WorldWideScience

Sample records for monthly blood test

  1. Blood Tests

    Science.gov (United States)

    ... of your immune system, which fights infections and diseases. Abnormal white blood cell levels may be a sign ... fall outside the normal range for many reasons. Abnormal results might be a sign of a disorder or disease. Other factors—such as diet, menstrual ...

  2. Blood sugar test

    Science.gov (United States)

    ... sugar; Blood sugar level; Fasting blood sugar; Glucose test; Diabetic screening - blood sugar test; Diabetes - blood sugar test ... The test may be done in the following ways: After you have not eaten anything for at least 8 ...

  3. Porphyrins - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003372.htm Porphyrins blood test To use the sharing features on this page, ... blood or the urine . This article discusses the blood test. How the Test is Performed A blood sample ...

  4. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Bystrzycka, Weronika; Łukasik, Jan; Kotuła, Iwona

    2015-08-01

    Eosin-5'-maleimide (EMA) binding test is a flow cytometric test used to detect hereditary spherocytosis (HS). To perform the test sample from patients, 5-6 reference samples of red blood are needed. Our aim was to investigate how the mean corpuscular volume (MCV) of red blood cells influences on the value of fluorescence of bounded EMA dye and how the choice of reference samples affects the test result. EMA test was performed in peripheral blood from 404 individuals, including 31 children suffering from HS. Mean fluorescence channel of EMA-RBCs was measured with Cytomics FC500 flow cytometer. Mean corpuscular volume of RBCs was assessed with LH750 Beckman Coulter. Statistical analysis was performed using Graph Pad Prism. The correlation Spearman coefficient between mean channel of fluorescence of EMA-RBCs and MCV was r = 0.39, p < 0.0001. Interpretation of EMA test depends on MCV of the reference samples. If reference blood samples have lower MCV than the patients MCV, EMA test result might be negative. Due to different MCV values of RBCs in infancy and ca. Three months later, EMA test in neonates might be interpreted falsely negative. Samples from children younger than 3 months old had EMA test result 86.1 ± 11.7 %, whereas same samples that analyzed 4.1 ± 2.1 later had results of 75.4 ± 4.5 %, p < 0.05. Mean fluorescence of EMA-bound RBC depends on RBC's volume. MCV of reference samples affects EMA test results; thus, we recommend selection of reference samples with MCV in range of ±2 fL compared to MCV of patient RBC's.

  5. Catecholamine blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003561.htm Catecholamine blood test To use the sharing features on this page, ... measured with a urine test than with a blood test. How the Test is Performed A blood sample ...

  6. Myoglobin blood test

    Science.gov (United States)

    Serum myoglobin; Heart attack - myoglobin blood test; Myositis - myoglobin blood test; Rhabdomyolysis - myoglobin blood test ... too high, it can damage the kidneys. This test is ordered when your health care provider suspects ...

  7. Home blood sugar testing

    Science.gov (United States)

    Diabetes - home glucose testing; Diabetes - home blood sugar testing ... Usual times to test your blood sugar are before meals and at bedtime. Your provider may ask you to check your blood sugar 2 hours after a meal or ...

  8. Renin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003698.htm Renin blood test To use the sharing features on this page, ... renin test measures the level of renin in blood. How the Test is Performed A blood sample is needed . How ...

  9. Prolactin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003718.htm Prolactin blood test To use the sharing features on this page, ... test measures the amount of prolactin in the blood. How the Test is Performed A blood sample is needed . How ...

  10. Ketones blood test

    Science.gov (United States)

    Acetone bodies; Ketones - serum; Nitroprusside test; Ketone bodies - serum; Ketones - blood; Ketoacidosis - ketones blood test ... fat cells break down in the blood. This test is used to diagnose ketoacidosis . This is a ...

  11. Haptoglobin blood test

    Science.gov (United States)

    The haptoglobin blood test measures the level of haptoglobin in your blood. Haptoglobin is a protein produced by the liver. It attaches to a certain type of hemoglobin in the blood. Hemoglobin is a blood cell that carries oxygen.

  12. Platelet antibodies blood test

    Science.gov (United States)

    This blood test shows if you have antibodies against platelets in your blood. Platelets are a part of the blood ... Chernecky CC, Berger BJ. Platelet antibody - blood. In: Chernecky ... caused by platelet destruction, hypersplenism, or hemodilution. ...

  13. Gastrin blood test

    Science.gov (United States)

    Peptic ulcer - gastrin blood test ... A blood sample is needed . ... in the stomach, gastrin is released into the blood. As the acid ... provider may order this test if you have signs or symptoms of a ...

  14. Phosphorus blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003478.htm Phosphorus blood test To use the sharing features on this page, please enable JavaScript. The phosphorus blood test measures the amount of phosphate in the blood. ...

  15. Calcium blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003477.htm Calcium blood test To use the sharing features on this page, please enable JavaScript. The calcium blood test measures the level of calcium in the blood. ...

  16. Pyruvate kinase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003357.htm Pyruvate kinase blood test To use the sharing features on this page, ... energy when oxygen levels are low. How the Test is Performed A blood sample is needed. In the laboratory, white blood ...

  17. Ammonia blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003506.htm Ammonia blood test To use the sharing features on this page, ... Encephalopathy - ammonia; Cirrhosis - ammonia; Liver failure - ammonia Images Blood test References Chernecky CC, Berger BJ. Ammonia (NH3) - blood ...

  18. Antithrombin III blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003661.htm Antithrombin III blood test To use the sharing features on this page, ... a protein that helps control blood clotting. A blood test can determine the amount of AT III present ...

  19. Fibrinopeptide A blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003373.htm Fibrinopeptide A blood test To use the sharing features on this page, ... measure the level of this substance in your blood. How the Test is Performed A blood sample is needed. How ...

  20. Blood Test: Bilirubin

    Science.gov (United States)

    ... Videos for Educators Search English Español Blood Test: Bilirubin KidsHealth / For Parents / Blood Test: Bilirubin What's in ... liver or kidneys) is working. What Is a Bilirubin Test? A bilirubin test measures how much bilirubin ...

  1. BUN - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003474.htm BUN - blood test To use the sharing features on this page, ... for the Test Many medicines can interfere with blood test results. Your health care provider will tell you ...

  2. Blood Test: Testosterone

    Science.gov (United States)

    ... Test: Estradiol Precocious Puberty Understanding Puberty Endocrine System Male Reproductive System Getting a Blood Test (Video) All About Puberty Blood Test (Video) Male Reproductive System View more About Us Contact Us Partners Editorial ...

  3. Ethylene glycol blood test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003564.htm Ethylene glycol blood test To use the sharing features ... enable JavaScript. This test measures the level of ethylene glycol in the blood. Ethylene glycol is a ...

  4. Antidiuretic hormone blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003702.htm Antidiuretic hormone blood test To use the sharing features on this page, please enable JavaScript. Antidiuretic blood test measures the level of antidiuretic hormone (ADH) in ...

  5. HCG blood test - qualitative

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003509.htm HCG blood test - qualitative To use the sharing features on this page, please enable JavaScript. A qualitative HCG blood test checks if there is a hormone called human ...

  6. ACE blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003567.htm ACE blood test To use the sharing features on this page, ... Alternative Names Serum angiotensin-converting enzyme; SACE Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  7. LDH isoenzyme blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003499.htm LDH isoenzyme blood test To use the sharing features on this page, ... Names LD; LDH; Lactic (lactate) dehydrogenase isoenzymes Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  8. CEA blood test

    Science.gov (United States)

    Carcinoembryonic antigen blood test ... doing so for a short time before the test. ... When the needle is inserted to draw blood, some people feel ... may be some throbbing or a slight bruise. This soon goes away.

  9. Methylmalonic acid blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003565.htm Methylmalonic acid blood test To use the sharing features on this page, please enable JavaScript. The methylmalonic acid blood test measures the amount of methylmalonic acid in the ...

  10. TBG - blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003374.htm TBG - blood test To use the sharing features on this page, please enable JavaScript. The TBG blood test measures the level of a protein that moves ...

  11. Calcitonin blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003699.htm Calcitonin blood test To use the sharing features on this page, please enable JavaScript. The calcitonin blood test measures the level of the hormone calcitonin in ...

  12. Aldolase blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003566.htm Aldolase blood test To use the sharing features on this page, ... risk any time the skin is broken) Images Blood test References Berridge BR, Van Vleet JF, Herman E. ...

  13. Glucagon blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003716.htm Glucagon blood test To use the sharing features on this page, please enable JavaScript. A glucagon blood test measures the amount of a hormone called glucagon ...

  14. Leucine aminopeptidase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003559.htm Leucine aminopeptidase blood test To use the sharing features on this page, ... Alternative Names Serum leucine aminopeptidase; LAP - serum Images Blood test References Chernecky CC, Berger BJ. Leucine aminopeptidase (LAP) - ...

  15. Fish oil-supplementation from 9 to 12 months of age affects infant attention in a free-play test and is related to change in blood pressure

    DEFF Research Database (Denmark)

    Harbild, Helle Liliegren; Harsløf, Laurine Bente Schram; Christensen, J. H.

    2013-01-01

    This intervention examined whether fish-oil-supplementation in late infancy modifies free-play test scores and if this is related to blood pressure (BP) and mean RR interval.......This intervention examined whether fish-oil-supplementation in late infancy modifies free-play test scores and if this is related to blood pressure (BP) and mean RR interval....

  16. Estradiol blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003711.htm Estradiol blood test To use the sharing features on this page, ... of estrogens. How the Test is Performed A blood sample is needed . How to Prepare for the Test Your health care provider may tell you to ...

  17. Sodium blood test

    Science.gov (United States)

    ... medicines that may affect the test. These include: Antibiotics Antidepressants Some high blood pressure medicines Lithium Nonsteroidal anti-inflammatory drugs (NSAIDs) Water pills (diuretics) DO NOT stop ...

  18. Tularemia blood test

    Science.gov (United States)

    Tularemia test; Serology for Francisella tularensis ... This blood test is done when tularemia is suspected. ... Elsevier; 2017:chap 44. Chernecky CC, Berger BJ. Tularemia agglutinins - serum. In: Chernecky CC, Berger BJ, eds. ...

  19. CO2 blood test

    Science.gov (United States)

    Bicarbonate test; HCO3-; Carbon dioxide test; TCO2; Total CO2; CO2 test - serum; Acidosis - CO2; Alkalosis - CO2 ... Many medicines can interfere with blood test results. Your health ... need to stop taking any medicines before you have this test. DO ...

  20. Luteinizing hormone (LH) blood test

    Science.gov (United States)

    ICSH - blood test; Luteinizing hormone - blood test; Interstitial cell stimulating hormone - blood test ... to temporarily stop medicines that may affect the test results. Be sure to tell your provider about ...

  1. ALP - blood test

    Science.gov (United States)

    ... Tissues with higher amounts of ALP include the liver, bile ducts, and bone. A blood test can be done ... and the A.D.A.M. Editorial team. Bile Duct Diseases Read more Bone Diseases Read more Liver Function Tests Read more A.D.A.M., ...

  2. Flushable reagent stool blood test

    Science.gov (United States)

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  3. Blood Urea Nitrogen Test

    Science.gov (United States)

    ... to affect the kidneys, such as diabetes or high blood pressure , then creatinine and BUN tests may be used to monitor ... the diet. High-protein diets may cause abnormally high BUN levels while very low-protein diets can cause an abnormally low BUN. A wide variety ... a health practitioner will look at ...

  4. Blood Test: Lead (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Lead KidsHealth / For Parents / Blood Test: Lead What's ... español Análisis de sangre: plomo What Is a Blood Test? A blood test is when a sample of ...

  5. Blood Pressure Test

    Science.gov (United States)

    ... pressure monitors may have some limitations. Tracking your blood pressure readings It can be helpful in diagnosing or ... more Stage 2 high blood pressure (hypertension) Elevated blood pressure and stages 1 and 2 high blood pressure ( ...

  6. Parathyroid hormone (PTH) blood test

    Science.gov (United States)

    ... PTH) intact molecule; Intact PTH; Hyperparathyroidism - PTH blood test; Hypoparathyroidism - PTH blood test ... drinking for some period of time before the test. Most often, you will not need to fast ...

  7. Cord blood testing

    Science.gov (United States)

    ... Blood culture (if an infection is suspected) Blood gases (including oxygen, carbon dioxide, and pH levels) Blood ... 2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing by ADAM ...

  8. Aspartate aminotransferase (AST) blood test

    Science.gov (United States)

    ... gov/ency/article/003472.htm Aspartate aminotransferase (AST) blood test To use the sharing features on this page, please enable JavaScript. The aspartate aminotransferase (AST) blood test measures the level of the enzyme AST in ...

  9. Alanine transaminase (ALT) blood test

    Science.gov (United States)

    ... gov/ency/article/003473.htm Alanine transaminase (ALT) blood test To use the sharing features on this page, please enable JavaScript. The alanine transaminase (ALT) blood test measures the level of the enzyme ALT in ...

  10. Comparative changes in monthly blood urea nitrogen, total protein ...

    African Journals Online (AJOL)

    The objective of this study was to determine the comparative changes in the monthly blood urea nitrogen (BUN) concentration, total protein (TP) concentration in blood serum and the body condition score of Nguni cows and heifers raised on sweetveld. Twenty-four clinically healthy animals in different parities, namely Parity ...

  11. Announcement: National High Blood Pressure Education Month - May 2016.

    Science.gov (United States)

    2016-05-27

    May is National High Blood Pressure Education Month. High blood pressure (hypertension) is a major contributor to heart disease and stroke, two leading causes of death in the United States.* High blood pressure affects one third of U.S. adults, or approximately 75 million persons, yet approximately 11 million of these persons are not aware they have hypertension, and approximately 18 million are not being treated (unpublished data) (1,2).

  12. Fibrin degradation products blood test

    Science.gov (United States)

    ... behind when clots dissolve in the blood. A blood test can be done to measure these products. ... Certain medicines can change blood test results. Tell your health care provider about all the medicines you take. Your provider will tell you if you need ...

  13. Creatinine blood test

    Science.gov (United States)

    Serum creatinine; Kidney function - creatinine; Renal function - creatinine ... kidney damage or failure, infection, or reduced blood flow Loss of ... medicine overdose. Your provider will tell you more, if needed.

  14. Vitamin A blood test

    Science.gov (United States)

    ... A higher than normal value means you have excess vitamin A in your blood (toxic levels). This may ... Saunders; 2013:1175-1177. Ross AC, Tan L. Vitamin A deficiencies and excess. In: Kliegman RM, Stanton BF, St. Geme JW, ...

  15. Blood Culture Test

    Science.gov (United States)

    ... Blood Cultures. Medscape from American Journal of Clinical Pathology [On-line information]. Available online at http://www. ... August 2013. Fisher, M. et. al. (Updated 2013 March 20). Sepsis. ARUP Consult [On-line information]. Available ...

  16. Anthrax blood test

    Science.gov (United States)

    Anthrax serology test; Antibody test for anthrax; Serologic test for B. anthracis ... This test may be performed when the health care provider suspects you have anthrax infection. The bacteria that cause ...

  17. Tips on Blood Testing

    Science.gov (United States)

    ... Test Pain, Discomfort and Anxiety Tips to Help Children through Their Medical Tests Tips to Help the Elderly through Their Medical Tests Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About ...

  18. Basic Blood Tests (For Parents)

    Science.gov (United States)

    ... Other medical conditions and some medicines also can cause high blood glucose. Reviewed by: Rupal Christine Gupta, ... (CMP) Urine Test: Creatinine Urine Test: Microalbumin-to-Creatinine Ratio Getting a ...

  19. Potassium Blood Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Potassium, Serum; 426–27 p. Lab ...

  20. Chloride test - blood

    Science.gov (United States)

    Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...

  1. Antibody Blood Tests

    Science.gov (United States)

    ... out for sure? If antibody tests and/or symptoms suggest celiac disease, the physician needs to establish the diagnosis by ... who is still experiencing symptoms, to establish the diagnosis or to rule out celiac disease as a part of establishing another diagnosis. Find ...

  2. Evaluation of blood zinc, calcium and blood lead levels among children aged 1-36 months.

    Science.gov (United States)

    Ji, Xiaojun; He, Hong; Ren, Lisheng; Liu, Ji; Han, Chunhua

    2014-09-01

    Early childhood lead exposure is associated with numerous adverse health effects. Biomonitoring among susceptible populations, such as children, has not been previously conducted. The aim of the study is to evaluate the blood lead (Pb) and total blood calcium (Ca) levels; blood zinc (Zn) levels. A cross-sectional study was designed to collect healthy children age 1- 36 months (Mean ± SD: 1.5 ± 0.6 age, 60% boys) in the study from January 2010 to September 2011. The overall mean blood Pb levels were 42.18 ± 12.13 μg/L, the overall mean blood Zn and total blood Ca concentrations were 62.18 ± 12.33 μmol/L and 1.78 ± 0.13 mmol/L, respectively. The prevalence of elevated blood Pb levels in all children was 1.3%. A significant difference was found between female and male subjects for the blood Pb and Zn. After controlling for gender and age, there was a weak positive correlation between total blood Ca and Zn level. The blood Pb levels had a significant negative correlation with total blood Ca level after adjusting for age and gender, and these findings suggest that Pb had effect on positive blood Zn and total blood Ca levels; parents should pay more attention to the nutrition of girls. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  3. Follicle-stimulating hormone (FSH) blood test

    Science.gov (United States)

    ... ency/article/003710.htm Follicle-stimulating hormone (FSH) blood test To use the sharing features on this page, please enable JavaScript. The follicle stimulating hormone (FSH) blood test measures the level of FSH in blood. FSH ...

  4. Bilirubin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/bilirubinbloodtest.html Bilirubin Blood Test To use the sharing features on this page, please enable JavaScript. What is a Bilirubin Blood Test? A bilirubin blood test measures the ...

  5. Anion Gap Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... https://medlineplus.gov/labtests/aniongapbloodtest.html Anion Gap Blood Test To use the sharing features on this page, please enable JavaScript. What is an Anion Gap Blood Test? An anion gap blood test is a way ...

  6. Chloride Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the ...

  7. Heavy Metal Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/heavymetalbloodtest.html Heavy Metal Blood Test To use the sharing features ... this page, please enable JavaScript. What is a Heavy Metal Blood Test? A heavy metal blood test ...

  8. Blood Test: Comprehensive Metabolic Panel (CMP)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Comprehensive Metabolic Panel (CMP) KidsHealth / For Parents / Blood ... de sangre: panel metabólico ampliado What Is a Blood Test? A blood test is when a sample of ...

  9. Lipoprotein (a) Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/lipoproteinabloodtest.html Lipoprotein (a) Blood Test To use the sharing features ... this page, please enable JavaScript. What is a Lipoprotein (a) Blood Test? A lipoprotein (a) test measures ...

  10. Parathyroid hormone-related protein blood test

    Science.gov (United States)

    ... ency/article/003691.htm Parathyroid hormone-related protein blood test To use the sharing features on this page, ... measures the level of a hormone in the blood, called parathyroid hormone-related protein. How the Test is Performed A blood sample is needed . How ...

  11. Allergy Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/allergybloodtest.html Allergy Blood Test To use the sharing features on this page, please enable JavaScript. What is an Allergy Blood Test? Allergies are a common and chronic ...

  12. National High Blood Pressure 12-Month Kit. May 1988.

    Science.gov (United States)

    National Heart and Lung Inst. (DHHS/NIH), Bethesda, MD. National High Blood Pressure Education Program.

    Part I of this kit provides information for program planners and health professionals on ways to overcome barriers to health care among the medically underserved, promote high blood pressure control through the media and other community channels, and improve adherence to treatment among hypertensive patients. It lists additional resources for…

  13. Effects of two months training on blood lactate levels in adolescent swimmers

    Directory of Open Access Journals (Sweden)

    T Atan

    2010-06-01

    Full Text Available The aim of this study is to examine the effects of two months swimming training on aerobic and anaerobic capacities with blood lactate. A total of 17 adolescent male swimmers (15.17±0.81 years were included in the study. The first measurement was conducted 1.5 months after the beginning of the season and this was followed by a second measurement conducted two months after the first measurement. A test protocol of 8x100 m crawl style was applied in the measurements and the subjects swam from slow to fast at five different swimming workloads. Between each training run, blood samples were provided from the earlobes of the subjects in order to measure the amount of blood lactate. Heart rate was measured after five swims. Furthermore, swimming styles and duration were recorded in order to calculate the swimming speed of each subject at each swimming workload. The comparison of blood lactate and speed values of all subjects before and after the training season revealed that lactate acid values had not changed significantly (p>0.05 at the lowest swimming workload (75% and that the speed had significantly increased (p<0.01. As for the rest of the swimming workloads, both lactate acid and speed increased significantly (p<0.05 and p<0.01. Our two month training programme dwelt heavily upon anaerobic training and accordingly aerobic capacity decreased and anaerobic capacity increased at higher speeds. On the other hand, in our study, we found out that anaerobic capacity had not increased only at the 75% workload and that it had decreased at the rest of the workloads.

  14. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  15. Blood-alcohol proficiency test program

    Science.gov (United States)

    1975-01-01

    A preliminary survey has been performed to ascertain the validity of the blood alcohol analysis performed by a number of laboratories on a voluntary basis. Values of accuracy and precision of the tests are presented. /Abstract from report summary pag...

  16. Beta-carotene blood test

    Science.gov (United States)

    The normal range is 50 to 300 mcg/dL or 0.93 to 5.59 micromol/L. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider about ...

  17. Influence of breastfeeding in the first months of life on blood pressure levels of preschool children

    Directory of Open Access Journals (Sweden)

    Luciana Neri Nobre

    2016-11-01

    Conclusion: The results of this study indicate that preschoolers breastfed for a period of less than six months were more likely to have high blood pressure when compared to those breastfed for a longer period, suggesting a protective effect of breastfeeding against high blood pressure in this population.

  18. Blood histamine release: A new allergy blood test

    International Nuclear Information System (INIS)

    Faraj, B.A.; Gottlieb, G.R.; Camp, V.M.; Lollies, P.

    1985-01-01

    Allergen-mediated histamine release from human leukocytes represents an important model for in vitro studies of allergic reactions. The purpose of this study was to determine whether the measurement of histamine released in allergic patients (pts) by radioenzymatic assay following mixing of their blood with common allergens represents a reliable index for diagnosis of atopic allergy. Three categories of allergies were used: (1) housedust and mite; (2) cat and dog dander; (3) trees and grasses and ragweed mixture. The presence of allergy was established by intradermal skin testing in the study group of 82 pts. Significant atopy was defined as ≥ 3+ (overall range 0-4 +, negative to maximum) on skin testing. The test was carried out in tubes with 0.5 ml heparinized blood, 0.5 ml tris albumin buffer, and one of the allergens (60-100 PNU/ml). In 20 controls without allergy, there always was ≤ 4% histamine release (normal response). A significant allergen-mediated histamine release, ranging from 12 to 30% of the total blood histamine content, was observed in 96% of the pts with skin test sensitivity of ≥ 3+. There was good agreement between skin testing and histamine release in terms of the allergen causing the response. Thus, measurement of histamine release in blood in response to allergen challenge represents a clinically useful in vitro test for the diagnosis of atopic allergy. Because data can be obtained from a single sample and are highly quantitative, this new method should have application to the longitudinal study of allergic pts and to the assessment of interventions

  19. Attitudes of Swiss mothers toward unrelated umbilical cord blood banking 6 months after donation.

    Science.gov (United States)

    Danzer, Enrico; Holzgreve, Wolfgang; Troeger, Carolyn; Kostka, Ulrike; Steimann, Sabine; Bitzer, Johanes; Gratwohl, Alois; Tichelli, André; Seelmann, Kurt; Surbek, Daniel V

    2003-05-01

    During the past decade, the use of umbilical cord blood (CB) as a source of transplantable hematopoietic stem cells has been increasing. Little is known about the psychosocial consequences that later affect parents after unrelated CB donation. The objective of this study was to evaluate the attitudes of mothers toward unrelated donation of umbilical CB for transplantation 6 months after giving birth. A prospective study was performed with a standardized, anonymous questionnaire distributed to 131 women 6 months after CB donation. The questionnaire included topics concerning views about the ethical accuracy of having donated CB, emotional responses after donation, concerns about genetic testing and research with CB samples, attitude toward anonymity between her child and possible unrelated CB recipient, and willingness to repeatedly donate umbilical CB in a next pregnancy. The vast majority (96.1%) stated that they would donate umbilical CB again, and all respondents were certain that their decision to have donated umbilical CB was ethical. With regard to the potential risks of genetic testing and "experimentation" of umbilical CB, a significant correlation (p = 0.01) was found between negative attitudes and the decision not to donate umbilical CB again. Additionally, it was observed that women who had a negative experience concerning the donation of CB would not donate again (p = 0.004). This study shows a high degree of satisfaction of unrelated umbilical CB donation for banking in women 6 months after delivery. Despite a well-performed and detailed informed consent procedure, one of the ongoing issues for the donators in CB banking involves the concern regarding of improper use of the cells, such as genetic testing or experimentation. Accurate and detailed counseling of pregnant women and their partners therefore maximizes the likelihood that they will donate CB for unrelated banking. These data provide a basis for the improvement of donor selection procedures

  20. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  1. Cement/bentonite interaction. Results from 16 month laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, O. [Clay Technology AB, Lund (Sweden)

    1997-12-01

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites 5 refs, 48 figs, 11 tabs

  2. Effect of prenatal exposure to different salt concentration on the third month's weight and blood pressure in wistar rat

    International Nuclear Information System (INIS)

    Fereidoun, H.

    2009-01-01

    In utero alterations in fluid and electrolyte endocrine systems may result in permanent effects on offspring. A low sodium intake during prenatal life jeopardizes growth in young rats, prenatal high-salt diet in Sprague-Dawley rats caused an increase in MAP at postnatal day 30. The objective of this study was to determine the effect of prenatal exposure to different salt concentrations on the third month's weight and blood pressure in Wistar rat. This study was performed at the Department of Physiology, Isfahan University of Medical Science, Isfahan, Iran, over a period from 1998 to 2003. Six groups of rat, 1 male and 5 female in each group were exposed to 0.5, 1, 1.4, 1.6, 1.8 and 2 percent of salt concentrations during pre-pregnancy, pregnancy and lactation period, another test group consumed distilled water and control group used Isfahan tap water, other living conditions for all groups were similar. Exposure to different salt concentrations on the third month's weight and blood pressure was evaluated. Prenatal exposure to 0.5 and 1% salt concentrations gives birth to more alive and healthy infants, and third month's weight increased significantly, but blood pressure was not influenced significantly. Salt concentrations higher than 1% increased the maternal and infant mortality rate and blood pressure significantly, but some concentrations decreased third month's weight significantly. Level of dietary salt during intrauterine development can influence on the number of alive and healthy infants, birth weight, third month' weight and blood pressure significantly. There is no need to introduce a salt restricted diet in prenatal care, a balanced diet in sodium during pregnancy is recommended, high salt diet creates harmful effect. (author)

  3. Prealbumin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... enough nutrition if you are in the hospital. Nutrition plays an important role in recovery and healing. Help diagnose certain infections and chronic diseases Why do I need a prealbumin blood test? Your health care provider ... test to keep track of your nutrition if you are in the hospital. You may ...

  4. 21 CFR 640.23 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from...

  5. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  6. BUN (Blood Urea Nitrogen): MedlinePlus Lab Test Information

    Science.gov (United States)

    ... https://medlineplus.gov/labtests/bunbloodureanitrogen.html BUN (Blood Urea Nitrogen) To use the sharing features on this ... please enable JavaScript. What is a BUN (Blood Urea Nitrogen) Test? A BUN, or blood urea nitrogen ...

  7. Value of routine blood tests for prediction of mortality risk in hip fracture patients

    DEFF Research Database (Denmark)

    Mosfeldt, Mathias; Pedersen, Ole Birger Vesterager; Riis, Troels

    2012-01-01

    There is a 5- to 8-fold increased risk of mortality during the first 3 months after a hip fracture. Several risk factors are known. We studied the predictive value (for mortality) of routine blood tests taken on admission.......There is a 5- to 8-fold increased risk of mortality during the first 3 months after a hip fracture. Several risk factors are known. We studied the predictive value (for mortality) of routine blood tests taken on admission....

  8. 21 CFR 640.53 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.53 Section 640.53 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.53 Testing the blood. (a) Blood... prescribed in § 610.40 of this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a...

  9. Blood Count Tests: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish WBC count (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Blood Count Tests ... WBC count Show More Show Less Related Health Topics Bleeding Disorders Blood Laboratory Tests National Institutes of ...

  10. Nanoscale Test Strips for Multiplexed Blood Analysis

    Science.gov (United States)

    Chan, Eugene

    2015-01-01

    A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.

  11. Blood Sugar Testing: Why, When and How

    Science.gov (United States)

    ... exercise affect blood sugar levels Understand how other factors, such as illness or stress, affect blood sugar levels Monitor the effect of ... appropriate device for you. Your doctor or diabetes educator can also help you ... how the process works: Wash and dry your hands well. Insert a ...

  12. Testing for seasonal unit roots in monthly panels of time series

    NARCIS (Netherlands)

    R.M. Kunst (Robert); Ph.H.B.F. Franses (Philip Hans)

    2009-01-01

    textabstractWe consider the problem of testing for seasonal unit roots in monthly panel data. To this aim, we generalize the quarterly CHEGY test to the monthly case. This parametric test is contrasted with a new nonparametric test, which is the panel counterpart to the univariate RURS test that

  13. Analysis and optimization of blood-testing procedures.

    NARCIS (Netherlands)

    Bar-Lev, S.K.; Boxma, O.J.; Perry, D.; Vastazos, L.P.

    2017-01-01

    This paper is devoted to the performance analysis and optimization of blood testing procedures. We present a queueing model of two queues in series, representing the two stages of a blood-testing procedure. Service (testing) in stage 1 is performed in batches, whereas it is done individually in

  14. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    lifting and supporting weights) and have an important influence on blood pressure, it is essential to evaluate blood pressure response to iso- metric effort. This test can reveal high blood pressure that might otherwise not be detected. Only a few ...

  15. 21 CFR 640.5 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... be negative to a serological test for syphilis. (b) Determination of blood group. Each container of... sample. The label shall indicate the extent of typing and the results of all tests performed. If the test... test is negative, the results shall be confirmed by further testing which shall include tests for the...

  16. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood gases (PCO2, PO2) and blood pH test system... Test Systems § 862.1120 Blood gases (PCO2, PO2) and blood pH test system. (a) Identification. A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum...

  17. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  18. Gamma-glutamyl transpeptidase (GGT) blood test

    Science.gov (United States)

    ... test is used to detect diseases of the liver or bile ducts. It is also done with other tests (such ... and bilirubin tests) to tell the difference between liver or bile duct disorders and bone disease. It may also be ...

  19. The appropriateness of preoperative blood testing: A retrospective ...

    African Journals Online (AJOL)

    Background. Inappropriate preoperative blood testing can negatively contribute to healthcare costs. Objective. To determine the extent and cost implications of inappropriate preoperative blood testing in adult patients booked for orthopaedic, general or trauma surgical procedures at a regional hospital in KwaZulu-Natal ...

  20. 21 CFR 864.6550 - Occult blood test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occult blood test. 864.6550 Section 864.6550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a...

  1. [Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].

    Science.gov (United States)

    Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés

    2018-03-15

    Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.

  2. Automated nucleic acid amplification testing in blood banks: An additional layer of blood safety

    Directory of Open Access Journals (Sweden)

    Pragati Chigurupati

    2015-01-01

    Full Text Available Context: A total of 30 million blood components are transfused each year in India. Blood safety thus becomes a top priority, especially with a population of around 1.23 billion and a high prevalence rate of human immunodeficiency virus (HIV, hepatitis B virus (HBV and hepatitis C virus (HCV in general population. Nucleic acid amplification testing (NAT in blood donor screening has been implemented in many developed countries to reduce the risk of transfusion-transmitted viral infections (TTIs. NAT takes care of the dynamics of window period of viruses and offers the safest blood pack for donation. Aims: The aim of this study is to show the value of NAT in blood screening. Settings and Design: Dhanavantari Blood Bank, Rajahmundry, Andhra Pradesh, India. Subjects and Methods: Over a period of 1 year from January 2012 to December 2012, a total number of 15,000 blood donor samples were subjected to tests for HIV, HBV, and HCV by enzyme-linked immunosorbent assay (ELISA method and 8000 ELISA nonreactive samples were subjected for NAT using multiplex polymerase chain reaction technology. Results: Of the 15,000 donors tested, 525 were seroreactive. In 8000 ELISA negative blood samples subjected to NAT, 4 donor samples were reactive for HBV. The NAT yield was 1 in 2000. Conclusions: NAT could detect HIV, HBV, and HCV cases in blood donor samples those were undetected by serological tests. NAT could interdict 2500 infectious donations among our approximate 5 million annual blood donations.

  3. Blood Test: Basic Metabolic Panel (BMP)

    Science.gov (United States)

    ... this topic for: Parents Kids Teens Definition: Hypoglycemia Diabetes Center Hypoglycemia Calcium Urine Test: Microalbumin-to-Creatinine Ratio When Your Child Has a Chronic Kidney Disease Kidneys and Urinary ...

  4. Correlation of Blood Lead Level in Mothers and Exclusively Breastfed Infants: A Study on Infants Aged Less Than Six Months

    Directory of Open Access Journals (Sweden)

    Ahmadshah Farhat

    2013-12-01

    How to cite this article: Farhat A, Mohammadzadeh A, Balali-Mood M, Aghajanpoor-Pasha M, Ravanshad Y. Correlation of Blood Lead Level in Mothers and Exclusively Breastfed Infants: A Study on Infants Aged Less Than Six Months. Asia Pac J Med Toxicol 2013;2:150-2.

  5. Using standard serology blood tests to diagnose latent syphilis

    Directory of Open Access Journals (Sweden)

    G. L. Katunin

    2016-01-01

    Full Text Available Goal. To conduct a comparative assessment of the results of regulated serological tests obtained as a result of blood tests in patients suffering from latent syphilis. Materials and methods. The authors examined 187 patient medical records with newly diagnosed latent syphilis in FGBU GNTsDK (State Research Center for Dermatology, Venereology and Cosmetology, Health Ministry of the Russian Federation, in 2006-2015. The results of patient blood tests were analyzed with the use of non-treponemal (microprecipitation test/RPR and treponemal (passive hemagglutination test, immune-enzyme assay (IgA, IgM, IgG, IFabs, immunofluorescence test and Treponema pallidum immobilization test serology tests. Results. According to the results of blood tests of latent syphilis patients, the largest number of positive results was obtained as a result of treponemal serology tests such as immune-enzyme assay (100%, passive hemagglutination test (100% and IFabs (100%. The greatest number of negative results was observed in non-treponemal (microprecipitation test/RPR serology tests: in 136 (72.7% patients; evidently positive results (4+ test results were obtained in 8 (4.3% patients only. According to the results of a comparative analysis of blood tests in patients suffering from latent syphilis obtained with the use of treponemal serology tests, the greatest number of evidently positive results (4+ was noted for the passive hemagglutination test (67.9%. Negative treponemal test results were obtained with the use of the immunofluorescence test and Treponema pallidum immobilization test (21.9% and 11.8% of cases, respectively. Moreover, weakly positive results prevailed for the immunofluorescence test: in 65 (34.7% patients. Conclusion. These data confirm that the following treponemal tests belong to the most reliable ones for revealing patients suffering from latent syphilis: immune-enzyme assay, passive hemagglutination test and IFabs.

  6. Ferritin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Ferritin, Serum; 296 p. Lab Tests ...

  7. Blood: Tests Used to Assess the Physiological and Immunological Properties of Blood

    Science.gov (United States)

    Quinn, J. G.; Tansey, E. A.; Johnson, C. D.; Roe, S. M.; Montgomery, L. E. A.

    2016-01-01

    The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin…

  8. Clinical evaluation of a 51Cr-labeled red blood cell survival test for in vivo blood compatibility testing

    International Nuclear Information System (INIS)

    Pineda, A.A.; Dharkar, D.D.; Wahner, H.W.

    1984-01-01

    Modified red blood cell survival studies with use of 51Cr were performed in three groups of subjects. Group 1 consisted of normal subjects who were given labeled autologous blood, group 2 were subjects in need of blood transfusions and given labeled ABO and Rh crossmatch-compatible blood, and group 3 were patients in need of blood transfusion but in whom problems arose in finding compatible blood. The results of the studies suggest that for patients with blood compatibility problems, normal red blood cell survival values at 1 hour do not exclude the possibility of severe hemolysis 24 hours later. Thus, if a 1-hour test result is normal, the procedure should be extended routinely to 24 hours. Moreover, the test can be used to evaluate the clinical importance of antibodies. We showed that anti-Yka and anti-Lan were clinically significant, but high-titer, low-avidity antibodies, anti-Kna, anti-I, and anti-HI were clinically insignificant in the cases studied. This finding emphasizes the importance of an in vivo test for the final compatibility evaluation in complicated blood replacement problems

  9. Blood Test: Hemoglobin A1C

    Science.gov (United States)

    ... Why Are Hemoglobin A1c Tests Done? When a child has diabetes, hemoglobin A1c levels are followed to see how well medicines are working. If a child with diabetes has a high hemoglobin A1c level, it may ...

  10. Business travel in Asia: blood tests required?

    Science.gov (United States)

    Karel, S

    1988-03-01

    Travellers to Asian countries face growing hostility as potential carriers of acquired immunodeficiency syndrome (AIDS). Visitors who plan to stay in China, India, the Philippines, or South Korea for more than 1 year must prove that they are AIDS-free. In addition, all foreign students who enter China and India must carry documents indicating that they tested negative for the AIDS virus. The upcoming Olympics poses a special health problem for South Korea, which has not so far required AIDS testing for short-term visitors. A World Health Organization consultation on AIDS infection and international travel has raised questions about the feasibility of an AIDS screening program. The estimated direct cost per traveller for AIDS testing would be US$10-20. Even if all foreign travellers were to be screened, 2 problems could still allow AIDS to enter these countries: black marketing of false health certificates and failing to test foreign nationals who have been abroad. Moreover, a restrictive screening policy for international travellers could result in a decline in tourism and international commerce. Business people who intend to travel to Asia for extended periods of time are advised to check with embassies before their departure to find out what AIDS-related clearances may be required.

  11. The Monthly Variations in the Blood Glucose Level of Capoeta capoeta capoeta (G.ldenstaedt, 1772) Living in Aras River

    OpenAIRE

    AYDIN, Seyit

    2000-01-01

    In this study, the monthly variation in the blood glucose level of Capoeta capoeta capoeta caught from Aras between August 1995 and June 1996 was determined. The average blood glucose level was determined to be 112.04±5.19 mg/dl in males and 106.32±9.68 mg/dl in females and 110.06±4.19 mg/dl in the population. The blood glucose level was highest (141.07±13.67 mg/dl) in April, and lowest (69.14±9.75 mg/dl) in September. It was deter- mined that the level of blood glucose was related to tem...

  12. A Blood Test for Alzheimer's Disease: Progress, Challenges, and Recommendations.

    Science.gov (United States)

    Kiddle, Steven J; Voyle, Nicola; Dobson, Richard J B

    2018-03-29

    Ever since the discovery of APOEɛ4 around 25 years ago, researchers have been excited about the potential of a blood test for Alzheimer's disease (AD). Since then researchers have looked for genetic, protein, metabolite, and/or gene expression markers of AD and related phenotypes. However, no blood test for AD is yet being used in the clinical setting. We first review the trends and challenges in AD blood biomarker research, before giving our personal recommendations to help researchers overcome these challenges. While some degree of consistency and replication has been seen across independent studies, several high-profile studies have seemingly failed to replicate. Partly due to academic incentives, there is a reluctance in the field to report predictive ability, to publish negative findings, and to independently replicate the work of others. If this can be addressed, then we will know sooner whether a blood test for AD or related phenotypes with clinical utility can be developed.

  13. Testing of Some Canine Blood Types in Transfusion Compatibility Assessment

    Directory of Open Access Journals (Sweden)

    L Ognean

    2014-01-01

    Full Text Available Blood types were determined using SHIGETA (n=136 and DEA1.1 (n=25 kits, in two groups of dogs, consisting of patients that underwent blood transfusions and healthy donors. The tests were conducted in accordance with the procedures established by the manufacturers, using specific monoclonal antibodies kits, heparinized blood for the tube agglutination (TUBE and slide (SLIDE methods, and EDTA treated blood for the CARD and chromatographic (CHROM methods. The clear expression of tube agglutination reaction in the SHIGETA kit provided a good detection of antigens. Positive reactions with anti-DEA1.1 were clear and evident with the CHROM test. SHIGETA tests revealed a predominance 1.1B (47.05% of blood type, common in Rotweilers (81.81% and Romanian Shepherds (73.68% and group 1(-B (24.26%, frequently found in German Shepherds (54.16%, these also representing an important source of compatible blood. DEA1.1 type test, revealed a high frequency of positive dogs (75%, associated with lower number of potential donors. Extrapolation of SHIGETA groups into the DEA system, confirmed the 1(-B positive dogs as DEA 1.1 negative, and their prevalence in German Shepherds also confirmed their known tendency to be “ideal donors”. The CHROME test showed a good efficiency in auto agglutination control and detecting DEA1.1 positive dogs, including patients with severe forms of anemia.

  14. ALT Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Alanine Aminotransferase (ALT); p. 31. Lab ...

  15. Calcium Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  16. Blood Glucose Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Glucose Monitoring; 317 p. National Cancer ...

  17. MPV Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Platelet Count; p. 419. Important Physician ...

  18. Albumin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Albumin; 32 p. Johns Hopkins Medicine [ ...

  19. Guidelines on the management of abnormal liver blood tests

    Science.gov (United States)

    Cramb, Rob; Davison, Suzanne M; Dillon, John F; Foulerton, Mark; Godfrey, Edmund M; Hall, Richard; Harrower, Ulrike; Hudson, Mark; Langford, Andrew; Mackie, Anne; Mitchell-Thain, Robert; Sennett, Karen; Sheron, Nicholas C; Verne, Julia; Walmsley, Martine; Yeoman, Andrew

    2018-01-01

    These updated guidelines on the management of abnormal liver blood tests have been commissioned by the Clinical Services and Standards Committee (CSSC) of the British Society of Gastroenterology (BSG) under the auspices of the liver section of the BSG. The original guidelines, which this document supersedes, were written in 2000 and have undergone extensive revision by members of the Guidelines Development Group (GDG). The GDG comprises representatives from patient/carer groups (British Liver Trust, Liver4life, PBC Foundation and PSC Support), elected members of the BSG liver section (including representatives from Scotland and Wales), British Association for the Study of the Liver (BASL), Specialist Advisory Committee in Clinical Biochemistry/Royal College of Pathology and Association for Clinical Biochemistry, British Society of Paediatric Gastroenterology, Hepatology and Nutrition (BSPGHAN), Public Health England (implementation and screening), Royal College of General Practice, British Society of Gastrointestinal and Abdominal Radiologists (BSGAR) and Society of Acute Medicine. The quality of evidence and grading of recommendations was appraised using the AGREE II tool. These guidelines deal specifically with the management of abnormal liver blood tests in children and adults in both primary and secondary care under the following subheadings: (1) What constitutes an abnormal liver blood test? (2) What constitutes a standard liver blood test panel? (3) When should liver blood tests be checked? (4) Does the extent and duration of abnormal liver blood tests determine subsequent investigation? (5) Response to abnormal liver blood tests. They are not designed to deal with the management of the underlying liver disease. PMID:29122851

  20. A randomized 9-month study of blood pressure and body fat responses to aerobic training versus combined aerobic and resistance training in older men.

    Science.gov (United States)

    Sousa, Nelson; Mendes, Romeu; Abrantes, Catarina; Sampaio, Jaime; Oliveira, José

    2013-08-01

    This randomized study evaluated the impact of different exercise training modalities on blood pressure and body fat responses in apparently healthy older men. Forty-eight elderly men (aged 65-75 years) were randomly assigned to an aerobic training group (ATG, n=15), a combined aerobic and resistance training group (CTG, n=16), or a control group (n=17). Both exercise training programs were moderate-to-vigorous intensity, three days/week for 9-months. Strength, aerobic endurance, body fat and blood pressure were measured on five different occasions. The data were analyzed using a mixed-model ANOVA, and the independence between systolic blood pressure (SBP), diastolic blood pressure (DBP) and group was tested. A significant main effect of group (pendurance, with higher performance observed in the CTG. A significant main effect of group (ptraining programs reduce resting blood pressure. However, only the combined exercise training was effective at reducing body fat percentage; consequently, there were larger changes in blood pressure, which result in a significant reduction in hypertensive subjects. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Retention of children under 18 months testing HIV positive in care in ...

    African Journals Online (AJOL)

    Retention of children under 18 months testing HIV positive in care in Swaziland: a retrospective study. ... children within the first two months of life and linking them into care. However, as time progresses the retention of children in care declines. Innovative strategies need to be developed to enhance patient retention.

  2. [Blood pressure in 6- to 45-month-old children. Apropos of a study of 264 children from nurseries].

    Science.gov (United States)

    Bérard, E; Boutté, P; Macone, F; Albertini, M; Mariani, R

    1988-03-01

    The systolic, diastolic and mean blood pressure and pulse rate were measured among 264 children aged 6 to 45 months, during routine check-up in 4 day-nurseries. We took the mean value of 3 successive measurements taken at one minute intervals on the upper arm of calm, asymptomatic children, with an automatic oscillometric monitor (Dinamap). When the mean systolic blood pressure was greater than 110 mmHg, the measurement was repeated. The results were related to weight, height and age and to personal and/or family history. The systolic pressure was steady with a 97th percentile at 110 mmHg. The diastolic pressure presented two levels: 97th percentile at 81 mmHg before 24 months and 73 mmHg afterwards. Nine children born to toxemic mothers, and 14 having required neonatal hospital care, had lower diastolic pressure. The other family or personal data were not linked to particular pressure groups.

  3. Patterns in blood pressure medication use in US incident dialysis patients over the first 6 months

    NARCIS (Netherlands)

    St Peter, Wendy L.; Sozio, Stephen M.; Shafi, Tariq; Ephraim, Patti L.; Luly, Jason; McDermott, Aidan; Bandeen-Roche, Karen; Meyer, Klemens B.; Crews, Deidra C.; Scialla, Julia J.; Miskulin, Dana C.; Tangri, Navdeep; Jaar, Bernard G.; Michels, Wieneke M.; Wu, Albert W.; Boulware, L. Ebony

    2013-01-01

    Several observational studies have evaluated the effect of a single exposure window with blood pressure (BP) medications on outcomes in incident dialysis patients, but whether BP medication prescription patterns remain stable or a single exposure window design is adequate to evaluate effect on

  4. Effects of aging and gender on micro-rheology of blood in 3 to 18 months old male and female Wistar (Crl:WI) rats.

    Science.gov (United States)

    Somogyi, Viktoria; Peto, Katalin; Deak, Adam; Tanczos, Bence; Nemeth, Norbert

    2018-01-01

    Age- and gender-related alterations of hemorheological parameters have not been completely elucidated to date. Experiments on older animals may give valuable information on this issue. However, the majority of rheological studies have been performed in young rodents. We aimed to investigate the influence of aging and gender on hemorheological parameters in rats. Coeval male (n=10) and female (n=10) Wistar (Crl:WI) rats were followed-up over 15 months. Blood samples were obtained from the lateral tail vein at 3, 4, 5, 9, 12, 15 and 18 months of age. Hematological parameters, red blood cell deformability (elongation under shear), osmotic gradient deformability and erythrocyte aggregation were tested. Body weight and the estrus cycle (in females) were also examined. Erythrocyte aggregation showed age- and gender-related variations. Red blood cell deformability was greater in females and gradually decreased over the 15-month period in both genders. Erythrocyte aggregation was greater in male rats at most ages, but did not show consistent changes with age. The micro-rheological parameters showed age-related alterations with gender differences. The effect of the estrous cycle cannot be excluded in female rats. The results provide reference data for studies of aging in rats and of the mechanism related to age and gender differences in hemorheology.

  5. Vaccination and blood sampling acceptability during Ramadan fasting month: A cross-sectional study in Conakry, Guinea.

    Science.gov (United States)

    Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim

    2017-05-02

    There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.

  6. 12-month blood pressure results of catheter-based renal artery denervation for resistant hypertension: the SYMPLICITY HTN-3 trial.

    Science.gov (United States)

    Bakris, George L; Townsend, Raymond R; Flack, John M; Brar, Sandeep; Cohen, Sidney A; D'Agostino, Ralph; Kandzari, David E; Katzen, Barry T; Leon, Martin B; Mauri, Laura; Negoita, Manuela; O'Neill, William W; Oparil, Suzanne; Rocha-Singh, Krishna; Bhatt, Deepak L

    2015-04-07

    Results of the SYMPLICITY HTN-3 (Renal Denervation in Patients With Uncontrolled Hypertension) trial confirmed the safety but not the efficacy of renal denervation for treatment-resistant hypertension at 6 months post procedure. This study sought to analyze the 12-month SYMPLICITY HTN-3 results for the original denervation group, the sham subjects who underwent denervation after the 6-month endpoint (crossover group), and the sham subjects who did not undergo denervation after 6 months (non-crossover group). Eligible subjects were randomized 2:1 to denervation or sham procedure. Subjects were unblinded to their treatment group after the 6-month primary endpoint was ascertained; subjects in the sham group meeting eligibility requirements could undergo denervation. Change in blood pressure (BP) at 12 months post randomization (6 months for crossover subjects) was analyzed. The 12-month follow-up was available for 319 of 361 denervation subjects and 48 of 101 non-crossover subjects; 6-month denervation follow-up was available for 93 of 101 crossover subjects. In denervation subjects, the 12-month office systolic BP (SBP) change was greater than that observed at 6 months (-15.5 ± 24.1 mm Hg vs. -18.9 ± 25.4 mm Hg, respectively; p = 0.025), but the 24-h SBP change was not significantly different at 12 months (p = 0.229). The non-crossover group office SBP decreased by -32.9 ± 28.1 mm Hg at 6 months, but this response regressed to -21.4 ± 19.9 mm Hg (p = 0.01) at 12 months, increasing to 11.5 ± 29.8 mm Hg. These data support no further reduction in office or ambulatory BP after 1-year follow-up. Loss of BP reduction in the non-crossover group may reflect decreased medication adherence or other related factors. (Renal Denervation in Patients With Uncontrolled Hypertension [SYMPLICITY HTN-3]; NCT01418261). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Fecal Occult Blood Test (FOBT): MedlinePlus Lab Test Information

    Science.gov (United States)

    ... caused by a variety of conditions, including: Polyps Hemorrhoids Diverticulosis Ulcers Colitis , a type of inflammatory bowel ... on a fecal occult blood test include ulcers, hemorrhoids, polyps, and benign tumors. If your test results ...

  8. Fecal Occult Blood Test and Gastrointestinal Parasitic Infection

    Directory of Open Access Journals (Sweden)

    Majed H. Wakid

    2010-01-01

    Full Text Available Stool specimens of 1238 workers in western region of Saudi Arabia were examined for infection with intestinal parasites and for fecal occult blood (FOB to investigate the possibility that enteroparasites correlate to occult intestinal bleeding. Direct smears and formal ether techniques were used for detection of diagnostic stages of intestinal parasites. A commercially available guaiac test was used to detect fecal occult blood. 47.01% of the workers were infected with intestinal parasites including eight helminthes species and eight protozoan species. The results provided no significant evidence (P-value=0.143 that intestinal parasitic infection is in association with positive guaiac FOB test.

  9. Reproducibility of ambulatory blood pressure values and circadian blood pressure patterns in untreated subjects in a 1-11 month interval.

    Science.gov (United States)

    Monte, Miguel; Cambão, Mariana; Mesquita Bastos, José; Polónia, Jorge

    2015-11-01

    To evaluate in untreated subjects the reproducibility of mean values and four circadian patterns between two ambulatory blood pressure monitoring (ABPM) recordings separated by 1-11 months. We performed a retrospective analysis of 481 individuals (59% women) evaluated by ABPM on two occasions, visit 1 (V1) and 2 (V2), separated by 5.5+0.2 months. Four circadian patterns were defined by night/day systolic blood pressure (SBP) ratios: reverse dippers (RD), ratio >1.0; non-dippers (ND), ratio 0.9-1.0; dippers (D), ratio 0.8-patterns were calculated by the percentage of the same profile from V1 to V2. Mean 24-h blood pressure (BP) at V1 and V2 was 126.8/75.9±0.5/0.5 vs. 126.5/75.7±0.5/0.4 mmHg (NS). Nighttime SBP fall was 9.8±0.4 (V1) and 9.6±0.3% (V2) (NS). The correlation coefficient of ABPM data at V1 vs. at V2 was 0.41-0.69 (ppatterns. Copyright © 2015 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  10. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  11. Participation in blood glucose test, knowledge and prevalence of ...

    African Journals Online (AJOL)

    Background: Diabetes mellitus causes great health complications which include cardiovascular diseases and nerve damage. Aim: To ascertain the participation in blood glucose test, knowledge of diabetes mellitus (DM) and prevalence of hyperglycemia among traders at New market, Enugu State. Methods: The study is a ...

  12. Changing the Price of Marriage: Evidence from Blood Test Requirements

    Science.gov (United States)

    Buckles, Kasey; Guldi, Melanie; Price, Joseph

    2011-01-01

    We use state repeals of blood test requirements (BTRs) for a marriage license that occurred between 1980 and 2008 to examine the impact of changes in the price of marriage on the marriage decision. Using a within-group estimator that holds constant state and year effects and exploits variation in the repeal dates of BTRs across states, we find…

  13. Reduction in unnecessary red blood cell folate testing by restricting computerized physician order entry in the electronic health record.

    Science.gov (United States)

    MacMillan, Thomas E; Gudgeon, Patrick; Yip, Paul M; Cavalcanti, Rodrigo B

    2018-05-02

    Red blood cell folate is a laboratory test with limited clinical utility. Previous attempts to reduce physician ordering of unnecessary laboratory tests, including folate, have resulted in only modest success. The objective of this study was to assess the effectiveness and impacts of restricting red blood cell folate ordering in the electronic health record. This was a retrospective observational study from January 2010 to December 2016 at a large academic healthcare network in Toronto, Canada. All inpatients and outpatients who underwent at least 1 red blood cell folate or vitamin B12 test during the study period were included. Red blood cell folate ordering was restricted to clincians in gastroenterology and hematology and was removed from other physicians' computerized order entry screen in the electronic health record in June 2013. Red blood cell folate testing decreased by 94.4% during the study, from a mean of 493.0 (SD 48.0) tests/month before intervention to 27.6 (SD 10.3) tests/month after intervention (P<.001). Restricting red blood cell folate ordering in the electronic health record resulted in a large and sustained reduction in red blood cell folate testing. Significant cost savings estimated at over a quarter-million dollars (CAD) over three years were achieved. There was no significant clinical impact of the intervention on the diagnosis of folate deficiency. Copyright © 2018. Published by Elsevier Inc.

