near the anterior wall of the temporal horn: the fiber of the anterior commissure and the uncinate fascicle. Group 1 consisted of 62 patients and group 2 of 34 patients. The majority of the two group patients were pure autism children. This suggested that the main lesion in autism was in the amygdala. (author)

  1. A morphometric study of measurements of heart in adults and its relation with age and height of the individual: A post-mortem study

    Directory of Open Access Journals (Sweden)

    Chandni Gupta

    2014-01-01

    Full Text Available Objective: Reconstructive and replacement operations of diseased cardiac valves are commonly practiced these days. It may be noted that the choice of proper reconstructive intervention and prosthetic replacement might require the normal morphometric measurements of heart in relation with general body parameters, like age and height. So, this study was undertaken to measure various measurements of heart and its relation with age and height of the individual. Materials and Methods: Sixty five normal post-mortem hearts of adults were taken from the mortuary of Department of Forensic Medicine. Age of the individual was noted. Length of the deceased was measured with a measuring tape from the level of vertex to the outer border of heel. Length (from apex to base, breadth (at broadest diameter and thickness of the heart were measured with slide callipers. Weight was measured with weighing machine. Results: The mean length, breadth, thickness of heart in males and females are 11.25, 8.78, 3.97 cm and 10.60, 8.31, 3.63 cm. The mean weight of heart in males and females was 323 and 276 gms. There was significant correlation with weight of individual and weight of heart in males. There was significant correlation with age of individual and length of heart in females. Conclusion: This study will be helpful for cardiothoracic surgeons while doing surgery on hearts.

  2. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  3. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  4. Studies of extracerebral space on brain CT of infants

    International Nuclear Information System (INIS)

    Shibakiri, Ippei; Furukawa, Takashi; Fukakusa, Shunichi; Nemoto, Yutaka; Takashima, Sumio.

    1983-01-01

    Frontal extracerebral space (ECS) is frequently noticed on brain CT of infants. Based on 70 infants whose initial CTs were available under 1 year of age and who were observed serially by brain CT, we studied the relation between degrees of ECS enlargement and mental and physical development of infants. Development was assessed by clinical observation and the mental test according to Tsumori and Inage at about 1 year of age. 1) Under 1 year of age, ECS was observed both in the normally developed infants and the infants with retarded development. At 1 year of age, CT of the former showed no or only mild widening, but most CT of the latter showed marked dilatation of ECS. 2) Serial observation of brain CT revealed that ECS of normally developed infants tended to reduce at 1 year of age, but that of infants with retarded development did not. 3) Regarding prediction of infantile development, it is important to observe presence of ECS and of the tendency to reduce on brain CT at 1 year of age. 4) Appearance of ECS of normally developed infants is considered to be a physiological phenomenon. (author)

  5. Baseline study of morphometric traits of wild Capsicum annuum growing near two biosphere reserves in the Peninsula of Baja California for future conservation management.

    Science.gov (United States)

    Murillo-Amador, Bernardo; Rueda-Puente, Edgar Omar; Troyo-Diéguez, Enrique; Córdoba-Matson, Miguel Víctor; Hernández-Montiel, Luis Guillermo; Nieto-Garibay, Alejandra

    2015-05-10

    Despite the ecological and socioeconomic importance of wild Capsicum annuum L., few investigations have been carried out to study basic characteristics. The peninsula of Baja California has a unique characteristic that it provides a high degree of isolation for the development of unique highly diverse endemic populations. The objective of this study was to evaluate for the first time the growth type, associated vegetation, morphometric traits in plants, in fruits and mineral content of roots, stems and leaves of three wild populations of Capsicum in Baja California, Mexico, near biosphere reserves. The results showed that the majority of plants of wild Capsicum annuum have a shrub growth type and were associated with communities consisting of 43 species of 20 families the most representative being Fabaceae, Cactaceae and Euphorbiaceae. Significant differences between populations were found in plant height, main stem diameter, beginning of canopy, leaf area, leaf average and maximum width, stems and roots dry weights. Coverage, leaf length and dry weight did not show differences. Potassium, sodium and zinc showed significant differences between populations in their roots, stems and leaves, while magnesium and manganese showed significant differences only in roots and stems, iron in stems and leaves, calcium in roots and leaves and phosphorus did not show differences. Average fruit weight, length, 100 fruits dry weight, 100 fruits pulp dry weight and pulp/seeds ratio showed significant differences between populations, while fruit number, average fruit fresh weight, peduncle length, fruit width, seeds per fruit and seed dry weight, did not show differences. We concluded that this study of traits of wild Capsicum, provides useful information of morphometric variation between wild populations that will be of value for future decision processes involved in the management and preservation of germplasm and genetic resources.

  6. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  7. Retrospective morphometric study of the suitability of renal arteries for renal denervation according to the Symplicity HTN2 trial criteria

    Science.gov (United States)

    Schönherr, Elisabeth; Rehwald, Rafael; Nasseri, Parinaz; Luger, Anna K; Grams, Astrid E; Kerschbaum, Julia; Rehder, Peter; Petersen, Johannes; Glodny, Bernhard

    2016-01-01

    Objective The aim of this study was to describe the renal arteries of humans in vivo, as precisely as possible, and to formulate an expected value for the exclusion of renal denervation due to the anatomical situation based on the criteria of the Symplicity HTN trials. Design and setting In a retrospective cohort study, the renal arteries of 126 patients (57 women, 69 men, mean age 60±17.2 years (CI 57.7 to 63.6)) were segmented semiautomatically from high-contrast CT angiographies. Results Among the 300 renal arteries, there were three arteries with fibromuscular dysplasia and one with ostial renal artery stenosis. The first left renal artery was shorter than the right (34±11.4 mm (CI 32 to 36) vs 45.9±15 mm (CI 43.2 to 48.6); p0.05). The first left renal arteries were 1.1±0.4 mm (CI 0.9 to 1.3), and the first right renal arteries were 0.3±0.6 mm (CI 0.1 to 0.5) thinner in women than in men (p4 mm. Some 46% of the patients, or 58.7% when variants and diseases were taken into consideration, were theoretically not suitable for denervation. Conclusions Based on these precise measurements, the anatomical situation as a reason for ruling out denervation appears to be significantly more common than previously suspected. Since this can be the cause of the failure of treatment in some cases, further development of catheters or direct percutaneous approaches may improve success rates. PMID:26729385

  8. Foot morphometric phenomena.

    Science.gov (United States)

    Agić, Ante

    2007-06-01

    Knowledge of the foot morphometry is important for proper foot structure and function. Foot structure as a vital part of human body is important for many reasons. The foot anthropometric and morphology phenomena are analyzed together with hidden biomechanical descriptors in order to fully characterize foot functionality. For Croatian student population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot morphometric descriptors are influenced by many factors, such as life style, climate, and things of great importance in human society. Dominant descriptors related to fit and comfort are determined by the use 3D foot shape and advanced foot biomechanics. Some practical recommendations and conclusions for medical, sportswear and footwear practice are highlighted.

  9. Aortic non communicating dissections. A study with helical CT

    International Nuclear Information System (INIS)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G.; D'Agostino, D.; De Luca Tupputi Schinosa, L.

    2000-01-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  10. Unravelling the complexity of domestication: a case study using morphometrics and ancient DNA analyses of archaeological pigs from Romania

    Science.gov (United States)

    Evin, Allowen; Flink, Linus Girdland; Bălăşescu, Adrian; Popovici, Dragomir; Andreescu, Radian; Bailey, Douglas; Mirea, Pavel; Lazăr, Cătălin; Boroneanţ, Adina; Bonsall, Clive; Vidarsdottir, Una Strand; Brehard, Stéphanie; Tresset, Anne; Cucchi, Thomas; Larson, Greger; Dobney, Keith

    2015-01-01

    Current evidence suggests that pigs were first domesticated in Eastern Anatolia during the ninth millennium cal BC before dispersing into Europe with Early Neolithic farmers from the beginning of the seventh millennium. Recent ancient DNA (aDNA) research also indicates the incorporation of European wild boar into domestic stock during the Neolithization process. In order to establish the timing of the arrival of domestic pigs into Europe, and to test hypotheses regarding the role European wild boar played in the domestication process, we combined a geometric morphometric analysis (allowing us to combine tooth size and shape) of 449 Romanian ancient teeth with aDNA analysis. Our results firstly substantiate claims that the first domestic pigs in Romania possessed the same mtDNA signatures found in Neolithic pigs in west and central Anatolia. Second, we identified a significant proportion of individuals with large molars whose tooth shape matched that of archaeological (likely) domestic pigs. These large ‘domestic shape’ specimens were present from the outset of the Romanian Neolithic (6100–5500 cal BC) through to later prehistory, suggesting a long history of admixture between introduced domestic pigs and local wild boar. Finally, we confirmed a turnover in mitochondrial lineages found in domestic pigs, possibly coincident with human migration into Anatolia and the Levant that occurred in later prehistory. PMID:25487340

  11. Re-description and Reassignment of the Damselfish Abudefduf luridus (Cuvier, 1830) Using Both Traditional and Geometric Morphometric Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W. James [Washington State Univ., Pullman, WA (United States); Albertson, R Craig [Univ. of Massachusetts, Amherst, MA (United States); Jacob, Rick E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westneat, Mark W. [Field Museum of Natural History, Chicago, IL (United States)

    2014-12-01

    Here we present a re-description of Abudefduf luridus and reassign it to the genus Similiparma. We supplement traditional diagnoses and descriptions of this species with quantitative anatomical data collected from a family-wide geometric morphometric analysis of head morphology (44 species representing all 30 damselfish genera) and data from cranial micro-CT scans of fishes in the genus Similiparma. The use of geometric morphometric analyses (and other methods of shape analysis) permits detailed comparisons between the morphology of specific taxa and the anatomical diversity that has arisen in an entire lineage. This provides a particularly useful supplement to traditional description methods and we recommend the use of such techniques by systematists. Similiparma and its close relatives constitute a branch of the damselfish phylogenetic tree that predominantly inhabits rocky reefs in the Atlantic and Eastern Pacific, as opposed to the more commonly studied damselfishes that constitute a large portion of the ichthyofauna on all coral-reef communities.

  12. Brain atrophy during aging. Quantitative studies with X-CT and NMR-CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuzawa, Taiju; Yamada, Kenji; Yamada, Susumu; Ono, Shuichi; Takeda, Shunpei; Hatazawa, Jun; Ito, Masatoshi; Kubota, Kazuo

    1985-12-01

    Age-related brain atrophy was investigated in thousands of persons with no neurologic disturbances using X-CT and NMR-CT. Brain atrophy was minimal in 34-35 years old in both sexes, increased exponentially to the increasing age after 34-35 years, and probably resulted in dementia, such as vascular or multi-infarct dementia. Brain atrophy was significantly greater in men than in women at all ages. Brain volumes were maximal in 34-35 years old in both sexes with minimal individual differences which increased proportionally to the increasing age. Remarkable individual differences in the extent of brain atrophy (20 - 30 %) existed among aged subjects. Progression of brain atrophy was closely related to loss of mental activities independently of their ages. Our longitudinal study has revealed that the most important factors promoting brain atrophy during aging was the decrease in the cerebral blood flow. We have classified brain atrophy into sulcal and cisternal enlargement type (type I), ventricular enlargement type (type II) and mixed type (type III) according to the clinical study using NMR-CT. Brain atrophy of type I progresses significantly in almost all of the geriatric disorders. This type of brain atrophy progresses significantly in heavy smokers and drinkers. Therefore this type of brain atrophy might be caused by the decline in the blood flow in anterior and middle cerebral arteries. Brain atrophy of type II was caused by the disturbance of cerebrospinal fluid circulation after cerebral bleeding and subarachnoid bleeding. Brain atrophy of type III was seen in vascular dementia or multi-infarct dementia which was caused by loss of brain matter after multiple infarction, and was seen also in dementia of Alzheimer type in which degeneration of nerve cells results in brain atrophy. NMR-CT can easily detect small infarction (lacunae) and edematous lesions resulting from ischemia and hypertensive encephalopathy. (J.P.N.).

  13. Morphometric characteristics in the horseshoe crab Tachypleus gigas (Arthropoda: Merostomata)

    Digital Repository Service at National Institute of Oceanography (India)

    Vijayakumar, R.; Das, S.; Chatterji, A.; Parulekar, A.H.

    comparative morphometry. This study also emphasizes that care must be taken to apply morphometric for a uniform size group of horseshoe crab populations. It is known that the changes in the form of an animal cannot be described satisfactorily...

  14. Morphometric Changes in the Cortical Microvascular Network in Alzheimer's Disease

    NARCIS (Netherlands)

    Richard, E.; van Gool, W.A.; Hoozemans, J.J.M.; van Haastert, E.S.; Eikelenboom, P.; Rozemuller, A.J.M.; van de Berg, W.D.J.

    2010-01-01

    Alzheimer's disease (AD) pathology is accompanied by abnormalities of the microvasculature. Despite the potential importance of morphometric changes in the cortical capillary network on neuronal dysfunction and cognitive impairment, few autopsy studies have addressed this issue. In the present

  15. Morphometric analysis of Dactylorhiza hatagirea (D. Don), a critically ...

    African Journals Online (AJOL)

    The morphometric study was conducted during 2009 to 2010. About 28 morphological characters were measured under 13 natural populations of Dactylorhiza hatagirea. Geographic variation in morphology reflects phenotypic responses to environmental gradients and evolutionary history of populations and species.

  16. Microtomographic and morphometric characterization of a bioceramic bone substitute in dental implantology

    Directory of Open Access Journals (Sweden)

    Deborah Meleo

    2012-01-01

    Full Text Available In recent years, bone tissue regeneration studies have led to a deeper knowledge of chemical and structural features of the best biomaterials to be used as replacements for lost bone structures, with the autologus bone still today the only graft material able to ostegenerate, osteinduct and/or osteoconduct. The difficulties of the small available amount of autologus bone, together with morbidity of a second surgical operation on the same patient, have been overcome using both synthetic and biologic substitute bones. The possibility of investigating morphometric characteristics of substitute bones makes it possible to evaluate the predictability of regenerative processes and, so far, a range of different methods have been used for the purpose. X-ray microtomography (micro-CT is a miniaturized form of conventional tomography, able to analyze the internal structure of small objects, performing three-dimensional images with high spatial resolution (<10 micron pixel size. For a correct analysis, samples need not be altered or treated in any way, as micro-CT is a non-invasive and non-destructive technique. It shows promising results in biomaterial studies and tissue engineering. This work shows the potential applications of this microtomographic technique by means of an in vitro analysis system, in characterizing morphometric features of human bone tissue, and contributes to the use of this technique in studies concerning biomaterials and bioscaffolds inserted in bone tissue.

  17. The Oncogenic Risks of Diagnostic CT Scam Studies in Children

    International Nuclear Information System (INIS)

    Brent, R.

    2004-01-01

    Brenner et al (2001) reported that estimates of the exposure to children from CT scans indicates that the exposures are both higher than from conventional radiographic studies and higher than is necessary to obtain quality examinations. utilizing the oncogenic risk data from the RERF study in Japan, Brenner et al estimated that the oncogenic risk in this population of CT exposed children exposed each year would result in an additional 500 cases of cancer. This risk estimate is supported by the RERF epidemiological data obtained from the populations exposed in Hiroshima and Nagasaki. the increased risks associated with the increased exposure from CT scans have raised concern and stimulated discussion. Although there is little doubt about the benefits of CT scans in improving the health care of children, there is concern about the estimated oncogenic risk, especially since the frequency of CT studies has been increasing. Applying the oncogenic risks of ionizing radiation from the RERF data may not be appropriate for all types of radiation exposure for accurately predicting the incidence of cancer in exposed children because of the impact of 1) partial versus whole-body irradiation, and 2) the protraction of the exposure. Other population of children who have been exposed to radiation and whose incidence of cancer has been studied will be presented and those studies indicate that the risk of cancer is much lower or not increased at all with exposures in the diagnostic range. finally, the dramatic impact of the use of CT scans in clinical pediatric practice saves lives and improves diagnostic accuracy. Therefore, it is crucial that a scholarly evaluation of the risks and benefits should be initiated. The radiology community and the manufacturers have already initiated programs to decrease the exposure significantly. But it is essential that well-planned, retrospective and prospective epidemiology studies should be initiated to study the oncogenic risks. If you want to

  18. ROUNDSCALE SPEARFISH branchiostegal morphometric data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The morphometric characteristics that separate white marlin Kajikia albidus from roundscale spearfish Tetrapturus georgii can be difficult for non-experts to...

  19. Brain atrophy and neuropsychological outcome after treatment of ruptured anterior cerebral artery aneurysms: a voxel-based morphometric study

    International Nuclear Information System (INIS)

    Bendel, Paula; Koskenkorva, Paeivi; Vanninen, Ritva; Koivisto, Timo; Aeikiae, Marja; Niskanen, Eini; Koenoenen, Mervi; Haenninen, Tuomo

    2009-01-01

    Cognitive impairment after aneurysmal subarachnoid hemorrhage (aSAH) is frequently detected. Here, we describe the pattern of cerebral (gray matter) atrophy and its clinical relevance after treatment of aSAH caused by a ruptured anterior cerebral artery (ACA) aneurysm. Thirty-seven aSAH patients with ACA aneurysm (17 surgical, 20 endovascular treatment) and a good or moderate clinical outcome (Glasgow Outcome Scale V or IV) and 30 controls underwent brain MRI. Voxel-based morphometric analysis was applied to compare the patients and controls. Patients also underwent a detailed neuropsychological assessment. The comparisons between controls and either all patients (n=37) or the subgroup of surgically treated patients (n=17) revealed bilateral cortical atrophy in the frontal lobes, mainly in the basal areas. The brainstem, bilateral thalamic and hypothalamic areas, and ipsilateral caudate nucleus were also involved. Small areas of atrophy were detected in temporal lobes. The hippocampus and parahippocampal gyrus showed atrophy ipsilateral to the surgical approach. In the subgroup of endovascularly treated patients (n = 15), small areas of atrophy were detected in the bilateral orbitofrontal cortex and in the thalamic region. Twenty patients (54%) showed cognitive deficits in neuropsychological assessment. Group analysis after aSAH and treatment of the ruptured ACA aneurysm revealed gray matter atrophy, principally involving the frontobasal cortical areas and hippocampus ipsilateral to the surgical approach. Areas of reduced gray matter were more pronounced after surgical than endovascular treatment. Together with possible focal cortical infarctions and brain retraction deficits in individual patients, this finding may explain the neuropsychological disturbances commonly detected after treatment of ruptured ACA aneurysms. (orig.)

  20. Brain atrophy and neuropsychological outcome after treatment of ruptured anterior cerebral artery aneurysms: a voxel-based morphometric study

    Energy Technology Data Exchange (ETDEWEB)

    Bendel, Paula; Koskenkorva, Paeivi; Vanninen, Ritva [Kuopio University Hospital and University of Kuopio, Department of Clinical Radiology, Kuopio (Finland); Koivisto, Timo; Aeikiae, Marja [Kuopio University Hospital and University of Kuopio, Department of Neurosurgery, Kuopio (Finland); Niskanen, Eini [Kuopio University Hospital and University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital and University of Kuopio, Department of Physics, Kuopio (Finland); Koenoenen, Mervi [Kuopio University Hospital and University of Kuopio, Department of Clinical Radiology, Kuopio (Finland); Kuopio University Hospital and University of Kuopio, Department of Clinical Neurophysiology, Kuopio (Finland); Haenninen, Tuomo [Kuopio University Hospital and University of Kuopio, Department of Neurology, Kuopio (Finland)

    2009-11-15

    Cognitive impairment after aneurysmal subarachnoid hemorrhage (aSAH) is frequently detected. Here, we describe the pattern of cerebral (gray matter) atrophy and its clinical relevance after treatment of aSAH caused by a ruptured anterior cerebral artery (ACA) aneurysm. Thirty-seven aSAH patients with ACA aneurysm (17 surgical, 20 endovascular treatment) and a good or moderate clinical outcome (Glasgow Outcome Scale V or IV) and 30 controls underwent brain MRI. Voxel-based morphometric analysis was applied to compare the patients and controls. Patients also underwent a detailed neuropsychological assessment. The comparisons between controls and either all patients (n=37) or the subgroup of surgically treated patients (n=17) revealed bilateral cortical atrophy in the frontal lobes, mainly in the basal areas. The brainstem, bilateral thalamic and hypothalamic areas, and ipsilateral caudate nucleus were also involved. Small areas of atrophy were detected in temporal lobes. The hippocampus and parahippocampal gyrus showed atrophy ipsilateral to the surgical approach. In the subgroup of endovascularly treated patients (n = 15), small areas of atrophy were detected in the bilateral orbitofrontal cortex and in the thalamic region. Twenty patients (54%) showed cognitive deficits in neuropsychological assessment. Group analysis after aSAH and treatment of the ruptured ACA aneurysm revealed gray matter atrophy, principally involving the frontobasal cortical areas and hippocampus ipsilateral to the surgical approach. Areas of reduced gray matter were more pronounced after surgical than endovascular treatment. Together with possible focal cortical infarctions and brain retraction deficits in individual patients, this finding may explain the neuropsychological disturbances commonly detected after treatment of ruptured ACA aneurysms. (orig.)

  1. Fundamental studies for CT in the oral region

    International Nuclear Information System (INIS)

    Suzuki, Shinichiro

    1984-01-01

    Fundamental studies were attempted regarding the clinical application of CT (TCT-60A) in the oral region. The investigation assessed the following: 1) calculation of CT-No for oral hard tissues, 2) test for linearity CT-No vs. the linear attenuation coefficient in high X-ray attenuation materials, 3) observation of artifacts caused by dental materials and 4) measurement of patient doses of CT used at the maxillary sinus. The results obtained were as follows. 1) Calculated CT-No (E=70 KeV) values for oral hard tissues were enamel 3.51 x 10 3 , dentine 2.40 x 10 3 , cementum 1.88 x 10 3 , cortical bone 1.48 x 10 3 and mandible 1.01 x 10 3 . 2) Linearity for CT-No vs. the linear attenuation coefficient gave a good relative coefficient between lucite and teflon, but linearity between lucite and aluminum was not good enough. 3) Three different artifacts from the copper rod were observed: (1) connection line artifact, (2) star-burst artifact and (3) figure-eight artifact. 4) Under shot caused by composite resin was observed, and artifact from both the radiopaque composite resin and amalgam were the same kinds as those from the copper rod. 5) Calculated CT-No (E=66 KeV) values for dental materials were copper 5.48 x 10 4 , composite resin 1.24 x 10 3 , radiopaque composite resin 4.65 x 10 3 and amalgam 2.27 x 10 5 . 6) Absorbed doses of lenses and thyroid gland using CT at the mixillary sinus region were 59 mrad (59 x 10 -2 mGy) and 17 mrad (17 x 10 -2 mGy) for a single scanning. 7) The volume dose of the head under a single CT scanning was estimated as 820 g.rad (820 x 10 -5 Kg.Gy) by the TLD method, and 900 g.rad (900 x 10 -5 Kg.Gy) by the film dosimetry method. The difference in these values was considered to be the effect arising from ununiformity of the X-ray beam. (author)

  2. Hepatic alveolar echinococcosis: correlative US and CT study

    Energy Technology Data Exchange (ETDEWEB)

    Didier, D.; Weiler, S.; Rohmer, P.; Lasseque, A.; Deschamps, J.P.; Vuitton, D.; Miguet, J.P.; Weill, F.

    1985-01-01

    A total of 24 cases of hepatic alveolar echinococcosis (HAE) due to Echinococcus multilocularis was assessed by US and CT. The diagnosis was confirmed in all cases by immunologic and histologic study. Both US and CT patterns of HAE showed changes of liver morphology in both contour and size. Abnormal areas of parenchyma were nodular or in fields, irregular, heterogeneous, and basically echogenic. Clustered microcalcifications were encountered within the abnormal parenchymal fields in 50% of cases, and necrotized zones occurred in 40% of cases. Dilatation of intrahepatic bile ducts was commonly seen, especially on US; hilar involvement was frequent. Follow-up by both techniques can display increases of primary lesions, occurrence of new foci, and local or regional extensions. Precise evaluations of the lesions arising from correlative use of US and CT permits adequate therapeutic management.

  3. CT study in primary low spinal fluid pressure syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hoshino, Moritoshi; Okayama, Kenji; Kubo, Hiromasa; Watanabe, Hiromi; Endou, Riuko (Ohmiya Red Cross Hospital, Yono, Saitama (Japan))

    1991-02-01

    CT findings in primary low spinal fluid pressure syndrome were studied on the basis of 3 cases. Case 1 was a 43-year-old male with a complicated bilateral isodense subdural hematoma (SDH). Case 2 was a 45-year-old female with a complicated bilateral high dense SDH. Case 3 was a 36-year-old female discharged without any complications after spinal fluid pressure normalized. Slight downward displacement of the brain under low spinal fluid pressure was shown as the narrowing of a Sylvian fissures and infratentorial cisterns on CT. On the other hand, in this syndrome with a complicated bilateral isodense SDH, in addition to this finding, CT revealed distortion and narrowing of body lateral ventricles, which might be differential findings from this syndrome without complicated SDH. Under low spinal fluid pressure, bridging veins are more stretched by a downward displacement of the brain. And consequently they were easily injured and SDH was developed. (author).

  4. Hepatic alveolar echinococcosis: correlative US and CT study

    International Nuclear Information System (INIS)

    Didier, D.; Weiler, S.; Rohmer, P.; Lasseque, A.; Deschamps, J.P.; Vuitton, D.; Miguet, J.P.; Weill, F.

    1985-01-01

    A total of 24 cases of hepatic alveolar echinococcosis (HAE) due to Echinococcus multilocularis was assessed by US and CT. The diagnosis was confirmed in all cases by immunologic and histologic study. Both US and CT patterns of HAE showed changes of liver morphology in both contour and size. Abnormal areas of parenchyma were nodular or in fields, irregular, heterogeneous, and basically echogenic. Clustered microcalcifications were encountered within the abnormal parenchymal fields in 50% of cases, and necrotized zones occurred in 40% of cases. Dilatation of intrahepatic bile ducts was commonly seen, especially on US; hilar involvement was frequent. Follow-up by both techniques can display increases of primary lesions, occurrence of new foci, and local or regional extensions. Precise evaluations of the lesions arising from correlative use of US and CT permits adequate therapeutic management

  5. Normal sacroiliac joint: a CT study of asymptomatic patients

    International Nuclear Information System (INIS)

    Vogler, J.B. III; Brown, W.H.; Helms, C.A.; Genant, H.K.

    1984-01-01

    The sacroiliac (SI) joints of 45 asymptomatic subjects were prospectively studied to define better the normal appearance of SI joints on CT scans and therby attach appropriate significance to CT signs of sacroiliitis. Joint space narrowing, subchondral sclerosis, erosions, ankylosis, osteophytes, subchondral cysts, and symmetry were evaluted. The results indicate that the SI joints demonstrate symmetry in patients under the age of 30 (100% of subjects in this age group). Those CT findings of sacroiliitis that occurred infrequently in the asymptomatic population, and hence may represent good indicators of sacroiliac disease, include increased sacral subchondral sclerosis in subjects under the age of 40 (11%), bilateral or unilateral uniform joint space of less than 2 mm (2% or 0%, respectively), erosions (2%), and intraarticular ankylosis (0%)

  6. Study of CT image texture using deep learning techniques

    Science.gov (United States)

    Dutta, Sandeep; Fan, Jiahua; Chevalier, David

    2018-03-01

    For CT imaging, reduction of radiation dose while improving or maintaining image quality (IQ) is currently a very active research and development topic. Iterative Reconstruction (IR) approaches have been suggested to be able to offer better IQ to dose ratio compared to the conventional Filtered Back Projection (FBP) reconstruction. However, it has been widely reported that often CT image texture from IR is different compared to that from FBP. Researchers have proposed different figure of metrics to quantitate the texture from different reconstruction methods. But there is still a lack of practical and robust method in the field for texture description. This work applied deep learning method for CT image texture study. Multiple dose scans of a 20cm diameter cylindrical water phantom was performed on Revolution CT scanner (GE Healthcare, Waukesha) and the images were reconstructed with FBP and four different IR reconstruction settings. The training images generated were randomly allotted (80:20) to a training and validation set. An independent test set of 256-512 images/class were collected with the same scan and reconstruction settings. Multiple deep learning (DL) networks with Convolution, RELU activation, max-pooling, fully-connected, global average pooling and softmax activation layers were investigated. Impact of different image patch size for training was investigated. Original pixel data as well as normalized image data were evaluated. DL models were reliably able to classify CT image texture with accuracy up to 99%. Results show that the deep learning techniques suggest that CT IR techniques may help lower the radiation dose compared to FBP.

  7. Geometric morphometric footprint analysis of young women

    OpenAIRE

    Domjanic, Jacqueline; Fieder, Martin; Seidler, Horst; Mitteroecker, Philipp

    2013-01-01

    Background Most published attempts to quantify footprint shape are based on a small number of measurements. We applied geometric morphometric methods to study shape variation of the complete footprint outline in a sample of 83 adult women. Methods The outline of the footprint, including the toes, was represented by a comprehensive set of 85 landmarks and semilandmarks. Shape coordinates were computed by Generalized Procrustes Analysis. Results The first four principal components represented t...

  8. Anatomic study of celiac ganglia using CT in cadavers

    International Nuclear Information System (INIS)

    Zhao Qionghui; Zhang Xiaoming; Zeng Nanlin; Cai Changping; Xie Xingguo; Li Chengjun

    2005-01-01

    Objective: To identify the celiac ganglia in cadavers by using current CT techniques, and to facilitate its identification in vivo by CT. Methods: Fifty cadavers were dissected, moving peritoneal organs such as liver and stomach to expose the celiac ganglia. The location, morphology, and dimensions of celiac ganglia, and their relationship to abutting structures, were noted. The celiac ganglia in 6 of the 50 cadavers without peripancreatic diseases and with clear anatomy were isolated and marked with yellow dye and Iohexol injection. In these 6 cadavers, the moved organs were relocated, the abdomen was closed, and CT was performed. CT derived measurements of celiac ganglia were compared with those from cadavers study. Results: The celiac ganglia of 47 of 50 cadavers (94%) were located between T12-L1, and those of 3 cadavers (6%) were located between T11-12. The superior-inferior diameter of the right ganglia was (25.01 ±6.09) mm, long (left-right) diameter was (13.18 ± 3.62) mm, and short (thickness) diameter was (1.40 ± 0.55) mm. In the left ganglia, these three diameters were (22.74 ± 5.70) mm, (15.07 ± 4.35) mm, and (2.00 ± 0.71 ) mm, respectively. On the CT images of 6 cadavers, the right and left ganglia were all identified and were hyperdense relative to viscus, such as liver and spleen. The long and short diameters on CT images were (15.20 ± 1.64) mm and (1.53 ± 0.52) mm for the right ganglia and (16.25 ± 1.73 ) mm and (2.20 ± 0.73) mm for the left ganglia. There was no significant difference between the diameters of the ganglia measured on CT images and by dissection (P>0.05). Conclusion: Current CT techniques can demonstrate accurately the celiac ganglia in cadavers. This can be a reference for identifying the celiac plexus in vivo. (authors)

  9. Digital Morphometrics: A New Upper Airway Phenotyping Paradigm in OSA.

    Science.gov (United States)

    Schwab, Richard J; Leinwand, Sarah E; Bearn, Cary B; Maislin, Greg; Rao, Ramya Bhat; Nagaraja, Adithya; Wang, Stephen; Keenan, Brendan T

    2017-08-01

    OSA is associated with changes in pharyngeal anatomy. The goal of this study was to objectively and reproducibly quantify pharyngeal anatomy by using digital morphometrics based on a laser ruler and to assess differences between subjects with OSA and control subjects and associations with the apnea-hypopnea index (AHI). To the best of our knowledge, this study is the first to use digital morphometrics to quantify intraoral risk factors for OSA. Digital photographs were obtained by using an intraoral laser ruler and digital camera in 318 control subjects (mean AHI, 4.2 events/hour) and 542 subjects with OSA (mean AHI, 39.2 events/hour). The digital morphometric paradigm was validated and reproducible over time and camera distances. A larger modified Mallampati score and having a nonvisible airway were associated with a higher AHI, both unadjusted (P digital morphometrics is an accurate, high-throughput, and noninvasive technique to identify anatomic OSA risk factors. Morphometrics may also provide a more reproducible and standardized measurement of the Mallampati score. Digital morphometrics represent an efficient and cost-effective method of examining intraoral crowding and tongue size when examining large populations, genetics, or screening for OSA. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  10. Reproducibility of morphometric X-ray absorptiometry

    International Nuclear Information System (INIS)

    Culton, N.; Pocock, N.

    1999-01-01

    Full text: Morphometric X-ray absorptiometry (MXA) using DXA is potentially a useful clinical tool which may provide additional vertebral fracture information with low radiation exposure. While morphometric analysis is semi-automated, operator intervention is crucial for the accurate positioning of the six data points quantifying the vertebral heights at the anterior, middle and posterior positions. Our study evaluated intra-operator reproducibility of MXA in an elderly patient population and assessed the effect of training and experience on vertebral height precision. Ten patients, with a mean lumbar T score of - 2.07, were studied. Images were processed by a trained operator who had initially only limited morphometric experience. The analysis of the data files were repeated at 2 and 6 weeks, during which time the operator had obtained further experience and training. The intra-operator precision of vertebral height measurements was calculated using the three separate combinations of paired analyses, and expressed as the coefficient of variation. This study confirms the importance of adequate training and attention to detail in MXA analysis. The data indicate that the precision of MXA is adequate for its use in the diagnosis of vertebral fractures, based on a 20% deformity criteria. Use of MXA for monitoring would require approximately an 8% change in vertebral heights to achieve statistical significance

  11. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  12. Patient dosimetry study of a paediatric CT examination

    International Nuclear Information System (INIS)

    Hranitzky, C.; Stadtmann, H.