  14. Hair sheep blood, citrated or defibrinated, fulfills all requirements of blood agar for diagnostic microbiology laboratory tests.

    Science.gov (United States)

    Yeh, Ellen; Pinsky, Benjamin A; Banaei, Niaz; Baron, Ellen Jo

    2009-07-03

    Blood agar is used for the identification and antibiotic susceptibility testing of many bacterial pathogens. In the developing world, microbiologists use human blood agar because of the high cost and inhospitable conditions for raising wool sheep or horses to supply blood. Many pathogens either fail to grow entirely or exhibit morphologies and hemolytic patterns on human blood agar that confound colony recognition. Furthermore, human blood can be hazardous to handle due to HIV and hepatitis. This study investigated whether blood from hair sheep, a hardy, low-maintenance variety of sheep adapted for hot climates, was suitable for routine clinical microbiology studies. Hair sheep blood obtained by jugular venipuncture was anticoagulated by either manual defibrination or collection in human blood bank bags containing citrate-phosphate-dextrose. Trypticase soy 5% blood agar was made from both forms of hair sheep blood and commercial defibrinated wool sheep blood. Growth characteristics, colony morphologies, and hemolytic patterns of selected human pathogens, including several streptococcal species, were evaluated. Specialized identification tests, including CAMP test, reverse CAMP test, and satellite colony formation with Haemophilus influenzae and Abiotrophia defectiva were also performed. Mueller-Hinton blood agar plates prepared from the three blood types were compared in antibiotic susceptibility tests by disk diffusion and E-test. The results of all studies showed that blood agar prepared from citrated hair sheep blood is suitable for microbiological tests used in routine identification and susceptibility profiling of human pathogens. The validation of citrated hair sheep blood eliminates the labor-intensive and equipment-requiring process of manual defibrination. Use of hair sheep blood, in lieu of human blood currently used by many developing world laboratories and as an alternative to cost-prohibitive commercial sheep blood, offers the opportunity to

  15. Hair sheep blood, citrated or defibrinated, fulfills all requirements of blood agar for diagnostic microbiology laboratory tests.

    Directory of Open Access Journals (Sweden)

    Ellen Yeh

    Full Text Available BACKGROUND: Blood agar is used for the identification and antibiotic susceptibility testing of many bacterial pathogens. In the developing world, microbiologists use human blood agar because of the high cost and inhospitable conditions for raising wool sheep or horses to supply blood. Many pathogens either fail to grow entirely or exhibit morphologies and hemolytic patterns on human blood agar that confound colony recognition. Furthermore, human blood can be hazardous to handle due to HIV and hepatitis. This study investigated whether blood from hair sheep, a hardy, low-maintenance variety of sheep adapted for hot climates, was suitable for routine clinical microbiology studies. METHODS AND FINDINGS: Hair sheep blood obtained by jugular venipuncture was anticoagulated by either manual defibrination or collection in human blood bank bags containing citrate-phosphate-dextrose. Trypticase soy 5% blood agar was made from both forms of hair sheep blood and commercial defibrinated wool sheep blood. Growth characteristics, colony morphologies, and hemolytic patterns of selected human pathogens, including several streptococcal species, were evaluated. Specialized identification tests, including CAMP test, reverse CAMP test, and satellite colony formation with Haemophilus influenzae and Abiotrophia defectiva were also performed. Mueller-Hinton blood agar plates prepared from the three blood types were compared in antibiotic susceptibility tests by disk diffusion and E-test. CONCLUSIONS: The results of all studies showed that blood agar prepared from citrated hair sheep blood is suitable for microbiological tests used in routine identification and susceptibility profiling of human pathogens. The validation of citrated hair sheep blood eliminates the labor-intensive and equipment-requiring process of manual defibrination. Use of hair sheep blood, in lieu of human blood currently used by many developing world laboratories and as an alternative to cost

  16. Polymerase chain reaction and blood culture in blood donors screened by ELISA test for Chagas' disease

    Directory of Open Access Journals (Sweden)

    Andréa Tieko Kinoshita-Yanaga

    2011-03-01

    Full Text Available The objective of this study was to evaluate, through blood culture and PCR, the results of the ELISA for Chagas' disease in the screening of blood donors in the public blood-supply network of the state of Paraná, Brazil, and to map the epidemiological profile of the donors with respect to their risk of infection by Trypanosoma cruzi. The negative and positive results of the ELISA were confirmed by blood culture and PCR for 190/191 individuals (99.5%. For one individual (0.5%, the ELISA was inconclusive, blood culture and IIF were negative, and IHA and PCR positive. Three individuals (1.6% were positive for T. cruzi on all the tests. Donors were predominantly female, and natives of Paraná, of rural origin, had observed or been informed of the presence of the vector in the municipalities where they resided, had never received a blood transfusion, had donated blood 1 to 4 times, and reported no cases of Chagas' disease in their families. We concluded that PCR and blood culturing have excellent potential for confirming the results of the ELISA, and that candidate blood donors with negative or positive tests have a similar risk of infection by T. cruzi, indicating that the ELISA test is sufficiently safe for screening blood prior to use.O objetivo deste estudo foi avaliar, pela hemocultura e PCR, os resultados do teste ELISA utilizado para doença de Chagas na triagem de doadores de sangue na rede pública do Estado do Paraná, Brasil, e traçar o perfil epidemiológico dos doadores quanto ao risco de infecção pelo Trypanosoma cruzi. Os resultados negativos e positivos do ELISA foram confirmados pela hemocultura e PCR em 190/191 indivíduos (99,5%. Para um indivíduo (0,5%, o teste de ELISA foi inconclusivo, hemocultura e IFI foram negativas, HAI e PCR foram positivas. Três indivíduos (1,6% foram positivos para T. cruzi em todos os testes. A maioria dos doadores era do sexo feminino, oriundos do Estado do Paraná, de origem rural, tinham

  17. Differential Effects of Acetylcholinesterase Inhibitors on Clinical Responses and Cerebral Blood Flow Changes in Patients with Alzheimer's Disease: A 12-Month, Randomized, and Open-Label Trial

    Directory of Open Access Journals (Sweden)

    Soichiro Shimizu

    2015-04-01

    Full Text Available Background/Aims: The present study evaluated the differences in treatment outcomes and brain perfusion changes among 3 types of acetylcholinesterase inhibitors (AchEIs, i.e. donepezil, rivastigmine, and galantamine. Methods: This was a prospective, longitudinal, randomized, open-label, 3-arm (donepezil, rivastigmine, or galantamine, parallel-group, 12-month clinical trial carried out in 55 patients with AD. Results: At 6 months, the results of the Mini-Mental State Examination (MMSE and the Trail Making Test (TMT-Part A showed an improvement versus baseline in the donepezil treatment group. All groups showed a significant increase in regional cerebral blood flow (rCBF, mainly in the frontal lobe. Significant rCBF reduction was observed in the temporal lobe and cingulate gyrus in all 3 groups. Conclusion: AchEI treatment prevents the progression of cognitive impairment and increases the relative rCBF in the frontal lobe.

  18. Test results of six-month test of two water electrolysis systems

    Science.gov (United States)

    Mills, E. S.; Wells, G. W.

    1972-01-01

    The two water electrolysis systems used in the NASA space station simulation 90-day manned test of a regenerative life support system were refurbished as required and subjected to 26-weeks of testing. The two electrolysis units are both promising systems for oxygen and hydrogen generation and both needed extensive long-term testing to evaluate the performance of the respective cell design and provide guidance for further development. Testing was conducted to evaluate performance in terms of current, pressure, variable oxygen demands, and orbital simulation. An automatic monitoring system was used to record, monitor and printout performance data at one minute, ten minute or one-hour intervals. Performance data is presented for each day of system operation for each module used during the day. Failures are analyzed, remedial action taken to eliminate problems is discussed and recommendations for redesign for future space applications are stated.

  19. Blood Culture (For Parents)

    Science.gov (United States)

    ... Metabolic Panel (BMP) Blood Test: Complete Blood Count Basic Blood Chemistry Tests Getting a Blood Test (Video) Blood Test: Basic Metabolic Panel Blood Test: Comprehensive Metabolic Panel Blood ...

  20. Analysis of daily quality assurance tests for tomotherapy and two Varian linear accelerators - three months review

    International Nuclear Information System (INIS)

    Kushwaha, Pratishtha; Jaiswal, Deeksha; Dheera, A.; Upreti, Udita; Chaudhari, Suresh; Kinhikar, Rajesh; Deshpande, Deepak; Shrivastava, Shyam

    2016-01-01

    Daily quality assurance (QA) for high precision radiotherapy equipments is very important to maintain the mechanical and dosimetric accuracy for patient treatments. Gross deviations in these parameters may have an adverse impact on the delivery of the treatments to patients. We report the results of daily QA tests performed over a period of three months for two Varian linear accelerators and a Tomotherapy machine

  1. National STD Awareness Month and GYT: Get Yourself Tested PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2011-03-03

    April is National STD Awareness Month. In this PSA, native communities, especially adolescents and young adults, are encouraged to get educated, tested, and treated by visiting gytnow.org.  Created: 3/3/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention.   Date Released: 3/3/2011.

  2. Emergency department blood alcohol level associates with injury factors and six-month outcome after uncomplicated mild traumatic brain injury.

    Science.gov (United States)

    Yue, John K; Ngwenya, Laura B; Upadhyayula, Pavan S; Deng, Hansen; Winkler, Ethan A; Burke, John F; Lee, Young M; Robinson, Caitlin K; Ferguson, Adam R; Lingsma, Hester F; Cnossen, Maryse C; Pirracchio, Romain; Korley, Frederick K; Vassar, Mary J; Yuh, Esther L; Mukherjee, Pratik; Gordon, Wayne A; Valadka, Alex B; Okonkwo, David O; Manley, Geoffrey T

    2017-11-01

    The relationship between blood alcohol level (BAL) and mild traumatic brain injury (mTBI) remains in need of improved characterization. Adult patients suffering mTBI without intracranial pathology on computed tomography (CT) from the prospective Transforming Research and Clinical Knowledge in Traumatic Brain Injury Pilot study with emergency department (ED) Glasgow Coma Scale (GCS) 13-15 and recorded blood alcohol level (BAL) were extracted. BAL≥80-mg/dl was set as proxy for excessive use. Multivariable regression was performed for patients with six-month Glasgow Outcome Scale-Extended (GOSE; functional recovery) and Wechsler Adult Intelligence Scale Processing Speed Index Composite Score (WAIS-PSI; nonverbal processing speed), using BAL≥80-mg/dl and GOSE≤7; 38.1% vs. 11.5%; p=0.025) and lower WAIS-PSI (92.4±12.7, 30th-percentile vs. 105.1±11.7, 63rd-percentile; pGOSE≤7 and an adjusted mean decrease of 8.88-points (95% CI [0.67-17.09]; p=0.035) on WAIS-PSI. Day-of-injury BAL>80-mg/dl after uncomplicated mTBI was associated with decreased GCS score and prolongation of reported LOC. BAL may be a biomarker for impaired return to baseline function and decreased nonverbal processing speed at six-months postinjury. Future confirmatory studies are needed. Published by Elsevier Ltd.

  3. The reliability of sickling and solubility tests and peripheral blood ...

    African Journals Online (AJOL)

    The reliability of sickling and solubility tests and peripheral blood film method for sickle cell disease screening at district health centers in Uganda. ... Les 200 prélèvements des enfants ages de 6 mois à 5 ans ont été analysés de façon indépendante en utilisant la méthode des analyses d'hématies falciformes, la solubilité et ...

  4. Implementation of immunochemical faecal occult blood test in general practice

    DEFF Research Database (Denmark)

    Juul, Jakob Søgaard; Bro, Flemming; Hornung, Nete

    2016-01-01

    anvendelsen af immunochemical faecal occult blood test (iFOBT) i almen praksis. iFOBT detekterer humant globin i fæces og indikerer gastrointestinal blødning. Studiet udgør en del af et ph.d.-studie, der bidrager med ny viden til at optimere udredningen af patienter med tarmkræft. Der er et stort behov...

  5. Management of blood donors and blood donations from individuals found to have a positive direct antiglobulin test.

    Science.gov (United States)

    Hannon, Judith L

    2012-04-01

    The medical literature is replete with articles addressing the diagnosis and management of patients with a positive direct antiglobulin test (DAT). However, there is scant information addressing the management of blood donors and blood donations found to have a positive DAT. Practices vary considerably between countries and blood suppliers within countries, and there is no standardized approach to the management of these blood donors or the blood products prepared from their donations. Recent evidence from Israel suggests that the finding of a positive DAT in a blood donor may not be as benign as previously thought. Therefore, it may be prudent for blood collection agencies to periodically reexamine their approach to the management of blood donors with a positive DAT and their donations. This article reviews the available literature and explores options for the management of DAT-positive blood donors and their blood donations. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Urine Test Strips to Exclude Cerebral Spinal Fluid Blood

    Directory of Open Access Journals (Sweden)

    Marshall, Robin A

    2011-02-01

    Full Text Available Introduction: Determining the presence or absence of red blood cells (RBC or their breakdown products in cerebrospinal fluid (CSF is essential for the evaluation of subarachnoid hemorrhage (SAH in headache patients. Current methodology for finding blood in the CSF is either spectrophotometric detection of pigment, which is time consuming and labor intensive, or visual assesment of samples for color change (xanthochromia, which is inaccurate. Bayer Multistix® urine test strips are designed to test urine for RBC by detecting the presence of hemoglobin. The aim of this pilot study was to evaluate the perfomance of urine reagent test strips for ruling out the presence of RBC in CSF.Methods: We compared color changes on Multistix® urine test strips to the standard of spectrophotometric absorbtion at 415nm and initial RBC counts in 138 visually clear CSF samples.Results: We performed Pearson Chi-Square and likelihood ratios on the results and found a correlation between a negative result on the urine test strip and less than 5 RBC per high power field and a spectrophotometric absorbance of less than 0.02% at 415nm in a CSF sample.Conclusion: These results warrant further investigation in the form of a prospective clinical validation as it may alter the emergency department evaluation for SAH. [West J Emerg Med. 2011;12(1:63-66.

  7. A comparison of blood alcohol levels as determined by breath and blood tests taken in actual field operations.

    Science.gov (United States)

    1972-01-01

    During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...

  8. Blood lipids and adipokines concentrations during a 6-month nutritional and physical activity intervention for metabolic syndrome treatment

    Directory of Open Access Journals (Sweden)

    Courteix Daniel

    2010-12-01

    Full Text Available Abstract Background To report changes in body weight, total and central fat mass, metabolic, hormonal and inflammatory parameters in overweight people who participated in a six months weight loss intervention associating diet management and exercise. Subjects and Methods Fourteen subjects (10 M, 4 F, mean age 62.9 ± 6.9 years, BMI 30.4+/- 3.8 kg/m2 presenting the characteristics of the Metabolic Syndrome (MS were included in the survey. They followed a three weeks (D0 to D20 cure in a medical establishment and a six months (D20 to M3 and M6 follow up at home. During the cure, they receive a balanced diet corresponding to 500 Kcal deficit vs their dayly energy expenditure (DEE and they exercised 2 to 3 hours per day. At D0, D20, M3 and M6, body composition (lean mass, total and central fat mass was analyzed with DEXA, blood pressure was taken and blood was collected to evaluate glycaemia, triglycerides, total, LDL and HDL cholesterol, insulin, leptin and adiponectin levels, CRP and pro-inflammatory interleukines IL1, IL.6 and TNFalpha. Results All parameters listed above except the cytokine were improved at D20, so that 4 subjects among 14 still presented the MS. After returning to home, these parameters remained stable. Conclusion The efficacy of therapeutic lifestyle modifications with education and exercise and diet was demonstrated, but the compliance to the new healthy lifestyle initiated during the cure was not optimal.

  9. Evaluation of the localization auditory screening test in children 6-18 months of age.

    Science.gov (United States)

    Tillis, C H; Grimm, W A

    1978-01-01

    The present paper is a report of a project to develop an automated auditory screening test for infants six to 18 months of age. The first year of the project was devoted to developing equipment and test procedures; the second year was concerned with testing the effectiveness of the equipment and procedures on an actual population of six to 18 month old infants. Two-hundred and fifty infants were screened auditorily as part of a county health department child development clinic. The pass/fail results of the screening test were evaluated in terms of physical and developmental examination following the screening and by means of a case review of the child's previous history. The results indicate that the procedure under investigation can be used to differentiate the normal hearing infant from the infant with possible hearing problems. It is shown by the test environment in which this study was conducted that the procedure reported can be successfully incorporated into a public health program, i.e., child development clinics or EPSDT programs.

  10. Is tuberculin testing before BCG vaccination necessary for children over three months of age?

    LENUS (Irish Health Repository)

    Hennessy, B

    2008-03-01

    In July 2007 Irish national policy changed such that children aged 3 months to 6 years no longer routinely require tuberculin (Mantoux) skin testing prior to BCG vaccination. Previous to that a tuberculin test was required in all children in this age group pre vaccination. While the previous policy was in place this study was conducted to assess the value of this test. The observation that children are frightened by the test (an injection into the skin) prompted the study. The author conducted a retrospective study of the results of 1,854 tuberculin tests performed as a prerequisite to BCG vaccination and found that only 0.7% of children had a positive test result (induration > 5mm). None of 107 children < 6 years of age tested positive. Those > 12 years were more likely to test positive than younger children (1.09% vs 0.4% respectively, p < 0.05). This study suggests that testing young children before BCG vaccination has a low yield of positive results and adds little to the detection of latent or active TB.

  11. White blood cell count, absolute neutrophil count, as predictors of hidden bacterial infections in febrile children 1-18 months of age without focus

    International Nuclear Information System (INIS)

    AL-Majali, R.M.

    2004-01-01

    Objectives: To study the relationship between White Blood Cell (WBC), Absolute Neutrophil Count (ANC) in febrile children 1-18 months of age as predictor of bacterial infection, so as to improve our predictability of bacterial infections in emergency room to decrease unnecessary admissions and antibiotic use. Methods: Retrospective review was performed on febrile patients 1-18 months of age that were admitted to hospital between August 2002 and March 2003 on the presumptive diagnosis of fever without focus, Complete septic work up was done for all patients according to local hospital protocol including Complete blood count (CBC), blood culture, urine culture, Chest X-Ray (CXR) and lumbar puncture, Patients who had history of antibiotics use within 48 hours of admission were excluded from the study, History, physical examination, laboratory and radiology data were reviewed. Data about the age, sex, temperature, presence or absence of focal bacterial infection, WBC, ANC, CXR report and body fluid culture results were collected and analyzed. Results: Thirty-four patients were reviewed in this study, Eight patients (23.5%) had bacterial infection: classified as group (2 patchy pneumonia, 3 Urinary tract infection (UTI), 2 meningitis, 1 Occult bacteremia (OB) and 26 patients (76.5%) had no evidence of bacterial infection, classified as group 2, No significant difference was found between the two groups in respect to age, sex, temperature and WBC P>0.05, while there was a significant difference between the two groups in respect to the ANC P = 0.02, also ANC had better sensitivity (78%) and specificity (89%) than WBC (sensitivity 77%, specificity 62%). Conclusion: ANC is a good predictive test for determining bacterial infection in young febrile children without focus, However there is need for other more reliable rapid cost effective measures in dealing with young febrile children at emergency department. (author)

  12. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...

  13. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  14. The Seasonal KPSS Test: Examining Possible Applications with Monthly Data and Additional Deterministic Terms

    Directory of Open Access Journals (Sweden)

    Ghassen El Montasser

    2015-05-01

    Full Text Available The literature has been notably less definitive in distinguishing between finite sample studies of seasonal stationarity than in seasonal unit root tests. Although the use of seasonal stationarity and unit root tests is advised to determine correctly the most appropriate form of the trend in a seasonal time series, such a use is rarely noted in the relevant studies on this topic. Recently, the seasonal KPSS test, with a null hypothesis of no seasonal unit roots, and based on quarterly data, has been introduced in the literature. The asymptotic theory of the seasonal KPSS test depends on whether data have been filtered by a preliminary regression. More specifically, one may proceed to extracting deterministic components, such as the mean and trend, from the data before testing. In this paper, we examine the effects of de-trending on the properties of the seasonal KPSS test in finite samples. A sketch of the test’s limit theory is subsequently provided. Moreover, a Monte Carlo study is conducted to analyze the behavior of the test for a monthly time series. The focus on this time-frequency is significant because, as we mentioned above, it was introduced for quarterly data. Overall, the results indicated that the seasonal KPSS test preserved its good size and power properties. Furthermore, our results corroborate those reported elsewhere in the literature for conventional stationarity tests. These subsequent results assumed that the nonparametric corrections of residual variances may lead to better in-sample properties of the seasonal KPSS test. Next, the seasonal KPSS test is applied to a monthly series of the United States (US consumer price index. We were able to identify a number of seasonal unit roots in this time series. [1] [1]    Table 1 in this paper is copyrighted and initially published by JMASM in 2012, Volume 11, Issue 1, pp. 69–77, ISSN: 1538–9472, JMASM Inc., PO Box 48023, Oak Park, MI 48237, USA, ea@jmasm.com.

  15. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  16. Evaluation of the effect of presence of blood in the stomach on endoscopic diagnostic tests for Helicobacter pylori infection

    Directory of Open Access Journals (Sweden)

    S Mittal

    2011-01-01

    Full Text Available Introduction: Presence of blood in the stomach has been thought to affect the performance of diagnostic tests used in detecting Helicobacter pylori (H. pylori in the stomach. This study evaluated the effect of blood on the efficacy of rapid urease test (RUT and microscopic appearance of the biopsy after staining with Giemsa stain. Materials and Methods: Patients with bleeding oesophageal varices who met the inclusion criteria were tested for H. pylori by RUT and microscopic examination of the biopsy. A repeat endoscopy, RUT and histology were done one month following initial presentation. The performance of the diagnostic tests was evaluated with and without the presence of intraluminal blood. A combined result of the two tests, RUT and histology, carried out in presence or absence of blood for the diagnosis of H. pylori, when considered together was considered as the gold standard. Results: Thirty six patients included in the study were in the ages ranging between 15-60 years (mean age = 44.14 years ±2.1. The combination of tests at both visits showed 20/36 (55.6% patients were positive for H. pylori. The decrease in H. pylori positivity in the presence of blood was significant for RUT (8.3% vs. 38.9%; P=0.005 and combined test (19.4% vs. 47.2%; P=0.02 but the decrease in positivity for histology (11.1% vs 30.6% was not significant (P=0.08. In the presence of blood, the sensitivity of RUT, histology and combined tests were 15%, 20% and 35%, respectively. In the absence of blood, the sensitivity of RUT, histology and combination of tests was 70%, 55% and 85%, respectively. Conclusion: Blood in the stomach significantly decreased the sensitivity of RUT, histology and the combination of both. Negative results of these tests in acute upper gastro intestinal (GI bleeding should therefore be interpreted carefully.

  17. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...

  18. Uptake of a colorectal cancer screening blood test in people with elevated risk for cancer who cannot or will not complete a faecal occult blood test.

    Science.gov (United States)

    Symonds, Erin L; Cock, Charles; Meng, Rosie; Cole, Stephen R; Fraser, Robert J L; Young, Graeme P

    2017-03-31

    Participation rates in colorectal cancer (CRC) screening programmes using faecal occult blood tests (FOBTs) are low. Nonparticipation is commonly attributed to psychosocial factors, but some medical conditions also prevent screening. These barriers might be partially overcome if a blood test for CRC screening was available. This study determined whether people who had always declined screening by FOBT would participate if offered a blood test. An audit of registrants within a personalized CRC screening programme was undertaken to determine the reasons for regular nonparticipation in FOBT. Consistent nonparticipants (n=240) were randomly selected and invited for CRC screening with a blood test. Demographic characteristics and the reasons for prior FOBT nonparticipation were collected by means of a questionnaire. Nonparticipation in the screening programme could be classified as either behavioural (8.6%), with consistent noncompliance, or due to medical contraindications (8.5%), which included chronic rectal bleeding, being deemed unsuitable by a health professional, and needing personal assistance. Blood test uptake was 25%, with participation in the medical contraindications group greater than that in the behavioural group (43 vs. 12%, Pprocrastination and dislike of the test, but these were not associated with blood test uptake (P>0.05). There is a subgroup of the community who have medical reasons for nonparticipation in CRC screening with FOBT but will participate if offered a blood test. The option of a blood test does not, however, improve uptake in those who admit to behavioural reasons for noncompliance with screening.

  19. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  20. Months backward test: A review of its use in clinical studies.

    Science.gov (United States)

    Meagher, James; Leonard, Maeve; Donoghue, Laura; O'Regan, Niamh; Timmons, Suzanne; Exton, Chris; Cullen, Walter; Dunne, Colum; Adamis, Dimitrios; Maclullich, Alasdair J; Meagher, David

    2015-09-22

    To review the use of the Months Backwards Test (MBT) in clinical and research contexts. We conducted a systematic review of reports relating to the MBT based upon a search of PsychINFO and MEDLINE between January 1980 and December 2014. Only reports that specifically described findings pertaining to the MBT were included. Findings were considered in terms of rating procedures, testing performance, psychometric properties, neuropsychological studies and use in clinical populations. We identified 22 data reports. The MBT is administered and rated in a variety of ways with very little consistency across studies. It has been used to assess various cognitive functions including focused and sustained attention as well as central processing speed. Performance can be assessed in terms of the ability to accurately complete the test without errors ("MB accuracy"), and time taken to complete the test ("MB duration"). Completion time in cognitively intact subjects is usually upper limits of 60-90 s typically applied in studies. The majority of cognitively intact adults can complete the test without error such that any errors of omission are strongly suggestive of cognitive dysfunction. Coverage of clinical populations, including those with significant cognitive difficulties is high with the majority of subjects able to engage with MBT procedures. Performance correlates highly with other cognitive tests, especially of attention, including the digit span backwards, trailmaking test B, serial threes and sevens, tests of simple and complex choice reaction time, delayed story recall and standardized list learning measures. Test-retest and inter-rater reliability are high (both > 0.90). Functional magnetic resonance imaging studies comparing the months forward test and MBT indicate greater involvement of more complex networks (bilateral middle and inferior frontal gyri, the posterior parietal cortex and the left anterior cingulate gyrus) for backwards cognitive processing. The MBT

  1. BloodLink: Computer-based Decision Support for Blood Test Ordering; Assessment of the effect on physicians' test-ordering behavior

    NARCIS (Netherlands)

    M.A.M. van Wijk (Marc)

    2000-01-01

    textabstractRequesting blood tests is an important aspect of the health care delivered by the general practitioner in The Netherlands. About three to four percent of the patients encounters with Dutch general practitioners result in the physician requesting blood tests, which is lower than in many

  2. Association of blood eosinophils and plasma periostin with FEV1 response after 3-month inhaled corticosteroid and long-acting beta2-agonist treatment in stable COPD patients.

    Science.gov (United States)

    Park, Hye Yun; Lee, Hyun; Koh, Won-Jung; Kim, Seonwoo; Jeong, Ina; Koo, Hyeon-Kyoung; Kim, Tae-Hyung; Kim, Jin Woo; Kim, Woo Jin; Oh, Yeon-Mok; Sin, Don D; Lim, Seong Yong; Lee, Sang-Do

    2016-01-01

    COPD patients with increased airway eosinophilic inflammation show a favorable response to inhaled corticosteroids (ICS) in combination with a long-acting bronchodilator. Recent studies have demonstrated a significant correlation of sputum eosinophilia with blood eosinophils and periostin. We investigated whether high blood eosinophils and plasma periostin were associated with an improvement in forced expiratory volume in 1 second (FEV1) after 3-month treatment with ICS/long-acting beta2-agonist (LABA) in stable COPD patients. Blood eosinophils and plasma periostin levels were measured in 130 stable COPD subjects selected from the Korean Obstructive Lung Disease cohort. Subjects began a 3-month ICS/LABA treatment after washout period. High blood eosinophils (>260/µL, adjusted odds ratio =3.52, P=0.009) and high plasma periostin (>23 ng/mL, adjusted odds ratio =3.52, P=0.013) were significantly associated with FEV1 responders (>12% and 200 mL increase in FEV1 from baseline after treatment). Moreover, the addition of high blood eosinophils to age, baseline positive bronchodilator response, and FEV1 eosinophils and high plasma periostin were associated with improved lung function after 3-month ICS/LABA treatment. In particular, high blood eosinophils, in combination with age and baseline lung function parameters, might be a possible biomarker for identification of COPD patients with favorable FEV1 improvement in response to ICS/LABA treatment.

  3. Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.

    Science.gov (United States)

    Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V

    2017-07-01

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2  = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Basketball ability testing and category for players with mental retardation: 8-month training effect.

    Science.gov (United States)

    Franciosi, Emanuele; Gallotta, Maria Chiara; Baldari, Carlo; Emerenziani, Gian Pietro; Guidetti, Laura

    2012-06-01

    Although sport for athletes with mental retardation (MR) is achieving an important role, the literature concerning basketball tests and training is still poor. The aims of this study were to verify whether the basketball test battery could be an appropriate modality to classify the players in the Promotion (Pro) category, to assess basketball abilities before (PRE) and after (POST) an 8-month training in players with MR in relation to Competitive (Comp) and Pro categories, to analyze the variation of specific basketball abilities based on subjects' MR diagnosis. Forty-one male basketball players with MR (17 Comp and 24 Pro; age range 18-45 years; MR: 15% mild, 54% moderate, 29% severe, and 2% profound) were assessed PRE and POST training through the basketball test battery, which assessed 4 ability levels of increasing difficulty (from I to IV), each one characterized by the analysis of fundamental areas (ball handling, reception, passing, and shooting). Level I was significantly changed after the intervention period regardless of the Category, whereas shooting was affected by the interaction between Category and Intervention. The results showed significant differences between categories in the scores of individual global, level I, level II, level III, and in all fundamental areas. Individual global score in both categories significantly increased. The players of Comp significantly improved in level III, in ball handling, reception, passing, and shooting scores. The players of Pro improved significantly in level II, in ball handling, reception, and passing scores. Individual global, ability levels I-III, and fundamental area scores were negatively correlated to the MR level indicating that the players with a lower MR obtained higher ability scores. In conclusion, it was found that the basketball test battery could be useful for improving and monitoring training in both Comp and Pro players.

  5. HIV RNA and proviral HIV DNA can be detected in semen after 6 months of antiretroviral therapy although HIV RNA is undetectable in blood.

    Science.gov (United States)

    Du, Peiwei; Liu, An; Jiao, Yanmei; Liu, Cuie; Jiang, Taiyi; Zhu, Weijun; Zhu, Yunxia; Wu, Hao; Sun, Lijun

    2016-03-01

    The risk of sexual transmission of HIV is strongly correlated with amounts of genital HIV RNA. Few studies have reported amounts of HIV RNA and HIV DNA in semen in HIV-infected Chinese patients undergoing antiviral treatment (ART). In this observational study, the amounts of HIV RNA and HIV DNA in semen were assessed after six months of ART in HIV-infected Chinese individuals, when HIV RNA was undetectable in blood . This study included 19 HIV-infected Chinese men undergoing ART for six months. Amounts of HIV in paired semen and blood samples were assessed using real-time PCR. The C2-V5 region of the HIV envelope (env) genes was cloned and sequenced and genotype and co-receptor usage predicted based on the sequence. It was found that HIV RNA was undetectable in the plasma of most patients (17/19), whereas HIV RNA could be detected in the semen of most patients (16/19). HIV DNA could be detected in both semen and blood. Genetic diversity of HIV between the seminal and blood compartments was identified. Thus, amounts of HIV RNA and HIV DNA remain high in semen of HIV-infected Chinese patients after six months of ART treatment, even when HIV RNA was undetectable in blood. © 2016 The Societies and John Wiley & Sons Australia, Ltd.

  6. Proficiency testing materials for pH and blood gases. The California Thoracic Society experience.

    Science.gov (United States)

    Hansen, J E; Clausen, J L; Levy, S E; Mohler, J G; Van Kessel, A L

    1986-02-01

    The California Thoracic Society Blood Gas Proficiency Testing Program distributed ampules from three separate lots of quality control products every three months as unknowns to participating clinical (survey) laboratories and ten selected reference laboratories. For eight quarters, aqueous buffers were distributed. For each lot, PCO2 and pH measurements varied within narrow ranges between laboratories. Concurrently, the PO2 measurements varied widely between reference laboratories as well as survey laboratories, but varied minimally when repeatedly assessed on each reference laboratory machine. Change to a fluorocarbon-containing emulsion as a testing medium resulted in a significant reduction in within model and overall variability for PO2. We attribute this reduction in variability to the higher O2 content and decreased temperature sensitivity for PO2 of the fluorocarbon-containing emulsion. Because we have no evidence that the magnitude of the interinstrument differences in PO2 found with these materials would be found with fresh human blood we recommend that regulatory agencies use the results of proficiency testing for PO2 cautiously.

  7. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Halfon, Philippe; Bacq, Yannick; De Muret, Anne; Penaranda, Guillaume; Bourliere, Marc; Ouzan, Denis; Tran, Albert; Botta, Danielle; Renou, Christophe; Bréchot, Marie-Claude; Degott, Claude; Paradis, Valérie

    2007-03-01

    We evaluated the test performance profile (TPP) of blood tests of liver fibrosis. Three hundred and fifty-six patients with C chronic hepatitis were included in two centers. Metavir staging of liver specimens by two independent pathologists and the following tests were evaluated: Fibrotest (FT), APRI, FibroMeter (FM), and Hepascore (HS). Metavir stages were: F0: 4%, F1: 55%, F2: 26%, F3: 11%, and F4: 4%. The AUROCs were not significantly different, respectively, FT, FM, APRI, HS: >or=F2: 0.79, 0.78, 0.76, >or=0.76; F3: 0.81, 0.85, 0.81, 0.81; and F4: 0.86, 0.94, 0.92, 0.89. The TPP relies on the paired comparison of blood-test misclassification based on liver specimen, e.g. FT vs FM, respectively: F0+1: 18 vs 28% (p=0.0003), >or=F2: 43 vs 31% (p=0.004). There was no center effect. In those populations, the four blood tests had a similar performance for significant fibrosis (F>or=2), lying in the lower range of published results which is attributable to a low >or=F2 prevalence, and for >or=F3 and F4. However, FM and FT had performance profiles significantly different as a function of fibrosis stages or diagnostic target (fibrosis cut-off). This has to be considered during the interpretation process. Moreover, the performance should be reported with different diagnostic targets.

  8. Comparison of the sensitivity of typhi dot test with blood culture in typhoid

    Energy Technology Data Exchange (ETDEWEB)

    Rizvi, Q [Hamdard College of Medicine, Karachi (Pakistan). Dept. of Pharmacology

    2006-10-15

    To evaluate the sensitivity of Typhi Dot test in comparison to Blood Culture for the diagnosis of Typhoid Fever in our setup. Fifty patients who fulfilled the clinical criteria of having Typhoid Fever. The data of all the patients was documented, and they were submitted to the Typhi Dot and Blood Culture tests, apart from other routine investigations. Out of the total 50 patients, 47(94%) had their Blood Culture positive for Typhoid bacillus, while in 49 (98%) the Typhi Dot test was positive. Two patients which were found positive on Typhi dot test, gave negative results on Blood Culture. One patient with the signs and symptoms of Typhoid Fever was found neither positive on Typhi Dot test nor upon Blood Culture. There was no significant difference between the results of Blood Culture and Typhi Dot test in the diagnosis of Typhoid Fever. However, Typhi Dot has the advantages of being less expensive and quicker in giving results with excellent sensitivity. (author)

  9. Comparison of the sensitivity of typhi dot test with blood culture in typhoid

    International Nuclear Information System (INIS)

    Rizvi, Q.

    2006-01-01

    To evaluate the sensitivity of Typhi Dot test in comparison to Blood Culture for the diagnosis of Typhoid Fever in our setup. Fifty patients who fulfilled the clinical criteria of having Typhoid Fever. The data of all the patients was documented, and they were submitted to the Typhi Dot and Blood Culture tests, apart from other routine investigations. Out of the total 50 patients, 47(94%) had their Blood Culture positive for Typhoid bacillus, while in 49 (98%) the Typhi Dot test was positive. Two patients which were found positive on Typhi dot test, gave negative results on Blood Culture. One patient with the signs and symptoms of Typhoid Fever was found neither positive on Typhi Dot test nor upon Blood Culture. There was no significant difference between the results of Blood Culture and Typhi Dot test in the diagnosis of Typhoid Fever. However, Typhi Dot has the advantages of being less expensive and quicker in giving results with excellent sensitivity. (author)

  10. Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report October 2014

    Energy Technology Data Exchange (ETDEWEB)

    Ogden, Dan [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report October 2014 Highlights • Rory Kennedy, Dan Ogden and Brenden Heidrich traveled to Germantown October 6-7, for a review of the Infrastructure Management mission with Shane Johnson, Mike Worley, Bradley Williams and Alison Hahn from NE-4 and Mary McCune from NE-3. Heidrich briefed the group on the project progress from July to October 2014 as well as the planned path forward for FY15. • Jim Cole gave two invited university seminars at Ohio State University and University of Florida, providing an overview of NSUF including available capabilities and the process for accessing facilities through the peer reviewed proposal process. • Jim Cole and Rory Kennedy co-chaired the NuMat meeting with Todd Allen. The meeting, sponsored by Elsevier publishing, was held in Clearwater, Florida, and is considered one of the premier nuclear fuels and materials conferences. Over 340 delegates attended with 160 oral and over 200 posters presented over 4 days. • Thirty-one pre-applications were submitted for NSUF access through the NE-4 Combined Innovative Nuclear Research Funding Opportunity Announcement. • Fourteen proposals were received for the NSUF Rapid Turnaround Experiment Summer 2014 call. Proposal evaluations are underway. • John Jackson and Rory Kennedy attended the Nuclear Fuels Industry Research meeting. Jackson presented an overview of ongoing NSUF industry research.

  11. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  12. Estimation of the Blood Pressure Response With Exercise Stress Testing.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Ballard, Emma L; Scalia, Gregory M

    2018-04-20

    The blood pressure response to exercise has been described as a significant increase in systolic BP (sBP) with a smaller change in diastolic BP (dBP). This has been documented in small numbers, in healthy young men or in ethnic populations. This study examines these changes in low to intermediate risk of myocardial ischaemia in men and women over a wide age range. Consecutive patients having stress echocardiography were analysed. Ischaemic tests were excluded. Manual BP was estimated before and during standard Bruce protocol treadmill testing. Patient age, sex, body mass index (BMI), and resting and peak exercise BP were recorded. 3200 patients (mean age 58±12years) were included with 1123 (35%) females, and 2077 males, age range 18 to 93 years. Systolic BP increased from 125±17mmHg to 176±23mmHg. The change in sBP (ΔsBP) was 51mmHg (95% CI 51,52). The ΔdBP was 1mmHg (95% CI 1, 1), from 77 to 78mmHg, p<0.001). The upper limit of normal peak exercise sBP (determined by the 90th percentile) was 210mmHg in males and 200mmHg in females. The upper limit of normal ΔsBP was 80mmHg in males and 70mmHg in females. The lower limit of normal ΔsBP was 30mmHg in males and 20mmHg in females. In this large cohort, sBP increased significantly with exercise. Males had on average higher values than females. Similar changes were seen with the ΔsBP. The upper limit of normal for peak exercise sBP and ΔsBP are reported by age and gender. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  13. Histological analysis and identification of spermatogenesis-related genes in 2-, 6-, and 12-month-old sheep testes

    Science.gov (United States)

    Bai, Man; Sun, Limin; Zhao, Jia; Xiang, Lujie; Cheng, Xiaoyin; Li, Jiarong; Jia, Chao; Jiang, Huaizhi

    2017-10-01

    Testis development and spermatogenesis are vital factors that influence male animal fertility. In order to identify spermatogenesis-related genes and further provide a theory basis for finding biomarkers related to male sheep fertility, 2-, 6-, and 12-month-old Small Tail Han Sheep testes were selected to investigate the dynamic changes of sheep testis development. Hematoxylin-eosin routine staining and RNA-Seq technique were used to perform histological and transcriptome analysis for these testes. The results showed that 630, 102, and 322 differentially expressed genes (DEGs) were identified in 2- vs 6-month-old, 6- vs 12-month-old, and 2- vs 12-month-old testes, respectively. GO and KEGG analysis showed the following: DEGs in 2- vs 6-month-old testes were mainly related to the GO terms of sexual maturation and the pathways of multiple metabolism and biosynthesis; in 6- vs 12-month-old testes, most of the GO terms that DEGs involved in were related to metabolism and translation processes; the most significantly enriched pathway is the ribosome pathway. The union of DEGs in 2- vs 6-month-old, 6- vs 12-month-old, and 2- vs 12-month-old testes was categorized into eight profiles by series cluster. Subsequently, the eight profiles were classified into four model profiles and four co-expression networks were constructed based on the DEGs in these model profiles. Finally, 29 key regulatory genes related to spermatogenesis were identified in the four co-expression networks. The expression of 13 DEGs (CA3, APOH, MYOC, CATSPER4, SYT6, SERPINA10, DAZL, ADIPOR2, RAB13, CEP41, SPAG4, ODF1, and FRG1) was validated by RT-PCR.

  14. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  15. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  16. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  17. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions

    Directory of Open Access Journals (Sweden)

    Celia G. Walker

    2015-08-01

    Full Text Available Eicosapentaenoic acid (EPA and docosahexaenoic acid (DHA are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA is correspondingly decreased, the effect on other fatty acids (FA is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0–4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA multinomial regression analysis was used to identify important FA changes for plasma phosphatidylcholine (PC, cholesteryl ester (CE and triglyceride (TAG and for blood mononuclear cells (MNC, red blood cells (RBC and platelets (PLAT. Dose-dependent increases in EPA + DHA were matched by decreases in several n-6 polyunsaturated fatty acids (PUFA in PC, CE, RBC and PLAT, but were predominantly compensated for by oleic acid in TAG. Changes were observed for all FA classes in MNC. Consequently the n-6:n-3 PUFA ratio was reduced in a dose-dependent manner in all pools after 12 months (37%–64% of placebo in the four portions group. We conclude that the profile of the FA decreased in exchange for the increase in EPA + DHA following supplementation differs by FA pool with implications for understanding the impact of n-3 PUFA on blood lipid and blood cell biology.

  18. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions.

    Science.gov (United States)

    Walker, Celia G; West, Annette L; Browning, Lucy M; Madden, Jackie; Gambell, Joanna M; Jebb, Susan A; Calder, Philip C

    2015-08-03

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA) is correspondingly decreased, the effect on other fatty acids (FA) is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0-4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA) multinomial regression analysis was used to identify important FA changes for plasma phosphatidylcholine (PC), cholesteryl ester (CE) and triglyceride (TAG) and for blood mononuclear cells (MNC), red blood cells (RBC) and platelets (PLAT). Dose-dependent increases in EPA + DHA were matched by decreases in several n-6 polyunsaturated fatty acids (PUFA) in PC, CE, RBC and PLAT, but were predominantly compensated for by oleic acid in TAG. Changes were observed for all FA classes in MNC. Consequently the n-6:n-3 PUFA ratio was reduced in a dose-dependent manner in all pools after 12 months (37%-64% of placebo in the four portions group). We conclude that the profile of the FA decreased in exchange for the increase in EPA + DHA following supplementation differs by FA pool with implications for understanding the impact of n-3 PUFA on blood lipid and blood cell biology.

  19. Whiteboard Icons to Support the Blood-Test Process in an Emergency Department

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten; From, Gustav

    2013-01-01

    The competent treatment of emergency department (ED) patients requires an effective and efficient process for handling laboratory tests such as blood tests. This study investigates how ED clinicians go about the process, from ordering blood tests to acknowledging their results and, specifically......, assesses the use of whiteboard icons to support this process. On the basis of observation and interviews we find that the blood-test process is intertwined with multiple other temporal patterns in ED work. The whiteboard icons, which indicate four temporally distinct steps in the blood-test process......, support the nurses in maintaining the flow of patients through the ED and the physicians in assessing test results at timeouts. The main results of this study are, however, that the blood-test process is temporally and collaboratively complex, that the whiteboard icons pass by most of this complexity...

  20. Evaluation and enhancement of medical knowledge competency by monthly tests: a single institution experience.

    Science.gov (United States)

    Khan, Abdur Rahman; Siddiqui, Nauman Saleem; Thotakura, Raja; Hasan, Syed Shafae; Luni, Faraz Khan; Sodeman, Thomas; Hinch, Bryan; Kaw, Dinkar; Hariri, Imad; Khuder, Sadik; Assaly, Ragheb

    2015-01-01

    In-training examination (ITE) has been used as a predictor of performance at the American Board of Internal Medicine (ABIM) certifying examination. ITE however may not be an ideal modality as it is held once a year and represents snapshots of performance as compared with a trend. We instituted monthly tests (MTs) to continually assess the performance of trainees throughout their residency. To determine the predictors of ABIM performance and to assess whether the MTs can be used as a tool to predict passing the ABIM examination. The MTs, core competencies, and ITE scores were analyzed for a cohort of graduates who appeared for the ABIM examination from 2010 to 2013. Logistic regression was performed to identify the predictors of a successful performance at the ABIM examination. Fifty-one residents appeared for the ABIM examination between 2010 and 2013 with a pass rate of 84%. The MT score for the first year (odds ratio [OR] =1.302, CI =1.004-1.687, P=0.04) and second year (OR =1.125, CI =1.004-1.261, P=0.04) were independent predictors of ABIM performance along with the second-year ITE scores (OR =1.248, CI =1.096-1.420, P=0.001). The MT is a valuable tool to predict the performance at the ABIM examination. Not only it helps in the assessment of likelihood of passing the certification examination, it also helps to identify those residents who may require more assistance earlier during their residency. It may also highlight the areas of weakness in program curriculum and guide curriculum development.

  1. Stripping Voltammetric Determination Of Zinc, Cadmium, Lead And Copper In Blood Samples Of Children Aged Between 3 Months And 6 years

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Mahajan

    2005-05-01

    Full Text Available Blood samples of 160 children, ranging age between 3 months and 6 years were selected from five different parts of Amritsar district of Punjab (India and were analyzed for Zn, Cd, Pb and Cu using anodic stripping voltammetry. Large variations in the results have been correlated to the area inhabited, age differences and other factors. It was found that the areas, more prone to environmental stress, had shown more quantities of these metals in blood samples in comparison to those which were taken from safer sites. Similarly the younger children lesser exposed to environmental pollution had shown comparatively lesser quantity of these metals in comparison to older objects.

  2. Weight, blood pressure, and dietary benefits after 12 months of a Web-based Nutrition Education Program (DASH for health): longitudinal observational study.

    Science.gov (United States)

    Moore, Thomas J; Alsabeeh, Nour; Apovian, Caroline M; Murphy, Megan C; Coffman, Gerald A; Cullum-Dugan, Diana; Jenkins, Mark; Cabral, Howard

    2008-12-12

    The dietary habits of Americans are creating serious health concerns, including obesity, hypertension, diabetes, cardiovascular disease, and even some types of cancer. While considerable attention has been focused on calorie reduction and weight loss, approaches are needed that will not only help the population reduce calorie intake but also consume the type of healthy, well-balanced diet that would prevent this array of medical complications. To design an Internet-based nutrition education program and to explore its effect on weight, blood pressure, and eating habits after 12 months of participation. We designed the DASH for Health program to provide weekly articles about healthy nutrition via the Internet. Dietary advice was based on the DASH diet (Dietary Approaches to Stop Hypertension). The program was offered as a free benefit to the employees of EMC Corporation, and 2834 employees and spouses enrolled. Enrollees voluntarily entered information about themselves on the website (food intake), and we used these self-entered data to determine if the program had any effect. Analyses were based upon the change in weight, blood pressure, and food intake between the baseline period (before the DASH program began) and the 12th month. To be included in an outcome, a subject had to have provided both a baseline and 12th-month entry. After 12 months, 735 of 2834 original enrollees (26%) were still actively using the program. For subjects who were overweight/obese (body mass index > 25; n = 151), weight change at 12 months was -4.2 lbs (95% CI: -2.2, -6.2; P Internet, with no person-to-person contact with health professionals, is associated with significant weight loss, blood pressure lowering, and dietary improvements after 12 months. Effective programs like DASH for Health, delivered via the Internet, can provide benefit to large numbers of subjects at low cost and may help address the nutritional public health crisis.

  3. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  4. African American community members sustain favorable blood pressure outcomes through 12-month telephone motivational interviewing (MI) maintenance

    Science.gov (United States)

    Community approaches offer promise for addressing disparities experienced by African Americans in hypertension prevalence, treatment, and control. HUB City Steps, a community-based participatory research lifestyle intervention, tracked participants through a 12-month MI maintenance phase following a...

  5. Can latent heat safely warm blood? – in vitro testing of a portable prototype blood warmer

    OpenAIRE

    McEwen, Mark P; Roxby, David

    2007-01-01

    Abstract Background Trauma/retrieval patients are often in shock and hypothermic. Treatment of such patients usually involves restoring their blood volume with transfusion of blood (stored at 2°C – 6°C) and/or crystalloids or colloids (stored at ambient temperature). Rapid infusion of these cold fluids can worsen or even induce hypothermia in these patients. Warming of intravenous fluids at accident sites has traditionally been difficult due to a lack of suitable portable fluid warmers that a...

  6. Measurement of endotoxin levels in blood of hemodialysis Patients by 'Lal' test and comparision of its efficacy with blood culture

    Directory of Open Access Journals (Sweden)

    Gh Vazirzadeh

    2006-01-01

    Full Text Available Introduction: Presently, bacteremia is the principal cause of morbidity in patients undergoing hemodialysis. Gram-negative bacteria account for approximately 50 percent of documented infections. Endotoxins released during lysis of gram negative bacteremia result in inflammatory and defense response by the body and if not treated promptly result in septic shock and ultimately death of the patient. This study describes the detection of endotoxins in blood of patients with bacteremia due to gram - negative bacteria by LAL test. Method: Blood samples of 278 hemodialysis patients were analyzed in this study and pathogens were isolated from blood culture samples. Then, their antibiotic sensitivity was determined. In patients with positive blood culture, endotoxin levels were measured by LAL-test. Results: Frequency of bacteremia in patients was 13.6% . The prevalence of gram – negative bacteremia was 44.7%. E coli were the major pathogens, while staphylococcus aureus was the most common gram positive bacterium. Endotoxin was detected in 15 patients (3.8 ± 1.08 EU/ml . The sensitivity and specificity of endotoxins for gram – negative bacteremia were 88% and 95%, respectively. Conclusion: The results indicate that the LAL method is a fast, sensitive and simple method. There was no significant difference between the results of blood culture and LAL – test ( P > 0.05 .

  7. Blood in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Hemoglobin, Urine; p. 325. Lab Tests ...

  8. The Pattern of Fatty Acids Displaced by EPA and DHA Following 12 Months Supplementation Varies between Blood Cell and Plasma Fractions

    OpenAIRE

    Walker, Celia G.; West, Annette L.; Browning, Lucy M.; Madden, Jackie; Gambell, Joanna M.; Jebb, Susan A.; Calder, Philip C.

    2015-01-01

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are increased in plasma lipids and blood cell membranes in response to supplementation. Whilst arachidonic acid (AA) is correspondingly decreased, the effect on other fatty acids (FA) is less well described and there may be site-specific differences. In response to 12 months EPA + DHA supplementation in doses equivalent to 0–4 portions of oily fish/week (1 portion: 3.27 g EPA+DHA) multinomial regression analysis was used to identify...

  9. Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report November 2014

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, Renae [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-11-01

    Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report November 2014 Highlights Rory Kennedy and Sarah Robertson attended the American Nuclear Society Winter Meeting and Nuclear Technology Expo in Anaheim, California, Nov. 10-13. ATR NSUF exhibited at the technology expo where hundreds of meeting participants had an opportunity to learn more about ATR NSUF. Dr. Kennedy briefed the Nuclear Engineering Department Heads Organization (NEDHO) on the workings of the ATR NSUF. • Rory Kennedy, James Cole and Dan Ogden participated in a reactor instrumentation discussion with Jean-Francois Villard and Christopher Destouches of CEA and several members of the INL staff. • ATR NSUF received approval from the NE-20 office to start planning the annual Users Meeting. The meeting will be held at INL, June 22-25. • Mike Worley, director of the Office of Innovative Nuclear Research (NE-42), visited INL Nov. 4-5. Milestones Completed • Recommendations for the Summer Rapid Turnaround Experiment awards were submitted to DOE-HQ Nov. 12 (Level 2 milestone due Nov. 30). Major Accomplishments/Activities • The University of California, Santa Barbara 2 experiment was unloaded from the GE-2000 at HFEF. The experiment specimen packs will be removed and shipped to ORNL for PIE. • The Terrani experiment, one of three FY 2014 new awards, was completed utilizing the Advanced Photon Source MRCAT beamline. The experiment investigated the chemical state of Ag and Pd in SiC shell of irradiated TRISO particles via X-ray Absorption Fine Structure (XAFS) spectroscopy. Upcoming Meetings/Events • The ATR NSUF program review meeting will be held Dec. 9-10 at L’Enfant Plaza. In addition to NSUF staff and users, NE-4, NE-5 and NE-7 representatives will attend the meeting. Awarded Research Projects Boise State University Rapid Turnaround Experiments (14-485 and 14-486) Nanoindentation and TEM work on the T91, HT9, HCM12A and 9Cr ODS specimens has been completed at

  10. Post-test probability for neonatal hyperbilirubinemia based on umbilical cord blood bilirubin, direct antiglobulin test, and ABO compatibility results.

    Science.gov (United States)

    Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan

    2016-05-01

    Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group

  11. For People of African, Mediterranean, or Southeast Asian Heritage: Important Information about Diabetes Blood Tests

    Science.gov (United States)

    ... Urodynamic Testing Virtual Colonoscopy Diabetes Blood Tests for People of African, Mediterranean, or Southeast Asian Descent Introduction ... care. What are some common hemoglobin variants? Most people have only one kind of hemoglobin, called hemoglobin ...

  12. Intraneural blood flow analysis during an intraoperative Phalen's test in carpal tunnel syndrome.

    Science.gov (United States)

    Yayama, Takafumi; Kobayashi, Shigeru; Awara, Kousuke; Takeno, Kenichi; Miyazaki, Tsuyoshi; Kubota, Masafumi; Negoro, Kohei; Baba, Hisatoshi

    2010-08-01

    Phalen's test has been one of the most significant of clinical signs when making a clinical diagnosis of idiopathic carpal tunnel syndrome (CTS). However, it is unknown whether intraneural blood flow changes during Phalen's test in patients with CTS. In this study, an intraoperative Phalen's test was conducted in patients with CTS to observe the changes in intraneural blood flow using a laser Doppler flow meter. During Phalen's test, intraneural blood flow showed a sharp decrease, which lasted for 1 min. Intraneural blood flow decreased by 56.7%-100% (average, 78.0%) in the median nerve relative to the blood flow before the test. At 1 min after completing the test, intraneural blood flow returned to the baseline value. After carpal tunnel release, there was no marked decrease in intraneural blood flow. This study demonstrated that the blood flow in the median nerve is reduced when Phalen's test is performed in vivo. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. ORIGINAL ARTICLES Solubility tests and the peripheral blood film ...

    African Journals Online (AJOL)

    2009-12-02

    Dec 2, 2009 ... screening for sickle-cell disease: A cost benefit analysis. Andrew Livex Okwi .... work and would be paid a monthly salary. • Glassware not falling ... weighing balance would depreciate at USh 300 000 and USh. 50 280 per year, ... normal life, and 85% with sickle cell anemia (SS) would live to adulthood if ...

  14. Monthly variation in faeces:blood concentration ratio of persistent organic pollutants over the first year of life: a case study of one infant

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yiqin, E-mail: y.chen16@uq.edu.au [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); McLachlan, Michael S. [Department of Environmental Science and Analytical Chemistry (ACES), Stockholm University (Sweden); Kaserzon, Sarit; Wang, Xianyu; Weijs, Liesbeth; Gallen, Michael [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Toms, Leisa-Maree L. [School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Faculty of Health, Queensland University of Technology (Australia); Li, Yan [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Aylward, Lesa L. [The University of Queensland, National Research Centre for Environmental Toxicology (Australia); Summit Toxicology, LLP, Falls Church, VA (United States); Sly, Peter D. [Children’s Health and Environment Program, Queensland Children’s Medical Research Institute, Brisbane (Australia); Child Health Research Centre, The University of Queensland (Australia); Mueller, Jochen F. [The University of Queensland, National Research Centre for Environmental Toxicology (Australia)

    2016-05-15

    Previous studies have found that the concentrations of a range of persistent organic pollutants (POPs) in faeces is linearly proportional to the POP concentrations in blood of human adults irrespective of age and gender. In order to investigate the correlation between POP concentrations in faeces and blood in infants, the monthly variation of POP concentrations in faeces over the first year of life of one infant was investigated in this study and compared to modelled blood concentrations. Faecal samples were collected from one male infant daily. The samples were pooled by month and analysed for three selected POPs (2,2{sup ′},4,4{sup ′},5,5{sup ′}-Hexachlorobiphenyl (PCB153), p,p′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 2,2{sup ′},4,4′-tetrabromodiphenyl ether (BDE47)). The POP concentrations in faecal samples increased for the first four months by a factor of 2.9, 4.9 and 1.4 for PCB153, BDE47, and p,p′-DDE, respectively. The faecal concentrations of all POPs decreased rapidly following the introduction of formula and solid food to the diet and subsequent weaning of the infant. Further, a one-compartment model was developed to estimate the daily POP concentrations in the blood of the infant. The POP concentrations in blood were predicted to vary much less over the first year than those observed in faeces. The faeces:blood concentration ratio of selected POPs (K{sub fb}) differed significantly (P<0.0001) between the period before and after weaning, and observed changes in K{sub fb} are far greater than the uncertainty in the estimated K{sub fb}. A more stable K{sub fb} after weaning indicates the possibility of applying the stable K{sub fb} values for non-invasive assessment of internal exposure in infants after weaning. The intra-individual variation in K{sub fb} in infants is worthy of further investigation. - Highlights: • Measured POPs concentrations in faecal samples decreased rapidly following weaning. • Ratio of faecal:blood

  15. Monthly variation in faeces:blood concentration ratio of persistent organic pollutants over the first year of life: a case study of one infant

    International Nuclear Information System (INIS)

    Chen, Yiqin; McLachlan, Michael S.; Kaserzon, Sarit; Wang, Xianyu; Weijs, Liesbeth; Gallen, Michael; Toms, Leisa-Maree L.; Li, Yan; Aylward, Lesa L.; Sly, Peter D.; Mueller, Jochen F.

    2016-01-01

    Previous studies have found that the concentrations of a range of persistent organic pollutants (POPs) in faeces is linearly proportional to the POP concentrations in blood of human adults irrespective of age and gender. In order to investigate the correlation between POP concentrations in faeces and blood in infants, the monthly variation of POP concentrations in faeces over the first year of life of one infant was investigated in this study and compared to modelled blood concentrations. Faecal samples were collected from one male infant daily. The samples were pooled by month and analysed for three selected POPs (2,2 ′ ,4,4 ′ ,5,5 ′ -Hexachlorobiphenyl (PCB153), p,p′-dichlorodiphenyldichloroethylene (p,p′-DDE) and 2,2 ′ ,4,4′-tetrabromodiphenyl ether (BDE47)). The POP concentrations in faecal samples increased for the first four months by a factor of 2.9, 4.9 and 1.4 for PCB153, BDE47, and p,p′-DDE, respectively. The faecal concentrations of all POPs decreased rapidly following the introduction of formula and solid food to the diet and subsequent weaning of the infant. Further, a one-compartment model was developed to estimate the daily POP concentrations in the blood of the infant. The POP concentrations in blood were predicted to vary much less over the first year than those observed in faeces. The faeces:blood concentration ratio of selected POPs (K fb ) differed significantly (P<0.0001) between the period before and after weaning, and observed changes in K fb are far greater than the uncertainty in the estimated K fb . A more stable K fb after weaning indicates the possibility of applying the stable K fb values for non-invasive assessment of internal exposure in infants after weaning. The intra-individual variation in K fb in infants is worthy of further investigation. - Highlights: • Measured POPs concentrations in faecal samples decreased rapidly following weaning. • Ratio of faecal:blood concentrations (K fb ) changed over the first

  16. Midwifery basics. Antenatal care--blood tests in pregnancy.

    Science.gov (United States)

    Baston, Helen

    2002-12-01

    Joanna is now 16 weeks pregnant. She has been feeling particularly tired and her mum suggested that she might be anaemic. Louis is rather insulted as he prides himself on buying the best fresh ingredients from the local market, they love cooking and eat plenty of fruit and vegetables. Joanna had a full blood count taken by the community midwife who came to the flat to do her booking history. The midwife said that the surgery would contact her if she needed treatment for anaemia, but she hasn't heard anything yet.

  17. Investigations of blood ammonia analysis: Test matrices, storage, and stability.

    Science.gov (United States)

    Goldstein, Brittany N; Wesler, Jordan; Nowacki, Amy S; Reineks, Edmunds; Natowicz, Marvin R

    2017-06-01

    An assessment of blood ammonia concentration is common medical practice in the evaluation of an individual with an unexplained mental status change or coma. The determination of a blood ammonia level is most commonly done using a glutamate dehydrogenase (GLDH)-based assay, although there are many potential sources of artifact and the literature is inconsistent regarding key preanalytic issues. Using a GLDH-based assay, we first investigated matrix effects using three anticoagulants: heparin, EDTA and oxalate. Heparin-anticoagulated plasma was substantially less precise than EDTA- and oxalate-anticoagulated plasma. Oxalate-anticoagulated plasma showed a greater baseline of apparent ammonia than either heparin- or EDTA-derived plasma, presumably due to interferants. We then evaluated the stability of EDTA-anticoagulated plasma for assessment of ammonia when stored at 4°C,-14°C or -70°C. There was a linear increase of ammonia with storage at both 4°C and -14°C. Plasma kept at -70°C for up to three weeks showed no change in measured ammonia relative to the baseline determination. This work clarifies preanalytic conditions for which a precise determination of ammonia can be accomplished using a GLDH-based assay. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  19. West Nile virus blood transfusion-related infection despite nucleic acid testing.

    Science.gov (United States)

    Macedo de Oliveira, Alexandre; Beecham, Brady D; Montgomery, Susan P; Lanciotti, Robert S; Linnen, Jeffrey M; Giachetti, Cristina; Pietrelli, Larry A; Stramer, Susan L; Safranek, Thomas J

    2004-12-01

    A case of West Nile virus (WNV) encephalitis associated with transfusion of blood that did not react when tested for WNV by minipool (MP) nucleic acid testing (NAT) is described. A Nebraska man developed clinical encephalitis 13 days after surgery and transfusion of 26 blood components. Antibody testing confirmed WNV infection. An investigation was initiated to determine the source of this infection. The patient's family members were interviewed to identify risk factors for WNV infection. Residual samples were retested for WNV RNA using transcription-mediated amplification (TMA) assay and two polymerase chain reaction (PCR) assays. Blood donors' follow-up serum samples were collected. All samples were tested for WNV-specific immunoglobulin M antibodies. The patient's family denied recent mosquito exposure. The 20 blood components collected after July 2003 did not react when tested for WNV in a six-member MP-NAT at the time of donation. Retrospective individual testing identified one sample as WNV-reactive by the TMA assay and one of the PCR assays. Seroconversion was demonstrated in the donor associated with this sample. WNV RNA detection by individual donation NAT demonstrates viremic blood escaping MP-NAT and supports transfusion-related WNV transmission. MP-NAT may not detect all WNV-infected blood donors, allowing WNV transmission to continue at low levels. WNV NAT assays might vary in sensitivity and pooling donations could further impact test performance. Understanding MP NAT limitations can improve strategies to maintain safety of the blood supply in the United States.

  20. Demographic, risk factors and motivations among blood donors with reactive serologic tests for syphilis in São Paulo, Brazil.

    Science.gov (United States)

    Ferreira, S C; de Almeida-Neto, C; Nishiya, A S; Oliveira, C D L; Ferreira, J E; Alencar, C S; Levi, J E; Salles, N A; Mendrone, A; Sabino, E C

    2014-06-01

    To identify the demographic characteristics, risk factors and motivations for donating among blood donors with reactive serologic tests for syphilis. Post-donation interviews with syphilis seropositive blood donors improve recruitment and screening strategies. This case-control study compares 75 Venereal Disease Research Laboratory (VDRL) > 8, EIA+ (enzyme immunoassay) and FTA-ABS+ (fluorescent treponemal antibody); 80 VDRL-, EIA+ and FTA-ABS+; and 34 VDRL- and EIA- donors between 2004 and 2009. Donors were assessed by their demographic characteristics, sexual behaviour, history of alcohol and illicit drugs use, and motivations to donate. Donors with VDRL > 8 were more likely to be divorced [AOR = 12·53; 95% confidence interval (CI) 1·30-120·81], to have had more than six sexual partners (AOR=7·1; 95% CI 1·12-44·62) and to report male-male-sex in the past 12 months (AOR=8·18; 95% CI 1·78-37·60). Donors with VDRL-, EIA+ and FTA-ABS+ were less likely to be female (AOR=0·26; 95% CI 0·07-0·96), more likely to be older (AOR=10·2; 95% CI 2·45-42·58 ≥ 39 and illicit drugs use; 30·7% (VDRL > 8) and 12·5% (VDRL-, EIA+ and FTA-ABS+) of donors reported that they had been at risk for HIV infection (P = 0·004). One-third of donors came to the blood bank to help a friend or a relative who needed blood. Although donors exposed to syphilis reported and recognised some high risk behaviour, most were motivated by direct appeal to donate blood. Monitoring the risk profile of blood donors can benefit public health and improve blood safety. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.

  1. Gingival crevicular blood for screening of blood glucose level in patients with & without diabetes: a chair-side test.

    Science.gov (United States)

    Bhavsar, M V; Brahmbhatt, N A; Sahayata, V; Bhavsar, N V

    2016-05-01

    Diabetes is a pandemic disease with increasing prevalence and serious complications. Periodontitis being one of its presentation and is its sixth recognized complication. This study compares blood glucose levels in gingival crevicular blood of patients with and without diabetes elicited during routine periodontal probing and venous blood sample. Seventy patients with moderate gingivitis and periodontitis positive for bleeding on probing were chosen. All the subjects were divided in two groups, group I consisted of 35 diabetic and group II of 35 non-diabetic subjects. Blood from the gingiva of the most inflamed site was collected with the test strip of a glucose self-monitoring device, and the blood glucose levels were measured. At the same time, intravenous blood was collected for measurement in a laboratory glucose analyzer. Gingival index and probing pocket depth were evaluated for each subject at same time. The mean GCB levels and VB derived from all samples were 156.07 ± 49.23 mg dl(-1) and 156 ± 49.89 mg dl(-1) , respectively, for diabetic group and 90.80 ± 11.07 and 93.41 ± 9.30 for non-diabetic group. In both the groups, the difference between GCB and VB glucose levels was non-significant (P > 0.005). Highly significant correlation between GCB and VB (r = 0.972 for diabetic and r = 0.721 for non-diabetic) in both the groups was found. The data from this study show that GCB collected during diagnostic periodontal examination can be an excellent source for estimation of blood sugar or glucometric analysis. This technique is also suitable for routine screening of diabetic and early diagnosis of unknown diabetic cases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Prognostic factors for hereditary cancer distress six months after BRCA1/2 or HNPCC genetic susceptibility testing

    NARCIS (Netherlands)

    van Oostrom, Iris; Meijers-Heijboer, Hanne; Duivenvoorden, Hugo J.; Brocker-Vriends, Annette H. J. T.; van Asperen, Christi J.; Sijmons, Rolf H.; Seynaeve, Caroline; Van Gool, Arthur R.; Klijn, Jan G. M.; Tibben, Aad

    This study explored predictors for hereditary cancer distress six months after genetic susceptibility testing for a known familial BRCA1/2 or HNPCC related mutation, in order to gain insight into aspects relevant for the identification of individuals needing additional psychosocial support. Coping,

  3. Marked increase in rat red blood cell membrane protein glycosylation by one-month treatment with a cafeteria diet

    Directory of Open Access Journals (Sweden)

    Laia Oliva

    2015-07-01

    Full Text Available Background and Objectives. Glucose, an aldose, spontaneously reacts with protein amino acids yielding glycosylated proteins. The compounds may reorganize to produce advanced glycosylation products, which regulatory importance is increasingly being recognized. Protein glycosylation is produced without the direct intervention of enzymes and results in the loss of function. Glycosylated plasma albumin, and glycosylated haemoglobin are currently used as index of mean plasma glucose levels, since higher glucose availability results in higher glycosylation rates. In this study we intended to detect the early changes in blood protein glycosylation elicited by an obesogenic diet.Experimental Design. Since albumin is in constant direct contact with plasma glucose, as are the red blood cell (RBC membranes, we analyzed their degree or glycosylation in female and male rats, either fed a standard diet or subjected to a hyper-energetic self-selected cafeteria diet for 30 days. This model produces a small increase in basal glycaemia and a significant increase in body fat, leaving the animals in the initial stages of development of metabolic syndrome. We also measured the degree of glycosylation of hemoglobin, and the concentration of glucose in contact with this protein, that within the RBC. Glycosylation was measured by colorimetric estimation of the hydroxymethylfurfural liberated from glycosyl residues by incubation with oxalate.Results. Plasma glucose was higher in cafeteria diet and in male rats, both independent effects. However, there were no significant differences induced by sex or diet in either hemoglobin or plasma proteins. Purified RBC membranes showed a marked effect of diet: higher glycosylation in cafeteria rats, which was more marked in females (not in controls. In any case, the number of glycosyl residues per molecule were higher in hemoglobin than in plasma proteins (after correction for molecular weight. The detected levels of glucose in

  4. ENLUB - 12 Months Technical Report WP3: Development of simulative tests

    DEFF Research Database (Denmark)

    Zhang, Wenqi

    A draw bead test has been developed at the Department of Manufacturing Engineering, The Technical University of Denmark. The purpose of the test equipment is to simulate an actual situation in industry where draw beads are applied to constrain movement of sheet material particular in stretch...

  5. Nanoscale Test Strips for Multiplexed Blood Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of our nanoscale test strips, or nanostrips, is to provide rapid, low-cost, powerful multiplexed analyses in a diminutive form so that whole body health...

  6. How-to-Do-It: A Simulation of the Blood Type Test.

    Science.gov (United States)

    Sharp, John D., Sr.; Smailes, Deborah L.

    1989-01-01

    Explains an activity that allows students to visualize antigen-antibody type reactions and learn about antibodies and antigens without performing blood typing tests. Provides directions for students and a comparison chart of a blood typing simulation with procedure which is based on the reactions of certain ionic solutions when mixed. (RT)

  7. Rapid prototyping of centrifugal microfluidic modules for point of care blood testing

    CSIR Research Space (South Africa)

    Madzivhandila, Phophi

    2016-11-01

    Full Text Available We present modular centrifugal microfluidic devices that enable a series of blood tests to be performed towards a full blood count. The modular approach allows for rapid prototyping of device components in a generic format to complete different...

  8. Carbon Dioxide (CO2) in Blood: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/carbondioxideco2inblood.html Carbon Dioxide (CO2) in Blood To use the sharing features ... this page, please enable JavaScript. What is a Carbon Dioxide (CO2) Blood Test? Carbon dioxide (CO2) is an ...

  9. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  10. The testing effect on skills learning might last 6 months

    DEFF Research Database (Denmark)

    Kromann, C B; Bohnstedt, C; Jensen, M L

    2009-01-01

    In a recent study we found that testing as a final activity in a skills course increases the learning outcome compared to spending an equal amount of time practicing. Whether this testing effect measured as skills performance can be demonstrated on long-term basis is not known. The research...... question was: does testing as a final activity in a cardio-pulmonary resuscitation (CPR) skills course increase learning outcome when assessed after half a year, compared to spending an equal amount of time practicing? The study was an assessor-blinded randomised controlled trial. A convenient sample of 7.......4. The difference between groups was not statistically significant, P = 0.06. This study suggests that testing as a final activity in a CPR skills course might have an effect on long-term learning outcome compared to spending an equal amount of time practicing the skills. Although this difference...

  11. [Development and evaluation of a pyrogen test based on human whole blood

    Science.gov (United States)

    Hartung, Thomas; Fennrich, Stefan; Fischer, Matthias; Montag-Lessing, Thomas; Wendel, Albrecht

    1998-01-01

    When cells of the immune system, especially blood monocytes and macrophages, come into contact with pyrogenic (fever-inducing) contaminations, they secrete messenger molecules which initiate an hyperthermic reaction in the organism. Of this group of endogenous pyrogens, most is known about interleukin-1 (IL-1). A new pyrogen test makes use of this reaction as a system for detection: The substances which are to be screened are incubated with a small volume of blood from a healthy donor. Any pyrogens present induce the production of IL-1 which can be detected by ELISA. This test has a higher sensitivity and is more economical than the conventional pyrogen test in rabbits and furthermore reflects the reaction of the relevant species. In contrast to the customary alternative method, the Limulus amoebocyte lysate test (LAL), this test is not restricted to endotoxins from Gram-negative bacteria and is also not hindered by substances which bind endotoxins, such as blood proteins, to the same extent. Consequently, more than 50 non-endotoxin pyrogens have already been traced by this test. The whole blood test is even superior to the LAL in regard to the detection of endotoxins: in a comparison of about 60 endotoxins, there was a correlation of the potency of the individual endotoxins between the whole blood test and the pyrogen test in rabbits, but neither test correlated with the LAL test. In some cases, endotoxins with equal effects in the LAL test differed in potency in the human blood model by a factor of 10 000. A method has been developed by which cryopreserved blood can be put to use in the test. In this way, blood donations from a donor can be pre-tested so that uniform material may be employed in the test. This test opens up entirely new perspectives on pyrogen testing for Gram-positive or fungal pyrogens as well as in medicinal products. In addition, it could fill the dangerous security gap which might result from the limitations of testing medications and blood

  12. Impact of a confirmatory RhD test on the correct serologic typing of blood donors

    Directory of Open Access Journals (Sweden)

    Luciana Cayres Schmidt

    2015-10-01

    Full Text Available BACKGROUND: The RHD gene is highly polymorphic, which results in a large number of RhD variant phenotypes. Discrepancies in RhD typing are still a problem in blood banks and increase the risk of alloimmunization. In this study, the RhD typing strategy at a blood bank in Brazil was evaluated.METHODS: One-hundred and fifty-two samples typed as RhD negative and C or E positive by routine tests (automated system and indirect antiglobulin test using the tube technique were reevaluated for RhD status by three methods. The method with the best performance was implemented and evaluated for a period of one year (n = 4897 samples. Samples that were D positive exclusively in the confirmatory test were submitted to molecular analysis.RESULTS: The gel test for indirect antiglobulin testing with anti-D immunoglobulin G (clone ESD1 presented the best results. Seventy samples (1.43% previously typed as RhD negative showed reactivity in the gel test for indirect antiglobulin testing and were reclassified as D positive. D variants that may cause alloimmunization, such as weak D type 2 and partial DVI, were detected.CONCLUSION: The confirmatory RhD test using the gel test for indirect antiglobulin testing represents a breakthrough in transfusion safety in this blood center. Our results emphasize the importance of assessing the blood group typing strategy in blood banks.

  13. Action Prediction Allows Hypothesis Testing via Internal Forward Models at 6 Months of Age

    Directory of Open Access Journals (Sweden)

    Gustaf Gredebäck

    2018-03-01

    Full Text Available We propose that action prediction provides a cornerstone in a learning process known as internal forward models. According to this suggestion infants’ predictions (looking to the mouth of someone moving a spoon upward will moments later be validated or proven false (spoon was in fact directed toward a bowl, information that is directly perceived as the distance between the predicted and actual goal. Using an individual difference approach we demonstrate that action prediction correlates with the tendency to react with surprise when social interactions are not acted out as expected (action evaluation. This association is demonstrated across tasks and in a large sample (n = 118 at 6 months of age. These results provide the first indication that infants might rely on internal forward models to structure their social world. Additional analysis, consistent with prior work and assumptions from embodied cognition, demonstrates that the latency of infants’ action predictions correlate with the infant’s own manual proficiency.

  14. Generalization of learning from picture books to novel test conditions by 18- and 24-month-old children.

    Science.gov (United States)

    Simcock, Gabrielle; Dooley, Megan

    2007-11-01

    Researchers know little about whether very young children can recognize objects originally introduced to them in a picture book when they encounter similar looking objects in various real-world contexts. The present studies used an imitation procedure to explore young children's ability to generalize a novel action sequence from a picture book to novel test conditions. The authors found that 18-month-olds imitated the action sequence from a book only when the conditions at testing matched those at encoding; altering the test stimuli or context disrupted imitation (Experiment 1A). In contrast, the 24-month-olds imitated the action sequence with changes to both the test context and stimuli (Experiment 1B). Moreover, although the 24-month-olds exhibited deferred imitation with no changes to the test conditions, they did not defer imitation with changes to the context and stimuli (Experiment 2). Two factors may account for the pattern of results: age-related changes in children's ability to utilize novel retrieval cues as well as their emerging ability to understand the representational nature of pictures. (c) 2007 APA.

  15. Estimation of 305 Day Milk Yield from Cumulative Monthly and Bimonthly Test Day Records in Indonesian Holstein Cattle

    Science.gov (United States)

    Rahayu, A. P.; Hartatik, T.; Purnomoadi, A.; Kurnianto, E.

    2018-02-01

    The aims of this study were to estimate 305 day first lactation milk yield of Indonesian Holstein cattle from cumulative monthly and bimonthly test day records and to analyze its accuracy.The first lactation records of 258 dairy cows from 2006 to 2014 consisted of 2571 monthly (MTDY) and 1281 bimonthly test day yield (BTDY) records were used. Milk yields were estimated by regression method. Correlation coefficients between actual and estimated milk yield by cumulative MTDY were 0.70, 0.78, 0.83, 0.86, 0.89, 0.92, 0.94 and 0.96 for 2-9 months, respectively, meanwhile by cumulative BTDY were 0.69, 0.81, 0.87 and 0.92 for 2, 4, 6 and 8 months, respectively. The accuracy of fitting regression models (R2) increased with the increasing in the number of cumulative test day used. The used of 5 cumulative MTDY was considered sufficient for estimating 305 day first lactation milk yield with 80.6% accuracy and 7% error percentage of estimation. The estimated milk yield from MTDY was more accurate than BTDY by 1.1 to 2% less error percentage in the same time.

  16. Evolution of cerebral blood flow between the acute stage and one month after a global transient amnesia: a study of 18 patients

    International Nuclear Information System (INIS)

    Philippon, B.; Houzard, C.; Cinotti, L.; Croisile, B.

    2001-01-01

    We studied 18 patients within 24 hours of an idiopathic transient global amnesia and one month later using 133 Xe et 99m Tc-HMPAO for CBF measurements. Absolute hemispheric CBF obtained with the 133 Xe were initially: (right) = 46.9 ml/mn/100 g (s.d 6.6) and (left) = 47.9 (s.d 6.8). One month later, a significant increase of the right hemispheric CBF occurred (52.0 ± 6.9). Accordingly, absolute CBF increased bilaterally in the cerebellar and temporal regions. Local relative cerebral blood flow ( 99m Tc-HMPAO) allowed to reinforce these findings with increased resolution. They can also provide quantitative values thanks to the 133 Xe calibration. (authors)

  17. [Flow cytometric test using eosin-5'-maleimide (EMA) labelling of red blood for diagnosis of hereditary spherocytosis].

    Science.gov (United States)

    Wang, Jiying; Zheng, Bin; Zhao, Yuping; Chen, Xuejing; Liu, Yan; Bo, Lijin; Zheng, Yizhou; Zhang, Fengkui; Ru, Kun; Wang, Huijun

    2015-07-01

    To investigate the sensitivity and specificity of eosin-5'-maleimide (EMA)assay for the diagnosis of hereditary spherocytosis (HS), and to verify the stability of reagent and samples. EMA flow cytometry test, NaCl-osmotic fragility test and acidified glycerol lysis test were performed using peripheral blood samples from 80 patients with HS and 44 patients with other blood diseases, the sensitivity and specificity of the three methods were compared, and the feasibility of EMA binding test was estimated. The stability of EMA reagent and HS samples stored at different temperatures were tested. Among the 124 tested samples, the sensitivity and specificity of EMA binding test was 0.925 and 0.954, that of NaCl-osmotic fragility test was 0.950 and 0.455, and that of acidified glycerol lysis test was 1.000 and 0.318, respectively. Although the sensitivity of NaCl-osmotic fragility test and acidified glycerol lysis test was a little higher than that of EMA binding test, the specificity of the former two methods was poor, they couldn't clearly distinguish whether spherocytosis is hereditary spherocytosis. The experiment results showed that EMA was sensitive to the temperature and should not be stored in a small aliquots at -80 ℃ over a period of 6 months. The stability of the HS sample was better, 6 days storage at 4 ℃ and 3 days storage at room temperature had no influence on the results. EMA binding test by flow cytometry showed good sensitivity and specificity for HS diagnosis. EMA reagent should be stored at-80 ℃ and the HS samples should be tested within 6 days storage at 4 ℃ and 3 days at room temperature.

  18. Home environment and cord blood levels of lead, arsenic, and zinc on neurodevelopment of 24 months children living in Chitwan Valley, Nepal.

    Science.gov (United States)

    Parajuli, Rajendra Prasad; Fujiwara, Takeo; Umezaki, Masahiro; Watanabe, Chiho

    2015-01-01

    In a birth cohort living in Chitwan Valley, lowland Nepal, we have previously reported inverse associations between in utero levels of lead (Pb), arsenic (As) and neurodevelopment at birth measured by the Brazelton Neonatal Behavioral Assessment Scale, third edition (NBAS III). In the present paper, a follow-up of the same cohort was made on 24-month-old infants regarding the neurodevelopmental effects of these metals, taking the postnatal environment into account. In total, the same100 mother-infant pairs as the previous study, whose Pb, As, and Zn concentrations in cord blood were known, were recruited. Postnatal raising environment was evaluated using the Home Observation for Measurement of Environment (HOME) scale. Neurodevelopment of children at 24 months of age (n=74) was assessed using the Bayley Scale of Infant Development, Second Edition (BSID II). Multivariable regression adjusting for covariates was performed to determine the associations of in utero levels of toxic and essential elements and the home environment with neurodevelopment scores. Unlike the NBAS III conducted for newborns, none of the BSID II cluster scores in 24-month-old infants were associated with cord blood levels of Pb, As, and Zn. The total HOME score was positively associated with the mental development scale (MDI) score (coefficient=0.67, at 95% CI=0.03 to 1.31). In this cohort, a detrimental effect of in utero Pb and As on neurodevelopmental indicators observed at birth disappeared at 24 months, while an association between neurodevelopment and home environment continued. Copyright © 2014 Elsevier GmbH. All rights reserved.

  19. Potential impact of the MR spectroscopic cancer blood test on reducing the need for lung biopsy

    International Nuclear Information System (INIS)

    Simon, M.; Fossel, E.T.

    1989-01-01

    Lung biopsies are generally performed to identify or rule out malignancy. A clinical presumption of lung malignancy without biopsy proof may result in unjustified surgery. The authors sought to test the value of the MR cancer blood test (CBT) recently described. They obtained prebiopsy blood samples (2 mL) from 65 patients undergoing lung biopsy for radiologically identified lesions. The CBT was performed blinded, and the result was then compared with the pathologic diagnosis obtained from biopsy. Results are presented

  20. Effect of bariatric surgery-induced weight loss on renal and systemic inflammation and blood pressure: a 12-month prospective study.

    Science.gov (United States)

    Fenske, Wiebke K; Dubb, Sukhpreet; Bueter, Marco; Seyfried, Florian; Patel, Karishma; Tam, Frederick W K; Frankel, Andrew H; le Roux, Carel W

    2013-01-01

    Bariatric surgery improves arterial hypertension and renal function; however, the underlying mechanisms and effect of different surgical procedures are unknown. In the present prospective study, we compared the 12-month follow-up results after Roux-en-Y gastric bypass, laparoscopic adjustable gastric banding, and laparoscopic sleeve gastrectomy on weight loss, hypertension, renal function, and inflammatory status. A total of 34 morbidly obese patients were investigated before, one and 12 months after Roux-en-Y gastric bypass (n = 10), laparoscopic adjustable gastric banding (n = 13), and laparoscopic sleeve gastrectomy (n = 11) for hypertension, kidney function, urinary and serum cytokine levels of macrophage migration inhibitory factor, monocyte chemotactic protein-1, and chemokine ligand-18. At 12 months after surgery, the patients in all 3 treatment arms showed a significant decrease in the mean body mass index, mean arterial pressure, and urinary and serum inflammatory markers (all P .8 mg/L) had a marked improvement in renal function 12 months after surgery (P < .05). Surgically induced weight loss is associated with a marked decrease in renal and systemic inflammation and arterial hypertension and improvement in renal function in patients with pre-existing renal impairment. These effects appear to be independent of surgical procedure. The improvement in renal inflammation could be 1 of the mechanisms contributing to the beneficial effects of bariatric surgery on arterial blood pressure, proteinuria, and renal function. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  1. Inappropriate use of the faecal occult blood test in a university hospital in the Netherlands

    NARCIS (Netherlands)

    van Rijn, Anne F.; Stroobants, An K.; Deutekom, Marije; Lauppe, Corinne; Sturk, Auguste; Bossuyt, Patrick M. M.; Fockens, Paul; Dekker, Evelien

    2012-01-01

    Objectives Although all international guidelines state that there is no indication to perform a faecal occult blood test (FOBT) in symptomatic patients, we believe the test is frequently used as a diagnostic test. The objective of this study was to investigate whether the current guidelines for FOBT

  2. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  3. Routine preoperative blood group and save testing is unnecessary for elective laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Tandon, A.; Shahzad, K.; Nunes, Q.; Shrotri, M.; Lunevicius, R.

    2017-01-01

    Background: Although the practice of preoperative testing of ABO group and Rh (D) type for elective cholecystectomy has deep historical roots, it is not evidence-based. We aimed to assess the preoperative blood group and save testing practice for a cohort of patients subjected to elective laparoscopic cholecystectomy for symptomatic cholecystolithiasis between January 2010 and October 2014. Methods: National Health Service (NHS) hospital based, surgical procedure-specific, retrospective study was conducted. A final group consisted of 2,079 adult patients. We estimated the incidence of perioperative blood transfusion attributable to laparoscopic cholecystectomy. The results of eight other studies are presented. Results: A preoperative blood group and save test was performed in 907 patients (43.6%), whereas cross-matching was documented in 28 patients (3.1%). None required an intraoperative blood transfusion. Twelve patients (0.58%) underwent blood transfusion postoperatively following laparoscopic cholecystectomy, of which ten were transfused due to severe intra-abdominal bleeding (0.48%). There were no deaths. Conclusions: The likelihood of blood transfusion attributable to elective laparoscopic cholecystectomy is 1:200. A routine preoperative blood group and save testing is unnecessary. It neither alters the management of severe hypovolemia, secondary to perioperative bleeding, nor does it lead to better outcomes. (author)

  4. Liver fibrosis diagnosis by blood test and elastography in chronic hepatitis C: agreement or combination?

    Science.gov (United States)

    Calès, P; Boursier, J; Lebigot, J; de Ledinghen, V; Aubé, C; Hubert, I; Oberti, F

    2017-04-01

    In chronic hepatitis C, the European Association for the Study of the Liver and the Asociacion Latinoamericana para el Estudio del Higado recommend performing transient elastography plus a blood test to diagnose significant fibrosis; test concordance confirms the diagnosis. To validate this rule and improve it by combining a blood test, FibroMeter (virus second generation, Echosens, Paris, France) and transient elastography (constitutive tests) into a single combined test, as suggested by the American Association for the Study of Liver Diseases and the Infectious Diseases Society of America. A total of 1199 patients were included in an exploratory set (HCV, n = 679) or in two validation sets (HCV ± HIV, HBV, n = 520). Accuracy was mainly evaluated by correct diagnosis rate for severe fibrosis (pathological Metavir F ≥ 3, primary outcome) by classical test scores or a fibrosis classification, reflecting Metavir staging, as a function of test concordance. Score accuracy: there were no significant differences between the blood test (75.7%), elastography (79.1%) and the combined test (79.4%) (P = 0.066); the score accuracy of each test was significantly (P tests. Classification accuracy: combined test accuracy (91.7%) was significantly (P blood test (84.1%) and elastography (88.2%); accuracy of each constitutive test was significantly (P tests but not with combined test: 89.0 vs. 92.7% (P = 0.118). Multivariate analysis for accuracy showed an interaction between concordance and fibrosis level: in the 1% of patients with full classification discordance and severe fibrosis, non-invasive tests were unreliable. The advantage of combined test classification was confirmed in the validation sets. The concordance recommendation is validated. A combined test, expressed in classification instead of score, improves this rule and validates the recommendation of a combined test, avoiding 99% of biopsies, and offering precise staging. © 2017 John Wiley & Sons Ltd.

  5. Association of blood lead levels in children 0-72 months with living in Mid-Appalachia: a semi-ecologic study.

    Science.gov (United States)

    Wiener, R Constance; Jurevic, Richard J

    2016-01-01

    Lead exposure in children remains a significant public health issue, although many advances have been made. The Mid-Appalachia area (Kentucky, New York, Ohio, Pennsylvania, and West Virginia) is 89-91% rural with a population density of 16-21 people/km2 (41-54 people/mi2). Mid-Appalachia has significant health disparities including concerns for the consequences of greater lead exposure to children due to mining and industrial footprints, and existing older housing. The purpose of this study is to compare the reported blood lead levels of screened children, aged 0-72 months in Mid-Appalachia, to the children in the USA in general. Data from the Centers for Disease Control and Prevention and from the US Census Bureau were analyzed in a semi-ecological study. The blood lead level of 5 μg/dL was compared between children in Mid-Appalachia and the US housing units built before 1950; US housing units built before 1940 were also compared. The number of children with blood lead levels of 5 μg/dL was significantly greater in Mid-Appalachia than nationally (7.75% vs 5.79%, respectively; pecological relationship with the number of homes built before 1950 and before 1940.

  6. Mobile diabetes intervention study: testing a personalized treatment/behavioral communication intervention for blood glucose control.

    Science.gov (United States)

    Quinn, Charlene C; Gruber-Baldini, Ann L; Shardell, Michelle; Weed, Kelly; Clough, Suzanne S; Peeples, Malinda; Terrin, Michael; Bronich-Hall, Lauren; Barr, Erik; Lender, Dan

    2009-07-01

    National data find glycemic control is within target (A1ccommunication system, using mobile phones and patient/physician portals to allow patient-specific treatment and communication. All physicians receive American Diabetes Association (ADA) Guidelines for diabetes care. Patients with poor diabetes control (A1c> or =7.5%) at baseline (n=260) are enrolled in study groups based on PCP randomization. All study patients receive blood glucose (BG) meters and a year's supply of testing materials. Patients in three treatment groups select one of two mobile phone models, receive one-year unlimited mobile phone data and service plan, register on the web-based individual patient portal and receive study treatment phone software based on study assignment. Control group patients receive usual care from their PCP. The primary outcome is mean change in A1c over a 12-month intervention period. Traditional methods of disease management have not achieved adequate control for BG and other conditions important to persons with diabetes. Tools to improve communication between patients and PCPs may improve patient outcomes and be satisfactory to patients and physicians. This RCT is ongoing.

  7. Association of blood eosinophils and plasma periostin with FEV1 response after 3-month inhaled corticosteroid and long-acting beta2-agonist treatment in stable COPD patients

    Directory of Open Access Journals (Sweden)

    Park HY

    2015-12-01

    with an improvement in forced expiratory volume in 1 second (FEV1 after 3-month treatment with ICS/long-acting beta2-agonist (LABA in stable COPD patients. Patients and methods: Blood eosinophils and plasma periostin levels were measured in 130 stable COPD subjects selected from the Korean Obstructive Lung Disease cohort. Subjects began a 3-month ICS/LABA treatment after washout period. Results: High blood eosinophils (>260/µL, adjusted odds ratio =3.52, P=0.009 and high plasma periostin (>23 ng/mL, adjusted odds ratio =3.52, P=0.013 were significantly associated with FEV1 responders (>12% and 200 mL increase in FEV1 from baseline after treatment. Moreover, the addition of high blood eosinophils to age, baseline positive bronchodilator response, and FEV1 <50% of the predicted value significantly increased the area under the curve for prediction of FEV1 responders (from 0.700 to 0.771; P=0.045. Conclusion: High blood eosinophils and high plasma periostin were associated with improved lung function after 3-month ICS/LABA treatment. In particular, high blood eosinophils, in combination with age and baseline lung function parameters, might be a possible biomarker for identification of COPD patients with favorable FEV1 improvement in response to ICS/LABA treatment. Keywords: eosinophils, periostin, COPD

  8. Internet-Based Contingency Management to Improve Adherence with Blood Glucose Testing Recommendations for Teens with Type 1 Diabetes

    Science.gov (United States)

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2…

  9. Cancer odor in the blood of ovarian cancer patients: a retrospective study of detection by dogs during treatment, 3 and 6 months afterward

    International Nuclear Information System (INIS)

    Horvath, György; Andersson, Håkan; Nemes, Szilárd

    2013-01-01

    In recent decades it has been noted that trained dogs can detect specific odor molecules emitted by cancer cells. We have shown that the same odor can also be detected in the patient’s blood with high sensitivity and specificity by trained dogs. In the present study, we examined how the ability of dogs to detect this smell was affected by treatment to reduce tumor burden, including surgery and five courses of chemotherapy. In Series I, one drop of plasma from each of 42 ovarian cancer patients (taken between the fifth and sixth courses of chemotherapy) and 210 samples from healthy controls were examined by two trained dogs. All 42 patients in Series I had clinical complete responses, all except two had normal CA-125 values and all were declared healthy after primary treatment. In Series II, the dogs examined blood taken from a new subset of 10 patients at 3 and 6 months after the last (sixth) course of chemotherapy. In Series I, the dogs showed high sensitivity (97%) and specificity (99%), for detecting viable cancer cells or molecular cancer markers in the patients’ plasma. Indeed, 29 of 42 patients died within 5 years. In Series II, the dogs indicated positive samples from three of the 10 patients at both the 3- and 6-month follow-up. All three patients had recurrences, and two died 3–4 years after the end of treatment. This was one of the most important findings of this study. Seven patients were still alive in January 2013. Although our study was based on a limited number of selected patients, it clearly suggests that canine detection gave us a very good assessment of the prognosis of the study patients. Being able to detect a marker based on the specific cancer odor in the blood would enhance primary diagnosis and enable earlier relapse diagnosis, consequently increasing survival

  10. Cancer odor in the blood of ovarian cancer patients: a retrospective study of detection by dogs during treatment, 3 and 6 months afterward.

    Science.gov (United States)

    Horvath, György; Andersson, Håkan; Nemes, Szilárd

    2013-08-26

    In recent decades it has been noted that trained dogs can detect specific odor molecules emitted by cancer cells. We have shown that the same odor can also be detected in the patient's blood with high sensitivity and specificity by trained dogs. In the present study, we examined how the ability of dogs to detect this smell was affected by treatment to reduce tumor burden, including surgery and five courses of chemotherapy. In Series I, one drop of plasma from each of 42 ovarian cancer patients (taken between the fifth and sixth courses of chemotherapy) and 210 samples from healthy controls were examined by two trained dogs. All 42 patients in Series I had clinical complete responses, all except two had normal CA-125 values and all were declared healthy after primary treatment. In Series II, the dogs examined blood taken from a new subset of 10 patients at 3 and 6 months after the last (sixth) course of chemotherapy. In Series I, the dogs showed high sensitivity (97%) and specificity (99%), for detecting viable cancer cells or molecular cancer markers in the patients' plasma. Indeed, 29 of 42 patients died within 5 years. In Series II, the dogs indicated positive samples from three of the 10 patients at both the 3- and 6-month follow-up. All three patients had recurrences, and two died 3-4 years after the end of treatment. This was one of the most important findings of this study. Seven patients were still alive in January 2013. Although our study was based on a limited number of selected patients, it clearly suggests that canine detection gave us a very good assessment of the prognosis of the study patients. Being able to detect a marker based on the specific cancer odor in the blood would enhance primary diagnosis and enable earlier relapse diagnosis, consequently increasing survival.

  11. Comparision between bed side testing of blood glucose by glucometer vs centralized testing in a tertiary care hospital.

    Science.gov (United States)

    Baig, Ayaz; Siddiqui, Imran; Jabbar, Abdul; Azam, Syed Iqbal; Sabir, Salman; Alam, Shahryar; Ghani, Farooq

    2007-01-01

    To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital. The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Department of Medicine, Aga Khan University and Hospital Karachi, from April 2005 to March 2006. One hundred and ten patients were included in the study. The blood glucose levels were analyzed on glucometer (Precision Abbott) by finger stick, using Biosensor Technology. At the same time venous blood was obtained to analyze glucose in clinical laboratory on automated analyzer (SYNCHRON CX7) by glucose oxidase method. We observed good correlation between bed side glucometer and laboratory automated analyzer for glucose values between 3.3 mmol/L (60 mg/dl) and 16.7 (300 mg/dl). A significant difference was observed for glucose values less than 3.3 mmol/L (p = 0.002) and glucose values more than 16.67 mmol/l (p = 0.049). Mean Turnaround time for glucometer and automated analyzer were 0.08 hours and 2.49 hours respectively. The cost of glucose testing with glucometer was 48.8% lower than centralized lab based testing. Bedside glucometer testing, though less expensive does not have good accuracy in acutely ill patient with either very high or very low blood glucose levels.

  12. Disparities in the receipt of fecal occult blood test versus endoscopy among Filipino American immigrants.

    Science.gov (United States)

    Maxwell, Annette E; Danao, Leda L; Crespi, Catherine M; Antonio, Cynthia; Garcia, Gabriel M; Bastani, Roshan

    2008-08-01

    This report examines disparities associated with the type of colorectal screening test, fecal occult blood test versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Between July 2005 and October 2006, Filipino Americans aged 50 to 75 years from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer screening. Among the 230 subjects who had ever received a routine screening test, 78 had fecal occult blood test only (16% of the total sample), and 152 had endoscopy with or without fecal occult blood test (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had fecal occult blood test only versus those who had endoscopy: acculturation, assessed by percent lifetime in the United States and language of interview, and income. Our data suggest a two-tier system, fecal occult blood test for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted.

  13. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.

    Science.gov (United States)

    Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho

    2016-10-26

    To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was

  14. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek

    2014-01-01

    BACKGROUND & AIMS: Dietary chloroplast thylakoids have previously been found to reduce food intake and body weight in animal models, and to change metabolic profiles in humans in mixed-food meal studies. The aim of this study was to investigate the modulatory effects of thylakoids on glucose...... metabolism and appetite-regulating hormones during an oral glucose tolerance test in pigs fed a high fat diet. METHODS: Six pigs were fed a high fat diet (36 energy% fat) for one month before oral glucose tolerance test (1 g/kg d-glucose) was performed. The experiment was designed as a cross-over study......, either with or without addition of 0.5 g/kg body weight of thylakoid powder. RESULTS: The supplementation of thylakoids to the oral glucose tolerance test resulted in decreased blood glucose concentrations during the first hour, increased plasma cholecystokinin concentrations during the first two hours...

  15. Typhidot M and Diazo test vis-à-vis blood culture and Widal test in the early diagnosis of typhoid fever in children in a resource poor setting.

    Science.gov (United States)

    Beig, Farzana K; Ahmad, Faraz; Ekram, Mohd; Shukla, Indu

    2010-01-01

    Typhoid fever is a major public health problem. A test which is simple, reliable and can be carried out in small laboratories is the need of the hour. We prospectively evaluated typhidot M and Diazo tests vis-à-vis blood culture and Widal test in children. Patients aged 6 months to 12 years, having fever of more than four days duration with clinical suspicion of typhoid fever were enrolled. Patients in whom other diagnosis was made served as control. The tests under scrutiny were validated against blood culture and then all the four tests were evaluated among patients who presented in the first week of illness. Blood culture was positive in only 27.3% of the cases. Among these culture positive cases, typhidot M test had the highest sensitivity, specificity, PPV and NPV of 90% (95% CI = 74.4-96.5), 100% (95% CI = 90.1-100), 100% (95% CI = 87.5-100), and 92.1% (95% CI = 79.2-97.3) respectively. Diazo test ranked next with sensitivity, specificity, PPV and NPV of 86.7% (95% CI = 70.3-94.7), 85.7% (95% CI = 70.6-93.7), 83.9% (95% CI = 67.4-92.9), 88.2% (95% CI = 73.4-95.3) respectively. Among clinically suspected typhoid cases, the overall sensitivity, of blood culture, Widal, typhidot M, Diazo was 27.3% (95% CI = 19.8- 36.3), 64.6% (95% CI = 55.3-72.9), 89.1% (95% CI = 81.9-93.7), 80.9% (95% CI = 72.6-87.2) respectively. In the first week of illness, typhidot M showed the best sensitivity [86.2% (95% CI = 69.4-94.5)] followed by Diazo [79% (95% CI = 61.6-90.2)], Widal [41.4% (95% CI = 25.5-59.3)] and blood culture [31% (95% CI = 17.3-49.2)]. Both Typhidot M and Diazo are good screening tests for the diagnosis of typhoid fever. Typhidot M is superior to Diazo but the latter is more suitable to resource poor settings being economic and easy to perform.

  16. Typhidot M and Diazo test vis-à-vis blood culture and Widal test in the early diagnosis of typhoid fever in children in a resource poor setting

    Directory of Open Access Journals (Sweden)

    Farzana K Beig

    Full Text Available OBJECTIVE: Typhoid fever is a major public health problem. A test which is simple, reliable and can be carried out in small laboratories is the need of the hour. We prospectively evaluated typhidot M and Diazo tests vis-à-vis blood culture and Widal test in children. METHODS: Patients aged 6 months to 12 years, having fever of more than four days duration with clinical suspicion of typhoid fever were enrolled. Patients in whom other diagnosis was made served as control. The tests under scrutiny were validated against blood culture and then all the four tests were evaluated among patients who presented in the first week of illness. RESULTS: Blood culture was positive in only 27.3% of the cases. Among these culture positive cases, typhidot M test had the highest sensitivity, specificity, PPV and NPV of 90% (95% CI = 74.4-96.5, 100% (95% CI = 90.1-100, 100% (95% CI = 87.5-100, and 92.1% (95% CI = 79.2-97.3 respectively. Diazo test ranked next with sensitivity, specificity, PPV and NPV of 86.7% (95% CI = 70.3-94.7, 85.7% (95% CI = 70.6-93.7, 83.9% (95% CI = 67.4-92.9, 88.2% (95% CI = 73.4-95.3 respectively. Among clinically suspected typhoid cases, the overall sensitivity, of blood culture, Widal, typhidot M, Diazo was 27.3% (95% CI = 19.8- 36.3, 64.6% (95% CI = 55.3-72.9, 89.1% (95% CI = 81.9-93.7, 80.9% (95% CI = 72.6-87.2 respectively. In the first week of illness, typhidot M showed the best sensitivity [86.2% (95% CI = 69.4-94.5] followed by Diazo [79% (95% CI = 61.6-90.2], Widal [41.4% (95% CI = 25.5-59.3] and blood culture [31% (95% CI = 17.3-49.2]. CONCLUSION: Both Typhidot M and Diazo are good screening tests for the diagnosis of typhoid fever. Typhidot M is superior to Diazo but the latter is more suitable to resource poor settings being economic and easy to perform.

  17. [Results of Training for Personnel Involved in Blood-Transfusion Testing Outside of Regular Work Hours at Saga University Hospital].

    Science.gov (United States)

    Yamada, Marie; Yamada, Naotomo; Higashitani, Takanori; Ohta, Shoichiro; Sueoka, Eisaburo

    2015-11-01

    Laboratory testing prior to blood transfusion outside of regular hours in many hospitals and clinics is frequently conducted by technicians without sufficient experience in such testing work. To obtain consistent test results regardless of the degree of laboratory experience with blood transfusion testing, the number of facilities introducing automated equipment for testing prior to blood transfusion is increasing. Our hospital's blood transfusion department introduced fully automated test equipment in October of 2010 for use when blood transfusions are conducted outside of regular hours. However, excessive dependence on automated testing can lead to an inability to do manual blood typing or cross-match testing when necessitated by breakdowns in the automated test equipment, in the case of abnormal specimen reactions, or other such case. In addition, even outside of normal working hours there are more than a few instances in which transfusion must take place based on urgent communications from clinical staff, with the need for prompt and flexible timing of blood transfusion test and delivery of blood products. To address this situation, in 2010 we began training after-hours laboratory personnel in blood transfusion testing to provide practice using test tubes manually and to achieve greater understanding of blood transfusion test work (especially in cases of critical blood loss). Results of the training and difficulties in its implementation for such after-hours laboratory personnel at our hospital are presented and discussed in this paper. [Original

  18. A Rapid Blood Test To Determine the Active Status and Duration of Acute Viral Infection.

    Science.gov (United States)

    Zheng, Tianyu; Finn, Caroline; Parrett, Christopher J; Dhume, Kunal; Hwang, Ji Hae; Sidhom, David; Strutt, Tara M; Li Sip, Yuen Yee; McKinstry, Karl K; Huo, Qun

    2017-11-10

    The ability to rapidly detect and diagnose acute viral infections is crucial for infectious disease control and management. Serology testing for the presence of virus-elicited antibodies in blood is one of the methods used commonly for clinical diagnosis of viral infections. However, standard serology-based tests have a significant limitation: they cannot easily distinguish active from past, historical infections. As a result, it is difficult to determine whether a patient is currently infected with a virus or not, and on an optimal course of action, based off of positive serology testing responses. Here, we report a nanoparticle-enabled blood test that can help overcome this major challenge. The new test is based on the analysis of virus-elicited immunoglobulin G (IgG) antibody present in the protein corona of a gold nanoparticle surface upon mixing the gold nanoparticles with blood sera. Studies conducted on mouse models of influenza A virus infection show that the test gives positive responses only in the presence of a recent acute viral infection, approximately between day 14 and day 21 following the infection, and becomes negative thereafter. When used together with the traditional serology testing, the nanoparticle test can determine clearly whether a positive serology response is due to a recent or historical viral infection. This new blood test can provide critical clinical information needed to optimize further treatment and/or to determine if further quarantining should be continued.

  19. Estimation of Genetic Parameters for First Lactation Monthly Test-day Milk Yields using Random Regression Test Day Model in Karan Fries Cattle

    Directory of Open Access Journals (Sweden)

    Ajay Singh

    2016-06-01

    Full Text Available A single trait linear mixed random regression test-day model was applied for the first time for analyzing the first lactation monthly test-day milk yield records in Karan Fries cattle. The test-day milk yield data was modeled using a random regression model (RRM considering different order of Legendre polynomial for the additive genetic effect (4th order and the permanent environmental effect (5th order. Data pertaining to 1,583 lactation records spread over a period of 30 years were recorded and analyzed in the study. The variance component, heritability and genetic correlations among test-day milk yields were estimated using RRM. RRM heritability estimates of test-day milk yield varied from 0.11 to 0.22 in different test-day records. The estimates of genetic correlations between different test-day milk yields ranged 0.01 (test-day 1 [TD-1] and TD-11 to 0.99 (TD-4 and TD-5. The magnitudes of genetic correlations between test-day milk yields decreased as the interval between test-days increased and adjacent test-day had higher correlations. Additive genetic and permanent environment variances were higher for test-day milk yields at both ends of lactation. The residual variance was observed to be lower than the permanent environment variance for all the test-day milk yields.

  20. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  1. Why testes are resistant to hydatidosis: Is blood-testis-barrier ...

    African Journals Online (AJOL)

    There was demonstrable hydatid cyst (protoscoleces and germinative layer) in testes of five rabbits from Group A, but in one rabbit, both testes were normal. In Group B, three out of four rabbits developed peritoneal hydatidosis. The mechanism of testicular resistance to echinococcosis could be due to blood-testis barrier ...

  2. A test of cognitive mediation in a 12-month physical activity workplace intervention: does it explain behaviour change in women?