    2011-01-01

    Dosimetry studies are of increasing interest in diagnostic high-dose applications such as computed tomography especially for examinations of children. A routine CT scan protocol for paediatric head and neck imaging was investigated at a new multi-detector CT scanner using LiF:Mg,Cu,P thermoluminescence dosemeters (TLDs) and a 0.125 cm 3 thimble ionization chamber. Calibrations of the detectors in terms of absorbed dose to water were carried out at the Dosimetry Laboratory Seibersdorf in standard radiation fields. The dosimetry method was validated in the spiral CT X-ray field by comparing TLD and ionization chamber measurement results in cylindrical PMMA phantoms. Absorbed dose results were within stated uncertainties. An anthropomorphic phantom representing a child of about 5 years was loaded with TLD chips at various organ and tissue positions in the head and neck region as well as at some critical organ locations. Organ dose values were calculated from TLD based average absorbed dose with about 5% total uncertainty, e.g. 22 mGy (eyes), 21 mGy (thyroid), 19 mGy (brain), 3.4 mGy (thymus), and 0.03 mGy (testes). For comparison purposes an effective dose of 1.9 mSv was estimated for the investigated paediatric CT examination based on ICRP-103 age-independent tissue-weighting factors.

  13. Normal development of paranasal sinuses in children: A CT study

    International Nuclear Information System (INIS)

    Kim, Hyung Jin; Park, Eui Dong; Choi, Pil Youb; Kim, Jae Hyoung; Chung, Sung Hoon; Chung, Hae Gyeong

    1993-01-01

    To evaluate the normal development of the paranasal sinuses in children with CT, authors prospectively studied with brain CT scans of 260 children without known sinus disease, ranging image from 7 days to 16 years. Maximal anteroposterior and transverse diameters(mm) and maximal cross- sectional area(mm 2 ) of both sides of the maxillary sinus were measured with the aid of computer device. As to the ethmoidal and spheroidal sinuses, we simply documented the presence of the aplastic ethmoidal sinus and calculated the age-incidence of the spheroidal sinus pneumatization, respectively.There noted three phases in the development of the maxillary sinus. The anteroposterior and transverse diameters of the maxillary sinus increased nearly in parallel. The former was always greater than the latter. In no cases was the edathamil sinus aplastic and almost all sinuses were pneumatized even in infants as early as 7 old days. CT identified the conchal pattern of sphenoidal sinus pneumatization infants as early as 11 days old. Sphenoidal sinus pneumatization was seen in 38% of the children under the age of 1 year, 82% of the children between the age of 1 and 2 years, and almost all children older than 2 years. The anteroposterior and transverse diameters of the maxillary sinus seem to reach the adult size by 8 years of age, and the conchal pattern of sphemoidal sinus pneumatization can be recognized earlier with CT than on the plain radiographs

  14. Differentiation of sympatric zebra and quagga mussels in ecotoxicological studies: A comparison of morphometric data, gene expression, and body metal concentrations.

    Science.gov (United States)

    Kerambrun, E; Delahaut, L; Geffard, A; David, E

    2018-06-15

    The zebra mussel is among the best studied freshwater molluscs in ecotoxicology, but information on the quagga mussel is lacking. Considering its potential spread, we selected a river in France in which zebra and quagga mussels coexisted, and then we used genetic markers to differentiate the two species and compared morphological parameters. cDNA sequencing assays of ten genes already used in zebra mussels were performed on quagga mussels to obtain functional specific primers. Then we analyzed the expression of genes involved in cellular metabolic activities (Cytochrome-c-oxidase - cox, and ATP synthase - atp), detoxification processes (Glutathione-S-Transferase - gst), oxidative stress (Catalase - cat), and digestive functions (Amylase - amy) on the two species. Whereas morphometric analysis underlined similarities in shape between the two species, relative gene expression profiles and metal concentrations evidenced strong differences. Quagga mussels notably presented half as high concentrations in Cd and Pb, two particularly toxic elements, as zebra mussels. These results imply that i) particular attention should be paid to properly distinguish the two species considering their similar external appearance, and ii) zebra mussels cannot be replaced by quagga mussels in ecotoxicological studies without preliminary investigations on biomarker response patterns. To our knowledge, this study is the first to have undertaken such an approach in gene expression analysis in quagga mussels, and more generally to have compared such biomarker responses of zebra and quagga mussels in the field. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  16. A morphometric, immunohistochemical, and in situ hybridization study of the dorsal raphe nucleus in major depression, bipolar disorder, schizophrenia, and suicide.

    Science.gov (United States)

    Matthews, Paul R; Harrison, Paul J

    2012-03-01

    Several lines of evidence implicate 5-hydroxytryptamine (5-HT, serotonin) in the pathophysiology of mood disorders and suicide. However, it is unclear whether these conditions include morphological involvement of the dorsal raphe nucleus (DRN), the origin of most forebrain 5-HT innervation. We used morphometric, immunohistochemical, and molecular methods to compare the DRN in post-mortem tissue of 50 subjects (13 controls, 14 major depressive disorder [MDD], 13 bipolar disorder, 10 schizophrenia; 17 of the cases died by suicide). NeuN and PH8 antibodies were used to assess all neurons and serotonergic neurons respectively; 5-HT(1A) autoreceptor expression was investigated by regional and cellular in situ hybridization. Measurements were made at three rostrocaudal levels of the DRN. In MDD, the area of the DRN was decreased. In bipolar disorder, serotonergic neuronal size was decreased. Suicide was associated with an increased DRN area, and with a higher density but decreased size of serotonergic neurons. Total neuronal density and 5-HT(1A) receptor mRNA abundance were unaffected by diagnosis or suicide. No changes were seen in schizophrenia. The results show that mood disorders and suicide are associated with differential, limited morphological alterations of the DRN. The contrasting influences of MDD and suicide may explain some of the discrepancies between previous studies, since their design precluded detection of the effect. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. In vitro H2O2 stress and patterns of mitochondrial damage in the NCTC 2544 continuous cell line--a morphologic and morphometric study.

    Science.gov (United States)

    Pugnaloni, A; Giantomassi, F; Armeni, T; Serresi, M; Principato, G; Fazioli, F; Biagini, G

    2004-01-01

    The morpho-functional and energy condition of NCTC 2544 cells exposed for 1 hr to a high concentration of H2O2 (500 microM) was studied at 4 and 24 hr to investigate the short- and medium-term biomolecular mechanisms affecting energetic mitochondrial capability. Morphometric data obtained from ultrastructural investigations clearly showed significant modifications of the different mitochondrial parameters--numerical density (Nv), volume density (Vv) and Vv/Nv ratio, in interkinetic, apoptotic and mitotic cells after H2O2 exposure (from 4 to 24 hr). These results were confirmed by the detection at 24 hr of mitochondrial cytochrome c release in the cytosol, indicating impairment in mitochondrial membrane permeability. Data supporting these observations were obtained from the MTT test which showed reduced cell viability in H2O2 treated cultures at 4 hr and an even greater decrement at 24 hr. In conclusion our data imply that significant cause-effect relationships exist between the toxicity of reactive oxygen species (i.e. 500 microM H2O2) and morpho-structural mitochondrial damage in interkinetic, apoptotic and mitotic cells, respectively. They support previous results present both in the literature and also in one of our earlier papers which show that early nuclear DNA damage could initiate mitochondrial or intrinsic apoptotic pathway after H2O2 exposure.

  18. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  19. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  20. CT study in senile dementia of Alzheimer type

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ryoichi; Otomo, Eiichi [Yokufukai Geriatric Hospital, Tokyo (Japan)

    1989-10-01

    In order to evaluate the utility of cranial CT in diagnosis of senile dementia of Alzheimer type (SDAT), various CT findings were studied. CT scans of 62 cases of SDAT (83{plus minus}6 years old) were compared with those of 357 aged cases (means 78{plus minus}8 years old) without psychiatric and/or neurological illness (NC). To evaluate CT findings linear measurements of the ventricle, observation of sulci, brain atrophy ranking of microscopic observation were compared along with presence of periventricular lucency. When SDAT were compared with NC, the cases were divided into two groups by the age (the eighth decade, 80 years old or over) to avoid the influence of physiological brain atrophy. In SDAT there was a positive correlation between the volume of the lateral ventricle in autopsy brain and each index which demonstrates the size of the lateral ventricle on CT. In SDAT the incidence of cases with degree III or more was significantly higher than that in NC. It was 82.6% in SDAT, 15.7% in NC in the eighth decade and 92.3% in SDAT, 32.1% in NC in 80 years or over. The mean values of indexes of lateral ventricle enlargement in SDAT increased more than those in NC. In the eighth decade the mean lateral body ratio was 33.8% in SDAT, and 27.0% in NC and in 80 years or over, it was 33.1% in SDAT, 28.1% in NC. The differences between SDAT and NC were statistically significant. In SDAT the incidence of PVL was significantly higher than in NC. The mean maximum width of Sylvian fissure in SDAT was significantly larger than those in NC. However, the width of cingulate sulcus and central sulcus in SDAT were similar to those of NC. Brain atrophy ranking tended to increase with aging in SDAT, but this tendency was less clear than that in NC. In SDAT temporal atrophy was more significant than the other areas. Overall, CT revealed that brain atrophy in stage III patients was more remarkable than that in stage II patients.

  1. CT study in senile dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Yoshida, Ryoichi; Otomo, Eiichi

    1989-01-01

    In order to evaluate the utility of cranial CT in diagnosis of senile dementia of Alzheimer type (SDAT), various CT findings were studied. CT scans of 62 cases of SDAT (83±6 years old) were compared with those of 357 aged cases (means 78±8 years old) without psychiatric and/or neurological illness (normal control NC). The methods of evaluating CT findings were linear measurements of the ventricle, observation of sulci, brain atrophy ranking of microscopic observation, and presence of periventricular lucency. When SDAT were compared with NC, the cases were divided into two groups by the age (the eighth decade, 80 years old or over) to avoid the influence of physiological brain atrophy. In SDAT there was a positive correlation between the volume of the lateral ventricle in autopsy brain and each index which demonstrates the size of the lateral ventricle on CT. In SDAT the incidence of cases with degree III or more was significantly higher than that in NC. It was 82.6% in SDAT, 15.7% in NC in the eighth decade and 92.3% in SDAT, 32.1% in NC in 80 years or over. The mean values of indexes of lateral ventricle enlargement in SDAT increased more than those in NC significantly. In the eighth decade the mean lateral body ratio was 33.8% in SDAT, and 27.0% in NC and in 80 years or over, it was 33.1% in SDAT, 28.1% in NC. The differences between SDAT and NC were statistically significant. In SDAT the incidence of PVL was significantly higher than in NC. The mean maximum width of Sylvian fissure in SDAT was significantly larger than those in NC. However, the width of cingulate sulcus and central sulcus in SDAT were similar to those of NC. Brain atrophy ranking tended to increase with aging in SDAT, but this tendency was less clear than that in NC. In SDAT temporal atrophy was significantly remarkable than the other areas. Overall, CT revealed that brain atrophy in stage III patients was more remarkable than that in stage II patients. (J.P.N.)

  2. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  3. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    Science.gov (United States)

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  4. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  5. Symmetry analysis of talus bone: A Geometric morphometric approach.

    Science.gov (United States)

    Islam, K; Dobbe, A; Komeili, A; Duke, K; El-Rich, M; Dhillon, S; Adeeb, S; Jomha, N M

    2014-01-01

    The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones. Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified. Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery. We conclude that left and right talus bones of intact human ankle joints show a strong degree of symmetry. The results of this study may have significance with respect to talus surgery, and in investigating traumatic talus injury where the geometric shape of the contralateral talus can be used as control. Cite this article: Bone Joint Res 2014;3:139-45.

  6. CT-guided suprascapular nerve blocks: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A. [Department of Medical Imaging, Victoria House Private Hospital, 316 Malvern Road, Prahran 3181, Melbourne, Victoria (Australia)

    2004-05-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean ({+-}SEM) pain score of 7.0 ({+-}0.4) to 3.5 ({+-}0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% ({+-}4.9, P<0.001) and 16.8% ({+-}4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  7. CT-guided suprascapular nerve blocks: a pilot study

    International Nuclear Information System (INIS)

    Schneider-Kolsky, M.E.; Pike, J.; Connell, D.A.

    2004-01-01

    The objective of this study was to describe the suprascapular nerve block using CT guidance and to evaluate the short- and medium-term efficacy in a range of shoulder pathologies. CT-guided infiltration around the suprascapular nerve was performed with bupivacaine and Celestone Chronodose on 40 consecutive patients presenting with chronic shoulder pathologies unresponsive to conventional treatment. Patients were interviewed using the Shoulder Pain and Disability Index (SPADI) before the procedure, 30 min after the procedure and at 3 days, 3 weeks and 6 weeks afterwards. Within 30 min of the block overall pain scores decreased from a mean (±SEM) pain score of 7.0 (±0.4) to 3.5 (±0.5) (n=39, P<0.001). At 3 days after the procedure, the mean overall improvement of the pain and disability scores were 20.4% (±4.9, P<0.001) and 16.8% (±4.8, P=0.004) respectively. Sustained pain relief and reduced disability were achieved in 10 of 35 (29%) patients at 3 weeks and longer. Patients suffering from soft tissue pathologies were the most likely patients to benefit from the injection. No serious side effects were noted. In some patients with chronic soft tissue pathologies who do not respond to conventional treatment, a CT-guided suprascapular nerve block can provide safe short- and medium-term relief from pain and disability. (orig.)

  8. PET/CT and contrast enhanced CT in single vs. two separate sessions: a cost analysis study.

    Science.gov (United States)

    Picchio, M; Mansueto, M; Crivellaro, C; Guerra, L; Marcelli, S; Arosio, M; Sironi, S; Gianolli, L; Grimaldi, A; Messa, C

    2012-06-01

    Aim of the study was to quantify the economic impact of PET/CT and contrast enhanced (c.e.) CT performed in a single session examination vs. stand-alone modalities in oncological patients. One-hundred-forty-five cancer patients referred to both PET/CT and c.e. CT, to either stage (N.=46) or re-stage (N.=99) the disease, were included. Seventy-two/145 performed both studies in a single session (innovative method) and 73/145 in two different sessions (traditional method). The cost-minimization analysis was performed by evaluating: 1) institutional costs, data obtained by hospital accountability (staff, medical materials, equipment maintenance and depreciation, departments utilities); 2) patients costs, data obtained by a specific survey provided to patients (travel, food, accommodation costs, productivity loss). Economic data analysis showed that the costs for innovative method was lower than those of traditional method, both for Institution (106 € less per test) and for patient (21 € less per patient). The loss of productivity for patient and caregivers resulted lower for the innovative method than the traditional method (3 work-hour less per person). PET/CT and c.e. CT performed in a single session is more cost-effective than stand-alone modalities, by reducing both Institutional and patients costs. These advantages are mainly due to lower Institutional cost (single procedure) and to lower cost related to travel and housing.

  9. Refining experimental dental implant testing in the Göttingen Minipig using 3D computed tomography-A morphometric study of the mandibular canal.

    Directory of Open Access Journals (Sweden)

    Giuliano M Corte

    Full Text Available This study reports morphometric and age-related data of the mandibular canal and the alveolar ridge of the Göttingen Minipig to avoid complications during in vivo testing of endosseus dental implants and to compare these data with the human anatomy. Using 3D computed tomography, six parameters of the mandibular canal as well as the alveolar bone height and the alveolar ridge width were measured in Göttingen Minipigs aged 12, 17 and 21 months. Our null hypothesis assumes that the age and the body mass have an influence on the parameters measured. The study found that the volume, length and depth of the mandibular canal all increase with age. The width of the canal does not change significantly with age. The body mass does not have an influence on any of the measured parameters. The increase in canal volume appears to be due to loss of deep spongy bone in the posterior premolar and molar regions. This reduces the available space for dental implantations, negatively affecting implant stability and potentially the integrity of the inferior alveolar neurovascular bundle. Dynamic anatomical changes occur until 21 months. On ethical grounds, using minipigs younger than 21 months in experimental implant dentistry is inadvisable. Paradoxically the measurements of the 12 months old pigs indicate a closer alignment of their mandibular anatomy to that of humans suggesting that they may be better models for implant studies. Given the variability in mandibular canal dimensions in similar age cohorts, the use of imaging techniques is essential for the selection of individual minipigs for dental prosthetic interventions and thus higher success rates.

  10. Morphometric study of suprascapular notch in Indian dry scapulae with specific reference to the incidence of completely ossified superior transverse scapular ligament.

    Science.gov (United States)

    Kannan, Usha; Kannan, N S; Anbalagan, J; Rao, Sudha

    2014-03-01

    The suprascapular notch, a depression on the lateral part of the superior border of the scapula, medial to the coracoid process, is bridged by the superior transverse scapular ligament, which is sometimes ossified and the foramen which is thus completed, transmits the suprascapular nerve to the supraspinatus fossa. Variations in the morphology of suprascapular notch have been identified as one of the causes of suprascapular nerve entrapment. Rengachary et al. classified this notch into six types, based on its shape. To study morphological variations of suprascapular notch in Indian dry scapulae and to analyze the incidence of completely ossified superior transverse scapular ligament with other ethnic populations which have been cited earlier. A total of 400 human dry scapulae which were obtained from the Department of Anatomy of selected eight medical colleges were analyzed. The type of suprascapular notch was noted and it was recorded as per the description given by Rengachary et al. The results of the present study were compared with the results of previous authors in different populations. In our study, out of 400 scapulae, 40 (10%), were identified to have completely ossified superior transverse scapular ligaments. The frequencies of various types of suprascapular notches were: Type I -20%, Type II -10%, Type III -52%, Type IV -4%, Type V -4%, Type VI -10%. Since the suprascapular nerve entrapment syndrome might be caused by complete ossification of superior transverse scapular ligament with formation of suprascapular foramen and other morphometric variations of suprascapular notch, the knowledge on such variations is essential for clinicians, for making a proper diagnosis and for planning the most suitable surgical intervention.

  11. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  12. Evaluation of recovery in hydronephrosis using renal functional CT studies

    International Nuclear Information System (INIS)

    Watanabe, Kiyotaka

    1985-01-01

    Using renal functional CT studies, we studied 22 patients who underwent surgical treatment for unilateral hydronephrosis. The tissue-plasma ratio of contrast enhancement (TPR), which is an indicator of renal function per unit of parenchymal volume, improved after the operation. On the other hand, the renal parenchymal volume (PV) decreased in proportion to the shrinkage of the kidney. The pre and postoperative values of renal functional index (RFI), the product of the TPR and PV, showed a good correlation (r=0.928, p<0.01). Therefore, RFI values were found to be useful for assessing the recovery of hydronephrosis. (author)

  13. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  14. Geometric morphometric analysis of intratrackway variability: a case study on theropod and ornithopod dinosaur trackways from Münchehagen (Lower Cretaceous, Germany

    Directory of Open Access Journals (Sweden)

    Jens N. Lallensack

    2016-06-01

    Full Text Available A profound understanding of the influence of trackmaker anatomy, foot movements and substrate properties is crucial for any interpretation of fossil tracks. In this case study we analyze variability of footprint shape within one large theropod (T3, one medium-sized theropod (T2 and one ornithopod (I1 trackway from the Lower Cretaceous of Münchehagen (Lower Saxony, Germany in order to determine the informativeness of individual features and measurements for ichnotaxonomy, trackmaker identification, and the discrimination between left and right footprints. Landmark analysis is employed based on interpretative outline drawings derived from photogrammetric data, allowing for the location of variability within the footprint and the assessment of covariation of separate footprint parts. Objective methods to define the margins of a footprint are tested and shown to be sufficiently accurate to reproduce the most important results. The lateral hypex and the heel are the most variable regions in the two theropod trackways. As indicated by principal component analysis, a posterior shift of the lateral hypex is correlated with an anterior shift of the margin of the heel. This pattern is less pronounced in the ornithopod trackway, indicating that variation patterns can differ in separate trackways. In all trackways, hypices vary independently from each other, suggesting that their relative position a questionable feature for ichnotaxonomic purposes. Most criteria commonly employed to differentiate between left and right footprints assigned to theropods are found to be reasonably reliable. The described ornithopod footprints are asymmetrical, again allowing for a left–right differentiation. Strikingly, 12 out of 19 measured footprints of the T2 trackway are stepped over the trackway midline, rendering the trackway pattern a misleading left–right criterion for this trackway. Traditional measurements were unable to differentiate between the theropod and

  15. Geometric morphometric analysis of intratrackway variability: a case study on theropod and ornithopod dinosaur trackways from Münchehagen (Lower Cretaceous, Germany).

    Science.gov (United States)

    Lallensack, Jens N; van Heteren, Anneke H; Wings, Oliver

    2016-01-01

    A profound understanding of the influence of trackmaker anatomy, foot movements and substrate properties is crucial for any interpretation of fossil tracks. In this case study we analyze variability of footprint shape within one large theropod (T3), one medium-sized theropod (T2) and one ornithopod (I1) trackway from the Lower Cretaceous of Münchehagen (Lower Saxony, Germany) in order to determine the informativeness of individual features and measurements for ichnotaxonomy, trackmaker identification, and the discrimination between left and right footprints. Landmark analysis is employed based on interpretative outline drawings derived from photogrammetric data, allowing for the location of variability within the footprint and the assessment of covariation of separate footprint parts. Objective methods to define the margins of a footprint are tested and shown to be sufficiently accurate to reproduce the most important results. The lateral hypex and the heel are the most variable regions in the two theropod trackways. As indicated by principal component analysis, a posterior shift of the lateral hypex is correlated with an anterior shift of the margin of the heel. This pattern is less pronounced in the ornithopod trackway, indicating that variation patterns can differ in separate trackways. In all trackways, hypices vary independently from each other, suggesting that their relative position a questionable feature for ichnotaxonomic purposes. Most criteria commonly employed to differentiate between left and right footprints assigned to theropods are found to be reasonably reliable. The described ornithopod footprints are asymmetrical, again allowing for a left-right differentiation. Strikingly, 12 out of 19 measured footprints of the T2 trackway are stepped over the trackway midline, rendering the trackway pattern a misleading left-right criterion for this trackway. Traditional measurements were unable to differentiate between the theropod and the ornithopod

  16. Morphometric analysis of landslide in the Mountain Region of the State of Rio de Janeiro in Brazi: the case study of D'anta's watershed

    Science.gov (United States)

    Carvalho Araújo, João Paulo; da Silva, Lúcia Maria; Avear, Marcello; Dourado, Francisco; Ferreira Fernandes, Nelson

    2013-04-01

    Mass movements are recurrent phenomena in the whole Mountain Region of the State of Rio de Janeiro in Brazil. These events actively participate in the relief evolution and are also responsible for many damages and loss of human lives. The triggering of these events depends on the natural environment and the preparatory and immediate action of the physical, biotic and human agents responsible for these processes. This work is based on the hypothesis in which the topographical conditions have a major effect on the spatial distribution of translational landslides caused by decreased of the internal resistance of the material mobilized. Therefore, the purpose of this study is to identify the topographical conditions favorable to landslide triggering based on morphometric analysis in a pilot watershed - D'antás watershed - located in the mountainous region of the State of Rio de Janeiro. The indices include the topographic wetness index (TWI), contributing area, slope angle and elevation and were derived from 5-m grid digital terrain model, computed on a Geographic Information System (GIS). The maps produced allowed the analysis of topographic influence on the landslides distribution from the indices of frequency classes (F), concentration of scars (CC) and potential of landslide (PL). The landscape sectors that are more likely to be affected by landslides were the ones where the elevation ranges from 1070m - 1187m, slope angle between 40.95° and 47.77°, contributing area between (log10) 1.32 m² - 1.95 m² and topographic wetness index between 7.11 to 9.59. This work provides important information which may help in the decision-making process, using fewer data and indices of easy application. Finally, the results obtained will subsidize of a landslide susceptibility map through the implementation of the conditional probability method aimed at predicting and mitigating of the damage caused by landslides.

  17. Automated Morphological and Morphometric Analysis of Mass Spectrometry Imaging Data: Application to Biomarker Discovery

    Science.gov (United States)

    Picard de Muller, Gaël; Ait-Belkacem, Rima; Bonnel, David; Longuespée, Rémi; Stauber, Jonathan

    2017-12-01

    Mass spectrometry imaging datasets are mostly analyzed in terms of average intensity in regions of interest. However, biological tissues have different morphologies with several sizes, shapes, and structures. The important biological information, contained in this highly heterogeneous cellular organization, could be hidden by analyzing the average intensities. Finding an analytical process of morphology would help to find such information, describe tissue model, and support identification of biomarkers. This study describes an informatics approach for the extraction and identification of mass spectrometry image features and its application to sample analysis and modeling. For the proof of concept, two different tissue types (healthy kidney and CT-26 xenograft tumor tissues) were imaged and analyzed. A mouse kidney model and tumor model were generated using morphometric - number of objects and total surface - information. The morphometric information was used to identify m/z that have a heterogeneous distribution. It seems to be a worthwhile pursuit as clonal heterogeneity in a tumor is of clinical relevance. This study provides a new approach to find biomarker or support tissue classification with more information. [Figure not available: see fulltext.

  18. Intestinal morphometric and biomechanical changes during aging in rats

    DEFF Research Database (Denmark)

    Zhao, Jingbo; Gregersen, Hans

    2015-01-01

    Background and aim: Previously we demonstrated pronounced morphometric and biomechanical remodeling in the rat intestine during physiological growth up to 32 weeks of age. The aim of the present study is to study intestinal geometric and biomechanical changes in aging rats. Materials and methods...... in the circumferential direction. In conclusion pronounced morphometric and biomechanical remodeling occurred in the rat intestine during aging. The observed changes likely reflect the changes of the physiological function of the intestine during ageing, similar to other tissues where function, mechanical loading......: Twenty-four male Wistar rats, aged from 6 to 22 months, were used in the study. The body weight and the wet weight per length of duodenal and ileal segments were measured at the termination of experiment. Morphometric data were obtained by measuring the wall thickness and wall cross-sectional area...

  19. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  20. Establishing some Correlations between Certain Morphometric Parameters and Embryo Quality

    Directory of Open Access Journals (Sweden)

    Nicolae Păcală

    2011-05-01

    Full Text Available The aim of this paper was to establish some correlations between certain morphometric parameters and embryo quality. The morphometric parameters taken into consideration were: zona pellucida thickness, outer and inner diameter, and outer and inner perimeter. For experiments we used embryos recovered at 24 hours from mouse females superovulated with gonadotrope hormones (eCG and hCG. The embryos recovered were cultivated in KSOM media, supplemented with amino acids, and during the in vitro cultivation they were measured at different time intervals for establishing morphometric parameters. The data obtained were statistically analyzed using Minitab 15, using Fitted Line Plot regression that allows testing of the linear and polynomial regression of one variable. After statistical analyze of the data we found that the thickness of the zona pellucida can constitute a morphometric parameter that can be used as an indicator of subsequent development of the 2 cell embryos to morula and blastocyst stage respectively. The other morphometric parameters studied (outer and inner diameter, and outer and inner perimeter cannot be used as indicators of the embryo development.

  1. Morphometric analysis of llama (Lama glama) sperm head.

    Science.gov (United States)

    Casaretto, C; Lombardo, D M; Giuliano, S; Gambarotta, M; Carretero, M I; Miragaya, M H

    2012-05-01

    Llama production in Argentina has increased, as the international interest in breeding this type of animals has grown in the last years. Considering the great polymorphism that llama spermatozoa present at evaluation using light microscopy, the aim of this study was to objectively evaluate llama sperm head morphometry using digital morphometric analysis. Five ejaculates from each of eight males were obtained to evaluate morphometric parameters of 8000 sperm heads stained with Tinción 15(®). The following average results were obtained for each parameter: size parameters: area 20.09 μm(2), length 6.60 μm, width 4.14 μm, equivalent circle diameter 5.06 μm, curve length 5.79 μm and curve width 3.48 μm; boundary parameters: perimeter 18.54 μm and convex perimeter 17.34 μm; and shape parameters: roundness 1.28 and elongation 1.59. Morphometric parameters of sperm head were compared between ejaculates of the same male and between males. Significant differences between ejaculates of the same male were found for all parameters evaluated (P < 0.01). Significant differences between males were found for all morphometric parameters (P < 0.01) except for curve length, curve width and perimeter. The differences detected would indicate that there is not a single morphometric pattern for Lama glama sperm head, because parameter values cannot be standardised. © 2011 Blackwell Verlag GmbH.

  2. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    Energy Technology Data Exchange (ETDEWEB)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Patrie, James T.; Xin, Wenjun [University of Virginia, Department of Public Health Sciences, Charlottesville, VA (United States); Wintermark, Max [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Centre Hospitalier Universitaire Vaudois, Department of Radiology, Lausanne (Switzerland)

    2014-03-15

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI{sub vol}), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI{sub vol} and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  3. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    International Nuclear Information System (INIS)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah; Patrie, James T.; Xin, Wenjun; Wintermark, Max

    2014-01-01

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI vol ), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI vol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  4. CT studies in hyperprolactinemia; Badania KT w hiperprolaktynemii

    Energy Technology Data Exchange (ETDEWEB)

    Gradzki, J.; Paprzycki, W.; Krzyzagorska, E.; Wasko, R.; Warenik-Szymankiewicz, A. [Akademia Medyczna, Poznan (Poland)

    1993-12-31

    Computerized tomography studies in 62 patients (55 females and 7 males) with hyperprolactinemia are presented. The female patients had secondary amenorrhea and galactorrhea, whereas the male patients suffered from impotency, gynaecomastia and very rarely galactorrhea. In 39 cases CT revealed a pituitary adenoma (prolactinoma), in 14 cases of them microadenoma, as the cause of hormonal and clinical disturbances. In 21 cases an empty sella with rudimentary pituitary surrounded by cerebrospinal fluid or lack of pituitary mass were found. In one case suprasellar and intrasellar calcifications were present. (author). 17 refs, 4 figs.

  5. CT studies in hyperprolactinemia; Badania KT w hiperprolaktynemii

    Energy Technology Data Exchange (ETDEWEB)

    Gradzki, J; Paprzycki, W; Krzyzagorska, E; Wasko, R; Warenik-Szymankiewicz, A [Akademia Medyczna, Poznan (Poland)

    1994-12-31

    Computerized tomography studies in 62 patients (55 females and 7 males) with hyperprolactinemia are presented. The female patients had secondary amenorrhea and galactorrhea, whereas the male patients suffered from impotency, gynaecomastia and very rarely galactorrhea. In 39 cases CT revealed a pituitary adenoma (prolactinoma), in 14 cases of them microadenoma, as the cause of hormonal and clinical disturbances. In 21 cases an empty sella with rudimentary pituitary surrounded by cerebrospinal fluid or lack of pituitary mass were found. In one case suprasellar and intrasellar calcifications were present. (author). 17 refs, 4 figs.

  6. Renal functional CT studies of patients with nephrolithotomy

    International Nuclear Information System (INIS)

    Yokoyama, Masayoshi; Fujita, Kiyoshi; Watanabe, Kiyotaka; Ochi, Kenji; Takeuchi, Masafumi

    1985-01-01

    Renal functions of 13 patients, who underwent nephrolithotomy, were examined by the functional CT study. The warm ischemic time was 41+/-10 (mean+/-SD). After the operation, the tissueplasma ratio of contrast enhancement values failed to improve satisfactorily compared to that of the nonischemic hydronephrosis patients. Parenchymal volume decreased as much as that in the non-ischemic patients. As a result, Renal Functional Index (RFI) decreased significantly after nephrolithotomy. As RFI does not usually change in non-ischemic hydronephrosis after release of obstruction, the postischemic decrease of RFI may be caused mainly by ischemic damage and the effects of parechymal incision may not be dominant. (author)

  7. Study on the brain CT scan of SLE patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S; Narita, M; Katoh, K; Matsunaga, K; Ishigatsubo, Y [Yokohama City Univ. (Japan). Faculty of Medicine

    1982-03-01

    Cranial CT scanning revealed abnormality in 12 of 25 patients with SLE (48%). Ventricular sulcal enlargement was found mostly in younger patients between 16 and 36 years, an average of 25 years. Abnormality in electroencephalogram, principally paroxysmal abnormality, was found in 8 of 13 cases (62%) of normal CT findings. Non-paroxysmal slow-wave abnormality was observed in 9 of 12 abnormal CT cases. Of 13 patients with CNS symptoms, 8 had abnormal CT findings, and 5 had only mental disorder with normal CT findings. In 12 patients without neuropsychiatric involvement, 4 (33%) had abnormal CT findings. The rate of abnormal CT findings was increased in the patients receiving a high dosage of a steroid agent. Five of 6 patients who showed ventricular sulcal enlargement had been given prednisolone in a dosage of 35 mg or more per day.

  8. Renal Artery Variations, Hilar Arrangement and Its Distances to Ventral Branches of Abdominal Aorta: A Morphometric Study

    Directory of Open Access Journals (Sweden)

    D'Souza A

    2015-10-01

    Full Text Available Purpose: To measure the distance of origin of renal artery in relation to the ventral branches of abdominal aorta and also to study the variations in the number and the hilar branching pattern of renal arteries. Materials and methods: The present study was carried out using ten embalmed adult cadavers. The distances were measured bilaterally from the origin of renal artery to the origin of superior and inferior mesenteric artery and the bifurcation of abdominal aorta. Results: Out of ten cadavers studied, bilateral accessory renal artery was observed in two cases. The hilar branching pattern varied from a single artery to maximum of six branches. The mean and standard deviations of the measured parameters were calculated. Conclusion: Knowledge of variations of renal artery is important for surgeons in performing many procedures and may help to avoid clinical complications in the abdominal region.