    Science.gov (United States)

    Plotnikoff, Ronald C; Pickering, Michael A; Rhodes, Ryan E; Courneya, Kerry S; Spence, John C

    2010-05-03

    Attempts to demonstrate the efficacy of interventions aimed at increasing physical activity (PA) have been mixed. Further, studies are seldom designed in a manner that facilitates the understanding of how or why a treatment is effective or ineffective and PA intervention designs should be guided by a heavier reliance upon behavioral theory. The use of a mediating variable framework offers a systematic methodological approach to testing the role of theory, and could also identify the effectiveness of specific intervention components. The primary purpose of this paper was to test the mediating role that cognitive constructs may have played in regards to the positive effect that a workplace behavioral intervention had on leisure-time PA for women. A subsidiary purpose was to examine the cross-sectional relationships of these cognitive constructs with PA behavior. The Physical Activity Workplace Study was a randomized controlled trial which compared the effects of stage-matched and standard print materials upon self-reported leisure-time PA, within a workplace sample at 6 and 12-months. In this secondary analysis we examined the mediation effects of 14 psychosocial constructs across 3 major social-cognitive theories which were operationalized for the intervention materials and measured at baseline, 6 and 12-months. We examined change in PA and change in the psychological constructs employing a mediation strategy proposed by Baron and Kenny for: (1) the first 6-months (i.e., initial change), (2) the second 6-months (i.e., delayed change), and (3) the entire 12-months (overall change) of the study on 323 women (n = 213 control/standard materials group; n = 110 stage-matched materials group). Of the 14 constructs and 42 tests (including initial, delayed and overall change) two positive results were identified (i.e., overall change in pros, initial change in experiential powerful intervention approaches processes), with very small effect sizes. However, these mediating

  3. A test of cognitive mediation in a 12-month physical activity workplace intervention: does it explain behaviour change in women?

    Directory of Open Access Journals (Sweden)

    Pickering Michael A

    2010-05-01

    Full Text Available Abstract Background Attempts to demonstrate the efficacy of interventions aimed at increasing physical activity (PA have been mixed. Further, studies are seldom designed in a manner that facilitates the understanding of how or why a treatment is effective or ineffective and PA intervention designs should be guided by a heavier reliance upon behavioral theory. The use of a mediating variable framework offers a systematic methodological approach to testing the role of theory, and could also identify the effectiveness of specific intervention components. The primary purpose of this paper was to test the mediating role that cognitive constructs may have played in regards to the positive effect that a workplace behavioral intervention had on leisure-time PA for women. A subsidiary purpose was to examine the cross-sectional relationships of these cognitive constructs with PA behavior. Methods The Physical Activity Workplace Study was a randomized controlled trial which compared the effects of stage-matched and standard print materials upon self-reported leisure-time PA, within a workplace sample at 6 and 12-months. In this secondary analysis we examined the mediation effects of 14 psychosocial constructs across 3 major social-cognitive theories which were operationalized for the intervention materials and measured at baseline, 6 and 12-months. We examined change in PA and change in the psychological constructs employing a mediation strategy proposed by Baron and Kenny for: (1 the first 6-months (i.e., initial change, (2 the second 6-months (i.e., delayed change, and (3 the entire 12-months (overall change of the study on 323 women (n = 213 control/standard materials group; n = 110 stage-matched materials group. Results Of the 14 constructs and 42 tests (including initial, delayed and overall change two positive results were identified (i.e., overall change in pros, initial change in experiential powerful intervention approaches processes, with very

  4. Blood

    Science.gov (United States)

    ... a reduced production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  5. The relationship between blood potassium, blood lactate, and electromyography signals related to fatigue in a progressive cycling exercise test.

    Science.gov (United States)

    Tenan, Matthew S; McMurray, Robert G; Blackburn, B Troy; McGrath, Melanie; Leppert, Kyle

    2011-02-01

    Local muscle fatigue may be related to potassium efflux from the muscle cell and/or lactate accumulation within the muscle. Local fatigue causes a decrease in median frequency (MPF) of the electromyogram's power spectrum during isometric contractions but its relationship to changes in potassium and lactate during dynamic exercise is equivocal. Thus, this investigation evaluated relationships between changes in the MPF from the vastus lateralis and blood levels of lactate and potassium during an incremental cycling test and recovery. Trained cyclists (n=8) completed a discontinuous, graded cycle test to exhaustion under normal and glycogen-reduced conditions. The glycogen reduced condition promoted an environment of lower lactate production while permitting a consistent potassium response. Blood samples and maximal isometric EMG data were collected at the end of each stage and during recovery. Maximal lactate levels were ∼ 60% lower in the glycogen reduced condition; potassium was similar between trials. MPF did not change significantly at volitional fatigue. Further, MPF was not significantly related to lactate (p>0.27) or potassium (p>0.16) in either condition. Though both lactate and potassium have been implicated as factors relating to local muscle fatigue, neither is significantly related to changes in MPF during or after progressive exercise on a cycle ergometer. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Elevated admission microalbuminuria predicts poor myocardial blood flow and 6-month mortality in ST-segment elevation myocardial infarction patients undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Chen, Jia Wei; Wang, Yong Liang; Li, Hong Wei

    2012-04-01

    Microalbuminuria (MA) is considered a major risk factor predisposing to cardiovascular morbidity and mortality. Outcomes after percutaneous coronary intervention (PCI) for patients with acute myocardial infarction (AMI) complicated by MA have been well described. However, data regarding admission MA and coronary and myocardial flow are scant. The aims of this study were to evaluate the effects of admission MA on coronary blood flow and prognosis in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary PCI. Did elevated admission microalbuminuria predict poor myocardial blood flow and 6-month mortality in ST-segment elevation myocardial infarction patients undergoing primary percutaneous coronary intervention? A total of 247 patients undergoing primary PCI for STEMI within 12 hours after symptom onset were studied. Patients were divided into 2 groups according to admission urinary albumin extraction rate (UAER): (1) an MA group (UAER 20-200 µg/min), and (2) a normoalbuminuria (NA) group (UAER < 20 µg/min). Microalbuminuria was observed in 108 patients. Univariate analyses showed statistical differences between the NA and MA groups in serum creatine level, plasma glucose level, and peak creatine kinase level on presentation. Thrombolysis In Myocardial Infarction (TIMI) flow grades (TFGs) 0-2 in the MA group were more frequent (9.4% vs 21.2%, P < 0.05) than in the NA group, and corrected TIMI frame count was higher (23.9 ± 18.5 vs 29.8 ± 23.5, P < 0.05). Admission MA was an independent predictor of poor myocardial perfusion (adjusted relative risk: 3.14, 95% confidence interval: 0.99-6.78) and a higher rate of 6-month mortality in STEMI patients undergoing primary PCI (adjusted relative risk: 1.58, 95% confidence interval: 0.74-3.39). Admission MA levels are associated with impaired myocardial flow and poor prognosis in STEMI patients undergoing primary PCI. © 2012 Wiley Periodicals, Inc.

  7. No harmful effect of different Coca-cola beverages after 6 months of intake on rat testes.

    Science.gov (United States)

    Tóthová, Lubomíra; Hodosy, Július; Mettenburg, Kathryn; Fábryová, Helena; Wagnerová, Alexandra; Bábíčková, Janka; Okuliarová, Monika; Zeman, Michal; Celec, Peter

    2013-12-01

    Our laboratory recently reported that a 3-month exposure of rats to cola-like beverages induced sex hormone changes. The aim of the study was to investigate the effects of various types of Coca-cola intake with different composition for 6 months on oxidative status in testes and testosterone in adult male rats. Fifty adult male Wistar rats were divided into control group drinking water, and groups drinking different Coca-cola beverages (regular Coca-cola, Coca-cola caffeine-free, Coca-cola Light and Coca-cola Zero). Oxidative and carbonyl stress markers were measured in the testicular tissue to assess oxidative status together with testicular and plasma testosterone. StAR expression in testes as a marker of steroidogenesis was quantified. No significant differences were found between the groups in any of the measured parameters. In conclusion, oxidative and carbonyl stress in testicular tissue were not influenced by drinking any type of Coca-cola. Additionally, testosterone in testes and in plasma, as well as testicular StAR expression were comparable among the groups. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  9. Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.

    Science.gov (United States)

    Someya, Takeshi; Kobayashi, Mariko; Waguri, Satoshi; Ushiyama, Tomohiro; Nagaoka, Eiki; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2009-09-01

    MedTech Dispo, a disposable maglev centrifugal blood pump with two degrees of freedom magnetic suspension and radial magnetic coupling rotation, has been developed for 1-month extracorporeal circulatory support. As the first stage of a two-stage in vivo evaluation, 2-week evaluation of a prototype MedTech Dispo was conducted. In in vitro study, the pump could produce 5 L/min against 800 mm Hg and the normalized index of hemolysis was 0.0054 +/- 0.0008 g/100 L. In in vivo study, the pump, with its blood-contacting surface coated with biocompatible 2-methacryloyloxyethyl phosphorylcholine polymer, was implanted in seven calves in left heart bypass. Pump performance was stable with a mean flow of 4.49 +/- 0.38 L/min at a mean speed of 2072.1 +/- 64.5 rpm. The maglev control revealed its stability in rotor position during normal activity by the calves. During 2 weeks of operation in two calves which survived the intended study period, no thrombus formation was seen inside the pump and levels of plasma free hemoglobin were maintained below 4 mg/dL. Although further experiments are required, the pump demonstrated the potential for sufficient and reliable performance and biocompatibility in meeting the requirements for cardiopulmonary bypass and 1-week circulatory support.

  10. Routine blood tests are associated with short term mortality and can improve emergency department triage

    DEFF Research Database (Denmark)

    Kristensen, Michael; Iversen, Anne Kristine Servais; Gerds, Thomas Alexander

    2017-01-01

    BACKGROUND: Prioritization of acutely ill patients in the Emergency Department remains a challenge. We aimed to evaluate whether routine blood tests can predict mortality in unselected patients in an emergency department and to compare risk prediction with a formalized triage algorithm. METHODS...... registration. Multiple logistic regressions were used to predict 30-day mortality. Validation was performed by applying the regression models on the 2013 validation cohort. RESULTS: Thirty-day mortality was 5.3%. The routine blood tests had a significantly stronger discriminative value on 30-day mortality...... compared to the formalized triage (AUC 88.1 [85.7;90.5] vs. 63.4 [59.1;67.5], p blood tests was able to identify a larger number of low risk patients (n = 2100, 30-day mortality 0.1% [95% CI 0.0;0.3%]) compared to formalized triage (n = 1591, 2.8% [95% CI 2...

  11. Red cell antigen prevalence predicted by molecular testing in ethnic groups of South Texas blood donors.

    Science.gov (United States)

    Aranda, Lorena I; Smith, Linda A; Jones, Scott; Beddard, Rachel

    2015-01-01

    Alloimmunization to red blood cell antigens is seen in patients receiving chronic blood transfusion. Knowing the prevalence of blood group antigens of the different ethnicities of South Texas donors can provide better management of rare blood inventory for patients in this geographical area. A total of 4369 blood donors were tested and analyzed for various antigens in the following blood group systems: ABO, Rh, Kell, Duffy, Kidd, MNS, Lutheran, Dombrock, Landsteiner-Wiener, Diego, Colton, and Scianna. Donors tested to be group 0 or A were serologically tested for the Rh (C, E, c, e) antigens. Those that tested as presumably R1R1, R2R2, or Ror were then genotyped. Donors constituted three major ethnicities: black (18.3%), Hispanic (36.3%), and Caucasian (41.1%); ethnicities comprised of Asian, American Indian, multiracial, and other accounted for the remaining donors (4.3%). The most likely common Rh phenotype for each ethnicity is as follows: black -Ror (44.4%), Hispanic -R1R1 (59.0%), and Caucasian -R1R1 (38.9%). The prevalence of Kell, Duffy, and Kidd blood group system antigens in black and Caucasian donors is comparable with published reports for the entire U.S. The black South Texas donor population had an 8.8 percent increase in prevalence of the Fy(a+b-) phenotype as compared with these published reports; the Hispanic South Texas donor population had a prevalence of 36.1 percent of the Fy(a+b-) phenotype. Regarding the Diego blood group system, the Hispanic donor population in South Texas had a prevalence of 93.5 percent for the Di(a-b+) phenotype as compared with published reports for the entire U.S. (>99.9%). The Hispanic population had a prevalence of 7.9 percent of donors testing as M-N+S-s+ as compared with 20.2 percent and 15.6 percent for black and Caucasian donors, respectively. This study helped us determine the prevalence of each of the blood group antigens in the South Texas donor population to establish and maintain adequate rare inventory of

  12. Diagnosis of different liver fibrosis characteristics by blood tests in non-alcoholic fatty liver disease.

    Science.gov (United States)

    Calès, Paul; Boursier, Jérôme; Chaigneau, Julien; Lainé, Fabrice; Sandrini, Jeremy; Michalak, Sophie; Hubert, Isabelle; Dib, Nina; Oberti, Frédéric; Bertrais, Sandrine; Hunault, Gilles; Cavaro-Ménard, Christine; Gallois, Yves; Deugnier, Yves; Rousselet, Marie C

    2010-10-01

    Our aim was to develop an accurate, non-invasive, blood-test-based method for identifying the main characteristics of liver fibrosis in non-alcoholic fatty liver disease (NAFLD). Fibrosis was staged according to NASH-CRN and Metavir systems in 226 patients with NAFLD. A fully automated algorithm measured the fractal dimension (FD) and the area of fibrosis (AOF). Independent predictors of diagnostic targets were determined using bootstrap methods. (i) Development. Significant fibrosis defined by NASH-CRN F ≥2 was diagnosed by weight, glycaemia, aspartate aminotransferase (AST), alanine aminotransferase (ALT) and prothrombin index [area under the receiver operating characteristic (AUROC)=0.867]; significant fibrosis defined by Metavir F ≥2 was diagnosed by weight, age, glycaemia, AST, ALT, ferritin and platelets (FibroMeter AUROC=0.941, Pfibrosis staging, Metavir staging was a better reference for blood test. Thus, the patient rate with predictive values ≥90% by tests was 97.3% with Metavir reference vs. 66.5% with NASH-CRN reference (Pfibrosis score for significant fibrosis, but not for severe fibrosis or cirrhosis, with both staging systems. Relationships between fibrosis lesions were well reflected by blood tests, e.g., the correlation between histological area and FD of fibrosis (r(s) =0.971, Pblood tests (r(s) =0.852, Pfibrosis in NAFLD can be diagnosed and quantified by blood tests with excellent accuracy. © 2010 John Wiley & Sons A/S.

  13. The colour of blood in skin: a comparison of Allen's test and photonics simulations.

    Science.gov (United States)

    Välisuo, Petri; Kaartinen, Ilkka; Kuokkanen, Hannu; Alander, Jarmo

    2010-11-01

    The colour of the skin reflects many physiological and pathological states of an individual. Usually, the skin colour is examined by the bare eye alone. Several scaling systems have been developed to quantify the sensory evaluation of skin colour. In this work, the reflectance of the skin is measured directly using an objective instrument. Haemoglobin inside the dermal circulation is one of the key factors of skin colour and it also has a major role in the appearance of many skin lesions and scars. To quantitatively measure and analyse such conditions, the relation between the skin colour and the haemoglobin concentration in the skin needs to be resolved. To examine the effect of blood concentration on the skin colour, five Allen's tests were performed on 20 persons. The skin colour change was measured using a spectrophotometer by changing the blood concentration by the Allen's test. Light interaction with the skin was simulated with a Monte Carlo model, tuning the blood concentration parameter until the simulated and the measured spectra matched, yielding the relationship between the skin colour and the blood concentration. The simulation produced spectra similar to those measured. The change in the blood concentration in the simulation model and in the skin produced changes similar to the spectra. The reflectance of the skin was found to be a nonlinear function of the blood concentration. The relationship found between skin colour and blood concentration makes it possible to quantify those skin conditions expressed by blood volume better than plain colour. © 2010 John Wiley & Sons A/S.

  14. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  15. Nucleic acid amplification testing in Indian blood banks: A review with perspectives

    Directory of Open Access Journals (Sweden)

    Kanjaksha Ghosh

    2017-01-01

    Full Text Available Background: Nucleic acid amplification testing (NAT is restricted to a few blood banks in India since 2008. This review was directed toward understanding NAT yield in different parts of the country and prevalence in the NAT of different types of virus. Materials and Methods: English literature was searched from 1990 to 2016 in PubMed, Scopus, Ind med, and Google database using properly constructed key words. Literature was collected and finally the data were synthesized. Results: NAT results from 11 publications and one personal communication showed that till date 389387 blood units have been NAT tested from various parts of the country. NAT yield varied from 1:476 to 1:4403 in various studies. Till date, 58/2550 (2% blood banks of India are doing NAT testing but all of them have not published their results. Majority of the centers have used ID-NAT (Individual NAT protocol and 21 blood banks are using minipool format of the test. One center has used in-house NAT testing system. In> 70% of the time, the NAT positivity with due to hepatitis B (Hep B. For individual infection, NAT yield from the pooled data showed HIV in 1:66,000, Hep C virus 1:5484 and Hep B in 1:1761 seronegative donors. Discussion and Conclusion: In view of the very high NAT yield (1:1361, NAT in some from needs to be universally applied in Indian blood banks. However, the high Hep B occult infection suggests stricter donor selection and immunization of adults for Hep B may be way forward toward ensuring the viral safety of blood components in India.

  16. Blood tests and prognosis in bladder carcinomas treated with definitive radiotherapy

    International Nuclear Information System (INIS)

    Hannisdal, E.; Fossa, S.D.; Host, H.

    1993-01-01

    The value of some commonly recorded blood tests as prognostic factors in patients with bladder carcinomas treated with definitive radiotherapy has been assessed. This study included 202 consecutive patients (T2, n=46; T3, n=82 and T4, n=74) treated during the period 1980-1987. The median total dose received was 56 Gy [50-67] and the median cumulative radiation effect was 1750 reu (radiation effect unit) (1515-1823). The blood tests examined in survival analyses were erythrocyte sedimentation rate (ESR), hemoglobin (Hb), leucocyte and thrombocyte count, alkaline phosphatase (ALP), γ-glutamyltransferase (GT), lactate dehydrogenase (LD), creatinine and albumin. In the univariate survival analyses six blood tests were significant prognostic factors (ESR, albumin, creatinine, Hb, ALP and GT). In the multivariate analysis of all 202 patients, the following five variables were significantly associated with shorter survival: T4 tumors, ESR > 30 mm/h, albumin 400 U/I and age >75 years. Our conclusion is that several commonly recorded blood tests are powerful prognostic factors in bladder cancer treated with definitive radiotherapy. These tests can replace other more expensive laboratory investigations used for prognostication. (author). figs. tabs

  17. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks

    Directory of Open Access Journals (Sweden)

    Otani Marcia M.

    2003-01-01

    Full Text Available OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV concomitantly using two different enzyme immunoassay (EIA tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo, which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4% had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58% did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great

  18. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  19. Six-year pilot study on nucleic acid testing for blood donations in China.

    Science.gov (United States)

    Ye, Xianlin; Yang, Baocheng; Zhu, Weigang; Zheng, Xin; Du, Peng; Zeng, Jingfeng; Li, Chengyao

    2013-10-01

    A six-year pilot study on nucleic acid testing for HBV, HCV and HIV-1 has been undertaken on sero-negative plasmas in mini-pool and individual donation testing at Shenzhen Blood Center. Of 307,740 sero-negative blood samples, 95 of 102 HBV DNA yields were confirmed positive, 80/95 (84.2%) were classified as occult HBV infection (OBI) and 15 (15.8%) as window period cases. Amongst OBIs, 45% carried anti-HBc only, 41.3% anti-HBc and anti-HBs and 13.7% anti-HBs only. HBV DNA yield was 1:3239. One HCV WP and one HIV-1 infected donations were detected. High residual risk was found in current blood donations screening in China. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Overuse of preoperative laboratory coagulation testing and ABO blood typing: a French national study.

    Science.gov (United States)

    Beloeil, H; Ruchard, D; Drewniak, N; Molliex, S

    2017-12-01

    Following publication of guidelines on routine preoperative tests, the French Society of Anaesthesiology and Intensive Care (SFAR), in association with French national public health insurance, conducted a survey to evaluate adherence to guidelines and the economic consequences. Using the French Hospital Discharge Database and National Health Insurance Information system, tests performed during the 30 days before surgery were analysed for two situations: (1) standard laboratory coagulation tests and ABO blood typing in children able to walk and scheduled for tonsillectomy/adenoidectomy; and (2) ABO blood typing in adults before laparoscopic cholecystectomy, thyroidectomy, lumbar discectomy or breast surgery. Guidelines do not recommend any preoperative tests in these settings. Between 2013 and 2015, a coagulation test was performed in 49% of the 241 017 children who underwent tonsillectomy and 39% of the 133 790 children who underwent adenoidectomy. A similar pattern was observed for ABO blood typing although re-operation rates for bleeding on the first postoperative day were very low (0.12-0.31% for tonsillectomy and 0.01-0.02% for adenoidectomy). Between 2012 and 2015, ABO blood typing was performed in 32-45% of the 1 114 082 patients who underwent one of the four selected procedures. The transfusion rate was very low (0.02-0.31%). The mean cost for the four procedures over the 4 yr period was €5 310 000 (sd €325 000). Standard laboratory coagulation tests and ABO blood typing are still routinely prescribed before surgery and anaesthesia despite current guidelines. This over-prescription represents a high and unnecessary cost, and should therefore be addressed. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  1. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  2. Algorithm of Transvaginal Ultrasound and/or Hysterosalpingogram for Confirmation Testing at 3 Months after Essure Placement.

    Science.gov (United States)

    Vleugels, Michel; Cheng, Ru-Fong; Goldstein, Jeffrey; Bangerter, Keith; Connor, Viviane

    To evaluate the algorithm of transvaginal ultrasound (TVU) and/or modified hysterosalpingogram (HSG) confirmation testing 3 months after Essure placement to determine if women can rely on the device for permanent birth control. Interim analysis of an ongoing 10-year, prospective, multicenter, nonrandomized, single-arm, international trial (Canadian Task Force classification II-2). Twenty study centers in the United States (n = 12), Canada (n = 1), The Netherlands (n = 6), and Spain (n = 1). Women undergoing the Essure procedure for permanent birth control. Based on the algorithm for confirmation testing, women with an uncomplicated Essure procedure underwent TVU as the confirmation test; modified HSG was used for women ineligible for TVU, when TVU findings were abnormal or inconclusive, or based on the physician's discretion. Co-primary endpoints (intention-to-treat [ITT] population) were the reliance rate and the 1-year pregnancy rate. Safety evaluation was based on adverse events. Bilateral insert placement was attempted in 597 women (ITT population) and achieved in 582 of 597 (97.5%). A total of 547 women were told to rely on Essure for permanent birth control. Both co-primary endpoints met prespecified limits: based on Bayesian statistics, the reliance rate was 91.6% (547/597; 95% credible interval, 89.2%-93.6%) and the 1-year pregnancy rate .67% (95% credible interval, .16%-1.53%). Using the algorithm for confirmation testing, of 547 subjects told to rely on Essure, 470 (86%) underwent TVU alone, 30 (6%) had modified HSG alone, and 47 (9%) had TVU followed by modified HSG. Four women became pregnant after being told to rely on Essure. They all had confirmation testing with TVU alone, and each initially read incorrectly as optimal insert locations. In each case postpregnancy follow-up and root cause analysis revealed unsatisfactory insert locations, 2 of which were perforations. Most adverse events were mild and unrelated to Essure. The

  3. Is D U Phenotype Testing A Necessity In Blood Bank Practice In ...

    African Journals Online (AJOL)

    Objective: To evaluate the necessity of Du Phenotype testing in blood bank practice in Nigeria. Design: Cross-sectional study. Setting: Three health institutions within Port Harcourt metropolis: The University of Port Harcourt Teaching Hospital, Braithewaite Memorial Hospital, Port Harcourt and Orogbum comprehensive ...

  4. Endoscopic Follow-Up of Positive Fecal Occult Blood Testing in the Ontario FOBT Project

    Directory of Open Access Journals (Sweden)

    Lawrence Paszat

    2007-01-01

    Full Text Available BACKGROUND: The Ontario FOBT Project is a pilot study of fecal occult blood testing (FOBT for colorectal cancer screening conducted among age-eligible volunteers (50 to 75 years in 12 of 37 public health regions in Ontario.

  5. Performance on Paced Auditory Serial Addition Test and cerebral blood flow in multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, M.; Steen, C.; Hoogduin, J. M.; van Osch, M. J. P.; Fierens, Y.; Cambron, M.; Koch, M. W.; De Keyser, J.

    BackgroundTo assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). MethodsNormal

  6. Earlier stages of colorectal cancer detected with immunochemical faecal occult blood tests

    NARCIS (Netherlands)

    van Rossum, L. G. M.; van Rijn, A. F.; van Munster, I. P.; Jansen, J. B. M. J.; Fockens, P.; Laheij, R. J. F.; Dekker, E.

    2009-01-01

    Background: The aim of colorectal cancer screening is to improve prognosis by the detection of early cancer and precursor stages. We compared the stage distribution of asymptomatic colorectal cancer patients detected by a positive immunochemical or guaiac-based faecal occult blood test (FOBT) with

  7. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  8. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Activated whole blood clotting time tests. 864.7140 Section 864.7140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864...

  9. Quantitative measurement of blood circulation in tests of rats using nuclear medical methods

    International Nuclear Information System (INIS)

    Ripke, R.

    1980-01-01

    The experiments show that is it is possible to quantitatively assess the blood circulation and, within limits, the germinative function of tests by measuring the impulses of an incorporated radionuclide (99-Tc-pertechnetate) using an uptake measuring instrument. This is a rapid and unbloody method to be adopted in human medicine. 'Acute tests' or pre-damaged tests can thus be exactly diagnosed. In the former case the circulation modification and in the latter the evaluation of the germinative function ability is of main interest. The most important measuring criterion is the 15-minute-uptake U; it represents the blood circulation in the tests measured. The germinative function ability is evaluated on the basis of the accumulation activity Nsub(max). (orig./MG) [de

  10. In Vivo Model to Test Implanted Biosensors for Blood pH

    Science.gov (United States)

    Arnaud, Sara B.; Somps, Chris J.; Madou, Marc; Hines, John; Wade, Charles E. (Technical Monitor)

    1997-01-01

    Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

  11. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process

    Science.gov (United States)

    Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter

    2016-01-01

    Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263

  12. Usefullness of routine use of fecal occult blood test in a hospital setting

    Directory of Open Access Journals (Sweden)

    Simona Ravnik

    2006-12-01

    Full Text Available Background: Fecal occult blood test, hematest, is a well excepted non-invasive method used for detecting different diseases of the gastrointestinal tract. It was proven in different randomized studies that usage of this simple method may facilitate further diagnostic and therapeutic treatment.Patients and methods: The retrospective analysis includes patients, which were admitted to the gastroenterological and endoscopy department of the General hospital Maribor in the last quarter of the year 2005. In all patients fecal occult blood test was performed.Results: We examined 200 patients, 104 women and 96 men, average age 63.9 years, SD±16.9, ranging from 21 to 97 years. Positive hematest was discovered in 76 patients (38 %. The source of hemorrhage from the upper digestive tract was confirmed in 37 patients (48.6 % of all positive tests and from the lower digestive tract in 34 patients (46 % of all positive tests. The most frequent causes of hemorrhage from the lower digestive tract were chronic inflammatory bowel disease (13.1 % of all positive tests, colorectal cancer (10.5 % and polyps (6.6 %. The source of hemorrhage was not located in five patients (6.6 % of all positive tests despite the accurate diagnostic procedure.Conclusions: By performing a fecal occult blood screening in non-symptomatic patients, we can make an essential step towards discovering different gastrointestinal diseases, even colorectal cancer in its early, limited form, when the effect of treatment is greatest.

  13. Towards bio monitoring of toxic (lead) and essential elements in whole blood from 1- to 72-month old children: a cross-sectional study.

    Science.gov (United States)

    Kang-Sheng, Liu; Xiao-Dong, Mao; Juan, Shi; Chun-Fan, Dai; Pingqing, Gu

    2015-06-01

    Minerals such as zinc, copper, selenium, calcium, and magnesium are essential for normal human development and functioning of the body. They have been found to play important roles in immuno-physiologic functions. The study is to evaluate the distribution and correlation of nonessential (lead) and essential elements in whole blood from 1- to 72-month old children. The cross-sectional study was performed in 1551 children. Six element concentrations, including copper (Cu), zinc (Zn), calcium (Ca), magnesium (Mg), iron (Fe) and lead (Pb) in the blood were determined by atomic absorption spectrometry. Distributions and correlations of trace elements in different age groups were analyzed and compared. A Pearson correlation controlled for age and gender was used to assess the relationship of non essential (lead) and essential elements. Levels of copper and magnesium were 18.09 ± 4.42 µmol/L and 1.42 ± 0.12 mmol/L, respectively. 6.04% of all children showed copper levels below the normal threshold, the levels of Magnesium were stable in different age groups. Though the overall mean blood zinc and iron concentrations (61.19 ± 11.30 µmol/L and 8.24 ± 0.59 mmol/L, respectively) gradually increased with age and the overall deficiency levels (24.1% and 36.0%, respectively) decreased with age, zinc and iron deficiencies were still very stable. Controlling for gender and age, significant positive correlations were found when comparing copper to zinc, calcium, magnesium, and iron ((r = 0.333, 0.241, 0.417, 0.314 ,p lead levels (41.16 ± 16.10) were relatively unstable among different age groups. The prevalence of lead intoxication in all children was 1.3% .Calcium levels decreased gradually with age, with an overall concentration of 1.78 ± 0.13 mmol/L. Significant negative correlations were also noted between Pb and Zn, Fe (r = -0.179, -0.124.p lead intoxication in all the children studied was low; The established reference intervals for Cu, Zn, Ca and Mg provide an

  14. Inflammatory Stress on Autophagy in Peripheral Blood Mononuclear Cells from Patients with Alzheimer's Disease during 24 Months of Follow-Up.

    Directory of Open Access Journals (Sweden)

    Arnaud François

    Full Text Available Recent findings indicate that microglia in Alzheimer's disease (AD is senescent whereas peripheral blood mononuclear cells (PBMCs could infiltrate the brain to phagocyte amyloid deposits. However, the molecular mechanisms involved in the amyloid peptide clearance remain unknown. Autophagy is a physiological degradation of proteins and organelles and can be controlled by pro-inflammatory cytokines. The purpose of this study was to evaluate the impact of inflammation on autophagy in PBMCs from AD patients at baseline, 12 and 24 months of follow-up. Furthermore, PBMCs from healthy patients were also included and treated with 20 μM amyloid peptide 1-42 to mimic AD environment. For each patient, PBMCs were stimulated with the mitogenic factor, phytohaemagglutin (PHA, and treated with either 1 μM C16 as an anti-inflammatory drug or its vehicle. Autophagic markers (Beclin-1, p62/sequestosome 1 and microtubule-associated protein-light chain 3: LC3 were quantified by western blot and cytokines (Interleukin (IL-1β, Tumor necrosis Factor (TNF-α and IL-6 by Luminex X-MAP® technology. Beclin-1 and TNF-α levels were inversely correlated in AD PBMCs at 12 months post-inclusion. In addition, Beclin-1 and p62 increased in the low inflammatory environment induced by C16. Only LC3-I levels were inversely correlated with cognitive decline at baseline. For the first time, this study describes longitudinal changes in autophagic markers in PBMCs of AD patients under an inflammatory environment. Inflammation would induce autophagy in the PBMCs of AD patients while an anti-inflammatory environment could inhibit their autophagic response. However, this positive response could be altered in a highly aggressive environment.

  15. High blood levels of lead in children aged 6-36 months in Kathmandu Valley, Nepal: A cross-sectional study of associated factors

    Science.gov (United States)

    Karki, Khem Bahadur; Aryal, Krishna Kumar; Dhimal, Bimala; Joshi, Hari Datt; Puri, Sajan; Pandey, Achyut Raj; Dhakal, Purushotam; Sharma, Arun Kumar; Raya, Ganendra Bhakta; Ansari, Imran; Groneberg, David A.; Müller, Ruth; Kuch, Ulrich

    2017-01-01

    Young children are at greatest risk of exposure to lead and its effects. Although lead is one of the most widely used elements with known health hazard, there is little data on the blood lead level (BLL) of children in the Kathmandu Valley. Thus, this study aimed to assess factors associated with high BLL in children who were 6–36 months of age and resided in the Kathmandu Valley. In this hospital-based cross-sectional study 6–36 month-old children visiting the Paediatrics Outpatient Department of Tribhuvan University Teaching Hospital, Patan Hospital, and Siddhi Memorial Hospital were enrolled. All three hospitals are located in different areas inside the Kathmandu Valley. Written informed consent was obtained from the parents, and exposure data were collected using a structured questionnaire. Portable Anodic Stripping Voltammetry (ASV) was used to determine BLLs in children. Data were analyzed using SPSS version 16. Of 312 children enrolled in the study, 64.4% had BLLs ≥5μg/dl. A significant association was found between BLL and exposure to enamel paints in the household in the form of painting materials used in different parts of the house like walls, windows and doors (p = 0.001). Furthermore, multivariate analyses showed that BLLs were 4.5 times higher in children playing with dirt and dust (p = 0.006) and that children belonging to the community of lower caste/ethnicity groups had significantly higher BLLs compared to those from the upper caste groups (p = 0.02). Our study demonstrated that children living in households that have used enamel paints, children belonging to lower caste/ethnic groups, and children frequently playing with dirt and dust had significantly higher BLLs. The results of this study highlight the importance of policy decisions to limit environmental lead contamination, and to roll out awareness building measures designed to limit lead exposure and break the poverty cycle associated with chronic lead poisoning. PMID:28604801

  16. High blood levels of lead in children aged 6-36 months in Kathmandu Valley, Nepal: A cross-sectional study of associated factors.

    Directory of Open Access Journals (Sweden)

    Meghnath Dhimal

    Full Text Available Young children are at greatest risk of exposure to lead and its effects. Although lead is one of the most widely used elements with known health hazard, there is little data on the blood lead level (BLL of children in the Kathmandu Valley. Thus, this study aimed to assess factors associated with high BLL in children who were 6-36 months of age and resided in the Kathmandu Valley. In this hospital-based cross-sectional study 6-36 month-old children visiting the Paediatrics Outpatient Department of Tribhuvan University Teaching Hospital, Patan Hospital, and Siddhi Memorial Hospital were enrolled. All three hospitals are located in different areas inside the Kathmandu Valley. Written informed consent was obtained from the parents, and exposure data were collected using a structured questionnaire. Portable Anodic Stripping Voltammetry (ASV was used to determine BLLs in children. Data were analyzed using SPSS version 16. Of 312 children enrolled in the study, 64.4% had BLLs ≥5μg/dl. A significant association was found between BLL and exposure to enamel paints in the household in the form of painting materials used in different parts of the house like walls, windows and doors (p = 0.001. Furthermore, multivariate analyses showed that BLLs were 4.5 times higher in children playing with dirt and dust (p = 0.006 and that children belonging to the community of lower caste/ethnicity groups had significantly higher BLLs compared to those from the upper caste groups (p = 0.02. Our study demonstrated that children living in households that have used enamel paints, children belonging to lower caste/ethnic groups, and children frequently playing with dirt and dust had significantly higher BLLs. The results of this study highlight the importance of policy decisions to limit environmental lead contamination, and to roll out awareness building measures designed to limit lead exposure and break the poverty cycle associated with chronic lead poisoning.

  17. Preoperative hypoalgesia after cold pressor test and aerobic exercise is associated with pain relief six months after total knee replacement

    DEFF Research Database (Denmark)

    Vaegter, Henrik Bjarke; Handberg, Gitte; Emmeluth, Claus

    2017-01-01

    OBJECTIVES: Chronic pain after total knee replacement (TKR) is not uncommon. Preoperative impaired conditioning pain modulation (CPM) has been used to predict chronic postoperative pain. Interestingly, exercises reduce pain sensitivity in patients with knee osteoarthritis. This pilot study...... investigated the association between exercise-induced hypoalgesia (EIH) and CPM on post-TKR pain relief. METHODS: Before and six months post-TKR, 14 patients with chronic knee osteoarthritis performed the cold pressor test on the non-affected leg and two exercise conditions (bicycling and isometric knee...... at the affected leg improved post-TKR compared with pre-TKR (PCPM and bicycling EIH assessed by the increase in cPTT correlated with reduction in NRS pain scores post-TKR (PCPM and EIH responses after TKR were significantly correlated with reduction in NRS pain scores...

  18. CORD BLOOD NUCLEATED RED BLOOD CELL COUNT: A SIMPLE BEDSIDE TEST OF PERINATAL ASPHYXIA AND ITS CORRELATION WITH IMMEDIATE OUTCOME

    Directory of Open Access Journals (Sweden)

    Ramesh Chand

    2016-07-01

    Full Text Available BACKGROUND Asphyxia is a leading cause of foetal neonatal mortality and morbidity. Nucleated red blood cell count (NRBC produced as compensatory response to asphyxia in foetus and NRBC level can be correlated to asphyxia. Because the present indices are unhelpful in the diagnosis and prediction of the severity of asphyxia, we wished to investigate the relationship between the nucleated RBC count and the severity & immediate outcome of perinatal asphyxia. METHOD This prospective comparative study was conducted in maternity ward of Obstetrics & Gynaecology Department and Paediatric Department of GSVM Medical College, Kanpur (Central UP, from January 2014 to September 2014. Newborns of term gestation were selected after satisfying inclusion criteria and were divided in 2 groups. The control group consisted 60 normal newborns and case group had 60 asphyxiated newborns. The cord blood was collected soon after birth, investigated for pH and making smears that were stained with Leishman’s stain. NRBCs were counted against 100 WBCs. The statistical analysis was done using IMSTAT. RESULTS The mean NRBC count in the study group was 22.63±6.95 as compared to 4.75±2.04 in the control group (p=<0.0001. The NRBC count was significantly higher in low pH, neonates with low Apgar scores of < 3 at 1 minutes, newborns with HIE stage III & in neonates who were neurological abnormal at discharge (P=0.0001. CONCLUSIONS A simple, easy to do, cost effective bedside test, such as NRBC count at time of delivery is a good marker of perinatal asphyxia & its forthcoming immediate neurological outcome.

  19. Comparison of blood tests for liver fibrosis specific or not to NAFLD.

    Science.gov (United States)

    Calès, Paul; Lainé, Fabrice; Boursier, Jérôme; Deugnier, Yves; Moal, Valérie; Oberti, Frédéric; Hunault, Gilles; Rousselet, Marie Christine; Hubert, Isabelle; Laafi, Jihane; Ducluzeaux, Pierre Henri; Lunel, Françoise

    2009-01-01

    To compare blood tests of liver fibrosis specific for NAFLD: the FibroMeter NAFLD and the NAFLD fibrosis score (NFSA) with a non-specific test, APRI. Two hundred and thirty-five NAFLD patients with liver Metavir staging and blood markers from two independent centres were randomly assigned to a test (n=121) or a validation population (n=114). The highest accuracy--91%--for significant fibrosis was obtained with the FibroMeter whose (i) AUROC (0.943) was significantly higher than those of NFSA (0.884, p=0.008) and APRI (0.866, pliver biopsy could have been avoided in most patients: FibroMeter: 97.4% vs NFSA: 86.8% (pfibrosis, significantly outperforming NFSA and APRI.

  20. The effects of a 6-month resistance training and dried plum consumption intervention on strength, body composition, blood markers of bone turnover, and inflammation in breast cancer survivors.

    Science.gov (United States)

    Simonavice, Emily; Liu, Pei-Yang; Ilich, Jasminka Z; Kim, Jeong-Su; Arjmandi, Bahram; Panton, Lynn B

    2014-06-01

    The purpose of this study was to examine the effects of resistance training (RT) and dried plum (DP) consumption on strength, body composition, blood markers of bone, and inflammation in breast cancer survivors (BCS). Twenty-three BCS (RT, n = 12; RT+DP, n = 11), aged 64 ± 7 years, were evaluated at baseline and after 6 months of intervention on the following: muscular strength (chest press and leg extension) via 1-repetition maximums (1RMs); body composition, specifically bone mineral density (BMD) by dual energy X-ray absorptiometry; biochemical markers of bone turnover (bone-specific alkaline phosphatase (BAP), tartrate resistant acid phosphatase (TRAP-5b)); and inflammation (C-reactive protein (CRP)). Target RT prescription was 2 days/week of 10 exercises, including 2 sets of 8-12 repetitions at ∼60%-80% of 1RM. RT+DP also consumed 90 g of DP daily. There were no baseline differences between groups or any group-by-time interactions for any of the variables. BCS increased upper (p body strength. Body composition and BMD improvements were not observed. TRAP-5b decreased in the RT group (p body composition and biochemical markers of inflammation.

  1. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  2. Does Vitamin D Supplementation Enhance Musculoskeletal Performance in Individuals Identified as Vitamin D Deficient through Blood Spot Testing?

    Science.gov (United States)

    Murphy, Kellie A.

    This thesis investigated possible changes in performance after one month of vitamin D supplementation in individuals found to be vitamin D deficient or insufficient through blood spot testing. Thirty-two males, ages 18-32, participated. Each subject visited the lab three times in one-month, completing four performance tests each session, including an isometric mid-thigh pull and a vertical jump on a force plate, a isometric 90-degree elbow flexion test using a load cell, and a psychomotor vigilance test on a palm pilot. The initial lab included blood spot tests to find vitamin D levels. In a single blind manner, 16 subjects were assigned vitamin D and 16 the placebo. Repeated measures ANOVA analysis did not reveal any main effects for time (F=2.626, p=0.364), treatment (vitamin D3 vs placebo; F=1.282, p=0.999), or interaction effects for treatment by time (F=0.304, p=0.999) for maximum force production during an isometric mid-thigh pull. Repeated measures ANOVA analysis did not reveal any main effects for time (F=1.323, p=0.999), treatment (vitamin D3 vs placebo; F=0.510, p=0.999), or interaction effects for treatment by time (F= 1.625, p=0.860) for rate of force production during a vertical jump. Repeated measures ANOVA analysis did not reveal any main effects for time (F=0.194, p=0.999), treatment (vitamin D3 vs placebo; F=2.452, p=0.513), or interaction effects for treatment by time (F= 1.179, p=0.999) for maximal force production during a 90-degree isometric elbow flexion. Repeated measures ANOVA analysis did not reveal any main effects for time (F=1.710, p=0.804), treatment (vitamin D3 vs placebo; F=1.471, p=0.94), or interaction effects for treatment by time (F= 0.293, p=0.999) for mean reaction time to random stimuli during the psychomotor vigilance test. Repeated measures ANOVA analysis did not reveal any main effects for time (F=0.530, p=0.999), treatment (vitamin D3 vs placebo; F=0.141, p=0.999), or interaction effects for treatment by time (F=0.784 p=0

  3. Early detection of Haemonchus contortus infection in sheep using three different faecal occult blood tests

    Directory of Open Access Journals (Sweden)

    A.V. Rodríguez

    2015-07-01

    Full Text Available Haemonchus contortus is a blood-sucking parasite causing the presence of faecal occult blood (FOB. The objective was to study three different FOB tests in order to have a new indicator of H. contortus infection in sheep that could be included in the genetic evaluation system as an alternative selection criterion to faecal worm egg count (FEC. A total of 29 Corriedale lambs were experimentally infected with 10.000 larvae of H. contortus. Stool samples were recorded for FEC and FOB tests (Hexagon, Hematest® and Multistix®, blood for packed cell volume (PCV, haemoglobin, white and red blood cell count (RBC, and FAMACHA© for scoring anaemia. At the end of the experiment lambs were slaughtered to worm burden count. Field infection was achieved in 309 Merino lambs under natural parasite challenge. FEC data were normalized through logarithmic transformation (LnFEC. Pearson correlation was estimated to examine the relationship between all traits. The three tests were able to detect the presence of FOB at day 11. FEC, PCV and RBC decreased to sub-normal values from day 18. FAMACHA© score 3 was considered to be indicative of anaemia. Most of the correlations were of high magnitude, with the exception of Multistix® test that was moderately correlated with haematological parameters, LnFEC and FEC. In field infection, most samples were negative to FOB tests and the correlations were lower than those calculated under experimental infection. In conclusion, FOB tests were able to detect haemonchosis earlier than FEC under high experimental parasite challenge. However, they were not able to detect FOB under natural mixed parasite challenge. FAMACHA© and PCV demonstrated to be good indicators of Haemonchosis, having moderate to high correlations with FEC.

  4. Cirrhosis Diagnosis and Liver Fibrosis Staging: Transient Elastometry Versus Cirrhosis Blood Test.

    Science.gov (United States)

    Calès, Paul; Boursier, Jérôme; Oberti, Frédéric; Bardou, Derek; Zarski, Jean-Pierre; de Lédinghen, Victor

    2015-07-01

    Elastometry is more accurate than blood tests for cirrhosis diagnosis. However, blood tests were developed for significant fibrosis, with the exception of CirrhoMeter developed for cirrhosis. We compared the performance of Fibroscan and CirrhoMeter, and classic binary cirrhosis diagnosis versus new fibrosis staging for cirrhosis diagnosis. The diagnostic population included 679 patients with hepatitis C and liver biopsy (Metavir staging and morphometry), Fibroscan, and CirrhoMeter. The prognostic population included 1110 patients with chronic liver disease and both tests. Binary diagnosis: AUROCs for cirrhosis were: Fibroscan: 0.905; CirrhoMeter: 0.857; and P=0.041. Accuracy (Youden cutoff) was: Fibroscan: 85.4%; CirrhoMeter: 79.2%; and PFibrosis classification provided 6 classes (F0/1, F1/2, F2±1, F3±1, F3/4, and F4). Accuracy was: Fibroscan: 88.2%; CirrhoMeter: 88.8%; and P=0.77. A simplified fibrosis classification comprised 3 categories: discrete (F1±1), moderate (F2±1), and severe (F3/4) fibrosis. Using this simplified classification, CirrhoMeter predicted survival better than Fibroscan (respectively, χ=37.9 and 19.7 by log-rank test), but both predicted it well (Ptest). Comparison: binary diagnosis versus fibrosis classification, respectively, overall accuracy: CirrhoMeter: 79.2% versus 88.8% (PFibrosis classification should be preferred over binary diagnosis. A cirrhosis-specific blood test markedly attenuates the accuracy deficit for cirrhosis diagnosis of usual blood tests versus transient elastometry, and may offer better prognostication.

  5. It’s More Than a Blood Test: Patients’ Perspectives on Noninvasive Prenatal Testing

    Directory of Open Access Journals (Sweden)

    Ruth M. Farrell

    2014-06-01

    Full Text Available Noninvasive prenatal testing (NIPT offers pregnant women a new risk assessment tool for fetal aneuploidy that is superior to conventional screening tests. We conducted focus groups with women who were currently pregnant or had recently delivered in the past year to characterize their perspectives about NIPT and to explore factors they would consider during decision making about its use. Women identified accuracy, early timing, testing ease, and determination of fetal sex as advantages of NIPT over other screens, and the noninvasive method of NIPT as an advantage over diagnostic tests. False positive and false negative results, anxiety, cost and insurance coverage were seen as disadvantages of NIPT. Women who do not want fetal aneuploidy information most likely will not undergo NIPT, despite its advantages over other screening tests. However, given its advantages, the decision to have NIPT is straightforward for women who want genetic information about the fetus. Women emphasized the need to make autonomous, private, and informed choices about NIPT, as they would with any prenatal genetic testing option. These perspectives may guide clinicians to conduct effective and clinically relevant counseling with pregnant women who consider utilizing this new genetic technology.

  6. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic

    OpenAIRE

    Marcelo Carlos Bortoluzzi; Peterson Cadore; Andrea Gallon; Soraia Almeida Watanabe Imanishi

    2014-01-01

    Background: More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the cross-contamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Methods: Traces of invisible blood where randomly searched in CCS of one dental school clinic. Results: Forty eight surfaces areas in the CCS were tes...

  7. The Three-Month Effects of a Ketogenic Diet on Body Composition, Blood Parameters, and Performance Metrics in CrossFit Trainees: A Pilot Study

    Science.gov (United States)

    Kephart, Wesley C.; Pledge, Coree D.; Roberson, Paul A.; Mumford, Petey W.; Romero, Matthew A.; Mobley, Christopher B.; Young, Kaelin C.; Lowery, Ryan P.; Wilson, Jacob M.; Huggins, Kevin W.; Roberts, Michael D.

    2018-01-01

    Adopting low carbohydrate, ketogenic diets remains a controversial issue for individuals who resistance train given that this form of dieting has been speculated to reduce skeletal muscle glycogen levels and stifle muscle anabolism. We sought to characterize the effects of a 12-week ketogenic diet (KD) on body composition, metabolic, and performance parameters in participants who trained recreationally at a local CrossFit facility. Twelve participants (nine males and three females, 31 ± 2 years of age, 80.3 ± 5.1 kg body mass, 22.9 ± 2.3% body fat, 1.37 back squat: body mass ratio) were divided into a control group (CTL; n = 5) and a KD group (n = 7). KD participants were given dietary guidelines to follow over 12 weeks while CTL participants were instructed to continue their normal diet throughout the study, and all participants continued their CrossFit training routine for 12 weeks. Pre, 2.5-week, and 12-week anaerobic performance tests were conducted, and pre- and 12-week tests were performed for body composition using dual X-ray absorptiometry (DXA) and ultrasound, resting energy expenditure (REE), blood-serum health markers, and aerobic capacity. Additionally, blood beta hydroxybutyrate (BHB) levels were measured weekly. Blood BHB levels were 2.8- to 9.5-fold higher in KD versus CTL throughout confirming a state of nutritional ketosis. DXA fat mass decreased by 12.4% in KD (p = 0.053). DXA total lean body mass changes were not different between groups, although DXA dual-leg lean mass decreased in the KD group by 1.4% (p = 0.068), and vastus lateralis thickness values decreased in the KD group by ~8% (p = 0.065). Changes in fasting glucose, HDL cholesterol, and triglycerides were similar between groups, although LDL cholesterol increased ~35% in KD (p = 0.048). Between-group changes in REE, one-repetition maximum (1-RM) back squat, 400 m run times, and VO2peak were similar between groups. While our n-sizes were limited, these preliminary data suggest that

  8. The Three-Month Effects of a Ketogenic Diet on Body Composition, Blood Parameters, and Performance Metrics in CrossFit Trainees: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Wesley C. Kephart

    2018-01-01

    Full Text Available Adopting low carbohydrate, ketogenic diets remains a controversial issue for individuals who resistance train given that this form of dieting has been speculated to reduce skeletal muscle glycogen levels and stifle muscle anabolism. We sought to characterize the effects of a 12-week ketogenic diet (KD on body composition, metabolic, and performance parameters in participants who trained recreationally at a local CrossFit facility. Twelve participants (nine males and three females, 31 ± 2 years of age, 80.3 ± 5.1 kg body mass, 22.9 ± 2.3% body fat, 1.37 back squat: body mass ratio were divided into a control group (CTL; n = 5 and a KD group (n = 7. KD participants were given dietary guidelines to follow over 12 weeks while CTL participants were instructed to continue their normal diet throughout the study, and all participants continued their CrossFit training routine for 12 weeks. Pre, 2.5-week, and 12-week anaerobic performance tests were conducted, and pre- and 12-week tests were performed for body composition using dual X-ray absorptiometry (DXA and ultrasound, resting energy expenditure (REE, blood-serum health markers, and aerobic capacity. Additionally, blood beta hydroxybutyrate (BHB levels were measured weekly. Blood BHB levels were 2.8- to 9.5-fold higher in KD versus CTL throughout confirming a state of nutritional ketosis. DXA fat mass decreased by 12.4% in KD (p = 0.053. DXA total lean body mass changes were not different between groups, although DXA dual-leg lean mass decreased in the KD group by 1.4% (p = 0.068, and vastus lateralis thickness values decreased in the KD group by ~8% (p = 0.065. Changes in fasting glucose, HDL cholesterol, and triglycerides were similar between groups, although LDL cholesterol increased ~35% in KD (p = 0.048. Between-group changes in REE, one-repetition maximum (1-RM back squat, 400 m run times, and VO2peak were similar between groups. While our n-sizes were limited, these preliminary data suggest

  9. Nucleic acid amplification test for detection of west nile virus infection in pakistani blood donors

    International Nuclear Information System (INIS)

    Niazi, S.K.; Alam, M.

    2017-01-01

    Background: The study was planned to determine the presence of West Nile Virus (WNV) infection in Pakistani blood donors, using Nucleic Acid Amplification Test (NAT). Methods: The blood donors for study were selected on the basis of the standard questionnaire and routine screening results. Six donors were pooled using an automated pipettor and NAT for WNV was performed on Roche Cobas s 201 NAT system. The reactive pools were resolved in Individual Donation-NAT (ID-NAT) format and a sample from FFP bags of reactive donations was retrieved. NAT was again performed on retrieved plasma bag (RPB) sample to confirm the reactive donations. The donors were also recalled and interviewed about history of illness related to recent WNV infection. Results: After serological screening of 1929 donors during the study period, 1860 donors were selected for NAT test for WNV detection. The mean age of the donors was 28±8.77 (range: 18–57 years). 1847 (99.3%) donors were male and 13 (0.7%) were female. NAT for WNV identified six initially reactive pools (0.32%). On follow-up testing with RPB samples, 4 donors (0.21%) were found confirmed reactive for WNV RNA (NAT yield of 1 in 465 blood donors). Conclusion: WNV is a threat to safety of blood products in Pakistan. A screening strategy can be implemented after a large-scale study and financial considerations. One of the reduced cost screening strategies is seasonal screening of blood donors for WNV, with pooling of samples. (author)

  10. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  11. [Evaluation of cytomegalovirus quantification in blood by the R-gene real-time PCR test].

    Science.gov (United States)

    Marque-Juillet, S; Touzard, A; Monnier, S; Fernand-Laurent, C; Therby, A; Rigaudeau, S; Harzic, M

    2010-04-01

    Diagnosing the presence of cytomegalovirus (CMV) in the blood of immunodepressed patients is often done by quantitative polymerase chain reaction (Q-PCR) even though the reference method remains the antigenemia pp65 (Ag-pp65) test. To define the predictive value of the Q-PCR in the diagnosis of CMV disease and assess treatment efficacy using the CMV R-gene test. To compare the Q-PCR results and feasibility with those of the Ag-pp65 test. The Q-PCR was performed in 34 whole blood samples (frozen at -80 degrees C until use) from five patients diagnosed with CMV disease, defined as the presence of clinical signs and Ag-pp65 in the nuclei of more than two cells. After extraction, viral DNA was quantified in each sample using the Q-PCR CMV R-gene kit according to the manufacturer's instructions. Immediately after blood was drawn, the Ag-pp65 test had been performed in 32 samples using CINAkit (Argene). The 16 samples positive by the Ag-pp65 test were also positive by PCR; six samples negative by the Ag-pp65 test were positive by PCR; and the remaining 10 samples were negative by both techniques. During treatment, the two markers' kinetics were similar. The CMV R-gene test has a predictive value as good as that of the Ag-pp65 test but is fast and easier to use. A prospective study with a greater number of patients is needed to define the prediction threshold for CMV disease. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  12. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  13. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  14. The Sympathetic Release Test: A Test Used to Assess Thermoregulation and Autonomic Control of Blood Flow

    Science.gov (United States)

    Tansey, E. A.; Roe, S. M.; Johnson, C. J.