  9. The effect of morphometric atlas selection on multi-atlas-based automatic brachial plexus segmentation

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Wouters, Johan; Vercauteren, Tom; De Gersem, Werner; Achten, Eric; De Neve, Wilfried; Van Hoof, Tom

    2015-01-01

    The present study aimed to measure the effect of a morphometric atlas selection strategy on the accuracy of multi-atlas-based BP autosegmentation using the commercially available software package ADMIRE® and to determine the optimal number of selected atlases to use. Autosegmentation accuracy was measured by comparing all generated automatic BP segmentations with anatomically validated gold standard segmentations that were developed using cadavers. Twelve cadaver computed tomography (CT) atlases were included in the study. One atlas was selected as a patient in ADMIRE®, and multi-atlas-based BP autosegmentation was first performed with a group of morphometrically preselected atlases. In this group, the atlases were selected on the basis of similarity in the shoulder protraction position with the patient. The number of selected atlases used started at two and increased up to eight. Subsequently, a group of randomly chosen, non-selected atlases were taken. In this second group, every possible combination of 2 to 8 random atlases was used for multi-atlas-based BP autosegmentation. For both groups, the average Dice similarity coefficient (DSC), Jaccard index (JI) and Inclusion index (INI) were calculated, measuring the similarity of the generated automatic BP segmentations and the gold standard segmentation. Similarity indices of both groups were compared using an independent sample t-test, and the optimal number of selected atlases was investigated using an equivalence trial. For each number of atlases, average similarity indices of the morphometrically selected atlas group were significantly higher than the random group (p < 0,05). In this study, the highest similarity indices were achieved using multi-atlas autosegmentation with 6 selected atlases (average DSC = 0,598; average JI = 0,434; average INI = 0,733). Morphometric atlas selection on the basis of the protraction position of the patient significantly improves multi-atlas-based BP autosegmentation accuracy

  10. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  11. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  12. Effects of intraoperative irradiation (IORT) and intraoperative hyperthermia (IOHT) on canine sciatic nerve : Histopathological and morphometric studies

    NARCIS (Netherlands)

    Vujaskovic, Z; Powers, BE; Paardekoper, G; Gillette, SM; Gillette, EL; Colacchio, TA

    1999-01-01

    Purpose/Objective: Peripheral neuropathies have emerged as the major dose-limiting complication reported after intraoperative radiation therapy (IORT). The combination of IORT with hyperthermia may further increase the risk of peripheral nerve injury. The objective of this study was to evaluate

  13. Restraint of appetite and reduced regional brain volumes in anorexia nervosa: a voxel-based morphometric study

    Directory of Open Access Journals (Sweden)

    Brooks Samantha J

    2011-11-01

    Full Text Available Abstract Background Previous Magnetic Resonance Imaging (MRI studies of people with anorexia nervosa (AN have shown differences in brain structure. This study aimed to provide preliminary extensions of this data by examining how different levels of appetitive restraint impact on brain volume. Methods Voxel based morphometry (VBM, corrected for total intracranial volume, age, BMI, years of education in 14 women with AN (8 RAN and 6 BPAN and 21 women (HC was performed. Correlations between brain volume and dietary restraint were done using Statistical Package for the Social Sciences (SPSS. Results Increased right dorsolateral prefrontal cortex (DLPFC and reduced right anterior insular cortex, bilateral parahippocampal gyrus, left fusiform gyrus, left cerebellum and right posterior cingulate volumes in AN compared to HC. RAN compared to BPAN had reduced left orbitofrontal cortex, right anterior insular cortex, bilateral parahippocampal gyrus and left cerebellum. Age negatively correlated with right DLPFC volume in HC but not in AN; dietary restraint and BMI predicted 57% of variance in right DLPFC volume in AN. Conclusions In AN, brain volume differences were found in appetitive, somatosensory and top-down control brain regions. Differences in regional GMV may be linked to levels of appetitive restraint, but whether they are state or trait is unclear. Nevertheless, these discrete brain volume differences provide candidate brain regions for further structural and functional study in people with eating disorders.

  14. Morphometric analysis of pulp size in maxillary permanent central incisors correlated with age: An indirect digital study.

    Science.gov (United States)

    Ravindra, S V; Mamatha, G P; Sunita, J D; Balappanavar, Aswini Y; Sardana, Varun

    2015-01-01

    Teeth are hardest part of the body and are least affected by the taphonomic process. They are considered as one of the reliable methods of identification of a person in forensic sciences. The aim of the following study is to establish morphometeric measurements by AutoCad 2009 (Autodesk, Inc) of permanent maxillary central incisors in different age groups of Udaipur population. Hospital-based descriptive cross-sectional study carried out in Udaipur. A study was carried out on 308 subjects of both genders with the age range of 9-68 years. Standardized intra-oral radiographs were made by paralleling technique and processed. The radiographs were scanned and the obtained images were standardized to the actual size of radiographic film. This was followed by measuring them using software AutoCad 2009. F-test, post-hoc test, Pearson's correlation test. For left maxillary central incisor, the total pulp area was found to be of 38.41 ± 12.88 mm and 14.32 ± 7.04 mm respectively. For right maxillary central incisor, the total pulp size was 38.39 ± 14.95 mm and 12.35 ± 5 mm respectively. Males (32.50, 32.87 mm(2)) had more pulp area when compared with females (28.82, 30.05 mm(2)). There was a decrease in total pulp area with increasing age which may be attributed to secondary dentin formation.

  15. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  16. S100B-immunopositive glia is elevated in paranoid as compared to residual schizophrenia: a morphometric study.

    Science.gov (United States)

    Steiner, Johann; Bernstein, Hans-Gert; Bielau, Hendrik; Farkas, Nadine; Winter, Jana; Dobrowolny, Henrik; Brisch, Ralf; Gos, Tomasz; Mawrin, Christian; Myint, Aye Mu; Bogerts, Bernhard

    2008-08-01

    Several studies have revealed increased S100B levels in peripheral blood and cerebrospinal fluid (CSF) of patients with schizophrenia. In this context, it was postulated that elevated levels of S100B may indicate changes of pathophysiological significance to brain tissue in general and astrocytes in particular. However, no histological study has been published on the cellular distribution of S100B in the brain of individuals with schizophrenia to clarify this hypothesis. The cell-density of S100B-immunopositive glia was analyzed in the anterior cingulate, dorsolateral prefrontal (DLPF), orbitofrontal, and superior temporal cortices/adjacent white matter, pyramidal layer/alveus of the hippocampus, and the mediodorsal thalamic nucleus of 18 patients with schizophrenia and 16 matched control subjects. Cortical brain regions contained more S100B-immunopositive glia in the schizophrenia group relative to controls (P=0.046). This effect was caused by the paranoid schizophrenia subgroup (P=0.018). Separate analysis of white matter revealed no diagnostic main group effect (P=0.846). However, the white matter of patients with paranoid schizophrenia contained more (mainly oligodendrocytic) S100B-positive glia as compared to residual schizophrenia (P=0.021). These effects were particularly pronounced in the DLPF brain area. Our study reveals distinct histological patterns of S100B immunoeactive glia in two schizophrenia subtypes. This may be indicative of a heterogenic pathophysiology or distinct compensatory abilities: Astro-/oligodendroglial activation may result in increased cellular S100B in paranoid schizophrenia. On the contrary, residual schizophrenia may be caused by white matter oligodendroglial damage or dysfunction, associated with a release of S100B into body fluids.

  17. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-12-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: (1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. (2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. (3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis.

  18. Postoperative follow-up study of craniosynostosis using three-dimensional surface reconstruction CT (3D-CT)

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Tsukiyama, Takashi; Nishimura, Jiro; Fujioka, Mutsuhisa; Tsubokawa, Takashi.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three-dimensional images from high-resolution CT-scan series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephalocele, and other skeletal pathologies. In this study, the postoperative assessment of craniofacial surgical results has been accomplished using 3D-CT techniques in craniosynostosis. The results are as follows: 1) Postoperative 3D-CTs reveal the bony anatomical details corrected by the craniofacial surgery more precisely and more stereographically than do conventional radiological techniques. 2) Secondary changes in the cranium after the surgery, such as reossification at the area of osteotomies or postoperative asymmetric skull deformities, are more early detected by the 3D-CT imaging technique than by a craniogram. 3) In 3D-CT images, internal views of the skull, such mid-sagittal, rear internal, or top axial views of the intracranial skull base, are most useful in postoperative assessments of the surgical results and of postoperative secondary changes in the cranium. Based on our experience, we expect that 3D-CT imaging techniques will become more important in the management of craniosynostosis. (author)

  19. Morphometric study of the true S1 and S2 of the normal and dysmorphic sacralized sacra.

    Science.gov (United States)

    Firat, Ayşegül; Alemdaroğlu, Kadir Bahadır; Özmeriç, Ahmet; Yücens, Mehmet; Göksülük, Dinçer

    2017-06-12

    This study aimed to generate data for the S1 and S2 alar pedicle and body and the alar orientations for both dysmorphic and normal sacra. The study comprised two groups: Group N consisted of 53 normal sacra and Group D included 10 dysmorphic sacra. Various features such as alar pedicle circumference; anterior, middle, and posterior axis of the sacral ala; sacral body height and width; and sagittal thickness were measured. In group N, the median anterior axis of the alae was observed to be 30° on the right and 25° on the left, the median midline axis was found to be 20° on the right and 15° on the left, and the median posterior alar axis was -15° on the right and -20° on the left. The true S1 and S2 alar pedicle circumferences were observed to be significantly smaller in group D, which demonstrated a shorter S1 alar pedicle mean circumference, significantly narrower S1 body mean width, and considerably tapered sagittal thickness. Our analysis indicated that dysmorphic sacra have a lower sagittal thickness and width of bodies and smaller alar pedicles, which explains the difficulties in their percutaneous fixation.

  20. Lipid metabolism abnormalities in alcohol-treated rabbits: a morphometric and haematologic study comparing high and low alcohol doses.

    Science.gov (United States)

    Ikemura, Satoshi; Yamamoto, Takuaki; Motomura, Goro; Iwasaki, Kenyu; Yamaguchi, Ryosuke; Zhao, Garida; Iwamoto, Yukihide

    2011-08-01

    The pathogenesis of alcohol-induced osteonecrosis remains unclear. The purpose of the present study was to evaluate the morphological changes in bone marrow fat cells and the changes in the serum lipid levels in alcohol-treated rabbits. Fifteen rabbits were randomly assigned into three groups: Four rabbits intragastrically received low-dose alcohol (LDA) (15 ml/kg per day) containing 15% ethanol for 4 weeks, five rabbits received high-dose alcohol (HDA) (30 ml/kg per day) for 4 weeks and six rabbits received physiologic saline for 4 weeks as a control group. Six weeks after the initial alcohol administration, all rabbits were sacrificed. The mean size of the bone marrow fat cells in rabbits treated with HDA was significantly larger than that in the control group (P = 0.0001). Haematologically, the levels of triglycerides and free fatty acids in the rabbits treated with both low-dose and HDA were significantly higher than those in the control group (P = 0.001 for both comparisons). The results of this study are that there are lipid metabolism abnormalities, both morphologically and haematologically, after alcohol administration. Also these findings were more apparent in rabbits treated with HDA than those treated with LDA. © 2011 The Authors. International Journal of Experimental Pathology © 2011 International Journal of Experimental Pathology.

  1. Comparative morphometrical and histological study of lingual papillae in two different ages of the Iraqi buffalo (Bubalus bubalis

    Directory of Open Access Journals (Sweden)

    A.A. Hasso

    2015-06-01

    Full Text Available Twenty two tongues of buffalo collected from the slaughter house of Mousl city (11 tongues for adult animals 3-4 years and11tongues for small ages 1 weake-2 monthes. Two groups were used in this study, twelve samples for anatomical study and ten samples for histological study, in each group of this study, the tongues were divided into four regions from apex to the end of the root. The tongue is a muscular organ which consists of dorsal and ventral surfaces, it is formed from three parts (apex, body and root. The lingual fossa and torus linguae both appear on the dorsal surface. The total average of the tongue length in adult animals (36.00±0.97 cm while the highest average of the length, width and thickness found in the third region. The total length in small ages was (16.92±0.98 cm and the highest average of length and thickness again it happens in third region and the highest width in this age group found in the second region. The investigation of the normal anatomical structures of the tongue distinguished four lingual papillae (filiform, fungiform, conical and circumvalate while the lenticuler papillae absent in both age groups. The filiform and fungiform papillae spread over the dorsal surface and ventro-lateral surface terminat abruptly at the ventro-lateral border forming a distinct straight line from apex to the torus linguae in both ages. The present work reveals that the highest average of filiform papillae in both surface (dorsal and ventro-lateral surface founds in second region in adult group, while in small group founds in first region. The highest average of fungiform papillae in both surface of both age groups are in the apex of tongue. The highest average of conical and circumvalate papillae in both age group (adult and young were on torus linguae. The histological study has been used the shape, diameter and the type of epithelium which covered the papillae in both groups. The filiform papillae are long fine projection beading

  2. Anatomic Correlation of the Mini-Mental State Examination: A Voxel-Based Morphometric Study in Older Adults.

    Science.gov (United States)

    Dinomais, Mickael; Celle, Sebastien; Duval, Guillaume T; Roche, Frederic; Henni, Samir; Bartha, Robert; Beauchet, Olivier; Annweiler, Cedric

    2016-01-01

    The clinical utility of the Mini-Mental State Examination (MMSE) and its shorter version (SMMSE) is still debated. There is a need to better understand the neuroanatomical correlates of these cognitive tests. The objective of this cross-sectional study was to determine whether lower MMSE and SMMSE scores correlated with focal brain volume reduction in older adults. Participants from the GAIT study (n = 207; mean, 70.9±5.9 years; 57% female; mean MMSE 26.2±3.9; mean SMMSE 5.1±1.1) were evaluated using the MMSE and SMMSE and received a 1.5-Tesla MRI scan of the brain. Cortical gray and white matter subvolumes were automatically segmented using Statistical Parametric Mapping. Age, gender, education level, and total intracranial volume were included as potential confounders. We found correlations between the MMSE score and specific cortical regions of the limbic system including the hippocampus, amygdala, cingulate gyrus, and parahippocampal gyrus, independently of the diagnostic category (i.e., mild cognitive impairment or Alzheimer disease or controls). Regarding correlations with the SMMSE score, only one cluster in the left hippocampus was identified, which overlapped with the cluster that was positively correlated with the MMSE score. There were no correlations with the volume of white matter. In conclusion, worse MMSE and SMMSE scores were associated with gray matter atrophy mainly in the limbic system. This finding highlights that atrophy of specific brain regions are related to performance on the MMSE and the SMMSE tests, and provides new insights into the cognitive function probed by these tests.

  3. Comparative effects of riboflavin, nicotinamide and folic acid on alveolar bone loss: A morphometric and histopathologic study in rats

    Directory of Open Access Journals (Sweden)

    Akpınar Aysun

    2016-01-01

    Full Text Available Introduction. Periodontitis is a chronic inflammatory and osteolytic disease. Vitamin B complex is a class of water-soluble vitamins that play important roles in cell metabolism. Objective. The aim of this study was to evaluate the effects of riboflavin (RBF, nicotinamide (NA, and folic acid (FA on alveolar bone loss in experimental periodontitis rat model. Methods. Sixty-four male Wistar rats were randomly divided into the following eight groups: Control, Ligated, RBF50 (RBF, 50 mg/kg daily, NA50 (NA, 50 mg/kg daily, FA50 (FA, 50 mg/kg daily, RBF100 (RBF, 100 mg/kg daily, NA100 (NA, 100 mg/kg daily, and FA100 (FA, 100 mg/kg daily. Periodontitis was induced using silk ligature around the right first mandibular molar. After 11 days the rats were sacrificed. Mandible and serum samples were collected. Changes in alveolar bone levels were measured clinically, and periodontal tissues were examined histopathologically. Serum IL-1β (pg/ml levels were analyzed by using ELISA. Results. Mean alveolar bone loss in the mandibular first molar tooth revealed to be significantly lower in RBF100 group than in the Control group. In the Ligated group, alveolar bone loss was significantly higher than in all other groups. The ratio of presence of inflammatory cell infiltration in the Ligated group was significantly higher than in the Control group. The differences in the serum IL-1β levels between the groups were not statistically significant. Osteoclasts that were observed in the Ligated group were significantly higher than those of the Control and FA100 groups. The osteoblastic activity in the Ligated group, RBF100, and NA100 groups were shown to be significantly higher than those in the Control group. Conclusion. This study has demonstrated that systemic administration of RBF, NA, and FA in different dosages (50-100 mg/kg reduced alveolar bone loss in periodontal disease in rats.

  4. A pilot study of morphometric analysis of choroidal vasculature in vivo, using en face optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Mahsa Sohrab

    Full Text Available To study the ability of volumetric spectral domain optical coherence tomography (SD-OCT to perform quantitative measurement of the choroidal vasculature in vivo.Choroidal vascular density and vessel size were quantified using en face choroidal scans from various depths below the retinal pigment epithelium (RPE in 58 eyes of 58 patients with either epiretinal membranes (ERM, early age-related macular degeneration (AMD, or reticular pseudo-drusen (RPD. For each patient, we used the macular volume scan (6×6 mm cube for vessel quantification, while high-definition (HD cross-section raster scans were used to qualitatively assess vascularity of the choroidal sub-layers, and measure choroidal thickness.Of the 58 patients, more were female (66% versus 34% male, of whom 14 (24% had ERM, 11 (19% early AMD, and 33 (57% RPD. Compared to intact choriocapillaris in all ERM (100%, none of the RPD and only 5/11 (45% early AMD eyes had visible choriocapillaris on either cross section or C-scans (p-value<0.001. When comparing select regions from the most superficial C-scans, early AMD group had lowest vascular density and RPD had highest (p-value 0.04. Qualitative evaluation of C-scans from all three groups revealed a more granular appearance of the choriocapillaris in ERM versus increased stroma and larger vessels in the RPD eyes.SD-OCT can be used to qualitatively and quantitatively assess choroidal vascularity in vivo. Our findings correlate to previously reported histopathologic studies. Lack of choriocapillaris on HD cross-sections or C-scans in all RPD and about half of early AMD eyes suggests earlier choroidal involvement in AMD and specifically, RPD.

  5. Effect of visual experience on structural organization of the human brain: A voxel based morphometric study using DARTEL

    International Nuclear Information System (INIS)

    Modi, Shilpi; Bhattacharya, Manisha; Singh, Namita; Tripathi, Rajendra Prasad; Khushu, Subash

    2012-01-01

    Objective: To investigate structural reorganization in the brain with differential visual experience using Voxel-Based Morphometry with Diffeomorphic Anatomic Registration Through Exponentiated Lie algebra algorithm (DARTEL) approach. Materials and methods: High resolution structural MR images were taken in fifteen normal sighted healthy controls, thirteen totally blind subjects and six partial blind subjects. The analysis was carried out using SPM8 software on MATLAB 7.6.0 platform. Results: VBM study revealed gray matter volume atrophy in the cerebellum and left inferior parietal cortex in total blind subjects and in left inferior parietal cortex, right caudate nucleus, and left primary visual cortex in partial blind subjects as compared to controls. White matter volume loss was found in calcarine gyrus in total blind subjects and Thlamus-somatosensory region in partially blind subjects as compared to controls. Besides, an increase in Gray Matter volume was also found in left middle occipital and middle frontal gyrus and right entorhinal cortex, and an increase in White Matter volume was found in superior frontal gyrus, left middle temporal gyrus and right Heschl's gyrus in totally blind subjects as compared to controls. Comparison between total and partial blind subjects revealed a greater Gray Matter volume in left cerebellum of partial blinds and left Brodmann area 18 of total blind subjects. Conclusion: Results suggest that, loss of vision at an early age can induce significant structural reorganization on account of the loss of visual input. These plastic changes are different in early onset of total blindness as compared to partial blindness

  6. Bone Morphometric Evaluation around Immediately Placed Implants Covered with Porcine-Derived Pericardium Membrane: An Experimental Study in Dogs

    Directory of Open Access Journals (Sweden)

    Ryo Jimbo

    2012-01-01

    Full Text Available Objective. To investigate whether porcine-derived bioresorbable pericardium membrane coverage enhances the osseointegration around implants placed in fresh extraction sockets. Study Design. Twenty-four commercially available endosseous implants were placed in the fresh extraction sockets of the mandibular first molar of mature beagles (. On one side, implants and osteotomy sites were covered with porcine-derived bioresorbable pericardium membranes, whereas on the other side, no membranes were used. After 6 weeks, samples were retrieved and were histologically processed for histomorphometric analysis. Results. The histological observation showed that bone loss and soft tissue migration in the coronal region of the implant were evident for the control group, whereas bone fill was evident up to the neck of the implant for the membrane-covered group. Bone-to-implant contact was significantly higher for the membrane-covered group compared to the control group, 75% and 45% (, respectively. Conclusion. The experimental membranes proved to regenerate bone around implants placed in fresh extraction sockets without soft tissue intrusion.

  7. Regional Gray Matter Volumes Are Related to Concern About Falling in Older People: A Voxel-Based Morphometric Study.

    Science.gov (United States)

    Tuerk, Carola; Zhang, Haobo; Sachdev, Perminder; Lord, Stephen R; Brodaty, Henry; Wen, Wei; Delbaere, Kim

    2016-01-01

    Concern about falling is common in older people. Various related psychological constructs as well as poor balance and slow gait have been associated with decreased gray matter (GM) volume in old age. The current study investigates the association between concern about falling and voxel-wise GM volumes. A total of 281 community-dwelling older people aged 70-90 years underwent structural magnetic resonance imaging. Concern about falling was assessed using Falls Efficacy Scale-International (FES-I). For each participant, voxel-wise GM volumes were generated with voxel-based morphometry and regressed on raw FES-I scores (p fall risk did not alter these associations. After adjustment for anxiety, only left cerebellum and bilateral inferior occipital gyrus remained negatively associated with FES-I scores (voxels-in-cluster = 2,426; p falling is negatively associated with brain volumes in areas important for emotional control and for motor control, executive functions and visual processing in a large sample of older men and women. Regression analyses suggest that these relationships were primarily accounted for by psychological factors (generalized anxiety and neuroticism) and not by physical fall risk or vision. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. The use of texture analysis in the vertebral morphometric study of a lordotic chub (Squalius cephalus L.

    Directory of Open Access Journals (Sweden)

    Maurizio Manera

    2014-08-01

    Full Text Available Objective: To characterise vertebral aspects of a lordotic chub (Squalius cephalus L. using texture analysis by radiograph and to verify possible alterations in the vertebral microarchitecture of the lordotic tract. Methods: Four vertebrae belonging to the lordotic tract were analyzed for their texture features by means of a software package (MaZda vers. 4.6 and were compared, for the same features, to other four vertebrae cranial (anterior to the lordotic vertebrae. Results: Two representative features were selected out of 259 extracted texture features by means of the convex hull selection method. In particular, (5, 5 sum of squares (according to cooccurrence matrix method and 45° short run emphasis (according to run-length matrix method were used to classify, without classification errors, two selected spinal tracts (the lordotic one and the immediately cranial one, both corresponding to the anal fin pterigiophores vertebral portion according to the following methods: linear discriminant analysis and hierarchical clustering. Conclusions: This is the first known application of texture analysis in medical imaging applied to fish species and represents a start point for further studies in aquariology and in aquaculture, where spinal deformities occur relative frequently and are cause of economic losses.

  9. Effect of ligamenta flava hypertrophy on lumbar disc herniation with contralateral symptoms and signs: a clinical and morphometric study

    Science.gov (United States)

    Yildizhan, Ahmet; Atar, Elmas K.; Yaycioglu, Soner; Gocmen-Mas, Nuket; Yazici, Canan

    2010-01-01

    Introduction The purpose of this study was to determine whether ligamentum flavum hypertrophy among disc herniated patients causes contralateral pain symptoms. For this reason we measured the thickness of the ligament in disc herniated patients with ipsilateral or contralateral symptoms. Material and methods Two hundred disc herniated patients with ipsilateral symptoms as group I were compared with five disc herniated patients with only contralateral symptoms as group II. Ligamenta flava thicknesses and spinal canal diameters of both groups were measured on magnetic resonance imaging (MRI) with a micro-caliper. Results Both groups underwent surgery only on the disc herniated side. The total thicknesses of the ligamenta flava in group II was thicker than in group I. There was no spinal stenosis in either group and no significance difference between the groups. Statistically significant differences were found for both ipsilateral and contralateral thickness of the ligament flava in both groups. We also compared thickness of the ligamenta flava for each level of disc herniation in group I; ligamenta flava hypertrophy was more common at L3-L4 and L4-L5 levels of vertebrae in females. Conclusions Aetiology of contralateral sciatica among disc herniated patients may be related to hypertrophy of the ligamenta flava, especially on the opposite side. Surgical approaches of the disc herniated side alone may be sufficient for a good outcome. PMID:22371809

  10. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  11. Effect of visual experience on structural organization of the human brain: A voxel based morphometric study using DARTEL

    Energy Technology Data Exchange (ETDEWEB)

    Modi, Shilpi, E-mail: modi_shilpi@yahoo.co.in [NMR Research Centre, Institute of Nuclear Medicine and Allied Sciences (DRDO), Lucknow Road, Timarpur, Delhi (India); Bhattacharya, Manisha, E-mail: manishab10@gmail.com [NMR Research Centre, Institute of Nuclear Medicine and Allied Sciences (DRDO), Lucknow Road, Timarpur, Delhi (India); Singh, Namita, E-mail: namita23m@gmail.com [NMR Research Centre, Institute of Nuclear Medicine and Allied Sciences (DRDO), Lucknow Road, Timarpur, Delhi (India); Tripathi, Rajendra Prasad, E-mail: director@inmas.drdo.in [NMR Research Centre, Institute of Nuclear Medicine and Allied Sciences (DRDO), Lucknow Road, Timarpur, Delhi (India); Khushu, Subash, E-mail: skhushu@yahoo.com [NMR Research Centre, Institute of Nuclear Medicine and Allied Sciences (DRDO), Lucknow Road, Timarpur, Delhi (India)

    2012-10-15

    Objective: To investigate structural reorganization in the brain with differential visual experience using Voxel-Based Morphometry with Diffeomorphic Anatomic Registration Through Exponentiated Lie algebra algorithm (DARTEL) approach. Materials and methods: High resolution structural MR images were taken in fifteen normal sighted healthy controls, thirteen totally blind subjects and six partial blind subjects. The analysis was carried out using SPM8 software on MATLAB 7.6.0 platform. Results: VBM study revealed gray matter volume atrophy in the cerebellum and left inferior parietal cortex in total blind subjects and in left inferior parietal cortex, right caudate nucleus, and left primary visual cortex in partial blind subjects as compared to controls. White matter volume loss was found in calcarine gyrus in total blind subjects and Thlamus-somatosensory region in partially blind subjects as compared to controls. Besides, an increase in Gray Matter volume was also found in left middle occipital and middle frontal gyrus and right entorhinal cortex, and an increase in White Matter volume was found in superior frontal gyrus, left middle temporal gyrus and right Heschl's gyrus in totally blind subjects as compared to controls. Comparison between total and partial blind subjects revealed a greater Gray Matter volume in left cerebellum of partial blinds and left Brodmann area 18 of total blind subjects. Conclusion: Results suggest that, loss of vision at an early age can induce significant structural reorganization on account of the loss of visual input. These plastic changes are different in early onset of total blindness as compared to partial blindness.

  12. Effect of visual experience on structural organization of the human brain: a voxel based morphometric study using DARTEL.

    Science.gov (United States)

    Modi, Shilpi; Bhattacharya, Manisha; Singh, Namita; Tripathi, Rajendra Prasad; Khushu, Subash

    2012-10-01

    To investigate structural reorganization in the brain with differential visual experience using Voxel-Based Morphometry with Diffeomorphic Anatomic Registration Through Exponentiated Lie algebra algorithm (DARTEL) approach. High resolution structural MR images were taken in fifteen normal sighted healthy controls, thirteen totally blind subjects and six partial blind subjects. The analysis was carried out using SPM8 software on MATLAB 7.6.0 platform. VBM study revealed gray matter volume atrophy in the cerebellum and left inferior parietal cortex in total blind subjects and in left inferior parietal cortex, right caudate nucleus, and left primary visual cortex in partial blind subjects as compared to controls. White matter volume loss was found in calcarine gyrus in total blind subjects and Thlamus-somatosensory region in partially blind subjects as compared to controls. Besides, an increase in Gray Matter volume was also found in left middle occipital and middle frontal gyrus and right entorhinal cortex, and an increase in White Matter volume was found in superior frontal gyrus, left middle temporal gyrus and right Heschl's gyrus in totally blind subjects as compared to controls. Comparison between total and partial blind subjects revealed a greater Gray Matter volume in left cerebellum of partial blinds and left Brodmann area 18 of total blind subjects. Results suggest that, loss of vision at an early age can induce significant structural reorganization on account of the loss of visual input. These plastic changes are different in early onset of total blindness as compared to partial blindness. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Brain morphometric analysis predicts decline of intelligence quotient in children with sickle cell disease: A preliminary study.

    Science.gov (United States)

    Chen, Rong; Krejza, Jaroslaw; Arkuszewski, Michal; Zimmerman, Robert A; Herskovits, Edward H; Melhem, Elias R

    2017-03-01

    For children with sickle cell disease (SCD) and at low risk category of stroke, we aim to build a predictive model to differentiate those with decline of intelligence-quotient (IQ) from counterparts without decline, based on structural magnetic-resonance (MR) imaging volumetric analysis. This preliminary prospective cohort study included 25 children with SCD, homozygous for hemoglobin S, with no history of stroke and transcranial Doppler mean velocities below 170cm/s at baseline. We administered the Kaufman Brief Intelligence Test (K-BIT) to each child at yearly intervals for 2-4 years. Each child underwent MR examination within 30 days of the baseline K-BIT evaluation date. We calculated K-BIT change rates, and used rate of change in K-BIT to classify children into two groups: a decline group and a non-decline group. We then generated predictive models to predict K-BIT decline/non-decline based on regional gray-matter (GM) volumes computed from structural MR images. We identified six structures (the left median cingulate gyrus, the right middle occipital gyrus, the left inferior occipital gyrus, the right fusiform gyrus, the right middle temporal gyrus, the right inferior temporal gyrus) that, when assessed for volume at baseline, are jointly predictive of whether a child would suffer subsequent K-BIT decline. Based on these six regional GM volumes and the baseline K-BIT, we built a prognostic model using the K * algorithm. The accuracy, sensitivity and specificity were 0.84, 0.78 and 0.86, respectively. GM volumetric analysis predicts subsequent IQ decline for children with SCD. Copyright © 2017 Medical University of Bialystok. Published by Elsevier B.V. All rights reserved.

  14. A COMPARATIVE STUDY ON BODY MORPHOMETRIC, REPRODUCTIVE AND VITAL PARAMETERS AMONG INDIGENOUS GOAT POPULATION OF ODISHA, INDIA

    Directory of Open Access Journals (Sweden)

    Siddhant Sekhar Sahoo

    2018-06-01

    Full Text Available The importance of goat in Indian economy is inevitable. A study on phenotypic traits of goats will give a better insight to their individuality and potentiality for future improvement. Phenotypic data on goat from different agroclimatic zones of Odisha were collected and analysed. The least square means of height at wither, height at rump, heart girth, punch girth, neck girth, body length (60.78 ± 0.93, 64.04 ± 0.91, 60.21 ± 0.43, 65.71 ± 0.47, 35.20 ± 0.52, 54.81 ± 0.74 cm were found to be highest in Ganjam goat population followed by Koraput (Raighar and Black Bengal goat with significantly (p < 0.01 positive correlation. For reproductive traits, the least square means of litter size (2.36 ± 0.11, 1.57 ± 0.13, 1.75 ± 0.11 and kidding interval (6.63 ± 0.24, 10.93 ± 0.28, 8.62 ± 0.23 months for Black Bengal, Ganjam and Koraput (Raighar goat breeds differed significantly (p < 0.05. The least square means of rectal temperature and skin temperature were found to be higher in Ganjam goat (102.38 ± 0.07 ºF, 100.95 ± 0.07 ºF as compared to Koraput (Raighar (102.19 ± 0.08 ºF, 100.85 ± 0.07 ºF and Black Bengal goats (101.33 ± 0.10 ºF, 100.16 ± 0.11 ºF. But, the least square means of heart rate and respiration rate were found to be higher in Black Bengal goat (74.08 ± 1.61, 37.28 ± 1.06 as compared to Ganjam (72.47 ± 0.58, 31.35 ± 0.54 and Koraput (Raighar goats (70.54 ± 0.42, 26.73 ± 0.35.

  15. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  16. Studies on diagnosis of lung emphysema by CT image using experimental models and clinical cases

    International Nuclear Information System (INIS)

    Nakatani, Seiki

    1998-01-01

    Since the detailed report between the degree of functional disorder in lung emphysema and the analysis of CT image is quite unknown, the present study was attempted to produce the experimental model of lung emphysema with various stages by the administration of papain to the focal lobe in canine lung. Using this model or clinical lung emphysema, the relationship between the degree of destruction of alveolar walls, clinical pulmonary functions and CT images was investigated. CT scan was performed at the level of 50% vital capacity in both experimental models and clinical subjects by using spirometric gating CT. CT density histogram was obtained from CT image which was produced by using the developed software for this purpose. Densitometric parameters, such as mean CT value, %LAA, the peak in the histogram and 5% tile were selected from CT image. Papain solution of 5 mg/kg body weight was cumulatively administered to the left lower lobe in canine lung, resulting in the destruction of lung alveolar walls in parallel to the increasing dosage of papain. There was a significant correlation between not only the increasing dosage of papain, but also %FEV 1.0 and CT densitometric parameters, indicating that the histological changes of alveolar walls and the lung function in lung emphysema could be estimated by analysis of CT image. These experimental and clinical studies suggest that the analysis of CT image can reflect the pathophysiological changes in the lung and be useful for precise clinical diagnosis of lung emphysema. (author)

  17. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  18. Basic studies of CT in the maxillofacial areas, 1

    International Nuclear Information System (INIS)

    Suzuki, Shinichiro; Kaneko, Hiroshi; Higashi, Tomomitsu; Takenaka, Eiichi.

    1982-01-01

    As CT values of hard tissues would pose problems in the application of CT to the maxillofacial area, attenuation coefficients of each oral hard tissue were examined based on the existing data, and the linearity in the area of high x-ray attenuation was examined. We thought that a new contrast scale suitable for each area should be established for measurements of CT values of tissues of high x-ray attenuation such as teeth. (Chiba, N.)

  19. Estudio morfométrico de Quercus sartorii y Q. xalapensis (Fagaceae Morphometric study of Quercus sartorii and Q. xalapensis (Fagaceae

    Directory of Open Access Journals (Sweden)

    Dorismilda Martínez-Cabrera

    2011-06-01

    Full Text Available Se realizó un estudio morfométrico con la finalidad de contribuir en la delimitación taxonómica de Quercus sartorii y Q. xalapensis. Para ello, se revisó material de herbario y se recolectó material en 11 poblaciones distribuidas en los estados de Hidalgo, San Luis Potosí, Tamaulipas y Veracruz, en México, incluyendo 2 poblaciones simpátricas. Los resultados del análisis de componentes principales y discriminante mostraron que los caracteres que contribuyeron a agrupar los individuos en su respectiva especie son los relacionados con el tamaño del fruto, en particular el diámetro de la bellota, de la nuez y de la cúpula. La bellota de Q. sartorii es de menor tamaño que la de Q. xalapensis. La variación detectada no se atribuyó a la latitud o altitud. El fenograma mostró la separación de 2 grupos que corresponden a los individuos de las 2 especies estudiadas, si los caracteres del fruto son incluidos. Además, de los caracteres cuantitativos ya mencionados, 3 del patrón de venación y 2 anatómicos contribuyeron a reconocer los individuos de cada especie. Estas diferencias se mantuvieron en los individuos de las poblaciones simpátricas, por lo que los resultados apoyaron la distinción de Quercus sartorii y Q. xalapensis.A morphometric study was carried out in order to evaluate morphological variation of Quercus sartorii and Q. xalapensis and to contribute to their taxonomic delimitation. Herbarium specimens and material of 11 populations from Mexico in the states of Hidalgo, San Luis Potosí, Tamaulipas, and Veracruz, including 2 sympatric populations, were studied. Characters from foliar architecture, fruits and anatomical features of periderm and wood were analyzed through multivariate and phenetic methods. Principal component and discriminant analyses showed that fruit characters such as acorn, nut, and cupule diameters contributed to group individuals in their species, the acorn of Q. sartorii being smaller than that of Q

  20. Study of metastatic foci by CT in autopsied lung cancer

    International Nuclear Information System (INIS)

    Koga, Mitsuru; Nobe, Yoshifumi; Fujii, Kyoichi.

    1983-01-01

    The authors reexamined all of the image diagnoses made during whole hospitalization in 11 lung cancer cases with autopsy. Of 39 metastatic foci observed at autopsy in the liver, kidney, pancreas, adrenal and brain, 12 had been diagnosed on transverse CT images before death. Three foci were missed at initial readings. The period from CT to autopsy was less than 3 months for 9 of 12 correctly diagnosed foci. For 13 of 27 foci undetected by CT, CT was conducted more than 3 months before death. (Chiba, N)

  1. The anterior cruciate ligament: a study on its bony and soft tissue anatomy using novel 3D CT technology.

    Science.gov (United States)

    Tampere, Thomas; Van Hoof, Tom; Cromheecke, Michiel; Van der Bracht, Hans; Chahla, Jorge; Verdonk, Peter; Victor, Jan

    2017-01-01

    The purpose of this study is twofold: first, to visualize both the tibial and femoral bony insertion surfaces and second, to describe the anterior cruciate ligament (ACL) geometrically, using novel 3D CT imaging. In addition, new concepts of best-fit cylinder and central axis are introduced and evaluated. Eight unpaired knees of embalmed cadavers were used in this study. Following the dissection process, the ACL was injected with a contrast medium for CT imaging. The obtained CT images in extension, 45°, 90° and full flexion were segmented and rendered in 3D allowing morphological and morphometric analysis of the ACL. Anatomical footprint centres, femoral and tibial footprint surface area, best-fit ACL-cylinder intersection area, best-fit ACL-cylinder/footprint coverage ratio, best-fit ACL-cylinder central axis projections at the tibial and femoral footprint in the four positions were used to describe the anatomy of the ACL, based on the Bernard, Hertel and Amis grid. Based on these parameters, with the best-fit cylinder representing the bulk of the ACL, a changing fibre-recruitment pattern was seen with a moving position of the central axis from posterior to anterior on the femoral and tibial footprint, going from extension to flexion. Furthermore, the numerical data show an increase in tibial footprint coverage by the best-fit cylinder through the ACL when the knee is progressively flexed, whereas an inverse relationship was seen on the femoral side. This study is the first to describe the detailed anatomy of the human ACL with respect to its course and footprints using a 3D approach. It confirms the large difference and inter-patient variability between the tibial and femoral footprint area with the former being significantly smaller. The best-fit cylinder concept illustrates the recruitment pattern of the native ACL where in extension the postero-lateral fibres are recruited and in flexion rather the antero-medial bundle, which can be valuable information in

  2. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  3. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  4. Hepatic manifestations of tuberous sclerosis studied by US and CT

    International Nuclear Information System (INIS)

    Galant, J.; Marti-Bonmati, L.; Ripolles, T.; Martinez-Rodrigo, J.; Ferrer, M.D.

    1995-01-01

    Liver hamartomas in tuberous sclerosis (TS) have been uncommonly documented compared with hamartomatous lesions in other organs. We prospectively studied by US 21 patients that fulfilled the established criteria of TS, looking for hepatic and renal lesions. Nine patients (43%) showed multiple, rounded hyperechoic liver lesions. Of these patients, 8 were also studied with CT showing several round low-density fatty lesions. Multiple hyperechoic renal lesions similar to those described in the liver were present in 17 patients (81%). Fat-containing tumors in the liver in TS have been described as liver hamartomas. We believe, considering the high prevalence of liver hamartomas in patients with TS and the scarcity of fat-containing lesions in the general population, that their presence should be considered as a criterion of TS, even in the absence of histological confirmation. (orig.)

  5. Prevalence of incidental or unexpected findings on low-dose CT performed during routine SPECT/CT nuclear medicine studies

    International Nuclear Information System (INIS)

    Yap, Kelvin Kwok-Ho; Sutherland, Tom; Shafik-Eid, Raymond; Taubman, Kim; Schlicht, Stephen; Ramaseshan, Ganeshan

    2015-01-01

    In nuclear medicine, single-photon-emission computed tomography (SPECT) is often combined with ‘simultaneous’ low-dose CT (LDCT) to provide complementary anatomical and functional correlation. As a consequence, numerous incidental and unexpected findings may be detected on LDCT. Recognition of these findings and appropriate determination of their relevance can add to the utility of SPECT/CT. We aimed to evaluate the prevalence and categorise the relevance of incidental and unexpected findings on LDCT scans performed as part of routine SPECT/CT studies. All available LDCT scans performed as part of SPECT/CT studies at St. Vincent's Hospital Melbourne in the year 2013 were retrospectively reviewed. Two qualified radiologists independently reviewed the studies and any previous available imaging and categorised any detected incidental findings. A total of 2447 LDCT studies were reviewed. The relevance of the findings was classified according to a modified version of a scale used in the Colonography Reporting and Data System: E1 = normal or normal variant (28.0%); E2 = clinically unimportant (63.5%); E3 = likely unimportant or incompletely characterised (6.2%); E4 = potentially important (2.5%). Imaging specialists need to be cognisant of incidental and unexpected findings present on LDCT studies performed as part of SPECT/CT. Appropriate categorisation of findings and communication of potentially important findings to referring clinicians should form part of routine practice. The overall prevalence of potentially significant incidental and unexpected findings in our series was 8.7% (E3, 6.2%; E4, 2.5%) and was comparable to rates in other published imaging series.

  6. CT study of pancreatic diseases with modified dynamic scanning

    International Nuclear Information System (INIS)

    Qian Minghui; Zhu Guangying

    1990-01-01

    Experience of 20 cases modified dynamic CT scanning is presented. With a slight increased X-ray tube burden, it is possible to investigate tumor blood supply and find small pancreatic insulinoma with this method. The capsular sign typical for chronic traumatic pancreatic hematoma on CT is presented

  7. Evaluation of a PACS workstation for interpreting body CT studies

    International Nuclear Information System (INIS)

    Franken, E.A.; Berbaum, K.S.; Honda, H.; McGuire, C.; Weis, R.R.; Barloon, T.

    1989-01-01

    This paper reports conventional hard-copy images from 266 body CT studies compared with those provided by a picture archiving and communication system (PACS) workstation. PACS images were evaluated before and after use of various image processing features. Most cases were depicted equally well, but in about one-fourth of the cases, diagnostic features were shown more clearly on PACS images. When PACS images were viewed first, a change in diagnosis after subsequent hardcopy inspection was infrequent, but when hard-copy images were viewed first, the results were converse. The image processing features of PACS were critical for its superior performance. The ability of a PACS to provide both image display and manipulation results in the superiority of that system

  8. Nano-CT study on nanostructure of porous ceramics

    International Nuclear Information System (INIS)

    Wu Wenquan; Li Wenjie; Guan Yong; Yang Yunhao; Chen Jie; Zhou Jie; Yu Xiyue; Song Xiangxia; Tian Yangchao; Li Wei; Chen Chusheng

    2010-01-01

    The porous structure of ceramic materials has a great impact on their performance. However, the existing characterization techniques fail to give 3D structure of the ceramics. In this work, nano-CT imaging technique was used to study 3D structure of a ceramic fiber tube prepared by a phase inversion technology. The results showed the shape, direction, size distribution, and 3D map of the pores inside the ceramic wall. The pore size is 0.4-1.5 μm, with a porosity of 38.31%. The data can be used to improve their preparation processes and optimize the structure parameters, for applications in chemical, energy, environmental protection and other fields. (authors)

  9. Automated quantification of emphysema in CT studies of the lung

    International Nuclear Information System (INIS)

    Archer, D.C.; deKemp, R.A.; Coblentz, C.L.; Nahmias, C.

    1991-01-01

    Emphysema by definition is a pathologic diagnosis. Recently, in vivo quantification of emphysema from CT with point counting and with a GE 9800 CT scanner program called Density Mask has been described. These methods are laborious and time-consuming, making them unsuitable for screening. The propose of this paper is to create a screening test for emphysema. The authors developed a computer program that quantifies the amount of emphysema from standard CT-scans. The computer was programmed to recognize the lung edges on each section by identifying abrupt changes in CT numbers; grow regions within each lung to identify and separate the lungs from other structures; count regions of lung containing CT numbers measuring <-900 HU corresponding to areas of emphysema; and calculation the percentage of emphysema present from the volume of normal emphysematous lung. The programs were written in C and urn on a Sun 4/100 workstation

  10. Morphometric and landuse analysis: implications on flood hazards ...

    African Journals Online (AJOL)

    This study assessed the morphometric, landuse and lithological attributes of five basins (Iwaraja, Ilesa, Olupona, Osogbo I and Osogbo II) with particular reference to flood hazards in Ilesa and Osogbo metropolis, Osun State Nigeria. Ilesa town is situated within Iwaraja and Ilesa basins while Osogbo metropolis spread ...

  11. Discriminant analysis of morphometric differentiation in the West ...

    African Journals Online (AJOL)

    This study evaluated the usefulness of morphological characteristics to distinguish two important indigenous goat breeds in Nigeria. Fifteen morphometric traits were measured on West African Dwarf – WAD (n = 160) and Red Sokoto – RS (n = 142) goats that ranged in age of up to 19 months and were reared extensively in ...

  12. Study of CT and etiology In 11B cases of eoute headache without hemlplegla

    Institute of Scientific and Technical Information of China (English)

    Daoming Tong

    2000-01-01

    objectal To study the relation between CT and etiology of acute headache without hemiplegia. Methods 118 cases of acute headache without hemiplegia were studied with CT scan. The patients with normal CT were diagnosed with lumbar punc -tura or diagnostic standard for establishing disease. Results The first three etiologies were cerebrovescular disease (65 cases, 55%), migraine (25 cases, 21%), meningitis and encephalitis (19 cases, 155. 9%). 53% of patients with subarachnoid hemorrhage(SAH) was diagnosed in CT unnormal group, and 12.4% of patients with Sall was showed by lumbar puncture in CT normal group(P<0. 001). CT was normal in 18% of patients with a definite SAH(7/39). The positive rates of intracranial infection in CT normal group(by lumbar puncture) was reearkably higher than in CT unnormal group (18/58 versus 2/60, p<0.005), Conolusion CT is more sensitive to intracranial hemorrhage, tumor and infarction. SAH of a negative Ctscan is not rare. CT is far inferior to lumbar puncture in meningitis or encephalitis.

  13. Reducing dose in paediatric CT: a preliminary study of radiographers' knowledge

    International Nuclear Information System (INIS)

    Heagney, J.; Lewis, S.; Chaffey, C.; Howlett, G.; Moran, A.; McLean, D.

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs. Copyright (2003) Australian Institute of Radiography

  14. Reducing dose in paediatric CT: a preliminary study of radiographers' Knowledge

    International Nuclear Information System (INIS)

    Heagney, Jillian; Lewis, Sarah; Chaffey, Clare; Howlett, Genevieve; Moran, Alexander; McLean, Donald

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs Copyright (2003) Australian Institute of Radiography

  15. Dual resolution cone beam breast CT: A feasibility study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shen Youtao; Lai, Chao-Jen; Han Tao; Zhong Yuncheng; Ge Shuaiping; Liu Xinming; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.; Shaw, Chris C.

    2009-01-01

    Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 μm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

  16. Alveolar bone healing in rats: micro-CT, immunohistochemical and molecular analysis

    Directory of Open Access Journals (Sweden)

    Jaqueline Suemi HASSUMI

    2018-06-01

    Full Text Available Abstract Alveolar bone healing after upper incisor extraction in rats is a classical model of preclinical studies. The underlying morphometric, cellular and molecular mechanism, however, remains imprecise in a unique study. Objectives The aim of this study was therefore to characterize the alveolar bone healing after upper incisor extraction in rats by micro computed tomographic (Micro-CT, immunohistochemical and real-time polymerase chain reaction (RT-PCR analysis. Material and Methods Thirty animals (Rattus norvegicus, Albinus Wistar were divided into three groups after upper incisors extraction at 7, 14, and 28 days. Micro-CT was evaluated based on the morphometric parameters. Subsequently, the histological analyses and immunostaining of osteoprotegerin (OPG, receptor activator of nuclear kappa B ligand (RANKL and tartrate resistant acid phosphate (TRAP was performed. In addition, RT-PCR analyses of OPG, RANKL, the runt-related transcription factor 2 (RUNX2, osteocalcin (OC, osteopontin (OPN, osterix (OST and receptor activator of nuclear kappa B (RANK were performed to determine the expression of these proteins in the alveolar bone healing. Results Micro-CT: The morphometric parameters of bone volume and trabecular thickness progressively increased over time. Consequently, a gradual decrease in trabecular separation, trabecular space and total bone porosity was observed. Immunohistochemical: There were no differences statistically significant between the positive labeling for OPG, RANKL and TRAP in the different periods. RT-PCR: At 28 days, there was a significant increase in OPG expression, while RANKL expression and the RANKL/OPG ratio both decreased over time. Conclusion Micro-CT showed the newly formed bone had favorable morphometric characteristics of quality and quantity. Beyond the RUNX2, OC, OPN, OST, and RANK proteins expressed in the alveolar bone healing, OPG and RANKL activity showed to be essential for activation of basic

  17. A web-system of virtual morphometric globes

    Science.gov (United States)

    Florinsky, Igor; Garov, Andrei; Karachevtseva, Irina

    2017-04-01

    represents morphometric models with the resolution of 15'. In the final version of the system, we plan to implement a multiscale 3D visualization for models of 17 morphometric variables with the resolution from 15' to 30". The web-system of virtual morphometric globes is designed as a separate unit of a 3D web GIS for storage, processing, and access to planetary data [2], which is currently developed as an extension of an existing 2D web GIS (http://cartsrv.mexlab.ru/geoportal). Free, real-time web access to the system of virtual globes will be provided. The testing version of the system is available at: http://cartsrv.mexlab.ru/virtualglobe. The study is supported by the Russian Foundation for Basic Research, grant 15-07-02484. References 1. Florinsky, I.V., 2016. Digital Terrain Analysis in Soil Science and Geology. 2nd ed. Academic Press, Amsterdam, 486 p. 2. Garov, A.S., Karachevtseva, I.P., Matveev, E.V., Zubarev, A.E., and Florinsky, I.V., 2016. Development of a heterogenic distributed environment for spatial data processing using cloud technologies. International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 41(B4): 385-390.

  18. Correlation of F-18 FDG PET with morphometric tumor response after neoadjuvant chemoradiation in locally advanced (stage III) non-small cell lung cancer (NSCLC)

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Bonnet, R.; Presselt, N.; Przetak, C.; Junker, K.; Schneider, C.P.; Hoeffken, K.; Wendt, T.G.

    2002-01-01

    Aim: To determine the role of 2-[(18)F] fluoro-2- deoxy-D-glucose (FDG) positron emission tomography (PET) in morphometric tumor response after neoadjuvant chemoradiation, findings in 32 patients were analyzed prospectively in an ongoing multicenter trial (LUCAS-MD, Germany). Material and Methods: Inclusion criteria was histologically confirmed NSCLC stage IIIA/IIIB. For staging all patients received a PET scan in addition to a spiral CT and/or MRI before therapy. Neoadjuvant treatment consisted of 2-3 cycles of chemotherapy with paclitaxel (225 mg/m 2 ) and carboplatin (AUC 6), each d1 q22 and a block of chemoradiation (45Gy, 1.5Gy b.i.d., concomitant with paclitaxel (50 mg/m 2 ) and carboplatin (AUC = 2), each d1, d8, d15) followed by surgery. All patients received a second PET after completion of neoadjuvant therapy prior to surgery. Whole-body PET (ECAT Exact 47) studies (attenuation corrected, iteratively reconstructed) were obtained 60 min. after injection of 6 MBq/kg body weight F-18 FDG. For semi-quantitative analysis, the tumor standardized uptake values (SUV), the tumor to background SUV ratio (T/B ratio), the metabolic tumor diameter (MTD) and the metabolic tumor index (MTI = SUV x MTD) were assessed in all primary tumors and in metastatic lymph nodes. Additionally, image fusion of PET with CT data was applied (using a HERMES Computer, Nuclear Diagnostics, Sweden). Results: So far, all patients (7/32) with complete metabolic response in lymph node metastases detected by PET, had no vital tumor cells (morphometric regression grade III). In primary tumors showing complete metabolic response, the regression grade was IIB (less than 10% vital tumor cells) or III. Conclusion: Morphometric tumor response after neoadjuvant therapy correlates strongly with metabolic remission by FDG-PET. PET precedes the tumor response as measured by CT after neoadjuvant treatment and may predict the long term therapeutic outcome in stage III NSCLC

  19. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    Directory of Open Access Journals (Sweden)

    Moritz Kaup

    2016-12-01

    Full Text Available Background Computed tomography (CT low-dose (LD imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA. Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR and signal-to-noise ratios (SNR were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy. Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768. Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4. Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

  20. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  1. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  2. Morphometric Evaluation of Preeclamptic Placenta Using Light Microscopic Images

    Directory of Open Access Journals (Sweden)

    Rashmi Mukherjee

    2014-01-01

    Full Text Available Deficient trophoblast invasion and anomalies in placental development generally lead to preeclampsia (PE but the inter-relationship between placental function and morphology in PE still remains unknown. The aim of this study was to evaluate the morphometric features of placental villi and capillaries in preeclamptic and normal placentae. The study included light microscopic images of placental tissue sections of 40 preeclamptic and 35 normotensive pregnant women. Preprocessing and segmentation of these images were performed to characterize the villi and capillaries. Fisher’s linear discriminant analysis (FLDA, hierarchical cluster analysis (HCA, and principal component analysis (PCA were applied to identify the most significant placental (morphometric features from microscopic images. A total of 10 morphometric features were extracted, of which the villous parameters were significantly altered in PE. FLDA identified 5 highly significant morphometric features (>90% overall discrimination accuracy. Two large subclusters were clearly visible in HCA based dendrogram. PCA returned three most significant principal components cumulatively explaining 98.4% of the total variance based on these 5 significant features. Hence, quantitative microscopic evaluation revealed that placental morphometry plays an important role in characterizing PE, where the villous is the major component that is affected.

  3. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  4. The posterior communicating artery: morphometric study in 3D angio-computed tomography reconstruction. The proof of the mathematical definition of the hypoplasia.

    Science.gov (United States)

    Dzierżanowski, J; Szarmach, A; Słoniewski, P; Czapiewski, P; Piskunowicz, M; Bandurski, T; Szmuda, T

    2014-08-01

    The aim of this study was to investigate the morphometry of the posterior communicating artery (PCoA), on the basis of angio-computed tomography (CT), and to give proof of the mathematical definition of the term "hypopal sia of the PCoA". One hundred 3-dimensional (3D) angio-CT images, performed in adult patients with bilateral reconstruction of the PCoA (200 results) were used tocalculate the morphometry of the vessel. The average length of the vessel on the right side was 14.48 ± 3.47 mm, andon the left side 14.98 ± 4.77 mm (in women 14.75 mm, in men 14.70 mm). The mean of the diameter at the "proximal" point (the junction with P1) on the right side was 1.49 ± 0.51 mm, and on the left 1.46 ± 0.47 mm (in women 1.44 mm and in men 1.51 mm). The mean of the diameter in the "distal" part (the connection with ICA) on the right side was 1.4 ± 0.49 mm, and on the left 1.37 ± 0.41 mm (in women 1.38 mm, and in men 1.39 mm). No statistical correlation between the length and the diameter of the PCoA in relation to the sex and side was shown. On the basis of our measurements, we defined the hypoplasia of the artery as the estimated value less than the average diameter minus the standard deviation. The percentage distribution was as follows: the left artery 15.5%, the right artery 24%, women 11.5%, and the men 9%. Similarly to the above parameters, we have not found any statistical differences. The presence of the foetal origin was noted in 25% of the radiological examinations. The infundibular widening was visualised in 11.5% of cases of 3D reconstructions. The agenesis of PCoA was found in 9% (never bilaterally), and in 1 case the unilateral duplication of the artery was observed. No statistical differences between those parameters in relation to sex and the examined side were revealed. Morphological calculation of the PCoA on the basis of angio-CT from adult patients did not show any statistical differences depending on sex or the investigated side. The presented

  5. Fatty liver: prospective comparative study with sonography and CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kim, Y. M.; Kim, W. S.; Choi, B. I.; Lee, J. S.; Han, C. K.; Kim, C. W.

    1990-01-01

    To identify the reasonable criteria in detection of the degree of Fatty liver, we prospectively evaluated sonograms and CT scans in 33 Patients With bright liver on sonography. On sonograms, we analyzed the echogenicity of the liver, acoustic attenuation, and visualization of the portal vein and the diaphragm, Each criterion was scored from 0 to 2. CT criterion for fatty liver was assessed by the attenuation difference between the liver and the spleen on nonocontrast CT scans, The average sonographic grade for CT Grade I was 1.3, Grade II was 2.1,and Grade III was 2.8. The accurate detection rate of each sonographic grade was as follows, Grade

  6. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  7. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    Science.gov (United States)

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  8. Feasibility study of CT perfusion imaging for prostate carcinoma

    International Nuclear Information System (INIS)

    Cullu, Nesat; Kantarci, Mecit; Ogul, Hayri; Pirimoglu, Berhan; Karaca, Leyla; Kizrak, Yesim; Adanur, Senol; Koc, Erdem; Polat, Ozkan; Okur, Aylin

    2014-01-01

    The aim of this feasibility study was to obtain initial data with which to assess the efficiency of perfusion CT imaging (CTpI) and to compare this with magnetic resonance imaging (MRI) in the diagnosis of prostate carcinoma. This prospective study involved 25 patients with prostate carcinoma undergoing MRI and CTpI. All analyses were performed on T2-weighted images (T2WI), apparent diffusion coefficient (ADC) maps, diffusion-weighted images (DWI) and CTp images. We compared the performance of T2WI combined with DWI and CTp alone. The study was approved by the local ethics committee, and written informed consent was obtained from all patients. Tumours were present in 87 areas according to the histopathological results. The diagnostic performance of the T2WI+DWI+CTpI combination was significantly better than that of T2WI alone for prostate carcinoma (P < 0.001). The diagnostic value of CTpI was similar to that of T2WI+DWI in combination. There were statistically significant differences in the blood flow and permeability surface values between prostate carcinoma and background prostate on CTp images. CTp may be a valuable tool for detecting prostate carcinoma and may be preferred in cases where MRI is contraindicated. If this technique is combined with T2WI and DWI, its diagnostic value is enhanced. (orig.)

  9. Morphological study of maxillary canine region based on CT

    International Nuclear Information System (INIS)

    Yamada, Maiko; Takamori, Hitoshi; Ide, Yoshiaki; Yosue, Takashi

    2010-01-01

    The maxilla is generally known as a site where anatomical limitations make it difficult to obtain sufficient bone volume. A large amount of bone exists in the canine region between the anterior margin of the maxillary sinus and the piriform aperture margin. Although this region is crucial for implant treatments, there have not been any reports on morphological studies of the region. In this study, we investigated the morphology of the canine region based on CT, and also the morphology and position of the maxillary sinus located posterior to the canine region. The results were as follows: In the area above the anterior nasal spine, the higher the level, the smaller the mesio-distal length and the bucco-lingual width tended to become. In the area above the anterior nasal spine, the mesio-distal length and the bucco-lingual width tended to be smaller in female patients than in male patients. In the area above the anterior nasal spine, no significant differences in mesio-distal length and bucco-lingual width were observed between dentulous and edentulous jaws. The morphology of the maxillary sinus was mainly of an inverse-trapezoidal, circular, or triangular form. The position of the anterior wall of the maxillary sinus was most frequently found at the site corresponding to the second premolar. Through this study, we have reconfirmed that the canine region is vital for implant treatments in the maxilla. (author)

  10. PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan

    Energy Technology Data Exchange (ETDEWEB)

    Wong, K.; Rahill, J.; Cleary, K. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Petrillo, S.; Earl-Graef, D. [Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Banovac, F.; Levy, E. [Computer Aided Interventions and Medical Robotics (CAIMR), Imaging Science and Information Systems (ISIS) Center, Georgetown Univ. Medical Center, Washington, DC (United States); Dept. of Radiology, Georgetown Univ. Hospital, MedStar Health, Washington, DC (United States); Shekhar, R. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    2007-06-15

    Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

  11. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  12. Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography.

    Science.gov (United States)

    Song, Jin Wook; Cha, Jung Yul; Bechtold, Till Edward; Park, Young Chel

    2013-01-01

    To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro-computed tomography (micro-CT) for bone morphometric analysis. A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. BIC values from micro-CT analysis decreased when the PSD increased (P micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P micro-CT, at least 5 PSD from the metal implant surface is needed.

  13. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  14. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  15. A CT study of the prevalence of carotid artery calcification in dental patients

    International Nuclear Information System (INIS)

    Yoon, Suk Ja; Lee, Jae Seo; Yoon, Woong

    2006-01-01

    Stroke is one of the leading causes of death in Korea. Atherosclerotic disease in the carotid artery bifurcation is the most common cause of stroke. The carotid artery calcification is easily appreciated by CT(Computed tomography). CT is often taken in a dental hospital for the diagnosis of inflammation. injury, cyst or tumor on maxillofacial region. However, there was no report of carotid artery calcification on CT in dental patients. The presence of carotid artery calcification was evaluated by an experienced radiologist on CT scans of 287 patients (166 males, 121 females, average age 42, range 6 to 86 years) and the medical history of the patient and the interpretation of CT were reviewed. Carotid artery calcification was detected on CT scans of 57 patients (19.8%; 35 males, 22 females). All the male patients with carotid artery calcification were older than 50, and all the female patients with carotid artery calcification were older than 60. Among the 57 patients, 10 had Diabetes mellitus, 20 had cardiovascular disease, 3 had history of stroke and 3 underwent radiation therapy for head and neck cancer. Carotid artery calcification was not included in the interpretation of CT of dental patients except one patient. The prevalence of carotid artery calcification on CT of dental patients was about 20% in this study. Carotid artery calcification should be included in the interpretation of CT of dental patients

  16. Construction of Individual Morphological Brain Networks with Multiple Morphometric Features

    Directory of Open Access Journals (Sweden)

    Chunlan Yang

    2017-04-01

    Full Text Available In recent years, researchers have increased attentions to the morphological brain network, which is generally constructed by measuring the mathematical correlation across regions using a certain morphometric feature, such as regional cortical thickness and voxel intensity. However, cerebral structure can be characterized by various factors, such as regional volume, surface area, and curvature. Moreover, most of the morphological brain networks are population-based, which has limitations in the investigations of individual difference and clinical applications. Hence, we have extended previous studies by proposing a novel method for realizing the construction of an individual-based morphological brain network through a combination of multiple morphometric features. In particular, interregional connections are estimated using our newly introduced feature vectors, namely, the Pearson correlation coefficient of the concatenation of seven morphometric features. Experiments were performed on a healthy cohort of 55 subjects (24 males aged from 20 to 29 and 31 females aged from 20 to 28 each scanned twice, and reproducibility was evaluated through test–retest reliability. The robustness of morphometric features was measured firstly to select the more reproducible features to form the connectomes. Then the topological properties were analyzed and compared with previous reports of different modalities. Small-worldness was observed in all the subjects at the range of the entire network sparsity (20–40%, and configurations were comparable with previous findings at the sparsity of 23%. The spatial distributions of the hub were found to be significantly influenced by the individual variances, and the hubs obtained by averaging across subjects and sparsities showed correspondence with previous reports. The intraclass coefficient of graphic properties (clustering coefficient = 0.83, characteristic path length = 0.81, betweenness centrality = 0.78 indicates

  17. Stroke Pattern in Enugu. A Study of CT images in South East Nigeria ...

    African Journals Online (AJOL)

    Non-contrast cranial computed tomography (CT) scan reliably distinguishes between ischemic stroke (IS) and hemorrhagic strokes (HS) and will provide a reliable characterization of stroke types in the developing countries. Aims: To examine stroke types based on CT Imaging studies and the differences in stroke types ...

  18. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  19. Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

    DEFF Research Database (Denmark)

    Zheng, Yi; Yang, Yan; Rogowska, M.

    2017-01-01

    to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection....... The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales...... of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk....

  20. Cystic degeneration of liver malignancies. Study by US and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Takashi; Nakano, Satoshi; Kitamura, Kimio; Watahiki, Hajime; Takeda, Isao

    1983-03-01

    CT and US were carried out on 81 patients with hepatocellular carcinoma, 20 patients with cholangiocellular carcinoma and 94 patients with metastatic liver cancer. 1) Cystic degeneration was observed in one with hepatocellular carcinoma (1.2%), one with cholangiocellular carcinoma (5.0%) and 12 with metastatic liver cancer (12.8%) by US, but this change was observed in only 5 by CT (1,0,4, respectively). Metastatic liver cancer showed the highest incidence among these tumors. 2) The characteristics of cystic degeneration of the liver tumors were thickened wall and irregularity of the inner surface of the wall. 3) Judging from macroscopic and histopathological findings, liquefactive necrosis in the tumors was shown as ''echoluent'' area. We concluded that cystic degeneration was one of the important findings in metastatic liver cancer and that careful observation by US and CT avoided the confusion with other hepatic cystic diseases.

  1. Multi-institutional collaborating study on CT scan of schizophrenia

    International Nuclear Information System (INIS)

    Takahashi, Ryo; Sato, Tokijiro; Okuma, Teruo

    1984-01-01

    More abnormal CT findings were observed in nuclear schizophrenic patients (55%) than in the matchable controls with a statistically significant difference. According to the site of the brain, these were marked in the whole ventricle (especially the third ventricle) and in the cortex including the longitudinal fissure, frontal lobe, temporal lobe, and sylvian fissure (especially of the left hemisphere). There was no correlation between the cerebral ventricular enlargement and the patient's age, the duration of illness or drug dosage, suggesting that the enlargement may exist from the onset of the disease. Aging or taking drug(s) were also not responsible for the cortical atrophy. CT findings were associated mainly with negative symptoms. In particular, the association between abnormalities of the left hemisphere and psychiatric symptoms was marked. Direct measurements of CT images revealed significantly higher incidences only in the third ventricular enlargement in schizophrenic patients. These results suggest the possibility that subtypes of schizophrenia can be classified. (Namekawa, K.)

  2. Identification of the species of the Cheilosia variabilis group (Diptera, Syrphidae) from the Balkan Peninsula using wing geometric morphometrics, with the revision of status of C. melanopa redi Vujic, 1996

    NARCIS (Netherlands)

    Francuski, Lj.; Vujic, A.; Kovacevic, A.; Ludoski, J.; Milankov, V.

    2009-01-01

    The present study investigates phenotypic differentiation patterns among four species of the Cheilosia variabilis group (Diptera, Syrphidae) using a landmark-based geometric morphometric approach. Herein, wing geometric morphometrics established species boundaries that confirm C. melanopa and C.