    2014-01-01

    When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the…

  15. Study of the cross-reactivity of fish allergens based on a questionnaire and blood testing

    OpenAIRE

    Kobayashi, Yukihiro; Huge, Jiletu; Imamura, Shintaro; Hamada-Sato, Naoko

    2016-01-01

    Background: Parvalbumin and collagen have been identified as cross-reactive allergens for fish allergies. Although doctors realize that various fish elicit allergies, the targets of food allergen labeling laws were only mackerels and salmons in Japan and mackerels in South Korea. This study aimed to reveal the causative species for fish allergy via questionnaires and blood tests. Methods: Questionnaire research was conducted in Japan via the internet concerning allergies for fish-allergic ...

  16. Blood transport method for chromosome analysis of residents living near Semipalatinsk nuclear test site.

    Science.gov (United States)

    Rodzi, Mohd; Ihda, Shozo; Yokozeki, Masako; Takeichi, Nobuo; Tanaka, Kimio; Hoshi, Masaharu

    2009-12-01

    A study was conducted to compare the storage conditions and transportation period for blood samples collected from residents living in areas near the Semipalatinsk nuclear test site (SNTS). Experiments were performed to simulate storage and shipping environments. Phytohaemagglutinin (PHA)-stimulated blood was stored in 15-ml tubes (condition A: current transport method) in the absence or in 50-ml flasks (condition B: previous transport method) in the presence of RPMI-1640 and 20% fetal bovine serum (FBS). Samples were kept refrigerated at 4 degrees C and cell viability was assessed after 3, 8, 12 and 14 days of storage. RPMI-1640, 20% FBS and further PHA were added to blood samples under condition A in 50-ml flasks for culture. Whole-blood samples under condition B were directly incubated without further sub-culturing process, neither media nor PHA were added, to adopt a similar protocol to that employed in the previous transport method. Samples in condition A and condition B were incubated for 48 hr at 37 degrees C and their mitotic index was determined. The results showed that viable lymphocytes were consistent in both storage conditions but the mitotic index was higher in condition A than in condition B. Although further confirmation studies have to be carried out, previous chromosomal studies and the present experiment have shown that PHA-stimulated blood could be stored without culture medium for up to 8 days under condition A. The present results will be useful for cytogenetic analysis of blood samples that have been transported long distances wherever a radiation accident has occurred.

  17. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  18. New method for rapid Susceptibility Testing on blood culture with HB&L system: preliminary data

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2010-12-01

    Full Text Available Blood culture, although represents the gold standard in detecting the ethiological agent of sepsis, is rather rarely required in relation to the real diagnostic importance. The result of this test depends in fact on many factors (sample volume, time of collection, accuracy, antibiotic therapy, contamination, number of drawings, drawing site, interpretation difficulties, etc. that are often considered by many clinicians so limited as to doubt about their actual value. The disadvantages are therefore represented by the lack of standardization but also by the low sensitivity and above all by the technical times too long for the clinical needs. Blood culture begins with the drawing of samples from the “septic” patient followed incubation of the bottles in automatic thermostated systems. In case of positive result (36 hours, the culture is Gram stained and streaked on solid media in order to obtain isolated colonies for the identification and the susceptibility testing (48 hours from positive result. The long time required for pathogen identification and susceptibility testing involves empirical broad spectrum antibiotic therapy that can promote the increase of bacterial resistance but also patient management costs. A clinically useful report should be available on short notice in order to guide the clinician to choose the most appropriate antibiotic. The microbiologist has therefore the hard work of reviewing the organization and the management of the procedures.We have therefore started to consider the possibility of treating the blood as an biological liquid in order to quickly determine the susceptibility of bacteria to antibiotics.

  19. Iodine based radiopacity of experimental blood clots for testing of mechanical thrombectomy devices

    International Nuclear Information System (INIS)

    Luo, Zhong Hua; Chung, Alex; Choi, Gibok; Lin, Yih Huie; Pang, Huajin; Uchida, Barry T.; Pavcnik, Dusan; Jeromel, Miran; Keller, Frederick S.; Rösch, Josef

    2013-01-01

    Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls. In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs

  20. Effects of a 3-month supplementation with a novel soluble highly viscous polysaccharide on anthropometry and blood lipids in nondieting overweight or obese adults.

    Science.gov (United States)

    Lyon, M; Wood, S; Pelletier, X; Donazzolo, Y; Gahler, R; Bellisle, F

    2011-08-01

    High viscosity fibre is known to exert many beneficial effects on appetite and metabolism. It could potentially help in weight management, in dieting or nondieting individuals. The present study investigated the effects of the daily intake of a novel high viscosity polysaccharide (HVP) over 3 months in nondieting obese or overweight men and women. The study comprised a double-blind, randomised controlled clinical trial. Participants ingested 5-15 g per day of either HVP (n = 29, experimental group) or inulin (n = 30, control group) for 15 weeks. Changes in anthropometry (weight, waist and hip circumferences), blood lipids and glucose tolerance were studied from the beginning to the end of administration. Compliance and tolerance were examined. Differences appeared between HVP and inulin supplementation in female participants only. Mean (SD) decreases in body weight [1.6 (3.2) kg; approximately 2% of initial weight] and hip circumference [2.8 (3.6 ) cm] occurred in women of the HVP group but not in controls (Time × Group interactions, P ≤ 0.002). Total, high-density lipoprotein and low-density lipoprotein-cholesterol were lower at the end of supplementation in the women of the HVP group compared to controls (P ≤ 0.021). No effect appeared in waist circumference and triacylglycerol. No difference was noted in the number or severity of the adverse effects reported in both groups. Adverse effects were mild and agreed with commonly reported reactions to intake of dietary fibre. Beneficial although modest effects appeared after several weeks of daily HVP intake in nondieting obese or overweight women. The effects of HVP should be investigated in the context of a weight loss programme. © 2011 The Authors. Journal of Human Nutrition and Dietetics © 2011 The British Dietetic Association Ltd.

  1. Features of changes in concentration of pituitary thyroid hormone and thyroid hormones in the blood of two-month rats with experimental hypothyroidism before and after operations with N-(2-methoxybenzoyl)-O-isopropyl-α, β-dehydrothyrozine choline ester

    International Nuclear Information System (INIS)

    Khachatryan, T.S.; Topuzyan, V.O.

    2013-01-01

    The features of pituitary thyroid hormone concentration and thyroid hormones in the blood of rats with experimental hypothyroidism before and after injections of N-(2-methoxybenzoyl)-O-isopropyl-α, β-dehydrothyrozine choline ester were investigated. A sharp increase of pituitary thyroid hormone level and a sharp decrease of the level of thyroid hormones in the blood of two-month rats with hypothyroidism have been established. Under the action of N-(2-methoxybenzoyl)-O-isopropyl--α, β-dehydrothyrozine choline ester the decrease of pituitary thyroid hormone concentration and the increase of thyroid hormones level in the rats' blood have been observed and reached their values in intact animals

  2. Genetic Testing Confirmed the Early Diagnosis of X-Linked Hypophosphatemic Rickets in a 7-Month-Old Infant

    Directory of Open Access Journals (Sweden)

    Kok Siong Poon BSc

    2015-08-01

    Full Text Available Loss-of-function mutations in the p hosphate regulating gene with h omologies to e ndopeptidases on the X -chromosome ( PHEX have been causally associated with X-linked hypophosphatemic rickets (XLHR. The early diagnosis of XLHR in infants is challenging when it is based solely on clinical features and biochemical findings. We report a 7-month-old boy with a family history of hypophosphatemic rickets., who demonstrated early clinical evidence of rickets, although serial biochemical findings could not definitively confirm rickets. A sequencing assay targeting the PHEX gene was first performed on the mother’s DNA to screen for mutations in the 5′UTR, 22 coding exons, and the exon-intron junctions. Targeted mutation analysis and mRNA studies were subsequently performed on the boys’ DNA to investigate the pathogenicity of the identified mutation. Genetic screening of the PHEX gene revealed a novel mutation, c.1080-2A>C, at the splice acceptor site in intron 9. The detection of an aberrant mRNA transcript with skipped (loss of exon 10 establishes its pathogenicity and confirms the diagnosis of XLHR in this infant. Genetic testing of the PHEX gene resulted in early diagnosis of XLHR, thus enabling initiation of therapy and prevention of progressive rachitic changes in the infant.

  3. Evaluation for secondary causes of headache: the role of blood and urine testing.

    Science.gov (United States)

    Loder, Elizabeth; Cardona, Luzma

    2011-02-01

    Most patients presenting for evaluation of headache meet diagnostic criteria for a benign, primary headache disorder based on history and physical examination findings alone. No further testing is needed in such cases. Additional diagnostic evaluation is needed in cases that do not meet criteria for a primary headache disorder or which are associated with unusual or worrisome features. This article will review secondary causes of headache listed in the International Classification of Headache Disorders-II in which blood and urine testing might aid in diagnosis. We offer recommendations for diagnostic evaluation when these disorders are suspected causes of headache. © 2011 American Headache Society.

  4. Determinants of participation in colorectal cancer screening with faecal occult blood testing

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Brasso, Klaus; Lynge, Elsebeth

    2009-01-01

    BACKGROUND: Colorectal cancer is one of the most common cancers in men and women. Participation rates in faecal occult blood testing (FOBT) screening activities are, however, relatively low. In terms of lowering the colorectal cancer mortality, high participation rates are essential, and therefore......, but determinants varied across countries and test settings. There was no systematic variation in participation across age groups. CONCLUSION: The participation pattern depends in part on local circumstances, which makes it difficult to point to a general strategy for increasing the uptake in FOBT screening...

  5. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  6. Detecting a low prevalence of latent tuberculosis among health care workers in Denmark detected by M. tuberculosis specific IFN-gamma whole-blood test

    DEFF Research Database (Denmark)

    Soborg, Bolette; Andersen, Aase B; Larsen, Helle K

    2007-01-01

    The study was designed to estimate prevalence of tuberculosis infection among health care workers, using the tuberculin skin test (TST) and the new M. tuberculosis specific diagnostic whole-blood test and to identify possible risk factors. Employees at 2 departments of infectious diseases...... as the remaining 45 TST positive participants showed no sign of active tuberculous disease and were allocated to 6-month clinical follow-up, without medical therapy. Today, 1.5 y later, all remain healthy. The high rate of positive TST among health care workers was most probably due to BCG vaccination...

  7. The determination of phenazone in blood plasma for obtained sistem suitable test of monitoring drug level

    Directory of Open Access Journals (Sweden)

    Mochamad Lazuardi

    2007-09-01

    Full Text Available The determining of Phenazone to human blood plasma from healthy man after separated by solid phase extraction (SPE and spectroscopic measurements has been investigated. The objective of that research was to obtain system suitable test for determine the Phenazone level in biological fluids (human blood plasma, for new performed dosage regimented in clinical dentistry. The method can be divided into the following four steps. 1. Centrifugation the blood sample, 2. Extraction from blood plasma and, 3. Separation by SPE with manual pressured, 4. Elution to SPE followed by the measurement on a spectrophotometer in the ultra violet region. The critical value of  │t │at the 5% confidence level indicates that there is no systematic error in the linearity proposed method. Recoveries for this research were obtained at ranging 93.460 to 95.598%. The coefficient variation precision of this procedure was clearly good at smallest than 2%. The analytical procedure can be carried out in one working operation as a monitored therapeutic activity.

  8. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    Science.gov (United States)

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a

  9. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    Science.gov (United States)

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  10. Analysis of Macular Drusen and Blood Test Results in 945 Macaca fascicularis.

    Directory of Open Access Journals (Sweden)

    Koji M Nishiguchi

    Full Text Available Age-dependent formation of macular drusen caused by the focal accumulation of extracellular deposits beneath the retinal pigment epithelium precede the development of age-related macular degeneration (AMD, one of the leading causes of blindness worldwide. It is established that inflammation contributes to the pathogenesis of drusen and AMD. However, development of a preemptive therapeutic strategy targeting macular drusen and AMD has been impeded by the lack of relevant animal models because most laboratory animals lack macula, an anatomic feature present only in humans and a subset of monkeys. Reportedly, macular drusen and macular degeneration develop in monkeys in an age-dependent manner. In this study, we analyzed blood test results from 945 Macaca fascicularis, 317 with and 628 without drusen. First, a trend test for drusen frequency (the Cochran-Armitage test was applied to the quartile data for each parameter. We selected variables with an increasing or decreasing trend with higher quartiles at P < 0.05, to which multivariate logistic regression analysis was applied. This revealed a positive association of age (odds ratio [OR]: 1.10 per year, 95% confidence interval [CI]: 1.07-1.12 and white blood cell count (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.01 with drusen. When the monkeys were divided by age, the association between drusen and white blood cell count was only evident in younger monkeys (OR: 1.01 per 1 × 103/μl, 95% CI: 1.00-1.02. In conclusion, age and white blood cell count may be associated with drusen development in M. fascicularis. Systemic inflammation may contribute to drusen formation in monkeys.

  11. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures

    Directory of Open Access Journals (Sweden)

    Hong-wei Pan

    2018-03-01

    Full Text Available Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  12. Evaluation of serum lysyl oxidase as a blood test for colorectal cancer.

    Science.gov (United States)

    Ward, S T; Weston, C J; Hepburn, E; Damery, S; Hejmadi, R K; Morton, D G; Middleton, G; Ismail, T; Adams, D H

    2014-06-01

    Lysyl oxidase (LOX) expression is elevated in colorectal cancer (CRC) tissue and associated with disease progression. A blood test may form a more acceptable diagnostic test for CRC although LOX has not previously been measured in the serum. We therefore sought to determine the clinical usefulness of a serum LOX test for CRC in a symptomatic population. Adult patients referred to a hospital colorectal clinic with bowel symptoms completed a questionnaire and provided a blood sample for serum LOX measurement. Associations between presenting symptoms, serum LOX concentrations and outcomes of investigations were tested by univariate and multivariate analyses to determine if serum LOX was clinically useful in the prediction of CRC. LOX expression in CRC and adjacent colon biopsies was evaluated by ELISA and immunohistochemistry. Thirty-one cases of colorectal cancer and 16 high-risk polyps were identified from a total of 962 participants. There was no association between serum LOX concentration and the presence of CRC, high-risk polyps or cancers at any site. LOX expression was significantly increased in CRC tissue compared to adjacent colon. Despite overexpression of LOX in CRC tissue, elevated serum levels could not be demonstrated. Serum LOX measurement is therefore not a clinically useful test for CRC. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  14. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    Science.gov (United States)

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  15. The donor line break cannula: effect on the donation process, blood component quality and transfusion microbiology testing of an important new blood bag safety feature.

    Science.gov (United States)

    Nightingale, M J; Beard, M J; Bennett, J; Hambleton, R; Ramskill, S; Thomas, S

    2013-08-01

    The use of blood packs with an integral sampling system can result in anti-coagulant from the main bag reaching the sample pouch via the donor line, causing delayed coagulation of blood samples. In NHS Blood and Transplant, this has prevented the use of serum, the preferred matrix for transfusion microbiology (TM) testing, which has led to an increased false positive rate with ethylenediaminetetraacetic acid (EDTA) plasma. There is also a remote possibility of false negative results owing to sample dilution. Manufacturers have responded by offering packs with a donor line break cannula (DLBC) to prevent these adverse effects. The aims of this study were to assess the impact of DLBC packs on donation, blood component quality and of the potential return to serum for TM testing. DLBC packs from three manufacturers were assessed against control packs of the same dimensions and configuration. Donation duration, flow rate, platelet factor 4, prothrombin fragment 1+2, haemolysis and collection and processing incidents were compared. Results indicated no clinically significant adverse effect from the DLBC on the activation state of platelets, the coagulation cascade or increased haemolysis. Donation duration and blood collection and processing incident rates for DLBC packs were not significantly different to controls. The use of DLBC packs would reduce the complexity of manipulations during blood collection and therefore the likelihood of microbially contaminated donations (incorrect skin core diversion) and false negative TM tests. DLBC packs would enable the use of serum for TM testing with a significant reduction in false positive tests compared to EDTA plasma. © 2013 The Authors. Transfusion Medicine © 2013 British Blood Transfusion Society.

  16. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    Science.gov (United States)

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  17. FibroMeters: a family of blood tests for liver fibrosis.

    Science.gov (United States)

    Calès, P; Boursier, J; Oberti, F; Hubert, I; Gallois, Y; Rousselet, M-C; Dib, N; Moal, V; Macchi, L; Chevailler, A; Michalak, S; Hunault, G; Chaigneau, J; Sawadogo, A; Lunel, F

    2008-09-01

    FibroMeters are blood tests for liver fibrosis with several specificities: two main diagnostic targets (fibrosis stage and area of fibrosis); adaptation to specific causes; and results confirmed by an expert system. Thus, FibroMeters comprise six different tests: one for staging and one for quantitation of liver fibrosis in each of the three main causes of chronic liver disease-chronic viral hepatitis, alcoholic liver disease (ALD) and non-alcoholic fatty liver disease (NAFLD). FibroMeters display a high overall diagnostic accuracy and are the only tests to correctly classify 100% of HCV patients without fibrosis or with cirrhosis. They have 90% predictive values in a higher proportion of patients than with other usual blood tests. A 90% correct classification is available in 100% of HCV patients with the following reliable diagnostic intervals: F0/1, F1/2, F2+/-1, F3+/-1. In real-life conditions, the reproducibility of FibroMeters is higher than that of liver biopsy or ultrasonographic elastometry. FibroMeters are robust tests with the most stable diagnostic performance across different centers. Optional tests are also available, such as a specific one for cirrhosis, which has a diagnostic accuracy of 93.0% (AUROC: 0.92) and a 100% positive predictive value for diagnosis of HCV cirrhosis. Determination by FibroMeters of the area of fibrosis - the only direct, non-invasive, quantitative measurement of liver fibrosis - are especially useful for following-up cirrhosis as it correlates well with clinical events. FibroMeters are also very accurate in HVB or HIV-HCV co-infected patients. The tests specific for ALD and NAFLD also have a high diagnostic accuracy (AUROCs: 0.96 and 0.94, respectively, for significant fibrosis).

  18. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic.

    Science.gov (United States)

    Bortoluzzi, Marcelo Carlos; Cadore, Peterson; Gallon, Andrea; Imanishi, Soraia Almeida Watanabe

    2014-10-01

    More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the crosscontamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Traces of invisible blood where randomly searched in CCS of one dental school clinic. Forty eight surfaces areas in the CCS were tested and the presence of invisible and remnant blood was identified in 28 (58.3%) items. We suggest that the luminol method is suitable for identifying contamination with invisible blood traces and this method may be a useful tool to prevent cross-contamination in the dental care setting.

  19. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  20. Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests.

    Science.gov (United States)

    Felipo, Vicente; Urios, Amparo; Giménez-Garzó, Carla; Cauli, Omar; Andrés-Costa, Maria-Jesús; González, Olga; Serra, Miguel A; Sánchez-González, Javier; Aliaga, Roberto; Giner-Durán, Remedios; Belloch, Vicente; Montoliu, Carmina

    2014-09-07

    To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy. Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE were detected using the battery Psychometric Hepatic Encephalopathy Score (PHES) consisting of five tests. Different cognitive and motor functions were also assessed: alterations in selective attention were evaluated using the Stroop test. Patients and controls also performed visuo-motor and bimanual coordination tests. Several biochemical parameters were measured: serum pro-inflammatory interleukins (IL-6 and IL-18), 3-nitrotyrosine, cGMP and nitrates+nitrites in plasma, and blood ammonia. Bivariate correlations were evaluated. In patients with MHE, BF was increased in cerebellar hemisphere (P = 0.03) and vermis (P = 0.012) and reduced in occipital lobe (P = 0.017). BF in cerebellar hemisphere was also increased in patients without MHE (P = 0.02). Bimanual coordination was impaired in patients without MHE (P = 0.05) and much more in patients with MHE (P battery and with CFF. BF in cerebellar hemisphere correlates with plasma cGMP and nitric oxide (NO) metabolites. BF in vermis cerebellar also correlates with NO metabolites and with 3-nitrotyrosine. IL-18 in plasma correlates with BF in thalamus and occipital lobe. Non invasive BF determination in cerebellum using ASL may detect MHE earlier than the PHES. Altered NO-cGMP pathway seems to be associated to altered BF in cerebellum.

  1. In vivo red blood cell compatibility testing using indium-113m tropolone-labeled red blood cells

    International Nuclear Information System (INIS)

    Morrissey, G.J.; Gravelle, D.; Dietz, G.; Driedger, A.A.; King, M.; Cradduck, T.D.

    1988-01-01

    In vivo radionuclide crossmatch is a method for identifying compatible blood for transfusion when allo- or autoantibodies preclude the use of conventional crossmatching techniques. A technique for labeling small volumes of donor red blood cells with [/sup 113m/In]tropolone is reported. The use of /sup 113m/In minimizes the accumulation of background radioactivity and the radiation dose especially so when multiple crossmatches are performed. Labeling red cells with [/sup 113m/In]tropolone is faster and easier to perform than with other radionuclides. Consistently high labeling efficiencies are obtained and minimal /sup 113m/In activity elutes from the labeled red blood cells. A case study involving 22 crossmatches is presented to demonstrate the technique. The radiation dose equivalent from /sup 113m/In is significantly less than with other radionuclides that may be used to label red cells

  2. Improving Detection of Prediabetes in Children and Adults: Using Combinations of Blood Glucose Tests

    Directory of Open Access Journals (Sweden)

    Ike Solomon Okosun

    2015-11-01

    Full Text Available Aim: To determine combinations of blood glucose tests: oral glucose tolerance (OGT, fasting plasma glucose (FBG and hemoglobin A1C (HbA1C that are associated with highest diagnostic rates of prediabetes in non-diabetic American children and adults.Methods: The 2007-2008 U.S. National Health and Nutrition Examination Surveys data were used for this study. Overall and specific prevalence of prediabetes (defined using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were determined across age, race/ethnicity, sex and BMI categories.Results: FPG+HbA1C test was associated with significantly higher diagnostic rates of prediabetes across age, race/ethnicity and BMI. Estimates of overall prevalence of prediabetes using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were 20.3%, 24.2%, 33% and 34.3%, respectively. Compared to OGT+FPG, the use of HbA1C+FPG test in screening was associated with 44.8%, 135%, 38.6% and 35.9% increased prevalence of prediabetes in non-Hispanic White, non-Hispanic Black, Mexican-American and other racial/ethnic men, respectively. The corresponding values in women were 67.8%, 140%, 37.2% and 42.6%, respectively. Combined use of all blood glucose tests did not improve the overall and gender-specific prediabetes prevalence beyond what was observed using HbA1C+FPG test.Conclusions: HbA1C criteria were associated with higher diagnosis rates of prediabetes than FPG and OGT tests in non-diabetic American children and adults. Using a combination of HbA1C and FPG test in screening for prediabetes reduces intrinsic systematic bias in using just HbA1C testing and offers the benefits of each test. A well-defined HbA1C that takes into consideration race/ethnicity, gender, age and body mass index may improve detection of prediabetes in population and clinical settings.

  3. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  4. Comparison of liver fibrosis blood tests developed for HCV with new specific tests in HIV/HCV co-infection.

    Science.gov (United States)

    Calès, Paul; Halfon, Philippe; Batisse, Dominique; Carrat, Fabrice; Perré, Philippe; Penaranda, Guillaume; Guyader, Dominique; d'Alteroche, Louis; Fouchard-Hubert, Isabelle; Michelet, Christian; Veillon, Pascal; Lambert, Jérôme; Weiss, Laurence; Salmon, Dominique; Cacoub, Patrice

    2010-08-01

    We compared 5 non-specific and 2 specific blood tests for liver fibrosis in HCV/HIV co-infection. Four hundred and sixty-seven patients were included into derivation (n=183) or validation (n=284) populations. Within these populations, the diagnostic target, significant fibrosis (Metavir F > or = 2), was found in 66% and 72% of the patients, respectively. Two new fibrosis tests, FibroMeter HICV and HICV test, were constructed in the derivation population. Unadjusted AUROCs in the derivation population were: APRI: 0.716, Fib-4: 0.722, Fibrotest: 0.778, Hepascore: 0.779, FibroMeter: 0.783, HICV test: 0.822, FibroMeter HICV: 0.828. AUROCs adjusted on classification and distribution of fibrosis stages in a reference population showed similar values in both populations. FibroMeter, FibroMeter HICV and HICV test had the highest correct classification rates in F0/1 and F3/4 (which account for high predictive values): 77-79% vs. 70-72% in the other tests (p=0.002). Reliable individual diagnosis based on predictive values > or = 90% distinguished three test categories: poorly reliable: Fib-4 (2.4% of patients), APRI (8.9%); moderately reliable: Fibrotest (25.4%), FibroMeter (26.6%), Hepascore (30.2%); acceptably reliable: HICV test (40.2%), FibroMeter HICV (45.6%) (ptests). FibroMeter HICV classified all patients into four reliable diagnosis intervals ( or =F1, > or =F2) with an overall accuracy of 93% vs. 79% (pfibrosis. Tests designed for HCV infections are less effective in HIV/HCV infections. A specific test, like FibroMeter HICV, was the most interesting test for diagnostic accuracy, correct classification profile, and a reliable diagnosis. With reliable diagnosis intervals, liver biopsy can therefore be avoided in all patients. Copyright 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  5. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  6. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    Science.gov (United States)

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  7. Predictive Value of Whole Blood and Plasma Coagulation Tests for Intra- and Postoperative Bleeding Risk: A Systematic Review

    DEFF Research Database (Denmark)

    Larsen, Julie Brogaard; Hvas, Anne-Mette

    2017-01-01

    review of the existing literature assessing the ability of whole blood coagulation (thromboelastography [TEG]/thromboelastometry [ROTEM]/Sonoclot), platelet function tests, and standard plasma-based coagulation tests to predict bleeding in the perioperative setting. We searched PubMed and Embase...... value of testing in patients receiving antithrombotic medication. In general, studies reported low positive predictive values for perioperative testing, whereas negative predictive values were high. The studies yielded moderate areas under receiver operator characteristics (ROC) curve (for the majority...... recommend that both whole blood and plasma-based coagulation tests are primarily used in case of bleeding and not for screening in unselected patients prior to surgery....

  8. Prognostic significance of blood coagulation tests in carcinoma of the lung and colon.

    Science.gov (United States)

    Wojtukiewicz, M Z; Zacharski, L R; Moritz, T E; Hur, K; Edwards, R L; Rickles, F R

    1992-08-01

    Blood coagulation test results were collected prospectively in patients with previously untreated, advanced lung or colon cancer who entered into a clinical trial. In patients with colon cancer, reduced survival was associated (in univariate analysis) with higher values obtained at entry to the study for fibrinogen, fibrin(ogen) split products, antiplasmin, and fibrinopeptide A and accelerated euglobulin lysis times. In patients with non-small cell lung cancer, reduced survival was associated (in univariate analysis) with higher fibrinogen and fibrin(ogen) split products, platelet counts and activated partial thromboplastin times. In patients with small cell carcinoma of the lung, only higher activated partial thromboplastin times were associated (in univariate analysis) with reduced survival in patients with disseminated disease. In multivariate analysis, higher activated partial thromboplastin times were a significant independent predictor of survival for patients with non-small cell lung cancer limited to one hemithorax and with disseminated small cell carcinoma of the lung. Fibrin(ogen) split product levels were an independent predictor of survival for patients with disseminated non-small cell lung cancer as were both the fibrinogen and fibrinopeptide A levels for patients with disseminated colon cancer. These results suggest that certain tests of blood coagulation may be indicative of prognosis in lung and colon cancer. The heterogeneity of these results suggests that the mechanism(s), intensity, and pathophysiological significance of coagulation activation in cancer may differ between tumour types.

  9. Toward laboratory blood test-comparable photometric assessments for anemia in veterinary hematology

    Science.gov (United States)

    Kim, Taehoon; Choi, Seung Ho; Lambert-Cheatham, Nathan; Xu, Zhengbin; Kritchevsky, Janice E.; Bertin, Francois-René; Kim, Young L.

    2016-10-01

    Anemia associated with intestinal parasites and malnutrition is the leading cause of morbidity and mortality in small ruminants worldwide. Qualitative scoring of conjunctival redness has been developed so that farmers can gauge anemia in sheep and goats to identify animals that require treatment. For clinically relevant anemia diagnosis, complete blood count-comparable quantitative methods often rely on complicated and expensive optical instruments, requiring detailed spectral information of hemoglobin. We report experimental and numerical results for simple, yet reliable, noninvasive hemoglobin detection that can be correlated with laboratory-based blood hemoglobin testing for anemia diagnosis. In our pilot animal study using calves, we exploit the third eyelid (i.e., palpebral conjunctiva) as an effective sensing site. To further test spectrometer-free (or spectrometerless) hemoglobin assessments, we implement full spectral reconstruction from RGB data and partial least square regression. The unique combination of RGB-based spectral reconstruction and partial least square regression could potentially offer uncomplicated instrumentation and avoid the use of a spectrometer, which is vital for realizing a compact and inexpensive hematology device for quantitative anemia detection in the farm field.

  10. Development of an Intervention for implementing Immunochemical Faecal Occult Blood Test in General Practice

    DEFF Research Database (Denmark)

    Juul, Jakob Søgaard; Vedsted, Peter; Bro, Flemming

    2016-01-01

    Denne korte artikel handler om udviklingen af en intervention til implementering af immunochemical faecal occult blood test (iFOBT) i almen praksis. Artiklen gennemgår processen fra de tidlige udviklingsstadier, over pilot-testning og frem til de endelige justeringer før selve implementeringen blev...... vurdering og viden om patienten. Kombinationen af teori og praksis viste sig at være en god måde at sikre hurtig ibrugtagning af en ny test i almen praksis til at identificere potentielle tegn på tarmkræft hos patienter. Særligt pilot-testning af interventionen viste sig at være værdifuld, fordi den...

  11. Visible but Unseen? A Workplace Study of Blood-Test Icons on Electronic Emergency-Department Whiteboard

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdóttir á; Hertzum, Morten

    2015-01-01

    Studies have shown that whiteboards support much cooperative work by for example strengthening awareness, improving communication, and reducing mental workload. In line with these predominantly positive findings, an emer-gency department (ED) turned to its whiteboard to improve the coordination...... of its work with blood tests. We investigate this use of the whiteboard through observations and in-formal interviews in the ED and analyze the ability of the whiteboard to support coordination and awareness in the work with blood tests. Our findings show limitations in the ability of the whiteboard...... to support awareness in a setting where the users are (locally) mobile, specifically in regard to information that requires continuous monitoring. We do however also find that the whiteboard safeguarded the work with blood tests against some risks by making blood-test information socially visible...

  12. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    Science.gov (United States)

    Nadiy, I.; Razalee, S.; Zalifah, M. K.; Zulkeffeli, M. J.

    2013-11-01

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m2, 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, pselected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, pattention to the existence of overweight and obesity as well as the risk of non-communicable diseases among military population. Therefore, future intervention from the aspect of nutritional education and health awareness can benefit thus optimizing the health status of MA military personnel.

  13. Which is more useful in predicting hospital mortality--dichotomised blood test results or actual test values? A retrospective study in two hospitals.

    Science.gov (United States)

    Mohammed, Mohammed A; Rudge, Gavin; Wood, Gordon; Smith, Gary; Nangalia, Vishal; Prytherch, David; Holder, Roger; Briggs, Jim

    2012-01-01

    Routine blood tests are an integral part of clinical medicine and in interpreting blood test results clinicians have two broad options. (1) Dichotomise the blood tests into normal/abnormal or (2) use the actual values and overlook the reference values. We refer to these as the "binary" and the "non-binary" strategy respectively. We investigate which strategy is better at predicting the risk of death in hospital based on seven routinely undertaken blood tests (albumin, creatinine, haemoglobin, potassium, sodium, urea, and white blood cell count) using tree models to implement the two strategies. A retrospective database study of emergency admissions to an acute hospital during April 2009 to March 2010, involving 10,050 emergency admissions with routine blood tests undertaken within 24 hours of admission. We compared the area under the Receiver Operating Characteristics (ROC) curve for predicting in-hospital mortality using the binary and non-binary strategy. The mortality rate was 6.98% (701/10050). The mean predicted risk of death in those who died was significantly (p-value non-binary strategy (risk = 0.222 95%CI: 0.194 to 0.251), representing a risk difference of 28.74 deaths in the deceased patients (n = 701). The binary strategy had a significantly (p-value non-binary strategy (0.853 95% CI: 0.840 to 0.867). Similar results were obtained using data from another hospital. Dichotomising routine blood test results is less accurate in predicting in-hospital mortality than using actual test values because it underestimates the risk of death in patients who died. Further research into the use of actual blood test values in clinical decision making is required especially as the infrastructure to implement this potentially promising strategy already exists in most hospitals.

  14. Which Is More Useful in Predicting Hospital Mortality -Dichotomised Blood Test Results or Actual Test Values? A Retrospective Study in Two Hospitals

    Science.gov (United States)

    Mohammed, Mohammed A.; Rudge, Gavin; Wood, Gordon; Smith, Gary; Nangalia, Vishal; Prytherch, David; Holder, Roger; Briggs, Jim

    2012-01-01

    Background Routine blood tests are an integral part of clinical medicine and in interpreting blood test results clinicians have two broad options. (1) Dichotomise the blood tests into normal/abnormal or (2) use the actual values and overlook the reference values. We refer to these as the “binary” and the “non-binary” strategy respectively. We investigate which strategy is better at predicting the risk of death in hospital based on seven routinely undertaken blood tests (albumin, creatinine, haemoglobin, potassium, sodium, urea, and white blood cell count) using tree models to implement the two strategies. Methodology A retrospective database study of emergency admissions to an acute hospital during April 2009 to March 2010, involving 10,050 emergency admissions with routine blood tests undertaken within 24 hours of admission. We compared the area under the Receiver Operating Characteristics (ROC) curve for predicting in-hospital mortality using the binary and non-binary strategy. Results The mortality rate was 6.98% (701/10050). The mean predicted risk of death in those who died was significantly (p-value non-binary strategy (risk = 0.222 95%CI: 0.194 to 0.251), representing a risk difference of 28.74 deaths in the deceased patients (n = 701). The binary strategy had a significantly (p-value non-binary strategy (0.853 95% CI: 0.840 to 0.867). Similar results were obtained using data from another hospital. Conclusions Dichotomising routine blood test results is less accurate in predicting in-hospital mortality than using actual test values because it underestimates the risk of death in patients who died. Further research into the use of actual blood test values in clinical decision making is required especially as the infrastructure to implement this potentially promising strategy already exists in most hospitals. PMID:23077528

  15. Immunochemical faecal occult blood tests have superior stability and analytical performance characteristics over guaiac-based tests in a controlled in vitro study.

    LENUS (Irish Health Repository)

    Lee, Chun Seng

    2011-06-01

    The aims of this study were (1) to determine the measurement accuracy of a widely used guaiac faecal occult blood test (gFOBT) compared with an immunochemical faecal occult blood test (iFOBT) during in vitro studies, including their analytical stability over time at ambient temperature and at 4°C; and (2) to compare analytical imprecision and other characteristics between two commercially available iFOBT methods.

  16. Improved fibrosis staging by elastometry and blood test in chronic hepatitis C.

    Science.gov (United States)

    Calès, Paul; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Hubert, Isabelle; Hunault, Gilles; de Lédinghen, Victor; Zarski, Jean-Pierre; Salmon, Dominique; Lunel, Françoise

    2014-07-01

    Our main objective was to improve non-invasive fibrosis staging accuracy by resolving the limits of previous methods via new test combinations. Our secondary objectives were to improve staging precision, by developing a detailed fibrosis classification, and reliability (personalized accuracy) determination. All patients (729) included in the derivation population had chronic hepatitis C, liver biopsy, 6 blood tests and Fibroscan. Validation populations included 1584 patients. The most accurate combination was provided by using most markers of FibroMeter and Fibroscan results targeted for significant fibrosis, i.e. 'E-FibroMeter'. Its classification accuracy (91.7%) and precision (assessed by F difference with Metavir: 0.62 ± 0.57) were better than those of FibroMeter (84.1%, P fibrosis absence (F0) was increased, e.g. from 16.0% with Fibroscan to 75.0% with E-FibroMeter (P test (1.2% of patients) and increasing optimal reliability (accuracy ≥85%) from 80.4% of patients with Fibroscan (accuracy: 90.9%) to 94.2% of patients with E-FibroMeter (accuracy: 92.9%), P test (FibroMeter: 16.2%, P test combination increased: accuracy, globally and especially in patients without fibrosis, staging precision, cirrhosis prediction, and even reliability, thus offering improved fibrosis staging. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing

    International Nuclear Information System (INIS)

    Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi

    2015-01-01

    There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (∼5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells’ trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip’s functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood. (paper)

  18. The A[subscript 1c] Blood Test: An Illustration of Principles from General and Organic Chemistry

    Science.gov (United States)

    Kerber, Robert C.

    2007-01-01

    The glycated hemoglobin blood test, usually designated as the A[subscript 1c] test, is a key measure of the effectiveness of glucose control in diabetics. The chemistry of glucose in the bloodstream, which underlies the test and its impact, provides an illustration of the importance of chemical equilibrium and kinetics to a major health problem.…

  19. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  20. Blood tests in tired elite athletes: expectations of athletes, coaches and sport science/sports medicine staff.

    Science.gov (United States)

    Fallon, K E

    2007-01-01

    The issue of the expectations of elite athletes, their coaches and non-medically qualified athlete support staff of consultations with sports physicians has not been previously dealt with in the sports medicine literature. As fulfillment of expectations of the content of a consultation may influence patient's satisfaction and clinical outcome, it is important to assess the expectations of athletes and, most importantly, coaches. To assess the expectations and beliefs about fatigue, particularly in relation to blood tests, of athletes, their coaches and support staff in the specific context of tiredness of sports science or non-medically qualified sports medicine staff, 22 elite coaches and 62 elite athletes from the Australian Institute of Sport were included in this study. A single questionnaire. The expectation for a blood test at the initial consultation for short-term fatigue was particularly high among athletes (81%) and coaches (91%). This expectation increased in athletes if their performance was worsening. All groups unanimously suggested that a blood test be performed in cases of more prolonged fatigue. Increase in total training load was perceived to be the most important cause of fatigue, but issues relating to sleep were also thought to be highly relevant. All groups suggested that blood tests provide some degree of reassurance, and all groups suggested that the most important blood tests that might be performed related to exclusion of iron deficiency, anaemia and infection. Athletes and their coaches generally expect that blood tests will be performed even when fatigue has been present for performed.

  1. Dry blood spot testing for hepatitis C in people who injected drugs: reaching the populations other tests cannot reach.

    Science.gov (United States)

    Tait, J M; Stephens, Brian P; McIntyre, Paul G; Evans, Morgan; Dillon, John F

    2013-10-01

    The aim of the study was to evaluate the effectiveness of Dry Blood Spot testing (DBST) for hepatitis C within a geographical area. This is a prospective cohort study of all individuals living in Tayside who had received a hepatitis C virus (HCV) DBST between 2009 and 2011. During the study, 1123 DBSTs were carried out. 946 individuals had one test. 295 (31.2%) of these individuals were HCV antibody positive on their first test. Overall, 94.3% (902/956) individuals returned for the results of their test. During the course of the study 177 individuals were retested and 29 new cases of hepatitis C were detected. 249 individuals attended for further follow-up, and 164 (65.5%) were PCR positive. All 164 PCR-positive individuals were offered referral into specialist HCV services for further assessment. Data showed 62.5% were genotype 3, 65.1% had a low viral load (<600 000 iu/ml) and 77.5% had a Fibroscan score below 7 KPa. To date, 40 have commenced treatment and a further 16 are currently in the assessment period. Overall, we have retained in services or treated 63.6% (105/164) of patients who were initially referred and with effective support mechanisms in place we have achieved sustained viral response rates of 90%. The study has shown that DBST is a complementary technique to conventional venepuncture for the diagnosis of HCV. The majority of patients have low viral loads and low fibrosis scores, so that while this group of patients may be difficult to reach and may be challenging to maintain in therapy, they are easier to cure.

  2. Prehospital point of care testing of blood gases and electrolytes — an evaluation of IRMA

    OpenAIRE

    Prause, Gerhard; Ratzenhofer-Komenda, Beatrice; Offner, Anton; Lauda, Peter; Voit, Henrika; Pojer, Horst

    1997-01-01

    Background: This study evaluated the feasibility of blood gas analysis and electrolyte measurements during emergency transport prior to hospital admission. Results: A portable, battery-powered blood analyzer was used on patients in life threatening conditions to determine pH, pCO2, pO2, sodium, potassium and ionized calcium. Arterial blood was used for blood gas analysis and electrolyte measurements. Venous blood was used for electrolyte measurement alone. During the observation period of 4 m...

  3. Assessment of platelet function in healthy sedated cats using three whole blood platelet function tests.

    Science.gov (United States)

    Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2015-05-01

    The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).

  4. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    Science.gov (United States)

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    Energy Technology Data Exchange (ETDEWEB)

    Nadiy, I.; Razalee, S.; Zalifah, M. K. [Nutrition Programme, School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia,43600, Selangor (Malaysia); Zulkeffeli, M. J. [Department of Health Service, Ministry of Defense, Level 11, Menara Park, 50450 (Malaysia)

    2013-11-27

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m{sup 2}, 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, p<0.05), WC (r=0.852, p<0.05) and body fat percentage. Body fat percentage also show high correlation with weight (r=0.759, p<0.05) and WC (r=0.768, p<0.05. The result from 173 of 378 subjects that were selected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, p<0.05), BMI (r=0.243, p<0.05), WC (r=0.298, p<0.05), body fat percentage (r=0.163, p<0.05) and age (r=0.223, p<0.05). Random blood cholesterol level had significant correlation with

  6. Nutritional status and random blood glucose, cholesterol and triglyceride test among Malaysian Army (MA) personnel in Kuala Lumpur

    International Nuclear Information System (INIS)

    Nadiy, I.; Razalee, S.; Zalifah, M. K.; Zulkeffeli, M. J.

    2013-01-01

    With the rising trend of obesity among the general population, it is also important to assess the obesity and health status among military population. The aim of this study was to determine the prevalence of overweight and obesity among Malaysian Army (MA) personnel as well as the relationship between selected socio-demographics factors, antropometric profiles, body composition and random blood test value. A cross sectional study involving 378 male military personnel aged between 20 to 48 years old was conducted at two MA bases in Kuala Lumpur between November and December 2012. Antropometric measurements included height, weight and waist circumference (WC). Body fat percentage was measured using bioelectrical impedance analysis method (Tanita TBF-300A). Mean height, weight, BMI, WC, body fat percentage, age, monthly income and duration of service were 1.71 ± 0.6 m, 71.7 ± 12.2 kg, 24.6 ± 4.1 kg/m 2 , 87.0 ± 10.0 cm, 23.4 ± 6.6%, 29.1 ± 5.5 years, RM 2115.12 ± 860.70 and 9.9 ± 5.6 years respectively. According to WHO (1998) classification of BMI, 3.2% of the subjects were underweight, 54.8% normal, 32.8% overweight and 9.3% obese. It was obeserved that 40.2% of the subjects had waist circumference value of 90 cm or more and were considered high risk for diebetes and cardiovascular diseases. This study found that BMI was highly correlated with weight (r=0.925, p<0.05), WC (r=0.852, p<0.05) and body fat percentage. Body fat percentage also show high correlation with weight (r=0.759, p<0.05) and WC (r=0.768, p<0.05. The result from 173 of 378 subjects that were selected for random blood test found that 4.6%, 3.5% and 26.0% had diabetes, high cholesterol and high triglyceride respectively. There was a weak correlation between random blood glucose level with weight (r=0.221, p<0.05), BMI (r=0.243, p<0.05), WC (r=0.298, p<0.05), body fat percentage (r=0.163, p<0.05) and age (r=0.223, p<0.05). Random blood cholesterol level had significant correlation with weight

  7. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    Science.gov (United States)

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  8. The Two-Tier Fecal Occult Blood Test: Cost-Effective Screening

    Directory of Open Access Journals (Sweden)

    Andrew J Rae

    1994-01-01

    Full Text Available The two-tier test represents a strategy combining HO Sensa and Hemeselect fecal occult blood tests (FOBTs with the aim of greater specificity and consequent economic advantages. If patients register a positive result on any HO Sensa guaiac test, they are once again tested by a hemoglobin-specific Hemeselect test. This concept was applied to a multicentre study involving persons 40 years or older. One component of the study enrolled 573 high risk patients while the second arm recruited an additional 1301 patients (52% asymptomatic/48% symptomatic stratified according to personal history and symptoms. The two-tier test produced fewer false positives than traditional tests in both groups evaluated in the study. In the high risk group, specificity (88.7% for two-tier versus 80.6% for Hemoccult and 69.5% for HO Sensa was higher and false positive rates were lower (11.3% for two-tier versus 19.5% for Hemoccultand 30.5% for HO Sensa for the two-tier test versus Hemoccult and HO Sensa FOBTs (95% CI for all colorectal cancers [CRCs] and polyps greater than 1 cm, α=0.05 . No significant differences in sensitivity were observed between tests in the same group. Also, in the high risk group, benefits of the two-tier test outweighed the costs. Due to the small number of cancers and polyps in the second arm of the study, presentation of data is meant to be descriptive and representative of trends in a ‘normal’ population. Nevertheless, specificity of the two-tier test was higher (96.8% for two-tier versus 87.2% for Hemoccult and 69.5% for HO Sensa and false positive rate lower (3.2% for two-tier versus 12.8% for Hemoccult and 22.3% for HO Sensa than either the Hemoccult or HO Sensa FOBT (95% CI for all CRCs and polyps greater than 1 cm. This initial study, focusing on the cost-benefit relationship of increased specificity, represents a new way of economically evaluating existing FOBTs.

  9. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-10-15

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.

  10. Operational feasibility of using whole blood in the rapid HIV testing algorithm of a resource-limited settings like Bangladesh.

    Science.gov (United States)

    Munshi, Saif U; Oyewale, Tajudeen O; Begum, Shahnaz; Uddin, Ziya; Tabassum, Shahina

    2016-03-01

    Serum-based rapid HIV testing algorithm in Bangladesh constitutes operational challenge to scaleup HIV testing and counselling (HTC) in the country. This study explored the operational feasibility of using whole blood as alternative to serum for rapid HIV testing in Bangladesh. Whole blood specimens were collected from two study groups. The groups included HIV-positive patients (n = 200) and HIV-negative individuals (n = 200) presenting at the reference laboratory in Dhaka, Bangladesh. The specimens were subjected to rapid HIV tests using the national algorithm with A1 = Alere Determine (United States), A2 = Uni-Gold (Ireland), and A3 = First Response (India). The sensitivity and specificity of the test results, and the operational cost were compared with current serum-based testing. The sensitivities [95% of confidence interval (CI)] for A1, A2, and A3 tests using whole blood were 100% (CI: 99.1-100%), 100% (CI: 99.1-100%), and 97% (CI: 96.4-98.2%), respectively, and specificities of all test kits were 100% (CI: 99.1-100%). Significant (P < 0.05) reduction in the cost of establishing HTC centre and consumables by 94 and 61%, respectively, were observed. The cost of administration and external quality assurance reduced by 39 and 43%, respectively. Overall, there was a 36% cost reduction in total operational cost of rapid HIV testing with blood when compared with serum. Considering the similar sensitivity and specificity of the two specimens, and significant cost reduction, rapid HIV testing with whole blood is feasible. A review of the national HIV rapid testing algorithm with whole blood will contribute toward improving HTC coverage in Bangladesh.

  11. Comparison of nine blood tests and transient elastography for liver fibrosis in chronic hepatitis C: the ANRS HCEP-23 study.

    Science.gov (United States)

    Zarski, Jean-Pierre; Sturm, Nathalie; Guechot, Jérôme; Paris, Adeline; Zafrani, Elie-Serge; Asselah, Tarik; Boisson, Renée-Claude; Bosson, Jean-Luc; Guyader, Dominique; Renversez, Jean-Charles; Bronowicki, Jean-Pierre; Gelineau, Marie-Christine; Tran, Albert; Trocme, Candice; De Ledinghen, Victor; Lasnier, Elisabeth; Poujol-Robert, Armelle; Ziegler, Frédéric; Bourliere, Marc; Voitot, Hélène; Larrey, Dominique; Rosenthal-Allieri, Maria Alessandra; Fouchard Hubert, Isabelle; Bailly, François; Vaubourdolle, Michel

    2012-01-01

    Blood tests and transient elastography (Fibroscan™) have been developed as alternatives to liver biopsy. This ANRS HCEP-23 study compared the diagnostic accuracy of nine blood tests and transient elastography (Fibroscan™) to assess liver fibrosis, vs. liver biopsy, in untreated patients with chronic hepatitis C (CHC). This was a multicentre prospective independent study in 19 French University hospitals of consecutive adult patients having simultaneous liver biopsy, biochemical blood tests (performed in a centralized laboratory) and Fibroscan™. Two experienced pathologists independently reviewed the liver biopsies (mean length=25±8.4 mm). Performance was assessed using ROC curves corrected by Obuchowski's method. Fibroscan™ was not interpretable in 113 (22%) patients. In the 382 patients having both blood tests and interpretable Fibroscan™, Fibroscan™ performed similarly to the best blood tests for the diagnosis of significant fibrosis and cirrhosis. Obuchowski's measure showed Fibrometer® (0.86), Fibrotest® (0.84), Hepascore® (0.84), and interpretable Fibroscan™ (0.84) to be the most accurate tests. The combination of Fibrotest®, Fibrometer®, or Hepascore® with Fibroscan™ or Apri increases the percentage of well classified patients from 70-73% to 80-83% for significant fibrosis, but for cirrhosis a combination offers no improvement. For the 436 patients having all the blood tests, AUROC's ranged from 0.82 (Fibrometer®) to 0.75 (Hyaluronate) for significant fibrosis, and from 0.89 (Fibrometer® and Hepascore®) to 0.83 (FIB-4) for cirrhosis. Contrarily to blood tests, performance of Fibroscan™ was reduced due to uninterpretable results. Fibrotest®, interpretable Fibroscan™, Fibrometer®, and Hepascore® perform best and similarly for diagnosis of significant fibrosis and cirrhosis. Copyright © 2011 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  12. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  13. Is TB Testing Associated With Increased Blood Interferon-Gamma Levels?

    Directory of Open Access Journals (Sweden)

    Aideen E. Kennedy

    2017-10-01

    Full Text Available The Republic of Ireland reports a relatively low prevalence of Johne’s disease (JD compared to international counterparts. Postulated reasons for this include a lower average herd size and a grass-based production system. Ireland also engages in high levels of bovine tuberculosis (bTB testing. As interferon-gamma (IFN-γ is believed to play a key role in protecting against JD, it is our hypothesis that administration of purified protein derivative (PPD, as part of the bTB test, is associated with a systemic increase in IFN-γ production, which may potentially limit clinical progression of the disease. We studied 265 cows (202 Friesian and 63 “Non-Friesian,” e.g., JerseyX, Norwegian Red to assess IFN-γ levels and Mycobacterium avium subspecies paratuberculosis (MAP antibody response before and after the bTB test. As part of the compulsory annual bTB test, avian and bovine PPD were administered at two separate cervical sites. To assess IFN-γ production, blood samples were taken before and 72 h after PPD administration. MAP antibody response was assessed before and 10 days post-PPD administration. A significant increase in MAP antibody response was identified post-bTB compared to pre-bTB response (p < 0.001. Additionally, IFN-γ production significantly increased at the post-bTB time point (p < 0.001 compared to the pre-bTB test readings. This may indicate a beneficial effect of bTB testing in controlling JD.

  14. A new rapid method for direct antimicrobial susceptibility testing of bacteria from positive blood cultures.

    Science.gov (United States)

    Barnini, Simona; Brucculeri, Veronica; Morici, Paola; Ghelardi, Emilia; Florio, Walter; Lupetti, Antonella

    2016-08-12

    Rapid identification and antimicrobial susceptibility testing (AST) of the causative agent(s) of bloodstream infections can lead to prompt appropriate antimicrobial therapy. To shorten species identification, in this study bacteria were recovered from monomicrobial blood cultures by serum separator tubes and spotted onto the target plate for direct MALDI-TOF MS identification. Proper antibiotics were selected for direct AST based on species identification. In order to obtain rapid AST results, bacteria were recovered from positive blood cultures by two different protocols: by serum separator tubes (further referred to as PR1), or after a short-term subculture in liquid medium (further referred to as PR2). The results were compared with those obtained by the method currently used in our laboratory consisting in identification by MALDI-TOF and AST by Vitek 2 or Sensititre on isolated colonies. The direct MALDI-TOF method concordantly identified with the current method 97.5 % of the Gram-negative bacteria and 96.1 % of the Gram-positive cocci contained in monomicrobial blood cultures. The direct AST by PR1 and PR2 for all isolate/antimicrobial agent combinations was concordant/correct with the current method for 87.8 and 90.5 % of Gram-negative bacteria and for 93.1 and 93.8 % of Gram-positive cocci, respectively. In particular, 100 % categorical agreement was found with levofloxacin for Enterobacteriaceae by both PR1 and PR2, and 99.0 and 100 % categorical agreement was observed with linezolid for Gram-positive cocci by PR1 and PR2, respectively. There was no significant difference in accuracy between PR1 and PR2 for Gram-negative bacteria and Gram-positive cocci. This newly described method seems promising for providing accurate AST results. Most importantly, these results would be available in a few hours from blood culture positivity, which would help clinicians to promptly confirm or streamline an effective antibiotic therapy in patients with bloodstream

  15. Detecting a low prevalence of latent tuberculosis among health care workers in Denmark detected by M. tuberculosis specific IFN-gamma whole-blood test

    DEFF Research Database (Denmark)

    Soborg, Bolette; Andersen, Aase B; Larsen, Helle K

    2007-01-01

    The study was designed to estimate prevalence of tuberculosis infection among health care workers, using the tuberculin skin test (TST) and the new M. tuberculosis specific diagnostic whole-blood test and to identify possible risk factors. Employees at 2 departments of infectious diseases...... as the remaining 45 TST positive participants showed no sign of active tuberculous disease and were allocated to 6-month clinical follow-up, without medical therapy. Today, 1.5 y later, all remain healthy. The high rate of positive TST among health care workers was most probably due to BCG vaccination...... TST whereas only 2 of 139 (1%) had a positive QuantiFERON TB-Gold test (QFT-TB). 42 of 106 (40%) BCG vaccinated had positive TST (> or =12 mm) compared with 2 of 27 (7%) unvaccinated persons. Among 47 persons with positive TST, 42 (89%) were BCG- vaccinated. The 2 QFT-TB positive participants as well...

  16. Effect of centrifuge test on blood serum lipids index of cadet pilots.

    Science.gov (United States)

    Wochyński, Zbigniew; Kowalczuk, Krzysztof; Kłossowski, Marek; Sobiech, Krzysztof A

    2016-01-01

    This study aimed at investigating the relationship between the lipid index (WS) in the examined cadets and duration of exposure to +Gz in the human centrifuge. The study involved 19 first-year cadets of the Polish Air Force Academy in Dęblin. Tests in the human centrifuge were repeated twice, i.e. prior to (test I) and 45 days after (test II). After exposure to +Gz, the examined cadets were divided into 2 groups. Group I (N=11) included cadets subjected to a shorter total duration of exposure to +Gz, while group II (N=8) included cadets with a longer total duration of exposure to +Gz. Total cholesterol (TC), high density lipoprotein (HDL), triglycerides (TG), and apolipoproteins A1 and B were assayed in blood serum prior to (assay A) and after (assay B) both exposures to +Gz. Low density lipoprotein (LDL) level was estimated from the Friedewald formula. WS is an own mathematical algorithm. WS was higher in group II, assay A - 10.0 and B - 10.08 of test I in the human centrifuge than in group I where the WS values were 6.91 and 6.96, respectively. WS was also higher in group II in assay A - 10.0 and B -10.1 of test II in the human centrifuge than in group I - 6.96 and 6.80, respectively. The higher value of WS in group II, both after the first and second exposure to +Gz in human centrifuge, in comparison with group I, indicated its usefulness for determination of the maximum capability of applying acceleration of the interval type during training in the human centrifuge.

  17. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  18. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  19. Red Blood Cell Antibody Screen: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/redbloodcellantibodyscreen.html Red Blood Cell Antibody Screen To use the sharing features on this page, please enable JavaScript. What is an RBC Antibody Screen? An RBC (red blood cell) antibody screen ...

  20. Factors influencing oral hygiene behaviour and gingival outcomes 3 and 12 months after initial periodontal treatment: an exploratory test of an extended Theory of Reasoned Action.

    Science.gov (United States)

    Jönsson, Birgitta; Baker, Sarah R; Lindberg, Per; Oscarson, Nils; Ohrn, Kerstin

    2012-02-01

    The aim was to empirically test the extended Theory of Reasoned Action (TRA) and the prospective direct and indirect role of attitudes, beliefs, subjective norms, self-efficacy, and a cognitive behavioural intervention in adult's oral hygiene behaviour and gingival outcomes at 3- and 12-month follow-up. Data were derived from an RCT evaluating the effectiveness of oral hygiene educational programs integrated in non-surgical periodontal treatment (n = 113). Before baseline examination, participants completed a self-report questionnaire. Structural equation modelling using maximum likelihood estimation with bootstrapping was used to test the direct and indirect (mediated) pathways within the extended TRA model. The extended TRA model explained a large amount of variance in gingival outcome scores at 12 months (56%). A higher level of self-efficacy at baseline was associated with higher frequencies of oral hygiene behaviour at 3 months. Being female was linked to more normative beliefs that, in turn, related to greater behavioural beliefs and self-efficacy. Gender was also related to behavioural beliefs, attitudes and subjective norms. Both frequency of oral hygiene behaviour at 3 months and the cognitive behavioural intervention predicted gingival outcome at 12 months. The model demonstrated that self-efficacy, gender and a cognitive behavioural intervention were important predictors of oral hygiene behavioural change. © 2011 John Wiley & Sons A/S.

  1. Rapid identification and antimicrobial susceptibility testing of positive blood cultures using MALDI-TOF MS and a modification of the standardised disc diffusion test: a pilot study.

    LENUS (Irish Health Repository)

    Fitzgerald, C

    2016-04-27

    In an era when clinical microbiology laboratories are under increasing financial pressure, there is a need for inexpensive, yet effective, rapid microbiology tests. The aim of this study was to evaluate a novel modification of standard methodology for the identification and antimicrobial susceptibility testing (AST) of pathogens in positive blood cultures, reducing the turnaround time of laboratory results by 24 h.

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ... de Cure Women's Series Do-It-Yourself Fundraising Become a Volunteer American Diabetes Month® American Diabetes Association ...

  3. BLOOD DOPING AND RISKS

    Directory of Open Access Journals (Sweden)

    Goran Vasić

    2015-05-01

    Full Text Available Doping is the way in which athletes misuse of chemicals and other types of medical interventions (eg, blood replacement, try to get ahead in the results of other athletes or their performance at the expense of their own health. The aim of this work is the analysis of blood doping and the display of negative consequences that this way of increasing capabilities brings. Method: The methodological work is done descriptively. Results: Even in 1972 at the Stockholm Institute for gymnastics and sport, first Dr. Bjorn Ekblom started having blood doping. Taken from the blood, athletes through centifuge separating red blood cells from blood plasma, which is after a month of storage in the fridge, every athlete back into the bloodstream. Tests aerobic capacity thereafter showed that the concerned athletes can run longer on average for 25% of the treadmill than before. Discussion: Blood doping carries with it serious risks, excessive amount of red cells “thickens the blood,” increased hematocrit, which reduces the heart’s ability to pump blood to the periphery. All this makes it difficult for blood to flow through blood vessels, and there is a great danger that comes to a halt in the circulation, which can cause cardiac arrest, stroke, pulmonary edema, and other complications that can be fatal.

  4. Development and testing of a new disposable sterile device for labelling white blood cells

    NARCIS (Netherlands)

    Signore, A.; Glaudemans, A. W. J. M.; Malviya, G.; Lazzeri, E.; Prandini, N.; Viglietti, A. L.; De Vries, E. F. J.; Dierckx, R. A. J. O.

    Aim. White blood cell (WBC) labelling requires isolation of cells from patient's blood under sterile conditions using sterile materials, buffers and disposables under good manufacturing practice (GMP) conditions. Till now, this limited the use of white blood cell scintigraphy (WBC-S) only to well

  5. The risk of transfusion-transmitted HIV from blood donations of men who have sex with men, 12 months after last sex with a man: 2005-2007 estimates from England and Wales.

    Science.gov (United States)

    Davison, K L; Conti, S; Brailsford, S R

    2013-07-01

    The risk of transfusion-transmitted HIV infection under (i) permanent exclusion and (ii) 12-month deferral of MSM in England and Wales during 2005-2007 was estimated. Assuming equal compliance with both scenarios, estimated risk under a 12-month deferral (0.228/million donations [range 0·168-0·306/million donations]) was only marginally greater (0·5%) than that under lifetime exclusion (0·227/million donations [range 0·157-0.318/million donations]), with one extra-HIV infectious donation every 455 years. Poorer compliance of MSM with a 12-month deferral would be expected to increase the estimated risk, whereas improved compliance could decrease risk by up to 29·1%. © 2013 International Society of Blood Transfusion.

  6. Roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction.

    Science.gov (United States)

    Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing

    2012-01-01

    It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences

  7. Decreases in blood ethanol concentrations during storage at 4 °C for 12 months were the same for specimens kept in glass or plastic tubes

    Directory of Open Access Journals (Sweden)

    A.W. Jones

    2016-04-01

    Full Text Available Background: The stability of ethanol was investigated in blood specimens in glass or plastic evacuated tubes after storage in a refrigerator at 4 °C for up to 12 months. Methods: Sterile blood, from a local hospital, was divided into 50 mL portions and spiked with aqueous ethanol (10% w/v to give target concentrations of 0.20, 1.00, 2.00 and 3.00 g/L. Ethanol was determined in blood by headspace gas chromatography (HS-GC with an analytical imprecision of <3% (coefficient of variation, CV%. Aliquots of blood were re-analysed after 2, 7, 14, 28, 91, 182 and 364 days of storage at 4 °C. Results: The standard deviation (SD of analysis by HS-GC was 0.0059 g/L at 0.20 g/L and 0.0342 g/L at 3.00 g/L, corresponding to CVs of 2.9% and 1.1%, respectively. The decreases in blood ethanol content were analytically significant after 14–28 days of storage for both glass and plastic tubes The mean (lowest and highest loss of ethanol after 12 months storage was 0.111 g/L (0.084–0.129 g/L for glass tubes and 0.112 g/L (0.088–0.140 g/L for plastic tubes. The corresponding percentage losses of ethanol were 43–45% at a starting concentration of 0.20 g/L and 3.9–4.1% at 3.00 g/L. Conclusion: The concentration of ethanol in blood gradually decreases during storage at 4 °C. After 12 months storage the absolute decrease in concentration was ~0.11 g/L when the starting concentration ranged from 0.20 to 3.0 g/L. Decreases in ethanol content were the same for specimens kept in glass or plastic evacuated tubes. Keywords: Alcohol, Analysis, Blood, Ethanol stability, Plastic vs glass tubes, Storage conditions

  8. A novel approach to detect test-seeking behaviour in the blood donor population : making the invisible visible

    NARCIS (Netherlands)

    de Vos, A. S.; Lieshout-Krikke, R. W.; Slot, E.; Cator, E. A.; Janssen, M. P.

    2016-01-01

    Background and Objectives: Individuals may donate blood in order to determine their infection status after exposure to an increased infection risk. Such test-seeking behaviour decreases transfusion safety. Instances of test seeking are difficult to substantiate as donors are unlikely to admit to

  9. Blood test ordering for unexplained complaints in general practice: the VAMPIRE randomised clinical trial protocol. [ISRCTN55755886

    NARCIS (Netherlands)

    van Bokhoven, Marloes A.; Koch, Hèlen; van der Weijden, Trudy; Grol, Richard P. T. M.; Bindels, Patrick J. E.; Dinant, Geert-Jan

    2006-01-01

    BACKGROUND: General practitioners (GPs) frequently order blood tests when they see patients presenting with unexplained complaints. Due to the low prevalence of serious pathology in general practice, the risk of false-positive test results is relatively high. This may result in unnecessary further

  10. Fecal occult blood test for colorectal cancer screening: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    The colorectal cancer (CRC) screening project was undertaken by the Medical Advisory Secretariat (MAS) in collaboration with the Cancer Care Ontario (CCO).In November 2007, the Ontario Health Technology Advisory Committee (OHTAC) MAS to conduct an evidence-based analysis of the available data with respect to colorectal cancer diagnosis and prevention. The general purpose of the project was to investigate the effectiveness, cost effectiveness, and safety of the various methods and techniques used for colorectal cancer screening in average risk people, 50 years of age and older.The options currently offered for colorectal cancer screening were reviewed and five technologies were selected for review:Computed tomographic (CT) colonographyMagnetic resonance (MR) colonographyWireless capsule endoscopy (PillCam Colon)Fecal occult blood test (FOBT)Flexible sigmoidoscopyIn this review, colonoscopy was considered as the "gold standard" technique by which the effectiveness of all other modalities could be evaluated. An economic analysis was also conducted to determine cost-effectiveness of different screening modalities.Evidence-based analyses have been prepared for each of these technologies, as well as summary document that includes an economic analysis, all of which are presented at the MAS Web site: http://www.health.gov.on.ca/english/providers/program/mas/tech/techmn.html The objective of this evidence review is to examine the effectiveness and cost-effectiveness of fecal occult blood testing (FOBT), including guaiac FOBT (gFOBT) and immunochemical FOBT (iFOBT), for use in colorectal cancer (CRC) screening in asymptomatic, average-risk adults. Specifically: Is the use of gFOBT or iFOBT associated with a reduction in CRC and overall mortality?What are the sensitivity and specificity of gFOBT and iFOBT for the detection of 1) CRC and 2) large polyps (≥ 1 cm)? CRC is the most common cause of non-tobacco related cancer death in Canada. It has been estimated that in 2007, 7

  11. Is it possible to predict the presence of colorectal cancer in a blood test? A probabilistic approach method.

    Science.gov (United States)

    Navarro Rodríguez, José Manuel; Gallego Plazas, Javier; Borrás Rocher, Fernando; Calpena Rico, Rafael; Ruiz Macia, José Antonio; Morcillo Ródenas, Miguel Ángel

    2017-10-01

    The assessment of the state of immunosurveillance (the ability of the organism to prevent the development of neoplasias) in the blood has prognostic implications of interest in colorectal cancer. We evaluated and quantified a possible predictive character of the disease in a blood test using a mathematical interaction index of several blood parameters. The predictive capacity of the index to detect colorectal cancer was also assessed. We performed a retrospective case-control study of a comparative analysis of the distribution of blood parameters in 266 patients with colorectal cancer and 266 healthy patients during the period from 2009 to 2013. Statistically significant differences (p indexes (neutrophil to lymphocyte ratio and platelet to lymphocyte ratio), hemoglobin, hematocrit and eosinophil levels. These differences allowed the design of a blood analytical profile that calculates the risk of colorectal cancer. This risk profile can be quantified via a mathematical formula with a probabilistic capacity to identify patients with the highest risk of the presence of colorectal cancer (area under the ROC curve = 0.85). We showed that a colorectal cancer predictive character exists in blood which can be quantified by an interaction index of several blood parameters. The design and development of interaction indexes of blood parameters constitutes an interesting research line for the development and improvement of programs for the screening of colorectal cancer.

  12. Is it possible to predict the presence of colorectal cancer in a blood test?: a probabilistic approach method

    Directory of Open Access Journals (Sweden)

    José Manuel Navarro-Rodríguez

    Full Text Available Introduction: The assessment of the state of immunosurveillance (the ability of the organism to prevent the development of neoplasias in the blood has prognostic implications of interest in colorectal cancer. We evaluated and quantified a possible predictive character of the disease in a blood test using a mathematical interaction index of several blood parameters. The predictive capacity of the index to detect colorectal cancer was also assessed. Methods: We performed a retrospective case-control study of a comparative analysis of the distribution of blood parameters in 266 patients with colorectal cancer and 266 healthy patients during the period from 2009 to 2013. Results: Statistically significant differences (p < 0.05 were observed between patients with colorectal cancer and the control group in terms of platelet counts, fibrinogen, total leukocytes, neutrophils, systemic immunovigilance indexes (neutrophil to lymphocyte ratio and platelet to lymphocyte ratio, hemoglobin, hematocrit and eosinophil levels. These differences allowed the design of a blood analytical profile that calculates the risk of colorectal cancer. This risk profile can be quantified via a mathematical formula with a probabilistic capacity to identify patients with the highest risk of the presence of colorectal cancer (area under the ROC curve = 0.85. Conclusions: We showed that a colorectal cancer predictive character exists in blood which can be quantified by an interaction index of several blood parameters. The design and development of interaction indexes of blood parameters constitutes an interesting research line for the development and improvement of programs for the screening of colorectal cancer.

  13. Exaggerated blood pressure response to early stages of exercise stress testing and presence of hypertension.

    Science.gov (United States)

    Schultz, Martin G; Picone, Dean S; Nikolic, Sonja B; Williams, Andrew D; Sharman, James E

    2016-12-01

    Exaggerated exercise blood pressure (EEBP) recorded during exercise testing at moderate-intensity is independently associated with cardiovascular mortality. It is hypothesized that EEBP may be indicative of underlying hypertension unnoticed by standard clinic (resting) BP measures (thus explaining increased mortality risk), but this has never been confirmed by association with hypertension defined using ambulatory BP monitoring, which was the aim of this study. Cross-sectional study. 100 consecutive patients free from coronary artery disease (aged 56±9 years, 72% male) underwent clinically indicated exercise stress testing. Exercise BP was recorded at each stage of the Bruce protocol. Presence of hypertension was defined as 24-hour systolic BP ≥130mmHg or daytime systolic BP ≥135mmHg. Exercise systolic BP at stage 1 and 2 of the test was significantly associated with the presence of hypertension (P130mmHg (AUC=0.752, 95% CI's 0.649-0.846, P150mmHg predicting hypertension independently of age, sex and in-clinic hypertension status (OR=4.83, 95% CI's 1.62-14.39, P=0.005). Irrespective of resting BP, systolic BP ≥150mmHg during early stages of the Bruce exercise stress test is associated with presence of hypertension. EEBP should be a warning signal to health/exercise professionals on the presence of hypertension and the need to provide follow up care to reduce cardiovascular risk. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Sickle cell test

    Science.gov (United States)

    ... cell anemia Sickle cell trait Iron deficiency or blood transfusions within the past 3 months can cause a " ... slight risk any time the skin is broken) Alternative Names Sickledex; Hgb S test Images Red blood cells, sickle cell Red blood cells, multiple sickle ...

  15. Detection of colorectal serrated polyps by stool DNA testing: comparison with fecal immunochemical testing for occult blood (FIT.

    Directory of Open Access Journals (Sweden)

    Russell I Heigh

    Full Text Available Precursors to 1/3 of colorectal cancer (CRC, serrated polyps have been under-detected by screening due to their inconspicuous, non-hemorrhagic, and proximal nature. A new multi-target stool DNA test (multi-target sDNA shows high sensitivity for both CRC and advanced adenomas. Screen detection of serrated polyps by this approach requires further validation. We sought to assess and compare noninvasive detection of sessile serrated polyps (SSP ≥ 1 cm by sDNA and an occult blood fecal immunochemical test (FIT.In a blinded prospective study, a single stool sample used for both tests was collected from 456 asymptomatic adults prior to screening or surveillance colonoscopy (criterion standard. All 29 patients with SSP ≥ 1 cm were included as cases and all 232 with no neoplastic findings as controls. Buffered stool samples were processed and frozen on receipt; Exact Sciences performed sDNA in batches using optimized analytical methods. The sDNA multi-marker panel targets methylated BMP3 (mBMP3 and NDRG4, mutant KRAS, β-actin, and hemoglobin. FIT (Polymedco OC-FIT Check was performed in separate lab ≤ 2 days post defecation and evaluated at cutoffs of 50 (FIT-50 and 100 ng/ml (FIT-100.MEDIAN AGES: cases 61 (range 57-77, controls 62 (52-70, p = NS. Women comprised 59% and 51%, p = NS, respectively. SSP median size was 1.2 cm (1-3 cm, 93% were proximal, and 64% had synchronous diminutive polyps. Among multi-target sDNA markers, mBMP3 proved highly discriminant for detection of SSP ≥ 1 cm (AUC = 0.87, p<0.00001; other DNA markers provided no incremental sensitivity. Hemoglobin alone showed no discrimination (AUC = 0.50, p = NS. At matched specificities, detection of SSP ≥ 1 cm by stool mBMP3 was significantly greater than by FIT-50 (66% vs 10%, p = 0.0003 or FIT-100 (63% vs 0%, p<0.0001.In a screening and surveillance setting, SSP ≥ 1 cm can be detected noninvasively by stool assay of exfoliated DNA markers, especially mBMP3. FIT appears to

  16. Different effect of psyllium and guar dietary supplementation on blood pressure control in hypertensive overweight patients: a six-month, randomized clinical trial.

    Science.gov (United States)

    Cicero, Arrigo F G; Derosa, Giuseppe; Manca, Marco; Bove, Marilisa; Borghi, Claudio; Gaddi, Antonio V

    2007-08-01

    In the setting of a six-month, open-label clinical trial, 141 consecutively enrolled, hypertensive, overweight patients were randomized to the oral ingestion of psyllium powder or guar gum 3.5 gr t.i.d., to be taken 20 min before the main two meals, or to standard diet. Both fibers improved significantly BMI, FPG, FPI, HOMA Index, HbA1c, LDL-C, and ApoB. Psyllium supplementation only exerted a significant improvement in plasma TG concentration, in SBP and DBP. In our study, six-month supplementation with psyllium fiber, but not with guar fiber nor standard diet, appears to significantly reduce both SBP and DBP in hypertensive overweight subjects.

  17. A Single Test Combining Blood Markers and Elastography is More Accurate Than Other Fibrosis Tests in the Main Causes of Chronic Liver Diseases.

    Science.gov (United States)

    Ducancelle, Alexandra; Leroy, Vincent; Vergniol, Julien; Sturm, Nathalie; Le Bail, Brigitte; Zarski, Jean Pierre; Nguyen Khac, Eric; Salmon, Dominique; de Ledinghen, Victor; Calès, Paul

    2017-08-01

    International guidelines suggest combining a blood test and liver stiffness measurement (LSM) to stage liver fibrosis in chronic hepatitis C (CHC) and non-alcoholic fatty liver disease (NAFLD). Therefore, we compared the accuracies of these tests between the main etiologies of chronic liver diseases. Overall, 1968 patients were included in 5 etiologies: CHC: 698, chronic hepatitis B: 152, human immunodeficiency virus/CHC: 628, NAFLD: 225, and alcoholic liver disease (ALD): 265. Sixteen tests [13 blood tests, LSM (Fibroscan), 2 combined: FibroMeters] were evaluated. References were Metavir staging and CHC etiology. Accuracy was evaluated mainly with the Obuchowski index (OI) and accessorily with area under the receiver operating characteristics (F≥2, F≥3, cirrhosis). OIs in CHC were: FibroMeters: 0.812, FibroMeters: 0.785 to 0.797, Fibrotest: 0.762, CirrhoMeters: 0.756 to 0.771, LSM: 0.754, Hepascore: 0.752, FibroMeter: 0.750, aspartate aminotransferase platelet ratio index: 0.742, Fib-4: 0.741. In other etiologies, most tests had nonsignificant changes in OIs. In NAFLD, CHC-specific tests were more accurate than NAFLD-specific tests. The combined FibroMeters had significantly higher accuracy than their 2 constitutive tests (FibroMeters and LSM) in at least 1 diagnostic target in all etiologies, except in ALD where LSM had the highest OI, and in 3 diagnostic targets (OIs and 2 area under the receiver operating characteristics) in CHC and NAFLD. Some tests developed in CHC outperformed other tests in their specific etiologies. Tests combining blood markers and LSM outperformed single tests, validating recent guidelines and extending them to main etiologies. Noninvasive fibrosis evaluation can thus be simplified in the main etiologies by using a unique test: either LSM alone, especially in ALD, or preferably combined to blood markers.

  18. Post-partum trend in blood pressure levels, renal function and proteinuria in women with severe preeclampsia and eclampsia in Sub-Saharan Africa: a 6-months cohort study.

    Science.gov (United States)

    Kaze, Francois Folefack; Njukeng, Francis A; Kengne, Andre-Pascal; Ashuntantang, Gloria; Mbu, Robinson; Halle, Marie Patrice; Asonganyi, Tazoacha

    2014-04-09

    Preeclampsia and eclampsia, which are the most frequent hypertensive disorders in pregnancy, are associated with renal involvements. We aimed to assess the time trend in blood pressure levels, renal function and proteinuria after delivery, and investigate their determinants in Cameroonian women with severe preeclampsia and eclampsia. This was a prospective cohort study involving 54 women with severe preeclampsia and eclampsia, conducted between July 2010 and February 2012 at the central maternity unit of the Yaoundé Central Hospital. Clinical and laboratory parameters were recorded from day-1 to 6 months after delivery. Mixed-linear and logistic regression models were used to relate baseline and within follow-up levels of covariates, with changes in blood pressure levels, renal function and proteinuria, as well as persisting hypertension, renal failure and proteinuria. During follow-up, a significant improvement was observed in blood pressure, renal function and proteinuria (all p post-delivery, respectively. Corresponding figures for persisting hypertension were 23 (42.6%), 15 (27.8%) and 8 (14.8%). Advanced age, higher body mass index, low gestational age at delivery, low fetal birth weight, and proteinuria at delivery were the main risk factors for persisting hypertension at 3 months, meanwhile low fetal birth weight, severe preeclampsia and proteinuria at delivery were correlated with persisting proteinuria at 3 months. Advanced age and higher body mass index were the only determinants of the composite outcome of persisting hypertension or proteinuria at three and six months. Hypertension and proteinuria are very common beyond the postpartum period in Cameroonian women with severe preeclampsia and eclampsia. Long-term follow-up of these women will help preventing and controlling related complications.

  19. Fibrosis progression under maintenance interferon in hepatitis C is better detected by blood test than liver morphometry.

    Science.gov (United States)

    Calès, P; Zarski, J P; Chapplain, J Marc; Bertrais, S; Sturm, N; Michelet, C; Babany, G; Chaigneau, J; Eddine Charaf, M

    2012-02-01

    We evaluated whether quantitative measurements of liver fibrosis with recently developed diagnostics outperform histological staging in detecting natural or interferon-induced changes. We compared Metavir staging, morphometry (area and fractal dimension) and six blood tests in 157 patients with chronic hepatitis C from two trials testing maintenance interferon for 96 weeks. Paired liver biopsies and blood tests were available for 101 patients, and there was a significant improvement in Metavir activity and a significant increase in blood tests reflecting fibrosis quantity in patients treated with interferon when compared with controls - all per cent changes in histological fibrosis measures were significantly increased in F1 vs F2-4 stages only in the interferon group. For the whole population studied between weeks 0 and 96, there was significant progression only in the area of fibrosis (AOF) (P = 0.026), FibroMeter (P = 0.020) and CirrhoMeter (P = 0.003). With regards to dynamic reproducibility, agreement was good (r(ic) ≥ 0.72) only for Metavir fibrosis score, FibroMeter and CirrhoMeter. The per cent change in AOF was significantly higher than that of fractal dimension (P = 0.003) or Metavir fibrosis score (P = 0.015). CirrhoMeter was the only blood test with a change significantly higher than that of AOF (P = 0.039). AOF and two blood tests, reflecting fibrosis quantity, have high sensitivity and/or reproducibility permitting the detection of a small progression in liver fibrosis over two years. A blood test reflecting fibrosis quantity is more sensitive and reproducible than morphometry. The study also shows that maintenance interferon does not improve fibrosis, whatever its stage. © 2011 Blackwell Publishing Ltd.

  20. Breed, sex, and litter effects in 2-month old puppies' behaviour in a standardised open-field test.

    Science.gov (United States)

    Barnard, Shanis; Marshall-Pescini, Sarah; Pelosi, Annalisa; Passalacqua, Chiara; Prato-Previde, Emanuela; Valsecchi, Paola

    2017-05-11

    A considerable number of studies have reported differences among dog breeds with respect to their genetic profile, cognitive abilities or personality traits. Each dog breed is normally treated as a homogeneous group, however, researchers have recently questioned whether the behavioural profile of modern breeds still reflects their historical function or if the intense divergent selective pressures and geographical barriers have created a more fragmented picture. The majority of studies attempting to assess and compare modern breeds' personality focused on the evaluation of adult dogs where the potential effects of environmental/human factors on the dogs' behaviour are hard to discern from their genetic heritage. In the following study, we aimed at investigating between- and within-breed differences in the personality of two-months-old puppies by direct behavioural observation of 377 puppies from 12 breeds. Results showed that there was no effect of sex, however both breed and litter, significantly affected all personality traits. Breed on average explained 10% of the variance, whereas the effect of litter was noticeably higher, explaining on average 23% of the variance. Taken together, our results suggest that breed does have some influence on personality traits, but they also highlight the importance of taking litter effects into account.

  1. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    Science.gov (United States)

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  2. A novel approach to detect test-seeking behaviour in the blood donor population: making the invisible visible.

    Science.gov (United States)

    de Vos, A S; Lieshout-Krikke, R W; Slot, E; Cator, E A; Janssen, M P

    2016-10-01

    Individuals may donate blood in order to determine their infection status after exposure to an increased infection risk. Such test-seeking behaviour decreases transfusion safety. Instances of test seeking are difficult to substantiate as donors are unlikely to admit to such behaviour. However, manifestation in a population of repeat donors may be determined using statistical inference. Test-seeking donors would be highly motivated to donate following infection risk, influencing the timing of their donation. Donation intervals within 2005-2014 of all Dutch blood donors who acquired syphilis (N = 50), HIV (N = 13), HTLV (N = 4) or HCV (N = 2) were compared to donation intervals of uninfected blood donors (N = 7 327 836) using the Anderson-Darling test. We adjusted for length bias as well as for age, gender and donation type of the infected. Additionally, the power of the proposed method was investigated by simulation. Among the Dutch donors who acquired infection, we found only a non-significant overrepresentation of short donation intervals (P = 0·54). However, we show by simulation that both relatively short and long donation intervals among infected donors can reveal test seeking. The power of the method is >90% if among 69 infected donors >35 (51%) are test seeking, or if among 320 infected donors >90 (30%) are test seeking. We show how statistical analysis may be used to reveal the extent of test seeking in repeat blood donor populations. In the Dutch setting, indications for test-seeking behaviour were not statistically significant. This may, however, be due to the low number of infected individuals. © 2016 International Society of Blood Transfusion.

  3. Susceptibility Testing

    Science.gov (United States)

    ... Marker Bicarbonate (Total CO2) Bilirubin Blood Culture Blood Gases Blood Ketones Blood Smear Blood Typing Blood Urea ... hours depending on the method used. There are commercial tests available that offer rapid susceptibility testing and ...

  4. Early diagnosis of HIV in children below 18 months using DNA PCR test--assessment of the effectiveness of PMTCT interventions and challenges in early initiation of ART in a resource-limited setting.

    Science.gov (United States)

    Gupta, Anil; Singh, Girraj; Kaushik, Pratap; Joshi, Bipin; Kalra, Kamlesh; Chakraborty, Sabyasachi

    2013-04-01

    This study was conducted to assess efficacy of the current Indian Prevention of Mother-to-Child Transmission (PMTCT) protocol in 217 HIV-exposed infants, and to assess challenges in the early initiation of antiretroviral treatment (ART) in 18 (8.3%) infants with HIV, as determined by the HIV-1 DNA polymerase chain reaction (PCR) test at ≥ 6 weeks to ART was initiated in 10 (55.6%) HIV-infected children at a mean ± standard deviation (SD) age of 10.45 ± 4.9 (range: 4-17.5) months; delay resulted in opportunistic infections in one-third of the children. A single-dose nevirapine PMTCT regimen should be replaced by a triple antiretroviral regimen; DBS DNA PCR-positive infants may be given ART, and simultaneously a whole blood specimen should be taken to determine whether ART should be continued.

  5. Blood tests in tired elite athletes: expectations of athletes, coaches and sport science/sports medicine staff

    Science.gov (United States)

    Fallon, K E

    2007-01-01

    Background The issue of the expectations of elite athletes, their coaches and non‐medically qualified athlete support staff of consultations with sports physicians has not been previously dealt with in the sports medicine literature. As fulfilment of expectations of the content of a consultation may influence patient's satisfaction and clinical outcome, it is important to assess the expectations of athletes and, most importantly, coaches. Objective To assess the expectations and beliefs about fatigue, particularly in relation to blood tests, of athletes, their coaches and support staff in the specific context of tiredness of sports science or non‐medically qualified sports medicine staff, 22 elite coaches and 62 elite athletes from the Australian Institute of Sport were included in this study. Methods A single questionnaire. Results The expectation for a blood test at the initial consultation for short‐term fatigue was particularly high among athletes (81%) and coaches (91%). This expectation increased in athletes if their performance was worsening. All groups unanimously suggested that a blood test be performed in cases of more prolonged fatigue. Increase in total training load was perceived to be the most important cause of fatigue, but issues relating to sleep were also thought to be highly relevant. All groups suggested that blood tests provide some degree of reassurance, and all groups suggested that the most important blood tests that might be performed related to exclusion of iron deficiency, anaemia and infection. Conclusion Athletes and their coaches generally expect that blood tests will be performed even when fatigue has been present for performed. PMID:17062653

  6. Performance of rapid diagnostic test, blood-film microscopy and PCR for the diagnosis of malaria infection among febrile children from Korogwe District, Tanzania

    DEFF Research Database (Denmark)

    Mahende, Coline; Ngasala, Billy; Lusingu, John

    2016-01-01

    with fever and/or history of fever in the previous 48 h attending outpatient clinics. Blood samples were collected for identification of Plasmodium falciparum infection using histidine-rich-protein-2 (HRP-2)-based malaria RDT, light microscopy and conventional PCR. Results: A total of 867 febrile patients......Background: Rapid diagnostic tests (RDT) and light microscopy are still recommended for diagnosis to guide the clinical management of malaria despite difficult challenges in rural settings. The performance of these tests may be affected by several factors, including malaria prevalence and intensity...... of transmission. The study evaluated the diagnostic performance of malaria RDT, light microscopy and polymerase chain reaction (PCR) in detecting malaria infections among febrile children at outpatient clinic in Korogwe District, northeastern Tanzania. Methods: The study enrolled children aged 2-59 months...

  7. Brain blood-flow changes during motion sickness. [thalamus vascular changes in dogs during swing tests

    Science.gov (United States)

    Johnson, W. H.; Hsuen, J.

    1973-01-01

    The possibility of diminished blood flow in the brain is studied as one of the factors resulting from an increase in skeletal muscle blood volume concomitant with other characteristics of motion sickness. Thermistors are implanted in the thalamus of dogs and blood flow changes are recorded while they are subjected to sinusoidal movement on a two pole swing. Results of these initial steps in a proposed long term exploration of different areas of the brain are presented.

  8. Comparison of the population excess fraction of Chlamydia trachomatis infection on pelvic inflammatory disease at 12-months in the presence and absence of Chlamydia testing and treatment

    DEFF Research Database (Denmark)

    Davies, Bethan; Turner, Katy M.E.; Leung, Stella

    2017-01-01

    Background: The impact of Chlamydia trachomatis (chlamydia) control on the incidence of pelvic inflammatory disease (PID) is theoretically limited by the proportion of PID caused by chlamydia. We estimate the population excess fraction (PEF) of treated chlamydia infection on PID at 12-months...... in settings with widespread chlamydia control (testing and treatment) and compare this to the estimated PEF of untreated chlamydia. Methods: We used two large retrospective population-based cohorts of women of reproductive age from settings with widespread chlamydia control to calculate the PEF of treated...... chlamydia on PID at 12-months. We undertook a systematic review to identify further studies that reported the risk of PID in women who were tested for chlamydia (infected and uninfected). We used the same method to calculate the PEF in eligible studies then compared all estimates of PEF. Results...

  9. The Effects of Teacher and Teacher-librarian High-end Collaboration on Inquiry-based Project Reports and School Monthly Test Scores of Fifth-grade Students

    OpenAIRE

    Hai-Hon Chen

    2015-01-01

    The purpose of this study was twofold. The first purpose was to establish the high level collaboration of integrated instruction model between social studies teacher and teacher-librarian. The second purpose was to investigate the effects of high-end collaboration on the individual and groups’ inquiry-based project reports, as well as monthly test scores of fifth-grade students. A quasi-experimental method was adopted, two classes of elementary school fifth graders in Tainan Municipal city, T...

  10. Agreement of the Kato-Katz test established by the WHO with samples fixed with sodium acetate analyzed at 6 months to diagnose intestinal geohelminthes.

    Science.gov (United States)

    Alfredo Fernández-Niño, Julián; David Ramírez, Juan; Consuelo López, Myriam; Inés Moncada, Ligia; Reyes, Patricia; Darío Heredia, Rubén

    2015-06-01

    The aim of this study was to evaluate the performance of the Kato-Katz test (WHO version) with stool samples from a rural area, fixed with sodium acetate (SAF). The Kato-Katz test was used to compare unfixed samples (conventional test) with the same samples containing SAF fixative at time 0 and at 6 months. The study included stools from 154 subjects. A marginally statistically significant decrease in prevalence was estimated only for hookworm, when comparing unfixed samples versus the SAF fixed samples read at 6 months (p=0.06). A significant reduction in parasite load was found for hookworm (p<0.01) and Trichuris trichiura (p<0.01) between the unfixed and the fixed sample read at 6 months, but not for Ascaris lumbricoides (p=0.10). This research suggests that the SAF fixative solution is a good option for transporting samples for diagnosis, especially in rural areas in developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Identification of lung cancer with high sensitivity and specificity by blood testing

    Directory of Open Access Journals (Sweden)

    Stephan Bernhard

    2010-02-01

    Full Text Available Abstract Background Lung cancer is a very frequent and lethal tumor with an identifiable risk population. Cytological analysis and chest X-ray failed to reduce mortality, and CT screenings are still controversially discussed. Recent studies provided first evidence for the potential usefulness of autoantigens as markers for lung cancer. Methods We used extended panels of arrayed antigens and determined autoantibody signatures of sera from patients with different kinds of lung cancer, different common non-tumor lung pathologies, and controls without any lung disease by a newly developed computer aided image analysis procedure. The resulting signatures were classified using linear kernel Support Vector Machines and 10-fold cross-validation. Results The novel approach allowed for discriminating lung cancer patients from controls without any lung disease with a specificity of 97.0%, a sensitivity of 97.9%, and an accuracy of 97.6%. The classification of stage IA/IB tumors and controls yielded a specificity of 97.6%, a sensitivity of 75.9%, and an accuracy of 92.9%. The discrimination of lung cancer patients from patients with non-tumor lung pathologies reached an accuracy of 88.5%. Conclusion We were able to separate lung cancer patients from subjects without any lung disease with high accuracy. Furthermore, lung cancer patients could be seprated from patients with other non-tumor lung diseases. These results provide clear evidence that blood-based tests open new avenues for the early diagnosis of lung cancer.

  12. On the effect of dihydroergocristin-methansulfonate on human cerebral blood flow in an acute test

    International Nuclear Information System (INIS)

    Kohlmeyer, K.; Blessing, J.

    1978-01-01

    In 20 patients suffering from acute cerebrovascular diseases, cerebral trauma, cerebral atrophy and an apallic syndrome due to heart arrest, studies of regional cerebral blood flow (rCBF) were performed by means of the intracaroticial 133 xenon clearance method using 35 scintillation detectors to test the effect of dihydroegocristin-methansulfonate (DHEC) on the cerebral circulation. 0.6 mg and 0.9 mg, resp., DHEC dissolved in 200 mg levulose 5% were administered by a slow i.v. infusion during 20 min. Taking into consideration both the administered dosage of DHEC and the clinical diagnoses of the material, the results are the following: 0.6 mg DHEC lead to a significant increase of mean hemispheric flow in the average of 10 patients. On the other hand, 0.9 mg DHEC does not effect a significant change of mean hemispheric flow in the average of 10 patients. The highest increase of mean hemispheric flow was observed in the group of cases with cerebrovascular diseases receiving 0.6 mg DHEC. (orig./AJ) [de

  13. The characterization of NMR signal for blood pressure monitoring system and its testing

    Directory of Open Access Journals (Sweden)

    Bambang Murdaka Eka Jati

    2016-02-01

    Full Text Available ABSTRACT A blood monitoring system based on NMR method has been designed on constructed. This set-up of equipment used magnetic permanent, radio frequency (RF, receiver coil (RC, function generator (FG, amplifier which included the filter, as well as the oscilloscope digital storage. The background of this research was based on the sensitivity of NMR signal. The signal must be separated from signals background. This method was done by adjusting the frequency on FG, which was connected to radio frequency (RF coil, on empty sample. Subsequently, NMR signal was received by RC, and that signal could be shown on oscilloscope at resonance condition. The true frequency on NMR signal was Larmor frequency, and the other was background. The two variables of this experiment were the position of RF coil and the location temperature (20 up to 30oC. In conclusion, the resonance frequency of NMR signal (as Larmor frequency was 4.7 MHz (at static magnetic field of 1,600 gauss and it could be separated from background signals (3.4 and 6.2 MHz, and that signal was almost constant to room temperature. The equipment was used for sample testing. It gave systole/diastole data of 110/70 mmHg (on sphygmomanometer that was similar to 17/9 mV (on NMR signal. ABSTRAK Telah dikembangkan alat pemantauan tekanan darah berdasar prinsip NMR.

  14. Testing the effects of educational toilet posters: a novel way of reducing haemolysis of blood samples within ED.

    Science.gov (United States)

    Corkill, David

    2012-02-01

    Haemolysed blood samples are an unnecessary burden on Emergency Departments (ED) as they increase workloads and drive down efficiencies. Little empirical data exists that demonstrates the effectiveness of educational posters displayed in staff toilet cubicles. This study explored the impact educational toilet posters have on reducing haemolysis rates within the ED. A time series study of the clinical effect of educational toilet posters on reducing haemolysis rates throughout a 12 month period at the Gold Coast Hospital ED was undertaken. The GCH ED is a tertiary emergency service that has approximately 66,000 patient presentations per year. Data was collected prospectively. Analysis was undertaken to investigate the effects on total number of haemolysed samples and those clinically significant samples with a haemolytic index >3. Further investigation explored the specific effects on medical and nursing staff. Analysis undertaken using an independent t-test found that the pre-intervention data demonstrates a medium haemolysis rate of 4.92% (SD=1.04). This is a statistically significantly different (t=3.56, df=50, p=0.001) from the median post intervention data of 3.95% (SD=0.84). The difference of 0.97% (95%CI=0.42, 1.52) represents a 19.72% reduction in clinically significant haemolysed samples over the study period. This study reveals that the use of educational toilet posters had a positive impact on reducing the rates of haemolysed samples collected within the ED. This simple and cost effective educational initiative changed the behaviour of clinical staff. Further investigation is warranted to examine the impact of educational toilet posters on additional clinical scenarios. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  15. Routine Laboratory Blood Tests May Diagnose Significant Fibrosis in Liver Transplant Recipients with Chronic Hepatitis C: A 10 Year Experience.

    Science.gov (United States)

    Sheen, Victoria; Nguyen, Heajung; Jimenez, Melissa; Agopian, Vatche; Vangala, Sitaram; Elashoff, David; Saab, Sammy

    2016-03-28

    The aims of our study were to determine whether routine blood tests, the aspartate aminotransferase (AST) to Platelet Ratio Index (APRI) and Fibrosis 4 (Fib-4) scores, were associated with advanced fibrosis and to create a novel model in liver transplant recipients with chronic hepatitis C virus (HCV). We performed a cross sectional study of patients at The University of California at Los Angeles (UCLA) Medical Center who underwent liver transplantation for HCV. We used linear mixed effects models to analyze association between fibrosis severity and individual biochemical markers and mixed effects logistic regression to construct diagnostic models for advanced fibrosis (METAVIR F3-4). Cross-validation was used to estimate a receiving operator characteristic (ROC) curve for the prediction models and to estimate the area under the curve (AUC). The mean (± standard deviation [SD]) age of our cohort was 55 (±7.7) years, and almost three quarter were male. The mean (±SD) time from transplant to liver biopsy was 19.9 (±17.1) months. The mean (±SD) APRI and Fib-4 scores were 3 (±12) and 7 (±14), respectively. Increased fibrosis was associated with lower platelet count and alanine aminotransferase (ALT) values and higher total bilirubin and Fib-4 scores. We developed a model that takes into account age, gender, platelet count, ALT, and total bilirubin, and this model outperformed APRI and Fib-4 with an AUC of 0.68 (p fibrosis more reliably than APRI and Fib-4 scores. This noninvasive calculation may be used clinically to identify liver transplant recipients with HCV with significant liver damage.

  16. Study of the cross-reactivity of fish allergens based on a questionnaire and blood testing.

    Science.gov (United States)

    Kobayashi, Yukihiro; Huge, Jiletu; Imamura, Shintaro; Hamada-Sato, Naoko

    2016-07-01

    Parvalbumin and collagen have been identified as cross-reactive allergens for fish allergies. Although doctors realize that various fish elicit allergies, the targets of food allergen labeling laws were only mackerels and salmons in Japan and mackerels in South Korea. This study aimed to reveal the causative species for fish allergy via questionnaires and blood tests. Questionnaire research was conducted in Japan via the internet concerning allergies for fish-allergic patients or their family members. Next, IgE reactivities and cross-reactivities of 26 fish species were analyzed using sera obtained from 16 Japanese patients who were allergic to fish parvalbumin or collagen by enzyme-linked immunosorbent assay (ELISA) and inhibition ELISA. Questionnaire research revealed that 88% patients cannot eat mackerel and salmon in addition to other fish. In addition, 85% respondents were not satisfied with the current food allergen labeling law. In ELISA analyses, we clarified that pooled serum obtained from patients with fish parvalbumin-specific allergies exhibited IgE reactivity to the extracts of most fish species, and pooled serum obtained from patients with fish collagen-specific allergies displayed IgE reactivity to the extracts of all types of fish. Inhibition ELISA experiments revealed cross-reactivities of parvalbumin or collagen to extracts from all fish tested. Most patients with fish allergies displayed allergic symptoms following the intake of various fish species. In addition, fish parvalbumin and collagen were causative factors of fish allergy and were highly cross-reactive fish panallergens. Therefore, current laws should be revised in Japan and South Korea. Copyright © 2016 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.

  17. Screening for transfusion transmissible infections using rapid diagnostic tests in Africa: a potential hazard to blood safety?

    Science.gov (United States)

    Prugger, C.; Laperche, S.; Murphy, E. L.; Bloch, E. M.; Kaidarova, Z.; Tafflet, M.; Lefrère, J.-J.; Jouven, X.

    2016-01-01

    Rapid diagnostic tests (RDTs) are routinely used in African blood centres. We analysed data from two cross-sectional studies representing 95 blood centres in 29 African countries. Standardized panels of sera containing varying concentrations of anti-human immunodeficiency virus (HIV) antibodies (Ab), hepatitis B virus antigen (HBsAg) and antihepatitis C virus (HCV) Ab were screened using routine operational testing procedures at the centres. Sensitivity of detection using RDTs was high for HIV Ab-positive samples, but low for intermediately HBsAg (51·5%) and HCV Ab (40·6%)-positive samples. These findings suggest that current RDT use in Africa could pose a hazard to blood safety. PMID:26646317

  18. Evaluation of the Verigene Gram-positive blood culture nucleic acid test for rapid detection of bacteria and resistance determinants.

    Science.gov (United States)

    Wojewoda, Christina M; Sercia, Linda; Navas, Maria; Tuohy, Marion; Wilson, Deborah; Hall, Geraldine S; Procop, Gary W; Richter, Sandra S

    2013-07-01

    Rapid identification of pathogens from blood cultures can decrease lengths of stay and improve patient outcomes. We evaluated the accuracy of the Verigene Gram-positive blood culture (BC-GP) nucleic acid test for investigational use only (Nanosphere, Inc., Northbrook, IL) for the identification of Gram-positive bacteria from blood cultures. The detection of resistance genes (mecA in Staphylococcus aureus and Staphylococcus epidermidis and vanA or vanB in Enterococcus faecium and Enterococcus faecalis) by the BC-GP assay also was assessed. A total of 186 positive blood cultures (in BacT/Alert FA bottles) with Gram-positive cocci observed with Gram staining were analyzed using the BC-GP assay. The BC-GP results were compared with the identification and susceptibility profiles obtained with routine methods in the clinical laboratory. Discordant results were arbitrated with additional biochemical, cefoxitin disk, and repeat BC-GP testing. The initial BC-GP organism identification was concordant with routine method results for 94.6% of the blood cultures. Only 40% of the Streptococcus pneumoniae identifications were correct. The detection of the mecA gene for 69 blood cultures with only S. aureus or S. epidermidis was concordant with susceptibility testing results. For 3 of 6 cultures with multiple Staphylococcus spp., mecA detection was reported but was correlated with oxacillin resistance in a species other than S. aureus or S. epidermidis. The detection of vanA agreed with susceptibility testing results for 45 of 46 cultures with E. faecalis or E. faecium. Comparison of the mean times to results for each organism group showed that BC-GP results were available 31 to 42 h earlier than phenotypic identifications and 41 to 50 h earlier than susceptibility results.

  19. Daddy Months

    OpenAIRE

    Volker Meier; Helmut Rainer

    2014-01-01

    We consider a bargaining model in which husband and wife decide on the allocation of time and disposable income. Since her bargaining power would go down otherwise more strongly, the wife agrees to having a child only if the husband also leaves the labor market for a while. The daddy months subsidy enables the couple to overcome a hold-up problem and thereby improves efficiency. However, the same ruling harms cooperative couples and may also reduce welfare in an endogenous taxation framework.

  20. Ordering blood tests for patients with unexplained fatigue in general practice: what does it yield? Results of the VAMPIRE trial.

    NARCIS (Netherlands)

    Koch, H.; Bokhoven, M.A. van; Riet, G. ter; Alphen-Jager, J.T. van; Weijden, T.T. van der; Dinant, G.J.; Bindels, P.J.

    2009-01-01

    BACKGROUND: Unexplained fatigue is frequently encountered in general practice. Because of the low prior probability of underlying somatic pathology, the positive predictive value of abnormal (blood) test results is limited in such patients. AIM: The study objectives were to investigate the

  1. Ordering blood tests for patients with unexplained fatigue in general practice: what does it yield? Results of the VAMPIRE trial

    NARCIS (Netherlands)

    Koch, Hèlen; van Bokhoven, Marloes A.; ter Riet, Gerben; van Alphen-Jager, Jm Tineke; van der Weijden, Trudy; Dinant, Geert-Jan; Bindels, Patrick Je

    2009-01-01

    Background Unexplained fatigue is frequently encountered in general practice. Because of the low prior probability of underlying somatic pathology, the positive predictive value of abnormal (blood) test results is limited in such patients. Aim The study objectives were to investigate the

  2. Detection of colorectal cancer in symptomatic outpatients without visible rectal bleeding: Validity of the fecal occult blood test

    DEFF Research Database (Denmark)

    Bjerregaard, Niels Christian; Tøttrup, Anders; Sørensen, Henrik Toft

    2009-01-01

    In 2002, a new diagnostic strategy in symptomatic outpatients without known established colorectal cancer risk factors aged 40 years or older was implemented in Denmark. Fecal occult blood test (Hemoccult Sensa®) was a part of that strategy in patients without visible rectal bleeding....

  3. How to encourage non-donors to be more willing to donate blood? Testing of binding communication based interventions.

    Science.gov (United States)

    Fonte, D; Blondé, J; Girandola, F

    2017-06-01

    Our study aims to test the effectiveness of binding communication based interventions (vs classical persuasive communication based ones) inciting non-donors to act in favour of blood donation. The implementation of effective communication interventions represents a major public health issue. Nevertheless, persuasive media campaigns appear to have little effect on behaviours. Even though non-donors hold a positive attitude towards blood donation, they are not inclined to donate. As an alternative to producing behavioural changes, many recent studies have shown the superiority of binding communication over persuasive communication. All participants, non-donors, were randomly assigned to one of four experimental conditions of a 2 (type of communication: persuasive vs binding) × 2 (source credibility: low vs high) factorial design. Then, they were asked to report their intention to donate blood, and their intention to distribute leaflets regarding blood donation. Binding communication is a more effective strategy for increasing intention towards blood donation compared with persuasive communication, especially when combined with high credibility source. Accordingly this study calls for more consideration of knowledge of social psychology to design effective communication interventions and increase the number of donations. © 2016 British Blood Transfusion Society.

  4. Direct blood culturing on solid medium outperforms an automated continuously monitored broth-based blood culture system in terms of time to identification and susceptibility testing

    Directory of Open Access Journals (Sweden)

    E.A. Idelevich

    2016-03-01

    Full Text Available Pathogen identification and antimicrobial susceptibility testing (AST should be available as soon as possible for patients with bloodstream infections. We investigated whether a lysis-centrifugation (LC blood culture (BC method, combined with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS identification and Vitek 2 AST, provides a time advantage in comparison with the currently used automated broth-based BC system. Seven bacterial reference strains were added each to 10 mL human blood in final concentrations of 100, 10 and 1 CFU/mL. Inoculated blood was added to the Isolator 10 tube and centrifuged at 3000 g for 30 min, then 1.5 mL sediment was distributed onto five 150-mm agar plates. Growth was observed hourly and microcolonies were subjected to MALDI-TOF MS and Vitek 2 as soon as possible. For comparison, seeded blood was introduced into an aerobic BC bottle and incubated in the BACTEC 9240 automated BC system. For all species/concentration combinations except one, successful identification and Vitek 2 inoculation were achieved even before growth detection by BACTEC. The fastest identification and inoculation for AST were achieved with Escherichia coli in concentrations of 100 CFU/mL and 10 CFU/mL (after 7 h each, while BACTEC flagged respective samples positive after 9.5 h and 10 h. Use of the LC-BC method allows skipping of incubation in automated BC systems and, used in combination with rapid diagnostics from microcolonies, provides a considerable advantage in time to result. This suggests that the usefulness of direct BC on solid medium should be re-evaluated in the era of rapid microbiology.

  5. The Effects of Teacher and Teacher-librarian High-end Collaboration on Inquiry-based Project Reports and School Monthly Test Scores of Fifth-grade Students

    Directory of Open Access Journals (Sweden)

    Hai-Hon Chen

    2015-07-01

    Full Text Available The purpose of this study was twofold. The first purpose was to establish the high level collaboration of integrated instruction model between social studies teacher and teacher-librarian. The second purpose was to investigate the effects of high-end collaboration on the individual and groups’ inquiry-based project reports, as well as monthly test scores of fifth-grade students. A quasi-experimental method was adopted, two classes of elementary school fifth graders in Tainan Municipal city, Taiwan were used as samples. Students were randomly assigned to experimental conditions by class. Twenty eight students of the experimental group were taught by the collaboration of social studies teacher and teacher-librarian; while 27 students of the controlled group were taught separately by teacher in didactic teaching method. Inquiry-Based Project Record, Inquiry-Based Project Rubrics, and school monthly test scores were used as instruments for collecting data. A t-test and correlation were used to analyze the data. The results indicate that: (1 High-end collaboration model between social studies teacher and teacher-librarian was established and implemented well in the classroom. (2There was a significant difference between the experimental group and the controlled group in individual and groups’ inquiry-based project reports. Students that were taught by the collaborative teachers got both higher inquiry-based project reports’ scores than those that were taught separately by the teachers. Experimental group’s students got higher school monthly test scores than controlled groups. Suggestions for teachers’ high-end collaboration and future researcher are provided in this paper.

  6. Performance of a new meter designed for assisted monitoring of blood glucose and point-of-care testing.

    Science.gov (United States)

    Macrury, Sandra; Srinivasan, Aparna; Mahoney, John J

    2013-03-01

    Blood glucose (BG) meters used for assisted monitoring of blood glucose (AMBG) require different attributes compared with meters designed for home use. These include safety considerations (i.e., minimized risk of blood-borne pathogen transmission), capability for testing multiple blood sample types, and enhanced performance specifications. The OneTouch® Verio™Pro+ BG meter is designed to incorporate all of these attributes. Meter accuracy was assessed in clinical studies with arterial, venous, and capillary blood samples with a hematocrit range of 22.9-59.8%. The effect of interferents, including anticoagulants, on accuracy was evaluated. The meter disinfection protocol was validated, and instructions for use and user acceptance of the system were assessed. A total of 97% (549/566) of BG measures from all blood sample types and 95.5% (191/200) of arterial blood samples were within ±12 mg/dl or 12.5% of reference measurements. The system was unaffected by 4 anticoagulants and 57 of 59 endogenous and exogenous compounds; it was affected by 2 compounds: pralidoxime iodide and xylose. Bleach wipes were sufficient to disinfect the meter. Users felt that the meter's quality control (QC) prompts would help them to comply with regulatory requirements. The meter provided accurate measurements of different blood samples over a wide hematocrit range and was not affected by 57 physiologic and therapeutic compounds. The QC prompts and specific infection-mitigating design further aid to make this meter system practical for AMBG in care facilities. © 2013 Diabetes Technology Society.