  3. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    Science.gov (United States)

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  4. CT quantitative diagnosis in fatty liver. An experimental study

    International Nuclear Information System (INIS)

    Zhao Hong; Li Binxiang; Zhang Lizhong; Liang Jianfang

    1997-01-01

    Purpose: To evaluate the relation between liver fat content and CT value in animal experiment for the diagnosis and treatment of fatty liver in clinical practice. Materials and methods: Fatty liver model was established in 30 Wistar rats (experimental group), 5 rats was used as the control group. The 5 rats of the control group and 5 rats randomly chosen from experimental group at the first, second, third, and the fourth weekends, were measured for the CT number of total liver. Three pieces of liver specimen from each rats were removed from left, central and right lobes for histologic examination. The ratio of liver fat content to liver volume (Vv value) was measured by microscopic image pattern analyzer. Results: Significant linear negative correlation (r = -0.950, t = 12.90, P<0.001) was found between CT and Vv values. Conclusion: Using CT monitoring, the degree and amount of liver fat could be assessed and liver biopsy obviated in the diagnosis and follow up during treatment of fatty liver

  5. Geoinformatics for assessing the morphometric control on ...

    Indian Academy of Sciences (India)

    natural disasters are one of the serious geo-hazards, ... Natural features such as land use and land cover, soil and .... steps followed for the generation of morphometric ... language. Infiltration number. Area, perimeter, basin length, min & max.

  6. Reducing dose in head CT: A phantom study

    International Nuclear Information System (INIS)

    Perez Diaz, M.; Carvalho, A. E.; Andrade, M. E.; Khoury, H. J.

    2013-01-01

    Thirty two head CT scans were acquired employing an anthropomorphic phantom which contains small lesions in posterior fosse, using 2 scanners, one with 64 slices 'Siemens Sensation' and other with 6 slices P hilip Brilliance . Parameters as Tube current (I [mA]), Collimation (C [mm]), spectrum energy (kVp) and dynamic range were changed during studies, looking for the optimal acquisition/processing conditions which permit both, good lesion detectability and the lowest dose. Air kerma (mGy) was measured with a ionization chamber and the air kerma index (Ca,100 [mGy]) was calculated as dose index. Image quality was analyzed by 5 expert criteria using a 5 points-scale (1=poor, 2=fair, 3=good, 4=very good, 5=excellent) and also using 5 Figure of merit in the spatial and frequency domains: Contrast C(%), Contrast to Noise Ratio CNR, Signal to Noise Ratio SNR, Normalized Mean Square Error (NMSE) and the Spectral Distance (SD). Objective and subjective results were correlated. We observed that doses can be diminished until a 25% respect to the usual practice with both technologies, diminishing mainly the mAs, without affecting lesion detection. As a result, we propose an optimized protocol for each scanner as follow: The use of 250 mAs, 120 kVp and the collimation of 6 slices x 1.50 mm per rotation to detect the lesions in posterior fosse with good image quality for the Philips Brilliance 6 tested, while 150 mAs, 100 kVp and slice thickness of 3 mm were needed with the Siemens Sensation 64. (Author)

  7. Chest CT study of patients with asbestos exposure, 1

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki

    1988-01-01

    Thin-slice high-resolution computed tomographic (CT) findings of 36 patients (34 men, 2 women) with histories of long-term (11 to 43 years) occupational asbestos exposure (AS) were analyzed for pulmonary abnormalities, which were classified by the subpleural curvilinear shadow (SCLS) and/or the extent of honeycomb shadow (HS) into five types (O to IV). SCLS was detected in 22 patients (62 %), and HS in 14 patients (39 %). SCLS was distributed mainly in the lower lobe in patients with mild pulmonary fibrosis (Types I and II) and in segments where fibrosis was mild in patients with HS (Types III and IV). This may reflect the initiation of pulmonary fibrosis leading to the formation of a HS. Most (63.7 %) SCLS measured > 5 cm but < 10 cm in length and occurred < 1 cm from the inner chest wall in all cases. Radiologic-pathologic correlation of SCLS and HS in CT imagings, achieved in two post mortem specimens, seemed to indicate that SCLS was associated with the initial change of fibrosing bronchiolo-alveolitis, which is characteristic of pulmonary asbestosis. Thin-slice high-resolution CT findings of 36 patients with AS and 33 patients with idiopathic interstitial pneumonia (IIP) were compared. Though the incidence of SCLS was low (21 %) in this series of IIP, its presence suggests that SCLS is not specific to pulmonary asbestosis but occurs also in chronic interstitial pneumonia. In order to explore the mechanism of the appearance of SCLS, further analysis of CT and histopathologic findings not only of pulmonary asbestosis and IIP but also of many other pulmonary interstitial diseases is necessary. It could be considered that thin-slice high-resolution CT which first detected SCLS is very useful in the visualization of fine structures of the lungs. (author)

  8. A study of long boone measurement by CT scanogram - Comparison with spot scanogram -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Kang, Heung Sik; Jung, Jin Wook; Yeon, Kyung Mo

    1987-01-01

    CT scanogram is a new technique for measuring leg length discrepancy and has many advantage as compared with conventional spot scanogram. 30 dried bones were measured by direct measurement, spot scanogram and CT scanogram. Accuracy of CT scanogram was compared with spot scanogram. For evaluation of systemic error of CT, steel rulers and dried bones were measured at two different window settings. Decentering error in spot scanogram was measured by using dried bones, and 180 spots of 30 clinical cases of Beli-thompson studies were reviewed for evaluation of incidence and degree of decentering. The results of measurements of CT and spot scanogram in ideal position and technique were equivalent to those of direct measurements. But in spot scanogram, significant errors were noted in flexion status and decentered film. 54 spot (42.9%) of 30 clinical cases were decentered more than 1 cm. In CT scanogram, decentering error was completely excluded and shortening due to flexion deformity was overcomed by lateral scanogram. CT scanogram is a simple and accurate method for leg length measurement. Thus we recommend CT scanogram as a routine use for evaluation of leg length discrepancy.

  9. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  10. A clinical study of mucin producing tumor of pancreas with US and CT

    International Nuclear Information System (INIS)

    Suzuki, Tadashi; Imaizumi, Toshihide; Nakasako, Toshiaki; Hatori, Takashi; Takasaki, Ken

    1999-01-01

    We conclude that multilocular cysts are 3 cm and over, or elevated types as in mucin producing pancreatic tumors must be neoplasm in the pathological study. But, we question whether or not we can diagnose the elevated type before the operation. So, for the purpose of making a clear guideline of diagnosis for elevated types, we examined 46 operating cases of mucin producing tumors (Kuroda type I) documented from 1985 to 1994. We examined existence, height and properties of elevated lesions, 25 cases of elevated type and 21 cases of flat type. There is a significant difference of height with US and CT, and existence of enhancement with CT. As a result, we have obtained the following guidelines. The height of an elevated lesion with US is 4 mm and over, and the height of that with CT is 3 mm and over. It is enhanced with CT. Therefore, we find it possible to diagnose elevated types with US and CT. (author)

  11. 2D/3D Quantification of bone morphometric parameter changes using X-ray microtomograpphy with different pixel sizes

    International Nuclear Information System (INIS)

    Vidal, F.; Assis, J.T. de; Lopes, R.T.; Lima, I.

    2014-01-01

    In recent years, bone quantification led to a deeper knowledge of the 3D microarchitecture. In this study the bone architecture of rats was investigated based on 2D/3D morphometric analysis using microcomputed tomography, aiming at determining the effect of the image acquisition pixel on the quality of some 2D/3D morphometric parameters, such as porosity and trabecular density. Six pairs of bone samples were used and the scans were carried out using high microcomputed tomography system, operating at three different pixel sizes of 33.3 μm, 15.0 μm and 9.5 μm. The results showed 2D parameters values lower than those obtained in the 3D analysis, mainly for trabecular density, separation and thickness. - Highlights: ► Bone quantification led to a deeper knowledge of the 3D microarchitecture. ► μCT was used in order to investigate condyles bone in 03 different pixel sizes. ► The results showed 2D parameters values lower than those obtained in the 3D analysis. ► The parameters trabecular density, separation and thickness were the most affected

  12. Clinical utility of FDG PET/CT in acute complicated pyelonephritis - results from an observational study

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Chih-Hsing [Mackay Memorial Hospital at Taipei, Department of Nuclear Medicine, Taipei (China); Tseng, Jing-Ren; Yen, Tzu-Chen [Chang Gung Memorial Hospital at Linkou, Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Science, College of Medicine, Taoyuan (China); Lee, Ming-Hsun [Chang Gung Memorial Hospital at Linkou, Division of Infectious Diseases, Department of Internal Medicine, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou, Biostatistics Unit, Clinical Trial Center, Taoyuan (China)

    2018-03-15

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of {sup 18}F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course. (orig.)

  13. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    International Nuclear Information System (INIS)

    Kamijo, Keiichi

    1994-01-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122±18 H.U.(±SD) and did not change significatly with advancing age. The mean thyroid CT number (±SD) of 85±22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116±22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T 3 were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65±11 H.U. and increased significantly to 76±14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102±11 H.U. and fell significantly to 84±16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57±7 H.U. in 6 patients with silent thyroiditis and of 61±5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author)

  14. Clinical studies on thyroid CT number in Graves' disease and destructive thyrotoxicosis

    Energy Technology Data Exchange (ETDEWEB)

    Kamijo, Keiichi (Kamijo Thyroid and Pituitary Clinic, Sapporo (Japan))

    1994-02-01

    The purpose of the present study was to investigate CT Hounsfield unit (H.U.) of the thyroid in hyperthyroid and euthyroid Graves' disease and destructive thyrotoxicosis. The mean thyroid CT number in 95 controls was 122[+-]18 H.U.([+-]SD) and did not change significatly with advancing age. The mean thyroid CT number ([+-]SD) of 85[+-]22 H.U. in 60 patients with hyperthyroid Graves' disease was significantly lower than either in normal controls or 116[+-]22 H.U. in 11 patients with euthyroid Graves' disease. Comparison of thyroid hormones and TSH receptor Ab values of untreated patients with a normal and an abnormally low thyroid CT number showed that serum total and free T[sub 3] were significantly higher in the latter group than the former group. With respect to the effect of methimazol (MMI) on the thyroid CT number, in the untreated 10 patients with a low thyroid CT number, the initial mean CT number was 65[+-]11 H.U. and increased significantly to 76[+-]14 H.U. after treatment with MMI. In contrast, in 6 patients with a normal thyroid CT number prior to therapy, the initial mean thyroid CT number was 102[+-]11 H.U. and fell significantly to 84[+-]16 H.U. after treatment with MMI. The thyroid CT number in destructive thyrotoxicosis is markedly decreased to less than 70 H.U. and the mean values of 57[+-]7 H.U. in 6 patients with silent thyroiditis and of 61[+-]5 H.U. in 7 with subacute thyroiditis differ significantly from Graves' disease. In conclusion, the thyroid CT number is significantly reduced in hyperthyroid Graves' disease, normal in euthyroid Graves' disease and markedly decreased in destructive thyrotoxicosis. The high T-3 value seemed to play an important role in the pathogenesis of a decline in the thyroid CT number in Graves' disease. An antithyroid drug therapy caused two different changes in the thyroid CT number, depending on whether the thyroid CT number prior to therapy was normal or low. (author).

  15. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    Science.gov (United States)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  16. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    International Nuclear Information System (INIS)

    Osman, N D; Shamsuri, S B M; Razali, M A S M; Isa, S M; Tan, Y W

    2017-01-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDI vol and CTDI w ) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDI w ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients. (paper)

  17. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Maria; Honey, Ian [Trust, Medical Physics Department, Guy' s and St. Thomas' NHS Foundation, London (United Kingdom); Goh, Vicky [King' s College London, St Thomas' Hospital, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Beggs, Shaun [Bradford Teaching Hospitals NHS Foundation Trust, Radiation Physics Services, Bradford (United Kingdom); Bridges, Andrew; Wayte, Sarah [Radiology Physics University Hospitals Coventry and Warwickshire NHS Trust, Coventry (United Kingdom); Clewer, Philip [Medical Physics Department, University Hospital Southampton NHS Foundation Trust, Southampton (United Kingdom); Davis, Anne [Portsmouth Hospitals NHS Trust, Medical Physics Department, Portsmouth (United Kingdom); Foy, Trevelyan [Royal Cornwall Hospital NHS Trust, Medical Physics Department, Truro (United Kingdom); Fuller, Karen [Sheffield Teaching Hospitals NHS Foundation Trust, Medical Physics Department, Sheffield (United Kingdom); George, Jennifer [University Hospital of North Staffordshire NHS Trust, Medical Physics Department, Stoke-on-Trent (United Kingdom); Higginson, Antony [Portsmouth Hospitals NHS Trust, Department of Radiology, Portsmouth (United Kingdom); Iball, Gareth [Leeds Teaching Hospitals NHS Trust, Department of Medical Physics and Engineering, Leeds (United Kingdom); Mutch, Steve [Oxford University Hospitals NHS Trust, Radiation Physics and Protection Department, Oxford (United Kingdom); Neil, Shellagh; Sutton, David [NHS Tayside, Medical Physics Department, Dundee, Scotland (United Kingdom); Rivett, Cat [Plymouth Hospitals NHS Trust, Clinical and Radiation Physics, Plymouth (United Kingdom); Slater, Andrew [Oxford University Hospitals NHS Trust, Department of Radiology, Oxford (United Kingdom); Weir, Nick [Queen' s Medical Research Institute, Clinical Research Imaging Centre, Edinburgh, Scotland (United Kingdom); Collaboration: on behalf of the PROSPeCT Investigators

    2014-09-15

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI{sub vol}, DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml{sup -1} and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  18. Quality control within the multicentre perfusion CT study of primary colorectal cancer (PROSPeCT): results of an iodine density phantom study

    International Nuclear Information System (INIS)

    Lewis, Maria; Honey, Ian; Goh, Vicky; Beggs, Shaun; Bridges, Andrew; Wayte, Sarah; Clewer, Philip; Davis, Anne; Foy, Trevelyan; Fuller, Karen; George, Jennifer; Higginson, Antony; Iball, Gareth; Mutch, Steve; Neil, Shellagh; Sutton, David; Rivett, Cat; Slater, Andrew; Weir, Nick

    2014-01-01

    To assess the cross-centre consistency of iodine enhancement, contrast-to-noise ratio and radiation dose in a multicentre perfusion CT trial of colorectal cancer. A cylindrical water phantom containing different iodine inserts was examined on seven CT models in 13 hospitals. The relationship between CT number (Hounsfield units, HU) and iodine concentration (milligrams per millilitre) was established and contrast-to-noise ratios (CNRs) calculated. Radiation doses (CTDI vol , DLP) were compared across all sites. There was a linear relationship between CT number and iodine density. Iodine enhancement varied by a factor of at most 1.10, and image noise by at most 1.5 across the study sites. At an iodine concentration of 1 mg ml -1 and 100 kV, CNRs ranged from 3.6 to 4.8 in the 220-mm phantom and from 1.4 to 1.9 in the 300-mm phantom. Doses varied by a factor of at most 2.4, but remained within study dose constraints. Iterative reconstruction algorithms did not alter iodine enhancement but resulted in reduced image noise by a factor of at most 2.2, allowing a potential dose decrease of at most 80 % compared to filtered back projection (FBP). Quality control of CT performance across centres indicates that CNR values remain relatively consistent across all sites, giving acceptable image quality within the agreed dose constraints. (orig.)

  19. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  20. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  1. Comparative study on developmental stages of the clavicle by postmortem MRI and CT imaging

    DEFF Research Database (Denmark)

    Larsen, Sara Tangmose; Lynnerup, Niels; Jensen, K.E.

    2013-01-01

    Objectives: The developmental stages of the clavicles are important for forensic age estimation purposes in adolescents. This study compares the 4-stage system to evaluate the ossification of the medial end of the clavicle as visualized by magnetic resonance imaging (MRI) and computed tomography...... (CT). As several forensic institutes routinely perform CT scans, the large amount of available data may serve as reference sample for MRI in specific cases. Material and methods: This prospective study included an MRI and CT scan of 47 autopsy cases performed prior to medico-legal autopsy (age range...

  2. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  3. Clinical study on primary epilepsy by computerized analysis of CT

    International Nuclear Information System (INIS)

    Tominaga, Hidefumi; Ueyama, Kenichi; Mizutani, Hiroshi; Imamura, Keisuke; Yoshidome, Kazushi; Matsumoto, Kei

    1985-01-01

    CT scans were examined by conventional linear measurement method and computerized analysis in 17 patients with primary epilepsy (Group A). Results were compared with those in healthy volunteers (Group B). Relationship between CT and EEG findings was also examined. The maximum width of the third cerebral ventricle (TCV) was narrowed in Group A than in Group B, with statistically significant difference. Low density rates (LDR) in Group A tended to be lower than those in Group B. There was significant difference in narrowed maximum width of TCV between Group A presenting with sudden dysrhythmia and Group B. For this type of Group A, LDR was significantly lower than that for Group B. These results suggest some changes in the brain in young epilepsy patients, especially those presenting with sudden dysrhythemia. (Namekawa, K.)

  4. Brain atrophy in Huntington's disease: A CT-scan study

    International Nuclear Information System (INIS)

    Starkstein, S.E.; Folstein, S.E.; Brandt, J.; McDonnell, A.; Folstein, M.

    1989-01-01

    CT-scan measurements of cortical and subcortical atrophy were carried out in 34 patients with Huntington's disease (HD). While a significant correlation was observed between parameters of subcortical atrophy (bicaudate ratio, bifrontal ratio and third ventricular ratio) and duration of the disease, there was no significant correlation between these parameters and age. On the other hand, measurements of cortical atrophy (frontal fissure ratio and cortical sulci ratio) correlated significantly with age but not with duration of the disease. When a group of 24 HD patients were compared on CT-scan measurements with a group of 24 age-matched normal controls, significant differences were obtained for all the variables examined, but the bicaudate ratio showed the highest sensitivity and specificity. Even mildly affected patients, with duration of motor symptoms less than 3 years had higher bicaudate ratios than age-matched controls. (orig.)

  5. Study of three-dimensional image display by systemic CT

    International Nuclear Information System (INIS)

    Fujioka, Tadao; Ebihara, Yoshiyuki; Unei, Hiroshi; Hayashi, Masao; Shinohe, Tooru; Wada, Yuji; Sakai, Takatsugu; Kashima, Kenji; Fujita, Yoshihiro

    1989-01-01

    A head phantom for CT was scanned at 2 mm intervals from the cervix to the vertex in an attempt to obtain a three-dimensional image display of bones and facial epidermis from an ordinary axial image. Clinically, three-dimensional images were formed at eye sockets and hip joints. With the three-dimensional image using the head phantom, the entire head could be displayed at any angle. Clinically, images were obtained that could not be attained by ordinary CT scanning, such as broken bones in eye sockets and stereoscopic structure at the bottom of a cranium. The three-dimensional image display is considered to be useful in clinical diagnosis. (author)

  6. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    International Nuclear Information System (INIS)

    Poortman, Pieter; Lohle, Paul N.M.; Schoemaker, Cees M.; Cuesta, Miguel A.; Oostvogel, Henk J.M.; Lange-de Klerk, Elly S.M. de; Hamming, Jaap F.

    2010-01-01

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  7. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  8. Study on the development of frontal sinuses by morphometric analysis of the skull - doi: 10.4025/actascibiolsci.v35i2.13334

    Directory of Open Access Journals (Sweden)

    Carolina Peixoto Magalhães

    2013-05-01

    Full Text Available The frontal sinuses are cranial areas of clinical, forensic and pathology importance whose development mechanisms are still poorly defined. Nasal airflow and brain development are two of the main theories. Current analysis debates whether they are the real determinants of frontal sinuses growth, which may be proved by the skull’s morphometric analysis. Four groups of measures related to the external cranial architecture, the pyriform aperture, orbital cavities and frontal sinuses were defined. Thirty-three skulls of individuals, mean age 68 years, from the Laboratory of Anatomy of the Academic Centre of Victoria – UFPE – Brazil, were used. Statistical analysis showed total agenesis of the frontal sinus in 18.2% of the skulls. There was significant correlation between the development of the right frontal sinus and the pyriform aperture, and between the left frontal sinus and two cranial measurements (p ≤ 0.05. Significant differences between mean of pyriform aperture areas of the skulls with or without sinuses were also reported (p ≤ 0.01. Results supported the fact that there was a modulation activity by nasal aeration and brain formation in the development of frontal sinuses.

  9. Application of geometric morphometrics to the study of postnatal size and shape changes in the skull of Calomys expulsus

    Directory of Open Access Journals (Sweden)

    Erika Hingst-Zaher

    2000-06-01

    Full Text Available Abstract We analyzed ontogenetic patterns of landmarks for 169 laboratory-raised specimens of Calomys expulsus, at 0, 5, 10, 20, 30, 50, 100, 200, and 300 days of age, using two-dimensional geometric morphometrics. There is sexual dimorphism in size, with males smaller than females at earlier ages, but larger after 50 days. Differences in shape between sexes are strong only until 10 days of age, suggesting that shape is more constrained than size. Combining sexes, there is strong variation in size with age, reduced after 200 days, while most of the variation in shape occurs before 20 days. This dissociation is common for sigmodontine rodents, and might be the basis of heterochronic processes responsible for the morphological variation of this South American group. Centroid size does not show any reduction in the coefficient of variation over ages, while Procrustes distances within sucessive ages are reduced after 20 days. Uniform component and the more global partial warps explain most of the shape changes with age. Cranial and Facial parts of the skull increase in size at different rates with a relative lengthening of the snout and decrease in height of the braincase. We were unable to detect a clear pattern of integration for the rostrum and braincase, besides that shown by landmark displacements.

  10. Pathophysiological study of experimental hydrocephalus with computed tomography (CT) scan

    International Nuclear Information System (INIS)

    Murata, Takaho

    1980-01-01

    In order to investigate the pathophysiological changes during a development of hydrocephalus, the observations employing computed tomography (CT) scans and monitorings of intracranial epidural pressure (EDP) were performed in a series of kaolin-induced canine hydrocephalus. According to ''volume index'' of ventricles which was calculated from printed-out CT numbers, great individual variations were recognized in the degree of a ventricular enlargement as well as the rate of EDP. They are thought to be due to the difference in types of hydrocephalus, which have been induced by a discrepancy in the site and degree of an obstruction caused by kaolin. Periventricular lucency (PVL) of various degrees were also detected on CT scans of experimental hydrocephalus. It was always marked in the superolateral angle of frontal horn of the lateral ventricles, and differed in degree from severe to mild. PVLs were distinct in the acute stage with high EDP, and gradually became indistinct and had a tendency to disappear thereafter along with decreased EDP. They immediately disappeared after shunting operation. The pathogenesis of PVL was investigated with histological examinations, as well as by using contrast enhancement, Metrizamide ventriculography, the analysis of linear density profiles, and the measurement of regional cerebral blood flow (rCBF). Consequently, PVLs in hydrocephalus are considered to represent an acute edema or a chronic CSF retention in the periventricular white matter caused by increase of water content. In other words, they are regarded as a sign of present or preceding intraventricular hypertension on CT scan, and may become a clinical indication for shunting operation. (author)

  11. Postnatal development of the atlas and axis: CT study

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Hyung Jin; Lim, Myung Kwan; Kim, Won Hong; Jeon, Yong Sun; Kim, Jeong Ho; Kim, Sung Tae

    2003-01-01

    To evaluate normal postnatal development of the atlas and axis by means of CT scanning. We prospectively analyzed CT scans of the developing atlas and axis of 200 normal children aged less than 14, investigating the CT appearance of these regions with particular attenuation to two synchondroses related to the atlas and four synchondroses and one ossification center related to the axis. Fusion varying was categorized as either low (grade1-5) or high (grade4-5), according to the varying degrees of fusion at each synchondrosis of ossification center. Neurocentral synchondrosis of the atlas was low grade in all children less than five, and high grade in all aged nine or more, while posterior synchondrosis of the atlas was low grade in 97% of children less than three and high grade in 99% aged three or more. As for the axis, neurocentral synchondrosis was low grade in all children less than three, and high grade in 97% of children aged five or more. PS of the axis was low grade in both children less than 6 months, and high grade in all aged two years or more. Dentocentral synchondrosis of the axis was low grade in 93% of children less than three and high grade in 96% of those aged at least five. Intradental axial synchondrosis was high grade in all children. Fusion of the terminal ossicle with the remainder of the dens was low in all children less than five and high in 97% of those aged nine of more. CT can help determine the parameters of normal postnatal development of the atlas and axis. A knowledge of normal ossification patterns of these regions may help provide an understanding of developmental anomalies and also help prevent confusion with fractures

  12. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  13. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  14. Intracranial ring enhancing lesions in dogs: a correlative CT scanning and neuropathologic study

    International Nuclear Information System (INIS)

    Wolf, Michael; Pedroia, Vince; Higgins, Robert J.; Koblik, Philip D.; Turrel, Jane M.; Owens, Jerry M.

    1995-01-01

    This retrospective analysis of 15 dogs with postcontrast ring enhancing brain lesions, each detected by a single Computed Tomography (CT) examination, searched for any association between their CT appearance and the pathologic diagnosis. In a subgroup of these dogs (n = 71) necropsied within 2 days of the last CT scan, we evaluated whether there was any anatomic correlation between the ring zone and the histopathologic features of the lesions. Our study consisted of eight dogs with primary brain tumors (3 meningiomas, 3 astrocytomas, 1 mixed glioma, 1 oligodendroglioma), 4 with metastatic brain tumors (2 fibrosarcomas, 1 mammary carcinoma, 1 melanoma) and 3 with non-neoplastic brain lesions (2 intraparenchymal hemorrhages, 1 pyogranulomatous meningoencephalitis). The overall size and shape of the contrast enhancing CT lesions, as well as the thickness, surface texture and degree of enhancement of the ring were subjectively evaluated. No association was found between the CT lesion characteristics and the pathologic diagnosis. In the sub-group of dogs euthanatized within 2 days of the CT examination, distinct histologic features which anatomically correlated with the zone of ring enhancement were found in 3 of 7 lesions. The findings of this study are consistent with those of ring-enhancing lesions in people, and indicates that CT ring enhancement is a nonspecific phenomenon which can occur in a variety of neoplastic and non-neoplastic lesions in the dog

  15. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  16. A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry.

    Science.gov (United States)

    Damstra, Janalt; Fourie, Zacharias; De Wit, Marnix; Ren, Yijin

    2012-02-01

    Morphometric methods are used in biology to study object symmetry in living organisms and to determine the true plane of symmetry. The aim of this study was to determine if there are clinical differences between three-dimensional (3D) cephalometric midsagittal planes used to describe craniofacial asymmetry and a true symmetry plane derived from a morphometric method based on visible facial features. The sample consisted of 14 dry skulls (9 symmetric and 5 asymmetric) with metallic markers which were imaged with cone-beam computed tomography. An error study and statistical analysis were performed to validate the morphometric method. The morphometric and conventional cephalometric planes were constructed and compared. The 3D cephalometric planes constructed as perpendiculars to the Frankfort horizontal plane resembled the morphometric plane the most in both the symmetric and asymmetric groups with mean differences of less than 1.00 mm for most variables. However, the standard deviations were often large and clinically significant for these variables. There were clinically relevant differences (>1.00 mm) between the different 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features. The difference between 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features were clinically relevant. Care has to be taken using cephalometric midsagittal planes for diagnosis and treatment planning of craniofacial asymmetry as they might differ from the true plane of symmetry as determined by morphometrics.

  17. Accurate localization of intracavitary brachytherapy applicators from 3D CT imaging studies

    International Nuclear Information System (INIS)

    Lerma, F.A.; Williamson, J.F.

    2002-01-01

    Purpose: To present an accurate method to identify the positions and orientations of intracavitary (ICT) brachytherapy applicators imaged in 3D CT scans, in support of Monte Carlo photon-transport simulations, enabling accurate dose modeling in the presence of applicator shielding and interapplicator attenuation. Materials and methods: The method consists of finding the transformation that maximizes the coincidence between the known 3D shapes of each applicator component (colpostats and tandem) with the volume defined by contours of the corresponding surface on each CT slice. We use this technique to localize Fletcher-Suit CT-compatible applicators for three cervix cancer patients using post-implant CT examinations (3 mm slice thickness and separation). Dose distributions in 1-to-1 registration with the underlying CT anatomy are derived from 3D Monte Carlo photon-transport simulations incorporating each applicator's internal geometry (source encapsulation, high-density shields, and applicator body) oriented in relation to the dose matrix according to the measured localization transformations. The precision and accuracy of our localization method are assessed using CT scans, in which the positions and orientations of dense rods and spheres (in a precision-machined phantom) were measured at various orientations relative to the gantry. Results: Using this method, we register 3D Monte Carlo dose calculations directly onto post insertion patient CT studies. Using CT studies of a precisely machined phantom, the absolute accuracy of the method was found to be ±0.2 mm in plane, and ±0.3 mm in the axial direction while its precision was ±0.2 mm in plane, and ±0.2 mm axially. Conclusion: We have developed a novel, and accurate technique to localize intracavitary brachytherapy applicators in 3D CT imaging studies, which supports 3D dose planning involving detailed 3D Monte Carlo dose calculations, modeling source positions, shielding and interapplicator shielding

  18. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  19. Comparison of cerebrospinal fluid dynamics studied by computed tomography (CT) and radioisotope (RI) cisternography

    International Nuclear Information System (INIS)

    Tamaki, N.; Kanazawa, Y.; Asada, M.; Kusunoki, T.; Matsumoto, S.

    1978-01-01

    CT and RI cisternography were done on 55 cases with normal and abnormal CSF circulation. Of 19 cases in which both studies were done, 14 cases disclosed a good correspondence. The remaining five cases showed no correspondence because of technical failure. Analyzing the results, CT cisternography demonstrates pathology of the CSF dynamics in a more precise and quantitative manner than RI cisternography does. Metrizamide CT cisternography will soon be the most reliable method of investigation for the evaluation of the CSF kinetics. (orig.) [de

  20. SPECT/CT co-registration of nuclear medicine studies and technologists: challenges and victories

    International Nuclear Information System (INIS)

    Cameron, P.J.

    2002-01-01

    Full text: A dual modality SPECT/CT gamma camera was installed in the Department of Nuclear Medicine at Fremantle Hospital, WA in 2000. The challenges were satisfying the requirements of the Radiological Advisory Council of WA with respect to room modifications and presence of a radiographer during CT acquisitions and once installation was complete, learning to operate the camera in dual modality mode. The victories are making CT/SPECT acquisitions a simple and routine procedure and the impact of the co-registered studies in both diagnostic and therapeutic applications in our practice. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. A study on CT-guided stereotactic technique for functional neurosurgery

    International Nuclear Information System (INIS)

    Uetsuhara, Koichi; Asakura, Tetsuhiko; Hirahara, Kazuho; Gondo, Masazumi; Oda, Hiroshige

    1987-01-01

    Recently, CT-guided stereotactic surgery has become of major interest, and some authors have discussed its potential in functional neurosurgery. The following is a comparative study of the CT-guided stereotactic technique and the conventional roentogenographic stereotactic technique. The Brown-Roberts-Wells apparatus was used for both types of procedures. 37 stereotactic procedures were performed on 35 patients under local anesthesia; 16 for stereotactic biopsy and 21 for stereotactic functional neurosurgery. Target points for stereotactic biopsy were determined by the CT-guided technique and target points for functional neurosurgery were determined by the conventional roentogenographic technique. The correlation with the position of target point determined by both techniques was investigated in the 21 functional neurosurgical procedures. On these occasions the authors used the reformatted horizontal and sagittal CT through the anterior and posterior commissure to determine the position of target point by the CT-guided technique. Results: It was found that the AC-PC line crossed with Reid's base line at angle of 11 ± 1 deg, and therefore it is important to obtain a CT images including AC-PC line at this angle. When applying the CT guided stereotactic procedure for functional surgery, it should be known that there could be a discrepancy within 2 mm from the conventional target determination. (author)

  2. Application of artificial neural networks in the CT study of solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Wang Xiaohua; Ma Daqing; Chen Hui; Gao Peiyi; Zhou Xinhua

    2006-01-01

    Objective: To establish a new-type discriminative method in differentiating benign from malignant solitary pulmonary nodule (SPN) on high-resolution CT/thin-section CT by using artificial neural networks theory in the CT diagnostic study of SPN. Methods: Two hundred SPNs pathologically proved by operation or biopsy (primary pulmonary carcinoma 135 eases, benign nodules 65 cases) were collected, 3 clinical characteristics (age, sex, with or without bloody sputum) and 9 high-resolution CT/thin-section CT characteristics (location, long and short diameter, contour, spiculation, halo sign, air-space, relation with the adjacent blood vessels and pleura) were analyzed. 140 cases were randomly selected to form the training samples, on which artificial neural networks model (BP networks) was built and compared with Logistic model from Statistical Package for the Social Science (SPSS) software. Results: The total consistent rate of BP neural networks (98.0%, 196/200) was higher than that of Logistic model (86.0%, 172/200) (P<0.001). Areas under ROC curve were 0.996±0.004 and 0.936±0.017, respectively, and the difference between the two was significant (P<0.001). Conclusion: Using high-resolution CT and thin-section CT in combination with artificial neural networks theory is feasible, and it is expected to become a useful and reliable clinical tool in differentiating benign from malignant SPN. (authors)

  3. Feasibility of perfusion CT technique integrated into conventional {sup 18}FDG/PET-CT studies in lung cancer patients: clinical staging and functional information in a single study

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide; Capraro, Cristina; Sironi, Sandro [University of Milano-Bicocca, School of Medicine, Milan (Italy); University of Milano-Bicocca, Department of Diagnostic Radiology, H.S. Gerardo Monza, Via Pergolesi 11, Monza, Milan (Italy); Guerra, Luca [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); De Ponti, Elena [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Medical Physics, Monza (Italy); Messa, Cristina [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); Tecnomed Foundation, University of Milano-Bicocca, Institute for Bioimaging and Molecular Physiology, National Research Council, Milan (Italy)

    2013-02-15

    To assess the additional functional vascular information and the relationship between perfusion measurements and glucose metabolism (SUVmax) obtained by including a perfusion CT study in a whole-body contrast-enhanced PET/CT protocol in primary lung cancer lesions. Enrolled in this prospective study were 34 consecutive patients with a biopsy-proven diagnosis of lung cancer who were referred for contrast-enhanced PET/CT staging. This prospective study was approved by our institutional review board, and informed consent was obtained from all patients. Perfusion CT was performed with the following parameters: 80 kV, 200 mAs, 30 scans during intravenous injection of 50 ml contrast agent, flow rate 5 ml/s. Another bolus of contrast medium (3.5 ml/s, 80 ml, 60-s delay) was administered to ensure a full diagnostic contrast-enhanced CT scan for clinical staging. The perfusion CT data were used to calculate a range of tumour vascularity parameters (blood flow, blood volume and mean transit time), and tumour FDG uptake (SUVmax) was used as a metabolic indicator. Quantitative and functional parameters were compared and in relation to location, histology and tumour size. The nonparametric Kruskal-Wallis rank sum test was used for statistical analysis. A cut-off value of 3 cm was used according to the TNM classification to discriminate between T1 and T2 tumours (i.e. T1b vs. T2a). There were significant perfusion differences (lower blood volumes and higher mean transit time) between tumours with diameter >30 mm and tumours with diameter <30 mm (p < 0.05; blood volume 5.6 vs. 7.1 ml/100 g, mean transit time 8.6 vs. 3.9 s, respectively). Also there was a trend for blood flow to be lower in larger lesions (p < 0.053; blood flow 153.1 vs. 98.3 ml/100 g tissue/min). Significant inverse correlations (linear regression) were found between blood volume and SUVmax in tumours with diameter >30 mm in diameter. Perfusion CT combined with PET/CT is feasible technique that may provide

  4. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  5. Vitamin B12 deficiency: Characterization of psychometrics and MRI morphometrics.