  7. A comparative study of the typhidot (Dot-EIA) and Widal tests in blood culture positive cases of typhoid fever.

    Science.gov (United States)

    Khoharo, Haji Khan

    2011-07-01

    Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.

  8. Progress report, 24 months

    DEFF Research Database (Denmark)

    Juhl, Thomas Winther; Nielsen, Jakob Skov

    The work performed during the past 12 months (months 13 – 24) of the project has included the conclusion of Task 1 – Fundamental Studies and Task 2 – Multimirror Cutting Head Design. Work on Task 3 – Compact Cutting Head Design, and Task 4 – Interface Design has been carried out and the tests...... of the multimirror cutting head have been started....

  9. Progress report, 36 months

    DEFF Research Database (Denmark)

    Juhl, Thomas Winther; Nielsen, Jakob Skov

    The work performed during the past 12 months (months 13 – 24) of the project has included the conclusion of Task 1 – Fundamental Studies and Task 2 – Multimirror Cutting Head Design. Work on Task 3 – Compact Cutting Head Design, and Task 4 – Interface Design has been carried out and the tests...... of the multimirror cutting head have been started....

  10. Contributions of neuroimaging, balance testing, electrophysiology and blood markers to the assessment of sport-related concussion.

    Science.gov (United States)

    Davis, G A; Iverson, G L; Guskiewicz, K M; Ptito, A; Johnston, K M

    2009-05-01

    To review the diagnostic tests and investigations used in the management of sports concussion, in the adult and paediatric populations, to (a) monitor the severity of symptoms and deficits, (b) track recovery and (c) advance knowledge relating to the natural history and neurobiology of the injury. Qualitative literature review of the neuroimaging, balance testing, electrophysiology, blood marker and concussion literature. PubMed and Medline databases were reviewed for investigations used in the management of adult and paediatric concussion, including structural imaging (computerised tomography, magnetic resonance imaging, diffusion tensor imaging), functional imaging (single photon emission computerised tomography, positron emission tomography, functional magnetic resonance imaging), spectroscopy (magnetic resonance spectroscopy, near infrared spectroscopy), balance testing (Balance Error Scoring System, Sensory Organization Test, gait testing, virtual reality), electrophysiological tests (electroencephalography, evoked potentials, event related potentials, magnetoencephalography, heart rate variability), genetics (apolipoprotein E4, channelopathies) and blood markers (S100, neuron-specific enolase, cleaved Tau protein, glutamate). For the adult and paediatric populations, each test has been classified as being: (1) clinically useful, (2) a research tool only or (3) not useful in sports-related concussion. The current status of the diagnostic tests and investigations is analysed, and potential directions for future research are provided. Currently, all tests and investigations, with the exception of clinical balance testing, remain experimental. There is accumulating research, however, that shows promise for the future clinical application of functional magnetic resonance imaging in sport concussion assessment and management.

  11. Cytology and Human Papillomavirus Testing 6 to 12 Months after ASCUS or LSIL Cytology in Organized Screening To Predict High-Grade Cervical Neoplasia between Screening Rounds

    Science.gov (United States)

    Sjøborg, Katrine D.; Nygård, Mari; Røysland, Kjetil; Campbell, Suzanne; Alfsen, G. Cecilie; Jonassen, Christine M.

    2012-01-01

    We carried out a prospective study comparing the performance of human papillomavirus (HPV) E6/E7 mRNA (PreTect HPV-Proofer; NorChip, Klokkarstua, Norway) and DNA (Amplicor HPV test; Roche Diagnostics, Basel, Switzerland) triage testing of women 6 to 12 months after atypical-squamous-cells-of-undetermined-significance (ASCUS) or low-grade-squamous-intraepithelial-lesion (LSIL) cytology in organized screening to predict high-grade cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) between screening rounds. Between January 2005 and April 2008, 692 study women with screening-detected ASCUS/LSIL cytology 6 to 12 months earlier returned for HPV mRNA and DNA testing and repeat cytology. The median follow-up time was 3 years, using existing health care facilities. Follow-up test results were available for 625 women. Of the 145 CIN2+ cases detected during the study period, 95 (65.5%) were HPV mRNA positive 6 to 12 months after screening-detected ASCUS/LSIL, 44 (30.4%) were HPV mRNA negative, and 6 (4.1%) were invalid. The corresponding HPV DNA results were 139 (95.9%), 5 (3.4%), and 1 (0.7%), respectively. The cumulative incidences of CIN2+ 3 years after a negative HPV mRNA and DNA test were 10.3% (95% confidence interval [CI], 7.2 to 13.3%) and 1.8% (95% CI, 0.0 to 3.6%), respectively. The cumulative incidences of CIN2+ 3 years after positive HPV mRNA and DNA tests were 52.8% (95% CI, 40.1 to 60.1%) and 41.3% (95% CI, 35.5 to 46.6%), respectively. In conclusion, both positive HPV mRNA and DNA test results have a high enough long-term prediction of CIN2+ risk to consider referral to colposcopy as good practice when performed in delayed triage of women with ASCUS/LSIL cytology. In addition, the low CIN2+ risk among women with a negative Amplicor HPV test in our study confirms its safe use in a clinical setting. PMID:22518869

  12. Test for antioxidant ability by scavenging long-lived mutagenic radicals in mammalian cells and by blood test with intentional radicals: an application of gallic acid

    International Nuclear Information System (INIS)

    Kumagai, Jun; Kawaura, Tomoko; Miyazaki, Tetsuo; Prost, Michel; Prost, Emmanuelle; Watanabe, Masami; Quetin-Leclercq, J.Joeelle

    2003-01-01

    Antioxidant ability of gallic acid (GA) are determined both by electron spin resonance measurement of long-lived radicals produced in γ-ray irradiated Syrian golden hamster embryo cells with GA and by hemolysis measurement with GA when blood cells are submitted to radicals. Scavenging properties of GA are determined by the reaction rate constant with long-lived mutagenic radicals in the cells while the blood test allows to analyze the global effects of this compound: radical scavenger+metal ion chelator+regeneration of intra- and extra-cellular antioxidant

  13. Comprehensive Metabolomic Analysis in Blood, Urine, Fat, and Muscle in Men with Metabolic Syndrome: A Randomized, Placebo-Controlled Clinical Trial on the Effects of Resveratrol after Four Months' Treatment.

    Science.gov (United States)

    Korsholm, Anne Sofie; Kjær, Thomas Nordstrøm; Ornstrup, Marie Juul; Pedersen, Steen Bønløkke

    2017-03-04

    Resveratrol possesses several beneficial metabolic effects in rodents, while the effects of resveratrol in humans remain unclear. Therefore, we performed a non-targeted comprehensive metabolomic analysis on blood, urine, adipose tissue, and skeletal muscle tissue in middle-aged men with metabolic syndrome randomized to either resveratrol or placebo treatment for four months. Changes in steroid hormones across all four matrices were the most pronounced changes observed. Resveratrol treatment reduced sulfated androgen precursors in blood, adipose tissue, and muscle tissue, and increased these metabolites in urine. Furthermore, markers of muscle turnover were increased and lipid metabolism was affected, with increased intracellular glycerol and accumulation of long-chain saturated, monounsaturated, and polyunsaturated (n3 and n6) free fatty acids in resveratrol-treated men. Finally, urinary derivatives of aromatic amino acids, which mainly reflect the composition of the gut microbiota, were altered upon resveratrol treatment. In conclusion, the non-targeted metabolomics approach applied to four different matrices provided evidence of subtle but robust effects on several metabolic pathways following resveratrol treatment for four months in men with metabolic syndrome-effects that, for the most part, would not have been detected by routine analyses. The affected pathways should be the focus of future clinical trials on resveratrol's effects, and perhaps particularly the areas of steroid metabolism and the gut microbiome.

  14. the reliability of sickling and solubility tests and peripheral blood film

    African Journals Online (AJOL)

    Clinics in Mother and Child Health Vol 7, N°1, June 2010. THE RELIABILITY OF ... PERIPHERAL BLOOD FILM METHOD FOR SICKLE CELL DISEASE. SCREENING AT .... used in Jamaica as a confirmatory procedure [4], its use in most of the.

  15. Blood alcohol concentration testing and reporting by the states : traffic tech.

    Science.gov (United States)

    2012-08-01

    Accurate and complete data on blood alcohol concentration : (BAC) levels for drivers in fatal crashes are critical in monitoring : alcohol-impaired-driving rates across the country, developing : alcohol-impaired-driving programs, and evaluating : the...

  16. Low transfusion transmission of hepatitis E among 25,637 single-donation, nucleic acid-tested blood donors

    DEFF Research Database (Denmark)

    Harritshøj, Lene H.; Holm, Dorte K.; Sækmose, Susanne G.

    2016-01-01

    nucleic acid test with a 95% detection probability of 7.9 IU/mL. HEV-positive samples were quantified by real-time polymerase chain reaction and genotyped. Transmission was evaluated among recipients of HEV RNA-positive blood components. Phylogenetic analyses compared HEV sequences from blood donors......, symptomatic patients, and swine. RESULTS: Eleven donations (0.04%) were confirmed as positive for HEV RNA (median HEV RNA level, 13 IU/mL). Two donations were successfully genotyped as HEV-gt-3. Only one donor had a travel history outside Europe. Nine of 11 donors were male, but the gender ratio...

  17. Changes in blood glucose and insulin responses to intravenous glucose tolerance tests and blood biochemical values in adult female Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-02-01

    The metabolic mechanisms to circannual changes in body mass of bears have yet to be elucidated. We hypothesized that the Japanese black bear (Ursus thibetanus japonicus) has a metabolic mechanism that efficiently converts carbohydrates into body fat by altering insulin sensitivity during the hyperphagic stage before hibernation. To test this hypothesis, we investigated the changes in blood biochemical values and glucose and insulin responses to intravenous glucose tolerance tests (IVGTT) during the active season (August, early and late November). Four, adult, female bears (5-17 years old) were anesthetized with 6 mg/kg TZ (tiletamine HCl and zolazepam HCl) in combination with 0.1 mg/kg acepromazine maleate. The bears were injected intravenously with glucose (0.5 g/kg of body mass), and blood samples were obtained before, at, and intermittently after glucose injection. The basal triglycerides concentration decreased significantly with increase in body mass from August to November. Basal levels of plasma glucose and serum insulin concentrations were not significantly different among groups. The results of IVGTT demonstrated the increased peripheral insulin sensitivity and glucose tolerance in early November. In contrast, peripheral insulin resistance was indicated by the exaggerated insulin response in late November. Our findings suggest that bears shift their glucose and lipid metabolism from the stage of normal activity to the hyperphagic stage in which they show lipogenic-predominant metabolism and accelerate glucose uptake by increasing the peripheral insulin sensitivity.

  18. A comparative study of Widal test with blood culture in the diagnosis of typhoid fever in febrile patients.

    Science.gov (United States)

    Andualem, Gizachew; Abebe, Tamrat; Kebede, Nigatu; Gebre-Selassie, Solomon; Mihret, Adane; Alemayehu, Haile

    2014-09-17

    Typhoid fever is a major health problem in developing countries and its diagnosis on clinical ground is difficult. Diagnosis in developing countries including Ethiopia is mostly done by Widal test. However, the value of the test has been debated. Hence, evaluating the result of this test is necessary for correct interpretation of the result. The main aim of this study was to compare the result of Widal test and blood culture in the diagnosis of typhoid fever in febrile patients. Blood samples were collected from 270 febrile patients with symptoms clinically similar to typhoid fever and visiting St. Paul's General Specialized Hospitals from mid December 2010 to March 2011. Blood culture was used to isolate S.typhi and S.paratyphi. Slide agglutination test and tube agglutination tests were used for the determination of antibody titer. An antibody titer of ≥1:80 for anti TO and ≥1:160 for anti TH were taken as a cut of value to indicate recent infection of typhoid fever. One hundred and eighty six (68.9%) participants were females and eighty four (31.1%) were males. 7 (2.6%) cases of S. typhi and 4 (1.5%) cases of S. paratyphi were identified with the total prevalence of typhoid fever 4.1%. The total number of patients who have indicative of recent infection by either of O and H antigens Widal test is 88 (32.6%). The sensitivity, specificity, Positive predictive Value and Negative predictive Value of Widal test were 71.4%, 68.44%, 5.7% and 98.9% respectively. Widal test has a low sensitivity, specificity and PPV, but it has good NPV which indicates that negative Widal test result have a good indication for the absence of the disease.

  19. Babesia microti real-time polymerase chain reaction testing of Connecticut blood donors: potential implications for screening algorithms.

    Science.gov (United States)

    Johnson, Stephanie T; Van Tassell, Eric R; Tonnetti, Laura; Cable, Ritchard G; Berardi, Victor P; Leiby, David A

    2013-11-01

    Babesia microti, an intraerythrocytic parasite, has been implicated in transfusion transmission. B. microti seroprevalence in Connecticut (CT) blood donors is approximately 1%; however, it is not known what percentage of donors is parasitemic and poses a risk for transmitting infection. Therefore, we determined the prevalence of demonstrable B. microti DNA in donors from a highly endemic area of CT and compared observed rates with concurrent immunofluorescence assay (IFA) testing results. Blood samples from consenting donors in southeastern CT were collected from mid-August through early October 2009 and tested by IFA for immunoglobulin G antibodies and real-time polymerase chain reaction (PCR) for B. microti DNA. IFA specificity was determined using blood donor samples collected in northwestern Vermont (VT), an area nonendemic for Babesia. Of 1002 CT donors, 25 (2.5%) were IFA positive and three (0.3%) were real-time PCR positive. Among the three real-time PCR-positive donors, two were also IFA positive, while one was IFA negative and may represent a window period infection. The two IFA- and real-time PCR-positive donors appeared to subsequently clear infection. The other real-time PCR-positive donor did not provide follow-up samples. Of 1015 VT donors tested by IFA, only one (0.1%) was positive, but may have acquired infection during travel to an endemic area. We prospectively identified several real-time PCR-positive blood donors, including an IFA-negative real-time PCR-positive donor, in an area highly endemic for B. microti. These results suggest the need to include nucleic acid testing in planned mitigation strategies for B. microti. © 2013 American Association of Blood Banks.

  20. Use of an Interferon Gamma Release Assay (IGRA) to test T-cell responsiveness to soluble Leishmania infantum antigen in whole blood of dogs from endemic areas.

    Science.gov (United States)

    Zribi, Lilia; El-Goulli, Amel F; Ben-Abid, Meriem; Gharbi, Mohamed; Ben-Sghaier, Ines; Boufaden, Imed; Aoun, Karim; Bouratbine, Aïda

    2017-11-15

    Interferon-Gamma (IFN-γ) Release Assays (IGRAs) are easy tests that allow rapid screening of primed memory T-cells immunity in response to antigen. The aim of this study was to use IGRA to assess IFN-γ release in response to Soluble Leishmania infantum antigen (SLA) in whole blood of dogs living in endemic area of visceral leishmaniasis and to interpret IGRA results according to clinical examination, specific anti-Leishmania humoral response and presence of L. infantum DNA in blood. The study was carried out on 56 dogs living in greater Tunis area. Physical examination, quantitative serology and PCR on blood were used to characterize dogs' status in relation to Leishmania infection and disease. IGRA consisted on testing by ELISA for IFN-γ-secretion in whole blood after a 20-h challenge with SLA. PBS and Phytohemagglutinin (PHA) stimulations were used as controls. Four groups of dogs were characterized: 31 were negative by both serology and PCR, two had doubtful serology, 10 presented no to mild clinical signs but low antibodies levels and 13 were affected by Canine Leishmaniasis (CanL). In seronegative dogs, IGRA was little contributory in 4 puppies (age dogs (median age=72months, IQR: 45-84 months) that didn't respond to PHA stimulation, IGRA was negative in 19 and positive in three animals with lymph node enlargement. In dogs with doubtful serology, IGRA was positive in one dog and negative in the other. In infected dogs with no to mild clinical signs, one dog exhibited high level of IFN-γ in absence of antigenic stimulation and all the other were positive by IGRA. CanL dogs showed variable IGRA results. Negative IGRAs (n=4) were shown in animals with the highest parasitic burden whereas positive IGRAs (n=5) were shown in dogs with negative PCR or low parasitic load. The 4 remaining dogs either didn't respond to PHA (n=2) or showed non-specific secretion in PBS tube (n=2). The results of this study showed that IGRA is a useful new tool that can assess

  1. Half a decade of mini-pool nucleic acid testing: Cost-effective way for improving blood safety in India

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Background and Objectives: It is well established that Nucleic acid testing (NAT reduces window phase of transfusion transmissible infections (TTI and helps improve blood safety. NAT testing can be done individually or in pools. The objectives of this study were to determine the utility, feasibility and cost effectiveness of an in-house minipool-NAT(MP-NAT. Materials and Methods: Blood donors were screened by history, tested by ELISA and sero-negative samples were subjected to an in-house NAT by using reverse transcriptase-polymerase chain reaction (RT-PCR. Testing was done in mini-pools of size eight (8. Positive pools were repeated with individual samples. Results: During the study period of Oct 2005-Sept 2010 (5 years all blood donors (n=53729 were screened by ELISA. Of which 469 (0.87% were positive for HIV-1, HBV or HCV. Sero-negative samples (n=53260 were screened by in-house MP-NAT. HIV-NAT yield was 1/53260 (n=1 and HBV NAT yield (n=2 was 1/26630. Conclusion: NAT yield was lower than other India studies possibly due to the lower sero-reactivity amongst our donors. Nevertheless it intercepted 9 lives including the components prepared. The in-house assay met our objective of improving blood safety at nominal cost and showed that it is feasible to set up small molecular biology units in medium-large sized blood banks and deliver blood within 24-48 hours. The utility of NAT (NAT yield will vary based on the donor population, the type of serological test used, the nature of kit employed and the sensitivity of NAT test used. The limitations of our in-house MP-NAT consisted of stringent sample preparation requirements, with labor and time involved. The benefits of our MP-NAT were that it acted as a second level of check for ELISA tests, was relatively inexpensive compared to ID-NAT and did not need sophisticated equipment.

  2. Variability of plasma homovanillic acid over 13 months in patients with schizophrenia; relationship with the clinical response and the Wisconsin card sort test.

    Science.gov (United States)

    Zumárraga, Mercedes; González-Torres, Miguel A; Arrue, Aurora; Dávila, Ricardo; Dávila, Wendy; Inchausti, Lucía; Pérez-Cabeza, Lucía; Fernández-Rivas, Aránzazu; Bustamante, Sonia; Basterreche, Nieves; Guimón, José

    2011-08-01

    In the present study we have measured, on a monthly basis, the concentration of plasma homovanillic acid (pHVA) in schizophrenic patients during 13 months of their pharmacological treatment. The average pHVA values of each patient were within the range of 7.30-17.70 ng/ml and the coefficients of variation for each patient (CV %) were within the range of 13-33%. Half of the patients that showed higher pHVA CV% values also showed higher scores on the Brief Psychiatric Rating Scale at the beginning of the study, and improved more after 6 months, when compared to the remaining 50% with lower CV% values. There was no significant relationship between the scores of the Wisconsin Card Sort Test and the concentration or the CV% of the pHVA of each patient. A greater variability in the pHVA may be associated with a greater plasticity of the dopaminergic system and a better clinical response.

  3. Occult blood test and colonoscopy in the diagnosis of colorectal cancer; Test de sangre oculta y colonoscopia en el diagnostico del cancer colorrectal

    Energy Technology Data Exchange (ETDEWEB)

    Tusen Toledo, Yunia; Chao Gonzalez, Lissette; Barroso Marquez, Lisset [Centro Investigaciones Medicoquirurgicas (CIMEQ), La Habana (Cuba)

    2009-07-01

    A descriptive-prospective study was conducted on 212 outpatients from the Gastroenterology Service at CIMEQ's Hospital from January 2006- May 2007. These patients received an immune-chemical test of hidden blood in fecal stools and an endoscopic colon study, with the objective of determining the value of the hidden blood and colonoscopy for the detection of colorrectal cancer. Age average was 60, 6 {+-} 14,0 years, with predominance of the female sex. The main clinical condition for this study was to observe the change of intestinal habits in a 28, 3 % of patients, The test performed on hidden blood was positive in 76 patients (36,0%) and 34 (16,0%) had positive colorrectal cancer diagnosis, of which a 50% was localized at the proximal colon; 91,12% of the neoplasias were of the adenocarcinoma-type, where moderately differentiated ones predominated. A sensitiveness of a 76, 47 % and of a 71,91 % specificity were obtained when evaluating the efficacy of hidden blood in the diagnosis of neoplasias

  4. Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results.

    Science.gov (United States)

    Iwersen, M; Klein-Jöbstl, D; Pichler, M; Roland, L; Fidlschuster, B; Schwendenwein, I; Drillich, M

    2013-01-01

    The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring β-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement

  5. STS-42 MS Readdy conducts blood volume test on OV-103's middeck

    Science.gov (United States)

    1992-01-01

    STS-42 Mission Specialist (MS) William F. Readdy, using intravehicular activity (IVA) foot restraints, studies a checklist as he measures the veins in his lower right leg on the middeck of Discovery, Orbiter Vehicle (OV) 103. Readdy uses an electronic monitor and a pair of large blood pressure cuffs that encircle the thigh and calf. Changes in blood volume are determined by inflating the cuffs which then alters the blood pressure. The tone of the veins was monitored before and during the flight and will be measured following the eight-day mission. Behind Readdy are the forward lockers with combuster analyzer, checklists, communications kit assemblies, and spotmeter attached. At Readdy's left is the sleep station along the starboard wall.

  6. Activity test of various mangosteen (Garcinia mangostana pericarp extract fractions to decrease fasting blood cholesterol levels and lipid peroxidation activity in diabetic mice

    Directory of Open Access Journals (Sweden)

    Saikhu Akhmad Husen

    2017-01-01

    Full Text Available The objectives of this study were to determine the effect of various fractions of mangosteen (Garcinia mangostana pericarp extract to the changes of the fasting blood cholesterol and serum malondialdehyde (MDA levels on diabetic mice (Mus musculus. Thirty 3-4 months old male mice strain BALB/c, weight 20-30 g were divided into six groups. The first group was KN as a non diabetic control group, KD as a diabetic control, KM as a group of diabetic mice treated with metformin, and NP, SP, and P as the treatment groups that were treated by using three different fractions from mangosteen pericarp extract, non polar, semi polar, and polar respectively. The induction of Diabetes mellitus was done by the injection of STZ, and the mice were given a high fat diet treatment to induce the hiperlipidemia condition using lard for three weeks. The blood cholesterol levels were measured in all groups before and after the injection of lard, and day 1, 7, and 14 of treatment as well. The serum MDA level as the indicator of lipid peroxidation were measured by using QuantiChrom TBARS Assay Kit (DTBA-100. The data of cholesterol levels were statistically analyzed by t-test, while the data of serum MDA levels were analyzed by variance analysis followed by Duncan test. The results showed that the polar fraction of mangosteen pericarp had effect to decrease the fasting blood cholesterol level in mice, however the non polar and semi polar fraction had no simmilar effect. All of the fractions has shown significant effect to decrease the serum MDA level in mice. Key words: cholesterol, diabetes mellitus, Garcinia mangostana, malondialdehyde (mda, obesity.

  7. Noninvasive regional cerebral blood flow measurements at pre- and post-acetazolamide test using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Nakano, Seigo; Tanaka, Masaaki.

    1996-01-01

    A technique for serial noninvasive cerebral blood flow measurements at pre- and post-acetazolamide (Diamox) test was newly developed using 99m Tc-ECD without blood sampling. Baseline mean cerebral blood flow (mCBF) was measured from graphical analysis of time activity curves for brain and aortic arch obtained from radionuclide angiography by injection of 370-555 MBq 99m Tc-ECD. The first SPECT study was performed immediately after intravenous administration of 1 g of Diamox, then baseline regional cerebral blood flow (rCBF) was calculated using Lassen's correction algorithm. Immediately after the stop of the first SPECT study, additional 555-740 MBq of 99m Tc-ECD was administered, thereafter the second SPECT study was started. Post-Diamox SPECT images were obtained by subtraction of the first baseline images from the second images. Using Lassen's algorithm, post-Diamox mCBF was estimated from the baseline mCBF, the baseline mean SPECT counts, and post-Diamox mean SPECT counts corrected for administered dose and imaging time. Post-Diamox rCBF was obtained from the post-Diamox mCBF and the post-Diamox mean SPECT counts using Lassen's algorithm. Coefficient variation was shown 2.7% and 3.5%: mCBF and rCBF, respectively in test-retest results in six patients without Diamox administration. Nine demented patients without vascular disorders showed significant mCBF increase of 35.7% on the average by post-Diamox. In conclusion, this simplified method is practically useful for measuring CBF at pre- and post-Diamox test within short period of time without any blood sample. (author)

  8. Microbial identification and automated antibiotic susceptibility testing directly from positive blood cultures using MALDI-TOF MS and VITEK 2.

    Science.gov (United States)

    Wattal, C; Oberoi, J K

    2016-01-01

    The study addresses the utility of Matrix Assisted Laser Desorption/Ionisation Time-Of-Flight mass spectrometry (MALDI-TOF MS) using VITEK MS and the VITEK 2 antimicrobial susceptibility testing (AST) system for direct identification (ID) and timely AST from positive blood culture bottles using a lysis-filtration method (LFM). Between July and December 2014, a total of 140 non-duplicate mono-microbial blood cultures were processed. An aliquot of positive blood culture broth was incubated with lysis buffer before the bacteria were filtered and washed. Micro-organisms recovered from the filter were first identified using VITEK MS and its suspension was used for direct AST by VITEK 2 once the ID was known. Direct ID and AST results were compared with classical methods using solid growth. Out of the 140 bottles tested, VITEK MS resulted in 70.7 % correct identification to the genus and/ or species level. For the 103 bottles where identification was possible, there was agreement in 97 samples (94.17 %) with classical culture. Compared to the routine method, the direct AST resulted in category agreement in 860 (96.5 %) of 891 bacteria-antimicrobial agent combinations tested. The results of direct ID and AST were available 16.1 hours before those of the standard approach on average. The combined use of VITEK MS and VITEK 2 directly on samples from positive blood culture bottles using a LFM technique can result in rapid and reliable ID and AST results in blood stream infections to result in early institution of targeted treatment. The combination of LFM and AST using VITEK 2 was found to expedite AST more reliably.

  9. Combination of blood tests for significant fibrosis and cirrhosis improves the assessment of liver-prognosis in chronic hepatitis C.

    Science.gov (United States)

    Boursier, J; Brochard, C; Bertrais, S; Michalak, S; Gallois, Y; Fouchard-Hubert, I; Oberti, F; Rousselet, M-C; Calès, P

    2014-07-01

    Recent longitudinal studies have emphasised the prognostic value of noninvasive tests of liver fibrosis and cross-sectional studies have shown their combination significantly improves diagnostic accuracy. To compare the prognostic accuracy of six blood fibrosis tests and liver biopsy, and evaluate if test combination improves the liver-prognosis assessment in chronic hepatitis C (CHC). A total of 373 patients with compensated CHC, liver biopsy (Metavir F) and blood tests targeting fibrosis (APRI, FIB4, Fibrotest, Hepascore, FibroMeter) or cirrhosis (CirrhoMeter) were included. Significant liver-related events (SLRE) and liver-related deaths were recorded during follow-up (started the day of biopsy). During the median follow-up of 9.5 years (3508 person-years), 47 patients had a SLRE and 23 patients died from liver-related causes. For the prediction of first SLRE, most blood tests allowed higher prognostication than Metavir F [Harrell C-index: 0.811 (95% CI: 0.751-0.868)] with a significant increase for FIB4: 0.879 [0.832-0.919] (P = 0.002), FibroMeter: 0.870 [0.812-0.922] (P = 0.005) and APRI: 0.861 [0.813-0.902] (P = 0.039). Multivariate analysis identified FibroMeter, CirrhoMeter and sustained viral response as independent predictors of first SLRE. CirrhoMeter was the only independent predictor of liver-related death. The combination of FibroMeter and CirrhoMeter classifications into a new FM/CM classification improved the liver-prognosis assessment compared to Metavir F staging or single tests by identifying five subgroups of patients with significantly different prognoses. Some blood fibrosis tests are more accurate than liver biopsy for determining liver prognosis in CHC. A new combination of two complementary blood tests, one targeted for fibrosis and the other for cirrhosis, optimises assessment of liver-prognosis. © 2014 John Wiley & Sons Ltd.

  10. Direct identification and susceptibility testing of positive blood cultures using high speed cold centrifugation and Vitek II system.

    Science.gov (United States)

    Bazzi, Ali M; Rabaan, Ali A; Fawarah, Mahmoud M; Al-Tawfiq, Jaffar A

    Compared to routine isolated colony-based methods, direct testing of bacterial pellets from positive blood cultures reduces turnaround time for reporting of antibiotic susceptibility. The aim of this study was to compare the accuracy, and precision, of a rapid method for direct identification and susceptibility testing of blood cultures with the routine method used in our laboratory, using Vitek 2. A total of 60 isolates were evaluated using the candidate and the routine method. The candidate method had 100% accuracy for the identification of Gram negative bacteria, Staphylococcus and Enterococcus, 50% for Streptococcus and 33.3% for Corynebacterium species. Susceptibility testing of Gram negative isolates yielded 98-100% essential agreement. For Staphylococcus and Enterococcus isolates, essential agreement was 100% for 17 antibiotics except for moxifloxacin. Direct testing of blood culture samples with Vitek 2 produced reliable identification and susceptibility results 18-24h sooner for aerobic/anaerobic facultative Gram-negative bacteria and Gram-positive Staphylococcus and Enterococcus strains. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  11. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. TIME COURSE OF CHANGES IN BLOOD LIPID PARAMETERS IN PATIENTS WITH EARLY RHEUMATOID ARTHRITIS DURING TREAT-TO-TARGET ANTIRHEUMATIC THERAPY: ACCORDING TO 18-MONTH FOLLOW-UP FINDINGS

    Directory of Open Access Journals (Sweden)

    E. V. Udachkina

    2016-01-01

    Full Text Available The mechanisms for lowering a cardiovascular risk (CVR in patients with early rheumatoid arthritis (RA when implementing the treat-to-target strategy remain inadequately investigated.Objective: to estimate the time course of changes in blood lipid parameters in patients with early RA during Treat-totarget antirheumatic therapy at an 18-month follow-up.Subjects and methods. Seventy-four patients (73% women; median age, 56 years with early RA meeting the respective 2010 American College of Rheumatology/European League Against Rheumatism (ACR/EULAR classification criteria and moderate or high activity (median DAS28-ESR score of 5.4 were examined within the framework of the REMARCA trial. After 6-month treatment, RA activity significantly reduced (p < 0.05. At months 6 to 18, no significant change in RA activity was recorded. After 18 months, remission was observed in 31 (42% patients: in 17 (55% on methotrexate (MTX monotherapy and in 14 (45% on combined therapy with MTX and a biological agent. Blood lipid levels were determined at inclusion in the investigation, 6 and 18 months later. The values of lipid parameters were estimated in terms of the total CVR. 67.6% of the patients were classified as at very high CVR. At 18 months of treatment, 34 (46% patients were treated with statins (median atorvastatin and rosuvastatin doses were 10 mg/day each.Results and discussion. Only 12% of the patients had optimal baseline values of just all lipid parameters. The concentration of total cholesterol (TC, low-density lipoprotein cholesterol (LDL-C, and high-density lipoprotein cholesterol (HDL-C correlated negatively with C-reactive protein (CRP levels, DAS28-ESR, DAS28-CRP, and HAQ (p < 0.05. After 6-month treatment, there were increases in TC by 7%, LDL-C by 12.5%, and HDL-C by 19.7%, and a decrease in the atherogenic index by 16% (p < 0.05. ΔCRP negatively correlated with ΔTC, ΔLDL-C, and ΔHDL-C (r = -0.3; p < 0.05. A correlation of TC and LDL-C with

  13. Homocysteine, visceral adiposity-related novel cardiometabolic risk factors, and exaggerated blood pressure response to the exercise treadmill test.

    Science.gov (United States)

    Türker Duyuler, Pinar; Duyuler, Serkan; Demir, Mevlüt; Uçar Elalmiş, Özgül; Güray, Ümit; İleri, Mehmet

    2017-12-01

    Exaggerated blood pressure response to exercise is a risk factor for the development of future hypertension. In this study, we aimed to investigate the association between homocysteine, epicardial fat thickness, nonalcoholic hepatic steatosis, and exaggerated blood pressure response to exercise. We included 44 normotensive and 40 patients with exaggerated blood pressure response to exercise who have normal resting blood pressure and without a previous diagnosis of hypertension. All patients underwent treadmill exercise test and clinical, ultrasonographic, and echocardiographic evaluation. Exaggerated blood pressure response to exercise is defined as peak exercise systolic blood pressure of at least 210 mmHg in men and at least 190 mmHg in women. Homocysteine and other biochemical parameters were determined with standardized automated laboratory tests. Mean age of all participants is 47.9±8.5 years, and 36 of 84 participants were female. The frequency of diabetes mellitus in both groups was similar (P=0.250). Homeostasis model assessment index-insulin resistance had a statistically insignificant trend to be higher in a patient with exercise hypertension (P=0.058). The nonalcoholic fatty liver was more frequent in patients with exercise hypertension (13.6 vs. 47.5%, P=0.002). Epicardial fat thickness was increased in patients with exercise hypertension (5.5±1.5 vs. 7.3±1.1 mm; P=0.001). However, homocysteine levels did not significantly differ between normotensive and exercise hypertensive patients [12.3 μmol/l (5.7-16.9 μmol/l) vs. 13 μmol/l (5.9-28.3 μmol/l); P=0.883]. In our study, homocysteine levels were not associated with exaggerated blood pressure response to exercise; however, fatty liver and epicardial fat thickness as visceral adiposity-related cardiometabolic risk factors were significantly related with exaggerated blood pressure response to exercise in patients without a previous diagnosis of hypertension.

  14. The distribution and frequency of blood lipid testing by sociodemographic status among adults in Auckland, New Zealand.

    Science.gov (United States)

    Exeter, Daniel J; Moss, Lauren; Zhao, Jinfeng; Kyle, Cam; Riddell, Tania; Jackson, Rod; Wells, Susan

    2015-09-01

    National cardiovascular disease (CVD) guidelines recommend that adults have cholesterol levels monitored regularly. However, little is known about the extent and equity of cholesterol testing in New Zealand. To investigate the distribution and frequency of blood lipid testing by sociodemographic status in Auckland, New Zealand. We anonymously linked five national health datasets (primary care enrolment, laboratory tests, pharmaceuticals, hospitalisations and mortality) to identify adults aged ≥25 years without CVD or diabetes who had their lipids tested in 2006-2010, by age, gender, ethnicity and area of residence and deprivation. Multivariate logistic regression was used to estimate the likelihood of testing associated with these factors. Of the 627 907 eligible adults, 66.3% had at least one test between 2006 and 2010. Annual testing increased from 24.7% in 2006 to 35.1% in 2010. Testing increased with age similarly for men and women. Indian people were 87% more likely than New Zealand European and Others (NZEO) to be tested, Pacific people 8% more likely, but rates for Maori were similar to NZEO. There was marked variation within the region, with residents of the most deprived areas less likely to be tested than residents in least deprived areas. Understanding differences within and between population groups supports the development of targeted strategies for better service utilisation. While lipid testing has increased, sociodemographic variations persist by place of residence, and deprivation. Of the high CVD risk populations, lipid testing for Maori and Pacific is not being conducted according to need.

  15. Blood Pressure and Impedance Cardiography duríng Tilt Table Test

    Czech Academy of Sciences Publication Activity Database

    Jurák, Pavel; Halámek, Josef; Vondra, Vlastimil; Plachý, M.; Fráňa, P.; Leinveber, Pavel

    2009-01-01

    Roč. 36, - (2009), s. 429-432 ISSN 0276-6574 R&D Projects: GA AV ČR IAA200650801 Institutional research plan: CEZ:AV0Z20650511 Keywords : blood pressure * heart rate * thoracic impedance cardiography Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://cinc.mit.edu/archives/2009/pdf/0429.pdf

  16. Focal increase of cerebral blood flow during stereognostic testing in man

    DEFF Research Database (Denmark)

    Roland, E; Larsen, B

    1976-01-01

    An attempt was made to study the regional cerebral blood flow (rCBF) pattern during stereognostic discrimination in man. The rCBF was measured in 18 subjects who had no major neurological defects. The clearance from the hemisphere of xenon 133 injected (133Xe) into the carotid artery was measured...

  17. Evaluation of the clinical utility of a rapid blood test for human leptospirosis

    NARCIS (Netherlands)

    Eapen, C. K.; Sugathan, Sheela; Kuriakose, Mariamma; Abdoel, Theresia; Smits, Henk L.

    2002-01-01

    A rapid assay device for the detection of Leptospira-specific immunoglobulin M (IgM) antibodies was applied on whole blood samples collected from a group of consecutive patients admitted with clinical suspicion of leptospirosis to a district hospital in Kerala, India. The hospital is located in an

  18. Awareness and Knowledge of Cardiovascular Risk through Blood Pressure and Cholesterol Testing in College Freshmen

    Science.gov (United States)

    Melnyk, J. A.; Panza, G.; Zaleski, A.; Taylor, B.

    2015-01-01

    Background: Cardiovascular disease (CVD) is the leading cause of death in the United States, yet knowledge of CVD risk factors is surprisingly low in college students. Purpose: The purpose of this study was to determine the effectiveness of an individualized blood pressure, cholesterol, and CVD education intervention on college freshmen. Methods:…

  19. Reliable rapid blood test for the exclusion of venous thromboembolism in symptomatic outpatients

    NARCIS (Netherlands)

    Turkstra, F.; van Beek, E. J.; ten Cate, J. W.; Büller, H. R.

    1996-01-01

    In this study we assessed the reliability of a rapid bed-side whole blood D-dimer assay prospectively in patients with clinically suspected venous thromboembolism, referred to the Academic Medical Centre, Amsterdam. In consecutive outpatients with clinically suspected deep vein thrombosis or

  20. Glucose pump test can be used to measure blood flow rate of native arteriovenous fistula in chronic hemodialysis.

    Science.gov (United States)

    Yavuz, Y C; Selcuk, N Y; Altıntepe, L; Güney, I; Yavuz, S

    2018-01-01

    In chronic hemodialysis patients, the low flow of vascular access may leads to inadequate dialysis, increased rate of hospitalization, morbidity, and mortality. It was found that surveillance should be performed for native arteriovenous (AV) should not be performed for AV graft in various studies. However, surveillance was done in graft AV fistulas in most studies. Doppler ultrasonography (US) was suggested for surveillance of AV fistulas by the last vascular access guideline of National Kidney Foundation Disease Outcomes Quality Initiative (NKF KDOQI). The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of the infusion by glucometer. Doppler US was done by an expert radiologist. Used statistical tests were Mann-Whitney U test, Friedman test, regression analysis, and multiple regression analysis. Median values of blood flow rates measured by GPT (707 mL/min) and by Doppler US (700 mL/min) were not different (Z = 0.414, P = 0.678). Results of GPT and Doppler US measurements were positive correlate by regression analysis. The mean GPT value of diabetic patients (n = 39; 908 mL/min) was similar to that of nondiabetic patients (n = 54; 751 mL/min; Z = 1.31, P = 0.188). GPT values measured at three different dialysis session did not differ from each other that by Friedman test (F = 0.92, P = 0.39). This showed that GPT was stable and reliable. Glucose pump test can be used to measure blood flow rate of native AV fistula. GPT is an accurate and reliable test.

  1. Routine Laboratory Blood Tests May Diagnose Significant Fibrosis in Liver Transplant Recipients with Chronic Hepatitis C: A 10 Year Experience

    OpenAIRE

    Sheen, Victoria; Nguyen, Heajung; Jimenez, Melissa; Agopian, Vatche; Vangala, Sitaram; Elashoff, David; Saab, Sammy

    2016-01-01

    Background and Aims: The aims of our study were to determine whether routine blood tests, the aspartate aminotransferase (AST) to Platelet Ratio Index (APRI) and Fibrosis 4 (Fib-4) scores, were associated with advanced fibrosis and to create a novel model in liver transplant recipients with chronic hepatitis C virus (HCV). Methods: We performed a cross sectional study of patients at The University of California at Los Angeles (UCLA) Medical Center who underwent liver transplantation for HCV. ...

  2. Bayesian estimation of sensitivity and specificity of Coxiella burnetii antibody ELISA tests in bovine blood and milk

    DEFF Research Database (Denmark)

    Paul, Suman; Toft, Nils; Agerholm, Jørgen S.

    2013-01-01

    Serological tests for Coxiella burnetii (the causative agent of Q fever) antibodies are usually based on enzyme linked immunosorbent assay (ELISA) although this method is not thoroughly evaluated. The objective of this study was to determine the sensitivity and specificity of an ELISA for detection...... lactating cows is relatively easy, non-invasive and inexpensive and hence milk ELISA may be a better option for screening lactating cows. But, blood ELISA is an option for screening non-lactating cattle....

  3. Blood pressure in the initial phase of acute ischaemic stroke: evolution and its role as an independent prognosis factor at discharge and after 3 months of follow-up.

    Science.gov (United States)

    Armario, Pedro; Mártin-Baranera, Montserrat; Miguel Ceresuela, Luis; Hernández Del Rey, Raquel; Iribarnegaray, Eduardo; Pintado, Sara; Avila, Asunción; Bello, Juan; Luis Tovar, José; Alvarez-Sabin, José

    2008-01-01

    A prospective observational study was aimed at assessing the role of blood pressure (BP) during the first 24 h from stroke onset on the outcome of acute ischaemic stroke. Subjects admitted within the first 3 h from stroke onset were included. Stroke severity was evaluated with the Canadian Stroke Scale (CSS). Functional recovery was defined as a modified Rankin Scale score or =180 mmHg (OR = 13.34; 95% CI 1.34-133.10; p = 0.0272) and a lower diastolic BP average from 6 to 24 h (OR for 5 mmHg increase: 0.57; CI 95% 0.36-0.88; p = 0.0115). Similar results were observed after 3 months of follow-up. In ischaemic stroke patients, systolic BP over 180 mmHg in the first 6 h and a decrease of diastolic BP during the 6-24 h from stroke onset were independent predictors of a poor functional recovery.

  4. Acute hepatitis B virus window-period blood donations detected by individual-donation nucleic acid testing: a report on the first two cases found and interdicted in Spain.

    Science.gov (United States)

    González, Rocio; Echevarria, José Manuel; Avellón, Ana; Barea, Luisa; Castro, Emma

    2006-07-01

    Mathematical models predict that, in Spain, a significant number of blood units will be obtained during the window period of the hepatitis B virus (HBV) infection. Routine nucleic acid testing (NAT) on individual blood units may provide experimental data to evaluate such a theoretical risk. Between February and July 2005, a total of 34,631 individual units were screened for HBV DNA by a multiplex transcription-mediated amplification (TMA) test. Units that repeatedly reacted in the test, but did not react for HBV surface antigen (HBsAg), were submitted to additional testing by both molecular and conventional assays, and the donors were recalled for follow-up studies and the collection of clinical and epidemiologic data. Confirmatory testing and follow-up studies identified 2 blood units donated during the HBV infection window period (1/17,316 units studied). Sequencing of amplification products obtained by nested polymerase chain reaction (n-PCR) revealed two HBV strains from genotypes D/ayw3 and F/adw4q-, but did not identify HBsAg mutants. The HBV DNA concentration in the index donations was estimated to be below the n-PCR detection level (180 IU/mL), in both cases. One donor developed acute hepatitis 2 months after donating blood, but the other remained asymptomatic and displayed normal alanine aminotransferase levels at follow-up. The HBV infection window period is a real issue in the setting of Spanish blood transfusions. NAT of individual units by TMA would make a significant contribution to improving the safety of the blood supply in Spain. Additional studies involving a larger number of units and longer periods of time are required, however, to ascertain the true incidence of the problem in this country.

  5. A leukocyte activation test identifies food items which induce release of DNA by innate immune peripheral blood leucocytes.

    Science.gov (United States)

    Garcia-Martinez, Irma; Weiss, Theresa R; Yousaf, Muhammad N; Ali, Ather; Mehal, Wajahat Z

    2018-01-01

    Leukocyte activation (LA) testing identifies food items that induce a patient specific cellular response in the immune system, and has recently been shown in a randomized double blinded prospective study to reduce symptoms in patients with irritable bowel syndrome (IBS). We hypothesized that test reactivity to particular food items, and the systemic immune response initiated by these food items, is due to the release of cellular DNA from blood immune cells. We tested this by quantifying total DNA concentration in the cellular supernatant of immune cells exposed to positive and negative foods from 20 healthy volunteers. To establish if the DNA release by positive samples is a specific phenomenon, we quantified myeloperoxidase (MPO) in cellular supernatants. We further assessed if a particular immune cell population (neutrophils, eosinophils, and basophils) was activated by the positive food items by flow cytometry analysis. To identify the signaling pathways that are required for DNA release we tested if specific inhibitors of key signaling pathways could block DNA release. Foods with a positive LA test result gave a higher supernatant DNA content when compared to foods with a negative result. This was specific as MPO levels were not increased by foods with a positive LA test. Protein kinase C (PKC) inhibitors resulted in inhibition of positive food stimulated DNA release. Positive foods resulted in CD63 levels greater than negative foods in eosinophils in 76.5% of tests. LA test identifies food items that result in release of DNA and activation of peripheral blood innate immune cells in a PKC dependent manner, suggesting that this LA test identifies food items that result in release of inflammatory markers and activation of innate immune cells. This may be the basis for the improvement in symptoms in IBS patients who followed an LA test guided diet.

  6. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  7. Cytochalasin-b micronucleus test of peripheral blood lymphocytes of Kozloduy NPP workers

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Hristova, R.; Atanassova, P.; Stainova, A.; Popova, L.

    2006-01-01

    Full text: The cytokinesis-block micronucleus assay in peripheral blood lymphocytes was applied to evaluate occupational radiation exposure of 65 nuclear power plant workers. Blood samples were collected from 43 workers aged between 32-54 years, mean age 41,7 years. The accumulated radiation doses for each subject varied between 7,9 - 766,4 mSv, mean level of the whole group is 237,78 mSv. Controls were 22 healthy individuals, (13 male and 9 female), aged between 27-52 years, mean age 38,8 years, selected from the administrative staff. All subjects participating in this study were interviewed concerning health status, professional history, smoking habit and other aspects relevant to the study. At least 1000 binucleated cells were analysed per person. The detected frequencies of micronuclei in the control group were ranged between 4.0 and 23.5 per 1000 binucleated cells, with the average incidence yield of 12.16 ±5.59 %. The mean group value of the frequency of micronuclei in peripheral lymphocytes of exposed workers was found to be 18.46±6.72 % in 1000 cells. The difference between the mean frequency of micronuclei in the group of exposed subjects and the control group was statistically significant (P<0,001). The correlation coefficient for duration of employment and accumulated doses is 0,30 (P<0,05). After 1,5 Gy in vitro irradiation of peripheral blood from investigated workers and controls a decreased radiosensitivity of NPP workers is detected using micronucleus assay. Decreased radiosensitivity of the professionally exposed workers could be due to the phenomenon of adaptive response. Micronucleus assay in peripheral blood lymphocytes is useful approach in cytogenetic monitoring of occupationally exposed nuclear industry workers

  8. Prediction of skull fracture risk for children 0-9 months old through validated parametric finite element model and cadaver test reconstruction.

    Science.gov (United States)

    Li, Zhigang; Liu, Weiguo; Zhang, Jinhuan; Hu, Jingwen

    2015-09-01

    Skull fracture is one of the most common pediatric traumas. However, injury assessment tools for predicting pediatric skull fracture risk is not well established mainly due to the lack of cadaver tests. Weber conducted 50 pediatric cadaver drop tests for forensic research on child abuse in the mid-1980s (Experimental studies of skull fractures in infants, Z Rechtsmed. 92: 87-94, 1984; Biomechanical fragility of the infant skull, Z Rechtsmed. 94: 93-101, 1985). To our knowledge, these studies contained the largest sample size among pediatric cadaver tests in the literature. However, the lack of injury measurements limited their direct application in investigating pediatric skull fracture risks. In this study, 50 pediatric cadaver tests from Weber's studies were reconstructed using a parametric pediatric head finite element (FE) model which were morphed into subjects with ages, head sizes/shapes, and skull thickness values that reported in the tests. The skull fracture risk curves for infants from 0 to 9 months old were developed based on the model-predicted head injury measures through logistic regression analysis. It was found that the model-predicted stress responses in the skull (maximal von Mises stress, maximal shear stress, and maximal first principal stress) were better predictors than global kinematic-based injury measures (peak head acceleration and head injury criterion (HIC)) in predicting pediatric skull fracture. This study demonstrated the feasibility of using age- and size/shape-appropriate head FE models to predict pediatric head injuries. Such models can account for the morphological variations among the subjects, which cannot be considered by a single FE human model.

  9. Survival of transfused red blood cells: In vivo compatibility testing with chromium-51

    International Nuclear Information System (INIS)

    Dharkar, D.D.; Pineda, A.A.

    1983-01-01

    The /sup 51/Cr red cell survival test and specific test for measurement of the disappearance rate of labeled red cells. This procedure can be used for the assessment of red cell compatibility testing in vivo. The authors recommend that more routine transfusions as well as ''difficult'' transfusions be monitored by /sup 51/Cr in vivo compatibility testing before the actual transfusions, so that more consistent and reliable survival values are achieved

  10. Evaluation of Blood-Based Antibody Rapid Testing for HIV Early Therapy: A Meta-Analysis of the Evidence

    Directory of Open Access Journals (Sweden)

    Xiaojie Huang

    2018-06-01

    Full Text Available BackgroundWestern blot (WB assay is considered the gold standard test for HIV infection confirmation. However, it requires technical expertise and is quite time-consuming. WHO recommends blood-based rapid diagnosis to achieve same-day test and treatment. However, this rapid testing strategy has not been promoted worldwide due to inadequate research evaluating the effectiveness of rapid tests (RTs as an alternative confirmatory HIV test for WB. This study aims to compare the diagnostic performance of rapid HIV tests compared with WB.MethodsPubMed and Web of Science were searched for publications on rapid HIV tests using blood specimen. A meta-analysis was performed to quantitatively evaluate the diagnostic performance of rapid HIV tests compared with the WB assay in terms of pooled sensitivity, specificity, area under summary receiver operating characteristic (SROC curve, and diagnostic odds ratio (DOR.ResultsTwenty articles involving 27,343 fresh specimens for rapid HIV tests were included in the meta-analysis. Regarding Capillus HIV-1/HIV-2, the pooled sensitivity, specificity, area under SROC curve, and DOR derived from six studies were 0.999 (95% CI, 0.956–1.000, 0.999 (95% CI, 0.991–1.00, 1.00 (95% CI, 0.99–1.00, and 1.0 × 106 (95% CI, 2.6 × 104–3.9 × 107 compared with the WB assay, respectively. With respect to Determine HIV-1/2, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 1.00 (95% CI, 0.789–1.000, 0.992 (95% CI, 0.985–0.996, 1.00 (95% CI, 0.99–1.00, and 1.8 × 106 (95% CI 406.049–7.8 × 109 compared with the WB assay, respectively. Regarding two-step serial RTs, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 0.998 (95% CI, 0.991–1.000, 0.998 (95% CI, 0.994–0.999, and 1.00 (95% CI 0.99–1.00 compared with the WB assay, respectively.ConclusionOur meta-analysis results may provide evidenced-based support

  11. Including osteoprotegerin and collagen IV in a score-based blood test for liver fibrosis increases diagnostic accuracy.

    Science.gov (United States)

    Bosselut, Nelly; Taibi, Ludmia; Guéchot, Jérôme; Zarski, Jean-Pierre; Sturm, Nathalie; Gelineau, Marie-Christine; Poggi, Bernard; Thoret, Sophie; Lasnier, Elisabeth; Baudin, Bruno; Housset, Chantal; Vaubourdolle, Michel

    2013-01-16

    Noninvasive methods for liver fibrosis evaluation in chronic liver diseases have been recently developed, i.e. transient elastography (Fibroscan™) and blood tests (Fibrometer®, Fibrotest®, and Hepascore®). In this study, we aimed to design a new score in chronic hepatitis C (CHC) by selecting blood markers in a large panel and we compared its diagnostic performance with those of other noninvasive methods. Sixteen blood tests were performed in 306 untreated CHC patients included in a multicenter prospective study (ANRS HC EP 23 Fibrostar) using METAVIR histological fibrosis stage as reference. The new score was constructed by non linear regression using the most accurate biomarkers. Five markers (alpha-2-macroglobulin, apolipoprotein-A1, AST, collagen IV and osteoprotegerin) were included in the new function called Coopscore©. Using the Obuchowski Index, Coopscore© shows higher diagnostic performances than for Fibrometer®, Fibrotest®, Hepascore® and Fibroscan™ in CHC. Association between Fibroscan™ and Coopscore© might avoid 68% of liver biopsies for the diagnosis of significant fibrosis. Coopscore© provides higher accuracy than other noninvasive methods for the diagnosis of liver fibrosis in CHC. The association of Coopscore© with Fibroscan™ increases its predictive value. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  13. Dynamics of changes in the activation of blood coagulation tests at different variants of thromboprophylaxis

    Directory of Open Access Journals (Sweden)

    Олена Миколаївна Клигуненко

    2015-09-01

    Full Text Available Aim: To study an influence of the different variants of thromboprophylaxis on activation of blood coagulation test on the background of surgical aggression. D-dimer concentration in serum is in direct proportion to fibrinolysis activity and to an amount of lysed fibrin. At the same time fibrinolysis activation is followed with an increase of formation of products of fibrin degradation (PFD that interact with fibrin-monomers and increase the number of SFMC.Materials and methods: After informed consent 200 patients were prospectively divided into groups depending on preparation and regimen of thromboprophylaxis. 1 group (n=30 – ungraded heparin (UGH (5000 ОD for 2 hours before surgery 2 times during 7 days after it. 2 group(n=30 nadraparin calcium 9500 anti-Ха МO (0,3 ml for 2 hours before surgery 2500 МО 1 time for a day 7 days after surgery; 3 group(n=48 – endoxaparin sodium(0,2 ml for 2 hours before surgery 1 time a day 7 days; 4 group(n=29 endoxaparin sodium(0,2ml for 8 hours before surgery, 0,2 ml 1 time a day 7 days; 5 group(n=34 – bemiparin sodium(0,2 ml for 2 hours before surgery 0,2 ml 1 time a day 7 days; 6 group(n=29 bemiparin sodium(0,2ml in 6 hours after surgery 1 time a day 7 days. Patients were comparable on sex, concomitant pathology, class АSA (1-2 and type of surgical intervention. There were studied the number of thrombocytes, prothrombin time (PT, INR AFTT, fibrinogen, Х-а factor activity, antithrombin, 111 (AT111, protein C, SFMC, d-dimer before surgery, on 1,5 and 7 day after it.Results and discussions: On the 1 day of postsurgical period the most influence on D-dimer level had presurgical thromboprophylaxis (TPP with UGH and nadroparin calcium. So the D-dimer level exceeded norm respectively by 67 % (р=0,017 and 65,9 % (р<0,05. In patients of 3 and 4 groups D-dimer level was the lowest that formed deficiency by 56 % (р<0,05 and 52,7 % (р<0,05 from the norm respectively. At the same time an analysis of

  14. Both the frequency of HbA1c testing and the frequency of self-monitoring of blood glucose predict metabolic control: A multicentre analysis of 15 199 adult type 1 diabetes patients from Germany and Austria.

    Science.gov (United States)

    Schwandt, A; Best, F; Biester, T; Grünerbel, A; Kopp, F; Krakow, D; Laimer, M; Wagner, C; Holl, R W

    2017-10-01

    The objective of this study was to examine the association between metabolic control and frequency of haemoglobin A 1c (HbA 1c ) measurements and of self-monitoring of blood glucose, as well as the interaction of both. Data of 15 199 adult type 1 diabetes patients registered in a standardized electronic health record (DPV) were included. To model the association between metabolic control and frequency of HbA 1c testing or of self-monitoring of blood glucose, multiple hierarchic regression models with adjustment for confounders were fitted. Tukey-Kramer test was used to adjust P values for multiple comparisons. Vuong test was used to compare non-nested models. The baseline variables of the study population were median age 19.9 [Q1; Q3: 18.4; 32.2] years and diabetes duration 10.4 [6.8; 15.7] years. Haemoglobin A 1c was 60.4 [51.5; 72.5] mmol/mol. Frequency of HbA 1c testing was 8.0 [5.0; 9.0] within 2 years, and daily self-monitoring of blood glucose frequency was 5.0 [4.0; 6.0]. After adjustment, a U-shaped association between metabolic control and frequency of HbA 1c testing was observed with lowest HbA 1c levels in the 3-monthly HbA 1c testing group. There was an inverse relationship between self-monitoring of blood glucose and HbA 1c with lower HbA 1c associated with highest frequency of testing (>6 daily measurements). Quarterly HbA 1c testing and frequent self-monitoring of blood glucose were associated with best metabolic control. The adjusted Vuong Z statistic suggests that metabolic control might be better explained by HbA 1c testing compared to self-monitoring of blood glucose (P < .0001). This research reveals the importance of quarterly clinical HbA 1c monitoring together with frequent self-monitoring of blood glucose in diabetes management to reach and maintain target HbA 1c . Copyright © 2017 John Wiley & Sons, Ltd.

  15. Ethical, Legal and Social Issues in Japan on the Determination of Blood Relationship via DNA Testing.

    Science.gov (United States)

    Toya, Waki

    2017-01-01

    DNA paternity testing has recently become more widely available in Japan. The aim of this paper is to examine the issues surrounding (1) the implementing agency, whether the testing is conducted in a commercial direct-to-consumer (DTC) setting or a judicial non-DTC setting, and (2) the implementation conditions and more specifically the legal capacity of the proband (test subject). Literature research in Japanese and English was conducted. Some countries prohibit commercial DNA testing without the consent of the proband or her or his legally authorized representative. But as in some cases, the results of DTC paternity testing have proven to be unreliable. I propose a complete prohibition of DTC DNA paternity testing in Japan. In many cases of paternity testing, the proband is a minor. This has led to debate about whether proxy consent is sufficient for paternity testing or whether additional safeguards (such as a court order) are required. In cases where commercial DNA testing has been conducted and the test results are produced in court as evidence, the court must judge whether or not to admit these results as evidence. Another important issue is whether or not paternity testing should be legally mandated in certain cases. If we come to the conclusion that DNA test results are the only way to conclusively establish a parent-child relationship, then our society may prioritize even more genetic relatedness over other conceptions of a parent-child relationship. This prioritization could adversely affect families created through assisted reproductive technology (ART), especially in situations where children are not aware of their biological parentage. This paper argues for a complete prohibition of DTC DNA paternity testing in Japan, and highlights that broader ethical and legal deliberation on such genetic services is required.

  16. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  17. Shortened Time to Identify Staphylococcus Species from Blood Cultures and Methicillin Resistance Testing Using CHROMAgar

    Directory of Open Access Journals (Sweden)

    Shingo Chihara

    2009-01-01

    Full Text Available The ability to rapidly differentiate coagulase-negative staphylococcus (CoNS from Staphylococcus aureus and to determine methicillin resistance is important as it affects the decision to treat empiric antibiotic selection. The objective of this study was to evaluate CHROMagar S. aureus and CHROMagar MRSA (Becton Dickinson for rapid identification of Staphylococcus spp. directly from blood cultures. Consecutive blood culture bottles (BacT Alert 3D SA and SN, bioMérieux growing gram-positive cocci in clusters were evaluated. An aliquot was plated onto CHROMagar MRSA (C-MRSA and CHROMagar S. aureus (C-SA plates, which were read at 12 to 16 hours. C-SA correctly identified 147/147 S. aureus (100% sensitivity; 2 CoNS were misidentified as S. aureus (98% specificity. C-MRSA correctly identified 74/77 MRSA (96% sensitivity. None of the MSSA isolates grew on C-MRSA (100% specificity. In conclusion, CHROMagar is a rapid and sensitive method to distinguish MRSA, MSSA, and coagulase-negative Staphylococcus and may decrease time of reporting positive results.

  18. Useful method to monitor the physiological effects of alcohol ingestion by combination of micro-integrated laser Doppler blood flow meter and arm-raising test.

    Science.gov (United States)

    Iwasaki, Wataru; Nogami, Hirofumi; Ito, Hiroki; Gotanda, Takeshi; Peng, Yao; Takeuchi, Satoshi; Furue, Masutaka; Higurashi, Eiji; Sawada, Renshi

    2012-10-01

    Alcohol has a variety of effects on the human body, affecting both the sympathetic and parasympathetic nervous system. We examined the peripheral blood flow of alcohol drinkers using a micro-integrated laser Doppler blood flow meter (micro-electromechanical system blood flow sensor). An increased heart rate and blood flow was recorded at the earlobe after alcohol ingestion, and we observed strong correlation between blood flow, heart rate, and breath alcohol content in light drinkers; but not heavy drinkers. We also found that the amplitude of pulse waves measured at the fingertip during an arm-raising test significantly decreased on alcohol consumption, regardless of the individual's alcohol tolerance. Our micro-electromechanical system blood flow sensor successfully detected various physiological changes in peripheral blood circulation induced by alcohol consumption.

  19. Development, reliability, and validity testing of Toddler NutriSTEP: a nutrition risk screening questionnaire for children 18-35 months of age.

    Science.gov (United States)

    Randall Simpson, Janis; Gumbley, Jillian; Whyte, Kylie; Lac, Jane; Morra, Crystal; Rysdale, Lee; Turfryer, Mary; McGibbon, Kim; Beyers, Joanne; Keller, Heather

    2015-09-01

    Nutrition is vital for optimal growth and development of young children. Nutrition risk screening can facilitate early intervention when followed by nutritional assessment and treatment. NutriSTEP (Nutrition Screening Tool for Every Preschooler) is a valid and reliable nutrition risk screening questionnaire for preschoolers (aged 3-5 years). A need was identified for a similar questionnaire for toddlers (aged 18-35 months). The purpose was to develop a reliable and valid Toddler NutriSTEP. Toddler NutriSTEP was developed in 4 phases. Content and face validity were determined with a literature review, parent focus groups (n = 6; 48 participants), and experts (n = 13) (phase A). A draft questionnaire was refined with key intercept interviews of 107 parents/caregivers (phase B). Test-retest reliability (phase C), based on intra-class correlations (ICC), Kappa (κ) statistics, and Wilcoxon tests was assessed with 133 parents/caregivers. Criterion validity (phase D) was assessed using Receiver Operating Characteristic (ROC) curves by comparing scores on the Toddler NutriSTEP to a comprehensive nutritional assessment of 200 toddlers with a registered dietitian (RD). The Toddler NutriSTEP was reliable between 2 administrations (ICC = 0.951, F = 20.53, p Toddler NutriSTEP were correlated (r = 0.67, p Toddler NutriSTEP questionnaire is both reliable and valid for screening for nutritional risk in toddlers.

  20. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC).

    Science.gov (United States)

    Sarkodie, F; Hassall, O; Owusu-Dabo, E; Owusu-Ofori, S; Bates, I; Bygbjerg, I C; Owusu-Ofori, A; Harritshøj, L H; Ullum, H

    2017-02-01

    Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma reagin (RPR) test at Komfo Anokye Teaching Hospital (KATH), Ghana. From February 2014 to January 2015, 5 mL of venous blood samples were taken from 16 016 blood donors and tested with a treponemal RDT; 5 mL of venous blood was taken from 526 consenting initial syphilis sero-reactive blood donors. These RDT reactive samples were confirmed with an algorithm, applying the Vitros ® /Abbott-Architect ® algorithm as gold standard. A total of 478 of 526 RDT reactive donors were confirmed positive for syphilis, making a PPV of 90·9%. Of the 172 (32·7%) donors who were also RPR positive, 167 were confirmed, resulting in a PPV of 97·1%. The PPV of the combined RDT and RPR (suspected active syphilis) testing algorithm was highest among donors at an enhanced risk of syphilis, family/replacement donors (99·9%), and among voluntary donors above 25 years (98·6%). Screening of blood donors by combining syphilis RDT and RPR with relatively good PPV may provide a reasonable technology for LMIC that has a limited capacity for testing and can contribute to the improvement of blood safety with a minimal loss of donors. © 2016 British Blood Transfusion Society.

  1. Public banking of umbilical cord blood or storage in a private bank: testing social and ethical policy in northeastern Italy

    Directory of Open Access Journals (Sweden)

    Parco S

    2013-04-01

    Full Text Available Sergio Parco, Fulvia Vascotto, Patrizia Visconti Institute for Maternal and Child Health, Trieste, Italy Background: In northeastern Italy, according to Italian legislation, authorized public facilities can accept the donation and preservation of cord blood stem cells (CB-SC. Attitudes and knowledge in pregnant women differs between the local and immigrant (non-European Union [EU] population. In this study we assessed the choices that pregnant women have with respect to the public and private harvesting system and the main reasons driving their decisions. We examined the ethnic origin of the families and compared tests for syphilis screening and leukocyte (WBC counts in the CB-SC bags that are required for validation of the collection. Methods: Out of a population of 3450 pregnant patients at the Institute for Maternal and Child Health of Trieste, northeast Italy, 772 women agreed to cord blood harvesting and the associated lab tests. Of these, 221 women (28.6% were from immigrant families of non-EU countries. Their ethnic affiliation was recorded, and tests were performed for syphilis screening and for nucleated red blood cell (NRBC interference with the WBC count in CB-SC bags to assess cellularity and to determine if storage was appropriate. Results: Of the 772 pregnant women, 648 (84.0% accessed the public collection system, which is free of charge, and 124 (15.0% accessed the private fee-based system. One woman from the non-EU group opted for the private fee-based system. Of the 3450 pregnant women screened for syphilis at the Institute for Maternal and Child Health, the Treponema pallidum hemagglutination (TPHA and Venereal Disease Research Laboratory (VDRL tests were the main tests performed (66.0% of total cases because many gynecologists in the public harvesting system apply the Italian regulations of the 1988 Decree, while the private system requires tests on syphilis and leaves the option to the lab physicians to select the best

  2. A single dual-emissive nanofluorophore test paper for highly sensitive colorimetry-based quantification of blood glucose.

    Science.gov (United States)

    Huang, Xiaoyan; Zhou, Yujie; Liu, Cui; Zhang, Ruilong; Zhang, Liying; Du, Shuhu; Liu, Bianhua; Han, Ming-Yong; Zhang, Zhongping

    2016-12-15

    Fluorescent test papers are promising for the wide applications in the assays of diagnosis, environments and foods, but unlike classical dye-absorption-based pH test paper, they are usually limited in the qualitative yes/no type of detection by fluorescent brightness, and the colorimetry-based quantification remains a challenging task. Here, we report a single dual-emissive nanofluorophore probe to achieve the consecutive color variations from blue to red for the quantification of blood glucose on its as-prepared test papers. Red quantum dots were embedded into silica nanoparticles as a stable internal standard emission, and blue carbon dots (CDs) were further covalently linked onto the surface of silica, in which the ratiometric fluorescence intensity of blue to red is controlled at 5:1. While the oxidation of glucose induced the formation of Fe(3+) ions, the blue emission of CDs was thus quenched by the electron transfer from CDs to Fe(3+), displaying a serial of consecutive color variations from blue to red with the dosage of glucose. The high-quality test papers printed by the probe ink exhibited a dosage-sensitive allochromatic capability with the clear differentiations of ~5, 7, 9, 11mM glucose in human serum (normal: 3-8mM). The blood glucose determined by the test paper was almost in accordance with that measured by a standard glucometer. The method reported here opens a window to the wide applications of fluorescent test paper in biological assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Does Subjective Rating Reflect Behavioural Coding? Personality in 2 Month-Old Dog Puppies: An Open-Field Test and Adjective-Based Questionnaire.

    Directory of Open Access Journals (Sweden)

    Shanis Barnard

    Full Text Available A number of studies have recently investigated personality traits in non-human species, with the dog gaining popularity as a subject species for research in this area. Recent research has shown the consistency of personality traits across both context and time for adult dogs, both when using questionnaire based methods of investigation and behavioural analyses of the dogs' behaviour. However, only a few studies have assessed the correspondence between these two methods, with results varying considerably across studies. Furthermore, most studies have focused on adult dogs, despite the fact that an understanding of personality traits in young puppies may be important for research focusing on the genetic basis of personality traits. In the current study, we sought to evaluate the correspondence between a questionnaire based method and the in depth analyses of the behaviour of 2-month old puppies in an open-field test in which a number of both social and non-social stimuli were presented to the subjects. We further evaluated consistency of traits over time by re-testing a subset of puppies. The correspondence between methods was high and test- retest consistency (for the main trait was also good using both evaluation methods. Results showed clear factors referring to the two main personality traits 'extroversion,' (i.e. the enthusiastic, exuberant approach to the stimuli and 'neuroticism,' (i.e. the more cautious and fearful approach to the stimuli, potentially similar to the shyness-boldness dimension found in previous studies. Furthermore, both methods identified an 'amicability' dimension, expressing the positive interactions the pups directed at the humans stranger, and a 'reservedness' dimension which identified pups who largely chose not to interact with the stimuli, and were defined as quiet and not nosey in the questionnaire.

  4. Does Subjective Rating Reflect Behavioural Coding? Personality in 2 Month-Old Dog Puppies: An Open-Field Test and Adjective-Based Questionnaire.

    Science.gov (United States)

    Barnard, Shanis; Marshall-Pescini, Sarah; Passalacqua, Chiara; Beghelli, Valentina; Capra, Alexa; Normando, Simona; Pelosi, Annalisa; Valsecchi, Paola

    2016-01-01

    A number of studies have recently investigated personality traits in non-human species, with the dog gaining popularity as a subject species for research in this area. Recent research has shown the consistency of personality traits across both context and time for adult dogs, both when using questionnaire based methods of investigation and behavioural analyses of the dogs' behaviour. However, only a few studies have assessed the correspondence between these two methods, with results varying considerably across studies. Furthermore, most studies have focused on adult dogs, despite the fact that an understanding of personality traits in young puppies may be important for research focusing on the genetic basis of personality traits. In the current study, we sought to evaluate the correspondence between a questionnaire based method and the in depth analyses of the behaviour of 2-month old puppies in an open-field test in which a number of both social and non-social stimuli were presented to the subjects. We further evaluated consistency of traits over time by re-testing a subset of puppies. The correspondence between methods was high and test- retest consistency (for the main trait) was also good using both evaluation methods. Results showed clear factors referring to the two main personality traits 'extroversion,' (i.e. the enthusiastic, exuberant approach to the stimuli) and 'neuroticism,' (i.e. the more cautious and fearful approach to the stimuli), potentially similar to the shyness-boldness dimension found in previous studies. Furthermore, both methods identified an 'amicability' dimension, expressing the positive interactions the pups directed at the humans stranger, and a 'reservedness' dimension which identified pups who largely chose not to interact with the stimuli, and were defined as quiet and not nosey in the questionnaire.

  5. The Test of Infant Motor Performance at 3 months predicts language, cognitive, and motor outcomes in infants born preterm at 2 years of age.

    Science.gov (United States)

    Peyton, Colleen; Schreiber, Michael D; Msall, Michael E

    2018-03-13

    To determine the relationship between the Test of Infant Motor Performance (TIMP) at 3 months and cognitive, language, and motor outcomes on the Bayley Scales of Infant and Toddler Development, Third Edition (Bayley-III) at 2 years of age in high-risk infants born preterm. One hundred and six infants (47 females, 59 males) born at earlier than 31 weeks gestational age were prospectively tested with the TIMP at 10 to 15 weeks after term age and were assessed again with the Bayley-III at 2 years corrected age. Sensitivity and specificity were calculated for various cut points of the TIMP z-score and Bayley-III composite scores of no more than 85. The TIMP z-scores at 10 to 15 weeks of age were significantly associated with all three subscales on the Bayley-III at 2 years of age (pcognitive (87%), language (88%), and motor (89%) outcomes, but sensitivity was low (cognitive 41%, language 49%, motor 57%). This study demonstrates that the TIMP is related to cognitive, language, and motor outcomes on the Bayley-III at 2 years of age in high-risk infants born preterm. The Test of Infant Motor Performance (TIMP) predicts Bayley Scales of Infant and Toddler Development, Third Edition outcomes at 2 years of age. The TIMP is relatively good at discriminating between children who will and will not have typical development. © 2018 Mac Keith Press.

  6. Regional cerebral blood flow in schizophrenics. Tests using the xenon Xe 133 inhalation method

    International Nuclear Information System (INIS)

    Ariel, R.N.; Golden, C.J.; Berg, R.A.; Quaife, M.A.; Dirksen, J.W.; Forsell, T.; Wilson, J.; Graber, B.

    1983-01-01

    Measurements of intrahemispheric and bilateral regional cerebral blood flow (CBF) for gray and white matter were compared in 29 schizophrenic patients and 22 normal controls, using the xenon Xe 133 inhalation method. Results showed significantly lower CBF values for all brain regions in the schizophrenic group, and post hoc comparisons showed relatively greater reduced gray-matter CBF values in the anterior areas of the brain. There was also a left-hemisphere frontal loss similar to that reported previously, although it was in the context of a generalized loss in anterior functioning. Interhemispheric comparison within both groups showed no differences between homologous regions for gray matter, and greater white-matter CBF values in the right hemisphere than in the left hemisphere. The findings support a hypothesis of a bilateral anterior deficit in schizophrenia

  7. Risk stratification and detection of new colorectal neoplasms after colorectal cancer screening with faecal occult blood test

    DEFF Research Database (Denmark)

    Bjerrum, Andreas; Milter, Maya Christel; Andersen, Ole

    2015-01-01

    BACKGROUND: Limited data exist on adenoma surveillance as recommended in the European guidelines for quality assurance in colorectal cancer (CRC) screening and diagnosis after faecal occult blood test (FOBT) screening. OBJECTIVE: To assess the European guidelines for adenoma surveillance after CRC...... of CRC was higher in risk group C than A (RR 5.20, 95% confidence interval: 0.63-42.58), but not statistically significant. In risk group C, half of new advanced adenomas were detected within the first year and four of nine CRC were detected within 3 years. CONCLUSION: Risk stratification of adenoma...

  8. CYP3A5*3 and ABCB1 61A>G Significantly Influence Dose-adjusted Trough Blood Tacrolimus Concentrations in the First Three Months Post-Kidney Transplantation.

    Science.gov (United States)

    Hu, Rong; Barratt, Daniel T; Coller, Janet K; Sallustio, Benedetta C; Somogyi, Andrew A

    2018-03-30

    Tacrolimus (TAC) is a first-line immunosuppressant used to prevent organ rejection after kidney transplantation. There is large inter-individual variability in its pharmacokinetics. Single nucleotide polymorphisms (SNPs) in genes encoding TAC metabolizing enzymes cytochromes P450 3A4/5 (CYP3A4/5), P-glycoprotein efflux transporter (ABCB1), their expression regulator pregnane X receptor (NR1I2) and CYP3A co-factor cytochrome P450 reductase (POR) have been studied for their effects on tacrolimus disposition. However, except for CYP3A5*3, controversies remain about their roles in predicting dose-adjusted trough blood TAC concentrations (C 0 /D). This study aimed to investigate the effects of ABCB1 (61A>G, 1199G>A, 1236C>T, 2677G>T and 3435C>T), CYP3A4*22, CYP3A5*3, NR1I2 (8055C>T, 63396C>T and -25385C>T) and POR*28 SNPs on TAC C 0 /D. In total, 165 kidney transplant recipients were included in this study. SNPs were genotyped by probe-based real-time polymerase chain reaction. Associations between log-transformed whole blood TAC C 0 /D (measured at 1 and 3 months post-transplant) and genotypes/haplotypes were assessed by linear mixed effects analysis, controlling for age, sex and haematocrit. It was observed that CYP3A5 expressors (*1/*1 + *1/*3) (p = 5.5 × 10 -16 ) and ABCB1 61G allele carriers (p = 0.001) had lower log-transformed TAC C 0 /D (56% and 26% lower geometric mean TAC C 0 /D, respectively) and accounted for approximately 30% and 4%, respectively, of log-transformed TAC C 0 /D variability in the first 3 months post-transplant. In conclusion, CYP3A5*3 is a major, and ABCB1 61A>G is a novel, although minor, genetic factor affecting TAC C 0 /D in kidney transplant recipients. © 2018 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  9. Medical Tests and Procedures for Finding and Treating Heart and Blood Vessel Disease

    Science.gov (United States)

    ... Coronary calcium scan Health care providers use electron-beam computed tomography (to-MOG-rah-fee) (EBCT) or ... how the heart performs during activity, such as walking on a moving treadmill. A medication stress test ...

  10. Routine blood tests to predict liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Hsieh, Yung-Yu; Tung, Shui-Yi; Lee, Kamfai; Wu, Cheng-Shyong; Wei, Kuo-Liang; Shen, Chien-Heng; Chang, Te-Sheng; Lin, Yi-Hsiung

    2012-02-28

    To verify the usefulness of FibroQ for predicting fibrosis in patients with chronic hepatitis C, compared with other noninvasive tests. This retrospective cohort study included 237 consecutive patients with chronic hepatitis C who had undergone percutaneous liver biopsy before treatment. FibroQ, aspartate aminotransferase (AST)/alanine aminotransferase ratio (AAR), AST to platelet ratio index, cirrhosis discriminant score, age-platelet index (API), Pohl score, FIB-4 index, and Lok's model were calculated and compared. FibroQ, FIB-4, AAR, API and Lok's model results increased significantly as fibrosis advanced (analysis of variance test: P fibrosis score in chronic hepatitis C compared with other noninvasive tests. FibroQ is a simple and useful test for predicting significant fibrosis in patients with chronic hepatitis C.

  11. Some performance effects of age and low blood alcohol levels on a computerized neuropsychological test.

    Science.gov (United States)

    1995-02-01

    COGSCREEN is a computerized test battery developed for the Federal Aviation Administration as an airman neuropsychological screening instrument for cognitive functioning. This study explored a multifaceted application of the sensitivity of the batter...

  12. Development of a blood-based molecular biomarker test for identification of schizophrenia before disease onset

    NARCIS (Netherlands)

    M.K. Chan (Man K.); M.-O. Krebs (M-O); D. Cox; P.C. Guest (Paul); R.H. Yolken; H. Rahmoune (Hassan); M. Rothermundt (Matthias); J. Steiner (Johann); F.M. Leweke (Marcus); N.J.M. van Beveren (Nico); D. Niebuhr (David); N. Weber (Natalya); D. Cowan (David); P. Suarez-Pinilla; B. Crespo-Facorro (Benedicto); C. Mam-Lam-Fook; J. Bourgin; R.J. Wenstrup (Richard); R.R. Kaldate; J.D. Cooper (Jason); S. Bahn (Sabine)

    2015-01-01

    markdownabstractRecent research efforts have progressively shifted towards preventative psychiatry and prognostic identification of individuals before disease onset. We describe the development of a serum biomarker test for the identification of individuals at risk of developing schizophrenia based

  13. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  14. [Cytochemical parameters of myeloperoxidase activity and catecholamine level in blood of postpartum women living in areas near the Semipalatinsk nuclear test site].

    Science.gov (United States)

    Kokabaeva, A E; Bazeliuk, L T

    2002-01-01

    The activity of neitrophil myeloperoxidase and content of blood etyrhrocyte cathecholamines in the blood of women in early postpartum period in dependence on distance of their living area from Semipalatinsk nuclear testing were studied. It was found that women who live closer to Semipalatinsk were characterised by significantly lower neitrophil myeloperoxidase activity and content of cathecholamines in erythrocytes than in control.

  15. Biogas desulfurization with a new developed doped activated carbon. 20 month pilot test; Biogasfeinentschwefelung mittels neu entwickelter dotierter Aktivkohle. 20-monatiger Praxistest

    Energy Technology Data Exchange (ETDEWEB)

    Rossow, Silvana; Deerberg, Goerge; Goetze, Toralf; Kanswohl, Norbert; Nelles, Michael [Univ. Rostock (Germany). Lehrstuhl fuer Abfall- und Stoffstromwirtschaft

    2009-05-15

    Doped activated carbon is a special developed activated carbon for the desulfurization of technical gases. Based on its special adsorption properties, it is able to bond a large amount of hydrogen sulfide. By the special manufacturing method it was possible to optimize further the performance for the desulfurization of gases. In a biogas plant with an installed electric capacity of 2 MW the functionality of the doped activated carbon was proofed in a real biogas stream in a 20 month pilot test. The activated carbon was used in a special adsorption system that was tunes on the requirement of the activated carbon and on the site of installation. Because the biogas plant was in the starting period, all the time there were variable operation conditions. In spite of the variable conditions the doped activated carbon shows a permanent complete desulfurization, as in the executed laboratory experiments. By the use of the desulfurization system the concentration of hydrogen sulfide is decreased less than 1 ppm. The prejudices with are often caused by hydrogen sulphide could not identify until now. A positive evidence of the excellent desulfurization is the doubling of the oil lifetime of the block heating station. (orig.)

  16. Public banking of umbilical cord blood or storage in a private bank: testing social and ethical policy in northeastern Italy.

    Science.gov (United States)

    Parco, Sergio; Vascotto, Fulvia; Visconti, Patrizia

    2013-01-01

    In northeastern Italy, according to Italian legislation, authorized public facilities can accept the donation and preservation of cord blood stem cells (CB-SC). Attitudes and knowledge in pregnant women differs between the local and immigrant (non-European Union [EU]) population. In this study we assessed the choices that pregnant women have with respect to the public and private harvesting system and the main reasons driving their decisions. We examined the ethnic origin of the families and compared tests for syphilis screening and leukocyte (WBC) counts in the CB-SC bags that are required for validation of the collection. Out of a population of 3450 pregnant patients at the Institute for Maternal and Child Health of Trieste, northeast Italy, 772 women agreed to cord blood harvesting and the associated lab tests. Of these, 221 women (28.6%) were from immigrant families of non-EU countries. Their ethnic affiliation was recorded, and tests were performed for syphilis screening and for nucleated red blood cell (NRBC) interference with the WBC count in CB-SC bags to assess cellularity and to determine if storage was appropriate. Of the 772 pregnant women, 648 (84.0%) accessed the public collection system, which is free of charge, and 124 (15.0%) accessed the private fee-based system. One woman from the non-EU group opted for the private fee-based system. Of the 3450 pregnant women screened for syphilis at the Institute for Maternal and Child Health, the Treponema pallidum hemagglutination (TPHA) and Venereal Disease Research Laboratory (VDRL) tests were the main tests performed (66.0% of total cases) because many gynecologists in the public harvesting system apply the Italian regulations of the 1988 Decree, while the private system requires tests on syphilis and leaves the option to the lab physicians to select the best determination method. We found that the chemiluminescence method was more specific (97.0%) than the TPHA (83.0%) and nontreponemal rapid plasma reagin

  17. State Blood Alcohol Concentration (BAC) Testing and Reporting for Drivers Involved in Fatal Crashes : Current Practices, Results, and Strategies, 1997-2009

    Science.gov (United States)

    2012-08-01

    This report documents current State blood alcohol concentration (BAC) testing and reporting practices and results for drivers involved in fatal crashes. It summarizes known BAC results by State for the years 1997 to 2009 for both fatally injured and ...

  18. Why testes are resistant to hydatidosis: Is blood-testis-barrier ...

    African Journals Online (AJOL)

    Testes are extremely rare sites for echinococcosis. To our knowledge only three cases of testicular hydatid disease have been reported so far. In this laboratory animal model, we studied hydatidosis in rabbit testis. Fourteen male albino rabbits (body weight 2.5-3 kg) were randomized into two groups: Group A (study group), ...

  19. The role of point-of-care blood testing for ketones in the diagnosis of ...

    African Journals Online (AJOL)

    estimated that the annual cost of treating DKA in the USA exceeds. 1 billion ... If urinary ketones are positive, patients are referred for further management – often ... To evaluate a hand-held electrochemical (point-of-care testing; POCT) ketone monitor and compare it with the gold-standard ..... renal failure may be present.

  20. Observer and biological variation of a rapid whole blood D-dimer test

    NARCIS (Netherlands)

    Turkstra, F.; van Beek, E. J.; Büller, H. R.

    1998-01-01

    In consecutive patients with suspected venous thromboembolism the interobserver variability of the SimpliRED D-dimer test was evaluated by two observers who independently scored one plate, the between assay variation was performed simultaneously by a third independent observer, who assessed a second

  1. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi.

    Science.gov (United States)

    Finno, Carrie J; Packham, Andrea E; David Wilson, W; Gardner, Ian A; Conrad, Patricia A; Pusterla, Nicola

    2007-05-01

    The purpose of this study was to determine the effect of blood contamination of cerebrospinal fluid (CSF) on the results of indirect fluorescent antibody tests (IFATs) for Sarcocystis neurona and Neospora hughesi. The in vitro study used antibody-negative CSF collected from non-neurologic horses immediately after euthanasia and blood samples from 40 healthy horses that had a range of IFAT antibody titers against S. neurona and N. hughesi. Serial dilutions of whole blood were made in seronegative CSF to generate blood-contaminated CSF with red blood cell (RBC) concentrations ranging from 10 to 100,000 RBCs/microl. The blood-contaminated CSF samples were then tested for antibodies against both pathogens using IFAT. Blood contamination of CSF had no detectable effect on IFAT results for S. neurona or N. hughesi at any serologic titer when the RBC concentration in CSF was or=5) for S. neurona and N. hughesi were detected only when the corresponding serum titers were >or=160 and >or=80, respectively. The IFAT performed on CSF is reliable for testing horses for equine protozoal myeloencephalitis caused by S. neurona or N. hughesi, even when blood contamination causes the RBC concentration in CSF to be up to 10,000 RBCs/microl.

  2. Development and validation testing of a short nutrition questionnaire to identify dietary risk factors in preschoolers aged 12–36 months

    Directory of Open Access Journals (Sweden)

    Niamh Rice

    2015-06-01

    Full Text Available Background: Although imbalances in dietary intakes can have short and longer term influences on the health of preschool children, few tools exist to quickly and easily identify nutritional risk in otherwise healthy young children. Objectives: To develop and test the validity of a parent-administered questionnaire (NutricheQ as a means of evaluating dietary risk in young children (12–36 months. Design: Following a comprehensive development process and internal reliability assessment, the NutricheQ questionnaire was validated in a cohort of 371 Irish preschool children as part of the National Preschool Nutrition Survey. Dietary risk was rated on a scale ranging from 0 to 22 from 11 questions, with a higher score indicating higher risk. Results: Children with higher NutricheQ scores had significantly (p<0.05 lower mean daily intakes of key nutrients such as iron, zinc, vitamin D, riboflavin, niacin, folate, phosphorous, potassium, carotene, retinol, and dietary fibre. They also had lower (p<0.05 intakes of vegetables, fish and fish dishes, meat and infant/toddler milks and higher intakes of processed foods and non-milk beverages, confectionery, sugars and savoury snack foods indicative of poorer dietary quality. Areas under the curve values of 84.7 and 75.6% were achieved for ‘medium’ and ‘high’ dietary risk when compared with expert risk ratings indicating good consistency between the two methods. Conclusion: NutricheQ is a valid method of quickly assessing dietary quality in preschoolers and in identifying those at increased nutritional risk.In ContextAnalysis of data from national food and nutrition surveys typically identifies shortfalls in dietary intakes or quality of young children. This can relate to intakes of micronutrients such as iron or vitamin D as well as to the balance of macronutrients they consume (e.g. fat or sugar. Alongside this lie concerns regarding overweight and obesity and physical inactivity. This combination of

  3. Reliability of an incremental exercise test to evaluate acute blood lactate, heart rate and body temperature responses in Labrador retrievers.

    Science.gov (United States)

    Ferasin, Luca; Marcora, Samuele

    2009-10-01

    Thirteen healthy Labrador retrievers underwent a 5-stage incremental treadmill exercise test to assess its reliability. Blood lactate (BL), heart rate (HR), and body temperature (BT) were measured at rest, after each stage of exercise, and after a 20-min recovery. Reproducibility was assessed by repeating the test after 7 days. Two-way MANOVAs revealed significant differences between consecutive stages, and between values at rest and after recovery. There was also a significant reduction in physiological strain between the first and second trial (learning effect). Test reliability expressed as typical error (BL = 0.22 mmol/l, HR = 9.81 bpm, BT = 0.22 degrees C), coefficient of variation (BL = 19.3%, HR = 7.9% and BT = 0.6%) and test-retest correlation (BL = 0.89, HR = 0.96, BT = 0.95) was good. Results support test reproducibility although the learning effect needs to be controlled when investigating the exercise-related problems commonly observed in this breed.

  4. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    Science.gov (United States)

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  5. Perceptions of and intentions to use a recently introduced blood-based HIV self-test in France.

    Science.gov (United States)

    Devez, Paul-Emmanuel; Epaulard, Olivier

    2018-06-10

    An estimated 28,000 French people infected with HIV remain undiagnosed, leading to HIV transmission and late-stage HIV infections. An over-the-counter HIV self-test has been available since September 2015. We thus aimed to explore people's perceptions of and intentions to use the test. An anonymous online questionnaire, targeting the general population and men who have sex with men (MSM) was distributed between November 2015 and January 2016. It explored at-risk sexual behavior, perceptions of the HIV self-test, and past and intended future use. A total of 1,082 participants completed ≥90% of the questionnaire (67.1% male, 32.4% female, 0.5% other; mean age 32.8 ± 12 years). 44.8% were MSM. 41.5% declared that they did not always use or make their partner use a condom in the case of penetration with someone other than their usual partner (if applicable). 9.9% had already used the HIV self-test, with this proportion being higher in multivariate analysis for individuals with a monthly income exceeding €1,000 and those declaring to be informed about HIV. 38.5% stated their intention to use the self-test in the coming month or year; in multivariate analysis, this proportion was lower for MSM and higher for those who did not always use or make their partner use a condom in the case of penetration with someone other than their usual partner. The majority (68.4%) underestimated the testing delay to rule out HIV infection. The most frequently cited concerns were that self-test does not test for other sexually transmitted infections (49.5%) and is not free of charge (44.4%), and that users are left alone with the result (41.0%). The HIV self-test was identified as a useful tool by different at-risk populations; it may therefore enhance the number of diagnoses. The test delay must be appropriately communicated to users, while a lower purchase price may increase usage.

  6. Alterations of blood platelet functional tests in whole-body irradiated rabbits

    International Nuclear Information System (INIS)

    Zitko, M.; Pospisil, J.; Klir, P.; Dienstbier, Z.

    1983-01-01

    With a selected spectrum of coagulation tests the functional capacity of thrombocytes was investigated in rabbits exposed to a whole-body irradiation by means of 60 Co radiation with a LD 5/30. A reduced retraction could be proved for postirradiation days 5, 8, 11, 21, 35, and 56. A reduced formation of malondialdehyde could be identified in thrombocytes on the 8th and 21st day after irradiation. No changes could be found in determining adhesiveness, platelet aggregation caused by ADP, and PF 3 A and PF 3 F tests. In the course of additional investigations (coagulation time in unprepared and siliconized glass tubes, thromboelastogram, activated partial thromboplastine time), significant changes of coagulation time could be observed in siliconized glass tubes on the 8th, 11th, 21st, and 56th postirradiation days. (author)

  7. Design of a tablet computer app for facilitation of a molecular blood culture test in clinical microbiology and preliminary usability evaluation

    DEFF Research Database (Denmark)

    Samson, Lasse L.; Pape-Haugaard, Louise; Meltzer, Michelle C.

    2016-01-01

    through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular......-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy...... and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). OBJECTIVE: The objective of the study was to describe the design...

  8. The introduction of anti-HTLV testing of blood donations and the risk of transfusion-transmitted HTLV, UK: 2002-2006.

    Science.gov (United States)

    Davison, K L; Dow, B; Barbara, J A; Hewitt, P E; Eglin, R

    2009-02-01

    The objectives of the study were to describe the introduction of testing blood donations for antibodies to human T-cell lymphotropic virus (anti-HTLV) and to determine the risk of HTLV potentially infectious donations entering the UK blood supply. The rationale for testing was based on (i) evidence of transmission through transfusion in the UK, (ii) the serious nature of HTLV I-associated morbidity and (iii) evidence of infection in UK blood donors. From mid-2002, all blood donations made at UK blood centres were tested in pooled samples using Abbott-Murex HTLV I/II GE 80/81 enzyme immunoassay (EIA). Surveillance data were used to calculate the incidence and prevalence of anti-HTLV and derive estimates of risk. Between August 2002 and December 2006, 106 donations were confirmed positive for anti-HTLV (95 anti-HTLV I and 11 anti-HTLV II). Prevalence was 10-fold higher among donations from new donors than repeat (4.0 and 0.42 per 100 000 donations), and only one repeat donor had evidence of seroconversion. The risk of an HTLV I potentially infectious donation entering the UK blood supply was estimated at 0.11 per million donations (95% confidence interval 0.06 to 0.18). The current very low observed incidence and prevalence among blood donors reflect the very low estimated risk of an HTLV I-positive donation entering the UK blood supply. A change in either the epidemiology of HTLV in UK blood donors or the length of the window period of the test should prompt further review of the risk and a reassessment of anti-HTLV testing in the UK.

  9. Exaggerated Exercise Blood Pressure Response During Treadmill Testing as a Predictor of Future Hypertension in Men: A Longitudinal Study.

    Science.gov (United States)

    Jae, Sae Young; Franklin, Barry A; Choo, Jina; Choi, Yoon-Ho; Fernhall, Bo

    2015-11-01

    The purpose of this study was to evaluate receiver operating characteristic curves to identify optimal cutoff values of exercise systolic blood pressure (SBP) using both peak SBP and relative SBP (peak SBP minus resting SBP) as predictors of future hypertension (HTN). Participants were 3,742 healthy normotensive men who underwent symptom-limited treadmill testing at baseline. Incident HTN was defined as SBP/diastolic blood pressure greater than 140/90 mm Hg and/or diagnosed HTN by a physician. During an average 5-year follow-up, 364 (9.7%) new cases of HTN were observed. The most discriminatory cutoff values for peak SBP and relative SBP for predicting incident HTN were 181 mm Hg (areas under the curve (AUC) = 0.644, sensitivity = 54%, and specificity = 69%) and 52 mm Hg (AUC = 0.549, sensitivity = 64.3%, and specificity = 44.6%), respectively. Participants with peak SBP greater than 181 mm Hg and relative SBP greater than 52 mm Hg had 1.54-fold (95% CI: 1.23-1.93) and 1.44-fold (95% CI: 1.16-1.80) risks of developing HTN after adjusting for potential confounding variables. When these 2 variables were entered simultaneously into the Cox proportional hazards regression model with adjustment for potential confounding variables, only peak SBP (relative risk: 1.39, 95% CI: 1.02-1.89) was a predictor of the development of HTN. The most accurate discriminators for peak and relative SBP during treadmill exercise testing to predict incident HTN were greater than 181 and 52 mm Hg, respectively, in normotensive men. A peak SBP greater than 181 mm Hg during treadmill exercise testing may provide a useful predictor for the development of HTN in clinical practice. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Evaluation of aortic elastic properties in patients with exaggerated systolic blood pressure response to exercise testing.

    Science.gov (United States)

    Kilicaslan, Baris; Eren, Nihan Kahya; Nazlı, Cem

    2015-01-01

    We aimed to evaluate the aortic elastic properties in subjects with hypertensive response to exercise stress test (HRE). Sixty-six patients were divided into two groups (33 patients in HRE group and 33 patients in normotensive group). Baseline demographic characteristics were similar. The mean aortic stiffness index (ASI) was significantly higher (p=0.001) whereas aortic distensibility (AD) was significantly lower (p=0.029) in patients suggesting HRE. The C-reactive protein levels of patients with HRE was higher in the HRE group (p=0.03). AD was significantly correlated with age (r=-0.406, pHRE.

  11. Evaluation of the performance of the OneTouch Select Plus blood glucose test system against ISO 15197:2013.

    Science.gov (United States)

    Setford, Steven; Smith, Antony; McColl, David; Grady, Mike; Koria, Krisna; Cameron, Hilary

    2015-01-01

    Assess laboratory and in-clinic performance of the OneTouch Select(®) Plus test system against ISO 15197:2013 standard for measurement of blood glucose. System performance assessed in laboratory against key patient, environmental and pharmacologic factors. User performance was assessed in clinic by system-naïve lay-users. Healthcare professionals assessed system accuracy on diabetes subjects in clinic. The system demonstrated high levels of performance, meeting ISO 15197:2013 requirements in laboratory testing (precision, linearity, hematocrit, temperature, humidity and altitude). System performance was tested against 28 interferents, with an adverse interfering effect only being recorded for pralidoxime iodide. Clinic user performance results fulfilled ISO 15197:2013 accuracy criteria. Subjects agreed that the color range indicator clearly showed if they were low, in-range or high and helped them better understand glucose results. The system evaluated is accurate and meets all ISO 15197:2013 requirements as per the tests described. The color range indicator helped subjects understand glucose results and supports patients in following healthcare professional recommendations on glucose targets.

  12. [Development of a laboratory test on dried blood spots for facilitating early diagnosis of alpha-1-antitrypsin deficiency].

    Science.gov (United States)

    Balduyck, Malika; Chapuis Cellier, Colette; Roche, Denis; Odou, Marie-Françoise; Joly, Philippe; Madelain, Vincent; Vergne, Anita; Nouadje, Georges; Lafitte, Jean-Jacques; Porchet, Nicole; Beaune, Philippe; Zerimech, Farid

    2014-01-01

    Alpha- 1-antitrypsin (A1AT) deficiency is a hereditary autosomal codominant genetic disorder resulting in low circulating levels of A1AT and leading to lung and/or liver disease. It remains underdiagnosed and only 5 to 10% of PIZZ patients, the most common form of severe A1AT deficiency, would be actually identified in France. Facilitating early diagnosis of A1AT deficiency would allow a better management of this disease; therefore we have developed and standardized in three laboratories involved in this study, a diagnostic test on dried blood spots (DBS) including quantitative A1AT measurement, phenotyping by IEF electrophoresis and, if necessary, genotyping by SERPINA1 gene sequencing. We performed a quantitative assay on 90 DBS samples by immunoturbidimetric or immunonephelometric methods. We demonstrated that both methods were suitable for this type of sampling and the results obtained were highly correlated (R(2)>0.9) between the three laboratories: for a target value of 1.00 g/L, the results obtained from the three laboratories were between 1.00 and 1.02 g/L. Phenotyping and genotyping were performed under redefined operating conditions and adapted to the analysis of DBS samples. The results were comparable with those obtained for venous blood samples. Following this work, it becomes possible to provide pulmonologists with a reliable kit to perform a capillary blood sampling on filter paper which would allow a large-scale screening of A1AT deficiency in the population particularly affected by this genetic condition.

  13. Microbial Contaminants of Cord Blood Units Identified by 16S rRNA Sequencing and by API Test System, and Antibiotic Sensitivity Profiling.

    Directory of Open Access Journals (Sweden)

    Luís França

    Full Text Available Over a period of ten months a total of 5618 cord blood units (CBU were screened for microbial contamination under routine conditions. The antibiotic resistance profile for all isolates was also examined using ATB strips. The detection rate for culture positive units was 7.5%, corresponding to 422 samples.16S rRNA sequence analysis and identification with API test system were used to identify the culturable aerobic, microaerophilic and anaerobic bacteria from CBUs. From these samples we recovered 485 isolates (84 operational taxonomic units, OTUs assigned to the classes Bacteroidia, Actinobacteria, Clostridia, Bacilli, Betaproteobacteria and primarily to the Gammaproteobacteria. Sixty-nine OTUs, corresponding to 447 isolates, showed 16S rRNA sequence similarities above 99.0% with known cultured bacteria. However, 14 OTUs had 16S rRNA sequence similarities between 95 and 99% in support of genus level identification and one OTU with 16S rRNA sequence similarity of 90.3% supporting a family level identification only. The phenotypic identification formed 29 OTUs that could be identified to the species level and 9 OTUs that could be identified to the genus level by API test system. We failed to obtain identification for 14 OTUs, while 32 OTUs comprised organisms producing mixed identifications. Forty-two OTUs covered species not included in the API system databases. The API test system Rapid ID 32 Strep and Rapid ID 32 E showed the highest proportion of identifications to the species level, the lowest ratio of unidentified results and the highest agreement to the results of 16S rRNA assignments. Isolates affiliated to the Bacilli and Bacteroidia showed the highest antibiotic multi-resistance indices and microorganisms of the Clostridia displayed the most antibiotic sensitive phenotypes.

  14. Implementation of immunochemical faecal occult blood test in general practice: a study protocol using a cluster-randomised stepped-wedge design.

    Science.gov (United States)

    Juul, Jakob Søgaard; Bro, Flemming; Hornung, Nete; Andersen, Berit Sanne; Laurberg, Søren; Olesen, Frede; Vedsted, Peter

    2016-07-11

    Colorectal cancer is a common malignancy and a leading cause of cancer-related death. Half of patients with colorectal cancer initially present with non-specific or vague symptoms. In the need for a safe low-cost test, the immunochemical faecal occult blood test (iFOBT) may be part of the evaluation of such patients in primary care. Currently, Danish general practitioners have limited access to this test. The aim of this article is to describe a study that will assess the uptake and clinical use of iFOBT in general practice. Furthermore, it will investigate the diagnostic value and the clinical implications of using iFOBT in general practice on patients presenting with non-alarm symptoms of colorectal cancer. The study uses a cluster-randomised stepped-wedge design and is conducted in the Central Denmark Region among 836 GPs in 381 general practices. The municipalities of the Region and their appertaining general practitioners will be included sequentially in the study during the first 7 months of the 1-year study period. The following intervention has been developed for the study: a mandatory intervention providing all general practitioners with a starting package of 10 iFOBTs, a clinical instruction on iFOBT use in general practice and online information material from the date of inclusion, and an optional intervention consisting of a continuous medical education on colorectal cancer diagnostics and use of iFOBT. This study is among the first and largest trials to investigate the diagnostic use and the clinical value of iFOBT on patients presenting with non-alarm symptoms of colorectal cancer. The findings will be of national and international importance for the future planning of colorectal cancer diagnostics, particularly for 'low-risk-but-not-no-risk' patients with non-alarm symptoms of colorectal cancer. A Trial of the Implementation of iFOBT in General Practice NCT02308384 . Date of registration: 26 November 2014.

  15. Microbial Contaminants of Cord Blood Units Identified by 16S rRNA Sequencing and by API Test System, and Antibiotic Sensitivity Profiling.

    Science.gov (United States)

    França, Luís; Simões, Catarina; Taborda, Marco; Diogo, Catarina; da Costa, Milton S

    2015-01-01

    Over a period of ten months a total of 5618 cord blood units (CBU) were screened for microbial contamination under routine conditions. The antibiotic resistance profile for all isolates was also examined using ATB strips. The detection rate for culture positive units was 7.5%, corresponding to 422 samples.16S rRNA sequence analysis and identification with API test system were used to identify the culturable aerobic, microaerophilic and anaerobic bacteria from CBUs. From these samples we recovered 485 isolates (84 operational taxonomic units, OTUs) assigned to the classes Bacteroidia, Actinobacteria, Clostridia, Bacilli, Betaproteobacteria and primarily to the Gammaproteobacteria. Sixty-nine OTUs, corresponding to 447 isolates, showed 16S rRNA sequence similarities above 99.0% with known cultured bacteria. However, 14 OTUs had 16S rRNA sequence similarities between 95 and 99% in support of genus level identification and one OTU with 16S rRNA sequence similarity of 90.3% supporting a family level identification only. The phenotypic identification formed 29 OTUs that could be identified to the species level and 9 OTUs that could be identified to the genus level by API test system. We failed to obtain identification for 14 OTUs, while 32 OTUs comprised organisms producing mixed identifications. Forty-two OTUs covered species not included in the API system databases. The API test system Rapid ID 32 Strep and Rapid ID 32 E showed the highest proportion of identifications to the species level, the lowest ratio of unidentified results and the highest agreement to the results of 16S rRNA assignments. Isolates affiliated to the Bacilli and Bacteroidia showed the highest antibiotic multi-resistance indices and microorganisms of the Clostridia displayed the most antibiotic sensitive phenotypes.

  16. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  17. The real world of blood glucose point-of-care testing (POCT) system running in China teaching hospital.

    Science.gov (United States)

    Li, Feng-Fei; Xie, Yun; Shi, Bing-Yin; Niu, Min; Guo, Hui; Cao, Yan; Liu, Bing-Li; Yan, Reng-Na; Su, Xiao-Fei; Wu, Jin-Dan; Zhang, Dan-Feng; Chen, Li-Ming; Ma, Jian-Hua

    2018-06-01

     The blood glucose point-of-care testing (POCT) system is important in the decision-making process involving patients suspected of having hypoglycemia. To investigate the real world of the POCT system being used in teaching hospitals in China. The survey was conducted by Hisend Research Group from May 2015 to July 2015 in four teaching hospitals in China. The survey questions were referred to the ISO 15197:2013 standard requirements for the use of the POCT system in a hospital setting. A total of 170 subjects were included from 4 hospitals, which included nursing staff, nurse unit managers, employees from the department of medical instruments, and staff members employed by the clinical laboratories in the Tianjin Metabolism Hospital, Nanjing First Hospital, First Affiliated Hospital of Dalian Medical University, and the First hospital affiliated with the Xi'an Transportation University. The average score for the four hospitals surveyed in this study was 66.6, which varied from 46.1 to 79.7. The main factors influencing the scores were the multiple choices of blood-glucose meters, and the quality control assessment. Our data indicates that the real world use of the POCT system in hospital settings in China needs more closer adherence to a quality management framework.

  18. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, Division of Medicine, London (United Kingdom); Ghanouni, Alex; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Rees, Colin J. [Durham University School of Medicine, Pharmacy and Health, Durham (United Kingdom); Hewitson, Paul [University of Oxford, Health Services Research Unit, Nuffield Department of Population Health, Oxford (United Kingdom); Nickerson, Claire; Wright, Suzanne [Fulwood House, NHS Cancer Screening Programmes, Sheffield (United Kingdom)

    2017-03-15

    To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as complications. CTC and colonoscopy responses were compared using multilevel logistic regression. Of 67,114 subjects identified, 52,805 (79 %) responded. Understanding of test risks was lower for CTC (1712/1970 = 86.9 %) than colonoscopy (48783/50975 = 95.7 %, p < 0.0001). Overall, a slightly greater proportion of screenees found CTC unexpectedly uncomfortable (506/1970 = 25.7 %) than colonoscopy (10,705/50,975 = 21.0 %, p < 0.0001). CTC was tolerated well as a completion procedure for failed colonoscopy (unexpected discomfort; CTC = 26.3 %: colonoscopy = 57.0 %, p < 0.001). Post-procedural pain was equally common (CTC: 288/1970,14.6 %, colonoscopy: 7544/50,975,14.8 %; p = 0.55). Adverse event rates were similar in both groups (CTC: 20/2947 = 1.2 %; colonoscopy: 683/64,312 = 1.1 %), but generally less serious with CTC. Even though CTC was reserved for individuals either unsuitable for or unable to complete colonoscopy, we found only small differences in test-related discomfort. CTC was well tolerated as a completion procedure and was extremely safe. CTC can be delivered across a national screening programme with high patient satisfaction. (orig.)

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  20. Extended safety, immunogenicity and efficacy of a blood-stage malaria vaccine in malian children: 24-month follow-up of a randomized, double-blinded phase 2 trial.

    Directory of Open Access Journals (Sweden)

    Matthew B Laurens

    Full Text Available The FMP2.1/AS02A candidate malaria vaccine was tested in a Phase 2 study in Mali. Based on results from the first eight months of follow-up, the vaccine appeared well-tolerated and immunogenic. It had no significant efficacy based on the primary endpoint, clinical malaria, but marginal efficacy against clinical malaria in secondary analyses, and high allele-specific efficacy. Extended follow-up was conducted to evaluate extended safety, immunogenicity and efficacy.A randomized, double-blinded trial of safety, immunogenicity and efficacy of the candidate Plasmodium falciparum apical membrane antigen 1 (AMA1 vaccine FMP2.1/AS02A was conducted in Bandiagara, Mali. Children aged 1-6 years were randomized in a 1∶1 ratio to receive FMP2.1/AS02A or control rabies vaccine on days 0, 30 and 60. Using active and passive surveillance, clinical malaria and adverse events as well as antibodies against P. falciparum AMA1 were monitored for 24 months after the first vaccination, spanning two malaria seasons.400 children were enrolled. Serious adverse events occurred in nine participants in the FMP2.1/AS02A group and three in the control group; none was considered related to study vaccination. After two years, anti-AMA1 immune responses remained significantly higher in the FMP2.1/AS02A group than in the control group. For the entire 24-month follow-up period, vaccine efficacy was 7.6% (p = 0.51 against first clinical malaria episodes and 9.9% (p = 0.19 against all malaria episodes. For the final 16-month follow-up period, vaccine efficacy was 0.9% (p = 0.98 against all malaria episodes. Allele-specific efficacy seen in the first malaria season did not extend into the second season of follow-up.Allele-specific vaccine efficacy was not sustained in the second malaria season, despite continued high levels of anti-AMA1 antibodies. This study presents an opportunity to evaluate correlates of partial protection against clinical malaria that waned during