    Science.gov (United States)

    Hsu, Yen-Hsuan; Huang, Ching-Feng; Lo, Chung-Ping; Wang, Tzu-Lan; Tu, Min-Chien

    2016-01-01

    Vitamin B12 is essential for the integrity of the central nervous system. However, performances in different cognitive domains relevant to vitamin B12 deficiency remain to be detailed. To date, there have been limited studies that examined the relationships between cognitions and structural neuroimaging in a single cohort of low-vitamin B12 status. The present study aimed to depict psychometrics and magnetic resonance imaging (MRI) morphometrics among patients with vitamin B12 deficiency, and to examine their inter-relations. We compared 34 consecutive patients with vitamin B12 deficiency (serum level ≤ 250 pg/ml) to 34 demographically matched controls by their cognitive performances and morphometric indices of brain MRI. The correlations between psychometrics and morphometrics were analyzed. The vitamin B12 deficiency group had lower scores than the controls on total scores of Mini-Mental Status Examination (MMSE) and Cognitive Abilities Screening Instrument (CASI) (both P psychometric and morphometric indices, pronounced correlations between bicaudate ratio and long-term memory, mental manipulation, orientation, language, and verbal fluency were noted (all P < 0.01). Vitamin B12 deficiency is associated with a global cognition decline with language, orientation, and mental manipulation selectively impaired. Preferential atrophy in frontal regions is the main neuroimaging feature. Although the frontal ratio highlights the relevant atrophy among patients, the bicaudate ratio might be the best index on the basis of its strong association with global cognition and related cognitive domains, implying dysfunction of fronto-subcortical circuits as the fundamental pathogenesis related to vitamin B12 deficiency.

  6. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    International Nuclear Information System (INIS)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung

    1994-01-01

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings

  7. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of)

    1994-11-15

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings.

  8. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality : a digital phantom study

    NARCIS (Netherlands)

    Bernatowicz, K; Keall, P; Mishra, P; Knopf, A; Lomax, A; Kipritidis, J

    PURPOSE: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on

  9. Morphometric Identification of Queens, Workers and Intermediates in In Vitro Reared Honey Bees (Apis mellifera).

    Science.gov (United States)

    De Souza, Daiana A; Wang, Ying; Kaftanoglu, Osman; De Jong, David; Amdam, Gro V; Gonçalves, Lionel S; Francoy, Tiago M

    2015-01-01

    In vitro rearing is an important and useful tool for honey bee (Apis mellifera L.) studies. However, it often results in intercastes between queens and workers, which are normally are not seen in hive-reared bees, except when larvae older than three days are grafted for queen rearing. Morphological classification (queen versus worker or intercastes) of bees produced by this method can be subjective and generally depends on size differences. Here, we propose an alternative method for caste classification of female honey bees reared in vitro, based on weight at emergence, ovariole number, spermatheca size and size and shape, and features of the head, mandible and basitarsus. Morphological measurements were made with both traditional morphometric and geometric morphometrics techniques. The classifications were performed by principal component analysis, using naturally developed queens and workers as controls. First, the analysis included all the characters. Subsequently, a new analysis was made without the information about ovariole number and spermatheca size. Geometric morphometrics was less dependent on ovariole number and spermatheca information for caste and intercaste identification. This is useful, since acquiring information concerning these reproductive structures requires time-consuming dissection and they are not accessible when abdomens have been removed for molecular assays or in dried specimens. Additionally, geometric morphometrics divided intercastes into more discrete phenotype subsets. We conclude that morphometric geometrics are superior to traditional morphometrics techniques for identification and classification of honey bee castes and intermediates.

  10. Comparison of Ct and MRI in the study of the pituitary gland

    International Nuclear Information System (INIS)

    Juliani, G.; Avataneo, T.; Potenzoni, F.; Sorrentino, T

    1989-01-01

    Normal CT and MR anatomy was studied in two series (53 and 25 cases respectively) of young volunteers of both sexes, asymptomatic and certainly without lesions of the pituitary gland. 115 other pathological cases (73 hyperprolactinemias, 8 acromegalies, 15 Cushing syndromes, 2 hyperthyroidisms, 17 non-secreting adenomas) were examined using both CT and MRI. Both an accurate review of the relative literature and the results of our own series prove that MR is superior to CT in diagnosing pituitary microadenomas (3.2% not diagnosed with MRI and 25.8% not diagnosed with CT), in the follow-up of prolactinomas subjected to medical therapy and in the study of extrasellar involvement of pituitery adenomas, particularly with regard to the demonstration of compression of the optic chiasma

  11. Pulmonary actinomycosis: CT studies of diagnostic and post-treatment findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Jung; Song, Sun Wha; Bo, Seal Hwang; Park, Hyun Jin; Kim, Hyeon Sook; Kim, Ki Jun; Kim, Horrim; Park, Seog Hee [College of Medicine, the Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2008-05-15

    To investigate the value of the computed tomography (CT) in the study of diagnostic and post-treatment findings of pulmonary actinomycosis. Clinical data and CT findings were retrospectively analyzed in 10 patients with histopathologically confirmed pulmonary actinomycosis. We analyzed the initial CT findings in search of patterns and distributions which suggest possible lung abnormalities and found the pleura, chest wall, and lymphadenopathy to be involved as part of the indicators of lung abnormalities. We analyzed follow-up CT findings for changes in the lungs after antibiotic therapy and recurrence after surgery. Of the 10 patients analyzed by CT for lung lesions, seven had been diagnosed with alcoholism and nine were male. The initial CTs (n = 10) indicated that all the pulmonary lesions were solitary without chest wall involvement. However, a transfissural extension was observed in 20% of the study population (n = 2). Furthermore, peripheral lung distribution and adjacent pleural thickening was observed in 70% of the study population (n = 7). Within the consolidation (n = 6) or mass (n = 4), a central low density with peripheral enhancement was seen in 70% of the study population (n = 7). A follow-up CT of the seven cases following antiobiotic therapy revealed that four cases showed minimal improvement or aggravation of their lung lesions, whereas three cases showed resolution or improvement. The improvement of the central low density was related to the improvement of consolidation or mass. Furthermore the presence of fibrosis was observed after the resolution of pulmonary lesions (n = 2). No relationship was found between the duration and response of antibiotic therapy. A follow-up CT (n = 4) subsequent to a lung resection revealed the onset of chest wall actinomycosis and a thickened pleura in one case. The results of this study highlight the value of the CT in pulmonary actinomycosis in order to diagnose and evaluate antibiotic responses, complications, or

  12. Physical and morphometric characterization of indigenous cattle of Assam

    Directory of Open Access Journals (Sweden)

    A. Haque

    2011-01-01

    Full Text Available The present investigation was undertaken to study the physical and morphometric characteristics in indigenous cattle of Assam. The data pertain to 339 indigenous cattle of different categories. The physical characteristics included colour pattern of body coat, muzzle, tail switch, hoof and horn. Body length, height at wither, heart girth, pouch girth, length of tail, switch, neck, ear and head were taken up for morphometric characterization. The main body coat colour of indigenous cattle was brown (31.18% followed by white (28.53%, fawn (15.29%, grey (13.53%, black (4.41% and mixed (7.06%. The prominent colour of tail switch was black (74.53%. Most of animals had black muzzle (86.47%, black hooves (84.71% and black horn (100%. Morphometric characteristics data obtained were classified according to location, age group and sex of the animal. The means for body length, height at wither, heart girth, pouch girth, length of tail, switch, neck, ear and head were 83.668±0.590, 91.942±0.55, 113.146±0.738, 121.181±0.761, 54.196±0.527, 26.098±0.186, 32.705±0.166, 18.131±0.111 and 35.035±0.195 cm respectively. Age and sex had significant effect on all the morphometric characters however, location effect was non significant. The indigenous cattle of Assam are comparatively smaller in size than most of the recognized breeds of cattle however coat colour showed sizeable variation. The data generated for indigenous cattle of Assam would be useful to characterize them.

  13. CT study of infantile cerebral vitamin B1 deficiency (analysis of 22 cases)

    International Nuclear Information System (INIS)

    Liu Bin; Xi Meifang; Wang Mengding; Wang Chaoxiu

    1998-01-01

    Purpose: To study the CT features of infantile cerebral vitamin B 1 deficiency. Methods: The authors retrospectively reviewed the clinical manifestations and CT findings of 22 cases of infantile vitamin B 1 deficiency. Results: The main clinical signs were seizure malaise dullness and vomiting. CT scans showed bilateral symmetrical hypodense foci in lenticular nucleus (20/22), head of caudate nucleus (15/22), thalamus (3/22), anterior limb of internal capsule (4/22), external capsule (1/22) and para-ventricle white matter (2/22), and in many cases, signs of cerebral atrophy. 22 cases received thiamine treatment and were fully recovered. Conclusion: The authors concluded that bilateral symmetric hypodense foci in lenticular nucleus thalamus, head of caudate nucleus, anterior limb of internal capsule, external capsule and para-ventricle white matter were important CT signs suggestive of infantile cerebral vitamin B 1 deficiency

  14. Lesion concordance, image quality and artefacts in PET/CT. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Krause, B.J.; Eschmann, S.M.; Juergens, K.U.; Kuehl, H.; Pfannenberg, A.C.; Stollfuss, J.; Weckesser, M.

    2010-01-01

    This study had three major objectives: (1.) to record the number of concordant (both in PET and CT) pathological lesions in different body regions/organs, (2.) to evaluate the image quality and (3.) to determine both, the quantity and the quality of artefacts in whole body FDG PET/CT scans. Routine whole body scans of 353 patients referred to FDG-PET/CT exams at 4 university hospitals were employed. All potentially malignant lesions in 13 different body regions/organs were classified as either concordant or suspicious in FDG-PET or CT only. In the latter case the diagnostic relevance of this disparity was judged. The image quality in PET and CT was rated as a whole and separately in 5 different body regions. Furthermore we investigated the frequency and site of artefacts caused by metal implants and oral or intravenous contrast media as well as the subjective co-registration quality (in 4 body regions) and the diagnostic impact of such artefacts or misalignment. In addition, the readers rated the diagnostic gain of adding the information from the other tomographic method. In total 1941 lesions (5.5 per patient) were identified, 1094 (56%) out of which were concordant. 602 (71%) out of the 847 remaining lesions were detected only with CT, 245 (29%) were only PET-positive. As expected, CT particularly depicted the majority of lesions in the lungs and abdominal organs. However, the diagnostic relevance was greater with PET-only positive lesions. Most of the PET/CT scans were performed with full diagnostic CT including administration of oral and intravenous contast media (> 80%). The image quality in PET and CT was rated excellent. Artefacts occurred in more than 60% of the scans and were mainly due to (dental) metal implants and contrast agent. Nevertheless there was almost no impact on diagnostic confidence if reading of the non attenuation corrected PET was included. The co-registration quality in general was also rated as excellent. Misalignment mostly occurred due

  15. Exploring Eucladoceros ecomorphology using geometric morphometrics.

    Science.gov (United States)

    Curran, Sabrina C

    2015-01-01

    An increasingly common method for reconstructing paleoenvironmental parameters of hominin sites is ecological functional morphology (ecomorphology). This study provides a geometric morphometric study of cervid rearlimb morphology as it relates to phylogeny, size, and ecomorphology. These methods are then applied to an extinct Pleistocene cervid, Eucladoceros, which is found in some of the earliest hominin-occupied sites in Eurasia. Variation in cervid postcranial functional morphology associated with different habitats can be summarized as trade-offs between joint stability versus mobility and rapid movement versus power-generation. Cervids in open habitats emphasize limb stability to avoid joint dislocation during rapid flight from predators. Closed-adapted cervids require more joint mobility to rapidly switch directions in complex habitats. Two skeletal features (of the tibia and calcaneus) have significant phylogenetic signals, while two (the femur and third phalanx) do not. Additionally, morphology of two of these features (tibia and third phalanx) were correlated with body size. For the tibial analysis (but not the third phalanx) this correlation was ameliorated when phylogeny was taken into account. Eucladoceros specimens from France and Romania fall on the more open side of the habitat continuum, a result that is at odds with reconstructions of their diet as browsers, suggesting that they may have had a behavioral regime unlike any extant cervid. © 2014 Wiley Periodicals, Inc.

  16. A study comparing the use of dynamic CT and Xe-CT CBF for ischemic cerebro-vascular disease

    International Nuclear Information System (INIS)

    Terada, Tomoaki; Kikuchi, Haruhiko; Kuriyama, Yoshihiro; Nagata, Izumi; Yamagata, Sen; Naruo, Yoshito; Minamikawa, Jun; Kaneko, Takaji; Sakashita, Yoshiharu

    1987-01-01

    The simultaneous measurement of dynamic computerized tomography scanning (DCT) with an iodine-contrast enhancement material bolus injection and a simultaneous xenon CT-CBF-study was done on 15 patients (8 cases of unilateral internal carotid occlusion; 3, of unilateral middle cerebral arterial occlusion, and 4, without any major cerebral arterial occlusion or significant arterial stenosis) with ischemic cerebro-vascular diseases at the subacute and/or chronic stage. The value of the width and corrected first moment (cMT1) as well as their functional images, as acquired from DCT data, were compared to the 1-CBF value and the 1-CBF map of the xenon CT-CBF-study. A comparison of the functional images of DCT and 1-CBF showed that there was a good correlation between them in the cases without leptomeningeal anastomosis as a collateral circulation. However, a poor correlation between them was found in the cases with leptomeningeal anastomosis as a collateral circulation. The correlation of 1-CBF and 1/width with 1/cMT1 was significant (r = 0.78, p < 0.01) in the former cases, but it was not significant in the latter cases. The results of our data were thought to be due to the difference in the tracer inflow pattern between the cases without leptomeningeal anastomosis and those with it as a collateral circulation. The factor of cerebral blood volume should be considered in a more detailed study, although our cases did not include any patients with acute cerebral infarction or recanalized cases, which are thought to show various changes in the cerebral blood volume. The 1/width and 1/cMT1 values acquired from DCT well reflected the CBF in the cases without leptomeningeal anastomosis as a collateral circulation. (author)

  17. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  18. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  19. An experimental study for qualitatively diagnosing stapes lesions by helical 3-dimensional CT

    International Nuclear Information System (INIS)

    Kawaue, Akifumi; Kuki, Kiyonori; Yamanaka, Noboru; Nishimura, Michihiko

    2001-01-01

    To evaluate qualitative diagnosis of stapes lesions by 3-dimensional computed tomography (3D-CT) combined with superselective image processing (3D-SS) of stapes, we studied helical 3D-CT on a phantom model of the temporal bone. Two stapes models were used-1 made from the bone filler, Celatite, consistent in bone density but changing in cross sectional area, and the other made from an apacerum rod used in quantitative computed tomography (QCT), consistent in cross sectional area but changing in bone density. These stapes models were put into a skull phantom and analyzed by helical 3D-CT. The influence of the tympanic cavity conditions on CT images of stapes was evaluated by filling the phantom model with Vaseline following 3D selective reconstruction. In all stapes models, lowering the lower CT window width threshold resulted in an enlarged cross-sectional area of the model. The higher the bone density, the lower the increase in cross-sectional area in the image. The stapes model with lower density had greater influence on the imaging by tympanic cavity conditions and was likely to be misdiagnosed as showing higher bone density. Based on the experimental study, 3D-SS by helical 3D-CT appears to be a useful measure for qualitatively diagnosing stapes lesions. (author)

  20. A roentgenographical study of the morphology of ventricles of the brain using computed tomography (CT)

    International Nuclear Information System (INIS)

    Inugami, Atsushi

    1981-01-01

    A basic experiment using an experimental model for the ventricles of the brain was made of the reproductivity of CT images using a whole body CT scanner, and the dimensions of the ventricles of 450 children on CT images were measured, to study changes in dimensions of the ventricles with the method for providing the sectional planes, or with the type of the CT scanner used, and the children with ventricular abnormalities were further studied. The sectional plane at OM-0 0 clinically gave a better reproductivity of the ventricles than at OM-15 0 . The measurements of the ventricles proved to vary with the mean value and also with the window width. In measuring the dimensions of the ventricles on the CT image, the ratio of widths of the anterior horn, third ventricle, corpus and posterior horn to that of the cerebral parenchyma was found to be correlated to the dimensions of the ventricles. No particular changes with the age structure of each cerebroventricular index (CVI) were noted. Apparent differences in the measurement were noted between each CVI of the abnormal group and the normal. CT scanning is a safe, easy non-invasive method for screening and observing the couse of ventricular diseases, accompanied by less risk. (author)

  1. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  2. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Honda, Eiichi; Tetsumura, Akemi; Kurabayashi, Tohru

    2011-01-01

    Purpose: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases. Materials and methods: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom. Results: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64x) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64. Conclusions: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases.

  3. Morphometric evaluation of Arbor Acre parent stock broilers reared ...

    African Journals Online (AJOL)

    Morphometric evaluation of Arbor Acre parent stock broilers reared in ... Economic importance of morphometric parameters such as live weight and body ... (R2) value of 60.30 included forecast indices such as BL, WS, WL, TL, BG and SL.

  4. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the

  5. Three dimensional CT imaging of ossicular chain: a preliminary study

    International Nuclear Information System (INIS)

    Hu Chunhong; Zhong Shenbin; Fu Yindi; Zhu Wei; Wang Xueyuan; Chen Jianhua; Ding Yi

    2001-01-01

    Objective: To analysis the features of normal and abnormal ossicular chain in three dimensional images and asses the best parameters and its usefulness in diagnosis and treatment of chronic otitis media (COM). Methods: All patients, including 43 patients with normal ears and 24 ears with COM, were examined using spiral CT with inner ear software, 1-mm slice width and 1 pitch. SSD method was used in three dimensional reconstruction and the threshold was 100-300 Hu. Results: In normal cases, Malleus, incus, stapes crura, incudomalleal joints and incudostapedial joints were displayed well, but stapes footplate unsatisfactorily. The disruption of the ossicular chain showed in three-dimensional images in cases of chronic otitis media was in accord with that seen in the operation. Conclusion: It is very important for imaging with high quality through selecting proper parameters, and three-dimensional image can provide valuable information for surgery

  6. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  7. Comparative Study of the CT Findings and Clinical Features in Pediatric and Adult Sialadenitis

    International Nuclear Information System (INIS)

    Han, Jong Kyu; Jo, Seong Shik; Kim, Sang Won; Kim, Young Tong; Shin, Hyeong Cheol; Kim, Il Young; Lee, Yong Man

    2010-01-01

    We wanted to compare the CT findings and clinical features of parotitis and submandibular sialadenitis in children and adults and to evaluate the statistical significance of these in different age groups and the usefulness of a CT scan. Ninety-seven adults and 36 pediatric patients with sialadenitis were included in this retrospective study. Regardless of the site of involvement, we evaluated the CT findings and clinical manifestations between the pediatric and adult groups, and between the pediatric and adult parotitis and submandibular sialadenitis groups. At last, all the patients were classified into seven age groups. Abscess formations were more prominent in the parotitis groups, and sialiths were more common in the submandibular sialadenitis group with the lowest incidence in the young children group (≤ 10 years). Cellulitis seen on a CT scan showed a higher incidence in the adult parotitis group, and this finding was closely connected with pain. A number of patients showed cervical lymphadenitis on a CT scan and this coincided with lymph node palpation. Tonsillitis associated sialadenitis was common in the pediatric group. The therapeutic durations were longer in the pediatric parotitis patient group and the adult submandibular sialadenitis group. CT scans were very helpful to evaluate for abscess, stone, lymphadenitis and estimating the associated clinical manifestations such as swelling, palpable lymph nodes, pain with operation and the therapeutic plan

  8. The comparative study of CT and MRI on femoral head necrosis

    International Nuclear Information System (INIS)

    Lin Yunliang; Liu Xianghua; Wu Shiqiang; Zeng Kangnian

    2008-01-01

    Objective: To compare the imaging features of CT and MRI in the femoral head necrosis as well as their pathological basis. Methods: 18 cases (30 hips) with femoral head necrosis proved by follow-up studies or pathology were analyzed, including 3 cases of pathological data. Results: The blurred high-density sclerotic line on CT in 28 hips were corresponded to 'line-like signs' on MRI, whereas, the other two hips without blurred high-density sclerosis line appeared 'line-like signs' on MRI. The normal area surrounded by the high-density line on CT in 26 hips were corresponded to fat-like signal area in 12 hips and mixed signal area in 14 hips on MRI. The other 4 hips with blurred bony trabeculum surrounded by the high-density line on CT showed mixed signal intensity on MRI. Conclusion: The high-density sclerotic line on CT corresponds to 'line-like sign' on MRI, which was considered as reactive interface between necrotic and viable region, was a specific signs to diagnose FHN. Compared with CT, MRI can accurately reflect pathological process during different repaired stages. (authors)

  9. A primitive study on unsupervised anomaly detection with an autoencoder in emergency head CT volumes

    Science.gov (United States)

    Sato, Daisuke; Hanaoka, Shouhei; Nomura, Yukihiro; Takenaga, Tomomi; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-02-01

    Purpose: The target disorders of emergency head CT are wide-ranging. Therefore, people working in an emergency department desire a computer-aided detection system for general disorders. In this study, we proposed an unsupervised anomaly detection method in emergency head CT using an autoencoder and evaluated the anomaly detection performance of our method in emergency head CT. Methods: We used a 3D convolutional autoencoder (3D-CAE), which contains 11 layers in the convolution block and 6 layers in the deconvolution block. In the training phase, we trained the 3D-CAE using 10,000 3D patches extracted from 50 normal cases. In the test phase, we calculated abnormalities of each voxel in 38 emergency head CT volumes (22 abnormal cases and 16 normal cases) for evaluation and evaluated the likelihood of lesion existence. Results: Our method achieved a sensitivity of 68% and a specificity of 88%, with an area under the curve of the receiver operating characteristic curve of 0.87. It shows that this method has a moderate accuracy to distinguish normal CT cases to abnormal ones. Conclusion: Our method has potentialities for anomaly detection in emergency head CT.

  10. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  11. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  12. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    International Nuclear Information System (INIS)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille; Liozon, Eric; Ly, Kim Heang; Lambert, Marc; Aide, Nicolas; Manrique, Alain

    2017-01-01

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  13. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    Energy Technology Data Exchange (ETDEWEB)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille [Caen University Hospital, Department of Internal Medicine, Caen (France); Liozon, Eric; Ly, Kim Heang [Limoges University Hospital, Department of Internal Medicine, Limoges (France); Lambert, Marc [Lille University Hospital, Department of Internal Medicine, Lille (France); Aide, Nicolas [Caen University Hospital, Department of Nuclear Medicine, Caen (France); INSERM U1086 ' ' ANTICIPE' ' , Francois Baclesse Cancer Centre, Caen (France); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Caen (France); Normandy University, Caen (France)

    2017-12-15

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  14. Differentiation of adrenal adenomas from nonadenomas using CT histogram analysis method: A prospective study

    International Nuclear Information System (INIS)

    Halefoglu, Ahmet Mesrur; Bas, Nagihan; Yasar, Ahmet; Basak, Muzaffer

    2010-01-01

    Objective: The objective of our study was to prospectively evaluate the effectiveness of computed tomography (CT) histogram analysis method in the differentiation of benign and malignant adrenal masses. Materials and Methods: Between March 2007 and June 2008, 94 patients (46 males, 48 females, age range: 30-79 years, mean age: 57.7 years) with 113 adrenal masses (mean diameter: 3.03 cm, range: 1.07-8.02 cm) were prospectively evaluated. These included 66 adenomas, 45 metastases and 2 pheochromocytomas. Histogram analysis method was performed using a circular region of interest (ROI) and mean attenuation, total number of pixels, number of negative pixels and subsequent percentage of negative pixels were detected on both unenhanced and delayed contrast-enhanced CT images for each adrenal mass. A mean attenuation threshold of 10 Hounsfield unit (HU) for unenhanced CT and 5% and 10% negative pixel thresholds for both unenhanced and delayed contrast-enhanced CT were calculated by a consensus of at least two reviewers and the correlation between mean attenuation and percentage of negative pixels was determined. Final diagnoses were based on imaging follow-up of minimum 6 months, biopsy, surgery and adrenal washout study. Results: 51 of 66 adenomas (77.3%) showed attenuation values of ≤10 HU and 15 (22.7%) adenomas showed more than 10 HU on unenhanced CT. All of these adenomas contained negative pixels on unenhanced CT. Eight of 66 (12.1%) adenomas showed a mean attenuation value of ≤10 HU on delayed contrast-enhanced scans and 45 adenomas (68.2%) persisted on containing negative pixels. All metastases had an attenuation value of greater than 10 HU on unenhanced CT images. 21 of 45 (46.6%) metastases contained negative pixels on unenhanced images but only seven metastases (15.5%) had negative pixels on delayed contrast-enhanced images. Two pheochromocytomas had negative pixels on both unenhanced and delayed contrast-enhanced CT images. Increase in the percentage of

  15. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  16. Illustrating ontogenetic change in the dentition of the Nile monitor lizard, Varanus niloticus: a case study in the application of geometric morphometric methods for the quantification of shape-size heterodonty.

    Science.gov (United States)

    D'Amore, Domenic C

    2015-05-01

    Many recent attempts have been made to quantify heterodonty in non-mammalian vertebrates, but the majority of these are limited to Euclidian measurements. One taxon frequently investigated is Varanus niloticus, the Nile monitor. Juveniles possess elongate, pointed teeth (caniniform) along the entirety of the dental arcade, whereas adults develop large, bulbous distal teeth (molariform). The purpose of this study was to present a geometric morphometric method to quantify V. niloticus heterodonty through ontogeny that may be applied to other non-mammalian taxa. Data were collected from the entire tooth row of 19 dry skull specimens. A semilandmark analysis was conducted on the outline of the photographed teeth, and size and shape were derived. Width was also measured with calipers. From these measures, sample ranges and allometric functions were created using multivariate statistical analyses for each tooth position separately, as well as overall measures of heterodonty for each specimen based on morphological disparity. The results confirm and expand upon previous studies, showing measurable shape-size heterodonty in the species with significant differences at each tooth position. Tooth size increases with body size at most positions, and the allometric coefficient increases at more distal positions. Width shows a dramatic increase at the distal positions with ontogeny, often displaying pronounced positive allometry. Dental shape varied in two noticeable ways, with the first composing the vast majority of shape variance: (i) caniniformy vs. molariformy and (ii) mesially leaning, 'rounded' apices vs. distally leaning, 'pointed' apices. The latter was twice as influential in the mandible, a consequence of host bone shape. Mesial teeth show no significant shape change with growth, whereas distal teeth change significantly due primarily to an increase in molariformy. Overall, heterodonty increases with body size concerning both tooth size and shape, but shape

  17. [Study of patients with prolonged fever with (18)F-FDG PET/CT].

    Science.gov (United States)

    Moragas, M; Cozar, M Puig; Buxeda, M; Soler, M; Riera, E; García, J R

    2015-01-01

    To review the findings on (18)F-FDG PET-CT in patients with fever of unknown origin lasting more than 7 days. This retrospective descriptive observational study included 93 (18)F-FDG PET-CT studies to detect a fever-causing focus done at three nuclear medicine centers from October 2006 through February 2014. A nuclear medicine specialist and a radiologist reviewed the images for foci of pathological uptake; another specialist's opinion resolved discrepancies. The findings on (18)F-FDG PET-CT studies were checked against clinical and/or histological findings. Abnormal (18)F-FDG uptake on PET-CT that could explain the cause of the fever was found in 52 (56%) of the 93 studies, and the cause of the fever was confirmed in 50 of these 52 studies. In the 50 cases in which the cause of the fever was confirmed, infection was the most common cause (54%), followed by noninfectious inflammatory disease (28%) and tumors (18%). (18)F-FDG PET-CT is useful in diagnosing the cause of prolonged febrile illness, so it might be practical to use it earlier in the diagnostic process. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  18. A study of effective sequences on micro-CT in the dent-maxillo-facial region

    International Nuclear Information System (INIS)

    Kato, Masataka; Mori, Shintaro; Sakayanagi, Masashi; Fujita, Yuzo; Kaneda, Takashi

    2005-01-01

    Microfocus computed tomography (micro-CT) using cone-beam scan is becoming widely used for various studies of oral structures. However, this machine has not been used to evaluate the effective parameters for two-dimensional (2D) or three-dimensional (3D) images. This study evaluated the effective parameters of micro-CT for 2D or 3D images of oral hard tissue structures. We evaluated the CT value of 5 human teeth (upper first molars) to determine suitable CT value examined according to several X-ray parameters using conformal radiotherapy (CRT) on a work station. CT information from the specimens was obtained using a micro-CT (Toscaner-31300 μ, Toshiba ITC), under the conditions of tube voltage of 75 kV, tube current of 120 μA, 100∼1600 views, the number of times of addition, 512 x 512 pixel matrix, and 0.2 slice thickness. We made 3D-reconstruction images from the micro-CT data. Three-dimensional reconstruction was performed using 2D images processed by the volume-rendering method using 3D-reconstruction software (TRI/3D BON, RATOC system engineering). Then, we evaluate the 3D tooth images. In the assessment of images, three dental radiologists evaluated several 3D tooth images using 3D-reconstruction images. Each image was scored on a five-level scale by Scheffe one-pair comparison method as follows: 5: much easier to evaluate, 4: easier to evaluate, 3: equivalent, 2: harder to evaluate, 1: much harder to evaluate. In scoring, each of the three dental radiologists made an individual assessment, and when differences among individual scores occurred, the score was ultimately assigned by consensus among the three individuals. Statistical analysis of the scores assigned by the three dental radiologists as described above was carried out using Stat View-J 5.0 (Abacus Concepts, Inc, USA) statistical software and Tukey-Kramer multiple-comparison testing. The optimal CT value for evaluating the human tooth by micro-CT is 600 on 2D images. On 3D images, the optimal

  19. Morphometric measurement of submucosal thickness in areas of fat deposition in the terminal ileum and colonic sections, with correlation with body mass index, weight and age: a male autopsy study.

    Science.gov (United States)

    Mesa, Hector; Drawz, Sarah; Dykoski, Richard; Manivel, Juan Carlos

    2015-10-01

    An increased amount of submucosal (SM) fat in the colon on imaging is considered to be characteristic of inflammatory bowel disease (IBD); however, a recent study in patients without IBD reported a correlation between colonic SM fat deposition and body weight (BW). The aim of this study was to perform a morphometric investigation of SM thickness in areas of fat deposition in the terminal ileum (TI), ileocaecal valve (ICV), and colonic sections, to determine whether there are variations by site, and whether it shows a correlation with BW, body mass index (BMI), or age. Representative samples of TI, ICV and colonic sections were collected prospectively from 115 autopsy cases without IBD. All of the study subjects were male (Veterans Hospital). SM thickness was measured in areas of fat deposition. Correlation analysis was performed between SM thickness and BW, BMI, and age. Fat deposition was common; however, with the exception of the ICV, it was neither consistent nor prominent, and it did not show a statistical correlation with BW, BMI, or age. SM fat deposition is common but not uniform or conspicuous in the TI or colon. In contrast to extravisceral intra-abdominal fat, it does not show a correlation with BW or BMI, and is not associated with ageing. As all study subjects were male, gender-dependent variability cannot be excluded. © 2015 John Wiley & Sons Ltd.

  20. Periventricular hypodensity in communicating hydrocephalus studied by metrizamide CT cisternography

    International Nuclear Information System (INIS)

    Hiratsuka, Hideo; Okada, Kodai; Takasato, Yoshio; Inaba, Yutaka; Tsuyumu, Matsutaira.

    1979-01-01

    Modification of periventricular hypodensity in suspected communicating hydrocephalus was investigated by metrizamide CT cisternography. Six to eight ml of metrizamide isotonic solution with a concentration of 170 mgI/ml was given through lumbar puncture and scanning was conducted 1, 3, 6, 24 and 48 hrs after injection. In addition to visual analysis of images, mean value and standard deviation were calculated for Hounsfield units of the regions of interest at the anterolateral angle of frontal horn and the time courses of the attenuation values were statistically compared to each other at each scanning time. The results were classified into four groups: 1) periventricular low density zone with gradual penetration of metrizamide therein; 2) periventricular low density zone without penetration of metrizamide therein; 3) minimal periventricular low density zone with minimal metrizamide penetration; and 4) no periventricular low density zone and no penetration of metrizamide. The presence of a periventricular low density zone with increase of the density after ventricular reflux of metrizamide would be an important criterion for CSF shunting operation in normal pressure hydrocephalus or communicating hydrocephalus. (author)

  1. Labyrinthine otosclerosis studied by high-resolution CT

    International Nuclear Information System (INIS)

    Funai, Hiroaki; Horiuchi, Yasuharu; Yano, Jun; Ushijima, Tatujiro; Iinuma, Toshitaka; Oyama, Kazuyuki

    1986-01-01

    Labyrinthine lesions of 10 patients (20 ears) with surgically confirmed otosclerosis were investigated by means of high-resolution CT (HRCT). All ears were scaned in horizontal plane and a slice thickness of 2.0 mm was used to avoid the excessive loss of sharpness by partial volume averaging. HRCTs of 14 normal ears and 18 ears with otitis media were analyzed as controls. (1) Three patients (6 ears) demonstrated lucent zones around the cochleae. In one of 3 cases the zone extended to involve the vestibule and the semicircular canals. (2) The definitive lucent zone was not observed in the control scans. (3) The clinical data of the 3 patients whose HRCTs demonstrated the lucent zones were compared with the other 7 patients with clinical otosclerosis. Three patients showed no distinctive features regarding to age, sex, Schwartze sign and the operative findings. (4) Average bone conduction loss was significantly greater in ears with lucent zones than those without the lucent zones. Serial audiograms revealed progressive hearing impairment in 3 ears of 2 patients with the definitive lucent zone. The present report confirmed that foci of demineralization (otospongiotic lesion) in the labyrinthine capsule were imaged by the HRCT as lucent areas. HRCT provides a reproducible and reliable mean of diagnosis for the labyrinthine otosclerosis. (author)

  2. Epidemiology Study on P53 (Rs1614984 C>T Mutation in Cigarette Smokers

    Directory of Open Access Journals (Sweden)

    Dilshad Ahmad

    2017-05-01

    Full Text Available ABSTRACT Epidemiology data have established that smoking is a prime threat for the cancers, largely lung cancer. Single-nucleotide polymorphisms (SNPs,P53 SNPs have been found to be associated with the predisposition of different cancers. Their decreased expression is reported in breast and lung cancer patients. p53 (rs1614984 had been reported to be linked with the SNPs found associated with breast cancer. The primary aim of this study to determine the association of p53 variant rs1614984 with the cigarette smokers and smoking related cancers in smokers. Among the smokers, 38% were found with CC genotype, 55% were heterozygous CT and 7% were TT, respectively. The homozygous TT genotype was seen in lower percentage of smokers (7% when compared to non-smokers (8% whereas; Significant difference was not observed when encompassed by CC, CT and TT genotypes (χ2 = 4.892, p=0.087. However, CC vs CT genotype showed a significant difference between smokers and non-smokers (p=0.031, OR 1.447 (1.035-2.025 and the dominant model CC vs CT+TT was also significantly different among smoker and non-smokers (p=0.047, OR 1.39 (1.004-1.924. Furthermore, smokers are at the risk of developing variety of diseases including lung cancer. Our finding suggests a higher percentage of heterozygous CT genotype in smokers when compared to non-smokers. Therefore, this finding gives a clue that the transition mutation of C>T (rs1614984 may leads to the lung diseases including cancer in smokers. However, there will be a need of more extensive and elaborated study to set down the aspect of p53(rs1614984 C>T in lung cancer among smokers.

  3. Relationship between the thickness of the renal cortex and age: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian

    2004-01-01

    Objective: To study the relationship between the renal cortical thickness and age, and to establish the range of the normal renal cortex thickness by using CT measurement in different age groups so as to obtain a best age-related and practicable method for clinical measurement. Methods: (1) the accuracy of measuring renal cortical thickness by CT was evaluated: 18 kidney resected due to renal neoplasm were studied and the cortical thickness of the normal part of these specimens was assessed. The difference between the renal cortical thickness of specimens and preoperative measurements of renal cortex of the same patient by contrast enhanced CT was analyzed statistically. (2) 120 patients without history of renal disease or long term usage of potentially renal toxic drugs or history of hypertension were examined by CT with indication (s) other than renal disease. All the patients were divided into 20-40, 41-60, and 61-80 year-old groups. The renal cortical and parenchymal thickness and renal size were measured in three CT sections. The difference of the measurements among the three groups and their relationship to age was analyzed statistically. Results: There was no significant difference between the renal cortical thickness measured by enhanced spiral CT and measured in renal specimens (t=0.80, P=0.43). The renal cortical thickness in three groups was 0.73 cm, 0.65 cm, and 0.53 cm, respectively, and the differences among the three groups were significant (F=93.430, P 0.05). Conclusion: The measurement of the renal cortical thickness with enhanced spiral CT was reliable and was a sensitive method in investigating the morphologic changes of the kidney. The renal cortical thickness of normal kidney diminishes with age, but the change of the ratio of thickness of renal cortex to renal parenchyma with age was not significant

  4. A study of requested CT head examinations and their positive yield rate

    International Nuclear Information System (INIS)

    Coakley, K.S.

    2004-01-01

    Full text: Requests for CT examinations are ever increasing, partly due to the excellent clinical information they can provide for patient management and partly due to a perceived need for 'evidence' that everything has been done to diagnose a patient correctly. This has led to many CT examinations being done on patients where many of the radiology community does not necessarily feel CT will yield a positive finding, i.e. in their eyes - a possible unjustified use of radiation. To determine whether this was in fact true, or merely a perception, a study was performed by medical imaging and physics staff at the Royal Brisbane Hospital to determine statistics of positive yield for CT head exams. 600 CT head examinations from the Emergency Department at the Royal Brisbane Hospital were retrospectively examined and their findings were tabulated under various clinical categories to determine positive yield statistics. These categories were also tabulated with the radiologists advice as to whether they would have expected a positive finding. For several categories the positive yield for CT head exams was so low as to be considered negligible. Other categories, although low were still considered significant. These will be presented to the emergency department along with a suggested protocol for requesting CT head exams. It was unfortunate that this study had to be performed to prove to clinical staff that medical imaging staff members do in general have an excellent idea of what will show up in an x-ray and what will not! However, it was useful to be able to categorise 'positive yield' statistics into such specific classes. The next step is to try and communicate these findings to staff to create more trust and better communication between departments. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  5. Child gluteal aggressive fibromatosis: a correlative study of CT findings and pathology

    International Nuclear Information System (INIS)

    Fan Miao; Li Ziping; Meng Quanfei; Guo Yan; Ye Bingbing; Xiao Gang

    2005-01-01

    Objective: To evaluate CT imaging in the diagnosis of child gluteal aggressive fibromatosis. Methods: CT manifestations of child gluteal aggressive fibromatosis were retrospectively analyzed. In total 7 males and 1 female, 2 to 11 years old, were enrolled in study. All cases had been confirmed by surgery and pathology. CT findings were correlatively studied with pathology. Results: Lesions located on the left side were noted in 7 cases, and a lesion located on right side was seen in the rest 1 cam The lesions were elliptical or lobulated on CT images. Three tumors originated from solitary muscle and multiple muscles were involved in other 5 cases. Tumors were well demarcated. Invasion to the adjacent structure was shown in 7 cases. All tumors were homogeneous in density in non-enhanced scan. Compared to the muscles in the same section, 5 tumors were iso -density and 3 tumors were hypo-density. Inside the lesions no hemorrhage, necrosis, cystic degeneration and calcification was revealed. After contrast medium was administrated, iso-dense and homogeneous enhancement as the adjacent muscles was seen in 1 tumor and apparent enhancement were demonstrated in 7 tumors. Seven tumors tended to grow along the longitudinal axis of muscles and infiltrated into fascial space. Atrophy resulting from compression was shown in the adjacent muscles in 6 cases. The major clinical manifestation was limp. Gluteal aggressive fibromatosis was confirmed by pathology in all cases. Conclusion: There are characteristics of child gluteal aggressive fibromatosis in age of onset, gender of the patients, site of the lesion and CT findings as well. CT manifestations were consistent with pathology. CT imaging is helpful in initial diagnosis and differential diagnosis, as well as in assessing the expansion of the tumor and involvement of the adjacent structures. (authors)

  6. CT in the study of thoracic-pulmonary complications after liver transplantation

    International Nuclear Information System (INIS)

    Robiati, S.; Veltri, A.; Martina, M. C.; Gariazzo, G.; Gandini, G.; Cerutti, E.; Ottobrelli, A.

    2000-01-01

    In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) examinations had been performed with conventional CT scanning (100 with i.v. contrast agent and 33 without) and 19/152 (12.5%) with HRCT. Twenty of 152 (13.2%) examinations, in 16 patients were normal; in the other 84 patients, 132/152 (86.8%) CT/HRCT studies showed 247 pathological findings (99 pleural effusions, 3 pericardial effusions, 62 cases of atelectasis, 1 pulmonary calcification, 70 suspected inflammatory parenchymal consolidations, 64 of them alveolar and 6 interstitial, 4 cases of interstitial edema and finally 8 neoplastic infiltrates). Correlated with clinical data, CT findings are very useful in detailing clinical-radiographic screening findings, despite the limitations in typifying pleural effusions, in differentiating atelectasis from inflammatory parenchymal consolidations and in assessing pneumonia etiology. Also, despite its high sensitivity (94.1%) and specificity (92.8%), CT was not accurate enough in the differential diagnosis of pneumonia. History data were necessary to characterize the histology of

  7. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  8. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  9. Head holder using negative pressure bag packed with plastic beads in xenon CT CBF study

    International Nuclear Information System (INIS)

    Araki, Yuzo; Sakai, Noboru

    2003-01-01

    Employing analysis of cerebral blood flow (CBF) confidence maps, we investigated the usefulness of a head holder using a negative pressure bag packed with plastic beads in a xenon CT CBF study. A total of 272 consecutive patients for the CBF study were enrolled and classified into 3 groups: 88 patients with a negative pressure bag (M group), 87 patients with an air pillow (A group), and 97 patients with a sponge pillow (S group). The degree of effect of head movements on the CBF measurement in each patient was expressed as a confidence value (mean of the confidence values at one CT slice). The mean of confidence value in the M group (0.461) was statistically lower than that in the A group (0.866) and that in the S group (1.043). These findings showed that the head holder described here was useful for obtaining CBF maps of high quality in a xenon CT CBF study. (author)

  10. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  11. Repeated CT studies of a patient with herpes simplex encephalitis during his entire clinical course

    International Nuclear Information System (INIS)

    Shiraishi, Masahiro; Fukui, Keiji; Takeda, Sadanori; Sadamoto, Kazuhiko; Kimura, Hideki; Sakaki, Saburo.

    1985-01-01

    We encountered a patient with herpes simplex encephalitis whose cerebral lesions were studied by repeated CT scannings during his entire clinical course. The purpose of this paper is to report the earliest lesions of the brain as revealed by CT scans. A 63-year-old man was admitted to our clinic complaining of headache, nausea, fever, and disorientation. On admission, a physical examination showed a high fever, while a neurological examination revealed a stiff neck, a positive Kernig's sign, and disorientation. Laboratory examinations revealed a pleocytosis of the cerebrospinal fluid. Electroencephalograms showed the so-called ''periodic sharp-and-slow-waves complex''. The complement fixation titer for herpes simplex virus was x32 in the serum and x128 in the cerebrospinal fluid, suggesting the diagnosis of herpes simplex encephalitis. We treated him with adenine arabinoside and gamma-globulin, but the patient did not recover; rather, he died of pneumonia and gastrointestinal bleeding three months later. Plain CT scans taken on the 12th day after the onset revealed a low-density area with signs of a slight mass in the region from the right island of Reil to the right uncus. Contrast-enhanced CT scans revealed an irregular enhancement in the low-density area. CT scans taken on the 19th day after the onset showed an extensive low-density area with a streak-like enhancement in the right temporal lobe, which is in aggreement with the findings reported by others as characteristic CT findings for herpes simplex encephalitis. In order to make an early diagnosis of a patient, we should pay attention to a low-density area with an irregular contrast enhancement in the region from the island of Reil to the uncus on a CT scan. (author)

  12. Effect of clinical information in brain CT scan interpretation : a blinded double crossover study

    International Nuclear Information System (INIS)

    Zhianpour, M.; Janghorbani, M.

    2004-01-01

    Errors and variations in interpretation can happen in clinical imaging. Few studies have examined the biased effect of clinical information on reporting of brain CT scans. In a blinded double crossover design, we studied whether three radiologists were biased by clinical information when making CT scan diagnosis of the brain. Three consultant radiologists in three rounds with at least a one month interval assessed 100 consecutive cases of brain CT scan. In the first round, clinical information was not available and 100 films without clinical information were given to radiologists. In the second round, the same 100 films were given and true clinical information was available. In the third round, the same 100 films were given and false clinical information was allocated. In 180 cases (60%) the evaluation resulted in the same diagnosis on all three occasions (95% confidence interval (CI): 54.5, 65.5), whereas 120(40%; 95% CI:34.5, 45.5) sets were evaluated differently. 48 cases (16%; 95% CI:11.9,20.1) had discordant evaluation with true and 33 (11%; 95% CI:7.5, 14.5) with false clinical information. Discordance without and with true and false clinical information was 39 (13%; 95% CI:9.2, 16.8). Correct clinical information improves the brain CT report, while the report became less accurate false clinical information was allocated. These results indicate that radiologists are biased by clinical information when reporting brian CT scans

  13. Evaluation of radiation dose in pediatric head CT examination: a phantom study

    Science.gov (United States)

    Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, Ahmad Taufek Abdul

    2018-01-01

    The aim of this study was to evaluate the radiation dose in pediatric head Computed Tomography examination. It was reported that decreasing tube voltage in CT examination can reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The average dose was 2.60 mGy at CT imaging parameters of 80 kV and 10 - 30 mAs. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

  14. Imaging benign pathology and variants with uptake in 68ga-Dotatate PET/CT studies

    International Nuclear Information System (INIS)

    Servente, L.; Bianco, C.; Gigirey, V.; Alonso, O.

    2017-01-01

    Purpose: To evaluate the physiological, anatomical variants and benign lesions in positron emission computed tomography (PET/CT) studies with 68Ga-DOTATATE.Materials and methods: We retrospectively reviewed PET/CT reports scanned with 68Ga-DOTATATE and selected those that contained words in the report related to anatomical, physiological variants and benign tumors. The degree of 68Ga-DOTATATE uptake was evaluated qualitatively and quantitatively by measuring the standarized uptake max value (SUVmax value). The anatomical location, SUVmax value and morphological CT image findings were recorded. All cases had clinical and imaging follow-up. Results: From a total of 772 PET/CT reports, 28 patients were obtained with 33 benign variants or tumors, 14 females and 14 males with a median age of 63 years. Uptake patterns were classified into four groups: anatomic and physiological variants (15), dependent on osteoblastic activity (4), dependent on inflammatory activity (10) and non-neuro-endocrine benign tumors (4).Discussion: Somatostatin receptors are overexpressed not only in the neuroendocrine system but also in other tissues. Physiological, anatomical variants and benign tumors expressing these receptors may be misleading. In the present work the frequency of this finding is 5.1%.Conclusion: Physiological variants and benign lesions (tumor and inflammatory) can accumulate 68Ga-DOTATATE since their tissues can express somatostatin receptors. The semiologic analysis of the tomographic component of this hybrid method enhances the diagnostic efficacy, optimizing PET/CT study performance. (authors) [es

  15. [Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3 Tesla magnetic resonance images].

    Science.gov (United States)

    Alberich-Bayarri, A; Martí-Bonmatí, L; Sanz-Requena, R; Sánchez-González, J; Hervás Briz, V; García-Martí, G; Pérez, M Á

    2014-01-01

    We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT). We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2D fractal dimension (D(2D)), the 3D fractal dimension (D(3D)), and the elastic module in the three spatial directions (Ex, Ey and Ez). The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (μCT) was high, with errors less than 15% for BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z. Our experimental results in animals confirm that the parameters of BV/TV, D(2D), D(3D), and E(app)x, E(app)y and E(app)z obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  16. Accuracy and efficiency of radiologists reporting CT studies from a multiscreen electronic workstation

    International Nuclear Information System (INIS)

    Foley, W.D.; Lawson, T.L.; Erickson, S.J.

    1988-01-01

    This paper describes a limited picture archiving communication system linking, a via fiber optic cable, two computed tomographic (CT) scanners, and a double-screen (1,000-line monitors) display station with a 600-megabyte image memory evaluated for accuracy and efficiency in the generation of a radiology report. Twenty preselected CT studies (an average of 30 images per study, ten with prior examination for comparison) in cases with pathologically or clinically proved diagnoses were read by five radiologists, in random order, from both the electronic display console and conventional multiformat images. All cases were reread after 1-month interval in a different random order viewing sequence and the opposite viewing modality

  17. CT study of the ethmoid labyrinth: technique of examination and normal anatomy

    International Nuclear Information System (INIS)

    Duvoisin, B.; Schnyder, P.; Chapuis, L.; Agrifoglio, A.; Krayenbuehl, M.

    1990-01-01

    These recent years, conservative endoscopic surgical treatments for inflammatory ethmoid disease have gained popularity and prompted a need for an optimal preoperative radiologic study. For this purpose, the routinely used axial and coronal CT slices are not sufficient. In our Center, the ethmoid labyrinth is studied with planes determined by the axis of drainage of all ethmoid cells. This axis corresponds to the axis of the nasofrontal duct, which is approximately angulated 50 sup(0) cephalad relative to the canto-meatal line (CML). We perform routinely CT sections in the planes CML sup(+) and CML -40 (which are respectively parallel and perpendicular to the nasofrontal duct axis). The normal anatomy of the ethmoid labyrinth is illustrated by sequential CT slices in these two planes. (author)

  18. Comparative study of patellar subluxation syndrome and normal group using axial radiography and CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitagawa, Mamoru; Tomonaga, Kunio; Egawa, Tadashi; Nakamura, Yasushi; Gotoh, Shoji; Mihara, Shigeru (Nagasaki Municipal Hospital (Japan))

    1989-10-01

    A comparative study was conducted on the 20 knees of 10 females with normal knee joints (age, 22-35 years) and on 7 knees of 7 patients with subluxation syndrome (age, 15-24 years), using axial radiography and CT. In axial radiography where the angle of knee flexion was 30 deg or 60 deg, no significant difference was recognized between the two groups with respect to tilting angle, patellofemoral angle, congruence angle and lateral shift. However, a significant difference was found using CT. Thus, CT was considered useful for diagnosis. Because of these results, all 7 cases underwent surgery for detachment of the lateral side and tightening of the medial side. Three cases underwent shifting of the tibial tuberosity to the anteromedial side, resulting in a favourable outcome. Here, we report the study. (author).

  19. Comparative study of patellar subluxation syndrome and normal group using axial radiography and CT

    International Nuclear Information System (INIS)

    Kitagawa, Mamoru; Tomonaga, Kunio; Egawa, Tadashi; Nakamura, Yasushi; Gotoh, Shoji; Mihara, Shigeru

    1989-01-01

    A comparative study was conducted on the 20 knees of 10 females with normal knee joints (age, 22-35 years) and on 7 knees of 7 patients with subluxation syndrome (age, 15-24 years), using axial radiography and CT. In axial radiography where the angle of knee flexion was 30 deg or 60 deg, no significant difference was recognized between the two groups with respect to tilting angle, patellofemoral angle, congruence angle and lateral shift. However, a significant difference was found using CT. Thus, CT was considered useful for diagnosis. Because of these results, all 7 cases underwent surgery for detachment of the lateral side and tightening of the medial side. Three cases underwent shifting of the tibial tuberosity to the anteromedial side, resulting in a favourable outcome. Here, we report the study. (author)

  20. The oblique occipital sinus: anatomical study using bone subtraction 3D CT venography.

    Science.gov (United States)

    Shin, Hwa Seon; Choi, Dae Seob; Baek, Hye Jin; Choi, Ho Cheol; Choi, Hye Young; Park, Mi Jung; Kim, Ji Eun; Han, Jeong Yeol; Park, SungEun

    2017-06-01

    An occipital sinus draining into the sigmoid sinus has been termed the oblique occipital sinus (OOS). The frequency, anatomical features, patterns, and relationship with the transverse sinus of the oblique occipital sinus were analyzed in this study. The study included 1805 patients who underwent brain CT angiography during a 3-year period from 2013 to 2015. CT examinations were performed using a 64-slice MDCT system. The OOS was identified in 41 patients (2.3%). There were many anatomical variations in the oblique occipital sinuses. A hypoplastic or aplastic TS was seen in 31 (75.6%) of the 41 patients with OOS. Many anatomical variations in the oblique occipital sinus can be seen on CT venography. Some OOSs function as the main drainage route of the intracranial veins instead of the TS. Thus, careful examination is essential for preoperative evaluation in posterior fossa lesions.

  1. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    Science.gov (United States)

    Akça, Kivanç; Chang, Ting-Ling; Tekdemir, Ibrahim; Fanuscu, Mete I

    2006-08-01

    The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and mandible of a human cadaver. Experiments were undertaken to quantify initial implant stability and bone micro-morphology. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to determine initial intraosseous implant stability. For quantification of relative bone volume and micro-architecture, sectioned implant-bone and bone core specimens of each implant placement site were consecutively scanned and trabecular bone was analyzed in a micro-computed tomography (micro-CT) unit. Experimental outcomes were evaluated for correlations among implant designs, initial intraosseous implant stability and bone micro-structural parameters. ITVs correlated higher with bone volume fraction (BV/TV) than ISQs, at 88.1% and 68.9% levels, respectively. Correlations between ITVs and micro-morphometric parameters were significant at the 95% confidence level (Pimplant designs used were not significant at the 95% confidence level (P>0.05). Bone micro-morphology has a prevailing effect over implant design on intraosseus initial implant stability, and ITV is more sensitive in terms of revealing biomechanical properties at the bone-implant interface in comparison with ISQ.

  2. MORPHOMETRIC ANALYSES OF THE PARACENTRAL LOBE

    Directory of Open Access Journals (Sweden)

    Moacyr Oliveira Neto

    2014-03-01

    Full Text Available ntroduction:There are no studies that evaluate measurements of the distances between the grooves that delimit the Paracentral Lobule (PCL in the literature. This study seeks to contribute to the knowledge regarding the anatomy of the PCL, conducting an analysis of morphometric measurements in this region and its correlation with the paracentral sulcus, marginal branch of the cingulate and central sulcus. Methods:42 hemispheres were evaluated, 20 were right and 22 left. Using digital caliper Dc - 6 Western ®, measurements of the size of PCL in the sagittal axis and coronal axis were made, in addition to measures of the Central Sulcus to the Paracentral Sulcus (motor area and Central Sulcus to Marginal Branch of the Cingulate Sulcus (somesthetic area, comparing the prevalence of each of these lengths between hemispheres. Results:The average length between the Paracentral Sulcus and the Central Sulcus was 24.49 cm(14.2 to 38.6 cm in the right hemisphere and 25.50 cm(11.7 to 37.0 cm in the left. As between the Central Sulcus and the Marginal Branch of the Cingulate Sulcus was in average 10.03 cm(2.6 to 22.7 cm in the right and in the left PCL 9.17cm(2.6 to 22.7 cm. In the right hemisphere, 19 samples(86,4% presented greater motor area than somesthetic and, in the left hemisphere, 19 samples(95% had greater motor area. Conclusion:The motor area showed prevalence in relation to the sensory area in the analysis of the two hemispheres, while the comparison of other measures between the two hemispheres showed no significance.

  3. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive: the APACH1 study.

    Science.gov (United States)

    Quak, Elske; Blanchard, David; Houdu, Benjamin; Le Roux, Yannick; Ciappuccini, Renaud; Lireux, Barbara; de Raucourt, Dominique; Grellard, Jean-Michel; Licaj, Idlir; Bardet, Stéphane; Reznik, Yves; Clarisse, Bénédicte; Aide, Nicolas

    2018-04-01

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients

  4. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive. The APACH1 study

    Energy Technology Data Exchange (ETDEWEB)

    Quak, Elske; Lireux, Barbara; Bardet, Stephane [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); Blanchard, David; Raucourt, Dominique de [Francois Baclesse Cancer Centre, Department of Head and Neck Surgery, Caen (France); Houdu, Benjamin [University Hospital, Department of Nuclear Medicine, Caen (France); Le Roux, Yannick [University Hospital, Department of General and Endocrine Surgery, Caen (France); Ciappuccini, Renaud [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); Caen University, INSERM 1086 ANTICIPE, Caen (France); Grellard, Jean-Michel; Licaj, Idlir; Clarisse, Benedicte [Francois Baclesse Cancer Centre, Department of Clinical Research, Caen (France); Reznik, Yves [University Hospital, Department of Endocrinology, Caen (France); Aide, Nicolas [Francois Baclesse Cancer Centre, Department of Nuclear Medicine and Thyroid Unit, Caen (France); University Hospital, Department of Nuclear Medicine, Caen (France); Caen University, INSERM 1086 ANTICIPE, Caen (France)

    2018-04-15

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary

  5. F18-choline PET/CT guided surgery in primary hyperparathyroidism when ultrasound and MIBI SPECT/CT are negative or inconclusive. The APACH1 study

    International Nuclear Information System (INIS)

    Quak, Elske; Lireux, Barbara; Bardet, Stephane; Blanchard, David; Raucourt, Dominique de; Houdu, Benjamin; Le Roux, Yannick; Ciappuccini, Renaud; Grellard, Jean-Michel; Licaj, Idlir; Clarisse, Benedicte; Reznik, Yves; Aide, Nicolas

    2018-01-01

    To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary

  6. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    International Nuclear Information System (INIS)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease. (author)

  7. The evaluation study of helical CT for hepatocellular carcinoma with microwave coagulation treatment

    International Nuclear Information System (INIS)

    Zheng Keguo; Xu Dasheng; Xie Xiaoyan; Peng Zhenpeng

    2002-01-01

    Objective: To study the helical CT signs of the hepatocellular carcinoma (HCC) after percutaneous microwave coagulation therapy (PMCT) and to evaluate the correlation between the helical CT signs and the therapeutic effect of HCC. Methods: The helical CT signs were analyzed in 22 cases with 26 lesions of the hepatocellular carcinoma that were treated with PMCT under ultrasonic guidance. Results: In 21 lesions, no enhancement was detected in the lesion border or inside the lesion at hepatic arterial phase (HAP) and portal venous phase (PVP). In 7 lesions, the slight or marked patchy enhancement was revealed in the surrounding liver of the lesions in HAP. In 5 lesions, nodular enhancement was found in the lesion border or inside the lesion in HAP. Conclusion: The dual-phase helical CT might be accurate in judging the therapeutic effect of HCC after PMCT. If no enhancement was showed in the lesions in the dual-phase helical CT, it indicated that no tumor survived. If slight or marked patchy pattern enhancement was revealed in the surrounding liver of the lesions in HAP, it was a normal reaction after PMCT. If nodular enhancement was found in the lesion border or inside the lesion in HAP, it indicated that the tumor partially survived

  8. Studies on evaluation of staging of cancer of the uterine cervix by means of CT

    Energy Technology Data Exchange (ETDEWEB)

    Kakizaki, D

    1987-03-01

    The present study was undertaken to evaluate the stage classification (FIGO) by using CT in 50 cases with cancer of the uterine cervix in which the final stage had been diagnosed. An accurate diagnosis was obtained in 6 of 14 Ib cases, 14 of 21 IIa cases, 5 of 6 IIb cases, 2 of 3 IIIa cases, 3 of 3 IIIb cases and 3 of 3 IVa cases, for a total of 33 of 50 (66 %). The diagnostic rate for Ib and IIa staging was 57 %, while that for IIb or more was 87 %, but the accuracy rate in IIIb and IVa was 100 %. As the equipment, a high resolutional GE 9800 CT using a special technique was employed. Employing special pretreatment for the patient, it became possible to accurately grasp the pelvic condition of the patients. CT evaluation was related to the extent of the cervical cancer and the presence of infiltration into the vaginal wall. According to a 4-stage classification of the CT image, the extent of infiltration to surrounding parametrium and the bladder was determined. As a result, the sensitivity for evaluating invasion into surrounding tissue raised 92 %, and it showed 100 % for cases with adhesion or invasion of the bladder. Therefore, CT can an extremely effective method to determine the clinical staging of cancer of the uterine cervix.

  9. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  10. Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model

    International Nuclear Information System (INIS)

    Coppenrath, E.; Meindl, T.; Herzog, P.; Khalil, R.; Mueller-Lisse, U.; Krenn, L.; Reiser, M.; Mueller-Lisse, U.G.

    2006-01-01

    A novel ureter phantom was developed for investigations of image quality and dose in CT urography. The ureter phantom consisted of a water box (14 cm x 32 cm x 42 cm) with five parallel plastic tubes (diameter 2.7 mm) filled with different concentrations of contrast media (1.88-30 mg iodine/ml). CT density of the tubes and noise of the surrounding water were determined using two multidetector scanners (Philips MX8000 with four rows, Siemens Sensation 16 with 16 rows) with varying tube current-time product (15-100 mAs per slice), voltage (90 kV, 100 kV, 120 kV), pitch (0.875-1.75), and slice thickness (1 mm, 2 mm, 3.2 mm). Contrast-to-noise ratio as a parameter of image quality was correlated with dose (CTDI) and was compared with image evaluation by two radiologists. The CT densities of different concentrations of contrast media and contrast-to-noise ratio were significantly higher when low voltages (90 kV versus 120 kV, 100 kV versus 120 kV) were applied. Smaller slice thickness (1 mm versus 2 mm) did not change CT density but decreased contrast-to-noise ratio due to increased noise. Contrast phantom studies showed favourable effects of low tube voltage on image quality in the low dose range. This may facilitate substantial dose reduction in CT urography. (orig.)

  11. A related study of the CT imaging of the chronic low back pain

    International Nuclear Information System (INIS)

    Zhan Zhigang

    2006-01-01

    Objective: To study the clinical application of the CT imaging in patients with chronic low back pain. Methods: CT images were retrospectively analyzed in 164 cases of chronic low back pain. All the cases were diagnosed with CT imaging, or confirmed by operation, or proved in follow-up. Results: Intervertebral disc bulging in different level as a result from the degeneration of the disc was found in 148 cases (90.24%) out of 164. Disc protrusion was presented in 129 cases(78.66%). Bony narrowing of the spinal canal was revealed in 33 cases(20.12%). Degenerative lumbar spinal instability yielded in 14 cases (8.5%). Ossification or calcification of posterior longitudinal ligament was seen in 26 cases (15.85%). Thickening of ligamenta flava was shown in the 22 eases (13.41%). Conclusion: Chronic low back pain is mainly caused by the disorders of the intervertebral disc, which has typical CT findings: narrowed spinal canal or lateral recess. Ossification or calcification of posterior longitudinal ligament also plays a role in low back pain. An accurate interpretation of the CT images is essential for the clinical management. (authors)

  12. Detection of pulmonary fat embolism with dual-energy CT: an experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhou, Chang Sheng; Zhao, Yan E.; Han, Zong Hong; Qi, Li; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Mangold, Stefanie; Ball, B.D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-04-15

    To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. (orig.)

  13. Comparative study of CT scan findings and intellectual function between Parkinson's disease and vascular Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Indo, Toshikatsu

    1986-01-01

    Comparative study of CT scan findings and intellectual function between 64 cases with Parkinson's disease and 25 cases with vascular Parkinsonism was carried out. The rate of abnormality of CT scan findings, either ventricular dilatation or widening of sulci, in vascular Parkinsonism was strikingly high compared with Parkinson's disease. Patients could be divided into three groups according to the degree of overall abnormalities of CT scan findings (group A: markedly abnormal, group B: mildly abnormal, group C: normal). Incidences of group A were 9.4 % in Parkinson's disease and 52 % in vascular Parkinsonism, whereas those of group C were 56 % in the former and 28 % in the latter. All patients of group A were over 65 years of age in Parkinson's disease, but one-third of patients in group A were under 59 years of age in vascular Parkinsonism. Moreover, in vascular Parkinsonism, the level of disability was directly proportional to the abnormality of CT scan findings. The rate of predementia and dementia classified by Hasegawa's intelligence scale was 12.5 % in Parkinson's disease and 48 % in vascular Parkinsonism. No difference was found between the mean values of intelligence scale and background factors in Parkinson's disease. On the other hand, the mean value was significantly low in proportion to the poverty of L-dopa effect in vascular Parkinsonism. From these results, the abnormality of CT scan findings and intellectual impairment were probably related to the cerebral pathological process in vascular Parkinsonism, but these relationship was absent in Parkinson's disease.

  14. Study of CT head scans using different voltages: image quality evaluation

    International Nuclear Information System (INIS)

    Pacheco de Freitas C, I.; Prata M, A.; Alonso, T. C.; Santana, P.

    2016-10-01

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  15. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko; Lampinen, Anniina [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); University of Helsinki, Department of Physics, Helsinki (Finland); Palmu, Kirsi [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); School of Science, Aalto University, Department of Biomedical Engineering and Computational Science, Helsinki (Finland); Reijonen, Vappu; Kortesniemi, Mika [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); Leikola, Junnu [University of Helsinki and Helsinki University Hospital, Department of Plastic Surgery, Helsinki (Finland); Kivisaari, Riku [University of Helsinki and Helsinki University Hospital, Department of Neurosurgery, Helsinki (Finland)

    2015-09-15

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality. (orig.)

  16. Indications for computed tomography (CT-) diagnostics in proximal humeral fractures: a comparative study of plain radiography and computed tomography

    OpenAIRE

    Weise Kuno; Pereira Philippe L; Dietz Klaus; Eingartner Christoph; Schmal Hagen; Südkamp Norbert P; Rolauffs Bernd; Bahrs Christian; Lingenfelter Erich; Helwig Peter

    2009-01-01

    Abstract Background Precise indications for computed tomography (CT) in proximal humeral fractures are not established. The purpose of this study was a comparison of conventional radiographic views with different CT reconstructions with 2 D and 3 D imaging to establish indications for additional CT diagnostics depending on the fractured parts. Methods In a prospective diagnostic study in two level 1 trauma centers, 44 patients with proximal humeral fractures were diagnosed with conventional X...

  17. Anterior mediastinal masses in the Framingham Heart Study: Prevalence and CT image characteristics

    International Nuclear Information System (INIS)

    Araki, Tetsuro; Nishino, Mizuki; Gao, Wei; Dupuis, Josée; Washko, George R.; Hunninghake, Gary M.; Murakami, Takamichi; O’Connor, George T.; Hatabu, Hiroto

    2015-01-01

    To investigate the prevalence and CT image characteristics of anterior mediastinal masses in a population-based cohort and their association with the demographics of the participants. Chest CT scans of 2571 Framingham Heart Study participants (mean age 58.9 years, 51% female) were evaluated by two board-certified radiologists with expertise in thoracic imaging for the presence of anterior mediastinal masses, their shape, contour, location, invasion of adjacent structures, fat content, and calcification. For participants with anterior mediastinal masses, a previous cardiac CT scan was reviewed for interval size change of the masses, when available. The demographics of the participants were studied for any association with the presence of anterior mediastinal masses. Of 2571, 23 participants (0.9%, 95% CI: 0.6–1.3) had anterior mediastinal masses on CT. The most common CT characteristics were oval shape, lobular contour, and midline location, showing soft tissue density (median 32.1 HU). Fat content was detected in a few cases (9%, 2/23). Six out of eight masses with available prior cardiac CT scans demonstrated an interval growth over a median period of 6.5 years. No risk factors for anterior mediastinal masses were detected among participants’ demographics, including age, sex, BMI, and cigarette smoking. The prevalence of anterior mediastinal masses is 0.9% in the Framingham Heart Study. Those masses may increase in size when observed over 5–7 years. Investigation of clinical significance in incidentally found anterior mediastinal masses with a longer period of follow-up would be necessary

  18. A clinical study of acute cerebral infarction with a midline shift on the CT scan

    International Nuclear Information System (INIS)

    Takemae, Toshiki; Mizukami, Masahiro; Kin, Hiroshi; Kawase, Takeshi; Araki, Goro

    1978-01-01

    Twenty-one cases of acute cerebral infarction with a midline shift on the CT scan were studied with respect to the development of the midline shift, the angiographic findings, the clinical pictures and the outcome of these patients. The CT findings of hemorrhagic infarction were also studied. No cases showed a midline shift on a CT scan taken within 6 hours after the onset. A midline shift was, however, noted as early as 9 hours after the onset, and it reached its peak between the 2nd and 7th day of the onset. It gradually disappeared by the end of the third week. Hemorrhagic infarction was diagnosed in 6 patients by either spinal tap or autopsy. The CT findings of these hemorrhagic infarction were divided into two types, solid hemorrhages with an unequivocal high density within the low-density area, and small, scattered hemorrhagic of almost the same density as normal brain tissue within the low-density area. In 19 of 21 patients, an round-edged occlusion and/or embolus were observed on the initial angiograms. The recanalization of the occluded vessels was proved in 10 of 14 patients by subsequent angiographic studies. Twenty of 21 patients showed a sudden development of neurological symptoms, and 15 patients had a history of various kinds of heart disease, such as atrial fibrillation, valvular heart disease and myocardial infarction. The patients had atrial fibrillation on EKG on admission. These angiographic findings and clinical pictures strongly suggest that the infarction with a midline shift on the CT scan may be caused by a cerebral embolism of cardiac origin. Eight patients died of cerebral herniation between the 2nd and 6th day of the onset. Taking these poor outcomes into consideration, surgical as well as medical decompression of the brain would seem to be most important when the CT scan shows a midline shift. (author)

  19. Clinical study of acute cerebral infarction with a midline shift on the CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takemae, T; Mizukami, M; Kin, H; Kawase, T; Araki, G [Mihara Memorial Hospital, Isezaki, Gunma (Japan)

    1978-12-01

    Twenty-one cases of acute cerebral infarction with a midline shift on the CT scan were studied with respect to the development of the midline shift, the angiographic findings, the clinical pictures and the outcome of these patients. The CT findings of hemorrhagic infarction were also studied. No cases showed a midline shift on a CT scan taken within 6 hours after the onset. A midline shift was, however, noted as early as 9 hours after the onset, and it reached its peak between the 2nd and 7th day of the onset. It gradually disappeared by the end of the third week. Hemorrhagic infarction was diagnosed in 6 patients by either spinal tap or autopsy. The CT findings of these hemorrhagic infarction were divided into two types, solid hemorrhages with an unequivocal high density within the low-density area, and small, scattered hemorrhagic of almost the same density as normal brain tissue within the low-density area. In 19 of 21 patients, an round-edged occlusion and/or embolus were observed on the initial angiograms. The recanalization of the occluded vessels was proved in 10 of 14 patients by subsequent angiographic studies. Twenty of 21 patients showed a sudden development of neurological symptoms, and 15 patients had a history of various kinds of heart disease, such as atrial fibrillation, valvular heart disease and myocardial infarction. The patients had atrial fibrillation on EKG on admission. These angiographic findings and clinical pictures strongly suggest that the infarction with a midline shift on the CT scan may be caused by a cerebral embolism of cardiac origin. Eight patients died of cerebral herniation between the 2nd and 6th day of the onset. Taking these poor outcomes into consideration, surgical as well as medical decompression of the brain would seem to be most important when the CT scan shows a midline shift.

  20. Comparative study of myelography with postmyelographic CT in cervical spondylosis and herniated disk

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyoon Soon; Park, Yong Tae; Choi, Woo Suk; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    Eight patients, who had symptoms and signs of cervical spondylosis and/or disk were studied with myelography (using Omnipaque) followed by postmyelographic computed tomography to evaluate the relative efficacy of these two methods in the determination of cervical herniation and spondylosis. Thirty nine levels in 26 patients were confirmed by surgery. Of these, 20 levels proved to have operative evidence of herniated disk. Postmyelographic CT adds useful information to the myelographic findings. Cord and root compression are better evaluated and osteopathy can be differentiated from disk herniation. In osteopathy, myelography was as diagnostic as postmyelographic CT. But, disk herniation was identified in 70% (14/20 levels) with postmyelographic CT and only in 15% (3/20 levels) with myelography.

  1. Comparative study of myelography with postmyelographic CT in cervical spondylosis and herniated disk

    International Nuclear Information System (INIS)

    Jung, Kyoon Soon; Park, Yong Tae; Choi, Woo Suk; Lee, Sun Wha; Lim, Jae Hoon

    1988-01-01

    Eight patients, who had symptoms and signs of cervical spondylosis and/or disk were studied with myelography (using Omnipaque) followed by postmyelographic computed tomography to evaluate the relative efficacy of these two methods in the determination of cervical herniation and spondylosis. Thirty nine levels in 26 patients were confirmed by surgery. Of these, 20 levels proved to have operative evidence of herniated disk. Postmyelographic CT adds useful information to the myelographic findings. Cord and root compression are better evaluated and osteopathy can be differentiated from disk herniation. In osteopathy, myelography was as diagnostic as postmyelographic CT. But, disk herniation was identified in 70% (14/20 levels) with postmyelographic CT and only in 15% (3/20 levels) with myelography.

  2. A follow-up study by CT and MRI in 3 cases of Japanese encephalitis

    International Nuclear Information System (INIS)

    Shoji, H.; Murakami, T.; Murai, I.; Kida, H.; Sato, Y.; Kojima, K.; Abe, T.; Okudera, T.

    1990-01-01

    A follow-up study by CT and MRI in 3 cases of Japanese encephalitis (JE) was performed. Neurologically dementia, forced laughing, tetraplegia and parkinsonism were observed as sequelae. In the CT and MR scans about 3 years after the onset of JE, low-density areas (LDAs) or abnormal signal intensities had remained in the thalamus and basal ganglia. The abnormalities were also found in the brain stem. When the main lesions shown by CT and MRI were compared with those of the acute stage, T2-weighted MRI clearly revealed multiple small areas with high signal intensities, although the ones at the acute stage had showed diffuse abnormal signals. These findings may be useful in helping to identity a long time after the onset. (orig.)

  3. Thoracic CT in the ED: a study of thoracic computed tomography utilisation.

    LENUS (Irish Health Repository)

    Williams, E

    2010-02-01

    The aim of this retrospective study was to investigate the use of thoracic Computed Tomography (CT) in the Emergency Department of a Dublin Academic Teaching Hospital over a six month period. Data was retrieved using the hospital\\'s computerised information system. There were 202 referrals in total for thoracic CT from the Emergency Department during this time period. The most common indication for thoracic CT referral was for the investigation of pulmonary embolism with 127 (63%) referrals. There were 40 (25%) referrals for suspected malignancy and lung disease, whilst 8 (4%) of the referrals were for investigation of thoracic aortic dissection, 8 (4%) for infection, and 6 (3%) were for investigation of thoracic injury. Only 8 (4%) of all referrals were for investigation of injury as a result of chest trauma.

  4. The sensitivity of CT and rCBF-studies for the pathology of strokes

    International Nuclear Information System (INIS)

    Kohlmeyer, K.

    1980-01-01

    A localized pathology of the cerebral circulation or cerebral metabolism and the morphology of the brain tissue can be visualized by the use of new techniques in radiology and nuclear medicine: measurements of rCBF by radioactive diffusible isotopes, of the densitiy of the brain tissue, by CT, and of the cerebral metabolism regionally by positron-emission tomography. Having studied 475 stroke patients par rCBF measurements and 335 by CT we think it useful to compare the value of these two methods in revealing information on the pathology underlying focal disorders of brain functions due to stroke. (orig./VJ) [de

  5. Bone formation rather than inflammation reflects Ankylosing Spondylitis activity on PET-CT: a pilot study

    OpenAIRE

    Bruijnen, Stefan TG; van der Weijden, Mignon AC; Klein, Joannes P; Hoekstra, Otto S; Boellaard, Ronald; van Denderen, J Christiaan; Dijkmans, Ben AC; Voskuyl, Alexandre E; van der Horst-Bruinsma, Irene E; van der Laken, Conny J

    2012-01-01

    Introduction Positron Emission Tomography - Computer Tomography (PET-CT) is an interesting imaging technique to visualize Ankylosing Spondylitis (AS) activity using specific PET tracers. Previous studies have shown that the PET tracers [18F]FDG and [11C](R)PK11195 can target inflammation (synovitis) in rheumatoid arthritis (RA) and may therefore be useful in AS. Another interesting tracer for AS is [18F]Fluoride, which targets bone formation. In a pilot setting, the potential of PET-CT in ima...

  6. The effect of CT scanners in the trauma room – an observational study

    DEFF Research Database (Denmark)

    Wulffeld, S.; Rasmussen, L. S.; Højlund Bech, B.

    2017-01-01

    with a trauma resuscitation table. Subgroup analyses were performed on severely injured and patients with traumatic brain injury. Results: We included 784 patients before and 742 patients after the reconstruction. Case-mix differed between study periods as there was a higher proportion of severe injuries......, traumatic brain injury and penetrating trauma in the after period. We found a minor increase in time to CT in the after period (20 vs. 21 min, P = 0.008). In a multivariate regression analysis adjusted for differences in case-mix and with time to CT as outcome, period was an insignificant explanatory...

  7. Effects of freezing on white perch Morone americana (Gmelin, 1789): Implications for multivariate morphometrics

    Science.gov (United States)

    Kocovsky, Patrick

    2016-01-01

    This study tested the hypothesis that duration of freezing differentially affects whole-body morphometrics of a derived teleost. Whole-body morphometrics are frequently analyzed to test hypotheses of different species, or stocks within a species, of fishes. Specimens used for morphometric analyses are typically fixed or preserved prior to analysis, yet little research has been done on how fixation or preservation methods or duration of preservation of specimens might affect outcomes of multivariate statistical analyses of differences in shape. To determine whether whole-body morphometrics changed as a result of freezing, 23 whole-body morphometrics of age-1 white perch (Morone americana) from western Lake Erie (n = 211) were analyzed immediately after capture, after being held on ice overnight, and after freezing for 100 or 200 days. Discriminant function analysis revealed that all four groups differed significantly from one another (P time to avoid biases related to the length of time they were frozen. Similar experiments should be conducted on other species and also using formalin- and alcohol-preserved specimens.

  8. Morphometric synaptology of a whole neuron profile using a semiautomatic interactive computer system.

    Science.gov (United States)

    Saito, K; Niki, K

    1983-07-01

    We propose a new method of dealing with morphometric synaptology that processes all synapses and boutons around the HRP marked neuron on a large composite electron micrograph, rather than a qualitative or a piecemeal quantitative study of a particular synapse and/or bouton that is not positioned on the surface of the neuron. This approach requires the development of both neuroanatomical procedures, by which a specific whole neuronal profile is identified, and valuable specialized tools, which support the collection and analysis of a great volume of morphometric data from composite electron micrographs, in order to reduce the burden of the morphologist. The present report is also concerned with the total and reliable semi-automatic interactive computer system for gathering and analyzing morphometric data that has been under development in our laboratory. A morphologist performs the pattern recognition portion by using a large-sized tablet digitizer and a menu-sheet command, and the system registers the various morphometric values of many different neurons and performs statistical analysis. Some examples of morphometric measurements and analysis show the usefulness and efficiency of the proposed system and method.

  9. The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

    Science.gov (United States)

    Vorona, G A; Zuccoli, G; Sutcavage, T; Clayton, B L; Ceschin, R C; Panigrahy, A

    2013-01-01

    Iterative reconstruction techniques facilitate CT dose reduction; though to our knowledge, no group has explored using iterative reconstruction with pediatric head CT. Our purpose was to perform a feasibility study to assess the use of ASIR in a small group of pediatric patients undergoing head CT. An Alderson-Rando head phantom was scanned at decreasing 10% mA intervals relative to our standard protocol, and each study was then reconstructed at 10% ASIR intervals. An intracranial region of interest was consistently placed to estimate noise. Our ventriculoperitoneal shunt CT protocol was subsequently modified, and patients were scanned at 20% ASIR with approximately 20% mA reductions. ASIR studies were anonymously compared with older non-ASIR studies from the same patients by 2 attending pediatric neuroradiologists for diagnostic utility, sharpness, noise, and artifacts. The phantom study demonstrated similar noise at 100% mA/0% ASIR (3.9) and 80% mA/20% ASIR (3.7). Twelve pediatric patients were scanned at reduced dose at 20% ASIR. The average CTDI(vol) and DLP values of the 20% ASIR studies were 22.4 mGy and 338.4 mGy-cm, and for the non-ASIR studies, they were 28.8 mGy and 444.5 mGy-cm, representing statistically significant decreases in the CTDI(vol) (22.1%, P = .00007) and DLP (23.9%, P = .0005) values. There were no significant differences between the ASIR studies and non-ASIR studies with respect to diagnostic acceptability, sharpness, noise, or artifacts. Our findings suggest that 20% ASIR can provide approximately 22% dose reduction in pediatric head CT without affecting image quality.

  10. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  11. Can skull form predict the shape of the temporomandibular joint? A study using geometric morphometrics on the skulls of wolves and domestic dogs.

    Science.gov (United States)

    Curth, Stefan; Fischer, Martin S; Kupczik, Kornelius

    2017-11-01

    The temporomandibular joint (TMJ) conducts and restrains masticatory movements between the mammalian cranium and the mandible. Through this functional integration, TMJ morphology in wild mammals is strongly correlated with diet, resulting in a wide range of TMJ variations. However, in artificially selected and closely related domestic dogs, dietary specialisations between breeds can be ruled out as a diversifying factor although they display an enormous variation in TMJ morphology. This raises the question of the origin of this variation. Here we hypothesise that, even in the face of reduced functional demands, TMJ shape in dogs can be predicted by skull form; i.e. that the TMJ is still highly integrated in the dog skull. If true, TMJ variation in the dog would be a plain by-product of the enormous cranial variation in dogs and its genetic causes. We addressed this hypothesis using geometric morphometry on a data set of 214 dog and 60 wolf skulls. We digitized 53 three-dimensional landmarks of the skull and the TMJ on CT-based segmentations and compared (1) the variation between domestic dog and wolf TMJs (via principal component analysis) and (2) the pattern of covariation of skull size, flexion and rostrum length with TMJ shape (via regression of centroid size on shape and partial least squares analyses). We show that the TMJ in domestic dogs is significantly more diverse than in wolves: its shape covaries significantly with skull size, flexion and rostrum proportions in patterns which resemble those observed in primates. Similar patterns in canids, which are carnivorous, and primates, which are mostly frugivorous imply the existence of basic TMJ integration patterns which are independent of dietary adaptations. However, only limited amounts of TMJ variation in dogs can be explained by simple covariation with overall skull geometry. This implies that the final TMJ shape is gained partially independently of the rest of the skull. Copyright © 2017 Elsevier Gmb

  12. Morphometric analysis of the Marmara Sea river basins, Turkey

    Science.gov (United States)

    Elbaşı, Emre; Ozdemir, Hasan

    2014-05-01

    The drainage basin, the fundamental unit of the fluvial landscape, has been focus of research aimed at understanding the geometric characteristics of the master channel and its tributary network. This geometry is referred to as the basin morphometry and is nicely reviewed by Abrahams (1984). A great amount of research has focused on geometric characteristic of drainage basins, including the topology of the stream networks, and quantitative description of drainage texture, pattern, shape, and relief characteristics. Evaluation of morphometric parameters necessitates the analysis of various drainage parameters such as ordering of the various streams, measurement of basin area and perimeter, length of drainage channels, drainage density (Dd), stream frequency (Fs), bifurcation ratio (Rb), texture ratio (T), basin relief (Bh), Ruggedness number (Rn), time of concentration (Tc), hypsometric curve and integral (Hc and Hi) (Horton, 1932, Schumn, 1956, Strahler, 1957; Verstappen 1983; Keller and Pinter, 2002; Ozdemir and Bird, 2009). These morphometric parameters have generally been used to predict flood peaks, to assess sediment yield, and to estimate erosion rates in the basins. River basins of the Marmara Sea, has an area of approximately 40,000 sqkm, are the most important basins in Turkey based on their dense populations, industry and transportation systems. The primary aim of this study is to determine and analyse of morphometric characteristics of the Marmara Sea river basins using 10 m resolution Digital Elevation Model (DEM) and to evaluate of the results. For these purposes, digital 10 m contour maps scaled 1:25000 and geological maps scaled 1:100000 were used as the main data sources in the study. 10 m resolution DEM data were created using the contour maps and then drainage networks and their watersheds were extracted using D8 pour point model. Finally, linear, areal and relief morphometries were applied to the river basins using Geographic Information Systems

  13. Quality control of CT systems by automated monitoring of key performance indicators: a two-year study.

    Science.gov (United States)

    Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette

    2015-07-08

    The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.

  14. Semi-automated landmark-based 3D analysis reveals new morphometric characteristics in the trochlear dysplastic femur.

    Science.gov (United States)

    Van Haver, Annemieke; De Roo, Karel; De Beule, Matthieu; Van Cauter, Sofie; Audenaert, Emmanuel; Claessens, Tom; Verdonk, Peter

    2014-11-01

    The authors hypothesise that the trochlear dysplastic distal femur is not only characterised by morphological changes to the trochlea. The purpose of this study is to describe the morphological characteristics of the trochlear dysplastic femur in and outside the trochlear region with a landmark-based 3D analysis. Arthro-CT scans of 20 trochlear dysplastic and 20 normal knees were used to generate 3D models including the cartilage. To rule out size differences, a set of landmarks were defined on the distal femur to isotropically scale the 3D models to a standard size. A predefined series of landmark-based reference planes were applied on the distal femur. With these landmarks and reference planes, a series of previously described characteristics associated with trochlear dysplasia as well as a series of morphometric characteristics were measured. For the previously described characteristics, the analysis replicated highly significant differences between trochlear dysplastic and normal knees. Furthermore, the analysis showed that, when knee size is taken into account, the cut-off values of the trochlear bump and depth would be 1 mm larger in the largest knees compared to the smallest knees. For the morphometric characteristics, the analysis revealed that the trochlear dysplastic femur is also characterised by a 10% smaller intercondylar notch, 6-8% larger posterior condyles (lateral-medial) in the anteroposterior direction and a 6% larger medial condyle in the proximodistal direction compared to a normal femur. This study shows that knee size is important in the application of absolute metric cut-off values and that the posterior femur also shows a significantly different morphology.

  15. The study of measuring small gap made from different in closed body with industrial CT

    International Nuclear Information System (INIS)

    Yang Wan; Ye Yunchang; Deng Jun; Chen Fa

    2011-01-01

    It studies the measurement of small gap between spherical samples made from different material. It can gain the picture of sample by industrial CT scan. Then it can draw the border of measured sphere and find the coordinate of center and diameter of sphere and get surface integral region of measured gap. And it measure small gap by writing special measuring software. (authors)

  16. CT-guided radiolabelled aerosol studies for assessing pulmonary impairment in children with bronchiectasis

    International Nuclear Information System (INIS)

    Pifferi, M.; Baldini, M.; Caramella, D.; Bartolozzi, C.; Di Mauro, M.; Cangiotti, A.M.

    2000-01-01

    Objective. To determine whether CT-guided mucociliary clearance studies allow differentiation between bronchiectasis associated with primary ciliary dyskinesia (PCD) and those unrelated to congenital or genetically transmitted defects. Materials and methods. Fifteen children aged 4-18 years with a CT diagnosis of bronchiectasis were included in the study. Six had PCD, while in nine cases no congenital disorder was demonstrated. Results. CT showed bronchiectasis in 26 (29 %) of 90 lung regions. Radiolabelled aerosol studies were conducted globally for each lung and on the regions affected by bronchiectasis. Global half-time of activity (t 1/2 ) values of patients with PCD were significantly higher (P 1/2 values. Patients with bronchiectasis unrelated to congenital disorders showed significantly higher regional t 1/2 values in the affected regions with respect to the corresponding global pulmonary t 1/2 (P < 0.06). Conclusions. The combination of morphological CT information with functional data concerning the clearance of radiolabelled aerosol adds to our understanding of pulmonary impairment in children with bronchiectasis. In particular, regional studies allow the recognition of different mucociliary clearance patterns in bronchiectasis associated with PCD and those unrelated to congenital or genetically transmitted defects. (orig.)

  17. Limited-preparation CT colonography in frail elderly patients: a feasibility study.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2010-05-01

    Full colonic preparation can be onerous and may be poorly tolerated in frail elderly patients. The purpose of this study was to prospectively assess the image quality and diagnostic yield of limited-preparation CT colonography (CTC) in elderly patients with suspected colorectal cancer who were deemed medically unfit or unsuitable for colonoscopy.

  18. Study Finds Small Increase in Cancer Risk after Childhood CT Scans

    Science.gov (United States)

    A study published in the June 6, 2012, issue of The Lancet shows that radiation exposure from computed tomography (CT) scans in childhood results in very small but increased risks of leukemia and brain tumors in the first decade after exposure.

  19. Triplane fracture of the distal tibial epiphysis: radiographic and CT studies

    International Nuclear Information System (INIS)

    Cone, R.O. III; Nguyen, V.; Flournoy, J.G.; Guerra, J. Jr.

    1984-01-01

    The authors analyzed six cases of triplane fracture of the ankle and reviewed the literature. A previously underscribed fracture pattern was identified in one patient. CT studies proved to be useful diagnostic tools in the evaluation of triplane fractures when operative reduction was contemplated

  20. Relationship between renal cortex and parenchyma thickness and renal function: study with CT measurement

    International Nuclear Information System (INIS)

    Xu Yufeng; Tang Guangjian; Jiang Xuexiang

    2006-01-01

    Objective: To study the relationship between renal morphology and renal function, and to assess the value of CT as a criterion to grade renal function. Methods: Enhancement CT were performed in 89 patients with no local renal disease whose split renal glomerular filtration rates (GFR) were measured by renal dynamic imaging with 99 Tc m -DTPA. The 178 kidneys were divided into normal renal function, mild and severe renal impairment groups according to renal function. Differences between three groups respect to the mean thickness of renal cortex and parenchyma were assessed by ANOVA. Using Pearson's correlation test, the correlation between the renal cortex, parenchyma thicknesses and renal GFR were examined. The value of CT in predicting renal function was assessed by using ROC analysis. Results: The renal cortex thicknesses of normal renal function, mild and severe renal impairment groups were (5.9±1.1), (4.6± 1.1), and (3.3±1.0) mm respectively, and the renal parenchyma thicknesses were (26.3±4.2), (21.3±4.6), (16.2±4.6) mm. There were significant differences of renal cortex, parenchyma thicknesses between 3 groups (cortex F=54.78, P<0.01; parenehyma F=43.90, P<0.01). The thicknesses of renal cortex (r=0.752, P<0.01), parenchyma (r=0.738, P<0.01) had positive linear correlation with renal function. ROC analysis of the renal cortex thicknesses measured by CT in predicting mild and severe renal impairment showed that the Az was 0.860 and 0.905 respectively, whereas that of parenchyma was 0.868 and 0.884. Conclusion: The thicknesses of renal cortex, parenchyma measured by CT can reflect renal function. CT was a supplementary method to assess renal function. (authors)

  1. CT and pathologic studies in detecting hepatic involvement of malignant lymphoma

    International Nuclear Information System (INIS)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1985-01-01

    In order to determine the value of CT in detecting lymphomatous involvement of the liver, 57 autopsied cases (48 cases of non-Hodgkin lymphoma and 9 of Hodgkin's disease) were analyzed in detail. Additionally, 90 recent cases of abdominal CT with liver study in the initial staging were reviewed and 6 cases in which the liver had been examined within 2 weeks before autopsy were compared for macroscopic and pathologic findings. The following results were obtained. 1) Autopsy findings in 57 cases of malignant lymphoma. (1) Hepatic involvement was demonstrated in 56% of the patients with non-Hodgkin lymphoma and in 67% of those with Hodgkin's disease. (2) Of these patients with hepatic involvement, intrahepatic nodular lesions over 1.0cm in diameter were macroscopically identified in 22% of the cases of non-Hodgkin lymphoma and 33% of those with Hodgkin's disease. (3) Lymphomatous involvements were seen in many organs in the cases of hepatic involvement. 2) CT examinations of 90 cases for the initial staging showed no significant abnormality in the liver or spleen. 3) Of the 6 cases in which the liver was examined by CT within about 2 weeks before autopsy, lymphomatous involvemet was pathologically diagnosed in 5. Of these, only one having multiple nodules larger than the tip of a thumb was correctly diagnosed by CT. 4) Hepatic involvement of lymphoma was thought to be the end stage, and minimal or early disease was detected in the region of Glisson's capsule. The above findings indicate that early hepatic involvement is not likely to be detected by CT at the present time. (author)

  2. Deep learning for staging liver fibrosis on CT: a pilot study.

    Science.gov (United States)

    Yasaka, Koichiro; Akai, Hiroyuki; Kunimatsu, Akira; Abe, Osamu; Kiryu, Shigeru

    2018-05-14

    To investigate whether liver fibrosis can be staged by deep learning techniques based on CT images. This clinical retrospective study, approved by our institutional review board, included 496 CT examinations of 286 patients who underwent dynamic contrast-enhanced CT for evaluations of the liver and for whom histopathological information regarding liver fibrosis stage was available. The 396 portal phase images with age and sex data of patients (F0/F1/F2/F3/F4 = 113/36/56/66/125) were used for training a deep convolutional neural network (DCNN); the data for the other 100 (F0/F1/F2/F3/F4 = 29/9/14/16/32) were utilised for testing the trained network, with the histopathological fibrosis stage used as reference. To improve robustness, additional images for training data were generated by rotating or parallel shifting the images, or adding Gaussian noise. Supervised training was used to minimise the difference between the liver fibrosis stage and the fibrosis score obtained from deep learning based on CT images (F DLCT score) output by the model. Testing data were input into the trained DCNNs to evaluate their performance. The F DLCT scores showed a significant correlation with liver fibrosis stage (Spearman's correlation coefficient = 0.48, p deep learning model based on CT images, with moderate performance. • Liver fibrosis can be staged by a deep learning model based on magnified CT images including the liver surface, with moderate performance. • Scores from a trained deep learning model showed moderate correlation with histopathological liver fibrosis staging. • Further improvement are necessary before utilisation in clinical settings.

  3. Experimental study of CT perfusion in hepatitis, hepatic fibrosis and early stage of cirrhosis

    International Nuclear Information System (INIS)

    Guan Sheng; Zhao Weidong; Zhou Kangrong; Peng Weijun; Mao Jian; Tang Feng; Wang Yong; Cao Guang; Sun Fei

    2005-01-01

    Objective: To investigate the value of CT perfusion in the early diagnosis of hepatic diffuse disease. Methods: Fourteen male Wistar rats of control group and 14 of test group at stages of hepatitis, hepatic fibrosis, hepatic cirrhosis which were induced with diethylnitrosamine (DEN), were studied with CT perfusion respectively. CT perfusion data of different stages were compared and pathologic analysis were performed. Results: Density-time curves of CT perfusion were satisfactory and all perfusion data could be obtained. During the period of hepatitis developing into early stage of hepatic cirrhosis, hepatic artery flow (HAF) trended to increase in test group, mean transmit time (MTT) prolonged obviously, blood flow (BF) and volume (BV) declined. While in control group, HAF declined slightly, MTT, BV and BF increased. Statistic analysis showed the differences of HAF and MTT at different stages between control and test groups were significant (P<0.05 ); the differences of BV and BF between hepatitis and hepatic cirrhosis, hepatic fibrosis and early stage of hepatic cirrhosis in test group were significant (P<0.05), but no significant difference between hepatitis and hepatic fibrosis. The corresponding pathologic changes at stage of hepatitis was swelling of hepatic cells; sinusoids cap illarization and deposition of collagen in the extravascular Disse's spaces were the main changes relating to hepatic blood perfusion at stage of fibrosis and early stage of cirrhosis. Conclusion: The method of CT scan can reflect some changes of hepatic blood perfusion in rats with hepatitis, hepatic fibrosis and early stage of cirrhosis. The data of CT perfusion, especially the changes should be valuable for clinical early diagnosis, treatment and follow-up. (authors)

  4. Morphometrical Analysis and Peak Runoff Estimation for the Sub-Lower Niger River Basin, Nigeria

    Directory of Open Access Journals (Sweden)

    Salami Adebayo Wahab

    2016-03-01

    Full Text Available This study utilized Spatial Information Technology (SIT such as Remote Sensing (RS, a Geographical Information System (GIS, the Global Positioning System (GPS and a high-resolution Digital Elevation Model (DEM for a morphometrical analysis of five sub-basins within the Lower Niger River Basin, Nigeria. Morpho-metrical parameters, such as the total relief, relative relief, relief ratio, ruggedness number, texture ratio, elongation ratio, circularity ratio, form factor ratio, drainage density, stream frequency, sinuosity factor and bifurcation ratio, have been computed and analyzed. The study revealed that the contribution of the morphometric parameters to flooding suggest catchment No. 1 has the least concentration time and the highest runoff depth. Catchment No. 4 has the highest circularity ratio (0.35 as the most hazardous site where floods could reach a great volume over a small area.

  5. Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw [Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Liu, Shu-Hsin [Department of Nuclear Medicine, Buddhist Tzu-Chi General Hospital, 970, Hualien, Taiwan and Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Mok, Greta S. P. [Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, 112, Taipei, Taiwan (China)

    2014-09-15

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

  6. The value of emergency CT studies in spontaneous rupture of hepatocellular carcinoma. Analysis for tumor protrusion and hemorrhagic ascites

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Makiko; Kobayashi, Hisashi; Ichikawa, Taro; Cho, Keiichi; Gemma, Kazuhito; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1997-12-01

    CT characteristics of spontaneous rupture of HCC (n=13) were reviewed retrospectively, and the value of emergency CT studies in this disease was evaluated. Especially, tumor protrusion ratio (TPR) and ascitic CT numbers were measured to for comparison with the data for unruptured HCCs and ordinary, (e.g., non-hemorrhagic) ascites (n=13). As a result, except for diffuse type HCCs, the TPR was significantly higher than for the unruptured HCCs. Nine cases had intraperitoneal HDAs, and the laterality of the HDAs corresponded with that of the ruptured tumors in 8 cases. Also, the ascitic CT numbers apart from the HDA were still higher than the ordinary ascites. Therefore, a high TPR, HDAs adjacent to the tumor, and elevated ascitic CT numbers are important CT manifestations indicating HCC rupture. Diffuse HCCs, however, require careful clinical evaluation. (author)

  7. The value of emergency CT studies in spontaneous rupture of hepatocellular carcinoma. Analysis for tumor protrusion and hemorrhagic ascites

    International Nuclear Information System (INIS)

    Ishihara, Makiko; Kobayashi, Hisashi; Ichikawa, Taro; Cho, Keiichi; Gemma, Kazuhito; Kumazaki, Tatsuo

    1997-01-01

    CT characteristics of spontaneous rupture of HCC (n=13) were reviewed retrospectively, and the value of emergency CT studies in this disease was evaluated. Especially, tumor protrusion ratio (TPR) and ascitic CT numbers were measured to for comparison with the data for unruptured HCCs and ordinary, (e.g., non-hemorrhagic) ascites (n=13). As a result, except for diffuse type HCCs, the TPR was significantly higher than for the unruptured HCCs. Nine cases had intraperitoneal HDAs, and the laterality of the HDAs corresponded with that of the ruptured tumors in 8 cases. Also, the ascitic CT numbers apart from the HDA were still higher than the ordinary ascites. Therefore, a high TPR, HDAs adjacent to the tumor, and elevated ascitic CT numbers are important CT manifestations indicating HCC rupture. Diffuse HCCs, however, require careful clinical evaluation. (author)

  8. 3D automatic exposure control for 64-detector row CT: Radiation dose reduction in chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Ohno, Yoshiharu; Koyama,